Comtech EFData SMS 301 Redundancy Switch, RS 301 Remote Switch, SDM 300, SDM 300A, SDM 2020 Satellite Modem Installation and Operation Manual
Below you will find brief information for Redundancy Switch SMS 301, Remote Switch RS 301, Satellite Modem SDM 300, Satellite Modem SDM 300A, Satellite Modem SDM 2020. The Redundancy Switch SMS 301, Remote Switch RS 301, Satellite Modem SDM 300, Satellite Modem SDM 300A, Satellite Modem SDM 2020 are designed to provide redundancy for one prime modem using one identical backup modem. Full Monitor and Control (M&C) functions are supported by an integrated microprocessor system. The M&C system is designated to maintain the 1:1 switch configuration settings in non-volatile memory for at least one year without prime power. Remote control is provided by an EIA-485 or EIA-232 interface located on the rear panel of the chassis.
Advertisement
Advertisement
SMS-301 Redundancy Switch Installation and Operation Manual Part Number MN/SMS301.IOM Revision 3 SMS-301 Redundancy Switch Installation and Operation Manual Comtech EFData is an ISO 9001 Registered Company. Part Number MN/SMS301.IOM Revision 3 November 19, 1999 Copyright © Comtech EFData, 2000. All rights reserved. Printed in the USA. Comtech EFData, 2114 West 7th Street, Tempe, Arizona 85281 USA, (480) 333-2200, FAX: (480) 333-2161. Customer Support Contact the Comtech EFData Customer Support Department for: • Product support or training • Information on upgrading or returning a product • Reporting comments or suggestions concerning manuals A Customer Support representative may be reached at: Comtech EFData Attention: Customer Support Department 2114 West 7th Street Tempe, Arizona 85281 USA (480) 333-2200 (Main Comtech EFData Number) (480) 333-4357 (Customer Support Desk) (480) 333-2161 FAX or, E-Mail can be sent to the Customer Support Department at: [email protected] Contact us via the web at www.comtechefdata.com. 1. To return a Comtech EFData product (in-warranty and out-of-warranty) for repair or replacement: 2. Request a Return Material Authorization (RMA) number from the Comtech EFData Customer Support Department. 3. Be prepared to supply the Customer Support representative with the model number, serial number, and a description of the problem. 4. To ensure that the product is not damaged during shipping, pack the product in its original shipping carton/packaging. 5. Ship the product back to Comtech EFData. (Shipping charges should be prepaid.) For more information regarding the warranty policies, see Warranty Policy, p. xi. ii Rev. 3 Table of Contents CHAPTER 1. INTRODUCTION.................................................................................. 1–1 1.1 Description............................................................................................................................................... 1–2 1.1.1 Description (Standard Configuration) ............................................................................................... 1–2 1.1.2 Description (With RS-301 Option) ................................................................................................... 1–3 1.1.3 Board List.......................................................................................................................................... 1–4 1.2 Front Panel .............................................................................................................................................. 1–5 1.3 Specifications ........................................................................................................................................... 1–6 CHAPTER 2. INSTALLATION ................................................................................... 2–1 2.1 Unpacking ................................................................................................................................................ 2–1 2.2 System Installation .................................................................................................................................. 2–2 2.3 External Connections.............................................................................................................................. 2–3 2.3.1 Remote Switch Control (J1) (RS-301 Option) .................................................................................. 2–5 2.3.2 Data I/O Connections ........................................................................................................................ 2–6 2.3.2.1 Data I/O Connector (J1, J2, J3), 50-Pin (PL/5951) ....................................................................... 2–6 2.3.2.2 Data I/O Connector (J1, J2, J3), 37-Pin (PL/5952) ........................................................................ 2–7 2.3.2.3 Data I/O Connector (J1, J2, J3), 25-Pin (PL/6026) ....................................................................... 2–8 2.3.2.4 Data I/O (J1, J2, J3) 37-Pin (PL/6201-1) ...................................................................................... 2–9 2.3.2.5 Data I/O Connector (J1, J2, J3) 37-Pin (PL/6201-2)................................................................... 2–10 2.3.2.6 100 Pin interface (RS-301 Option) (PL/6542/PL/6627).............................................................. 2–11 2.3.3 Transmit IF Connectors (J4, J5, J6) ................................................................................................ 2–13 2.3.4 RX IF Connectors (J7, J8, J9) ......................................................................................................... 2–13 2.3.5 Remote Control Interface Connector (J10) ..................................................................................... 2–14 2.3.6 Prime Power .................................................................................................................................... 2–15 2.3.6.1 AC Power (J11 and J12).............................................................................................................. 2–15 2.3.6.2 DC Power (J11 and J12) (Optional) ............................................................................................ 2–15 2.3.7 Switch/Modem Communications Interface Connector (J13) .......................................................... 2–16 2.3.8 Status/Fault (J14) ............................................................................................................................ 2–17 2.3.9 IF Connections: Transmit and Receive ........................................................................................... 2–17 2.3.10 Ground ............................................................................................................................................ 2–17 Rev. 3 iii Preface SMS-301 Redundancy Switch CHAPTER 3. OPERATION .........................................................................................3-1 3.1 Configuration ........................................................................................................................................... 3-1 3.2 Setup and Configuration ......................................................................................................................... 3-2 3.2.1 Utility System..................................................................................................................................... 3-3 3.2.2 Configuration ..................................................................................................................................... 3-3 3.2.2.1 Prime .............................................................................................................................................. 3-3 3.2.2.2 Backup ........................................................................................................................................... 3-4 3.2.2.3 Operation Mode ............................................................................................................................. 3-5 3.3 Faults......................................................................................................................................................... 3-5 3.4 Front Panel Keypad ................................................................................................................................. 3-6 3.5 Menu System ............................................................................................................................................ 3-7 3.5.1 Front Panel Menus ............................................................................................................................. 3-9 3.5.1.1 Configuration Switch Control Menu ............................................................................................ 3-11 3.5.1.2 Configuration System Menu ........................................................................................................ 3-13 3.5.1.3 Configuration Save Menu ............................................................................................................ 3-15 3.5.1.4 Configuration Recall Menu .......................................................................................................... 3-16 3.5.1.5 Monitor Menu .............................................................................................................................. 3-17 3.5.1.6 Faults/Alarms ............................................................................................................................... 3-19 3.5.1.7 Stored Faults/Alarms.................................................................................................................... 3-21 3.5.1.8 Utility System............................................................................................................................... 3-23 3.5.1.9 Utility Modem Control................................................................................................................. 3-27 CHAPTER 4. THEORY OF OPERATION ...................................................................4-1 4.1 Monitor and Control (M&C) .................................................................................................................. 4-1 4.1.1 Theory of Operation ........................................................................................................................... 4-2 4.2 SMS-301 Data Interface .......................................................................................................................... 4-3 4.2.1 IBS, IDR, ASYNC, or D&I (J1, J2, J3), 50-Pin (PL/5951) ............................................................... 4-3 4.2.2 EIA-422/-449, G.703, or V.35 (J1, J2, J3), 37-Pin (PL/5952) ........................................................... 4-3 4.2.3 LVDS-DVB TX, (J1, J2, J3), 37-Pin, (PL/6201-1)............................................................................ 4-3 4.2.4 EIA-422/DVB TX (J1, J2, J3), 25-Pin (PL/6026).............................................................................. 4-4 4.3 Remote Switch (RS-301) Option ............................................................................................................. 4-5 CHAPTER 5. MAINTENANCE....................................................................................5-1 5.1 Software Revisions ................................................................................................................................... 5-1 5.2 Test Points and LEDs............................................................................................................................... 5-3 5.3 Fault Isolation........................................................................................................................................... 5-4 iv Rev. 3 SMS-301 Redundancy Switch Preface APPENDIX A. REMOTE CONTROL OPERATION ................................................... A-1 A.1 General..................................................................................................................................................... A-1 A.2 Message Structure................................................................................................................................... A-2 A.2.1 Start Character................................................................................................................................... A-2 A.2.2 Device Address ................................................................................................................................. A-3 A.2.3 Command/Response.......................................................................................................................... A-3 A.2.4 End Character.................................................................................................................................... A-4 A.3 Configuration Commands/Responses.................................................................................................... A-5 A.4 Modem Communications Configuration Commands/Responses........................................................ A-6 A.5 System Commands/Responses ............................................................................................................... A-7 A.6 Status Commands/Responses ................................................................................................................. A-8 A.7 Fault Summary Status Commands/Responses ..................................................................................... A-9 A.8 Stored Faults.......................................................................................................................................... A-10 APPENDIX B. SDM-300/-300A SYSTEM INSTALLATIONS.................................... B–1 B.1 System Installation ..................................................................................................................................B–1 B.1.1 System Installation (Standard Configuration) ...................................................................................B–2 B.1.2 System Installation (RS-301 Switch Installed)..................................................................................B–5 B.1.3 Connect System Installation with RS-301 Switch.............................................................................B–6 APPENDIX C SDM-2020 SYSTEM INSTALLATIONS .............................................. C–1 C.1 Installation Options.................................................................................................................................C–1 C.1.1 Connect Low Voltage Differential Signal Interface (Optional) ........................................................C–1 C.1.1.1 Description ....................................................................................................................................C–1 C.1.1.2 Connect to SDM-2020 Modulator with LVDS Interface ..............................................................C–3 C.1.2 Connect to SDM-2020 Satellite Modulator with EIA-422 Interface.................................................C–4 C.1.2.1 Description ....................................................................................................................................C–4 C.1.2.2 Connect to SDM-2020 Modulator with EIA-422 Interface...........................................................C–5 C.1.3 Connect to SDM-2020 Satellite Modulator with EIA-422 DVB TX Interface ................................C–6 C.1.3.1 Description ....................................................................................................................................C–6 C.1.3.2 Connect to SDM-2020 Modulator with EIA-422 DVB TX Interface ...........................................C–7 C.1.4 Connect to SDM-2020 Satellite Modulator with EIA-422 (DVB) TX Interface (100 Mbit/s) .........C–9 C.1.4.1 Description ....................................................................................................................................C–9 C.1.4.2 Connect to SDM-2020 Modulator with EIA-422 DVB TX Interface .........................................C–10 C.1.5 Connect to SDM-2020 Satellite Modulator I/O Connector, 25-Pin Interface .................................C–12 C.1.5.1 Description ..................................................................................................................................C–12 C.1.5.2 Connect to SDM-2020 Modulator with I/O Connector, 25-Pin Interface ...................................C–12 GLOSSARY ................................................................................................................g–1 INDEX .......................................................................................................................... i–1 Rev. 3 v Preface SMS-301 Redundancy Switch Figures Figure 1-1. SMS-301 ........................................................................................................................................... 1–1 Figure 1-2. System Block Diagram (Standard Configuration) ............................................................................ 1–2 Figure 1-3. System Block Diagram (With RS-301 Option)................................................................................. 1–3 Figure 2-1. SMS-301 Rear Panel Configurations ................................................................................................ 2–3 Figure 3-1. SMS-301 Front Panel View ............................................................................................................... 3-1 Figure 3-2. Keypad ............................................................................................................................................... 3-6 Figure 3-3. Main Menu......................................................................................................................................... 3-9 Figure 3-4. Configuration Switch Control Menu................................................................................................ 3-10 Figure 3-5. Configuration System Menu ............................................................................................................ 3-12 Figure 3-6. Configuration Save Menu ................................................................................................................ 3-15 Figure 3-7. Configuration Recall Menu.............................................................................................................. 3-16 Figure 3-8. Monitor Menu .................................................................................................................................. 3-17 Figure 3-9. Faults/Alarms Menu......................................................................................................................... 3-18 Figure 3-10. Stored Faults/Alarms Menu ........................................................................................................... 3-20 Figure 3-11. Utility System Menu ...................................................................................................................... 3-22 Figure 3-12. Utility Modem Control Menu ........................................................................................................ 3-26 Figure B-1. System Installation (Standard Configuration) ..................................................................................B–3 Figure B-2. System Installation (RS-301 Installed).............................................................................................B–6 Figure C-1. Connect to SDM-2020 Modulator with LVDS Interface .................................................................C–3 Figure C-2. Connect to SDM-2020 Modulator with EIA-422 Interface..............................................................C–5 Figure C-3. Connect to SDM-2020 Modulator with EIA-422 (DVB) TX Interface (18 Mbit/s Serial Data).....C–8 Figure C-4. Connect to SDM-2020 Modulator with EIA-422 (DVB) TX Interface (100 Mbit/s Parallel Data)C–11 Figure C-5. Connect to SDM-2020 Modulator with I/O Connector, 25-Pin Interface ......................................C–13 vi Rev. 3 SMS-301 Redundancy Switch Preface Tables Table 1-1. Board List Table 1-2. LED Status Indictors Table 1-3. 1:1 Switch Specifications Table 2-1. Rear Panel Connectors (Standard Configuration) Table 2-2. Rear Panel Connectors (With RS-301 Option) Table 2-3. Switch Control Interface Signals Table 2-4. Data I/O Connector, 50-Pin Table 2-5. Data I/O Connectors, 37-Pin Table 2-6. Connector Assignments, 25-Pin Table 2-7. Connector Assignments, 37-Pin Table 2-8. Connector Assignments, 37-Pin Table 2-9. Data I/O Connector, 100-Pin Table 2-10. Remote Control Interface Connector Pinout Data (J10) Table 2-11. AC Power (J11 and J12) Table 2-12. DC Prime Power (J11 and J12) Table 2-13. Switch/Modem Communications Interface Connector (J13) Table 2-14. Status/Faults (J14) Pinout Assignments Table 3-1. Default Configuration Parameters Table 3-2. Keypad Functions Table 4-1. Remote Switch (RS-301) Connectors Table 4-2. Tributary 1 Data (J1) Table 4-3. Tributary 2 Data (J2) Table 4-4. Tributary 3 Data (J3) Table 4-5. Tributary 4 Data (J4) Table 4-6. Tributary 5 Data (J5) Table 4-7. Tributary 6 Data (J6) Table 4-8. Tributary 7 Data (J7) Table 4-9. Tributary 8 Data (J8) Table 4-10. AUX Data (J9) Table 4-11. Modem A Data (J14) Table 4-12. Modem B Data (J15) Table 4-13. Switch Control Interface (J16) Table 5-1. LED Functions Table 5-2. Fault Isolation, 1:1 Switch Table B-1. Standard Configuration Cabling Table B-2. RS-301 Configuration Cabling Table C-1. LVDS/DVB Specifications Table C-2. EIA-422/EIA-530 Specifications Table C-3. EIA-422/EIA-530 Specifications Table C-4. Cable Pin Assignments (CA/6217) Table C-5. Cable Pin Assignments (CA/6217) Table C-6. Pin Assignments, 25-Pin Rev. 3 1–4 1–5 1–6 2–4 2–4 2–5 2–6 2–7 2–8 2–9 2–10 2–11 2–14 2–15 2–15 2–16 2–17 3-2 3-6 4-5 4-6 4-6 4-6 4-7 4-7 4-7 4-8 4-8 4-8 4-9 4-10 4-11 5-3 5-4 B–2 B–5 C–2 C–4 C–6 C–7 C–10 C–12 vii Preface SMS-301 Redundancy Switch Overview of Changes to Previous Edition This revision supersedes part number MN/SMS301.IOM Rev. 2, dated February 6, 1998 A summary of the changes made for Rev. 3 includes: • Various non-technical cosmetic changes (formatting, etc.). • Add new EMC directive. • Revised Table 1-1 Board List. • Revised Table 1-3 to include Control Box Extender Card Connector. • Revised paragraph 2.2 to relocatecabling instructions to appendices. • Paragraph 2.3, Rearranged section. • Added Standard Configuration to Figure 2-1. • Added Table 2-1 to reflect standard configuration and renumbered Table 2-2 as RS-301 Connectors. • Reidentified paragrapgh 2.3.1 as RS-301 option. • Relocated different installtion options from Section 2 to appendices. • Updated menus to reflect version 1.1.6. • Deleted Sections 4.6 and 4.7. Data relocated to Chapter 2. • Revised Chapter 4, to rearrange data interfaces. • Revised Appendix A to reflect FW/6055-1E. • Added Appendix B to reflect SDM-300/-300A cabling. • Added Appendix C to reflect SDM-2020M cabling. About this Manual This manual provides installation and operation information for the Comtech EFData SMS-301 redundancy switch. This is a technical document intended for earth station engineers, technicians, and operators responsible for the operation and maintenance of the SMS-301. Conventions and References Cautions and Warnings CAUTIO N CAUTION indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. CAUTION may also be used to indicate other unsafe practices or risks of property damage. WARNING indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. WARNIN G viii Rev. 3 SMS-301 Redundancy Switch Preface Metric Conversion Metric conversion information is located on the inside back cover of this manual. This information is provided to assist the operator in cross-referencing English to Metric conversions. Recommended Standard Designations Recommended Standard (RS) Designations have been superseded by the new designation of the Electronic Industries Association (EIA). References to the old designations are shown only when depicting actual text displayed on the screen of the unit (RS-232, RS485, etc.). All other references in the manual will be shown with the EIA designations (EIA-232, EIA-485, etc.) only. Trademarks Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Reporting Comments or Suggestions Concerning this Manual Comments and suggestions regarding the content and design of this manual will be appreciated. To submit comments, please contact the Comtech EFData Customer Support Department. EMC Compliance EN55022 Compliance This equipment meets EN5022. This is a Class A product. In a domestic environment, it may cause radio interference in which the user may be required to take adequate measures. Rev. 3 ix Preface SMS-301 Redundancy Switch Federal Communications Commission (FCC) This equipment has been tested and found to comply with the limits for a Class A digital device, following Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communication. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Note: To ensure compliance, properly shielded cables for DATA I/O shall be used. More specifically, these cables shall be doubled-shielded from end-to-end, ensuring a continuous shield. Low Voltage Directive (LVD) The following information is applicable for the European Low Voltage Directive (EN60950): <HAR> ! Type of power cord required for use in the European Community. CAUTION: Double-pole/Neutral Fusing. ACHTUNG: Zweipolige bzw. Neutralleiter-Sicherung. International Symbols: Alternating Current. Fuse. Safety Ground. Chassis Ground. Note: 1. Applicable testing is routinely performed as a condition of manufacturing on all units to ensure compliance with requirements of EN60950 for Safety. x Rev. 3 SMS-301 Redundancy Switch Preface Warranty Policy This Comtech EFData product is warranted against defects in material and workmanship for a period of one year from the date of shipment. During the warranty period, Comtech EFData will, at its option, repair or replace products that prove to be defective. For equipment under warranty, the customer is responsible for freight to Comtech EFData and all related custom, taxes, tariffs, insurance, etc. Comtech EFData is responsible for the freight charges only for return of the equipment from the factory to the customer. Comtech EFData will return the equipment by the same method (i.e., Air, Express, Surface) as the equipment was sent to Comtech EFData. Limitations of Warranty The foregoing warranty shall not apply to defects resulting from improper installation or maintenance, abuse, unauthorized modification, or operation outside of environmental specifications for the product, or, for damages that occur due to improper repackaging of equipment for return to Comtech EFData. No other warranty is expressed or implied. Comtech EFData specifically disclaims the implied warranties of merchantability and fitness for particular purpose. Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies. Comtech EFData shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. Disclaimer Comtech EFData has reviewed this manual thoroughly in order that it will be an easy-touse guide to your equipment. All statements, technical information, and recommendations in this manual and in any guides or related documents are believed reliable, but the accuracy and completeness thereof are not guaranteed or warranted, and they are not intended to be, nor should they be understood to be, representations or warranties concerning the products described. Further, Comtech EFData reserves the right to make changes in the specifications of the products described in this manual at any time without notice and without obligation to notify any person of such changes. If you have any questions regarding your equipment or the information in this manual, please contact the Comtech EFData Customer Support Department. Rev. 3 xi Preface SMS-301 Redundancy Switch This page is intentionally blank. xii Rev. 3 1 Chapter 1. INTRODUCTION This manual describes the SMS-301 redundancy switch, referred to in this manual as the “1:1 switch” (Figure 1-1). Figure 1-1. SMS-301 Rev. 3 1–1 Introduction SMS-301 Redundancy Switch 1.1 Description 1.1.1 Description (Standard Configuration) The 1:1 switch is a fully automated protection switch for Comtech EFData satellite modems, providing redundancy for one prime modem using one identical backup modem. Common interfaces are provided for user data terminal equipment and uplink/downlink RF equipment, as well as the primary and redundant (backup) modems. The integrated uplink 1:1 switch and downlink splitter operate at IF frequencies in the range of 50 to 180 MHz. Full Monitor and Control (M&C) functions are supported by an integrated microprocessor system. The M&C system is designated to maintain the 1:1 switch configuration settings in non-volatile memory for at least one year without prime power. Note: While 1:1 switch prime power is not applied, the default connections are to Modem A. Remote control is provided by an EIA-485 or EIA-232 interface located on the rear panel of the chassis. The rear panel also is the location for all external interconnections. The 1:1 switch is enclosed in a single unit, 19-inch (48.3 cm) rack-mounted chassis. Figure 1-2 illustrates the system block diagram. T R A N SM IT IF MODEM A R E C E IV E IF B A S EB A N D D ATA T X/R X J2 J5 J9 1 FO R 1 SW ITCH J1 3 M O D E M R EM O T E S P LIT TE R J1 B A S EB A N D D ATA TO /F R O M C U S TO M E R J8 R E C E IV E IF 50 TO 18 0 M H z F R O M D O W N C O N V E RTE R J4 T R A N SM IT IF 50 TO 18 0 M H z TO U P C O N VE RT E R E IA -4 85 S W IT C H M &C LO G IC J1 4 S TATU S /FA U LTS R E M O TE CONTROL J1 0 E IA -2 32 O R EIA-48 5 J3 J6 J7 T R A N SM IT IF MODEM A R E C E IV E IF B A S EB A N D D ATA T X/R X H O T T E R M IN A L OR COMPUTER Figure 1-2. System Block Diagram (Standard Configuration) 1–2 Rev. 3 SMS-301 Redundancy Switch 1.1.2 Introduction Description (With RS-301 Option) The 1:1 switch, when used with the RS-301 Remote Switch, is a fully-automated protection switch designed for use with the Comtech EFData SDM-300/-300A Satellite Modem that are equipped with the 8-Channel MUX option. It provides redundancy for the one prime modem using identical backup satellite modem. The 1:1 switch provides common interfaces for the RF uplink and downlink equipment. The integrated uplink 1:1 switch and downlink splitter operate at IF frequencies in the range of 50 to 180 MHz. The RS-301 Remote Switch is a separate 19-inch (48.3 cm) rack-mounted chassis. It is controlled by the 1:1 switch, and provides redundancy for the data interface between the primary modem, backup modem, and customer equipment. The front panel provides convenient access to eight tributary data channels (EIA-232 and EIA-422 clock and data) and one auxiliary data channel. Figure 1-3 illustrates the system block diagram. Note: The default connections are to Modem A. S D M -300 / 300A T R A N S M IT IF M OD EM A R E C E IV E IF M O D E M A D ATA (8 T R IB & A U X ) B A S E B A N D D ATA T X /R X J5 N O T E : J7, J8 , A N D J9 A R E N O T U SE D . J9 J1 4 1 FO R 1 S W IT C H S P L IT T E R J1 3 J1 4 M ODEM REM OTE E IA -4 8 5 J1 T R IB 1 D ATA J8 J2 T R IB 2 D ATA S W IT C H M&C L O G IC CO NTROL BUS E XTEN D E R CARD S TAT U S FA U LT S S W IT C H CO NTROL J3 T R IB 3 D ATA J1 6 J4 T R IB 4 D ATA J5 T R IB 5 D ATA REM OTE CO NTROL J1 0 J1 J4 J6 T R A N S M IT IF 5 0 T O 1 8 0 M H z TO U P C O N V E R TE R J6 T R IB 6 D ATA J7 T R IB 7 D ATA J8 T R IB 8 D ATA J7 E IA -2 3 2 O R E IA -4 8 5 J9 A U X D ATA S D M -300 / 300A M OD EM B T R A N S M IT IF H O S T T E R M IN A L OR COM PUTER R E C E IV E IF B A S E B A N D D ATA T X /R X M O D E M B D ATA (8 T R IB & 1 A U X ) R S -3 01 REMOTE S W IT C H J1 5 Figure 1-3. System Block Diagram (With RS-301 Option) Rev. 3 1–3 Introduction 1.1.3 SMS-301 Redundancy Switch Board List The following boards, listed in Table 1-1, can be installed in the SMS-301, depending on the configuration. Table 1-1. Board List Board Type M&C, 75Ω M&C, 50Ω IBS, IDR, ASYNC, D&I, 50-pin Data, I/O (J1, J2, J3) EIA-422/-449, G.703, V.35, 37-pin Data I/O (J1, J2, J3) LVDS-DVB TX, 37-pin Interface EIA-422/DVB TX, 37-pin Interface EIA-232/-422/-530, V.35, G.703 25-pin Data, I/O (J1, J2, J3) 100-Pin Interface (RS-301 only) 1–4 Drawing # PL/5950-1 PL/5950-2 PL/5951 PL/5952 PL/6201-1 PL/6201-2 PL/6026 PL/6592 PL/6627 Rev. 3 SMS-301 Redundancy Switch 1.2 Introduction Front Panel The front panel of the chassis is a local user interface used for control and status monitoring of the switching system. This local user interface consists of the following: • • • Keypad Backlit LED display LED status indicators (Table 1-2) Table 1-2. LED Status Indictors Function Demodulator A On-Line Demodulator B On-Line Modulator A On-Line Modulator B On-Line Transmit Fault Receive Fault System Fault Stored Fault Power Supply 1 Power Supply 2 Auto Mode Manual Mode Rev. 3 Color Green Green Green Green Red Red Red Yellow Green Green Green Yellow 1–5 Introduction 1.3 SMS-301 Redundancy Switch Specifications Refer to Table 1-3 for the 1:1 switch specifications. Table 1-3. 1:1 Switch Specifications Data Interface Switch: Modem A, I/O Modem B, I/O Common, I/O Control Bus Extender Card IF Uplink Switch: IF Downlink Splitter: Local User Interface Front Panel Status LEDs Connector type: 25-pin D-sub, 37-pin D-sub 50-pin D-sub 100-pin D-sub Connector Type: 37-pin D-sub (Remote Switch) Connector type: BNC Impedance: 75Ω (50Ω optional) Return loss: ≥ 18 dB Switched input to output loss: < 1.5 dB Frequency response: 50 to 180 MHz IF input to input isolation: > 60 dB Connector type: BNC Impedance: 75Ω (50Ω optional) Return loss: ≥ 18 dB Splitter loss, input to outputs: < 4.0 dB Output balance: ± 0.5 dB Frequency response: 50 to 180 MHz Front Panel: Keypad: 6 button (enter, clear, left, right, up, down arrows) • Display: backlit LCD, 2 lines by 16 characters • Operational mode: • Manual (Yellow) • Automatic (Green) Switch faults: • TX (Red) • RX (Red) • System (Red) • Stored (Yellow) On-line/Fault Status Modulator On-line Demodulator On-line Switch Fault Controller Fault Spare Remote Control 1–6 On-line Status: • Modulator A (Green) • Modulator B (Green) • Demodulator A (Green) • Demodulator B (Green) Rear panel, 15-pin D-sub female Form C relay Form C relay Form C relay Form C relay Form C relay Interface type: EIA-485/EIA-232 (local selectable) Connector: 9-pin D-sub Protocol: Addressable (see remote control protocol) Rev. 3 SMS-301 Redundancy Switch Introduction Table 1-3. 1:1 Switch Specifications (Continued) Parameters Controlled/Monitored Configuration Retention Switch to Modem Communications Prime Power Size Weight Operating Temperature Humidity EMI Rev. 3 Operation mode: Automatic or manual Switching mode: Independent or dependent mod/demod Modulator on-line delay Demodulator on-line delay Modem on-line: A or B (dependent mode) Modulator on-line: A or B (independent mode) Demodulator on-line: A or B (independent mode) Remote configuration (local only): EIA-232 or EIA-485, address, baud, parity, bits per word Remote mode (Switch) Clear stored faults Current faults Stored faults Switch status Firmware Time/date Equipment type Store/recall multiple switch configurations Remote access to modulator/demodulator status Modem configuration copy to opposite modem Will maintain configuration for at least one year without prime power Interface type: EIA-485 (2-wire) Connector: 9-pin D-sub Protocol: Addressable (see remote control protocol, Appendix A) 85 to 264 VAC, 47 to 63 Hz, 30W (redundant inputs) (Optional) 42 to 56 VDC, 40W (redundant inputs) 19 W x 15.2 D x 1.75 H inches (1 RU) (48.3 x 39 x 4.4 cm) < 9 lbs (4 kg) 0° to 50° C (32° to 122° F) < 95%, non-condensing CE Mark Certification 1–7 Introduction SMS-301 Redundancy Switch This page is intentionally left blank. 1–8 Rev. 3 2 Chapter 2. INSTALLATION This chapter provides installation information for the 1:1 switch, including unpacking, inspecting the parts, and external connections. 2.1 Unpacking The 1:1 switch and manual are packaged in pre-formed, reusable cardboard cartons containing foam spacing for maximum shipping protection. To remove the 1:1 switch, proceed as follows: Do not use any cutting tool that will extend greater than 1-inch into the container and cause damage to the 1:1 switch. CAU TIO N 1. Cut the tape at the top of the carton where it is indicated OPEN THIS END. 2. Lift out the cardboard/foam spacer covering the 1:1 switch. 3. Remove the 1:1 switch, manual, and power cords from the carton. 4. Save the packing material for reshipment either back to the factory or to another location. 5. Inspect the equipment for any possible damage incurred during shipment. 6. Check the equipment against the packing list to ensure that the shipment is complete. 7. Refer to Section 2.2 for further system installation instructions. Rev. 3 2–1 Installation 2.2 SMS-301 Redundancy Switch System Installation System installation instructions are dependent on whether or not the 1:1 switch is used with the RS-301 Remote Switch option. • For all switch configurations where the Data I/O is switched internally to the 1:1 switch, refer to Appendix B for standard configuration installation. This configuration is used with the SDM-300/-300A Satellite Modems with 25-pin, 34-pin, 37-pin, and 50-pin Data I/O interfaces. • When the RS-301 Remote Switch option is used and the Data I/O is s witched in a separate unit, refer to Appendix B for installation with RS –301 switch installed. This configuration is used with the SDM-300/-300A Satellite Modem with a 100-pin Data I/O (8-channel Mux). Note: Refer to Appendix C for SDM-2020 cabling instructions to the switch. 2–2 Rev. 3 SMS-301 Redundancy Switch 2.3 Installation External Connections Connections between the 1:1 switch and other equipment are performed through the rear panel connectors. These connectors vary depending on whether the Remote Switch (RS301) is used. • Refer to Table 2-1 for the connector list when the Data I/O is switched internal to the 1:1 switch. • When the 1:1 switch is used with the Remote Switch (RS-301) option, refer to Table 2-2. DE MOD J1 REM O TE SW IT CH CON TROL J9 A MOD J8 RX IF J7 B J4 TX IF J5 A J6 B ! 100 TO 240 V 1.5 A 50 TO 60 Hz AC2 J12 T2A , 250V AC 1 J11 J14 J10 RE MOTE CON TRO L STAT US/FAULT S MOD EM COM J13 Rear Panel (Standard Configuration) TRIB 1 DATA TRIB 2 DATA TRIB 3 DATA TRIB 4 DATA TRIB 5 DATA TRIB 6 DATA TRIB 7 DATA TRIB 8 DATA AUX J1 J2 J3 J4 J5 J6 J7 J8 J9 R S-301 Rear Panel (With RS-301 Option) Figure 2-1. SMS-301 Rear Panel Configurations Rev. 3 2–3 Installation SMS-301 Redundancy Switch Table 2-1. Rear Panel Connectors (Standard Configuration) Name DATA COM DATA A DATA B TX IF COM TX IF A TX IF B RX IF B RX IF COM RX IF A REMOTE CONTROL AC POWER SW/MODEM COMM STATUS/FAULTS GND Ref Des J1 J2 J3 J4 J5 J6 J7 J8 J9 J10 J11/J12 J13 J14 GND Connector Type 50/37/25-pin D 50/37/25-pin D 50/37/25-pin D BNC BNC BNC BNC BNC BNC 9-pin D IEC 9-pin D 15-pin D #10-32 stud Function Common Data Interface Modem A Data Interface Modem B Data Interface Common TX IF Output Modem A TX IF Input Modem B TX IF Input Modem B RX IF Output Common RX IF Input Modem A RX IF Output Remote Command Interface AC Power Input Modem A/B Remote Switch Status (Form C relay) Ground Table 2-2. Rear Panel Connectors (With RS-301 Option) Name REMOTE SWITCH CONTROL TX IF COM TX IF A TX IF B RX IF B RX IF COM RX IF A REMOTE CONTROL AC POWER DC POWER (Optional) SW/MODEM COMM STATUS/FAULTS GND Ref Des J1 Connector Type 37-pin D J4 J5 J6 J7 J8 J9 J10 J11/J12 J11/J12 J13 J14 GND BNC BNC BNC BNC BNC BNC 9-pin D IEC Terminal Block 9-pin D 15-pin D #10-32 stud Function RS-301 Control Signals, Power, and Ground Common TX IF Output Modem A TX IF Input Modem B TX IF Input Modem B RX IF Output Common RX IF Input Modem A RX IF Output Remote Command Interface AC Power Input DC Power Input Modem A/B Remote Switch Status (form C relay) Ground Note: The use of each connector is described in the following paragraphs. 2–4 Rev. 3 SMS-301 Redundancy Switch 2.3.1 Installation Remote Switch Control (J1) (RS-301 Option) For applications using the Remote Switch (RS-301) option, the connector type is a 37-pin D subminiature. Refer to Table 2-3 for the 37-pin connector pin assignments. Table 2-3. Switch Control Interface Signals Pin No. 1 20 2 21 3 22 4 23 5 24 6 25 7 26 8 27 9 28 10 29 11 30 12 31 13 32 14 33 15 34 16 35 17 36 18 37 19 Rev. 3 Name SCL SDA Spare 11 Spare 10 Spare 9 Spare 8 Spare 7 Spare 6 Spare 5 Spare 4 Spare 3 Spare 2 Spare 1 DMDONL MODONL /B_DF /A_DF /B_MF /A_MF ID_5 ID_4 ID_3 ID_2 ID_1 GND GND GND GND GND -12V -12V +12V +12V +5V +5V +5V +5V Function Serial Clock Serial Data No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection Demod Online Mod Online Modem B Demod Fault Modem A Demod Fault Modem B Mod Fault Modem A Mod Fault Interface Board ID Interface Board ID Interface Board ID Interface Board ID Interface Board ID Ground Ground Ground Ground Ground -12VDC -12VDC +12VDC +12VDC +5VDC +5VDC +5VDC +5VDC 2–5 Installation 2.3.2 SMS-301 Redundancy Switch Data I/O Connections The 1:1 switch data interface is dependent upon the installed switchboard. These are described in the following sections. 2.3.2.1 Data I/O Connector (J1, J2, J3), 50-Pin (PL/5951) Note: For ASYNC, IBS, IDR, and D&I applications. In order to maintain compatibility with various Comtech EFData breakout panels, the 50pin D subminiature connector has the assignments shown in Table 2-4, depending upon the current operating mode. Table 2-4. Data I/O Connector, 50-Pin 50-Pin D Connector Pin # 34 18 36 20 35 19 37 38 21 22 4 5 39 40 23 24 6 7 45 29 44 12 13 14 15 17 16 50 3 49 33 1, 2 2–6 IDR G.703 SDA In G.703 SDB In G.703 RDA Out G.703 RDB Out EIA-422 ExtClkA In EIA-422 ExtClkB In EIA-422 8k TXDA In EIA-422 8k TXDB In EIA-422 8k TClkA Out EIA-422 8k TClkB Out EIA-422 TXOctA In EIA-422 TXOctB In EIA-422 8k RXDA Out EIA-422 8k RXDB Out EIA-422 8k RClkA Out EIA-422 8k RClkB Out EIA-422 RXOctA Out EIA-422 RXOctB Out Aud1-A In (or 64SDA) Aud1-B In (or 64SDB) BWO4_NO BWAI 1 BWAI 2 BWAI 3 BWAI 4 Def Maint Alrm Demod Fault C Demod Fault NO AGC Out MF (Open Collector) DF (Open Collector) Ground IBS G.703 SDA In G.703 SDB In G.703 RDA Out G.703 RDB Out V.35/EIA-422 EXCA In V.35/EIA-422 EXCB In V.35/EIA-422 SD-A In V.35/EIA-422 SD-B In V.35/EIA-422 ST-A Out V.35/EIA-422 ST-B Out ESC TXDA In (EIA-232 only) V.35/EIA-422 RD-A Out V.35/EIA-422 RD-B Out V.35/EIA-422 RT-A Out V.35/EIA-422 RT-B Out ESC RXDA Out (EIA-232 only) V.35/EIA-422 RTS-A V.35/EIA-422 RTS-B SECONDARY_NO V.35/EIA-422 SCTE/TT A V.35/EIA-422 SCTE/TT B EIA-422 TX Oct A EIA-422 TX Oct B AGC Out MF (Open Collector) DF (Open Collector) Async G.703 SDA In G.703 SDB In G.703 RDA Out G.703 RDB Out V.35/EIA-422 EXCA In V.35/EIA-422 EXCB In V.35/EIA-422 SD-A In V.35/EIA-422 SD-B In V.35/EIA-422 ST-A Out V.35/EIA-422 ST-B Out ESC TXDB In (EIA-485 only) ESC TXDA In (EIA-485 & 232) V.35/EIA-422 RD-A Out V.35/EIA-422 RD-B Out V.35/EIA-422 RT-A Out V.35/EIA-422 RT-B Out ESC RXDB Out (EIA-485 only) ESC RXDA Out (EIA-485 & 232) V.35/EIA-422 RTS-A V.35/EIA-422 RTS-B D&I G.703 SDA In G.703 SDB In G.703 RDA Out G.703 RDB Out EIA-422 EXCA In EIA-422 EXCB In G.703 DDO-A Out G.703 DDO-B Out ESC TXD In (EIA-232 only) G.703 IDI-A In G.703 IDI-B In G.703 IDI-B In ESC RXD Out (EIA-232) SECONDARY_NO V.35/EIA-422 SCTE/TT A V.35/EIA-422 SCTE/TT B AGC Out MF (Open Collector) DF (Open Collector) AGC Out MF (Open Collector) DF (Open Collector) Rev. 3 SMS-301 Redundancy Switch 2.3.2.2 Installation Data I/O Connector (J1, J2, J3), 37-Pin (PL/5952) Note: For EIA-422/-449, V.35, and G.703 applications. The 37-pin D subminiature connector pin assignments are shown in Table 2-5. Table 2-5. Data I/O Connectors, 37-Pin Pin # 1 3 4 22 5 23 6 24 7 25 8 26 9 27 11 29 13 31 17 35 16 34 19 20 21 37 EIA-422/-449 SG MF SD-A SD-B ST-A ST-B RD-A RD-B RS-A RS-B RT-A RT-B CS-A CS-B DM-A DM-B RR-A RR-B TT-A TT-B MC-A MC-B SG SG DF SG V.35 SG MF SD-A SD-B ST-A ST-B RD-A RD-B RS-A RS-B RT-A RT-B CS-A CS-B DM-A DM-B RR-A RR-B TT-A TT-B MC-A MC-B SG SG DF SG G.703 SG MF SD-A SD-B Signal Function Signal Ground MOD Fault Send Data Send Timing RD-A RD-B Receive Data Request to Send Receiver Timing Clear to Send Data Mode Receiver Ready Terminal Timing MC-A MC-B SG SG DF SG Master Clock (Input) Signal Ground Signal Ground DEMOD Fault Signal Ground The following shows the jumper configurations for EIA-422/449, V.35, and G.703. EIA-422/449/V.35 JP2 JP3 JP4 JP5 Rev. 3 G.703 JP1 JP6 JP7 JP6 JP9 2–7 Installation 2.3.2.3 SMS-301 Redundancy Switch Data I/O Connector (J1, J2, J3), 25-Pin (PL/6026) Note: For EIA-422/-530, EIA-232, V.35, or G.703 applications, The 25-pin D subminiature connector has the pin assignments shown in Table 2-6. Table 2-6. Connector Assignments, 25-Pin Pin # 3 16 2 14 24 11 15 12 17 9 4 19 5 13 8 10 6 22 20 23 18 21 25 7 1 EIA-422/-530 RD-A RD+B SD-A SD+B TT-A TT+B ST-A ST+B RT-A RT-B RS-A RS+B CS-A CS+B RR-A RR+B DM-A DM+B MC-A MC+B LL DF MF SIGGND SHLD EIA-232 RXD RTS V.35 RD-A RD+B SD-A SD+B SCTE--A SCTE+B SCT-A SCT+B SCR-A SCR-B RTS CTS CTS Clear to Send DCD RLSD Receiver Ready DSR DSR Data Mode MC MC-A MC+B LL DF MF SIGGND SHLD TXD TXC ST RXC LL DF MF SIGGND SHLD G.703 RD-A RD+B SD-A SD+B Signal Function Receive Data Send Data Terminal Timing Send Timing Receiver Timing Request to Send MC-A MC+B Master Clock (input) DF MF SIGGND SHLD Demod Fault Mod Fault Signal Ground The following shows the jumper configurations for EIA-422/530. EIA-422/-530 J6 J7 J8 J9 J14 J15 J17 J18 J20 J21 J22 J26 2–8 V.35 J6 J7 J8 J9 J14 J15 J16 J18 J20 J21 J22 J26 EIA-232 J19 J23 J24 J25 J27 J28 J29 J30 J17 G.703 J5 J10 J11 J12 J13 J14 J18 J20 J21 J22 J26 Rev. 3 SMS-301 Redundancy Switch 2.3.2.4 Installation Data I/O (J1, J2, J3) 37-Pin (PL/6201-1) Note: For EIA-422/LVDS DVB (Serial or Parallel) Interface applications. The 37–pin D subminiature connector has the pin assignments shown in Table 2-7. Table 2-7. Connector Assignments, 37-Pin Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Rev. 3 Signal Function/Name Signal GND REF CLK/GND B MF NC NC D0B D1 B D2 B D3 B D4 B D5 B D6 B D7 B Valid B SYNC B NC NC NC CLK A NC REF CLK/GND A DF NC NC D0 A D1 A D2 A D3 A D4 A D5 A D6 A D7 A Valid A SYNC A NC NC CLK B Comment Mod/Demod REF CLK Mod Fault No Connection No Connection Data Data Data Data Data Data Data Data Valid SYNC No Connection No Connection No Connection Clock No Connection REF CLK Demod Fault No Connection No Connection Data Data Data Data Data Data Data Data Valid SYNC No Connection No Connection Clock 2–9 Installation 2.3.2.5 SMS-301 Redundancy Switch Data I/O Connector (J1, J2, J3) 37-Pin (PL/6201-2) Note: For EIA-422 Serial Interface applications. The 37–pin D subminiature connector has the pin assignments shown in Table 2-8. Table 2-8. Connector Assignments, 37-Pin Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 2–10 Signal Function/Name Signal GND Send Timing (ST-B) Modulator Fault (MF) NC NC NC NC NC Clear To Send (CS-A) NC NC NC Send Data (SD-B) Request To Send (RS-B) NC NC NC NC Terminal Timing (TTA) NC Send Timing (TT-A) NC NC NC NC NC Clear To Send (CS-B) NC NC NC NC Send Data (SD-A) Request To Send (RS-A) NC NC NC Terminal Timing (TT-B) Comment Mod/Demod Modulator Modulator NC NC NC NC NC Modulator NC NC NC Modulator Modulator NC NC NC NC Modulator NC Modulator NC NC NC NC NC Modulator NC NC NC NC Modulator Modulator NC NC NC Modulator Rev. 3 SMS-301 Redundancy Switch 2.3.2.6 Installation 100 Pin interface (RS-301 Option) (PL/6542/PL/6627) The 100-pin connector pin assignments is shown in Table 2-9. Table 2-9. Data I/O Connector, 100-Pin Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Circuit – – – – GND GND DF MF GND RT+B RT–A GND RD+B RD–A GND RR+B RR–A GND MCB MCA GND TC232 8 TD232 8 CTS232 8 TD422B 8 TD422A 8 TC422B 8 TC422A 8 CTS422B8 CTS422A8 GND TC232 7 TD232 7 CTS232 7 TD422B 7 TD422A 7 TC422B 7 TC422A 7 CTS422B7 CTS422A7 GND TC232 6 TD232 6 CTS232 6 TD422B 6 TD422A 6 TC422B 6 TC422A 6 CTS422B6 CTS422A6 Rev. 3 MUX Data 100-Pin Rear Panel Connector Description Pin # Circuit N/A 51 GND N/A 52 TC232 5 N/A 53 TD232 5 N/A 54 CTS232 5 GROUND 55 TD422B 5 GROUND 56 TD422A 5 DEMOD FAULT 57 TC422B 5 MOD FAULT 58 TC422A 5 GROUND 59 CTS422B 5 RECEIVE TIMING B (+) 60 CTS422A 5 RECEIVE TIMING A (–) 61 GND GROUND 62 TC232 4 RECEIVE DATA B (+) 63 TD232 4 RECEIVE DATA A (–) 64 CTS232 4 GROUND 65 TD422B 4 RECEIVER READY B (+) 66 TD422A 4 RECEIVER READY A (–) 67 TC422B 4 GROUND 68 TC422A 4 MASTER CLOCK B (+) 69 CTS422B4 MASTER CLOCK A (–) 70 CTS422A4 GROUND 71 GND EIA-232, TX CLK , TRIB8 72 TC232 3 EIA-232, TX DAT, TRIB8 73 TD232 3 EIA-232, CTS, TRIB8 74 CTS232 3 EIA-422, TX DATB (+), TRIB8 75 TD422B 3 EIA-422, TX DATA (–), TRIB8 76 TD422A 3 EIA-422, TX CLKB (+), TRIB8 77 TC422B 3 EIA-422, TX CLKA (–), TRIB8 78 TC422A 3 EIA-422, CTSB (+), TRIB8 79 CTS422A3 EIA-422, CTSA (–), TRIB8 80 CTS422A3 GROUND 81 GND EIA-232, TX CLK , TRIB7 82 TC232 2 EIA-232, TX DAT, TRIB7 83 TD232 2 EIA-232, CTS, TRIB7 84 CTS232 2 EIA-422, TX DATB (+), TRIB7 85 TD422B 2 EIA-422, TX DATA (–), TRIB7 86 TD422A 2 EIA-422, TX CLKB (+), TRIB7 87 TC422B 2 EIA-422, TX CLKA (–), TRIB7 88 TC422A 2 EIA-422, CTSB (+), TRIB7 89 CTS422B2 EIA-422, CTSA (–), TRIB7 90 CTS422A2 GROUND 91 GND EIA-232, TX CLK , TRIB6 92 TC232 1 EIA-232, TX DAT, TRIB6 93 TD232 1 EIA-232, CTS, TRIB6 94 CTS232 1 EIA-422, TX DATB (+), TRIB6 95 TD422B 1 EIA-422, TX DATA (–), TRIB6 96 TD422A 1 EIA-422, TX CLKB (+), TRIB6 97 TC422B 1 EIA-422, TX CLKA (–), TRIB6 98 TC422A 1 EIA-422, CTSB (+), TRIB6 99 CTS422B1 EIA-422, CTSA (–), TRIB6 100 CTS422A1 Description GROUND EIA-232, TX CLK , TRIB5 EIA-232, TX DAT, TRIB5 EIA-232, CTS, TRIB5 EIA-422, TX DATB (+), TRIB5 EIA-422, TX DATA (–), TRIB5 EIA-422, TX CLKB (+), TRIB5 EIA-422, TX CLKA (–), TRIB5 EIA-422, CTSB (+), TRIB5 EIA-422, CTSA (–), TRIB5 GROUND EIA-232, TX CLK , TRIB4 EIA-232, TX DAT, TRIB4 EIA-232, CTS, TRIB4 EIA-422, TX DATB (+), TRIB4 EIA-422, TX DATA (–), TRIB4 EIA-422, TX CLKB (+), TRIB4 EIA-422, TX CLKA (–), TRIB4 EIA-422, CTSB (+), TRIB4 EIA-422, CTSA (–), TRIB4 GROUND EIA-232, TX CLK , TRIB3 EIA-232, TX DAT, TRIB3 EIA-232, CTS, TRIB3 EIA-422, TX DATB (+), TRIB3 EIA-422, TX DATA (–), TRIB3 EIA-422, TX CLKB (+), TRIB3 EIA-422, TX CLKA (–), TRIB3 EIA-422, CTSB (+), TRIB3 EIA-422, CTSA (–), TRIB3 GROUND EIA-232, TX CLK , TRIB2 EIA-232, TX DAT, TRIB2 EIA-232, CTS, TRIB2 EIA-422, TX DATB (+), TRIB2 EIA-422, TX DATA (–), TRIB2 EIA-422, TX CLKB (+), TRIB2 EIA-422, TX CLKA (–), TRIB2 EIA-422, CTSB (+), TRIB2 EIA-422, CTSA (–), TRIB2 GROUND EIA-232, TX CLK , TRIB1 EIA-232, TX DAT, TRIB1 EIA-232, CTS, TRIB1 EIA-422, TX DATB (+), TRIB1 EIA-422, TX DATA (–), TRIB1 EIA-422, TX CLKB (+), TRIB1 EIA-422, TX CLKA (–), TRIB1 EIA-422, CTSB (+), TRIB1 EIA-422, CTSA (–), TRIB1 2–11 Installation 2.3.3 SMS-301 Redundancy Switch Transmit IF Connectors (J4, J5, J6) The transmit IF switch connectors are as follows: 2.3.4 • The TX IF output of the prime modem connects to TX IF A. • The TX IF output of the backup modem connects to TX IF B. • TX IF COMM is the transmit IF output connector and connects to the uplink IF equipment. The TX IF output of the on-line modem will be available at this connector. • The characteristic impedance of these BNC connectors is 75Ω (50Ω optional). • If the backup or prime modem is disconnected for any reason, place a 75Ω (50Ω optional) termination on the unused connector for a 75Ω (50Ω optional) system, respectively. RX IF Connectors (J7, J8, J9) The Receive IF splitter connectors are as follows: 2–12 • The RX IF of the prime modem connects to RX IF A and the RX IF of the backup modem connects to RX IF B. • RX IF COM connects to customer-furnished equipment. • The characteristic impedance of these BNC connectors is 75Ω (50Ω optional). • There will be less than 4 dB loss between the common input and the A or B output connectors. • If the backup or prime modem is disconnected for any reason, place a 75Ω (50Ω optional) termination on the unused connector for a 75Ω (50Ω optional) system, respectively. Rev. 3 SMS-301 Redundancy Switch 2.3.5 Installation Remote Control Interface Connector (J10) The remote control interface (J10) connector is described in the following listings. Pinout data is included in Table 2-10. Connector type Signal type 9-pin D subminiature, female EIA-232 or EIA-485, user-selectable Interface connector type: • • • • • EIA-485 (2-wire or 4-wire) EIA-232 (Optional) Baud rate range 150 to 19.2 kbit/s ASCII characters 11 bits per character (maximum): ♦ 1 start bit ♦ 7 information bits, 1 parity bit (odd/even) or 8 information bits, 0 parity bit, 1 stop bit ♦ 2 stop bits Table 2-10. Remote Control Interface Connector Pinout Data (J10) EIA-485 4-Wire Pin # Name 1 GND 2 3 4 +TX 5 -TX 6 7 8 +RX 9 -RX EIA-232 2-Wire Name +TX/+RX -TX/-RX +RX/+TX -RX/-TX Pin # 1 2 3 4 5 6 7 8 9 Name RD(RX) TD (TX) GND DSR RTS CTS Notes: (For EIA-485 4-wire operation) 1. Pins 4 and 8 may be tied together. 2. Pins 5 and 9 may be tied together. Rev. 3 2–13 Installation SMS-301 Redundancy Switch 2.3.6 Prime Power 2.3.6.1 AC Power (J11 and J12) Refer to Table 2-11 for AC prime power requirements. Table 2-11. AC Power (J11 and J12) Description AC power is supplied independently to each of the two power supplies by two standard detachable, non-locking, 3-prong power cords. Maximum Power consumption Input Range Changing Input Voltage 2.3.6.2 Requirements 85 to 264 VAC 30W 85 to 264 VAC No reconfiguration is required. DC Power (J11 and J12) (Optional) Refer to Table 2-12 for DC prime power requirements. Table 2-12. DC Prime Power (J11 and J12) Description Input Range Maximum Power Consumption 2–14 Requirements 42 to 56 VDC 40W Rev. 3 SMS-301 Redundancy Switch 2.3.7 Installation Switch/Modem Communications Interface Connector (J13) The switch/modem communications interface (J13) connector is described in the following listings and pinout data is included in Table 2-13. Interface type: • • • • EIA-485 (2-wire) Baud rate range 9.6 or 19.2 kbit/s ASCII characters 11 bits per character: ! 7 information bits ! 2 stop bits ! 1 parity (Even) ! 1 start bit Table 2-13. Switch/Modem Communications Interface Connector (J13) Pinout Pin # 1 2 3 4 5 6 7 8 9 Rev. 3 Name (2-Wire) GND +TX, +RX -TX, -RX +RX, +TX -RX, -TX 2–15 Installation 2.3.8 SMS-301 Redundancy Switch Status/Fault (J14) Refer to Table 2-14 for Status/Faults (J14) pinout assignments. Connector-Type: 15-Pin D Subminiature, female Form C contact Rating 2A maximum @ 30 VDC, 0.6A @ 125 VAC Table 2-14. Status/Faults (J14) Pinout Assignments Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 2.3.9 Pinout Name Function Spare COM Spare NO Spare NC CEQ COM CEQ NO Common Equipment OK CEQ NC Common Equipment Faulted MODONL COM MODONL NO Mod B On-line Status MODONL NC Mod A On-line Status SW COM SW NO Switch OK SW NC Switch Faulted DMDONL COM DMDONL NO Demod B On-line Status DMDONL NC Demod A On-line Status IF Connections: Transmit and Receive The data is provided in the following listing: Connector type Return loss 2.3.10 BNC 75Ω (50Ω Optional) ≥ 18 dB from 50 to 180 MHz Ground A #10-32 stud is provided on the rear of the chassis for connecting a common chassis ground between all of the equipment. 2–16 Rev. 3 3 Chapter 3. OPERATION This chapter defines the controls and procedures for configuration and operation of the 1:1 switch. Note: Familiarization with the front panel controls (Figure 3-1) and/or the related remote commands described in Appendix A is recommended by Comtech EFData. 3.1 Configuration The configuration of the 1:1 switch may be performed from the front panel, or from a terminal or personal computer connected to the 1:1 switch remote port (J10). Each front panel menu screen, from which entries can be made or status displayed, has a corresponding remote command(s). Unlike the remote commands, the front panel display menus are designed to sequentially guide the operator through the configuration process. Note: Refer to the menu tables presented in this chapter for specific configuration information. Upon completion of the 1:1 switch installation, as described in Chapter 2, the prime modem attached to the 1:1 switch shall be programmed prior to the initial configuration of the switch. Figure 3-1. SMS-301 Front Panel View Rev. 3 3-1 Operation 3.2 SMS-301 Redundancy Switch Setup and Configuration Table 3-1 details the default configuration parameters of the 1:1 switch. The 1:1 switch is returned to this default configuration by performing a hard reset, or upon failure/corruption of non-volatile memory. Table 3-1. Default Configuration Parameters Parameter Operation Mode On-line Modem On-line Mod On-line Demod Switch Mode Modem Delay Mod Delay Demod Delay Modulators Demodulators Time Date Remote Baud Rate Remote Address Remote Type Display Contrast Automatic Verify Modem A Address Modem B Address Modem Baud Rate Condition Automatic A A A Independent 0.0 0.0 0.0 Active Active 12:00:00 AM 7/04/76 9600 bit/s Even 10 EIA-485 (2-wire) Level 64 Disable 1 2 9600 bit/s The following sections detail the minimum modifications necessary to set up a typical 1:1 redundant configuration. In the following setup descriptions, it is assumed Modem A connections are to the prime modem. While proper switch operation does not require Modem A to be the prime modem, it should be noted that upon loss of prime power to the 1:1 switch, Modem A is the default signal pass through path. 3-2 Rev. 3 SMS-301 Redundancy Switch 3.2.1 Operation Utility System Prior to configuration, it may be necessary to modify the following: Display Contrast Remote Options Modem Control Baud Rate 3.2.2 Adjust for optimum viewing in local ambient lighting conditions. If a remote is to be used, appropriate remote options can be verified or defined from the Utilities menu. Select the highest common baud rate for the modems attached to the 1:1 switch. Configuration Upon completion of the installation, the 1:1 switch is ready for configuration to the specific application requirements. Note: The normal operating mode is AUTOMATIC, which shall be changed to MANUAL when locally configuring the 1:1 switch. 3.2.2.1 Prime To configure the 1:1 switch for operation with the prime modem, set the following: Address Mod/Demod Switching Mode Enter a unique 3-digit decimal address for remote communications. ON or OFF; Must be ON for consideration by the switch algorithm. Select INDEPENDENT or DEPENDENT RX/TX switching. Note: INDEPENDENT mode switching can be used to switch the modulator and/or the demodulator. DEPENDENT mode switching always switches the modulator and demodulator. Rev. 3 3-3 Operation 3.2.2.2 SMS-301 Redundancy Switch Backup To configure the 1:1 switch for operation with the backup modem, set the following: Address Mod/Demod Delay Verify Load Enter a 3-digit decimal address for remote communications. ON or OFF; Must be ON for consideration by the switch algorithm. Enter the desired delay. If INDEPENDENT mode switching is selected, enter delay for Mod and Demod. Enable or disable Automatic Verify. This can be used to signal configuration changes between modems. Use the Load Modem A→B option under the Utility Modem Control menu on the 1:1 switch to automatically configure the backup modem to the prime modem configuration. Note: If the backup modem is not to be configured to match the prime modem, the programming of the backup modem shall be performed manually. 3-4 Rev. 3 SMS-301 Redundancy Switch 3.2.2.3 Operation Operation Mode Two modes of operation are available for the 1:1 switch: AUTOMATIC MANUAL If the AUTOMATIC mode is selected, the 1:1 switch algorithm will perform backup operations as defined in the Configuration menus. When the MANUAL mode is selected, the system provides a dedicated menu through which the operator may unconditionally assign backup RX and TX functions to replace the prime modem. Note: The 1:1 switch shall be in AUTOMATIC mode to automatically replace the faulted prime. The manual configuration may be used when Modem A parameters are to be different than Modem B. The 1:1 switch is then used as a master switch. Turn automatic verify off. (The automatic verify is located under the Utility Modem Control menu.) 3.3 Faults Alerts to modem or 1:1 switch faults are provided in several ways: • Indicators on the 1:1 switch control panel, with specific information available in the Faults/Alarms menu. • On demand via the 1:1 switch remote port. Specifics for 1:1 switch and modem faults are available. • Analog status/fault indication signals on the rear of the 1:1 switch (J14). Note: Refer to Chapter 5 for troubleshooting switch faults, or the respective modem manual for modem faults. Rev. 3 3-5 Operation 3.4 SMS-301 Redundancy Switch Front Panel Keypad The front panel keypad permits local operation of the 1:1 switch. The keypad consists of six keys (Figure 3-2). EN TE R C LEAR Figure 3-2. Keypad Each key provides one or more logical functions. The keypad functions are defined in Table 3-2. Table 3-2. Keypad Functions ENTER CLEAR [←] and [→] [↑] and [↓] This key is used to select a displayed function or to execute a 1:1 switch configuration change. This key is used to back out of a selection or to cancel a configuration change which has not been executed using [ENTER]. Pressing [CLEAR] generally returns the display to the previous selection. These keys are used to move to the next selection or to move the cursor for certain functions. These keys are used primarily to change configuration data (numbers) but are also used at times to move from one section to another. The 1:1 switch responds by beeping whenever a key is pressed: 3-6 • A single beep indicates a valid entry and the appropriate action was taken. • A double beep indicates an invalid entry, or a parameter is not available for operation. Rev. 3 SMS-301 Redundancy Switch 3.5 Operation Menu System To access and execute all functions, refer to Figure 3-3 through Figure 3-12. Use the main menu in Figure 3-3 as a quick reference for accessing the 1:1 switch functions. For further configuration details, refer to Section 3.2. When the 1:1 switch power is turned ON, the base level of the menu system displays the sign-on message: • • Line 1 of the sign-on message is the 1:1 switch model number and type. Line 2 is the version number of the firmware. The main level of the menu system is Function Select. To access this level from the sign-on message, press the [←] or [→] keys. From the Function Select menu, select one of the functional categories: • • • • • Configuration Monitor Faults/Alarms Stored Faults/Alarms Utility Press [←] or [→] to move from one selection to another. When line 2 displays the desired function, select that level by pressing [ENTER]. After entering the appropriate functional level, press [←] or [→] to move to the desired function. To view or change the configuration of the 1:1 switch, enter the Configuration level from the Function Select menu. Once in the Configuration menu, press [←] or [→] to scroll through the Configuration menu selection. Press [ENTER] to select the desired Configuration menu option. To view the options for the selected configuration parameters, press [←] or [→]. To change a configuration parameter, press [ENTER] to begin the change process. Rev. 3 3-7 Operation SMS-301 Redundancy Switch Press [↑] or [↓] to change the parameters. After the display represents the correct parameters, press [ENTER] to execute the change. This action initiates the necessary programming by the 1:1 switch. To undo a parameter change prior to execution, press [CLEAR]. The following notes describe each configuration function in detail. Notes: 1. Figure 3-3 through Figure 3-12 list the front panel menu window selections. 2. Menus or commands that are specific to certain 1:1 switch configurations are only accessible after selecting the appropriate 1:1 switch configuration. This prevents incompatible parameters from accidentally being selected. 3-8 Rev. 3 SMS-301 Redundancy Switch 3.5.1 Operation Front Panel Menus SMS-301 VER: 1.1.7 FUNCTION SELECT CONFIGURATION FUNCTION SELECT MONITOR (Figure 3-8) FUNCTION SELECT FAULTS (Figure 3-9) FUNCTION SELECT STORED FAULTS (Figure 3-10) FUNCTION SELECT UTILITY CONFIGURATION SWITCH CONTROL (Figure 3-4) UTLITY SYSTEM (Figure 3-11) CONFIGURATION SYSTEM (Figure 3-5) UTILITY MODEM CONTROL (Figure 3-12) CONFIGURATION SAVE (Figure 3-6) CONFIGURATION RECALL (Figure 3-7) Key: ACCESS TO SUBMENU CONDITIONAL OR OPTIONDEPENDENT Parameter Information Figure 3-3. Main Menu Rev. 3 3-9 Operation SMS-301 Redundancy Switch SMS-301 VER: X.X.X FUNCTION SELECT CONFIGURATION CONFIGURATION SWITCH CONTROL OPERATION MODE ON-LINE MODEM ON-LINE MOD AUTOMATIC MANUAL A-MODEM B-MODEM (Dependent and Manual Mode only) A-MOD B-MOD (Independent and Manual Mode only) ON-LINE DEMOD Key: A-DEMOD B-DEMOD (Independent and Manual Mode only) ACCESS TO SUBMENU CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-4. Configuration Switch Control Menu 3-10 Rev. 3 SMS-301 Redundancy Switch 3.5.1.1 Operation Configuration Switch Control Menu Refer to Figure 3-4. OPERATION MODE Programs the 1:1 switch to AUTOMATIC or MANUAL mode. Upon entry, the current status of the 1:1 switch is displayed. Press [ENTER], then use any of the arrow keys to select. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. ON-LINE MODEM Note: The AUTOMATIC mode is the normal operating mode. The MANUAL mode is required for most configuration changes. Select the prime or backup modem (A-MODEM or B-MODEM). Note: Ensure that the 1:1 switch is in MANUAL mode. Upon entry, the current status of the 1:1 switch is displayed. Press [ENTER], then use any of the arrow keys to select. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. ON-LINE MOD Note: This feature is available in the DEPENDENT and MANUAL mode only. Select the prime or backup MODULATOR. Note: Ensure that the 1:1 switch is in MANUAL mode. Upon entry, the current status of the 1:1 switch is displayed. Press [ENTER], then use any of the arrow keys to select. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. ON-LINE DEMOD Note: This feature is available in the INDEPENDENT and MANUAL mode only. In the ON-LINE DEMODULATOR, the operator can select a prime or backup demodulator. Note: Ensure 1:1 switch is in MANUAL mode. Upon entry, the current status of the 1:1 switch is displayed. Press [ENTER], then use any of the arrow keys to select. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. Note: This feature is available in the INDEPENDENT and MANUAL mode only. Rev. 3 3-11 Operation SMS-301 Redundancy Switch SMS-301 VER: X.X.X FUNCTION SELECT CONFIGURATION CONFIGURATION SYSTEM SWITCH MODE MODEM DELAY MODULATOR DELAY INDEPENDENT DEPENDENT (Change in Manual mode only) 0.0 to 127.0 seconds, in 0.5 second increments. (Change in Dependent mode only) 0.0 to 127.0 seconds, in 0.5 second increments. (Change in Independent mode only) DEMODULATOR DELAY 0.0 to 127.0 seconds, in 0.5 second increments. (Change in Independent mode only) MODULATORS ACTIVE IN-ACTIVE (Change in Manual mode only) DEMODULATORS ACTIVE IN-ACTIVE (Change in Manual mode only) Key: ACCESS TO SUBMENU CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-5. Configuration System Menu 3-12 Rev. 3 SMS-301 Redundancy Switch 3.5.1.2 Operation Configuration System Menu Refer to Figure 3-5 for the Configuration System. SWITCH MODE Programs the 1:1 switch to INDEPENDENT or DEPENDENT mode. DEPENDENT— If a prime component (modulator or demodulator) faults, the prime system will go off-line. The backup system (modulator and demodulator) will come on-line. INDEPENDENT— If a prime component (modulator or demodulator) faults, the backup component (modulator or demodulator) will come on-line. Note: Ensure 1:1 switch is in MANUAL mode. MODEM DELAY Upon entry, the current status of the 1:1 switch is displayed. Press [ENTER], then use any of the arrow keys to select. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. Programs a switching delay of 0 to 127 seconds, in 0.5 second increments. Note: Ensure 1:1 switch is in DEPENDENT mode MODULATOR DELAY Upon entry, the current status of the 1:1 switch is displayed. Press [←] or [→] to move the flashing cursor. Press [↑] or [↓] to increase or decrease the numbers. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. Programs a switching delay of 0 to 127 seconds, in 0.5 second increments. Note: Ensure 1:1 switch is in INDEPENDENT mode DEMODULATOR DELAY Upon entry, the current status of the 1:1 switch is displayed. Press [←] or [→] to move the flashing cursor. Press [↑] or [↓] to increase or decrease the numbers. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. Programs a switching delay of 0 to 127 seconds, in 0.5 second increments. Note: Ensure 1:1 switch is in INDEPENDENT mode MODULATORS Upon entry, the current status of the 1:1 switch is displayed. Press [←] or [→] to move the flashing cursor. Press [↑] or [↓] to increase or decrease the numbers. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. Programs the modulators to ACTIVE or INACTIVE. Note: Ensure 1:1 switch is in MANUAL mode. DEMODULATORS Rev. 3 Upon entry, the current status of the 1:1 switch is displayed. Press [ENTER], then use any of the arrow keys to select. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. Programs the demodulators to ACTIVE or INACTIVE. 3-13 Operation SMS-301 Redundancy Switch Note: Ensure 1:1 switch is in MANUAL mode. Upon entry, the current status of the 1:1 switch is displayed. Press [ENTER], then use any of the arrow keys to select. Press [ENTER] to execute the change, or [CLEAR] to abandon the change. 3-14 Rev. 3 SMS-301 Redundancy Switch Operation SMS-301 VER: X.X.X FUNCTION SELECT CONFIGURATION CONFIGURATION SAVE CONFIGURATION #X SAVE Key: ACCESS TO SUBMENU X = 1, 2, 3, 4, or 5. CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-6. Configuration Save Menu 3.5.1.3 Configuration Save Menu Refer to Figure 3-6. CONFIGURATION #X SAVE X = 1, 2, 3, 4, or 5. Provides five memory locations for configurations to be saved into on the M&C. Press [ENTER], then use any of the arrow keys to select the desired memory location. Press [ENTER] to execute the save, or [CLEAR] to abandon the save. Rev. 3 3-15 Operation SMS-301 Redundancy Switch SMS-301 VER: X.X.X FUNCTION SELECT CONFIGURATION CONFIGURATION RECALL CONFIGURATION #X RECALL Key: ACCESS TO SUBMENU X = 1, 2, 3, 4, or 5. CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-7. Configuration Recall Menu 3.5.1.4 Configuration Recall Menu Refer to Figure 3-7. CONFIGURATION #X RECALL X = 1, 2, 3, 4, or 5. Allows the recall of configurations that were previously saved on the M&C. Press [ENTER], then use any of the arrow keys to select the desired memory location. Press [ENTER] to execute the recall, or [CLEAR] to abandon the recall. 3-16 Rev. 3 SMS-301 Redundancy Switch SMS-301 VER: X.X.X Operation FUNCTION SELECT MONITOR MOD MM X-ONLINE DMD DD Y-ONLINE Key: MM = A and B, Modulators Active. DD = A and B, Demodulators Active. X = A or B, Modulator Online. Y = A or B, Demodulator Online. Status only. ACCESS TO SUBMENU CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-8. Monitor Menu 3.5.1.5 Monitor Menu Refer to Figure 3-8. MOD MM X–ONLINE DMD DD Y–ONLINE (Status Only.) Line 1 displays summary of active prime modems and online backup modems. Line 2 displays summary of active prime and online backup demodulators. Where: MM = A and B, indicates modulators are active. If not active, an “_” is displayed. DD = A and B, indicates demodulators are active. If not active, an “_” is displayed. X = A or B, indicates modulator A or B online. Y = A or B, indicates demodulators A or B online. Rev. 3 3-17 Operation SMS-301 Redundancy Switch SMS-301 VER: X.X.X FUNCTION SELECT FAULTS/ALARMS OPERATIONAL ++ MOD ONLINE DMD ONLINE COMMON ------+--- BATTERY/CLOCK +12 VOLT SUPPLY +5 VOLT SUPPLY PWR SUPPLY #1 PWR SUPPLY #2 CONTROLLER MODEM COM LINK MOD VERIFY DEMOD VERIFY INTERFACE MODULE Key: ACCESS TO SUBMENU CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-9. Faults/Alarms Menu 3-18 Rev. 3 SMS-301 Redundancy Switch 3.5.1.6 Operation Faults/Alarms Refer to Figure 3-9. The Faults/Alarms level is accessible from the Function Select menu. Press [←] or [→] to move between the following Faults/Alarms groups: OPERATIONAL X (Status Only) X = 0 through 9. Displays the fault status of the currently selected on-line modulator and demodulator. COMMON When a fault is present, the date and time of the fault is displayed alternately. (Status Only) Note: Date and time faults are also displayed. Use [←] or [→] to display faults within the 1:1 switch, such as the following: Battery Clock - Battery or clock fault. • +12V Supply - +12V supply fault. • +5V Supply - +5V supply fault • Power Supply #1 - Power supply #1 fault. • Power Supply #2 - Power supply #2 fault. • Controller - Controller power ON/OFF cycle fault. • Modem COMM Link - Modem communications fault. • Modem Verify- Prime and backup modems do not match. • DEMOD Verify - Prime and backup DEMODS do not match. • Interface Module - Interface module is missing or will not program • fault. Rev. 3 3-19 Operation SMS-301 Redundancy Switch SMS-301 VER: X.X.X OPERATIONAL ++ MOD ONLINE DMD ONLINE FUNCTION SELECT STORED FLTS/ALMS COMMON ------+--- BATTERY/CLOCK +12 VOLT SUPPLY +5 VOLT SUPPLY PWR SUPPLY #1 PWR SUPPLY #2 CONTROLLER MODEM COM LINK MOD VERIFY DEMOD VERIFY INTERFACE MODULE CLEAR ?? STORED FAULTS Press [ENTER] twice to clear stored faults. Key: ACCESS TO SUBMENU CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-10. Stored Faults/Alarms Menu 3-20 Rev. 3 SMS-301 Redundancy Switch 3.5.1.7 Operation Stored Faults/Alarms Refer to Figure 3-10. OPERATIONAL X (Status Only) X = 0 through 9. Displays the fault status of the currently selected on-line modulator and demodulator. COMMON When a stored fault is present, the date and time of the fault will be displayed alternately. (Status Only) Note: Date and time of faults also are displayed. CLEAR?? STORED FAULTS Press [←] or [→] to display faults within the 1:1 switch, such as the following: • Battery Clock - Battery or clock fault. • +12V Supply - +12V supply fault. • +5V Supply - +5V supply fault • Power Supply #1 - Power supply #1 fault. • Power Supply #2 - Power supply #2 fault. • Controller - Controller power ON/OFF cycle fault. • Modem COMM Link - Modem communications fault. • Modem Verify- Prime and backup modems do not match. • DEMOD Verify - Prime and backup DEMODS do not match. • Interface Module - Interface module is missing or will not program fault. Allows the operator to clear all stored faults within the memory of the 1:1 switch. Press [ENTER], then ‘YES’ is displayed. Press [ENTER] to confirm clearing all stored faults, or press [CLEAR] to exit without clearing stored faults. Rev. 3 3-21 Operation SMS-301 Redundancy Switch SMS-301 VER: X.X.X TIME: 12:00:00AM DATE: 12/12/97 Current time: HH:MM:SS AM Current date: MM/DD/YY LAMP TEST ?? PRESS ENTER Illuminates all front panel LEDs for three seconds M&C FIRMWARE FW/NNNNNN-DDR NNNNNN = Number DD = Dash Number R = Revision Number Press [ENTER] to view date of M&C firmware. FUNCTION SELECT UTILITY UTILITY SYSTEM REMOTE BAUD RATE REMOTE ADDRESS REMOTE TYPE 1 to 255 RS232 RS485 (2-WIRE) RS485 (4-WIRE) Baud rate:150, 300, 600, 1200, 2400, 4800, 9600, 19200 Parity: EVEN, ODD, or NONE. DISPLAY CONTRAST LEVEL: 64 Sets the display contrast level as desired, from 0 to 100. BOOT FIRMWARE FW/NNNNNN-DDR INTERFACE TYPE Status only. POWER SUPPLY 1 ACTIVE 2 ACTIVE 1&2 ACTIVE MASTER RESET HARD/SOFT NNNNNN = Number DD = Dash Number R = Revision Number Press [ENTER] to view date and version number of Boot firmware. SOFT HARD Key: ACCESS TO SUBMENU CONDITIONAL OR OPTION-DEPENDENT Parameter Information Figure 3-11. Utility System Menu 3-22 Rev. 3 SMS-301 Redundancy Switch 3.5.1.8 Operation Utility System Refer to Figure 3-11. TIME: HH:MM:SS AM DATE: MM/DD/YY Time of day and date display/set function. To change the time and/or date: Note: Ensure 1:1 switch is in MANUAL mode. REMOTE BAUD RATE Press [←] or [→] to position the cursor over the parameter to be changed. Press [↑] or [↓] to change the parameter. Once the parameters are set as desired, press [ENTER] to set the time and date. The parity and baud rate settings of the 1:1 switch are displayed. To change the baud rate and/or parity, perform the following: Note: Ensure 1:1 switch is in MANUAL mode. The available baud rates are as follows: 150, 300, 600, 1200, 2400, 4800, 9600, or 19200 bps. Baud rates are set by pressing [ENTER], and then [↑] or [↓] to select the desired rate. Press [ENTER] to accept the change, or [CLEAR] to abandon the change. REMOTE ADDRESS The parity can be set to EVEN, ODD, or NONE, by pressing [ENTER], [→] to place the cursor on the parity setting, and then [↑] or [↓] to select the desired setting. Press [ENTER] to accept the change, or [CLEAR] to abandon the change. The current 1:1 switch address is displayed (1 to 255). To change the remote address, press [ENTER], then [←] or [→] to position the cursor over the parameter to be changed. Press [↑] or [↓] to change the parameter, then press [ENTER] to accept the change, or [CLEAR] to abandon the change. REMOTE TYPE LAMP TEST ?? PRESS ENTER Rev. 3 Note: A 0 address is reserved for global use only. Displays the current remote type: EIA-232, EIA-485 (2-Wire), or EIA-485 (4-Wire). To change the remote type, press [ENTER], then any of the arrow keys to select the desired remote type. Press [ENTER] to accept the change, or [CLEAR] to abandon the change. Lamp test function. Press [ENTER] to turn all front panel LED indicators ON for 3 seconds. 3-23 Operation SMS-301 Redundancy Switch DISPLAY CONTRAST Sets the display contrast setting, as desired. Note: Ensure 1:1 switch is in MANUAL mode. INTERFACE TYPE To change the display contrast, press [ENTER], then [←] or [→] to position the cursor over the parameter to be changed. Press [↑] or [↓] to change the parameter, then press [ENTER] to accept the change, or [CLEAR] to abandon the change. (Status Only) Displays the currently installed interface type, as follows: POWER SUPPLY M&C FIRMWARE BOOT FIRMWARE MASTER RESET HARD/SOFT 50-Pin 25-Pin (V.35) 37-Pin 37-Pin (LVDS) 25-Pin (EIA-232) 37-Pin (EIA-422) 25-Pin (EIA-530) Displays the currently selected power supply (1 ACTIVE, 2 ACTIVE, or 1&2 ACTIVE). To change the power supply setting, press [ENTER], then any of the arrow keys to select the desired setting. Press [ENTER] to accept the change, or [CLEAR] to abandon the change. Displays the M&C firmware version number. Press [ENTER] to display the date of the M&C firmware. Displays the BOOT firmware version number. Press [ENTER] to display the date of the BOOT firmware. Master reset function (SOFT or HARD). CAUTIO N Initiating a HARD reset will reset the 1:1 switch and place the default configuration settings in ROM. Initiating a SOFT reset will reset the 1:1 switch hardware, but saves the current configuration settings. To perform a master reset, press [ENTER], any of the arrow keys to select the type, then press [ENTER] again. Press [→] five times to position the cursor on YES. Press [ENTER] to confirm the reset type and execute the reset, or [CLEAR] to change reset type and/or abandon the reset. Note: The following parameters do not revert to default settings after a hard reset: Address Parity Baud Rate Remote Type Display Contrast 3-24 Rev. 3 SMS-301 Redundancy Switch Operation This page is intentionally left blank. Rev. 3 3-25 Operation SMS-301 Redundancy Switch S M S -301 V ER : X.X.X FU N C T IO N S E LE C T U T ILIT Y U T ILIT Y MO DEM CONTROL A U T O M A T IC VE R IFY LO A D M O D EM A ->B LO A D M O D EM B ->A M O D E M A A D D R E SS E N A BLE D ISA B LE P ress [EN T E R ] twice to copy M odem A configuration to M odem B. P ress [EN T E R ] twice to copy M odem B configuration to M odem A . 1 to 255. M O D E M B A D D R E SS MO DEM BAUD RATE R E V E M U LAT IO N C U R R EN T _V E R S IO N 1 to 255. 9600 19200 S tatus only. Key: A C C ES S TO S U B M EN U C O N D ITION AL OR O P TION -D E PE N D E N T P a ra m e ter In fo rm atio n Figure 3-12. Utility Modem Control Menu 3-26 Rev. 3 SMS-301 Redundancy Switch 3.5.1.9 Operation Utility Modem Control Refer to Figure 3-12. AUTOMATIC VERIFY Selects ENABLE or DISABLE for automatic verify feature. LOAD MODEM A → B To change the setting, press [ENTER], then use any of the arrow keys to select. Press [ENTER] to accept the change, or [CLEAR] to abandon the change. Copies Modem A configuration to Modem B. LOAD MODEM B → A To perform the copy function, press [ENTER] twice. Copies Modem B configuration to Modem A. MODEM A ADDRESS To perform the copy function, press [ENTER] twice. Selects an address from 1 to 255 for Modem A. To change the address for Modem A, press [ENTER], then [←] or [→] to position the cursor over the parameter to be changed. Press [↑] or [↓] to change the parameter, then press [ENTER] to accept the change, or [CLEAR] to abandon the change. MODEM B ADDRESS Note: A 0 address is reserved for global use only. Selects an address for Modem B. To change the address for Modem B, press [ENTER], then [←] or [→] to position the cursor over the parameter to be changed. Press [↑] or [↓] to change the parameter, then press [ENTER] to accept the change, or [CLEAR] to abandon the change. MODEM BAUD RATE Note: A 0 address is reserved for global use only. Selects the modem baud rate (9600 or 19200 bit/s). To change the modem baud rate, press [ENTER], then any of the arrow keys to select. Press [ENTER] to accept the change, or [CLEAR] to abandon the change. Rev. 3 3-27 Operation SMS-301 Redundancy Switch REV EMULATION Programs an emulation mode of the previous functional revision. This allows the operator to select the CURRENT VERSION or FUNCTIONAL X: Note: The number displayed in the CURRENT VERSION position increases with each software version change. Upon entry, the CURRENT VERSION is displayed. Press [↑] or [↓] to select the FUNCTIONAL version. Press [ENTER] to execute the change. Notes: 1. Programming a current version (default) allows all features and options (if installed) to operate normally. 2. Programming a FUNCTIONAL version (X) eliminates any changes that affect the later version. Only functional changes are affected by the revision emulation feature. 3. A correction change (e.g., VER 1.1.1) remains fixed in accordance with the latest version. Since the revision emulation default is the current version, program the functional version at the start of each operation. 4. The revision emulation feature does not affect some interface changes for the direct operation of the modem (Configuration Save/Recall, test mode screen in the Utility/System, all factory setup modes, etc.). 3-28 Rev. 3 4 Chapter 4. THEORY OF OPERATION This chapter provides the basic theory of operation for the following: • • • • • • • • 4.1 M&C 75Ω M&C 50Ω IBS, IDR, ASYNC, D&I, 50-pin (PL/5951) EIA-422/-449, V.35, G.703, 37-pin (PL/5952) LVDS/DVB-TX, 37-pin (PL/6201-1) EIA-422/DVB-TX, 37-pin (PL/6201-2) EIA-232/-422/-530, V.35, G.703 25-pin (PL/6026) Remote Switch Option (RS-301), 100-pin (PL6592/6627) Monitor and Control (M&C) The M&C monitors the switch configuration, as well as 1:1 switch and modem faults and status. 1:1 switch configuration parameters are stored in battery-backed RAM to provide total recovery after a power-down. The 1:1 switch gathers status and provides extensive fault monitoring. A local front panel interface and a remote communications interface provide user access to all 1:1 switch functions. Rev. 3 4-1 Theory of Operation 4.1.1 SMS-301 Redundancy Switch Theory of Operation The M&C module uses an Intel 80C32 microcontroller operating at 11.0592 MHz. The microsystem supports 256 kbit/s of FLASH memory for code and data. Memory-mapped I/O includes: • • • Real time clock/memory 8-channel analog-to-digital converter External buffered bus structure for overall 1:1 switch control and status gathering. The 80C32 microcontroller supports a serial, asynchronous, remote control (J10) communications channel (EIA-232 or EIA-485) with a maximum baud rate of 19200 bit/s. The modem control interface (J13) is an EIA-485 serial communication link which allows the 1:1 switch to monitor and configure the attached modems. A lithium battery maintains the system real time clock and 1:1 switch configuration through power-down situations. The M&C motherboard interfaces and controls a variety of data interface connector switch boards. The customer-application dictates the type of connector switch board to be installed within the 1:1 switch. 4-2 Rev. 3 SMS-301 Redundancy Switch Theory of Operation 4.2 SMS-301 Data Interface 4.2.1 IBS, IDR, ASYNC, or D&I (J1, J2, J3), 50-Pin (PL/5951) The applications for this board are IDR, IBS, ASYNC, or D&I format data. The board consists of three 50-pin data I/O connectors, interface, and switching electronics. There are no configuration jumpers on the 50-pin board. The interface to the M&C motherboard is via a 40-pin connector located along one side of the board. The board, under M&C control, will switch data between the prime modem (J2), and/or the backup modem (J3), and the common customer-data interface (J1). The M&C automatically detects the type of board installed and presents this information, via the front panel display, under Interface Type in the Utility System menu. 4.2.2 EIA-422/-449, G.703, or V.35 (J1, J2, J3), 37-Pin (PL/5952) The applications for this board are EIA-422/-449, G.703 or V.35 format data. The board consists of three 37-pin data I/O connectors, interface, and switching electronics. The interface to the M&C motherboard is via a 40-pin connector located along one side of the board. The board, under M&C control, will switch data between the prime modem (J2), and/or the backup modem (J3), and the common customer-data interface (J1). The M&C automatically detects the type of switch board installed and presents this information, via the front panel display, under Interface Type in the Utility System menu. 4.2.3 LVDS-DVB TX, (J1, J2, J3), 37-Pin, (PL/6201-1) There are no configuration jumpers on the LVDS board. The current version of this board is for the SDM-2020 Satellite Modulator only. The intended signal flow path is from the customer-connection on J1 to the switched equipment on J2 and J3. In the powered down state, this board provides an unbuffered signal path from J1 to J2. When power is available to the board, the signals from J1 to J2 and J3 are buffered. Rev. 3 4-3 Theory of Operation 4.2.4 SMS-301 Redundancy Switch EIA-422/DVB TX (J1, J2, J3), 25-Pin (PL/6026) The applications for this switch board are EIA-232, EIA-422, or V.35 format data. The switch board consists of three 25-pin data I/O connectors, interface, and switching electronics. The interface to the M&C motherboard is via a 40-pin connector located along one side of the switch board. The switch board, under M&C control, will switch data between the prime modem (J2), and/or the backup modem (J3), and the common customer-data interface (J1). The M&C automatically detects the type of switch board installed and presents this information, via the front panel display, under Interface Type in the Utility System menu. 4-4 Rev. 3 SMS-301 Redundancy Switch 4.3 Theory of Operation Remote Switch (RS-301) Option The application for this option is to provide access to tributary data, via the remote switch, when the 1:1 switch is used with two SDM-300/-300A Satellite Modems that are configured for the 8-Channel MUX option. For this option an extender board (AS/6542) replaces the switch board that normally resides within the 1:1 switch. This extender board interfaces with the M&C motherboard and provides control signals, power and ground to an external data switch (RS-301). The remote switch (RS-301) provides the user with connections for eight tributary channels (EIA-422, EIA-232 data and clock) and one connection for auxiliary data. This switch, under M&C control, will switch data (only) between the prime modem and/or the backup modem, and the customer-data interface. The TX IF switching remains internal to the 1:1 switch. The M&C automatically detects this switch option and presents this information, via the front panel display, under Interface Type in the Utility System menu. The connectors for the remote switch are listed in Table 4-1. Table 4-1. Remote Switch (RS-301) Connectors Name TRIBUTARY 1 DATA REF DES J1 TRIBUTARY 2 DATA J2 15-pin D TRIBUTARY 3 DATA J3 15-pin D TRIBUTARY 4 DATA J4 15-pin D TRIBUTARY 5 DATA J5 15-pin D TRIBUTARY 6 DATA J6 15-pin D TRIBUTARY 7 DATA J7 15-pin D TRIBUTARY 8 DATA J8 15-pin D AUX MODEM A DATA MODEM B DATA SWITCH CONTROL INTERFACE J9 J14 J15 J16 15-pin D 100-pin Miniature D 100-pin Miniature D 37-pin D Rev. 3 Connector Type 15-pin D Function EIA-422 or EIA-232 TRIB 1 Clock and Data EIA-422 or EIA-232 TRIB 2 Clock and Data EIA-422 or EIA-232 TRIB 3 Clock and Data EIA-422 or EIA-232 TRIB 4 Clock and Data EIA-422 or EIA-232 TRIB 5 Clock and Data EIA-422 or EIA-232 TRIB 6 Clock and Data EIA-422 or EIA-232 TRIB 7 Clock and Data EIA-422 or EIA-232 TRIB 8 Clock and Data Auxiliary Data Modem A Data I/O Modem B Data I/O Control Signals, Power and Ground Table Reference Table 4-2 Table 4-3 Table 4-4 Table 4-5 Table 4-6 Table 4-7 Table 4-8 Table 4-9 Table 4-10 Table 4-11 Table 4-12 Table 4-13 4-5 Theory of Operation SMS-301 Redundancy Switch Table 4-2. Tributary 1 Data (J1) Pin No. 1 2, 5, 11 3 4 6 9 10 12 13 14 Name CTS422A1 GND TC422B-1 TD422A-1 TD232-1 CTS422B1 TC422A-1 TD422B-1 CTS232-1 TC232-1 Function EIA-422, Clear-to-Send A (-) Ground EIA-422, TX Clock B (+) EIA-422 TX Data A (-) EIA-232 TX Data EIA-422 Clear-to-Send B (+) EIA-422 TX Clock A (-) EIA-422 TX Clock B (+) EIA-232 Clear-to-Send EIA-232 TX Clock Table 4-3. Tributary 2 Data (J2) Pin No. 1 2, 5, 11 3 4 6 9 10 12 13 14 Name CTS422A2 GND TC422B-2 TD422A-2 TD232-2 CTS422B2 TC422A-2 TD422B-2 CTS232-2 TC232-2 Function EIA-422, Clear-to-Send A (-) Ground EIA-422, TX Clock B (+) EIA-422 TX Data A (-) EIA-232 TX Data EIA-422 Clear-to-Send B (+) EIA-422 TX Clock A (-) EIA-422 TX Clock B (+) EIA-232 Clear-to-Send EIA-232 TX Clock Table 4-4. Tributary 3 Data (J3) Pin No. 1 2, 5, 11 3 4 6 9 10 12 13 14 4-6 Name CTS422A3 GND TC422B-3 TD422A-3 TD232-3 CTS422B3 TC422A-3 TD422B-3 CTS232-3 TC232-3 Function EIA-422, Clear-to-Send A (-) Ground EIA-422, TX Clock B (+) EIA-422 TX Data A (-) EIA-232 TX Data EIA-422 Clear-to-Send B (+) EIA-422 TX Clock A (-) EIA-422 TX Clock B (+) EIA-232 Clear-to-Send EIA-232 TX Clock Rev. 3 SMS-301 Redundancy Switch Theory of Operation Table 4-5. Tributary 4 Data (J4) Pin No. 1 2, 5, 11 3 4 6 9 10 12 13 14 Name CTS422A4 GND TC422B-4 TD422A-4 TD232-4 CTS422B4 TC422A-4 TD422B-4 CTS232-4 TC232-4 Function EIA-422, Clear-to-Send A (-) Ground EIA-422, TX Clock B (+) EIA-422 TX Data A (-) EIA-232 TX Data EIA-422 Clear-to-Send B (+) EIA-422 TX Clock A (-) EIA-422 TX Clock B (+) EIA-232 Clear-to-Send EIA-232 TX Clock Table 4-6. Tributary 5 Data (J5) Pin No. 1 2, 5, 11 3 4 6 9 10 12 13 14 Name CTS422A5 GND TC422B-5 TD422A-5 TD232-5 CTS422B5 TC422A-5 TD422B-5 CTS232-5 TC232-5 Function EIA-422, Clear-to-Send A (-) Ground EIA-422, TX Clock B (+) EIA-422 TX Data A (-) EIA-232 TX Data EIA-422 Clear-to-Send B (+) EIA-422 TX Clock A (-) EIA-422 TX Clock B (+) EIA-232 Clear-to-Send EIA-232 TX Clock Table 4-7. Tributary 6 Data (J6) Pin No. 1 2, 5, 11 3 4 6 9 10 12 13 14 Rev. 3 Name CTS422A6 GND TC422B-6 TD422A-6 TD232-6 CTS422B6 TC422A-6 TD422B-6 CTS232-6 TC232-6 Function EIA-422, Clear-to-Send A (-) Ground EIA-422, TX Clock B (+) EIA-422 TX Data A (-) EIA-232 TX Data EIA-422 Clear-to-Send B (+) EIA-422 TX Clock A (-) EIA-422 TX Clock B (+) EIA-232 Clear-to-Send EIA-232 TX Clock 4-7 Theory of Operation SMS-301 Redundancy Switch Table 4-8. Tributary 7 Data (J7) Pin No. 1 2,5,11 3 4 6 9 10 12 13 14 Name CTS422A7 GND TC422B-7 TD422A-7 TD232-7 CTS422B7 TC422A-7 TD422B-7 CTS232-7 TC232-7 Function EIA-422, Clear-to-Send A (-) Ground EIA-422, TX Clock B (+) EIA-422 TX Data A (-) EIA-232 TX Data EIA-422 Clear-to-Send B (+) EIA-422 TX Clock A (-) EIA-422 TX Clock B (+) EIA-232 Clear-to-Send EIA-232 TX Clock Table 4-9. Tributary 8 Data (J8) Pin No. 1 2,5,11 3 4 6 9 10 12 13 14 Name CTS422A8 GND TC422B-8 TD422A-8 TD232-8 CTS422B8 TC422A-8 TD422B-8 CTS232-8 TC232-8 Function EIA-422, Clear-to-Send A (-) Ground EIA-422, TX Clock B (+) EIA-422 TX Data A (-) EIA-232 TX Data EIA-422 Clear-to-Send B (+) EIA-422 TX Clock A (-) EIA-422 TX Clock B (+) EIA-232 Clear-to-Send EIA-232 TX Clock Table 4-10. AUX Data (J9) Pin No. 1 2,5,11 3 4 6 7 8 9 10 12 13 14 15 4-8 Name MCA GND RT-B RD-A RR-B N/C MF MCB RT-A RD-B RR-A N/C DF Function TX Aggregate Clock Ground EIA-422, RX Timing B (+) EIA-422, RX Data A (-) RX Ready B (+) No Connection MOD Fault TX Aggregate Data EIA-422, RX Timing A (-) EIA-422, RX Data B (+) RX Ready A (-) No Connection DEMOD Fault Rev. 3 SMS-301 Redundancy Switch Theory of Operation Table 4-11. Modem A Data (J14) Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Circuit GND GND /A_DF /A_MF GND A_RT+B A_RT-A GND A_RD+B A_RD-A GND A_RR+B A_RR-A GND A_MCB A_MCA GND A_TC232_8 A_TD232_8 A_CTS232_8 A_TD422B_8 A_TD422A_8 A_TC422B_8 A_TC422A_8 A_CTS422B8 A_CTS422A8 GND A_TC232_7 A_TD232_7 A_CTS232_7 A_TD422B_7 A_TD422A_7 A_TC422B_7 A_TC422A_7 A_CTS422B7 A_CTS422A7 GND A_TC232_6 A_TD232_6 A_CTS232_6 A_TD422B_6 A_TD422A_6 A_TC422B_6 A_TC422A_6 A_CTS422B6 A_CTS422A6 Rev. 3 Description N/A N/A N/A N/A GROUND GROUND DEMOD FAULT MOD FAULT GROUND RECEIVE TIMING B (+) RECEIVE TIMING A (-) GROUND RECEIVE DATA B (+) RECEIVE DATA A (-) GROUND RECEIVER READY B (+) RECEIVER READY A (-) GROUND MASTER CLOCK B MASTER CLOCK A GROUND EIA-232, TX CLK, TRIB 8 EIA-232, TX DAT, TRIB 8 EIA-232, CTS, TRIB 8 EIA-422, TX DATB (+), TRIB 8 EIA-422, TX DATA (-), TRIB 8 EIA-422, TX CLKB (+), TRIB 8 EIA-422, TX CLKA (-), TRIB 8 EIA-422, CTSB (+), TRIB 8 EIA-422, CTSA (-), TRIB 8 GROUND EIA-232 ,TX CLK, TRIB 7 EIA-232, TX DAT, TRI 7 EIA-232, CTS, TRIB 7 EIA-422, TX DATB (+), TRIB 7 EIA-422, TX DATA (-), TRIB 7 EIA-422, TX CLKB (+), TRIB 7 EIA-422, TX CLKA (-), TRIB 7 EIA-422, CTSB (+), TRIB 7 EIA-422, CTSA (-), TRIB 7 GROUND EIA-232, TX CLK, TRIB 6 EIA-232, TX DAT, TRIB 6 EIA-232, CTS, TRIB 6 EIA-422, TX DATB (+),TRIB 6 EIA-422, TX DATA (-), TRIB 6 EIA-422, TX CLKB (+), TRIB 6 EIA-422, TX CLKA (-), TRIB 6 EIA-422, CTSB (+), TRIB 6 EIA-422, CTSA (-), TRIB 6 Pin # 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Circuit GND A_TC232_5 A_TD232_5 A_CTS232_5 A_TD422B_5 A_TD422A_5 A_TC422B_5 A_TC422A_5 A_CTS422B5 A_CTS422A5 GND A_TC232_4 A_TD232_4 A_CTS232_4 A_TD422B_4 A_TD422A_4 A_TC422B_4 A_TC422A_4 A_CTS422B4 A_CTS422A4 GND A_TC232_3 A_TD232_3 A_CTS232_3 A_TD422B_3 A_TD422A_3 A_TC422B_3 A_TC422A_3 A_CTS422B3 A_CTS422A3 GND A_TC232_2 A_TD232_2 A_CTS232_2 A_TD422B_2 A_TD422A_2 A_TC422B_2 A_TC422A_2 A_CTS422B2 A_CTS422A2 GND A_TC232_1 A_TD232_1 A_CTS232_1 A_TD422B_1 A_TD422A_1 A_TC422B_1 A_TC422A_1 A_CTS422B1 A_CTS422A1 Description GROUND EIA-232, TX CLK, TRIB 5 EIA-232, TX DAT, TRIB 5 EIA-232, CTS, TRIB 5 EIA-422, TX DATB (+), TRIB 5 EIA-422, TX DATA (-), TRIB 5 EIA-422, TX CLKB (+), TRIB 5 EIA-422, TX CLKA (-), TRIB 5 EIA-422, CTSB (+), TRIB 5 EIA-422, CTSA (-), TRIB 5 GROUND EIA-232, TX CLK, TRIB 4 EIA-232, TX DAT, TRIB 4 EIA-232, CTS, TRIB 4 EIA-422, TX DATB (+), TRIB 4 EIA-422, TX DATA (-), TRIB 4 EIA-422, TX CLKB (+), TRIB 4 EIA-422, TX CLKA (-), TRIB 4 EIA-422, CTSB (+), TRIB 4 EIA-422, CTSA (-), TRIB 4 GROUND EIA-232 ,TX CLK, TRIB 3 EIA-232, TX DAT, TRIB 3 EIA-232, CTS, TRIB EIA-422, TX DATB (+), TRIB 3 EIA-422, TX DATA (-), TRIB 3 EIA-422, TX CLKB (+), TRIB 3 EIA-422, TX CLKA (-), TRIB 3 EIA-422, CTSB (+), TRIB 3 EIA-422, CTSA (-), TRIB 3 GROUND EIA-232, TX CLK, TRIB 2 EIA-232, TX DAT, TRIB 2 EIA-232, CTS, TRIB 2 EIA-422, TX DATB (+), TRIB 2 EIA-422, TX DATA (-), TRIB 2 EIA-422, TX CLKB (+), TRIB 2 EIA-422, TX CLKA (-), TRIB 2 EIA-422, CTSB (+), TRIB 2 EIA-422, CTSA (-), TRIB 2 GROUND EIA-232, TX CLK, TRIB 1 EIA-232, TX DAT, TRIB 1 EIA-232, CTS, TRIB 1 EIA-422, TX DATB (+), TRIB 1 EIA-422, TX DATA (-), TRIB 1 EIA-422, TX CLKB (+), TRIB 1 EIA-422, TX CLKA (-), TRIB 1 EIA-422 CTSB (+), TRIB 1 EIA-422, CTSA (-), TRIB 1 4-9 Theory of Operation SMS-301 Redundancy Switch Table 4-12. Modem B Data (J15) Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 4-10 Circuit GND GND /B_DF /B_MF GND B_RT+B B_RT-A GND B_RD+B B_RD-A GND B_RR+B B_RR-A GND B_MCB B_MCA GND B_TC232_8 B_TD232_8 B_CTS232_8 B_TD422B_8 B_TD422A_8 B_TC422B_8 B_TC422A_8 B_CTS422B8 B_CTS422A8 GND B_TC232_7 B_TD232_7 B_CTS232_7 B_TD422B_7 B_TD422A_7 B_TC422B_7 B_TC422A_7 B_CTS422B7 B_CTS422A7 GND B_TC232_6 B_TD232_6 B_CTS232_6 B_TD422B_6 B_TD422A_6 B_TC422B_6 B_TC422A_6 B_CTS422B6 B_CTS422A6 Description N/A N/A N/A N/A GROUND GROUND DEMOD FAULT MOD FAULT GROUND RECEIVE TIMING B(+) RECEIVE TIMING A(-) GROUND RECEIVE DATA B(+) RECEIVE DATA A(-) GROUND RECEIVER READY B(+) RECEIVER READY A(-) GROUND MASTER CLOCK B MASTER CLOCK A GROUND EIA-232,TX CLK, TRIB 8 EIA-232,TX DAT, TRI 8 EIA-232, CTS, TRIB 8 EIA-422, TX DATB (+), TRIB 8 EIA-422, TX DATA (-), TRIB 8 EIA-422, TX CLKB (+), TRIB 8 EIA-422, TX CLKA (-), TRIB 8 EIA-422, CTSB (+), TRIB 8 EIA-422, CTSA (-), TRIB 8 GROUND EIA-232, TX CLK, TRIB 7 EIA-232, TX DAT, TRI 7 EIA-232, CTS, TRIB 7 EIA-422, TX DATB (+), TRIB 7 EIA-422, TX DATA (-), TRIB 7 EIA-422, TX CLKB (+), TRIB 7 EIA-422, TX CLKA (-) TRIB 7 EIA-422, CTSB (+),TRIB 7 EIA-422, CTSA (-), TRIB 7 GROUND EIA-232, TX CLK, TRIB 6 EIA-232, TX DAT, TRI 6 EIA-232, CTS, TRIB 6 EIA-422, TX DATB (+),TRIB 6 EIA-422, TX DATA (-), TRIB 6 EIA-422, TX CLKB (+), TRIB 6 EIA-422, TX CLKA (-), TRIB 6 EIA-422, CTSB (+), TRIB 6 EIA-422, CTSA (-), TRIB 6 Pin # 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Circuit GND B_TC232_5 B_TD232_5 B_CTS232_5 B_TD422B_5 B_TD422A_5 B_TC422B_5 B_TC422A_5 B_CTS422B5 B_CTS422A5 GND B_TC232_4 B_TD232_4 B_CTS232_4 B_TD422B_4 B_TD422A_4 B_TC422B_4 B_TC422A_4 B_CTS422B4 B_CTS422A4 GND B_TC232_3 B_TD232_3 B_CTS232_3 B_TD422B_3 B_TD422A_3 B_TC422B_3 B_TC422A_3 B_CTS422B3 B_CTS422A3 GND B_TC232_2 B_TD232_2 B_CTS232_2 B_TD422B_2 B_TD422A_2 B_TC422B_2 B_TC422A_2 B_CTS422B2 B_CTS422A2 GND B_TC232_1 B_TD232_1 B_CTS232_1 B_TD422B_1 B_TD422A_1 B_TC422B_1 B_TC422A_1 B_CTS422B1 B_CTS422A1 Description GROUND EIA-232, TX CLK, TRIB 5 EIA-232, TX DAT, TRIB 5 EIA-232, CTS, TRIB 5 EIA-422, TX DATB (+), TRIB 5 EIA-422, TX DATA (-), TRIB 5 EIA-422, TX CLKB (+), TRIB 5 EIA-422, TX CLKA (-), TRIB 5 EIA-422, CTSB (+), TRIB 5 EIA-422, CTSA (-), TRIB 5 GROUND EIA-232, TX CLK, TRIB 4 EIA-232, TX DAT, TRI 4 EIA-232, CTS, TRIB 4 EIA-422, TX DATB (+), TRIB 4 EIA-422, TX DATA (-), TRIB 4 EIA-422, TX CLKB (+), TRIB 4 EIA-422, TX CLKA (-), TRIB 4 EIA-422, CTSB (+), TRIB 4 EIA-422, CTSA (-), TRIB 4 GROUND EIA-232, TX CLK, TRIB 3 EIA-232, TX DAT, TRI 3 EIA-232, CTS, TRIB 3 EIA-422, TX DATB (+), TRIB 3 EIA-422, TX DATA (-), TRIB 3 EIA-422, TX CLKB (+), TRIB 3 EIA-422, TX CLKA (-), TRIB 3 EIA-422, CTSB (+), TRIB 3 EIA-422, CTSA (-), TRIB 3 GROUND EIA-232, TX CLK, TRIB 2 EIA-232, TX DAT, TRI 2 EIA-232, CTS, TRIB 2 EIA-422, TX DATB (+), TRIB 2 EIA-422, TX DATA (-), TRIB 2 EIA-422, TX CLKB (+), TRIB 2 EIA-422, TX CLKA (-), TRIB 2 EIA-422, CTSB (+), TRIB 2 EIA-422, CTSA (-), TRIB 2 GROUND EIA-232, TX CLK, TRIB 1 EIA-232, TX DAT, TRIB 1 EIA-232, CTS, TRIB 1 EIA-422, TX DATB (+), TRIB 1 EIA-422, TX DATA (-), TRIB 1 EIA-422, TX CLKB (+), TRIB 1 EIA-422, TX CLKA (-), TRIB 1 EIA-422, CTSB (+), TRIB 1 EIA-422, CTSA (-), TRIB 1 Rev. 3 SMS-301 Redundancy Switch Theory of Operation Table 4-13. Switch Control Interface (J16) Pin No. 1 20 2 21 3 22 4 23 5 24 6 25 7 26 8 27 9 28 10 29 11 30 12 31 13 32 14 33 15 34 16 35 17 36 18 37 19 Rev. 3 Name SCL SDA Spare 11 Spare 10 Spare 9 Spare 8 Spare 7 Spare 6 Spare 5 Spare 4 Spare 3 Spare 2 Spare 1 DMDONL MODONL /B_DF /A_DF /B_MF /A_MF ID_5 ID_4 ID_3 ID_2 ID_1 GND GND GND GND GND -12V -12V +12V +12V +5V +5V +5V +5V Function Serial Clock Serial Data No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection No Connection Demod Online Mod Online Modem B Demod Fault Modem A Demod Fault Modem B Mod Fault Modem A Mod Fault Interface Board ID Interface Board ID Interface Board ID Interface Board ID Interface Board ID Ground Ground Ground Ground Ground -12VDC -12VDC +12VDC +12VDC +5VDC +5VDC +5VDC +5VDC 4-11 Theory of Operation SMS-301 Redundancy Switch This page is intentionally left blank. 4-12 Rev. 3 5 Chapter 5. MAINTENANCE This chapter provides the following information: • • 5.1 Test Points and LEDs Fault Isolation Software Revisions The installation of revised controller software may be necessary to implement additions or enhanced features and/or corrective action. The control software resides in a programmable device inside the one unit (1U) switch control chassis (AS/6051). Rev. 3 5-1 Maintenance SMS-301 Redundancy Switch Remove and replace U30 and/or U32 on printed circuit assembly as follows: When replacing the 1:1 switch software, the previous switch configuration and loaded modem configurations will be lost. CAUTIO N 1. Disconnect power supply from the 1:1 switch. 2. Disconnect and remove 1:1 switch from equipment rack. 3. Remove top cover fasteners and cover. 4. Remove and replace U30 and/or U32 on printed circuit assembly, AS/5950. U30 and U32 are socketed devices. 5. Replace cover and fasteners. 6. Position and reconnect the 1:1 switch in rack. 7. Reconnect power supply to the 1:1 switch. 8. Enter desired 1:1 switch configuration. 9. Load all modems from Load/Verify menu or remote terminal. 10. Resume Auto mode as required. 5-2 Rev. 3 SMS-301 Redundancy Switch 5.2 Maintenance Test Points and LEDs Test points and LEDs are included on the M&C board for quick troubleshooting references. LEDs are visual references. Test points are used when additional troubleshooting is required. Refer to Table 5-1 for a list of LEDs and their functions. Table 5-1. LED Functions Function Demodulator A On-line Demodulator B On-line Modulator A On-line Modulator B On-line Transmit Fault Receive Fault System Fault Stored Fault Power Supply 1 Power Supply 2 Auto Mode Manual Mode Rev. 3 Color Green Green Green Green Red Red Red Yellow Green Green Green Yellow 5-3 Maintenance 5.3 SMS-301 Redundancy Switch Fault Isolation System faults are reported in the Fault menu. Refer to Table 5-2 for guidelines to isolate problems, and the appropriate action(s) to be taken. Table 5-2. Fault Isolation, 1:1 Switch Fault Battery/Clock +12 Volt Supply Fault +5 Volt Supply Fault Description Corrupted non-volatile memory detected after hard reset or power-up. Set when power supply voltage(s) are out-of-tolerance. Power Supply #1 Fault Power Supply #2 Fault Set when power supply voltage(s) are out-of-tolerance. Controller Fault M&C controller error detected on power-up. Modem fails to respond to 1:1 switch commands on the modem remote bus, J13. Modem COM Link Mod/Demod Verify Error Module Fault 5-4 Results from inconsistencies between configuration stored in 1:1 switch and configuration reported by modem. Internal I2C bus failure. Action 1. Replace lithium backup battery. 2. Replace M&C board if fault still occurs after battery replacement. 1. Check AC power cord. 2. Check for blown fuse(s) in AC entry module. 3. Replace faulted power supply. 1. Check AC power cord. 2. Check for blown fuse(s) in AC entry module. 3. Replace faulted power supply. Replace M&C board. 1. Verify modem communications parameters (including address assignments) agree with 1:1 switch configuration. 2. If single modem failure, check modem connector and modem. 3. If complete modem failure, check 1:1 switch connector and remote cable. Reload modem configuration from Modem Control, Utility menu. 1. Replace M&C board. 2. If problems persists, replace connector 1:1 switch board. Rev. 3 A Appendix A. REMOTE CONTROL OPERATION This appendix describes the protocol and command structure for remote control and status monitoring of the 1:1 Redundancy Switch. • • A.1 Firmware number: FW/6055-1F and FW/6056 Software version: 1.1.7 General Remote controls and status information are transferred via an EIA-485 (optional EIA-232) serial communications link. Commands and data are transferred on the remote control communications link as US ASCII-encoded character strings. The remote communications link is operated in a half-duplex mode. Communications on the remote link are initiated by a remote controller or terminal. The 1:1 switch never transmits data on the link unless it is commanded to do so. Command and status parameter selection will be determined by whether the backup modem switching mode has been configured as Independent or Dependent. The 1:1 switch will default to Independent mode after a cold startup or hard reset has been initiated. Rev. 3 A-1 Remote Control Operation A.2 SMS-301 Redundancy Switch Message Structure The ASCII character format used requires 11 bits/character: • • • • 7 information bits 2 stop bits 1 parity bit (Odd/Even) 1 start bit Messages on the remote link fall into the categories of commands and responses. Commands are messages which are transmitted to a switch, while responses are messages returned by a switch in response to a command. The general message structure is as follows: • • • • A.2.1 Start Character Device Address Command/Response End of Message Character Start Character A single character precedes all messages transmitted on the remote link. This character flags the start of a message. This character is: • • “<” for commands “>” for responses For any command that the 1:1 switch is passing through, an additional start character is added to the beginning of the message. This informs the operator that this command was a relayed command. This is true for the modem control link and the operator’s communications link. In order for a command to be relayed through the 1:1 switch, the address in the message must match the address that has been assigned to Modem A or Modem B. A-2 Rev. 3 SMS-301 Redundancy Switch A.2.2 Remote Control Operation Device Address The device address is the address of the 1:1 switch which is designated to receive a transmitted command, or which is responding to a command. Valid device addresses are 1 to 3 characters long, and in the range of 1 to 255. Address 0 is reserved as a global address which simultaneously addresses all devices on a given communications link. Devices do not acknowledge global commands. Each 1:1 switch which is connected to a common remote communications link must be assigned its own unique address. Addresses are software selectable at the modem, and must be in the range of 1 to 255. A.2.3 Command/Response The command/response portion of the message contains a variable-length character sequence which conveys command and response data. If a 1:1 switch receives a message addressed to it which does not match the established protocol or cannot be implemented, a negative acknowledgment message is sent in response. This message is: >add/?ER2_invalid parameter'cr''lf'] (Error message for a recognized command which cannot be implemented or has parameters which are out of range.) >add/?ER3_unrecognizable command'cr''lf'] (Error message for unrecognizable command or bad command syntax.) >add/?ER4_modem in local mode'cr''lf'] (Modem in local error; send the REM command to go to remote mode.) >add/?ER5_hard coded parameter'cr''lf'] (Error message indicating that the parameter is hardware dependent and may not be changed remotely.) >add/?ER6_budy'cr''lf'] (Error message indicating that the command sent cannot be carried out because local processing is utilizing the modem control bus.) Rev. 3 A-3 Remote Control Operation SMS-301 Redundancy Switch The 1:1 switch does not respond to erred communications (i.e., parity and framing errors.) Note: “add” is used to indicate a valid 1 to 3 character device address in the range between 1 and 255. A.2.4 End Character Each message is ended with a single character which signals the end of the message: • • A-4 “cr” “]” Carriage return character for commands End bracket for responses Rev. 3 SMS-301 Redundancy Switch A.3 Operational Mode Remote Control Operation Configuration Commands/Responses Command: Response: <add/MODE_xxxxxx'cr' >add/MODE_xxxxxx'cr''lf'] Status: Response: <add/MODE_'cr' >add/MODE_xxxxxx'cr''lf'] Set Online Modulator (Independent Switching) Command: Response: <add/MOL_x'cr' >add/MOL_x'cr''lf'] Status: Response: <add/MOL_'cr' >add/MOL_x'cr''lf] Set Online Demod (Independent Switching) Command: Response: <add/DOL_x'cr' >add/DOL_x'cr''lf'] Status: Response: <add/DOL_'cr' >add/DOL_x'cr''lf] Set Online Modem (Dependent Switching) Command: Response: <add/MOL_x'cr' >add/MOL_x'cr''lf'] Status: Response: <add/MOL_'cr' >add/MOL_x'cr''lf] Command: Response: <add/MA_yyy'cr' >add/MA_yyy'cr''lf'] Status: Response: <add/MA_'cr' >add/MA_yyy'cr''lf'] Command: Response: <add/DA_yyy'cr' >add/DA_yyy'cr''lf'] Status: Response: <add/DA_'cr' >add/DA_yyy'cr''lf'] Command: Response: <add/SM_yyy'cr' >add/SM_yyy'cr''lf'] Status: Response: <add/SM_'cr' >add/SM_yyy'cr''lf'] Modem Online Delay (Dependent Switching) Command: Response: <add/MD_yyy.y'cr' >add/MD_yyy.y'cr''lf] Status: Response: <add/MD_'cr' >add/MD_yyy.y'cr''lf] Modulator Online Delay (Independent Switching) Command: Response: <add/MD_yyy.y'cr' >add/MD_yyy.y'cr''lf] Status: Response: <add/MD_'cr' >add/MD_yyy.y'cr''lf] Where: xxxxxx = AUTO or MANUAL. This command selects the mode of operation for the SMS301. Modulator's Active (Enable) Demod Active (Enable) Switching Mode Selection Rev. 3 (See Note) Notes: 1. If AUTO is selected, the Monitor and Control in the SMS301 controls all switching decisions. 2. If MANUAL is selected, the operator controls all switching decisions via the next 3 following commands. Where: x = A or B (Modulator Online number). This command puts the specified modulator online. Note: Manual Mode Only. (See Note) Where: x = A or B (Demodulator Online number). This command puts the specified demodulator online. Note: Manual Mode Only. (See Note) Where: x = A or B (Modem Online number). This command puts the specified modem online. Note: Manual Mode Only. (See Note) Where: yyy = YES or NO. Note: Manual Mode Only. (See Note) Where: yyy = YES or NO. Note: Manual Mode Only. (See Note) Where: yyy = IND (Independent) or DEP (Dependent). Note: Manual Mode Only. Where: yyy.y = 0.0 to 127.0 seconds (in .5 second increments). Where: yyy.y = 0.0 to 127.0 seconds (in .5 second increments). A-5 Remote Control Operation Demod Online Delay (Independent Switching) A.4 Modem Control Baud Rate SMS-301 Redundancy Switch Command: Response: <add/DD_yyy.y'cr' >add/DD_yyy.y'cr''lf] Status: Response: <add/DD_'cr' >add/DD_yyy.y'cr''lf] Where: yyy.y = 0.0 to 127.0 seconds (in .5 second increments). Modem Communications Configuration Commands/Responses Command: Response: <add/MBR_mmmmm'cr' (See Note) >add/MBR_mmmmm'cr''lf'] Status: Response: <add/MBR_'cr' >add/MBR_mmmmm'cr''lf'] Command: Response: <add/ADD_x_yyy'cr' >add/ADD_x_yyy'cr''lf'] Status: Response: <add/ADD_x'cr' >add/ADD_x_yyy'cr''lf'] Load Modem Config. Command: Response: <add/LMC_x'cr' >add/LMC_x'cr''lf'] Automatic Verify Enable Command: Response: <add/AVE_xxx'cr' >add/AVE_xxx'cr''lf'] Status: Response: <add/AVE_xxx'cr' >add/AVE_xxx'cr''lf'] Modem Address Where: mmmmm = 9600 or 19200. Note: Manual Mode Only. Where: x = A to B (modem number). A-6 yyy = 0 to 255 (modem address, 0 puts modem out of service). (See Note) Where: x = A or B (modem number). Note: Manual Mode Only. Where: xxx = ON (Enable) or OFF (Disable). Rev. 3 SMS-301 Redundancy Switch A.5 Time Of Day Date Remote Operation Remote Control Operation System Commands/Responses Command: Response: <add/TIME_hh:mmxx'cr' >add/TIME_hh:mmxx'cr''lf'] Status: Response: <add/TIME_'cr' >add/TIME_hh:mmxx'cr''lf'] Command: Response: <add/DATE_mm/dd/yy'cr' >add/DATE_mm/dd/yy'cr''lf'] Status: Response: <add/DATE_'cr' >add/DATE_mm/dd/yy'cr''lf'] Command: Response: <add/REM_'cr' >add/REM_'cr''lf'] Where: hh = 1 to 12 (hours). mm = 00 to 59 (minutes). xx = AM or PM. Where: mm = 1 to 12 (month). dd = 1 to 31 (day). yy = 00 to 99 (year). Configures the SMS301 for remote operation. The SMS301 will respond to any status request at any time. However, the SMS301 must be in 'Remote Mode' to change configuration parameters remotely. Clear Stored Faults Command: Response: <add/CLSF_'cr' >add/CLSF_'cr''lf'] This command is used to clear all stored faults logged by the SMS301. Power Supply Monitor Command: Response: <add/PS_xxx'cr' >add/PS_xxx'cr''lf'] Where: xxx = 1 (monitor power supply #1), 2 (monitor power supply #2), 1&2 (monitor power supply #1 & #2). Status: Response: <add/PS_'cr' >add/PS_xxx'cr''lf'] Command: Response: <add/SMC_n'cr' >add/SMC_n'cr''lf'] Save Switch Config. Where: n = 1, 2, 3, 4, or 5 (stored configuration number). This command saves the current switch configuration for recall at a later time using the "RMC_" command. Up to five different switch configurations can be saved. Recall Switch Config. Rev. 3 Command: Response: <add/RMC_n'cr' >add/RMC_n'cr''lf'] Where: n = 1, 2, 3, 4, or 5 (stored configuration number). This command causes the switch to be reprogrammed with configuration parameters previously saved using the "SMC_" command. One of five saved configurations can be specified. A-7 Remote Control Operation A.6 Modulator Config. Status SMS-301 Redundancy Switch Status Commands/Responses Command: Response: <add/MCS_'cr' >add/MCS_'cr' MODE_xxxxxx'cr' SM_xxx'cr' MA_yyy'cr' MD_yyy.y'cr' ADD_A_yyy'cr' ADD_B_yyy'cr''lf'] Operation Mode Switching Mode Modulator's Active Modulator/Modem Delay A Modem Address B Modem Address The Modulator configuration status command causes a block of data to be returned by the SMS301. Note: *1* = dependent mode only, *2* = independent mode only. Demod Config. Status Command: Response: <add/DCS_'cr' >add/DCS_'cr' MODE_xxxxxx'cr' SM_xxx'cr' DA_yyy'cr' + DD_yyy.y'cr' # MD__yyy.y'cr' ADD_A_yyy'cr' ADD_B_yyy'cr''lf'] Operation Mode Switching Mode Demodulator's Active Demodulator Delay Modem Delay A Modem Address B Modem Address The Demodulator configuration status command causes a block of data to be returned by the SMS301. + Note: Status only returned in Independent Mode. # Note: Status only returned in Dependent Mode. Modulator Status Command: Response: <add/MS_'cr' >add/MS_'cr' MOD_A_xxx'cr' MOD_B_xxx'cr''lf'] A Modulator Status (OK/FLT) B Modulator Status (OK/FLT) The Modulator status is returned as a block of data which provides fault information of all 'active' Modulators. Note: Response shown is for a system with all possible modulators active. Only active modulator status will be reported. Demod Status Command: Response: <add/DS_'cr' >add/DS_'cr' DMD_A_xxx'cr' DMD_B_xxx'cr''lf'] A Demodulator Status (OK/FLT) B Demodulator Status (OK/FLT) The Demodulator status is returned as a block of data which provides fault information of all 'active' Demodulators. Note: Response shown is for a system with all possible demodulators active. Only active modulator status will be reported. A-8 Rev. 3 SMS-301 Redundancy Switch A.7 Fault Summary Status Commands/Responses Operational Faults Status Command: Response: System Fault Status Summary Command: Response: Rev. 3 Remote Control Operation <add/OFS_'cr' >add/OFS_'cr' MOD_xxx'cr' DMD_xxx'cr' SFLT_xx'cr''lf'] TX Operational Status (OK/FLT) RX Operational Status (OK/FLT) Number of Stored Faults Logged (0 to 10) <add/SFS_'cr' >add/SFS_'cr' M&C_xxx'cr' INT_xxx'cr' BAT_xxx'cr' +5_xxx'cr' +12_xxx'cr' PS1_xxx'cr' PS2_xxx'cr' COM_xxx'cr' MVFY_xxx'cr' DVFY_xxx'cr' SFLT_xx'cr''lf'] Monitor & Control Module (OK/FLT) Data Interface/Overhead Module (OK/FLT) Battery/Clock (OK/FLT) +5V Power Supply (OK/FLT) +12V Power Supply (OK/FLT) Power Supply #1 (OK/FLT) Power Supply #2 (OK/FLT) Modem Communications (OK/FLT) Mod Config Verify (OK/FLT) Demod Config Verify (OK/FLT) Number of stored faults logged (0 to 10) A-9 Remote Control Operation A.8 SMS-301 Redundancy Switch Stored Faults Information on stored faults is returned when requested. If no stored fault exists for a given fault number, the words “NO Fault” will be returned instead of the normal time/date status information. The following symbols are commonly used to define the stored faults status commands: • • • • • • • Operational Stored Faults Command: Response: System Stored Faults Command: Response: A-10 # hh mm ss MM DD YY Fault number (0 to 9). “0” is the first fault stored. Hours in 24-hr. format. Minutes. Seconds. Month. Day. Year. <add/OSF_#'cr' >add/OSF_# hh:mm:ss MM/DD/YY'cr' MOD_xxx'cr' DMD_xxx'cr''lf'] TX Operational Status (OK/FLT) RX Operational Status (OK/FLT) <add/SSF_#'cr' >add/SSF_# hh:mm:ss MM/DD/YY'cr' M&C_xxx'cr' INT_xxx'cr' BAT_xxx'cr' +5_xxx'cr' +12_xxx'cr' PS1_xxx'cr' PS2_xxx'cr' COM_xxx'cr' MVFY_xxx'cr' DVFY_xxx'cr''lf'] Monitor & Control Module (OK/FLT) Data Interface/Overhead Module (OK/FLT) Battery/Clock (OK/FLT) +5V Power Supply (OK/FLT) +12V Power Supply (OK/FLT) Power Supply #1 (OK/FLT) Power Supply #2 (OK/FLT) Modem Communications (OK/FLT) Mod Config Verify (OK/FLT) Demod Config Verify (OK/FLT) Rev. 3 SMS-301 Redundancy Switch Bulk Consol. Status Command: Response: <add/BCS_'cr' >add/BCS_p1,p2,p3, . . . pn'cr''lf'] Remote Control Operation This command causes bulk switch status to be returned. To reduce the length of the response, message parameter data are returned without identifiers. However, parameter identification can be determined by order of return. Each status parameter is terminated with a ',' (comma) except for the last parameter which has the standard message termination sequence ('cr''lf']). Most of the data returned is formatted the same way as the single command status request (refer to the appropriate portions of this document in preceding sections). Additional configuration status of new options and features will always be appended to the end. Where 'pn' is the last parameter returned. Parameter Number 1 Parameter Name (Command Reference) Operation Mode (ref. "MODE_" command). Description p1 = n, where 'n' is '0' (MANUAL), '1' (AUTO). 2 Switching Mode (ref. "SM_" command). p2 = n, where 'n' is '0' (INDEPENDENT), '1' (DEPENDENT). 3 Modulator's Active (ref. "MA_" command). p3 = n, where 'n' is '0' (DISABLED), '1' (ENABLED). Demodulator's Active (ref. "DA_" command). p4 = n, where 'n' is '0' (DISABLED), '1' (ENABLED). Modulator/Modem Delay (ref. "MD_" command). p5 = nnn.n, delay in seconds. Demodulator Delay (ref. "DD_" command). p6 = nnn.n, delay in seconds. 4 5 6 7 8 9 10 11 12 13 14 Rev. 3 Power Supply Monitor (ref. "PS_" command). p7 = n, where 'n' is '0' for Supply #1, '1' for Supply #2, and '2' for supply #1 and #2. Modem A Address (ref. "ADD_A" command). p8 = nnn, 0 to 255 is the Modem A address. Modem B Address (ref. "ADD_B" command). p9 = nnn, 0 to 255 is the Modem B address. MODEM REMOTE/LOCAL mode. p10 = n, where 'n' is '0' (LOCAL), '1' (REMOTE). Auto verify mode. (ref. "AVE_" command). p11 = n, where 'n' is '0 (DISABLED), '1' (ENABLED). Modem Control Baud Rate (ref. MBR_command). p12 = n, where 'n' is '0' (9600), '1' (19200). Modulator/Modem Online (ref. "MOL_" command). p13 = n, where 'n' is '0' (Mod A), '1' (Mod B). Demodulator Online (ref. "DOL_" command). p14 = n, where 'n' is '0' (Demod), '1' (Demod B). (Note this command will always respond with the current demod status.) A-11 Remote Control Operation Equipment Type Command: Response: SMS-301 Redundancy Switch <add/ET_'cr' >add/ET_tttttttt_xxx.yyy.zzz'cr''lf'] Where: tttttttt = Equipment Type. xxx.yyy.zzz = Software Version number (0.0.0 to 999.999.999). This command returns the equipment type and the software version of the addressed device. Monitor & Control Firmware Information Command: Response: <add/MCFI_'cr' >add/MCFI_'cr' VER_xxx.yyy.zzz'cr' FW/nnnnnn-ddr'cr' mm/dd/yy'cr''lf'] Where: xxx.yyy.zzz = Software version number (0.0.0 to 999.999.999). nnnnnn = Firmware number (0 to 999999). dd = Firmware dash number (0 to 99). r = Firmware revision (-, or A to Z). Boot M&C Firmware Information Command: Response: <add/BFI_'cr' >add/BFI_'cr' VER_xxx.yyy.zzz'cr' FW/nnnnnn-ddr'cr' mm/dd/yy'cr''lf'] Where: xxx.yyy.zzz = Software version number (0.0.0 to 999.999.999). nnnnnn = Firmware number (0 to 999999). dd = Firmware dash number (0 to 99). r = Firmware revision (-, or A to Z). A-12 Rev. 3 B Appendix B. SDM-300/-300A SYSTEM INSTALLATION This appendix describes the system installation for the following configurations: • • • • • B.1 25-pin, EIA-422/-530, EIA-232, V.35, G.703 34-pin, EIA-422/-449, V.35, G.703 37-pin, EIA-422/-449, LVDS-DVB, V.35, G.703 50-pin, ASYNC, IBS, IDR, D&I 100-pin, RS-301 Switch System Installation The system installation can vary for 25-pin to 100-pin configurations. This manual will not describe the possible installation of mixed data interfaces. However, any problem arising from the installation should be addressed to Comtech EFData Customer Support department. Rev. 3 B–1 SDM-300/-300A System Installation B.1.1 SMS-301 Redundancy Switch System Installation (Standard Configuration) Refer to Table B-1 for cable assemblies applicable to the standard configuration. Table B-1. Standard Configuration Cabling Item No. 1A 1B 1C 1D Part No. PL/3588 PL/0725 PL/0730 PL/0737-4 (PL/5665-4) PL/0737-6 (PL/5665-8) PL/0737-8 (PL/566-12) Description Data Cable, 25-pin Data Cable, 34-pin Data Cable, 37-pin Data Cable, 50-pin, 4 feet Data Cable, 50-pin, 8 feet Data Cable, 50-pin 8 feet Notes: 1. 2 3 4 PL/0813-4 PL/0813-8 PL/6239 PL/6051-1 Data Cable, 50-pin is available with right angle connector, PL/0737R-X. 2. Data Cable, 50-pion is available with ECL interface, PL/4807-X. BNC Cable, 48.0 ± 1.5 inches (length) BNC Cable, 96.0 ± 3.0 inches (length) Cable Assy, Remote Control with Termination Power Cable Assemblies Note: Alternate part is provided in parenthesis. Refer to Figure B-1 for cabling the standard configuration. 1. Mount the SMS-301 1:1 switch in a standard equipment rack. Secure with four bolts. 2. Connect the data interface connector (Figure B-1) as follows: a. Connect the “COMM” data interface connector (J1) to the customerfurnished equipment, using a customer-furnished cable assembly. b. Connect the “A” data interface connector (J2) to the prime modulator Data I/O interface connector, using applicable data cable listed in Table B-1, items 1A through 1D. c. Connect “B” data interface connector (J3) to the backup modulator data I/O interface connector using applicable data cable listed in Table B-1, items 1A through 1D. 3. Connect REMOTE connector at the prime modulator, bacvkup modulatotr, to the COMM connector at the 1:1 switch, using PL/6239 cable assembly. Connect to customer-furnished equipment. B–2 Rev. 3 SMS-301 Redundancy Switch SDM-300/-300A System Installation S E LE C T IT E M 1A T H R O U G H 1D EX RE F J9 AUX 1 J6 REMOTE FAULT J7 RX/IF INPUT CP 3 AL ARMS J10 TX /IF O U T P U T CP2 CP 1 3 2 2 3 J6 REMOTE S E LE C T IT E M 1A T H R O U G H 1D EX RE F J9 AUX 1 FAULT J7 RX/IF INPUT CP 3 ALARM S J10 T X /IF O U T P UT CP2 CP 1 2 2 To C U ST O M E R ’S E Q U IP M EN T C U ST O M E R F U R N ISH ED To C U ST O M E R ’S E Q U IP M EN T 3 2 2 2 DEM O D J9 A MOD J8 RX IF J7 B J4 TX IF J5 A 2 2 J6 B ! 100 TO 240V 1.5 A 50 TO 60 Hz J14 AC2 STATUS/FAU LT S J12 T2A , 250V AC1 J11 4 4 J10 REM O TE CO NTR OL M O DEM CO M J13 2 To POW ER S U P P LY U P C O N VE RTE R 2 D O W N C O N VE RTE R 2 Figure B-1. System Installation (Standard Configuration) Rev. 3 B–3 SDM-300/-300A System Installation SMS-301 Redundancy Switch 4. Connect MOD side of 1:1 switch as follows: a. Connect “TX IF” connector (J4) to IF IN connector (J7) on the rear panel of the up converter, using Cable PL/0813-X. b. Connect the “A” connector (J5) to the prime modulator TX IF OUT connector (CP1), using Cable PL/0813-X. c. Connect the “B” connector (J6) to the backup modulator TX IF OUT connector (CP1), using Cable PL/0813-X. 5. Connect DEMOD side of 1:1 switch as follows: a. Connect the “B” connector (J7) to the backup modulator “RX IF IN” connector (CP2), using Cable PL/0813-X. b. Connect “RX IF” connector (J8) to the down converter ‘IF OUT” connector (J7), using Cable PL/0813-X. c. Connect the “A” connector (J9) to the prime modulator “RX IF IN” connector (CP2), using Cable PL/0813-X. 6. Connect AC power to AC1 (J11) and AC2 (J12) with power cables PL/6051-1. a. If two AC power sources are available, connect AC1 and the prime modulator to one AC source and AC2 and the backup modulator to the other AC source. b. If the DC power option is used, connect the DC voltage to the terminal blocks is a similar manner. B–4 Rev. 3 SMS-301 Redundancy Switch B.1.2 SDM-300/-300A System Installation System Installation (RS-301 Switch Installed) After unpacking the 1:1 switch and the RS-301 Remote Switch, refer to Table B-2 and the following instructions. Table B-2. RS-301 Configuration Cabling Item No. 1 2 3 4 B.1.3 Part No. PL/CA90101G100-4 PL/0813-4 PL/0813-8 PL/6239 PL/6051-1 Description Data Cable, 100-pin BNC Cable, 48.0 ± 1.5 inches (length) BNC Cable, 96.0 ± 3.0 inches (length) Cable Assy, Remote Control with Termination Power Cable Assemblies Connect System Installation with RS-301 Switch Refer to Figure B-2 for cabling with the RS-301 Switch installed. 1. Mount the 1:1 switch in a standard equipment rack with four bolts. 2. Mount the remote switch (RS-301) in the same rack using four bolts. 3. Connect the Data I/O interface as follows: a. Connect the “RREMOTE SWITCH CONTROL” connector (J1) to the “SWITCH CONTROL INTERFACE” connector (J16) on the RS–301 switch, using cabling PL/CA90101G100-4. b. Connect the ‘MODEM A DATA” connectopr (J14) on the RS-301 switch to the prime modulator Data I/O connector, using Cable PL/CA90101G100-4 c. Connect the “MODEM B DATA” connector (J15) on the remote switch to the backup modulator Data connector, using Cabling PL/90101G100-4. 4. Connect the MOD side of the 1:1 switch as follows: a. Connect the “TX IF” BNC connector (J4) in the 1:1 switch rear panel to the top converter IF IN (J7), using Cable PL/0813-X. b. Connect the “A” BNC connector (J5) to the prime modem “TX IF OUT” (CP1), using Cable PL/0813-X. c. Connect the “B” BNC connector (J6) to the backup modem “TX IF OUT” (CP1), using Cable PL/0813-X. Rev. 3 B–5 SDM-300/-300A System Installation SMS-301 Redundancy Switch 1 S E LE C T IT E M 1 A T H R O U G H 1 D J6 R EMO TE EX RE F J9 AU X 1 FAULT J7 RX/IF INPUT CP 3 AL A RM S J1 0 T X /IF O U TP UT CP2 CP1 3 2 2 3 1 J6 REMOTE S E LE C T IT E M 1 A T H R O U G H 1 D EX RE F J9 AUX 1 FAULT J7 R X/IF IN PUT CP 3 AL ARM S J 10 T X /I F O U T P U T CP2 CP1 2 2 3 2 2 2 DEM O D J9 A M OD J8 RX IF J7 B J4 TX IF J5 A 2 2 J6 B ! 100 TO 240V 1.5 A 50 TO 60 H z J14 AC2 STATU S/FA ULTS J12 T2A, 250V AC1 J11 4 4 J10 REM O TE CO NTROL M ODE M CO M J13 1 2 To POW ER S U PP LY To C U S TO M ER ’S E Q U IPM E N T 1 SW IT CH CONTROL INTERFACE M ODEM A DATA M ODEM B DATA J14 J15 J16 R S -3 0 1 F R O N T PA N E L 1 2 2 D OW N C O NVERTER TR IB 1 D ATA TR IB 2 D ATA TR IB 3 D ATA TR IB 4 D ATA TR IB 5 D ATA TR IB 6 D ATA TR IB 7 D ATA TR IB 8 D ATA AUX J1 J2 J3 J4 J5 J6 J7 J8 J9 R S -301 To C U S TO M ER ’S E Q U IPM E N T 3 Figure B-2. System Installation (RS-301 Installed) B–6 Rev. 3 SMS-301 Redundancy Switch SDM-300/-300A System Installation 5. Connect the DEMOD side of the 1:1 switch as follows: a. Connect the “RX IF” BNC connector (J8) to the down converter “IF OUT” (J7), using Cable PL/0813-X. b. Connect the “A” BNC connector (J9) to the prime modem “RX IF IN” , using Cable PL/0813-X. c. Connect the “B” BNC (J7) to the backup modem “RX IF IN”, using Cable PL/ 0813-X. 6. Connect the customer-equipment (as required) to the remote switch “TRIBUTARY’ cuonnectors, using Cable PL/6239. 7. Connect AC power to AC1 (J11) and AC2 (J12) with power cable assemblies PL/6051-1. a. If two AC power sources are availble, connect AC1 and the prime modem to one AC source, and AC2 and the backup modem to the other AC source. b. If the DC power option is used, connect the DC voltage to the terminal blocks in a similar manner. 8. Connect the remote terminal to the “REMOTE CONTROL” (J10) connector, REMOTE (J6) on the priome modulator and REMOTE (J6) on the backup modulator using Cable PL/6239. Rev. 3 B–7 SDM-300/-300A System Installation SMS-301 Redundancy Switch This page is intentionally left blank. B–8 Rev. 3 C Appendix C. SDM-2020 System Installations This appendix describes the installation options available for the SMS-301 1:1 Switch and the SDM-2020 Satellite Modulator. C.1 Installation Options C.1.1 Connect Low Voltage Differential Signal Interface (Optional) Note: The section defines the requirements of the Low Voltage Differential Signal (LVDS) data interface for video and high-speed data applications used with the SDM-2020 Satellite Modulator. C.1.1.1 Description The 1:1 switch LDVS interface is a plug-in module that interfaces with the SDM-2020 Satellite Modulator. The interface uses serial and parallel clock and data formats, where as the SDM-2020 LVDS and Digital Video Broadcast (DVB) interfaces are either serial or parallel format. The difference between the LVDS and DVB (EIA-422) interfaces are the drivers and receivers. Rev. 3 • Parallel format: The interface is a DVB 8 bit parallel synchronous (LVDS) or EIA-422 (DVB). • Serial format: MSB (Data 7) is used for serial data and clock. C–1 SDM-2020 System Installation SMS-301 Redundancy Switch The interface operates to the specifications described in Table C-1. Table C-1. LVDS/DVB Specifications Interface Type Data Rate Serial Parallel Connectors Electrical Properties Signal Types C–2 General Specification LVDS/DVB Synchronous Serial/Parallel EIA-422 DVB 1.5 to 32 Mbit/s 0.1875 to 12.5 Mbit/s 37-pin D female for TX and RX data Per TIA/EIA-644 TX, TX Clock, TX Data, Data Valid, and SYNC per TM1449 Rev. 3 SMS-301 Redundancy Switch C.1.1.2 SDM-2020 System Installation Connect to SDM-2020 Modulator with LVDS Interface Refer to Figure C-1. 1. Connect the “COMM” data interface connector (J1) to the DTE equipment. Note: Equivalent cable shall be computer grade, 100Ω, incorporating twisted and shielded pairs. Typical length shall be ≤ 16 feet (5 meters). 2. Connect the “A” data interface connector (J2) to the prime SDM-2020 Modulator “TX IN” (J4) connector and “AUX” (J5) connector using Cable (CA/6217) or equivalent. 3. Connect the “B” data interface connector (J3) to the backup SDM-2020 Modulator “TX IN” (J4) connector “AUX” (J5) connector using Cable (CA/6217) or equivalent. S D M -20 2 0 S AT E L L ITE M O D U L ATO R J4 TX IN J3 R X O U T J3 J4 J5 A U X J5 S D M -20 2 0 S AT E L L ITE M O D U L ATO R J3 R X O U T J4 TX IN J5 A U X CABLE (PL/6217) J2 (A) CABLE (PL/6217) J3 (B) SMS-301 1:1 REDUNDANCY SWITCH (S TA N D A R D C O N F IG U R AT IO N ) Figure C-1. Connect to SDM-2020 Modulator with LVDS Interface Rev. 3 C–3 SDM-2020 System Installation C.1.2 SMS-301 Redundancy Switch Connect to SDM-2020 Satellite Modulator with EIA-422 Interface Note: The section defines the requirements of the EIA-422 data interface for video and high-speed data applications used with the SDM-2020 Satellite Modulator. This interface uses serial format only. C.1.2.1 Description The SMS-301 data interface is a plug-in module that interfaces with the SDM-2020 Satellite Modulator. The interface used EIA-530 serial format. Specifications are as referenced herein: • EIA-422, Electrical Characteristics of Balanced Voltage Digital Interface Circuits • EIA-530, High-Speed 25-Position Interface for data Circuit – Terminating Equipment The interface operates to the specifications described in Table C-1. Table C-2. EIA-422/EIA-530 Specifications Interface Type Data Rate Connectors Electrical Properties Signal Types C–4 General Specification EIA-422/EIA-530 Synchronous (Serial) 1.5 to 18 Mbit/s (Serial) 37-pin D female for serial data Per EIA-422 SD, ST, TT, RS, CS, RD, RT, RR, (CD) Rev. 3 SMS-301 Redundancy Switch C.1.2.2 SDM-2020 System Installation Connect to SDM-2020 Modulator with EIA-422 Interface Refer to Figure C-2. 1. Connect the “COMM” data interface connector (J1) to the DTE equipment. Note: Equivalent cable shall be computer grade, 100Ω, incorporating twisted and shielded pairs. Typical length shall be ≤ 16 feet (5 meters). 2. Connect the “A” data interface connector (J2) to the prime SDM-2020 Modulator “SERIAL” (J4) connector using Cable (CA/6679) or equivalent. 3. Connect the “B” data interface connector (J3) to the backup SDM-2020 Modulator “SERIAL” (J4) connector using Cable (CA/6679) or equivalent Connection to SDM-2020 Satellite Modulator with EIA-422 (DVB) TX Interface (18 Mbit/s Serial Data) Note: The section defines the requirements of the EIA-422 (DVB) TX data interface for video and high-speed data applications used with the SDM-2020 Satellite Modulator. S D M -20 2 0 S AT E L L ITE M O D U L ATO R EIA -530 SE R IA L J4 PA R A LLEL J3 J4 J3 AUX J5 J5 S D M -20 2 0 S AT E L L ITE M O D U L ATO R EIA -530 PA R A LLEL J3 SE R IA L J4 AUX J5 CABLE (PL/6679) CABLE (PL/6679) J2 (A) SMS-301 1:1 REDUNDANCY SWITCH J3 (B) (S TA N D A R D C O N F IG U R AT IO N ) Figure C-2. Connect to SDM-2020 Modulator with EIA-422 Interface Rev. 3 C–5 SDM-2020 System Installation SMS-301 Redundancy Switch C.1.3 Connect to SDM-2020 Sateliite Modulator with EIA-422 DVB TX Interface C.1.3.1 Description The SMS-301 data interface is a plug-in module that interfaces with the SDM-2020 Satellite Modulator. The maximum data rate is 18 Mbit/s for serial data. The SDM-2020 Modulator configured with the EIA-422 data interface is identified as follows: • Parallel Connector (J3) is used for DVB EIA-422 either parallel or serial data. • Serial connector (J3) is for (EIA-530) serial differential data operation. Note: SDM-2020 Modulator with ASI/EIA-422 data interface can be configured using the same instructions as the EIA-422 configuration. The interface operates to the specifications described in Table C-1. Table C-3. EIA-422/EIA-530 Specifications Interface Type Data Rate Connectors Electrical Properties Signal Types C–6 General Specification EIA-422/EIA-530 Synchronous (Serial) 1.5 to 18 Mbit/s (Serial) 37-pin D female for serial data Per EIA-422 SD, ST, TT, RS, CS, RD, RT, RR, (CD) Rev. 3 SMS-301 Redundancy Switch SDM-2020 System Installation The cable pin assignments are specified in Table C-4. Table C-4. Cable Pin Assignments (CA/6217) SMS-301 (DB-37) Pin # 19 37 34 15 33 14 32 13 31 12 30 11 29 10 28 9 27 8 26 7 25 6 1 21 2 22 3 C.1.3.2 Name CLK-A CLK-B SYNC-A SYNC-B VAL-A VAL-B DAT7-A DAT7-B DAT6-A DAT6-B DAT5-A DAT5-B DAT4-A DAT4-B DAT3-A DAT3-B DAT2-A DAT2-B DAT1-A DAT1-B DAT0-A DAT0-B SG REFCLK-A REFCLK-B DF MF Signal Function Master Clock (TT Serial) Synchronized Data Valid Data Bit 7 (Serial Data Bit) Data Bit 6 Data Bit 5 Data Bit 4 Data Bit 3 Data Bit 2 Data Bit 1 Data Bit 0 Signal Ground Reference Clock (ST Serial) DEMOD Fault MOD Fault SDM-2020M DVB Parallel or Serial (J3 DB 25 EIA-422) 1 14 12 25 11 24 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 13 15 Reference Clock or 2 Ground AUX (J5) Pin 2 DB 9 AUX (J5) Pin 6 DB 9 Connect to SDM-2020 Modulator with EIA-422 DVB TX Interface Refer to Figure C-3. 1. Connect the “COMM” data interface connector (J1) to the DTE equipment. Note: Equivalent cable shall be computer grade, 100Ω, incorporating twisted and shielded pairs. Typical length shall be ≤ 16 feet (5 meters). 2. Connect the “A” data interface connector (J2) to the prime SDM-2020 Modulator “SERIAL” (J4) connector and “AUX” (J5) connector using Cable (CA/6217) or equivalent. 3. Connect the “B” data interface connector (J3) to the backup SDM-2020 Modulator “SERIAL” (J4) connector and “AUX” (J5) connector using Cable (CA/6217) or equivalent Rev. 3 C–7 SDM-2020 System Installation SMS-301 Redundancy Switch S D M -2 0 2 0 S AT E L L IT E M O D U L AT O R EIA -530 SER IAL J4 PAR A LLEL J3 J3 J4 A UX J5 J5 S D M -2 0 2 0 S AT E L L IT E M O D U L AT O R EIA -530 PAR A LLEL J3 SER IAL J4 A UX J5 CABLE (PL/6217) CABLE (PL/6217) J2 (A) J3 (B) SMS-301 1:1 REDUNDANCY SWITCH (S TA N D A R D C O N F IG U R AT IO N ) 1 8 M bit/s F or S erial D a ta Figure C-3. Connect to SDM-2020 Modulator with EIA-422 (DVB) TX Interface (18 Mbit/s Serial Data) C–8 Rev. 3 SMS-301 Redundancy Switch C.1.4 SDM-2020 System Installation Connect to SDM-2020 Satellite Modulator with EIA-422 (DVB) TX Interface (100 Mbit/s Parallel Data) Note: The section defines the requirements of the EIA-422 (DVB) TX data interface for video and high-speed data applications used with the SDM-2020 Satellite Modulator. C.1.4.1 Description The SMS-301 data interface is a plug-in module that interfaces with the SDM-2020 Satellite Modulator. The maximum data rate is 100 Mbit/s for parallel data. The SDM-2020 Modulator configured with the EIA-422 data interface is identified as follows: • Parallel Connector (J3) is used for DVB EIA-422 either parallel or serial data. • Serial connector (J3) is for (EIA-530) serial differential data operation. Note: SDM-2020 Modulator with ASI/EIA-422 data interface can be configured using the same instructions as the EIA-422 configuration. Rev. 3 C–9 SDM-2020 System Installation SMS-301 Redundancy Switch The cable pin assignments are specified in Table C-5. Table C-5. Cable Pin Assignments (CA/6217) SMS-301 (DB-37) Pin # 19 37 34 15 33 14 32 13 31 12 30 11 29 10 28 9 27 8 26 7 25 6 1 21 2 22 3 C.1.4.2 Name CLK-A CLK-B SYNC-A SYNC-B VAL-A VAL-B DAT7-A DAT7-B DAT6-A DAT6-B DAT5-A DAT5-B DAT4-A DAT4-B DAT3-A DAT3-B DAT2-A DAT2-B DAT1-A DAT1-B DAT0-A DAT0-B SG REFCLK-A REFCLK-B DF MF Signal Function Master Clock (TT Serial) Synchronized Data Valid Data Bit 7 (Serial Data Bit) Data Bit 6 Data Bit 5 Data Bit 4 Data Bit 3 Data Bit 2 Data Bit 1 Data Bit 0 Signal Ground Reference Clock (ST Serial) DEMOD Fault MOD Fault SDM-2020M DVB Parallel or Serial (J3 DB 25 EIA-422) 1 14 12 25 11 24 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 13 15 Reference Clock or 2 Ground AUX (J5) Pin 2 DB 9 AUX (J5) Pin 6 DB 9 Connect to SDM-2020 Modulator with EIA-422 DVB TX Interface Refer to Figure C-4. 1. Connect the “COMM” data interface connector (J1) to the DTE equipment. Note: Equivalent cable shall be computer grade, 100Ω, incorporating twisted and shielded pairs. Typical length shall be ≤ 16 feet (5 meters). 2. Connect the “A” data interface connector (J2) to the prime SDM-2020 Modulator “PARALLEL” (J4) connector and “AUX” (J5) connector using Cable (CA/6217) or equivalent. 3. Connect the “B” data interface connector (J3) to the backup SDM-2020 Modulator “PARALLEL” (J4) connector and “AUX” (J5) connector using Cable (CA/6217) or equivalent C–10 Rev. 3 SMS-301 Redundancy Switch SDM-2020 System Installation S D M -20 2 0 S AT E L L ITE M O D U L ATO R EIA -530 SE R IA L J4 PA R A LLEL J3 J3 J4 AUX J5 J5 S D M -20 2 0 S AT E L L ITE M O D U L ATO R EIA -530 PA R A LLEL J3 SE R IA L J4 AUX J5 CABLE (PL/6217) CABLE (PL/6217) J2 (A) J3 (B) SMS-301 1:1 REDUNDANCY SWITCH (S TA N D A R D C O N F IG U R AT IO N ) 1 00 M b it/s F o r P a ralle l D a ta Figure C-4. Connect to SDM-2020 Modulator with EIA-422 (DVB) TX Interface (100 Mbit/s Parallel Data) Rev. 3 C–11 SDM-2020 System Installation C.1.5 SMS-301 Redundancy Switch Connect to SDM-2020 Satellite Modulator I/O Connector, 25-Pin Interface Note: The section defines the requirements of the I/O 25-pin data interface for video and high-speed data applications used with the SDM-2020 Satellite Modulator. This interface uses serial format only. C.1.5.1 Description The SMS-301 data interface is a plug-in module that interfaces with the SDM-2020 Satellite Modulator. The interface used EIA-530 serial format Refer to Table C-6 for the cable pin assignments. Table C-6. Pin Assignments, 25-Pin SMS-301 DB25 Connector Pin # Name 24 TT-A 11 TT-B 2 SD-A 14 SD-B 1 SG 15 ST-A 12 ST-B 21 DF 25 MF C.1.5.2 SDM-2020 EIA-530 Serial (J4) DB 25 24 TT-A 11 TT-B 2 SD-A 14 SD-B 1 SG 15 ST-A 12 ST-B 21 DF 25 MF Connect to SDM-2020 Modulator with I/O Connector, 25-Pin Interface Refer to Figure C-5. 1. Connect the “COMM” data interface connector (J1) to the DTE equipment. Note: Equivalent cable shall be computer grade, 100Ω, incorporating twisted and shielded pairs. Typical length shall be ≤ 16 feet (5 meters). 2. Connect the “A” data interface connector (J2) to the prime SDM-2020 Modulator “SERIAL” (J4) connector using Cable (CA/3588) or equivalent. 3. Connect the “B” data interface connector (J3) to the backup SDM-2020 Modulator “SERIAL” (J4) connector using Cable (CA/3588) or equivalent C–12 Rev. 3 SMS-301 Redundancy Switch SDM-2020 System Installation S D M -2 02 0 S AT E L LIT E M O D U L ATO R EIA -530 SER IAL J4 PA R AL L EL J3 J3 J4 A UX J5 J5 S D M -2 02 0 S AT E L LIT E M O D U L ATO R EIA -530 PA R AL L EL J3 A UX J5 SER IAL J4 C A BLE (PL/3588) C A BLE (PL/3588) J2 (A ) J3 (B ) SMS-301 1:1 REDUNDANCY SWITCH (S TA N D A R D C O N FIG U R AT IO N ) Figure C-5. Connect to SDM-2020 Modulator with I/O Connector, 25-Pin Interface Rev. 3 C–13 SDM-2020 System Installation SMS-301 Redundancy Switch This page is intentionally left blank. C–14 Rev. 3 G Glossary The following is a list of acronyms and abbreviations that may be found in this manual: Acronym/ Abbreviation Ω @ A AC Al ASCII ASYNC AUX bit/s BW C CLK CLR cm COM COMM cr CS or CTS D&I dB D/C DC DD DF DAT Demod DEMUX DM DMDONL DTE Rev. 3 Definition Ohms at Ampere Alternating Current Alarm American Standard Code for Information Interchange Asynchronous Auxiliary bits per second Backward Alarm or Bandwidth Celsius Clock Clear Centimeters Common Communication Carriage Return Clear to Send Drop and Insert Decibels Down Converter Direct Current Day DEMOD Fault Data Bit Demodulator Demultiplexer Data Mode Demodulator On-Line Data Terminal Equipment g–1 Glossary SMS-301 Redundancy Switch DVB EFD EIA EXC EXT F FW GND Hz I/O IBS IDR IESS IF kbit/s LCD LED lf LVDS m M&C mA Max Mbit/s MC MF Mod MODONL MUX NC PL PWR RAM RD REF RF RMA RR RS RT RTS RX RXCLK RXD RZ s SCR SCT SCTE SD or SDA SG SLC SMS ST Sub g–2 Digital Video Broadcast EFData Compatible Electronic Industries Association External Clock External Reference Clock Fahrenheit Firmware Ground Hertz (cycle per second) Input/Output INTELSAT Business Services Intermediate Data Rate INTELSAT Earth Station Standards Intermediate Frequency Kilobits per second (103 bits per second) Liquid Crystal Display Light-Emitting Diode Line Feed Low Voltage Differential Signal mille (10-3) Monitor and Control Milliamperes Maximum Megabits per second Monitor and Control or Master Clock Modulator Fault Modulator Modulator On-Line Multiplexer No Connection or Normally Closed Parts List Power Random Access Memory Receive Data Reference Radio Frequency Return Material Authorization Receiver Ready Ready to Send, Recommended Standard, or Reed-Solomon Receive Timing Request to Send Receive (Receiver) Receive Clock Receive Data Return-to-Zero Second Serial Clock Receive Serial Clock Transmit Serial Clock Transmit External Send Data Signal Ground Serial Clock Satellite Multiservice System Send Timing Subminiature Rev. 3 SMS-301 Redundancy Switch SW SYNC TP TT TX TXCLK TXD TXO U/C US(A) V VAC VDC Ver W YY Rev. 3 Glossary Switch Synchronize Test Point Terminal Timing Transmit (Transmitter) Transmit Clock Transmit Data TX Octet Up converter United States (of America) Volts Volts, Alternating Current Volts, Direct Current Version Watt Year g–3 Glossary SMS-301 Redundancy Switch This page is intentionally left blank. g–4 Rev. 3 I AC Power (J11 and J12), 2–15 Board List, 2–15, 3-4 Command/Response, 1–4 Configuration Commands/Responses, 1–2, 1–7, 3-1, 3-2, 3-3, 3-5, 3-7, 3-10, 3-11, 3-12, 3-13, 3-15, 3-16, 3-28, A-2, A-3 Configuration Recall Menu, A-5, A-6 Configuration Save Menu, 3-16 Configuration Switch Control Menu, 3-15 Configuration System Menu, 3-10, 3-11 Connect SMS-301 Switch to SDM-2020 Modulator with I/O Connector, 25-Pin Interface, 2–21 Connect SMS-301 Switch to SDM-2020 Modulator with RS-422 DVB TX Interface, 2–19, 3-12, 3-13 Connect to SDM-2020 Modulator with LVDS Interface, 2–28 Connect to SDM-2020 Satellite Modulator I/O Connector, 25-Pin Interface, 2–23, 2–26 Connect to SDM-2020 Satellite Modulator with RS-422 (DVB) TX Interface (18 Mbit/s Serial Data), 2–20 Connection to SDM-2020 Satellite Modulator I/O Connector, 25-Pin Interface, 2–23, 2–26 Connection to SDM-2020 Satellite Modulator with Low Voltage Differential Signal Interface (Optional), 2–20 Connection to SDM-2020 Satellite Modulator with EIA-422 (DVB) TX Interface (100 Mbit/s Parallel Data), 2–21 Data I/O (J1, J2, J3), 37-Pin (PL/5952), 4-4 Data I/O Connector (J1, J2, J3) 37-Pin (PL/6201-2), 2–9 Data I/O Connector (J1, J2, J3), 25-Pin (PL/6026), 2–10, 4-3 Data I/O Connector (J1, J2, J3), 37-Pin (PL/5952), 2–8 Data I/O Connector (J1, J2, J3), 50-Pin (PL/5951), 2–7 DC Power (J11 and J12) (Optional), 2–6 Description (Standard Configuration), 2–15 Description (With RS-301 Option), 1–2 Device Address, 1–3 Rev. 3 Index EIA-422/-449, G.703, or V.35 (J1, J2, J3), 37-Pin (PL/5952), A-2, A-3 EIA-422/DVB TX (J1, J2, J3), 25-Pin (PL/6026), 4-3 EIA-422/EIA-449/V.35, A-2, A-3 End Character, 4-4 Equipment Inspection, A-4 External Connections, A-4 Fault Isolation, 2–3 Fault Summary Status Commands/Responses, 5-1, 5-4 Faults/Alarms, A-9 Faults3-5, 3-5, 3-7, 3-18, 3-19, 3-20, 3-21 Front Panel, 3-5, 3-7, 3-18, 3-19, 3-20, 3-21 Front Panel Keypad, 1–5, 1–6, 3-1, 3-6, 3-9 Front Panel Menus, 3-6 Ground, 3-9 IBS, IDR, ASYNC, or D&I (J1, J2, J3), 50-Pin (PL/5951), 2–4, 2–5, 2–6, 2–7, 2–8, 2–17, 2–23, 2–26, 4-5, 4-6, 4-7, 4-8, 4-11 IF Connections Transmit and Receive, 2–4, 2–5, 2–6, 2–8, 2–17, 4-3, 4-5, 4-6, 4-7, 4-8, 4-11 Installation Options, 2–17 Menu System, 4-3 Message Structure, 3-7 Modem Communications Configuration Commands/Responses, A-2 Monitor Menu, 1–2, 4-1 Operation Mode, 3-17 Prime Power, 3-2, 3-5, A-8, A-11 Remote Switch (RS-301) Option, 2–14 Remote Switch Control (J1) (RS-301 Option), 4-5 RX IF Connectors (J7, J8, J9), 2–5 Setup and Configuration, 2–13 SMS-301 Data Interface, 3-2 Specifications, 5-1 Start Character, 5-1 Status Commands/Responses, A-2 i–1 Index Status/Fault (J14), A-8 Stored Faults, 2–17 Stored Faults/Alarms, 2–17 Switch/Modem Communications Interface Connector (J13), 3-7, 3-20, 3-21 System Commands/Responses, 2–16 System Installation (Standard Configuration), A-7 i–2 SMS-301 Redundancy Switch Theory of Operation, 5-1, 5-3 Transmit IF Connectors (J4, J5, J6), 4-2 Unpacking, 2–13 Utility Modem Control, 2–1 Utility System, 3-3, 3-4, 3-5, 3-22, 3-23, 3-26, 3-27, 4-3, 4-4, 4-5 Rev. 3 METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281 0.01094 6.214 x 10-6 0.01 — — 1 inch 2.540 — 0.08333 0.2778 1.578 x 10-5 0.254 — 25.4 1 foot 30.480 12.0 — 0.3333 1.893 x 10-4 0.3048 — — 1 yard 91.44 36.0 3.0 — 5.679 x 10-4 0.9144 — — 1 meter 100.0 39.37 3.281 1.094 6.214 x 10-4 — — — 1 mile 1.609 x 105 6.336 x 104 5.280 x 103 1.760 x 103 — 1.609 x 103 1.609 — 1 mm — 0.03937 — — — — — — 1 kilometer — — — — 0.621 — — — Temperature Conversions ° Fahrenheit Unit 100 F = (C * 1.8) + 32 (water boils) 273.1 — -459.6° Fahrenheit C = (F - 32) * 0.555 (water freezes) — 212° Fahrenheit Formulas 0 — 32° Fahrenheit ° Centigrade (absolute 0) Units of Weight Gram Ounce Avoirdupois Ounce Troy Pound Avoir. Pound Troy Kilogram — 0.03527 0.03215 0.002205 0.002679 0.001 1 oz. avoir. 28.35 — 0.9115 0.0625 0.07595 0.02835 1 oz. troy 31.10 1.097 — 0.06857 0.08333 0.03110 1 lb. avoir. 453.6 16.0 14.58 — 1.215 0.4536 1 lb. Troy 373.2 13.17 12.0 0.8229 — 0.3732 1 kilogram 1.0 x 103 35.27 32.15 2.205 2.679 — Unit 1 gram 2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX ">
Download
Advertisement
Key features
Full automation
Redundancy for prime modem
Common interfaces for user data terminal equipment and uplink/downlink RF equipment
Integrated uplink 1:1 switch and downlink splitter
Monitor and Control (M&C) functions
Remote control via EIA-485 or EIA-232 interface
Configuration settings stored in non-volatile memory
Frequently asked questions
The SMS-301 Redundancy Switch provides redundancy for one prime modem using one identical backup modem. This ensures that data transmission can continue uninterrupted in case of a failure in the primary modem.
The SMS-301 supports common interfaces for user data terminal equipment and uplink/downlink RF equipment, as well as the primary and redundant (backup) modems. Some examples include EIA-485, EIA-232, and BNC connectors.
The SMS-301 can operate in both automatic and manual modes. In automatic mode, the switch will automatically detect a failure in the primary modem and switch to the backup modem. In manual mode, the user can manually switch between the modems.
The SMS-301 specifications can be found in Table 1-3 of the manual. This table includes information about the data interface switch, IF uplink switch, IF downlink splitter, local user interface, remote control, and other parameters.