4A6H7060A-SPEC-1


Add to my manuals
2 Pages

advertisement

4A6H7060A-SPEC-1 | Manualzz

TAG: _________________________________

NOTE: All dimensions are in mm/inches.

4A6H7060A-SPEC-1

SPECIFICATION

5 Ton Split System Heat Pump — 1 Ph

4A6H7060A

Product Specifications

OUTDOOR UNIT 12 4A6H7060A1000A

POWER CONNS. — V/PH/HZ 3

MIN. BRCH. CIR. AMPACITY

BR. CIR. PROT. RTG. – MAX. (AMPS)

COMPRESSOR

NO. USED - NO. STAGES

VOLTS/PH/HZ

R.L. AMPS 7 - L.R. AMPS

FACTORY INSTALLED

START COMPONENTS 8

INSULATION/SOUND BLANKET

COMPRESSOR HEAT

OUTDOOR FAN

DIA. (IN.) - NO. USED

TYPE DRIVE - NO. SPEEDS

CFM @ 0.0 IN. W.G. 4

NO. MOTORS - HP

MOTOR SPEED R.P.M.

VOLTS/PH/HZ

F.L. AMPS

OUTDOOR COIL — TYPE

ROWS - F.P.I.

FACE AREA (SQ. FT.)

TUBE SIZE (IN.)

REFRIGERANT CONTROL

REFRIGERANT

LBS. — R-410A (O.D. UNIT) 5

FACTORY SUPPLIED

LINE SIZE - IN. O.D. GAS 6

LINE SIZE - IN. O.D. LIQ. 6

CHARGING SPECIFICATION

SUBCOOLING

DIMENSIONS

CRATED (IN.)

WEIGHT

SHIPPING (LBS.)

NET (LBS.)

208/230/1/60

37

60

DURATION™ - SCROLL

1 - 2

208/230/1/60

28.8 - 152.9

NO

NO

YES

PROPELLER

27.6 - 1

DIRECT - 1

4760

1 - 1/4

825

208/230/1/60

1.30

SPINE FIN™

2 - 24

29.15

3/8

EEV

R-410A

13 LBS.- 3 OZ.

YES

1-1/8

3/8

10°F

H X W X D

51 X 35.1 X 38.7

330

293

MODELS

4A6H7060A

BASE

4

A

1147

(45-1/8)

B

946

(37-1/4)

C

870

(34-1/4)

D

1-1/8

E

3/8

From Dwg. D152862

F

152 (6)

G

98

(3-7/8)

H

219

(8-5/8)

J

86

(3-3/8)

K

508

(20)

1 Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on ARI standard 210/240. In order to achieve ARI standard rating, the indoor fan time delay on the comfort control must be enabled.

2 Rated in accordance with ARI standard 270.

3 Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses.

4 Standard Air — Dry Coil — Outdoor

5 This value approximate. For more precise value see unit nameplate.

6 Max. linear length 60 ft.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0* (* denotes latest revision).

7 This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current.

8 No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter.

Model

4A6H7060A1

A-Weighted Sound

Power Level [dB(A)]

74

63 Hz

58

Note: Rated in accordance with AHRI Standard 270-2008

Sound Power Level

Full Octave Sound Power [dB]

125 Hz

75

250 Hz

66

500 Hz

68

1000 Hz 2000 Hz 4000 Hz 8000 Hz

66 59 55 52

© 2013 American Standard Heating & Air Conditioning

Mechanical

Specification Options

General

The 4A6H7 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application.

Casing

Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Corrosion and weatherproof CMBP-G30 DuraBase™ base.

Refrigerant Controls

Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard.

Compressor

The Duration ® 2-stage compressor features internal over temperature and pressure protection and hermetic motor.

Other features include centrifugal oil pump and modular plugs for electrical connections.

Condenser Coil

The outdoor coil provides low airflow resistance and efficient heat transfer.

The coil is protected on all four sides by louvered panels.

Low Ambient Cooling

As manufactured, this unit has a cooling capability to 55°F. For low ambient cooling below 55° see Application Guide

APP-APG014-EN.

American Standard Heating & Air Conditioning www.americanstandardair.com

American Standard Heating & Air Conditioning has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.

05/13

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement