Hillandale Range

Installation & Operating

Instructions

Covering Model(s):

Hercules 12, 20 & 30 Multifuel Boiler Stoves

Open Vented Only

Tested to EN 13240

These appliances must be installed and commissioned by a HETAS registered engineer

JUL13GB Issue 2 1

Contents

Packing List

Health & Safety

3

4

Specifications 5

Dimensions 6

Assembly

Example Layout

Stove Operation

11

Warning Notes

Maintenance

Ash Removal

Chimney Fires

Glass Cleaning

Commissioning Form

Spare Parts

EC Declaration

Warranty

JUL13GB Issue 2

22

23

23

23

25

26

27

29

2

Introduction

May we take this opportunity to thank you for choosing one of our cast iron, multifuel stoves.

The term multifuel refers to the fact that the appliance is capable of burning either wood logs or coal (that is suitable for closed appliances). Both of these fuels have very different air requirements in order for them to burn correctly, therefore the air controls need to be operated differently depending on the fuel being burned (see section “Stove Operation”).

See the section “Lighting the Stove” for further details. After reading this document, if there is anything you are unsure about, please contact your dealer or our Technical Support

Department.

These instructions cover the basic principles to ensure the satisfactory installation of the stove, although detail may need slight modification to suit particular local site conditions. In all cases the installation must comply with current Building Regulations, Local Authority

Byelaws and other specifications or regulations as they affect the installation of the stove.

It should be noted that the Building Regulations requirements may be met by adopting the relevant recommendations given in British Standards BS 8303 and BS EN 15287-1 2007 +

A1 2010 as an alternative means to achieve an equivalent level of performance to that obtained following the guidance given in Approved Document J.

Please note that it is a requirement under the Broseley Fires warranty system that the installation of the stove is carried out by a Competent Person registered with a

Government approved Competent Persons Scheme. HETAS Ltd operate such a

Scheme and a listing of their Registered Competent Persons can be found on their website at www.hetas.co.uk

.

Packing List

1x Cast-iron stove

1x Ash Tool (poker)

1x Instruction booklet

1x Heat Proof Gloves Set

2x Cast iron Grates

2x Steel Ash pans

1x Steel Baffle

3x Log Retainer Bars

All parts will be inside the main stove body upon delivery.

JUL13GB Issue 2 3

Health & Safety

Special care must be taken when installing the stove such that the requirements of the

Health and Safety at Work Act are met.

Installation

This appliance MUST be installed and commissioned by a HETAS registered installer in

England and Wales and a fully qualified Heating Engineer in Scotland and Ireland.

Handling

Adequate facilities must be available for loading, unloading and site handling.

Fire Cement

Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of contact wash immediately with plenty of water.

Asbestos

This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective equipment.

Metal Parts

When installing or servicing this stove care should be taken to avoid the possibility of personal injury.

CO Alarms

Building regulations require that whenever a new or replacement fixed solid fuel or wood/biomass appliance is installed in a dwelling an audible carbon monoxide alarm must be fitted in the same room as the appliance. Further guidance on the installation of the carbon monoxide alarm is available in BS EN 50292:2002 and from the alarm manufacturer’s instructions. Provision of an alarm must not be considered a substitute for either installing the appliance correctly or ensuring regular servicing and maintenance of the appliance and chimney system.

Fire Guards

When using the stove in situations where children, aged and/or infirm persons are present a fireguard must be used to prevent accidental contact with the stove. The fireguard should be manufactured in accordance with BS 6539.

Aerosol Sprays

Do not use an aerosol spray on or near the stove when it is alight.

Operating Tool & Gloves

Always use the operating tool and glove provided when handling parts likely to be hot when the stove is in use.

JUL13GB Issue 2 4

Specifications

In the UK these stoves have been tested and approved to EN13240 as an intermittent heating appliance for burning manufactured or naturally occurring smokeless coal and wood logs only.

12B 20B 30B

Maximum heat output to room (kW)

Maximum heat output to water (kW)

Flue diameter MINIMUM*

Efficiency %

Temperature exhaust gas – wood (ºC)

Optimal working temperature

Boiler capacity (litres)

Flow & return pipe fitting (female)

Flue draft Pressure

(tested when hot) WOOD (mbar/PA)

Maximum working temperature

Maximum allowable water pressure (bar)

Stove depth (mm)

Stove Height (mm)

Stove Width (mm)

Stove Weight (Kg)

4

8

6

14

8

22

7 Inch (178mm) 7 Inch (178mm) 7 Inch (178mm)

73 75.4

75.4

190

70º - 75º

18

1.5” BSP

190

70º - 75º

20

1.5” BSP

190

70º - 75º

22

1.5” BSP

0.17 – 2

17/2.0

94º - 95º

1.5

440

768

747

201

0.17 – 2

17/2.0

94º - 95º

1.5

510

768

747

225

0.17 – 2

17/2.0

94º - 95º

1.5

620

768

747

252

European standards need to be complied with when installing this appliance.

JUL13GB Issue 2 5

Dimensions

JUL13GB Issue 2

All dimensions are in millimetes

6

Hearth Requirements & Clearances

These appliances WILL require a full constructional hearth as laid out in building

regulations approved document J.

Your stove must be installed on a solid, level non-combustible hearth. The hearth protrusion in front of the stove to carpets or wooden floors must be at least 300mm. As it is possible, that on opening the door of the stove for fuel to fall out, a fender must be fitted if the hearth is flush with the carpet. These are just a few hearth specifications. Please refer to Building Regulations Approved Document J (Hearths) for more specific details.

Clearances

The stove requires the following clearances around it to ensure the heat is released into the room and to allow sufficient combustion air flow. A combustible material clearance is given to prevent damage to any items that may be affected by heat.

Stove

Clearances

A B C Above

Non-Combustible 100mm 100mm 300mm 200mm

JUL13GB Issue 2 7

Chimney Requirements

This appliance must not be fitted into a chimney serving another heating appliance. It is most important that there is no obstruction in the flue or chimney. Please ensure that any existing chimney is clear of obstruction and swept clean immediately before installation of the new stove. If the chimney has been used for an open fire it is recommended that it be swept for a second time having been used for a month following installation.

A flue draught minimum of 10 Pascals to a maximum 14 Pascals is required for satisfactory appliance performance. A properly built masonry or factory constructed chimney (with a minimum vertical height of 5 metres) should ensure a consistent draught

(draw). 45° bends can be used in the flue run (maximum of four bends) you will need to add an extra 1 metre of vertical flue height for each bend.

The flue draught should be checked under fire at high output and if it exceeds the recommended maximum, a draught stabiliser must be fitted so that the rate of burning can be controlled, and to prevent over firing (See section “Warning Notes”). If you have any doubts about the suitability of your chimney, consult your local dealer/stockist or engineer.

If your flue draft is below the minimum recommendation then it may be neccesary to increase the vertical chimney height, add additional flue insulation or possibly add a special cowl to the top of the chimney (e.g. anti down draft cowl to eliminate wind induced down draft).

The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J.

If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house. Older properties, especially, may have chimney faults or the cross section may be too large i.e. more than 230 mm x 230 mm.

Remedial action should be taken, if required, seeking expert advice, if necessary. If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Approved Document J.

If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used. These chimneys must be fitted in accordance with the manufacturer’s instructions and Building Regulations.

If a flexible liner is required the liner diameter must not be less than 6”.

Any bend in the chimney or connecting fluepipe should not exceed 45°. 90° bends are not permitted. . For top flue installations it is possible to sweep through the appliance by removing the internal baffle however it is recommended that you provide adequate access

(e.g. easily accessible soot door).

JUL13GB Issue 2 8

Chimney Requirements

JUL13GB Issue 2 9

Combustion Air Requirements

In order for the stove to perform efficiently and safely there should be an adequate air supply into the room in which the stove is installed to provide combustion air. This is particularly necessary in modern houses where drafts have been almost eliminated by double glazing etc.

Under UK building regulations any appliance over 5kW MUST have a fixed permanent air vent. The requirement calls for 550mm

2 of free ventilation per kW above the 5kW threshold, which means that the 30B (as an example) will require a fixed permanent air vent that provides 25 x 550mm

2

of combustion air.

There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room.

(see building regulations approved document J for further information).

JUL13GB Issue 2 10

Assembly

The diagram below shows the main components of the stove and how it can be broken down for transport purposes.

JUL13GB Issue 2 11

Plumbing Advice

Boiler installations should only be carried out by qualified heating engineers who hold a HETAS wet systems certificate or equivalent. A site survey prior to commencing installation is highly recommended to identify any potential problem

areas.

The stove is fitted with four 1.5” female pipe connections as shown below. It is important to note that the boiler on this appliance is one singular open vessel so it is perfectly possible to only use two connections (and cap the others off).

The top connections are the flow and bottom connections return. It is good practice to use diagonal opposites to promote good flow around the boiler e.g. top left flow and bottom right return.

Please note this appliance is not suitable for “DIY” installation therefore only general guidance is given in this section as your installer will already be familiar with open vented boiler installation (including best plumbing practices and building

regulations).

JUL13GB Issue 2 12

Plumbing Advice

Open Vented Plumbing

It is critical that this appliance is only connected to open vented systems, which must include a gravity circuit with an expansion tank open to the atmosphere.

When installing this appliance on a gravity circuit, the system should consist of a tank/indirect cylinder fixed in an upright position and should be connected to the boiler by

28mm pipe (both flow and return). The pipes should not exceed 7.8m in length. The shorter the run of pipe work the more effective the appliance is going to be at heating the water. The cylinder and pipe work should be lagged to minimise the heat loss in the system.

A ‘heat-leak’ radiator must be incorporated into the system to dissipate any excess heat produced from the boiler when connected demands are low. The heat leak radiator must be sized at a minimum of 10% the boiler output. Fit the heat leak radiator in the gravity circuit using 22mm pipe reducing to 15mm for no more than 300mm before the radiator.

Commission/Handover

Ensure loose parts are fitted in accordance with the instructions for “Assembly” given previously. On completion of the installation, allow a suitable period of time for any fire cement and mortar to dry out; a small fire may then be lit and checked to ensure the smoke and fumes are taken from the stove up the chimney and emitted safely outdoors.

Do not run at full output for at least 24 hours.

On completion of the installation and commissioning, ensure that this installation and operation manual for the stove is left with the customer. Ensure the customer is advised on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove.

Advise the user what they should do if smoke or fumes be emitted from the stove. The customer should be warned to use a fireguard to BS 6539 in the presence of children, aged and/or infirm persons. Advise the user not to fit an extractor fan in the same room as the stove as this can cause the stove to emit fumes into the room.

Example Plumbing Layouts

The following pages give examples of typical system layouts, it is important to note these diagrams are for illustration purposes only as each property will differ and individual layouts will need to be designed by qualified professionals.

JUL13GB Issue 2 13

Example Four Pipe Plumbing Layout

JUL13GB Issue 2 14

Example Three Pipe Plumbing Layout

JUL13GB Issue 2 15

Example Two Pipe Plumbing Layout

JUL13GB Issue 2 16

Controls Layout

The stove is fitted with a number of controls which need to be correctly operated in order to light and maintain a fire.

JUL13GB Issue 2 17

Controls Explained

Primary Air Intakes

The primary air intakes are located at the bottom of each door, they are in the form of spinners. Having the spinners turned fully anti-clockwise indicates the intake is fully open

(and fully clockwise means it is fully closed). This particular air intake is adjustable throughout its travel to control the total amount of air entering below the grate for combustion.

The primary air intake is used on initial firing of the stove or when burning coal etc. Please see the BURNING COAL for a more in depth description.

Secondary Air Intake

The secondary air intake is the spinner located above the doors, as with the primary intake fully anti-clockwise is fully open and fully clockwise is fully closed. Air entering through this control is pushed down the inside of the glass creating the Airwash System – see below.

This particular design also allows the air to be released on top of the grate which is ideal when burning wood products. Please see section BURNING WOOD.

Tertiary Air Intake

The tertiary air intake is a flap located on the right hand side of the stove, This control allows air to enter at a higher point inside the burn chamber and will provide an extra boost of heat. This control can be used at initial start-up and when an additional boost of heat is required.

Airwash System

Airwash is a system where secondary air is drawn down the inside of the glass by combustion. The flow of air helps prevent the smoke coming into contact with the glass. It does not mean that you will never have to clean the glass, but substantially lengthens the periods between cleaning. The air-wash system works best when burning dry wood as wet wood will produce more deposits on the glass. Also, deposits will form on the back of the glass when the stove is operated on low heat for extended periods (where fuel is only just smouldering).

JUL13GB Issue 2 18

Recommended Fuels

This appliance has obtained CE EN13240 approval for burning –

* HETAS approved coal suitable for a closed appliance.

* Split Wood logs not exceeding 35cms in length and not over 20% moisture content.

Approval does not cover the use of other fuels either alone or mixed with the suitable fuels listed above.

Although approval covers the use of the smokeless fuels listed, the claimed rated output, has been obtained burning a single representative smokeless fuel, under standard test conditions. However, in the home, a variety of operating conditions can occur and the performance of the appliance may vary to some degree with these conditions and different fuels may need to be burnt at different rates to provide the same heat output.

The recommended fuels are Wood logs no longer than 35cms (dry, seasoned to under

20% moisture) and solid mineral fuels (e.g. Natural smokeless fuels) Larger coal briquettes are recommended as they concentrate less heat in one spot reducing the likelihood of damage to the grate. Ask your local fuel merchant or consult the HETAS website for more details on these fuels.

Only authorised smokeless fuels may be used in smoke control areas.

Do NOT burn “Housecoal” or any other coal which are intended for use on open

fires. Suitable coal needs to be designed for use on closed appliances. Open fires send a large amount of heat up the chimney therefore the fuel needs to burn extremely hot in order to send heat into the room, closed appliances are highly efficient and send little heat up the chimney therefore the fuel does not need to burn as hot. Using open fire coal on a closed appliance will cause excessive wear on the stove and could result in damage which will not be covered by the products warranty.

Under NO circumstances burn “petroleum coke” or any other chemically enhanced fuel as it will burn out the internal grate and baffle plates in a very short period of time and may damage the stove beyond repair.

Do NOT burn wet wood, This will give a poor heat output and will cause heavy deposits of soot and tar to accumulate on the glass and throughout the stove and flue. Tar and soot build-ups will also insulate the boiler causing poor heat transfer to the water, the coating of soot and tar in the chimney is volatile creating a high risk of chimney fires. A growing tree contains a high percentage of water, the wood needs to be dried out (seasoned) before it is suitable for burning (this can take several years). Wood logs are best stored in a stack, sheltered from the weather, in a well ventilated area and raised off the ground. This allows the air to circulate and prevents mildew.

JUL13GB Issue 2 19

Lighting the Stove

Curing

On initial firing you will notice a very pungent odour, this is caused through the curing of the paint, we recommend starting with short burning sessions (with smaller quantities of fuel) and build up gradually to allow the components of the stove to settle. Opening doors and windows will allow the paint curing odour to dissipate and to allow ventilation into the room. Curing times can vary but typically should take around 8-12 hours (operation at high output) to complete.

Kindling

Stage1

Ensure the Primary and Secondary air spinner are fully open (anti-clockwise). The Tertiary air intake flap should be closed at this point. With both doors open, start your fire using twists of newspaper (or scrunched up balls) to form a bed on the grates. Place a generous amount of dry kindling onto the newspaper, ensure their is sufficient air gaps between the kindling (a criss cross or pyramid style pattern is ideal to accomplish this).

Kindling ---------------

Newspaper -----------

Stage 2

Ignite the paper underneath using a match or suitable fire-lighter. Allow the paper and kindling to burn until it reduces down into hot embers. If the fire is dying during this stage the door can be closed but not latched leaving a small gap for extra combustion air.

Stage 3

Add another generous load of dry kindling and allow to burn down.

It may be necessary to repeat this stage if the chimney is cold or if you find you have smoke entering the room. This stage is vital for getting heat into the chimney which will create the draw that takes the smoke away, we would expect this stage to take between

15-20 minutes.

It is critical that you do not leave the stove during the entire lighting and kindling

stage. See Burning wood and Burning Coal sections for the next steps.

JUL13GB Issue 2 20

Burning Wood

With kindling complete you are now ready to add your wood logs.

Stage 4

Place 3-5 small logs onto the bed of hot embers using the gloves provided, close the door and reduce the primary air intakes (turn spinners clockwise) to approximately half way. Once the logs turn black the primary air intakes can be fully closed.

Stage 5

Once the smaller logs have burned down you can now add 2-3 larger (or full size) logs and close down the Secondary Air Intake as required. You can now control the burn rate of the stove using the secondary air intake, you are looking for a controlled flame (not smouldering in the embers or licking around the lid) this is mostly visual although a flue pipe thermometer will help you determine correct control and is recommended for the initial lightings.

Stage 6

Refuel as and when required (take care to open the door gradually as flames may lick out). Open the primary air spinners whenever refuelling , once the wood logs turn black the primary air spinners can be fully closed again and the fire controlled as before using the secondary air spinner.

For an extra boost of heat you can now open the Tertiary air flap. If you no longer want to keep the fire going simply allow it to burn out.

Burning Coal

With kindling complete you are now ready to add your approved coal.

Stage 4

Using the gloves and provided ash tool, rake the hot embers evenly over the grates and add a small amount of coal. Close the doors and allow the coal to ignite then close the Secondary Air spinner approximately half way. The primary air spinners should be left fully open.

Stage 5

When the small load of coal has burned down add a larger load and allow time for the coal to fully ignite. You can now close the Secondary air spinner fully. You will now control the burn rate of the stove using the primary air spinners, you are looking for a controlled flame (not smouldering in the embers or licking around the lid) this is mostly visual although a flue pipe thermometer will help you determine correct control and is recommended for the initial lightings.

Stage 6

Add coal as and when required, taking care to open the door gradually as flames may lick out.

Ensure that you use the ash tool and gloves when refuelling to poke through any ash and debris into the ash pans underneath, this is critical as coal requires a flow of air from underneath the grate. For an extra boost of heat you can now open the tertiary air flap. If you no longer want to keep the fire going simply allow it to burn out.

Only ever burn coal that is suitable for a closed appliance.

JUL13GB Issue 2 21

Warning Notes

Over-Firing

It is extremely important that you do NOT leave all of the air controls in the fully open position for extended periods or run the appliance with the door open. Leaving the air controls fully open (or running with the doors open) will lead to “over-firing”. Over-firing is caused when too much heat is generated within the fire chamber, this will lead to warping, buckling and general damage to the stove and its internal components. Over-firing can also be caused by an excessive flue draft.

PLEASE NOTE ANY DAMAGE TO THE APPLIANCE CAUSED THROUGH OVER-

FIRING WILL NOT BE COVERED BY THE WARRANTY.

We highly recommenced the use of a flue pipe thermometer so that you can monitor how much heat you are sending up the chimney, this will both enable efficient operation of your stove and also give a good indiction if you are over-firing the appliance.

Fumes

Properly installed, operated and maintained, this appliance will not emit fumes into the dwelling. Occasional fumes may occur whilst de-ashing and re-fuelling. However, persistent fume emission is potentially dangerous and must not be tolerated. If fume emission does persist, the following immediate actions should be taken:- a) b) c) d)

Open doors and windows to ventilate the room

Let the fire go out or eject and safely dispose of fuel from the appliance

Check for flue or chimney blockage and clean if required

Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. If necessary seek expert advice

JUL13GB Issue 2 22

Maintainance

Ash Removal

The ash pans can be removed by using the ash tool to hook it forward so that you can grasp the pan using the gloves provided. We would recommend emptying the ash into a metal bucket for transportation.

You should only empty the ash when the appliance and ashes are completely cool and can be disposed of in your normal household refuse.

Cleaning the Stove

We recommend only doing this when the stove is cold using a soft brush to clean any of the stove surfaces, this is normally sufficient to remove dust, ash and debris. For stubborn marks you can use a damp lint free cloth, ensure that all surfaces are dried off immediatley. We do not recommend using any kind of chemicals or abrasive materials. It is possible to touch up the paint using the original metallic black stove paint, however this new paint will then need to cure.

Glass Cleaning

A damp lint free cloth is normally sufficient, however for stubborn build ups we would recommend using a very fine wire wool.

Chimney Sweeping

It is essential that your chimney (flue) is swept at least once a year by a registered professional chimney sweep. Sweeping removes particles that could otherwise fuel a chimney fire, it should also highlight any potential issues such as leaks and damage to the flue.

Chimney Fires

In the event of a chimney fire ensure both Primary and Secondary air controls are fully closed and the door(s) remain closed at all times. If the chimney fire does not go out or if there is a serious risk to people and property, call the fire brigade immediately.

Regular sweeping of the chimney will remove combustible particles and will reduce the risk of chimney fires.

Stove Servicing

Your stove should be inspected anually to ensure all seals are present and correct and to gauge the condition of the internal components. The service should be done by a HETAS registered engineer who also perform a spillage test and acertain the correct functioning of the plumbing circuit.

JUL13GB Issue 2 23

Trouble-shooting

Smoke comes out of the stove when the loading door is opened.

• The chimney cavity into which the 150mm flue pipe has been installed may be less than the minimum requirement.

• Deposits (soot or other obstructions) may have built up in the chimney and be restricting the flow of waste products. This flow rate is known as the ‘draw’.

• Insufficient draw, this is especially common during milder weather. You will need to prolong the kindling stage to ensure the chimney (flue) is completely hot (you may even need to pre-heat the chimney using a method advised by the installer)

• Combustion air intake is not large enough or another appliance (eg. Extractor fan) is taking air away from the stove.

The Stove does not produce the expected heat into the room.

• Has the flue pipe been sealed to the chimney to prevent heat being drawn up the chimney to waste?

• Green or wet wood is being burnt.

• The chimney has excessive draw (this is unusual). Seek installer advice with regard to installing a Flue Draught Stabiliser.

• The stove has been recessed into the existing fireplace and a lot of heat is being absorbed by the surrounding fireplace walls rather than being radiated into the room. Pull the stove forward.

• For the maximum efficiency of heat transference into the room the stove should be sited on the hearth of the fireplace rather than recessed.

The Stove burns too fast.

• Use whole logs rather than split ones.

• The wood being used may be generally too small.

• The “air-tight” seal between the fibre rope on the doors and the casting may have been lost, adjust door handle lock nuts to reinstate this seal or replace.

• The chimney has excessive draw (seek installers advice on this point).

• The fibre rope seal between the door and the glass may be leaking. Tighten or replace.

• The fibre rope on doors and glass has worn out. Replace.

JUL13GB Issue 2 24

Commissioning Form

Commissioning Statement and Check-list

Stove Purchased From:_____________________________________________________

Address:_________________________________________________________________

Telephone Inc area code:____________________________________________________

Installation Date:_____/_____/__________ Stove Name:_________________________

Product Serial Number:________________ Invoice Number:_______________________

Stove installed by:_________________________________________________________

Address:_________________________________________________________________

Telephone Inc area code:____________________________________________________

HETAS Registration Number:________________________________________________

Check-list

Is the flue system the correct length and diameter for stove: Yes No

Stove controls fully explained to end user: Yes

Correct fuels explained to end customer: Yes

Alarm tested: Yes

No

No

Instruction booklet & HETAS certificate handed to end user: Yes No

Signature:__________________________ Print Name:___________________________

JUL13GB Issue 2 25

Spare Parts

(1) Base Casting (2) Legs (3) Boiler Section (4) Tertiary Air Tube (6) Baffle

(7) Ash Pans (9) Grate Set (10) Left Door (11) Right Door (14) Lid

(15) Reducer Ring (17) Front Casting (21) Log Retainers

JUL13GB Issue 2 26

EC Declaration

DECLARATION OF CONFORMITY

ACCORDING TO DIRECTIVES 89/106/EEC (CONSTRUCTION

PRODUCTS)

ISSUED BY:

TYPE OF EQUIPMENT:

TRADEMARK:

MODEL:

USE:

MANUFACTURER:

NOTIFIED BODY:

RRF 1625

BROSELEY FIRES LTD

KNIGHTS WAY, BATTLEFIELD ENT PARK.

SHREWSBURY. SY1 3AB ph: +44 (0)1743 461444

MULTI FUEL BOILER STOVE

BROSELEY FIRES LTD

HERCULES 12B 20B & 30B

DOMESTIC SPACE AND HOT WATER HEATING

BROSELEY FIRES LTD

KNIGHTS WAY, BATTLEFIELD ENT PARK.

SHREWSBURY. SY1 3AB ph: +44 (0)1743 461444

RRF Rhein-Ruhr Feuerstätten Prüfstelle GmbH

Firmensitz

Im Lipperfeld 34 b

D-46047 Oberhausen

The following harmonised standards and Technical specifications have been met and comply

with good engineering practice and safety matters in force within the EEC

All CE standards or other documents

Initial Type Test Reports 12B 40-07-1385

20B 40-07-1573

30B 40-07-1399

EN 13240 CE MARKING INFORMATION - See Instructions

As the Manufacturer's authorised representative established within the EEC, Broseley Fires Ltd

Declare sole responsibility that the product for mentioned follows the provisions of the directives

above.

13/11/2013 Shrewsbury UK

Place and date of issue

STEPHEN GOODWIN

Head of Research & Development

JUL13GB Issue 2 27

Annual Service Record

1ST SERVICE

COMPANY NAME: .

CONTACT NUMBER

2ND SERVICE

COMPANY NAME:

POSTCODE:

. No.

.

POSTCODE:

3RD SERVICE

COMPANY NAME: .

POSTCODE:

4TH SERVICE

COMPANY NAME:

5TH SERVICE

.

POSTCODE:

COMPANY NAME:

6TH SERVICE

COMPANY NAME: .

.

POSTCODE:

POSTCODE:

JUL13GB Issue 2 28

Warranty

This appliance must be installed and commissioned by a fully qualified, registered engineer. A “Declaration of completion

Certificate” must be obtained for the installation and retained by the end user. Failure to comply with these requirements may void your warranty.

You, as the end user, have a contract by law with the supplier / dealer from whom you purchased the product. That dealer then has the same contract with the manufacturer or wholesaler and these have a contract with their suppliers.

ALL CLAIMS MUST FOLLOW THIS PROCEDURE.

Thank you for choosing a Product from Broseley Fires Ltd. This warranty gives you specific legal rights. The statutory rights of the consumer are not affected by the warranty, or the consumers’ rights against the dealer arising from their sales / purchase contract.

The manufacturers’ warranty:

Your Product will be free from defective parts, material, and workmanship at the time of its original purchase for a period of Two (2) years. This Warranty will become active as of one month from the date of delivery.

This warranty does not cover any failure of the unit due to normal wear and tear, misuse, abuse, accident, illegal modification, illegal installation or repair, damage resulting from improper use or failure to maintain the product. Variations in color and texture are a natural characteristic of cast iron products. Colour changes may result from exposure to light and other elements which are a part of the aging process. These material variations and changes are not covered by this warranty. If during the warranty period, this Product fails to operate under normal use and service, due to defects in material and / or workmanship, Broseley Fires will either repair or replace the product.The repaired or replaced product shall be warranted for the remaining period of the original warranty + the time taken to days from the date of repair, whichever is longer.

Repair or replacement may involve the use of functionally equivalent reconditioned units. Replaced parts or components will become the property of Broseley Fires.

Should you wish to claim under the warranty, please contact the supplier / dealer from whom you purchased the appliance. Do not claim directly to Broseley Fires, as they are unable to process any direct claim from an end user.

Product design and any specifications are subject to change without notice. This is due to our continuous product development and improvement. The buyer will not be entitled to request free upgrades to the new design or compensation for previously purchased products or any products on order.

• This Warranty covers all Broseley Fires costs within the Warranty period.

If the appliance remains uninstalled for a period greater than six months from date of delivery the Warranty will become active six months from the date of original invoice to the distributor.

I N NO EVENT SHALL B ROSELEY F IRES BE LIABLE FOR INCIDENTAL OR CONCEQUENTIAL DAMAGES OF ANY NATURE WHATSOEVER ,

INCLUDING BUT NOT LIMITED TO LOST PROFITS OR COMMERCIAL LOSS , TO THE FULL EXTENT THOSE DAMAGES CAN BE DISCLAIMED BY

LAW . (if applicable)

NON - COVERAGE OF THE GUARANTEE

The consumable items within the product are not covered by the warranty, nor is the glass

If the end-user’s claim should not be covered by this guarantee, the end-user shall be liable for costs incurred by

Broseley Fires such as callout and inspection costs for examination of the product, transportation costs of the product as well as any other relevant costs.

If, after having been informed about the non-coverage of the guarantee, the end-user wants to have the repairs done, the end-user shall additionally pay for any spare parts used and for the labour and transportation costs incurred. If repairs are carried out under this guarantee, the remaining guarantee period for the product shall be extended by the period of time that has elapsed since the complaint was officially logged with Broseley Fires until the repairs have been completed

A COPY OF OUR FULL TERMS AND CONDITIONS IS AVAILABLE ON REQUEST .

** End-user means the natural or legal person who owns the product and who has not acquired it with a view to reselling or installing it in the course of business