advertisement
Sample Unit
Generator Ratings* @ 1800 RPM
Voltage Ph Hz
120/240 1 60
120/208 3 60
120/240 3 60
277/480 3 60
Standby Output
kW (kVA)
150 (150)
150 (188)
150 (188)
150 (188)
Standard Generator Set Features
Prime Output kW (kVA)
135 (135)
135 (169)
135 (169)
135 (169)
Standby Max Amp
Output
625
520
451
226
Optional Equipment
Number of
Wires
12
12
12
12
· Perkins Diesel Engine Model 1106D-E66TAG3 Tier 3
· AC, Single bearing direct coupled alternator with class
‘H’ insulation, sized for 130°C temperature rise.
· Engine and alternator mounted on vibration isolators.
· Radiator sized for 120°F ambient clearance
· High coolant temp., low oil pressure safety shutdowns.
· Dry type air cleaner.
· 12-VDC starter, engine mounted battery charging alternator, battery cables and rack along with grounding strap.
· Microprocessor based control panel w/ metering, alarms,
shut down, under / over frequency & voltage protection.
· Weather protective enclosure constructed of marine grade aluminum 0.125 thickness, SS hardware
White powder coat paint finish on both sides
Sound insulation resistant to high temperatures,
fuel and oil. Hinged, removable keyed alike doors.
Residential rated interior mounted exhaust silencer
Vertical radiator and exhaust discharge
Oil & coolant drain lines with brass ball check valves
· Mainline circuit breaker.
· Digital or analog control panels.
· Automatic transfer switch
· Starting battery
· Automatic battery chargers 6 or 10 amps
· Thermostat controlled jacket water heater
· Low coolant level switch
· Single wall tanks
· UL 142 fuel tanks
· Day tanks
· Water separator fuel filter
· Space heater
· Permanent Magnet Generator (PMG) with voltage
regulator upgrade
· Generator drip covers
· 17 Light remote annunciator panel
· 120V Receptacle for battery charger and / or coolant
heater.
· D.O.T trailers, single or dual axle with brakes.
· Enviro - friendly custom color options.
*Stand by ratings are applicable for the duration of any power outage. No overload is available at these ratings. Prime ratings are continuous per BS 5514, DIN 6271,
ISO3046 & IEC 34-1. Overload capacity on prime-power ratings is 10% for one hour in each twelve hours of operation. All single phase ratings are based on a 1.0 power factor, three (3) phase ratings based on a 0.8 power factor. Ratings are established based on 85°F ( 29°C ) and an elevation of 1,000 feet ( 305 meters ).
Please consult your Stateline representative for information concerning derates for temperature, altitude & humidity.
Model: Perkins 1106D-E66TAG3 Tier 3
Max power: 220 bhp / 164 kWm @ 1800 rpm
Cubic capacity: 402.8 in³ / 6.6 L
Bore & stroke: 4.13” x 5” (105mm x 127mm)
Turbocharged, air to air charge cooled, 6 cylinder in line
direct injected, governor type-electronic ± 0.4%
Frequency regulation: Isochronous, steady-state ± 0.25%
Flywheel to SAE J620 size 11.5 / housing SAE 3
Fluids: Oil cap. total system - 17.4 quarts ( 16.5 liters )
Coolant cap. w/ radiator - 5.5 gallons ( 21 liters )
Engine Specifications
Fuel Consumption US gallon ( liters ) / hr @ 1800 rpm
50% load - 6.08 ( 23 )
75% load - 8.45 ( 32 )
100% load - 10.5 ( 40 )
General: Oil filter-Spin-on type glow plugs
Electrical system: 12v starter, 100amp alternator DC output
Minimum recommended battery size: 1190 CCA
Fuel type: BS 2869: Part 2 1998 Class A2 or BS EN590 or JP8
Alternator Specifications
Marathon Electric: Type brushless, 4pole rotating field
Voltage regulation: + / - 1%, volts/hertz, electronic, EMI filtered
Class insulation: ‘H’ to NEMA MG-1-1.66
Rated temperature: Standby 130 C° rise / 40 C° ambient
Coupling: SAE adapter, flexible disc, direct.
Load acceptance: One step, 100% per NFPA 110
Features: Self ventilated drip-proof construction. Superior voltage
waveform achieved by a 2/3 pitch and skewed rotor.
Vacuum-impregnated windings with fungus-resistant epoxy for
dependability and long-life. Compliance with NEMA, IEEE and ANSI
standards for temp. rise. Sustained short-circuit capability enabling
down-line circuit breakers to trip without collapsing the generator field.
No load to full-load regulation of +/- 2%.
DGC2020
Microprocessor based, navigation key with large LCD display event recording transfer switch control SAE J1939 CANBUS communication multilingual capability suitable for rental application.
Remote communication capability (optional)
Control Panel Specifications
·
Operational features
Alternator protection: under / over voltage,
under / over frequency.
·
Engine protection: Low oil pressure, high
coolant temperature, over speed & over
crank, sender unit failure, fuel leak / fuel
sender failure, battery charger failure.
·
All protections are programmable as alarms or pre-alarms.
·
Operating power: Nominal 12-24 Vdc
consumption 14.2W run mode
•Metering (ample range): Volts, current, Hz
watts, VA, Pf oil pressure, coolant
temperature, rpm, DC volts, fuel level,
engine running time.
• Engine vontrol with timers
• External remote start input (on or off load)
• 16 programmable contact inputs.
• 7 Contact outputs
Agency Approvals: UL 508 R CSA C22.2 No 14 NFPA 110
CE Compliance: EC LVD-73/23/EEC EN 61000-6-4:2001 EMC EN 50178:1997 EMC- 89/336/EEC EN 610000 6-2:2001 EMC Immunity
One complete set Owners / Operators, Engine, Alternator and Accessory manual
Dimensional and Mounting Specifications
inches (mm): 131.50 ( 3340 ) L x 44 ( 1118 ) W x 67 ( 1702 )H (Enclosure only)
Estimated Dry Weight lb. (kg): 3820 (1732) Less Fuel Tank
Note: The above dimensions and weights would change if a sub-base fuel tank was added. An electrical stub area is positioned at the rear of the sub-base fuel tanks. Spacing from rear access cover to the tank is approximately 9 inches (228.6 mm).
Specifications subject to change without notice
15749 Lyons Valley Rd.
Jamul CA 91935 www.HardyDiesel.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement