Extron SMX System MultiMatrix Switcher Matrix Switcher User Guide
Below you will find brief information for Matrix Switcher SMX System MultiMatrix Switcher. The SMX is a modular, configurable, multi-format card cage system, available in 2U, 3U, 4U, or 5U frames. Each frame has rear panel slots into which I/O boards can be inserted in any configuration and signal type. The SMX can switch audio and video signals for a variety of applications. This device supports multiple input formats, including DVI, HDMI®, HD-SDI, VGA, S-video, composite video, and audio. The SMX uses a hot swappable input/output board for simple installation and maintenance.
Advertisement
Advertisement
SMX System
MultiMatrix Switcher
User Guide
Matrix Switcher
68-1452-01 Rev. C
04 13
Safety Instructions • English
WARNING: This symbol, , when used on the product, is intended to alert the user of the presence of uninsulated dangerous voltage within the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol, , when used on the product, is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron website, www.extron.com
.
Instructions de sécurité • Français
AVERTISSEMENT: Ce pictogramme, , lorsqu’il est utilisé sur le produit, signale à l’utilisateur la présence à l’intérieur du boîtier du produit d’une tension électrique dangereuse susceptible de provoquer un choc électrique.
ATTENTION: Ce pictogramme, , lorsqu’il est utilisé sur le produit, signale à l’utilisateur des instructions d’utilisation ou de maintenance importantes qui se trouvent dans la documentation fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets connexes, lisez les informations de sécurité et de conformité Extron, réf. 68-
290-01, sur le site Extron, www.extron.fr
.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol auf dem Produkt soll den Benutzer darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind und die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol auf dem Produkt soll dem Benutzer in der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie in den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer 68-
290-01) auf der Extron-Website, www.extron.de
.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo, , cuando se utiliza en el producto, avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo, , cuando se utiliza en el producto, avisa al usuario de la presencia de importantes instrucciones de uso y mantenimiento recogidas en la documentación proporcionada con el equipo.
Para obtener información sobre directrices de seguridad, cumplimiento de normativas, compatibilidad electromagnética, accesibilidad y temas relacionados, consulte la Guía de cumplimiento de normativas y seguridad de Extron, referencia 68-290-01, en el sitio Web de Extron, www.extron.es
.
Chinese Simplified
(简体中文)
警告: 产品上的这个标志意在警告用户该产品机壳内有暴露的危险
电压,有触电危险。
注 意 :
产 品 上 的 这 个 标 志 意 在 提 示 用 户 设 备 随 附 的 用 户 手 册 中 有
重要的操作和维护(维修)说明。
关于我们产品的安全指南、遵循的规范、 EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 www.extron.cn
,参见 Extro n
安全规范指南,产品编号 68-290-01 。
Chinese Traditional
(繁體中文)
警告: 若產品上使用此符號,是為了提醒使用者,產品機殼內存在著
可能會導致觸電之風險的未絕緣危險電壓。
注意
若產品上使用此符號,是為了提醒使用者。
有關安全性指導方針、法規遵守、EMI/EMF 相容性、存取範圍和相關主題的詳細
資訊,請瀏覽 Extron 網站: www.extron.cn
,然後參閱《Extron 安全性與法規
遵守手冊》,準則編號 68-290-01。
Japanese
警告: この記号 が製品上に表示されている場合は、筐体内に絶縁されて
いない高電圧が流れ、感電の危険があることを示しています。
注意: この記号 が製品上に表示されている場合は、本機の取扱説明書に
記載されている重要な操作と保守(整備)の指示についてユーザーの
注意を喚起するものです。
安全上のご注意、法規厳守、EMI/EMF適合性、その他の関連項目に
ついては、エクストロンのウェブサイト www.extron.jp
より
『
Extron Safety and Regulatory Compliance Guide
』
(P/N 68-290-01)
をご覧ください。
Korean
경고: 이 기호 , 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 , 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
안전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련
항목에 대한 자세한 내용은 Extron 웹 사이트( www.extron.com
)의
Extron 안전 및 규제 준수 안내서, 68-290-01 조항을 참조하십시오.
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference; the user must correct the interference at his own expense.
NOTE: This unit was tested with shielded I/O cables on the peripheral devices. Shielded cables must be used to ensure compliance with FCC emissions limits.
For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the “ Extron Safety and
Regulatory Compliance Guide ” on the Extron website.
Copyright
© 2013 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks (R) , registered service marks (SM) , and trademarks (TM) are the property of
RGB Systems, Inc. or Extron Electronics:
AVTrac, Cable Cubby, CrossPoint, eBUS, EDID Manager, EDID Minder, Extron, Flat Field,GlobalViewer, Hideaway, Inline, IP Intercom, IP Link, Key Minder, LockIt, MediaLink, PoleVault,
PowerCage, PURE3, Quantum, SoundField, System Integrator, TouchLink, V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall
Registered Service Mark (SM) : S3 Service Support Solutions
Registered Trademarks (®)
Trademarks ( ™ )
AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), AIS (Advanced Instruction Set), Auto-Image, CDRS (Class D Ripple Suppression), DDSP (Digital Display
Sync Processing), DMI (Dynamic Motion Interpolation), Driver Configurator, DSP Configurator, DSVP (Digital Sync Validation Processing), FastBite, FOXBOX, IP Intercom HelpDesk, MAAP,
MicroDigital, ProDSP, QS-FPC (QuickSwitch Front Panel Controller), Scope-Trigger, SIS, Simple Instruction Set, Skew-Free, SpeedMount, SpeedNav, SpeedSwitch, Triple-Action Switching,
XTP, XTP Systems, XTRA, ZipCaddy, ZipClip
Conventions Used in this Guide
Notifications
The following notifications are used in this guide:
CAUTION: A caution indicates a situation that may result in minor injury.
ATTENTION: Attention indicates a situation that may damage or destroy the product or associated equipment.
NOTE: A note draws attention to important information.
TIP: A tip provides a suggestion to make working with the application easier.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
E X! *X1&* X2)* X2#* X2! CE
}
NOTE: For commands and examples of computer or device responses mentioned in this guide, the character “0” is used for the number zero and “ O ” represents the capital letter “ o .”
Computer responses and directory paths that do not have variables are written in the font shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here: ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are written in the font shown here:
From the File menu, select New .
Click the OK button.
Specifications Availability
Product specification are available on the Extron website, www.extron.com
.
Contents
Introduction
................................................... 1
SMX Series Description ...................................... 1
Definitions ........................................................... 3
Features ............................................................. 4
Installation and Cabling
............................... 6
UL Safety Requirements ..................................... 6
Rear Panel Features and Connections ................ 7
Power and Control Connections ..................... 7
Input and Output Boards ................................ 8
Other I/O Boards .......................................... 10
SMX Frame and I/O Board Installation .............. 10
Installing the I/O Boards ................................ 10
Wiring the Audio Connectors ............................ 12
Operation
..................................................... 13
Front Panel Overview ........................................ 13
I/O Plane Selection Buttons .......................... 14
Input and Output Buttons ............................. 14
Control Buttons ............................................ 15
Power Indicator LEDs ................................... 15
Front Panel Configuration Port ...................... 16
Powering Up .................................................... 16
Front Panel Operation ....................................... 16
Ties — General Information .......................... 16
Creating Ties ................................................ 17
Viewing Ties ................................................. 18
Removing Ties .............................................. 19
Replacing Ties .............................................. 20
Muting or Unmuting a Video, Audio, or Video and Audio Output .......................... 20
Saving and Recalling I/O Presets .................. 22
Setting RGB Delay (VGA and RGBHV
Boards Only) ................................................ 24
(Executive Modes) ....................................... 25
Setting Background Illuminations .................. 26
Configuring Via the Rear Panel
RS232/RS422 Port ......................................... 27
Using the Front Panel ................................... 27
Viewing and Adjusting the Audio Input Level ..... 27
Using the Front Panel ................................... 27
Viewing and Adjusting the Audio Output
Volume ............................................................ 29
Using the Front Panel ................................... 29
Using Reset Levels ........................................... 31
Using the Front Panel ................................... 31
Using the Rear Panel .................................... 31
Troubleshooting ................................................ 33
SIS Configuration and Control
RS-232 or RS-422 Link .................................... 34
Ethernet (LAN) Port........................................... 34
Ethernet Cable .............................................. 34
Default IP Addresses .................................... 34
Establishing an Ethernet Connection............. 35
Connection Timeouts ................................... 35
Number of Connections ................................ 35
Using Verbose Mode .................................... 35
SIS Programming Guide ................................... 36
Communications ......................................... 36
Switcher-Initiated Messages ......................... 36
Switcher Error Responses ............................ 37
Using the Command and Response Table for SIS Commands .......................................... 37
Symbol Definitions ........................................ 38
Command and Response Table for SIS Commands ...................................... 42
Using the Command/Response Table for IP SIS Commands ...................................... 53
Symbol Definitions ........................................ 53
Command and Response Table for IP SIS Commands .................................. 56
SMX System MultiMatrix Switcher • Contents iv
SMX Control Software
................................ 59
Installing and Starting the SMX Control
Program .......................................................... 59
Installing the Program ................................... 59
Starting the Program .................................... 60
Using Emulation Mode...................................... 61
Using the Program............................................ 62
Control Program Menus and Pages .............. 63
Customizing the SMX Window ...................... 75
Managing Ties .............................................. 76
IP Settings/Options ....................................... 77
HTML Configuration and Control
Accessing the Web Pages ................................ 87
System Status Pages ....................................... 89
System Status .............................................. 89
Physical Configuration .................................. 90
DSVP ........................................................... 90
Configuration Pages ......................................... 91
System Settings Page .................................. 91
Passwords Page........................................... 94
Email Settings Page ...................................... 94
Firmware Upgrade Page ............................... 96
File Management Page ..................................... 97
Uploading Files ............................................. 98
Adding a Directory ........................................ 98
Other File Management Activities .................. 98
Control Pages................................................... 98
User Control Page ........................................ 98
Presets Page .............................................. 104
Ethernet Control
....................................... 106
Ethernet Link .................................................. 106
Ethernet Connection ................................... 106
Default Address .......................................... 106
Configuring the SMX for Network
Communication ......................................... 107
Configuring the SMX for Network Use
Via the ARP Command .............................. 108
Connect as a Telnet Client .......................... 109
Subnetting — A Primer ................................... 111
Gateways ................................................... 111
Local and Remote Devices ......................... 111
IP Addresses and Octets ............................ 111
Subnet Masks and Octets .......................... 112
Determining Whether Devices Are on the Same Subnet .................................. 112
Reference Information
............................. 113
Mounting the Switcher .................................... 113
Tabletop Placement .................................... 113
UL Guidelines for Rack Mounted Devices ... 113
Rack Mounting ........................................... 114
Button Labels ................................................. 114
Using the Button Label Generator ............... 114
Replacing Button Labels ............................. 116
Button Label Blanks ....................................... 117
SMX System MultiMatrix Switcher • Contents v
Introduction
This guide contains installation, configuration, and operating information for the Extron
SMX MultiMatrix Switcher with optional input and output (I/O) boards. It covers operations using the front panel controls and Simple Instruction Set (SIS ™ ) commands. It also describes how to load and start up the SMX Control Program that runs on Windows ® operating systems and how to connect to the built-in HTML pages for additional methods of operating the SMX.
In this guide, the terms “SMX switcher,” “SMX,” and “switcher,” are used interchangeably to refer to a typical SMX System MultiMatrix Switcher. “Video model” refers to any SMX switcher that switches only video. “Audio model” refers to any SMX switcher that switches only audio.
This section contains general information about the SMX switcher and includes:
• SMX Series Description
•
•
SMX Series Description
The SMX is a modular, configurable, multi-format card cage system, available in
2U (SMX 200), 3U (SMX 300), 4U (SMX 400), or 5U (SMX 500) frames. Each frame has rear panel slots into which I/O boards can be inserted in any configuration and signal type.
POWER
12V
0.3A MAX
MODE
FOX HDSDI
OPTICAL
1 2
HD/SDI IN
1 2
BUFFERED OUTPUTS
Tx Rx
Extron FOX HD-SDI
Transceiver Digital Monitors
HDTV Monitors
HD-SDI
Camera
DVI Equipped PCs
POWER
12V MODE
FOX HDSDI
OPTICAL
1 2
HD/SDI IN
1
BUFFERED OUTPUTS
2
Tx Rx
Extron FOX HD-SDI
Transceiver
HD Camera Compact HDTV
Camera Systems
PCs
DVD/VCR Combo
DVD Player
REMOTE
RS232/RS422
®
US
LISTED
I.T.E.
1 2
INPUTS
3 4
PLANE ADRESS
1
1
5
2
2
3 4
SDI / HDSDI INPUTS
5
COMPUTER IN
3
6 7
6
4
8
7 8
PLANE ADRESS
DIGITAL VIDEO
PLANE ADRESS
PLANE ADRESS
1
1
2
2
3
3
4
S-VIDEO IN
5
4
S-VIDEO IN
1
6
2
7
3
1
L
1
R L 2 R
2
L 3 R
3 4
VIDEO INPUTS
5
L
4
R L
5
R L
6
R
6 7
L
7
R L 8 R
8
4
Y
C
PLANE ADRESS
S-VIDEO
Y
C
PLANE ADRESS
WB VIDEO
8
PLANE ADRESS
PLANE ADRESS
OUT
1
1
IN OUT
2 3
2
OUTPUTS
IN OUT
FIBER OPTIC
3
IN OUT
1
SDI / HDSDI OUTPUTS
COMPUTER OUT
2 3
6 6
4
4
4
IN
5 6 7 8
1
1
2
2 3 4
S-VIDEO OUT
5
3 4
6 7
S-VIDEO OUT
L
1
R L
2
R L
3
R
VIDEO OUTPUTS
L
4
R L
5
R L
6
R
6
6
L
7
R L
8
R
8
Extron
SMX System
MultiMatrix Switcher
Sound Systems
FREEZE
1
FREEZE
1
2
2
3
PROGRAM
4 5
3
PREVIEW
4 5 6
6
LOGO 1
/BLACK
LOGO 2
/BLACK
TRANSITION
CUT TAKE
EFFECTS
WIPE PIP
DISSOLVE TITLE
SIZE
BRIGHT
/CONT
DETAIL
CENTER
COLOR
/TINT
ZOOM
CONFIG
Extron
ISS 506
MENU NEXT
ADJUST VOLUME
ADJUST
ISS 506
Integration Seamless Switcher
Main Projection
Display
Figure 1. Typical Matrix Swticher Application (5U Unit)
Data Monitors
Video Recorders
Video Monitors
Video Monitors
SMX System MultiMatrix Switcher • Introduction 1
Board Type
Composite
Video
S-video
SDI and
HD-SDI
Ultra
Wideband
Sync
I/O Connector
BNC
BNC
BNC
BNC
BNC
The table below gives a list of available I/O boards, the number and type of connectors, and the number of slots used by any given board. For example, from the first row, the SMX 84 V is an 8x4 (8 inputs by 4 outputs) composite video board. It takes up one slot, and has BNC connectors.
SMX 44 HD-SDI
4x4 (1)
Board Names
Board Sizes (Slots Used)
SMX 84 V
8x4 (1)
SMX 84 YC
8x4 (2)
SMX 84 HD-SDI
8x4 (1)
SMX 84 WB
8x4 (1)
SMX 88 V
8x8 (1)
SMX 88 YC
8x8 (2)
SMX 88 HD-SDI
8x8 (1)
SMX 88 WB
8x8 (1)
SMX 88
SYNC (H or V)
8x8 (1)
SMX 1616 V
16x16 (2)
SMX 1616 YC
16x16 (4)
SMX 1616 HD-SDI
16x16 (2)
SMX 1616 WB
16x16 (2)
SMX 1616
SYNC (H or V)
16x16 (2)
Stereo Audio
DVI
DVI-Pro
S-video
Boards
HDMI
Wideband
VGA
Fiber Optic
(singlemode)
Fiber Optic
(multimode)
Captive screw
DVI-I
(digital) mini DIN
HDMI
15-pin HD
Optical
(SFP)
L R
SMX 44 DVI
4x4 (1)
SMX 44
DVI Pro
4x4 (1)
SMX 44 HDMI
4x4 (1)
SMX 48 DVI
4x8 (2)
SMX 48
DVI Pro
4x8 (2)
SMX 48 HDMI
4x8 (2)
SMX 84 A
8x4 (1)
SMX 84 DVI
8x4 (2)
SMX 84
DVI Pro
8x4 (2)
SMX 84 SV
8x4 (1)
SMX 84 HDMI
8x4 (2)
SMX 84 VGA
8x4 (2)
SMX 88 H+V
8x8 (2)
SMX 88 A
8x8 (1)
SMX 88 DVI
8x8 (2)
SMX 88
DVI Pro
8x8 (2)
SMX 88 SV
8x8 (1)
SMX 88 HDMI
8x8 (2)
SMX 88 VGA
8x8 (2)
SMX 88
FOX 4G SM
8x8 (1)
SMX 88
FOX 4G MM
8x8 (1)
SMX 1616 A
16x16 (2)
SMX 1616 SV
16x16 (2)
SMX 1616 VGA
16x16 (4)
SMX 1616
4G SM
16x16 (2)
SMX 1616
4G MM
16x16 (2)
USB B input
SMX 44 USB
4x4 (1)
SMX 84 USB
8x4 (1)
USB
USB A output
The 2U frame has 4 single board slots, the 3U frame has 6 board slots, the 4U frame has
8 slots, and the 5U frame has 10 slots. Each slot supports power and control connections to the I/O boards. When a board is installed into a slot it may use more than one slot. For example, the SMX 1616 VGA board uses four slots. The slots that a board covers are not available for other I/O board installation until that multi-slot board has been removed (see
on page 10 for details).
NOTE: To customize the SMX unit, use the SMX Configurator program, available at www.extron.com
, or contact Extron Customer Support (see back cover for contact
numbers).
SMX System MultiMatrix Switcher • Introduction 2
Definitions
The following terms are used throughout this guide:
Tie — An input-to-output connection
Set of ties — An input tied to two or more outputs. An output can never be tied to more than one input
Configuration — One or more ties or one or more sets of ties
Current configuration — The configuration that is currently active in the switcher (also called configuration 0)
Plane — A board or set of boards that will be switched together. Plane numbers are set by a rotary switch on each board.
Global memory preset — An I/O configuration that has been stored (all planes). Up to 32
global memory presets can be stored. Preset locations are assigned to the input buttons and output buttons and can be selected from the front panel, serial port, or Ethernet control for either saving or retrieving. When a preset is recalled from memory, it becomes the
current configuration.
Plane memory preset — A plane configuration that has been stored. Up to 10 plane
presets per switching plane can be saved and recalled without affecting the other I/O plane connections.
EDID — Extended Display Identification Data. A communications protocol or instruction set developed by VESA (Video Electronics Standards Association) for the identification of display devices to computers using the DDC (Display Data Channel) transmission standard
HDCP — High-bandwidth Digital Content Protection. An encryption method developed by Intel ® that protects copyrighted digital entertainment material that uses the Digital Video
Interface (DVI) and High Definition Multimedia Interface (HDMI)
DVI — Digital Visual Interface. The digital video connectivity standard developed by DDWG
(Digital Display Work Group). This connection standard offers two different connectors: one with 24 pins that handles digital video signals only, and one with 29 pins that handles both digital and analog video. DVI standard uses TDMS (Transition Minimized Differential
Signal) from Silicon Image and DDC (Display Data Channel) from VESA (Video Electronics
Standards Association). DVI-D supports digital signal transfer only, and DVI-I supports both digital and analog signal transfer.
HDMI ® — High Definition Multimedia Interface. A specification developed by the HDMI
Working Group that combines video, multi-channel audio, and control signals into a single digital interface for use with DVD players, digital television, and other audiovisual devices
SDI — Serial Digital Interface. This standard is based on a 270 Mbps transfer rate. It is a
10-bit, scrambled, polarity independent interface with common scrambling for both component ITU-R 601 and composite digital video and four channels of embedded digital audio.
HD-SDI — High-definition version of SDI specified in SMPTE-292M. This standard transmits audio and video over a single coaxial cable with a data rate of 1.485 Gbit/second.
USB — Universal Serial Bus. Developed by PC and telecom industry leaders, USB was designed for easy plug-and-play expansion outside the device, requiring no additional circuit cards. USB devices can be attached or detached without removing computer power.
SMX System MultiMatrix Switcher • Introduction 3
Features
Hot swappable input/output boards and SFP modules — Any board or SFP module can be added or replaced without taking the unit out of service or removing the power.
Channel to channel isolation — Each I/O board provides isolation between channels and extremely low electrostatic emissions.
Quick-Switch Front Panel Controller (QS-FPC ™ ) — The QuickSwitch FPC allows for touch-of-a-button input and output selection and switching.
Presets — This time-saving feature allows the setup and recall of recurring I/O configurations using either the front panel, RS-232 or RS-422, or Ethernet.
Global: Up to 32 individual I/O configurations may be saved and recalled.
Plane: Up to 10 presets per switching plane can be saved and recalled without affecting the other I/O plane connections.
RS-232 and RS-422 control — A rear panel RS-232/RS-422 control port provides connection to control software via a control system or PC.
Front panel control configuration port — A front panel 2.5 mm mini jack is available for setup and configuration the SMX without having to access the rear of the unit while it is installed within a rack system.
Simple Instruction Set (SIS) — The remote control protocol uses SIS commands for easy programming and operation.
Control and configuration software — For RS-232, RS-422, and Ethernet control from a PC, the Extron control software that runs on Windows operation systems is supplied with every matrix switcher. This icon-driven software uses a graphical, drag-and-drop interface to make input and output configuration and other customization functions simple and convenient. The software also offers an emulation mode for configuration of an off-site matrix switcher; the input and output configuration can then be saved for future downloading to the SMX.
IP control (Ethernet) via the LAN port — This port allows the switcher to be controlled through an Ethernet local area network (LAN) or wide area network (WAN) using standard IP internet protocols. This ability provides flexible connectivity for off-site control and password-protection of the switcher.
Web hosting — Users can upload customized web pages into the switcher.
Digital Sync Validation Processing (DSVP ™ ) — In critical environments or unmanned, remote locations, it may be vital to know that sources are active and switching. Extron
DSVP confirms that input sources are active by scanning all sync inputs for active signals.
DSVP provides instant frequency feedback for composite sync or separate horizontal and vertical sync signals via the RS232/RS422 port or the Ethernet port.
Virtual plane grouping — Switching planes can be grouped together to make a single, virtual switching plane. Plane grouping allows several signal planes to act as a single unit with a single control command affecting all planes
Audio input gain and attenuation — Users can set the input level of audio gain or attenuation (-18 dB to +24 dB) via the RS232/RS422 port, an Ethernet link, or the front panel. Individual input audio levels can be adjusted so there are no noticeable volume differences between sources.
Audio output volume (audio I/O boards) — The audio volume of each output can be displayed and adjusted through a range from full output to completely silent using the front panel, or through serial port or Ethernet control.
RGB delay (VGA and RGBHV) — This allows the delay of the output of the signal by a specified time (the delay time), enabling video and audio signals to be kept in sync. RGB delay can be set via the front panel, RS-232 or RS-422, or LAN connection.
SMX System MultiMatrix Switcher • Introduction 4
Three front panel security lockout modes (executive modes) — If a matrix switcher is installed in an area where operation by unauthorized personnel may be a problem, either of two security lockout modes can be implemented (the third mode is unlocked). When a front panel locked mode is enabled, a special button combination or SIS command is required to unlock the front panel controller and make the front panel operational.
Upgradeable firmware — The firmware that controls all switcher operation can be upgraded on location through the serial port or the Ethernet port, without taking the switcher out of service. Firmware upgrades are available for download on the Extron website, www.extron.com
, and they can be installed using the Windows-based control program or the built-in HTML pages.
Button labeling — The Extron button label software lets you create labels to place in the front panel I/O buttons, with names, alphanumeric characters, or color bitmaps.
Alternatively, labels can be made with any Brother ® P-Touch ® or comparable labeler.
Operational flexibility — Operations such as input and output selection, setting of presets, and adjustment of audio levels can be performed on the front panel or via the
Ethernet or serial link. The serial links allow remote control via a PC or control system. The
Ethernet link allows multiple remote links with two levels of password-protection.
• Front panel controls — The front panel controls support input and output selection and grouping, preset creation and selection, RGB delay, audio gain and attenuation, and volume control (audio models).
• Windows-based control program — Via serial port or Ethernet remote control, the
Windows-based control software provides a graphical interface and drag-and-drop or point-and-click operation.
• Simple Instruction Set (SIS) — SIS commands provides easy programming and operation.
Switching flexibility — The SMX provides individually buffered, independent matrix switched outputs with audio follow and audio breakaway for audio models:
• Tie any input to any or all outputs
• Quick multiple tie — Multiple inputs can be switched to multiple outputs simultaneously. This allows all displays (outputs) to change from source to source at the same time.
• Audio follow — Audio can be switched with its corresponding video input via front panel control, under Ethernet, RS-232 or RS-422 control, or by giving the video and audio boards the same plane address.
• Audio breakaway — Audio can be broken away from its corresponding video signal.
This feature allows any audio signal to be selected with any video signal simultaneously to one or all outputs in any combination. Audio breakaway switching can be done via
Ethernet, RS-232 or RS-422 control, or by giving the video and audio boards different plane addresses.
SMX System MultiMatrix Switcher • Introduction 5
Installation and
Cabling
This section describes how to install the I/O boards and connect cables to the SMX device.
Topics in this section include:
•
•
Rear Panel Features and Connections
•
SMX Frame and I/O Board Installation
•
UL Safety Requirements
The requirements listed below pertain to the safe installation and operation of this SMX.
Important safety instructions:
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produces heat.
9. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third plug are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
SMX System MultiMatrix Switcher • Installation and Cabling 6
Rear Panel Features and Connections
4
3
2
1
REMOTE
RS232/RS422
OUT
1
IN
1
1
1
1
1
5
2
2
2
2 3
OUT
2
DVI-D INPUTS
IN
OUT
3
IN
FIBER OPTIC
6 7
4
OUT
4
IN
8
1
ADDRESS
OUT
5
IN
ADDRESS
DIGITAL VIDEO
ADDRESS
1
1
2
3
4
SDI / HDSDI INPUTS
5
COMPUTER IN
3
6 7
4
8
3
4
S-VIDEO IN
5
6 7
8
ADDRESS
S-VIDEO
ADDRESS
S-VIDEO
1
3 4 1 2 3 4 1
S-VIDEO IN
2
2
S-VIDEO OUT
3
1 2
L 1 R L
2
R
3
L 3 R L
4
VIDEO INPUTS
4
INPUTS
R L
5
5 R
6
L
6
R
7 8
L
7
R L
8
R
ADDRESS
VIDEO
ADDRESS
2
2
1
5
2 3
OUT
6
DVI-D OUTPUTS
IN
OUT
7
IN
FIBER OPTIC
3
3
4
4
5
5
SDI / HDSDI OUTPUTS
COMPUTER OUT
2 3
6
6
6 7
3
4
S-VIDEO OUT
5
4
6
4
OUT
8
IN
7
7
7
4
8
L
1
R
1
L
2
VIDEO OUTPUTS
3
2 R
L
3
R
4
L 4
OUTPUTS
R
L
5
R
L 6 R
L
7
R
L 8 R
8
ADDRESS
100-240V , 50-60Hz
2.0A MAX.
13
Figure 2. SMX Rear Panel Features a AC power connector b LAN Ethernet port c Reset button and LED d Remote serial port e to l I/O boards (optional) m Plane address switch
Power and Control Connections
a AC power connector — Plug a standard IEC power cord from a 100 to
240 VAC, 50 Hz or 60 Hz power source into this receptacle.
100-240V , 50-60Hz
2.0A MAX.
b LAN Ethernet port — Connect the switcher to an Ethernet LAN or
WAN via this RJ-45 connector. Ethernet connection allows the operator to control the switcher from a remote location. When connected to an
Ethernet LAN or WAN, the switcher can be accessed and operated from a computer running a standard Internet browser.
Ethernet connection indicators — The LEDs marked “Link” and “Act” indicate the status of the Ethernet connection. The green Link LED lights when the SMX is connected to an Ethernet LAN, and the amber Act LED flickers, indicating data transmission as the devices communicate.
NOTE: Do not use standard telephone cables, as they do not support Ethernet or fast
Ethernet. Do not stretch or bend cables. Transmission errors can occur.
Choosing a network cable
Ethernet links use Category (CAT) 3, 4, 5, 5e, 6, or CAT 7 unshielded twisted pair (UTP) or shielded twisted pair (STP) cables, terminated with RJ-45 connectors. Ethernet cables are limited to 328 feet (100 m).
The cable used depends on the network speed. The SMX supports both 10 Mbps
(10Base-T — Ethernet) and 100 Mbps (100Base-T — fast Ethernet), half-duplex and full-duplex, Ethernet connections.
• 10Base-T Ethernet requires, at a minimum, CAT 3 UTP or STP cable.
• 100Base-T fast Ethernet requires, at minimum, CAT 5 UTP or STP cable.
SMX System MultiMatrix Switcher • Installation and Cabling 7
8
9
5
6
7
10
11
12
Reset button and Ethernet cable termination
It is essential that the Ethernet cables used be the correct type of cable and terminated with the correct pinout. The cable can be terminated as either a patch cable or a crossover cable
and must be properly terminated relevant to the application (see Ethernet Control on
page 106 for termination details).
c Reset button (recessed) — Press and hold in this recessed button to reset the
SMX to the default (factory setting) mode. The lit (green) LED blinks once.
d Remote port — Connect a host device, such as a PC or touchpanel control, to the
SMX via this 9-pin D connector for serial RS-232 or RS-422 control.
7
8
9
5
6
1
2
3
4
7
8
5
6
9
3
4
1
2
—
—
TX
Tx
—
Rx
—
Transmit data
Receive data
Gnd
Signal ground
—
—
—
—
—
—
—
Not used
Not used
Not used
Not used
— Not used
—
—
TX
Tx
Rx
—
Gnd
Transmit data (-)
Receive data (-)
Not used
Signal ground
—
RX+
TX+
—
Tx+
—
Figure 3. Remote Port Pin Assignments
Not used
5
1
9 6
Female
5
6
Male
9
1
NOTES:
•
See SIS Configuration and Control
on page 34 for SIS command definitions
on page 59 control software details.
• The SMX can support either RS-232 or RS-422 serial communication protocol, and can operate at 9600, 19200, 38400, or 115200 baud rates
(see Operation on page 13 to configure the RS-232/RS-422 port).
Input and Output Boards
The I/O boards on any unit may vary with each installation, depending on desired configuration and use. All board types have the input and the output connectors clearly
marked, and each board has a 16-position rotary switcher (see m, figure 2 ) for setting the
I/O plane address. An LED on the board indicates when power is present.
NOTE: Boards with the same plane address switch simultaneously.
Figure 2 shows some, but not all, board variations that can be installed into an SMX frame.
Boards have different combinations of input and output connectors, depending on the
specific board installed. To install any board into an SMX frame slot (see SMX Frame and
I/O Board Installation on page 10).
NOTE: Control signal ground pins may be labeled as or “G”. Audio ground pins may be labeled as or . The wiring and function are the same, whichever way your product is labeled.
e SMX 44 DVI — Connect DVI single link high resolution digital input devices (up to
1600x1200 @ 60 Hz) or HDTV devices up to 1080p, to any of the DVI-I female input connectors. Connect suitable digital displays to the DVI-I female output connectors.
2 3 2 1 4 1 3 4
DVI-D INPUTS ADDRESS DVI-D OUTPUTS
SMX System MultiMatrix Switcher • Installation and Cabling 8
f SMX 44 FOX 4G MM — Connect fiber optic input cables from a signal source to input ports and from output ports to a suitable display. LEDs light when signals are present.
1 2 3 4 5 6 7 8
OUT IN OUT IN OUT IN OUT IN OUT
IN
OUT
IN
OUT IN OUT IN
FIBER OPTIC ADDRESS FIBER OPTIC g SMX 88 HD-SDI — Connect SDI, HD-SDI, or dual link HD-SDI input sources to any of the BNC input connectors. Connect suitable display devices to the BNC output connectors.
DIGITAL VIDEO
1 2 3 4
SDI / HDSDI INPUTS
5 6 7 8 1 1 2 2 3 3 4 5
SDI / HDSDI OUTPUTS
6 6 7 7
ADDRESS
NOTE: It is recommended to terminate unused I/Os with 75 ohm terminating connectors.
h SMX 88 VGA — Connect high resolution computer-video rate input sources to any of the 15-pin HD female connectors. Connect suitable display devices to the 15-pin HD output connectors.
COMPUTER IN COMPUTER OUT
1 2 3 4 1 2 3 4
5 6 7 8
ADDRESS
5 6 7 8 i SMX 88 SV (DIN) and j SMX 84 YC — Connect S-video input sources to any of the BNC pairs or 4-pin mini DIN input connectors. Connect suitable display devices to the BNC pairs or 4-pin mini DIN output connectors.
S-VIDEO
1 2 3 4
S-VIDEO IN
5 6 7 8
ADDRESS
S-VIDEO
1 2 3 4
S-VIDEO OUT
5 6 7 8 i j
1 2 3 4 1 2 3 4 1 2 3 4
ADDRESS
S-VIDEO IN S-VIDEO OUT k SMX 84 V — Connect composite video input signals to the BNC input connectors.
Connect display devices to the BNC output connectors.
VIDEO
8 1 2 3 4
VIDEO INPUTS
5 6 7
ADDRESS
1 2
VIDEO OUTPUTS
3 4 l SMX 88 A — Connect stereo or mono audio input signals to any of the eight sets of
3.5 mm, 5-pole captive screw connectors marked Inputs. Wire the connector for the appropriate signal type (see
Wiring the Audio Connectors on page 12).
L
1
R L
3
R L 4
INPUTS
R L
5
R L
7
R L 1 R L 2 R L 3 R L 4
OUTPUTS
R L 5 R L 6 R L 7 R L 8 R L
2
R L 6 R L 8 R
ADDRESS
Connect audio devices, such as an audio amplifier or powered speakers to the eight sets of 3.5 mm, 5-pole captive screw connectors marked “Outputs.” The connectors output the selected unamplified, line level audio (see
on page 12 to properly wire an output connector).
By default, audio and video use different boards, so that audio breakaway is switched separately. This is done via the front panel, Ethernet, or the RS-232 or RS-422 link, allowing selection from any of the audio input sources (see
on page 13,
on page 34, SMX Control Software
on page 59, or
HTML Control and Configuration on page 87 for control details).
m Plane address rotary switch — This 16 position rotary switch defines a plane address for up to 16 I/O boards. To set an address, insert a small screwdriver in the slot and rotate it to the desired number (0-9, A-F). Each plane address is then identifiable during
SMX control and configuration.
ADDRESS
SMX System MultiMatrix Switcher • Installation and Cabling 9
Other I/O Boards
SMX 84 USB
Connect host devices (such as a PC) to any of the USB Type B Hosts ports (inputs).
Connect suitable USB devices (such as a mouse or keyboard) to any of the USB Type A
Device Hubs ports (outputs).
NOTES:
• There are 3 USB hubs in series within the USB boards. Per USB specifications, up to
5 USB hubs can be used in a system.
• USB boards cannot be cascaded.
• Appropriate USB Type A to USB Type B cables or adapters may be required for USB
Type B input signals.
HOSTS
1
A
2
DEVICE HUBS
B A
3
B
4
1 2 3 4 5 6 7 8
ADDRESS
A B A B
Features of SMX USB boards:
Peripheral emulation — Constantly emulates an HID (Human Interface Device) compliant mouse and keyboard to any connected host without necessitating any ties to an output device. This feature facilitates a problem-free boot up and is evident in the device manager of the host PC as it constantly reports a mouse and keyboard are connected to it.
Host emulation — Emulates a host to multiple standard keyboards and mice. Connected keyboards and mice operate as one unit.
The default setting for host emulation is Off. To enable or disable host emulation (see the
on page 52 or USB Settings/Status on page 67).
NOTES:
• When host emulation is enabled, Device Hubs ports continually provide power to attached peripherals. However, they will not function until ties are made to a host.
• Host emulation is valid through a hub or USB extender.
• If non-HID devices are connected to the Device Hubs ports, host emulation is disabled.
Hot key switching — Routes or makes a tie between a specific input using a specific combination of key presses on an attached keyboard and an output. To make a tie, press
<Ctrl> + <Shift> + <desired input to be tied>.
NOTES: Hot key switching can be executed only under the following conditions:
• Host emulation is enabled for the desired output.
• The output has a “standard” keyboard (it cannot require special USB drivers) to execute the button combination for hot key switching.
KVM application — The USB and video board must be set to the same plane address in order to switch the keyboard, video, and mouse together during ties.
SMX Frame and I/O Board Installation
If the SMX is to be rack mounted, it is important to mount it before cabling it (see
on page 115).
Installing the I/O Boards
The I/O boards on any unit may vary with each installation, depending on desired configuration and use. Each board has input and output connectors that are clearly marked, and a 16-position rotary switch used to set the I/O plane address.
SMX System MultiMatrix Switcher • Installation and Cabling 10
NOTES:
• The boards are hot-swappable: they can be installed or removed without turning off or disconnecting the power. However, turning the power off prior to installing or removing boards is recommended.
• Use ESD precautions when installing a board to avoid damaging it. Keep the board in the anti-static bag until needed. Use proper grounding techniques during installation.
See Frames and I/O Boards on page 114 for a full list of available boards for the SMX.
Installing new boards into an empty SMX frame
1. Remove as many of the blanks plates from the rear of the unit as needed.
2. When ready, remove the board from the anti-static bag, taking care not to touch any of the components on the board. Slide the board into the open rear slot (see figure 4), carefully aligning it with the plastic slides in the frame. Push the board firmly into place.
REMO
TE
RS
/RS
232
422
US
LIS TED
AU DIO
17 TT
/VID EO
ATU
100
AP PAR
-24
50-
1.3
A M
60H
AX
Y
C
1
5
10
10
2
COMPUTER IN
3
7
6
11
12
13
14
4
8
15
AN
E A DR
ES
16
Y
S-VIDE
O
C
PL AN
E A DR
ES
16
15
14
11
12
VIDEO INPUTS
13
3
4
PL
AN E A
DR
DIGI TAL
VID
EO
ES
PL
AN
DR
E A
ES
2
INPUTS
1
SDI / HDSDI INPUTS
1
1
5
10
11
2
T
COMPUTER OU 3
7
6
13
14
12
14
12
11 VIDEO OUTPUTS
13
10
4
8
15
15
4
16
Y
16
C
2
OUTPUT
S
S
SDI / HDSDI OUTPUT
3
3
R
1
R
2 R
10
R
11 R
N
P
U
T
S
9 R
4 R
6 R
5
R
13
R
14
R
8 R N
7 R
15
R
16
P
U
T
R
S
12
R
AN
E A DR
ES
1
R
O
U
T
P
U
T
S
9 R
3
R
2 R
10
R
11 R
4 R
5 R
6 R
7 R
15
R
16
8
R
O
U
T
P
R
U
T
S
13
R
14
R
12
R
Optional
Board
(audio shown)
Figure 4. SMX Frame Rear Showing Board Installation
3. Tighten down the screws on each end of the board.
NOTE: Use a tool to fully tighten the screws after initial installation and subsequent removal and replacement of the boards.
4. Repeat steps 1 through 3 for all boards needing installation.
NOTE: If the unit is connected via RS-232 or RS-422, it responds with Reconfig when a board is installed or replaced.
The SMX is now ready for cabling (see
on page 8 for details).
Replacing an existing I/O board
1. Remove any input and output cables for the I/O board being replaced.
2. Loosen the outer screws on the existing board and remove it from the unit.
3. Slide the replacement board firmly into place and tighten down the screws.
4. Repeat for all boards to be replaced. Any new boards are now ready for cabling.
To configure the SMX with the new cards, see Operation
on page 13. For alternative
configuration methods for the SMX, see SIS Configuration and Control
on page 59, and HTML Configuration and Control
on page 87.
SMX System MultiMatrix Switcher • Installation and Cabling 11
Wiring the Audio Connectors
Connect audio input devices to the 3.5 mm, 5-pole captive screw connectors (up to two groups of eight sets possible).
Wire the input connectors as shown in figure 5.
Tip
Ring
Sleeves
Tip
Ring
Tip
Ring
Sleeve
Balanced Audio Output Input Balanced Mono Input
(high impedance)
Tip
Sleeve
Tip
Sleeve
Unbalanced Stereo Input
Tip
Sleeve
Unbalanced Mono Input
Do not tin the wires!
Figure 5. Captive Screw Connector Wiring for Audio Signals
NOTE: When making connections for the SMX from existing audio cables (see figure 7). A mono audio connector consists of the tip and sleeve, whereas a stereo audio connector consists of the tip, ring, and sleeve. The tip, ring, and sleeve wires are also shown above on the captive screw audio connector diagram (balanced inputs, see figure 6).
Tip (+)
Tip (+)
Ring (-)
Sleeve ( )
RCA Connector
Sleeve ( )
3.5 mm Stereo Plug Connector
(balanced)
Figure 6. RCA Audio Connectors
Wire the output connectors as show in figure 7.
No Ground Here
Tip
Ring
Sleeves
Tip
Ring
Tip
Sleeves
Tip
Balanced Audio Output
No Ground Here
Unbalanced Audio Output
Do not tin the wires!
Figure 7. Captive Screw Connector Wiring for Audio Output
CAUTION: For unbalanced audio, connect the sleeves to the center contact ground.
Do not connect the sleeves to the negative (-) contacts.
SMX System MultiMatrix Switcher • Installation and Cabling 12
Operation
This section discusses the operation of an SMX series device through the front panel buttons and includes:
•
•
•
•
Configuring the Rear Panel RS232/RS422 Port
•
Viewing and Adjusting the Audio Input Level
•
Viewing and Adjusting the Audio Output Volume
•
•
Front Panel Overview
SMX controls and indicators are shown in figure 8. They include I/O plane selection buttons, input and output selection buttons, control buttons (Enter, Preset, View, and Esc) and power indicator LEDs for the main board and I/O cards. A 2.5 mm configuration port is also on the front panel.
All buttons can be relabelled as desired (see Replacing Buttons Labels section on
page 117).
NOTE: Some models have a blank front panel (no buttons) (see
on page 34, SMX Control Software
on page 59, and
1
2
3
0
I/O PLANE SELECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
CONFIG
CONTROL
ENTER PRESET
VIEW
P
O
W
E
R
MAIN
I/O CARDS
ESC
SMX SERIES SWITCHER
6
Figure 8. SMX Series Matrix Switcher Front Panel Features a I/O Plane Selection buttons (0-15) b Inputs buttons (1-16) c Outputs buttons (1-16) d Control buttons (Enter, Preset, View, and Esc) e Power status LEDs f Config port
4
5
SMX System MultiMatrix Switcher • Operation 13
I/O Plane Selection Buttons
a Plane selection buttons — The buttons, labeled 0 through 15, allow plane selection and identify any tied inputs and outputs on the selected plane. These correspond to the board rotary switch settings.
Input and Output Buttons
b Input selection buttons — Input buttons 1 through 16 select inputs to tie to outputs, remove or replace ties, and to view ties. Any input can be tied to any output as video, audio, or both (see the
on page 16 for more details).
NOTE: Input and output buttons light (or flash) green for video signals, red for audio signals, and bright amber for both video and audio signals.
Input buttons are also used to:
•
•
Save and recall global presets (1 through 16)
Save and recall plane presets (1 though 10)
•
•
•
•
•
•
Display the output audio volume level
Display RGB delay up to 5 seconds (inputs 1-10), in 0.5 second intervals, (for SMX
VGA and RGBHV boards only)
Select inputs to view or adjust the audio level of that input
Select inputs to enable muting or unmuting of tied outputs
Set button backlight to On or Off (press and hold inputs 1 and 2 simultaneously)
Activate audio gain and output volume control (press any button twice, when the
SMX is in view mode with an audio plane selected).
c Output selection buttons — The output buttons 1 through 16 select the output to tie to any selected active input, and identify existing ties (video, audio, or both) active on that selected output (see
on page 16 and Viewing Ties on
page 18 for method).
Any output can be tied to any input as video, audio, or both (see Front Panel
on page 16 and
Creating Ties on page 17 for more details).
Output buttons are also used to:
• Save and recall global presets (17 through 32, using outputs 1 though 16)
•
•
Display the input audio level
Show which outputs are tied to any selected input
•
•
•
Select outputs for muting or unmuting
Select an audio output for volume adjustment
Activate audio gain and output volume control (press any button once when an audio plane is selected and flashing
NOTE: Throughout this guide, the front panel buttons status is shown as unlit, lit, or flashing.
Unlit Lit Flashing
SMX System MultiMatrix Switcher • Operation 14
Control Buttons
d Control selection buttons — These four buttons give direct access to the enter
(save), preset, view, and Esc (exit) controls. Each button has a separate function.
NOTES:
•
See Configuring the Rear Panel RS232/RS422 Port on page 26 for serial
port configuration details.
•
See Setting the Front Panel Locks (Executive Modes) on page 25 for
executive modes details.
Enter button — The Enter button flashes green when a change to an input or output tie is pending, or red when a preset recall is pending. Pressing the flashing button saves the change or recalls the preset, and the Enter button and any lit input and output buttons extinguish (see
on page 16).
Preset button — The Preset button gives access to recall or save up to 32 global presets (using I/O buttons 1 through 16), and 10 plane presets (using input buttons 1 through 10). The button lights red when pressed. Upon recalling or saving the preset,
the button and all input and output buttons (lit red) are extinguished (see Front Panel
on page 16 and
Saving and Recalling I/O Presets
on page 22).
NOTE: Global presets save and recall the configuration for all planes. Plane presets save and recall the configurations for a specific plane without affecting the other plane connections.
View ( < ) button — This button, when pressed and released, lights red and allows quick viewing of existing input and output ties. When the button is lit, after selecting a plane and an associated input, muted outputs flash and untied outputs light the appropriate signal color (red, green, or amber). Tied outputs remain unlit.
NOTE: Use this button to decrease settings for RGB delay, input audio level, and
output audio volume. This button also mutes and unmutes outputs (see Muting or
Unmuting a Video, Audio, or Video and Audio Output on page 20).
Esc ( > ) button — This button, when pressed, flashes green once and all lit control, plane, input, and output buttons are extinguished.
NOTE: Use this button to increase the RGB delay, input audio level, and output audio volume.
Also, when used in combination, the buttons have the following functions:
Control Button Combination
Enter Preset View Esc
Function
Selects the serial port configuration.
Preset View
View
Esc Toggles between executive modes 2x and 0x.
Esc Toggles between executive modes 2x and 1x or initiates a system reset.
Power Indicator LEDs
e Power indicator LEDs — These two LEDs, labeled “Main” and “I/O Cards,” light green when power is applied to the unit. The LEDs light red when the main or redundant power supply fails.
SMX System MultiMatrix Switcher • Operation 15
Front Panel Configuration Port
f Configuration port — This 2.5 mm port (jack) can be used to configure the SMX during setup via RS-232, and has an independent protocol from the primary RS-232 port on the rear panel. Use the 2.5 mm configuration cable, part number 70-335-01
(see figure 9) for connection to your PC serial port.
RS-232 protocol (default): 9600 baud, 1 stop bit, no parity, 8 data bits, no flow control.
6 feet
1
6
9
5
Tip
Ring
Sleeve (Gnd)
9-pin D
Pin 2
Pin 3
Pin 5
Connection
Computer Rx line
Computer Tx line
Computer signal ground
TRS Plug
Tip
Ring
Sleeve
Figure 9. Front Panel 2.5 mm Port Configuration Cable
NOTE: This port does not support RS-422.
Powering Up
When power is applied to the SMX, it undergoes a start-up self testing sequence:
1. All buttons flash green, red, and then amber, before extinguishing.
NOTE: The order in which the colors are displayed may vary.
2. The two LEDs light green to indicate power is present to the main unit and I/O boards.
NOTE: This sequence also occurs when the unit restarts after firmware uploads.
Front Panel Operation
This section covers basic setup and configuration of the SMX using the front panel.
Ties — General Information
• During any operation of front panel buttons, any active input, output, and control buttons stay lit or blink for 30 seconds. If, during that 30 seconds, no button is pressed, a time-out occurs and all buttons go out. The operation must be restarted.
• To enable any selected input signal to be viewed on a display device, the input must be tied to an output on the same plane.
• An output can be tied to one input only, but an input can have multiple outputs.
• If an input with no existing tie is selected, only that input button lights when pressed. No output buttons light.
• When a plane and an input are selected, the associated output buttons flash the appropriate color to indicate tentative ties. Buttons for outputs to the selected input light steadily in the appropriate color.
• If a tie is made between an input and an output and the selected output was previously tied to another input, the older tie is broken when the Enter button is pressed.
SMX System MultiMatrix Switcher • Operation 16
• If any associated (lit) output button (an existing tie) is toggled off by pressing the button and the Enter button is pressed, the existing tie to that output is lost.
• Ties can be made using SIS commands via RS-232, RS-422, Ethernet, the SMX
Control Software program, or the internal Web pages (see
on page 34 for RS-232 and RS-422 control,
page 59 for Software, or HTML Configuration and Control
on page 87 for HTTP methods).
Creating Ties
To make input ties to untied outputs:
An example of creating an input to output tie
The following shows how to create a tie (input 7 on plane 0 to output 4 in this example).
1. Press and release the Esc button to clear any pending input, output, or control button changes. The Esc button flashes green once.
2. Press and release the I/O Plane Select button for the desired configuration.
NOTE: The I/O Plane button and Input button 1 lights, indicating the signal type: green for video, red for audio, or amber for both video and audio signals. In the examples below, the plane carries a video signal only.
Step 2.
Press and release the desired I/O Plane Select button.
I/O PLANE SELECT
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Step 2.
an audio plane, or
green if on a video plane, red if on
Press and release the desired I/O Plane Select button.
Step 3.
I/O PLANE SELECT
I/O plane and Input buttons light green if on a video plane, red if on
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Input 1 extinguishes.
INPUTS
Currently tied outputs light according to the signal type of the output.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
3.
Figure 10. Select I/O Plane, then an Input — an Example (Steps 2 and 3)
Input 1 extinguishes.
OUTPUTS
INPUTS
Currently tied outputs light according to the signal type of the output.
OUTPUTS
Press and release Enter.
Press and release the desired input button (see figure 10). This button lights according to the plane signal type: green (video), red (audio), or amber (both).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
PRESET VIEW ESC
Press and release Enter.
Step 4. INPUTS
Press and release the desired output button (flashes).
The Enter button also flashes ( green).
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
All buttons extinguish .
ENTER PRESET
VIEW ESC
OUTPUTS
Step 4.
Press and release the desired output button (flashes).
The Enter button also flashes ( green).
All buttons extinguish .
Figure 11. Select the Outputs, then Press Enter — an Example (Steps 4 and 5)
4. Press and release the output buttons (see figure 11). The selected output buttons flash.
The enter button flashes green.
5. Press and release the Enter button to make the tie. The plane selection, input, output, and Enter buttons all extinguish.
NOTE: Repeat steps 2 through 5 if the Enter button extinguishes before being pressed.
SMX System MultiMatrix Switcher • Operation 17
Viewing Ties
Any existing input to output tie can be viewed.
An example of viewing a set of video or audio ties
The following shows how to view existing ties on any allocated plane (here planes 0 and 2).
1. Press and release the View button (lights red). The last plane button used (here 0) lights green, and untied output buttons light the appropriate color for the plane signal type,
(green for video, red for audio, amber for both).
NOTE: If all output buttons light, no outputs are tied. If no output buttons light, all outputs are tied. The maximum number of buttons that may light corresponds to the number of outputs on the plane card (4, 8, or 16).
Step 1.
Press the View button (lights red).
C O N T R O L
ENTER PRESET VIEW ESC
The last plane button used lights green (if a video plane),
red (if an audio plane), or amber (if a video and audio plane).
I/O PLANE SELECT
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Untied buttons (Outputs 1, 2, 6, 7, and 12 through 16) light
green, red, or amber . No input buttons light.
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Figure 12. Viewing Ties — an Example of Untied Outputs (Step 1)
2. Press and release another plane selection button to view ties for that plane.
3. To view the input tied to it, press any of the unlit output buttons (in the example below, buttons 10 through 12, and 16). The untied output buttons extinguish, and the previously tied output buttons (10 through 12 and 16) and the associated tied input button (3) light the appropriate color (see figure 13).
Step 2.
Press plane button 3 (lights red - audio plane).
0
I/O PLANE SELECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Untied output buttons light, indicating signal type: red (audio).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Step 3.
Press a tied output button (10).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Tied outputs (10 through 12, and 16) and associated input (3) light the same color.
Figure 13. Viewing Ties — an Example of Tied Outputs (Steps 2 and 3)
NOTE: To clear the lights after viewing, press and release the Esc button. This does not clear or change any existing ties.
SMX System MultiMatrix Switcher • Operation 18
Removing Ties
Any video or audio tie can be removed from an existing set of ties.
An example of removing ties from an existing set of ties
In this example, input 3 on video plane 0 is already tied to outputs 2, 4, 6, and 7. The ties to outputs 4 and 7 are to be removed.
1. Press and release plane button 0 which lights green. Input button 1 lights the plane signal type: green for video, red for audio, amber for video and audio.
2. Press and release input button 3 (lights). Tied outputs (2, 4, 6, and 7) light the same color as the input button. Input 1 extinguishes (see figure 14).
Step 1.
Press plane button 0 (lights green).
I/O PLANE SELECT
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Input button 1 lights, indicating signal type: green (video) or red (audio).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Step 2.
Press Input 3 button (lights).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Tied outputs (2, 4, 6, and 7) light same color, and Input 1 extinguishes.
Figure 14. Removing Ties — an Example (Steps 1 and 2)
3. Press and release outputs buttons 4 and 7. They begin flashing (indicating that they are ready for removal), and the Enter button flashes green.
4. Press and release the flashing Enter button (see figure 15). The two ties are removed, and all button lights extinguish.
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Step 4.
Press and release the
Enter button to remove ties .
C O N T R O L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Step 3.
Press and release Output 4 and 7 (flashes).
Enter button also blinks ( green).
ENTER PRESET VIEW
All buttons extinguish .
ESC
Figure 15. Removing Ties — an Example (Steps 3 and 4)
SMX System MultiMatrix Switcher • Operation 19
Replacing Ties
An input tied to an output can be replaced with another input, as long as that input is of a similar type or plane (for example, video for video and audio for audio).
An example of replacing an existing tied input with another input
In the following example, input 2 on video plane 0 is tied to output 1, 4, and 8. The input 2 signal to output 1 is to be replaced by the input 7 signal, also on plane 0, and already tied to outputs 3 and 6.
1. Press and release plane button 0. It lights green. Input button 1 lights, indicating plane signal type (green for video, red for audio, amber for both).
2. Press and release input button 7, which lights. Tied output buttons (3 and 6 in this example) light the same color as the input button. The input 1 button extinguishes.
Input 2 is tied to outputs 1, 4, and 8 (all lit).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Step 1.
Press and release the I/O Plane 0 button. It lights green.
I/O PLANE SELECT
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Input button 1 lights green (video plane), red (audio plane), or amber (video and audio plane).
Step 2.
Press Input button 7 (lights).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Outputs 3 and 6 light the same color as the input 7 button . Input 1 extinguishes.
Step 4.
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Press and release Enter.
C O N T R O L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Step 3.
Press and release Output 1 button (flashes).
Enter blinks ( green).
ENTER PRESET VIEW ESC
All buttons extinguish .
Figure 16. Replacing Ties — an Example
3. Press and release the output 1 button. This button flashes the same color as the input button, and the Enter button flashes green. The other tied buttons (3 and 6 in this example) remain lit (see figure 16).
4. Press and release the Enter button. All button lights extinguish.
Muting or Unmuting a Video, Audio, or Video and Audio Output
Any output signal can be muted or unmuted (see the Note below). Muted signals are indicated by a flashing output button when in View mode and with the selected plane buttons lit. The tie for the muted signal still exists.
NOTE: When the front panel is in lock mode 2, the output mute status can be viewed only and no changes to the mute status (muting or unmuting a signal) can be made from the front panel.
SMX System MultiMatrix Switcher • Operation 20
Muting an output
To mute an output signal, do the following:
1. Press and release the Esc button to clear all pending changes.
2. Press and release the View button, which lights red. The previously selected plane button and untied output buttons light (see figure 17), or flash if the outputs are already muted. Tied outputs remain unlit.
NOTE: For video signals, output buttons light or flash green; for audio only signals, the buttons light or flash red, and for video and audio signals, the buttons light or flash amber.
Step 2.
Press and release the View button (lights red) .
C O N T R O L
ENTER PRESET VIEW ESC
The last plane button used lights.
Step 3.
Press and release the desired I/O Plane (here plane 2).
The plane button and any untied outputs light. Muted outputs flash. Tied outputs remain unlit.
0
I/O PLANE SELECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Figure 17. Muting Output Signals — an Example (Steps 2 and 3)
3. Select the applicable plane which lights. The output buttons light if they are untied or flash if they are tied and muted in the signal type color. Tied outputs remain unlit.
4. Press and hold the desired output button for 2 seconds or until the button flashes, then release. The signal is now muted (see figure 18).
NOTE: If the button flashes red, the audio signal is muted. If the button flashes green, the video signal is muted. If it flashes amber, both are muted.
Step 4.
Press and hold the desired output buttons for 2 seconds.
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Step 5.
Press and release the
View button.
C O N T R O L
ENTER PRESET VIEW ESC
Each selected button flashes ( green, red, or amber).
All buttons extinguish .
Figure 18. Muting Output Signals — an Example (Steps 4 and 5)
5. Press and release the View button. All buttons extinguish.
NOTE: For video, only RGB is muted. Sync is not muted.
SMX System MultiMatrix Switcher • Operation 21
Unmuting an output
To unmute an output signal, do the following:
1. Press and release the Esc button to clear all pending changes.
2. Press and release the View button, which lights red.
3. Press and hold the desired muted output button, until the button light ceases to flash and remains lit (approximately 2 seconds). The signal is now unmuted.
NOTE: Output buttons with muted signals flash the appropriate color (green for video, red for audio, or amber for both). Output buttons with unmuted signals appropriate color.
4. Press and release the View button. All buttons extinguish.
Saving and Recalling I/O Presets
The SMX has a total of 32 global preset addresses available (using I/O buttons 1 through
16) and 10 plane preset addresses (using Input buttons 1 through 10).
NOTE: A global preset saves and recalls configurations for all planes. A plane preset saves and recalls the configurations for a specific plane without affecting the other plane connections.
Each global preset can be saved and recalled using the front panel input and output buttons, with presets 1 through 16 assigned to the input buttons and presets 17 through 32 assigned to the output buttons. Likewise, plane presets are saved to and recalled from input buttons 1 through 10. Any current tie configuration can be saved to any one of the preset locations, in any order. Saving the current configuration to an existing preset overwrites the existing preset with the new configuration.
PLANE
GLOBAL
Preset
1
Preset
1
Preset
2
Preset
2
Preset
3
Preset
3
Preset
4
Preset
4
Preset
5
Preset
5
Preset
6
Preset
6
Preset
7
Preset
7
Preset
8
Preset
8
Preset
9
Preset
INPUTS
9
Preset
10
Preset
10
Preset
11
Preset
12
Preset
13
Preset
14
Preset
15
Preset
16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
GLOBAL Preset
17
Preset
18
Preset
19
Preset
20
Preset
21
Preset
22
Preset
23
OUTPUTS
Preset
24
Preset
25
Preset
26
Preset
27
Preset
28
Preset
29
Preset
30
Preset
31
Preset
32
Figure 19. Preset Addresses
When a preset is recalled, it replaces the current (active) configuration, which is then lost unless already saved to a different preset location. The recalled preset overwrites all of the current configuration ties with the recalled configuration.
NOTES:
• Presets cannot be viewed from a front panel unless recalled as the current configuration. Presets can be seen using the Windows based SMX Control Program.
• The current configuration and all other presets are stored in non-volatile memory.
When power is removed and restored, the current configuration remains active and all presets are retained.
• Ties for all I/O planes are stored and recalled. Audio gain settings are not saved with the preset and do not change when a preset is recalled.
• When the plane preset mode is active, input buttons light for all saved presets.
SMX System MultiMatrix Switcher • Operation 22
Saving or recalling a global preset
1. Press the Esc button to clear all pending changes. The button flashes green once.
2. Saving a global preset — Press and hold the Preset button until it flashes red.
OR
Recalling a global preset — Press and release the Preset button (lights red). All previously saved presets also light red. Proceed to step 4.
Step 2.
To save a global preset, press and hold the Preset button until it flashes red .
Buttons for any previously saved presets light red
(here preset 8, 18, and 32).
C O N T R O L
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
ENTER PRESET VIEW ESC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
NOTE: To recall a global preset, press and release the Preset button (lights red) .
Step 3.
Press and release the desired (unlit or lit) input or output button (here output 5, preset 21). The button flashes red.
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Step 4.
Press the Enter button to save or recall preset.
C O N T R O L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
ENTER PRESET VIEW
Enter button also blinks ( red).
All buttons extinguish .
NOTE: To recall a global preset, press and release a lit Preset button .
ESC
Figure 20. Saving or Recalling a Global Preset — An Example
(Steps 2 through 4)
3. Press and release a desired input or output button to select the address to save the current configuration to. The Address, Preset, and Enter buttons flash red.
NOTE: A preset can be saved to any lit or unlit button. Only presets with lit buttons can be recalled. When a preset is saved to a lit (previously saved button, the stored data is overwritten with the new data. Only one preset can be saved to an address at a time.
4. Press and release the Enter button. The preset is saved or recalled as specified.
Saving or recalling a plane preset
1. Press the Esc button to clear all pending changes. The button flashes green once.
2. Saving a plane preset — Press and hold the Preset button until it flashes red, then select a plane.
OR
Recalling a plane preset — Press and release the Preset button , which lights red.
All previously saved presets light red, then select a plane.
NOTE: Lit presets are global presets, not plane presets.
3. Press and release a plane button. The button lights.
NOTE: The lit buttons for global presets extinguish, and the buttons for any saved plane presets light.
SMX System MultiMatrix Switcher • Operation 23
4. Press and release the desired input button (1-10) to select a plane preset address.
Saving a plane preset — The Address, Preset, and Enter buttons flash crimson.
Recalling a plane preset — The Address and Enter buttons flash crimson.
NOTE: A preset can be saved to any lit or unlit input button (1 through 10). Only presets with lit buttons can be recalled. When a preset is saved to a lit button
(already containing a preset), the stored data is overwritten with the new data. Only one plane preset can be saved to an address at a time.
5. Press and release the Enter button. The plane preset is saved or recalled.
Step 3.
Press desired plane button (here plane 0).
0
I/O PLANE SELECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Plane button lights green.
Buttons for any previously saved plane presets light red (here preset 7).
Step 4.
Press and release the desired (unlit or lit) input button 1-10
(here preset 3). The selected button flashes red.
Step 5.
Press the Enter button to save or recall the preset.
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
C O N T R O L
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Enter button also blinks ( red).
ENTER PRESET VIEW
All buttons extinguish .
ESC
NOTE: To recall a plane preset, press and release the Preset button.
Select a plane, then press and release a lit preset button.
Figure 21. Saving or Recalling a Plane Preset — an Example
(Steps 3 through 5)
Setting RGB Delay (VGA and RGBHV Boards Only)
NOTE: This feature is applicable only for VGA and RGBHV boards and can not be set via the front panel when the SMX is in lock modes 1 or 2.
1. Press the Esc button to clear all pending changes. The button flashes green once.
2. Select a VGA or RGBHV plane.
3. Press and hold View for 3 seconds. The selected plane button flashes green.
4. Select the output to delay. The button lights.
5. Using View and Esc, adjust the time duration for the delay (up to 5 seconds maximum).
Each lit input button corresponds to a half-second delay.
NOTE: No input buttons lit signifies zero delay, 10 buttons lit signifies 5 seconds delay.
SMX System MultiMatrix Switcher • Operation 24
Step 2.
Press and release a VGA or RGBHV plane button (lights green or amber).
0
I/O PLANE SELECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Step 3.
Press and hold the View button until the plane button flashes green.
C O N T R O L
ENTER PRESET VIEW ESC 0
I/O PLANE SELECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Step 4.
Press and release the output button to be delayed (here output 8). Input buttons light to show the current RGB delay (here 2.5 seconds).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
C O N T R O L
VIEW
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
ENTER PRESET ESC
Step 5. Press View to decrease or Esc to increase the delay.
The maximum RGB delay is 5 seconds .
Figure 22. Setting RGB Delay — an Example (Steps 2 through 5)
6. Press and release the Enter button to save the settings and exit the RGB delay mode.
Setting the Front Panel Locks (Executive Modes)
The SMX has three levels of front panel security lock that limit the operation of the switcher from the front panel. The three levels are:
• Lock mode 0 — The front panel is completely unlocked, and all front panel controls are available. Basic and advanced features are available.
• Lock mode 1 — All changes are locked from the front panel (except for setting Lock mode 2). Only View mode is available.
• Lock mode 2 — Basic functions are unlocked. Advanced features are locked and can be viewed only (default mode).
Basic features consist of:
•
•
•
•
Making ties
Saving and recalling presets
Setting input audio gain and attenuation
Changing lock modes
Advanced features consist of:
• Setting video and audio output mutes
•
•
•
Setting audio output volume
Setting RGB delay (VGA, RGBHV boards)
Setting the rear panel report port protocol and baud rate
NOTE: The SMX is shipped from the factory in lock mode 2 (see
SIS Configuration and Control on page 34 to set lock modes using SIS commands).
SMX System MultiMatrix Switcher • Operation 25
Selecting lock mode 2 or toggling between mode 2 and mode 0
NOTES:
• If the SMX is in lock mode 0, this procedure selects mode 2. The Preset, View, and
Esc buttons flash green twice.
• If the SMX is in lock mode 2, this procedure selects mode 0 (unlocks the switcher).
The View and Esc flash green twice.
Toggle the lock on or off by pressing and holding the Preset, View, and Esc buttons simultaneously until the buttons flash (approximately 2 seconds).
C O N T R O L
ENTER PRESET VIEW ESC
C O N T R O L
ENTER PRESET VIEW ESC
C O N T R O L
ENTER PRESET VIEW ESC
Press and hold for
2 seconds.
Lock mode 2
Preset, View, and
Esc flash.
Press and hold for
2 seconds.
Figure 23. Setting the Executive Lock Mode 2
C O N T R O L
ENTER PRESET VIEW ESC
Lock mode 0
View and Esc flash.
Selecting lock mode 1 or toggling between mode 2 and mode 1
NOTES:
• If the SMX is in Lock mode 1, this procedure selects mode 2. The Preset, View, and
Esc buttons flash green twice.
• If the SMX is in Lock mode 2, this selects mode 1. The View, and Esc buttons flash green twice.
Toggle the lock on and off by pressing and holding the View and the Esc button simultaneously until the buttons flash (approximately 2 seconds).
C O N T R O L
ENTER PRESET VIEW ESC
C O N T R O L
ENTER PRESET VIEW ESC
C O N T R O L
ENTER PRESET VIEW ESC
Press and hold for
2 seconds.
Lock mode 1
View and Esc flash.
Press and hold for
2 seconds.
Figure 24. Setting the Executive Lock Mode 1
C O N T R O L
ENTER PRESET VIEW ESC
Lock mode 2
Preset, View, and
Esc flash.
Setting Background Illuminations
The background illumination can be toggled on or off (default state) as desired from the front panel. When the background illumination is on, the buttons are lit 25% amber. To toggle button background illumination off or on, do the following.
• Press and hold inputs 1 and 2 simultaneously, for 3 seconds. All buttons extinguish if lit amber, or light amber if already off.
NOTE: When in lock mode 1, background illumination cannot be changed.
SMX System MultiMatrix Switcher • Operation 26
Configuring Via the Rear Panel RS232/RS422 Port
The SMX rear panel 9-pin D com port can be configured through the front panel using the
Control buttons and I/O plane buttons 0 and 1.
NOTE: RS-232 or RS-422 configuration via the front panel is not possible when the unit is in lock mode 2.
The port can also be configured using SIS commands via Telnet, RS-232, or RS-422 (see
SIS Configuration and Control on page 34 for using SIS commands).
Using the Front Panel
NOTE: This function is available only when the unit is in Lock mode 0.
1. Press and hold the Enter, Preset, View, and Esc buttons simultaneously until the control buttons and I/O plane buttons 0 and 1 light.
2. Use the control buttons to select the baud rate:
• Enter = 9600 • Preset = 19200 • View = 38400 • Esc = 115200
The selected baud rate button flashes.
3. Use the I/O plane buttons (0 and 1) to select the connection type. The selected connection type button flashes.
• I/O plane button 0 = RS-232 • I/O plane button 1 = RS-422
4. Press any input or output button to exit configuration mode.
Viewing and Adjusting the Audio Input Level
The audio level of each input can be displayed and adjusted through a range of -18 dB through +24 dB. It can be adjusted from the front panel, through RS-232 or RS-422, or
through Ethernet (see SIS Configuration and Control on page 34 to make adjustments
using SIS commands).
Using the Front Panel
1. Press and release the Esc button to clear all pending changes (flashes green once).
2. Select the audio plane to be viewed and adjusted. The button lights red or amber.
3. Press and hold any I/O button until the audio plane button flashes red (approximately
2 seconds), and then release the button. All I/O buttons extinguish.
4. Press and release a desired input button. It lights green. The input audio level is displayed by the lit and flashing output buttons (see the
on page 28 for button lighting and dB lighting) and the color indicates the polarity (+ is green; – is red).
5. Press and release the View (<) button for attenuation (–), and Esc (>) button for gain (+)
to increase or decrease the audio level (see figure 25 ).
See the
Audio Input Level Adjustment Lighting Table
on page 28 for a table of audio level settings.
SMX System MultiMatrix Switcher • Operation 27
dB
Level
21
20
19
18
17
16
24
23
22
15
14
13
12
11
10
Color green green green green green green green green green green green green green green green
Step 1 – Press and release Esc.
Flashes green once and clears pending changes .
Step 2 – Press audio I/O plane button to be adjusted (here button 4).
0
I/O PLANE SELECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Plane button lights red, indicating an audio (signal) plane.
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
I/O button 1 lights red.
Step 3 – Press and hold any I/O plane button until audio plane button flashes.
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
I/O button momentarily lights red until audio plane button flashes. I/O button 1 turns off.
0
I/O PLANE SELECT
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Selected audio plane button flashes red and I/O button turns off.
Step 4 – Press the button for the input needing the audio level adusted (here 8).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Selected input button lights green, and View button lights red.
The current audio level dB is indicated by the lit and flashing output buttons.
Here buttons 1-4 lit and 5 flashing red indicates an input level of -9 dB.
(See Figure 25 for button lighting and dB levels.)
NOTE: View button lights red and output buttons are red when current audio
level is negative dB, and Esc button lights red and output buttons are
green when it is positive dB.
Step 5 – Press and hold View to decrease or Esc to increase audio level.
C O N T R O L
ENTER PRESET
VIEW ESC
Buttons
Lit or
Flashing
12
12 flash
11
11 flash
10
10 flash
9
9 flash
8
8 flash
7
7 flash
6
6 flash
5
Selected control button lights red (in this example, Esc was pressed).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
Selected input button remains lit. Outputs light, flash, or go out as the level changes.
Here the dB is raised to +20 dB. Outputs 1-10 are lit green.
Additional inputs can be adjusted by repeating steps 4 and 5.
Step 6 – Press Enter to leave the input audio level adjustment mode.
All buttons go out.
Figure 25. Adjusting the Input Audio Levels — an Example (Steps 5 and 6)
6. If desired, select additional inputs can be set by pressing their input button.
7. Press and release the Enter button (or wait 30 seconds) to exit the audio display and adjustment mode. The audio plane button extinguishes.
NOTE: There is only one audio level setting per input on a specific plane. It is shared by the left and right audio inputs. The audio levels are stored in non-volatile memory. When power is removed and restored, they are retained.
If the audio is set to “follow-all” upon initial selection in step 2, the I/O plane and associated input and output buttons light amber. When an input or output button is held for 2 seconds (step 3), the I/O plane button flashes red.
>
>
>
>
>
>
>
>
>
>
>
>
>
>
>
+/-
Audio Input Level Adjustment Lighting dB
Level
Color
Buttons Lit or Flashing +/dB
Level
4
3
6
5
2
1
9
8
7
0
-1
-2
-3
-4
-5 green green green green green green green green green red red red red red
5 flash
4
4 flash
3
3 flash
2
2 flash
1
1 flash not lit
1 flash
1 flash
2 flash
2 flash
3 flash
>
>
>
>
>
>
>
>
>
<
<
<
<
<
-9
-10
-11
-12
-13
-14
-6
-7
-8
-15
-16
-17
-18
Color red red red red red red red red red red red red red
Buttons Lit or Flashing +/-
3 flash
4 flash
4 flash
5 flash
5 flash
6 flash
6 flash
7 flash
7 flash
8 flash
8 flash
9 flash
9
<
<
<
<
<
<
<
<
<
<
<
<
<
SMX System MultiMatrix Switcher • Operation 28
Viewing and Adjusting the Audio Output Volume
NOTE: This function is only available when the unit is in lock mode 0.
The audio output volume of each output can be displayed and adjusted through a range of
64 steps (1 dB per step, 0% through 100%). The audio output volume can be adjusted from the front panel, through RS-232 or RS-422, or through Ethernet.
NOTE: See the SIS tables in
SIS Configuration and Control on page 34 for
adjustment methods using SIS commands.
Using the Front Panel
1. Press and release the Esc button to clear all pending changes. The button flashes green once.
2. Select the audio plane to be viewed or adjusted. The button lights red or amber.
3. Press and hold any I/O button until the audio plane button flashes red (approximately
2 seconds), and then release the button. All I/O buttons extinguish.
4. Press and release a desired output button. The button lights green. The output audio volume (relative volume) is indicated by the number of lit input buttons. All buttons lit indicates no (zero) attenuation.
5. Press and release the Esc (>) and View (<) buttons to increase or decrease the output
audio volume (see the Audio Output Volume Lighting Table
on page 30 for settings).
6. If desired, select additional outputs by pressing their output buttons.
7. Press and release the Enter button (or wait 30 seconds) to exit the audio display and adjustment mode. The audio plane button extinguishes.
Step 4 – Press the button for the output needing the audio volume adusted (here 3).
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
The selected output button lights green.
The current audio volume is indicated by the lit and flashing input buttons.
Here input buttons 1-16 lit green indicate an output volume of 100% (0 dB attentuation).
Step 5 – Press and hold View to decrease or Esc to increase audio level (here View).
C O N T R O L
ENTER PRESET VIEW ESC
INPUTS
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
OUTPUTS
The selected output button remains lit. Inputs light, flash, or go out as the volume changes.
Here the volume is decreased to 65.5%. Inputs 1-10 are lit green, and 11 is flashing slowly.
Additional outputs can be adjusted by repeating steps 4 and 5.
Step 6 – Press Enter to leave the output audio volume adjustment mode.
All buttons go out.
Figure 26. Adjusting the Output Volume — an Example (Steps 4 through 6)
SMX System MultiMatrix Switcher • Operation 29
NOTE: There is only one audio volume setting per output on any specific plane.
The audio volume is shared by the left and right audio outputs. The audio volume is stored in non-volatile memory. When power is removed and restored, the audio volume settings are retained.
If the audio is set to “follow-all,” upon initial selection (step 2) the I/O plane and associated input and output buttons light amber. When an input or output button is held for 2 seconds (step 3), the I/O plane button flashes red.
62.5
61.0
59.5
58.0
56.5
55.0
53.5
73.0
71.5
70.0
68.5
67.0
65.5
64.0
92.5
91.0
89.5
88.0
86.5
85.0
83.5
100
98.5
97.0
95.5
94.0
82.0
80.5
79.0
77.5
76.0
74.5
25
26
27
28
29
30
31
18
19
20
21
22
23
24
8
9
10
11
5
6
7
0
1
2
3
4
15
16
17
12
13
14
Volume
% dB
Attenuation
Buttons
Lit or
Flashing
Audio Output Volume Adjustment Lighting
SIS command Volume
% dB
Attenuation
16
16 flash slowly flash slowly
15
15 flash slowly flash slowly
14
14 flash slowly flash slowly
13
13 flash slowly flash slowly
12
12 plane*out# *64V
63
62
61
60
56
55
54
53
59
58
57
49
48
47
52
51
50 flash slowly flash slowly
11
11 flash slowly flash slowly
10
46
45
44
43
42
41
40
10 flash slowly flash slowly
9
39
38
37
36
9 flash slowly
35
34 flash slowly plane*out# *33V
14.5
13.0
11.5
10.0
8.5
7.0
5.5
0
25.0
23.5
22.0
20.5
19.0
17.5
16.0
44.5
43.0
41.5
40.0
38.5
37.0
35.5
52.0
50.5
49.0
47.5
46.0
34.0
32.5
31.0
29.5
28.0
26.5
57
58
59
60
61
62
63
76
50
51
52
53
54
55
56
40
41
42
43
37
38
39
32
33
34
35
36
47
48
49
44
45
46
Buttons
Lit or
Flashing
SIS command
8
8 flash slowly flash slowly
7
7 flash slowly flash slowly
6
6 flash slowly flash slowly
5
5 flash slowly flash slowly
4
4 flash slowly flash slowly
3
3 flash slowly flash slowly
2
14
13
12
11
10
9
8
2 flash slowly flash slowly
1
1 flash slowly
7
6
5
4
3
2 flash slowly plane*out# *1V not lit 0 plane*out# *32V
31
30
29
28
24
23
22
21
27
26
25
17
16
15
20
19
18
SMX System MultiMatrix Switcher • Operation 30
Using Reset Levels
The SMX can be returned to default settings by choosing certain reset modes. This can be
done via the front panel or the recessed Reset button on the rear panel (see c on page 8
).
Using the Front Panel
The front panel reset is identical to the E
ZXXX
} SIS command (see the
SIS command on page 51). This clears all ties, presets, and mutes; resets all
RGB delay to 0 seconds; resets all input audio levels to unity gain (0 dB); and sets all output volume levels to 100% (0 dB of attenuation).
NOTES:
• This system reset does not reset the Internet protocol (IP) settings or replace user-installed firmware.
• To save settings, use the SMX Control Program and the File > Save MATRIX settings as...
command (see Save MATRIX settings as...
To initiate the reset, perform the following:
1. If necessary, disconnect the power.
2. Press and hold the View and Esc buttons while reapplying AC power to the SMX.
C O N T R O L
ENTER PRESET VIEW ESC
Power
Figure 27. Front Panel System Reset
3. Continue to hold the View and Esc buttons until the SMX properly powers up (see
on page 16) and then release the buttons.
Using the Rear Panel
The recessed reset button on the rear panel initiates four levels of resets (numbered 1, 3, 4, and 5). Use a pointed stylus or Extron Tweeker to press it and select a reset level (see the
on page 32 for the modes). If the reset button is continuously held down, the I/O light blinks every 3 seconds as the next reset level is reached, corresponding to modes 3, 4, and 5. Use mode 1 if compatibility issues arise with user-loaded firmware.
ATTENTION: After a mode 1 reset is performed, update the firmware to the latest version. Do no operate the SMX with the firmware version that results from the mode 1 reset. To use the factory default firmware, upload that version again.
If mode 1 is selected by mistake, cycle power to the SMX to return to the firmware version that was running before the reset. Use the 0Q
SIS command on page 45 to confirm that
the factory default firmware is no longer running (look for the asterisk [*] following the version number).
• Use mode 3 to restart the communication and control events.
• Use mode 4 to reset most IP protocols to their default settings.
• Use mode 5 to restore the switcher to the default conditions.
SMX System MultiMatrix Switcher • Operation 31
Mode 1
Press and hold the Reset button.
1
2
Apply Power
Release the Reset button.
Modes 3, 4, and 5
Reset LED flashes once,
twice, or three times.
Release, then immediately press and release again. Reset
LED flashes in confirmation.
Press and hold for
3, 6, or 9 seconds.
Figure 28. Resetting the SMX
ATTENTION: Review the reset modes carefully. Using the wrong reset mode may result in unintended loss of flash memory programming, port reassignment, or processor reboot.
NOTE: The reset modes listed in the table below close all open IP and Telnet connections and all sockets. Each mode is a separate function, not a continuation from mode 1 to mode 5.
SMX Series MultiMatrix Switcher Reset Mode Summary
Mode and Activation Result
1. Hold down the recessed Reset button while applying power to the SMX.
The SMX reverts to the factory default
firmware. Event scripting does not start if the
SMX is powered on in this mode. All user files and settings (drivers, adjustments, IP settings, and so on) are maintained.
NOTE: After a mode 1 reset is performed, update the SMX firmware to the latest version. Do not operate the firmware version that results from this mode reset.
If you want to use the factory default firmware, upload that version again (see
or
uploading firmware).
3. Hold down the Reset button for about
3 seconds until the Power LED flashes once, then release and press Reset momentarily (less than 1 second).
NOTE: If you do not want to update firmware, or if you performed a mode 1 reset by mistake, cycle power to the SMX to return to the firmware version that was running prior to the mode 1 reset. Use the 0Q
on page 45 to confirm that the factory default firmware is no longer running (look for asterisks following the version number).
This mode turns events on or off.
NOTE: Nothing happens if the momentary press does not occur within 1 second.
4. Hold down the reset button for about
6 seconds until the Power LED flashes twice (once at 3 seconds and again at 6 seconds). Then release and press Reset momentarily (for less than 1 second).
NOTE: Nothing happens if the momentary press does not occur within 1 second.
5. Hold down the Reset button for about
9 seconds until the Power LED flashes three times (once at 3 seconds, again at
6 seconds, and then at 9 seconds). Then release and press Reset momentarily (for less than 1 second) within 1 second.
This Mode:
• Enables ARP capability.
• Sets the IP address back to factory default
(192.168.254.254).
• Sets the subnet back to factory default.
• Sets the default gateway address to factory default.
• Sets port mapping back to factory default.
• Turns DHCP off.
• Turns events off.
This mode performs a complete reset to factory defaults (except the firmware).
• Does everything mode 4 does.
• Removes button or touchpanel configurations.
• Resets all IP options.
• Removes scheduling settings.
• Removes all files from the SMX.
Purpose/Notes
This mode reverts to the factory default firmware version if incompatibility issues arise with userloaded firmware.
NOTE: User-defined web pages may not work correctly if using an earlier firmware version.
This mode is useful for troubleshooting.
This mode enables you to set IP address information using ARP and the MAC address.
This mode is useful if you want to start over with configuration and uploading, and also to replace events.
SMX System MultiMatrix Switcher • Operation 32
Troubleshooting
This section gives recommendations for general checks and actions for problems operating the SMX.
1. Ensure that all devices are plugged in and powered on. The SMX is receiving power if one of the front panel power supply LEDs is lit green.
2. Check to see if one or more outputs are muted.
3. Ensure that an active input is selected for output on the SMX.
4. Ensure that the proper signal format is supplied.
5. Check the cabling and make corrections as necessary.
6.
Call the Extron S3 Sales and Technical Support Hotline if necessary (see the rear cover
for the contact phone numbers in your region of the world).
SMX System MultiMatrix Switcher • Operation 33
SIS Configuration and Control
The SMX can be configured and operated using the Extron Simple Instruction Set (SIS) of commands. SIS commands can be run from a PC connected to either of the SMX serial ports or the Ethernet port. Use the DataViewer utility or a control system to make serial control the SMX possible.
This section describes the SIS command method of communication and control. Topics that are covered, includes:
•
•
•
•
Using the Command and Response Table for SIS Commands
•
Using the Command and Response Table for IP SIS Commands
RS-232 or RS-422 Link
The SMX has two ports that can be used for serial control. The default protocols for both
serial ports: 9600 baud, 1 stop bit, no parity, no flow control, 8-bit (see b on page 7
, d on
for connection details).
Ethernet (LAN) Port
The Ethernet connection makes SIS control of the SMX possible using a computer connected to the same LAN or WAN. The SIS commands and behavior of the unit are
identical whether it is communicating via Ethernet, RS-232 or RS-422 (see page 7
for details of host device connection through the RS-232 or Ethernet ports).
Ethernet Cable
The Ethernet cable can be terminated as a straight-through cable or a crossover cable and
must be properly terminated for your application (see Ethernet Control on page 106).
Default IP Addresses
To access the SMX via the Ethernet port, you need the Extron IP address, and may need the subnet mask and the gateway address. If the IP address has been changed to an address comprised of words and characters, the actual numeric IP address can be
determined using the ping (CMP) utility (see Ethernet Control on page 106). The factory-
specified defaults are:
IP address: 192.168.254.254, subnet mask: 255.255.0.0, gateway address: 0.0.0.0
SMX System MultiMatrix Switcher • SIS Configuration and Control 34
Establishing an Ethernet Connection
Establish a network connection to the SMX as follows:
1. Open a TCP socket to port 23 using the SMX IP address.
NOTE: If the local system administrators have not changed the value, the factory-specificed default, 192.168.254.254, is the correct value for this field.
The SMX responds with a copyright message including the date, the name of the product, firmware version, part number, and the current date/time (see
on page 36).
NOTES:
• If the SMX is not password-protected, the device is ready to accept SIS commands immediately after it sends the copyright message.
• If the SMX is password-protected, a Password prompt appears below the copyright message.
2. If the SMX is password-protected, enter the appropriate administrator or user password.
3. If the password is accepted, the SMX responds with Login User or Login
Administrator .
4. If the password is not accepted, the Password prompt reappears.
Connection Timeouts
The Ethernet link times out after a designated period of no communication. By default, this timeout value is set at 5 minutes but the value can be changed (see the
IP port timeout command on page 58).
NOTE: Extron recommends leaving the default timeout at five minutes and periodically issuing the Query ( Q ) command to keep the connection active. If there are long idle periods, Extron recommends disconnecting the socket and reopening the connection when another command must be sent.
Number of Connections
An SMX can have up to 200 simultaneous TCP connections, including all http sockets and Telnet connections. When the connection limit is reached, the SMX accepts no new connections until some have been closed. No error message or indication is given that the connection limit has been reached. To maximize performance of an IP Link device, the number of connections should stay low and unnecessary open sockets should be closed.
Using Verbose Mode
Telnet connections to the SMX can be used to monitor changes that occur on the switcher, such as front panel operations and SIS commands from other Telnet sockets or a serial port. For a Telnet session to receive change notices from the SMX, the Telnet session must be in verbose mode 1 or 3 (see the
command on page 57).
SMX System MultiMatrix Switcher • SIS Configuration and Control 35
SIS Programming Guide
Host-to-SMX and SMX-to-Host Communications
SIS commands consist of one or more characters per field. No special characters are required to begin or end a command sequence. When the SMX determines that a command is valid, it executes the command and sends a response to the host device. All responses from the switcher to the host end with a carriage return and a line feed (CR/
LF = ]), which signals the end of the response character string. A string is one or more characters.
Switcher-Initiated Messages
When a local event such as a front panel operation occurs, the switcher responds by sending a message to the host. The switcher-initated messages are listed below.
With an RS-232 or RS-422 connection to a computer (upon power up):
(c) Copyright 2009, Extron Electronics SMX, Vx.xx, 60-XXX-01 ]
Reconfig ]
With an Ethernet connection:
(c) Copyright 2009, Extron Electronics SMX, Vx.xx, 60-XXX-01 ]
Ddd, DD MMM YYYY HH:MM:SS (day, date time as in Tue, 14 Apr 2009 14:43:17 )
The SMX initiates the copyright message when powered on or when connection via Internet
Protocol (IP) is established. Vx.xx is the firmware version number.
] Password:
The SMX initiates the password message immediately after the copyright message when the controlling system is connected using TCP/IP or Telnet and the SMX is password protected. The SMX requires an administrator or user level password before performing the commands entered.
Password prompt is re-displayed if an incorrect password is entered.
] Login Administrator ] and ] Login User ]
The SMX initiates the login message when a correct administrator or user password has been entered. If the user and administrator passwords are the same, the switcher defaults to administrator privileges.
Qik ]
The SMX initiates the Qik message after front panel switching.
Rprnn ]
The SMX initiates the Rpr message when a memory preset has been recalled from the front panel. “ nn ” is the preset number.
Sprnn ]
The SMX initiates the Spr message when a memory preset has been saved from the front panel. “ nn ” is the preset number.
Reconfig ]
The SMX sends the Reconfig message whenever power is cycled, the plane address is changed, or the output board is installed or uninstalled.
NOTE: The response given is seen via an RS-232 or RS-422 connection only.
ppInnn Audxx ]
The SMX initiates the Aud message when a front panel input audio level change has occurred. “ pp ” is the plane address, “ nn ” is the output number, and “ xx ” is the dB level.
SMX System MultiMatrix Switcher • SIS Configuration and Control 36
ppOutnn Volxx ]
The SMX initiates the Vol message when a front panel output audio volume change has occurred. “ pp ” is the plane address, “ nn ” is the output number, and “ xx ” is the volume level.
ppVmtnn*x ]
The SMX initiates the Vmt message when a video output mute is toggled on or off from the front panel. “ pp ” is the plane address, “ nn ” is the output number, and “ x ” is the mute status:
1 = on, 0 = off.
ppAmtnn*x ]
The SMX initiates the Amt message when an audio output mute is toggled on or off from the front panel. “ pp ” is the plane address, “ nn ” is the output number, and “ x ” is the mute status:
1 = on, 0 = off.
Exen ]
The SMX initiates the Exe message when executive mode is toggled on or off from the front panel. “ n ” is the executive mode status: 1 = on, 0 = off.
Switcher Error Responses
When the SMX receives an SIS command and determines that it is valid, it performs the command and sends a response to the host device. If the command is invalid or contains invalid parameters, the SMX returns an error response to the host. The error response codes are:
E01 — Invalid input channel number (out of range)
E10 — Invalid command
E11 — Invalid preset number
E12 — Invalid output number/port number
E13 — Invalid parameter (out of range)
E14 — Command not available for this configuration
E17 — Timeout (only caused by direct write of global presets)
E22 — Busy
E24
E25
E26
E27
E28
— Privilege violation (Ethernet and Extron software only)
— Device not present
— Maximum number of connections exceeded
— Invalid event number
— Bad filename/File not found
Using the Command and Response Table for SIS Commands
The Command and Response Table begins on page 42. Lowercase letters are
acceptable in the command field except where indicated. Figure 29 shows the hexadecimal equivalent of ASCII characters used in the command and response tables.
ASCII to Hex Conversion Table
Space
•
Figure 29. ASC II to Hexadecimal Conversion
Symbols are used throughout the table to represent variables in the command and response fields. Command and response examples are shown throughout the table.
SMX System MultiMatrix Switcher • SIS Configuration and Control 37
Symbol Definitions
] = Carriage return and line feed
¦
or
}
= Carriage return with no line feed
E or
W
• = Space
= Escape key
NOTE: Input and output numbers in commands may be entered as either 1, 2, or
3-digit numbers. All input and output numbers are reported as 2-digit numbers in the response (for example, 03 for input 3).
X!
X@
= Input number
= Input number for ties
X# = Output number
X$ = Numeric dB value
X% = Audio gain
X^
X&
X*
X(
= Audio attenuation
= Volume adjustment range
= Fiber optic transceiver module
= On or Off status
Emulation, muting, power supply, DHCP authorization, or input connection status
01 – < maximum number of inputs >
01 – < maximum number of inputs >
00 = untied
01 – < maximum number of outputs >
-18 – +24 (45 steps of gain attenuation)
0 – 24 (measured in dB)
1 – 18 (measured in dB)
0 – 64 (0% – 100% in 1 dB steps except from 1 to 0 which is in 0.34 dB steps)
0 = no module installed
1 = disabled front panel
2 = enabled (basic only)
0 = off or disabled
1 = on or enabled
NOTE: If the source requires HDCP authentication, ensure that HDCP authorization is set to On (the default).
X1)
X1!
X1#
X1$
X1%
= Output rate (nnnn.nn)
= Global or plane preset number
= Delay
= Video/Audio mute
= Sync frequency
---- = bypass mode
0000 = no connection (rate mismatch) nnnn = actual rate
0 = no mute
1 = video
2 = audio
3 = video and audio
0 – 10 (0 – 5 seconds in 0.5 second increments)
0 = no mute
1 = video
2 = audio
3 = video and audio xxx.xx
(in Hz or kHz)
SMX System MultiMatrix Switcher • SIS Configuration and Control 38
X1^
X1&
X1* = Reclocker rates for SDI/HD-SDI boards
X1( = Signal status
X2)
X2!
X2@
= HDCP compliance
= Executive mode
= Output connection status
= Version number
= Plane addresses
X2$ = Voltage
X2% = Temperature
X2^ = Fan speed
X2( = Create virtual plane address
X3) = Slot number
0 = no source connected
1 = source is HDCP compliant
2 = source is not HDCP compliant
0 = enable (basic and admin)
1 = disabled front panel
2 = enabled (basic only)
00 = auto detect (default)
01 = bypass reclocker
0 = no signal at the input
1 = signal at the input (H)
2 = signal at the input (V)
3 = signal at the input (HV/receive link presence for fiber boards)
0 = no active connection on A or B
1 = first (A) port connected and second
(B) port not connected
2 = first (A) port not connected and
second (B) port connected
3 = active connection on both A and B
x.xx.xxxx (the first 3 numbers is the version number and the last 4 is the build number)
00 – 15 = for 16 planes
90 – 99 = for virtual planes (10 planes)
Positive or negative voltage magnitude
In Degrees Fahrenheit
In RPM
90 – 99 = 10 planes
1 – 4 for 2U units
1 – 6 for 3U units
1 – 8 for 4U units
1 – 10 for 5U units
00 = e-mail F & P
1 – 10 = e-mail I
SMX System MultiMatrix Switcher • SIS Configuration and Control 39
X3!
(X)
B
C
D
E
F
G
J
K
H
I
L
M
= Slot information
Board Type
Video
S-video
S-video
Wideband
S-video DIN
VGA
VGA
Audio analog
SDI/HDSDI
Sync
DVI
DVI
XYZ
X = board type (B – Y)
YZ = board size (00 – 15)
T
U
V
W
X
Y
Q
R
S
(X) Board Type
N DVI Pro
O
P
HDMI
FOMX 1616
FOMX 88
Reserved
Reserved
Reserved
USB
Reserved
DVI (2 data blocks)
No board installed
DVI (2 data blocks)
(YZ) Reference # Board Size
07
06
05
04
15
09
08
00
16x16
8x4x2
8x8x2
8x8
8x4
4x8
4x4
No board installed or slot covered by multi slot board
Note
For S-video BNC
For sync and S-video
Refer to next slot for size of board.
X3@ = EDID reference file for DDC data
X3# = Primary power supply
X3$ = Secondary (redundant) power supply
15 = default (1024x768 at 60 Hz) for DVI
32 = default (720p) for DVI Pro and HDMI
boards
1 – 8 = stored from connected monitors as reference
9 – 36 = fixed factory rates
37 – 40 = user assigned
0 = not installed
1 = OK
2 = failed
0 = not installed
1 = OK
2 = failed
SMX System MultiMatrix Switcher • SIS Configuration and Control 40
EDID Minder Table — DDC Source Selection DVI-Pro and HDMI*
SIS value X3@ Resolution Refresh (Hz) SIS value X3@ Resolution Refresh (Hz) Resolution Refresh (Hz)
1 Output 1 21 1280x1024 60
4
5
2
3
6
7
8
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Output 8
22
23
24
25
26
27
28
1280x1024
1365x768
1365x768
1366x768
1366x768
1400x1050
1600x1200
75
60
75
60
75
60
60
9
10
11
12
13
14
15
16
640x480
640x480
800x600
800x600
852x480
852x480
1024x768
(default) DVI
1024x768
60
75
60
75
60
75
60
75
29
30
31
32
33
34
35
36
480p
576p
720p
720p (default)
DVI-Pro/HDMI
1080i
1080i
1080p
1080p
60
50
50
60
50
60
50
60
480p
2 channel audio
576p
2 channel audio
720p
2 channel audio
720p (default)
2 channel audio
1080p multi channel audio
1080i
2 channel audio
1080p
2 channel audio
1080p
2 channel audio
60
60
50
60
60
60
50
60
17 1024x852 60 37 User assigned
18 1024x852 75 38 User assigned
19
20
1280x768
1280x768
60
75
39
40
User assigned
User assigned
NOTES: * For DVI-Pro and HDMI EDID data, DDC source resolutions and refresh rates differ from DVI Non-pro for SIS X3@ values 29-36.
Multi channel audio consists of:
PCM 2 channel audio (stereo) DTS 8 channel audio
AC-3
PCM
6 channel audio
8 channel audio
AC-3 8 channel audio
2 channel audio is:
PCM 2 channel audio (stereo)
E-AC-3
DTS-HD
MLP
8 channel audio
8 channel audio
8 channel audio
X6) = EDID file data block 128 – 256 bytes of binary data for DVI
(256 bytes depending which DVI board is installed), or 256 bytes for DVI-Pro and
HDMI
NOTE: EDID data block size is dependent on which DVI board is installed.
SMX System MultiMatrix Switcher • SIS Configuration and Control 41
Command and Response Table for SIS Commands
Command
Output Switching by Plane
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
NOTES:
• The & tie command for RGBHV and the % tie command for video can be used interchangeably.
• The ! tie command can be used for switching both video signals and audio signals with the same plane address.
• The & tie command for RGB and the % tie command for video can be used interchangeably.
• The & read tie command for RGB and the % read tie command for video can be used interchangeably.
• Commands can be entered back-to-back in a string with no spaces.
For example: 1*1*1&001*002&001*003*003&001...
The SMX supports 1-, 2-, and 3-digit numeric entries (1*1!, 01*02*02&, or 001*003*003%).
Tie input to an output
(RGBHV)
Tie input to an output (Video)
X2@
X2@
*
*
X@
X@
*
*
X#
X#
&
%
Tie input to an output (Audio)
Tie input to an output (All)
Tie input to all outputs
(RGBHV)
Tie input to all outputs (video)
Tie input to all outputs (audio)
Tie input to all outputs
(audio and video)
Quick Multiple Tie
Make multiple ties
X2@ * X@ * X# $
X2@ * X@ * X# !
X2@ * X@ * &
X2@ * X@ * %
X2@ * X@ * $
X2@ * X@ * !
X2@ Out X# • In X@ • RGB ] Tie input X@ to output X# on plane
X2@ for RGB signals.
X2@ Out X# • In X@ • Vid ]
T ie input X@ to output X# on plane X2@ for Video signals.
X2@ Out X# • In X@ • Aud ] Tie input X@ to output X# on plane X2@ for audio signals.
X2@ Out X# • In X@ • All ] Tie input X@ to output X# on plane X2@ for all signals.
X2@ In X@ • RGB ] Tie input X@ to all outputs on plane
X2@ for RGB signals.
X2@ In X@ • Vid ]
X2@ In X@ • Aud ]
Tie input X@ to all outputs on plane
X2@ for video signals.
Tie input X@ to all outputs on plane
X2@ for audio signals.
X2@ In X@ • All ] Tie input X@ to all outputs on plane
X2@ all signals.
Example:
E +Q X2@ * X@ * X# !
...
X2@ * X@ * X# $ }
E +Q01*3*4!01*3...
*5%01*3*6$ }
Qik ]
Qik ]
Make multiple ties with one command entry.
Tie plane 01 input 3 audio and video signals to outputs 4 (audio and video),
5 (video only), and 6 (audio only).
NOTE: This command activates all I/O switches simultaneously.
NOTES:
X@ = Input number 01 - <maximum number of inputs>
00 = untied
X# = Output number 01 - <maximum number of outputs>
X2@ = Plane number 00 - 15 = plane address
90 - 99 = virtual plane
SMX System MultiMatrix Switcher • SIS Configuration and Control 42
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
View Ties
NOTE: If the view follow-all tie command (!) is used for an output with a break-away tie, the SMX will respond with an error message (E14).
View RGBHV output tie
View video output tie
View audio output tie
X2@
X2@
X2@
*
*
*
X#
X#
X#
&
%
$
X@]
X2@
X2@
Out
X@]
Out
X@]
X#
X#
•
•
In
In
X@
X@
•
•
RGB
Vid
]
]
View RGBHV input tied to output X# on plane X2@ .
Verbose mode 2 or 3
View video input tied to output X# on plane X2@ .
Verbose mode 2 or 3
View audio input tied to output X# on plane X2@ .
Verbose mode 2 or 3 X2@ Out X#• In X@• Aud ]
RGB/Video Mute by Plane
RGB/video mute
RGB/video unmute
Read RGB/video mute
RGB/video mute entire plane
X2@ * X# *1B
X2@ * X# *0B
X2@ * X# B
X2@ *1*B
X2@
X2@
X(]
X2@
Vmt
Vmt
X#
X#
*1
*0
Vmt00*1
]
]
]
Mute RGB/video output
Unmute RGB/video for
Mute RGB/video plane
X# .
X# .
Read RGB/video output X# .
X2@ .
RGB/video unmute entire plane
Audio Mute by Plane
Audio mute
X2@ *0*B X2@ Vmt00*0 ] Unmute RGB/video plane X2@ .
Audio unmute
X2@ * X# *1Z
X2@ * X# *0Z
X2@ Amt X# *1 ]
X2@ Amt X# *0 ]
Mute audio output X# .
Unmute audio for X# .
Read audio mute
Audio mute entire plane
X2@ * X# Z
X2@ *1*Z
X(]
X2@ Amt00*1 ]
Read audio output X# .
Mute all audio on plane X2@ .
Audio unmute entire plane X2@ *0*Z X2@ Amt00*0 ] Unmute all audio on plane X2@ .
View Mute
View output mutes
(entire plane)
EX2@ VM } X1$ 1 X1$ 2 ...
X1$ n ] View output mute for plane X2@ .
Mut X2@ * X1$ 1 X1$ 2 ...
X 1$ n ] Verbose mode 2 or 3
RGB Delay (Triple Action Switching) - for VGA / RGBHV Only
Set RGB Delay (by plane)
Read RGB Delay
EX2@ * X# * X1#
EX2@ * X# D }
D } X2@ Out
X1#]
X# • Dly X1#] Set the RGB Delay of output X#
.
NOTES:
X@ = Input number 01 – <maximum number of inputs>
X# = Output number 01 – < maximum number of outputs >
X( = Mute status 0 = off
1 = on
X1# = RGB delay interval 10 = maximum (in 0.5 second increments)
X1$ = Video/Audio mute status 0 = no mutes
1 = video mute
2 = audio
3 = video and audio mute
X2@ = Plane number 00 - 15 (16 planes)
SMX System MultiMatrix Switcher • SIS Configuration and Control 43
Command ASCII Command
(Host to Switcher)
Global Presets (All Planes)
Save current ties as a global preset
X1!
,
Recall a global preset X1!
.
Response
(Switcher to Host)
Spr
Rpr
X1!]
X1!]
Additional Description
Save the current set of ties as global preset X1!
.
Make the global preset X1!
the current configuration.
NOTE: Attempting to recall an unsaved preset will result in a E11 error code.
Plane Presets
Save current ties as a plane preset
Recall a plane preset
X2@
X2@
*
*
X1!
X1!
*0,
*0.
X2@
X2@
Spr
Rpr
X1!]
X1!]
Save the current set of ties as plane preset X1!
.
Recall plane preset X1!
the current configuration.
as
View Presets (Ties)
NOTE: The G and P commands are case sensitive.
View current video configuration/plane
E G X2@ *0* X# *1VC } X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Vid ] View video configuration.
View current audio configuration/plane
View global presets (video)
View global presets (audio)
View plane presets (video)
View plane presets (audio)
Vgp X2@ *00 • Out X# • X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Vid ] Verbose mode 2 or 3
E G X2@ *0* X# *2VC } X@ 1 • X@ 2 • X@ 3 • X@ 4
...
X@ 16 • Aud ] View audio configuration.
Vgp X2@ *00 • Out X# • X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Aud ] Verbose mode 2 or 3
E G X2@ * X1!
* X# *1VC } X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Vid ] View video configuration.
Vgp X2@ * X1!
• Out X# • X@ 1 • X@ 2 • X@ 3 • X@ 4
... X@ 16 • Vid ] Verbose mode 2 or 3
E G X2@ * X1!
* X# *2VC }
Vgp X2@ * X1!
• Out X# • X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Aud ] Verbose mode 2 or 3
E P X2@ * X1!
* X# *1VC }
X@ 1 • X@ 2 • X@ 3 • X@ 4
... X@ 16 • Aud ] View audio configuration.
X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Vid ] View video configuration.
Vpp X2@ * X1!
• Out X# • X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Vid ] Verbose mode 2 or 3
E P X2@ * X1!
* X# *2VC } X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Aud ] View audio configuration.
Vpp X2@ * X1!
• Out X# • X@ 1 • X@ 2 • X@ 3 • X@ 4 ... X@ 16 • Aud ] Verbose mode 2 or 3
NOTES:
• If a preset is unassigned, then name displayed is [unassigned].
• If a global preset is saved but not yet named, then default name is “Preset
• Viewing global presets show the ties for the selected plane.
X1!
• Viewing plane presets lists only the configuration of that particular plane.
• When viewing outputs, only outputs higher than the one designated display.
, ” ( X1!
= preset number).
Virtual (Multi Plane) Definition
Write virtual plane address
Read Virtual plane address
EX2( , X2@ 1 * X2@ 2 * X2@ n
MP } Mpv X2( , X2@ 1 , X2@ 2 ...
X2@ n ]
EX2( MP } X2@ 1 , X2@ 2 ...
X2@ n ]
Write virtual plane address.
Read virtual plane address.
NOTES:
X@ = Input number 01 - <maximum number of inputs>
X# = Output number 01 - <maximum number of outputs>
X1!
= Preset number 01 - 32 = global presets
1 - 10 = plane presets
X2@ = Plane number 00 - 15 = 16 planes
X2( = Virtual plane number 90 - 99 = 10 planes
SMX System MultiMatrix Switcher • SIS Configuration and Control 44
Command ASCII Command
(Host to Switcher)
Front Panel Lockout (Executive Mode)
Lock front panel
(advanced functions)
Lock front panel
2X
1X
Unlock front panel 0X
View front panel lock X
Response
(Switcher to Host)
Exe2 ]
Exe1 ]
Exe0 ]
X1&]
Additional Description
Enable lock mode 2.
Enable lock mode 1.
Disable lock mode.
Show lock mode status.
NOTE: For full lock mode details, see
Setting the Front Panel Locks (Executive Modes) on page 25.
Information Requests
NOTE: Firmware version/part number/information Primary BME only.
Query firmware version
Example:
Query firmware and build version
Query kernel firmware and build version
Query verbose version information
Q
Q
*Q
**Q
0Q
X2!]
1.14
]
Ver01* X2!]
The firmware version is
1.14.
Verbose mode 2 or 3
X2!]
Bld X2!]
X2!]
Lib X2!]
Verbose mode 2 or 3
Verbose mode 2 or 3
Sum of responses from 2Q-3Q-4Q ]
Ver00* sum of responses from 2Q-3Q-4Q ] verbose response
NOTE: The firmware that is currently running is marked by an asterisk (*). A question mark (?.??) indicates that only factory firmware is loaded. A caret (^) indicates the firmware that should be running, but a Mode 1 reset was executed and the default factory version is loaded. An exclamation point (!) indicates corrupted firmware.
Example 0Q
Response: Description * indicates the version running Upload date and time
| | |
1.23 - 0.14(0.20-SMX Series - Wed, 04 Jan 2006 23:11:29 GMT) - 1.00*(0.24-SMX Series - Thu, 20 Apr 2007 20:02:35 GMT)
Ethernet protocol SMX firmware version Updated firmware version firmware
Query firmware version
Query bootstrap version
Query factory firmware version
1Q
2Q
3Q
X2!]
Ver01* X2!] Verbose mode 2 or 3
X2!]
Ver02* X2!] Verbose mode 2 or 3
X2!] (plus web ver.-desc-upload date/time)
Query updated firmware version
Ver03* X2!] (plus ver.-desc-upload date/time) ]
4Q
Verbose mode 2 or 3
X2!] (plus web ver.-desc-upload date/time) ]
Ver04* X2!] (plus web ver.-desc-upload date/time) ] Verbose mode 2 or 3
NOTE: The 3Q and 4Q responses indicate the web version, a brief description (model used on), and the date the last version was uploaded. For example, a typical 4Q response is; [1.14*(1.77-SMX Series -Wed, 01 Apr 2011
18:35:43 GMT)], indicating loaded firmware version is 1.14, web version is 1.77 for the SMX, uploaded Wednesday,
April 1st 2011 at 6:35 pm GMT).
NOTES:
X1& = Lockout mode status: 0 = disabled, 1 = enabled, 2 = enabled (basic only)
X2!
= Version number x.xx
SMX System MultiMatrix Switcher • SIS Configuration and Control 45
Command ASCII Command
(Host to switcher)
Query system status S
Query specific system status nS
Example: S
Response
(Switcher to host)
Additional Description
X2$•X2$•X2$•X2%•X2^•X2^•X3#•X3$]
X2$ or X2% or X2^ or X3#]
Stsn* X2$ or X2% or X2^ or X3#] Verbose mode 2 or 3
Sts0* 3.31 4.98 24.22 +100.40 03305 03308 1 0 ]
3.31 and 4.98 are power supply voltages; 24.22 is fan voltage,
100.40 (degrees F) is the temperature, 03305 is fan 1 rpm, 03308 is fan 2 rpm, 1 is primary power supply (OK).
V
V
X@ 0 X X# 0 A X@ 0 X X# 0 • ...
V X@ 15 X X# 15 A X@ 15 X X# 15 • ...
X@ 25 X X# 25 A X@ 25 X X# 25 ]
Query switcher information
(general) per plane (16 actual and 10 virtual) plus board configuration
Example:
I
V16x16A16x16 • V--X--A--X-• V--X--A--X-• V--X--A-
-X-• ...
...
• V--X--A--X-]
NOTE: The I response gives 26 parameters, the first 16 (V_x_A_x_) is plane information (planes 0-15), and the next are virtual planes 1-10 (90-99).
Query model name 1I
Example:
Query model description
Example:
Query system-memory usage 3I
Query user-memory usage
Query plane address per slot
Example:
2I
4I
E STAT
Stat*
}
Switcher description (short) ]
Inf01*Switcher description (short) ] Verbose mode 2 or 3
Inf01*SMX ]
Switcher description (long) ]
Inf02*Switcher description (long) ] Verbose mode 2 or 3
Inf02*System Multi Matrix ]
# of Bytes used out of # KBytes ]
Inf03*# of Bytes used out of # KBytes Verbose mode 2 or 3
# of Bytes used out of # KBytes ]
Inf04*# of Bytes used out of # KBytes Verbose mode 2 or 3
X2@ (slot 1)
•X2@
(slot 2)
• ...
X2@ ( slot 6/8/10) ] Verbose mode 2 and 3
Stat X2@ (slot 1) •X2@ (slot 2) • ...
X2@ (slot 6/8/10) ]
5U frame, 10 slots
Slot 1 2 3 4 5 6 7 8 9 10
00 • 01 • -• 02 • -• -• 03 • -• 03 • 03 ]
Slot 1 00 the board address installed in slot 1 is plane 00
Slot 2 01 the board address installed in slot 2 is plane 01
Slot 3 - - No board installed
NOTES:
X@ = Input number 01 - <maximum number of inputs>
00 = untied
X# = Output number 01 - <maximum number of outputs>
X2@ = Plane number 00 - 15
90 - 99 = virtual plane
X2$ = Voltage + or – voltage
X2% = Temperature
X2^ = Fan speed RPM
X3# = Primary power supply 0 = not installed
1 = OK
2 = failed
X3$ = Secondary (redundant) power supply 0 = not installed
1 = OK
2 = failed
SMX System MultiMatrix Switcher • SIS Configuration and Control 46
I
H
F
G
C
D
(X)
B
E
L
M
J
K
Command ASCII Command
(Host to Switcher)
N
Response
(Switcher to Host)
60-xxx-yy
Additional Description
Query part number and slot information
Example:
*N
*N
60 xxx yy .
X3!
n 1 X3!
n 2 X3!
n 3 ... X3!
n 6/8/10 ]
Pno 60-xxx-yy.
X3!
n 1 X3!
n 2 X3!
n 3 ...
X3!
n 6/8/10 ]
Verbose mode 2 or 3
Pno60-857-01.L04J07G00G00G00G15D00D15C00C15
Where X3!
n x = XYZ; X = type of board (B-T & X), YZ = board size
(00-15) and nx is the number of the slot the board is installed in.
NOTE: Left table gives X value. Right table gives YZ value.
n1 = Slot 1 L04 DVI board (L) 4x4 configuration (04) - 1 slot board
n2 = Slot 2 J07 HD-SDI bard (J) 8x8 configuration (07) - 1 slot board
n3 = Slot 3 G00 Slot 3 is covered by VGA board (G) no board (0)
n4 = Slot 4 G00 Slot 4 is covered by VGA board (G) no board (0)
n5 = Slot 5 G00 Slot 5 is covered by VGA board (G) no board (0)
n6 = Slot 6 G15 VGA board (G) 1616 configuration (15) - 4 slots board
n7 = Slot 7 D00 Slot 7 is covered by S-video BNC board top (D) no board (0)
n8 = Slot 8 D15 S-video BNC top board (D) 1616 configuration (15) - 2 slots (top) of 4
n9 = Slot 9 C00 Slot 9 is covered by S-video BNC board bottom (C) no board (0)
n10 = Slot 10 C15 S-video BNC top board (C) 1616 configuration (15) - 2 slots (bottom) of 4
A slot response can show either no board installed (X00), or the slot is covered by a multi slot board as shown in the example above; slots 3, 4, and 5, (G00) are covered by the 1616 VGA board in slot 6.
Board Type
Composite BNC
S-video BNC O
S-video BNC 1616 P
Wideband
(X)
N
Q
S-video DIN
VGA 1616
VGA 88/84
Audio analog
T
U
R
S
SDI/HDSDI
Sync
DVI
DVI
X
Y
V
W
Board Type
DVI Pro
HDMI
FOMX 1616
FOMX 88
Reserved
Reserved
Reserved
USB
Reserved
DVI (2 data blocks)
No board installed
DVI (2 data blocks)
08
07
06
05
Reference
# (YZ)
15
09
04
00
Board Size
16x16
8x4x2
8x8x2
8x8
8x4
4x8
4x4
No board installed or slot covered by multi slot board
Note
For S-video BNC
For sync and S-video
Refer to next slot for size of board
NOTE:
X3!
= board type and board size (XYZ) X = Type of board (B - Y)
YZ = Board size (00 - 15)
SMX System MultiMatrix Switcher • SIS Configuration and Control 47
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
EDID Commands by Slots
Assign EDID data to input E A X3) * X!
* X3@ EDID } X3) EdidA X!
* X3@ ]
Assign EDID data to all inputs
Save output 1 EDID data
View EDID data assignment
E A X3) * X3@ *EDID } X3) EdidA00* X3@]
E S X3) * X3@ EDID }
E A X3) * X!
EDID }
X3) EdidS X3@]
X3@]
X3) EdidA X!
* X3@]
Export EDID file data
Import EDID file data
E E X3) * X3@ EDID } X6)]
X3) EdidE X3@ * X6)]
E I X3) * X3@ EDID }X6) X3) EdidI X3@]
Additional Description
Applies only when X3@ = 37 to 40.
Verbose mode 2 or 3
Verbose mode 2 or 3
X3@ = 37 to 40
SIS Value
1
X3@
EDID Minder Table — DDC Source Selection
Resolution
Output 1
Refresh (Hz)
SIS Value
21
X3@ Resolution
1280x1024
7
8
5
6
9
2
3
4
Output 2
Output 3
Output 4
Output 5
Output 6
Output 7
Output 8
640x480 60
25
26
27
28
29
22
23
24
1280x1024
1365x768
1365x768
1366x768
1366x768
1400x1050
1600x1200
480p
Refresh (Hz)
60
75
60
60
60
60
75
60
75
DVI-Pro and HDMI*
Resolution Refresh (Hz)
10
11
12
13
14
15
16
640x480
800x600
800x600
852x480
852x480
1024x768
(default) DVI
1024x768
75
60
75
60
75
60
75
30
31
32
33
34
35
36
576p
720p
720 (default)
DVI-Pro/HDMI
1080i
1080i
1080p
1080p
50
50
60
50
60
50
60
480p
2 ch audio
576p
2 ch audio
720p
2 ch audio
720p (default)
2 ch audio
1080i
Multi ch audio
1080i
2 ch audio
1080p
2 ch audio
1080p
2 ch audio
60
60
50
60
60
60
50
60
17
18
19
20
1024x852
1024x852
1280x768
1280x768
60
75
60
75
37
38
39
40
User assigned
User assigned
User assigned
User assigned
NOTES: *For DVI-Pro and HDMI EDID data, DDC source resolutions and refresh rates differ from DVI Non-pro for SIS values 29-36 (see
for DVI-Pro and HDMI channel definitions).
X3@
X!
= Input number 01 - <maximum number of inputs>
X3) = Slot address 01 - 10
X3@ = EDID reference file for DDC data 15 (DVI) or 32 (DVI-Pro) is default
0 = automatic
1 - 8 = stored from connected EDID monitors (reference)
9 - 36 = factory fixed rates
37 - 40 = user definable
X6) = EDID file data block 128 or 256 bytes of binary data for DVI (depending on which
DVI board is installed or 256 bytes for DVI-Pro and HDMI
SMX System MultiMatrix Switcher • SIS Configuration and Control 48
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Commands Specific to SMX SDI/HD-SDI Boards
Output Re-clocking Per Slot
Set output reclocker per slot X3) * X# * X1* =
Read reclocker X3) * X# =
List DSVP (Digital Sync Validation Processing)
DSVP for VGA and RGBHV
Rte X3) * X# * X1* ]
X1*]
List individual sync (DVSP) X3) * X!
LS X1% H , X1% V ]
X3) FRQ X!
1 , X1% H , X1% V ]
NOTE: Unit responds 0000.00, 0000.00 if no connection or an error is found.
Additional Description
Listed as Horizontal, Vertical.
Verbose mode 2 or 3
List all input sync (DVSP) X3) *0LS X1( 1 X1( 2 ... X1( n ]
X3) FRQ00* X1( 1 X1( 2 ... X1( n ] Verbose mode 2 or 3
DSVP (Signal Present) for Composite/S-video/DVI/DVI-Pro/HDMI Boards
List all input sync (DVSP) X3) *0LS X1( 1 X1( 2 ... X1( n ]
X3) FRQ0* X1( 1 X1( 2 ... X1( n ] Verbose mode 2 or 3
NOTE: List individual signal present per slot is not available on this board. Unit responds with error E14.
DSVP (Signal Present and Rate/Reclocker) for SDI/HD-SDI Boards
List individual sync (DVSP)/slot X3) * X# LS X1)]
X3) FRQ X# * X1)]
NOTE: Unit responds 0000 if no connection, no ties, or an error is found.
Verbose mode 2 or 3
List all sync (DVSP)/slot X3) *0LS X1( 1 X1( 2 ...
X1( n ]
X3) FRQ0* X1( 1 X1( 2 ...
X1( n ] Verbose mode 2 or 3
DSVP (Link Present) for Fiber Optic Boards
List all input (DVSP) X3) *0LS X1( 1 X1( 2 ...
X1( n ]
X3) FRQ0* X1( 1 X1( 2 ... X1( n ] Verbose mode 2 or 3
NOTE: List individual signal present per slot is not available on this board. Unit responds with error E14.
Fiber Optic Board Status
View Fiber transceiver module installed
0* X3) I X* 1 X* 2 ...
X* n ]
Inf X3) * X* 1 X* 2 ...
X* n ] Verbose mode 2 or 3
NOTES:
X!
= Input number 01 - <maximum number of inputs>
X# = Output Number 01 - <maximum number of outputs>
X* = Fiber optic transceiver module 0 = no module installed
1 = multimode module
2 = singlemode module
X1) = Output rate ---- = bypass mode
0000 = no connection (rate mismatch)
nnnn = actual rate
X1% = Sync frequency xxx.xx in Hz or kHz
X1* = Reclocker rates for SDI/HD-SDI board 00 = autodetect (default)
01 = bypass the reclocker
X1( = Signal status where 0 = no signal at input
1 = signal at input (H sync)
2 = signal at input (V sync)
3 = signal at input (H and V sync) or receive link presence
X3) = Slot address 01 - 10
SMX System MultiMatrix Switcher • SIS Configuration and Control 49
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
HDCP Detect
View input HDCP E I X3) * X!
HDCP } X1^]
X3) HdcpI X!
* X1^]
View output HDCP
View all inputs HDCP
E O X3) * X# HDCP } X1^]
X3) HdcpO X# * X1^]
E I X3) *HDCP } X1^ 1 X1^ 2 X1^ 3 ...
X1^ n ]
X3) HdcpI00* X1^ 1 X1^ 2 ... X1^ n ]
View all outputs HDCP E O X3) *HDCP } X1^ 1 X1^ 2 ... X1^ n ]
X3) HdcpO00* X1^ 1 X1^ 2 ...
X1^ n ]
Setting Input Audio Gain and Attenuation by Plane
Additional Description
View HDCP of input
Verbose mode 2 or 3
X!
.
View HDCP of output X# .
Verbose mode 2 or 3
View HDCP of all inputs in slot
Verbose mode 2 or 3
View HDCP of all inputs in slot
Verbose mode 2 or 3
NOTE: The G and g commands are case sensitive.
Gain (+dB) X2@ * X!
* X% G
Attenuation X2@ * X!
* X^ g
Increment X2@ * X!
+G
Decrement X2@ * X!
–G
Setting Output Audio Volume by Plane
Increment X2@ * X# +V
Decrement X2@ * X# –V
Output level X2@ * X# * X& V
View Audio Levels
Audio gain for input
Audio volume for output
X2@ * X!
G
X2@ * X# V
Names
X2@
X2@
X2@
X2@
X2@
X2@
X2@
In
In
In
In
X$]
X&]
X!•
X!•
X!•
X!•
Out
Out
Out
Aud
Aud
Aud
Aud
X#•
X#•
X#•
X$]
X$]
X$]
X$]
Vol
Vol
Vol
X&]
X&]
X&]
NOTE: Names may have up to 12 characters, but the following characters are invalid or not recommended for names: - , ' [ ] { } ; | \ ?
X3) .
X3) .
Write global preset name
Example:
Read global preset
Example:
Write plane preset
Read plane preset
EX1!
,nameNG } Nmg X1!
,name ]
E 1,Security1NG } Nmg01,Security1 ]
EX1!
E 2NG
NG
}
} name ]
Security1 ]
EX2@ * X1!
,nameNG } X2@ Nmg X1!
,name ]
EX2@ * X1!
NG } name ]
Assign name to preset X1!
.
Name global preset 1 "Security1."
NOTES:
X!
= Input number 01 - < maximum number of inputs >
X# = Output number 01 - < maximum number of outputs >
X$ = Numeric dB value –18 though +24 dB (43 steps of gain or attenuation)
X% = Audio gain 0 dB through 24 dB)
X& = Volume adjustment 0 - 64 (default = 64 [0 dB])
X1!
= Global/plane preset 0 = current ties for system in view
1 - 32 max global, 1 - 10 max plane
X1^ = HDCP compliance 0 = no source/output connected
1 = source/output connected is HDCP compliant
2 = Source/output connected is not HDCP compliant
X2@ = Plane address 00 to 15 (16 planes)
X3) = Slot address 1 - 10
SMX System MultiMatrix Switcher • SIS Configuration and Control 50
Command
Write input name (per plane)
Read input name
Write output name (per plane)
Read output name
ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
EX2@ * X!
,nameNI } X2@ Nmi X!
,name ]
EX2@ * X!
NI } name ]
EX2@ * X# ,nameNO } X2@ Nmo X# ,name ]
EX2@ * X# NO } name ]
Additional Description
Assign a name to input X!
.
Assign a name to output X# .
NOTES:
• If a preset (global or plane) is unassigned, its name is displayed [unassigned].
• If a global preset is saved but not named, its default name is Preset X1!
.
• If a plane preset is saved but not named, its default name is Pln X2@• Pre X1!
.
• If you attempt to name or recall a preset that is not saved, or is unassigned, the unit responds with the error message E11.
• Putting a space in the name field sets the I/O and presets (global & plane) back to default.
Reset to Factory Defaults (Zap Commands)
Reset global presets and names
E ZG }
Reset individual global presets
Reset individual plane presets
EX1!
ZG }
EX2@ * X1!
ZG }
Reset All RGB Delay to 0 seconds
Reset RGB Delay entire plane
E ZD }
Reset all audio gains to 0 dB
Reset audio gains to 0 dB for entire plane
Reset all audio volume to 100%
Reset all audio volume to 100% for entire plane
Unmute RGB/Audio (all mutes)
EX2@ ZD }
E ZA }
EX2@ ZA }
E ZV }
EX2@ ZV }
Unmute RGB/Audio (per plane)
Reset switcher
E ZZ }
EX2@ ZZ }
E ZXXX }
Reset flash memory
Absolute system reset
Reset all device settings and delete files
E
E
E
ZFFF
ZQQQ
ZY }
}
}
Zpg
Zpg
]
X1!]
X2@ Zpg X1!]
Zpd ]
X2@
Zpa
X2@
Zpv
X2@
Zpz
X2@
Zpx
Zpf
Zpq
Zpy
Zpd
]
Zpa
]
Zpv
]
Zpz
]
]
]
]
]
]
]
]
Clear all global presets and their names.
Clear global preset X1!
.
Clear plane preset X1!
.
Reset RGB Delay to zero.
Reset RGB Delay to zero.
Reset all audio gains to zero.
Reset all audio gains to zero.
Reset all volume to 100%.
Reset all volume to 100%.
Clear all ties and presets and reset the SMX to factory defaults.
Reset flash memory (reset user-supplied files).
Reset IP address to
192.168.254.254 and subnet mask to 255.255.0.0.
Reset device and delete all files.
NOTE: E ZY reset excludes IP settings (IP address, subnet mask, gateway address, unit name, DHCP settings and port mapping [Telnet, web, or direct access]) in order to preserve communications with the device. This reset is recommended after a firmware update.
NOTES:
X!
= Input number 01 - <maximum number of inputs>
X# = Output number 01 - <maximum number of outputs>
X1!
= Global or plane preset 1 - 32 = global
1 - 10 = plane
X2@ = Plane address 00 - 15 = 16 planes
90 - 99 = virtual planes (10 planes)
SMX System MultiMatrix Switcher • SIS Configuration and Control 51
Command ASCII Command
(Host to Switcher)
Commands Specific to SMX USB Boards
Port Emulation for Outputs
Response
(Switcher to Host)
Additional Description
Set port emulation for all outputs
Set port emulation for output pairs
E
E
E
E
X 3)
X3)
*
*
X(
X#
*USBC
* X(
}
USBC
X3)
} X3)
UsbcE0*
UsbcE X#
X(
*
]
X( ]
Enable or disable port emulation for all outputs.
Enable or disable port emulation for output X# .
View port emulation status for outputs
View port emulation status for all outputs
E
E
E
E
X3)
X3)
* X# USBC
*USBC }
} X( ]
X3) UsbcE X# * X(] Verbose mode 2 and 3
X( 1 X( 2 X( 3
...
X( n ]
X3) UsbcE* X( 1 X( 2
...
X( n ] Verbose mode 2 and 3
Signal Status
View input signal status
View all input signal status
E
E
I
I
X3)
X3)
* X!
USBC
*USBC }
} X(]
X3) UsbcI X!
* X(] Verbose mode 2 and 3
X( 1 X( 2 X( 3
... X( n ]
X3) UsbcI* X( 1 X( 2 X( 3
... X( n ] Verbose mode 2 and 3
View output signal status E O X3) * X# USBC } X2)]
X3) UsbcO X# * X2)] Verbose mode 2 and 3
View all output signal status E O X3) *USBC } X2)
X3)
1 X2) 2 X2)
UsbcO*
3
X2)
...
1
X2)
X2) 2 n ]
X2) 3
... X2) n ] Verbose mode 2 and 3
Commands Specific to SMX HDMI and DVI Pro Boards
HDCP Status
NOTE: If the source requires HDCP authentication, ensure that HDCP authorization is set to On (the default).
HDCP Authorization On
HDCP Authorization Off
Query HDCP encryption status
E
E
E
E
E
E
X3)
X3)
X3)
*
*
*
X!
X!
X!
*1HDCP
*0HDCP
HDCP }
}
}
X3)
X3)
HdcpE
HdcpE
X(]
X!
X!
*1
*0
]
]
Turn HDCP authorization on for input X!
(default).
Turn HDCP authorization on for input X!
.
View HDCP authorization status for input X!
.
X3) HdcpE X!
* X(]
Verbose mode 2 and 3
NOTES:
X!
= Input number 01 - < maximum number of inputs >
X# = Output number 01 - 04
X( = On or off status 0 = Off or disabled
1 = On or enabled
X2) = Output connection status 0 = No active connection on A or B
1 = 1st (A) port is connected but the 2nd (B) port is not connected
2 = 1st (A) port is not connected but the 2nd (B) port is connected
3 = Active connection on both A and B
X3) = Slot number 01 - 10
0 = Hard coded, representing all outputs
SMX System MultiMatrix Switcher • SIS Configuration and Control 52
Using the Command/Response Table for IP SIS Commands
The Command and Response Table begins on page 42.
Symbol Definitions
X5!
X5@
X5#
X5$
= Specific port number
= GMT offset
= On/Off status
= Unit name
01 – 99
00 = reserved
The port number is represented as two
ASCII characters (for example, port 05 would be represented as 30 35 in hex).
–12.0 - +14.0
Hours and minutes are removed from
GMT.
0 = off or disabled
1 = on or enabled
Text string up to 24 characters (A-Z,
0-9, and "-").
Not case sensitive.
NOTE: The following characters are invalid or not recommended in the name: ~ , @ =
' [ ] { } < > ` " ; : | \ ?
and space
The first character must be an alpha character, the last must not be a hyphen.
X5% = Time and date (set and read)
X5^ = IP or gateway address
MM/DD/YY•HH:MM:SS
MM = month: 01 (January) through 12
(December)
DD = day: 01 through 31
YY = year: 00 through 99
HH = hour: 00 through 23
MM = minutes: 00 through 59
SS = seconds: 00 through 59 nnn.nnn.nnn.nnn
NOTE: Factory default IP/Gateway address: 192.168.254.254
X5& = E-mail domain name Standard name conventions apply; for example, xxx.com.
NOTES:
• The following characters are invalid or not recommended in the name: ~ , @ = '
[ ] { } < > ` " ; : | \ ?
and space
• The @ character is acceptable only as lead-in to the domain name (such as
@extron.com
)
X5* = Hardware (MAC) address
X5( = Default name
X6) = Subnet mask xx-xx-xx-xx-xx-xx
SMX-xx-xx-xx nnn.nnn.nnn.nnn
NOTE: Leading zeros in each of the four fields are optional in setting values and suppressed in returned values.
SMX System MultiMatrix Switcher • SIS Configuration and Control 53
X6#
X6^
X6&
X6*
X6(
X7)
X7#
X7$
= Verbose mode
= Baud rate
= Parity
= Data bits
= Stop bits
= Port type
= Web page priority flag
= Password
0 = clear/none
(default for Telnet connections)
1 = verbose mode (default for RS-232
and RS-422 connections)
2 = tagged responses for queries
3 = verbose mode and tagged for queries
9600 (default), 9200, 38400, 115200
O = odd
E = even
N = none
M = mark
S = space
7 , 8
1 , 2
0 = RS-232 (default)
1 = RS-422
2 = RS-485
0 = internal (default factory reset)
1 = user
12 digits, alphanumeric
User or admin
NOTES:
• The following characters are invalid or not recommended in the name: ~ , @ = '
[ ] { } < > ` " ; : | \ ?
and space
• User password cannot be assigned if no admin password exists (returns error code
E14 ). When admin password is cleared, then user and all security level passwords are deleted.
X7%
X7^
X7&
= Daylight Saving Time
= Event number
= Event data size
0 = Daylight Saving Time off or ignore
1 = Daylight Saving Time on
(USA - April to October)
2 = Daylight Saving Time on
(Europe - March to October)
3 = Daylight Saving Time on
(Brazil - October to March)
0 - 99
Event must be running.
b = bit
B = byte (8 bits)
S = short (16 bits)
L = long (32 bits)
NOTE: The parameter is case sensitive and may be optionally preceded by A (And) or
O (Or) to logically combine with content instead of replacing it.
X7( = Number of bytes to read 1 - 127
X8) = E-mail event number or mailbox 1 - 64
Response is 3 digits with leading zeros.
X8!
= E-mail recipient address
SMX System MultiMatrix Switcher • SIS Configuration and Control 54
X8@
X8#
X8$
X8%
X8&
X8* = The number of seconds before
a timeout on IP connections
X8(
X9)
= E-mail account
= Notification selection 1
= Notification selection 2
= Notify what?
= Default name
= Number of open connections
= Slot address
65 - 72
I = inputs
F = fans
P = power supply
If X8# = I , then X8$
(all inputs, or 1 - 16 )
= 00
If X8# = F , then X8$ = 00
01 (fan 1), or 02 (fan 2)
(both fans), or
If X8# = P , then X8$ = 00 (both power supplies), or 01 (PS 1), or 02 (PS 2)
0 = no response
1 = failed or missing
2 = fixed or restored
3 = both (1 and 2)
4 = suspend
5 = un-suspend
Combination of the model name and the last three pairs of the MAC address; for example, IPL-T-S2-00-02-3D.
1 - 65000 seconds
30 (300 seconds) = default
If no data is received during the timeout period, the Ethernet connection is closed. Each step is 10 seconds.
This is applicable to Ethernet only.
When the unit is connected via
RS-232 or RS-422, only the global timeout commands apply. Response is returned with leading zeros.
0 - 255
00 = F and P
01 - 10 = I
SMX System MultiMatrix Switcher • SIS Configuration and Control 55
Command and Response Table for IP SIS Commands
Command ASCII Command
(Host to Switcher)
Response
(Switcher to Host)
Additional Description
IP Setup Commands
Set unit name
Reset unit name to factory default
Read unit name
Set time and date
EX5$ CN }
E• CN }
E CN }
EX5% CT }
Ipn •X5$]
Ipn •X5(]
X5$] or X5(]
Ipt •X5%] See
X5%
on page 53 for more details.
Read time and date
Set GMT offset
E CT }
EX5@ CZ }
X5%]
Ipz X5@]
NOTE: In the command, the divider between hours and minutes can be either a colon or a period. In the response, the divider is a colon.
Example:
Read GMT offset
Set Daylight Saving Time
Read Daylight Saving Time
Set DHCP on
Set DHCP off
E 8.0CZ
}
E CZ }
EX7% CX }
E CX }
E 1DH }
E 0DH }
Ipz+08:00 ]
X5@]
Ipx X7%]
X7% ]
Idh1 ]
Idh0 ]
NOTE: Setting DHCP from on to off will reset the IP address to factory default (192.168.254.254).
View DHCP mode
Set IP address
Read IP address
Read hardware address
(MAC)
Read # of open connections
E
EX5^
E
E
E
DH
CI
CH
CC
}
CI
}
}
}
}
X5#]
Ipi •X5^]
X5^]
X5*]
Iph •X5*]
X8(]
00-05-A6-xx-xx-xx = MAC address
Verbose mode 2 and 3
0 - 200 = number of open connections
NOTES:
X5@ = GMT offset –12.0 through +14.0 hours and minutes removed from GMT
X5# = DHCP mode status 0 = off or disabled
1 = on or enabled
X5$ = Unit name Text string up to 24 characters (A-Z, 0-9, and "-").
Not case sensitive.
X5% = Time and date (set and read) MM/DD/YY•HH:MM:SS
X5^ = IP/Gateway address nnn.nnn.nnn.nnn, Factory default IP address: 192.168.254.254
X5* = Hardware (MAC address) nn.nn.nn.nn.nn.nn
X5( = Default Name Combination of model name and last 3 pairs of MAC address
(SMX-00-02-3D)
X7% = Daylight Saving Time 0 = Daylight Saving Time off or ignore
1 = Daylight Saving Time on (USA)
2 = Daylight SavingsTime on (Europe)
3 = Daylight Saving Time on (Brazil)
X8( = Number of open connections 0 - 200
SMX System MultiMatrix Switcher • SIS Configuration and Control 56
Command
Set subnet mask
Read subnet mask
Set gateway IP address
Read gateway IP address
Set administrator password
Read administrator password
Reset (clear) administrator password
Set user password
Read user password
Reset (clear) user password
Set verbose mode
ASCII Command
(Host to Switcher)
EX6)
E CS }
EX5^
E CG }
EX7$
E CA
E•
E•
}
CA
EX7$
E CU
CU
EX6#
CS
CG
CA
}
CU
}
}
CV
}
}
}
}
}
Response
(Switcher to Host)
Ips •X6)]
X6)]
Ipg •X5^]
X5^]
Ipa •X7$]
X7$]
Ipa •X7$]
Ipu
X7$]
Ipu
Vrb
•X7$]
•X7$]
X6#]
Additional Description
Enable or disable verbose mode and tagged responses, where additional information is provided in response to a query.
NOTE: The SMX can send out unsolicited information (such as a notice of a change in input or some other setting).
This is a verbose (wordy) relationship between the switcher and a connected device. For a direct RS-232 or RS-422 connection, the SMX is set for verbose mode by default. When the SMX is connected via Ethernet, verbose mode is disabled by default in order to reduce the amount of communication traffic on the network. If you want to use verbose mode with a switcher connected via Ethernet, you must set this mode to On each time you reconnect to the SMX.
View verbose mode E CV } X6#]
12 digits, alphanumeric
Show verbose mode or tagged response status X6#
.
Set mail server IP, unit domain name
E
X5^ , X5& , X7$ , X7$ CM }
Ipm •X5^ , X5& , X7$ , X7$ , ] Password (12 digits, user or admin)
NOTE: Password is option. If no password is being used, type EX5^ , X5& CM
]
Read mail server IP, domain name
E CM } X5^ , X5& , X7$ , X7$ , ]
NOTES:
X5^ = IP/Gateway address ###.###.###.### (server IP address)
X5& = E-mail domain name For example, extron.com
X6) = Subnet mask nnn.nnn.nnn.nnn
255.255.0.0 = default
X6# = Verbose mode 0 = Clear or none (default for Telnet connection)
1 = Verbose mode (default for RS-232 and RS-422 connections)
2 = Tagged responses for queries,
3 = Verbose mode and tagged for queries
X7$ = Password 12 digits and alphanumeric, user or admin
SMX System MultiMatrix Switcher • SIS Configuration and Control 57
Command
Set e-mail recipient
Read e-mail recipient
Set e-mail events for recipient
Example:
View e-mail events for recipient
Set serial port parameters
Read serial port parameters
Set mode
Read mode
Set current conn port timeout
Read current conn port timeout
Configure global IP port timeout
Read global IP port timeout
ASCII Command
(Host to Switcher)
E X8@ , X8!
CR }
EX8@ CR }
E I65,02,00,2EM }
E
E
E
E
CY
0*
0TC
1*
}
X8*
}
X8*
TC
TC
}
}
Response
(Switcher to Host)
Ipr X8@ , X8!
, ]
X8!
, ]
X7)]
Pti0* X8*]
X8*]
Pti1* X8*]
Sets e-mail address to account
EX8#X8@ , X9) , X8$ , X8% EM } X9) Ipe X8# , X8@ * X8$ * X8% ...
X8%]
02IpeI65*00*2222222222222222
EX8#X8@ , X9) , X8$ EM } X8%X8%X8%
...
X8%]
Additional Description
Read e-mail address of account
]
E * X5!
, X6^ , X6& , X6* , X6( CP } Cpn X5!
Ccp X6^ , X6& , X6* , X6(]
EX5!
CP } X6^ , X6& , X6* , X6(]
EX5!
* X7) CY } Cpn X5!• Cty X7)] Sets port X5!
for RS-232 or
RS-422 control.
X8@ .
E 1TC } X8*]
NOTES:
X5!
= Specific port number 01 - 02
X6^ = Baud rate: 9600 = default
19200
38400
115200
X6& = Parity: O = odd
E = even
N = none
M = mark
S = space
X6* = Data bits 7, 8
X6( = Stop bits 1, 2
X7) = Port type 0 = RS-232 (default)
1 = RS-422
X8!
= E-mail recipient address
X8@ = E-mail account 65 - 72
X8# = Notification selection 1 I = inputs
F = fans
P = power supply
X8$ = Notification selection 2 If X8# = I, then X8$ = 00 (all inputs), or 1 - 16
If X8# = F, then X8$ = 00 (both fans), 01 (fan 1), or 02 (fan 2)
If X8# = P, then X8$ = 00 (both power supplies), 01 (PS 1), or 02 (PS 2)
X8% = Notify when ? 0 = no response
1 = failed or missing
2 = fixed or restored
3 = both 1 and 2
4 = suspend
5 = un-suspend
X8* = The number of seconds x10 1 - 65000 = 10 - 650,000 seconds
before timeout on IP connections 30 = default (300 seconds)
X9) = Slot address 00 = fan and power supply
01 - 10 = inputs
X8@ .
SMX System MultiMatrix Switcher • SIS Configuration and Control 58
SMX Control
Software
The Windows-based Extron SMX Control Program, which communicates with the SMX via the RS232/RS422 port and the Ethernet port, provides an easy way to set up ties and sets of ties.
The program is compatible with Windows 2000, Windows XP or later. Updates can be downloaded from the Extron website ( www.extron.com
).
Topics in this section include:
•
Installing and Starting the SMX Control Program
•
•
TIPS:
• The HTML language reserves certain characters for specific functions. The SMX does not accept these characters as part of preset names, the switcher name, passwords, or locally created file names.
• Unless otherwise specified, the following characters are invalid or not recommended for SMX inputs: + ~ , @ = ‘ [ ] { } < > “ ; : | \ ? and space
Installing and Starting the SMX Control Program
The SMX can be operated via the Windows-based SMX Control Program. This program is contained on the Extron Software Products DVD (included with the SMX). Install and run this program on a Windows-based PC connected to either of the SMX serial ports or the
Ethernet port (see b and d
, for connection information). It cannot be run from the DVD.
Installing the Program
1. Insert the DVD into the drive. The DVD self starts and the Extron Software window opens.
NOTES:
• The DVD starts only if you have a DVD drive on your PC.
• If the disc does not start automatically, run LAUNCH.EXE from the disc drive.
SMX System MultiMatrix Switcher • SMX Control Software 59
2. Click the Software tab.
3. Scroll to the SMX Control Program and click Install .
4. Follow the on-screen instructions. The installation program creates a C:\Program
Files\Extron\SMX folder.
Within this folder are created three icons for the SMX Control pgm, SMX Help, Uninstall
SMX Control pgm.
Starting the Program
1. Click Start > Programs > Extron Electronics > SMX Control Program > SMX
Control Pgm (or select the desktop icon, if created during installation).
The Comm Port Selection window appears.
2. Choose the comm (serial) port that is connected to the SMX or select IP [LAN] .
NOTE: For a comm port, check the baud rate displayed in the comm port selection window. To change the baud rate, click the Baud button and select the desired baud rate from the list.
SMX System MultiMatrix Switcher • SMX Control Software 60
•
•
If you select a comm port, click OK
and proceed to the Using the Program
section on page 62.
If you selected IP [LAN], click OK and proceed to step 3.
• If you selected Emulate, click OK and proceed to the
section on page 61.
3. If you selected IP [LAN] in step 2, the IP Connection window opens. Set up the connection as follows: a. The Matrix IP Address field defaults to the last IP address entered. A drop-down list to the right contains the most recently used IP addresses.
Select the desired IP address from the list or enter it in the field.
NOTE: 192.168.254.254 is the factory-specified default IP address.
b. If the SMX is password-protected, enter the appropriate administrator or user password in the Password field.
c. Click Connect . The SMX Control Program is ready for operation.
•
•
•
If you logged on using an administrator password, the program connects to the
SMX with all of the administrator rights and privileges.
If you logged on with a user password, the program connects you to the SMX with only user capabilities.
If an incorrect password is entered, the program beeps and returns to the password entry dialog box.
Using Emulation Mode
Emulation mode allows you to set up the software without attaching the SMX to the computer. To use Emulation mode, do the following:
1.
Open the SMX Control Program (see Starting the Program
on page 60)
2. From the Comm Port Selection window, select Emulate and click OK .
3. Choose an emulation file to open and click OK . The file DEMO_SMX10.MTX provides a sample of a completed matrix setup. Selecting the file NEW.INI or clicking Cancel provides a blank setup.
SMX System MultiMatrix Switcher • SMX Control Software 61
4. Select the file name under which you want to save any changes to the file and click OK .
The SMX Physical Configuration [Emulation Mode] window appears.
5. Select the signal type boards, board sizes, plane addresses, and matrix model for which you are preparing a configuration and click Take .
6. The SMX Control Program window opens (see
below).
Using the Program
At startup, the SMX Control Program window appears (see figure 30). The window displays the current configuration of the SMX (the numbered boxes represent the video and audio inputs and outputs and initially opens at the lowest plane). Each plane has a separate numbered tab from 0-15, that are shown at the right side of the main window (in the example below, only planes 0 and 1 are being used).
NOTE: Each SMX system configuration varies per installation. The screens shown throughout this section may look different from the ones displayed on your computer.
Figure 30. Video Inputs and Outputs on Plane 0 — No Ties
SMX System MultiMatrix Switcher • SMX Control Software 62
Each tab is selectable and highlights when selected (see figure 31 for an example of audio inputs and outputs on plane 1).
Figure 31. Audio Inputs and Outputs on Plane 1 — No Ties
Across the top of the main window is the menu bar, and at the right edge of the window, various selectable buttons are available, depending on the current configuration.
NOTE: Depending on the particular SMX configuration, some menus, submenus, and buttons may appear grayed out and are not selectable.
Control Program Menus and Pages
There are six top level menu items on the menu bar: File , Tools , Audio-input Config ,
Preferences , Master Reset , and Help .
File menu
This drop-down list (see figure 32) includes the following items: Save Matrix settings as...
, Restore Matrix settings from...
, Save This-Session’s settings ,
Restore Last-Session’s Settings , Select printer...
, Print Tie Map , and Exit .
Figure 32. File Menu
• Save Matrix settings as... — Select this option to save the current matrix settings
(ties, presets, virtual plane, and audio settings) to a restorable file (*.mtx).
SMX System MultiMatrix Switcher • SMX Control Software 63
• Restore Matrix settings from... — Select this option to restore saved matrix settings files (*.mtx) and overwrite the current settings.
NOTE: All current settings (ties, presets, virtual plane, and audio settings) unless already saved, are replaced.
• Save This-Session’s settings — Select this option to save the specific session settings (ties, presets, rooms, and audio settings) to file (*.ini), which can be used for restoring those settings later.
NOTE: The last saved settings within the same *.ini file are overwritten.
• Restore the Last-Session’s settings — Select this option to restore the last session settings from a saved file ( * .ini).
NOTE: The current settings (ties, presets, rooms, and audio settings) are overwritten by the restored settings.
• Select Printer — Selecting this opens a second drop-down list listing the available printers connected to the PC.
• Print Tie Map — Select this option to print the tie map in the active window to the default or currently selected printer.
• Exit — Select this option to close the SMX control program. Current settings are maintained and loaded upon restart.
NOTE: Alternatively, click on the red X in the top right corner of the main window to close the SMX Control Program.
Tools Menu
This drop-down list (see figure 33) includes the following items: Assign Device Icons ,
Edit Device Palette , RGB Delay settings , Audio-Input Gain settings ,
Audio-Output Volume settings , Mute-Output settings , HD-SDI Re-clocker
Rate settings , EDID settings , HDCP Status , USB Settings/Status , View Input
Frequencies , Update Firmware...
, IP Options , HTML File Manager , Hardware
Status , Physical Switchers config , Virtualize...
, and Name Presets .
Figure 33. Tools Menu
SMX System MultiMatrix Switcher • SMX Control Software 64
• Assign Device Icons — Select this option to add specific device icons to the main window input and output boxes. This opens a new window showing input and output device icons. Drag and drop an icon onto the applicable input or output boxes.
NOTE: Alternatively, clicking on either input or output boxes opens the relevant icon window. Drag and drop an icon onto the boxes.
• Edit Device Palette — Selecting this option opens the Editor window (see figure 34).
To edit an icon name, swap, or upload a new icon, select the icon number, click Edit and follow the on-screen prompts. Any changes made are shown in the Device Palette when next selected (see
Customizing the SMX Window on page 75).
Click Close to exit the Device Palette Editor window.
Figure 34. Device Palette Editing Windows
• RGB Delay settings (VGA and RGBHV boards only)
— Select this option to change and set RGB Delay for any selected outputs. The RGB Delay & Mute Adjust window opens.
NOTE: To select all outputs, check the ALL box.
To change or set RGB delay:
1. Select an output (or All ) and adjust the RGB Delay slider to set the desired delay (in 0.5 second steps).
2. Click Take to accept the change, or click Cancel to ignore the change.
3. Click Close to exit the window.
NOTE: This menu also contains mute output settings (see
on page 66 for the procedure).
SMX System MultiMatrix Switcher • SMX Control Software 65
• Audio-Input Gain settings — Select this to change the audio gain (0.5 dB steps) for all or single inputs.
To change the gain, pick an input (or All ) and use the adjustment arrows to raise or lower the gain.
NOTE: Click on the applicable Changes radio buttons to have any changes either immediate or verifiable.
Verify (default setting) accepts changes after the Take button is pressed.
Immediate accepts changes instantly. The
Take button is removed.
•
•
Click Take (if visible) to accept the changes.
Click Use Defaults to set the selected input to the default setting.
• Click Cancel Change to return the gain to the previous setting.
• Audio-Output Volume settings — Select this option to change the audio volume
(in 1% steps) for all or single outputs.
To change the volume, pick an output (or All ) and raise or lower the volume slider.
NOTE: When an RGB input is connected, this menu also shows the RGB delay settings (see
RGB Delay settings on page 65).
Click Close to exit the window.
To mute video or audio output, select either check box in the Mute box per selected output number (or All ).
• Mute-Output settings — Select this option to mute any or all video or audio outputs.
To mute a video or audio signal, select an output (or All ) and check the video or audio mute box. The output is now muted, and the output box in the main window indicates the mute status.
Click Close to exit the window.
NOTE: When an RGB input is connected, this menu also shows the RGB delay settings (see
RGB Delay settings on page 65).
• HD-SDI Re-clocker Rate settings — Select this option to reset the reclocking rate for HD-SDI inputs.
The Re-clocker rate sets the outputs in sync with input signals.
If an audio board is set to the plane address, a slider will become available for volume adjustment in this dialog box.
SMX System MultiMatrix Switcher • SMX Control Software 66
• EDID settings — Select this option to set the EDID settings for selected inputs, and to save the output to any of four user defined outputs.
Select Advanced Info
to view the EDID data for any selected output (see the above right
side image), and to save a record to a user defined ID (User 1-4).
NOTE: The drop-down list has 41 selections, where: 15 is the default for DVI
(1024x768 @ 60 Hz), 32 is the default for DVI-Pro (720p), 0 = automatic, 1 - 8 is data stored from connected EDID monitors as reference, 9 - 26 are factory fixed rates, and 37 - 40 are user assignable ( 37 = User 1, 38 = User 2, 39 = User 3,
40
on page 41 for the full list.
• HDCP Status — Select this option to view whether inputs or outputs are connected with HDCP compliance. This information can also be viewed by selecting EDID
Settings .
• USB Settings/Status — Select this option to view the connection status and port emulation settings for USB boards. Select the numbered check boxes in the Port
Emulation section to enable or disable the port emulation feature of SMX USB boards.
• View Input Frequencies — Select this to view the horizontal and vertical frequencies for any input. Click Refresh to manually update the list.
NOTE: If the Frequency-read options setting under the Preferences menu is set to None , then View Input
Frequencies is not available.
SMX System MultiMatrix Switcher • SMX Control Software 67
• Update Firmware... — Select this option to update the SMX with the latest firmware.
Before using this command, download the latest firmware version from the Extron website ( www.extron.com
):
1. On the Extron Web page, select the Download tab.
2. Click the Firmware link on the left sidebar menu.
3. Click on “ S ,” scroll to SMX Multi Matrix switcher, and then click Download .
4. Fill in the required information, then click Download product name_firmware version .exe.
5. In the File Download - Security Warning window, click Save .
6. In the Save As window, browse to the folder where you want to save the firmware file, and click Save . The firmware installation file (*.S19) is saved on your hard drive.
To upload the firmware to the SMX:
1. Select Update Firmware and browse to the folder where the downloaded firmware file (*.S19) was saved.
2. Select the applicable file and click Open . The file is uploaded.
When the SMX unit has restarted, check that all the previous ties and settings have been restored and restart any control programs (for example, DataViewer, SMX
Control Program, web pages) that were previously open.
• IP Options — Select this to view and change the IP settings, Date/Time settings, and
Administrator/User access names and passwords for the SMX, E-mail addresses and notification settings can also be changed.
SMX System MultiMatrix Switcher • SMX Control Software 68
To change the IP settings complete the applicable fields or check the User DHCP box to automatically obtain an IP address. The Take button appears and the Close button changes to Cancel . Click Take to accept the changes or Cancel to reset the fields to the previous settings. Click Close to close the window.
NOTE: Fields that appear grayed out are not changeable.
To change the date and time settings, complete the applicable fields or click the Sync time to PC button.
To create or change the administrator and user passwords, edit the applicable fields.
NOTE: An administrator password must be created before a user password can be.
The characters + ~ , @ = ‘ [ ] { } < > ` “ “ ; : | \ ?
and space are invalid or not recommended in passwords.
To add or configure e-mail addresses, complete the fields as desired.
• HTML File Manager — Select this option to add or remove user created web files.
SMX System MultiMatrix Switcher • SMX Control Software 69
To select a file from the server list, click Pick Files to Load to Server , then click
Get Selected Files...
or Delete Selected Files...
as desired.
Click Update to refresh file list.
• Hardware status — Select this option from the Tools menu to check status of various hardware components, view serial port configuration, and view firmware details.
• Click Update to refresh the window with real time information.
• Click Close to exit the window.
• Physical Switchers config — Select this option to view the I/O board types and sizes per slot.
SMX System MultiMatrix Switcher • SMX Control Software 70
• Virtualize... — Select this option to view and set up to 10 virtual planes. Select a Virtual Plane check box then select the desired Physical Planes check boxes. Select Take . New tabs for the virtual planes (planes 1 and 5 in the example below) appear on the inputs page. This recreates configurations from current boards and configurations onto virtual planes.
• Name Presets — Select this to assign or edit preset names.
Audio-input-Config
NOTE: This menu title is grayed-out until an audio plane is selected.
Upon selection of this menu, the Configure Audio Options window opens.
• Configure Audio Options — Sets the dB gain per audio input.
Click on the applicable Changes radio buttons to have the changes be either immediate or verifiable.
• Immediate removes the Take button from the window and all changes are made immediately.
• Verify (default setting) allows accepting the changes via a Take button.
In verify mode, click on the up or down arrow for the an input until you reach the desired gain value (range is -18 to 24 dB, default 0 dB), then click Take . The dB value is shown in black for current values, but turns red when changes are pending or green when the pending change is returned to its original value. Click Take to confirm pending changes.
If you desire default values (0 dB), click Use Defaults .
SMX System MultiMatrix Switcher • SMX Control Software 71
Click Cancel Chgs if you want to cancel pending changes and restore the previous settings.
To set all audio inputs to the same gain level, use the All arrows to select the required level.
Preferences
This drop-down list (see figure 35) includes the following selectable items: Immediate
Changes , Hold/Verify Changes , Ties as Lines , Ties as Crosspoints ,
Frequency-read options , Icons in I/O boxes , Numbers in I/O Boxes , and Catch
FPC/other’s Changes .
Select or deselect an item from the Preferences menu as required. When an option is selected, a check mark is visible.
Figure 35. Preferences Menu
• Immediate Changes — Selecting this option allows input-to-output tie changes to happen immediately without the need to use the Take button.
• Hold/Verify Changes — Selecting this option requires a click of the Take button to accept changes to ties.
SMX System MultiMatrix Switcher • SMX Control Software 72
• Ties as Lines — Selecting this option displays input to output ties as lines.
• Ties as Crosspoints — Selecting this option displays input-to-output ties as points.
The crosspoints diagram is shown as a matrix with ties that have been made indicated by green boxes. Pending ties that will be made after the Take button is clicked appear as a + while ties that will be broken appear as a in the Crosspoint box.
• Frequency-read options — Selecting this option displays a submenu with three selectable items: Automatically every 10 seconds , On Demand (or by
Refresh) , and None . Select the input read and update frequency as desired.
NOTE: When the Frequency-read options setting is set to None , the View
Input Frequencies option on the Tools menu is not available.
• Icons in I/O Boxes — Select this option to show user-assigned icons, or numbers in sequence in the I/O boxes (see the
section on page 75).
• Numbers in I/O boxes — Select this to have the input or output number displayed in the boxes.
• Catch FPC/other’s changes — Select this option to have the SMX report all configuration and setting changes via the remote RS-232, RS-422, or Ethernet connection. These reports allow the SMX Control Program to track the changes that occur in the switcher configuration and settings, whether commanded via the front panel, the RS-232/RS-422 port, or the Ethernet port.
SMX System MultiMatrix Switcher • SMX Control Software 73
Master-Reset
Select this menu only if a master reset to factory defaults is desired. It opens a warning window stating the consequences of this action. Click No if the reset is not required. Click
Yes to proceed and complete the reset.
Help
This menu gives access to the SMX Control Program help file, and displays limited SMX configuration information.
Figure 36. Help Menu
Select Contents to view a help file that can orient you through the various menus and commands.
The configuration information (not selectable or configurable) section shows:
• Model type and slot count (here a 3U SMX with 6 slots and front panel control)
• Board signal configuration (here 8x8 video inputs and outputs)
• Firmware version (here 1.14)
• Login mode (here logged in as administrator)
• Unit connection (here IP/LAN with the default IP address)
Select Firmware Ver. = x.xx to open two windows.
Figure 37. Firmware Version and RS-232 Monitor Window
The first shows the SMX main firmware version and build number (version 1.14, build 0041 in the example above).
The second window is the RS-232 monitor which shows the switcher response.
SMX System MultiMatrix Switcher • SMX Control Software 74
Select About this Program to see the software version number. Click OK to close the pop-up window.
Customizing the SMX Window
In the SMX window, the inputs and outputs are represented by boxes. Customize the control program view by assigning device icons that represent the connected devices to each input and output box.
1. Click on an input or an output box. The Input Devices or Output Devices window opens, containing icons representing various types of devices that may be connected to the
SMX.
2. Click and drag an icon from the devices screen to an input or output box on the program window. Repeat for additional devices, as desired.
3. In the Caption field, enter a caption (for example, Laptop ) for the device, if desired.
This caption appears in the descriptive window that pops up when you pass the cursor over an input or output box containing an icon.
SMX System MultiMatrix Switcher • SMX Control Software 75
4. When you are finished assigning icons, click OK to close the device window.
To change an icon in an input or output box, drag the new icon to the box. The previous icon is replaced.
To remove the icon and leave the box empty, drag an empty square from the Devices window to the box.
Alternatively, you can display the input and output numbers in the boxes. To do this, select
Numbers in I/O Boxes from the Preferences menu.
Managing Ties
You can create, remove, and view input-to-output ties in the SMX Control program.
To create a tie
• Click and drag an input box outline over to an output box.
• If Hold/Verify Changes has been selected in the Preferences menu, a broken line connecting the two boxes appears, indicating a pending tie.
NOTE: If you want to undo the pending tie, click Cancel . The broken line disappears.
Click Take to confirm the tie. The broken line becomes solid.
Figure 38. Completed Ties (Solid) and Pending Ties (Broken Lines)
• If Immediate Changes has been selected from the Preferences menu, the tie is made immediately, a solid line appears, and the Cancel and Take buttons are not displayed.
SMX System MultiMatrix Switcher • SMX Control Software 76
To remove a tie
Drag the output box outline to its tied input box or to the trashcan.
• If Hold/Verify Changes has been selected from the Preferences menu, the solid tie line becomes broken.
NOTE: If you want to reinstate the tie, click Cancel . The line becomes solid.
Click Take to remove the tie. The broken tie line disappears.
• If Immediate Changes has been selected from the Preferences menu, the tie is removed immediately.
To view information on an input or output
Position the cursor over that device in the matrix window. A pop-up window opens, showing the input and output numbers, names (if captions were specified), details on the connections to that device, and the frequency of the video signal being sent to or from it
(see figure 39).
Figure 39. Matrix Window Section with Output 1 Pop-up Information
IP Settings/Options
The IP Settings/Options window (see figure 40
) lets you view and, if the SMX is connected via the RS-232 or RS-422 link or if you are logged on via the Ethernet port as an administrator, edit settings unique to the Ethernet interface. None of the fields on this screen can be edited while you are logged on as a user.
To display the IP Settings/Options window, select IP Options from the Tools menu.
SMX System MultiMatrix Switcher • SMX Control Software 77
Figure 40. IP Setting/Options Window
NOTES:
• Editing the following fields in the IP Settings/Options window while the SMX is connected via the Ethernet port can immediately disconnect the computer from the unit:
• Matrix IP Address , Gateway Address , Subnet Mask , Use DHCP ,
Administrator Password .
• Extron recommends editing the settings on this screen using the RS-232 or RS-422 link and protecting the Ethernet access to the screen by assigning an administrator password to qualified and knowledgeable personnel only.
• When the control program is connected to the SMX via the RS-232 or RS-422 link, the Administrator and User Password fields are not masked. If a password has been inadvertently changed to an unknown value, you can look it up and, if desired, change a password in this window without knowing the current password.
Setting the IP address
The Matrix IP Address field contains the IP address of the connected SMX. This value is encoded in the flash memory on the switcher.
Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields separated by dots
(periods). Each field can be numbered from 000 through 255. Leading zeroes, up to 3 digits total per field, are optional. Values of 256 and above are invalid.
The default address is 192.168.254.254, but if this conflicts with other equipment at your installation, you can change the IP address to any valid value.
Edit the address field as follows:
1. Click in the Matrix IP Address field. The graphic cursor becomes a text cursor.
2. Make any desired changes to the address.
SMX System MultiMatrix Switcher • SMX Control Software 78
3. Press the <Tab> key on the keyboard or click in another field to exit the Matrix IP
Address field.
4. Click the Take button to make the address change take effect.
NOTE: Editing the IP Address field while the SMX is connected via Ethernet will immediately disconnect your from the SMX. It is recommended that you connect via
RS-232 or RS-422 to edit this field.
Setting the Extron name or descriptor
The Extron Name/Descriptor field contains the name used as the “from” information when the SMX e-mails notification of its failed or repaired status. The default name or descriptor shown in this field is a portion of your product name, followed by the last six characters of the unit MAC address (for example, SMX-05-A6-2D).
This descriptor can be changed to any valid name, up to 24 alphanumeric characters or hyphens.
NOTE: The following characters are invalid or not recommended in the Extron Name/
Descriptor field: + ~ , @ = ` [ ] { } < > ‘ “ “ ; : | \ ?
and space
Edit the Extron Name/Descriptor field as follows:
1. Click in the Extron Name/Descriptor field. The graphic cursor becomes a text cursor.
2. Edit the name as desired.
3. Press the <Tab> key on the keyboard or click in another field to exit the Extron Name/
Descriptor field.
4. Click the Take button to make the name change take effect.
ATTENTION: Editing the Gateway IP Address field while the SMX is connected via Ethernet can immediately disconnect the PC from the SMX. It is recommended that you connect via RS-232 or RS-422 to edit this field.
Setting the subnet mask
The Subnet Mask field is used to determine whether the SMX is on the same subnet as the controlling PC or the mail server when you are subnetting. The subnet mask has the same format as the matrix IP and gateway addresses ( nnn.nnn.nnn.nnn
). For more information, see
on page 111.
Edit this field as follows:
1. Click in the Subnet Mask field. The graphic cursor becomes a text cursor.
2. Make any desired changes to the mask.
3. Press the Tab key on the keyboard or click in another field to exit the Subnet Mask field.
4. Click the Take button to make the changes to the mask take effect.
ATTENTION: Editing the Subnet Mask field while the SMX is connected via
Ethernet can immediately disconnect your PC from the SMX. It is recommended that you connect via RS-232 or RS-422 to edit this field.
Hardware address field
The hardware (MAC) address consists of six pairs of alphanumeric characters in the format xx-xx-xx-xx-xx-xx . The MAC address is hard coded in the SMX and cannot be changed.
SMX System MultiMatrix Switcher • SMX Control Software 79
Enabling and disabling DHCP
Selecting the Use DHCP check box directs the SMX to ignore any entered IP addresses and to obtain its IP address from a Dynamic Host Configuration Protocol (DHCP) server (if the network is DHCP capable). Contact the local system administrator for information about
DHCP on your system.
ATTENTION: Selecting or deselecting this check box while the SMX is connected via
Ethernet can immediately disconnect your PC from the unit. It is recommended that you connect via RS-232 or RS-422 to edit this field.
Setting the date
The Date field displays the current date in the Greenwich Mean Time (GMT) zone. If necessary, adjust the date as follows:
1. Click in the Date field. A date editing field appears, displaying the date in the format
(M)M/(D)D/YYYY . Leading zeros are not used. The graphic cursor becomes a text cursor in the date editing field.
2. Edit the field as desired to set the proper date. Leading zeros are optional.
3. Press the <Tab> key on the keyboard or click in another field to exit the Date field.
4. Click the Take button to make the date change take effect.
Setting the local time
The Time (local) field displays the current time in the local time zone. If necessary, click the Sync Time to PC button to set the SMX to the internal time of your computer, or adjust the time manually as follows:
1. Click in the Time (local) field. A time editing field appears with the date in the format
HH:MM:SS (00:00:00 to 23:59:59) . The graphic cursor becomes a text cursor in the time editing field.
2. Edit the field as desired to set the proper time. Remember to use 24-hour time. Leading zeros are optional.
3. Press the <Tab> key or click in another field to exit the Set Time field.
4. Click the Take button to make the time change take effect.
Sync time to PC button
Clicking the Sync Time to PC button causes the computer you are operating to send its internal time to the SMX in a set time command.
Setting the offset from GMT
The GMT field displays the amount of time, in hours and minutes, that the local time varies from the GMT international time reference. If necessary, adjust the offset as follows:
1. Click in the GMT field. An offset editing field appears with the offset in the format +HH:MM
(-12:00 to + 14:00) . The graphic cursor becomes a text cursor in the set offset field.
2. Edit the field as desired to set the proper offset. Leading zeros are optional. Some time zones are on the half-hour (30 minutes).
3. Press the <Tab> key or click in another field to exit the Set Offset field.
4. Click the Take button to make the offset change take effect.
SMX System MultiMatrix Switcher • SMX Control Software 80
Enabling daylight saving time
When daylight savings time is enabled, the switcher updates its internal clock between daylight saving time and standard time in the spring and fall on the date that the time change occurs in your location. When daylight saving time is turned off, the SMX does not adjust its time reference.
Select the Use Daylight Saving check box to enable daylight saving time.
Setting the administrator password
The Administrator Password field displays the password required to log on to the SMX via the Ethernet port with all administrator rights and privileges.
Passwords are case sensitive and are limited to 12 uppercase and lowercase alphanumeric characters.
While you are logged on as a user, this field is masked with asterisks (************) as a security measure.
NOTE: The following characters are invalid or not recommended for passwords:
+ ~ , @ = ` [ ] { } < > ‘ “ “ ; : | \ ?
and space
ATTENTION: Editing the Administrator Password field while connected through
Ethernet can immediately disconnect you from the SMX. It is recommended that you connect via RS-232or RS-422 to edit this field.
Edit this field as follows:
1. Click in the Administrator Password field. The graphic cursor becomes a text cursor.
2. Make any desired changes to the case-sensitive password.
3. Press the <Tab> key on the keyboard or click in another field to exit the Administrator
Password field.
4. Click the Take button to make the password change take effect.
Setting the user password
The User Password field displays the password required to log onto the SMX via the
Ethernet port as a user, without all administrator rights and privileges. Passwords are case sensitive and are limited to 12 uppercase or lowercase alphanumeric characters.
While you are logged on as a user, this field is masked with asterisks (************) as a security measure.
NOTES:
• The following characters are invalid or not recommended for passwords:
+ ~ , @ = ` [ ] { } < > ‘ “ “ ; : | \ ?
and space
• An administrator password must be created before a user password.
Edit this field as follows:
1. Click in the User Password field. The graphic cursor becomes a text cursor.
2. Make any desired changes to the case-sensitive user password.
3. Press the <Tab> key on the keyboard or click in another field to exit the User Password field.
4. Click the Take button to make the password change take effect.
SMX System MultiMatrix Switcher • SMX Control Software 81
Setting the mail server IP address
The Mail Server IP Address field displays the IP address of the mail server that handles the e-mail for the facility in which the SMX switcher is installed.
Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields separated by dots
(periods). Each field can be numbered from 000 through 255. Leading zeros, up to 3 digits total per field, are optional. Values of 256 and above are invalid.
Edit this field as follows:
1. Click in the Mail Server IP Address field. The graphic cursor becomes a text cursor.
2. Make any desired changes to the mail server IP address.
3. Press the <Tab> key on the keyboard or click in another field to exit the Mail Server
IP Address field
4. Click the Take button to make the address change take effect.
Setting the mail server domain name
The Mail Server Domain Name field displays the domain name that the SMX uses to log on to the e-mail server. Standard domain conventions (such as @xxx.com
) apply.
NOTE: The following characters are invalid or not recommended in a domain name:
+ ~ , @ = ` [ ] { } < > ‘ “ “ ; : | \ ?
and space . The @ character is acceptable only as the lead-in to the domain name (such as @folklore.net
).
Edit this field as follows:
1. Click in the Mail Server Domain Name field. The graphic cursor becomes a text cursor.
2. Edit the name as desired.
3. Press the <Tab> key on the keyboard or click in another field to exit the Mail Server
Domain Name field.
4. Click the Take button to make the name change take effect.
Entering e-mail addressee information
The eight E-mail Addressee fields permit the administrator to identify the e-mail addresses of the personnel to whom the SMX e-mails notification of its failure and repair status (see figure 41 for a typical e-mail message from the SMX).
Figure 41. Typical SMX E-mail
The radio buttons and check boxes associated with each address field permit the administrator to specify e-mail requirements for each recipient.
Edit these fields and controls as follows:
1. Click in the desired E-mail Addressee field. The graphic cursor becomes a text cursor.
2. Edit the e-mail address as desired. Standard e-mail address conventions (such as [email protected]
) apply.
3. Press the <Tab> key on the keyboard or click in another field to exit the e-mail addressee field.
SMX System MultiMatrix Switcher • SMX Control Software 82
4. Use the check boxes associated with each addressee to select the options about which the addressee will be e-mailed: missing inputs or power supply.
5. When you select either a radio button or a check box for an addressee, the floating box that contains the input numbers is displayed on the Input Settings/Options screen.
Select the inputs that need monitoring by clicking on their numbers in this box. Selected input numbers are displayed in white on a gray field. To deselect an input number, click on it again (see
).
6. Use the round radio buttons associated with each addressee to select whether the addressee will be e-mailed about failures, fixes, both, or not be notified. The
None radio button temporarily removes personnel from the e-mail list when they are unavailable, in cases of traveling or being on vacation.
7. If desired, click the Send Test E-mail button to test the e-mail function.
8. Click the Take button to make the e-mail address changes take effect.
Updating the firmware
The update firmware utility provides a way to replace the firmware that is coded on the SMX control board. Update the SMX firmware as follows:
NOTE: The update firmware utility is for replacing the firmware that controls all switcher operation. This is not the page to insert your own HTML pages (see
Files on page 85 to insert custom HTML pages).
1. Visit the Extron website, www.extron.com
, and download the latest firmware file to your computer.
a. On the Extron website, select the Downloads tab.
b. On the Download Center page, click the Firmware link on the left sidebar menu.
c. Click S and navigate to your SMX type.
d. On the next screen, fill in the required information, then click the Download product name_firmware version.exe
button.
e. On the File Download - Security Warning window, click Save .
f. On the Save As window, browse to the folder here you want to save the firmware file, and click Save . The firmware installation file is placed on your hard drive.
2.
Start the SMX Control Program and connect your computer to the SMX (see Using the
Program on page 62 for the procedure).
NOTE: The Ethernet connection is faster than the RS-232/RS-422 connection. Use the Ethernet connection rather than the serial port for firmware uploads.
SMX System MultiMatrix Switcher • SMX Control Software 83
3. From the Tools menu, select Update Firmware...
. The Select Files window opens
(see figure 42).
Figure 42. Select Files Window with Firmware File Selected
4. Navigate to the folder where you saved the firmware file. Select the file.
ATTENTION: Valid firmware files must have the file extension .S19. Any other file extension is not a firmware upgrade and could cause the SMX to cease functioning.
NOTE: The original factory-installed firmware is permanently available on the SMX. If the attempted firmware upload fails for any reason, the SMX reverts to the factoryinstalled firmware.
5. Click Open . A confirmation prompt window opens, reminding you that loading the selected .S19 file will reprogram the device firmware.
6. Click OK to continue with upload. A status window, which shows the progress of the upload, appears. The firmware upload to the SMX may take a few minutes.
7. When the upload is complete, another prompt window appears, informing you that the new firmware upgrade will cause the SMX to reset, which will terminate the connection with your computer and close the control software. Click OK .
If you want to continue using the SMX Control Program, restart it.
SMX System MultiMatrix Switcher • SMX Control Software 84
Uploading HTML files
You can create customized HTML pages for the SMX to display. The HTML Files List window (see figure 43) provides a way to view the contents of the SMX file system and to upload custom HTML pages to the SMX.
Figure 43. HTML Files List Window
Upload HTML pages as follows:
NOTES:
• The files listed in the figure 43 are shown for example only and may not be present on your switcher.
• The HTML Files List window is for inserting your own HTML pages. This is not the window to replace the firmware that controls all switcher operation. To replace the firmware (see
on page 83).
• The following characters are invalid or not recommended in file names:
+ ~ , A = ‘ [ ] { } < > ` “ “ ; : | \ ?
and space
1. Connect the PC to the SMX via the switcher RS232/RS422 port or Ethernet port.
2. Start the
SMX Control Program and connect to the SMX (see Using the Program
on page 62 for the procedure).
3. From the Tools menu, select HTML File Manager . The HTML Files List window opens.
4. Click the Pick File(s) to Load to Server button. The Select files window opens.
5. Navigate to the folder where you saved the HTML files. Select the files.
NOTES:
• To select multiple files, hold the Ctrl key while clicking the desired files.
• If you want one of the HTML files that you created to be the default start-up page, name the file “index.html.” The SMX automatically looks for that file name when first connecting to it using an Internet browser.
6. Click the Open button. The file uploading process may take a few minutes.
7. Click the Update button to confirm the upload.
8. Click the Close button to exit the HTML Files List window.
SMX System MultiMatrix Switcher • SMX Control Software 85
Windows buttons, menus, and trashcan
The buttons, drop-down lists, and trash can on the right side of the program window perform the following functions:
Power — This button is unavailable for SMX switchers, because the SMX cannot be powered on and off via software.
Executive Mode — Locks out front panel operations, except for the viewonly mode functions.
Presets menu — Displays a list of up to 32 global presets and up to 10 plane presets. From this list you can select a global or plane preset to display in the window, then either activate the selected preset by clicking Go or delete it by clicking Delete .
Go — Activates the selected preset as the current configuration.
Save as — Saves the current set of ties as a global or plane preset. Enter a preset number for it when prompted to do so.
Delete — Deletes the selected global or plane preset to be deleted.
Take — Saves to file any changes made to the displayed configuration.
Cancel — Returns to the previous screen, undoing any changes you have made.
Trashcan — Drag and drop from an input or output button to the trashcan to undo all ties associated with that input or output.
SMX System MultiMatrix Switcher • SMX Control Software 86
HTML Configuration and Control
The SMX can be configured and controlled through its Ethernet port, connected through a
LAN or WAN and accessed with a Web browser such as Microsoft Internet Explorer. The browser displays the factory-installed Web pages, which provide an alternative means of viewing and controlling the SMX. This section includes:
•
•
•
•
•
NOTE: If your Ethernet connection to the SMX is unstable, try turning off the proxy server in your Web browser. To do this in Microsoft Internet Explorer, click Tools >
Internet Options > Connections > LAN Settings , and clear the Use a proxy server...
check box. Click OK.
TIPS:
• The HTML language reserves certain characters for specific functions. The SMX does not accept these characters as part of preset names, the switcher name, passwords, or locally created file names.
• Unless otherwise specified, the following characters are not recommended or invalid for SMX inputs: + ~ , @ = ‘ [ ] { } < > “ ; : | \ ? and space
Accessing the Web Pages
Access the HTML pages as follows:
1. Start the Web browser program.
2. Click in the browser Address field and enter your SMX IP address (see figure 44).
NOTE: If the local system administrators have not changed the value, the factory-specified default, 192.168.254.254, is the correct value for this field.
Figure 44. Internet Explorer Address Field
3. To view a non-default page instead (such as an uploaded custom page), enter a slash (/) and the name of the file to open.
NOTES:
• The browser Address field should display the address in the following format:
xxx.xxx.xxx.xxx/optional_file_name.html .
• The following characters are invalid or not recommended in the file names: ~ @
= ‘ [ ] { } < > “ ; : | \ ? and space
SMX System MultiMatrix Switcher • HTML Configuration and Control 87
4. Press the <Enter> key. The SMX checks to see if it is password-protected.
If the SMX is not password-protected, the System Status Web page is displayed.
If the SMX is password-protected, the network password dialog box is displayed
(see figure 45).
5. In the Password field, enter the appropriate administrator or user password. If desired, select the check box to have the system input the password the next time you enter the
SMX IP address. Click OK .
Figure 45. Example of a Network Password Dialog Box
NOTE: A entry is not required. Some Web pages may not be available or viewable only when logged in as a user.
The SMX checks several possibilities, in the following order, and responds accordingly:
• Does the address include a specific file name, such as 192.168.254.254/file_ name.html
? If so, the SMX downloads that HTML page.
•
•
Is there a file in the SMX memory that is named “index.html?” If so, the SMX downloads “index.html” as the default startup page.
If neither of the above conditions is true, the SMX downloads the factory-installed default startup page, “nortxe_index.html” (System Status page, see figure 46).
Any of the four main pages (System Status, Configuration, File Management, and Control) can be accessed at any time by clicking on the relevant tab. Each main page has a series of sub-pages, accessible through the named links in the sidebar menu.
Figure 46. System Status Page Set to the Default Home Page
SMX System MultiMatrix Switcher • HTML Configuration and Control 88
System Status Pages
The System Status pages give access to sub-pages: System Status (the default page),
Physical Configuration, and DVSP and HDCP. To view each individual page, click on the links in the sidebar menu.
System Status
The System Status (see figure 47) page has the following sections: System Information
(such as unit name and model), Power Status, and Serial Port Settings. This read-only page updates itself periodically to reflect the latest status of the switcher components. If a variable changes, the display shows the change in status the next time it updates.
Figure 47. System Status Page
SMX System MultiMatrix Switcher • HTML Configuration and Control 89
Physical Configuration
The Physical Configuration read-only page lists the currently installed boards for the SMX system, showing the size and the total slots of that frame. For each slot, it shows the installed board function or type, board size, and the plane address allocated to that board
(see figure 48).
DSVP
Figure 48. Physical Configuration Page
The Digital Sync Validation Processing (DSVP) page displays the current signal status and source of connected video inputs per board. For VGA/RGBHV boards, the horizontal and vertical frequencies per slot are also shown (see figure 49).
Figure 49. DSVP Pages for HD-SDI (top) and VGA (with H and V Data)
SMX System MultiMatrix Switcher • HTML Configuration and Control 90
Configuration Pages
The Configuration pages allow system settings (IP address, date/time etc.), passwords
(Admin and User), and E-mail settings (mail addresses) to be configured as desired.
Additionally, the current firmware can be upgraded by selecting the Firmware Upgrade link.
System Settings Page
The SMX displays the System Settings page (see figure 50) after selecting the
Configuration tab. The screen consists of fields in which you can view and edit IP
administration and system settings (see Ethernet Control on page 106 for basic
information about IP addresses and subnetting).
Figure 50. System Configuration Page
On password-protected connections, there are two levels of protection: administrator and user. Administrators have full access to all switching capabilities and editing functions. Users can create ties, create and recall presets, and view all settings not password-protected.
• Ethernet connection to the switcher for entering SIS commands (see
SIS Configuration and Control on page 34) or for using the SMX Control Program
(see
on page 59), is password-protected.
• Connection via the RS-232/RS-422 port is not password-protected.
SMX System MultiMatrix Switcher • HTML Configuration and Control 91
IP Settings Fields
The IP Settings section provides a location for viewing and editing settings unique to the
Ethernet interface. After editing any of the settings on this page, click the Submit button at the bottom of the IP Settings section (see figure 51).
f
Figure 51. IP Settings Fields a Unit Name field — The Unit Name field contains the name used as the “from” information when the SMX E-mails notification of its failed or repaired status. You can change this name field to any valid name, up to 24 alphanumeric characters.
NOTE: The following characters are invalid or not recommended in the matrix names: + ~ , @ = ‘ [ ] { } < > “ ; : | \ ?
b DHCP radio buttons — Contact the local system administrator to determine this control setting. The DHCP On radio button directs the switcher to ignore any entered
IP addresses and to obtain its IP address from a Dynamic Host Configuration Protocol
(DHCP) server (if the network is DHCP capable).
The DHCP Off radio button turns DHCP off.
c IP Address field — The IP Address field contains the IP address of the connected
SMX. This value is encoded in the switcher flash memory.
Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields separated by dots
(periods). Each field can be numbered from 000 through 255. Leading zeros, up to
3 digits total per field, are optional. Values of 256 and above are invalid.
The factory-installed default address is 192.168.254.254, but if this conflicts with other equipment at your installation, you can change the IP address to any valid value.
NOTE: IP address changes can cause conflicts with other equipment. Only local system administrators should change IP addresses.
d Gateway IP Address field — The Gateway IP Address field identifies the address of the gateway to the mail server to be used if the switcher and the mail server are not on the same subnet. The gateway IP address has the same validity rules as the system IP address.
e Subnet Mask field — The Subnet Mask field is used to determine whether the switcher is on the same subnet as the mail server when you are subnetting (see
on page 111).
f MAC Address field — The Media Access Control (MAC) address is hard coded in the switcher and cannot be changed.
g Firmware field — This field shows the firmware version number. This field changes only when the firmware is updated.
h Model field — This field shows the model (SMX) and cannot be changed.
i Part Number field — This field shows the SMX part number (60-855-01) and cannot be changed.
SMX System MultiMatrix Switcher • HTML Configuration and Control 92
Date/Time Settings fields
The Date/Time Settings section (see figure 52) provides a location for viewing and setting the time functions.
Figure 52. Date/Time Settings Fields
Change the date and time settings as follows:
1. Click the drop-down box for the desired variable. The adjustable variables are month, day, year, hours, minutes, am/pm, and (time) zone (see figure 52).
2. Click the scroll up or down buttons until the desired variable is visible.
3. Click on the desired variable.
NOTES:
• If setting the time, set the local time. The Zone variable allows you to then enter the offset from Greenwich Mean Time (GMT).
• The Zone field identifies the standard time zone that has been selected and displays the amount of time, in hours and minutes, that the local time varies from the GMT international time reference.
4. Repeat steps 1 through 3 for other variables that need to be changed.
5. Select the appropriate Daylight Saving radio button. To turn off daylight savings time, select Off .
NOTE: When daylight savings time is enabled, the switcher updates its internal clock between Standard Time and Daylight Savings Time in the spring and fall on the date that the time change occurs in the United States of America and parts of
Europe and Brazil. When daylight savings time is turned off, the switcher does not adjust its time reference.
6. Click the Submit button at the bottom of the Date/Time Settings section to implement the selections.
SMX System MultiMatrix Switcher • HTML Configuration and Control 93
Passwords Page
Access the Passwords page (see figure 53) by clicking the Passwords link on the sidebar menu on System Settings page.
Figure 53. Passwords Page
The fields on the Passwords page are for entering and verifying administrator and user passwords. Passwords are case sensitive and are limited to 12 upper- and lowercase alphanumeric characters. Each password must be entered twice—once in the Password field and then again in the Re-enter Password field to the right. Characters in these fields are masked by four bullets (••••). If you do not want to password-protect an access level, leave the Password and the Re-Enter Password fields blank. After entering the desired password in both fields, click the Submit button at the bottom of the page.
NOTES:
• An administrator password must be created before a user password.
• Some Web pages may not be available or may be viewable only, when logged in as an administrator.
To clear an existing password so that no password is required, delete the bullets in the
Password and Re-enter Password fields and enter a space in each field, then click the
Submit button at the bottom of the page.
Email Settings Page
The Email Settings page has fields for setting up the SMX e-mail notification capabilities. For each row of the e-mail notification settings, click the Edit button at the right of the field to make the field available for editing. The button changes to Save . After editing the settings associated with the Edit/Save button, click the Save button.
Figure 54. Email Settings Page (Upper Portion)
SMX System MultiMatrix Switcher • HTML Configuration and Control 94
a Mail IP Address field — The Mail IP Address field displays the IP address of the mail server that handles the e-mail for the facility.
Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields separated by dots
(periods). Each field can be numbered from 000 through 255. Leading zeroes, up to
3 digits total per field, are optional. Values of 256 and above are invalid.
b Domain Name field — The Domain Name field displays the domain name that the
SMX uses to log on to the e-mail server. Standard domain name conventions (for example, @xxx.com
) apply.
NOTES:
• The following characters are invalid or not recommended in the domain names:
+ ~ , @ = ‘ [ ] { } < > “ ; : | \ ?
and space
• The @ character is acceptable only as the lead-in to the domain name (such as
@folklore.net
).
c SMTP Authorization Required check box — The SMTP Authorization Required check box sets the SMX to require SMTP authorization before accepting any e-mail. To set up this authorization requirement, follow these steps:
1. To enable the SMTP Authorization fields, click the Edit button at the right of the
Mail IP Address field. The Edit button changes to Save .
2. Select the SMTP Authorization Required check box, located below the Domain
Name field. This enables the User Name and Password fields below the check box.
3. In the User Name and Password fields, enter a user name and a password that senders must enter in order for the SMX to accept their e-mail messages.
For the User Name , use any combination of letters, numerals, spaces, and symbols except the comma ( , ) and the single and double quotation marks ( ‘ and “ ). For the password, you can use all characters except the comma. The user name and password can each be from 1 to 30 characters.
NOTE: You must specify both a user name and a password.
4. Click the Save button next to the Mail IP Address field to save your user name and password.
To remove SMTP authorization, click Edit , deselect the SMTP Authorization
Required check box, then click Save .
Email Address Fields
The eight Email Address fields identify the e-mail addresses of the personnel to whom the
SMX e-mails notification of its failure and repair status. Standard e-mail address conventions
) apply.
The check boxes and drop boxes associated with each address field let you specify criteria under which the SMX will e-mail the recipients.
Click Edit to make changes. Click Save
to save the changes (see figure 55 ).
• In the Missing Input drop-down list to the left of the address, select the inputs to monitor for presence or absence of a signal.
• Check the Power box to monitor the power supplies.
• In the associated Email Options drop-down list, select whether the recipient is to be e-mailed of failures, fixes, both, not notified, or removed from the e-mail list.
SMX System MultiMatrix Switcher • HTML Configuration and Control 95
Figure 55. Email Options Menu on the Email Settings Page
The Suspend option is useful for temporarily removing personnel from the e-mail list when they are unavailable, such as traveling or vacation. Deleting an e-mail addressee and clicking the Save button removes the recipient from e-mail notification completely.
Firmware Upgrade Page
The Firmware Upgrade page (see figure 56) provides a way to replace the firmware that is coded on the SMX control board without needing to take the switcher out of service.
Figure 56. Firmware Upgrade Page
NOTE: The Firmware Upgrade page is only for replacing the existing firmware. To insert
custom HTML pages (see File Management Page
on page 97).
Update the SMX firmware as follows:
1. Visit the Extron website, www.extron.com
, and download the latest firmware file.
a. On the Extron Web page, select the Downloads tab.
b. On the Download Center page, click the Firmware link on the left sidebar menu.
c. Click on the name of your SMX .
d. On the next screen, fill in the required information, then click the Download product name_firmware version.exe
button.
e. On the File Download - Security Warning window, click Save .
f. On the Save As window, browse to the folder where you want to save the firmware file, and click Save .
2. Access the SMX Web pages.
3. Select the Configuration tab.
4. On the Configuration page, click the Firmware Upgrade link on the left sidebar menu.
5. Click the Browse button. A Choose File window opens.
6. Navigate to the folder where you saved the firmware upgrade file. Select the file.
SMX System MultiMatrix Switcher • HTML Configuration and Control 96
ATTENTION: Valid firmware files must have the file extension “.S19.” Any other file extension is not a firmware upgrade and could cause the SMX to cease functioning.
NOTE: The original factory-installed firmware is permanently available on the SMX. If the attempted firmware upload fails for any reason, the SMX reverts to the factory-installed firmware.
7. Click Open .
8. On the Firmware Upgrade page, click the Upload button. While the firmware is uploading, the Upload button changes to Uploading...
. When the uploading process is complete, the button changes back to Upload . The process may take a few minutes.
File Management Page
This page allows you to upload or delete user files (such as HTML pages and graphics) from the SMX (see
on page 85 for another method of uploading files).
Figure 57. File Management Page
NOTE: The files listed in the figure above are shown for example only and may not be present on your SMX.
SMX System MultiMatrix Switcher • HTML Configuration and Control 97
Uploading Files
Files to be uploaded may only contain valid alphanumeric characters and underscores.
NOTE: The following characters are invalid or not recommended in the files names:
+ ~ , @ = ‘ [ ] { } < > “ ; : | \ ?
and space
To upload files to the SMX, follow these steps:
1. Click the Browse button to the right of the file name field on the File Management Web
Page.
2. Browse to locate the file that you want to upload, and open it. The name and directory path of the file are displayed in the file name field on the File Management screen.
3. Click the Upload File button. The selected file name appears in the Files column (files are listed separately under headings of their extensions).
NOTE: If you want one of the pages that you create and upload to be default startup page, name that file “index.html.”
Adding a Directory
To add a directory or folder to the SMX file system, follow these steps:
1. Enter the directory name in the Dir: field, following the slash (/).
2. Click the Add Dir button.
3. With the directory name displayed, perform the
procedure on page 85 to add a file to the directory. The directory name appears at the top of the Files column, preceded by a slash.
To add more files to the directory, click the directory name to open it, then use the uploading files procedure. To exit the directory, click (root) or (back) .
Other File Management Activities
You can also perform the following tasks on the File Management screen:
Open a file — Click on the name of the file in the Files column.
Delete a file — Click the Delete button in the row of the file to be removed.
Delete All files — Click the Delete All button to delete all files.
Display files by file extension — The Filter by File Extension menu lists the extensions of the files that have been uploaded to the SMX. This menu lets you choose to display only files with the extension you select. Select All to display all uploaded files.
Control Pages
The Control pages allow limited device configuration. From the User Control page, setting and viewing of input-to-output ties, viewing and adjustment of input audio levels, output volume levels, muting status, and the configuring and saving of EDID data are possible across all allocated plane addresses. The Preset page allows global and plane presets to be saved and recalled.
User Control Page
The User Control page emulates some of the front panel features and displays the current input-to-output ties, input audio level, output volume, A/V mute status, and current EDID
on page 13 for additional descriptions.
SMX System MultiMatrix Switcher • HTML Configuration and Control 98
To set or replace ties
1. Select the desired plane from the drop-down list (see figure 58).
NOTE: When you select a plane, only the available adjustment fields show on the screen, according to the output board type installed and addressed.
1 2
3
Figure 58. Control Pages — User Control Page
2. In the Signal Type section, click Video only , Audio only , or Video & Audio , depending on the signal type to be tied.
NOTE: When viewing the ties on the User Control page, video ties are shown green, audio ties are red, and video and audio ties amber (see figure 58).
3. Click the desired combination of input and output buttons in the Set & View Ties map.
The button changes color according to signal type and indicates a provisional tie with a letter “P” (see figure 58, input 6, output 7, for example).
NOTE: An existing tie to an input is replaced by the new input tie. Click Cancel to abandon changes and revert back to the existing ties.
4. Click Take to make the ties. The page refreshes, the letter “P” disappears from the button and the SMX is updated with the new tie.
To remove ties
1. Select the desired plane from the drop-down list.
2. In the Signal Type section, click Video only , Audio only , or Video & Audio , depending on the signal type to be removed.
3. Click the desired combination of input and output buttons of the tie to be removed. The button changes color and indicates a provisional tie with a letter “P” (see figure 58).
SMX System MultiMatrix Switcher • HTML Configuration and Control 99
NOTES:
• If a video tie is removed from a video and audio tie, the button turns red (from amber).
• If an audio tie is removed from a video and audio tie, the button turns green
(from amber).
• If a single signal tie (video or audio) is removed, or there is a combined signal
(the Video & Audio signal type button is highlighted), the Video Only or Audio
Only button turns gray (see figure 58 , input 6, output 7).
4. Click Take to make the tie. The screen refreshes, the letter “P” disappears from the button, and the SMX is updated, removing the selected tie.
To set input audio levels
1. In the Input Adjustments section, click in the desired input audio level field. A drop-down list of dB values (+24 to -18 dB) appears (see figure 59, input 4).
Figure 59. Drop-down List of dB Values
2. Scroll down to the desired level and click. The page refreshes and the device updates to the selected level.
SMX System MultiMatrix Switcher • HTML Configuration and Control 100
To set output volume levels
1. In the Output Adjustments section, click in the desired output volume field. A dropdown list of volume settings (0 to 64) appears (see figure 60, output 6).
Figure 60. Drop-down List of Volume Settings
2. Scroll down to the desired level and click. The page refreshes and the device updates to the selected level.
NOTE: Alternatively, use the + and – buttons to increase or decrease the level one step at a time. The page refreshes and the device updates every time the buttons are clicked.
SMX System MultiMatrix Switcher • HTML Configuration and Control 101
To mute or unmute a signal
1.
In the Signal Type field (see b, figure 58 ), click
Video only , Audio only , or Video &
Audio , depending on the signal type to be muted.
Figure 61. A/V Mute Button Status
2. In the Output Adjustment section, click Mute to mute the output. The button changes
color according to the muted signal (see the Note below and figure 61), and changes to
Muted . The page refreshes and the SMX updates with the selection.
NOTES:
• If the output is muted for audio only, the button is red.
• If the output is muted for video only, the button is green.
• If the output is muted for video and audio, the button is amber.
SMX System MultiMatrix Switcher • HTML Configuration and Control 102
EDID configuration
1. In the Plane section, select the plane that has an EDID-supporting output board installed.
2. In the EDID Configuration section, click the applicable input number and scroll down to the resolution and refresh rate desired (see figure 62, input 7).
NOTE: The drop-down list has 41 selections (see the
Figure 62. EDID Configuration Settings
3. If using User Assigned 1 - 4 , click one of the Save Output 1 User buttons (1-4) as desired. The DDC data is saved under the User Assigned number for recall.
4. To save an EDID setting to a user assignable number (User Assigned 1 through 4), connect the display (that you want the EDID data for) to Output 1 only and turn on the monitor.
5. Press a User button to save the data. The saved data can be recalled later.
SMX System MultiMatrix Switcher • HTML Configuration and Control 103
Presets Page
The Presets page allows global and plane presets to be saved to one of 32 locations for global presets, or to one of the 10 locations for plane presets.
NOTE: Global presets save and recall configurations for all planes, and plane presets save and recall configurations for a specific plane, not affecting other planes.
Saving the current configuration as a global preset
1. In the Global Presets section, click Save Preset . The button changes to Select
Preset...
, and grays out.
NOTE: All unassigned buttons become active. The plane preset field grays out.
2. Select the desired preset by clicking one of the preset buttons.
• To create a new preset, click one of the [unassigned] buttons.
• To overwrite an existing preset, click its button.
3. Enter a name for the preset in the text field.
NOTES:
• Preset names are limited to 12 characters. Valid characters are
0 - 9 , a - z , A - Z , _ : = / and space
• The following characters are invalid or not recommended in the preset names: +
~ , @ = ‘ [ ] { } < > “ ; : | \ ?
4. Click the Accept button.
If you do not rename an unassigned button, the SMX names the preset as Preset nn (where nn corresponds to the next global preset number).
The SMX retains the same preset name if it is not renamed when it is overwritten.
SMX System MultiMatrix Switcher • HTML Configuration and Control 104
Recalling a global preset
To recall a global preset as the current configuration, click the button for the desired preset in the Global Presets section.
Saving the current configuration as a plane preset
1. In the Plane Preset section, click the plane drop-down list, and select the relevant plane.
2. Click Save Preset . The button changes to Select Preset...
, and grays out.
NOTE: All unassigned buttons become active. The global preset field grays out.
3. Select the desired preset by clicking one of the preset buttons.
• To create a new preset, click one of the [unassigned] buttons.
• To overwrite an existing preset, click its button.
4. Enter a name for the preset in the text field.
NOTES:
• Preset names are limited to 12 characters. Valid characters are
0 - 9 , a - z , A - Z , _ : = / and space
• The following characters are invalid or not recommended in the preset names: +
~ , @ = ‘ [ ] { } < > “ ; : | \ ?
5. Click Accept .
If you do not rename an unassigned button, the SMX names the preset as Preset nn
(where nn corresponds to the next plane number).
The SMX retains the same preset name if it is not renamed when it is overwritten.
Recalling a plane preset
To recall a plane preset as the current configuration, on the Plane Presets page, select the relevant plane, then click the button for the desired preset.
SMX System MultiMatrix Switcher • HTML Configuration and Control 105
Ethernet Control
This section describes Ethernet connection and Telnet communication to the SMX and includes:
•
•
Ethernet Link
The rear panel Ethernet connector on the SMX can be connected to an Ethernet
LAN or WAN. This connection makes SIS control of the SMX possible using a computer connected to the same network.
Ethernet Connection
The Ethernet cable can be terminated as a straight-through cable or a crossover cable and must be properly terminated for your application (see figure 63).
• Crossover cable — Direct connection between the computer and the SMX.
• Patch (straight) cable — Connection of the SMX switcher to an Ethernet LAN.
Pins:
12345678
Straight-through Cable
(for connection to a switch, hub, or router)
End 1
End 1
Pin Wire Color
End 2
End 2
Pin Wire Color
1
1 white-orange
2
3 orange
1 white-orange white-green blue
2
3 orange white-green blue
3 white-green
4 blue
6
7
5 white-blue green
3 white-green
4 blue
6
7 green white-brown brown 5 white-blue brown
(for direct connection to a PC)
End 1
1 white-orange
2 orange
Crossover Cable
3 white-green
4 blue
5 white-blue
End 2
Pin Wire Color
1 white-green
2 green
3 white-orange
4 blue
5 white-blue
Side View
Insert
Twisted
Pair Wires
RJ-45 Connector
6 green 6 green
7 white-brown 7 white-brown
(for direct connection to a PC)
8 brown 8 brown
End 1
Pin Wire Color
End 2
Pin Wire Color
6 green
7 white-brown
8 brown
6 orange
7 white-brown
8 brown
Figure 63. RJ-45 Connector Pinout Tables
3 white-green 3 white-orange
Default Address
4
5 blue white-blue
4
5 blue white-blue
6
7 green white-brown
6
7 orange white-brown been changed to an address comprised of words and characters, the actual numeric IP address can be determined using the ping utility. If the address has not been changed, the factory-specified default is 192.168.254.254.
Ping can also be used to test the Ethernet link to the SMX.
SMX System MultiMatrix Switcher • Ethernet Control 106
Ping to determine Extron IP address
The ping utility is available at the command prompt. Ping tests the Ethernet interface between the computer and the SMX. Ping can also be used to determine the actual numeric
IP address from an alias and to determine the web address.
Ping the SMX as follows:
1. From the Windows Start menu, select All Programs > Accessories >
Command Prompt . The Command Prompt window opens.
NOTES: The command prompt can also be accessed from the Run...
field.
• For Windows 7, click the Windows Start menu, and enter cmd in the Search
Programs and Files field. Select Cmd from the list.
• For older Windows operating systems, click the Windows Start menu and select Run...
. In the Run window, enter command in the Open field and click OK .
2. At the prompt, enter ping < IP address >. The computer returns a display similar to figure 64.
3. The Pinging...
line reports the actual numeric IP address, regardless of whether you entered the actual numeric IP address or an alias name.
C:\>ping 192.168.254.254
Pinging 192.168.254.254 with 32 bytes of data:
Reply from 192.168.254.254: bytes=32 time<10ms TTL=128
Reply from 192.168.254.254: bytes=32 time<10ms TTL=128
Reply from 192.168.254.254: bytes=32 time<10ms TTL=128
Reply from 192.168.254.254: bytes=32 time<10ms TTL=128
Ping statistics for 192.168.254.254:
Packets: Sent = 4, Received = 4, Lost = 0 (0% loss),
Approximate round trip times in milli-seconds:
Minimum = 0ms, Maximum = 0ms, Average = 0ms
Figure 64. Ping Response
Ping to determine Web IP address
The ping utility has a modifier, -a , that directs the command to return the web address rather than the numeric IP address.
At the command prompt, enter ping -a IP address . The computer returns a response similar to the ping response shown in figure 64, except that when you specify the -a modifier, the Pinging mail...
line reports the web IP address instead of the numeric IP address, regardless of whether you entered the actual numeric IP address or an alias name.
Configuring the SMX for Network Communication
To function together, both the PC and the SMX must be configured correctly. The PC must be network-capable with the proper protocols, and the SMX must be set up so it can be connected to a LAN or other network.
When powering the SMX on for the first time, set up the IP address one of these ways:
• Use the SMX Control Program software via the LAN connector.
• Use the ARP (address resolution protocol) command via the LAN connector.
• Use a Web browser via the LAN connector.
• Use SIS commands via Telnet and the LAN connector.
SMX System MultiMatrix Switcher • Ethernet Control 107
If you use a web browser or Telnet the first time you connect a PC to an SMX via IP, you may need to temporarily change the IP settings of the PC in order to communicate with the switcher. Then you must change the switcher default settings (IP address, subnet mask, and
[optional] administrator name and password) in order to use the unit on an intranet (LAN) or on the Internet. After you have set up the SMX for network communication, you can reset the PC to its original network configuration.
SMX LAN port defaults:
• SMX IP address: 192.168.254.254
• Gateway IP address: 0.0.0.0
• Subnet mask: 255.255.0.0
• DHCP: off
• Link speed and duplex level: autodetected
NOTE: Both the computer and the SMX must be connected to the same subnet on a
LAN (using a straight-through cable). Alternatively, you can use a crossover Ethernet cable to connect the controller directly to the Ethernet card.
The following instructions assume that you have already connected the PC to the SMX LAN port and powered on the controller and the PC.
Configuring the SMX for Network Use Via the ARP Command
The ARP (address resolution protocol) command tells your computer to associate the SMX
MAC (media access control) address with the assigned IP address. You must then use the ping utility to access the SMX, at which point the SMX IP address is reconfigured.
Use ARP to configure the IP address as follows:
1. Obtain a valid IP address for the SMX from your network administrator.
2. Obtain the SMX MAC address (UID number) from the label on its rear panel. The MAC address should have this format: 00-05-A6-xx-xx-xx.
3. If the SMX has never been configured and is still set for factory defaults, go to step 4.
If not, perform a Mode 4 system reset. For detailed information on reset modes (see
Using Reset Levels on page 32).
4. At the PC, access the command prompt, then enter the arp -s command. Type in the desired new IP address for the unit and the unit MAC address. For example: arp -s 10.13.197.7 00-05-A6-03-69-B0
Figure 65. ARP Command
NOTE: The MAC address is listed on the rear panel.
After the arp -s command is issued, the SMX changes to the new address and starts responding to the ping requests, as described in the next step.
SMX System MultiMatrix Switcher • Ethernet Control 108
5. Execute a ping command by entering ping followed by a space and the new IP address at the command prompt. For example: ping 10.13.197.7
You must ping the SMX in order for the IP address change to take place. The response should show the new IP address, as shown in the following picture.
Figure 66. Ping Command
To verify that the update was successful, reconnect using either Telnet or a Web browser.
6. After verifying that the IP address change was successful, enter the arp -d command at the DOS prompt. For example: arp -d 10.13.197.7
removes 10.13.197.7 from the ARP table or arp -d* removes all static IP addresses from the ARP table.
Connect as a Telnet Client
The Telnet utility is available from the command window. Telnet allows you to input SIS commands to the SMX from the PC via the Ethernet link and the LAN.
Access the Command window and start Telnet as follows:
1. From the Windows Start menu, navigate to and select All Programs > Accessories
> Command Prompt . A command window opens.
NOTES: The command prompt can also be accessed from the Run...
field.
• For Windows 7, click the Windows Start menu, and enter cmd in the Search
Programs and Files field. Select Cmd from the list.
• For older Windows operating systems, click the Windows Start menu and select Run...
. In the Run window, enter command in the Open field and click OK .
2. At the prompt, enter telnet . A window similar to figure 67 opens.
Figure 67. Telnet Window
SMX System MultiMatrix Switcher • Ethernet Control 109
Telnet tips
It is not the intention of this guide to detail all of the operations and functionality of Telnet; however, some basic level of understanding is necessary for operating the SMX through
Telnet.
Connecting to the SMX (Open command)
Connect to the SMX using the Open command. Once your computer is connected to the
SMX, you can enter the SIS commands the same as you would if you were using the
RS-232 link.
Connect to the SMX as follows:
1. At the Telnet prompt, enter open < IP address >.
If the SMX is not password-protected, no further prompts are displayed until you disconnect the PC from the SMX .
If the SMX is password-protected, Telnet displays the password prompt.
2. If necessary, enter the password at the password prompt.
Ethernet connection to the switcher can be password-protected. There are two levels of password-protection: administrator and user.
A person logged on as an administrator has full access to all SMX switching capabilities and editing functions.
A person logged on as a user can select test patterns, mute or unmute the output, select a blue screen, and view all settings with the exception of passwords. By default, the switcher is delivered with both passwords set to carriage return.
Once logged in, the SMX returns either Login Administrator or Login User . No further prompts are displayed until the computer is disconnected from the SMX .
Escape character and Esc key
When Telnet is first started, the utility advises that the escape character is Ctrl+] . Many
SIS commands include the keyboard <Esc> key. Consequently, some confusion may exist between the escape character and the <Esc> key.
The Telnet escape character is a key combination: The <Ctrl> key and the <]> key pressed simultaneously. Pressing these keys displays the Telnet prompt while leaving the connection to the SMX intact.
The escape key, used for SIS commands, is the <Esc> key on the keyboard.
Local echo
Once the computer is connected to the SMX, by default, Telnet does not display keystrokes on the screen. SIS commands are entered blindly, and only the SIS responses are displayed on the screen. To command Telnet to show all keystrokes, enter set local_echo at the
Telnet prompt before you open the connection to the switcher.
With local echo turned on, keystrokes and the SMX responses are displayed on the same line. Example: 1*1*1!01Out01 In01 All where 1*1*1!
is the SIS command and 01Out01
In01 All is the response.
Note that all keystrokes are displayed, even those that should be masked, such as the password entry. For example, when entering a password with local echo turned on, a*d*m*i*n* is displayed, where admin is the keyed-in password and ***** is the masked response.
Local echo can be turned off by entering unset local_echo at the Telnet prompt. If the computer is connected to the SMX, and you need to access the Telnet prompt to turn local echo off, enter the escape sequence (<Ctrl> + <]>).
SMX System MultiMatrix Switcher • Ethernet Control 110
Setting carriage return line feed
Unless commanded otherwise, Telnet transmits a line feed character only (no carriage return) to the connected switcher when the <Enter> key is pressed. This is the correct setting for SIS communication with the SMX. The Telnet set crlf command forces Telnet to transmit carriage return and line feed characters when <Enter> is pressed; however, if crlf is set, the SIS link with the switcher does not function properly.
Closing the link to the switcher
To close the link to the SMX, access the Telnet prompt by entering the escape sequence
(<Ctrl> + <]>). At the Telnet prompt, enter close .
Help
For Telnet command definitions, enter ?
at the Telnet prompt.
Exiting Telnet (Quit command)
Exit the Telnet utility by entering quit at the Telnet prompt. If you are connected to the SMX switcher, access the Telnet prompt by entering the escape sequence (<Ctrl> + <]>).
Subnetting — A Primer
A subnet is a subset of a network — a set of IP devices that have portions of their IP addresses in common. It is not the purpose of this manual to describe TCP/IP protocol in detail. However, some understanding of TCP/IP subnetting is necessary in order to understand the interaction of the SMX and the mail server gateway. To understand subnetting at the level required to install and operate the SMX, you must understand the concepts of a gateway, local and remote devices, IP addresses and octets, and subnet masks and octets.
Gateways
The SMX can communicate with the e-mail server that it uses for e-mail notification directly
(if they are on the same subnet), or the communication can be routed through a gateway
(a computer that provides a link between different subnets).
Local and Remote Devices
The local and remote devices are defined from the point of view of the function being described. In this guide, subnetting is an issue when you are using the controlling PC to set
TCP/IP and e-mail values in the SMX (see
IP Settings/Options on page 77,
on page 59,
Email Settings Page on page 94, and
include subnetting, the SMX is the local device and the e-mail server is the remote device.
IP Addresses and Octets
Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields, properly called octets, which are separated by dots (periods) (see figure 68). Each octet can be numbered from
000 through 255. Leading zeros, up to 3 digits total per octet, are optional. Values of 256 and above are invalid.
Typical IP Address: 192.168.254.254
Octets
Figure 68. IP Address and Octets
SMX System MultiMatrix Switcher • Ethernet Control 111
Subnet Masks and Octets
The subnet mask (see figure 69) is used to determine whether the local and remote devices are on the same or different subnet. The subnet mask consists of four numeric octets separated by dots. Each octet can be numbered from 000 through 255, up to 3 digits total per octet. Leading zeros are optional. The octets determine whether or not the same octets of two IP addresses will be compared when determining if two devices are on the same subnet.
255 indicates that this octet will be compared between two IP addresses.
Typical Subnet Mask: 255.255.0.0
Octets
0 indicates that this octet will not be compared between two IP addresses.
Figure 69. Subnet Mask and Octets
Determining Whether Devices Are on the Same Subnet
To determine the subnet, the local device IP address is compared to the remote device IP address (see figure 70). The octets of each address are compared or not, depending on the value in the related subnet mask octet.
• If a subnet mask octet contains the value 255, the related octects of the local device address and the remote device IP address are unmasked.
Unmasked octets are compared (indicated by ?
in figure 70).
• If the subnet mask octet contains the value 0, the related octets of the local device and remote device IP addresses are masked.
Masked octets are not compared (indicated by X in figure 70).
If the unmasked octets of the two IP addresses match (indicated by = in figure 70, example 1), the two addresses are on the same subnet.
If the two unmasked fields do not match (indicated by ≠ in figure 70, example 2 and example 3), the addresses are not on the same subnet.
Local IP Address:
Subnet Mask:
Remote IP Address:
Match?:
Example 1
192.168.254.254
255.255.0.0 (?.?.X.X)
192.168.2.25
=.=.X.X — Match
(Same subnet)
Example 2
192.168.254.254
255.255.0.0 (?.?.X.X)
190.190.2.25
≠.≠.X.X — No match
(Different subnet)
Example 3
192.168.254.254
255.255.0.0 (?.?.X.X)
192.190.2.25
=.≠.X.X — No match
(Different subnet)
Figure 70. Comparing the IP Addresses
SMX System MultiMatrix Switcher • Ethernet Control 112
Reference
Information
This section identifies part numbers for related products, describes mounting procedures, and button label customizing. This section includes:
•
•
•
Mounting the Switcher
NOTE: The SMX comes in 2U, 3U, 4U, or 5U sizes. Before attempting installation, ensure the rack is able to accommodate your particular device size.
Install the Four uninstalled rubber feet only if the unit is to be mounted on top of a table (see
Tabletop Placement).
Tabletop Placement
For tabletop placement, install the (provided) self-adhesive rubber feet onto the four corners of the bottom of the device.
UL Guidelines for Rack Mounted Devices
The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the
SMX device in a rack.
1. Elevated operating ambient temperature — If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient temperature. Therefore, install the SMX in an environment compatible with the maximum ambient temperature (Tma = + 122 ˚F, + 50 ˚C) specified by Extron.
2. Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised.
3. Mechanical loading — Mount the equipment in the rack so that a hazardous condition is not achieved due to uneven mechanical loading.
4. Circuit overloading — Connect the equipment to the supply circuit and consider the effect that circuit overloading might have an overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
5. Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
SMX System MultiMatrix Switcher • Reference Information 113
Rack Mounting
To rack mount the SMX, use two screws on each end of the switcher to attach it to the rack
(see figure 71).
Figure 71. Mounting the SMX
Button Labels
Page 119 provides strips of blank button labels. If desired, photocopy them or cut them out
of the guide, write button information in each button area as desired, and put them in the
SMX input or output buttons windows. Labels can be created using the Extron
Button-Label Generator software.
Using the Button Label Generator
The Button Label Generator software creates labels that you can place inside the translucent covers of the input and output push buttons (see
on page 117 for procedures for removing the replacing the translucent covers). You can create labels with names, alphanumeric characters, icons, and even colored bitmaps for easy and intuitive input and output selection.
The program is contained on the same DVD as the SMX Control Program and is installed automatically when you install the control software.
By default, the software files are placed in the C:\Program Files\Extron\
ButtonLabelGenerator directory. The Button Label Generator icon is placed in the
“Extron Electronics” group or folder.
1. To run the Button Label Generator program, double-click on the Button Label
Generator icon (shown at right) in the Extron Electronics group or folder. The Button
Label Generator window appears (see figure 72).
SMX System MultiMatrix Switcher • Reference Information 114
Figure 72. Button Label Generator Window
2. From the Systems drop-down list, select a system button configuration.
The Matrix Switchers 3232 or 1616 selections most closely match the button configuration of the SMX (the SMX option gives you four rows of blank buttons).
However, you can select any option from this menu. Selecting Customize Button
Layouts opens a blank worksheet on which customized buttons can be placed in any desired configuration.
3. Click on the button representation that you want to edit. A red box surrounds the selected button.
4. Edit the selected button by using any of the tools provided on the Button Label
Generator window. Some of the edits you can make are:
•
•
Enter text and select the font, text size, and text color from the drop-down lists on the menu bar.
Select an icon from the Button Picture Palate and drag it to a button.
• Place a bitmap image from your computer on a selected button.
To remove all the text or the image from a button, click Clear Button . To remove the text and images from all the buttons, click Clear All Buttons .
To access the Help program, select Use Help from the Help menu.
5. After creating the labels, print them out by selecting Print from the File menu in the upper-left corner of the Button Label Generator window.
To save the button label set as an .xml file on your computer, select Save As from the
File menu and give the label a file name.
SMX System MultiMatrix Switcher • Reference Information 115
Replacing Button Labels
The button caps are pre-labeled for your convenience. However, you can change them with the included button labels.
The button assembly consists of a clear lens cap, the button label, and a white diffuser (see figure 73). Remove the button assembly from the SMX as follows:
1.
Make new labels using either the blanks on page 119
or the
Button Label Generator software. Cut the labels out.
2. Remove the button assembly by inserting a small, flat head screwdriver, between the button base and the diffuser to gently pry the button assembly off the button plunger, as shown in the drawing at right.
3. Locate the small corner notch on the lens cap, and slide the screwdriver between the lens cap and the diffuser (see 1 in figure 73).
4. Rotate the screwdriver and carefully pry the two pieces apart
(see 2 in the figure 73).
Pry the button from the base.
3. Remove and replace
label as desired.
2. Pry apart the two pieces
(lens and diffuser)
at the corner.
TEXT
Diffuser
Button Label
Base (inside front panel)
1. Separate the
two-piece button
cap from the base.
Clear Lens
Figure 73. Replacing a Button Label
5. Lift out the transparent square label that you want to replace. You may need to use the small screwdriver to gently pry the label out.
6. Insert one of the new labels you created in step 1 into the clear button cap, align the white backing plate with the cap, and firmly snap it into place.
7. Gently, but firmly, press the reassembled button into place on the SMX front panel.
8. Repeat steps 1 through 7 as needed to relabel other buttons.
SMX System MultiMatrix Switcher • Reference Information 116
Button Label Blanks
SMX System MultiMatrix Switcher • Reference Information 117
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to:
USA, Canada, South America, and Central America:
Extron Electronics
1230 South Lewis Street
Anaheim, CA 92805
U.S.A.
Japan:
Extron Electronics, Japan
Kyodo Building, 16 Ichibancho
Chiyoda-ku, Tokyo 102-0082
Japan
Europe and Africa:
Extron Europe
Hanzeboulevard 10
3825 PH Amersfoort
The Netherlands
China:
Extron China
686 Ronghua Road
Songjiang District
Shanghai 201611
China
Asia:
Extron Asia
135 Joo Seng Road, #04-01
PM Industrial Bldg.
Singapore 368363
Singapore
Middle East:
Extron Middle East
Dubai Airport Free Zone
F12, PO Box 293666
United Arab Emirates, Dubai
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions, or if modifications were made to the product that were not authorized by Extron.
NOTE: If a product is defective, please call Extron and ask for an Application Engineer to receive an RA (Return
Authorization) number. This will begin the repair process.
USA: 714.491.1500 or 800.633.9876
Asia: 65.6383.4400
Europe: 31.33.453.4040
Japan: 81.3.3511.7655
Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions.
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.
Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
Extron Headquarters
+1.800.633.9876 (Inside USA/Canada Only)
Extron USA - West Extron USA - East
+1.714.491.1500 +1.919.850.1000
+1.714.491.1517 FAX +1.919.850.1001 FAX
Extron Europe
+800.3987.6673
(Inside Europe Only)
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+800.7339.8766
(Inside Asia Only)
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
Extron China
+4000.398766
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Middle East
+971.4.299.1800
+971.4.299.1880 FAX
© 2013 Extron Electronics All rights reserved. www.extron.com
Extron Korea
+82.2.3444.1571
+82.2.3444.1575 FAX
Extron India
1800.3070.3777
Inside India Only
+91.80.3055.3777
+91.80.3055.3737 FAX
Contact Information
Download
Advertisement
Key features
Modular and configurable
Hot swappable input/output boards
Multiple input formats
Front panel control
RS-232 and RS-422 control
Ethernet control
Presets
Audio follow and breakaway
Digital Sync Validation Processing
Upgradeable firmware
Frequently asked questions
Up to 32 individual I/O configurations may be saved and recalled
Up to 10 presets per switching plane can be saved and recalled without affecting the other I/O plane connections.
The firmware that controls all switcher operation can be upgraded on location through the serial port or the Ethernet port, without taking the switcher out of service. Firmware upgrades are available for download on the Extron website, www.extron.com, and they can be installed using the Windows-based control program or the built-in HTML pages.
Connect the SMX to an Ethernet LAN or WAN via the RJ-45 connector marked LAN. Ethernet connection allows the operator to control the switcher from a remote location.
Each board has a 16-position rotary switcher for setting the I/O plane address.