4A6H7060A-SPEC-1
SPECIFICATION
5 Ton Split System Heat Pump — 1 Ph
4A6H7060A
Product Specifications
OUTDOOR UNIT 12 4A6H7060A1000A
POWER CONNS. — V/PH/HZ 3
MIN. BRCH. CIR. AMPACITY
BR. CIR. PROT. RTG. – MAX. (AMPS)
COMPRESSOR
NO. USED - NO. STAGES
VOLTS/PH/HZ
R.L. AMPS 7 - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS 8
INSULATION/SOUND BLANKET
COMPRESSOR HEAT
OUTDOOR FAN
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS
CFM @ 0.0 IN. W.G. 4
NO. MOTORS - HP
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410A (O.D. UNIT) 5
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS 6
LINE SIZE - IN. O.D. LIQ. 6
CHARGING SPECIFICATION
SUBCOOLING
DIMENSIONS
CRATED (IN.)
WEIGHT
SHIPPING (LBS.)
NET (LBS.)
208/230/1/60
37
60
DURATION™ - SCROLL
1 - 2
208/230/1/60
28.8 - 152.9
NO
NO
YES
PROPELLER
27.6 - 1
DIRECT - 1
4760
1 - 1/4
825
208/230/1/60
1.30
SPINE FIN™
2 - 24
29.15
3/8
EEV
R-410A
13 LBS.- 3 OZ.
YES
1-1/8
3/8
10°F
H X W X D
51 X 35.1 X 38.7
330
293
MODELS
4A6H7060A
BASE
4
A
1147
(45-1/8)
B
946
(37-1/4)
C
870
(34-1/4)
D
1-1/8
E
3/8
From Dwg. D152862
F
152 (6)
G
98
(3-7/8)
H
219
(8-5/8)
J
86
(3-3/8)
K
508
(20)
1 Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program, which is based on ARI standard 210/240. In order to achieve ARI standard rating, the indoor fan time delay on the comfort control must be enabled.
2 Rated in accordance with ARI standard 270.
3 Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers or fuses.
4 Standard Air — Dry Coil — Outdoor
5 This value approximate. For more precise value see unit nameplate.
6 Max. linear length 60 ft.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft. For greater length consult refrigerant piping software Pub. No. 32-3312-0* (* denotes latest revision).
7 This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current.
8 No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter.
Model
4A6H7060A1
A-Weighted Sound
Power Level [dB(A)]
74
63 Hz
58
Note: Rated in accordance with AHRI Standard 270-2008
Sound Power Level
Full Octave Sound Power [dB]
125 Hz
75
250 Hz
66
500 Hz
68
1000 Hz 2000 Hz 4000 Hz 8000 Hz
66 59 55 52
© 2013 American Standard Heating & Air Conditioning
Mechanical
Specification Options
General
The 4A6H7 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are A.R.I. certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application.
Casing
Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Corrosion and weatherproof CMBP-G30 DuraBase™ base.
Refrigerant Controls
Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard.
Compressor
The Duration ® 2-stage compressor features internal over temperature and pressure protection and hermetic motor.
Other features include centrifugal oil pump and modular plugs for electrical connections.
Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer.
The coil is protected on all four sides by louvered panels.
Low Ambient Cooling
As manufactured, this unit has a cooling capability to 55°F. For low ambient cooling below 55° see Application Guide