abtthgde.book Page i Tuesday, June 23, 1998 10:29 AM
®
7600 Fast Ethernet Card
User Guide
http://www.3com.com/
Part No. DUA7600-0AAA01
Published November 1997
P
r
abtthgde.book Page ii Tuesday, June 23, 1998 10:29 AM
3Com Corporation
Q
5400 Bayfront Plaza
Q
Santa Clara, California
Q
95052-8145
© 3Com Corporation, 1996. All rights reserved. No part of this documentation may be reproduced in any form
or by any means or used to make any derivative work (such as translation, transformation, or adaptation)
without permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time
to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty of any kind, either implied or expressed,
including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
3Com may make improvements or changes in the product(s) and/or the program(s) described in this
documentation at any time.
UNITED STATES GOVERNMENT LEGENDS:
If you are a United States government agency, then this documentation and the software described herein are
provided to you subject to the following restricted rights:
For units of the Department of Defense:
Restricted Rights Legend: Use, duplication or disclosure by the Government is subject to restrictions as set forth
in subparagraph (c) (1) (ii) for restricted Rights in Technical Data and Computer Software clause at 48 C.F.R.
52.227-7013. 3Com Corporation, 5400 Bayfront Plaza, Santa Clara, California 95052-8145.
For civilian agencies:
Restricted Rights Legend: Use, reproduction or disclosure is subject to restrictions set forth in subparagraph (a)
through (d) of the Commercial Computer Software - Restricted Rights Clause at 48 C.F.R. 52.227-19 and the
limitations set forth in 3Com Corporation’s standard commercial agreement for the software. Unpublished
rights reserved under the copyright laws of the United States.
If there is any software on removable media described in this documentation, it is furnished under a license
agreement included with the product as a separate document, in the hard copy documentation, or on the
removable media in a directory file named LICENSE.TXT. If you are unable to locate a copy, please contact
3Com and a copy will be provided to you.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may
not be registered in other countries.
3Com, Boundary Routing, CardFacts, LanScanner, LinkBuilder, NETBuilder, NETBuilder II, NetFacts, Parallel
Tasking, ViewBuilder, EtherDisk, EtherLink, EtherLink Plus, EtherLink II, TokenLink, TokenLink Plus, and
TokenDisk are registered trademarks of 3Com Corporation. 3TECH, CacheCard, FDDILink, FMS, NetProbe,
SmartAgent, Star-Tek, and Transcend are trademarks of 3Com Corporation. 3ComFacts, Ask3Com, and
CardBoard are service marks of 3Com Corporation.
CompuServe is a registered trademark of CompuServe, Inc.
Other brand and product names may be registered trademarks or trademarks of their respective holders.
Guide written by Joel Harband. Edited by Patricia Carmel. Technical illustration by Yael Scherzer. Supervised by
Marvin Rabinovitch. Production by 3Com.
ii
abtthgde.book Page i Tuesday, June 23, 1998 10:29 AM
CONTENTS
ABOUT THIS GUIDE
Who Should Use This Guide 1
How to Use This Guide 1
Conventions 2
Informational and Warning Conventions
Typographical Conventions 2
Related Manuals 2
Documentation Road Map 3
1
OVERVIEW OF THE 7600 CARD
About the 7600 Card 1-1
A Look at the 7600 Card 1-1
Port Configurations 1-1
Connectors 1-3
LEDs 1-3
7600 Card Capabilities 1-3
7600 Card Benefits 1-4
Ethernet-switching Features 1-4
Virtual LANs 1-4
Traffic Management 1-5
Device Management 1-5
Typical Applications of the 7600 Card
Fast Ethernet Backbone 1-5
Server Farm 1-7
2
2
1-5
INSTALLATION AND POWER-UP
Safety Precautions 2-1
Mesures de sécurité 2-2
Vorsichtsmaßnahmen 2-3
Installing and Removing the 7600 Card Modules
2-4
i
abtthgde.book Page ii Tuesday, June 23, 1998 10:29 AM
Installing the 7600 Card Module 2-4
Removing the 7600 Card Module 2-4
Installing a Fast Ethernet Physical Module
Connecting to Network Devices 2-5
Connecting to a Local Management Terminal
7600 Card System States 2-7
System States and LEDs 2-7
Power-Up 2-8
Power-on Self-Test 2-8
Normal operation 2-8
Fast Ethernet Status Indicators 2-8
3
FAST SETUP
Rapid Configuration 3-1
CELLplex 7000 Integrated Fast Setup 3-2
Setup Modes 3-2
Setup Procedure Sections 3-4
Navigation Aids 3-4
Integrated Fast Setup Operation 3-5
Example Dialog 3-6
Multi-context Fast Setup 3-10
Setup Procedure Sections 3-10
Editing Guidelines 3-11
Navigation Aids 3-11
Multi-context Setup Operation 3-12
Sample Screen Dialog 3-12
4
LOCAL MANAGEMENT BASICS
Management Capabilities 4-1
Menu Hierarchy 4-1
Main Menu 4-2
Selecting Menu Options 4-3
Direct Access to Submenus 4-4
Parameter Entry 4-4
Quick Key Functions 4-4
Menu Index 4-6
ii
2-5
2-6
abtthgde.book Page iii Tuesday, June 23, 1998 10:29 AM
5
CONFIGURING VIRTUAL LANS
Display Current Bridge Configuration 5-1
Attach Fast Ethernet Port to Bridge 5-2
Attach Internal ATM Port to Bridge 5-3
6
FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Fast Ethernet Port Attributes and Statistics 6-2
Disable a Fast Ethernet Port 6-5
Display Broadcast Throttling Attributes 6-5
Update Broadcast Threshold 6-6
Enable/Disable Broadcast Throttling 6-6
Update Fast Ethernet Port 6-7
Bridge Attributes and Statistics 6-8
Update Bridge-agingtime 6-10
Bridge-port Attributes and Statistics 6-10
Display All Entries in Forwarding Database 6-12
Display Learned Entries in Forwarding Database 6-14
Display Static Entries in Forwarding Database 6-15
Enter or Modify a Static Address in FDB 6-19
Block a Static Address 6-19
Remove a Static Address from FDB 6-20
Display STP Enable Status 6-21
Disable STP on Bridge 6-21
Display Bridge STP Attributes 6-22
Update Bridge-wide STP Parameters 6-24
Update Bridge-priority 6-24
Update Bridge-max-age 6-24
Update Bridge-hello-time 6-24
Update Bridge-forwarddelay 6-25
Display Bridge-port STP Attributes 6-26
Disable Bridge-port 6-27
Update Bridge-port STP parameters 6-27
Update Bridge-portpriority 6-27
Update Bridge-path-cost 6-28
iii
abtthgde.book Page iv Tuesday, June 23, 1998 10:29 AM
7
MANAGING ATM RESOURCES
Display ATM Port Attributes and Statistics 7-2
Display Bridge ATM address 7-3
Update Bridge ATM Address 7-4
Display TM Configuration 7-5
Enable TM 7-6
Display TM Clients 7-6
Add TM Client 7-8
Remove TM Client 7-8
Update UNI Version 7-9
Enable/Disable ATM Port Admin Status 7-9
8
MANAGING LAN EMULATION CLIENTS
Display LEC Statistics 8-2
Display Current LEC Configuration 8-4
Update LECS Address 8-6
Update ELAN Name 8-6
Update LES Address 8-7
Enable LECS Address via ILMI 8-7
Display LEC Operational Parameters 8-8
Update LEC Operational Parameters 8-9
Control-timeout 8-9
VCC-timeout-period 8-10
Aging-time 8-10
Forward-delay-time 8-11
Topology-changeflag 8-11
Expected LE_ARP response-time 8-11
Flush-timeout 8-12
Path-switchingdelay 8-12
Connectioncompletion-timer 8-13
Display LEC Control-frame Statistics 8-14
Reset LEC Control-frame Statistics 8-17
Update Unknown Unicast-floodMode 8-17
iv
abtthgde.book Page v Tuesday, June 23, 1998 10:29 AM
9
SETTING NETWORK PARAMETERS
Display Current IP Configuration 9-2
Update IP Address 9-2
Update Default Gateway 9-3
Update Subnet Mask 9-4
Display SNMP Configuration 9-4
Update NMS IP Address 9-5
10
MANAGING SYSTEM FUNCTIONS
Display Software Version 10-2
Display Software Download Status 10-3
Download Software from Network 10-3
Erase Software from Flash 10-4
Download Software from Local 10-4
Display Hardware Configuration 10-5
Set System Configuration Mode 10-6
Set Store-andForward Mode 10-7
Display Timeout Parameters 10-8
Display Timeout Delays 10-11
Update Hardware Timeout Delay 10-11
Update Software Timeout Delay 10-12
Reset Flash Memory 10-12
Update Read-access Password 10-13
Update Write-access Password 10-13
Update Admin-access Password 10-14
Enable/Disable Event Messages 10-14
Reset and Reboot 10-15
11
ETHERNET LANS AND BRIDGES IN THE 7600 CARD
Overview of Ethernet 11-1
Fast Ethernet 11-2
Capabilities 11-2
Cabling 11-4
Fast Ethernet Ports 11-5
Disabling Ports 11-5
v
abtthgde.book Page vi Tuesday, June 23, 1998 10:29 AM
Monitoring Ports 11-5
Transparent Bridges 11-6
Store-and-Forward 11-6
Forwarding Database 11-7
Learning Station Addresses 11-7
Static Addresses 11-8
Spanning Tree Protocol 11-8
Re-configuring the Spanning Tree 11-10
Disabling the STP 11-10
Management Bridge Parameters 11-11
Bridged-LAN Environments in the 7600 Card 11-11
Local Bridged-LAN Environment 11-12
Connection to the ATM Network 11-12
12
ATM, LAN EMULATION, AND VIRTUAL LANS
ATM Overview 12-1
ATM Basics 12-2
Cell Switching 12-2
Virtual Channels 12-3
Virtual Channel Connection 12-3
Virtual Path Connection 12-3
Permanent Virtual Channels 12-3
Switched Virtual Channels 12-4
Interim Local Management Interface (ILMI) 12-4
ILMI Management Information Base (MIB) 12-4
ATM Address Registration 12-5
LAN Emulation Overview 12-5
Emulated LAN Components 12-5
LAN Emulation Client 12-6
LAN Emulation Server 12-6
Broadcast and Unknown Server (BUS) 12-6
LAN Emulation Configuration Server (LECS) 12-7
Emulated LAN Connections 12-7
Control VCCs 12-7
LEC Control Frame Statistics Display 12-8
Data VCCs 12-8
LEC Configuration and Status Information 12-9
vi
abtthgde.book Page vii Tuesday, June 23, 1998 10:29 AM
Bridges in the 7600 Card 12-10
Bridge Forwarding Database 12-12
Address Resolution 12-12
Learning Addresses 12-13
LES Address Registration in the 7600 Card 12-13
Aging in the LE_ARP Cache 12-14
Bridge Frame Forwarding Logic 12-14
Data Transmission over an ELAN 12-15
Unicast Frames 12-15
Unknown Unicast Frames 12-15
Multicast Frames 12-16
Control Information on Data VCs 12-16
LEC Statistics 12-16
LEC Parameters 12-16
Virtual LANs Overview 12-17
Virtual LANs in the 7600 Card 12-18
Connecting Local Segments to a vLAN 12-18
Virtual LANs for three Workgroups 12-21
13
TRAFFIC MANAGEMENT IN THE ATM NETWORK
Overview 13-1
Flow Control Model for ABR 13-2
Traffic Management Concepts 13-3
Explicit Forward Congestion Indication 13-3
Cell Loss Priority 13-3
Implicit Rate Control 13-3
Explicit Rate Control 13-4
Traffic and Congestion Control Functions 13-4
Traffic Rates Shaping in the 7600 Card 13-5
RM Cell Usage 13-5
Flow Rate Adjustment 13-6
Transmission Rate Profiles 13-6
Dual-Rate Mechanism 13-6
Static and Dynamic TM 13-6
TM Remote Client Database 13-6
Traffic Management in the Network 13-7
vii
abtthgde.book Page viii Tuesday, June 23, 1998 10:29 AM
14
DEVICE MANAGEMENT
User Interfaces and Protocols 14-1
In-Band & Out-of-Band Management 14-2
7600 Card Management 14-3
Local Management (LM) 14-3
Simple Network Management Protocol (SNMP)
Virtual Terminal Protocols 14-7
15
14-4
SYSTEM MODES, ATTRIBUTES, AND TUNING
Forwarding Modes 15-1
Timeout Tuning 15-2
Console Passwords 15-3
A
TECHNICAL SUPPORT
On-Line Technical Services A-1
3Com Bulletin Board Service A-1
Ask3Com on CompuServe A-2
3ComFacts Automated Fax Service A-2
Telephone Support A-2
Support from 3Com A-3
Support from Your Network Supplier A-3
Returning Products for Repair A-4
B
TROUBLESHOOTING
Solving Common Problems B-1
Terminal Does Not Show Anything B-1
ACT LED Not Blinking B-1
Ethernet Forwarding Failures (Fx port) B-1
Related Diagnostic Procedures B-2
Cleaning Dirty Fiber Optic Cables B-2
C
7600 FAST ETHERNET CARD SPECIFICATIONS
Physical C-1
Interfaces C-1
Fast Ethernet Switching
viii
C-1
abtthgde.book Page ix Tuesday, June 23, 1998 10:29 AM
Environmental C-2
Indicators C-2
Management C-2
Standards Compliance C-3
Safety C-3
Electromagnetic Emissions (Agency Certifications)
Communications Protocols C-3
Management Protocols C-3
C-3
GLOSSARY
ix
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
Who Should Use This Guide
1
ABOUT THIS GUIDE
The 7600 Fast Ethernet Card User Guide provides the information
required to understand how the 7600 Card works in ATM and Ethernet
environments.
If the information in the Release Notes shipped with your product differs
from the information in this guide, follow the Release Notes.
Who Should Use
This Guide
This guide is intended for the System or Network Administrator
responsible for configuring and managing the 7600 Card. It assumes a
working knowledge of Local Area Network (LAN) operation and
communication protocols.
How to Use This
Guide
The following table shows where to find specific information.
If you are looking for information about:
Turn to:
An overview of the 7600 Card key features and technologies.
Chapter 1
Installation and Power-Up of the 7600 Card
Chapter 2
Setting up the 7600 Card
Chapter 3
Local Management Basics
Chapter 4
Configuring Virtual LANs
Chapter 5
Ethernet and Bridge Management Tasks
Chapter 6
Managing ATM Resources
Chapter 7
Managing LAN Emulation Clients
Chapter 8
Setting Network Parameters
Chapter 9
Managing System Functions
Chapter 10
An overview of Ethernet LANs and Bridges
Chapter 11
An overview of ATM, LAN Emulation and Virtual LANs.
Chapter 12
An overview of Traffic Management.
Chapter 13
An overview of Device Management
Chapter 14
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
2
ABOUT THIS GUIDE
If you are looking for information about: (continued)
Turn to:
An overview of system Modes, Attributes and Tuning
Chapter 15
Technical support available for the 7600 Card
Appendix A
Troubleshooting the 7600 Card
Appendix B
Specifications of the 7600 Card
Appendix C
Conventions
Tables 1 and 2 list conventions used throughout this guide.
Informational and
Warning Conventions
Table 1 lists informational and warning conventions.
Table 1 Notice Icons
Icon
Type
Description
Information Note Information notes call attention to important features
or instructions.
Typographical
Conventions
Caution
Cautions alert you to personal safety risk, system
damage, or loss of data.
Warning
Warnings alert you to the risk of severe personal injury.
Table 2 lists the typographical conventions used by this guide.
Table 2 Typographical Conventions
Related Manuals
Type
Description
Courier
Used for sample displays to show what appears on your terminal
screen.
Table 3 lists the 7600 Card documentation set and other related manuals.
Table 3 7600 Card Documentation and Related Manuals
Manual Name
3COM Part No.
7600 Fast Ethernet Card User Guide
7600 Fast Ethernet Card System Release Notes
DUA7600-0AAA01
CELLplex 7000 Operation Guide
DUA3700-0CAA02
CELLplex 7000 Administration Guide
DUA3700-0CAA02
CELLplex 7000 Installation and Setup Guide
DUA3700-0BAA02
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Related Manuals
3
Table 3 7600 Card Documentation and Related Manuals (continued)
Documentation Road
Map
Manual Name
3COM Part No.
Transcend Enterprise Manager, ATM and VLAN
Management
DUA2785-0NAA03
The Documentation Road Map in Table 4 helps you locate specific
information in the 7600 Card documentation set.
.
Table 4 7600 Card Documentation Road Map
If you want to...
Read...
Learn about new features or bug fixes in the
7600 Card software
Release Notes
Learn about changes to the 7600 Card’s
documentation
Release Notes
Get an overview of the 7600 Card, including
system components
User Guide
Learn about various configurations in which you
can install your 7600 Card
User Guide
Learn about how you administer and manage the
7600 Card
User Guide
Learn about ATM and how it is implemented in the User Guide
7600 module
Learn about Ethernet Switching and how it is
implemented in the 7600 Card
User Guide
Learn about LAN Emulation and how it is
implemented in the 7600 Card
User Guide
Find out what type of configuration tasks you can
perform on the 7600 Card
User Guide
Quickly set up your 7600 Card for management
access
User Guide
Perform configuration or administration tasks using User Guide
the Administration Console
Get assistance
Technical Support Appendix in
any guide
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
1
OVERVIEW OF THE 7600 CARD
This chapter provides an overview of the 7600 Fast Ethernet Interface
Card and its major features and components.
About the 7600
Card
A Look at the 7600
Card
Port Configurations
The 7600 Card provides up to 16 Fast Ethernet fiber optic or copper ports
and is based on multiple ASIC ZipChip technology. Featuring a full or half
duplex capability, the 7600 includes fully modular physical interfaces
which can be upgraded in the field with a mixture of 100BASEFx and Tx
ports.
The 7600’s front panel includes:
Q
16 Fast Ethernet ports
Q
LED indicators
Q
Port position indicators
The 7600 Card provides a base card comprising eight Fast Ethernet
100BASE-Fx (fiber) or 100BASE-Tx (copper) connectors and four optional
Fast Ethernet physical modules, which can be installed in configurations
of two 100BASE-Fx or 100BASE-Tx ports per module.
Fast Ethernet ports on the base card are numbered 1 to 8, left to right;
Fast Ethernet ports on the upper layer physical modules are numbered 9
to 16, left to right. Figure 1-1 shows the front panel of the 7600 Card
with the maximum number of Fast Ethernet physical modules installed.
Figure 1-2 shows the front panel of the 7600 Card with only the base
configuration installed.
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
1-2
CHAPTER 1: OVERVIEW OF THE 7600 CARD
Figure 1-1 Front Panel of the 7600 Card with full configuration
Figure 1-2 Base card with plates covering ports 9-16 (optional modules)
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
7600 Card Capabilities
Connectors
1-3
Fast Ethernet 100BASE-Fx interface connections are made through SC
connectors; Fast Ethernet 100BASE-Tx interface connections are made
through RJ-45 connectors. These are shown in Figure 1-3 and Figure 1-4
respectively.
Figure 1-3 Physical module with SC connector for fiber ports
Figure 1-4 Physical module with RJ-45 connector for copper ports
LEDs
7600 Card
Capabilities
LEDs at the left side of the front panel indicate the operational status of
the 7600 Card and each of the Fast Ethernet ports.
The 7600 Card, an integrated 16-port Fast Ethernet card, is part of a
series of Ethernet interface cards developed for the CELLplex 7000 ATM
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
1-4
CHAPTER 1: OVERVIEW OF THE 7600 CARD
switch and is similar in functionality to the 7200 Ethernet/ATM Interface
Card.
7600 Card Benefits
Ethernet-switching
Features
Virtual LANs
Fast Ethernet switching works with Virtual LANs and management to
ensure that information flow does not cross Virtual LAN boundaries. The
7600 Card provides the following benefits:
Q
Boosts performance for individual workstations where bandwidth
demands are high.
Q
Establishes Virtual LANs across the enterprise.
Q
Enables Fast Ethernet backbones to downlink from the Super-Stack II
Switch 1000 on the desktop to the Fast Ethernet in the basement (see
Figure 1-5).
Q
Relieves traffic bottlenecks for workgroup servers and server farms
(see Figure 1-6).
The 7600 Card, which implements Fast Ethernet standards 802.3u and
Bridging standard 802.1d, includes the following key features:
Q
Auto-sensing full duplex/half duplex, supported by the TX interface
Q
Auto-sensing 10/100 Mbps, supported by the TX interface
Q
Rate-based flow control
Q
Full rate multicast support
Q
Address table capacity of up to 32k entries
Q
Full rate forward/filter
Q
IEEE 802.1d Spanning Tree Protocol (STP) support
Q
Virtual LAN support
Q
LAN Emulation Client (LEC) support
Q
Local management via the CELLplex 7000’s RS-232 port
Q
Congestion management
Q
MIBs supported: MIB2, Bridge MIB, AToM MIB, LEC MIB, RMON MIB,
Interface Evolution MIB, NCDCHASS MIB (private)
Virtual LANs are Ethernet segments grouped together to form a common
broadcast domain across the enterprise. Using the 7600 Card, you can
establish Virtual LANs using ATM and LAN Emulation. Segments in a
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Typical Applications of the 7600 Card
1-5
Virtual LAN can incorporate both legacy LANs and ATM devices. Virtual
LANs allow the establishment of logical workgroups, independent of
physical connections, to achieve more flexible management. Using this
feature, you can dynamically set up and manage workgroups composed
of members from various departments or business units around the
enterprise, regardless of their physical location.
Traffic Management
Traffic Management optimizes use of system resources to ensure
optimum control of traffic and congestion. The 7600 Card makes use of
the ATM Forum Traffic Management standard to expedite traffic to
Ethernet workgroup servers and server clusters by providing dynamic
traffic rate shaping.
Device Management
The 7600 Card can be managed in a number of ways:
Q
LMA terminal connected by serial line to the local management
terminal port on the host CELLplex 7000 switch.
Q
Telnet over the network via IP connectivity to host CELLplex 7000
switch from a PC or a work station connected in-band.
Q
Transcend Enterprise Manager (or any other SNMP-based network
management application) connected over the network to the 7600
Card’s IP.
For more information see “Connecting to a Local Management Terminal”
on page 2-6 and Chapter 14.
Typical Applications
of the 7600 Card
The 7600 Card can be used to advantage in many different locations and
configurations. See the following two examples:
Fast Ethernet
Backbone
Figure 1-5 shows the 7600 Card used in a Fast Ethernet backbone where
the host CELLplex 7000 is located in the data center and each floor is
served by a Super-Stack II Switch 1000. The Fast Ethernet downlink from
the Switch 1000 units connect to the Fast Ethernet ports of the 7600
Card. Each 7600 Card can handle 16 Switch 1000 units.
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
1-6
CHAPTER 1: OVERVIEW OF THE 7600 CARD
Figure 1-5 Fast Ethernet backbone
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Typical Applications of the 7600 Card
Server Farm
1-7
Figure 1-6 shows the 7600 Card used in a “server farm”. Up to 16 servers
can be connected through Fast Ethernet links to the 7600 Card. The host
CELLplex 7000 is shown connected through ATM links to the Super-Stack
II Switch 2700 units located on different floors.
Figure 1-6 Server farm
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
STARTING UP
I
Chapter 2
Installation and Power-up
Chapter 3
Fast Setup
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
2
INSTALLATION AND POWER-UP
This chapter describes the installation of the 7600 Card in a CELLplex
7000 ATM switch, the physical connections to the 7600 Card, and the
7600 Card power-up procedure. It also includes a summary of system
states.
The following topics are discussed:
Q
Safety Precautions
Q
Installing the 7600 Card
Q
Installing a Fast Ethernet physical module
Q
Connecting to network devices
Q
Connecting to a local management terminal
Q
7600 Card System States
Q
Power-up
Safety Precautions
All servicing should be undertaken ONLY by qualified service personnel.
Read the following safety precautions carefully to reduce the risk of
electric shock and fire.
3Com recommends that you use a wrist strap connected to a proper
ground when handling replacement parts. This helps prevent the module
from being damaged by electrostatic discharge. Additionally, when not in
use, the module should be stored in an antistatic bag.
DO NOT insert any metal objects, such as a screwdriver or a ring on a
finger, in the open slot when replacing a module while the system is
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
2-2
CHAPTER 2: INSTALLATION AND POWER-UP
powered on, This could cause burns or other bodily harm, as well as
system damage.
DO NOT operate the unit in a location where the maximum ambient
temperature exceeds 40 degrees C.
DO NOT plug in, turn on or attempt to operate an obviously damaged
unit.
Ensure that the chassis ventilation openings in the unit are NOT
BLOCKED.
Mesures de sécurité
Le service après-vente ne devra être effectué que par un
personnel qualifié.
Lire attentivement les mesures de sécurité afin de réduire les risques
d'électrocution et d'incendie.«
Lors de la manipulation des pièces de rechange, 3 Com recommande de
toujours utiliser une bande attachée au poignet et reliée à la terre. Cela
aidera à éviter que la pièce ne soit endommagée par une décharge
électrostatique. De plus, lorsqu'il n'est pas utilisé, le module doit être
conservé dans un emballage antistatique.
Si le système est alimenté lors de l'installation ou du remplacement d'un
module, ne jamais insérer d'objet métallique tel qu'un tourne-vis ou un
doigt portant un bijou dans la fente. Cela est susceptible de provoquer
brûlures ou autres dommages corporels, et d'endommager le système.
Ne pas faire fonctionner l'unité dans un endroit où la température
ambiante maximale dépasse 40 degrés C.
S'assurer que les orifices de la ventilation du chassis de l'unité ne sont pas
obstruées.
Ne jamais essayer de brancher, allumer ou faire fonctionner une unité
apparemment endommagée.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Vorsichtsmaßnahmen
2-3
Vorsichtsmaßnahm
en
Jede Wartung sollte NUR von befugtem
Wartungspersonal durchgeführt werden.
Lesen Sie die folgenden Vorsichtsmaßnahmen sorgfältig, um das Risiko
von Stromschlag oder Brandgefahr zu vermeiden.
Wenn Sie Ersatzteile handhaben, benutzen Sie immer ein Band am
Handgelenk, daß gut geerdet ist. Das hilft vermeiden, daß das
Ersatzteil durch elektrostatische Entladung beschädigt wird. Darüber
hinaus sollte ein Modul, wenn nicht in Gebrauch, in einem
antistatischen Beutel aufbewahrt werden.
Steht das System unter Strom, wenn sie ein Modul installieren oder
auswechseln, führen Sie keine Metallgegenstände, wie einen
Schraubenzieher oder einen Finger mit Schmuck in den offenen Schlitz
ein. Das könnte zu Verbrennungen oder anderen Körperschäden
führen, sowie auch zu Schäden am System.
Nehmen Sie das Gerät NICHT in Betrieb, falls die Temperatur der
Umgebung 40 Grad C übersteigt.
Gehen Sie sicher, daß die Lüftungsöffnungen am Gehäuse NICHT
BLOCKIERT sind.
Eine offensichtlich schadhafte Einheit sollte weder angeschlossen,
eingeschaltet noch in Betrieb genommen werden.
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
2-4
CHAPTER 2: INSTALLATION AND POWER-UP
Installing and
Removing the
7600 Card Modules
Installing the 7600
Card Module
The following section discusses how to install and remove the 7600 Card
and its optional modules.
To install the 7600 Card module into the CELLplex 7000 chassis, perform
the following steps:
1 Pull the ejector tabs on each side of the front panel to their outermost
position and orient the 7600 Card in front of the selected slot of the
CELLplex 7000.
2 Place the module between the runners of the selected slot and slide it
into the CELLplex 7000 chassis until it reaches the backplane and can go
no further.
While sliding the 7600 Card into chassis, make sure that the loose hex
spacers on the card do not interfere with inserting the module.
3 Make sure the ejector tabs are still in their outermost position and give
the module a firm push to ensure that the card has fit snugly into the
connectors on the backplane.
4 Push the ejector tabs to their innermost position to lock the module in
place.
You may have to apply pressure on the tabs in order to ensure that the
board is firmly in place in the connectors in the backplane. An audible
click indicates that the connectors have engaged.
5 Pull the ejector tabs to the middle position.
6 Tighten the module’s securing screws on the front panel.
Removing the 7600
Card Module
To remove the 7600 Card from the CELLplex 7000 chassis perform the
following steps:
1 Release the screws on the front panel.
2 Pull the ejector tabs to their outermost position and carefully slide the
module out.
The 7600 Card module can be inserted into or removed from the chassis
of the CELLplex 7000 ATM switch while the switch is powered up
(i.e., hot-swapped).
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Connecting to Network Devices
Installing a Fast
Ethernet Physical
Module
2-5
You can install up to four, 2-port Fast Ethernet physical modules on to the
7600 Card. Each module can be configured for either 100BASE-Fx or
100BASE-Tx connections.
The 7600 Card is supplied with 12 male/female spacers with which to
attach the physical modules.
To install a physical module on to the 7600 Card module, perform the
following steps:
1 Remove the 7600 Card module from the CELLplex 7000 chassis if it is
already installed.
2 Remove the plate covering the cutout for the connector from the front
panel.
3 Hold the physical module at an angle behind the front panel so the
connectors on the physical module are aligned with the unoccupied
cutout on the front panel, and insert the connector into the cutout. (See
1 in Figure 2-1).
Figure 2-1 Installing a Fast Ethernet physical module
4 Lower the card on to the spacers located on the 7600 Card, making sure
that the screws on the physical module fit into the spacers. (See 2 in
Figure 2-1).
5 Tighten the screws to fix the module in place.
Connecting to
Network Devices
Fast Ethernet TX ports (RJ-45) use CAT-5 STP (shielded twisted pair); Fast
Ethernet FX ports (SC connectors) use multi-mode, fiber cable. The
connectors TP or TX are configured as MDIX, suitable for direct
connection to a workstation or other DTE, using a normal,
straight-through twisted-pair cable. To connect a 7600 Card to another
10/100BASET switch, you can use either a crossover cable or, if
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
2-6
CHAPTER 2: INSTALLATION AND POWER-UP
applicable, set the port on the connected device to MDI and use a
straight-through cable.
Connecting to a
Local Management
Terminal
The following section describes the physical connection of the 7600 Card
to a local terminal via the CELLplex 7000 switch.
All interface cards in the CELLplex 7000 can be managed via the serial
port, using an RS-232 connection through a female 9-pin D-type
connector.
During installation, use a shielded cable for the management connector.
The CELLplex 7000 switch module’s serial port is set to function with the
connected equipment according to the following values:
Table 2-1 Serial Port Settings
Serial Port Setting
Value
Baud Rate
19200
Character Size
8 Bit
Stop Bit
1
Parity
No Parity
Flow Control
Xon/Xoff
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
7600 Card System States
7600 Card System
States
System States and
LEDs
2-7
This section describes the different system states of the 7600 Card and
how they are indicated on the LED display.
The following Table 2-2 lists the system states of the 7600 Card module
in the first column. The state in which the 7600 Card is currently
operating is displayed by the system status LEDs. Referring to Figure 2-2,
these are the three LEDs: P(ower), F(ail), and A(ctive) under the label
“SYS” on the left side of the LED panel. Table 2-2 shows the correlation
between the current system state and SYS LEDs.
Table 2-2 7600 Card System States
SYS LED
System State
Power (green)
Fail (red)
Active (orange)
Power-up
On
Random
Random
Normal operation
On
Off
Flashing
Hardware fault
On
On
Off
Software fault
On
Off
Not flashing
No power to unit
Off
Off
Off
Figure 2-2 7600 Card LEDs
Table 2-3 also provides information about the system states but is
organized by system status LED. The meaning of each SYS LED mode is
described.
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
2-8
CHAPTER 2: INSTALLATION AND POWER-UP
Table 2-3 System Status LEDs
SYS LED
Mode
Meaning and User Action
Power
(green)
On
Unit is functioning properly.
Off
If the unit is not functioning, contact your supplier.
Fail
(red)
On
A hardware fault in the unit has been detected. If
possible, extract the 7600 Card from the chassis and
plug it back in. If this fails to rectify the problem, contact
your supplier.
Off
No hardware fault detected.
Active
(orange)
Power-Up
Power-on Self-Test
Flashing
Normal operation.
Steady
A software problem has been detected. If possible,
extract the 7600 Card from the chassis and plug it back
in. If this fails to rectify the problem, contact your
supplier.
When the 7600 Card is powered-up, it automatically begins the
power-up phase and initiates the Power-On Self-Test.
The 7600 Card’s automatic Power-On Self-Test verifies that every
component in the system is fully functional.
While the Power-On Self-Test is in progress, the Power LED is green.
When the Power-On Self-Test is completed, the Power LED maintains a
steady green and the Active orange LED flashes to indicate that the unit is
functioning. If the unit is not functioning, the light goes off; in such a
case, contact your supplier.
The Power-On Self-Test should take a maximum of sixty seconds.
Normal operation
Fast Ethernet Status
Indicators
After completion of the Power-on Test, the 7600 begins normal operation
automatically. The LEDs continue to display the system status of the 7600
Card module as well as the individual data connections of each Fast
Ethernet LED display.
Referring to Figure 2-2, each of the 16 multi-color LEDs corresponds to
the 16 Fast Ethernet ports in each connector on the front panel,
according to the same geometrical configuration. Each multi-color LED
can appear in one of three states: green, orange or off.
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
Normal operation
2-9
The purpose of the Fast Ethernet LEDs is to display the connection status
and traffic status on the corresponding Fast Ethernet port. These are
displayed according to the following table:
Table 2-4 Fast Ethernet Port LEDs
LED (Color)
Meaning
Link status (Green)
The port is connected.
Packet status (*Orange)
There is active traffic on the port.
Link and Packet (Green and Orange) The port is connected and traffic is flowing
into the port.
Off
The port is not connected.
* The orange light intensity indicates the traffic percentage
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
3
FAST SETUP
This chapter describes two methods of configuring the 7600 Card which
allow it to function in the network almost immediately.
The following methods are discussed:
Rapid
Configuration
Q
Integrated Fast Setup of the host CELLplex 7000
Q
Multi-context Fast Setup of the 7600 Card
After the 7600 Card has been physically connected to your site network
devices and power has been applied, you must make the logical
connections that enable the 7600 Card and its attached devices to
function as a networked whole.
There are two ways to perform a “Fast Setup” that will enable the 7600
Card to begin functioning almost immediately:
Q
Performing the Integrated Fast Setup procedure of the host CELLplex
7000, which configures all its interface cards in one session.
Q
Accessing the 7600 Card separately and performing its Multi-context
Fast Setup procedure.
The Integrated Fast Setup is recommended for most users.
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
3-2
CHAPTER 3: FAST SETUP
CELLplex 7000
Integrated Fast
Setup
The CELLplex 7000 Switch local management software features an
Integrated Fast Setup procedure which configures both the Switch and all
Interface Cards installed in it in one continuous dialog.
Box-oriented setup
The Integrated Fast Setup procedure is based on a concept in which the
CELLplex 7000 Switch together with its installed interface cards is viewed
as an integrated unit or box. The advantage of this point of view is its
simplicity: it is not necessary to remember into which slot each Interface
Card is installed or even which type of Interface Card is installed. Rather,
attention is focussed on configuring the ports of the box. The procedure
automatically determines the ports that are available in the box and
presents them by type (Ethernet, Fast Ethernet, ATM) for configuration.
The port location is displayed by the notation <slot.port>. For example
<3.1> refers to slot #3, port #1.
Box-wide vLANs
With the Integrated Fast Setup, Virtual LANs (vLANs) are created
box-wide. Each vLAN is defined for both the Switch and all the Interface
Cards installed in the box. There is only one admin vLAN for the box.
vLANs are set up in two stages. First, in the LE Client section, a number of
potential vLANs are created according to the requirement of the network.
Next, in the Virtual Network Configuration section, the potential vLANs
become actual vLANs by having ports assigned to them.
Setup Modes
The Integrated Fast Setup provides two setup modes: the “Full” setup
mode and the “Switch” setup mode.
Full Setup Mode
The Full setup mode configures both the CELLplex 7000 Switch and the
installed Interface Cards. It sets the required parameter values in all the
installed Interface Cards and is the preferred setup mode for most users.
In order to facilitate a more efficient procedure, the Full setup mode
presents only the most critical parameters; default values are assumed for
the remaining parameters.
Only those systems that require specific parameter settings in one or
more of the installed Interface Cards will need to use the Switch setup
mode as described in the next section.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
CELLplex 7000 Integrated Fast Setup
3-3
Switch Setup Mode
The Switch setup mode focusses only on the CELLplex 7000 Switch and
its ATM ports without altering Interface Card configuration. The Switch
setup mode is provided to allow you to retain special settings in the
Interface Cards.
Setup Mode Selection
If any of the settings in the following list are present in any Interface
Card, the operator is prompted to choose between the Switch and Full
setup modes:
Q
Q
Q
A Subnet Mask, Default Gateway or NMS Address different from
that of the CELLplex 7000 Switch
A vLAN whose ATM connection is set to “No”
The name of the ELAN that the default admin port (Port #1 in each
slot) is attached to differs from the name “admin”
If Full setup is selected, the parameters in the Interface Cards revert to
their default values.
If none of these situations are detected the Full setup mode is executed
automatically.
Setting Special Parameters
In case one or more individual Interface Cards requires one of the
special situations referred to in the previous section or needs to remain
unaltered, you will need to do one of the following:
Q
Q
Use the Switch setup mode of the Integrated Fast Setup to set up
the CELLplex 7000 Switch only and then use the Multi-context Fast
Setup of each installed Interface Card separately (see
“Multi-context Fast Setup” on page 3-10).
Use the Full setup mode of the Integrated Fast Setup to configure
the CELLplex 7000 Switch and all installed Interface Cards and
then use the Multi-context Fast Setup for the particular Interface
Card in order to restore its special parameter values.
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
3-4
CHAPTER 3: FAST SETUP
Setup Procedure
Sections
The Integrated Fast Setup consists of the following steps or sections:
Table 3-1 Integrated Fast Setup Procedure Sections
Navigation Aids
Setup Section
Description
Network Prefix
See CELLplex 7000 Manual.
LE Parameters
See CELLplex 7000 Manual.
LECS Address
See CELLplex 7000 Manual.
UNI/NNI parameters
See CELLplex 7000 Manual.
LE Client Configuration
Potential vLANs are defined by assigning
names to ELANs. Exit this section by pressing
Enter only.
Virtual Network
Configuration
Box ports are assigned to potential vLANs.
Admin VN Management
Configuration
Sets up admin vLAN in all modules including
setting IP address. See CELLplex 7000
Manual.
Confirmation
Setup is confirmed by operator.
The following short-cut characters are provided to move between
sections of the setup procedure:
Table 3-2 Setup Procedure Navigation Aids
Type:
To perform:
<
Jump to previous section.
>
Jump to next section.
>S
Jump to section according to double underlined ID letter in section
title.
\
Jump to beginning of setup.
$
Jump to end of setup.
}G
Jump to slot #G (in VN Configuration section).
+I
Jump to port #I (in VN Configuration section).
*
Update and duplicate to all slot items (in VN Configuration section).
**
Update and duplicate to all section items (in VN Configuration
section).
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
CELLplex 7000 Integrated Fast Setup
Integrated Fast Setup
Operation
3-5
The Integrated Fast Setup is initiated from the LMA Main Menu of the
CELLplex 7000. The CELLplex Main Menu appears as follows:
CP7000 switch module - Main Menu:
(1) SYS: Platform config ->
(2) LEM: Lan Emulation ->
(3) CON: Connections ->
(4) STS: Statistics ->
(5) DIA: Testing & Diagnostics ->
(6) FTR: ATM features
(7) LOG: Logout
(8) VER: Version
(9) FST: Fast Setup
(10) DBG: Debug ->
[ ‘\’ -Main,
‘-’ -Back in menus]
[ ‘=0’-To switch, ‘=n’-To i/f card n (1-4)]
>
Select the menu item: (9) FST: Fast Setup
Note that the Integrated Fast Setup “Full” setup mode may override any
specific configurations that have previously been carried out in any of the
installed Interface Cards. The following warning message is displayed
when this is about to occur:
***Note: Full fast setup, special module configuration will
be overridden.
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
3-6
CHAPTER 3: FAST SETUP
Example Dialog
The following dialog appears on the screen:
Now reading the modules configuration, please wait ...
Special module configuration will be overridden by fast setup.
continue full fast setup or only switch fast setup (S<witch>, F<ull>): F
***Note: Full fast setup, special module configuration will be overridden.
Fast Setup Utility
==================
The flash configuration will be displayed below;
Update if needed, and then hit Enter.
To move between sections, enter the following characters at end of line:
< > - Back and forth in sections
>S
- Jump to section ID S
\
- Back to beginning of setup
$
- To end of setup
Only in Virtual Network Configuration section (group=slot; item=port):
}G
- Jump to group #G
+I
- Jump to item #I
*
- Update all group items
**
- Update all section items
Network Prefix Section
Network Prefix
=------------*** Note: Recommended Network Prefix ->
47.00.00.00.00.00.3c.00.00.a*
Network Prefix(In HEX): 47.00.00.00.00.00.3c.00.00.a*
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
CELLplex 7000 Integrated Fast Setup
LE Parameters Section
LE parameters
=-----------Resident LECS state (1-Enable, 0-Disable): 0
LES state (1-Enable, 0-Disable): 0
LECS Address Section
LECS Address
--=--------Active LECS addr - net prefix: 47.00.00.00.00.00.3c.00.00.a*
Active LECS addr - user part: 00.a0.3e.00.00.01.00
UNI/NNI Parameters Section
UNI/NNI parameters
=----------------NNI max hops (0 - 120): 7
NNI type of port <3.1> (U<NI>,
NNI type of port <3.2> (U<NI>,
NNI type of port <3.3> (U<NI>,
NNI type of port <3.4> (U<NI>,
NNI type of port <4.1> (U<NI>,
NNI type of port <4.2> (U<NI>,
NNI type of port <4.3> (U<NI>,
NNI type of port <4.4> (U<NI>,
NNI type of port <5.1> (U<NI>,
NNI type of port <5.2> (U<NI>,
NNI type of port <5.3> (U<NI>,
NNI type of port <5.4> (U<NI>,
NNI type of port <6.1> (U<NI>,
NNI type of port <6.2> (U<NI>,
NNI type of port <6.3> (U<NI>,
NNI type of port <6.4> (U<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
N<NI>,
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
G<ateway>):
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
U
3-7
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
3-8
CHAPTER 3: FAST SETUP
LE Client Configuration Section
LE Client Configuration
-=---------------------
*** Hit Enter after VN #7 for end of potential ELAN names list.
VN #1 ELAN Name: admin
< Admin VN >
VN #2 ELAN Name: finance
VN #3 ELAN Name: engineering
VN #4 ELAN Name: engineering2
VN #5 ELAN Name: marketing
VN #6 ELAN Name: sales
VN #7 ELAN Name: office
VN #8 ELAN Name: foreign
VN #9 ELAN Name: reserve
VN #10 ELAN Name: marketing
*** VN #5 already has this ELAN name.
VN #10 ELAN Name: secret
VN #11 ELAN Name:
Virtual Network Configuration Section
Virtual Network Configuration
=---------------------------Fast Ethernet <3.1> belongs to VN # (1-6): 1 < Admin VN >
Fast Ethernet <3.2> belongs to VN # (1-6): 2
Fast Ethernet <3.3> belongs to VN # (1-6): 2
Fast Ethernet <3.4> belongs to VN # (1-6): 3
Fast Ethernet <3.5> belongs to VN # (1-6): 3
Fast Ethernet <3.6> belongs to VN # (1-6): 4
Fast Ethernet <3.7> belongs to VN # (1-6): 4
Fast Ethernet <3.8> belongs to VN # (1-6): 5
Fast Ethernet <3.9> belongs to VN # (1-6): 5
Fast Ethernet <3.10> belongs to VN # (1-6): 5
Fast Ethernet <3.11> belongs to VN # (1-6): 6
Fast Ethernet <3.12> belongs to VN # (1-6): 6
Fast Ethernet <3.13> belongs to VN # (1-6): 6
Fast Ethernet <3.14> belongs to VN # (1-6): 6
Fast Ethernet <3.15> belongs to VN # (1-6): 6
Fast Ethernet <3.16> belongs to VN # (1-6): 6
*** Note: no ports assigned to VN #6 - ELAN : sales
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
CELLplex 7000 Integrated Fast Setup
Admin VN Management Configuration Section
Admin VN Management Configuration
----------=----------------------Switch IP address: 100.0.0.1
Slot #3 IP address: 100.0.0.100
NMS address: 255.255.255.0
Default Gateway: 255.255.255.255
Subnet Mask: 255.255.255.0
Confirmation Dialog Section
Accept Changes
=------------*** Note: Change of some parameters will take affect now!!
Save changes (Y/N)? Y
Are you sure (Y/N)? y
Saving NMS parameters...
Saving LE parameters...
Saving Network Prefix...
Saving resident LECS Address...
Saving active LECS Address...
Saving NNI parameters...
The switch new configuration has been saved.
Now applying the module in slot #4 ...
Due to new VN configuration, some saved static
entries in slot #4 have been invalidated.
The new VN configuration in slot #4 has been applied and saved.
Now applying the module in slot #5 ...
Due to new VN configuration, some saved static
entries in slot #5 have been invalidated.
The new VN configuration in slot #5 has been applied and saved.
All the modules new configuration has been applied.
3-9
abtthgde.book Page 10 Tuesday, June 23, 1998 10:29 AM
3-10
CHAPTER 3: FAST SETUP
Multi-context Fast
Setup
This section describes how to perform the card-specific Multi-context Fast
Setup to perform a rapid configuration of the 7600 Card.
Port Context
For the purpose of management, the 16 Fast Ethernet ports of the 7600
Card are divided into four contexts. These are displayed in the following
table:
.
Table 3-3 Port Context
Contex
t
#0
Contex
t
#1
Contex
t
#2
Contex
t
#3
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
The management menus and commands focus on one context at a time.
Each menu displays the currently active context. To work with a certain
port, first use the table to ascertain to which context the port belongs.
For example, ports 1, 2, 9, 10 belong to Context #1. Then change to that
context by entering “.n” where n is the context number. From that point
on, the menus related to the ports in that context are displayed.
The Multi-context Fast Setup procedure described in the next section runs
though all contexts automatically so that you can set up all the ports in
the device in one continuous dialog.
Setup Procedure
Sections
The following describes the main steps of the Multi-context Fast Setup:
Q
Virtual Network Configuration. Each Fast Ethernet port is assigned to
a logical bridge. Initially, all ports default to the “admin” vLAN. Bridge
0 is the default bridge to which port 1 is always initially assigned for
ease of management setup.
Q
Emulated LAN (ELAN) Configuration. The ELAN name and LES address
can be assigned for each logical bridge specified in the virtual network
configuration with an ATM connection. This information is necessary
for communication within virtual networks. All logical bridges
assigned to the same LES address or ELAN name, are defined as being
in the same ELAN.
Q
Management Configuration. The IP address and Network
Management Station (NMS) address, with their default gateways and
abtthgde.book Page 11 Tuesday, June 23, 1998 10:29 AM
Multi-context Fast Setup
3-11
subnet masks, can be assigned to each logical bridge defined in the
Virtual Network Configuration.
Q
Editing Guidelines
Navigation Aids
System Mode Configuration. The 7600 Card can be configured to
operate in one mode: LAN Emulation (LE).
The following are the editing rules for Fast Setup values:
Q
The current value of each parameter is displayed as though it has
already been typed and may be either altered and entered or
immediately entered as is.
Q
The parameters may be edited as detailed in Chapter 4.
The following short-cut characters are provided to move between
sections of the setup procedure:
Table 3-4 Setup Procedure Navigation Aids
Type:
To go to:
<
Previous section
>
Next section
+
Next parameter
-
Last parameter
$
‘Accept Changes’ section (if no changes have been
made, you quit Fast Setup and return to the Main
Menu)
\
Beginning of setup
abtthgde.book Page 12 Tuesday, June 23, 1998 10:29 AM
3-12
CHAPTER 3: FAST SETUP
Multi-context Setup
Operation
From the CELLplex 7000 Main Menu enter = <slot #> where <slot #> is
the number of the slot in which the 7600 Card is installed. The 7600 Card
admin Main Menu appears as in the following example:
Context #0 - main menu:
==========
[1] system - Administer System level functions ->
[2] ethernet - Administer Ethernet ports ->
[3] bridge - Administer Bridging ->
[4] atm - Administer ATM resources ->
[5] le - Administer LAN Emulation Clients ->
[6] vns - Administer Virtual Networks configuration ->
[7] management - Administer IP and SNMP ->
[8] quit - Logout of the administration console
[9] fast - Fast Setup
To perform the Multi-context Fast Setup use menu item [9]fast from
the main menu.
Sample Screen Dialog
The Multi-context Fast Setup appears as follows:
Multi-context Fast Setup Utility
=================================
Answer Y(es) or N(o), and then hit Enter.
To move between question, enter the following characters at end of line:
< > - Back and forth in sections \ - Back to beginning of setup
$ - To end of setup
Do you want to enter Fast Setup for context #0 (Y/N)?Y
abtthgde.book Page 13 Tuesday, June 23, 1998 10:29 AM
Multi-context Fast Setup
Virtual Network Configuration Section
Virtual Network Configuration
----------------------------Fast Ethernet port #1 belongs to Bridge No.(0-3): 0 <Admin VN>
Fast Ethernet port #2 belongs to Bridge No.(0-3): 0
Fast Ethernet port #3 belongs to Bridge No.(0-3): 1
.
.
.
#4
Bridge #0 ATM connection (Y/N)? Y <Admin VN>
Bridge #1 ATM connection (Y/N)? Y
ELAN Configuration Section
Emulated LAN (ELAN) Configuration
--------------------------------Enable get LECS address via ILMI (Y/N)?
Bridge #0 ELAN name: elan156_0
Bridge #0 LES: 11.22.33.44.55.66.77.88.99.0.aa.bb.cc.dd.ee.ff.11.22.33.44
Management Configuration Section
Management Configuration
-----------------------Bridge #0 IP Addr: 140.204.140.177
Bridge #0 Default Gateway: 140.204.140.99
Bridge #0 Subnet Mask: 255.255.0.0
Bridge #0 NMS Addr: 140.204.140.165
Bridge #1 IP Addr: 140.204.140.178
Bridge #1 Default Gateway: 140.204.140.99
Bridge #1 Subnet Mask: 255.255.0.0
Bridge #1 NMS Addr: 140.204.140.166
3-13
abtthgde.book Page 14 Tuesday, June 23, 1998 10:29 AM
3-14
CHAPTER 3: FAST SETUP
System Mode Configuration Section
System Mode Configuration
------------------------Enter system mode (L<E>): L
The new configuration is displayed for this context.
Confirmation Dialog Section
Accept Changes (if changes have been made)
-------------Save changes (Y/N)? Y
This will apply the changes and reset the affected bridges only! Are you sure
(Y/N)?
At this point you are asked if you want to enter Fast Setup for contexts 1,
2, and 3.
abtthgde.book Page 15 Tuesday, June 23, 1998 10:29 AM
II
7600 CARD MANAGEMENT
TASKS
Chapter 4
Local Management Basics
Chapter 5
Configuring Virtual LANs
Chapter 6
Fast Ethernet and Bridge Management Tasks
Chapter 7
Managing ATM Resources
Chapter 8
Managing LAN Emulation Clients
Chapter 9
Setting Network Parameters
Chapter 10
Managing System Functions
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
4
LOCAL MANAGEMENT BASICS
This chapter describes the use of the 7600 Fast Ethernet Interface Card
Administration Console, its Main menu display and its controls. A Menu
Index is also included which provides a reference to the command
description for each menu command.
Management
Capabilities
The administration console configures your 7600 Card. It also provides
some network management capabilities. To augment network
management, you can use an external application, such as 3Com’s
TranscendTM Enterprise Manager ATMvLAN Manager.
Administration Console functions include:
Menu Hierarchy
Q
System functions administration
Q
Ethernet ports administration
Q
Basic bridge and port features administration
Q
ATM resources configuration
Q
LAN Emulation Clients administration
Q
Virtual Networks management
Q
IP address configuration for system access by Telnet, SNMP, or FTP
The management commands are organized in a hierarchical menu
system. At first, the Main menu is displayed showing the main topics for
management such as “system”, “ethernet” and “bridge”. Under each
main topic is a submenu which shows more specific command topics.
These submenus may themselves have submenus and so on until the
actual management commands are displayed. The menu structure
appears in Figure 4-1 below.
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
4-2
CHAPTER 4: LOCAL MANAGEMENT BASICS
Figure 4-1 Hierarchic menu structure
Main Menu
The Main menu is accessed from the CELLplex 7000 Main menu by
typing = <slot #> where “<slot #>” is the number of the slot in which
the 7600 Card is installed. Figure 4-2 shows the Main menu.
7600 Card in slot # 2 Context #0 - main menu:
==========
[1] system - Administer System level functions ->
[2] ethernet - Administer Ethernet ports ->
[3] bridge - Administer Bridging ->
[4] atm - Administer ATM resources ->
[5] le - Administer LAN Emulation Clients ->
[6] vns - Administer Virtual Networks configuration ->
[7] management - Administer IP and SNMP ->
[8] quit - Logout of the administration console
[9] fast - Fast Setup
Figure 4-2 Main menu
The arrow symbol (->) indicates that the menu option branches off into
one or more submenus.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Menu Hierarchy
4-3
Port Context
For the purpose of management, the 16 Fast Ethernet ports of the 7600
Card are divided into four contexts as follows:
.
Table 4-1 Port Context
Contex
t
#0
Contex
t
#1
Contex
t
#2
Contex
t
#3
9
10
11
12
13
14
15
16
1
2
3
4
5
6
7
8
The management menus and commands focus on one context at a time.
Each menu has the currently active context displayed above it. To work
with a certain port, use the above table to ascertain which context it is in.
For example, ports 1, 2, 9, 10 belong to context #1. Then change to
context n, by entering “.n” at the command prompt as discussed below.
From then on, the menus related to the ports in that context will be
displayed.
Selecting Menu
Options
The angle bracket symbol (>) is displayed below each menu and prompts
the keyboard entry of a menu option. A menu option can be entered
either by option number or option name. Only the first unique
character(s) of the menu option name needs to be entered.
For menu options below the Main menu, the menu option label precedes
the angle bracket prompt. Successive submenu prompts define the
hierarchical path from the most recently invoked (and most deeply
embedded) submenu to the original (root) Main menu option. When
there are no more submenus to call up, the last submenu option entered
produces a double angle bracket prompt (>>). This prompt indicates that
menu option parameters must now be entered.
Example
Thus, for example, entering 3 after the Main menu prompt produces the
bridge submenu, with its various options, and a command line
following the prompt:
(3)bridge>
Keying in this submenu’s 4 option gives you the prompt:
(3)bridge\(4)stp>,
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
4-4
CHAPTER 4: LOCAL MANAGEMENT BASICS
Entry of the stp submenu’s 3 option produces the prompt:
(3)bridge\(4)stp\(3)port>.
Finally, entering 1 finalizes the prompt as:
(3)bridge\(4)stp\(3)port\(1)display>>
Direct Access to
Submenus
To select an embedded sub-menu or settings-option several levels deep in
your current menu without having to step down through the sub-menus,
type all the intervening menu numbers or initial characters with blanks in
between. For example, if you wish to display the complete FDB table,
type b f d from the Main menu. This is a shortcut to selecting b (bridge)
on the Main menu, f (fdb) on the Bridging menu, and d (display) on the
Forwarding Database menu. The number sequence for this example
would be 3 3 1. In Part II, each command description includes the menu
sequence required to perform the command directly.
Should you enter an illegal character or string (such as an out-of-range
parameter), the display will respond with an error message indicated by a
three-asterisk (***) prefix.
Parameter Entry
When prompted for parameters, you can enter them all on the same
command line with blanks in between or you can enter some or all of
them on separate command lines. You are repeatedly prompted for the
remaining parameter as follows:
Enter parameter(s): ‘Bridge No. ‘ ‘Bridge Priority’
All or some of the parameters may also be entered in the same command
line immediately following the selected menu option or sequence of
menu options. In some instances separate prompts call for additional
parameters which must be entered in their individual prompt line.
Once all the parameters at the lowest submenu level have been entered,
the option is activated and the output is displayed.
Quick Key Functions
The following quick key functions are available when working with the
management menus. Table 4-2 covers navigating functions in the menu
system; Table 4-3 covers aids for editing parameters.
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Menu Hierarchy
Table 4-2 Menu Navigation Functions
Type:
To go to:
\
Main menu from any point.
-
Previous menu.
Left/Right Arrows
Back and forth within the command line.
Home
Beginning of the command line.
End
End of the command line.
.n
Context n (0-3)
=n
Another module
n=0: Switch module
n=1-4: Interface Card module 1-4
Table 4-3 Editing Aids
Type:
To perform:
<
Clear the value of the parameter last entered.
>
Clear the values of all the parameters in the list just
entered.
Up arrow
Retrieve a previous command.
Down arrow
Get the next command.
Backspace
Delete the character preceding the insertion point
Del
Delete the character following the insertion point.
Ins
Toggle between Insert and Overwrite modes.
5
Clear the command line.
$
Escape from prompt
4-5
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
4-6
CHAPTER 4: LOCAL MANAGEMENT BASICS
Menu Index
The following index shows where to find the description of each menu
action in the following chapters. The index has the same structure as the
menu hierarchy.
System Management Menu
[1] system
. . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . . . . . . . . 10--2
. . . . . . . [2] status. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10--3
. . . . . . . [3] update. . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3
. . . . . . . . . . . . . [5] mode. . . . . . . . . . . . . . . . . . . . . 10-6
. . . . . . . . . . . . . [6] s&f. . . . . . . . . . . . . . . . . . . . . . 10-7
. . . . . . . . . . . . . [7] tuning. . . . . . . . . . . . . . . . . . . . 10-7
. . . . . . . . . . . . . [8] timeout
..............
[1] info . . . . . . . . . . . . . . 10-8
..............
[2] display. . . . . . . . . . . . 10-11
..............
[3] hardware. . . . . . . . . . . 10-11
[4] software. . . . . . . . . . . 10-12
..............
. . . . . . . [5] flash. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-12
. . . . . . . [6] password
. . . . . . . . . . . . . [1] read. . . . . . . . . . . . . . . . . . . . . . 10-13
. . . . . . . . . . . . . [2] write. . . . . . . . . . . . . . . . . . . . . 10-13
. . . . . . . . . . . . . [3] admin. . . . . . . . . . . . . . . . . . . . 10-14
. . . . . . . [7] event. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-14
. . . . . . . [8] reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-15
. . . . . . . [9] load
. . . . . . . . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . 10-3
. . . . . . . . . . . . . [2] tftp. . . . . . . . . . . . . . . . . . . . . . 10-3
. . . . . . . . . . . . . [3] local. . . . . . . . . . . . . . . . . . . . . 10-4
Ethernet Menu
[2] ethernet
. . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
. . . . . . . [2] status. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-5
. . . . . . . [3] bcast
. . . . . . . . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . 6-5
. . . . . . . . . . . . . [2] update. . . . . . . . . . . . . . . . . . . . 6-6
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Menu Index
. . . . . . . . . . . . . . .[3] state. . . . . . . . . . . . . . . . . . . . . . . 6-6
. . . . . . . [4] update. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Bridge Menu
[3] bridge
. . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-8
. . . . . . . [2] port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
. . . . . . . [3] fdb
. . . . . . . . . . . . . . .[1] display. . . . . . . . . . . . . . . . . . . . . 6-12
. . . . . . . . . . . . . . .[2] learned. . . . . . . . . . . . . . . . . . . . . 6-14
. . . . . . . . . . . . . . .[3] static. . . . . . . . . . . . . . . . . . . . . . 6-15
. . . . . . . . . . . . . . .[4] allow. . . . . . . . . . . . . . . . . . . . . . 6-19
. . . . . . . . . . . . . . .[5] block. . . . . . . . . . . . . . . . . . . . . . 6-19
. . . . . . . . . . . . . . .[6] remove. . . . . . . . . . . . . . . . . . . . . 6-20
. . . . . . . [4] stp
. . . . . . . . . . . . . . .[1] display. . . . . . . . . . . . . . . . . . . . . 6-21
. . . . . . . . . . . . . . .[2] bridge
..............
[1] display. . . . . . . . . . . . . . 6-21
..............
[2] priority. . . . . . . . . . . . . . 6-24
..............
[3] max-age. . . . . . . . . . . . . 6-24
..............
[4] hello. . . . . . . . . . . . . . . 6-24
[5] forward. . . . . . . . . . . . . 6-25
..............
. . . . . . . . . . . . . . .[3] port
..............
[1] display. . . . . . . . . . . . . . 6-26
..............
[2] priority. . . . . . . . . . . . . . 6-27
..............
[3] cost . . . . . . . . . . . . . . . 6-28
[4] status. . . . . . . . . . . . . . . 6-27
..............
. . . . . . . . . . . . . . .[4] status. . . . . . . . . . . . . . . . . . . . . . 6-21
. . . . . . . [5] aging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-10
ATM Menu
[4] atm
. . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
. . . . . . . [2] address
. . . . . . . . . . . . . . .[1] display. . . . . . . . . . . . . . . . . . . . . 7-3
. . . . . . . . . . . . . . .[4] change. . . . . . . . . . . . . . . . . . . . . 7-4
4-7
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
4-8
CHAPTER 4: LOCAL MANAGEMENT BASICS
. . . . . . . [3] vcc
. . . . . . . [4] tm
. . . . . . . . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . 7-5
. . . . . . . . . . . . . [2] enable. . . . . . . . . . . . . . . . . . . . 7-6
. . . . . . . . . . . . . [3] client.
..............
[1] display. . . . . . . . . . . . 7-6
..............
[2] add . . . . . . . . . . . . . . 7-8
[3] remove. . . . . . . . . . . . 7-8
..............
. . . . . . . [6] uni. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
. . . . . . . [8] status. . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9
LAN Emulation Menu
[5] le
. . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . . . . . . . . 8-2
. . . . . . . [2] config
. . . . . . . . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . 8-4
. . . . . . . . . . . . . [4] cs-addr. . . . . . . . . . . . . . . . . . . 8-6
. . . . . . . . . . . . . [5] elan-name. . . . . . . . . . . . . . . . . 8-6
. . . . . . . . . . . . . [6] les-addr. . . . . . . . . . . . . . . . . . . 8-7
. . . . . . . . . . . . . [7] mode-lecs. . . . . . . . . . . . . . . . . 8-7
. . . . . . . [3] operational
. . . . . . . . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . 8-8
. . . . . . . . . . . . . [2] control. . . . . . . . . . . . . . . . . . . . 8-9
. . . . . . . . . . . . . [3] vcc. . . . . . . . . . . . . . . . . . . . . . 8-10
. . . . . . . . . . . . . [4] aging. . . . . . . . . . . . . . . . . . . . . 8-10
. . . . . . . . . . . . . [5] forward. . . . . . . . . . . . . . . . . . . 8-11
. . . . . . . . . . . . . [6] topology. . . . . . . . . . . . . . . . . . 8-11
. . . . . . . . . . . . . [7] arp. . . . . . . . . . . . . . . . . . . . . . . 8-11
. . . . . . . . . . . . . [8] flush. . . . . . . . . . . . . . . . . . . . . 8-12
. . . . . . . . . . . . . [9] path-switch. . . . . . . . . . . . . . . . 8-12
. . . . . . . . . . . . . [10] completion. . . . . . . . . . . . . . . . 8-13
. . . . . . . [4] lec-control. . . . . . . . . . . . . . . . . . . . . . . . 8-14
. . . . . . . [5] reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-17
. . . . . . . [6] flood. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-17
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
Menu Index
Virtual LAN Menu
[6] vns
. . . . . . . [1] display. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
. . . . . . . [4] ethernet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
. . . . . . . [5] atm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
Network Management Menu
[7] management
. . . . . . . [1] ip
. . . . . . . . . . . . . . .[1] display. . . . . . . . . . . . . . . . . . . . . 9-2
. . . . . . . . . . . . . . .[4] ip-addr. . . . . . . . . . . . . . . . . . . . . 9-2
. . . . . . . . . . . . . . .[5] gateway. . . . . . . . . . . . . . . . . . . . 9-3
. . . . . . . . . . . . . . .[6] mask. . . . . . . . . . . . . . . . . . . . . . 9-4
. . . . . . . [2] snmp.
. . . . . . . . . . . . . . .[1] display. . . . . . . . . . . . . . . . . . . . . 9-4
. . . . . . . . . . . . . . .[2] nms-addr. . . . . . . . . . . . . . . . . . . 9-5
4-9
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
5
CONFIGURING VIRTUAL LANS
This chapter contains detailed descriptions of common management
tasks for Virtual LANs (vLANs) connected to the 7600 Card. Please see
“Virtual LANs in the 7600 Card” on page 12-18 for general background
material concerning vLANs and how they are defined in the 7600 Card.
Connecting local Fast Ethernet segments to a vLAN over ATM is
accomplished by connecting them to the 7600 Card bridge and ensuring
that there is an internal ATM connection to an ELAN. For general
information about bridges see “Bridges in the 7600 Card” on page
12-10. The following bridge configuration tasks are covered:
Configuring Bridges
Display Current
Bridge
Configuration
Q
Display current bridge configuration 5-1
Q
Attach Fast Ethernet port to bridge 5-2
Q
Attach internal ATM port to bridge5-3
Displays the bridge configuration information for all bridges defined in
the 7600 Card. For general information about bridges see “Bridges in the
7600 Card” on page 12-10.
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
5-2
CHAPTER 5: CONFIGURING VIRTUAL LANS
Table 5-1 Task Actions
Menu
Sequence
[6] vns
[1] display
Enter
Result
None
Current bridge configuration
parameters are displayed
Table 5-2 Bridge Configuration Parameters
Parameter
Description
Bridge
The bridge number
Fast Ethernet Ports
The Fast Ethernet ports assigned to the bridge.
ATM
Q
Yes: The internal ATM downlink port is assigned to
the bridge (i.e., the bridge is connected to an ELAN)
Q
No: The internal ATM downlink port is not assigned
to the bridge
ELAN name
The ELAN name (if connected).
Example
Enter: [6] [1]
The following is displayed:
---------------------------------------------------------------------------| Bridge |
Ethernet ports
| ATM |
ELAN name (ATM)
+--------+-------------------------+-----+---------------------------------| 0
| 1-2
| YES | elan3576_0
| 1
| 3-4
| YES | elan3576_1
Figure 5-1 Bridge Configuration Display
Attach Fast
Ethernet Port to
Bridge
Enter the bridge number and a Fast Ethernet port to attach a specific Fast
Ethernet port to the bridge. The initial default configuration is a single
bridge that includes all Fast Ethernet ports and an ATM connection. For
general information about bridges see “Bridges in the 7600 Card” on
page 12-10.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Attach Internal ATM Port to Bridge
5-3
Table 5-3 Task Actions
Menu
Sequence
[6]vns
[4] ethernet
Enter
Result
1 Bridge Number {0-3}
Specified Fast Ethernet port is
attached to specified bridge
2 Fast Ethernet Port Number
{1-4}
Example
Enter: [6] [4] 1 3
Fast Ethernet port #3 is attached to bridge #1.
Attach Internal
ATM Port to Bridge
Enter the bridge number and Y/N to attach/detach the internal ATM
downlink port to an bridge. The initial default configuration is a single
bridge that includes all Fast Ethernet ports and an ATM connection. For
general information about bridges see “Bridges in the 7600 Card” on
page 12-10.
The ATM port in context #1 must always be attached to bridge #0.
Table 5-4 Task Actions
Menu
Sequence
[6] vns
[5] atm
Enter
Result
1 Bridge Number {0-3}
Q
Y: ATM port is attached to
specified bridge
Q
N: ATM port is detached from
specified bridge
2 Y/N
Example
Enter: [6] [5] 0 Y
The internal ATM port is attached to bridge #0.
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
6
FAST ETHERNET AND BRIDGE
MANAGEMENT TASKS
This chapter contains detailed descriptions of common management
tasks for Fast Ethernet LANs connected to the 7600 Card. Refer to
Chapter 11 “Ethernet LANs and Bridges in the 7400 Card” for general
background material concerning Ethernet LANs. The following tasks are
covered:
Managing Fast Ethernet Ports
Q
Fast Ethernet Port Attributes and Statistics
Q
Disable a Fast Ethernet Port
Q
Display Broadcast Throttling Attributes
Q
Update Broadcast Threshold
Q
Enable/Disable Broadcast Throttling
Q
Update Fast Ethernet Port
Managing Ethernet Bridges
Q
Display Broadcast Throttling Attributes
Q
Update Bridge-aging- time
Q
Bridge-port Attributes and Statistics
Managing the Bridge Forwarding Database
Q
Display All Entries in Forwarding Database
Q
Display Learned Entries in Forwarding Database
Q
Display Static Entries in Forwarding Database
Q
Enter or Modify a Static Address in FDB
Q
Block a Static Address
Q
Remove a Static Address from FDB
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
6-2
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Managing the Spanning Tree Protocol - Bridge-wide
Q
Display STP Enable Status
Q
Disable STP on Bridge
Q
Display Bridge STP Attributes
Q
Update Bridge-wide STP Parameters
Q
Update Bridge-priority
Q
Update Bridge-max-age
Q
Update Bridge-hello-time
Q
Update Bridge-forward- delay
Managing the Spanning Tree Protocol - per Bridge-port
Fast Ethernet Port
Attributes and
Statistics
Q
Display Bridge-port STP Attributes
Q
Disable Bridge-port
Q
Update Bridge-port STP parameters
Q
Update Bridge-port- priority
Q
Update Bridge-path-cost
Dsplays the Fast Ethernet port attributes and statistics for a specified Fast
Ethernet port (see “Fast Ethernet Ports” on page 11-5 for general
information about Ethernet ports).
Table 6-1 Task Actions
Menu
Sequence
[2] ethernet
[1] display
Enter
Result
Fast Ethernet port number {1-4}
Port attributes and statistics
are displayed
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Fast Ethernet Port Attributes and Statistics
Table 6-2 Ethernet Port Attributes
Name
Description
MAC Address
The MAC address uniquely identifying the Ethernet port.
Admin Status
The Port administrative status.
Oper Status
Q
Up: Port is enabled by management
Q
Down: Port is disabled by management
The Port operational status.
Q
Up: Port is connected and operational
Q
Down: Port is not connected or not operational
Table 6-3 Fast Ethernet Port Characteristics
Name
Description
Installed
Indicates whether Fast Ethernet port is installed: Yes or No
Type
Type of Fast Ethernet Port: Fx (Fiber) or Tx (Copper)
Mode
Auto-negotiation mode:
Q
No auto-negotiation
Q
All auto-negotiation
Q
Duplex auto-negotiation
Q
Speed auto-negotiation
Duplex
Transmission mode: Full or half duplex
Speed
Transmission speed: 10M or 100M
.
Table 6-4 Ethernet Port Statistics
Name
Description
In Octets
All octets received on the port.
In Ucast
Unicast frames received on the port excluding discards.
In Mcast
Multicast frames received on the port excluding discards.
In Bcast
Broadcast frames received on the port excluding discards.
In Discards
All frames received on the port and discarded for internal
reasons, for example, queues.
In Errors
All frames received on the port and discarded due to errors.
6-3
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
6-4
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Table 6-4 Ethernet Port Statistics (continued)
Name
Description
In Unknown
All frames received on the port and discarded due to unknown
protocols.
Out Octets
All octets transmitted out of the port.
Out Ucast
Unicast frames transmitted out of the port including discards.
Out Mcast
Multicast frames transmitted out of the port including discards.
Out Bcast
Broadcast frames transmitted out of the port including discards.
Out Discards
All frames not transmitted out of the port for internal reasons.
Out Errors
All frames not transmitted out of the port due to errors.
Example
Enter: [2] [1] 1
The following information for Port #1 is displayed:
-------------------------------------------------------Ethernet port 1:
=================
Mac address : 00c0da1803c0
Installed : Yes
Type
: Fx
Mode
: Non-Autonegotiation
Duplex
: Full
Speed
: 100M
Admin Status : Up
Oper Status : Up
Statistics:
----------In Octets : 1188250808 Out Octets : 19034810
In Ucast
: 0 Out Ucast : 419
In Mcast
: 0 Out Mcast : 0
In Bcast
: 0 Out Bcast : 1
In Discards : 13Out Discards: 0
In Errors
: 0 Out Errors : 0
In Unknown : 0
---------------------------------------------------------
Figure 6-1 Fast Ethernet Port Attributes and Statistics Display
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Disable a Fast Ethernet Port
Disable a Fast
Ethernet Port
6-5
Disable or enable the Admin status of a Fast Ethernet port (see “Fast
Ethernet Ports” on page 11-5 for general information about Ethernet
ports).
Table 6-5 Task Actions
Menu
Sequence
[2] ethernet
[2] status
Enter
Result
1 Ethernet port number {1-4}
Administrative Status of Port is
enabled or disabled
2 U(p)/D(own)
Example
Enter: [2] [2] 4 U
Ethernet Port 4 is enabled.
The following message is displayed on the screen:
Context #0 Event: Ethernet port #4 is Link Up
Display Broadcast
Throttling
Attributes
Displays broadcast throttling attributes. Broadcast throttling can be set
for each port. When the number of broadcast frames through the port
exceeds the high threshold, frames are discarded. When the number of
broadcast frames goes below the low threshold the frames are retained.
Table 6-6 Task Actions
Menu
Sequence
[2] ethernet
[3] bcast
[1] display
Enter
Result
None
Broadcast throttling attributes are
displayed
Table 6-7 Broadcast Throttling Attributes
Name
Description
High threshold
The broadcast transmission rate limit above which broadcast
frames are discarded (in frames/second).
Low threshold
The broadcast transmission rate limit below which broadcast
frames are not discarded (in frames/second).
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
6-6
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Table 6-7 Broadcast Throttling Attributes (continued)
Name
Description
Enable status
Broadcast throttling enabled/disabled for this port.
Example
Enter: [2] [3] [1]
The following is displayed:
---------------------------------------------------------------------Port #1: high threshold
500
low threshold 300
Enabled
Port #2: high threshold
500
low threshold 300
Enabled
Port #3: high threshold
500
low threshold 300
Enabled
Port #4: high threshold
500
low threshold 300
Enabled
Broadcast throttling feature is enabled.
-----------------------------------------------------------------------
Figure 6-2 Broadcast Throttling Attributes Display.
Update Broadcast
Threshold
Updates broadcast attributes.
Table 6-8 Task Actions
Menu
Sequence
[2] ethernet
[3] bcast
[2] update
Enter
Result
1 Ethernet port number {1-4}
The high and low thresholds are
updated
2 High Threshold
3 Low Threshold
Example
Enter: [2] [3] [2] 4 500 300
The high and low thresholds for port 4 are updated.
Enable/Disable
Broadcast Throttling
Disable or enable broadcast throttling for a specific port (see “Fast
Ethernet Ports” on page 11-5 for general information about Ethernet
ports). Entering “Enable” returns the previous threshold values.
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Update Fast Ethernet Port
6-7
Table 6-9 Task Actions
Menu
Sequence
[2] ethernet
[3] bcast
[3] state
Enter
Result
1 Ethernet port number {1-4}
Broadcast throttling for the
port is (e)nabled or (d)isabled
2 D(isable)/E(nable)
Example
Enter: [2] [3] [3] 4 E
Broadcast throttling for Port 4 is enabled.
Update Fast
Ethernet Port
Updates Fast Ethernet port attributes. For more information see “Fast
Ethernet Port Characteristics” on page 6-3 and see “Fast Ethernet Ports”
on page 11-5.
The parameter inputs differ between the Tx (copper) and Fx (fiber) port
types due to their different capabilities. The Fx port type permits only the
entry of a fixed parameter for the duplex mode. The Tx port type allows
selection of autonegotiation for speed and duplex mode individually. If
one of these is not selected for autonegotiation it must be given a fixed
parameter manually.
Table 6-10 Task Actions for Fx Port Type
Menu
Sequence
[2] ethernet
[4] update
Enter
Result
1 Ethernet port number {1-4}
The Fast Ethernet Fx port
attributes are updated
2 Duplex (H<alf>, F<ull>)
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
6-8
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Table 6-11 Task Actions for Tx Port Type
Menu
Sequence
[2] ethernet
[4] update
Enter
Result
1 Ethernet port number {1-4}
The Fast Ethernet Tx port
attributes are updated.
2 Auto mode (N<on-Auto>,
A<ll>, D<uplx>, S<peed>)
3
*Speed
4
†Duplex
(10,100)
(H<alf>, F<ull>)
* If “D” or “N” was entered in Step 2
† If “S” or “N” was entered in Step 2
Example 1 - for Tx port type
Enter: [2] [4] 1 H
The Fast Ethernet Tx port #1 is set to half duplex.
Example 2 - for Fx port type
Enter: [2] [4] 1 D 10
The Fast Ethernet Tx port #1 is set to automode for duplex and a fixed
speed of 10 Mbps.
Bridge Attributes
and Statistics
Display the mapping of the bridge-ports to the Fast Ethernet ports on the
7600 Card as well as other bridge attributes and statistics. For more
information about bridges in Ethernet LANs see “Transparent Bridges” on
page 11-6.
Table 6-12 Task Actions
Menu
Sequence
[3] bridge
[1] display
Enter
Result
Bridge Number {0-3}
Bridge attributes and statistics are
displayed
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
Bridge Attributes and Statistics
6-9
Table 6-13 Bridge Attributes and Statistics
Name
Description
Bridge Address
The MAC address uniquely identifying the logical
bridge.
Bridge-port
The logical bridge-port number within the bridge.
Physical Port
The physical Ethernet port to which the logical
bridge-port is mapped.
Aging Time
The bridge aging time.
Learned Discards
Addresses that should have been learned, but were
discarded because of lack of space in the bridge’s
Forwarding Database.
Example
Enter: [3] [1] 0
The following is displayed.
-----------------------------------------------Bridge #0:
===========
Bridge address: 00c0da1803c0
Bridge STP is Disabled
| Bridge-port | Physical
|
+----------------------------------+
|
1
| Ethernet port 1 |
|
2
| Ethernet port 2 |
|
3
| Ethernet port 3 |
|
4
| Ethernet port 4 |
|
5
|
ATM port
|
Aging Time
: 900
Learned Discards : 0
-----------------------------------------------
Figure 6-3 Bridge Attributes and Statistics Display
abtthgde.book Page 10 Tuesday, June 23, 1998 10:29 AM
6-10
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Update
Bridge-agingtime
Update the bridge FDB parameter bridge-aging-time for a specified
bridge. For more information about bridges in Ethernet LANs see
“Transparent Bridges” on page 11-6.
Table 6-14 Task Actions
Menu
Sequence
[3] bridge
[5] aging
Enter
Result
1 Bridge number {0-3}
The bridge FDB parameter
bridge-aging-time for this
bridge is updated.
2 Bridge-aging-time (secs)
Example
Enter: [3] [5] 0 900
Sets the bridge-aging-time to 900 secs on bridge #0.
Bridge-port
Attributes and
Statistics
Displays the frame traffic statistics for a bridge-port. For more information
about bridges in Ethernet LANs see “Transparent Bridges” on page 11-6.
Table 6-15 Task Actions
Menu
Sequence
[3] bridge
[2] port
Enter
Result
1 Bridge number {0-3}
Bridge-port attributes and
statistics are displayed
2 Bridge-port Number {1-5}
Table 6-16 Bridge-port Attributes and Statistics
Name
Description
Bridge
The number of the bridge.
Port
The number of the bridge-port within the specified
bridge.
Physical
The physical port to which the bridge-port is mapped.
In Frames
All frames received on the port excluding discards.
Out Frames
All frames transmitted out of the port, including
discards.
In Discards
The number of frames received on the port, that were
filtered by the forwarding process.
abtthgde.book Page 11 Tuesday, June 23, 1998 10:29 AM
Bridge-port Attributes and Statistics
6-11
Table 6-16 Bridge-port Attributes and Statistics (continued)
Name
Description
Delay Exceeded Discards
The number of frames discarded by the port, due to
excessive transit delay through the bridge.
Maximum Transfer Unit
(MTU) Exceeded Discards
The number of frames discarded by the port, due to an
excessive size.
Example
Enter: [3] [2] 0 1
The following is displayed:
---------------------------------------------Bridge #0 Port 1:
===================
Physical: Ethernet port 1
In Frames
: 2
Out Frames
: 4
In Discards
: 0
Delay Exceeded Discards : 0
MTU Exceeded Discards
: 0
--------------------------------------------
Figure 6-4 Bridge Attributes and Statistics Display
abtthgde.book Page 12 Tuesday, June 23, 1998 10:29 AM
6-12
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Display All Entries
in Forwarding
Database
Displays the complete Forwarding Database (FDB) for the specified
bridge, including all addresses, the ports they are mapped to and their
status. Each database entry is identified by an address. For more
information about the Forwarding Database see “Forwarding Database”
on page 11-7.
Table 6-17 Task Actions
Menu
Sequence
[3] bridge
[3] fdb
[1] display
Enter
Result
1 Bridge number {0-3}
The contents of all address tables in
the bridge FDB are displayed.
Table 6-18 Forwarding Database Fields
Name
Description
Addr
The MAC address to which the entry relates.
Port
The bridge-port related to the entry.
Status
Status:
Q
Management - The port will always be zero.
Q
Self - The bridge-ports’ self-address.
Q
Learned - Learned address.
Example
Enter: [3] [3] [1] 0
The following is displayed:
abtthgde.book Page 13 Tuesday, June 23, 1998 10:29 AM
Display All Entries in Forwarding Database
----------------------------------------------------Addr: 0180c2000000 Port: 0 Status: Management
Addr: 01c0da000200 Port: 0 Status: Management
Addr: 0180c2000001 Port: 0 Status: Management
Addr: 0180c2000002 Port: 0 Status: Management
Addr: 0180c2000003 Port: 0 Status: Management
Addr: 0180c2000004 Port: 0 Status: Management
Addr: 0180c2000005 Port: 0 Status: Management
Addr: 0180c2000006 Port: 0 Status: Management
Addr: 0180c2000007 Port: 0 Status: Management
Addr: 0180c2000008 Port: 0 Status: Management
Addr: 0180c2000009 Port: 0 Status: Management
Addr: 0180c200000a Port: 0 Status: Management
Addr: 0180c200000b Port: 0 Status: Management
Addr: 0180c200000c Port: 0 Status: Management
Addr: 0180c200000d Port: 0 Status: Management
Addr: 0180c200000e Port: 0 Status: Management
Addr: 0180c200000f Port: 0 Status: Management
Addr: aabbccddeeff Port: 0 Status: Management
Addr: 0020af8dcd78 Port: 1 Status: Learned
Addr: 00c0da1803c0 Port: 1 Status: Self
Addr: 00c0da1803c1 Port: 2 Status: Self
Addr: 00c0da1803c2 Port: 3 Status: Self
Addr: 00c0da1803c3 Port: 4 Status: Self
Addr: 00c0da1803c4 Port: 3 Status: Self
Addr: 00c0da1803c5 Port: 2 Status: Self
Addr: 00c0da1803cc Port: 4 Status: Self
Addr: ffffffffffff Port: 0 Status: Management
-----------------------------------------------------
Figure 6-5 Forwarding Database Display
6-13
abtthgde.book Page 14 Tuesday, June 23, 1998 10:29 AM
6-14
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Display Learned
Entries in
Forwarding
Database
Displays only the learned entries in the Forwarding Database for the
specified bridge. Each entry is identified by an address. For more
information about learned entries in the Forwarding Database see
“Learning Station Addresses” on page 11-7.
Table 6-19 Task Actions
Menu
Sequence
[3] bridge
[3] fdb
[2] learned
Enter
Result
1 Bridge number {0-3}
The contents of the learned address
table in the bridge FDB are
displayed.
Table 6-20 Learned Forwarding Database Fields
Name
Description
Addr
The MAC address to which the entry relates.
Port
The bridge-port related to the entry.
Status
Status: Learned - Learned address.
Example
Enter: [3] [3] [2] 0
The following is displayed:
-----------------------------------------------------Total number of learned FDB entries: 1.
Addr: 0020af8dcd78 Port: 1 Status: Learned
------------------------------------------------------
Figure 6-6 Learned Forwarding Database Display
abtthgde.book Page 15 Tuesday, June 23, 1998 10:29 AM
Display Static Entries in Forwarding Database
Display Static
Entries in
Forwarding
Database
6-15
Displays only the static entries in the Forwarding Database for the
specified bridge. These entries are either predefined or have been
configured via management. For more information about static entries in
the Forwarding Database see “Static Addresses” on page 11-8.
Table 6-21 Task Actions
Menu
Sequence
[3] bridge
[3] fdb
[3] static
Enter
Result
1 Bridge number {0-3}
The contents of the static address
table in the bridge FDB are
displayed.
abtthgde.book Page 16 Tuesday, June 23, 1998 10:29 AM
6-16
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Table 6-22 Static Table Fields
Name
Description
Addr
The MAC address to which the entry relates.
Rcv-P
Allowed receive (input) port for this address. A zero in this field
means that all ports are allowed.
Alwd-to
Allowed output port(s) for this address. The allowed-to
information is displayed in binary form, with each digit referring
to 5 bridge-ports. Refer to Table 6-22 for the Allowed-To Binary
Table mapping.
M-ID
Member ID. If one of the destination ports is the ATM port, an
ATM Member ID which is used to identify the ATM destination
must be provided.
Stat
The status of the entry:
Q
Read-Only - Predefined entries that may not be removed or
updated.
Q
Permanent - Permanent entries that will remain across
system resets.
Q
Delete-On-Reset - Temporary entries that will be deleted
when the device is reset.
Q
Delete-On-Timeout - Temporary entries that will be deleted
after a specified period of time (aging time).
Q
Other-Bridge - An entry with this address exists for a
different bridge, and also affects this bridge. Entries of this
type will always be defined such that a frame is flooded to all
ports. These entries may not be removed or updated via this
bridge. However, they may be removed or updated via the
bridge they were defined for.
abtthgde.book Page 17 Tuesday, June 23, 1998 10:29 AM
Display Static Entries in Forwarding Database
6-17
Static Addresses Allowed-to Binary Table
The Allowed-to field specifies where the frames arriving on a given
address and bridge port must be forwarded to. This field consists of two
nibbles, each of which is a hexadecimal number whose binary value
signifies the bridge ports to be forwarded to within the specified bridge.
Five bits are used, corresponding to the 5 bridge ports - 4 Fast Ethernet
ports and 1 internal ATM port as shown in the following table.
Table 6-23 Hexadecimal Codes for Displaying Multiple Bridge Ports
Bridge Ports Hex Value Bridge Ports Hex Value
1 2 3 4
5 X X X
0001
1
0001
1
0010
2
0010
2
0011
3
0011
3
0100
4
0100
4
0101
5
0101
5
0110
6
0110
6
0111
7
0111
7
1000
8
1000
8
1001
9
1001
9
1010
a
1010
a
1011
b
1011
b
1100
c
1100
c
1101
d
1101
d
1110
e
1110
e
1111
f
1111
f
If, for example, the Allowed-to field is “f800”, then the frames will be
forwarded to bridge ports 1, 2, 3, 4, and 5. If the Allowed-to field is
“1800” then the frames will be forwarded to bridge ports 4 and 5.
abtthgde.book Page 18 Tuesday, June 23, 1998 10:29 AM
6-18
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Example
Enter: [3] [3] [3] 0
The following is displayed:
----------------------------------------------------------------------Addr: 0180c2000000 Rcv-P: 0 Alwd-to: fe00 M-ID: Stat: Read-Only
Addr: 01c0da000200 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000001 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000002 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000003 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000004 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000005 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000006 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000007 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000008 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c2000009 Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c200000a Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c200000b Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c200000c Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c200000e Rcv-P: 0 Alwd-to: 0000 M-ID: ---- Stat: Read-Only
Addr: 0180c200000f Rcv-P: 0 Alwd-to: 0100 M-ID:
21 Stat: Read-Only
Addr: 0180c2000010 Rcv-P: 0 Alwd-to: f100 M-ID:
0 Stat: Read-Only
Addr: 0180c2000011 Rcv-P: 0 Alwd-to: 1100 M-ID:
23 Stat: Other-Brg
Addr: 0180c2000012 Rcv-P: 0 Alwd-to: f100 M-ID:
0 Stat: Del-On-TO
Addr: 0180c2000013 Rcv-P: 0 Alwd-to: 1100 M-ID:
24 Stat: Permanent
Addr: 0180c2000014 Rcv-P: 0 Alwd-to: f100 M-ID:
0 Stat: Read-Only
-----------------------------------------------------------------------
Figure 6-7 Static Table Display
abtthgde.book Page 19 Tuesday, June 23, 1998 10:29 AM
Enter or Modify a Static Address in FDB
Enter or Modify a
Static Address in
FDB
6-19
Add a new static address to the FDB or update an existing one. The static
entry is added to the Forwarding Database or updated with new
destinations if it exists. A new entry is given a permanent status. Other
status values may be given using an SNMP manager. For more
information about static entries in the Forwarding Database see “Static
Addresses” on page 11-8.
Table 6-24 Task Actions
Menu
Sequence
[3] bridge
[3] fdb
[4] allow
Enter
Result
1 Bridge number {0-3}
If the station address does not
exist in the static address table
2 Station address (MAC address)
of the FDB, it is added to it and
3 Input bridge-port number {0-5, receives the permanent status.
If the address already exists, the
(0 for all ports)}
ports are updated if they are
4 Output bridge-port number(s)
different from those specified.
{1-5} and
Member ID (for the ATM port)
Example
Enter: [3] [3] [4] 0 0180c2000000 1 2
In the static Forwarding Database of bridge #0, the MAC address
0180c2000000 is allowed for input bridge-port #1 and output bridge port
#2.
Block a Static
Address
Specify bridge-ports on which communication is blocked for a static
address in the FDB. For more information about static entries in the
Forwarding Database see “Static Addresses” on page 11-8.
The blocked input and output bridge ports are specified by single
hexadecimal numbers as in Table 6-20.
abtthgde.book Page 20 Tuesday, June 23, 1998 10:29 AM
6-20
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Table 6-25 Task Actions
Menu
Sequence
[3] bridge
[3] fdb
[5] block
Enter
Result
1 Bridge number {0-4}
Communication is blocked on the
specified ports for the static
station address specified.
2 Station address (MAC
address)
3 Input bridge-port number
{0-5), (0 for all ports)}
4 Output bridge-port
number(s) {1-5} or
Member ID (for the ATM
port)
Example
Enter: [3] [3] [5] 0 0180c2000000 1 4
In the static Forwarding Database of bridge #0, the MAC address
0180c2000000 is blocked for input bridge-port #1 and output bridge
ports #4.
Remove a Static
Address from FDB
Specify a bridge number, Ethernet MAC address, and bridge-port number
of the static entry (address) that you want to remove from the Forwarding
Database. For more information about static entries in the Forwarding
Database see “Static Addresses” on page 11-8.
Table 6-26 Task Actions
Menu
Sequence
[3] bridge
[3] fdb
[6] remove
Enter
Result
1 Bridge number {0-3}
The station address is removed
from the static address table of
the FDB.
2 Station address (MAC
address)
3 Input bridge-port number
{0-5), (0 for all ports)}
Example
Enter: [3] [3] [6] 0 0180c2000000 1
abtthgde.book Page 21 Tuesday, June 23, 1998 10:29 AM
Display STP Enable Status
6-21
In the static Forwarding Database of bridge #0, the MAC address
0180c2000000 is removed for input bridge-port #1.
Display STP Enable
Status
Display STP enable status for all bridges. For general information about
the STP see “Spanning Tree Protocol” on page 11-8. For more
information about the STP enable status see “Disabling the STP” on page
11-10.
Table 6-27 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[1] display
Enter
Result
None
The STP enable/disable status is
displayed for this bridge.
Example
Enter: [3] [4] [1]
The following is displayed:
STP Status
----------Bridge #0: STP is Disabled
Figure 6-8 STP Enable Status Display
Disable STP on
Bridge
Disable and enable the STP on a specified bridge. For more information
about the STP enable status see “Disabling the STP” on page 11-8.
Table 6-28 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[4] status
Enter
Result
1 Bridge number {0-3}
(D)isables or (E)nables STP on
this bridge.
2 D(isable)/E(nable)
abtthgde.book Page 22 Tuesday, June 23, 1998 10:29 AM
6-22
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Example
Enter: [3] [4] [4] 0 D
Disables the STP on bridge 0 and produces the following message:
Bridge #0: STP is now disabled.
Display Bridge STP
Attributes
Display all STP attributes for a specified bridge. For general information
about the STP and about the STP parameters see “Spanning Tree
Protocol” on page 11-6.
Table 6-29 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[2] bridge
[1] display
Enter
Result
1 Bridge number {0-3}
The STP attributes are displayed
for this bridge.
Table 6-30 Bridge STP Attributes
Parameter
Description
Bridge-Protocol
The STP version (as in IEEE 802.1D).
Bridge-Priority
A 2-octet value that allows the network manager to
influence the choice of root bridge and the designated
bridge.
Bridge-Topology-Changes The number of topology changes which have occurred
since the bridge was last reset.
Bridge-Designated-Root
The bridge assumed to be the root bridge.
Root-Cost
The cost of the path from this bridge to the root
bridge.
Root-Port
The port that offers the lowest cost path to the root
bridge.
Max-Age
The message age value at which a stored CBPDU is
discarded.
Hello-Time
The time interval between the transmission of CBPDUs.
Forward-Delay
The time spent in the listening and the learning state
while the Spanning tree is re-configuring.
abtthgde.book Page 23 Tuesday, June 23, 1998 10:29 AM
Display Bridge STP Attributes
6-23
Table 6-30 Bridge STP Attributes (continued)
Parameter
Description
Hold-Time
A fixed bridge parameter specifying the minimum time
period elapsing between the transmission of CBPDUs
through a given bridge-port. No more than two
CBPDUs shall be transmitted in any Hold-Time period.
Bridge-Max-Age
The value of the Max-Age parameter when the bridge
is, or is attempting to become, the Root.
Bridge-Hello-Time
The value of the Hello-Time parameter when the
bridge is, or is attempting to become, the Root.
Bridge-Forward-Delay
The value of the Forward-Delay parameter when the
bridge is, or is attempting to become, the root bridge.
Example
Enter: [3] [4] [2] [1] 0
The STP attributes for bridge #0 is displayed as follows:
bridge #0 STP Attributes:
===========================
bridge STP is Disabled.
bridge Protocol= 3
bridge Priority= 32768
bridge Topology Changes= 4
bridge Designated Root= 800000c0da1800a0
Root Cost= 0
Root Port= 0
bridge Time Since Topology Change= 16313875
Max-Age= 2000
Hello Time= 200
Forward Delay= 1500
Hold Time= 100
bridge Max-Age= 2000
bridge Hello Time= 200
bridge Forward Delay= 1500
Figure 6-9 Bridge STP Attributes Display
abtthgde.book Page 24 Tuesday, June 23, 1998 10:29 AM
6-24
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Update
Bridge-wide STP
Parameters
Update
Bridge-priority
Update bridge STP parameters: bridge-priority, bridge-max-age,
bridge-hello-time, and bridge-forward-delay (see “Management Bridge
Parameters” on page 11-8 for more information about the STP
parameters).
Update the STP parameter bridge-priority for a specified bridge.
Table 6-31 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[2] bridge
[2] priority
Enter
Result
1 Bridge number {0-3}
The STP parameter
bridge-priority for this bridge is
updated.
2 Bridge-priority
Example
Enter: [3] [4] [2] [2] 0 32768
The bridge-priority for bridge #0 is set to 32768
Update
Bridge-max-age
Update the STP parameter bridge-max-age for a specified bridge.
Table 6-32 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[2] bridge
[3] max-age
Enter
Result
1 Bridge number {0-3}
The STP parameter
bridge-max-age for this bridge
is updated.
2 Bridge-max-age (secs)
Example
Enter: [3] [4] [2] [3] 0 2000
The bridge-max-age for bridge #0 is set to 2000 secs.
Update
Bridge-hello-time
Update the STP parameter bridge-hello-time for a specified bridge.
abtthgde.book Page 25 Tuesday, June 23, 1998 10:29 AM
Update Bridge-wide STP Parameters
6-25
Table 6-33 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[2] bridge
[4] hello
Enter
Result
1 Bridge number {0-3}
The STP parameter
bridge-hello-time for this bridge
is updated.
2 Bridge-hello-time
Example
Enter: [3] [4] [2] [4] 0 2000
The bridge-hello-time for bridge #0 is set to 2000 secs.
Update
Bridge-forwarddelay
Update the STP parameter bridge-forward-delay for a specified bridge.
Table 6-34 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[2] bridge
[5] forward
Enter
Result
1 Bridge number {0-3}
The STP parameter
bridge-forward-delay for this
bridge is updated.
2 Bridge-forward-delay
Example
Enter: [3] [4] [2] [5] 0 1500
The bridge-forward-delay for bridge #0 is set to 1500 secs.
abtthgde.book Page 26 Tuesday, June 23, 1998 10:29 AM
6-26
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Display Bridge-port
STP Attributes
Display all STP attributes for a specified bridge-port.
Table 6-35 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[3] port
[1] display
Enter
Result
1 Bridge number {0-3}
The STP attributes are displayed
for this bridge-port.
2 Bridge-port number {0-5), (0
for all ports)}
Table 6-36 Bridge-port STP Attributes
Parameter
Description
Bridge-PortPriority
A 1-octet value that allows the network manager to influence the
choice of port when a bridge has two ports connected in a loop.
Bridge-PortState
The current state of the port: Disabled, Listening, Learning,
Forwarding, or Blocking.
Bridge-PortPath-Cost
The cost to be added to the root-path-cost field to determine the
cost of the path to the root through this port.
Bridge-PortDesignatedRoot
ID of the bridge in the root-identifier parameter transmitted by
the designated-Bridge for the LAN to which the port is attached.
Bridge-PortDesignatedCost
Cost of the path to the root-bridge offered by the
designated-port on the LAN to which this port is attached.
Bridge-PortDesignatedBridge
ID of the bridge assumed to be the designated-bridge for the
LAN associated with the port. The parameter is used: (a) together
with the designated-port and port-identifier parameters for the
port to ascertain whether this port should be the designated-port
for the LAN to which it is attached; (b) to test the value of the
bridge Identifier parameter conveyed in received CBPDUs.
Bridge-PortDesignatedPort
The port-identifier of the bridge-port assumed to be the
designated-port for the LAN associated with the port. The
parameter is used: (a) together with the designated-bridge and
port-identifier parameters for the Port to ascertain whether this
Port should be the designated-port for the LAN to which it is
attached; (b) by management to determine the topology of the
bridged Local Area Network..
Example
Enter: [3] [4] [3] [1] 0 1
abtthgde.book Page 27 Tuesday, June 23, 1998 10:29 AM
Disable Bridge-port
6-27
The attributes of port #1 of bridge #0 are displayed as follows:
bridge #0 port #1 STP Attributes:
====================================
Bridge-port
Bridge-port
Bridge-port
Bridge-port
Bridge-port
Bridge-port
Bridge-port
Bridge-port
Priority= 128
State= forwarding
Path Cost= 100
Designated Root= 800000c0da1800a0
Designated Cost= 0
Designated Bridge= 800000c0da1800a0
Designated port= 8001
Forward Transitions= 1
Figure 6-10 Bridge-port STP Attributes Display.
Disable Bridge-port
Disable and enable a bridge-port for a specified bridge for management.
Table 6-37 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[3] port
[4] status
Enter
Result
1 Bridge number {0-3}
(D)isables or (e)nables this
bridge-port for management.
2 Bridge-port Number {1-5}
3 D(isable)/E(nable)
Example
Enter: [3] [4] [3] [4] 0 1 D
Disables bridge-port 1 on bridge 0.
Update Bridge-port
STP parameters
Update Bridge-portpriority
Update bridge-port STP parameters: bridge-port-priority and
bridge-path-cost (see “Management Bridge Parameters” on page 11-8
for more information about the STP parameters).
Update the STP parameter bridge-port-priority for a specified bridge.
abtthgde.book Page 28 Tuesday, June 23, 1998 10:29 AM
6-28
CHAPTER 6: FAST ETHERNET AND BRIDGE MANAGEMENT TASKS
Table 6-38 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[3] port
[2] priority
Enter
Result
1 Bridge number {0-3}
The STP parameter
bridge-port-priority for this
bridge-port is updated.
2 Bridge-port Number {1-5}
3 Bridge-port-priority
Example
Enter: [3] [4] [3] [2] 0 1 128
The bridge-port-priority for port #1 of bridge #0 is set to 128.
Update
Bridge-path-cost
Update the STP parameter bridge-path-cost for a specified bridge.
Table 6-39 Task Actions
Menu
Sequence
[3] bridge
[4] stp
[3] port
[3] cost
Enter
Result
1 Bridge number {0-3}
The STP parameter
bridge-path-cost for this
bridge-port is updated.
2 Bridge-port Number {1-5}
3 Bridge-path-cost
Example
Enter: [3] [4] [3] [3] 0 1 100
The bridge-path-cost for port #1 of bridge #0 is set to 100.
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
7
MANAGING ATM RESOURCES
This chapter contains detailed descriptions of common management
tasks for the internal ATM port of the 7600 Card. Please see “Bridges in
the 7600 Card” on page 12-10 for general background material
concerning how the internal ATM port connects a bridge to the ATM
network in the 7600 Card.
The following internal ATM port management tasks are covered:
Manage ATM port
Q
Display ATM Port Attributes and Statistics
Q
Enable/Disable ATM Port Admin Status
Manage Bridge ATM addresses
Q
Display Bridge ATM address
Q
Update Bridge ATM Address
Manage Traffic Management
Q
Display TM Configuration
Q
Enable TM
Q
Display TM Clients
Q
Add TM Client
Q
Remove TM Client
Update ATM parameters
Q
Update UNI Version
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
7-2
CHAPTER 7: MANAGING ATM RESOURCES
Display ATM Port
Attributes and
Statistics
Displays the internal ATM port attributes and statistics (refer to Table 7-2)
Table 7-1 Task Actions
Menu
Sequence
[4] atm
[1] display
Enter
Result
None
Internal ATM port attributes and
statistics are displayed
Table 7-2 ATM Port Attributes and Statistics
Parameter
Description
Admin Status
The port status (“up” or “down”) defined
administratively using the Administration Console or
SNMP Manager. If the port is administratively down, it
will stay operationally down.
Oper Status
The operational status of the port (“up” or “down”).
A down status may be caused by the port being
administratively down.
In Octets (ATM Layer)
All octets received on the ATM port to the ATM layer
excluding Physical layer discards.
In Ucast (ATM Layer)
All cells received on the ATM port to the ATM layer
excluding Physical and ATM layer discards.
In Octets (AAL5 Layer)
All octets received on the ATM port to the AAL5 layer
excluding Physical and ATM layer discards.
In Ucast (AAL5 Layer)
All AAL5 frames received on the ATM port excluding
Physical, ATM and AAL5 layer discards.
Out Ucast (AAL5 Layer)
All AAL5 frames transmitted from the AAL5 layer
including AAL5, ATM and Physical layer discards.
Example
Enter: [4] [1]
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Display Bridge ATM address
7-3
The following sample ATM statistics report is displayed.
------------------------------------------------------------------------------------
ATM port:
=========
Admin Status : Up
Oper Status : Up
UNI Version
3.0
ATM Layer statistics:
--------------------In Octets
: 2619649815
In Ucast
:
49427355
AAL5 Layer statistics:
---------------------In Octets
: 2372513040
In Ucast
:
24705762
Out Ucast
:
25826096
-------------------------------------------------------------------
Figure 7-1 ATM Statistics Report Display.
Display Bridge ATM
address
Displays the current ATM addresses of the bridges.
Table 7-3 Task Actions
Menu
Sequence
[4] atm
[2] address
[1] display
Enter
Result
None
ATM addresses of the bridges are
displayed
Table 7-4 ATM Address Fields
Field
Description
Bridge
The bridge number.
ATM Address
The ATM address assigned to the bridge.
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
7-4
CHAPTER 7: MANAGING ATM RESOURCES
Table 7-4 ATM Address Fields
Field
Description
Source
The source of the ATM addresses:
Q
Automatically assigned by ILMI
Q
Manually assigned and saved in flash memory
In order to use ILMI automatically, this value should not
be assigned manually.
State (in ILMI)
State of the ATM address within ILMI. If no address has
been manually assigned, ILMI is automatically used. In
this case, it should normally be in the Registered state.
Example
Enter: [4] [2] [1]
The following is a sample ATM address display:
-------------------------------------------------------------------|Bridge|
ATM Address
|Source|State
|
|
|
|
| (in ILMI) |
+------+----------------------------------------+------+-----------+
| 0
|4700000009000000000000000000c0da18050c00| ILMI |*REGISTERD*|
--------------------------------------------------------------------
Figure 7-2 ATM Address Display
Update Bridge ATM
Address
Enter the bridge number and the ATM address (or “!” to invalidate the
ATM address) to update the local ATM address. An ATM address entered
by this command will override the ILMI address registration for the
specified bridge. When you change the ATM address manually it must be
coordinated with the ATM switch. Use the invalidate command (“!”) to
reset the ATM address, so as to restore the automatic ILMI address
registration for the specified bridge.
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Display TM Configuration
7-5
Table 7-5 Task Actions
Menu
Sequence
[4] atm
[2] address
[4] change
Enter
Result
1 Bridge Number {0-3}
Q
ATM address: Updates ATM
address of the bridges.
Q
“!”: Restores the automatic ILMI
address registration for this
bridge.
2 ATM Address or “!”
Example
Enter: [4] [2] [4] 0!
Restores the automatic ILMI address registration for bridge #0.
Display TM
Configuration
Displays the Traffic Management configuration. Refer to Chapter 13 for
more information about Traffic Management in the 7600 Card.
Table 7-6 Task Actions
Menu
Sequence
[4] atm
[4] tm
[1] display
Enter
Result
None
The Traffic Management
configuration is displayed.
Example
.
Enter: [4] [4] [1]
The following is a sample Traffic Management configuration display:
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
7-6
CHAPTER 7: MANAGING ATM RESOURCES
--------------------------------------------------------Traffic Management Configuration
TM State is DISABLED.
TM TRAM update is DISABLED.
Dual rate mechanism is ENABLED.
Default profile
is 1
Default profile for single users
is 2
Operational profile
is 3
Operational profile for single users
is 4
---------------------------------------------------------
Figure 7-3 Traffic Management configuration display
Enable TM
Enable Traffic Management operation. The application of this menu item
toggles TM operation on and off.
Table 7-7 Task Actions
Menu
Sequence
[4] atm
[4] tm
[2] enable
Enter
Result
None
The Traffic Management
configuration is displayed.
Example
.
Enter: [4] [4] [2]
The state of TM is changed from enabled to disabled and vice versa.
Display TM Clients
Display Traffic Management remote Client Database. The database
entries are listed in the following table.
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Display TM Clients
7-7
Table 7-8 Characteristics of TM Remote Client Database
Characteristic
Range
Entry
1-64
Default
Meaning
TM enabled
Y/N
Y
TM enable flag
DD connection
Y/N
Y
Direct-data connection
Index of Client in database
Remote client ATM
address
ATM address of client in
database
Profile
1-32
3
Index of lookup table used
to determine data
transmission rates
TM Peak rate
0-1.55e
+08
1.55e +08
Peak data transmission rate
in bps
Table 7-9 Task Actions
Menu
Sequence
[4] atm
[4] tm
[3] client
[1] display
Enter
Result
None
The Traffic Management remote
Client Database is displayed.
Enter: [4] [4] [3] [1]
The TM remote Client Database is displayed as follows:
--------------------------------------------------------TM Remote Client Data Base
Entry: 1
TM is: ENABLE
Connection Type: DD
ATM address: 47.00.00.00.11.22.33.44.55.66
Profile: 3
TM rate bps: 1.55e +08
---------------------------------------------------------
Figure 7-4 TM Remote Client Database Display
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
7-8
CHAPTER 7: MANAGING ATM RESOURCES
Add TM Client
Add Traffic Management client to remote Client Database. For more
information see “Display TM Clients” on page 7-6.
Table 7-10 Task Actions
Menu
Sequence
[4] atm
[4] tm
[3] client
[2] add
Enter
Result
1 ATM address
Client is added to the Traffic
Management remote Client
Database.
2 Profile (1-32)
3 TM peak rate
4 TM enable (Y/N)
Example
.
Enter: [4] [4] [3] [2] + [respond to prompts]
Characteristics for the new client in the Traffic Management remote
Client Database are requested as follows:
Remote client ATM address:
Profile (1-32)
TM Peak rate:
TM enable (Y/N)?:
DD connection
Entry added
Remove TM Client
Remove Traffic Management client from remote Client Database.
Table 7-11 Task Actions
Menu
Sequence
[4] atm
[4] tm
[3] client
[3] remove
Enter
Result
Entry (1-64, 0=all)
Client with specified entry number
is removed from the Traffic
Management remote Client
Database.
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
Update UNI Version
7-9
Example
.
Enter: [4] [4] [3] [3] 1
Entry #1 is removed from the remote Client Database
Update UNI Version
Choose between working with UNI 3.0 and UNI 3.1 versions.
Table 7-12 Task Actions
Menu
Sequence
[4] atm
[6] uni
Enter
Result
3.0 or 3.1
The selected version is saved in flash
Example
Enter: [4] [6]
The following screen prompt is displayed. The currently active version is
displayed after the colon. Either press return to keep the same version or
type in the other version.
Select UNI version (3.0, 3.1) : 3.0
The selected version is saved in flash.
Enable/Disable ATM
Port Admin Status
Enable or disable the ATM port for all bridges. Setting the port to
“down” will cause the port to be (and stay) operationally down. Specify
“up” to enable the ATM port or “down” to disable the ATM port.
Table 7-13 Task Actions
Menu
Sequence
[4] atm
[8] status
Enter
Result
(U)p/(D)own
Q
Up: Enables ATM port
Q
Down: Disables ATM port
Example
Enter: [4] [8] U
abtthgde.book Page 10 Tuesday, June 23, 1998 10:29 AM
7-10
CHAPTER 7: MANAGING ATM RESOURCES
ATM port is enabled. The following screen message is displayed:
Context #0 Event: ATM port Link Up.
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
8
MANAGING LAN EMULATION
CLIENTS
This chapter contains detailed descriptions of common management
tasks for the LAN Emulation Client of the 7600 Card. For a general
discussion of LAN Emulation, see “LAN Emulation Overview” on page
12-5 and see “Bridges in the 7600 Card” on page 12-10 for material
describing how the LAN Emulation Client connects a bridge to the ATM
network Emulated LAN in the 7600 Card.
The following LAN Emulation Client (LEC) management tasks are
covered:
Display statistics
Q
Display LEC Statistics
Q
Display LEC Control-frame Statistics
Q
Reset LEC Control-frame Statistics
Manage configuration parameters
Q
Display Current LEC Configuration
Q
Update LECS Address
Q
Update ELAN Name
Q
Update LES Address
Manage operational parameters
Q
Display LEC Operational Parameters
Q
Update LEC Operational Parameters
Q
Control-timeout
Q
VCC-timeout-period
Q
Aging-time
Q
Forward-delay-time
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
8-2
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
Q
Topology-change- flag
Q
Expected LE_ARP response-time
Q
Flush-timeout
Q
Path-switching- delay
Q
Connection- completion-timer
Manage data-frame parameters
Q
Display LEC
Statistics
Update Unknown Unicast-flood- Mode
Displays the LAN Emulation Client (LEC) connection state and statistics for
the specified bridge (refer to Table 8-2). For more information see “Data
Transmission over an ELAN” on page 12-15.
Table 8-1 Task Actions
Menu
Sequence
[5] le
[1] display
Enter
Result
1 Bridge Number {0-3}
LAN Emulation Client (LEC)
connection state and statistics for
the specified bridge are displayed.
Table 8-2 LEC Attributes
Attribute
Description
State
The connection state of the LEC is one of the following:
Q
Initial State
Q
LECs Connect
Q
Configure
Q
Join
Q
Bus Connect
Q
Operational
In* Octets
All octets of LE frames received by the LEC.
In Ucast
Unicast LE frames received by the LEC targeted to the
device, excluding Physical, ATM and AAL5 layer discards.
In Mcast
Multicast LE frames received by the LEC targeted to the
device, excluding Physical, ATM and AAL5 layer discards.
In Bcast
Broadcast LE frames received by the LEC targeted to the
device, excluding Physical, ATM and AAL5 layer discards.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Display LEC Statistics
8-3
Table 8-2 LEC Attributes (continued)
Attribute
Description
In Discards
All LE frames received by the LEC, discarded for internal
reasons, for example, queues.
In Errors
All LE frames received by the LEC, discarded due to errors.
In Unknown
All LE frames received by the LEC, discarded due to
unknown protocols.
Out Octets
All octets of LE frames transmitted by the LEC.
Out Ucast
Unicast LE frames transmitted from the LEC initiated by the
device, including LE, AAL5, ATM and Physical layer discards.
Out Mcast
Multicast LE frames transmitted from the LEC initiated by the
device, including LE, AAL5, ATM and Physical layer discards.
Out Bcast
Broadcast LE frames transmitted from the LEC initiated by
the device, including LE, AAL5, ATM and Physical layer
discards.
Out Discards
All LE frames initiated by the device, discarded from being
transmitted out the LEC for internal reasons, for example,
queues.
Out Errors
All LE frames initiated by the device, discarded from being
transmitted out the LEC due to errors.
* In - from the ATM
Example
Enter: [5] [1] 0
The following connection state and statistics for the bridge #0 are
displayed:
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
8-4
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
----------------------------------------------------------------LEC of bridge 0:
=================
State: Operational
Statistics:
----------In Octets
:
237251304
Out Octets
:
0
In Ucast
:
0
Out Ucast
:
0
In Mcast
:
0
Out Mcast
:
0
In Bcast
:
0
Out Bcast
:
1
In Discards :
0
Out Discards :
0
In Errors
:
0
Out Errors
:
0
In Unknown :
0
-----------------------------------------------------------------
Figure 8-1 LEC Attributes Display
Display Current LEC
Configuration
Displays the current LEC configuration and status, including LECS, LES
and BUS information (refer to Table 8-4). For general information about
LECs see “LAN Emulation Overview” on page 12-5.
Table 8-3 Task Actions
Menu
Sequence
[5] le
[2] config
[1] display
Enter
Result
1 Bridge Number {0-3}
Displays the current LEC
configuration and status for the
specified bridge.
Table 8-4 LEC Configuration and Status Information
LECS Information
Description
ATM Address
The ATM address of the LECS.
Config VCC
VPI/VCI values of the configuration-direct VCC.
LES Information
Description
ELAN Name
The name of the Emulated LAN (ELAN) to which the
LEC belongs.
LEC ID
The LAN Emulation Client (LEC) identifier.
ATM Address
ATM address of the LES.
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Display Current LEC Configuration
8-5
Table 8-4 LEC Configuration and Status Information (continued)
Control Direct VCC
VPI/VCI values of the control-direct VCC from the LEC
to the LES.
Control Distribute VCC
VPI/VCI values of the control-distribute VCC from the
LES to the LEC.
BUS Information
Description
ATM Address
ATM address of the BUS.
Multicast Send VCC
VPI/VCI values of the multicast-send VCC from the LEC
to the BUS.
Multicast Forward VCC
VPI/VCI values of the multicast-forward VCC from the
BUS to the LEC.
Example
Enter: [5] [2] [1] 0
The following LEC configuration and status for the bridge #0 are
displayed.
---------------------------------------------------------------| LECS via ILMI mode is : Disabled
| LECS info :
| ATM address: not valid
| Config VCC
(VPI/VCI) : not valid
+-------------------------------------------------------------+
| LES info :
| ELAN name : elan0_0 lec id : 6
| ATM address: 4700000009000000000000000000c0da60000000
| Control Direct VCC
(VPI/VCI) : 0 / 40
| Control Distribute VCC(VPI/VCI) : 0 / 36
+-------------------------------------------------------------+
| BUS info :
| ATM address: 4700000009000000000000000000c0da60000000
| Multicast Send VCC
(VPI/VCI) : 0 / 41
| Multicast Forward VCC (VPI/VCI) : 0 / 37
----------------------------------------------------------------
Figure 8-2 LEC Configuration and Status Display
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
8-6
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
Update LECS
Address
Enter the bridge number and ATM address (or “!” to invalidate the
address) to update the LECS address. For general information about LECS
see “LAN Emulation Overview” on page 12-5.
Table 8-5 Task Actions
Menu
Sequence
[5] le
[2] config
[4] cs-addr
Enter
Result
1 Bridge Number {0-3}
Q
ATM address: Updates the
specified LECS ATM address for
specified bridge
Q
“!”: Invalidates the LECS ATM
address
2 LECS ATM address or “!”
Example
Enter: [5][2][4] 0 4700000009000000000000000000c0da60000000
The LECS address for the LEC of bridge #0 is entered.
Update ELAN Name
Enter: the bridge number and ELAN name (or “!” to invalidate the name)
to update the ELAN name. For general information about LECs see “LAN
Emulation Overview” on page 12-5.
Table 8-6 Task Actions
Menu
Sequence
[5] le
[2] config
[5] elan-name
Enter
Result
1 Bridge Number {0-3}
Q
ELAN name: Updates the
specified ELAN name for
specified bridge to flash
Q
“!”: Invalidate the ELAN
name
2 ELAN name or “!”
Example
Enter: [5][2][5] 0 ELAN_0
The ELAN name for the LEC of bridge #0 is entered.
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Update LES Address
Update LES Address
8-7
Enter the bridge number and ATM address (or ! to invalidate the address)
to update the LES address. For general information about LECs see “LAN
Emulation Overview” on page 12-5.
Table 8-7 Task Actions
Menu
Sequence
[5] le
[2] config
[6] les-addr
Enter
Result
1 Bridge Number {0-3}
Q
ATM address: Update the
specified LES ATM address for
specified bridge
Q
“!”: Invalidates the LES ATM
address
2 LES ATM address or “!”
Example
Enter: [5][2][4] 0 4700000009000000000000000000c0da60000000
The LES address for the LEC of bridge #0 is entered.
Enable LECS
Address via ILMI
Enable the option to obtain the LECS address via the ILMI. Each
application of the command toggles the option on or off. The change will
take place after the next reset. For general information about LECSs see
“LAN Emulation Overview” on page 12-5.
Table 8-8 Task Actions
Menu
Sequence
[5] le
[2] config
[7] mode-lecs
Enter
Result
None
Q
The option to obtain the
LECS address via ILMI is
toggled on or off. The
default is off.
Example
Enter: [5][2][7]
The option to obtain the LECS address via ILMI is toggled on or off.
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
8-8
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
Display LEC
Operational
Parameters
Displays the LEC operational parameters for the specified bridge (refer to
Table 8-10). For more information see “LEC Parameters” on page 12-16.
Table 8-9 Task Actions
Menu
Sequence
[5] le
[3] operational
[1] display
Enter
Result
1 Bridge Number {0-3}
LEC operational information for
the specified bridge is displayed.
Table 8-10 LEC Operational Parameters
LEC Parameter
Description
Control-timeout
Timeout period used for timing out most
request/response control frame interactions.
VCC-timeout-period
An LEC should release any Data Direct VCC that has
not been used to transmit or receive any data frames
for the length of the VCC-timeout-period.
Aging-time
The maximum time that an LEC will maintain an entry
in its LE_ARP cache in the absence of a verification of
that relationship.
Forward-delay-time
The maximum time that an LEC will maintain an entry
for a non-local MAC address in its LE_ARP cache in the
absence of a verification of that relationship, as long as
the topology-change-flag is true.
Expected LE_ARP Resp
Time
The maximum time that the LEC expects an LE_ARP
request/response cycle to take. Used for retries and
verifies.
Topology-change-flag
Boolean indication that the LEC is using the
forward-delay-time instead of aging-time to age
non-local entries in its LE_ARP cache.
Flush-timeout
Time limit to wait to receive an LE_FLUSH response
after the request has been sent, before taking recovery
action.
Path-switching-delay
The time since sending a frame to the BUS after which
the LEC may assume that the frame has been either
discarded or delivered to the recipient.
Connection-completiontimer
In Connection Establishment this is the time period in
which data or a READY_IND message is expected from
a Calling Party.
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
Update LEC Operational Parameters
8-9
Example
Enter: [5][3][1] 0
The LEC operational information for the LEC of bridge #0 is displayed as
follows:
---------------------------------------------------------Control Timeout= 120
VCC Timeout= 1200
Aging Time= 300
Forward Delay Time= 15
Expected LE ARP Resp Time= 1
Topology change flag= OFF
Flush Timeout= 4
Path Switching Delay= 6
Connection Completion Timer= 4
----------------------------------------------------------
Figure 8-3 LEC Operational Parameters Display
Update LEC
Operational
Parameters
Control-timeout
Update the LEC operational parameters: control-timeout,
VCC-timeout-period, aging-time, forward-delay-time,
topology-change-flag, expected LE_ARP response-time, flush-timeout,
path-switching-delay and connection-completion-timer. For more
information see “LEC Parameters” on page 12-16.
Enter the bridge number and control-timeout value to update the
control-timeout parameter in seconds.
Table 8-11 Task Actions
Menu
Sequence
[5] le
[3] operational
[2] control
Enter
Result
1 Bridge Number {0-3}
The control-timeout parameter
is updated for the specified
bridge.
2 Control-timeout {10-300}
Example
Enter: [5][3][2] 0 100
abtthgde.book Page 10 Tuesday, June 23, 1998 10:29 AM
8-10
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
The control-timeout parameter for the LEC of bridge #0 is updated to
100 seconds.
VCC-timeout-period
Enter the bridge number and control-timeout value to update the
VCC-timeout-period parameter.
Table 8-12 Task Actions
Menu
Sequence
[5] le
[3] operational
[3] vcc
Enter
Result
1 Bridge Number {0-3}
The VCC-timeout-period
parameter is updated for the
specified bridge.
Minimum=None specified
Default=20 minutes
Maximum=Unlimited
2 VCC-timeout-period
{minutes}
Example
Enter: [5][3][3] 0 20
The VCC-timeout-period parameter for the LEC of bridge #0 is updated
to 20 minutes.
Aging-time
Enter the bridge number and aging-time value to update the LEC
aging-time parameter.
Table 8-13 Task Actions
Menu
Sequence
[5] le
[3] operational
[4] aging
Enter
Result
1 Bridge Number {0-3}
The LEC aging-time parameter
is updated for the specified
bridge.
2 LEC aging-time {10-300}
Example
Enter: [5][3][4] 0 250
The aging-time parameter for the LEC of bridge #0 is updated to 250
seconds.
abtthgde.book Page 11 Tuesday, June 23, 1998 10:29 AM
Update LEC Operational Parameters
Forward-delay-time
8-11
Enter the bridge number and forward-delay-time value to update the LEC
forward-delay-time parameter.
Table 8-14 Task Actions
Menu
Sequence
[5] le
[3] operational
[5] forward
Enter
Result
1 Bridge Number {0-3}
The LEC forward-delay-time
parameter is updated for the
specified bridge.
2 LEC forward-delay-time
{4-30}
Example
Enter: [5][3][5] 0 20
The forward-delay-time parameter for the LEC of bridge #0 is updated to
20 seconds.
Topology-changeflag
Enter the bridge number and topology-change-flag value to update the
LEC topology-change-flag parameter.
Table 8-15 Task Actions
Menu
Sequence
[5] le
[3] operational
[6] topology
Enter
Result
1 Bridge Number {0-3}
The LEC topology-change-flag
parameter is updated for the
specified bridge.
2 LEC topology-change-flag
Example
Enter: [5][3][6] 0 ON
The topology-change-flag parameter for the LEC of bridge #0 is updated
to ON.
Expected LE_ARP
response-time
Enter the bridge number and expected LE_ARP response-time value to
update the LEC expected LE_ARP response-time parameter.
abtthgde.book Page 12 Tuesday, June 23, 1998 10:29 AM
8-12
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
Table 8-16 Task Actions
Menu
Sequence
[5] le
[3] operational
[7] arp
Enter
Result
1 Bridge Number {0-3}
The LEC expected LE_ARP
response-time parameter is
updated for the specified
bridge.
2 LEC expected LE_ARP
response-time {1-30}
Example
Enter: [5][3][7] 0 2
The expected LE_ARP response-time parameter for the LEC of bridge #0
is updated to 2 seconds.
Flush-timeout
Enter the bridge number and flush-timeout value to update the LEC
flush-timeout parameter.
Table 8-17 Task Actions
Menu
Sequence
[5] le
[3] operational
[8] flush
Enter
Result
1 Bridge Number {0-3}
The LEC flush-timeout
parameter is updated for the
specified bridge.
2 LEC flush-timeout {1-4}
Example
Enter: [5][3][8] 0 3
The flush-timeout parameter for the LEC of bridge #0 is updated to 3
seconds.
Path-switchingdelay
Enter the bridge number and path-switching-delay value to update the
LEC path-switching-delay parameter.
Table 8-18 Task Actions
Menu Sequence
Enter
Result
[5] le
[3] operational
[9] path switch
1 Bridge Number {0-3}
The LEC path-switching-delay
parameter is updated for the
specified bridge.
2 LEC path-switching-delay
{1-8}
abtthgde.book Page 13 Tuesday, June 23, 1998 10:29 AM
Update LEC Operational Parameters
8-13
Example
Enter: [5][3][9] 0 5
The path-switching-delay parameter for the LEC of bridge #0 is updated
to 5 seconds.
Connectioncompletion-timer
Enter the bridge number and connection-completion-timer value to
update the LEC connection-completion-timer parameter.
Table 8-19 Task Actions
Menu Sequence
Enter
Result
[5] le
[3] operational
[10] completion
1 Bridge Number {0-3}
The LEC connectioncompletion-timer parameter is
updated for the specified
bridge.
2 LEC connectioncompletion-timer {1-10}
Example
Enter: [5][3][10] 0 7
The connection-completion-timer parameter for the LEC of bridge #0 is
updated to 7 seconds.
abtthgde.book Page 14 Tuesday, June 23, 1998 10:29 AM
8-14
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
Display LEC
Control-frame
Statistics
Displays the LEC control frame statistics for the specified bridge number
(refer to Table 8-21). For more information see “Emulated LAN
Connections” on page 12-7.
Table 8-20 Task Actions
Menu
Sequence
[5] le
[4] lec-control
Enter
Result
Bridge Number {0-3}
LEC control frame statistics for
the specified bridge are
displayed.
Table 8-21 LEC Control Frame Statistics
Parameter
Description
Arp (In Requests)
Number of LE_ARP requests received by the LEC.
LE_ARP requests are sent to determine the ATM
address associated with a given MAC address.
Narp (In Requests)
Number of negative LE_ARP requests received by the
LEC. Negative LE_ARP requests are sent by an LE client
to advertise changes in remote address bindings.
Topology (In Requests)
Number of topology change requests received by the
LEC.
Flush (In Requests)
Number of flush requests received by the LEC.
Config (In Responses)
Number of configuration responses received by the
LEC.
Join (In Responses)
Number of join responses received by the LEC.
Register (In Responses)
Number of register responses received by the LEC.
Unregister (In Responses)
Number of unregister responses received by the LEC.
Arp (In Responses)
Number of LE_ARP responses received by the LEC.
Arp Eavesdrop (In
Responses)
Number of LE_ARP responses that were not meant for
the LEC that were received and learned from.
Ready Query (In Ready
Frames)
Number of READY_QUERY messages received by the
LEC.
Ready Ind (In Ready
Frames)
Number of READY_IND messages received by the LEC.
Msg Error (In Errors)
Number of errored LE control frames received by the
LEC.
Wrong Type (In Errors)
Number of LE control frames of the wrong type
received by the LEC.
abtthgde.book Page 15 Tuesday, June 23, 1998 10:29 AM
Display LEC Control-frame Statistics
8-15
Table 8-21 LEC Control Frame Statistics (continued)
Parameter
Description
Not Ours (In Errors)
Number of LE control frames not intended for the LEC
received.
Not Learn (In Errors)
Number of LE control frames which were discarded
because the LEC was not in an appropriate state.
Config (Out Requests)
Number of configuration requests sent by the LEC.
Join (Out Requests)
Number of join requests sent by the LEC.
Register (Out Requests)
Number of register requests sent by the LEC.
Unregister (Out Requests)
Number of unregister requests sent by the LEC.
Arp (Out Requests)
Number of LE_ARP requests sent by the LEC.
Narp (Out Requests)
Number of negative LE_ARP requests sent by the LEC.
Topology (Out Requests)
Number of topology change requests sent by the LEC.
Flush (Out Requests)
Number of flush requests sent by the LEC.
Arp (Out Responses)
Number of LE_ARP responses sent by the LEC.
Flush (Out Responses)
Number of flush responses sent by the LEC.
Ready Query (Out Ready
Frames)
Number of READY_QUERY messages sent by the LEC.
Ready Ind (Out Ready
Frames)
Number of READY_IND messages sent by the LEC.
Bad Status (Out Errors)
Number of bad status LE control frame responses sent
by the LEC.
Bad State (Out Errors)
Number of frames not sent by the LEC because it was
not in the appropriate state to send them.
Gen Error (Out Errors)
Number of LE control frames not sent due to internal
errors.
Example
Enter: [5][4] 0
The LEC control frame statistics for the bridge #0 are displayed as follows:
abtthgde.book Page 16 Tuesday, June 23, 1998 10:29 AM
8-16
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
-------------------------------------------------------------------Statistics for LE Client of bridge 0:
=====================================
In Requests:
-----------Arp
:
Topology
:
25
0
In Responses:
------------Config
:
Register
:
Arp
:
Flush
:
Narp
Flush
0
0
24
14
In Ready frames:
---------------Ready Query :
In Errors:
---------Msg Error
Not Ours
Out Requests:
------------Config
:
Register
:
Arp
:
Topology :
Out Responses:
-------------Arp
:
0
Wrong Type
Not Learn
0
1
:
0
3
:
1
:
0
:
1
37
0
Join
:
Unregister
:
Narp
:
Flush
:
0
14
25
Flush
9
0
Out Ready frames:
----------------Ready Query :
Out Errors:
----------Bad Status
Gen Error :
Ready Ind
34
0
9
Join
:
Unregister
Arp Eavesdrop
:
0
:
:
:
:
:
1
1
0
0
Ready Ind
0
Bad State
:
:
2
:
0
abtthgde.book Page 17 Tuesday, June 23, 1998 10:29 AM
Reset LEC Control-frame Statistics
8-17
Figure 8-4 LEC Control Frame Statistics Display.
Reset LEC
Control-frame
Statistics
Resets the LEC control-frame statistics to zero for the specified bridge. For
more information see “Emulated LAN Connections” on page 12-7.
Table 8-22 Task Actions
Menu
Sequence
[5] le
[5] reset
Enter
Result
Bridge Number {0-3}
LEC control frame statistics are reset
to zero for the selected bridge.
Example
Enter: [5][5] 0
The LEC control frame statistics are reset to zero for bridge #0.
Update Unknown
Unicast-floodMode
Updates the unknown unicast-flood-mode for the specified bridge. The
change takes place at the next reset. For more information see
“Unknown Unicast Frames” on page 12-15.
Table 8-23 Task Actions
Menu
Sequence
[5] le
[6] flood
Enter
Result
1 Bridge Number {0-3}
Q
N<ot Flood> - No unicast frames
are sent to the BUS for the
specified bridge
Q
Req <Arp> - Unicast frames are
sent to the BUS for the specified
bridge, until the LE_ARP request
is sent
Q
Res <pArp> - Unicast frames are
sent to the BUS for the specified
bridge, until the LE_ARP
response is received
2 Unicast flood mode:
Q
N<ot Flood>
Q
Req <Arp>
Q
Res <pArp>
Example
Enter: [5][6] 0 N
abtthgde.book Page 18 Tuesday, June 23, 1998 10:29 AM
8-18
CHAPTER 8: MANAGING LAN EMULATION CLIENTS
No unicast frames are sent to the BUS for the specified bridge and the
following message is displayed.
The LE flood mode for Bridge #0 is now: NotFlood
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
9
SETTING NETWORK PARAMETERS
This chapter contains detailed descriptions of common management
tasks for setting up your 7600 Card to work with an SNMP manager (for
example, Transcend ATM Manager), TFTP or Telnet (if working through
the CELLplex 7000 unit). An IP address, subnet mask and Default
Gateway must be defined in the bridge to which the SNMP manager is
connected.
The IP address is used to identify the 7600 Card within the network. The
SNMP and TFTP use this address when connecting to the 7600 Card.
The Network Management Station (NMS) IP address is defined in the
7600 Card to enable the unit to send SNMP traps to the NMS.
The following management tasks are covered:
Manage IP parameters
Q
Display Current IP Configuration
Q
Update IP Address
Q
Update Default Gateway
Q
Update Subnet Mask
Manage SNMP parameters
Q
Display SNMP Configuration
Q
Update NMS IP Address
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
9-2
CHAPTER 9: SETTING NETWORK PARAMETERS
Display Current IP
Configuration
Displays the current IP configuration for each of the bridges (refer to
Table 9-2).
Table 9-1 Task Actions
Menu Sequence
Enter
Result
[7] management
[1] ip
[1]display
None
Current IP configuration
parameters are displayed for
all bridges
Table 9-2 IP Configuration Information
Parameter
Description
Bridge
The number of the bridge (virtual network).
IP addr
The IP address of the bridge.
Subnet Mask
The IP address bit mask of the subnet where the specified bridge
is located. Applying the subnet mask on the IP address
(depending on its class - A, B or C) determines the IP address;
subnet address.
Def. Gateway
The IP address of the default gateway (router) connected to the
specified bridge. The default gateway is only required if routers
are being used in the network. There can be only one router
defined per virtual network (Bridge).
Example
Enter: [7] [1] [1]
The following is displayed:
-------------------------------------------------------------------Bridge: 0
IP addr.
: 100.0.0.1
Subnet Mask: 255.255.255.0
Def. Gateway: 100.0.0.55
Bridge: 1
IP addr.
: 100.0.2.2
Subnet Mask: 255.255.255.0
Def. Gateway: 100.0.2.99
--------------------------------------------------------------------
Figure 9-1 IP Configuration Display.
Update IP Address
Enter the bridge number and the new IP Address to update the IP
Address for the specified bridge.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Update Default Gateway
9-3
Table 9-3 Task Actions
Menu Sequence
Enter
Result
[7] management
[1] ip
[4] ip-addr
1 Bridge Number {0-3}
IP Address is updated for
specified bridge.
2 IP Address
Example
Enter: [7] [1] [4] 0 100.0.2.2
The IP Address for bridge #0 is updated to 100.0.2.2
Update Default
Gateway
Enter the bridge number and the new Default Gateway to update the
Default Gateway for the specified bridge.
Table 9-4 Task Actions
Menu Sequence
Enter
Result
[7] management
[1] ip
[5] gateway
1 Bridge Number {0-3}
Default Gateway is
updated for specified
bridge.
2 Default Gateway
Example
Enter: [7] [1] [5] 0 100.0.2.88
The Default Gateway for bridge #0 is updated to 100.0.2.88
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
9-4
CHAPTER 9: SETTING NETWORK PARAMETERS
Update Subnet
Mask
Enter the bridge number and the new subnet mask to update the subnet
mask for the specified bridge.
Example
Table 9-5 Task Actions
Menu Sequence
Enter
Result
[7] management
[1] ip
[6] mask
1 Bridge Number {0-3}
Subnet Mask is updated for
specified bridge.
2 Subnet Mask
Enter: [7] [1] [6] 0 255.255.255.0
The Subnet Mask for bridge #0 is updated to 255.255.255.0
Display SNMP
Configuration
Displays the SNMP configuration.
Table 9-6 Task Actions
Menu Sequence
Enter
Result
[7] management
[2] snmp
[1] display
None
The SNMP configuration is
displayed.
Table 9-7 SNMP Configuration Information
Parameter
Description
Bridge
The number of the bridge (virtual network).
Default NMS
The IP address for the default Network Management Station
(NMS) for the specified bridge.
Example
Enter: [7] [2] [1]
The SNMP configuration is displayed as follows:
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Update NMS IP Address
9-5
-------------------------------------------------------Bridge: 0
Default NMS: 100.0.0.92
Bridge: 1
Default NMS: 100.0.2.93
--------------------------------------------------------
Figure 9-2 SNMP Configuration Display.
Update NMS IP
Address
Enter the bridge number and the new NMS IP address to update the
Network Management Station (NMS) IP address, for receiving SNMP
traps.
Table 9-8 Task Actions
Menu Sequence
Enter
Result
[7] management
[2] snmp
[2] nms-addr
1 Bridge Number {0-3}
IP address is updated for
specified bridge.
2 IP address
Example
Enter: [7] [2] [2] 0 100.0.0.92
The IP address for bridge #0 is updated to 100.0.0.92
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
10
MANAGING SYSTEM FUNCTIONS
This chapter contains detailed descriptions of common management
tasks for the system functions of the 7600 Card.
The following system functions tasks are covered:
Manage software and hardware configuration
Q
Display Software Version
Q
Display Software Download Status
Q
Download Software from Network
Q
Erase Software from Flash
Q
Download Software from Local
Q
Display Hardware Configuration
Update the system working mode and attributes
Q
Set System Configuration Mode
Q
Set Store-and- Forward Mode
.Manage timeout parameters
Q
Display Timeout Parameters
Q
Display Timeout Delays
Q
Update Hardware Timeout Delay
Q
Update Software Timeout Delay
Manage flash memory
Q
Reset Flash Memory
Update console passwords
Q
Update Read-access Password
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
10-2
CHAPTER 10: MANAGING SYSTEM FUNCTIONS
Q
Update Write-access Password
Q
Update Admin-access Password
Manage event messages
Q
Enable/Disable Event Messages
Resetting system
Q
Display Software
Version
Reset and Reboot
Displays the current software version, revision number and date of
implementation.
Table 10-1 Task Actions
Menu
Sequence
[1] system
[1]display
Enter
Result
None
The current software version,
revision number and date of
implementation are displayed
Example
Enter: [1] [1]
The current software version, revision number and date of
implementation are displayed as follows:
-----------------------------------------------------------Software version Ver. 3.17 - Built Oct. 22 1996 17:39:57
------------------------------------------------------------
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Display Software Download Status
Display Software
Download Status
10-3
Display the status of the last TFTP software download.
Table 10-2 Task Actions
Menu
Sequence
[1] system
[9] load
[1] display
Enter
Result
None
Status of last TFTP software
download is displayed.
Example
Enter: [1] [9] [1]
Status of last TFTP software download is displayed:
Download
Software from
Network
Download the software via the network by TFTP.
Table 10-3 Task Actions
Menu
Sequence
[1] system
[9] load
[2] tftp
Enter
Result
1 Server IP address
System software is downloaded via
tftp.
2 File to be downloaded
Example
Enter: [1] [9] [2] 100.0.0.24 applic.swf
System software is downloaded via tftp.
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
10-4
CHAPTER 10: MANAGING SYSTEM FUNCTIONS
Erase Software
from Flash
Erase the software program from flash prior to downloading of the new
system software from a PC or workstation with a VT100 terminal
emulation attached directly to the 7600 Card through the emergency
serial port.
The software may be loaded without this step.
Table 10-4 Task Actions
Menu
Sequence
[1] system
[9] load
[3] local
Enter
Result
None
System software is erased from
flash.
Example
Enter: [1] [9] [3]
System software is erased from flash.
Download
Software from
Local
To load a new version of the system software locally, use the following
procedure:
1 Run the terminal emulation program, for example, PROCOMM Plus.
2 Pull out the Switch Board from the CELLplex 7000 Switch and leave it out
until the procedure is finished.
3 Connect the terminal to the internal RS-232 connector located on the
right side of the rear-mounted daughter board.
4 Reset the unit.
5 Press Shift-U. The screen should read “Monitor port = LMA”.
6 Change Baud Rate to 57600.
7 Press Enter and the prompt (>) appears.
8 Type “do” and use the terminal emulation software in binary mode to
load the 7600 Fast Ethernet Card software. The name of the 7600 file is
763171.str.
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Display Hardware Configuration
10-5
9 The file will now download. When the download is complete, a prompt
appears. Refer to the documentation of your terminal emulation for more
information on downloading files.
10 Push the Switch Board back into the CELLplex 7000 Switch.
11 Restore Baud Rate to 19200.
12 Reset the unit.
Display Hardware
Configuration
Hardware configuration information including a hardware diagnostic
report, is displayed, showing the pass/failed status of each hardware
element within the 7600 Card.
Table 10-5 Task Actions
Menu
Sequence
Enter
[1] system [2] None
status
Result
The hardware configuration and
pass/failed status of each hardware
element within the 7600 Card is
displayed.
Example
Enter: [1] [2]
The following is a sample hardware status report for one context:
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
10-6
CHAPTER 10: MANAGING SYSTEM FUNCTIONS
--------------------------------------------------------Context No. 1 Configuration
***
***
***
***
***
***
***
***
FE
FE
FE
FE
Utopia
ZipChip :
Hermon :
TM
Port #1 :
Port #2 :
Port #3 :
Port #4 :
- Slave, TRAM - 256 K, CRAM - 512 K
type ZC2+
ver 3.3
: ver 1.10
Installed
Installed
Installed
Installed
*** Context #4 diagnostics report:
*** ---------------------*** TRAM
: 256 K pass
*** CRAM
: 1024 K pass
*** SRAM
:
32 K pass
*** FRAM
: 128 K pass
*** ZipChip Diagnostic
: pass
*** TM Register Diagnostics
: pass
*** ZipChip Diagnostic
: pass
*** SEEC Diagnostics
: pass
*** Check cells chaining
: pass
*** Interrupts diagnostics : pass
*** HW Diagnostics : pass
--------------------------------------
Figure 10-1 Hardware Configuration Display
Set System
Configuration
Mode
Enter the desired system configuration mode. The default mode is the
current system configuration mode.
Table 10-6 Task Actions
Menu
Sequence
[1] system [3]
update [5]
mode
Enter
Q
L<E> (LAN Emulation)
Example
Enter: [1] [3] [5]
Result
Q
LAN Emulation - standard LAN
Emulation
The mode is saved in flash.
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Set Store-and- Forward Mode
10-7
The system configuration mode is set according to following prompt. The
current mode is displayed after the colon. To accept it press “enter”; to
change it type over the new choice and press “enter”.
Select system mode (L<E>): L
Set Store-andForward Mode
Set the desired store-and-forward mode. The mode is saved in flash. The
mode set applies to all frames arriving from all Ethernet ports and all
frames arriving from the ATM ports. This mode change takes effect only
after the next reset.
Table 10-7 Task Actions
Menu
Sequence
Enter
[1] system [3] Enter
update [6]
S<&f> or C<utthru>
s&f
Result
Q
Store & forward - the entire
frame is received before being
forwarded to its destination.
Q
Cut-through - the cells of the
frame are forwarded to their
destination before the entire
frame is received
Example
Enter: [1] [3] [6]
The store-and-forward mode is set according to following prompt. The
current mode is displayed after the colon. To accept it press “enter”; to
change it type over the new choice and press “enter”.
Select mode (S<&F>, C<utThru>): C
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
10-8
CHAPTER 10: MANAGING SYSTEM FUNCTIONS
Display Timeout
Parameters
Display the software and hardware timeout parameters. Refer to
Table 10-9 for descriptions of the timeout parameters.
Table 10-8 Task Actions
Menu
Sequence
[1] system
[3] update
[8] timeout
[1] info
Enter
Result
None
The software and hardware timeout
delays are displayed.
Table 10-9 Timeout Parameters
Name
Description
Timeout Delay
The software and hardware timeout delay in seconds
Current Time
The current time being used by the 7600 Card
Timeout Interrupts
The number of interrupts registered by the timeout
mechanism
False Interrupts
The number of false interrupts detected by the
software.
Events Captured
The number of interrupts the hardware reported
timeouts for.
Events Confirmed
The number of software confirmed Ethernet segment
timeouts.
Server Released
The number of times the server released frames
automatically without intervention by the hardware or
software.
MACE Stucked
The number of times timeouts were caused due to a
heavy load on the physical line.
Queue invalid
The number of times the frame came in on an invalid
VC.
Wait for end SW TO
The number of timeouts that occurred in the software.
Wait for end HW TO
The number of timeouts that occurred in the hardware.
Events processed
The number of hardware timeouts processed that the
software caused to discard the frame abnormally.
SW TO processed
The number of software timeouts processed that the
software caused to discard the frame abnormally.
TO from ETH
The number of frames from the Ethernet that caused
timeouts.
Server events
The number of events by Ethernet segment.
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
Display Timeout Parameters
10-9
Table 10-9 Timeout Parameters (continued)
Name
Description
Empty cell counter
The number of free cells in CRAM.
Full queues mask
The current status of the queues (12 Ethernet, 1 ATM,
and the software queue). When the bit is set, the
queue is full.
Disable SW bdcats
The number of times the software closed broadcasts
from going to it, due to a heavy load.
Enable SW bdcats
The number of times the software opened to enable
broadcasts to go to it.
Spare Cell Busy
The number of times the previous timeout was not
completed.
Spare Cell Busy (SW)
The number of times the previous software timeout
was not completed.
Number of items in output Lists each queue (12 Ethernet, 1 ATM and 1 to the
queues
software) and the number of items in waiting in each
queue.
Example
Enter: [1] [3] [8] [1]
The following is a sample timeout parameters report:
abtthgde.book Page 10 Tuesday, June 23, 1998 10:29 AM
10-10
CHAPTER 10: MANAGING SYSTEM FUNCTIONS
-----------------------------------------------------Timeout recovery process report:
-------------------------------Timeout delay
: 30 (SW: 30)
Current time
: 31494918
Timeout interrupts : 64
False interrupts
: 0
Events captured
: 0
Events confirmed
: 0
Server released
: 64
MACE stucked : 0
Queue invalid : 0
Wait for end SW TO : 0
Wait for end HW TO : 0
False alarms_1 : 0
False alarms_2 : 0
Events processed : 0
SW TO processed
: 0
TO from ETH
: 0
Server events : 0, 64, 0, 0, 0, 0, 0, 0, 0, 0
Empty cell counter : 3fe1
Full queues mask
: 0000
Disable SW bdcats
: 0000
Enable SW bdcats
: 0000
Single cell CPI > 1 : 0000
Problems :
0
Frames CPI=0
:
0
Frames CPI=0(SW)
:
0
Invalid
CPI
:
0
Invalid
CPI(SW):
0
Invalid hptr
:
0
Invalid index
:
0
Spare Cell Busy
:
0
Spare Cell Busy(SW) :
0
Spare Cell Fail
:
0
Spare Cell Fail(SW) :
0
Number of items in output queues:
I=====I=====I=====I=====I=====I=====I=====I
I 1 I 2 I 3 I 4 I 5 I 6 I 7 I
I 0 I 0 I 0 I 0 I 0 I 0 I 0 I
I=====I=====I=====I=====I=====I=====I=====I
I 8 I 9 I 10 I 11 I 12 I ATM I SW I
I 0 I 0 I 0 I 0 I 0 I 0 I 0 I
I=====I=====I=====I=====I=====I=====I=====I
abtthgde.book Page 11 Tuesday, June 23, 1998 10:29 AM
Display Timeout Delays 10-11
Figure 10-2 Timeout Parameters Display
Display Timeout
Delays
Display the software and hardware timeout delays.
Table 10-10 Task Actions
Menu
Sequence
[1] system
[3] update
[8] timeout
[2] display
Enter
Result
None
The software and hardware timeout
delays are displayed.
Example
Enter: [1] [3] [8] [2]
The following is a sample timeout delays report:
----------------------------------------------------------Hardware Timeout delay: 30.
Software Timeout delay: 30.
-----------------------------------------------------------
Update Hardware
Timeout Delay
Enter the new hardware timeout delay (in seconds) or 0 to disable the
hardware timeout mechanism.
Table 10-11 Task Actions
Menu
Sequence
[1] system
[3] update
[8] timeout
[3] hardware
Enter
Result
Time-delay
Q
Time-delay - Hardware
time-delay parameter is updated
Q
0: Hardware timeout mechanism
is disabled
or 0
Example
Enter: [1] [3] [8] [3] 10
The hardware time-delay parameter is updated to 10 seconds; the
following message is displayed:
abtthgde.book Page 12 Tuesday, June 23, 1998 10:29 AM
10-12
CHAPTER 10: MANAGING SYSTEM FUNCTIONS
Hardware Timeout delay has been set.
Update Software
Timeout Delay
Enter the new software timeout delay (in seconds) or 0 to disable the
software timeout mechanism.
Table 10-12 Task Actions
Menu
Sequence
[1] system
[3] update
[8] timeout
[4] software
Enter
Result
Time-delay
Q
Time-delay - Software
time-delay parameter is updated
Q
0: Software timeout mechanism
is disabled
or 0
Example
Enter: [1] [3] [8] [4] 10
The software time-delay parameter is updated to 10 seconds; the
following message is displayed:
Software Timeout delay has been set.
Reset Flash Memory
Resets the flash memory with the default factory settings for the 7600
Card, resets and reboots the device.
Table 10-13 Task Actions
Menu
Sequence
[1] system
[5] flash
Enter
Result
None
The flash memory is reset with the
default factory settings and the
device is reset and rebooted.
Example
Enter: [1] [5]
The flash memory is reset with the default factory settings and the device
is reset and rebooted
abtthgde.book Page 13 Tuesday, June 23, 1998 10:29 AM
Update Read-access Password 10-13
Update Read-access
Password
Update the read-access password. Type the new password a second time
to confirm your entry.
Table 10-14 Task Actions
Menu
Sequence
[1] system
[6] password
[1] read
Enter
Result
1 password
The read-access password is
updated.
2 confirmation
Example
Enter: [1] [6] [1]
The following dialog is displayed. Note that the passwords themselves are
not displayed.
Enter the new read password: myreadpassw
Enter the new read password again: myreadpassw
The password has been changed
The read-access password is updated.
Update
Write-access
Password
Update the write-access password. Type the new password a second time
to confirm your entry.
Table 10-15 Task Actions
Menu
Sequence
[1] system
[6] password
[2] write
Enter
Result
1 password
The write-access password is
updated.
2 confirmation
Example
Enter: [1] [6] [2]
The following dialog is displayed. Note that the passwords themselves are
not displayed.
abtthgde.book Page 14 Tuesday, June 23, 1998 10:29 AM
10-14
CHAPTER 10: MANAGING SYSTEM FUNCTIONS
Enter the new write password: mywritepassw
Enter the new write password again: mywritepassw
The password has been changed
The write-access password is updated.
Update
Admin-access
Password
Update the admin-access password. Type the new password a second
time to confirm your entry. You will be prompted for the existing
password before you enter the new password.
Table 10-16 Task Actions
Menu
Sequence
[1] system
[6] password
[3] admin
Enter
Result
1 password
The admin-access password
is updated.
2 confirmation
Example
Enter: [1] [6] [3]
The following dialog is displayed. Note that the passwords themselves are
not displayed.
Enter the old admin password: myadminpassw
Enter the new admin password: myadminpassw
Enter the new admin password again: myadminpassw
The password has been changed
The admin-access password is updated.
Enable/Disable
Event Messages
Enable or disable Administration Console event messages. Each
application of the command toggles enable/disable. If enabled, event
messages pop-up on the Administration Console screen when events
occur, for example, “link up” when a cable is connected to a port.
abtthgde.book Page 15 Tuesday, June 23, 1998 10:29 AM
Reset and Reboot 10-15
Table 10-17 Task Actions
Menu
Sequence
[1] system
[7] event
Enter
Result
None
Event messages are
enabled/disabled.
Example
When Administration Console event messages are disabled Enter: [1]
[7]
Administration Console event messages are enabled.
Reset and Reboot
Reset system hardware and reboot the device for the new system settings
to take effect.
Table 10-18 Task Actions
Menu
Sequence
[1] system
[8] reset
Enter
Result
None
System hardware is reset and device
is rebooted.
Example
Enter: [1] [8]
This will reset and reboot the device? Are you sure (Y/N)?
System hardware is reset and device is rebooted.
abtthgde.book Page 17 Tuesday, June 23, 1998 10:29 AM
III
7600 Card Capabilities
Chapter 11
Ethernet LANs and Bridges in the 7600 Card
Chapter 12
ATM, LAN Emulation, and Virtual LANs
Chapter 13
Traffic Management in the ATM Network
Chapter 14
Device Management
Chapter 15
System Modes, Attributes, and Tuning
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
11
ETHERNET LANS AND BRIDGES IN
THE 7600 CARD
This chapter provides basic concepts and information about the following
topics and how they are implemented in the 7600 Card.
Overview of
Ethernet
Q
Overview of Ethernet
Q
Fast Ethernet
Q
Transparent Bridges
Q
Spanning Tree Protocol
Q
Bridged-LAN Environments and vLANs
An Ethernet is a CSMA/CD (Carrier Sense, Multiple Access with Collision
Detection) LAN. Carrier Sense means that a device on an Ethernet senses
the traffic and transmits only when the medium is idle. Multiple Access
means that many devices share the same medium and have equal access
rights to transmit. Collision Detection means that devices monitor the
medium even while they are transmitting and so can detect a collision,
that is, another station transmitting while they are transmitting.
The speed of transmission on an Ethernet LAN is normally 10 Mbps.
Stations on an Ethernet LAN can include computers, workstations or
terminals. Ethernet LANs use a common bus that consists of a coax,
twisted pair or fiber-optic cable that runs between the stations. The
connection point of each station to the cable is called a node. Two or
more LANs can be connected together by a bridge to form an efficient
bridged-LAN environment. In this context, an Ethernet LAN is also called
an Ethernet segment.
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
11-2
CHAPTER 11: ETHERNET LANS AND BRIDGES IN THE 7600 CARD
Figure 11-1 Ethernet LAN (Ethernet Segment)
Fast Ethernet
Fast Ethernet is a new LAN technology that uses the same CSMA/CD
transmission method as the basic 10 Mbps Ethernet LAN described in the
previous section but all timing parameters are increased by a factor of 10.
In addition, it supports a full duplex mode as described below.
Fast Ethernet uses the same types of hub-and-spoke topologies used by
10BASE-T Ethernet, the dominant form of 10 Mpbs networking in use
today. It uses the same types of wiring, the same software protocols and
is supported by a large number of the same vendors. In short, 100BASE-T
provides a non-disruptive, smooth evolution from current 10BASE-T
Ethernet to high-speed 100 Mbps performance.
The packet format, packet length, error control and management
information in 100BASE-T are practically identical to those in Ethernet. To
higher layers of software, 100BASE-T appears indistinguishable from
regular Ethernet. All the popular protocols like TCP/IP, as well as
applications, work on Fast Ethernet, only faster.
Network managers benefit substantially from the unchanged protocols;
they can understand and deploy Fast Ethernet with minimal additional
training.
Capabilities
The Fast Ethernet ports of the 7600 Card have the following capabilities:
Q
Auto-negotiation
Q
Full/half duplex transmission mode
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Fast Ethernet
Q
11-3
10/100 Mbps transmission speed
These capabilities differ between the Tx and Fx port types. They are
presented in the following table and discussed in the paragraphs below.
Table 11-1 Fast Ethernet Port Capabilities
Port type
Capability
Tx Port
Fx Port
Auto-negotiation
yes
no
Full/half duplex
yes
yes
yes
no (100 Mbps
only)
10/100 Mbps
Auto-negotiation
The 7600 Card has the capability of negotiating with the device with
which it is to communicate prior to data transfer in order to determine its
mode and speed capabilities (auto-negotiation). The 7600 Card then
automatically adjusts its data transmission mode and speed to match that
of the communicating device as detailed in the next two sections.
Auto-negotiation is set for each port separately and may be set
individually for either transmission mode or speed. If auto-negotiation is
not specified, the parameter must be set manually. The auto-negotiation
capability is available for Tx ports (copper) only.
Full or Half Duplex Mode
Fast Ethernet as implemented in the 7600 Card can communicate in
either full or half duplex mode, for both Tx and Fx port types. The
duplex auto-negotiation capability is available for Tx ports only. The Fx
ports must be set manually to either full or half duplex. When duplex
auto-negotiation is selected, the mode in which the 7600 Card chooses to
operate is determined by the communication modes available in the
device with which it is communicating. If the device with which it is
communicating also has a full-duplex mode (such as another 7600 Card),
then it communicates in full-duplex, otherwise it communicates in
half-duplex.
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
11-4
CHAPTER 11: ETHERNET LANS AND BRIDGES IN THE 7600 CARD
10 or 100 Mbps Speed
The 7600 Card can communicate with either a 10 Mbps or in a 100
Mbps communication rate. This capability is available for the Tx port
type only. The Fx ports communicate in 100 Mbps only. The Tx ports
also have a speed auto-negotiation capability. When speed
auto-negotiation is selected, the speed in which the 7600 Card chooses to
operate is determined by the communication speed available in the
device with which it is communicating. If the device with which it
communicating also has a 100 Mbps speed (such as another 7600 Card)
then it communicates in 100 Mbps, otherwise it communicates in 10
Mbps. The Fast Ethernet uses a lower bit-time (the time duration of each
bit transmitted), but leaves the remainder of the Ethernet CSMA/CD
unchanged.
Cabling
Fast Ethernet supports structured wiring composed of category 3, 4, and
5 unshielded twisted pair (UTP), 150 ohm shielded twisted pair (STP) and
fiber. These media specifications cover almost all cable types currently in
use. Equally important, all supported media types can be mixed together
and connected through a repeater or switch, just as with the earlier
Ethernet media types.
To support these various wiring types, Fast Ethernet provides three
transceiver types. A transceiver is that portion of an adapter containing
the analog circuitry necessary to transmit and receive data on a physical
cable. In Table 11-2, each transceiver type supports a different set of
cable applications. It lists two twisted-pair-type transceivers and one fiber
transceiver. These three Fast Ethernet transceiver technologies are
complementary. The 7600 Card module uses the STP and fiber cable
types.
Table 11-2 Cable Support by Transceiver Type
Transceiver type
Cable type
Number of
pairs (fibers)
Notes
100BASE-T4
Category 3 UTP
Category 4 UTP
Category 5 UTP
4
4
5
Workhorse design
for category 3 cable,
100-m link span
100BASE-TX
Category 5 UTP
150 Ω STP
2
2
Only needs two
pairs, 100-m link
span
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Fast Ethernet Ports
11-5
Table 11-2 Cable Support by Transceiver Type
Fast Ethernet Ports
Transceiver type
Cable type
100BASE-FX
62.5/125 µm
multi-mode
fiber
Number of
pairs (fibers)
2
Notes
Same optics as
FDDI, 2-km link
span
Ethernet LANs (Ethernet segments) are physically connected to the 7600
Card through one of its 16 Fast Ethernet ports. Each port has a unique
address and port number. Figure 11-2 below shows Ethernet LANs
connected to the 7600 Card Ethernet ports.
Figure 11-2 Attaching Ethernet LANs to Ethernet ports on the 7600 Card
Disabling Ports
Individual Ethernet ports can be enabled or disabled by management and
the corresponding administrative status can be displayed. When a port is
disabled, data is not received or transmitted through the port.
Monitoring Ports
Each port is continuously monitored and the current operational status of
the port (operating or not operating) can be displayed. Statistics on traffic
through the port are compiled and can be displayed at any time. These
include octets and frames (unicast, multicast, and broadcast) received and
transmitted on the port, as well as discarded frames with the reason for
discarding.
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
11-6
CHAPTER 11: ETHERNET LANS AND BRIDGES IN THE 7600 CARD
Transparent Bridges
The transparent bridge is a device that connects to two or more LANs and
provides a selective data packet transfer capability between them which
allows them to work in a bridged-LAN environment. The bridged-LAN
can support more stations and a greater amount of traffic than can a
simple LAN and, at the same time, it eliminates the cable length
restriction between stations.
Bridge ports
A LAN is attached to a bridge through a bridge port which handles traffic
between the LAN and the bridge. Each bridge port has a unique address.
The bridge ports are numbered internally by the bridge. In the 7600 Card,
bridge ports are numbered differently from the Ethernet ports to which
the Ethernet LANs are physically attached. LANs are assigned to bridges
by associating physical port numbers to bridge port numbers when
setting up the device. Figure 11-4 below shows LANs connected to a
bridge to form a bridged-LAN environment.
Figure 11-3 Forming a bridged-LAN environment
Store-and-Forward
The basic idea of the transparent bridge, as specified in the IEEE 802.1d
bridging standard, is that it listens to every packet transmitted by the
LANs to which it is attached, storing each received packet until it can be
transmitted on the LANs other than the one on which it was received.
Since the entire packet is stored in the bridge and retransmitted only
when the receiving LANs are idle, the cable length restriction needed to
avoid collisions in a single LAN can be exceeded between stations in the
bridged LAN. In addition, the total number of stations in the bridged LAN
can exceed the permissible number in a single LAN because each LAN is
treated separately by the bridge.
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Transparent Bridges
11-7
Forwarding Database
The effective bandwidth of the bridged LAN can be increased by means
of the Forwarding Database (FDB), a memory cache in the bridge which
contains a table of station addresses and associated bridge port numbers.
The FDB provides the bridge port number of a received packet’s
destination station, allowing the bridge to transmit the packet directly to
the correct\ LAN. The FDB is populated in three ways: by learning, by
manual operator entry and by predefined data.
Learning Station
Addresses
The method of learning station addresses, specified in the IEEE 802.1d
standard, is based on the presence of the transmitting station’s (source)
address in the transmitted packet. This makes it possible for the bridge to
associate the source address with the bridge port on which the packet
was received; the bridge now knows to which port the source station is
connected. This information is stored in the FDB and remains there as
long as the transmitting station is active. Because the learned addresses
are not permanently written in the FDB, they are referred to as dynamic
addresses.
Learning while
forwarding
The learning process is executed by the bridge at the same time that
frame forwarding is occurring. The strategy goes as follows:
1 The bridge receives every packet transmitted by its attached LANs.
2 For each packet received, the bridge stores the address in the packet’s
source address field in the FDB together with the bridge port upon which
the packet was received.
3 For each packet received, the bridge looks through its FDB for the
packet’s destination address.
a If the address is not found in the FDB, the bridge forwards the packet
to all LANs except the one from which it was received (flooding).
b If the address is found in the FDB, the bridge forwards the packet only
to the port specified in the table. If the specified port is the one from
which the packet was received, the packet is dropped (filtered).
4 The bridge keeps track of each entry in the FDB and deletes it after a
period of time (the aging time) in which no traffic is received with that
address as the source address. This prevents overflowing of the FDB and
also facilitates moving a station from one LAN to another. The bridge
simply relearns its location. Aging time is one of the bridge parameters
and can be specified by management.
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
11-8
CHAPTER 11: ETHERNET LANS AND BRIDGES IN THE 7600 CARD
Static Addresses
Defining
permanency of
static addresses
The network manager may want to restrict a particular station to
communicate only through specific input and output bridge ports in
order to keep its traffic confined to certain portions of the network
topology. Or, he may want to maintain a station that transmits so
infrequently that it would be aged-out by the aging mechanism. For
these cases the learning method is not suitable. Instead, the FDB provides
for address entries called static addresses. These are entered or removed
manually by the operator (and are therefore also called Management
addresses) or they can be supplied with the device. The Read-only address
is a special type of static address which is supplied with the device for
internal use and cannot be altered. An example of a Read-only address is
the address of a bridge port, called “Self”.
In the 7600 Card, static addresses with various degrees of permanency
can be defined as follows:
Q
Permanent - Entries that remain in the FDB when the device is reset
Q
Delete-on-Reset - Entries that are deleted when the device is reset
Q
Delete-on-Timeout - Static entry that is deleted after the aging time
Allowed ports for
static addresses
Input and output bridge ports assigned (allowed) to a static address are
entered or removed by the operator or are predefined. Static addresses
can be addresses of individual destination stations but they are more
frequently multicast addresses - addresses which include a group of
destination stations. A packet with a multicast address normally needs to
be transmitted on more than one bridge port in order to reach all the
destination stations. Consequently, multiple output bridge ports are often
allowed to a single static address. For data display, multiple allowed
output ports are coded into a single binary number. Normally, one input
(or receiving) port is allowed to a static address, but it is also possible to
designate all ports as allowed receiving ports.
Blocking ports for
static addresses
Instead of specifying the allowed input and output bridge ports for a
static address, it is sometimes more convenient to specify those input and
output bridge ports which are not allowed for that address (blocked
ports). Then all ports other than the blocked ports can receive and
transmit for that address.
Spanning Tree
Protocol
When designing a bridged-LAN environment is it desirable to build
redundant bridge links between LANs: in case one link fails, another can
serve as a backup. However, when a LAN is attached to two or more
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
Spanning Tree Protocol
11-9
transparent bridges the bridged LAN can contain paths on which packets
may loop and multiply, lowering its effective overall bandwidth.
Figure 11-4 Packet looping through redundant bridges
To solve this problem, the IEEE 802.1d Bridging Standard describes the
Spanning Tree Protocol (STP), an algorithm which seeks to establish a
unique path between each pair of LANs in the bridged network by
selectively blocking redundant bridge ports. The resulting loop-free tree
spans the network: each LAN can access any other LAN. The STP
continuously monitors the tree and, in the event of a failure, acts to
establish a new spanning tree by reactivating blocked ports.
The STP is executed collectively by the bridges themselves by means of
special messages called Configuration Bridge Protocol Data Units
(CBPDUs) continuously sent between them. Using these messages, the
bridges inform the other bridges of their unique bridge-ID, and they
calculate the shortest (lowest cost) path from themselves to other
locally-connected bridges. Using this information, the STP determines the
following:
Root Bridge
Root Port
The root-bridge is selected among all bridges on the LANs as the one with
the lowest bridge ID. The network manager can influence the algorithm’s
choice of root bridge through the management parameter
bridge-priority. The bridge-priority is appended as the most significant
part of a bridge ID; the lower its value, the more likely the bridge is to
become the root.
Once the root bridge has been determined, each bridge selects the port
with the shortest path from it to the root bridge to be the root-port.
abtthgde.book Page 10 Tuesday, June 23, 1998 10:29 AM
11-10
CHAPTER 11: ETHERNET LANS AND BRIDGES IN THE 7600 CARD
Designated Bridge
on a LAN
Among all bridges on a LAN, the bridge with the shortest path to the root
bridge (through its root port) is selected as the designated-bridge on that
LAN.
Spanning Tree port
selection
Each bridge selects its root port and any of its ports (LANs) on which it is
the designated bridge to be in the spanning tree. All other ports are
blocked to data traffic (but not to CBPDUs). Thus, traffic on a LAN flows
only through its designated bridge.
Re-configuring the
Spanning Tree
When a change occurs in the network, such as a new bridge or link or a
device failure, the STP acts to establish a new Spanning Tree
configuration. Until the new Spanning Tree configuration stabilizes, it is
necessary to restrict data packet transmissions in order to avoid
temporary loops. For this purpose the 801.2 standard calls for two
intermediate bridge port states: the listening state followed by the
learning state. In the listening state is a wait state in which a port neither
learns station addresses nor forwards data packets. In the learning state a
port learns station addresses but still does not forward data packets. The
management parameter forward-delay controls the amount of time that
a bridge port remains in the listening or the learning state.
Port States
Disabling the STP
Summing up, a bridge port can be in one of the following port states:
Q
Listening - When the Spanning Tree begins re-configuring after a
network change, all ports are placed in the listening state. Data
packets received on a port are discarded. After the forward-delay
time, the bridge port enters the learning state, unless set to the
blocking state by the STP.
Q
Learning - Data packets are received for the purpose of learning
station addresses only. After the forward-delay time, the bridge port
enters the forwarding state, unless set to the blocking state by the STP.
Q
Blocking - The bridge continues to send and receive CBPDUs on that
port but does not receive data packets.
Q
Forwarding - The bridge performs standard bridging functions.
The STP can be disabled and enabled by management either for the
entire bridge or for specific ports. When disabled, the port or bridge does
not participate in the Spanning Tree algorithm but continues to receive
and transmit data packets.
abtthgde.book Page 11 Tuesday, June 23, 1998 10:29 AM
Bridged-LAN Environments in the 7600 Card 11-11
Management Bridge
Parameters
The following bridge parameters can be set by management. The
parameters listed in Table 11-3, are port-independent while the
parameters in Table 11-4 are set for individual bridge ports.
Table 11-3 Port-independent Bridge Parameters
Parameter
Description
Bridge-priority
A 2-octet value that allows the network manager to influence the choice of root bridge and
the designated bridge. It is appended as the most significant portion of a bridge ID. It can
also detect the case where two or more ports on the same bridge are attached to the same
LAN, i.e. are in direct communication through a path of bridged LAN components, none of
which operate the STP.
Bridge-hello-time
The time that elapses between generation of CBPDUs by a bridge that assumes itself to be
the root bridge. It is also the time interval between transmissions of Topology Change
Notification BPDUs to the root bridge when the bridge is trying to communicate a topology
change to the designated bridge on the LAN to which its Root Port is attached. The
recommended time is 2 secs.
Bridge-max-age
The message age value at which a stored CBPDU is discarded. The value recommended in
802.1d is 20 secs.
Bridge-forward-delay
A parameter that prevents a bridge from forwarding data packets until the changes in the
spanning tree have been completed throughout the network. It is the time spent in the
Listening State and the Learning State. It is also used for the aging time of dynamic entries in
the Filtering Database while the Topology Change flag is set in protocol messages received
from the root. The value recommended in 802.1d is 15 secs.
Bridge-aging-time
Dynamic station addresses are discarded from the FDB when no data is received from the
station for bridge-aging-time. Static addresses with a delete-on-timeout status are also
discarded after Bridge-aging-time. Recommended default: 5 min.
Table 11-4 Port-dependent bridge parameters
Parameter
Description
Bridge-port-priority
A 1-octet value that allows the network manager to influence the choice of port when a
bridge has two ports connected in a loop. It is appended as the most significant portion of
the port ID.
Bridge-path-cost
The cost to be added to the root path cost field to determine the cost of the path to the root
through this port. The larger the value for the path-cost, the less through traffic the LAN
reached through the port will carry.
Bridged-LAN
Environments in the
7600 Card
The 7600 Card provides a flexible, user-defined bridging capability
designed to support local bridged-LAN environments of different sizes.
abtthgde.book Page 12 Tuesday, June 23, 1998 10:29 AM
11-12
CHAPTER 11: ETHERNET LANS AND BRIDGES IN THE 7600 CARD
Local Bridged-LAN
Environment
For the purpose of forming bridged-LAN environments, the 7600 Card
provides up to 16 internal bridges that can be configured by
management. On setup, one bridge is allocated to each bridged-LAN
environment that is to operate in the 7600 Card. Each local LAN segment
is then attached to a port of the bridge corresponding to the
bridged-LAN environment in which it is to operate. bridges are
configured by management in the Fast Setup (see Chapter 3) or in the
Virtual LAN Configuration menu see (Chapter 5). For management
purposes the bridges are numbered from 0 to 3 in each one of the four
contexts. Figure 11-5 shows two local bridged-LAN environments,
Engineering and Finance, connected to bridges on a 7600 Card.
Figure 11-5 Bridged-LAN environments connected to a 7600 Card
Connection to the
ATM Network
In Chapter 12, the possibility of connecting bridges in the 7600 to the
ATM network is discussed. For each bridge, an ATM connection can be
configured through which the bridge is attached to an Emulated LAN (see
“Bridges in the 7600 Card” on page 12-10).
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
12
ATM, LAN EMULATION, AND
VIRTUAL LANS
This chapter provides basic concepts and information about:
ATM Overview
Q
ATM Overview
Q
Virtual Channels
Q
Interim Local Management Interface (ILMI)
Q
LAN Emulation Overview
Q
Emulated LAN Components
Q
Emulated LAN Connections
Q
Bridges in the 7600 Card
Q
Data Transmission over an Emulated LAN
Q
LEC Parameters
Q
Virtual LANs Overview
Q
Virtual LANs in the 7600 Card
The Asynchronous Transfer Mode (ATM) is a telecommunications method
for carriage of a complete range of user traffic, including voice, video and
data. Defined by CCITT and ANSI standards, it facilitates multi-media
networking between high-speed devices at multi-megabit speeds.
Using this connection-oriented, switched networking technology, virtual
channels may be set up to support multiple applications through the
same physical connection. The switching technology enables dedicated
bandwidth for each application, overcoming the restrictions that exist in a
shared-media networking technology, like Ethernet, Token Ring and FDDI.
ATM allows different types of physical layer technology to share the same
lower layer – the ATM layer.
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
12-2
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
ATM Basics
Cell Switching
ATM uses short, fixed length packets called cells. The first five bytes of
each cell, the header, contain the information necessary to deliver the cell
to its destination.
Fixed-length cells offer the following advantages:
Network interfaces
Layered architecture
Q
Network and switching queueing delays are more predictable with
fixed data cells than for variable-length packets.
Q
Cell switching is less complex and more reliable. ATM hardware can be
implemented more efficiently because control structures, buffers, and
buffer management schemes can be designed to known size criteria.
Q
Cell-relay switches can process cells in parallel, achieving speeds that
far exceed the limitations of packet switch architectures.
Q
Having all data in the same cell format speeds transmission
dramatically by eliminating the need for protocol recognition and
decoding. A good analogy is containerised shipping where uniform
shape and weight of containers and standardized labelling
considerably ease and quicken processing.
Q
The cell format also allows for multi-protocol transmissions. Since ATM
is protocol transparent, the various protocols can be transferred at the
same time. With ATM, one line can carry phone, fax, video, data and
other information simultaneously. This multiprotocol advantage also
offers scalability, greatly reducing the configuration changes necessary
for adding a new traffic type to your network.
ATM establishes the User Network Interface (UNI) which is typically used
to interconnect an ATM user with an ATM switch that is managed as part
of the same network, as well as the Network to Network Interface (NNI)
which is typically used to interconnect two ATM switches managed as
part of the same network.
ATM is based on a layered architecture. In the protocol stack, the ATM
layer sits directly above the physical layer. Many physical layers can be
specified, including several for 100 to 155 Mbps. The ATM adaptation
layer (AAL) sits above the ATM layer. LAN Emulation (LE) sits above the
AAL5 in the protocol hierarchy.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Virtual Channels
Virtual Channels
12-3
ATM is a connection-oriented transport service, much like a telephone. As
opposed to Ethernet, where data is sent out on a common bus, ATM
requires that a virtual channel connecting the source station to the
destination station be established before data transmission can begin. A
virtual channel does not necessarily correspond to a single physical line
and, in fact, may pass through many different network devices and cables
before reaching its destination.
Virtual Channel
Connection
ATM seeks to establish an optimum path for a cell to travel through the
ATM network from source to destination. This path is called a virtual
channel connection (VCC). Its specification is coded into a VCC identifier
which is then placed in each cell header. Using this information,
high-speed buffer management and control schemes route ATM cells
between ports along the path. To access the ATM network, a transmitting
station requests a VCC between itself and a destination station, using the
signalling protocol to the ATM switch. At connection time, a VCC is
established between the stations and a VCC identifier is assigned to the
connection.
Virtual Path
Connection
In addition to the VCC, another type of virtual connection called a virtual
path connection (VPC) can exist on the same physical link. The VPC is a
higher level “container” connection which includes one or more VCCs.
A VCC is uniquely identified by the combination of Virtual Path Identifier
(VPI) and Virtual Channel Identifier (VCI) values and a VPC is uniquely
identified by the VPI value.
VPCs and VCCs can be set up either dynamically via signalling, in which
case it is called a switched virtual circuit (SVC), or permanently by
management where it is called a permanent virtual circuit (PVC).
Permanent Virtual
Channels
A PVC connection is set up manually by management (for example,
SNMP). A PVC connection, once established, is not automatically released
and is not dynamically checked and reinitiated.
The characteristics of the PVC connection include:
Q
Connections initiated by network administrator
Q
Connections established and released manually
Q
Long-term duration connections
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
12-4
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
Q
Switched Virtual
Channels
Point-to-point and point-to-multipoint connections
SVC connections are defined dynamically as they are needed and released
when not needed, using signalling as per ATM Forum UNI standards. By
using SVC, ATM devices can exchange connection characteristics when
establishing connections. These connections remain active for as long as
the application demands. Both point-to-point and point-to-multipoint
connections can be established. SVC eliminates the need for an external
management station for setting up virtual channels.
The characteristics of the SVC connection include:
Interim Local
Management
Interface (ILMI)
Q
Connections initiated by the user/application
Q
Connections established and released dynamically
Q
Connections established via the signalling protocol
Q
Varied connection duration
The Interim Local Management Interface (ILMI) communication protocol
is an open management protocol that supports the bi-directional
exchange of management information between all end-stations and the
switches to which they are connected.
The ILMI functions for a UNI provide status, configuration, statistics, and
control information about link and physical layer parameters at the UNI.
In addition, it provides for address registration across the UNI. ILMI
communications use SNMP directly over the AAL5.
For any ATM device, there is a connecting device associated with each
UNI that supports the ILMI functions for that UNI.
ILMI Management
Information Base
(MIB)
Managed objects are accessed via a virtual information store, termed the
Management Information Base or MIB. Each object defined in the MIB
has a name, a syntax, and an encoding. The UNI ILMI attributes are
organized in a standard MIB structure; there is one UNI ILMI MIB structure
instance for each side of the UNI.
The IILMI MIB provides the management application with the capability to
control and monitor the ATM link and physical layer. The following types
of management information are available in the ILMI ATM UNI MIB:
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
LAN Emulation Overview
ATM Address
Registration
LAN Emulation
Overview
Emulated LAN
Components
Q
Physical Layer
Q
ATM Layer
Q
ATM Layer Statistics
Q
Virtual Path Connections (VPC)
Q
Virtual Channel Connections (VCC)
Q
Address Registration Information
Q
Service Registry Table
12-5
In order to establish an ATM connection at the UNI, both the user and the
network must know the ATM addresses which are in effect at that UNI.
These ATM addresses can then be used in signaling messages for
establishing connections with a specific ATM end system. The address
registration procedure provides the means for the dynamic exchange of
addressing information between the user and the network at the UNI, at
initialization and at other times as required.
LAN Emulation (LE) is a method of connecting LAN users over an ATM
network which enables them to communicate with each other as if they
were operating over traditional LANs. LE can be configured in a ATM
network in several ways:
Q
To connect legacy end stations directly to other legacy systems, as well
as to servers, routers, switches and other networking devices attached
to the ATM network.
Q
To connect bridged-LAN environments to each other over ATM. In this
case the Emulated LAN acts as a bridge on the ATM network.
Q
To connect ATM end stations to each other, enabling communication
between them.
LAN Emulation is implemented as a set of connection services collectively
called an emulated LAN (ELAN). Each ELAN is a composed of a set of LAN
Emulation Clients (LEC) and a single LAN Emulation Service. The latter
consists of an LE Configuration Server (LECS), an LE Server (LES), and a
Broadcast and Unknown Server (BUS). Each LE Client is incorporated in
an ATM end station, such as a SuperStack II Switch 2700 or 7600 Card,
and represents a set of LAN users, identified by their MAC addresses. The
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
12-6
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
LE Service normally resides on a central ATM switch, such as the CELLplex
7000, but may reside on an ATM end station instead.
An ELAN is assigned a name (ELAN name) which is communicated to
each LEC as the LEC joins the ELAN.
More than one emulated LAN can operate on the same ATM network.
However, each of the emulated LANs is independent of the others and
users cannot communicate directly across emulated LAN boundaries.
LAN Emulation Client
The LEC is the LE connection service located in an ATM edge device which
represents the device’s LAN users to the ATM network. A LEC has a
unique LEC ID as well as an ATM address by which it is known in the
emulated LAN. It handles the forwarding of its LAN users’ data frames
over the ATM network to their destination, a task which also includes
ascertaining the destination LEC address and setting up the connection
between them.
Also provided is a MAC-level emulated Ethernet service interface to
higher level software which implements the LAN Emulation User to
Network Interface (LUNI).
LAN Emulation Server
Broadcast and
Unknown Server
(BUS)
The LES is the central “directory” service of an emulated LAN to which a
LEC can turn to look up the ATM address of another LEC. The LES
directory contains a table of LAN station MAC addresses together with
the ATM addresses of the LECs that represent them. In order to transmit a
data frame to a particular destination MAC address, the LEC sends the
data frame to the LEC that represents that destination MAC address. If
the LEC does not already know the destination LEC’s address, it can send
the destination MAC address to the LES to look it up (resolve). To
populate the LES directory, the LECs may register the MAC addresses of
LAN stations they represent with the LES.
The BUS is the LE connection service which handles ATM traffic other
than direct transmissions between LECs. It handles the following:
Q
Data sent by a LEC to the broadcast MAC address
Q
All multicast traffic
Q
Initial unicast frames which are sent by a LEC before the data direct
virtual connection to the ATM address has been resolved
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Emulated LAN Connections
Q
12-7
Unknown traffic
All broadcast, multicast and unknown traffic to and from a LEC passes
through a single BUS.
The BUS also handles ATM connections and manages its distribution
group.
LAN Emulation
Configuration Server
(LECS)
Emulated LAN
Connections
The LECS assigns individual LAN Emulation clients to different emulated
LANs. When a LEC initializes, it establishes connection to the LECS. Based
on its own programming, configuration database and information
provided by clients, it assigns any client which requests configuration
information to a particular emulated LAN service by giving the client the
LES’s ATM address. This method supports the ability to assign a client to
an emulated LAN based on either the physical location (ATM address) or
the identity of a LAN destination which it is representing (ELAN name).
Emulated LAN components communicate with each other by means of
VCCs. Control signals and data transmissions are handled by separate
VCCs: Control VCCs and Data VCCs.
Control VCCs
The control VCCs carry control traffic such as LE_ARP requests and
responses. On initialization, control VCCs are established between LEC
and LES (bi-directional control-direct VCC and control-distribute VCC) as
well as a bi-directional configuration VCC between LEC and LECS.
Characteristics of the control VCCs are summarized in the following
table.
Table 12-1 Control VCCs
VCC Name
From/To
Information carried
Initialized by
Duration
Configuration
LEC<==>LECS
LEC requests and receives
configuration information
from LECS, including LES
address
LEC
While needed
Control-direct
LEC<==>LES
LEC sends and receives
controls from LES, including
LE_ARP information
LEC
Membership of
LEC in ELAN
Control-distribute
LES==>LEC
LES distributes control traffic LES
to LECs, including LE_ARP
information
Membership of
LEC in ELAN
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
12-8
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
LEC Control Frame
Statistics Display
The operator can display statistics on the various types of control frames
in and out of the LEC (see “Display LEC Control-frame Statistics” on page
8-14)
Data VCCs
Data VCCs carry data frames between LECs and between a LEC and the
BUS. Unicast data is normally sent from one LEC to another LEC by
data-direct VCCs. Data direct VCCs are set up dynamically in a SVC
environment by a transmitting LEC after ascertaining the ATM LEC
destination address for the packet to be transmitted. Once established, a
data-direct VCC remains in place for transmission of subsequent traffic
between the two LECs. However, a data direct VCC that remains unused
for VCC-Timeout-period is released by the LEC.
A multicast data VCC pair (multicast-send and multicast-forward) are
established between a LEC and the BUS in order to allow the LEC to send
and receive multicast data. In addition, initial unicast data (data whose
LEC destination has not yet been ascertained by the transmitting LEC) is
sent on the multicast-send VCC to the BUS which forwards it to all other
LECs in the same ELAN. Characteristics of the data VCCs are summarized
in the following table:
Table 12-2 Data VCCs
VCC Name
From/To
Information carried
Initialized by
Duration
Data-direct
LEC<==>LEC
Point-to-point Unicast data
between LECs
LEC
Established by
need and released
when unused for
VCC-Timeoutperiod.
Multicast-send
LEC<==>BUS
LEC sends multicast and
initial unicast data to BUS
LEC
Membership of
LEC in ELAN.
Multicast-forward
BUS==>LEC
BUS distributes data traffic to BUS
LECs
Membership of
LEC in ELAN.
Figure 12-1 illustrates the VCCs active among LAN Emulation
Components.
abtthgde.book Page 9 Tuesday, June 23, 1998 10:29 AM
Emulated LAN Connections
12-9
Figure 12-1 VCCs in LAN Emulation Components
LEC Configuration
and Status
Information
The following information about the configuration of the bridge LEC in
the ELAN to which it belongs including connections to LECS, LES and BUS
can be displayed to the operator (see “Display Current LEC
Configuration” on page 8-4).
Table 12-3 LEC Configuration and Status Information
LECS Information
Description
ATM Address
The ATM address of the LECS. This address is obtained from the attached ATM Switch
during initialization of the LEC. It is obtained via ILMI or, alternatively, retrieved from
flash (manually assigned). If the address is not available by these methods, the
well-known address is used to open a configuration VCC. The well-known address is
displayed in this case.
Config VCC
VPI/VCI values of the configuration VCC to the LECS. It is an VCC which is determined
during initialization of the LEC using the above LECS ATM address.
LES Information
Description
ELAN Name
The alphanumeric name of the Emulated LAN (ELAN) to which the LEC belongs. A
default physical name is automatically provided when the LEC joins the ELAN. This
physical name can be replaced with a descriptive name by management.
LEC ID
LAN Emulation Client (LEC) identification assigned by the LES.
abtthgde.book Page 10 Tuesday, June 23, 1998 10:29 AM
12-10
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
Table 12-3 LEC Configuration and Status Information (continued)
ATM Address
ATM address of the LES provided by the LECS during the configuration phase or
manually assigned using the LES address option of the LE configuration menu or in Fast
Setup.
Control-direct VCC
VPI/VCI values of the control-direct VCC originated by the LEC to the LES.
Control-distribute VCC
VPI/VCI values of the control-distribute VCC originated by the LES to the LEC.
BUS Information
Description
ATM Address
ATM address of the BUS provided by the LES during initialization.
Multicast-send VCC
VPI/VCI values of the multicast-send VCC originated by the LEC to the BUS.
Multicast-forward VCC
VPI/VCI values of the multicast-forward VCC originated by the BUS to the LEC.
Bridges in the 7600
Card
In the 7600 Card a LEC is attached to each Ethernet transparent bridge
which is set up in the device. The LEC connects the bridged-LAN
environment attached to the transparent bridge to the ATM network and
forwards LAN data frames over VCCs across the ATM network to the
destination LANs. From the viewpoint of a LAN user, the LEC acts
together with the transparent bridge to which it is attached to form a
combined bridge through which the LAN user can now efficiently reach
both local and remote destination LANs in the ATM network.
The physical connection of the transparent bridge to the ATM network is
through an internal ATM port. The connection to the ATM port is
specified when the bridge is set up. If no ATM connection is specified, the
bridge acts like a standard transparent bridge.
abtthgde.book Page 11 Tuesday, June 23, 1998 10:29 AM
Bridges in the 7600 Card 12-11
Figure 12-2 Bridges in the 7600 Card
The following figure shows data-direct VCCs configured between two
7600 cards:
Figure 12-3 Virtual Circuit Connections
Cell Switching in the
Bridge
In fact, both Ethernet and ATM switching in the bridge are combined in a
single ASIC called ZipChip. Using a technique called cell switching, all
data is converted to standard sized cells. The ZipChip’s local memory is
optimized for storing these data cells. The data in the memory is either
converted to Ethernet frames when transmitted on the Ethernet port or
to ATM/LAN Emulation frames when transmitted on a VCC. The cell data
need never be copied as it is merely converted to the appropriate format
by the ZipChip on its way in and out of memory.
abtthgde.book Page 12 Tuesday, June 23, 1998 10:29 AM
12-12
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
Bridge Forwarding
Database
In order to forward data frames efficiently to both local LAN stations on
the transparent bridge as well as to remote LAN stations represented by
other LECs on the ATM network, a combined Forwarding Database (FDB)
is established and maintained in the bridge. This FDB combines two
tables. The first table is the FDB of the transparent bridge itself: a list of
local LAN station MAC addresses together with the numbers of the
bridge port to which they are attached (see “Forwarding Database” on
page 11-7). The second table, called the LE ARP-cache, contains a list of
remote LAN station MAC addresses together with the ATM addresses of
the remote LECs which represent them. When a data frame is received at
the bridge it searches its FDB for the destination MAC address. If the
address is found to be local, the frame is forwarded to the appropriate
bridge port. If the address is remote, the frame is sent over ATM to the
destination LEC.
The part of the FDB of the bridge corresponding to the transparent bridge
is populated as in a standard bridge (see “Forwarding Database” on page
11-7). The ARP-cache is populated by the following methods:
Address Resolution
Q
Address resolution - querying the LES
Q
Address learning - from received data packets
When the bridge needs to forward a unicast data frame whose
destination MAC address is not found in its FDB it attempts to locate a
LEC that represents the destination MAC address on the ATM network.
To do this, it turns to the LES in a process called address resolution.
As mentioned above, the LES is the central “directory” service for
verifying LEC ATM addresses on an ELAN (see “LAN Emulation Server” on
page 12-6). The LEC submits an LE_ARP (LE Address Resolution Protocol)
Request to the LES. If an LEC ATM address corresponding to the
submitted MAC address is found in the LES table it is transmitted back to
the requesting LEC as an LE_ARP Response. In case the requested address
is not found at the LES, the LES will forward the query to other LECs to
search the non-registered addresses and then return a positive response
back to the requesting LEC. On receipt of an LE_ARP Response the bridge
records the destination LEC ATM address together with the destination
MAC address in its FDB ARP-cache.
abtthgde.book Page 13 Tuesday, June 23, 1998 10:29 AM
Bridges in the 7600 Card 12-13
Data-direct VCC
On receipt of the destination LEC address, the transmitting LEC
establishes a data-direct VCC for direct communication across the ATM
network to the destination LEC if one does not already exist (the 7600
Card actually inserts a pointer to this VCC directly into the FDB so that a
destination MAC address can be immediately associated with the right
VCC).
VCC to BUS
In a similar way, the bridge uses address resolution during initialization to
ascertain the ATM address of the BUS. Once known, the multicast-send
and multicast-forward VCCs are established between LEC and BUS and
any unknown unicast, multicast or broadcast messages are send on it.
Learning Addresses
The bridge learns addresses from data frames received over data-direct
VCCs in the same manner as the transparent bridge learns from data
frames received from LAN stations on local Ethernet segments (see
“Learning Station Addresses” on page 11-7). The bridge extracts the
source MAC address in each received data frame and compares it with
the entries in the FDB ARP-cache. If not found, it is inserted together with
the ATM address of the LEC that sent it (or, equivalently, the pointer to
the VCC on which it was received). Then, the next time a data frame
needs to be sent to that MAC address, the bridge picks up its VCC from
the FDB ARP-cache.
LES Address
Registration in the
7600 Card
To populate the LES directory, LECs are normally required to register the
MAC addresses of LAN stations they represent with the LES. However, the
situation is different for LAN stations which reside on a transparent
bridge, as is the case for LANs attached to the 7600 Card. In this case, the
LANs are considered to be “remote” from the LEC and the LEC is called a
proxy for the bridged LANs. LES address registration does not apply to
proxy LECs. Instead, LE_ARP requests for MAC addresses on bridged
LANs are passed on by the LES to the proxy LEC for address resolution.
The requested MAC address is found in the bridge FDB and returned in
the LE_ARP response.
Unknown address
Note that in the initial phase of operation of the ELAN, a MAC address of
a bridged LAN station which has been requested from its proxy LEC may
not have been learned yet by the bridge so that the LE_ARP request will
be unsuccessful. As a result, a specific destination LEC address will not be
available to the transmitting LEC and, consequently, no data-direct VCC
will be established. A LAN station MAC address for which no destination
LEC address is available yet is called an unknown address.
abtthgde.book Page 14 Tuesday, June 23, 1998 10:29 AM
12-14
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
Aging in the LE_ARP
Cache
As in the transparent bridge FDB, inactive entries in the LE_ARP cache are
removed (aged out). Two LEC parameters are employed for this purpose:
aging-time and forward-delay-time. The parameter used depends on the
way the entry was originally obtained and if the topology-flag is set.
When the topology flag is set “on” it means that the network is
undergoing a change in configuration. The following table shows the
conditions under which the appropriate aging parameter is chosen.
Table 12-4 Selecting Aging Parameters in the LE_ARP Cache
Entry obtained by
Topology flag
Address resolution where address
was registered in LES
Bridge Frame
Forwarding Logic
Aged by
Aging-time
Address resolution where address
was not registered in LES, e.g. proxy
LECs
Q
Set
Forward-delay-time
Q
Clear
Aging-time
Address learned from received data
frames
Q
Set
Forward-delay-time
Q
Clear
Aging-time
,
A bridge processes an Ethernet frame received on a bridge port as
follows:
1 The destination address is looked up in the combined Forwarding
Database.
2 If the destination address is a local station MAC address the frame is
forwarded directly to the bridge port corresponding to the address.
3 If the destination address is found on a remote LEC, the frame is
converted to the standard LAN Emulation format and sent on to the ATM.
4 If the destination address is defined as “self”, this signifies SNMP, CBPDU
frames or any other traffic directed to the bridge software.
5 If the destination address is unknown, the frame is sent to all local bridge
ports. In addition, it is sent to all other members of the ELAN according to
the unknown unicast flooding mode (see “Unknown unicast flooding
mode” on page 12-15).
6 Multicast addresses are handled similarly to unknown addresses; they are
flooded.
7 Broadcast frames are sent to the bridge software as well as to all other
ports on the bridge including the ATM.
abtthgde.book Page 15 Tuesday, June 23, 1998 10:29 AM
Data Transmission over an ELAN 12-15
Data Transmission
over an ELAN
Unicast Frames
When a LEC has established through address resolution that a certain
LAN destination corresponds to a certain LEC ATM address, and a
data-direct VCC exists to that ATM address, then a data frame addressed
to that LAN destination is forwarded via that VCC.
Unknown Unicast
Frames
When a unicast frame to be transmitted by a LEC has an unknown
address, a data-direct VCC is not yet available. In this situation, there are
two possible actions that the LEC can perform, either separately or in
combination:
Q
The unknown unicast frame can be transmitted over the
multicast-send VCC to the BUS. The BUS forwards the frame to all
LECs and their attached bridges then flood the frame to all bridge
ports to ensure that the frame is received at its destination.
Q
Address resolution can be performed continuously on the unknown
address until the address becomes known and a VCC can be set up.
Unknown unicast flooding mode
The 7600 Card allows these two actions to be performed in combination
according to management selection. The unknown unicast flooding mode
allows the user to specify one of the following possibilities for
transmitting unknown unicast frames by a bridge:
Table 12-5 Unknown Unicast Flooding Mode
Mode
Bridge action
No flooding
No unicast frames are sent to the BUS.
Flooding until ARP
Request
Unicast frames are sent to the BUS until the LE_ARP
request is sent.
Flooding until ARP
Response
Unicast frames are sent to the BUS until the LE_ARP
response is received.
The number of unknown frames sent to the BUS in the time period
maximum-unknown-frame-time is limited by the LEC parameter
maximum-unknown-frame-count.
abtthgde.book Page 16 Tuesday, June 23, 1998 10:29 AM
12-16
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
Flush protocol
According to the previous section, a unicast frame can be sent to a
destination LEC over two VCC paths: a data-direct VCC or a
multicast-send VCC via the BUS. Since a frame transmitted over a
data-direct VCC may arrive sooner, switching between the two VCC
paths during transmission can cause the frames to be received
out-of-order at the destination LEC. The flush protocol is provided to
ensure the correct order of delivery of unicast data frames at all times.
The transmitting LEC establishes a dialog with the destination LEC to
make sure that all traffic on the first VCC has been processed (flushed)
before transmitting on the second VCC.
Multicast Frames
LECs may wish to send frames to a multicast MAC address, and/or they
may wish to receive frames addressed to a given MAC address. In order
to send frames to a multicast MAC address, the LEC sends the frames on
the multicast-send VCC to the BUS. The LEC will also be able to receive
flooded unicast frames and broadcast and multicast frames on the
multicast-forward VCC from the BUS.
Control Information
on Data VCs
In addition, the LE implementation of the 7600 Card complies with the
standard and requires that control information be carried in-band on data
VCs (Flush, Ready frames) and be identified by a special frame header
(LECID field). The 7600 Card can extract these frames from the data as
well as generate control frames as required.
LEC Statistics
Statistical information can be displayed about different types of
data-frame traffic through the LEC (see “Display LEC Statistics” on page
8-2). The operator can also display statistics on the various types of
control-frames in and out of the LEC (see “Display LEC Control-frame
Statistics” on page 8-14)
LEC Parameters
The following LEC parameters govern the operation of the LEC; most can
be set by management:
Table 12-6 LEC Operational Parameters
Parameter
Description
Minimum
Default
Maximum
Control-timeout
Time out period used for timing out most
request/response control frame interactions.
10 seconds
120 seconds
300 seconds
abtthgde.book Page 17 Tuesday, June 23, 1998 10:29 AM
Virtual LANs Overview 12-17
Table 12-6 LEC Operational Parameters (continued)
Parameter
Description
VCC-timeout
An LEC should release any Data-direct VCC
None specified 20 minutes
that has not been used to transmit or receive
any data frames for the length of the VCC
timeout period. This parameter is only
meaningful for SVC Data-direct VCCs.
Unlimited
Aging-time
The maximum time that an LEC will maintain 10 seconds
an entry in its LE_ARP cache in the absence of
a verification of that relationship
300 seconds
Unlimited
Forward-delaytime
The maximum time that an LEC will maintain 4 seconds
an entry for a non-local MAC address in its
LE_ARP cache in the absence of a verification
of that relationship, as long as the Topology
Change flag is true.
15 seconds
30 seconds
Expected LE_ARP
Response-time
The maximum time that the LEC expects an
LE_ARP request/response cycle to take. Used
for retries and verifies.
1 second
1 second
30 seconds
Topologychange-flag
Boolean indication that the LEC is using the
Forward delay time instead of Aging time to
age non-local entries in its LE_ARP cache.
N/A
N/A
N/A
Flush-timeout
Time limit to wait to receive a LE_FLUSH
response after the request has been sent,
before taking recovery action.
1 second
4 seconds
4 seconds
Path-switchingdelay
The time since sending a frame to the BUS
after which the LEC may assume that the
frame has been either discarded or delivered
to the recipient. May be used to bypass the
Flush protocol.
1 second
6 seconds
8 seconds
Connectioncompletiontimer
In Connection Establishment this is the time
period in which data or a READY_IND
message is expected from a Calling Party.
1 second
4 seconds
10 seconds
Maximumunknown-framecount
Maximum number of unknown frames sent
to BUS during the time period
Maximum-unknown-frame-time.
1 frame
1 frame
10 frames
Maximumunknown-frametime
Within the period of time defined by the
Maximum-unknown-frame-time, a LEC will
send no more than
Maximum-unknown-frame-count frames to
the BUS for a given unicast LAN destination.
1 second
1 second
60 seconds
Virtual LANs
Overview
Minimum
Default
Maximum
Virtual LANs (vLANs) represent location-independent logical user groups.
LAN Emulation allows you to create enterprise-wide vLANs that closely
correspond to how your network and business actually function. The
abtthgde.book Page 18 Tuesday, June 23, 1998 10:29 AM
12-18
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
ability to define multiple emulated LANs permits the network manager to
create several bridged LAN domains within a single ATM network.
vLANs create secure workgroups, erect firewalls against broadcast storms
and allow networks to be reconfigured - all without changing cabling or
adding equipment. Network administrators can implement additions,
moves, and changes simply by redefining groups in the network
management system and remotely configuring parameters in the end
device or ATM switch.
In addition, vLANs can extend the life of routers in the network. Since
traffic is switched within the vLAN at full rate, routers need only deal with
the traffic between the vLANs, cutting down on the routed traffic load.
Since traffic is switched within vLANs at full rate regardless of protocol,
you can configure the LAN in a variety of ways without inhibiting
performance. This leaves your routers free to route traffic across the
virtual LAN boundaries and into the WAN.
Virtual LANs in the
7600 Card
Connecting Local
Segments to a vLAN
A vLAN brings together logically related, but not necessarily physically
connected, Ethernet segments on the ATM network into a common
high-bandwidth broadcast domain. A vAN is defined simply as an
Emulated LAN together with all segments attached to it and the stations
connected to these segments. Multiple vLANs can operate independently
on a single ATM network; each vLAN corresponds to a distinct ELAN.
A vLAN will usually contain some Ethernet segments physically connected
to the 7600 Card (local segments) as well as remote segments located in
different parts of the ATM network. Logically, the connection of the local
Ethernet segments into a vLAN proceeds in two steps: first, they are
formed into a local bridged-LAN environment by connecting them to a
local bridge (see “Bridged-LAN Environments in the 7600 Card” on page
11-11) and then the local bridged-LAN environment is connected to
remote bridged-LAN environments in the same vLAN by connecting the
bridge to the Emulated LAN.
The 7600 Card bridge setup handles both of these steps. Local Ethernet
segments are attached one-by-one to the appropriate bridge by simple
menu actions. Then an ATM connection is requested, causing the bridge
to be connected into an Emulated LAN. As a result, when the bridge
setup is completed, the local bridged-LAN environment is already part of
abtthgde.book Page 19 Tuesday, June 23, 1998 10:29 AM
Virtual LANs in the 7600 Card 12-19
a Virtual LAN. The LAN stations communicate over the VCCs set up by
the ELAN.
Figure 12-4 shows how two such vLANs, for example Engineering and
Finance, might be connected on the ATM network. Each vLAN has a
separate ELAN (ELAN 1 and ELAN 2) which establish the data-direct VCCs
on which members of the vLAN communicate. Figure 12-5 shows how an
ELAN is embedded in a vLAN.
abtthgde.book Page 20 Tuesday, June 23, 1998 10:29 AM
12-20
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
Figure 12-4 vLAN Connectivity through 7600 Cards
The following figure shows a different way of viewing the relation
between ELAN and vLAN. The ELAN is embedded in the vLAN.
abtthgde.book Page 21 Tuesday, June 23, 1998 10:29 AM
Virtual LANs in the 7600 Card 12-21
Emulated LAN
LES2
BUS2
CELLplex 7000 chassis
LEC2
LEC3
CELLplex 7000 chassis
7600
modules
Marketing
7600
modules
Virtual LAN
Marketing
Figure 12-5 ELAN in a Virtual LAN
Virtual LANs for three
Workgroups
Figure 12-6 shows the physical and virtual view of a network divided into
three vLANs: Marketing, Finance. and Administration. Even though these
workgroups are distributed over different floors, LAN Emulation allows
them to be managed as if the users were in the same physical location.
Each vLAN communicates with its server.
In the physical view of this network, the members of the Marketing and
Finance groups are separated physically, though they are closely related in
terms of the work that they do and how they use the network. The
physical wiring does not reflect these logical relationships.
The virtual view shows how LAN Emulation can be used to create three
virtual workgroups, each of them managed as if its members were linked
locally. The LAN Emulation servers, which may reside in a switch or some
other network device, help find the ATM addresses of desktop devices,
regardless of where they are located.
abtthgde.book Page 22 Tuesday, June 23, 1998 10:29 AM
12-22
CHAPTER 12: ATM, LAN EMULATION, AND VIRTUAL LANS
Figure 12-6 Logical and Physical View of a Network With vLANs
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
13
TRAFFIC MANAGEMENT IN THE
ATM NETWORK
This chapter discusses the Traffic Management (TM) function within the
ATM network and its implementation in the 7600 Card. The following
topics are discussed:
Overview
Service categories
Q
Overview of the concepts and operation of Traffic Management
Q
How Traffic Management is implemented within the 7600 Card
ATM technology is intended to support a wide variety of services and
applications. Each type of application, whether it be voice, video or data,
has its own special data transmission performance requirements. These
requirements are expressed in a set of parameters called Quality of
Service (QoS) which includes such factors as permissible transmission
delay and loss of information. An important task of the ATM network is
to be able to provide the appropriate QoS requirements for each
application it is carrying. Traffic Management is provided on the ATM
network to protect the network and the end-system from congestion in
order to achieve network performance objectives. An additional role is to
promote the efficient use of network resources. TM allows the devices to
transmit over a broader bandwidth for longer periods of time, making the
network more efficient.
The 7600 Card’s ATM data transmission Traffic Management is based on
the Available Bit Rate (ABR) or Unspecified Bit Rate (UBR) “service
categories”. ABR allows a flow control mechanism to be established
which supports data “feedback” to control the source data transmission
rate in response to changing ATM layer congestion. This feedback is
conveyed to the source through specific control cells called Resource
Management Cells, or RM-cells. An end-system that adapts its traffic in
accordance with the feedback will experience a low cell loss ratio and
obtain a fair share of the available bandwidth according to a network
specific allocation policy. No numeric commitment is made about cell
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
13-2
CHAPTER 13: TRAFFIC MANAGEMENT IN THE ATM NETWORK
transfer delay. The ABR service does not require bounding the delay or
the delay variation experienced by a given connection.
The UBR service category is inherently open-loop. UBR is not subject to a
specific traffic contract but may be subject to a local policy in individual
switches and end-systems. The UBR service category is intended for
non-real-time applications, i.e. those not requiring tightly constrained
delay and delay variation.
Flow Control Model
for ABR
ABR flow control occurs between a sending end-system (source), such as
a 7600, and a receiving end-system (destination). Sources and
destinations are connected via bi-directional connections. For a
bi-directional ABR connection, each connection termination point is both
a source and a destination. For the sake of simplicity, only the information
flow from the source to the destination with its associated RM-cell flows
is considered. The forward direction is the direction from the source to
the destination, and the backward direction is the direction from the
destination to the source. Figure 13-1 shows the data flow and the
RM-cell flow over a VCC connection between the two stations.
Corresponding to the forward data flow from the source to the
destination, there is a control loop consisting of two RM-cell flows, one in
the forward direction and one in the backward direction.
Figure 13-1 Example of a source to destination ABR control loop
A source generates forward RM-cells which are turned around by the
destination and sent back to the source as backward RM-cells. These
backward RM-cells carry feedback information provided by the network
elements and/or the destination back to the source. A network element
may:
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Traffic Management Concepts
13-3
Q
Directly insert feedback control information into RM-cells when they
pass in the forward or backward direction
Q
Indirectly inform the source about congestion by setting the EFCI bit in
the data cell header of the cells of the forward information flow. In
this case, the destination will update the backward RM-cells based on
this congestion information.
Q
Generate backward RM-cells.
Traffic
Management
Concepts
This section contains some of the TM concepts in greater detail.
Explicit Forward
Congestion Indication
The Explicit Forward Congestion Indication (EFCI) is a congestion
notification mechanism that is set in the cell header by a network
element in an pre-congested or congested state. A network element in an
impending congested state or a congested state may set an EFCI in the
cell header so that this indication may be examined by the destination
end-system. For example, the end-system may use this indication to
implement a protocol that adaptively lowers the cell rate of the
connection during congestion or impending congestion. A network
element that is not in a congested state or an impending congested state
will not modify the value of this indication. An impending congested
state is the state when a network element is operating around its
engineered capacity level.
Cell Loss Priority
For some service categories the end system may generate traffic flows of
cells with Cell Loss Priority (CLP) marking. A congested network element
may selectively discard cells explicitly identified as belonging to a
non-compliant ATM connection and/or those cells with their CLP bit set.
This is to protect cells without their CLP bit set from being discarded for
as long as possible.
Implicit Rate Control
In implicit rate control (binary mode) the EFCI bit in the cell header is
checked. If there has been congestion on the forward path (recognized at
the destination end station by the EFCI bits of the incoming data cells),
the Congestion Indication (CI) field within the backward RM cell is
marked (set to one). The source end station receives the backward RM
cell and acts upon it. If the CI field is set or if RM cells are not returned,
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
13-4
CHAPTER 13: TRAFFIC MANAGEMENT IN THE ATM NETWORK
the sending rate is reduced. When the source end station receives a
backward RM cell with the CI bit cleared it may increase the sending
rate on that particular VC.
Explicit Rate Control
Explicit rate control enhances the implicit rate control by adding the
explicit rate (ER) field to the RM cell. In this field the source end station
indicates the rate at which it would like to transmit. If an explicit rate
switch exists in the virtual connection (VC) route it may reduce the ER
field in the backward RM-cells in case of congestion. In this case it
indicates explicit rate for the source end station. The source end station,
upon receiving the backward RM-cells, adjusts its sending rate according
to the ER field.
The traffic management standard as defined by the ATM forum supports
VC routes with both explicit and implicit switches. The standard specifies
how to handle lost RM-cells as well as fairness between competing ABR
connections and enhancements for better link utilization.
Traffic and
Congestion Control
Functions
The following describes the available traffic and congestion control
functions:
Q
Network resource management may be carried out by using virtual
paths. Virtual path connections may be used to separate traffic,
thereby preventing statistical multiplexing with other types of traffic.
The CBR and VBR quality of service classes make use of network
resource management.
Q
Connection admission control is defined as the set of actions taken by
the network in order to establish whether a virtual channel or virtual
path connection can be accepted. The CBR and VBR quality of service
classes make use of connection admission control.
Q
Usage parameter control is defined as the set of actions taken by the
network to monitor and control traffic in terms of traffic ordered and
validity of the ATM connection at the user access. The CBR and VBR
quality of service classes make use of usage parameter control.
Q
Selective cell discarding by network elements of the CLP=1 flow while
still meeting network performance objectives on both the CLP=0 and
CLP=1 flows. The VBR quality of service class makes use of selective
cell discarding.
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
Traffic Rates Shaping in the 7600 Card
Traffic Rates
Shaping in the 7600
Card
13-5
Q
Traffic shaping is a mechanism that alters the traffic characteristics of a
stream of cells on a VCC or a VPC to achieve a desired modification of
those traffic characteristics. The VBR quality of service class makes use
of traffic shaping.
Q
EFCI is a congestion notification mechanism that the ATM layer service
user may make use of to improve the utility that can be derived from
the ATM layer. The ABR quality of service class makes use of Explicit
Forward Congestion Indication.
Q
Explicit Rate uses RM-cells to control the traffic rate through the
network. The ABR quality of service class makes use of explicit rate.
The 7600 Card implements Traffic Management that adheres to the
emerging ATM Forum standards. The Traffic Management makes use of
RM-cells for flow control to allow large networks to be created around
ATM technology without having cell loss due to congestion.
The 7600 Card Traffic Management hardware module contains an ASIC
and local memory for traffic management tables. It performs processing
on ATM cells emerging from or received by the ZipChip. This provides
traffic rate shaping, additional statistics and flexibility in ATM network
configuration.
The 7600 Card checks connected devices for Traffic Management
modules and only activates its own TM module if a corresponding one is
found in the connected device.
RM Cell Usage
RM-cells are used by the network to control the rate flow. The RM cell
format is as defined in the TM specification. These cells are sent at regular
intervals from the 7600 Card and make their way through the network.
In the event that there is congestion, the congestion bit of the RM cell is
set by the destination end station. The RM cell is then returned to the
source 7600 Card. In case the RM-cell is not returned to the source 7600
Card or the CI bit is set, the traffic rate is automatically decreased. A
received RM-cell with the CI bit cleared enables the sending 7600 Card to
increase its sending rate.
No RM-cells are sent on point-to-multipoint connection. Multicast rates
are set in advance to avoid flooding the source with backward RM-cells.
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
13-6
CHAPTER 13: TRAFFIC MANAGEMENT IN THE ATM NETWORK
Flow Rate
Adjustment
Traffic Management in the 7600 Card operates with both EFCI based and
Explicit Rate (ER) based flow control methods.
Transmission Rate
Profiles
The data transmission rate is controlled by means of rate tables called
profiles. Depending on the information received in the returning RM cells
the data transmission rate is indexed up or down in the table. Each table
has an upper and lower rate limit according to need. A set of 32 tables is
pre-loaded into the system and is designed to cover all requirements of
the network. The profiles are identified by their numbers. Please see the
manufacturer for the characteristics of each profile.
Dual-Rate Mechanism
A dual-rate mechanism is used which depends on whether a single VC is
in use or multiple VCs are in use. For a single VC the full rate of 155 Mbps
is used; for multiple VCs the maximum rate is set to one-half the full rate.
Static and Dynamic
TM
TM Remote Client
Database
In the 7600 Card there are two types of Traffic Management: static and
dynamic. The static TM is essentially the dual-rate mechanism described
in the previous section. The dynamic TM is the ABR feedback system
described in the previous sections. The dynamic TM can be enabled and
disabled by the LMA commands. When the dynamic TM is disabled, the
static TM continues to operate.
The TM system works independently for each ATM connection. For
certain remote clients (LECs) it is desirable to set up special TM
characteristics which are used when communicating with it. For this
purpose the 7600 Card maintains a database which holds the
characteristics of each such connection including:
Q
Entry index
Q
TM enable/disable status
Q
Connection type
Q
ATM address of the remote LEC
Q
Profile used when communicating with the remote LEC
Q
TM rate
The database contents can be displayed on the Management terminal
and entries can be added and removed.
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
Traffic Management in the Network
Traffic
Management in the
Network
13-7
Figure 13-2 below shows a network scenario, where two 7600 Cards,
denoted by source station and destination station are found with an ATM
cloud between them. The shaded area between the stations represents a
VCC connection over which a data flow and an RM-cell flow takes place
as shown. The traffic management is performed as follows:
1 A forward RM cell is sent at regular intervals on each VC from the source
end station.
2 The EFCI bit is set in data cells by the ATM switch when congestion is
found along the VC path.
3 The destination end station recognizes the EFCI bit and the backward RM
cell congestion indicator bit is set.
4 The backward RM cell is returned to the source end station through the
ATM switch.
5 VC traffic flow is altered based on information in the RM cell.
Figure 13-2 Traffic Management control steps
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
14
DEVICE MANAGEMENT
This chapter explains the applications enabling administrative and
management functions in the 7600 Card.
The following topics are discussed:
User Interfaces and
Protocols
Q
The user interfaces and protocols used
Q
Management types and connection
Q
Management within the 7600 Card
The following applications provide user interfaces to the 7600 Card:
Q
7600 Card administration console - Local Management (LM).
Q
External SNMP-based network management applications, such as
Transcend Manager.
The 7600 Card uses virtual terminal protocols, such as rlogin and Telnet in
addition to the LM to run the system administration console and SNMP to
run the SNMP-based management applications (refer to Figure 14-1).
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
14-2
CHAPTER 14: DEVICE MANAGEMENT
Figure 14-1 User Interfaces and Protocols used to access the 7600 Card
In-Band &
Out-of-Band
Management
Configuration of the 7600 Card can be performed via an Administration
Console or an SNMP-based external network management application
running on a workstation.
There are two ways of managing the 7600 Card:
Q
In-band, using virtual terminal protocols or SNMP network manager
protocol. Each SNMP network manager has its own user interface to
the management facilities.
Q
Out-of-band, by connecting a VT100 terminal (or a PC with terminal
emulation software) to the serial port on the CELLplex 7000 unit in
which the 7600 Card is installed. The VT100 management interface,
which is a menu-driven user interface built into the 7600 Card, is
used. This management interface provides many of the same features
as SNMP management.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
7600 Card Management
14-3
If there is a dedicated network for management data, then the network is
being managed out-of-band. The advantage of using out-of-band
management as opposed to in-band management is that if the data
network is faulty, the problem can still be diagnosed because the
management requests are sent over a dedicated network. Out-of-band
management is, however, a less convenient and more expensive way to
access the 7600 Card.
7600 Card
Management
Local Management
(LM)
The following protocols are used by the 7600 Card to deliver
management and administration data to and from the 7600 Card: Local
Management (LM), Simple Network Management Protocol (SNMP) and
Virtual terminal protocols.
The Local Management (LM) is a character-oriented, menu-driven user
interface for performing system-level administration. The 7600 Card’s
Local Management is performed through the serial connection in the
host CELLplex 7000 unit.
The management of all 7600 Cards is supported by the Local
Management, regardless of virtual LAN membership.
The Local Management supports the following functions:
Q
Bridge information and configuration
Q
ATM information and configuration
Q
Ethernet information and configuration
Q
IP configuration
Q
System configuration
Q
Virtual LAN and LAN Emulation configuration
Q
Viewing the statistics and status information
Q
Viewing the event log
Figure 14-2 shows the connections required to manage the 7600 Card.
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
14-4
CHAPTER 14: DEVICE MANAGEMENT
Figure 14-2
7600 Card Administration Console
Even if you wish to use SNMP management, you must first connect a
terminal to the serial port, set the VN/bridge configuration, and per
bridge IP address and subnet mask.
Simple Network
Management
Protocol (SNMP)
Simple Network Management Protocol (SNMP) is the standard
management protocol for multi-vendor IP networks. Supporting
transaction-based queries, SNMP formats messages and transmits
information between reporting devices and data-collection programs. It
runs on top of the User Datagram Protocol (UDP), offering a
connectionless-mode service. This allows SNMP to pass management
information before a session is established.
The 7600 Card can be managed through SNMP-based external network
management applications running on a workstation. Transcend
Enterprise Manager, a network management application from 3Com,
manages 7600 Cards by graphically displaying the network. This
graphical interface makes it easier to manage large networks (see
Figure 14-3).
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
7600 Card Management
14-5
Figure 14-3 Transcend Enterprise Manager (SNMP Manager)
Access to the SNMP agent is in-band via any of the Ethernet segments or
ATM port of remote stations. Management of all remote 7600 units is
supported by the SNMP agent, regardless of virtual LAN membership.
Since the 7600 Card is standards-based, other SNMP-based applications,
such as SunNet Manager or HP OpenView can be used.
The SNMP agent is accessed through any of the 100-BaseT Ethernet
ports. It is an in-band connection over IP/Ethernet protocols.
Once the 7600 Card’s IP parameters are set, any SNMP-based network
manager can manage the unit, provided the Management Information
Base (MIB) is installed correctly at the management station.
SNMP Agents
The SNMP agent of the 7600 Card responds to SNMP requests from an
external SNMP manager. Each 7600 Card has one SNMP agent which
monitors objects on the system and reports data to the Administration
Console or a network management system. It acts as an Access Unit
(device) agent for managing generic device objects and configuration,
and as a proxy for all bridge agents (per VN in a device) for managing
bridge-VN specific objects and configuration.
Figure 14-4 shows a 7600 Card being accessed through an SNMP
manager, such as Transcend Enterprise Manager.
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
14-6
CHAPTER 14: DEVICE MANAGEMENT
Figure 14-4 SNMP Manager Protocol Access
Management Information Bases (MIBs)
Managed objects are accessed via a virtual information store, termed the
Management Information Base (MIB).
Information defined in industry-standard, de-facto standard, and
enterprise-specific (private) MIBs supported by the 7600 Card can be
accessed. These MIBs are collections of related managed objects (abstract
representations of resources that are capable of being managed). Some
examples of these resources are error counters, ports, and network
policies. The 7600 Card supports the following SNMP MIBs:
Q
MIB 2
Q
Bridge MIB
Q
AToM MIB
Q
LE Client MIB
Q
RMON MIB
Q
Interface Evolution MIB
Q
NCDCHASS MIB (private)
for managing the ATM port and Virtual LANs.
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
7600 Card Management
14-7
Security
SNMP security is provided through community strings. A community
string is included in each SNMP protocol message sent between external
management applications and the 7600 Card.
The default community strings are:
Access Unit agent Q
read : ‘public AU’
Q
write : ‘private AU’
Proxy to bridge agents Q
read : ‘public’
Q
write : ‘private’
The SNMP agent authorizes requests from the SNMP manager by
comparing the community name in the received packet with the
community string in the 7600 Card.
Local management security is provided through passwords. Three user
access levels exist: read, write, admin.
Virtual Terminal
Protocols
A virtual terminal protocol is a software program, such as Rlogin or
Telnet, that allows establishment of a management session from a PC or
a workstation. Since rlogin and Telnet run over TCP/IP, at least one IP
address must be configured on the 7600 Card to access it with a virtual
terminal protocol.
Terminal emulation differs from a virtual terminal protocol in that it
connects a terminal directly to the serial line (out-of-band).
Figure 14-5 shows a 7600 Card being accessed by a workstation through
a virtual terminal protocol and through a terminal.
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
14-8
CHAPTER 14: DEVICE MANAGEMENT
Figure 14-5 Local Management Protocol Access
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
15
SYSTEM MODES, ATTRIBUTES,
AND TUNING
This chapter explains the administrative and management functions in
the 7600 Card including system modes, attributes and tuning.
Forwarding Modes
Cell Switching
Data frames received from the Fast Ethernet ports pass through the
ZipChip ASIC and are stored in the shared CRAM (Cell RAM) memory. The
CRAM discards all received frames that are not required to be transmitted
on any output (filtered frames). The shared memory structure provides for
optimal utilization of the available memory. Head of Line blocking, which
is caused when frames are queued on input queues, is eliminated by the
fact that there is no input queuing on data frames.
The 7600 Card converts Ethernet frames to ATM sized cells (48 bytes)
upon receipt and then uses cell switching to forward the frames to their
destination addresses. This common format of frames in CRAM makes
switching straightforward. CRAM, under control of ZipChip, is optimized
for storing data cells. Each frame is organized as a linked list of cells. The
cells in the CRAM are either converted back to Ethernet frames when
transmitted on an Ethernet port or to LAN Emulation frames when
transmitted on the ATM port. In this scheme, cell data is never copied
because it is converted to the appropriate format by ZipChip on its way in
and out of CRAM. For more information about Cell Switching in ATM
refer to Chapter 5.
As a frame passes through ZipChip on its way to CRAM, ZipChip makes a
forwarding decision for that frame. The 7600 Card supports two
forwarding modes which are set individually for Ethernet and ATM:
Store-and-Forward Mode
In store-and-forward mode, the frame cannot be forwarded to its
destination address before the last bit has been received. This allows for
the rejection of bad frames.
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
15-2
CHAPTER 15: SYSTEM MODES, ATTRIBUTES, AND TUNING
Cut-Through Mode
Cut-through mode enables a frame to be forwarded to a destination
address even before the entire frame has been received. You can
configure the required number of cells to be received before transmission
starts.
Refer to Figure 15-1 for a comparison of Store-and-Forward and
Cut-Through modes.
Figure 15-1 Cut-through vs. Store-and-Forward Mode
Timeout Tuning
Timeout tuning is used for assigning timeout delays for both hardware
and software. These parameters are used to avoid cells being stuck in the
7600 Card for extended periods of time. This usually occurs when the
frame was not assembled correctly and is too long, or the last cell of the
frame was not received from the ATM ports. The timeout mechanism only
applies to frames arriving from the ATM on their way to the Ethernet
ports or the software. The mechanism gets rid of these frames by
terminating them as erred frames.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Console Passwords
Console Passwords
15-3
The Administration Console requires passwords at the various access
levels: read, write and admin. Admin access is required to change any of
the passwords.
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
A
Technical Support
3Com provides easy access to technical support information through a
variety of on-line and telephone services. This appendix describes these
services.
On-Line Technical
Services
3Com Bulletin Board
Service
3Com offers worldwide product support seven days a week, 24 hours a
day, through the following on-line systems:
Q
3Com Bulletin Board Service (3ComBBS)
Q
Ask3Com on CompuServe
Q
3ComFacts Automated Fax Service
3ComBBS contains patches, software, and drivers for all 3Com products,
as well as technical articles. This service is available via modem seven days
a week, 24 hours a day. To reach the service, set your modem to 8 data
bits, no parity, and 1 stop bit. For the telephone number nearest you see
Table A-1:
Table A-1 Bulletin Board Service
Country
Baud Rate
Telephone Number
Australia
up to 14400 baud
(61) (2) 955 2073
France
up to 14400 baud
(33) (1) 69 86 69 54
Germany
up to 9600 baud
(49) (89) 627 32 188
(49) (89) 627 32 189
Hong Kong
up to 14400 baud
(852) 537 5601
Italy (fee required)
up to 9600 baud
(39) (2) 273 00680
Japan
up to 14400 baud
(81) (3) 3345 7266
Singapore
up to 9600 baud
(65) 534 5693
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
A-2
APPENDIX A: TECHNICAL SUPPORT
Ask3Com on
CompuServe
Ask3Com is a CompuServe-based service containing patches, software,
drivers, and technical articles about all 3Com products, as well as an
interactive forum for technical questions. To use Ask3Com, you need a
CompuServe account.
To use Ask3Com:
1 Log on to CompuServe.
2 Enter go threecom.
3 Press Enter to see the Ask3Com main menu.
3ComFacts
Automated Fax
Service
3Com Corporation's interactive fax service, 3ComFacts, provides data
sheets, technical articles, diagrams, and troubleshooting instructions on
3Com products 24 hours a day, seven days a week. Within this service,
you may choose to access CardFacts for adapter information, or
NetFacts for network system product information.
Q
CardFacts provides adapter installation diagrams, configuration
drawings, troubleshooting instruction, and technical articles.
Document 9999 provides you with an index of adapter documents.
Q
NetFacts provides data sheets and technical articles on 3Com
Corporation's hub, bridge, router, terminal server, and software
products.
Document 8888 provides you with an index of system product
documents.
Call 3ComFacts using your touch-tone telephone. International access
numbers are found in Table A-2.
Table A-2 Automated Fax Service
Telephone Support
Country
Fax Number
Hong Kong
(852) 537 5610
U.K.
(44) (1442) 278279
U.S.
(1) (408) 727 7021
Telephone support is available from both 3Com and your network
supplier.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Telephone Support
Support from 3Com
A-3
If you are unable to receive support from your network supplier, technical
support contracts are available from 3Com.
In the U.S. and Canada, call (800) 876-3266 for customer service.
If you are outside the U.S. and Canada, contact your local 3Com sales
office to find your authorized service provider. For the telephone numbers
see Table A-3.
Table A-3 Telephone Support
Support from Your
Network Supplier
Country
Telephone Number
Country
Telephone Number
Australia
(Sydney)
(61) (2) 959 3020
Mexico
(525)531 0591
(Melbourne)
(61)(3)653 9515
Netherlands
(31)(3)40255033
Belgium
(32)(2)716 4880
Singapore
(65)538 9368
Brazil
(55)(11)241 1571
South Africa
(27)(11)803 7404
Canada
(905)882 9964
Spain
(34)(1)383 1700
France
(33)(1)698 66800
Sweden
(46)(8)632 9100
Germany
(49)(89)627 320
Taiwan
(886)(2)577 4352
Hong Kong
(852)868 9111
United Arab
Emirates
(971)(4)349049
Italy
(39)(2)273 02041
U.K.
(44)(1628)897 000
Japan
(81)(3)3345 7251
U.S.
(1)(408)492 1790
If additional assistance is required, contact your network supplier. Many
suppliers are authorized 3Com service partners who are qualified to
provide a variety of services, including network planning, installation,
hardware maintenance, application training, and support services.
When you contact your network supplier for assistance, have the
following information ready:
Q
Diagnostic error messages.
Q
A list of system hardware and software, including revision levels.
Q
Details about recent configuration changes, if applicable.
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
A-4
APPENDIX A: TECHNICAL SUPPORT
If you are unable to contact your network supplier, refer to Table A-4 on
how to contact 3Com.
Table A-4 Network Supplier Support
Returning Products
for Repair
Country
Baud Rate
Telephone Number
Taiwan
up to 14400 baud
(886) (2) 377 5838
(886) (2) 377 5840
U.K.
up to 14400 baud
(44) (1442) 278278
U.S.
up to 14400 baud
(1) (408) 980 8204
A product sent directly to 3Com for repair must first be assigned a Return
Materials Authorization (RMA) number. A product sent to 3Com without
an RMA number will be returned to the send unopened, at the sender's
expense.
Table A-5 contains the telephone and fax numbers to use, to obtain an
RMA number.:
Table A-5 Obtaining an RMA Number
Country
Telephone Number
Fax Number
U.S. and Canada
(800) 876 3266,
option 2
(408) 764 7120
Europe
(44) (1442) 278000
(44) (1442) 236824
Outside Europe, U.S. and
Canada
(1) (408) 492 1790
(1) (408) 764 7290
Table A-6 lists the local access numbers available within the following
countries:
Table A-6 Local Access Numbers
Country
Fax Number
Country
Fax Number
Australia
800 123853
Italy
1678 99085
Denmark
800 17319
Netherlands
06 0228049
Finland
98 001 4444
Norway
05 01 1062
France
05 90 81 58
Sweden
020 792954
Germany
0130 8180 63
U.K.
0800 626403
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
B
TROUBLESHOOTING
This chapter explains how to identify and correct problems, and how to
perform related diagnostic tasks, such as replacing fuses and cleaning
fiber optic cables.
If you have problems that are not addressed in this chapter, contact
3Com Technical Support or your service person. For Technical Support
information, see Appendix A: Technical Support
Solving Common
Problems
Following are common problems which may arise while working with the
7600 Card. If your problem does not appear on this list, you may want to
view relevant statistics and parameters using the Administration Console
menus (refer to CELLplex 7000 Administration Guide). You can also
contact 3Com Technical Support or your service person (refer to
Appendix E- Technical Support). Also, be sure to read through the release notes.
Terminal Does
Not Show
Anything
If the control terminal is physically connected to the module, but does not
load the Administration Console Menus, verify that your terminal setup
matches the specifications in the Connecting to the Control Terminal
section in Chapter 1. Also, make sure your cable is configured as DTE.
ACT LED Not
Blinking
When the CELLplex 7000 is activated, the ACT LEDs on the 7600 Card
should be blinking. If not, verify that the module is properly inserted into
the chassis of the CELLplex 7000.
Ethernet
Forwarding
Failures (Fx port)
Verify that the Link Status LED is lit green. If not, reconnect the Tx side of
the connection. If that does not eliminate the problem, check that the
connector on the Rx side is properly inserted.
If the Link Status LED is lit, check that the port through which you are
trying to forward data has been enabled. If it has been enabled, check
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
B-2
APPENDIX B: TROUBLESHOOTING
the cabling and connections at the port. Try sending the data through
another port: if you can forward data through the unit via another port, it
indicates a local problem with the first port. Re-examine cabling
connections.
If you still cannot resolve the problem, contact your supplier.
Related Diagnostic
Procedures
Cleaning Dirty
Fiber Optic
Cables
When troubleshooting for problems, you may have to perform minor
procedures to help correct the problem. These procedures are described
below. For more complex operations on the 7600 Card, contact your
service person.
Fiber optic transceivers are sensitive optical devices that need to be
handled carefully. If dirt collects on the fiber optic lens, you may notice
that the LED for an ATM port link status does not light. You may also
notice degraded performance of that port, indicated by an increase in the
physical layer statistics count for that port.
To prevent dust from collecting on the fiber optic lens, keep the dust
covers on the ports at all times when they are not in use. To clean a fiber
optic lens, follow the procedure below:
1 Remove any accumulated dust or debris from the port or connector by
blowing off all surfaces with a canned air duster.
Compressed gas is recommended, such as Chemtronics’ Ultrajet ® or
the Triangle Tool Group’s Liqui-Too!™ Dust-A-Way. Do not use
commercial compressed air or “house air” because of the risk of oil
contamination.
2 Reconnect the cable to the port to see if the dusting corrected the
problem.
3 If the LED still does not appear, or if it lights yellow, continue with steps 5
and 6.
4 Gently wipe the ports with a lint-free, nonabrasive, non-adhesive swab.
Microswabs ™ by Texwipe™ are recommended.
5 Gently wipe the connectors with a lint-free, nonabrasive wipe or pad.
Texwipe™ pads are recommended.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Related Diagnostic Procedures
B-3
Avoid touching all surfaces after cleaning the connectors, and keep all
unused ports covered.
Ne toucher aucune surface après le nettoyage des connecteurs et garder
les pièces inutilisées couvertes.
Vermeiden Sie das Berühren aller Oberflächen nach dem Säubern der
Kontakte und verdecken Sie alle nicht benutzten Öffnungen.
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
C
7600 FAST ETHERNET CARD
SPECIFICATIONS
This chapter contains the specifications of the 7600 Card.
Physical
Interfaces
Height
1¾ in
4.5 cm
Width
17 in
39.5 cm
Depth
11 in
23.5 cm
Weight
±3.3 lb
±1.5 kg
Q
Fast Ethernet
8 or 16 100Base-Fx or 100Base-Tx Ports
Q
Management
1 RS-232 port on CELLplex 7000 switch
Fast Ethernet
Switching
Q
Auto-sensing full duplex/half duplex
Q
Software-selectable, cut-through or store-and-forward mode
Q
Auto sensing 10/100 Mbps
Q
Rate-based flow control
Q
Full rate multicast support
Q
Address table capacity of up to 32k entries
Q
Full rate forward/filter
Q
IEEE 802.1D Spanning Tree protocol (STP) support
Q
Virtual LAN support
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
C-2
APPENDIX C: 7600 FAST ETHERNET CARD SPECIFICATIONS
Environmental
Q
LAN Emulation Client (LEC) support
Q
Local management via the CELLplex 7000’s RS-232 port
Q
Congestion management
Q
MIBs supported: MIB2, Bridge MIB, AToM MIB, LEC MIB, RMON MIB,
Interface Evolution MIB, NCDCHASS MIB (private)
Q
Operating Temperature
32° to 104° F (0° to 40° C)
Q
Operating Humidity
10% to 90% non-condensing
Q
Storage Temperature
-4° to 167° F (-20 to 75° C)
Q
Storage Humidity
10% to 95% non-condensing
Indicators
Management
Q
Fast Ethernet Ports per-port link status and transmit
Q
UnitPower, fail, activity
Q
In-band SNMP over Ethernet
Q
Local Management via CELLplex management
Q
ILMI and OAM support
Q
MIBs supported:
Q
MIB 2
Q
Bridge MIB
Q
AToM MIB
Q
LE Client MIB
Q
RMON MIB
Q
Interface Evolution MIB
Q
NCDCHASS MIB (private)
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
Standards Compliance
C-3
Standards
Compliance
Safety
Q
Agency Certifications:
UL 1950, CSA 22.2 No. 1950,
EN 60950, IEC 825-1 825-2,
PCB UL 94V-0,
PCB ANSI/IPC-RB-276 class 2
Electromagnetic
Emissions (Agency
Certifications)
Q
Designed to Comply with VDE 0871 part 2 class A, EN 55022
Q
AC Protection20 amp circuit breaker
Q
Meets FCC part 15, Subparagraph B, Class A limits, and CISPR-22
Class A limits
Q
Directive complied with: EMC 89/336/EEC as amended by 92/31/EEC
and 93/68/EEC.
Emission: EN50081-1 (EN55022 Class A)
Immunity: EM50082-1 (IEC801-2,-3,-4)
Communications
Protocols
Management
Protocols
RFC 826 ARP, RFC 791 IP, RFC 792 ICMP, RFC 768 UDP, RFC 793 TCP
RFC 1157 SNMP, RFC 1213 MIB2, RFC 1212 Concise, RFC 1212 Traps,
RFC 1695 ATOM MIB
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
GLOSSARY
7600 Card
A 36-port ATM/Ethernet interface card in the CELLplex 7000 chassis.
Asynchronous
Transfer Mode (ATM)
A transfer method used for LAN and WAN. ATM carries voice, video,
and data at speeds up to 2.2 Gbps and can integrate geographically
distant disparate networks. Also called cell relay.
ATM Adaptation
Layer (AAL)
A set of protocols that translate user higher-layer protocols into ATM
format.
ATM Forum
ATM Layer
ATM Member
AU ID
backbone
A consortium of vendors, carriers, and users formed to expedite
industry agreement on ATM interfaces.
The part of the BISDN protocol stack that handles most of the ATM
routing and processing.
An alias given to an ATM address on a specific port in order to avoid
typing in the ATM address 20 octets long.
Unique number assigned to the 7600 Card. May be found through the
Administration Console Menus of the LinkSwitch.
The main segment of a campus network, to which are attached
department networks, or ribs.
Broadcast and
Unknown Server
(BUS)
The Broadcast and Unknown Server handles data sent by a LEC to the
broadcast MAC address, all multicast traffic, and initial unicast frames
which are sent by a LEC before the data direct ATM address has been
resolved.
broadcasting
A common method of information transmission in which every port on
the network receives the packet being sent, though only the port with
the proper address passes it on to the user.
bridge
Device connecting between two networks which filters and forwards
data between the networks according to their destination address.
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
2
GLOSSARY
cell
CELLplex 7000 Switch
An ATM Layer protocol data unit (PDU) characterized by fixed, rather
than variable, length payloads. The standard ATM cell is 48 bytes of
payload with 5 bytes of header.
A high-performance, modular ATM switch.
Cell Loss Priority
(CLP)
A bit in the ATM cell header indicating that if there is a need to discard
a cell, the cell with the CLP bit marked is to be discarded.
collision
Overlapping transmission of two or more nodes onto media. All data is
unusable.
connection
An ATM connection consists of the concatenation of ATM Layer links in
order to provide an end-to-end information transfer capability to access
points.
connectionless
communications
A form of packet-switching that relies on global addresses in each
packet rather than on predefined virtual circuits.
connectionoriented
communications
A form of packet-switching that requires a predefined circuit from
source to destination to be established before data can be transferred.
Data
Communications
Equipment (DCE)
The equipment providing functions that establish, maintain and
terminate a data transmission connection.
Data Terminal
Equipment (DTE)
The equipment connected to the common carrier communications
facility. The DTE is typically a computer system or terminal.
end system
Ethernet
header
IEEE 802.3
IEEE 802.1d
A system where an ATM connection is terminated or initiated. An
originating end system initiates the ATM connection, and a terminating
end system terminates the ATM connection.
A CSMA/CD, 10 Mbps, local area data network, developed by Xerox
Corporation. It is one of the most popular LANs in use.
Protocol control information located at the beginning of a protocol
data unit.
IEEE standard for Ethernet local area networks.
IEEE standard for bridging.
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
GLOSSARY
3
in-band
Transmission of auxiliary information, e.g., management messages over
the media also used by the system users.
Internet Protocol (IP)
The protocol governing packet forwarding within the Transmission
Control Protocol/Internet Protocol (TCP/IP) suite of standards developed
and used on the Internet.
Internet Protocol
address (IP address)
A unique identifier for a machine attached to a network made up of
two or more interconnected local area or wide area networks.
Local Area Network
(LAN)
A data communications network spanning a limited geographical area,
such as a single building or campus. It provides communication
between computers and peripherals. LANs are distinguished by their
small geographical size, high data rate, and low error rate.
LAN Emulation
A way for legacy LANs and all higher-layer protocols and applications to
integrate transparently with ATM networks.
LAN Emulation Client
(LEC)
The LAN Emulation Client is the entity in end systems which performs
data forwarding, address resolution, and other control functions.
LAN Emulation
Configuration Server
(LECS)
Assigns individual LECs to different Emulated LANs. The LECS allows
the LEC to automatically configure.
LAN Emulation
Server
LinkSwitch 2700
LM
Management
Information Base
(MIB)
Network to Network
Interface (NNI)
Operation and
Maintenance cell
(OAM)
Implements the control coordination function for the Emulated LAN. In
addition, it provides a facility for registering and resolving MAC
addresses and/or route descriptors to ATM addresses.
3Com Ethernet-to-ATM switch used to connect Ethernet network
devices to each other and to an ATM backbone.
Local management of a network device, via a connected terminal.
A database of network management information that describes the
specifics of individual network components.
The interface between two ATM network nodes.
A cell that contains ATM maintenance and performance monitoring
information. It does not form part of the upper layer information
transfer.
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
4
GLOSSARY
out-of-band
Transmission of auxiliary information e.g., management messages, over
a media other than that used by the system users.
point-to-point call
A two-way call or connection that has one source and one destination.
point-to-multipoint
call
protocol
A one-way call or connection that has only one source, but may have
many destinations.
A set of rules for communicating between communication devices. The
rules dictate format, timing, sequencing, and error control.
Protocol Data Unit
(PDU)
A unit of data specified in a layer protocol and consisting of protocol
control information and layer user data.
Permanent Virtual
Connection (PVC)
. A basic connection method that requires the user to define each
connection manually.
router
RJ-21port
server
Simple Network
Management
Protocol (SNMP)
Switched Virtual
Connection (SVC)
topology
A device that connects two or more remote networks by selectively
forwarding messages between them. A router differs from a bridge in
that it selectively forwards information between the networks, based
on layer 3 protocols.
50-pin Telco connector on 7400 Interface Card that supports 12
10BaseT ports for high-density connections.
A computer that provides clients with application and network services.
Servers are shared by multiple users.
A protocol originally designed to be used in managing TCP/IP-based
internets. SNMP is presently implemented on a wide variety of
computers and networking equipment and may be used to manage
many aspects of network and end-station operation.
An ATM standard signaling protocol that automatically defines
connections as they are needed, and discards them when desired.
The physical or logical placement of stations on a network in relation to
one another.
Virtual Channel
Identifier (VCI)
Part of the identifier of a particular virtual circuit in the ATM fabric.
Virtual Path
Identifier (VPI)
Part of the identifier of a particular virtual circuit in the ATM fabric.
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
GLOSSARY
User Network
Interface (UNI)
Wide Area Network
(WAN)
5
The UNI interconnects an ATM user with an ATM switch.
Data communications network spanning very large geographical areas.
abtthgde.book Page 1 Tuesday, June 23, 1998 10:29 AM
INDEX
INDEX
Numbers
100BASE-Fx 2-5
100BASE-Fx port 1-1
100BASE-Tx 2-5
100BASE-Tx port 1-1
3Com Bulletin Board Service A-1
3ComFacts Automated Fax Service A-2
7600 Card
bridge setup 12-18
7600 Fast Ethernet Interface Card
About This Guide 1
Functional Overview 1-1
A
AAL5 layer
octets 7-2
unicast frames 7-2
AC protection C-3
access unit
community strings 14-7
SNMP agent 14-5
active LED not blinking B-1
active LEDs
system status 2-8
address resolution 12-12
Admin vLAN management
configuring 3-9
administration console 14-1
management capabilities 4-1
menu system 4-1
administrative status
ATM port 7-2
enable on ATM port 7-9
Fast Ethernet port 6-3
agency certifications C-3
aging time
Bridge 6-9
LE_ARP cache 12-14
LEC 8-8, 12-17
allowed ports 11-8
Ask3Com on CompuServe A-2
ATM
basic concepts 12-2
cell switching 12-2
fixed length cell 12-2
ILMI MIB 12-4
internal connection 5-2
protocol stack layer 12-2
ATM Adaptation Layer, see AAL
ATM address
BUS 8-5, 12-10
LECS 8-4, 8-6, 12-9
LES 8-4, 8-5, 12-10
ATM port
administrative status 7-2
enable administrative status 7-9
octets 7-2
operational status 7-2
statistics 7-2, 7-3
unicast 7-2
Auto-sensing 1-4
B
blocking
static address on port 6-19, 11-8
Bridge
aging time 6-9
attaching Fast Ethernet port to 5-2
attaching internal ATM port 5-3
attributes and statistics 6-8
Fast Ethernet port assigned to 5-2
Forwarding database 6-12
forwarding logic 12-14
in 7600 Card 12-10
learned discards 6-9
MAC address 6-9
STP Attributes 6-22
Bridge ATM address
display 7-3
ILMI state 7-4
update 7-4
Bridge parameters
port-dependent 11-11
port-independent 11-11
Bridge port
delay discarded frames 6-11
disable for management 6-27
discarded frames 6-10
excessive discarded frame 6-11
1
abtthgde.book Page 2 Tuesday, June 23, 1998 10:29 AM
2
INDEX
Forwarding database 6-12, 6-14
frame traffic statistics 6-10
frames 6-10
mapping to Ethernet ports 6-8
number 6-9
STP Attributes 6-26
Bridged-LAN environments 11-12
Broadcast and Unknown Server, see BUS
broadcast attributes
display 6-5
updating 6-6
broadcast throttling
disabling 6-6
Bulletin Board Service A-1
BUS
ATM address 8-5
configuration information 8-4
multicast forward VCC 8-5, 12-10
multicast send VCC 8-5, 12-10
unicast frames 8-17, 8-18
C
cable type
shielded twisted pair (STP) 11-4
unshielded twisted pair (UTP) 11-4
card specifications
specifications C-1
Carrier Sense Multiple Access with Collision Detection,
see CSMA/CD
cell
discarding 13-4
cell switching 12-11
cleaning dirty fiber optic cables B-2
cleaning fiber optic transceivers B-2
communications protocols C-3
community strings
access unit 14-7
proxy to bridge agent 14-7
SNMP security 14-7
CompuServe, Ask3Com A-2
config VCC
LECS 8-4, 12-9
configuring
7600 Card 2-5
Admin vLAN management 3-9
default gateway 3-10
ELANs 3-10
IP address 3-10
LE Client 3-8
LE parameters 3-7
LECS address 3-7
management 3-10
network prefix 3-6
UNI/NNI parameters 3-7
Virtual LAN 3-8, 3-10
connecting
local management terminal 2-6
network devices 2-5
connection
RS-232 2-6
via the CELLplex 7000 switch 2-6
connection status 2-9
connector
SC 2-5
STP 2-5
console event messages
disabling 10-14
console password 15-3
context 3-10, 4-3
changing 4-3
control direct VCC
LES 8-5, 12-10
control distribute VCC
LES 8-5, 12-10
control information
in-band 12-16
control time-out
LEC 12-16
conventions
notice icons, About This Guide 2
typographical 2
CSMA/CD 11-1
cut-through mode 10-7, 15-2
D
default gateway 9-2
configuring 3-10
disable
Bridge port 6-27
broadcast throttling 6-6
console event messages 10-14
Fast Ethernet port 6-5, 11-5
STP 6-21, 11-10
discarding cells 13-3
display
ATM port attributes and statistics 7-2
Bridge ATM address 7-3
Bridge attributes and statistics 6-8
Bridge STP attributes 6-22
broadcast attributes 6-5
context 4-3
current LEC configuration 8-4
Fast Ethernet port attributes 6-2
FDB entries 6-12
FDB learned entries 6-14
frame traffic statistics on Bridge port 6-10
hardware configuration 10-5
IP configuration 9-2
abtthgde.book Page 3 Tuesday, June 23, 1998 10:29 AM
INDEX
LEC control-frame statistics 8-14
LEC operational parameters 8-8
LEC statistics 8-2
main menu 4-1
SNMP configuration 9-4
software download status 10-3
software time-out parameters 10-8
software version 10-2
STP attributes for Bridge port 6-26
STP enable status 6-21
time-out delays 10-11
traffic management clients 7-6
traffic management configuration 7-5
display FDB static entries 6-15
documentation
how to read 2
road map 3
E
ELAN
assigning name to 5-2
Components 12-5
configuring 3-10
connected to Bridge 5-2
connections 12-7
corresponding to vLAN 12-18
data transmission on 12-15
update name 8-6
ELAN name
LES 12-9
electromagnetic emissions standards C-3
Emulated LAN, see ELAN
environmental specifications C-2
ethernet forwarding failure B-1
Ethernet switching
features 1-4
specifications C-1
Explicit Forward Congestion Indication
traffic management 13-3
explicit rate control
traffic management 13-4
F
fail LEDs
system status 2-8
Fast Ethernet
LAN 11-2
LED display 2-8
physical modules 1-1
status indicators 2-8
Fast Ethernet backbone 1-5
Fast Ethernet port
10/100 Mbps transmission speed 11-3
administrative status 6-3
assigned to Bridge 5-2
attaching to Bridge 5-2
attributes and statistics 6-2
auto-negotiation 11-2
autonegotiation 6-7
broadcast frames 6-3
capabilities 11-2
configuration 1-1
context 3-10, 4-3
disabling 6-5, 11-5
discarded frames 6-3
duplex mode 6-7
errored frames 6-3
full/half duplex transmission mode 11-2
Fx connection 1-3
indicators C-2
link status 2-9
MAC address 6-3
mapping to Bridge ports 6-8
monitoring 11-5
multicast frames 6-3
numbering 1-1
octets 6-3
packet status 2-9
speed 6-7
Tx connection 1-3
unicast frames
unknown frames 6-4
updating attributes 6-7
fax service A-2
flash memory
reset 10-12
flooding mode 12-14
flush protocol 12-16
forward-delay-time
LE_ARP cache 12-14
Forwarding database 11-7
add static address 6-19
allowed-to static entries 6-16
blocking static address 6-19
Bridge 6-12, 6-14
Bridge port 6-12, 6-14
display all entries 6-12
display learned entries 6-14
display static entries 6-15
entry status 6-16
MAC address 6-12, 6-14, 6-16
member ID 6-16
received port static entries 6-16
remove static address 6-20
status 6-12
forwarding logic
Bridge 12-14
forwarding modes 15-1
3
abtthgde.book Page 4 Tuesday, June 23, 1998 10:29 AM
4
INDEX
frame traffic statistics 6-10
front panel
with physical modules 1-1
functional overview 1-1
G
guide
scope 1
typographical conventions 2
H
hardware configuration 10-5
hardware time-out delay 10-11, 15-2
update 10-11
hardware time-out parameters 10-8
how to read documentation 2
humidity
operating C-2
storage C-2
I
implicit rate control
traffic management 13-3
in-band management 14-2
indicators
specifications C-2
installing
7600 Card 2-4
Fast Ethernet physical module 2-5
integrated setup
operation 3-5
internal ATM port
attaching to Bridge 5-3
IP address 9-2
configuring 3-10
IP configuration 9-2
Bridge 9-2
L
LAN
Fast Ethernet 11-2
LAN Emulation
components see LE components
LAN Emulation Address Resolution Protocol, see LE_ARP
LAN Emulation Client, see LEC
LAN Emulation Server, see LES
LE Client
configuring 3-8
LE parameters
configuring 3-7
LE_ARP 12-12
LE_ARP cache
aging 12-14
aging time 12-14
LE_ARP response 12-12
LE_ARP, see LAN Emulation Address Resolution Protocol
learning addresses 12-13
learning station addresses 11-7
LEC 12-6
aging time 8-8, 12-17
broadcast frames 8-2
configuration and status 8-4, 12-9
connection state 8-2
control frame statistics 8-14
control time-out 12-16
control-frame statistics 8-14
discards 8-3
errored frames 8-3
forward delay time 8-8
ID 8-4
multicast frames 8-2
octets 8-2
operational parameters 8-8
parameters 12-16
proxy 12-13
state 8-2
statistics 8-2
topology change flag 8-8
unicast frames 8-2
unknown frames 8-3
VCC time-out 12-17
LEC control-frame statistics
reset 8-17
LEC ID
LES 12-9
LECS
ATM address 8-4, 8-6
LAN Emulation Configuration Server, see LECS
ATM address via ILMI 8-7
config VCC 8-4, 12-9
configuration information 8-4
LECS address
configuring 3-7
LED display 2-7
LEDs 1-3
LES
ATM address 8-4, 12-10
configuration information 8-4
control direct VCC 8-5, 12-10
control distribute VCC 8-5, 12-10
ELAN name 12-9
LEC ID 12-9
populating directory 12-13
LES ATM address
update 8-7
LES directory
abtthgde.book Page 5 Tuesday, June 23, 1998 10:29 AM
INDEX
populating 12-6
Link status 2-9
LM security 14-7
local management terminal 2-6
Local Management, see LM
locating information in documents 3
M
MAC address 6-3, 12-13
Ethernet ports 6-3
Forwarding database 6-12, 6-14, 6-16
management
configuration 3-10
in-band 14-2
out-of-band 14-2
specifications C-2
Management Information Base C-2
supported MIBs 14-6
management protocols C-3
Maximum Transfer Unit, see MTU
maximum-unknown-frame-count. 12-15
maximum-unknown-frame-time 12-15
menu system 4-1
menus
access to submenus 4-4
key functions 4-4
selecting options 4-3
MIB 14-6
MIBs supported 1-4
multicast forward VCC
BUS 12-10
multicast frames 12-16
multicast send VCC
BUS 12-10
N
network devices 2-5
network prefix
configuring 3-6
network resource management
traffic management 13-4
Network to Network Interface, see NNI
NMS IP address
update 9-5
NNI
in ATM 12-2
normal operation 2-8
O
octets
ATM port 7-2
On-Line Technical Services A-1
3Com Bulletin Board Service A-1
3ComFacts Automated Fax Service A-2
Ask3Com on CompuServe A-2
operating humidity C-2
operating temperature C-2
operational status
ATM port 7-2
port 6-3
out-of-band management 14-2
P
Packet status 2-9
password
admin-access 10-14
read-access 10-13
write-access 10-13
passwords 14-7, 15-3
Permanent Virtual Channels, see PVC
physical module 1-1
physical specifications C-1
populating LES directory 12-13
port state
blocking 11-8
learning 11-10
listening 11-10
port status
operational 6-3
power LEDs
system status 2-8
power-on self-test 2-8
power-up phase 2-8
protocol
communications C-3
management C-3
protocol stack
ATM layer 12-2
protocols
virtual terminal 14-7
proxy LEC 12-13
proxy to bridge agent
community strings 14-7
R
ready frames 12-16
reboot 10-15
registering MAC addresses 12-13
repairing products A-4
Resource Management cell usage 13-5
Resource Management Cells, see RM-cells
returning products for repair A-4
RJ-45 connector 1-3
rlogin 14-1
RM-cells 13-1
5
abtthgde.book Page 6 Tuesday, June 23, 1998 10:29 AM
6
INDEX
road map of documentation 3
S
safety precautions 2-1
safety standards C-3
SC connector 1-3
scope of this guide 1
security
SNMP 14-7
selective cell discarding 13-4
Serial Port Settings 2-6
server farm 1-7
setup
full 3-2
integrated 3-2
multi-context 3-10
switch 3-2
Simple Network Management Protocol (SNMP) 14-3
Simple Network Management Protocol, see SNMP
SNMP
overview 14-4
SNMP agents
SNMP configuration 9-4
Bridge 9-4
NMS address 9-4
SNMP security
community strings 14-7
software
erase from flash 10-4
software download
from local 10-4
from network 10-3
TFTP 10-3
software time-out delay 10-11, 15-2
update 10-12
software time-out parameters 10-8
software version
display 10-2
Spanning Tree Protocol
disabling 11-10
overview
path between LANs 11-9
reconfiguring 11-10
specifications
communications protocols C-3
electromagnetic emissions standards C-3
environmental C-2
Ethernet switching C-1
indicators C-2
interfaces C-1
management C-2
management protocols C-3
physical C-1
safety standards C-3
standards compliance C-3
standards compliance C-3
static addresses 11-8
permanency 11-8
statistics
ATM port 7-2, 7-3
Bridge 6-8
Fast Ethernet port 6-2
frame traffic on Bridge port 6-10
LEC 8-2
LEC control-frame 8-14
link and physical layer parameters at UNI 12-4
reset LEC control-frame 8-17
traffic rate 13-5
status
Forwarding database 6-12
storage humidity C-2
storage temperature C-2
store-and-forward
in Bridge 11-6
mode 10-7, 15-1
STP
disable 6-21
display attributes 6-22
display enable status 6-21
STP attributes
display for Bridge-port 6-26
update Bridge-forward-delay 6-25
update Bridge-hello-time 6-24
update Bridge-priority 6-24
STP Bridge-port attributes
update Bridge-path-cost 6-28
update Bridge-port-priority 6-27
STP, see Spanning Tree Protocol
subnet mask 9-2
update 9-4
support
from 3Com A-3
from network supplier A-3
supported MIBs C-2
system administration console 14-1
system configuration mode 10-6
system state
hardware fault 2-7
normal operation 2-7
power-up 2-7
software fault 2-7
system states 2-7
T
technical support A-1
telephone support A-2
support from 3Com A-3
support from network supplier A-3
abtthgde.book Page 7 Tuesday, June 23, 1998 10:29 AM
INDEX
Telnet 14-1
temperature
operating C-2
storage C-2
TFTP software download 10-3
time-out
display 10-11
time-out tuning 15-2
traffic management 13-3
connection admission control 13-4
control cells 13-1
display clients 7-6
display configuration 7-5
enabling 7-6
Explicit Forward Congestion Indication 13-3
explicit rate control 13-4
flow control 13-2
flow rate adjustment 13-6
implicit rate control 13-3
network resource management 13-4
overview 13-1
selective cell discarding 13-4
standard 1-5
traffic shaping 13-5
usage parameter control 13-4
traffic rates shaping 13-5
definition 13-5
traffic status 2-9
Transcend Enterprise Manager 1-5
transparent bridge 11-6
troubleshooting
related diagnostic procedures B-2
typographical conventions 2
U
Ucast. See Unicast frames
UNI
in ATM 12-2
UNI see User Network Interface
UNI version
update 7-9
UNI/NNI parameters
configuring 3-7
unicast
ATM port 7-2
unicast frames
data direct 12-15
unknown 12-15
unknown address
defintion 12-13
unknown unicast flooding mode 12-14, 12-15
unknown unicast-flooding mode
update 8-17
update
admin-access password 10-14
Bridge ATM address 7-4
Bridge connection-completion-timer 8-13
Bridge forward-delay-time 8-11
Bridge LE-ARP response-time 8-11
Bridge path-switching-delay 8-12
Bridge topology-change-flag 8-11
Bridge-aging-time 6-10
broadcast threshhold 6-6
control time-out 8-9
default gateway 9-3
ELAN name 8-6
Fast Ethernet port attributes 6-7
hardware time-out delay 10-11
IP Address for Bridge 9-2
LEC aging-time 8-10
LEC operational parameters 8-9
LECS address 8-6
LES ATM address 8-7
NMS IP address 9-5
read-access password 10-13
software time-out delay 10-12
static address 6-19
store-and-forward mode 10-7
STP Bridge-forward-delay 6-25
STP Bridge-hello-time 6-24
STP Bridge-path-cost 6-28
STP Bridge-port attributes 6-27
STP Bridge-priority 6-24
subnet mask 9-4
system configuration mode 10-6
UNI version 7-9
unknown unicast-flooding mode 8-17
VCC time-out period 8-10
write-access password 10-13
User Datagram Protocol (UDP) 14-4
user interfaces 14-1
User Network Interface, see UNI
V
VCC
data direct 12-13
VCC time-out
LEC 12-17
VCI
virtual channel connection 12-3
Virtual Channel Connection, see VCC
Virtual Channel Identifier, see VCI
Virtual LAN
box-wide 3-2
configuring 3-8, 3-10, 5-1
connecting local segments to 12-18
for Workgroup 12-21
in 7600 Card 12-18
7
abtthgde.book Page 8 Tuesday, June 23, 1998 10:29 AM
8
INDEX
overview 12-17
Virtual LANS, see vLANs
Virtual Path Connection see VPC
Virtual Path Identifier, see VPI 12-3
virtual terminal protocols 14-1, 14-7
VPC 12-3
Z
ZipChip ASIC
7600 Card 12-11
">
/