HP 9X8LX/RX computer system Installation and Configuration Guide
PDF
Документ
Реклама
Реклама
HP 3000 Series 9X8LX/RX PA-RISC Computer System Installation and Configuration Guide Series 9X8LX/RX Family ABCDE HP Part No. A2051-90006 Printed in U.S.A. First Edition E1093 1993 Notice Hewlett-Packard makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and tness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Hewlett-Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett-Packard. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photographed, reproduced, or translated to another language without prior written consent of Hewlett-Packard Company. The information contained in this document is subject to change without notice. c Copyright Hewlett-Packard Company, 1993. All rights reserved. Printing History New editions are complete revisions of the manual. Update packages, which are issued between editions, contain additional and replacement pages to be merged into the manual by the customer. The dates on the title page change only when a new edition or a new update is published. No information is incorporated into a reprinting unless it appears as a prior update; the edition does not change when an update is incorporated. Many product updates and xes do not require manual changes and, conversely, manual corrections may be done without accompanying product changes. Therefore, do not expect a one-to-one correspondence between product updates and manual updates. First Edition : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : October 1993 iii List of Eective Pages List of Effective Pages The List of Eective Pages gives the date of the current edition and of any pages changed in updates to that edition. Within the manual, any page changed since the last edition is indicated by printing the date the changes were made on the bottom of the page. No information is incorporated into a reprinting unless it appears as a prior update. All : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : : October 1993 iv List of Effective Pages Safety and Regulatory Information For your protection this product has been tested to various national and international regulations and standards. The scope of this regulatory testing includes electrical/mechanical safety, radio frequency interference, ergonomics, acoustics, and hazardous materials. Where required, approvals obtained from third-party test agencies are shown on the product label. In addition, various regulatory bodies require some information under the following headings. v FCC Statement (USA only) FCC Statement (USA only) The United States Federal Communications Commission (in Subpart J, of Part 15, Docket 20780) has specied that the following notice be brought to the attention of the users of this product: Warning This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested for compliance with the limits of Class A computing devices pursuant to Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference. Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures may be required to correct the interference. vi Japanese Radio Frequency Interference Japanese Radio Frequency Interference Japanese Radio Frequency Notice vii Finland (only) Finland (only) LASERTURVALLISUUS LUOKAN 1 LASERLAITE KLASS 1 LASER APPARAT HP 3000 Series 9x8LX/RX -tietokoneisiin voidaan asentaa lisavarusteena muistilaitteeksi laitteensisainen CD-ROM-levyasema, joka on laserlaite. Kyseinen CD-ROM-levyasema on kayttajan kannalta turvallinen luokan 1 laserlaite. Normaalissa kaytossa levyaseman suojakotelo estaa lasersateen paasyn laitteen ulkopuolelle. CD-ROM-levyaseman on tyyppihyvaksynyt Suomessa laserturvallisuuden osalta Tyoministerion tyosuojeluosasto. Laitteen turvallisuusluokka on maaritetty valtioneuvoston paatoksen N:o 472/1985 ja standardin SFS-EN 60825 (1992) mukaisesti. Tiedot CD-ROM-levyasemassa kaytettavan laserdiodin sateilyominaisuuksista: Aallonpituus 790 nm Teho 1,1 W Luokan 1 laser viii Acoustics (Germany only) Acoustics (Germany only) Laermangabe (Schalldruckpegel LpA) gemessen an Arbitplatzbei normalen Betrieb nach DIN 45635, teil 19: Acoustic noise (A-weight sound pressure level LpA) measured at operator's position, normal operation, to ISO7779: HP 300 9X8LX/RX: 59dB bis (up to) 37&deg;C, 62dB ueber (above) 37&deg;C ix Safety Considerations Safety Considerations This product and related documentation must be reviewed for familiarization with safety markings and instructions before operation. The following gure shows some of the safety symbols used on the product to indicate various safety considerations. Warning The WARNING sign denotes a hazard. It calls attention to a procedure, practice, of the like, which if not done correctly or adhered to, could result in injury. Do not proceed beyond a WARNING sign until the indicated conditions are fully understood and met. Caution The CAUTION sign denotes a hazard. It calls attention to an operating procedure, practice, of the like, which if not done correctly or adhered to, could damage or destroy part or all of the product. Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met. Preface This manual is intended for use by trained and experienced Hewlett-Packard eld maintenance personnel. This edition of the Installation and Conguration Guide contains technical information about the HP 3000 Series 9X8LX/RX Family of computers listed in the table below. Computer Type Description HP 3000 928LX HP 3000 928RX HP 3000 968LX HP 3000 968RX 2 slot I/O chassis with a 48MHz CPU 4 slot I/O chassis with a 48MHz CPU 2 slot I/O chassis with a 64MHz CPU 4 slot I/O chassis with a 64MHz CPU Other Documents Referenced in this Guide: Part Number Title A1707-90016 5958-5859 5958-2370 50779-90012 HP 3000 and HP 9000 CE Handbook x Computer Products Site Preparation Resources Guide HP CEO Site Preparation Handbook HP Predictive Support User's Guide Safety Considerations xi Contents 1. About This Manual 2. Site Considerations Site Preparation Considerations . . Physical Considerations . . . . Electrical Considerations . . . . Specications . . . . . . . . . Hewlett-Packard Responsibilities . Third Party Service . . . . . . Customer Responsibilities . . . . Local Codes . . . . . . . . . Data Communications Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 2-1 2-2 2-2 2-5 2-5 2-7 2-7 2-7 3. Receiving The System Unpacking and Inspection . . . . . . . . . Unpack the HP 3000 9X8LX/RX Computer In Case of Damage . . . . . . . . . . . Physical Inventory . . . . . . . . . . . . Manuals . . . . . . . . . . . . . . . . Equipment . . . . . . . . . . . . . . . Computer . . . . . . . . . . . . . . . Claims Procedures . . . . . . . . . . . . Repacking . . . . . . . . . . . . . . . . Storage Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 3-1 3-4 3-4 3-4 3-4 3-4 3-4 3-5 3-5 4. Installation Installation Procedures . . . SPU Installation . . . . . System Console Installation Peripheral Equipment . . . . DTC Installation . . . . . PowerTrust UPS . . . . . External Disk Cabinet . . . Installation Completion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 4-1 4-3 4-4 4-4 4-4 4-5 4-5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contents-1 5. Starting the Computer System Turning On the Computer System . . Initial Power On . . . . . . . . . Power On Selftest and PDC Displays Installation Verication . . . . . . . Verier global status messages . . . Verier log le . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1 5-1 5-2 5-4 5-4 5-5 A. Remote Support Modem Conguration Quick Reference . . . . . . . . . . . . . HP Support Link (HP50759A) . . . . . . . Hayes Smartmodem 2400 . . . . . . . . . Black Box V.32 Plus (Version 2.01.01) . . . . Multitech MT224EH7 . . . . . . . . . . . HP 37212B . . . . . . . . . . . . . . . . Modem Cable Pin-out . . . . . . . . . . . Multifunction I/O PCA Modem Line Behavior CCITT Mode AP protocol 0 . . . . . . . Bell Mode AP protocol 1 . . . . . . . . CCITT BIS Mode AP protocol 2 . . . . . Modem Settings (HP Predictive Support) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 A-2 A-4 A-5 A-6 A-7 A-8 A-9 A-9 A-9 A-10 A-10 Contents-2 . . . . . . . . . . . . Figures 3-1. 3-2. 3-3. 3-4. Removing Loose Parts . . . . . . . Positioning the Shipping Box . . . . Raising the Flap . . . . . . . . . Removing the Computer from the Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 3-2 3-3 3-3 Environmental Specications . . . . . . . . . . . . 2-Slot and 4-slot Chassis Power Specications . . . . 2-Slot and 4-Slot Chassis DC Power Specications 3 . . Electromagnetic Susceptibility Specications . . . . . 2-Slot and 4-Slot Chassis Physical Specications . . . Technical Tasks/Personnel . . . . . . . . . . . . . A2941A Line Cord Options . . . . . . . . . . . . Settings for Remote Support Modem (Quick Reference) 8-Position DIP Switch Option Settings (Set S) . . . . 4-Position DIP Switch Option Settings (Set X) . . . . Switch Option Settings . . . . . . . . . . . . . . HP 37212B Switch Conguration . . . . . . . . . . 92219Q Cable Pin-out . . . . . . . . . . . . . . . Predictive Support Modems and Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 2-3 2-4 2-4 2-4 2-6 4-3 A-2 A-3 A-3 A-4 A-8 A-9 A-11 Tables 2-1. 2-2. 2-3. 2-4. 2-5. 2-6. 4-1. A-1. A-2. A-3. A-4. A-5. A-6. A-7. Contents-3 1 About This Manual This manual contains the installation instructions for the HP 3000 Series 9X8/LX/RX Family Computer Systems. This manual also contains information for installing the Distributed Terminal Subsystem and for conguring modems for remote support. This manual does not include instructions for installing networks. This manual is organized as follows: Chapter 1 About This Manual. Introduces the manual and describes its organization. Chapter 2 Site Considerations. This chapter denes HP organizations and lists site preparation responsibilities. Chapter 3 Receiving The System. This chapter provides information on receiving the system, instructions for unpacking the system, and putting it into position. Chapter 4 Installation. Contains installation procedures and conguration information. Chapter 5 Starting the Computer System. Provides instructions for turning on the equipment, booting MPE/iX, and running the verication program. Appendix A Support Link Modem Conguration. Provides conguration information on a number of modems that can be used for the support link modem. About This Manual 1-1 2 Site Considerations The HP 3000 9X8LX/RX family of computers are oce environment computer systems that do not require special environmental controls. For this reason, no specic site preparation is required before the system is installed. Even though the computer does not require any site preparation, there are some site considerations and responsibilities that need to be addressed. This chapter provides the environmental and electrical specications for the HP 3000 9X8LX/RX systems. These specications are provided to ensure the installation site is within the limits for the system. This chapter also lists the HP organizations and services available for site preparation for the HP 3000 9X8LX/RX family computers. It also lists and describes the responsibilities of the customer. Site Preparation Considerations The HP 3000 Series 9X8LX/RX computers are primarily designed to be used in commercial oce environments. Except for verifying the environment and AC power, very little site preparation is required. When the computer is congured into a larger system employing numerous peripherals and mass storage devices, you should study and become more familiar with the contents of this chapter. The CE or Site Preparation Specialist provides peripheral equipment power and environmental specications contained in the HP CEO Site Preparation Handbook and the HP 3000 and HP 9000 CE Handbook . It is the customers responsibility to ensure that the facility conditions are maintained in accordance with the information and specications contained in this chapter. This allows Hewlett-Packard to provide support services in accordance with the Customer Support Services Agreement . Physical Considerations Since the HP 3000 9X8LX/RX is a small physical package (refer to physical specs Table 2-5 it can be located next to a desk or placed in a dedicated computer room. Allow room for cables and access to the front and rear of the computer cabinet. Be sure to allow for the peripheral equipment that comes with a computer system, such as peripheral cabinets, PowerTrust UPS, terminals, printers and other supporting equipment. Also allow for computer materials storage. Site Considerations 2-1 Safety Considerations Electrical Considerations Be sure the nal installation site has enough AC outlets to support the computer and the peripherals located close to it. Be sure the outlets are grounded and are protected by a circuit breaker. Be very sure the AC power available meets the electrical specications. Refer to Table 2-2 for the exact electrical specications. Specifications Table 2-1. Environmental Specifications Description Operating Temperature Non-operating Temperature Specication to to 104F) -40 C to 65 C (-40F to 149F) (without internal DDS-format drive) 5 C 40C (41 F -40 C to 45 C (-40F to 113F) (with internal DDS-format drive - tape media limit) Maximum Rate of Temperature Change 20 C (36F)/hour (without tape media) 10 C (18F)/hour (with tape media) High Speed Fan (Activated) 30 C to 38 C (86 F to 100.4F) Overtemp Warning 40 C to 48 C (104F to 118.4F) Overtemp Hardware Shutdown Overtemp Warning +2 C (3 F) Operating Humidity 20% to 80% RH max wet bulb = 26C, non-condensing Non-operating Humidity 5% to 80% RH, non-condensing, less than 30% RH/hr rate of change Operating Altitude 0 to 3048 meters (10,000 ft) Nonoperating Altitude 0 to 4573.2 meters (15,000 ft) Heat Dissipation (max load) 1300 BTU/hr Operating Vibration (random) 0.0001 g2 /Hz, 5 to 350 Hz -6dB/Octave, 350-500 Hz 0.00005 g2 /Hz, 500 Hz ( 0.21 Grms ) Non-operating Vibration (sine) 0.5g (peak), 5 to 500 Hz Shock (nonoperating) Edge drop from 2.5 in. above oor Sound Power < 37 C = < 45 dB(A) sound pressure at operator's position. < 5.5 bels(A) sound pressure > 37 C = < 50 dB(A) sound pressure at operator's position. < 6.0 bels(A) sound pressure 2-2 Site Considerations Safety Considerations Table 2-2. 2-Slot and 4-slot Chassis Power Specifications Description Specication AC Input Voltage Range1 90 to 132 VAC and 180 to 264 VAC AC Input Current2 6.5 A maximum load @ 100 VAC 3.5 A maximum load @ 240 VAC 2.4 A typical load @ 100 VAC & 50 Hz 2.1 A typical load @ 120 VAC & 60 Hz 1.3 A typical load @ 208 VAC & 60 Hz 1.3 A typical load @ 220 VAC & 50 Hz 1.2 A typical load @ 240 VAC & 50 Hz AC Inrush Current 50 amperes peak, one cycle AC Input Power 380 watts maximum, 230 watts typical Power Supply Output Rating 240 watts DC continuous AC Input Line Frequency 47 to 63 Hz Transient Tolerance: 3000 volts, 10s, 500 ns rise/fall 1000 volts, 1.2s rise Low Energy High Energy Holdup without System Reset 20 ms @ 50 Hz (1 cycle) Battery Backup Time 15 minutes with optional 600 VA PowerTrust UPS Note The power supply is an auto-ranging power supply. It does not have to be recongured to operate over its rated operating ranges. However, the system should not be operated at voltages between the two input voltage ranges. 1 Typical load assumes 192MB memory, two internal disk drives, two peripherals, PSI I/O card, 802.3 LAN, and a 64MHz CPU. 2 The power supply can provide power for up to three internal peripherals. Site Considerations 2-3 Safety Considerations Table 2-3. 2-Slot and 4-Slot Chassis DC Power Specifications 3 Nominal Minimum Maximum Minimum Maximum P-P Ripple Voltage Voltage Current Current Voltage Note +5V4 3A 27A +5.10V +5.25V 50 mV +5V S 0A 5A +5.10V +5.25V 100 mV +12V 0A 6.67A +11.69V +12.36V 100 mV -12V 0A 2A -11.69V -12.60V 100 mV 3 Total power must not exceed 240 watts. 4 +5V current includes +5V S current. Table 2-4. Electromagnetic Susceptibility Specifications Radiated Conducted 3V/m, 28 MHz to 1 GHz 3V rms, 30 Hz to 100 MHz 1V rms, 100 MHz to 400 MHz Radiated Magnetic Field Immunity 1 gauss p-p, 48 Hz to 198 kHz Electrostatic Air Discharge 5 kV - no eect 25 kV - no hardware failure Electrostatic Contact Discharge 4 kV Table 2-5. 2-Slot and 4-Slot Chassis Physical Specifications Description 2-4 Site Considerations Specication Width 222 mm (8.74 in.) Height 430 mm (16.93 in.) Depth 533 mm (20.98 in.) Weight 31.8 kg (70 lbs) Safety Considerations Hewlett-Packard Responsibilities Each member of the Hewlett-Packard service organization is dedicated to making sure that each customer realizes the maximum benet from their computer system. HP is responsible for the installation and initial verication of the computer system. Table 2-6 summarizes a number of site preparation technical tasks and lists the personnel who should be responsible for completing each task. Third Party Service If an HP 3000 Series 9X8LX/RX Computer system and/or applications software is purchased from a \third party vendor", that third party is responsible for providing consultation services on the system operation and applications software. In the situation of a third party purchase, a maintenance agreement for hardware and Account Management Service (AMS) for software are available directly from Hewlett-Packard. Site Considerations 2-5 Safety Considerations Table 2-6. Technical Tasks/Personnel Technical Task Person Responsible Line voltage measured Electrician and HP CE Power line frequency measured HP CE Power line noise levels measured HP CE Neutral to ground levels measured HP CE Safety and ground connections veried Electrician and HP CE Advice on correct circuit breakers and wire sizes Electrician and HP CE Verication that maintenance power outlets (those used for oor cleaning, etc.) are on separate circuits from the computer system. Electrician Recommendations about lightning protection HP CE Measurements and recommendations on radiated interference HP CE Answers to questions concerning modems and modem options HP CE Thermal load of HP equipment HP CE Thermal load of non-HP equipment Customer/Vendor Total air conditioning required Customer/Contractor 2-6 Site Considerations Safety Considerations Customer Responsibilities The customer is responsible for scheduling, planning, and preparing a suitable environment for the complete computer system. The Hewlett-Packard CE will be available to assist the customer throughout the planning and preparation for and the installation of the system. In the Computer Products Site Preparation Resource Guide , read the Site Planning and Warranty Information (Section 1) and the On-Site Customer Documents (Section 2). Pay particular attention to the contents of the Customer Responsibilities page in Section 1 and the forms contained in Section 2. (The forms in Section 2 will be completed as the site planning preparation and equipment installation progresses.) Local Codes Special local codes exist in some locations regulating the installation of computer equipment. The customer is responsible for making sure the system is in compliance with all local laws, regulations, and codes for mechanical, building, and electrical distribution systems prior to system installation. Data Communications Equipment The customer is responsible for ordering and installing all required data communications equipment such as: Modems (Consult with CE for Hewlett-Packard requirements.) Telephone equipment Equipment supplied by companies other than Hewlett-Packard Any hardware or cables for connection or installation Site Considerations 2-7 3 Receiving The System This chapter contains information for unpacking and inspecting the computer, taking inventory of shipped goods, ling claims, repacking, and storing the system. Unpacking and Inspection The computer and its accessories may be shipped in more than one container. First, check to ensure that all the containers ordered by the customer are present, as specied in the carrier's Bill of Lading. Inspect each container for evidence of mishandling during transit. If any of the containers are damaged, request that the carrier's agent be present when the container is opened. Unpack the shipping containers and inspect each item for damage. Look for damage such as broken controls and connectors, dented corners, scratches, bent panels, and loose components. Check the rigid foam packing material for signs of damage, which could indicate rough handling during transit. Unpack the HP 3000 9X8LX/RX Computer The unpacking of the computer is shown on the ap of the shipping box. To remove the computer from the shipping box, perform the following steps: Warning DO NOT try to lift the computer out of the shipping box. The shipped weight of the computer exceeds 70 pounds (32 kg). If the computer is dropped it could cause injury and will cause damage to the internal components of the computer. Receiving The System 3-1 Safety Considerations 1. Remove all loose parts inside the shipping box, and the inside shock absorbing packing materials. See Figure 3-1. Figure 3-1. Removing Loose Parts 2. Close the ap with the handles cut in it, the other three aps should be open. 3. Position yourself so that you must reach across the box to grasp the handles. See Figure 3-2. Figure 3-2. Positioning the Shipping Box 3-2 Receiving The System Safety Considerations 4. Grasp the handles and carefully pull the shipping box toward yourself until the shipping box rests on its side, with the handles on top. This positions the computer in an upright position, resting on its feet. See Figure 3-2. Note The feet on the bottom of the computer slide easily on cardboard. They should also slide easily over hard oors or carpets. 5. Open the top ap. See Figure 3-3. Reach into the shipping box and grasp the computer on the left and right side. Figure 3-3. Raising the Flap 6. Pulling alternately with your left and right hand, slowly slide the computer out of the shipping box. See Figure 3-4. Save the shipping box and packing materials in case the computer needs to be moved to another location. Figure 3-4. Removing the Computer from the Box Receiving The System 3-3 Safety Considerations In Case of Damage If damage is observed, refer to the claims Procedures section later in this chapter. Physical Inventory When the shipping containers is opened, locate the picklist which contains a list of equipment supplied. Compare the product and option numbers on the picklist with the purchase order to verify that the shipment is correct. Manuals Ensure that all of the manuals listed have been received. If any of the manuals are damaged or missing, refer to the Claims Procedure section. Equipment Ensure that all of the equipment on the list has been received. If any of the equipment is damaged or missing, refer to the Claims Procedures section. Computer Ensure that the model and serial numbers are identical to those specied on the picklist. The model and serial numbers are printed on a general information label, located on the back of the computer. The computer comes with some peripherals embedded in the SPU cabinet. Check that these peripherals are integrated and that they match the equipment list. The general information label contains the serial numbers of the embedded peripherals, along with regulatory approvals and electrical ratings. Claims Procedures Notify the nearest Hewlett-Packard Sales and Service Oce if the shipment is incomplete, damaged, or fails to meet specications. If damage occurred in transit, notify the carrier as well. Hewlett-Packard will arrange for replacement or repair without waiting for settlement of claims against the carrier. In the event of damage in transit, retain the packing container and packing materials for inspection. 3-4 Receiving The System Safety Considerations Repacking When computers must be reshipped, use the original shipping and packing materials, if available. Contact the local Hewlett-Packard Sales and Service Oce for repacking information and materials. Storage Requirements Hewlett-Packard computer equipment can be stored or shipped in environments that fall within the following limits: Storage Temperature (with tape media): -40 to 45 C (-40 to 113 F) Storage Temperature (without tape media): -40 to 65 C (-40 to 149 F) Rate of change (with tape media): <10 C/hr. Rate of change (without tape media): <20 C/hr. Non-operating humidity; 5% to 80% non-condensing Humidity rate of change: <30% RH/hr. Caution The computer and components should be protected from environmental extremes that can cause condensation within the equipment. When installing the equipment, allow time for the temperature of the equipment to stabilize to the site environment. Receiving The System 3-5 4 Installation This chapter contains information for installing the HP 3000 Series 9X8LX/RX Family Computer systems. All installation tasks should be performed by trained and experienced personnel only. The installation tasks are as follows: System Processor Unit (SPU) Installation System Console Installation Peripheral or Optional Equipment consisting of: Datacommunication Terminal Controller (DTC) Installation PowerTrust UPS Installation External Disk Cabinet Installation Warning Be sure the SPU is not plugged into a wall outlet or PowerTrust UPS before starting the Installation Procedures. Installation Procedures Tools required: Standard CE hand tool set, plus a #10 Torx driver. SPU Installation To install the SPU, perform the following steps: 1. Observe all ESD precautions while performing installation procedures on any electronic equipment. 2. Remove the I/O RFI covers from the slots that will hold any I/O cards to be installed. Note Refer to the CE Handbook (part number A2051-90003) for specic details on I/O card slot loading and conguration information. 3. Install optional I/O cards into an appropriate I/O slot. Make a note of the type of card inserted into the I/O slot, as well as the slot number. This information will be used during system conguration. 4. Connect all external peripherals to the appropriate I/O connector at the back of the SPU. Installation 4-1 Safety Considerations a. The top connector on the multifunction I/O card is for SCSI peripherals. If there are no additional SCSI peripherals to connect, install a SCSI terminator (part number 1252-3932) to the SCSI connector. b. Refer to the documentation that came with the peripheral device for specic installation instructions for that device. c. Use only the cables that come with the peripheral device. Note SCSI cable part numbers are listed in Chapter 8 of the CE Handbook . Chapter 4 of the CE Handbook has external SCSI cabling and conguration information. d. Make a note of all device addresses that apply to system conguration, along with the slot number that they are connected to. Refer to the note in step 1. e. Connect a BNC T connector to the ThinLAN connector on the Multifunction I/O card. Note The ThinLAN connector is enabled at the factory, and the AUI LAN connector is disabled. If the AUI LAN connector needs to be enabled, the Multifunction I/O card has to be removed and jumper block W1 needs to be repositioned. Refer to the CE Handbook, Chapter 4 for more conguration information. f. Do not leave any open I/O slots after all I/O cards are installed. This would violate the RFI specications accommodated by the I/O slot covers. 5. Plug one end of the line cord into the AC receptacle at the rear of the SPU. Note Be sure the appropriate localized line cord (refer to Table 4-1 for line cord selection) is available with the SPU. Also, if the computer comes with a PowerTrust UPS, the UPS has to be installed before the SPU is powered up. The lime cord that comes with the SPU is used as the AC line cord for the UPS, and the SPU connects to the UPS with one of the convenience cords that come with the UPS. 4-2 Installation Safety Considerations Table 4-1. A2941A Line Cord Options Part Number Country Male Type 8120-1351 United Kingdom BS1363 8120-1369 Australia AS3112 8120-1689 Europe CEE7/VII 8120-1751 US 120V 5-15P 8120-3996 US 240V 6-15P 8120-2104 Swiss SEV type 12 8120-2956 Denmark DHCR 8120-4211 South Africa SABS 8120-4753 Japan JIS C 8303 System Console Installation The recommended system console terminal for the HP 3000 9X8LX/RX family of computers is the HP 700/96 terminal. If the customer uses any other type of terminal for the system console, refer to the documentation that comes with the equipment for any installation information. HP 700/96 System Console 1. Connect the system console cable (part number A1703-63003) to the Multifunction I/O card connector labeled Console, on the rear of the SPU. 2. Connect the other end of the system console cable to the console connector labeled DATACOMM., located on the back of the console. Refer to the documentation that came with the console for specic installation instructions that apply to the device being used as the system console. 3. The HP 700/96 terminal default settings match the system requirements for terminal conguration. Installation 4-3 Safety Considerations Peripheral Equipment Be sure to refer to the documentation that comes with any peripheral equipment for specic installation instructions. DTC Installation There may be multiple DTCs to be installed on the system. Repeat the installation instructions for each DTC installed on the system. 1. The DTC is connected to the SPU through the LAN link. 2. Connect another BNC T connector (part number 92227N) to the connector labeled LAN Interface on the back of the DTC. 3. Connect the LAN cable (all ready connected to the SPU) to the DTC BNC T connector. 4. If there is another DTC, connect a LAN cable from the other end of the BNC T connector to the next DTC. 5. On the last DTC installed, connect a LAN terminator (part number 92227P) to the remaining side of the BNC T connector assembly. 6. Cover all the BNC T connector assemblies with the fabric anti-static cover that came with the T connector. 7. Refer to the documentation that came with the DTC for complete installation and conguration instructions. Note Be sure that each end of the system LAN link has a BNC LAN Terminator (part number 92227P) installed. PowerTrust UPS To connect the PowerTrust UPS to the SPU, perform the following steps: 1. Locate the PowerTrust System Guide (part number 5961-8383). 2. Take the time to thoroughly read and understand all the necessary procedures outlined in the PowerTrust Guide. The PowerTrust requires recharge time before it is considered ready for normal operation. Note 4-4 Installation The line cord for the computer is used as the line cord for the UPS. The computer is connected to the UPS with a convenience cord supplied with the UPS. Be sure the appropriate localized line cord is used with the UPS (refer to Table 4-1). Safety Considerations External Disk Cabinet To connect the external disk cabinet to the SPU, perform the following steps: 1. Be sure the disk cabinet ON/OFF switch is in the OFF (0) position. 2. Plug the power cord into the back of the disk cabinet, just below the ON/OFF switch. 3. Connect the end of the SCSI cable (part number 5062-3383 or K2296) to the bottom SCSI connector on the back of the disk cabinet. 4. Connect the other end of the SCSI cable to the top connector labeled SCSI on the computer back panel. Be sure the connector is securely fastened to the computer back panel. 5. Connect the external disk SCSI terminator (part number 1252-3920 or K2291) to the top connector on the back of the disk cabinet. 6. Plug the disk cabinet power cord into an appropriate ac wall outlet. 7. This completes the hardware installation of the external disk cabinet. Refer to the documentation that comes with the disk cabinet for any additional information. Installation Completion 1. Make sure all (SPU and peripheral devices) power switches are in the OFF position. 2. Connect the SPU power cord to an appropriate AC outlet, or PowerTrust UPS outlet. 3. Connect all peripheral device power cords to appropriate AC outlets. The computer system should now be ready for initial power up selftest, and system conguration. Continue to Starting the Computer System Chapter 5. Installation 4-5 5 Starting the Computer System The procedures listed in this chapter show you how to interact with the computer to get you to the ISL (Initial Software Load) prompt (ISL>_). When the ISL prompt is displayed, the command to load the MPE/iX operating system software can be issued. Turning On the Computer System The computer and its external equipment contain built in selftest programs. These programs automatically run each time the computer and the equipment are turned o and then turned on again. Remember, depending on how much internal memory the computer has, the computer selftest can take up to approximately 2 to 5 minutes to complete. Caution Do not move the computer or disk cabinet while the power is on. Moving the equipment while power is on can cause disk damage and loss of data. Initial Power On When turning on the computer system (this includes all equipment) be sure to follow the sequence listed below: Caution If any of the external equipment has been OFF due to any environmental problem, such as heating or air conditioning failure, allow approximately 30 minutes for the temperature of the equipment to stabilize before turning on the computer. 1. Turn on all the external equipment (except the DTC) connected to the computer rst. The DTC will be turned on later. 2. Check all READY or ONLINE indicator lights on the external equipment to be sure that they indicate being powered up and ready. 3. When all external equipment indicate READY or ONLINE by their particular indicator lights, press the computer ON/OFF switch to the ON position. Starting the Computer System 5-1 Safety Considerations Power On Selftest and PDC Displays The primary display for the computer is the system console in conjunction with the status display lights on the front of the computer. 1. The rst thing displayed on the computer console is a line of messages along the bottom of the console screen indicating the selftest programs are running: c TEST nnnn REMOTE: disabled inactive multiple ACCESS FAULT: yy While this display is active the amber Attention light should be on. This indicates that a test is being performed. 2. When selftest is complete, the console displays a screen similar to the following: d b a --------------------------------------------------------------------------xx MB of memory configured and tested. Primary boot path: 56/52.6 (dec) Alternate boot path: 56/52.0 (dec) ---- Main Menu -----------------------------------------------------------Command ------- Description ----------- BOot [PRI|ALT|<path>] Boot from specified path PAth [PRI|ALT] [<path>] Display or modify a path SEArch [DIsplay|IPL] [<path>] Search for boot devices COnfiguration menu INformation menu SERvice menu Displays or sets boot values Displays hardware information Displays service commands DIsplay Redisplay the current menu HElp [<menu>|<command>] Display help for menu or command RESET Restart the system -------Main Menu: Enter command or menu> c 5-2 Starting the Computer System b Safety Considerations The xx MB indicates the amount of memory in the system. Within the main menu, the commands or menu can be entered with the letters in capitals, for example; booting from the primary boot path would be: Main Menu: Enter command or menu>BO PRI 4Enter5 or a menu request would be: Main Menu: Enter command or menu>IN 4Enter5 Where the IN entry would display the system hardware information. 3. At the Main Menu: Enter command or menu> prompt, enter the boot from primary boot path command (BO PRI). 4. The system returns a query of: Interact with IPL Y/N?> Type Y 4Enter5. The HP 3000 9X8LX/RX systems do not have the autoboot function enabled, you must interact with the Initial Program Loader (IPL) software. An N entry will still put you into IPL. 5. At this point the Initial System Loader (ISL) prompt (ISL>) is displayed. The system should be waiting for your response to the ISL> prompt. 6. Respond to the ISL> prompt with the START command, (or any of the applications available in ISL). The START command launches the MPE/iX operating system software. ISL> START 4Enter5 7. After a few minutes, you are prompted to conrm the date and time as shown below. If you do not respond within 15 seconds, the system accepts the displayed date and time by default, and continues with the start-up process. a. If the date and time displayed are accurate, type Y and press 4Return5, or wait for the time out. b. If they are not, type N and press 4Return5 within the 15 seconds allowed. Enter the correct date and time when prompted. Time must be entered in 24-hour format (for example, 5:00 pm, is entered as 17:00). Seconds default to 00 if not specied. d MPE/iX launch facility Initialize_genesis - Version : <<870204.1552>> TUE, AUG 11, 1993, 10:20:03 AM (y/n)? Y [TMUX_DAM] n n n n Initialize genesis completed. c a b The fundamental operating software is starting. Starting the Computer System 5-3 Safety Considerations d During the launch of the MPW/iX operating system ERROR and WARNING messages will be displayed on the console telling you that uncongured devices are attached to the system. These messages are normal during the rst boot up. They appear during the rst boot up because the nal conguration is not done. Among the messages you may see are these: DCC warning 103-5, Add ldev to class failure (HLIO status FF6A00BD,. a DCC warning 103-5, Add ldev to class failure (HLIO status FF6A00BD,. cDCC STARTUP - ERROR b The system is making many internal checks and is reporting that the conguration is not complete. When this checking process is complete a welcome message is displayed on the console. You are automatically logged on to the system as OPERATOR.SYS. 8. When the system prompt (:) is displayed, all the system selftests are complete. At this time, turn on the DTC(s). The conguration process can begin. Installation Verification Once the conguration is complete, the system installation can be veried by the use of the Verier program. The Verier program usually resides in the DIAG group of the SYS account. However, a command le named VERIFY.PUB.SYS is provided to setup the proper environment for Verier operation. To invoke MPE/iX Verier log on as Manager.Sys (or any log on with SM, OP or DI capability) and enter the following: VERIFY Follow the program prompts on the console screen. Verier performs more than one task at one time. For this reason, you will frequently see messages for assorted devices interspersed with one another, this is normal. Verifier global status messages When Verify is nished it prints one of three status messages indicating: d c If everything veried as okay a message similar to the following appears: System verification is complete. Everything is okay. Proceed with the next operation... If something needs attention , a message similar to the following appears: 5-4 Starting the Computer System a b Safety Considerations d c a ATTENTION: System verification indicates that noncritical devices are not all working. b This message indicates a problem with a noncritical device. A noncritical device is everything except : system disks, nonsystem (private volume) disks and tape drive logical device 7. d c If there is an error , a message similar to the following appears: a ERROR: System verification failed. Critical devices are not functional. Do not continue to use the system. b This message indicates a critical device failed. You should not attempt to use the system until the problem has been corrected. Critical devices are all system disks, all non-system (private volume) disks and tape drive logical device 7. Verifier log file In addition to the messages described above, MPE/iX Verier creates a log le named VERLOG. This le contains a detailed history of the verication actions and status messages and a system I/O map which shows the current status of each device and the overall system status. VERLOG is created in the group and account from which Verier is invoked. However, a le equation can be used to redirect it to another location. Starting the Computer System 5-5 A Remote Support Modem Configuration This section contains information for connecting specic modems to the HP 3000 9X8LX/RX Family Computer System. This section also discusses the signal line behavior of the Multifunction I/O modem interface to aid in conguring modems that are not listed. General rules for conguring modems: The modem must be set up to respond to DTR. CTS should follow RTS. DSR must follow OH, not DCD. For Bell mode, the modem should disregard RTS. Set both local and remote modems to either: the same compression mode, OR to NO data compression. If problems occur connecting two modems, usually the fault is that one is enabled for some MNP level and the other modem is set for no data compression. If the modem sends up-modem dialog with all of the signals asserted, it is possible for the user to be logged o immediately when a password is enabled for the Access Port. This can be corrected by setting the modem so it does not report connection status via the data path. Note V.22bis/V.25bis modes are not supported on the A1703-60003 or A1703-60022 Multifunction I/O interfaces. Remote Support Modem Configuration A-1 Safety Considerations Quick Reference Table A-1 is a quick reference table for the supported modems for remote support. For detailed information, refer to the appropriate section of this appendix. Table A-1. Settings for Remote Support Modem (Quick Reference) Modem Model Settings HP50759A (Support Link) X1, X2, X3, X4, and S8: Down S1, S3, S4, S5, and S6: Up S2 and S7: Do not care Hayes Smartmodem 2400 S3, S9, and S10: Down S1, S4, S5, S6, and S7: Up S2: Do not care Black Box V.32 Plus (2.01.01) AT&D2&S1&C1&R (See Black Box V.32 section for details) Multitech MT224EH7 X1, X4, S3, S7, and S8: Down X2, X3, S1, S2, S4, S5, and S6: Up HP 37212B S1, S2, S4, S5, S6, S7, and S10: Down (0) S3, S8, S9, S11, and S12: Up (1) HP Support Link (HP50759A) Supported modes: Bell CCITT OM CCITT AM CCITT BIS OM CCITT BIS AM Supported cables: HP 92219Q - Bell, CCITT OM, CCITT AM A1703-63006 - CCITT BIS OM, CCITT BIS AM A-2 Remote Support Modem Configuration Safety Considerations Auto-dial modes: Hayes This modem is the standard HP Support Link. It supports V.22bis line discipline, but does not support V.25bis auto-dialing. In order for V.22bis answer mode to work properly, DSR must follow OH. Data Compression should be set OFF . Setting data compression ON can cause problems when connecting to other modems that do not have data compression. Table A-2. 8-Position DIP Switch Option Settings (Set S) Switch S1 S2 S3 S4 S5 S6 S7 S8 Note Position up xx up up up up xx down Description DTR Normal Verbose Responses Suppress Responses Enable Echo of commands Enable Auto-Answer DCD/DSR Normal Depends on phone line Enable Command Mode Option Command &D2 V1 &Q0 E1 S0=1 &C1 &S1 xx means do not care. Table A-3. 4-Position DIP Switch Option Settings (Set X) Switch X1 X2 X3 X4 Note Position down down down down Description CTS Normal DSR Follows OH Use HP Defaults No ENQ/ACK Pacing Option Command &R0 &S1 &E0 &E3 &E6 &E10 &E14 $BA1 &E8 An ATl5l7 command should have the following output: B0 E1 M1 Q0 V1 X0 &E0 &E3 &E6 &E8 &E10 &E14 &Q0 $MB2400 $SB2400 $BA1 &W1 &A0 $A0 &B0 &BS1 &C1 &D2 $D0 $F1 &G0 &I0 &M0 $MI0 &R0 $R0 &S1 &T5 &V1 &W1 OK Remote Support Modem Configuration A-3 Safety Considerations Hayes Smartmodem 2400 Supported modes: Bell CCITT OM CCITT AM Supported cables: Must use 92219Q modem cable. Auto-dial modes: Hayes. This modem drives circuit 111 (Pin 23) instead of using it as an input. With either cable (92219Q or A1703-63006), the Multifunction I/O PCA and the modem, drive the same line. Caution This modem should not be used because all HP cables connect circuit 111 to the modem. If this modem is connected, both the Multifunction I/O PCA and the modem drive circuit 111. This modem has been used in the past with the CIO based AP card and had the same problem. Turn o all data compression modes. The Hayes defaults for the modem lines must be changed to the following: Table A-4. Switch Option Settings Switch S1 S2 S3 S4 S5 S6 S7 S9 S10 Note A-4 Position up xx down up up up up down down Description DTR normal Option Command AT&D3&W Result codes disabled Characters echoed Auto-Answer enabled Detect Carrier RJ-11 CCITT Return to command state ATQ1&W ATE1&W ATS0=1&W AT&C1&S1&W AT&J0&W ATB0&W AT&D3&W xx means do not care. Remote Support Modem Configuration Safety Considerations Black Box V.32 Plus (Version 2.01.01) Supported modes: Bell CCITT OM CCITT AM Supported cables: Must use 92219Q modem cable. Auto-dial modes: Hayes. This modem does not work with v.22bis because it does not supply 112 and because the sense of 111 is backwards (TRUE means low speed, FALSE means high speed). The fact that 111 is backwards is not too big a problem because the modem can be congured to ignore 111. Change so that DTE Fallback is Disabled . This is the factory default. Not supplying 112 means that the Multifunction I/O PCA always thinks it is running at the lower speed. If you set the speed for twice the desired speed, then it will work at the desired speed. It is best not to use this modem with any of the CCITT bis protocols. The Black Box defaults for all of the modem lines are incorrect and must be changed before this modem will work properly. To do this from the front panel, go into the Change DTE Parameters and set the following: Responds to DTR DSR is Normal DCD is Normal CTS follows RTS This can be done with the following AT command: AT&D2&S1&C1&R For Hayes dialing, make certain that the AT command set is enabled. It is normally good to disable status messages to the host by using the ATQ1 command. The current conguration can become the power-on conguration by using the AT&W command. This modem does not do any rate shifting. So the DTE rate and the DCE rate must be the same. This modem seems to work in AP mode with the protocol set to either Bell or CCITT. It does not work with the modem protocol set to CCITT BIS. Make certain to congure the modem to ignore 111, or congure the Access Port to set FS low. It also seems to work ne in normal mode (i.e. under host control). Remote Support Modem Configuration A-5 Safety Considerations Multitech MT224EH7 Supported modes: Bell CCITT OM CCITT AM CCITT BIS OM CCITT BIS AM Supported cables: HP 92219Q - Bell, CCITT OM, CCITT AM A1703-64006 - CCITT BIS OM, CCITT BIS AM Auto-dial modes: Hayes, V.25bis. Note The version of the modem has a problem when dialing with V.25bis where if the number that is dialed is busy, DSR does not drop. This same problem causes V.25bis error indications to be improperly decoded, meaning that the modem time-out timer must expire before we know that the attempt failed. This also means that multiple dialing attempt will always fail. If the DSR jumper is set so that DSR follows DCD, this problem goes away. The conguration of the hardware switches on the modem are: 8-position DIP-Switch (S switches): Switch: 1 2 3 4 5 6 7 8 -------------------------------------------------UP UP DOWN UP UP UP DOWN DOWN 4-position DIP-Switch (X switches): Switch: 1 2 3 4 ----------------------------DOWN UP UP DOWN For Hayes mode to work correctly, AT&R0 must be set so that it drops CTS when the connection goes down. For Hayes, AT$V0 must be set. For V.25bis dialing, VT$V1 and AT$BA1 must be set. Hayes dialing parameters: B0 E1 M1 Q0 R0 V1 X0 &E1 &E4 &E6 &E8 &E10 &E13 &E15 $MB2400 $SB2400 $BA1 &W0 S0 S2 001 043 S3 S4 S5 013 010 008 S6 S7 S8 002 030 002 S9 S10 S11 S12 006 007 070 050 $A0 &A0 &B0 &BS1 &C1 $D0 &D2 #DB0 $EB0 $F1 &G0 #L0 $MI0 &M0 &P0 #P2 &Q0 &Q3 $R0 &R1 &S1 $T1 &T4 $V0 $VD0 &X0 Y0 $MB2400 $SB2400 $BA1 &W0 OK A-6 Remote Support Modem Configuration S24 S25 S30 020 000 000 Safety Considerations For V.22bis auto-answer, internal jumper DSR must be set so that DSR follows OH. The factory default is for DSR to follow CD. This is dierent from the Support Link where the factory default was for DSR to follow OH. There does not seem to be an AT command that does this. V.25bis dialing parameters: B0 E1 M1 Q0 R0 V1 X0 &E1 &E4 &E6 &E8 &E10 &E13 &E15 $MB2400 $SB2400 $BA1 &W0 S0 S2 S3 001 043 013 S4 S5 S6 010 008 002 S7 S8 S9 030 002 006 S10 S11 S12 007 070 050 S24 S25 S30 020 000 000 $A0 &A0 &B0 &BS1 &C1 $D0 &D2 #DB0 $EB0 $F1 &G0 #L0 $MI0 &M0 &P0 #P2 &Q0 &Q3 $R0 &R1 &S1 $T1 &T4 $V1 $VD0 &X0 Y0 $MB2400 $SB2400 $BA1 &W0 VAL To modify a MT224E7B: Open modem and change the DSR jumper. Set switches on the bottom of the box to above. Send AT&R0 For Hayes dialing, send AT$V0. For V.25bis dialing, send AT$V1. HP 37212B Supported modes: Bell CCITT OM CCITT AM CCITT BIS OM CCITT BIS AM Supported cables: HP 92219Q - Bell, CCITT OM, CCITT AM A1703-64006 - CCITT BIS OM, CCITT BIS AM Auto-dial modes: None It is best to use this modem in CCITT mode because it causes the Access Port to hang up if used in Bell mode at 1200 baud. It can be used in Bell mode at 2400 baud, or either 1200 or 2400 in CCITT mode. This modem can not be dialed with either Hayes or V.25BIS auto-dial protocols. Table A-5 describes the switch settings. Remote Support Modem Configuration A-7 Safety Considerations Table A-5. HP 37212B Switch Configuration Switch Position Note Description S1 down S2 down S3 up S4 down Primary channel S5 down 1 start, 8 data and 1 stop S6 down S7 down Error correction disabled S8 up No Flow control S9 up S10 down S11 up S12 up Computer mode operation (HP command set) DSR/CTS/CD to RS-232-C denition DTR behaves to RS-232-C denition Although this modem claims to be able to dial using V.25bis, it only uses the V.25bis line discipline. The command set does not match the set specied in the V.25bis specication. Modem Cable Pin-out Table A-6 list the pin-outs for the 92219Q cable, which is most often used to connect the Access Port to the support modem. A-8 Remote Support Modem Configuration Safety Considerations Table A-6. 92219Q Cable Pin-out Computer End Signal Name Modem End 2 TD 3 3 RD 2 8 RTS 4 22 CTS 5 20 DSR 6 6 DTR 20 9 RI 22 DCD 8 23 FS 23 7 GROUND 7 4 and 5 The pin-out for the A1703-63006 cable is the same except that pin 9 on the computer end is routed to pin 12 on the modem end and that Line functions as Rate Select (RS). This cable is only used with the A1703-60003 SCSI/Console/LAN Multifunction I/O interface for V.22bis/V.25bis applications. Multifunction I/O PCA Modem Line Behavior CCITT Mode AP protocol 0 This protocol is known as HP-UX CCITT. The card waits for RI before raising DTR. It also raises RTS when it raises DTR. If DSR does not come up within 25 seconds, DTR goes back down. The connection also depends on CTS and DCD. DCD can drop for up to 400ms before the connection will drop. CTS must stay high always. Once CTS drops, the connection starts to drop. A new connection cannot occur until DSR, DCD and CTS all drop. FS can be programmed to either state via the CA command. Bell Mode AP protocol 1 This is sometimes called Bell simple protocol. It raises DTR when it can accept a connection. The connection is valid when it sees DCD. It drives RTS whatever it was when Remote is enabled (usually, RTS is low) and does not look at DSR or CTS. When a disconnect is done, DCD must drop before a new connection can be made (i.e. it will not raise DTR until DCD drops). Remote Support Modem Configuration A-9 Safety Considerations CCITT BIS Mode AP protocol 2 This protocol is CCITT V.22bis. It requires the special cable A1703-63006 which is just like the 92219Q cable with the exception that pin 9 on the computer end is routed to pin 12 (RS) rather than pin 22 (RI). DTR is raised whenever a connection is allowed. RTS follows DSR. A connection is established when DSR is high. CTS can drop for an indenite amount of time without dropping the connection. The card will not send data to the modem when CTS is low. DCD can drop for up to 400ms before the connection is dropped. Once the connection is dropped, DSR, DCD and CTS must all go low before a new connection can be made. RS controls what speed the card sends to the modem. If RS is high, the programmed baud rate is used. If RS is low, half of the programmed baud rate is used. If you use the 92219Q cable, the baud rate will most certainly be half the programmed baud rate, since RI will almost always be down. FS can be programmed to either state via the CA command. Modem Settings (HP Predictive Support) The HP Predictive Support User's Guide for HP 3000 Series 900 (p/n 50779-90012) contains additional information on HP predictive support modem settings. Table A-7 contains a quick reference description of the modem switch settings for autodial modems connected to the LAN/Console port. Note A-10 Some of the settings in Table A-7 are dierent than those described in the rst part of the Appendix. This is true for modems connected to a DTC or manually dialed modems. Please refer to HP Predictive Support on-line help for proper switch settings. Also be aware that the modems listed here are not necessarily recommended or supported as Remote Support Modems. Remote Support Modem Configuration Safety Considerations Table A-7. Predictive Support Modems and Switch Settings Modem Type Switch Settings1 HP 50759A (Support Link) X1, X2, X4, S4, and S8; Down All others; Up Note HP 50759B S2, S3, S4, S7, S8, S9, S12, and S16; Down All others; Up HP 37212A All switches; Open HP 37212B S3, S11, and S12; Up All others; Down Hayes Smartmodem S4, S8, and S10; Down Support Link I Option 1: Code 3 Option 1: Code 2 Option 8: Code 2 Option 15: Code 2 Option 16: Code 2 Option 22: Code 1 for pulse Option 22: Code 2 for tone Option 22: Code 3 for autoselect Option 24: Code 2 Support link II Option 1: Code 3 Option 1: Code 2 Option 8: Code 2 Option 15: Code 2 Option 16: Code 2 Option 22: Code 1 for autoselect Option 22: Code 2 for tone Option 22: Code 3 for pulse The switch settings are for autodial modems connected to the LAN/Console port. 1 Remote Support Modem Configuration A-11 ">
/
Изтегляне
Само приятелско напомняне. Можете да видите документа точно тук. Но най-важното е, че нашият AI вече го е прочел. Той може да обясни сложни неща на прости термини, да отговори на вашите въпроси на всеки език и да ви помогне бързо да навигирате дори в най-дългите или най-сложните документи.
Реклама