COUNTRY FLAME TECHNOLOGIES

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MODEL CF-04 CROSSFIRE STOVE

FIREPLACE INSERT, (PELLET FUEL VERSION)

USA & CANADA TEST:

ASTM E 1509-04, UL 1482,

TESTED BY:

WARNOCK HERSEY

ULC S627, ULC/ORD C1482 (and ULC S628

If listed for fireplace insert installation in Canada)

MOBILE HOME APPROVED

Oregon Administrative Rules 814-23-900 thru 909

Version 2.0e

WARNING: If the directions in this manual are not followed exactly, a fire may result causing property damage, personal injury or loss of life.

FOR YOUR SAFETY

Do not store or use gasoline or other flammables (vapor or liquids) in or around the vicinity of this appliance.

Installation and repair must be performed by a qualified service agency.

Always check with local jurisdiction or code agency before installing this product. Local jurisdiction may be requiring a permit prior to installation.

© 2009

COUNTRY FLAME

1

SAFETY NOTES

The Crossfire-Pellet Model fuel stove is significantly different from a conventional wood-burning stove.

One major difference is that the CF-04 requires a reliable source of electrical energy to properly operate.

The owner, installer, and operator must understand this manual and read it in its entirety. Understanding this manual should be completed and followed before installation or operation of the CF-04 is attempted.

Failure to follow installation and operation instructions or perform necessary maintenance can result in property damage, bodily injury, or even death. Country Flame strongly recommends that a certified professional install the Crossfire Model CF-04.

W

ARNING

:

THE AUTHORITY HAVING JURISDICTION ( such as a municipal building department, fire department, or fire prevention bureau, etc

) SHOULD BE CONSULTED

BEFORE BEGINNING INSTALLATION. A PERMIT MAY BE REQUIRED IN

ORDER TO PERFORM INSTALLATION.

W

ARNING

: A smoke detector is recommended to be installed in the vicinity of the Crossfire CF-04.

W

ARNING

: Country Flame Technologies has no control over installation or maintenance procedures; therefore, Country Flame grants no warranty, implied or written, for the installation or maintenance of the CF-04. Further, Country Flame assumes no responsibility for any consequential damage resulting from said installation or maintenance of this product.

W

ARNING

: After operation, always allow the Crossfire stove to completely cool before performing any maintenance operations.

W

ARNING

: The Crossfire stove requires reliable electric energy to properly operate. If electrical power is not available, DO NOT operate the Crossfire with only a natural draft.

W

ARNING

: Only a certified professional should install a Crossfire stove. Only a qualified service technician should perform maintenance on the Crossfire. Parts removed for installation or servicing must be replaced prior to operational use of this stove.

W

ARNING

: Modification of the Crossfire is not authorized and any modification to the Crossfire voids

Country Flame’s product warranty.

W

ARNING

: The Crossfire must be connected to a code compliant grounded 120-volt, 15 ampere, and

60 hertz electrical outlet. Use of a dedicated circuit is recommended. NEVER use an adapter, extension cord or cut or remove any prong from the power cord.

W

ARNING

: NEVER place or store any combustible or flammable products on or near the Crossfire.

W

ARNING

: The Crossfire is designed to shutdown in the event the front door is opened longer than 1 minute. Keep the viewing door tightly closed during operation. Always clean the

Crossfire after the stove has been allowed to return to normal room temperature.

W

ARNING

: Do not connect the Crossfire to a chimney flue serving another stove of any type and never install a flue damper in the exhaust system of the Crossfire.

W

ARNING

: FOLLOW all operating instructions in this manual. Short cuts in operating procedures, of any kind, can be dangerous.

Version 4.0 2

W

ARNING

: Maintain all minimum safety clearances of the Crossfire stove and chimney system.

Never install the Crossfire in a sleeping room.

W

ARNING

: The CF-04 PELLET stove is designed to burn PREMIUM HARDWOOD PELLETS

ONLY. Any fuel used in this stove must meet or exceed APFI standards. Do not burn untested fuels or foreign materials in this product. Failure to comply with fuel restriction voids Country Flame’s warranty and the safety listing of the unit. Poor quality fuel will directly (and adversely) affect efficiency and cleanliness of operation. Country Flame’s local authorized dealer can help in recommending a quality fuel

W

ARNING

: NEVER use gasoline, lantern fuel, kerosene, charcoal lighter fluid or other combustible liquids to start or “freshen up” the fire in this product. Do not store or use gasoline or other flammable liquids or allow combustible vapors in the vicinity of product.

W

ARNING

: Ensure free and adequate airflow to and around the Crossfire. This stove is a combustion system that requires continuous flow of fresh air for proper operation. Failure to provide an adequate fresh air supply can lead to operational problems such as: negative pressure in the home, poor operation of this or other home combustion appliances, or a host of other issues. Remember that other combustion appliances in the home compete for fresh air. Consult with a professional to ensure positive air flow is provided to the stove during operation.

W

ARNING

: The Crossfire’s exhaust system works with a negative combustion chamber pressure and a low positive chimney pressure. It is very important that the Crossfire’s exhaust system be airtight and properly installed. All exhaust joints connected to the Crossfire or each flue section is to be sealed. Use 500 degrees Fahrenheit (500

O

F or 260

O

C) silicone sealant or aluminum high temperature tape and secure each joint with (3) sheet metal screws. An improperly installed stove or chimney system is the major cause of home fires.

W

ARNING

: When installed in a mobile home, the Crossfire must be electrically grounded to the steel chassis of the mobile home. In addition, the stove must be bolted to a NON-

COMBUSTABLE surface. A mobile home installation of the Crossfire should be in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24.

Consult the local code authority.

W

ARNING

: SOOT AND FLY ASH: The products of combustion will contain small particles of fly ash. The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during start-up, shut down, or incorrect operation of the Crossfire will lead to soot formation in the exhaust venting system. Use the Crossfire cleanout ports to clean the exhaust venting system at least twice every year.

W

ARNING

: ASH REMOVAL: The ash should be emptied every day or as required to ensure proper operation. If the ash compartment is not emptied regularly, ash will build up and restrict the flow of fresh air in the combustion chamber. The airtight seal of the viewing door ensures a proper combustion process per the stove design and it should not be open during normal operation of the stove.

CAUTION: Operate the Crossfire with the fuel hopper lid closed at all times. Failure to keep the hopper lid closed during operation may result in the release of combustion gasses into the home from the hopper under certain conditions. Maintain the Crossfire hopper seal in good condition and do not overfill the hopper.

Version 4.0

3

CAUTION: The stove controls the rate of fuel fed into the fire pot. Never do anything to overfeed fuel or cause over firing of the Crossfire.

CAUTION:

THE

C

ROSSFIRE IS

H

OT WHILE IN OPERATION

.

DO NOT TOUCH

.

KEEP CHILDREN

,

CLOTHING

,

AND FURNITURE AWAY

.

CONTACT WITH HOT SURFACES MAY CAUSE

SEVERE SKIN BURNS

.

REFER TO THE SAFETY LABEL FOR INSTRUCTIONS

.

NOTE

: RETAIN this MANUAL for future reference as needed. Ensure the manufactured date and serial number of the Crossfire are written down for use should maintenance be required.

EPA STANDARDS

The Country Flame Crossfire meets rigorous emission standards. All Country Flame Crossfire Model CF-

04 stoves conform to United States Environmental Protection Agency standards.

LISTING/TESTING AGENCY

The Crossfire Model CF-04 has been independently tested and listed in accordance with ASTM E1509-04,

UL 1482, ULC S627, ULC/ORD C1482 (and ULC S628 if listed for fireplace insert installation in

Canada) and Oregon Administrative Rules 814-23-900 – through 909. This listing is for installation into residential dwellings, including standard construction units, mobile home units, or modular home units.

The Crossfire Model CF-04 was tested to UL standards by Intertek Testing Services, NA, Inc., 8431

Murphy Drive, Middleton, WI 53562.

Version 4.0

4

CERTIFICATION SAFETY LABEL (sample)

Version 4.0

5

TABLE OF CONTENTS

SAFETY NOTES.........................................................................................................................................2

EPA STANDARDS ..................................................................................................................................4

LISTING/TESTING AGENCY ................................................................................................................4

CERTIFICATION SAFETY LABEL (sample) .......................................................................................5

TABLE OF CONTENTS............................................................................................................................6

FORWARD..................................................................................................................................................8

COUNTRY FLAME .................................................................................................................................8

CROSSFIRE LIMITED WARRANTY ...................................................... Error! Bookmark not defined.

CROSSFIRE LIMITED WARRANTY (continued).................................. Error! Bookmark not defined.

THE CROSSFIRE OPERATION ...........................................................................................................12

FEATURES.............................................................................................................................................12

SAFETY FEATURES.............................................................................................................................13

BATTERY BACKUP SYSTEMS ..........................................................................................................13

FUEL REQUIREMENTS .......................................................................................................................14

CROSSFIRE STARTUP.........................................................................................................................15

ASH REMOVAL ....................................................................................................................................17

Intelli-Choice CONTROL BOARD ........................................................................................................18

CONTROL BOARD FACE ILLUSTRATION……………………………………………………… 20

CONTROL BOARD TROUBLESHOOTING CODES…………………………………………….. 23

STOVE ELECTRICAL DIAGRAM ………………………………………………………………… 25

STOVE SPECIFICATIONS ...................................................................................................................26

ELECTRICAL REQUIREMENTS.........................................................................................................26

GOLD DOOR CARE..............................................................................................................................26

OPTIONAL FEATURES........................................................................................................................26

OPTIONAL THERMOSTAT OPERATION..........................................................................................26

CROSSFIRE IS COLD .......................................................................................................................26

CROSSFIRE IS HOT..........................................................................................................................26

CHANGE HEAT LEVEL (thermostat active) ....................................................................................27

CHANGE HEAT LEVEL (thermostat inactive).................................................................................27

COMBUSTION FRESH AIR CONTROL .............................................................................................27

INSTALLATION ......................................................................................................................................28

INSTALLATION PREPARATION .......................................................................................................28

STOVE CLEARANCES.........................................................................................................................28

SHROUD INSTALLATION...................................................................................................................29

CHIMNEY ..............................................................................................................................................30

FACTORY-BUILT CHIMNEY..............................................................................................................30

MASONRY BUILT CHIMNEY.............................................................................................................30

FLOOR PROTECTION REQUIREMENTS ..........................................................................................31

OUTSIDE AIR COMBUSTION.............................................................................................................32

MOBILE HOME INSTALLATION .......................................................................................................33

6

MOBILE HOME RULES .......................................................................................................................33

MOBILE HOME CLEARANCES..........................................................................................................33

MOBILE HOME STOVE ATTACHMENT...........................................................................................34

MOBILE HOME FLOOR PROTECTION .............................................................................................34

MOBILE HOME CHIMNEY AND DUCTS..........................................................................................35

MAINTENANCE REQUIREMENTS ....................................................................................................38

GENERAL REQUIREMENTS...............................................................................................................38

STOVE DOOR INSTALLATION..........................................................................................................38

STOVE DOOR ADJUSTMENT.............................................................................................................39

STOVE DOOR GLASS CLEANING.....................................................................................................39

GLASS REPLACEMENT ......................................................................................................................39

GLASS-CERAMIC SPECIFICATIONS ................................................................................................40

GASKET REPLACEMENT ...................................................................................................................40

CROSSFIRE CLEANING ......................................................................................................................40

APPENDIX A: TROUBLESHOOTING GUIDE..................................................................................43

APPENDIX A: TROUBLESHOOTING GUIDE (CONT’D) ..............................................................44

APPENDIX B: MAINTENANCE GUIDE.............................................................................................45

APPENDIX B: MAINTENANCE GUIDE (CONT’D) .........................................................................46

APPENDIX B: MAINTENANCE GUIDE (CONT’D) .........................................................................47

APPENDIX C: TECHNICAL SPECIFICATIONS ..............................................................................48

APPENDIX D: CROSSFIRE THEORY OF OPERATION ................................................................49

APPENDIX D: THEORY OF OPERATION (cont’d)..........................................................................50

COOL DOWN PHASE ...........................................................................................................................49

FAULT PHASE ......................................................................................................................................50

RESET CONDITION..............................................................................................................................50

SYSTEM MAINTENANCE...................................................................................................................50

APPENDIX E: COMBUSTION BASICS ..............................................................................................52

APPENDIX F: REPLACEMENT PARTS ............................................................................................56

REPLACEMENT PARTS ......................................................................................................................56

REPLACEMENT PARTS ......................................................................................................................57

APPENDIX G: LABELS .........................................................................................................................58

REPLACEMENT LABELS....................................................................................................................58

REPLACEMENT LABELS....................................................................................................................59

7

FORWARD

COUNTRY FLAME

Country Flame has worked for over two decades in researching and developing biomass fuel burning stove products. In 2002, Country Flame received a national award from the Hearth Industry for its

HARVESTER freestanding biomass fuel stove. Country Flame has now added the CROSSFIRE

FIREPLACE INSERT pellet fuel stove to its line of products. The CROSSFIRE gives every homeowner the opportunity to convert their inefficient fireplace into a highly efficient heating machine. In addition, the CROSSFIRE ensures that the homeowner can choose from an ever growing array of fuel products to meet their home heating needs. Country Flame is dedicated to researching and developing advanced pellet stove products. The Crossfire Model CF-04 was designed to burn APFI approved wood pellets or shelled corn. Switch grass pellets and other fuel may be burned in the Crossfire but results have not been verified.

THE PURCHASE OF A COUNTRY FLAME CROSSFIRE STOVE IS A VOTE TO REDUCE

AMERICA’S DEPENDENCE ON FOREIGN OIL. Country Flame is very proud of this American born,

American tested, and American made product. With pride and dedication, Country Flame employees wish you and your family a lifetime of happiness and warmth through the use of our products.

LET US PUT A FLAME IN YOUR HEART

h

!

8

AMERICAN ENERGY SYSTEMS INC. LIMITED PRODUCT

WARRANTY

This warranty is in effect on all products sold after 01/01/2009 and supersedes any and all warranties currently in existence.

Please keep a copy of this warranty for your personal records or in the event of a claim

American Energy Systems Inc., hereinafter referred to as (AES), warrants to you, the original consumer purchaser, that this product is free from defects in material and workmanship for a period of five (5) years from the original purchase date minus any time past one (1) year from manufacturing date, and that the product’s electrical parts and steel firepot, are free from defects in material and workmanship for a period of one (1) year from the original consumer purchase date minus any time past one (1) year from manufacturing date, and that the cast iron firepot models carry a lifetime warranty against defect in material or workmanship (excluding war page or deterioration), and that door glass carries a lifetime replacement warranty against heat breakage (does not cover accidental breakage) . There is expressly no warranty on installation of product, any venting, grates, gaskets, door latches, insulation, ceramic or brick boards/logs/backing, paint, plated surfaces/doors/trims, baffles, bushings, bearings, auger flightings, war page or discoloration of steel or plated parts or any other normal wearing part. In the event the product fails to conform to this warranty, AES, through the place where you purchased the product or if purchased on the AES E-Com store directly through AES, will provide the parts and components necessary to remedy such nonconformity. AES will not be responsible for any labor, mileage or freight cost to the factory under this

warranty. This warranty is not transferable.

In order to obtain performance under this warranty, you must (1) have registered this warranty within 30 days of purchase by completing and returning the warranty registration card or filling in the on-line warranty registration form at www.magnumheat.com, and (2) promptly report the claimed nonconformity to your place of purchase, also providing your name, address, phone number, proof of purchase, date of purchase, the model and serial number of the stove, digital pictures of installation and venting inside and outside of the home, pictures of the claimed nonconformity part and the claimed nonconformity. All claims must be submitted in writing to your

place of purchase.

AES shall have no warranty obligations if this product; (1) was not purchased from an authorized AES dealer; (2) was not installed by a AES dealer or other qualified installer; does not have outside combustion air hooked directly to the unit; (3) was not operated and maintained in strict accordance with the manufacturer’s instructions, local or national codes or (4) was subject to abuse, misuse, negligence or accident. AES shall have no warranty obligation for damage caused by improper handling, freight damage (must be reported to freight provider), over-firing, unapproved fuel, variance in feed rates, variances in BTU output or the unauthorized disassembly or modification of the product. AES shall have no warranty obligation if this warranty is not timely registered, for claims which are not submitted through the selling AES dealer, or for claims submitted verbally or without the required information and documentation.

Before exercising this warranty, an AES representative (the place where the product was purchased or AES approved person) must inspect the part/unit to determine if the part/unit is defective. If a local AES representative is not available the original purchaser of the product must submit digital pictures of the part/unit, installation of the unit to AES at [email protected]

If the inspection reveals that the failure is due to defective material or workmanship and the part is covered by the conditions of this warranty, AES will, at its option, repair the defective part/unit. The sole duty of AES and liability under this warranty is limited to the repair of the covered defective part/unit. The purchaser shall assume all costs related to shipping the replacement parts or return of the unit to the factory for repairs. If it is determined that the defect was caused by AES, AES will cover the costs of shipping the repaired part/unit to an AES approved shipping point. AES will not cover additional freight or delivery services such as residence delivery charges, special handling, etc.

INSTALLATION, VENTING, REMOVAL OR REINSTALLATION COSTS ARE NOT COVERED BY

THIS WARRANTY.

THE WARRANTY PRINTED ABOVE IS THE ONLY WARRANTY APPLICABLE TO THE

PRODUCT. ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT

LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A

9

PARTICULAR PURPOSE, ARE DISCLAIMED. IT IS UNDERSTOOD AND AGREED THAT

AES’S LIABILITY UNDER THIS WARRANTY SHALL BE LIMITED TO THE PROVISION OF

REPLACEMENT PARTS AND SHALL NOT INCLUDE LIABILITY FOR SPECIAL, INCIDENTAL

OR CONSEQUENTIAL DAMAGES. ANY ACTION BROUGHT UNDER THIS WARRANTY

MUST BE BROUGHT WITHIN ONE YEAR OF THE ACCRUAL OF THE CAUSE OF ACTION

AND MAY ONLY BE BROUGHT IN THE CIRCUIT COURT OF MCCLOUD COUNTY,

MINNESOTA.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

ALL WARRANTY CLAIMS MUST BE SUBMITTED IN WRITING THROUGH THE PLACE WHERE THE

PRODUCT WAS PURCHASED. In the event where the place of purchase has ceased business or if you feel that there is a legitimate reason that you cannot submit your claim to the place where the product was purchased you may make a written request to the factory by emailing your request along with all of the required information to [email protected]

. NOTE: Verbal requests will not be recognized. If it is determined that

warranty could have been performed by the place of purchase, the factory will deny the claim.

Included with the claim must be the following information: (if this information is not complete, the claim will be denied)

Name, address, telephone number, email address, of place of business where product was purchased & also purchaser contact info.

Date of purchase, model and serial number of product, digital pictures of product (front, sides, back, venting inside and outside)

(If there is ductwork, there must be digital pictures of entire ductwork installation, static pressures, air flow measurements, and contact information of licensed/factory certified contractor that installed unit)

Nature of defect, what has been serviced (service record), who installed product along with contact information.

10

American Energy Systems, Inc.

150 Michigan Street SE

Hutchinson, MN 55350

Fold Here

Name Address

Zip

Dealer

Dealer’s Name

Date of Purchase

Zip

No.

The express warranties made by Country Flame Technologies do not apply unless this warranty card is received by Country Flame Technologies from the original retail purchaser no later than thirty

(30) days subsequent to the date the Country Flame product was originally purchased.

Signature Date

11

Place

Stamp

Here

THE CROSSFIRE-PELLET OPERATION

FEATURES

Country Flame designed and built the Crossfire-Pellet stove to burn 100% premium hardwood pellets. Unlike conventional pellet stoves, the Crossfire was designed to handle large amounts of ash. Country Flame is pleased that customers are finding wide success in burning locally available fuels but Country Flame cannot support or warranty the burning of untested fuel in the Crossfire.

Before beginning to install or operate the Model CF-04 Crossfire, please consult with the local building authority to obtain a permit and ensure a professional installs or certifies the installation of this product.

Before a homeowner operates this stove, a thorough operational understanding should be obtained from reading and understanding this manual. Failure to adhere to all safety notes and instructions contained herein can impact homeowner insurance, void warranty, and create hazardous situations leading to a smoke damage, fire, or even death.

The Model CF-04 was designed as an insert only model stove. The Crossfire was designed to be installed into an existing zero clearance fireplace or an existing masonry fireplace. Contact Country Flame or one of its local authorized dealers to discuss and select possible options that are available for the Crossfire. Once installed, the Crossfire is remarkably simple and safe to operate. FIGURE 1 and FIGURE 2 defines Crossfire components. From a relatively small firebox the Crossfire generates a beautiful flame with lots of heat being produced into the room where the unit is installed. Clean AFPI approved fuel is to be loaded into the hopper.

A motor turns an auger that delivers fuel to the combustion chamber on a timed basis.

Air

Vent

Hopper

Lid

Hot Air

Discharge

Room Air Fan

Control Board

Front Vent

Power On/Off Switch

Power

Connector

Glass

(Ceramic)

Combustion

Air Control

Removable

Hearth Plate

FIGURE 1: CROSSFIRE MODEL CF04-PELLET

12

Door

(Cast Standard)

FIGURE 2: CROSSFIRE COMPONENTS

SAFETY FEATURES

The Crossfire comes standard with a number of advanced safety features; however, to ensure maximum safety install the stove according to all national and local codes and follow all operating and maintenance procedures. The Crossfire requires a fresh air supply to ensure proper combustion. This fresh air is used in the combustion process to achieve thorough burn of all fuel. The Crossfire needs a sealed and properly designed exhaust flue system. This exhaust flue will be used to remove combustion gasses outside the home.

REMEMBER: one of the leading causes of house fires is due to improper installation or improper operation of a stove product. Proper installation and operation of the Crossfire is required to obtain Homeowner insurance coverage. And, the Crossfire needs a reliable source of electrical power. Without reliable utility power or a means to ensure reliability, the Crossfire operation will be problematic.

It will require some effort and learning for the homeowner to thoroughly understand the operating characteristics of the Crossfire. More importantly, the operator needs to know how to control each one of the stove’s operations. The Crossfire has an electronic control system that is constantly monitoring stove operations in order to ensure fuel combustion efficiency and to ensure maximum heat output of this product.

The Crossfire’s electronic control provides a simple one stop location for the homeowner to control Crossfire performance. To ensure safe operation, the Crossfire’s electronic control is constantly monitoring pressure and heat activated switches, and input power to ensure proper operation. Additional features include an enclosed firebox, high temperature ceramic glass, optional thermostatic control, a high temperature wiring harness, making the Crossfire an extremely safe stove.

BATTERY BACKUP SYSTEMS

The Country Flame Crossfire Model CF04-PELLET, relies on electrical energy (wall power outlet) to properly operate. Without electrical energy or with interruptions to the source of electrical energy, the

Crossfire stove’s operation will be erratic at best. Is power quality, power reliability, or routine winter storm conditions a cause of power problems in a specific locale? If it is, the homeowner will need to provide

13

backup power to ensure stable operation of the Crossfire. Uninterruptible power supplies (UPS) include the capability to handle power failures, brown outs, power surges, line noise, and sell for around $35 to $150.

UPS system cost is largely defined by the features included and the amount of time (battery size) the UPS can operate before recharging of the battery is required. UPS systems are sold by the number of electrical outlets, the volt-amperes (watts), and the additional features included.

FUEL REQUIREMENTS

The Crossfire Model CF04-PELLET was designed to burn PREMIUM HARDWOOD PELLETS only. Not all fuels have been fully tested so results may vary depending on the grade of fuel being burnt.

Country Flame recommends no more than 8% moisture content in the type of pellets being used. The American Pellet Fuel

Institute establishes standards for pellet fuel manufacturer’s product. Pellet Manufacturers voluntarily follow these standards but homeowners should know what to look for. The following terms should be understood by the homeowner:

ASH:

Pellet stoves produce two kinds of ash:

1) Solid ash residue in the firepot.

2) Fly ash (un-burnt particles) and air born fly ash (sparklers) are created during the combustion process. The

Crossfire has an ash compartment which aids in cleaning the stove. Ash can also accumulate in "ash traps" which need to be cleaned periodically. The remaining fly ash is blown into the flue system which will also require periodic cleaning.

FINES:

(sawdust): Fines are caused by pellet disintegration that occurs during transport or storage of pellets.

Two potential problems – fines can create dust in the home and fines cause interference to the flow of pellets in the fuel hopper.

SIZE:

The Crossfire can handle a wide variety of pellet size. Variations in pellet size create no problem but smaller size pellets usually feed at higher rates per Crossfire heat setting and can affect the balance of air-tofuel. Extra long pellets may create bridging in the hopper which will starve the Crossfire for fuel.

BTU's:

(heat) PER POUND: The variation of BTU's per pound in pellet or is usually not noticeable to most users. Overall stove efficiency (combustion efficiency times heat transfer efficiency) has a greater impact on the heat delivered to the home.

DENSITY:

Pellet density (measured in pounds per square foot) determines the maximum amount of energy that can be delivered to the combustion chamber. Low density fuels may cause the fire to go out on low heat settings without proper adjustments to the air-to-fuel ratio.

SALT:

Salt in pellets can cause stove deterioration (rust). The Pellet Fuels Institute is participating in tests to determine the effects of salt and the most accurate methods of measurement. The APFI will publish standards that will result in recommended standards for sodium in pellets.

CLINKERS:

Clinkers are the result of impurities in pellets

. Clinkers may also occur due to ash fusion (ash melted together in the burn pot), and can be minimized by properly adjusting the air-to-fuel ratio.

DIRTY GLASS:

Glass becomes dirty during normal or faulty combustion. Some fuels produce a film on the glass to which ash adheres, making a clean glass more difficult.

Pellet fuel manufacturers should be able to show test results for BTU's, ash content, and the amount of fines

in their product. Do not hesitate to contact the pellet manufacturer if you have questions or concerns. If questions remain about the Crossfire, please contact a local authorized Country Flame Dealer for assistance.

14

CROSSFIRE STARTUP

The first step in preparing the Crossfire for use is to remove it from its shipping crate. Ensure that all materials packed in the burn chamber have been removed. Ensure proper cleaning of the Gold (optional plated) door/trim and clean all glass per instructions included in this manual.

NOTE: Failure to properly pre-clean the Gold (or any plated) door or trim and the glass before lighting the first fire could permanently damage these items.

START UP PROCEDURE

(SEE FIGURE #3)

1. Ensure that the CF04-Pellet stove has been installed correctly, and that the manual has been read and thoroughly understood.

2. Fill hopper with Premium Hardwood Pellets, close hopper lid.

3. Turn power toggle switch to the “ON” position, (Control Board will light up.)

4. If the auger has been previously primed or the stove was operational and shut down without running out of fuel, proceed to step no# 6.

5. “Prime” the auger system of the new pellet stove, or a stove that previously has run out of fuel. This is done simply by pressing and holding down the control board

“ON/OFF” button (located at the bottom of the control board) until the “Green”

auger feed light starts to flash, (approx 15 seconds) then release button. Prime mode will take approx. 10 minutes, when you see pellets begin to drop into the burn-pot press and hold the control board “ON/OFF” button for approx. 5 seconds. (The green light next to the “ON/OFF” button should turn to red, then release.) NOTE: While in the prime mode the heat setting indicator lights will continue to flash from low to high.

6.

IGNITION PROCEDURE: Simply press and hold the “ON/OFF” button at the

bottom of the control board for approx. 5 seconds. (The light next to the button will turn from red to green, then release.) The light next to the igniter symbol will come on

(red) and the Auger light (green) will start to flash after a slight delay.

7. Close the inlet air damper lever completely. (Pull towards the front of the stove) After approximately 3 minutes or so open the inlet air damper about 1/2”, the inlet air added to the smoking pellets should cause ignition. If this does not occur, close damper completely for another minute or so then repeat.

8. After ignition, the stove will automatically go into the operational sequence after reaching the appropriate internal temperature. When the ignition cycle is complete the stove will start up in heat setting #3. NOTE: adjustment to the air inlet control

will be necessary for proper startup.

15

9. Heat settings are changed by pressing the red or blue arrow buttons. Note: Inlet air adjustments will/may be required for each temperature setting change. It is best to only change one level at a time and allow the stove to stabilize.

10. See information on required Cleaning in the maintenance section of this manual.

FIGURE 3

Power Switch

On/Off Button

(Control Board)

Combustion Air Control

REFERENCE OPERATING INFORMATION

(SEE FIGURE #3)

DO NOT turn main power switch “OFF” during stove operation. The stove must

complete normal cool down cycle prior to shutting power off. (Failure

to do so could cause a backup of smoke into the heating area if the stove is not properly vented)

• The Room-Air blower has power to it at all times and will run continuously when the main power switch is in the on position.

• After initial ignition and system start up, allow the stove adequate time to burn and heat up at the preset #3 level prior to increasing heat setting.

16

• If a heat setting change is made more than one bar at a time, (red and blue arrow keys) there is a 2 minute response delay in the exhaust fan speed for each level increase.

This will require the air inlet control setting to be modified / observed throughout the setting change.

• A visual reference to the Ideal burn condition of pellets would show a fuel level in the

Burn-Pot well “BELOW” the stir rod at ALL TIMES. This will prevent any possibility of an over feed condition. The fuel feed rate can be regulated by the potentiometer on the back of the control board.

• The higher the heat level setting on the stove the more inlet air required for a complete burn of the pellets. Setting No# 5 will require significantly more air than setting No#1. Adjust the inlet control lever accordingly. (To the front of the stove is

CLOSED, see manual for illustration)

STOVE SHUT-DOWN PROCEDURE, during normal operation, simply push the

“ON/OFF” control button, (bottom of the control pad) and hold it for approx. 5

seconds or until the lights on the heat level settings start to flash from top to bottom, then release. The stove is now in its cool down cycle. Only after the system has performed all cool down functions and the control board is back to an “OFF” state,

can the main AC power switch be turned off.

• All questions or concerns about operational issues should be directed to your local

Country Flame Dealer.

The stir rod will be controlled by the “Intelli-Choice” control board. This stir rod assists in mixing fuel with air in the burn pot. The stirring action improves the mixing of oxygen and fuel and accelerates the combustion process. As heat settings are changed on the Intelli-Choice control board, the stir rod speed will automatically be adjusted to more closely match the feed rates of the different heat settings.

The stir rod assists in minimizing “clinker” build-up in the burn pot. If the proper air-fuel mixture is set by the homeowner, the Crossfire will generate a very fine ash rather than clinkers. In addition, the stir rod ensures that the fuel and flame are constantly agitated within the burn pot to enhance the combustion process.

The Crossfire burn pot has been designed to ensure maximum efficiency of burn while minimizing the amount of ash being produced at the same time minimizing the clinkers that might choke out a fire. Testing by Country Flame has shown that the Crossfire can be continuously operated for several days without requiring cleaning. It should be recognized by the homeowner that environmental variables as well as the type of fuel being burnt can have dramatic effect on the amount of ash or clinkers formed during the burn cycle. Burn pot cleaning will depend upon the quality, quantity, and moisture content of the fuel. Ash removal will be required from time to time depending on the amount of usage and the heat output required.

The Crossfire stove should be shut down and cooled before cleaning or removing any ash from the firebox.

ASH REMOVAL

The Crossfire stove has a deep ash container built into the firebox. There is no removable ash pan located within the Crossfire. This means the operator must allow the ash to properly cool and then vacuum the ash from the stove with an industry approved ash vacuum. Once the ash has been removed from the firebox, it

17

should be stored or disposed of in proper containers. Failure to properly handle ash, even when the ash is believed to be completely cool, can lead to a fire.

Protective gloves should be worn anytime ash is removed. Dump all ash into a proper ash container and remove to a safe outdoors area. Remember that although the ash may look and feel cool to the touch, a smoldering ember can start a fire. CAUTION: Care should be used to store any ash in a proper container with an approved airtight lid. If ash is taken outside, water should be poured over the ash to ensure no fire flare up can occur.

Intelli-Choice

CONTROL BOARD

In 2001 Country Flame introduced its own control board technology, called the “

Intelli-Choice.

” Country

Flame’s control board technology was introduced across all pellets and corn stove product lines. The

Intelli-

Choice

control board is being used exclusively on Country Flame product. This control board technology was developed to ensure better support to customers. Country Flame will seek to provide the most advanced controls while maintaining the look and feel our dealers and customers have come to know and expect.

Country Flame also wants to ensure its product can be upgraded to newer and more advanced technology if and when this technology becomes available and the customer chooses to obtain it. Country Flame is committed to its customer base. . Country Flame’s goal is to ensure a certified service technician can diagnose and repair any stove problem in less than 30 minutes. FIGURE 4A depicts control board basic theory and FIGURE 4B provides a brief description of sensor controls.

18

VACUUM

SENSOR

OVERTEMP

SENSOR

FUEL

CONTROL

COMBUSTION

AIR CONTROL

Hopper

Switch

THERMOSTAT

(Optional)

INPUT VOLTAGE

120 Volts AC 60 Hz

15-Ampere Circuit

Fuse

6 – 9

Amperes

EXHAUST

TEMPERATURE

SENSOR

CONTROL BOARD

ON/OFF SWITCH

TEMPERATURE CONTROL

POWER/FUEL/IGNITER/ INDICATORS

ROOM AIR

TEMPERATURE

SENSOR

ROOM AIR

CONTROL STIR ROD

STOVE

FIGURE 4A: CONTROL BOARD BLOCK DIAGRAM

Input Voltage

Fuse

Alternating Current (AC) Input provided by the local power company. This source of energy must provide a 120 Volt input signal with a frequency of 60 Hertz and a maximum branch current capacity of 15 Amperes. If other devices are connected to the branch, interference or over current may cause circuit breaker to trip.

The AC fuse should be rated between 6 and 9 amperes. The recommended fuse is a Little

Fuse Model _______.

Vacuum Sensor

Exhaust Temperature Sensor

Ensures that no blockage of the combustion input or combustion exhaust air occurs. If the vacuum sensor does not operate properly, the Control Board will not allow the stove to operate.

Presently, this sensor is a snap disk operating at 110 o

F +/- 20 o

F. This sensor ensures proper exhaust temperature has been reached and that a fire is present in the burn pot before the control system begins the burn cycle.

Room Air Temperature Sensor

Presently, this sensor is a snap disk operating at 110 o

F +/- 20 o

F. This sensor ensures that a proper amount of heat is available at the heat exchanger before the room fan is allowed to operate. If the sensor allows the fan to come on to early, the combustion chambers

Overtemp Sensor

Fuel Control

temperature could drop to the point that self-combustion (ignition temperatures) cannot be maintained.

Presently, this sensor is a snap disk operating at 250 o

F +/- 20 o

F. The purpose of this sensor is to shut the entire system down in the event the firebox causes an overheat condition.

The fuel control is a signal provided from the Control Board to the Auger Feed Motor. The

Control Board controls the amount of time that the Auger Feed Motor is on and thereby controls the amount of fuel fed to the fire pot.

Room Air Control

Combustion Air Control

Stir Rod

The room air control is a signal provided from the Control Board to the Room Air Fan. The

Control Board controls the phase angle and thereby the amount and time an AC voltage is applied to the Room Air Fan. This signal controls the speed of the room air passing over the heat exchanger tubes and the amount of heat delivered to the living space.

The combustion air control is a signal provided from the Control Board to the Combustion

Fan. The Control Board controls the phase angle and thereby the amount and time an AC voltage is applied to the Combustion Air Fan. This signal controls the speed of the combustion air passing through the burn pot for the different heat settings

An AC device used to create turbulence in the burn pot. The stir rod reduces the potential of a klinker thereby ensuring more efficient combustion process. The operator must remove and clean the stir rod from time to time. Be careful not to damage or break the stir rod.

Thermostat (optional) A thermostat input is provided on the back of each Country Flame product. The Control

Board has individual personality modules that allow for stand-alone or semi automatic thermostat operation.

FIGURE 4B: STOVE COMPONENT DEFINITIONS

19

FIGURE 5 displays the Country Flame Control Board front panel. Each function of the Control Board is identified. Controls having more than a single function are identified with asterisks. All control board functions are explained in FIGURE 6.

“Intelli-Choice”

Country Flame Logo, AC

Power is present when logo is lit.

Lighting Symbol

Auger Feed Symbol

High Heat Setting

Red When Lit

Medium Heat Setting

Yellow When Lit

Slow/Fast Blink depending on ‘on state.’

Auger Feed Light,

Green when Auger is on

* Heat Up Switch

Low Heat Setting

Yellow When Lit

*Heat Down Switch

*ON/OFF Switch *DC Power on Light

Red, System Off

Green, System On

Yellow, System Dirty

FIGURE 5: CONTROL BOARD FACE PLATE

20

ON/OFF SWITCH

HEAT UP/ HEAT DOWN SWITCH

DC POWER LIGHT

HIGHWAY PATROL MODE

COOL DOWN MODE

HEAT SETTING 1 THROUGH 5

The

Intelli-Choice

ON/OFF Switch either turns the system on or off by holding the switch for approximately 5 seconds. The ON/OFF Switch can also be used to initiate the FUEL PRIME MODE by holding it for approximately 30 seconds.

When in the prime mode the Thermostat lights will sequentially light from top to bottom simulating a “filling action” of the auger tube.

These switches only function as heat up and down switches.

This is a 3-color light when AC power is applied. A red light indicates that the

Control Board has DC Power available but the system is off. A green light indicates that the System is on. A yellow light indicates that the combustion air should be cleaned. As Country Flame works to improve the sensor technology, this yellow light will become more valuable to the service technician as well as the homeowner.

When all Control Panel lights are flashing on and off, this indicates that the

Product has an encountered an unknown state. Nothing more, nothing less. The purpose of these flashing lights is to alert the home owner or the service technician that the stove operation ended out of sequence, ran out of fuel, or encountered a power interruption that the Control System could not recover from.

In the Cool Down Mode, the Heat Setting lights will sequentially go out from top to bottom, all relight and then sequentially go out from top to bottom. This cycle will continue until such time that the Control Board senses the stove has properly cooled down.

Each heat setting, controlled by the stove Heat Up or Heat Down switch, is provides as much combustion air and fuel as is required for that heat setting. Due to the number of unique environmental variables as well as variations in pellet fuel used in different regions, Country Flame cannot provide exact BTU ratings for each heat setting except those that were established in Government Test Labs under controlled conditions. At the same time, the rule of thumb is that each heat setting on the Country Flame line of Biomass Product starts at one pound of fuel per hour and increments to a top setting of five pounds of fuel per hour. Using a

BTU rating of from 4,000 to 10,000 BTU per pound of fuel, depending on the type and moisture content of the fuel, an estimate of heat output can be made.

FIGURE 6: CONTROL BOARD FUNCTIONS

Country Flame’s control board provides reliable control of stove functions with minimal human intervention required. This control technology provides flexibility in adapting to future changes and improvements in technology. Finally, this control technology offers a simple interface between the operator and the product being used.

Country Flame’s control board is sensitive to utility grid power variations. In the event a homeowner’s area has difficulty with utility power fluctuations, Country Flame’s stove products can be interfaced to an inexpensive battery back up system. The actual cost of a battery backup system will be fully dependent on customer requirements. From random power “glitches” or short duration electrical power interruptions to major power outages, the Country Flame stove can operate off battery or generator backup systems. Contact

Country Flame or one of its local authorized dealers to discuss the specifics of a single application.

As always, Country Flame welcomes input on how to better meet the customer’s needs.

21

In order to utilize the full capabilities of the Control Board, the homeowner should be familiar with the backside of the Control Board. FIGURE 7 provides additional information about the major components on the component side of the control board.

FIGURE 7: CONTROL BOARD COMPONENT SIDE

22

TROUBLESHOOTING CODES

FOR

COUNTRY FLAME CONTROL BOARD

The following table provides additional information as to the reason different fault codes may be observed.

The table of information assumes that proper AC voltage, AC line frequency, and a properly working control board are available to and installed in the stove product.

Intelli-Choice Code Display

Possible Causes For Code Displayed

Code 0

System should exhibit Code 0 when the power is first supplied to stove product. After a few seconds, the vacuum switch should pull closed and cause a Code 1 to be displayed. If Code 0 remains, this means the (a) control board is defective, (b) the vacuum switch is defective, (c) the vacuum line is plugged between the vacuum switch and the combustion exhaust fan, or (d) the wiring between the control board and the vacuum switch is defective. The

Control Board provides 5 volts DC to the vacuum switch and checks for its presence. The vacuum switch is normally closed. When the combustion exhaust fan creates enough vacuums, the vacuum switch opens, removing the

5VDC signal and telling the control board a vacuum is

present. This is the START-UP CYCLE.

Code 1

Intelli-Choice Control Board recognizes the vacuum switch is

operating properly. Stove will go from START-UP

CYCLE TO IGNITION CYCLE.

Code 2

Intelli-Choice Control Board recognizes a vacuum is not present

AND the overtemp snap disk is hot. A wiring problem has occurred, OR two components (vacuum switch and overtemp disk) are bad, which is highly unlikely.

Code 3

Intelli-Choice Control Board recognizes overtemp disk is hot. A wiring problem has occurred, OR the control board is bad, OR the overtemp disk is bad.

Code 4

Intelli-Choice Control Board recognizes a vacuum is not present

AND there is a problem with the exhaust snap disk, OR the room air snap disk OR there is a wiring problem. IF the stove has ever been operating properly, the likelihood of two items failing at the same time is highly unlikely.

Code 5

Intelli-Choice Control Board recognizes a problem with the exhaust snap disk, OR the room air snap disk OR there is a wiring problem. It is most likely a problem with the exhaust snap disk if the stove has been operating properly previous to

Code 5 being displayed.

Code 6

Intelli-Choice Control Board recognizes a vacuum is not present

AND there is a problem with the exhaust snap disk, OR the room air snap disk AND the overtemp snap disk OR there is a wiring problem. If the stove is cool then both the room air snap disk and overtemp snap disk are bad, which is highly unlikely; therefore it is most likely the exhaust snap disk and the vacuum has become plugged with soot as the stove cooled down.

Code 7

Intelli-Choice Control Board recognizes a problem with the exhaust snap disk, OR the room air snap disk AND the overtemp disk, OR there is a wiring problem. It is most likely a problem with the exhaust snap disk if the stove has been operating properly.

Code 8

Intelli-Choice Control Board recognizes a vacuum is not present

AND there is a problem with the room air snap disk, OR there is a wiring problem. It is most likely the room air snap disk with a clogged vacuum if the stove has been operating properly.

Intelli-Choice Code Display

Possible Causes For Code Displayed

23

Code 9

Code A

Code B

Code C

Code D

Code E

Code F

Code L

Code P

Intelli-Choice Control Board has completed the IGNITION

CYCLE and is switching to the BURN CYCLE. The igniter should shut down to conserve energy and the stove will now watch for the room air snap disk to close before recognizes a problem with the exhaust snap disk, OR the room air snap disk, OR there is a wiring problem. If the stove is cool, it is most likely the exhaust snap disk. If the

stove is hot, it is most likely the room air snap disk.

Intelli-Choice Control Board recognizes a vacuum is not present

AND there is a problem with the snap disks, or there is a wiring problem. If the stove is cool, then it is most likely the exhaust and overtemp snap disk. If the stove is hot, then it is most likely the room air snap disk OR there is a wiring problem. The vacuum has plugged due to improper airflow or inefficient burn process.

Intelli-Choice Control Board recognizes there is a problem with the snap disks. If the stove is cool, then it is most likely the exhaust and overtemp snap disk. If the stove is hot, then it is most likely the room air snap disk, OR there is a wiring problem.

Intelli-Choice Control Board recognizes a vacuum is not present

AND there is no problem with the snap disks if the stove is hot and has not reached overtemp condition. If the stove is cool, then both exhaust and room air snap disk are bad OR there is a wiring problem. The vacuum has plugged due to improper airflow or an inefficient burn process.

Intelli-Choice Control Board recognizes system is operating properly in the BURN CYCLE. The system will stay in the

BURN CYCLE until some outside force interrupts the system, i.e., fuel hopper empties, power interruption, system turned off by operator, thermostat does not call for heat, etc.

Intelli-Choice Control Board recognizes a vacuum is not present

AND an overheat condition of the stove, if the stove is hot. If the stove is cool, then all snap disks are bad OR there is a wiring problem. If the stove has been operating properly, it is most likely an overheat condition due to failure of an exhaust or room air fan. The vacuum has become plugged due to inefficient burn.

Intelli-Choice Control Board recognizes an overheat condition of the stove, if the stove is hot. If the stove is cool, then all snap disks are bad OR there is a wiring problem. If the stove has been operating properly, it is most likely an overheat condition due to failure of an exhaust or room air fan.

Intelli-Choice Control Board recognizes a startup problem. The igniter did not create a fire within the specified time

(approximately 10) and has timed out. The igniter system or combustion airflow should be checked and corrected.

Intelli-Choice Control Board has been put into the prime mode.

The system is “loading” the auger full of fuel. Once pellets or corn start dropping into the burn pot, the system should be turned off and then startup procedures can be initiated.

NOTE

: The above code definitions have been

reverse highlighted

for all normal operating codes. Any Code Definition in the table that is not

reverse highlighted

is considered an abnormal condition and should be corrected before the stove is allowed to continue to operate

.

24

STOVE ELECTRICAL DIAGRAM

FIGURE 8 provides the Harvester electrical schematic of the components and sensors that are either operated or monitored by the Country Flame control board. Please refer to this diagram when necessary.

\

FIGURE 8: ELECTRICAL DIAGRAM

25

STOVE SPECIFICATIONS

TABLE 2 shows the physical dimensions of the Crossfire product.

CROSSFIRE

DIMENSIONS

(IN INCHES)

STOVE HEIGHT (At Front)

STOVE DEPTH (From Shroud)

STOVE WIDTH (Rear)

STOVE WIDTH (At Shroud Mount)

STOVE WEIGHT (empty)

SHROUD WIDTH, (standard)

SHROUD HEIGHT (standard)

SHROUD WIDTH, (oversized)

SHROUD HEIGHT (oversized)

22.5“

14.0“

26.0“

25.5“

220 pounds

42.0”

30.0”

48.0”

32.5”

TABLE 2: CROSSFIRE, CF-O4 SPECIFICATIONS

ELECTRICAL REQUIREMENTS

The Crossfire Model CF-04 requires a code compliant grounded 120 volt, 15 ampere, and 60 hertz electrical outlet. The Crossfire utilizes only a fraction of the 15 amperes rating of a code compliant outlet but it is strongly recommended that a dedicated circuit (versus a branch electrical circuit) be provided for the stove to ensure no interference from other electrical appliances.

GOLD DOOR CARE

All Crossfire plated doors and trim (gold or nickel) should be wiped down BEFORE THE FIRST FIRE to prevent potential permanent damage to occur to plating. For general cleaning, use a dry cloth and wipe the plated surface to ensure the luster and beauty lasts a lifetime. Always use an approved glass cleaner (i.e.

Windex, Glass Plus) and a lint free soft cloth to polish the doorframe. DO NOT use abrasives, like steel wool, brass polish, or cleaners, like Comet. Improper cleaners can permanently scratch the finish. A damaged door can be returned to Country Flame for refinishing but repair is expensive. Proper care of the

Crossfire plated door and other plated trim will ensure these parts will survive a lifetime of use. A painted

Crossfire door requires no specific care.

OPTIONAL FEATURES

There is an ever growing list of options for Country Flame stove products, including the Crossfire. Contact an authorized Country Flame dealer for more information.

OPTIONAL THERMOSTAT OPERATION

A thermostat option is available for the Crossfire.

CROSSFIRE IS COLD

• See start-up procedure.

CROSSFIRE IS HOT

• If the stove is set to a heat setting greater than 1 when the thermostat calls for heat, the Intelli-Choice

Control Board will remember this setting and return to this setting any time heat is called for by the thermostat.

• If the heat level is equal to 1 when the thermostat calls for heat the Intelli-Choice Control Board will use this setting whether heat is called for or not.

• The stove will operate at the selected Heat Level until such time as the thermostat stops calling for heat. The Intelli-Choice Control Board will then return the stove back to heat level 1. The last heat level programmed by the operator will be remembered by the software for use as the next Thermostat

Heat Level when heat is again called for by the thermostat.

26

CHANGE HEAT LEVEL (thermostat active)

• When the homeowner changes the control board heat level setting, while the thermostat is active

(calling for heat,) the new setting becomes the new thermostat (call for heat) setting. The stove will move to that heat setting anytime the thermostat calls for heat. Otherwise, when the thermostat no longer calls for heat, the control board sets the stove to Heat #1.

• If the operator changes the heat level to 1 while the thermostat is calling for heat, it will become the new Thermostat Heat Level. But because this is the same setting as when the thermostat stops calling for heat, the operator will get no indication that the thermostat is in control of the stove.

CHANGE HEAT LEVEL (thermostat inactive)

• If the operator makes a change to the heat level while the stove is inactive, the stove will move to that level. The next time the thermostat calls for heat, the most recently programmed heat level will become the Thermostat Heat Level and the stove will operate at that point until the thermostat no longer calls for heat.

FIGURE 10: CROSSFIRE COMBUSTION FRESH AIR CONTROL

COMBUSTION FRESH AIR CONTROL

Combustion fresh air can be controlled on the Crossfire. This control assists in optimizing the burn rate of the fuel. All air entering the firebox is controlled with this fresh air control system. A control lever as shown in figure 10 above, opens and close’s the inlet damper. This air control should allow the homeowner to adjust for any variation in fuel to ensure an efficient burn. If the fresh air is connected to a pipe leading outside the house, the fresh air control should be kept in the closed condition to minimize air infiltration into the home when the Crossfire stove is not in use.

27

INSTALLATION

INSTALLATION PREPARATION

Country Flame strongly recommends the Crossfire be installed by a certified professional. Improper installation will create long-term operational and maintenance problems that will plague the homeowner until corrected. The first step is to ensure all necessary parts are available to complete a proper installation. Country Flame recommends a homeowner purchase the Crossfire from an authorized dealer who both knows and supports Country Flame product. If purchased from Country Flame, a

Crossfire shroud will need to be ordered based on the size of the fireplace opening and the trim package desired. A flue system can be ordered from Country Flame or bought from many different “big box” store outlets. Follow this manuals requirement in purchasing flue pipe and the flue pipe manufacturer’s instructions and conform to all local codes. The following checklist is provided to assist in ensuring a home is prepared for installation: a) b) c) d)

Country Flame Crossfire biomass stove.

Country Flame or custom shroud to frame Crossfire stove around hearth.

Flue pipe per site and local code requirements.

Code approved power outlet @ 120 Volt, 15 amperes (dedicated circuit recommended). e) f)

No extension cords between stove and electrical outlet.

Clean and dry certified pellet fuel.

The Crossfire should be installed into a masonry fireplace or zero clearance fireplace on a level or slightly sloping floor angle as measured from the front to the rear of the hearth opening. If the Crossfire is sloped forward to ANY degree, bridging of pellet fuel may occur inside the hopper. Bridging will starve the fire and cause a flame out due to lack of fuel. Ensure the fireplace hearth is flat or sloping to the rear of the firebox.

If an exhaust flue system is run over ten feet, Country Flame requires its pellet stove products to be connected to a four-inch versus a three-inch flue pipe to vent the stove. Country Flame has designed a built-in clean out “T” on the back of the stove to assist in annual maintenance. This clean out T is bolted to the floor and is designed so that the exhaust flue connects to the stove on top of this clean out

T. The Crossfire is designed for a 4 inch stainless steel flue pipe to be connected to this clean out T and will line the existing chimney. Insulating the flue liner is strongly recommended by Country Flame.

Should a 3 inch stainless steel flue lined is to be used in a Crossfire installation; a 4 inch to 3 inch adapter will be required. Terminate the flue at the top of the chimney with a weather plate, proper termination cap, and support the flue liner weight. Once proper electrical power is connected to the

Crossfire and an appropriate shroud is used to finish out the installation, the Crossfire install is complete.

STOVE CLEARANCES

The Crossfire minimum clearances must be maintained during installation. Failure to maintain proper clearances can create a hazardous environment that will lead to a house fire or endanger the occupants.

A stove that is installed correctly and maintained properly will minimize operating costs. Country

Flame recommends the use of a Hearth Industry Professional that is certified to install pellet-burning products. Check with the local dealer or contact Country Flame if there is any question about the installation, the installer, or the product being installed. Maintain the minimum clearances to combustibles shown in TABLE 3. Follow all chimney manufacturers’ installation instructions when installing a chimney system. Inevitably there will be differences between the chimney manufacturer and Country Flame’s stove clearances. Always utilize the largest clearance listed. Contact Country

Flame or one of its local authorized dealers to resolve any questions. The Crossfire was designed for

28

installation into an approved masonry or zero clearance fireplaces, the use of single or double-wall flue pipe will not affect the clearance distance from the unit to any combustible materials.

DEFINED MINIMUM DISTANCES

TO COMBUSTIBLES

CLEARANCE

A. UNIT TO SIDEWALL

B. UNIT TO SIDE TRIM

C. UNIT TOP TO TOP TRIM

D. UNIT TOP TO MANTLE

E. HEARTH FLOOR TO MANTLE

F. NONCOMBUSTIBLE FLOOR PROTECTION, front

G. NONCOMBUSTIBLE FLOOR PROTECTION, sides

7”

7”

9.25”

9.25

32”

6”

6”

TABLE 3: REQUIRED MINIMUM CLEARANCES

SHROUD INSTALLATION

FIGURE 11 shows the Country Flame shroud, with standard black trim, mounted on the Crossfire.

New home construction normally will not require a shroud kit because the fireplace opening can be finished out to exact Crossfire dimensions. For pre-existing installation, a shroud kit is recommended.

Country Flame offers three variations of shroud kit a) standard, b) oversize, and c) custom shroud. The

Crossfire is designed to accept the shroud to simplify installation. Each Crossfire shroud comes with installation instructions and required hardware. Optional color trim is available. Contact an authorized dealer for further description.

FIGURE 11: CROSSFIRE SHROUD

29

CHIMNEY

It is extremely important that a Crossfire stove be vented into a non defective, clean, and properly lined chimney. The chimney system must conform to all local building codes. In the event a masonry chimney is not used, a listed factory-built chimney suitable for use with solid fuels should be used.

This listed factory-built chimney system must conform to ULC-S629 (Canada) or UL 103HT (United

States.) Any chimney can and should be lined with a 3 inch (under 10 feet) or 4 inch (over 10 feet) stainless steel flue liner attached directly to the outlet pipe of the Crossfire stove. DO NOT

CONNECT ANY CROSSFIRE APPLIANCE TO A CHIMNEY FLUE SERVING ANOTHER

APPLIANCE.

FIGURE 12 and FIGURE 13 illustrate both masonry and zero clearance chimney connections for both masonry and factory-built chimney applications. If installations require something different than one of these illustrated methodologies, please contact a local code official and a professional installer to ensure the proposed installation is code approved. All flue joints require 3 screws to secure the joints.

FIGURE 12: MASONRY CHIMNEY FIGURE 13: ZERO CLEARANCE

FACTORY-BUILT CHIMNEY

For any factory-built chimney installation, in conjunction with a Crossfire insert, the homeowner should refer to the chimney manufacturer’s instructions. It is important that in addition to manufacturer’s instructions, the homeowner must follow all national and local codes during the installation process.

The Crossfire insert clearances to combustible materials, listed in TABLE 3 must be maintained. If local code allows, these distances can be reduced when acceptable shielding is provided. Consult a local code authority and professional installer to ensure that a specific installation meets proper code.

MASONRY BUILT CHIMNEY

Before connecting the Crossfire to a chimney, be sure to have the chimney inspected by a chimney professional and cleaned, if necessary. The chimney should have a liner that is free from cracks, deterioration, softening, or other damage that may prevent it from containing the byproducts of

30

combustion. In all cases, the flue must be relined with a listed liner system, such as HomeSaver

Chimney Liner. If your masonry built chimney contains oversized flue tiles it must be relined to ensure proper draft. This means that a new, properly sized liner system must be installed before connection to the Crossfire stove is completed. Again, for 10 feet or less a 3 inch stainless steel liner can be used with the Crossfire. For lengths greater than 10 feet, a 4 inch stainless steel liner is to be used. It is also strongly recommended that these stainless steel liners be fully wrapped in insulation.

This insulation will limit moisture buildup and ensure better performance of the Crossfire stove.

Country Flame strongly recommends the use of smoke and carbon monoxide detectors when installing the Crossfire. Always refer to local codes and a professional installer to ensure proper installation.

FLOOR PROTECTION REQUIREMENTS

1. A Country Flame Crossfire insert REQUIRES A NON-COMBUSTABLE FLOOR

SURFACE Refer to TABLE 3 on page 27 of this manual to ensure all clearances to combustible material are met during the installation of a Crossfire stove. Ensure that any noncombustible floor protection equals or exceeds R = 1.5 or greater. Refer to TABLE 3 for floor protector clearance requirements.

2. If a floor protector, different from the tested floor protector, is to be used, it must meet or exceed the requirements of the listed R-value of the tested floor protector. To convert alternate floor protectors to their respective R value use the following procedures: a. Convert floor material specification to R-value. i. R-value is given – no conversion is required. ii. k-factor is given with required thickness (T) in inches: R = (1/k) x T. iii. C-factor given: R = 1/C. b. Determine the R-value of the proposed alternate floor protector. i. Use the formulas provided in STEP 2a to convert values not expressed as “R.” ii. For multiple layers of material, add each R-value of each layer to determine the materials overall R-Value. c. If the overall R-value of the alternate material is greater than the R-value tested material defined in STEP 1, then the alternate floor protection is acceptable. d. EXAMPLE: i. The tested material was ¾-inch thick with a k-factor of 0.84. ii. The R-value of the tested material was R = (1/0.84) x 3/4 = 0.893. iii. The proposed alternative floor protector is 4-inch brick material with a C-factor of 1.25 over 1/8-inch mineral board with k-factor of .29. iv. The 4-inch brick material has a value of R brick v. The mineral board has a value of R mnbrd vi. Total R brick

+ R mnbrd

= 0.80 + 0.431 = 1.231.

= (1/1.25) = 0.80.

= 1/0.29 x 0.125 = 0.431 vii. Since the total R-value of the alternate example floor protector (R=1.231) is greater than the tested example floor protector (R=0.893), the alternate is acceptable.

3. Listed Floor Protector Definitions: a. Thermal Conductance = C = Btu/(hr)(ft

2

)(

O

F) = W/(m

2

)(

O

K) b. Thermal Conductivity = k = (Btu)(inch)/(hr)(ft

2

)(

O

F) = W/(m)(

O

K) = Btu/(hr)(ft)(

O

F) c. Thermal Resistance = R = (ft

2

)(hr)(

O

F)/Btu = (m

2

)(

O

K)/W

4. Install in accordance with 24 CFR, Part 3280 (HUD).

5. WARNING: Crossfire insert stoves must always be placed on a listed floor protector if the existing floor where the stove is to be placed is made of any combustible material. Never allow

31

carpet to come in contact with any part of the Crossfire insert. Maintain clearances to combustibles as specified in TABLE 3, page 29 of this manual.

OUTSIDE AIR COMBUSTION

It is imperative that the installer and homeowner ensures that a minimum of at least eight square inches

(fifty square centimeters) of outside air be admitted to the hearth room or directly to the Crossfire. If installation allows, the Crossfire fresh air intake should be connected through an exterior wall.

Provision for outside combustion air may be necessary to ensure that fuel-burning appliances do not discharge byproducts of combustion into the house. Guidelines to determine the need for additional combustion air may not be adequate for every situation. If in doubt, it is advisable to provide outside air.

Outside combustion air may be required if:

1. The Crossfire does not draw steadily, smoke rollout occurs, fuel burns poorly, or back-drafts occur whether or not combustion is present.

2. Existing fuel-fired equipment in the house, such as fireplaces or other heating appliances smell, do not operate properly, suffer smoke rollout when opened, or back-draft occurs whether or not combustion is present.

3. The home is equipped with a well-sealed vapor barrier and tight fitting windows or has any powered devices that exhaust house air.

4. There is excessive condensation on home windows in the winter.

5. A ventilation system is installed in the house.

If any of these or other indicators suggests that infiltration air is inadequate, additional combustion air should be provided from the outdoors to the Crossfire appliance. Outside combustion air can be provided to the appliance by the following means:

1. Direct connection: appliances can only use direct connection of outside combustion air if they are certified for this type installation. Follow the Crossfire instructions for direct connection of outside combustion air.

2. Indirect connection: for appliances not certified for direct connection of outside combustion air, outside air can be ducted to within twelve inches of the appliance.

3. Mechanical ventilation: if the house has a ventilation system (air change or heat recovery): a. The ventilation system may be able to provide sufficient combustion make-up air for the Crossfire appliance. b. The homeowner should be informed that the ventilation system might need to be rebalanced by a ventilation technician after installation of the Crossfire stove.

32

MOBILE HOME INSTALLATION

WARNING:

DO NOT INSTALL A COUNTRY FLAME CROSSFIRE STOVE IN ANY MOBILE

HOME SLEEPING ROOM.

WARNING:

THE STRUCTURAL INTEGRITY OF THE FLOOR, WALL, CEILING AND ROOF

MUST BE MAINTAINED DURING THE INSTALLATION OF A COUNTRY

FLAME CROSSFIRE STOVE IN A MOBILE HOME.

WARNING:

A CROSSFIRE STOVE INSTALLED IN A MOBILE HOME MUST BE COMPLETED

IN ACCORDANCE WITH 24 CFR, PART 3280 (HUD).

WARNING:

A CROSSFIRE STOVE MUST BE PERMANENTLY BOLTED TO THE FLOOR OF

THE MOBILE HOME.

WARNING:

A CROSSFIRE STOVE MUST BE ELECTRICALLY GROUNDED TO THE STEEL

FRAME OF A MOBILE HOME.

MOBILE HOME RULES

1. Install only a HUD-approved laboratory tested stove in a mobile home. If the metal tag permanently affixed to a pellet burning stove does not specifically state; “mobile home approved to HUD Standard

UM-84,” do not install the product in a mobile home. The Crossfire Model CF-04 is approved for use in mobile homes. Install all Crossfire stoves in accordance with 24 CFR, part 3280 (HUD).

2. A permanent (hard line) combustion fresh air duct system must be installed and connected from the outside of the mobile home directly to the combustion air inlet on a Crossfire stove.

3. A Crossfire stove must have a listed prefabricated chimney system installed in the mobile home. This chimney system must be properly connected and installed directly from the stove through the roof of the mobile home using only one manufacturer’s chimney products. Follow the chimney manufacturer’s installation instructions to the letter.

4. All mobile home stove installations or stove replacements require a permit to be obtained from the local code department and at least a final inspection before operation of the stove is authorized. Use only licensed contractors to perform the installation work. Further, an insurance representative should provide an approval document stating that the installation and inspection are in accordance with industry standards and therefore covered by the homeowner’s insurance policy.

MOBILE HOME CLEARANCES

1. Clearance is defined as the open space distance between any part of the stove or its flue connector and any combustible material, including but not limited to: walls, ceilings, trim moldings, furniture, word storage containers, or any other combustible item. Refer to the stove clearance section of this manual or the certification tag on a stove for minimum clearances that must be maintained during installation of a stove into a mobile home.

2. Use of an approved thermal barrier may allow for the reduction of no barrier minimum stove clearances. Remember that a wall (wood studs covered with sheetrock, even if that wall is covered with brick) is still considered combustible. Functional thermal barriers are made of hearth pads consisting of two ¼” sheets of mineral board or 24-guage sheet metal spaced 1” from the combustible wall, with approved spacers that provide additional protection to the combustible wall. Refer to a hearth pad manufacturer’s instructions or the National Fire Protection Association Publication 211.

33

Do not violate minimum clearances with approved thermal barriers. Manville’s CERAFORM 126 is an example of an approved insulated wall protector. This product has a K equal to .27 and is a halfinch thick. Total thermal resistance should exceed 1.5 for any material used to ensure proper thermal protection of a combustible wall.

MOBILE HOME STOVE ATTACHMENT

1. Install combustion air to the back of the Crossfire in all mobile home applications. The other end of the combustion air tube is to be installed through the mobile home floor or a wall. Ensure that snow or other material cannot prevent fresh air from entering the duct located outside the mobile home.

2. The Crossfire must be secured to the floor of the mobile home, as shown in FIGURE 14 and must be properly grounded to the steel frame of a mobile home.

3. Install a mesh screen or an approved fresh air cap on the outside of the mobile home combustion air tube. This cap will keep foreign material, birds, or small animals out of the fresh air system. Do not use mesh screen from windows as it has too small a hole.

4. If operation of the Crossfire stove causes room air starvation, dangerous fumes can be sucked into the mobile home from other vented appliances. WARNING: DO NOT INSTALL ANY CROSSFIRE

PELLET BURNING STOVE IN A SLEEPING ROOM. Air starvation usually occurs: (a) because the combustion air intake is blocked, (b) because the stove door is left open or does not seal properly, or (c) due to strong exhaust fans being operated inside the mobile home. Always ensure that fresh air intake systems remain unblocked and ensure free fresh airflow. Contact your local

Country Flame dealer for annual inspections.

FIGURE 14: MOBILE HOME PEDESTAL INSTALLATION

MOBILE HOME FLOOR PROTECTION

1. A mobile home floor must be protected against stray sparks, radiant heat build up, or from damage during general use.

2. This floor protection must meet certain minimum requirements as a thermal barrier. Calculations are provided in this manual for determining if a floor protector meets minimum requirements for a mobile home installation.

34

3. At no time should a floor protector be placed on top of carpeting. Carpeting must be removed and the floor protection should sit directly on the uncarpeted portion of the mobile home floor.

Floor protection should extend to the front, sides, back, and under the chimney connector as defined for a specific model listed in this manual. In the event there are floor protection questions, contact Country Flame or one of its local authorized dealers for assistance.

MOBILE HOME CHIMNEY AND DUCTS

1. ALL PELLET VENTING systems should be composed of listed TYPE L or TYPE PL, factorybuilt flue pipe and components assembled in accordance with the manufacture’s instructions for conveying flue gases from a listed pellet fuel-burning appliance to the outside atmosphere.

Although a listed component does not guarantee a chimney fire will not occur, it is as close to ideal as industry standards provide today. Mobile home pellet stove and flue pipe restrictions are that: (a) regular thin walled stovepipe is not permitted, (b) roof systems cannot be weakened when installing a chimney or flue system, (c) a chimney cap and spark arrester are mandatory, and (d) the chimney must be strong enough to withstand normal area wind velocities.

2. There are many chimney manufacturers providing excellent products that meet government listing requirements. From single wall, to double wall, to triple wall chimney components, each type and brand meets many various application criteria. Further, each chimney manufacturer provides excellent written instructions on HOW TO install a chimney system. This information should aid the homeowner in ensuring a certified professional completes the job properly. If there are questions, contact Country Flame or a local authorized dealer. If additional information is required, a search of the internet will provide plenty of valuable information. An example of an informative and excellent chimney product manufacturer’s website is www.duravent.com

.

3. A complete chimney system should include a HUD approved spark arresting chimney cap, a storm collar, a roof flashing, an attic radiation shield (if needed), a chimney support box, a ceiling finish collar, and other parts required by site specific conditions. There will be clearance differences presented in both the stove and chimney manufacturers’ product literature.

ALWAYS use the larger clearance requirement when installing a pellet burning stove system into a mobile home.

4. A mobile home chimney system should serve only one pellet burning stove. The chimney system must extend at least 3 feet above the highest point on the roofline where it passes through the roof. The chimney system should be at least 2 feet higher than any part of a roof or building within a 10-foot clearance around the chimney. The minimum chimney vertical height is 8 feet and the maximum chimney vertical height is 30 feet as measured from the top of a specific

Crossfire model stove to the chimney flue exit. REMEMBER: The structural integrity of a mobile home wall and roof must be maintained during installation of a Crossfire stove. Country

Flame strongly discourages the removal or cutting of roof trusses or other structural components of a mobile home in order to install a stove. Consult local code.

5. To comply with over-the-road height limitations and to protect the chimney system and roof from damage remove all above roof chimney parts during transport of a motor home. Use only noncombustible material to seal all chimney system joints to prevent cold air leakage into a mobile home. Refer to local codes or consult with an authorized local Country Flame dealer to obtain the name of approved noncombustible sealants.

6. Many chimney manufacturers provide mobile home chimney kits. Mobile home chimney kits are not all-inclusive. A homeowner should consult with a certified professional. Additional chimney parts will be required to handle variations in local codes, site-specific mobile home issues, ceiling

35

height, ceiling slope, roof pitch, attic insulation, attic height, and surrounding objects. Use a certified professional to install a flue gas pellet venting system. Do not deviate from the pellet flue manufacturer’s installation instructions. Contact Country Flame or a local authorized dealer to resolve any questions or installation procedures. TABLE 4 shows the required components needed for a typical pellet flue pipe mobile home installation. Contact Dura-Vent or other authorized flue pipe dealers for the latest specifications and costs for mobile home pellet stove flue pipe parts or for a mobile home flue pipe kit from an authorized chimney dealer.

TABLE 4: MOBILE HOME (minimum) CHIMNEY SYSTEM REQUIRED PARTS

PART NUMBER

3180

3149

3151 (ALTERNATE)

DESCRIPTION

VERTICAL CHIMNEY CAP

0/12 – 6/12 ADJUSTABLE ROOF FLASHING

ROOF FLASHING, Flat (versus 3149)

QTY

1

1

1

3142

3141 (ALTERNATE)

3160B

CEILING SUPPORT BOX, Fire Stop Spacer

CATHEDRAL CEILING SUPPORT BOX, (versus 3142)

5 FOOT CHIMNEY SECTION

3179 STOVE PIPE ADAPTER (if needed)

CERAFORM 126 WALL PROTECTION ( IF REQUIRED)

3145B 45

0

ELBOW (if needed)

1

1

2

1

1

1

1

NOTE: The information provided in TABLE 4 and detailed in FIGURE 15 are for informational purposes. These pellet flue pipe system parts may or may not be needed depending on site specific conditions found in the specific mobile home application. Consult a certified professional and insure that any installation meets all federal, state, and local building codes. Failure to follow the flue pipe manufacturer’s installation instructions will void Country Flame’s product warranty and can have an adverse impact on the homeowner’s insurance policy. Contact Country Flame or one of its local authorized dealers to resolve any questions about installation or parts usage.

36

FIGURE 15: MOBILE HOME CHIMNEY INSTALLATION

37

MAINTENANCE REQUIREMENTS

GENERAL REQUIREMENTS

The Crossfire Model CF-04 has minimal maintenance requirements; however, failure to perform cleaning or maintenance items will lead to degraded performance and potential safety hazards for both the home and its occupants. The Crossfire stove should not be operated routinely without thorough monthly cleaning (or more often) depending on frequency of use.

The three most common maintenance chores will be: a) b) c)

Refilling the hopper with fuel as needed.

Cleaning the firebox and glass as required, satisfying the customer.

Emptying firebox ash to ensure ash does not interfere with proper operation.

STOVE DOOR INSTALLATION

. If the door is removed for any reason, care must be taken in reinstalling the door to ensure proper alignment and fit. Setting the door is quite simple. Ensure the door is in the fully open position. Once done, align the female portion of the door hinge with the male portion of the stove hinge. Gently lower the door hinges over the stove hinge pin. Once the door hinges have been set, the door can be closed to check for proper fit. The

Crossfire door installation should now be complete. To remove the door, simply lift up on the door from the stove hinges. Store the door in a secure place. If the door is left sitting, ensure that the door cannot fall and injure someone or damage the door or glass. The Crossfire door has been adjusted at the factory. If the door fit is not satisfactory, the homeowner can adjust the door using the hinge screws, refer to FIGURE 16.

FIGURE 16: DOOR ALIGNMENT POINTS

38

STOVE DOOR ADJUSTMENT

The Crossfire door may require fine adjustment due to variations in the door, the gasket material, due to hinge wear, or to maintain a center-aligned appearance. The Crossfire door needs to remain airtight to ensure proper firebox operation. The Crossfire door can be adjusted up or down and left or right with the adjustable hinge pins as shown in FIGURE 16.

The door gasket can also be adjusted to improve on the airtight fit. To adjust the gasket tightness, simply rotate the door latch clockwise (tighten) or counterclockwise (loosen) one complete revolution or as necessary to adjust the gasket seal. A good test to evaluate proper door gasket seal is to lay a dollar bill against the stove frame and then close and latch the door. If gently tugging on the dollar bill does not dislodge it from the door, the seal is appropriate. In the event that a proper door gasket seal cannot be obtained, it may be time to replace the door gasket.

STOVE DOOR GLASS CLEANING

The Crossfire stove is designed with an air wash system that assists in keeping the door glass clean. If the

Crossfire stove is operated continuously on low heat setting, the door glass will get dirty quicker than when a medium to high fire is fueling the firebox. If the operator wants the door glass to remain clean for the longest period of time, a high temperature fire must be maintained. CAUTION: Do not clean hot glass. If glass requires cleaning, use an authorized stove glass cleaner on a cool glass. Contact Country Flame or one of its local authorized dealers to obtain a suitable glass cleaner. Regular household glass cleaners are not effective in cleaning creosote and other residue from the glass. DO NOT use abrasives such as steel wool or powder abrasives as they will permanently damage the glass. Once the glass has been scratched, complete replacement of the glass is required. Use only approved 1400°F high temperature stove ceramic glass to replace any cracked or broken glass.

FIGURE 17: DOOR GLASS REPLACEMENT

GLASS REPLACEMENT

The glass used in the Crossfire stove is a 1400° F high temperature ceramic glass. If the glass should crack or break for any reason, it must be replaced with an equal or better grade ceramic glass. The use of tempered glass or ordinary glass IS NOT AUTHORIZED and its use is hazardous. Crossfire replacement glass can be purchased direct from Country Flame or one of its authorized dealers. See FIGURE 17 for securing points for

39

the door glass. Removal of these glass retaining clips can be accomplished with household tools. Order the necessary replacement screws or glass clips when ordering glass to ensure worn parts are replaced.

GLASS-CERAMIC SPECIFICATIONS

Window Type

Glass-Ceramic, Kera Lite®

KERA LITE® glass-ceramic has a thermal endurance far exceeding that of normal tempered glass. KERA

LITE® is designed to operate at temperatures ranging from -400

0

F to +1400

0

F. Despite its superior thermal properties, KERA LITE® stove windows should be treated with care. This glass-ceramic can still be scratched or broken by mechanical abuse. When cleaning the window, use only non-caustic, non-abrasive cleaners. The Crossfire stove uses KERA LITE® glass-ceramic that is 0.197 inches thick +/- 0.008 inches.

Country Flame custom cuts each KERA LITE® glass at its factory to fit the Crossfire stove. If problems occur with glass or any replacement part is needed, contact Country Flame or a local authorized dealer for assistance in ordering the necessary parts.

CAUTION: Do not attempt to clean hot glass. Do not abuse, strike, slam shut, or operate the

Crossfire stove with any broken glass in the appliance.

GASKET REPLACEMENT

Remove the doors from the unit. Place the doors, face down on a protective surface to ensure no marring or scratching occurs during gasket replacement. To replace the Thermoglass

™ knitted rope and tape gasket, first remove all of the old material and gasket cement. Use a putty knife or other sharp instrument to assist in removal. Use caution to prevent injury when removing old material. It is important to ensure the doorframe area is totally clean before installing the new gasket cement and material. The gasket must fit tight against the door frame in order to ensure a proper airtight seal when the stove is being operated. Apply gasket cement to the gasket channel per instructions provided with the gasket kit. Once the cement has been properly applied, install the new gasket. Both gasket and gasket cement are available from your authorized Country Flame dealer. The following table defines the gasket material used in the Crossfire stove:

Gasket

Around glass

Doorframe

Length Quantity Dimensions

4.25 feet each 1 ¾” wide by 1/16” thick tape

5 feet each 1

3/8

” rope, high density

CROSSFIRE CLEANING

A Crossfire stove will require general cleaning, depending on frequency of use. During heavy use, daily cleaning of the firebox will be required and less frequently during light use. Allow the ash in the fire box to completely cool before removing the waste with an industry approved ash vacuum.

The stove should be professionally cleaned twice a season if heavy use (daily use) is expected. A certified chimney sweep will have the proper tools to make short work of semi-annual cleaning. Country Flame has designed the Crossfire to make semi-annual cleaning as simple as possible. In fact, Country Flame designed the Crossfire so that it does NOT require removal from the fireplace in order to be properly cleaned. The following figures show how to access the cleaning ports on the Crossfire. By understanding how to thoroughly clean your Crossfire, the operator can maintain the stove in tip-top shape to ensure proper combustion and high efficiency. If questions do arise, do not hesitate to contact your Country Flame Dealer for additional information.

40

In order to thoroughly clean the exhaust chamber, the Crossfire has two cleaning ports that provide access to the exhaust chamber. In order to gain access to these clean-out ports, the hearth plate must be removed from the front of the Crossfire. FIGURE 18 shows the hearth plate removed from the stove. There is one screw, located in the front center of the hearth plate that must be removed before the hearth plate can be lifted up and out of its location.

FIGURE 18: HEARTH PLATE REMOVAL

Note that the hearth plate has two tabs located on the left and right side. Once the screw has been removed from the center of the hearth plate, the hearth plate can b lifted (gently tapped) upward to remove it from its locked position

FIGURE 19: CLEAN-OUT PORT CAP REMOVAL

Once the hearth plate has been removed and set aside, along with the screw, the clean-out port caps can be removed. FIGURE 19 shows the cap locations behind the hearth plate. Once these caps are removed, the clean-out ports are now accessible. An industry approved ash vacuum can be used to remove any ash or debris that has accumulated in the exhaust chamber to be removed. Removal of this ash and debris will allow the stove to draw more air and thus burn with a greater efficiency. Failure to clean out these areas over a

41

period of use can lead to one or both exhaust chambers becoming blocked and thus causing the stove to burn inefficiently. FIGURE 20 shows an x-ray view into the clean-out port of the right side of the Crossfire. This right side clean-out port allows access to the right side exhaust chamber and underneath the exhaust fan itself.

There is no access to the chimney connector and clean out T box but a powerful vacuum will be able to suck considerable amount of ash from the chimney box thus assisting in proper maintenance of the stove.

FIGURE 20: X-RAY VIEW OF RIGHT SIDE CLEAN-OUT PORT

In the event a Crossfire system requires cleaning of the chimney to remove debris or ash, the Crossfire will require removal from its hearth installation in order to remove the chimney connector. This should not be necessary except under the most extreme operating conditions or in the event an animal has obtained entrance to the top of the chimney and built a nest inside the chimney. Again, the homeowner should contact a certified chimney sweep as they may have the equipment to clean the chimney from roof level thus eliminating the requirement to remove the Crossfire from its hearth installation.

Whatever time is spent maintaining and cleaning the Crossfire should be viewed as improving both the burn efficiency and the heat output of this product.

42

APPENDIX A: TROUBLESHOOTING GUIDE

Shut off the power to the unit and allow it to cool off when performing cleaning and maintenance.

Ignition

Fuel

Stove

Performance

Fire does not start.

Stove does not switch on

If Pellets contain a large amount of

(foreign matter) or sawdust

No fuel in Firepot

Check to see that igniter is glowing, reduce inlet air amount

The fire in the burnpot has not become hot enough

(approximately 10 minute delay)

You may want to screen/sift/Pellets before use if they contain a considerable amount of dust to reduce problems and maintenance.

Ensure that auger motor and auger flight is being turned. The auger may need to be primed if it has run empty or has become blocked. The stirring rod can be rotated by turning on the switch.

Hard build-up on the firepot base

Sand in the pellets may cause “clinkering” (hard brittle deposits found in the bottom of the firepot).

Screen your fuel to make sure that there is no sand or other foreign matter

If the pellets are not feeding into the firepot at the

Blockage in the auger.

If your stove is not working

You may be using the wrong fuel. Check that you

effectively

are using the correct fuel. Pellet wood fuel - with

8% or less moisture may be used. Your Country

Flame Dealer can advise on where to obtain fuel. D normal rate the auger may need to be cleaned. This may be due to fines or debris caught in the auger flight.

Stove not performing effectively

Stove not getting enough air

Stove Heat not adjusting

Restricted flue gas flow

Clean the Heat Exchanger System, as it may be clogged and blocked.

Check to ensure that the fresh air intake is clear and unobstructed.

Allow time between changing heat settings for the stove to adjust both fuel and air to the new heat setting.

Fly-ash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during start-up, shut down, or incorrect operation of the stove will lead to some soot formation which will collect in the exhaust venting system. The exhaust vent should be checked frequently and cleaned at least once a season.

Room Air Blower does not activate

Please contact your Country Flame Dealer as your stove may need maintenance

43

APPENDIX A: TROUBLESHOOTING GUIDE

(CONT’D)

Stirring Paddles do not turn

Fire Goes out

Stove Smokes

Cleaning

Glass

Doors

Ash Build Up

Fire goes due to ash build up

Build up in burn pot

Your Pellet Stove Smokes

Your Pellet Stove Smokes

Cleaning is messy or difficult

Glass Breaks

Luster on Gold Doors Fades

Doors are not airtight

The chain drive for the stirring paddles needs to be checked after the first 8 hours of operation as it can loosen. It is located by opening the left side door

(the one with the control panel). Inspect the tension of the chain. It should have approximately 1/2” play. If the chain is too loose, adjust the chain drive motor by loosening the 4 bolts securing it and sliding it back until there is proper play in the chain.

Re-tighten the bolts securely. This should be checked monthly or if you notice the stirring paddles not turning or binding.

The ash must be emptied as required, to prevent the build up of ash under the firepot blocking the air flow to the fire pot putting the fire out.

Do not leave viewing door open for more than 1-2 minutes or you may have to restart fire. Remove ash wearing proper gloves.

Your Firepot may need additional cleaning as extended burning.

The inlet air damper is open to far for the heat setting selected.

Check that the chimney is clean and free of soot and fly-ash build-up. Your stove exhaust system works with a negative combustion chamber pressure and a low positive chimney pressure. It is very important that the exhaust system be completely airtight and properly installed.

Clean the Heat Exchanger more frequently. This cleaning procedure should be done daily. If buildup is allowed to go unattended, cleanup will be much more difficult and the efficiency of your stove will be adversely affected.

Use care not to slam or strike door, this could result in glass breakage. If glass is broke or cracked, DO

NOT operate the stove. Repairs must be made.

Always use an approved glass cleaner (i.e. Windex,

Glass Plus) and a lint free soft cloth to polish the door frame. Do not use abrasives like steel wool, brass polish or adhesive cleaners like comet, as these will scratch the finish. If the Gold Doors are scratched they will have to be replaced or returned to Country Flame for refinishing. This is expensive and during this time you will not be able to use your stove.

Check door alignment for proper seal. Adjust door hinges as necessary to ensure a good airtight seal.

The doors may need new gasket material. Contact a local Country Flame dealer.

44

APPENDIX B: MAINTENANCE GUIDE

Shut off the power to the unit and allow it to cool off when performing cleaning and maintenance.

Regular Cleaning Removing and cleaning the Firepot

The firepot can be removed by removing 2 bolts.

Slide the keeper sleeve off of the stir rod gear shaft exposing the linkage. Rotate the stir rod until the

Removing “Clinkers”

slot is vertical. Now lift the firepot and the stirring rod out of the firepot holder. To replace, reverse the procedure. The stir rod can be rotated by operating the control board. See control board instructions.

A clinker or buildup on the bottom of the firepot may need to be removed for proper operation.

NOTE: For your Safety, only remove clinkers from stove when unit is cool. Wear gloves and eye protection.

Soot and Fly-ash Build Up The ash must be emptied every day (or as required). If the ash is not emptied regularly, ash will build up under the firepot and block proper

air flow to the fire pot putting the fire out. When the stove is cold, the firepot can be pulled out and removed for a thorough cleaning. Also, check the drop tube (where the fuel drops into the firepot) for blockage.

Remove ash when it is COOL. Use an industry approved ash vacuum for removing ash. Dump the ash into a fire safe covered container. The firepot may be lifted out (first remove bolts) and remove the stir rod. Dumb and clean the firepot as needed.

Vacuum the inside of the COOL unit and replace all parts BEFORE starting operation again.

Remove the “I” plugs located on each side of the firebox housing. Insert the vacuum hose into each of these COOL access ports. Completely vacuum and then replace “I” plugs. Air leaks will not allow the stove to burn properly.

Cleaning the Heat Exchanger.

A sliding plate fits over the fifteen tubes of the heat exchanger. The sliding plate is attached to a small rod protruding through the front of the stove just below the louver vent. Push the rod to the back of the exchanger and then pull forward to the front, several times. This will effectively remove ash and debris from the surface of the heat exchanger.

Performing this step often will ensure that cleaning is an easy task. This cleaning procedure should be done daily. If buildup is allowed to go unattended, cleanup will be much more difficult and the efficiency of your stove will be adversely affected.

CAUTION: Cleaning rod may be hot! Use a fireplace glove to protect your hand when using the cleaning rod to avoid getting burned!

45

General/Yearly

Maintenance

APPENDIX B: MAINTENANCE GUIDE

(CONT’D)

Cleaning the Glass

Cleaning the Gold Doors (optional feature)

To clean glass, use a mild non-abrasive cleaner when the stove and glass are COOL. Creosote builds up on glass quicker when a fire is burned at lower heat settings. DO NOT use abrasive cleaners on glass. (Glass may crack if subjected to cold liquid cleaners while the glass is still hot. Using cleaner on hot glass may also cause burns, emit fumes and the glass is more likely to stain.)

Doors should be wiped down regularly to ensure the luster of the door system lasts. Always use an approved glass cleaner (i.e. Windex, Glass Plus) and a lint free soft cloth to polish the door frame.

Do not use abrasives like steel wool, brass polish or adhesive cleaners like comet, as these will scratch the finish.

Periodically clean out the door air wash (a groove at the bottom of the door, with ash vac). This air wash directs air over the glass door to minimize soot buildup on the door.

Exhaust Venting System

After using your stove, you will observe small particles of fly-ash. The fly-ash will collect in the exhaust venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during start-up, shut down, or incorrect operation of the room heater will lead to some soot formation which will collect in the exhaust venting system.

The exhaust venting system should be inspected at least once every year to determine if cleaning is necessary.

Intakes When starting to use the stove at the beginning of the season, check to ensure that the fresh air intake is clear and unobstructed.

Oiling the Room Air and Exhaust

Blowers

If supplied with oil ports, the room air & exhaust motors will need to be oiled at least once per season with PROPER oil. Locate the oil ports on either the side or top of the units and add three drops of oil.

This simple step will greatly increase the life and serviceability of your unit.

Checking the tension on the Chain

Drive of the Stirring Paddles.

Inspecting the Door Gasket

Locate the chain drive by opening the left side door (control panel side). Chain tension should be approximately 1/2” play. If the chain is too loose, adjust the chain drive motor by loosening the 4 bolts securing it and sliding it back until there is proper play in the chain. Re-tighten the bolts. The chain should be checked monthly.

This is done by taking a 2” long strip of paper and shutting the door on it. Then pull the paper to test the gasket pressure. You should have to pull the paper from the door. Check all around the gasket. If the paper slides out easily or falls out, the gasket needs to be replaced. Country Flame recommends that both the door and glass gaskets be replaced at the same time.

46

APPENDIX B: MAINTENANCE GUIDE

(CONT’D)

Replacing the Door / Glass Gaskets

To replace the gaskets, remove the door by lifting it straight up off its hinge pins and laying it face down on a soft surface. Remove the door gasket (you may need to use pliers) and then remove the glass retaining clips and remove glass. Strip off old gasket around glass and clean glass well. Clean out old stove gasket material from gasket track. Once the door and glass are clean, apply gasket material to glass surface and return glass to door, securing with clips (Use care not to over-tighten). Then apply a generous bead of gasket cement into the track. Position the NEW gasket into track and gently press into door. Trim off any excess gasket and wipe away excess cement. Let the cement set

24 hours before placing door back on unit and using the unit. Gasket material and cement may be obtained from your dealer.

Replacing the Glass

Remove the door gasket (you may need to use pliers) and then remove the glass retaining clips and remove glass. Replacement glass should be 0.200”

(5mm) thick. Overall size of the glass is 16”

(405mm) wide by 11” (279mm) high, cut to an irregular shape to fit the door front. Your unit uses

Adjusting the Doors

Euro Kera

or a similar ceramic type high temp glass. Do not use any other than recommended glass type in this unit. Replacement glass may be obtained from your dealer. Clean out old stove gasket material from gasket track. Once the area is clean, apply gasket material to new glass surface and return glass to door, securing with clips (Use care not to over-tighten).

The doors of your Crossfire Stove may need some adjustment due to shipping vibrations, jarring during installation and extended use. It is important that the Crossfire door fit properly and remain airtight. Periodically check the alignment of the doors. To adjust the door, loosen the Allen bolts in the hinge and adjust the door accordingly. When completed, use a piece of paper between the door and the stove to ensure a proper seal. The paper should not pull out easily once the door is closed and latched.

47

APPENDIX C: TECHNICAL SPECIFICATIONS

Fuel Type: Hardwood Pellet Fuel

residential

Heat

Ash

5.9 lbs/hour maximum feed rate

Bulk Density: 40 lb./cubic ft. min

Moisture

Size: 1/4” to 3/8” diameter x 1.5” long max.

Fines: 1% max through 1/8 th

screen

Hopper Size:

Flue Size:

Flue Type:

Air Inlet:

55 pounds wood pellets

4” recommended. If less than 10 feet use of 3 inch pipe is approved.

PL double wall vent with stainless steel inner liner

3 inch by .15 inch walled steel pipe

Controls:

Intelli-Choice Control Board

Electrical:

120 Volts, 2.4 Amp, 60 Hz

Measurements:

CROSSFIRE HEIGHT (at front) 22.5”

DEPTH

CROSSFIRE

CROSSFIRE (at 25.5”

Weight :

Clearances:

TO

UNIT TO SIDE TRIM

UNIT TOP TO SIDE TRIM

UNIT TOP TO MANTLE

HEARTH

NONCOMBUSTIBLE FLOOR PROTECTION (front)

NONCOMBUSTIBLE FLOOR PROTECTION (sides)

Shroud Measurements:

SHROUD WIDTH (standard)

SHROUD HEIGHT (standard)

SHROUD WIDTH (oversized)

SHROUD HEIGHT (oversized)

*BTU/lb can vary depending on the moisture content of the pellet.

7”

7”

9.25”

9.25”

6”

6”

42.0”

30.0”

48.0”

32.5“

48

APPENDIX D: CROSSFIRE THEORY OF OPERATION

BURN PHASE

Multiple heat lights indicate the control panel burn phase. There are five lights (4 yellow and one red) used to indicate the relationship to the system’s heat settings. Pushing the control panel’s HEAT LEVEL switch will cause a heat light to cycle one level up from Heat 1 through Heat 5. Once the Heat 5 setting has been reached, if the HEAT LEVEL button is pushed again, the heat setting will cycle over again starting at Heat 1. The operator controls the heat output of the stove by utilizing Heat 1 through Heat 5 settings. Heat 1 setting provides the lowest heat output from the system and the longest time between refills of the fuel hopper. Heat 5 provides the maximum heat output from the system and the shortest time between refills of the fuel hopper.

Changing any heat setting up or down by one increment will cause a delayed (it takes time for both the fuel and air adjustments to impact the burn chamber) increase or decrease in the heat output of the system.

Changing any heat setting up or down by two or more increments will require an increased amount of time before the burn rate of the stove stabilizes.

The control system automatically adjusts to the requested heat settings without further intervention of the operator. NOTE: The control panel display immediately reflects the final heat setting requested by the operator regardless of how many incremental changes occur but the operator should remember that it takes

“time” for the stove to stabilize to the new heat setting.

COOL DOWN PHASE

Any time the system is switched off by holding the on/off switch for more than 3 seconds during normal stove operation, the control system will revert to the cool down phase. During the cool down phase the room, exhaust, and stir pot motors will be operated at high speed. The auger motor will cease to operate thereby ensuring minimal time for the burn phase to be extinguished. During the cool down phase the heat indicator lights will step down from red (5 th

light being on) to the first yellow light being on. This process will be repeated until such time as the control system senses that the stove has been properly cooled down. The auger and igniter lights are both off during the cool down phase.

49

APPENDIX D: THEORY OF OPERATION

(cont’d)

FAULT PHASE

The fault phase is indicated by all lights except the Country Flame logo light flashing on and off at a rapid pace. This event signifies that the control board has encountered an improperly operating system and requires intervention by either the operator or a properly trained service technician. In the event that the fault phase continues to flash lights, the operator should not try any repairs except those listed below without contacting their dealer or an authorized and properly trained service technician. Country Flame has made every effort to ensure the safety of the homeowner through proper use of this system. Any attempt to modify or circumvent the safety features of this product is prohibited by the manufacturer. In the event that the fault phase does not reset with the manufacturers recommended procedures, please contact your local authorized Country Flame service representative.

RESET CONDITION

Reset Condition #1 requires the system to properly proceed through cool down phase. By allowing cool down to occur the control panel will automatically shut off the system. In order for system shut off to occur all electronic controls must sense safe system temperatures. In the event “safe temperatures” are not sensed by the system, the control panel will continue to operate in the cool down phase until such time that safe temperatures are achieved or the operator intervenes. In order to perform a “hot restart” from the cool down phase, Reset

Condition #2 must be followed.

Reset Condition #2 assumes the operator has shut down the system and has now decided that a restart of the system is required. In order to perform a restart the operator must press and hold the up heat (red) arrow for a minimum of 15 seconds. This will return the system to startup phase. Please refer to startup phase for specifics. All procedures in the startup phase should be followed in order to ensure burn phase is properly achieved from the hot restart phase. NOTE: A HOT RESTART CAN ONLY BE ACHIEVED FROM A

COOL DOWN PHASE. In the event of a “fault phase” no hot restart can be initiated.

SYSTEM MAINTENANCE

There are two functions built into the control board that can be used to assist with maintenance or troubleshooting a system. These two control board functions are: a) Prime State

The Prime State is utilized upon installing a new stove or after a fuel bin (hopper) has been depleted of fuel.

The prime state can be entered by pressing and holding the on/off switch for a minimum of 15 seconds. By holding the on/off switch on for 15 seconds or more, the auger light (green) will be turned on and the heat lights will be sequenced from lowest to highest light being consecutively turned on to signify the auger being filled with fuel. This prime state will remain on for a maximum of 10 minutes or until the operator presses the on/off switch at which time the system will revert to the off state. The prime state is utilized only for filling the auger with fuel and can only be utilized from an “off state.”

The Stir Rod is controlled by the control board in one of two states: (a) when the system is shutdown, and (b) when the system is in the burn phase. The purpose of the stir rod is to mix the fuel and air to ensure a more efficient burn. During normal burn phase operation, the control board controls the motion of the stir rod. The operator can press both the blue (down) and red (up) heat arrows to turn the stir rod manually. This manual

50

movement facilitates removal of the stir rod for maintenance or for facilitating starting a fire by rotating the stir rod to enhance air flow during a fire’s startup.

In order to manually turn the stir arm, the up and down (red and blue) heat arrows must be simultaneously pressed while the control is in only the OFF PHASE or the STARTUP PHASE. As long as the up and down heat arrows are held in either the off or startup phase, the stir rod will rotate. Upon releasing either of these arrows, the stir rod rotation will stop turning. WARNING: Keep hands or loose clothing away from the stir pot.

51

APPENDIX E: COMBUSTION BASICS

An understanding of Combustion Basics will assist in resolving problems with a variety of fuels, changing product and environmental conditions during the operational life of a stove. Just exactly what are pellet or corn stove products suppose to do?

PROVIDE A CONVENIENT PLACE FOR STORAGE OF FUEL.

PROVIDE FOR CONTROLLING IGNITION, FUEL, COMBUSTION AIR

PROVIDE CONTROLLING HEAT FROM FIREBOX TO HEAT EXCHANGER.

CONTROL SYSTEM TEMPERATURE.

OPERATE SYSTEM EFFICIENTLY TO MINIMIZE WASTE.

ENSURE SAFETY FEATURES PROTECT USER AND SURROUNDING AREA.

Some standard terminology is required in order to discuss Combustion Basics. This terminology is reasonably standard throughout the different industries. The following terms should be part of a stove owner’s vocabulary and a basic understanding of these items is a must in maintaining a stove system:

Ash content: Refers to the non-combustible materials in a fuel, which reduce the heating value per unit of weight.

Carbon

Dioxide:

A heavy colorless gas that does not support combustion and dissolves in water to form carbonic acid.

Carbon

Monoxide:

A colorless, odorless, poisonous gas produced by incomplete combustion.

Incomplete burning of wood pellets will create this gas.

Combustion: Combustion refers to the rapid oxidation of fuel accompanied by the production of heat, or heat and light. Complete combustion of a fuel is possible only in the presence of an adequate supply of oxygen. Chemical reaction between a fuel and oxygen that usually takes place in air. Combustion is commonly referred to as burning.

Combustion

Air: The amount of air required inside the combustion chamber to create a burn.

Combustion air, for this manual, is defined as the amount of air required to ensure 100% burn of all fuel present in the burn chamber.

Combustion

Efficiency: Calculated measurement (in percent) of how well the heating equipment is converting a specific fuel into useable heat energy at a specific period of time in the operation of a heating system.

52

Combustion

Temperature: T he temperature required to ensure the release of flammable vapors. To sustain combustion, the heat evolved must maintain this temperature to provide a constant supply of vapors.

Excess Air: Any air added to the combustion process above the theoretical value defined as

100% efficiency. A combustion system operated exactly at the peak burn efficiency ratio has a high probability that some of the oxygen in the combustion air will not get paired up with the fuel. Adding excess air ensures that a percentage of additional air is available to ensure complete burn of all fuel.

Excess air reduces efficiency but ensures complete fuel burn as environmental variables change. In addition, a little excess air provides a cushion against the fuel-air ratio drifting over into the rich (excess fuel) range. With time, all combustion systems will tend to burn richer (that is more fuel than air.) The big enemy that creates a richer burn is dirt. Dirt is more likely to accumulate in the air system rather than in the fuel system. The combustion and makeup air fans, in addition to everything else within a stove, are giant vacuum cleaners, sweeping in any dust, dirt and vapors that happen by. In time, the systems air path becomes partially obstructed, starving the system for air and causing the fuel-air ratio to become rich. Excess air ensures that complete combustion can occur at all times regardless of changes in environmental variables.

Ignition

Temperature: The temperature at or above which a substance will combust.

Pyrolysis:

The second stage of ignition during which energy causes gas molecules given off by a heated solid fuel to vibrate and break into pieces.

Room Air: Air that is passed through a stove’s heat exchanger tubes which elevates the room air temperature and thereby delivers heat to a living space.

WOOD PELLET COMBUSTION BASICS

In a normal wood pellet combustion process, water is first boiled out of the pellet. Then volatile matter and fixed carbon matter are released in the combustion process and later burned to create heat. Any remaining product left behind in the burn process is defined as ash. FIGURE 18 illustrates the combustion process of wood.

Heat

Moisture

Solid Particles

Pyrolysis

Volatiles

Gas Phase Volatile

Oxidation

Carbon

Carbon Phase

Oxidation

FIGURE 18: WOOD PELLET COMBUSTION PROCESS

53

The obvious advantage of wood pellets over conventional chopped wood logs is the consistency of the fuel both from a size and moisture content. These palletized fuels burn more efficiently than their wood log counterparts. The heat generated in the burn process, once combustion is achieved, sustains the process as more fuel is added. As the gases burn, the pellet stove’s firebox temperature can achieve temperatures exceeding 1,000 o

Fahrenheit. The list below gives a sample of ignition temperatures for some of the carbon and volatile matters released when wood is burnt:

COMBUSTIBLE

Fixed Carbon

FORMULA

C

IGNITION TEMP (

O

F)

765

Hydrogen H

2

Volatiles

CH

4

C

2

C

C

2

6

H

H

6

H

4

6

1008 – 1018

1364

968 – 1166

Note that all ignition temperatures fall between 950 o

F through 1400 o

F for volatile matter. All visible flames emitted during a wood pellet fire come from the ignition of volatile matter. Good combustion occurs when the fuel vapors are thoroughly mixed with the combustion air. Mixing ensures that fuel molecules come in contact with oxygen fuel molecules. There must be an abundant amount of oxygen molecules available to react with the fuel molecules or an incomplete burn will occur. NOTE: The fuelair mixture must at all times exceed the combustion temperature as well as exceed the ignition temperature if a burn is to be sustained. There must be adequate time for the reaction to proceed to completion (complete burn.) It is commonly stated that good conditions for combustion are defined as the THREE T’s:

It requires turbulence in the fuel-air path to ensure that fuel and air molecules are thoroughly mixed to sustain the burn process. In addition, it takes a certain amount of temperature, defined as Ignition

Temperature to sustain the burn. It takes a certain combustion temperature to ensure volatile and carbon matter is released from the fuel that will then combine with the oxygen in the air further adding to the heat. This entire combustion process takes time to occur and is self-sustaining only if all conditions are met for the fuel being burnt.

Heat is obtained from a stove by the thermal radiation that occurs from the burning wood pellets.

Although a fairly complex phenomena to define, the heat radiated from the fire is a very strong function of the local (burn pot) temperature and the overall combustion temperature that is maintained within a stove’s burn chamber. A relatively minor combustion temperature increase in a pellet stove can produce a significant amount of increased heat output. NOTE: The reverse of the preceding statement is also true.

That is, if too much heat is pulled from the combustion chamber via the heat exchanger tubes, the combustion temperature can drop rapidly thus causing a “burn out.” Burn out occurs once the combustion chamber temperature drops below the critical “ignition temperatures” required of the different fuel components. Wood pellets, because of their low combustion temperature ensure an ample supply of volatile and carbon matters available for continued ignition. Once a burn chamber’s temperature begins to fall below critical ignition temperatures, the heat required to sustain the combustion temperature can also be lost and the fire will go out.

54

As a final note, the four basic stages of wood pellet burning are: a) Up to 212 o

F the pellet is boiling of the moisture. b) Near 575 o

F gasification of the solid wood pellet fuel occurs. The pellet will simply seem to disappear. Very little energy is released in these first two stages and external energy c) must be applied to sustain any combustion that is occurring.

Somewhere between 900 o

F and 1100 o

F the pellet fuel particles have combined with oxygen molecules and released the majority of the available energy. Some gases will still not have reached ignition temperature and at this critical stage, if too much heat is removed from the combustion chamber, no more fuel will be burnt. All remaining fuel will simply exhaust through the system as unburned material.

At temperatures around 1500 o

F the remaining gases and tars will burn off in the d) combustion chamber. This final combustion yields an additional 10 to 20% additional heat energy and gives a very clean final exhaust from the product.

Wood pellets, as compared to wood logs, enhance the amount of energy released during the burn cycle because of the uniformity of product, the reduced moisture content, and the variation in materials used to produce the wood pellet. These variations allow the turbulence in the burn system to ensure a better agitation of fuel with air and a more rapid and efficient burn.

The homeowner must be aware that as technology evolves, all stove manufacturers will strive to control more of the variables that might adversely affect the combustion process. In addition, stove manufacturers will strive to optimize the efficiency of the products burn process. It is the homeowner’s responsibility to understand not only the particular product but also how environmental issues beyond the control of both the manufacturer can affect a product’s burn process. This understanding will make trouble diagnosis less time consuming and more accurate for all parties involved in maintaining the product in a reliable manner to the satisfaction of our mutual customers.

55

APPENDIX F: REPLACEMENT PARTS

REPLACEMENT PARTS

Part Number Description Number per CROSSFIRE

PP-355

250

110

0

0

F OVER TEMPERATURE SENSOR

F EXHAUST/ROOM AIR SENSOR

1

1

NPS-1005-CF

Intelli-Choice

CONTROL BOARD 1

FRAME 1

DOOR GASKET 1

40-0000-05

56

APPENDIX F: REPLACEMENT PARTS (cont’d)

REPLACEMENT PARTS

Part Number Description Number per CROSSFIRE INSERT

PP-27 VACUUM HOSE 1

SIDE 2

SIDE 2

SIDE 2

SIDE 2

57

APPENDIX G: LABELS

REPLACEMENT LABELS

Part Number Description

PP-483 CAUTION LABEL

Number per CROSSFIRE INSERT

1

PP-484 CAUTION LABEL 1

58

APPENDIX G: LABELS (cont’d)

REPLACEMENT LABELS

Part Number Description

1

LABEL

Number per CROSSFIRE INSERT

59

advertisement