ADASH DDS2000, DDS2007 Data Interface, A4300 VA3 Instrument User’s guide

Below you will find brief information for Data Interface DDS2000, Data Interface DDS2007, Instrument A4300 VA3. This document provides a user's guide for transferring and archiving data from the A4300-VA3 instrument to the DDS2000/DDS2007 data interface. It explains how to define sensor types, create routes, upload and download data, and work with the A4300 BDL application for remote data transfer.

PDF
Document
ADASH Data Interface DDS2000 & DDS2007 - User’s guide | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Transfer and archiving of data

  • Standard communication via RS232

  • Auto-detection instrument

  • Route administration and off-route measurement

  • Definition of wide range of sensor types

  • Cooperation with A4300 BDL application

Frequently asked questions

Connect the instrument via serial cable to a free serial port on your computer. Switch on the instrument and select Tools / Connect Instrument / A4300 item in the main menu. Then, push the Find button in the A4300 transfer window to establish a connection.

In the A4300 transfer window, open the data tree and drag and drop the desired measurement items into the A4300 window on the left. This will create a list of measurement points. Double-click or press Enter on each item to expand it and view sub-items. Click the Transfer to A4300 button. Create a new route in the instrument by clicking the New route button, enter the name, and click OK. The route is now downloaded to the instrument.

Connect the instrument via serial cable, select Tools / Connect Instrument / A4300, and push Find. Click the Transfer from A4300 button, select the route from the list in the instrument, and click OK to upload the route. Click the Store To Database button to save all measured data to relevant data cells.

There are two basic types: predefined STATIC VALUE (ISO, BEARING, L-BEARING, RPM, DC) with fixed measurement conditions, and definition free with measurement conditions enabled - STATIC VALUE (GENERAL, MANUAL), TIME, SPECTRA, ORDER ANALYSE.

You can define sensor types on three levels of the data tree: ROOT, MACHINE, and MEASUREMENT PLACE. Each sensor type has a defined group of units compatible with the instrument. You can select the unit within this group. The VA3 route sensor option allows using a sensor defined in the instrument, which can be useful for situations where the sensitivity is not the same.