TROUBLESHOOTING. Frymaster MF90 Series, Dean MF90 Portable Filters (Prior To May 2002), MF90-172, MF-90/80 LP, MF90-126, MF-90/65, MF-90/160, MF-90/110, MF-90/80, Portable Filters MF90 Series


Add to my manuals
34 Pages

advertisement

TROUBLESHOOTING. Frymaster MF90 Series, Dean MF90 Portable Filters (Prior To May 2002), MF90-172, MF-90/80 LP, MF90-126, MF-90/65, MF-90/160, MF-90/110, MF-90/80, Portable Filters MF90 Series | Manualzz

6.3 Wiring Diagrams

MF90 Filter Wiring (AU)

PUMP REVERSING

SWITCH

OFF/ON HEATER SWITCH

(OPTIONAL)

OPTIONAL

BLK

CB

7 AMP

BLK 1

BLK 4

BLK 8

BLK 5

RED

2 AMP

FUSE

TIMER

SWITCH

SWITCH HOUSING

INDICATOR

LIGHT

BLK

GRN

WHT

T5

T8

T1

T4

MOTOR

TERMINAL BOX

BLK 5

BLK 8

BLK 4

BLK 1

WHT

RED

Junction

Box

OPTIONAL

OPTIONAL

WHT

Suction Sump

Heater One Way Valve

Heater

MF90 Filter Wiring (U)

PUMP

SWITCH

BLK

CB 7 AMP

P1

P2

T3

T5

T2

T4

T8

BLK

BLK

WHT

TIMER

SWITCH

BLK

GRN

WHT

POWER CORD

AWG 16-3 SJT

6-6