Bosch WTL5400 Installation Instructions Manual
Add to my manuals
12 Pages
Bosch WTA3500 is an electric vented dryer that effectively removes moisture and dries clothes quickly. Equipped with a 4-wire power supply cord, it operates on a 208/240-volt circuit, consuming 3,100 watts of power. This dryer boasts a large capacity, handling up to 88 pounds of laundry, making it suitable for families or individuals with high-volume drying needs.
advertisement
BOSCH
Installation Instruction.=°-
Models
WTA 3500
Electric Vented Dryer
WTL 5400
Electric Condensation
J \
Dryer
Quick Reference Index
INTRODUCTION
TOOLS NEEDED FOR INSTALL.
PARTS SUPPLIED FOR INSTALL.
PARTS NEEDED FOR INSTALL.
DRYER ELECTRICAL CORD
GROUNDING INSTRUCTIONS
ADDITIONAL GROUNDING
PROCEDURE
ELECTRICAL RECEPTACLE
VENTING
DUCTWORK
EXHAUST VENT HOOD
CONDENSATE DRAIN
TECHNICAL DATA
ELECTRICAL REQUIREMENTS
MINIMUM INSTALL. CLEARANCES
CHOOSING THE LOCATION
INSTALLATION
STEP 1, UNPACK THE DRYER
STEP 2, INSPECT THE DRYER
STEP 3, POSITION DRYER NEAR
INSTALLATION AREA
STEP 4, EXHAUST DUCT
STEP 5, CONDENSATE HOSE
CONNECTION
STEP 6, ELECTRICAL
STEP 7, POSITION AND LEVEL
THE DRYER
STEP 8, CONNECT DUCT SYSTEM
TO DRYER
STEP 9, FINAL CHECK LIST
4
4
4-5
5
5
5
5-6
6-7
7-8
8
9
9
3
3
3
3
2
2
2
2
2
2
3
INSTALLER:
Remove the door from all discarded appliances to avoid the danger of a
I IMPORTANT:
Before you begin read these instructions completely and carefully.
]
I
KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE.
(In case of change of ownership,
manual
should be conveyed with the dryer.)
Introduction
Read these installation instructions completely and carefully. They will save you time and effort and help to ensure optimum dryer performance. Be sure to observe all listed warnings and cautions.
These installation instructions are intended for use by qualified installers. In addition to these instructions the dryer shall be installed:
• In the United States, in accordance with the
National Electric Code, ANSI/NFPA70 ~ latest edition/State and Municipal codes and/or local codes.
• In Canada, in accordance with the Canadian
Electric Code C22.1 - latest edition/Provincial and Municipal codes and/or local codes.
Tools Needed for Installation
The following tools are needed far installation of this dryer:
• Box cutter
• Flat blade screwdriver
• #2 Phillips head screwdriver
• Duct tape
• Caulking gun and compound
• Level
• Safety goggles
• Gloves
Parts Supplied for Installation
Condensation water drain hose (WTL 5400 only)
Stacking kit
Parts Needed for Installation
(Model WTA 3500 Only!)
Four inch (approx. 100 mm) diameter metal exhaust
duct (rigid or flexible) of proper length and with
elbows and exhaust vent hood required to vent to
outdoors.
Dryer Electrical Cord
The Bosch dryer comes with a 4-wire power supply cord pre-installed. This cord fits a 4-wire receptacle as shown in the upper section of Figure 1.
If your receptacle is a 3-wire receptacle, as shown in the lower section of Figure 1, a 3-wire "Dryer Cord" must be purchased locally. The 4-wire cord must then be removed and the 3-wire cord installed in its place, as instructed in following section titled,
To Change Cord.
When purchasing a 3-wire power supply cord make sure the cord meets following requirements:
• U.L listed in the USA, CSA listed in Canada
• 240 volt rated (minimum)
• 30 ampere
• Type SRD or SRDT
• Five feet long (minimum)
Dryer shipped with cord to fit this type
4-wire receptacle.
4-wire receptacle
(14-30R)
3-wire receptacle
(10-30R)
If you have 3-wire receptacle, like this, a 3-wire dryer cord must be purchased locally.
Figure 1.
Grounding Instructions
This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for the electric current. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Improper connection of the equipmentgrounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in doubt as to whether the dryer is properly grounded.
Additional Grounding Procedure
Some local codes may require a separate ground. In such cases, the required accessory ground wire, clamp and screw must be purchased separately.
Never ground the dryer to plastic plumbing lines, gas lines or hot water pipes,
Electrical Receptacle
The receptacle for the dryer cord must be located so
that the power supply cord will be accessible when the dryer is in the installed position.
Venting
The WTA 3500, electric vented dryer, is intended to
be vented to the outdoors. To prevent build-up of
moisture and accumulation of lint indoors, as well as
to maintain maximum drying efficiency, it is
recommended that the Bosch WTA 3500 be vented to
the outdoors.
Ductwork
Four-inch (approx. 100 mm) diameter ducting should be used. Use either rigid metal or flexible metal ducting material. DO NOT use non-metal duct with this dryer.
Exhaust ducts should be as straight as possible.
Exhaust ducting longer than recommended Can extend drying time, can collect lint and may effect dryer performance.
Joints should be secured with duct tape. DO NOT use screws to secure joints as lint can collect on the screws. See Step 4, Exhaust
Duct, in following section titled INSTALLATION for recommended routing and duct length calculations.
Exhaust Vent Hood
The exhaust duct must end with an approved exhaust
vent hood with swing out damper(s). DO NOT use an
exhaust vent hood with magnetic latches. To avoid restriction of exhaust the outlet must be a minimum of
12 inches (30 cm) above ground level, or any other obstructing surface. See Figure 7.
Condensate Drain
The WTL 5400, electric condensation dryer, dries by
condensing the moisture from the dryer air and then
pumping this condensate out of the dryer.
The WTL 5400 must have its condensate hose connected to a suitable drain. See Step 5,
Condensate
Hose Connection, in the following
section titled INSTALLATION.
4
Technical Data
WTA 3500:88 Ibs. (40 kg)
W]'.
5400:99 Ibs. (45 kg)
Figure 2.
Electrical Requirements
The Bosch dryers should be CONNECTED TO AN
30A INDIVIDUAL BRANCH CIRCUIT. North American models have the following electrical rating:
Model
WrA 3500
WTL 5400
Volts
208/240
208/240
Hertz Amperes Watts
60
60
13
13
3,100
3,100
Check the rating plate on the dryer to make sure your machine has this rating.
Choosing the Location
The dryer should bot be installed:
•
in an area exposed to dripping water or outside weather conditions
• in an area where it (and imthe case of the WTA
3500, its exhaust duct) will come in contact with combustible materials, such as, curtains, drapes or paper.
• in areas where water may freeze
• in an area where gasoline or other flammables
are kept or stored (including gasoline powered vehicles or equipment).
Check local codes before choosing a location. Some
codes do not permit installationof a clothes dryer in a
garage, closet, mobile home or sleeping area. Your
local building inspector should be able to advise you of the codes in your area.
Minimum Installation Clearances
Sides
Top
Rear
Alcove or Under
Counter
0" (0 mm)
0" (0 mm)
1" (25 mm)
Closet
0" (0 mm)
10" (250 mm)
5" (125 ram)
Ventilation Requirements
WTA
3500
Alcove or
Under Counter
Ensure air flow
of 6,700 cu.ff./hr
(190 cu.m./hr)
through dryer
WTL
5400
Ensure air flow of 7,100 cu.ft./hr
(200 cu.m./hr) through dryer
Closet
Closet door must have 2
(Iouvered) openings,
each having a minimum
area of 60 sq. inches
(387 sq. cm.), located 3
inches (8 cm) from
bottom and top of door. *
Closet door must remain
open during dryer operation.
* - A Iouvered door with equivalent air opening is
acceptable.
Flooring
The dryer should be installed on a level, solidly
constructed floor. DO NOT install the dryer on a
carpeted floor.
Figure 3.
Built-in Installation
The Bosch dryer can be built-in: that is, you can
install the Bosch dryer under-countar in a kitchen cabinet opening. The cabinet opening should be
square and have the dimensions as shown in
Figure 3.
Note: If installed under a countertop, the countertop must be continuous and securely attached to neighboring cabinets.
DO NOT install the dryer in an area where gasoline or other flammable materials are kept or stored (including automobiles or other motorized vehicles).
The dryer must be installed in a room that is adequately ventilated. Make sure there is an adequate supply of fresh air. Both the WTA 3500, electric vented dryer, and the WTL 5400, electric condensation dryer need an adequate supply of fresh air for optimum performance
I
CAUTION:
DO NOT install the dryer in a closet with a solid door.
INSTALLATION
Step 1
Unpack the Dryer
Carefully remove the packing material from the outside of the dryer.
Step 2
Inspect the Dryer
Thoroughly inspect the dryer, prior to installation, for possible freight or cosmetic=damage. Report any damage immediately. Cosmetic damage must be reported within 5 days of installation.
Step 3
Position Dryer near Installation Area
Move the dryer so that it is within four feet of the desired position.
Note: Corrugated packing materia, may be used to protect the floor. Do not use corrugated material with staples.
Step 4
Exhaust
Duct
(Model W-FA 3500 Only!)
The WTA 3500 must be exhausted to the outdoors.
Be sure to install the exhaust according to all governing codes and ordinances. Rigid metal duct is recommended for venting this dryer. If flexible metal duct is used, be sure it is fully supported when the dryer is in its final position. Excess ducting should be trimmed off to avoid sagging or kinking of the ductwork.
The duct may be connected to the left, right or back of the WTA 3500, electric vented dryer. If connecting to the left or right hand side of the dryer, remove the sealing cover from the side to be used, as shown in
Figure 4.
6
1.
To reduce the risk of fire, this dryer
MUST BE EXHAUSTED OUTDOORS, when installed in an alcove or closet.
2.
DO NOT use non-metal duct with this dryer.
3.
DO NOT use duct smaller than 4 inches in diameter.
4.
DO NOT use exhau=t hoods with magnetic latches.
5.
DO NOT exhaust the dryer into a chimney, furnace cold air duct, attic, crawl space, or any other ductwork
used for venting.
6.
DO NOT install flexible
duct in an
enclosed
wall, ceiling or floor.
7.
DO NOT crush or kink the duct.
8.
Do clean and inspect the exhaust system on a regular basis; once a year, at a minimum.
9.
The exhaust duct must end with swing out damper(s).
Figure 4.
The sealing cover should then be placed over the open vent opening at the back of the dryer, as shown in Figure 5.
Figure 5.
The connecting piece supplied with your WTA 3500 dryer must then be inserted in the vent opening that will be used. See Figure 6.
12" (30 cm) min.
f
Figure 6.
Checking/Installing Exhaust Ducting
The ducting system of the dryer, for optimum
performance, should be as short as possible with a minimum number of elbows. Your WTA 3500 electric vented dryer will work best when the venting system
has as few restrictions to the flow of air as possible.
Whether installing to an existing venting system or a
new venting system, make sure that all ducting is clean and free of lint and does not exceed the length per elbows as shown in Table 1, below:
Number of Elbows
Maximum length of duct
Rigid
Duct
Flexible
Duct
2
3
0
1
30 ft. (914 cm)
22 ft. (670 cm)
14 ft. (427 cm)
6 ft. (183 cm)
20 ft. (610 cm)
15 ft. (457 cm)
9 ft. (274 cm)
4 ft. (122 cm)
Table 1.
Every elbow must have a minimum diameter of 4
inches (10 cm).
The above table assumes the use of an approved
exhaust vent hood with a swing out damper. DO
NOT use an exhaust vent hood with magnetic latches. To avoid restriction of exhaust the outlet must be a minimum of 12 inches (30 cm) above ground level, or any other obstructing surface, as shown below, in Figure 7.
Figure 7.
Step 5
Condensate Hose Connection
(Model WTL 5400 Onlyl)
The WTL 5400 must have its condensate drain line
installed and run to a suitable drain. The connection
for the condensate hose is located on the back of the
WTL 5400, see Figure 8.
Figure 8.
The condensate drain hose should already be connected to the dryer. The other end should then be placed and secured at a nearby sink or drain, or if installed with a washer it may, room permitting, be installed next to the washer drain hose and drained to the same drain used by the washer.
Be sure to follow all local codes and regulations in
running the condensate to a suitable drain.
Step6
Electrical
TheBoschdryercomeswith4-wirepowersupply as shownintheuppersectionofFigure1.
If your receptacle is a 3-wire receptacle, as shown in the lower section of Figure 1, a 3-wire "Dryer Cord" must be purchased locally. The 4-wire cord must then be removed and the 3-wire cord installed in its place,
Electrical Connection, 4-Wire
For a 4-wire system, all that is necessary is to plug the 4-wire power supply cord into the 4-wire receptacle of the proper rating.
Note: The receptacle should be located so that the plug and receptacle will be accessible when the dryer is in its final installed position.
Electrical Connection, 3oWire
If your receptacle is a 3-wire receptacle as shown below, Figure 9, you must obtain a 3-wire dryer cord.
Dryer cord can usually be found at your local hardware supply, electrical supply or home center.
Cord should have closed loop or upturned end wire terminating connectors.
__.
3- wire receptacle
(10-30R) _'_
Typical 3-wire Dryer Cord
240V/30 amp NEMA 10-30 Type SRDT
Figure 9.
Note: If the dryer is installed in a mobile home or in
areas where local codes do not permit
grounding, only a 4-wire power supply cord
shall be used.
To Change Cord:
1.
Make sure that the dryer is not plugged into any
power outlet.
DO NOT plug end of dryer power cord into a live receptacle before connecting dryer power cord to dryer terminals and closing junction/splitter box as described below.
DO NOT reuse old power supply cord.
Power cord must be changed only be a qualified person.
2.
Remove the screw from the cover of the junction/splitter box located at the top rear of the dryer
3.
Remove the green ground wire from the ground terminal.
4.
Remove the red, white and black wire from the terminal block.
5.
Loosen the 2 screws in the U.L. strain relief clamp, holding the 4-wire cable.
6.
Thread the 4-wire cable out through the U.L.
strain relief clamp and throw away.
7.
Thread the new 3-wire dryer cord through the
U.L. strain relief clamp.
8.
Attach the power cord Ground conductor (the center wire) to the Ground terminal. Tighten the terminal so that it securely holds the Ground conductor.
9.
Attach the two remaining power cord outer conductors to the 2 terminals labeled L. Tighten both screws so that the power conductors are securely held in place. See
Figure 10.
10. Tighten the screws on the U.L. strain relief so that the power cord cannot be moved.
CAUTION:
Do not slide dryer across the floor if leveling
legs have been extended. Legs and/or dryer
base may be damaged if dryer is slid across
floor with leveling legs extended.
L Ground
Figure 10,
11. Check the nut on the U.L. strain relief clamp to make sure that it is tight and the strain relief clamp cannot turn.
12. Replace the cover on the junction/splitter box and fasten in place.
The dryer is now ready to be plugged into the 3-wire receptacle, of the proper rating.
Note: The receptacle should be located so that the plug and receptacle will be accessible with the dryer in its installed position.
Additional Grounding Procedure
Some local codes may require a separate ground. In
such cases, the required accessory ground wire,
clamp and screw must be purchased separately.
Never ground the dryer to plastic plumbing lines, gas lines or hot water pipes.
Step 7
Position and Level the Dryer
Place the dryer in position on a clean, level, solidly
constructed floor. Installation on any type of carpeting
is not recommended.
With dryer in position, it must then be leveled.
Check dryer, using level as shown in Figure 11.
Figure tl.
The dryer should be level with all four feet firmly on the ground. The dryer must not wobble.
If the dryer is not level or if it does wobble, the legs must be adjusted. Refer to Figure 12. Adjust the leveling legs until the dryer does not rock and is level, both front-to-back and side-to-side.
Figure 12.
10
Step8
ConnectDuctSystemto Dryer.
(ModelWTA3500Onlyl)
Connect the exhaust ducting system to the dryer exhaust outlet.
Step 9
Final Check List
1.
Review the electrical requirements (and for WTL
model the exhaust requirements) and steps 1
through 8 to make sure they were performed properly.
2.
Make sure the electrical supply is on.
3.
Read the Use & Care manual to fully understand
how your dryer operates. Turn on the dryer.
Select the "Heated Dry" cycle and let the dryer
run for 2-5 minutes.
4.
After 2-5 minutes stop the dryer and open the
door. You should feel heat inside the dryer.
5.
If the dryer does not operate, refer to the SELF-
HELP and the SERVICE and REPAIR sections of
the Use and Care Manual.
6.
Upon completing check, turn dryer off.
7.
LEAVE INSTALLATION INSTRUCTIONS AND
USE and CARE MANUAL WITH OWNER.
II
12
508 0108 AB8
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Condensation drying technology: Dries clothes without the need for external venting, making it ideal for homes with limited space or no access to outdoor ventilation.
- Energy-efficient operation: Meets strict energy efficiency standards, reducing energy consumption and saving you money on utility bills.
- Sensor drying: Automatically adjusts drying time and temperature based on the moisture level of the clothes, preventing over-drying and preserving the quality of your fabrics.
- Wrinkle reduction: Special programs and features help minimize wrinkles, making ironing easier and saving you time.
- Large capacity: Accommodates large loads of laundry, reducing the number of drying cycles and saving you time.