MultiTech CC1600 Series modem rack Owner's Manual
Multitech CC1600-11L
The Multitech CC1600-11L is a modem rack that can house up to 16 modems in a single standard 19-inch rack enclosure. It is designed to accommodate a variety of modems and is capable of redundant power for uninterrupted service. The CC1600-11L is available for use with either universal AC input or -48v DC power.
Capabilities:
- Accommodates up to 16 modems
- Redundant power for uninterrupted service
- Universal AC input or -48v DC power
- Standard RJ11 jacks
- Easy to monitor data communications with individual LEDs for each modem
- 19" wide, 7" high, and 15" deep
Annonce
Annonce
CC1600 -Series
Card Cages
CC1600-Series
Modem Racks
Owner's Manual
Owner’s Manual
82047705 Revision F
CC1600-Series Modem Rack
This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved.
Copyright © 1998, by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose.
Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
Record of Revisions
Revision Description
D Manual revised to include new power requirements and
(11/18/96) clarification on 48V power leads.
E Manual revised to include safety warnings and CE mark
(10/13/97) information.
F
(4/13/98)
Manual revised. All pages at revision F.
Patents
This Product is covered by one or more of the following U.S. Patent
Numbers: 5.301.274; 5.309.562; 5.355.365; 5.355.653; 5.452.289;
5.453.986. Other Patents Pending.
TRADEMARKS
Multi-Tech and the Multi-Tech logo are trademarks of Multi-Tech
Systems, Inc.
Multi-Tech Systems, Inc.
2205 Woodale Drive
Mounds View, Minnesota 55112
(612) 785-3500 or (800) 328-9717
Fax (612) 785-9874
Technical Support (800) 972-2439
BBS (612) 785-3702 or (800) 392-2432
Internet Address: http://www.multitech.com
Fax-Back (612) 717-5888
Contents
Chapter 1 - Introduction and Description
Introduction ................................................................................ 6
Description ................................................................................. 6
Technical Specifications ............................................................. 8
Chapter 2 - Installation
Introduction .............................................................................. 10
Safety Warnings ....................................................................... 10
Safety Recommendations ........................................................ 11
Installation ................................................................................ 12
Power Supply Installation ......................................................... 16
Powering Up ............................................................................. 17
Chapter 3 - Service, Warranty and Tech Support
Introduction .............................................................................. 20
Limited Warranty ...................................................................... 20
Tech Support ............................................................................ 21
Recording Rack Information .............................................. 21
Service ............................................................................... 22
The Multi-Tech BBS ................................................................. 23
To log on to the Multi-Tech BBS ......................................... 23
To Download a file .............................................................. 23
About the Internet ..................................................................... 25
About the Multi-Tech Fax-Back Service ................................... 25
Appendices
Appendix A - Safety Requirements ........................................... 28
Appendix B - Cabling ................................................................ 32
iii
iv
CC1600 -Series
Card Cages
Chapter 1 - Introduction and Description
CC1600-Series Owner's Manual
Introduction
Welcome to the world of data communications. You have one of the finest modem racks made today. This owner's manual provides information that will help you to install and operate your Multi-Tech CC1600-Series Modem Rack. This manual covers the description of the modem rack, its technical specifications, power supply, procedures for modem installation, RS232C and phone line connections and powering up mode.
Description
The Multi-Tech CC1600-Series modem racks are designed to house up to 16 modems in a single standard 19-inch rack enclosure. The modem rack accommodates a variety of modems, is capable of redundant power for uninterrupted service, and is available with either standard RJ11 jacks
(models with "-11L" suffix) or RJ21 multi-line jacks (models with "-21" suffix). Both versions are available for use with either universal AC input or -48v DC power.
6
1
0
1
0
Figure 1-1. CC16xx Rack
Chapter 1 - Introduction and Description
The CC1600 is a generic rack that accommodates a variety of rackmount modems and DSUs. The CC1628 series is designed specifically for V.34 modems. Both rack models come in -11L and -21 versions. The -11L version connects to standard RJ11 telephone phone cords. The -21 version has three 50-pin connectors for dial-up and 2-wire or 4-wire leased lines. Both models are equipped for universal AC input or
-48v DC. Finally, both models are available with either a single power supply or dual (redundant ) power supplies for uninterrupted power. A single power supply can maintain a full complement of modems.
The CC1600-series rack makes it easy for you to monitor your data communications. Each modem has its own set of LEDs, with separate indicators for Receive Data, Transmit Data,
Carrier On, Speed, Off Hook, Data Terminal Ready, Ring
Indicator, and Error (Out-of-Service and Busy).
The rack measures 19" wide, 7" high, and 15" deep. The rack is usually mounted in the same cabinet as your computer, or can be enclosed in a separate cabinet of its own. Modems are installed by simply opening the rack front door and sliding in the modems. RS232C cables and phone cords are connected to modem connectors at the back of the rack.
7
CC1600-Series Owner's Manual
Technical Specifications
Rack Capacity: Up to 16 modems
Connectors: IEC 320 Inlet Power Connector
Dimensions:
Weights:
19" wide x 7" high x 15" deep
48.26cm wide x 17.8cm high x 38.1cm deep
Rack with one power supply: 21lbs. (9.5 kg)
Rack with two power supplies and 16 modems: 30 lbs. (13.6 kg)
Power Supply
Input: PS1600 - 90 to 245 Volts AC, 2.0 Amps
PS1648 - -40 to -56 Volts DC, 2.5 Amps
Power
Consumption:
Ambient
Temperature:
Indicators:
70 watts, for a fully loaded rack
32° to 120° F (0° to 50° C)
One LED per power supply
8
CC1600 -Series
Card Cages
Chapter 2 - Installation
CC1600-Series Owner's Manual
Introduction
Multi-Tech rackmount modems are generally used in a central site computer environment (i.e., connected to a mini or mainframe computer) to automatically answer incoming calls from remote users.
Command mode should be disabled unless you wish to give the modem commands. Leaving command mode enabled offers the possibility of a user calling into the modem and reconfiguring it, or causing it to dial out. Refer to the appropriate modem owner’s manual to configure the modem for your application.
Safety Warnings
1.
Never install telephone wiring during a lightning storm.
2.
Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
3.
Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
4.
Use caution when installing or modifying telephone lines.
5.
Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electrical shock from lightning.
6.
Do not use the telephone to report a gas leak in the vicinity of the leak.
10
Chapter 2 - Installation
Safety Recommendations
The following safety recommendations should be observed when installing Multi-Tech CC1600-series modem racks.
• Ensure proper installation of the CC1600-series modem racks in a closed or multi-unit enclosure by following the recommended installation as defined by the enclosure manufacturer. Do not place the CC1600-series modem rack directly on top of other equipment or place other equipment directly on top of the CC1600-series rack.
• If installing the CC1600-series modem rack in a closed or multi-unit enclosure, ensure adequate airflow within the rack so that the maximum recommended ambient temperature is not exceeded.
• Ensure that the CC1600-series modem rack is properly connected to earth ground via a grounded power cord. In the event that a power strip is used, ensure that the power strip provides adequate grounding of the attached equipment.
• Ensure that the mains supply circuit is capable of handling the load of the CC1600. Refer to the power label on the equipment for load requirements.
• Maximum recommended ambient temperature for the
CC1600 is 50° C (120° F).
• This equipment should be installed only by properly qualified service personnel.
• Only connect like circuits. In other words, connect SELV
(Secondary Extra Low Voltage) circuits to SELV circuits
11
CC1600-Series Owner's Manual and TN (Telecommunications Network) circuits to TN circuits.
Installation
Perform the following procedure to install the CC1600-series modem rack and install up to 16 modems in the rack.
1.
Unpack the rack and check all items against the shipping list to ensure that you have received the correct items.
Rack Components
A.
B.
C.
Rack
Power Cord
Owner's Manual
2.
Inspect the rack for visible shipping damage. If damage is observed, do not power-on the rack; contact Multi-Tech's
Technical Support for advice (refer to Chapter 3).
3.
If no damage is observed, mount the rack in a standard
19-inch wide rack enclosure. Mounting hardware should be provided with the rack enclosure.
4.
If power supply is not installed in rack, refer to the following section for power supply installation. If the power supply is already installed, proceed to step 5.
5.
Open the rack front door.
6.
Unpack the modems to be installed in the rack.
7.
Refer to the RackMounted Modem Owner's Manual for the switch settings and parameters which pertain to your application (dial-up/leased-line).
8.
Slide a modem into one of the 16 available slots. The component side of the card should be to the right as in
Figure 2-1. The modem's gold edge connector will mate with the rack's backplane. The edge connector is offset vertically so the modem cannot be inserted upside down.
12
Chapter 2 - Installation
Slot 1
Modem
Component
Side
Rack
Door
Figure 2-1. Modem Installation
9.
Firmly seat the modem card into the backplane connector.
10. Repeat steps 7 through 9 for the remaining modems.
11. Connect an RS232C cable to the DB25 connector (25-pin female connector) on the backplane of the rack. Start by connecting the RS232C cable to the right-most channel
(slot 1) as viewed from the back of the rack.
Note: Any cables connected to the computer should be shielded to reduce radio frequency interference. Keep track of which computer channel belongs to which modem in the rack. Most computer interface buses are grouped in sixteens, which enables you to match modem and computer channel numbers.
13
CC1600-Series Owner's Manual
16
15
14
13
12
11
10
9
8
7
6 5
4
3
2
1
Slot Number
DB25 Connector
(SELV Circuit)
RJ11 Connector
(TN Circuit)
Negative
Lead
Positive
Lead
48 Volt Power Supply
Figure 2-2. Cable Connections
12. If you are connecting your phone line directly to an RJ11 jack on the backplane of the rack, plug the telephone cord into the RJ11 jack on the appropriate modem.
If you are connecting a -11L rack to leased lines or leased lines with dial back-up, a Dial/Leased Splitter is required between the leased line jack and the RJ11 jack on the backpanel of the rack. The single RJ11 plug connects to the RJ11 jackon the backpanel of the rack. The RJ11 jack labeled Leased connects to the leased line connector. If dial-back up is used, the RJ11 jack labeled dial should be connected to the dial-back up line.
Note: The Dial/Leased Splitter is a custom part (a "Y" cable) which includes an RJ11 plug that plugs into the
RJ11 jack on the backplane of the rack and is a 5-inchlong six-conductor cable terminated at two RJ11 jacks.
One jack is labeled Leased and the other Dial.
14
Chapter 2 - Installation
If you are connecting your phone lines (-21 series rack) to the 50-pin connector on the backplane of the rack, plug the appropriate phone cable into the appropriate 50-pin connector (RJ21X). RJ21X connectors are TN circuits.
Note: Three 50-pin connectors are mounted on the back of the -21 series rack backplane. The left 50-pin connector (labeled Dial-Up/2-Wire Leased Line) is used to connect all the modems in the -21 series rack to dial-up phone lines. When 4-wire leased lines are being connected, the two right 50-pin connectors (labeled 2-wire
Lease Line/4-wire Transmit Pair on the right and 4-wire
Receive Pair in the center) are used to connect the rack to leased lines. When connecting to 2-wire leased lines, you must first determine if your modem has dial back-up capability. If it does, then use the right connector. If it does not, then use the left (2-wire Lease Line) connector.
13. If an AC power source is being used, plug the AC power cord supplied with the rack into the power cord connector on the back of the rack and to a live AC outlet.
If a DC power source is being used, connect the negative lead from the DC supply to the left terminal on the terminal block on the back of the rack and the positive lead from the DC supply to the right terminal on the rack.
15
CC1600-Series Owner's Manual
Power Supply Installation
The CC1600-series modem rack is configured with either a single power supply or two (hot-swappable, redundant) power supplies. A single power supply can maintain a full complement of 16 modems or DSUs. To install a power supply, perform the following procedure.
1.
Unpack the power supply and check for visible shipping damage. If damage is observed, do not install the power supply; contact Multi-Tech's Technical Support for advice
(refer to Chapter 3).
16
Power Supply
Power Supply
Cover
1
0
Figure 2-3. Power Supply Installation
2.
Using a Phillips screwdriver, loosen the two power supply cover mounting screws and remove the cover from the slot where you intend to install the power supply.
3.
Slide the power supply into the two mating card guides and firmly seat the power supply connectors into the backplane connectors.
Chapter 2 - Installation
4.
With a Phillips screwdriver, tighten the power supply screws.
Warning: If only a single power supply is used, then the unused opening should have a power supply cover in place.
5.
If a second power supply is being installed, repeat steps 1 through 4.
6.
Return to the rack installation procedure to continue installing the rack.
Powering Up
Once the power switch is turned on, the green LED on the power supply(s) should be lit and the modems perform a diagnostic self-test, indicated by the speed LEDs flashing in sequence for approximately two seconds. If none of the modems have power to them or the power supply LED(s) is not lit, check the power cord connection and check that the AC outlet is live. If one of the green power supply LEDs on the front of the rack is not lit, then one of the redundant power supplies may be defective or not installed correctly (i.e., not making proper contact).
17
CC1600-Series Owner's Manual
18
CC1600 -Series
Card Cages
Chapter 3 - Service, Warranty and Tech Support
CC1600-Series Owner's Manual
Introduction
This chapter starts out with statements about your Multi-Tech
CC1600-series modem rack 2-year warranty. The next section, Tech Support, should be read carefully if you have questions or problems with your CC1600-series modem rack.
It includes the technical support telephone numbers, space for recording your product information, and an explanation of how to send in your CC1600-series modem rack should you require service. The final three sections explain how to use our bulletin board service (BBS), and get support through CompuServe and the Internet.
Limited Warranty
Multi-Tech Systems, Inc. (“MTS”) warrants that its products will be free from defects in material or workmanship for a period of two years from the date of purchase, or if proof of purchase is not provided, two years from date of shipment.
MTS MAKES NO OTHER WARRANTY, EXPRESSED OR
IMPLIED, AND ALL IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE HEREBY DISCLAIMED. This warranty does not apply to any products which have been damaged by lightning storms, water, or power surges or which have been neglected, altered, abused, used for a purpose other than the one for which they were manufactured, repaired by the customer or any party without MTS’s written authorization, or used in any manner inconsistent with MTS’s instructions.
MTS’s entire obligation under this warranty shall be limited (at
MTS’s option) to repair or replacement of any products which prove to be defective within the warranty period, or, at MTS’s option, issuance of a refund of the purchase price. Defective products must be returned by Customer to MTS’s factory transportation prepaid.
20
Chapter 3 - Service, Warranty and Tech Support
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL
DAMAGES AND UNDER NO CIRCUMSTANCES WILL ITS
LIABILITY EXCEED THE PURCHASE PRICE FOR
DEFECTIVE PRODUCTS.
Tech Support
Multi-Tech has an excellent staff of technical support personnel available to help you get the most out of your Multi-
Tech product. If you have any questions about the operation of this unit, call 1-800-972-2439. Please fill out the CC1600series modem rack information (below), and have it available when you call. If your CC1600-series modem rack requires service, the tech support specialist will guide you on how to send in your CC1600-series modem rack (refer to the Service section of this chapter).
Recording Rack Information
Please fill in the following information on your Multi-Tech
CC1600-series modem rack. This will help tech support in answering your questions. (The same information is requested on the Warranty Registration Card.)
Model No.:
Serial No.:
The model and serial numbers are on the bottom of your
CC1600-series modem rack.
Please note any diagnostic test results. Use the space below to note rack status:
_________________________________________________________________________________
_________________________________________________________________________________
_______________________________________________________________________________
________________________________________________________________________________________________________
___________________________________________________________________________________________________________________
21
CC1600-Series Owner's Manual
Service
If your tech support specialist decides that service is required, your rack may be sent (freight prepaid) to our factory. Return shipping charges will be paid by Multi-Tech Systems.
Include the following with your rack:
• a description of the problem.
• return billing and return shipping addresses.
• contact name and phone number.
• check or purchase order number for payment if the
CC1600-series modem rack is out of warranty. (Check with your technical support specialist for the standard repair charge for your CC1600-series modem rack).
• if possible, note the name of the technical support specialist with whom you spoke.
If you need to inquire about the status of the returned product, be prepared to provide the serial number of the product sent
(see Recording Rack Information on the previous page).
Send your rack to this address:
MULTI-TECH SYSTEMS, INC.
2205 WOODALE DRIVE
MOUNDS VIEW, MINNESOTA 55112
ATTN: SERVICE OR REPAIRS
You should also check with the supplier of your CC1600series modem rack on the availability of local service and/or loaner units in your area.
22
Chapter 3 - Service, Warranty and Tech Support
The Multi-Tech BBS
For customers who do not have Internet access, Multi-Tech maintains a bulletin board system (BBS) that mirrors its FTP site. Information available from the BBS includes new product information, product upgrade files, and problem-solving tips.
The phone number for the Multi-Tech BBS is (800) 392-2432
(USA and Canada) or (612) 785-3702 (international and local).
The BBS can be accessed by any asynchronous modem operating at 1200 bps to 33,600 bps at a setting of 8 bits, no parity, and 1 stop bit (8-N-1).
To log on to the Multi-Tech BBS
1.
Set your communications program to 8-N-1.
2.
Dial our BBS at (800) 392-2432 (USA and Canada) or
(612) 785-3702 (international and local).
3.
At the prompts, type your first name, last name, and password; then press ENTER. If you are a first time caller, the BBS asks if your name is spelled correctly. If you answer yes, a questionnaire appears. You must complete the questionnaire to use the BBS on your first call.
4.
Press ENTER until the Main Menu appears. From the
Main Menu you have access to two areas: the Files Menu and News. For help on menu commands, type ?.
To Download a file
If you know the file name
1.
From the Main Menu, type F to access the Files Menu, then type D.
2.
Enter the name of the file you wish to download from the
BBS.
3.
If a password is required, enter the password.
4.
Answer Y or N to the automatic logoff question.
23
CC1600-Series Owner's Manual
5.
Select a file transfer protocol by typing the indicated letter, such as Z for Zmodem (the recommended protocol).
6.
If you select Zmodem, the transfer will begin automatically.
If you select another protocol, you may have to initiate the transfer yourself. (In most datacomm programs, the PAGE
DOWN key initiates the download.)
7.
When the download is complete, press ENTER to return to the File Menu.
8.
To exit the BBS, type G and press ENTER.
If you don’t know the file name
1.
From the Main Menu, type F to access the Files Menu. For a list of file areas, type L, press ENTER, then type L and press ENTER again. (If you do not type the second L, you will list all of the files on the BBS.)
2.
Mark each file area you would like to examine by typing its list number and pressing ENTER.
3.
Enter L to list all the files in the selected file areas. Enter C to go forward in the file list and P to go back.
4.
To mark one or more files for download, type M, press
ENTER, type the list numbers of the files, and press
ENTER again.
5.
Enter D. You will see a list of the files you have marked.
Enter E if you would like to edit the list; otherwise enter D again to start the download process.
6.
Select a file transfer protocol by typing the indicated letter, such as Z for Zmodem (the recommended protocol).
7.
If you select Zmodem, the file will transfer automatically. If you select another protocol, you may have to initiate the transfer yourself. (In most data communications programs, the PAGE DOWN key initiates the download.)
8.
When the download is complete, press ENTER to return to the File Menu.
9.
To exit the BBS, type G and press ENTER.
24
Chapter 3 - Service, Warranty and Tech Support
About the Internet
Multi-Tech is a commercial provider on the Internet. If you prefer to receive service via the internet, you can contact Tech
Support via e-mail at the following address: http://www.multitech.com/_forms/email_tech_support.htm
Multi-Tech's presence includes a Web site at: http://www.multitech.com
and an ftp site at: ftp://ftp.multitech.com
About the Multi-Tech Fax-Back Service
Multi-Tech’s fax-back system provides 24-hour access to sales, marketing, and technical literature. Dial 612-717-5888, follow the voice prompts, and request document number 10 for a catalog of available documents. For convenence, have your fax number handy: _________________________. From the catalog of available documents, you can order newsletters, white papers, press releases, etc. from the sales and marketing index, or order basic modem operation and troubleshooting guides from the technical support and engineering index. Just enter the applicable FB Doc. # from the left column of the catalog.
25
CC1600-Series Owner's Manual
26
CC1600 -Series
Card Cages
Appendices
CC1600-Series Owner's Manual
Appendix A - Safety Requirements
1.
No manual adjustments to the equipment are necessary for connection to mains power within rated voltage and frequency.
2.
The power supply cord is intended to serve as the disconnect device. The socket-outlet must be installed near the equipment and be easily accessible.
3.
To reduce the risk of shock, all openings should be covered during normal operation of the equipment.
4.
Use only plugs and cordage for connection of the power supply to primary power which meets the safety and regulatory requirements in the country of use.
5.
Conductors must have a cross-sectional area of not less than 1.00 mm 2 .
Exigences de sécurité
1. Aucun réglage manuel de l'équipement n'est nécessaire pour des connexions à l'alimentation principale sous une tension et une fréquence nominales.
2. Le cordon d'alimentation a été conçu pour servir de dispositif de déconnexion. La prise d'alimentation doit être installée près de l'équipement et doit être facile d'accès.
3. Afin de réduire les risques de choc, toutes les ouvertures doivent être couvertes pendant le fonctionnement normal de l'équipement.
4. N'utiliser que des prises et cordons d'alimentation répondant aux normes de sécurité du pays de destination.
5. La superficie de la section des conducteurs doit être supérieure ou égale à 1,00 mm 2 .
28
Appendix A - Safety Requirements
Requisitos de seguridad
1.
No son necesarios ajustes manuales del equipo para la conexión a la corriente de la red dentro del voltaje y frecuencia establecidas.
2.
El conector de alimentación de energía sirve como dispositivo de desconexión. La toma de corriente se debe instalar cerca del equipo y tener un acceso sencillo.
3.
Para reducir el riesgo de sacudida eléctrica, todas las aberturas deben estar cubiertas durante el manejo normal del equipo.
4.
Utilice solamente los enchufes y cables para la conexión del suministro de energiá a la energiá primaria que cumplan con los requerimientos regulativos y de seguridad del país en que se usen.
5.
Los conductores deben tener un área transversal mayor de 1,00 mm 2 .
Sicherheitsanforderungen
1.
Bei Anschluß am Versorgungsnetz innerhalb der
Nennleistung und -frequenz ist es nicht erforderlich, dieses Gerät manuell nachzustellen.
2.
Die Netzschnur dient als Trennvorrichtung. Die Steckdose muß in der Nähe des Geräts installiert werden, um leicht zugänglich zu sein.
3.
Um Elektroschockgefahr zu vermindern, müssen beim normalen Betrieb des Geräts alle Öffnungen abgedeckt sein.
4.
Zum Anschluß an das Primärstromnetz nur Stecker und
Anschlußkabeln benutzen, die den Sicherheits- und
Überwachungsvorschriften des Landes entsprechen, in dem sie angewendet werden.
5.
Leitungsdrähte müssen einen Durchmesser von mindestens 1,00 mm 2 haben.
29
CC1600-Series Owner's Manual
Mains Wiring Instructions (U.K.)
When wiring the mains plug, the following instructions must be followed:
• the core which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol , or coloured green and yellow.
• the core which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
• the core which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red.
Power Requirements
AC 90-245V, 50/60 Hz, 2.0A
DC 40-56V, 2.5A
CAUTION: Safety requirements are not fulfilled unless the equipment is connected to a wall outlet socket that is provided with an earth contact.
Alimentation Requise
C.A. 90-245 V, 50/60 Hz, 2.0A
DC 40-56V, 2.5A
ATTENTION: Les conditions de sécurité ne sont pas remplies si votre équipement n'est pas branché sur une prise murale avec mise à la terre.
30
Appendix A - Safety Requirements
Requisitos de potencia
C.A. 90-245 V, 50/60 Hz, 2.0 Amp
DC 40-56V, 2.5A
ATTENCION: Adviertase que los requisitos respecto a medidas de seguridad no quedan satisfechos a menos que este equipo eléctrico esté conectado a una toma de corriente mural conectada a tierra.
Stromaufnahme
AC 90-245V, 50/60 Hz, 2.0A
DC 40-56V, 2.5A
VORSICHT: Die Sicherheitsvorschriften sind nur erfüllt, wenn das Gerät an eine geerdete Wandsteckdose angeschlossen ist.
31
CC1600-Series Owner's Manual
Appendix B - Cabling
Introduction
This appendix shows the cable and connector pinouts for the CC1600 rack.
Dial/Leased Splitter
The Dial/Leased Splitter consists of an RJ11 plug at one end of a 5-inch cable that plugs into the RJ11 jack on the backplane of the CC1600 rack. The other end of the cable has two RJ11 jacks that connect to a leased line and, if dial back-up is used, the Dial jack provides that connection.
RJ11 Plug
RJ11 Jacks
LEASED
DIAL
6
5
4
3
2
1
RJ11
PLUG
RJ11
JACK
6
5
4
3
2
1
LEASED
6
5
4
3
2
1
RJ11
JACK
DIAL
32
Appendix A - Safety Requirements
-21 Series Connector Pinouts
Three 50-pin connectors are used on the -21 series rack; they are located at the top of the backplane. The Dial-up/2-
Wire Leased connector is to the left (as viewed from behind the chassis), the 4-wire Receive connector is in the center, and the 2-Wire Leased/4-Wire Transmit connector is on the right side of the backplane. Pinouts for each connector are shown below.
DIAL UP / 2 WIRE
LEASED
CONNECTOR
RING1 26
RING2 27
RING3 28
RING4 29
RING5 30
RING6 31
RING7 32
RING8 33
RING9 34
RING10 35
RING11 36
RING12 37
RING13 38
RING14 39
RING15 40
RING16 41
42
43
44
45
46
47
48
49
50
J17
4 WIRE
RECEIVE
CONNECTOR
4W R RING1 26
4W R RING2 27
4W R RING3 28
4W R RING4 29
4W R RING5 30
4W R RING6 31
4W R RING7 32
4W R RING8 33
4W R RING9 34
4W R RING10 35
4W R RING11 36
4W R RING12 37
4W R RING13 38
4W R RING14 39
4W R RING15 40
4W R RING16 41
42
43
44
45
46
47
48
49
50
J17
1 4W R TIP1
2 4W R TIP2
3 4W R TIP3
4 4W R TIP4
5 4W R TIP5
6 4W R TIP6
7 4W R TIP7
8 4W R TIP8
9 4W R TIP9
10 4W R TIP10
11 4W R TIP11
12 4W R TIP12
13 4W R TIP13
14 4W R TIP14
15 4W R TIP15
16 4W R TIP16
17
18
19
20
21
22
23
24
25
2 WIRE LEASED /
4 WIRE TRANSMIT
CONNECTOR
4W X RING1 26
4W X RING3 28
4W X RING4 29
4W X RING5 30
4W X RING6 31
4W X RING7 32
4W X RING8 33
4W X RING9 34
4W X RING10 35
4W X RING11 36
4W X RING12 37
4W X RING13 38
4W X RING14 39
4W X RING15 40
4W X RING16 41
42
43
44
45
46
47
48
49
50
J17
1 4W X TIP1
2 4W X TIP2
3 4W X TIP3
4 4W X TIP4
5 4W X TIP5
6 4W X TIP6
7 4W X TIP7
8 4W X TIP8
9 4W X TIP9
10 4W X TIP10
11 4W X TIP11
12 4W X TIP12
13 4W X TIP13
23
24
25
19
20
21
22
14 4W X TIP14
15 4W X TIP15
16 4W X TIP16
17
18
33