James Hardie RD 600, RD 900, RD 1200 Irrigation controller Installation and Programming Guide
Reklaam
Reklaam
6, 9 & 12 Station
Indoor & Outdoor Controller
Installation and Programming Guide
For Models RD-600, RD-900, RD-1200 (EXT & INT)
James Hardie
Irrigation
Program Switch to select program LCD Display
Semi-Auto
Start Button
+/- Buttons
Multi-Function
Dial
*Modular design allows..
-Easy access to valve wiring terminals & battery
-Simple snap-out removal of module for convenient “anywhere” programming or service without disturbing installation
-Easy modular upgrade to as many as 12 stations
*Short circuit detection overrides an electrical malfunction of a valve, identifies it, and allows the other valves to water
*Default “fail-safe” program runs all valves for 10 minutes daily in case of program loss
*Rugged, weather resistant, lockable case comes with 2 keys
(outdoor models only) l 3 programs for different watering requirements such as trees, lawn and flower garden.
l 3 start times for each program, if desired
*“Skip day” scheduling for interval watering from 1 to every 1.5 days
*Fully automatic or semi-automatic operation
*Manual operation allows user to select valve(s) and watering duration
*Display shows current operation, including time of day
*Live programming allows program to be set or changed at any time, even during watering
*Off (or
rain)
setting stops all watering cycles without disturbing programs
*Battery back-up saves programs and keeps time during remote programming or power outage
Function Switch to set programs, run
auto,
manual or shut off
Q
Installing the Battery (Indoor and Outdoor Models)
Open the door to your controller, then pop the control module up by flexing the inside tab to your right. The battery compartment is located at the top in the back of the module. Open it. The alkaline connector is on the right and the
NiCad connector is on the left. Insert either a standard 9 volt alkaline or rechargeable NiCad battery onto the correct clip. Be sure to attach the alternate clip to the exterior plastic plug provided. The battery will preserve your program and run the clock during a power outage, but it will not operate the valves. CAUTION: If the battery is connected to the wrong terminal clip, it
may leak or explode.
Installing the Indoor Model Controller
Using the mounting template, locate your Rain Dial indoor model in an area protected from weather-such as a garage-within 5 feet of a standard (120 volt U.S.) electrical outlet. NOTE: Do not install on the same circuit as a high
power user such as a refrigerator, garage door opener or air conditioner. Insert a #10 screw into a wall stud, leaving about l/4” exposed to slip into the keyhole slot (shown above) on the back of your controller. To secure the controller, drive other screws through the holes (shown above) in back. Use wall anchors
until after valves are connected, see pages 7 and 8.
Installing the Outdoor Model Controller
Use the mounting template to locate the 3 mounting holes. Although you can locate your outdoor model almost anywhere, it is best to avoid direct exposure to sprinkler spray. Since this device is “hard wired,” keep in mind that you must run electrical cable to it. NOTE: Be sure that the ground wire is connected and
that the controller is not sharing the same circuit as a large appliance. Open the door to your controller, then pop the control module up by flexing the inside tab to your right. Locate your controller over the area you marked with the template, then drive 3 screws through the holes provided. Use wall anchors, toggle bolts or other appropriate fasteners when attaching to other than wall studs.
Inset-l a battery, see page 6. CAUTION: Do not connect to electricity until after valves are connected, see pages 7 and 8.
Connecting the Valves
CAUTION: Before connecting the valves to the controller make sure that it is unplugged (indoor model) or disconnected from power (outdoor model).
Open the inside door the same way in which you installed the battery. Route each valve lead wire through the hole in the bottom (use the left-hand hole on the outdoor model) to the desired numbered terminal, see page 8. Attach the ground wire from each valve to a single common wire and attach that wire to the “COM/GRD” terminal. Use the chat-l on page 18 to note which valve is operated by which numbered terminal.
NOTE: This controller is designed to work with 24 VAC, 5VA solenoid operated valves. A maximum of 2 solenoids per terminal may be used, and no more than 5 solenoids should be on at any one time. This includes the master valve and/or pump start, if one is being used. Current requirements should not exceed .25 amp. (6VA) for any solenoid.
Connecting a Master Valve or Pump
To use a master valve which operates throughout the watering cycle, connect your lead to the “MV" terminal and the ground to “COM/GRD.” NOTE: The
master valve must be equipped with a 24 VAC, .2 amp., 5VA solenoid. The controller should not be installed within 5 feet of a pump or pool equipment.
To use a pump, connect to the “MV” and “COM/GRD” terminals as described above.
The pump relay should have a nominal coil voltage of 24VAC at .25 amp.
maximum.
CAUTION: If you are using a pump start circuit, the fail-safe program will
activate the pump for all valves for 10 minutes each on Prog. A only. If all valves are not being used, the pump will run against a “dead head” on each unused valve. This can damage the pump. To avoid this, simply connect a jumper wire from the unused valve terminal to a valve terminal that is in use.
Indoor Model: After you have completed all valve connections and have a stable controller installation, route the two leads from your transformer through the bottom hole and connect to the 24 VAC INPUT terminals, then snap the control module closed. Plug the transformer into a standard 120 volt outlet. A flashing “12:O0 PM” should show on the display.
Outdoor Model: Outdoor controllers have a built-in transformer which must be connected directly to a grounded, 3-wire, 120 VAC power source. This connection should be made by a licensed electrical contractor in accordance with all requirements of the National Electrical Code and applicable state and local codes. NOTE: Local building and electrical codes usually require that ap-
proved electrical conduit and fittings be used to connect exterior, wall-mounted
equipment to 120 VAC power. CAUTION: DO NOT connect the controller
to one phase of a 3-phase power system used by a pump or other electrical equipment.
To connect power to an outdoor model controller, complete the following:
1. Turn off installation site power at the associated circuit breaker.
2. Verify that power has been turned off at the installation site by using an appropriate AC voltage meter.
3. Install the conduit and associated fittings.
4. Connect power and ground wires per electrical codes.
5. Turn power on.
6. Check controller operation. If the controller is not operating, transformer and check for shorts.
unplug the
Program Switch +/- Buttons
used to set up to 3 different programs for automatic operation, or to select a Use with Multi-Function Dial or in Manual mode to set or change program preset program (A, B or C) for semi-auto operation. After use in either mode, information. Single finger taps to either button advance or reduce data one switch position does not affect daily automatic operation.
character at a time. Holding either button down advances data at a rate of 12 characters / sec.
Function Switch
.Set to the left, it stops a programmed watering cycle and any valves that are on. In this mode, all programs are retained and the clock continues. Watering will not resume until the switch is returned to “RUN.” Set to the left when it rains.
.Set in the middle, the switch enables the user to set new programs, or change existing ones.
.Set to the right for normal, daily automatic operation.
LCD Display
.Shows current operation
Program Switch to select program LCD Display
Semi-Auto Start Button
.Used with Program Switch. When depressed, immediately starts program selected (A, B or C) regardless of automatic program cycle.
Manual Start Button
.Used with Multi-Function Dial and +/- Buttons. When depressed, operates any selected single valve for an amount of time selected by user.
Multi-Function
Dial
Multi-Function Dial
.Use with Manual Start Button for single valve operation.
.Use to set, check or change program information in conjunction with Number
Advance Buttons. After using, always return dial to “Current Time.”
fD
0
Function Switch to set programs,
run auto, manual or shut off
“Valve Run Time” Settings
These settings control how long each valve will water. The valve numbers correspond to the numbered terminals in back of the controller. The valves run sequentially; when one stops, another begins. You can set each valve to run from 1 minute to 5.9 hours.
“Start Times” Settings
Up to 3 different start times (time of day) can be selected for each program, up to 9 start times per day. These settings are especially useful for newly seeded lawns. NOTE: If a program from one day impinges on another program the next day, the controller will finish the first program.
“Schedule” Day Settings
Select which days watering is to occur by designating particular days of the week (for example, watering every Monday and Thursday), or setting skip day intervals (e.g. watering every 4 days). Days in either mode can be programmed “off.”
“Today” Setting
This setting is used with the skip day schedule. For example, if you want to water every 8 days, and you watered 4 days ago, you would enter the number
4 in the Today setting so that in 4 more days, your newly programmed watering cycle will begin.
Anywhere Programming
The Rain Dial control module is designed to be easily removed for complete programming in a more convenient setting, or service. The module’s battery power holds the program until the module is re-electrified. To remove the module, pop the module up as if you were going to replace the battery. Note the multi-pin plug on the upper left-hand face of the terminal board. Grasp the
“wiring harness” closest to the plug and pull it out from the terminal. Then unsnap the module from the 2 hinge points. After programming or servicing, reinstall the module by reversing the steps above.
Fail-Safe Mode
If the battery fails during a power interruption, your program will be lost. When power is restored, the Rain Dial controller automatically defaults to its fail-safe mode. Upon restoration of power, the fail-safe mode returns to Sunday at
12:00 p.m. and the clock runs from that point. Unless the controller is reprogrammed, it will run each valve for 10 minutes, beginning at 7:00 a.m. These
10 minute waterings are repeated every 24 hours. This feature is designed to protect lawns and plants from drying out from outages that occur while you are away for a prolonged period of time. NOTE: In freeze areas, disconnect the
controller while you are away to prevent activation of the fail-safe program.
c-- M u l t i - F u n c t i o n
Dial
I
I
_
,,
Select Valve Watering Times
1. Set Program Switch to “A”
2. Move Function Switch to “Set Programs”
3. Turn dial to valve number 1. Use the +/- buttons to enter how long valve is to water.
4. Repeat step 3 for valve number 2, valve number 3 and so on. Use the +/buttons to set unused valves to “Off .”
Repeat the above steps if you wish to use Programs “B” and “C.”
Dial in Start Time(s)
1. Turn dial to “1st Start Time.” Use the +/- buttons to enter the time when you want Program “A” to start.
2. If you want Program “A” to water more than once a day, turn dial to 2nd Start
Time. Repeat step 1 to enter a second start time, or press "-" for off.
Repeat for 3rd Start Time. To shut off start time. press the “+” button until vou reach 1159 PM. Then press "+" button once more to display Off.
Repeat the above steps if you wish to use
Programs "B" and “C.”
A
B c
Dial in Daily Schedule
First, decide whether you want to use the controller’s daily schedule (for example, water every Monday, Wednesday and
Friday) or the interval “Skip Days” schedule
(to water every third day, for example, set at 3) to activate your watering cycle.
Daily Schedule
Dial in Sunday. Use the +/- buttons for “On” or “Off.” Repeat this procedure for each succeeding day of the week. NOTE: When using this schedule, be sure to set the “Skip Days” setting to “Off .”
“Skip Days” Schedule
1. Turn dial to “Skip Days.” Use the +/- buttons to set the desired daily interval (for example, once every 8 days).
2. Turn the dial to “Today.” Use the +/- buttons to set which day in the cycle
“Today” should be, see page 12.
Repeat the above steps if you wish to use Programs “B” and “C.”
Set the Clock
1. Turn dial to “Current Time.” With the Function Switch still in the “Set Programs” position, use the +/- buttons to set the current time.
2. Turn the dial to “Today.” Use the +/- buttons to select the current day.
3. Return the dial to “Current Time.”
Activate the Controller
Activate the programming you have just entered by moving the Function Switch to the “Run” setting.
How to Check Your Program
Move the Function switch to “Off” and move the Program Switch to whichever program you wish to check, then turn the dial to the parameter you want to check. With the Function switch in the “Off” position, you can check, but you cannot change the programming.
Information Displayed When Programming
The LCD will display these kinds of data with the Function switch in the “Set
Programs” position, in conjunction with the following dial settings:
Valve Run Tides
Shows minutes (e.g., 15 MIN) or hours
(e.g., 1.5 HOUR). Also displays “OFF’ for unused valves.
Start Times
Displays time in AM, PM or OFF for unused start times.
Skip Days
Shows days numbered l-l 5, or OFF.
The words, “‘ONCE EVERY” appear to the left.
Schedule
Displays ON or OFF. If “Skip Days” has been set, 3 dashes (-) and the words, “SKIP MODE” will be displayed for each of the 7 daily settings.
SKIP - - -
MODE
Today
Displays 7 individual days for a weekly schedule, or displays day interval numbers (l-l 5) for a
“Skip Days” schedule.
Information Displayed When Operating
With the Function switch in the “Run” position, and the dial set to “Current
Time,” the number of any valve that is on will be displayed.
Automatic Mode With No Program On
With the Function switch in the “Run” position, the current
/ time with a flashing colon (:) is displayed. If the entire dis-
I play is flashing, the controller has just been plugged in or there has been a power outage. If the colon is not flashing, the controller is using battery power.
Automatic or Semi-Auto Mode
With Program On
Shows the current time. Turn the dial to a valve that is on, and the display will show the valve number, the program (A, B or C) and the time remaining for the valve to run. If you’turn the dial to a valve that is not currently on, the display shows “OFF’ (even though that valve may have a programmed run time).
r-2z-l
With the dial pointing to the appropriate valve, the display shows the valve’s number, an “M” (for manual mode), and the time remaining for the valve to run.
Short / Malfunction Detection
A flashing “OFF” indicates that the dial is pointing to a valve that has a short or other electrical malfunction.
NOTE: After a power outage or when the controller is energized, the display will flash 1 2 : 0 0 PM (or the current time if it was a short outage). Stop the flashing by pressing either of the +/- buttons.
Use the chart on page 19 to document your auto operation. Use the chart on this page to note your valve locations and their corresponding numbers.
9.
10.
11.
l
12.
5.
6.
7.
a.
1.
2.
3.
4.
Date installed
Date battery installed
Contractor Info:
Watering Considerations
Plants, soils and climatological conditions vary from region to region. Consult your local nursery for the watering schedule best suited to your particular requirements. As a general rule, the best time to water is early morning because evaporation, wind drift and temperature are minimal.
Evening watering may promote mildew and fungus growth.
P
R O G R A M M I N G
W
A T E R I N G
S
C H E D U L E
valve A
C
#tation Program Program Program Valve /Station Description
1
2
\
P/N 676406
Made In U.S.A.
Use semi-auto or manual operation to supplement regularly programmed
How to Check for Valve “Shorts”
watering cycles on especially hot or dry days.
Rain Dial controllers are uniquely able to detect and identify valves malfunction-
Semi-Auto Operation..
Runs an entire program (A, B or C) whenever you want a supplemental watering.
1. Make sure the Function Switch is in the “Run” position and the dial points to
“Current Time.”
2. Use the Program Switch to select the program (A, B or C) you want to run.
3. Press the Semi-Auto Start button.
The display will show whichever valves are on in the program you have selected. When the semi-auto cycle is complete, the controller will resume its regular schedule.
ing due to electrical shorts in their wiring. Use your controller to check any or all valves with a twist of the dial:
1. Make sure the Function Switch is set to “Run.”
2. Turn the dial to the valve you want to check.
3. Use +/- buttons to enter a run time.
4. Press the Manual button.
If the display flashes “OFF,” that particular valve has an electrical short or other problem. The solenoid and field wiring should be inspected. CAUTION: Do
not test valves by touching wire ends to terminal screws. Serious damage may result.
Manual Operation..
Runs a single valve for the amount of time you select. operate
1. Make sure the Function Switch is in the “Run” position.
2. Dial in the valve number (1-12) you want to run.
3. Use the +/- buttons to select the amount of time you want to water.
4. Press the Manual button.
The display will show an “M” (for manual), the valve number, and the time remaining for that valve to run. When the manual cycle is complete, the controller will resume its regular schedule. Return the dial to Current Time.
Manual Shut-Off
To shut valves off, make sure dial points to Current Time, then move the
Function Switch to “Off.” Scheduled watering will resume when the Function
Switch is returned to “Run.” a m “Start Times”
PROBLEM POSSIBLE CAUSE t CORRECTION
Watering at wrong times
Display blank
Program won’t display
Incorrect display (After a power outage or after being plugged in.)
Waters on wrong days
“Current Time” is wrong and flashing
Display is flashing
Valve won’t turn off
(Function switch “Off”)
“Current Time” of day ICheck and reset “Current incorrectly set
1 Time”
‘Start Times” incorrectly 1 Check and reset all “Start set Times.” See page 14.
No power Check circuit breaker panel
Check wiring, connections
Transformer plugged in?
,
Wrong function setting Function Switch must be in
“Run or Manual” setting
Controller is in watering Check or change program cycle with Function switch in
“Set Programs”
Battery is weak or Remove AC power and missing battery for 1 minute. Replace battery, restore power and reprogram
Weekly or “Skip Days” Reprogram. See pages 14 schedule incorrectly set and 15
Power outage occurred Replace battery and with no battery or weak reprogram controller batter-v in controller
Excessive load Check max. ratings, page 7
Shorted solenoid or Check solenoids and wiring, field wirinq see paqe 21
Mechanical override. Turn solenoid on top of valve
(Manual bleed is on) fully clockwise
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: l
Reorient or relocate the receiving antenna.
l
Increase the separation between the equipment and the receiver.
l
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
l
Consult the dealer or an experienced radio/TV technician for help.
This equipment has been verified to comply with the limits for a class B computing device, pursuant to
FCC Rules. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment Operation with non-approved equipment or shielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user’s authority to operate this equipment.
James Hardie
Irrigation
Hardie Irrigation offers complete lines of professional irrigation products for commercial and residential applications:
Controllers and Controller Accessories
Valves and Valve Accessories
Sprinklers, Nozzles and Sprayheads
Micro (Drip) Irrigation Components
Product inquiries
27631 La Paz Road
Laguna Nlguel. CA 92656
P/N 789401, Rev. A, 4/94
James Hardie
Irrigation
Manufacturing
9455 Railroad Drive
El Paso, TX 79924
0 1994 James Hardie lrrlgatlon
Laadi alla
Reklaam