Extron electronics RCP 2000 is a versatile remote control panel that offers a range of features for controlling video and audio systems, including wipe, dissolve, and title effects, as well as picture adjustment capabilities such as color, tint, contrast, brightness, and detail. With its intuitive interface and dedicated buttons for various functions, the RCP 2000 allows for precise control over the connected devices, making it an ideal choice for professional AV installations.
Διαφήμιση
Διαφήμιση
RCP 2000 with ISS 506 Support
Setup Guide
This guide provides procedures for setting up and configuring the Extron RCP 2000 Remote Control Panel with ISS 506
Support.
IP Setup
The RCP 2000 is delivered with a factory default IP address of 192.168.254.253. If you want to change this address, or need to enter other information required for Ethernet or serial communication, follow these steps:
1 . Press the Color/Tint, Cont/Bright,
Size, and Center picture control buttons simultaneously and hold them until the Cut button lights (about
2 seconds). The RCP's MAC address is displayed on the LCD screen.
2 . Press the Cut or Take button repeatedly to step through the IP Setup menu options to access the item to be changed.
Step
1
COLOR
TINT
Press and hold all four buttons.
PICTURE CONTROLS
CONT
BRIGHT
SIZE CENTER DETAIL
3 . If adjusting one of the four IP settings (RCP
IP address, switcher IP address, subnet mask, or Gateway), press the Color/Tint,
Cont/Bright, Size, or Center button to select an address block (octet) to change. The selected octet on the LCD screen blinks.
PROGRAM
2 3 4 5 6 7 8
2 3 4 5 6 7 8
LOGO 1
/BLACK
LOGO 2
/BLACK
AUTO
IMAGE
LOGO 1
/BLACK
LOGO 2
/BLACK
4 . Rotate the H Adjust knob to change the selected value.
ION
PREVIEW
5 . When finished, press the Detail button to save the configuration and exit IP Setup.
H
V
ADJUST
Wipe an
01 = Dissolve (PIP only) 10 = S
02 = Soft Right 11 = S
03 = Soft Left
04 = Soft Up
12 = S
13 = S
05 = Soft Down
06 = Soft Center In
07 = Soft Center Out
08 = Soft Curtain In
09 = Soft Curtain Out
14 =
15 =
16 =
17 =
A6-00-B7
00-0F-2B
WIPE DISSOLVE
CUT TAKE
After 2 seconds, the display shows the MAC address.
The CUT button lights.
Default
Cycle
Press simultaneously.
COLOR
TINT
CONT
BRIGHT
SIZE CENTER
MAC address
A6-00-B7
00-0F-2B
Press
CUT
Step
1
Press Color/Tint, Cont/Bright, Size, and Center and hold for 2 sec.
Step
2
Press the Cut button to cycle through the IP Setup menu options.
RCP’s IP address
I 010.056
P142.008
Press
CUT
Switcher’s IP
S010.056
I 003.212
Press
CUT
Subnet mask
S255.255
M255.000
Press
CUT
Gateway IP
G010.056
M000.100
Step
3
Press each Picture Control button to select the next IP address segment.
COLOR
TINT
Select
1st octet
CONT
BRIGHT
SIZE
Select
2nd octet
Select
3rd octet
CENTER
Select
4th octet
H 000-255
Press
CUT
Sw Baud
9600
Step
4
Rotate the H knob to change the selected IP address segment, set the baud rate, or turn DHCP on and off.
H
9600-115,200
Press
CUT
RCP Baud
9600
H
9600-115,200
Press
CUT
Press
CUT
DHCP
Off
Step
5
Press the Detail button to save the configuration and exit IP Setup.
DETAIL
68-1608-01 Rev. A
08 08
RCP 2000 with ISS 506 Support Setup Guide (cont'd)
RS-232 Setup
To configure an RS-232 connection to the switcher,
1 . Plug the supplied 12' RS-232 cable into the RCP's rear panel To Switcher port and the switcher's RS-232/422 port.
2 . Press and hold the Color/Tint, Cont/Bright, Size, and Center buttons simultaneously until the Cut button lights and the MAC address appears in the LCD window.
3 . Press Cut two times, until the switcher IP address is displayed in the LCD window. The Color/Tint button flashes.
4 . Set the switcher's IP address to 000.000.000.000 as follows: a . Press one of the picture control buttons to access the desired octet of the switcher's IP address. Access the address blocks as follows:
Press Press Press Press
COLOR
TINT
CONT
BRIGHT
SIZE CENTER
Select 1st octet Select 2nd octet Select 3rd octet Select 4th octet H
Rotate to set blinking octet to 000.
b . When the desired octet is blinking in the LCD window, rotate the H knob all the way to the left to set the address block to 000.
Rotate the H knob to set the switcher's baud rate.
S 000.000
I 000.000
c . Repeat steps a and b as needed for each address block that needs to be set to 000.
5 . If you need to change the switcher's baud rate, press Cut repeatedly until the Sw Baud screen appears.
Sw Baud
9600
6 . Press Detail to exit the setup menu.
Selecting Transition Effects
Selecting wipe, PIP, and title effects
To select a wipe, PIP, or title effect,
1.
Press and hold the Wipe button.
2.
While holding the Wipe button, press the Dissolve
Press and hold
Press to step through menu
WIPE
+
DISSOLVE
Default
Cycle
Press and hold
WIPE
Press
DISSOLVE
H
9600-115,200 button repeatedly to cycle through the Wipe, Pip, and
Title menus.
For Title, press Wipe + Dissolve until Title Lvl is displayed on the LCD screen, then skip to step 4.
3.
When the desired function (Wipe or Pip) is displayed in the LCD window, continue to hold down the Wipe button while turning the Adjust knob to select the number of the desired sub-effect (02 through 25 for
Wipe; 01 through 25 for PIP). See the label in the upperright corner of the RCP front panel for a list of available effects.
Hold
Rotate to select wipe
ADJUST
WIPE
+
Wipe #03
0.5 Sec
ADJUST
02-25
Release
WIPE
ADJUST
Press
DISSOLVE
Pip #03
0.5 Sec
ADJUST
01-25
Release
WIPE
ADJUST
Press
DISSOLVE
Title
Lvl 15 0
Release
WIPE
ADJUST
0-255
0.0-5.0 Sec.
0.0-5.0 Sec.
N You can not select a cut sub-effect while in Wipe or
PIP mode. To perform a cut in these modes, select the desired preview input, then press the Cut button.
4 . Release the Wipe button (it should remain lit), and rotate the Adjust knob to select the duration of the sub-effect (0.0 to
5.0 seconds) or the intensity level (Lvl) of the preview image that will become transparent in Title mode (000 to 255).
N If you want to control the duration of the wipe and PIP effects manually, move the T handle up or down at the desired rate.
5 . Press the Take button to implement your effect on the selected preview input.
2 RCP 2000 with ISS 506 Support • Setup Guide
RCP 2000 with ISS 506 Support Setup Guide (cont'd)
Selecting a cut (full screen program/preview swap)
To select a full screen cut transition (immediate and seamless replacement of the program image with the preview image),
1. With the RCP in Wipe or Dissolve mode, select a preview input.
2. Press the Cut button. The selected preview image immediately becomes the program image.
Press
CUT
Selecting a dissolve
To select a dissolve effect (the program image fades out while the preview image fades in),
1 . Select a preview input.
2 . Press the Dissolve button, which lights.
3 . While the Dissolve button is lit, rotate the Adjust knob to select the duration in seconds
(0.0 through 5.0) of the dissolve effect.
Press
4 . Press Take to execute the dissolve effect.
TAKE
Press
DISSOLVE
+
Rotate to select dissolve duration.
ADJUST
N If you want to control the duration of the dissolve manually, move the T-bar handle up or down at the desired rate.
Using Picture Controls
The Picture Controls buttons, located near the top of the front panel, let you adjust settings on the preview output.
PICTURE CONTROLS
1 . Select a Preview input.
2 . Select a transition effect (wipe, PIP, title, or dissolve).
COLOR
TINT
CONT
BRIGHT
SIZE CENTER DETAIL
3 . Press a picture control button.
4 . Rotate the H and/or V adjustment knobs, located to the right of the buttons, to select the values, as shown below.
Color/Tint Image size Centering
Press
COLOR
TINT
H Adjust color
V
Adjust tint
Col Tint
064 064
Contrast/ brightness
Press
CONT
BRIGHT
H Adjust contrast
V
Adjust brightness
Con Brt
064 064
Detail
Press
DETAIL
Detail
064
H or
V
Adjust sharpness
Pip Det
064
Press
H Adjust width
SIZE
V Adjust height
Wipe, dissolve, and title modes
Hsz 1024
Vsz 0786
PIP mode
H W 0513
V W 0386
Window size
H I 0513
V I 0386
Image size
In PIP mode: Press the Size button again to toggle between window size and image size adjustment.
The Size button stays lit steadily during window size adjustment and blinks during image size adjustment.
Press
H
Adjust horizontal position
CENTER
V
Adjust vertical position
Wipe, dissolve, and title modes
Hsh 2048
Vsh 2048
PIP mode
H W 0640
V W 0480
Window position
H I 0640
V I 0480
Image position
In PIP mode: Press the Center button again to toggle between window position and image position.
The Center button stays lit during window position adjustment and blinks during image position adjustment.
N Picture controls affect only the current preview input.
N If the current PIP or Title preview input is active on the program output, no picture control adjustment is possible.
H
V
RCP 2000 with ISS 506 Support • Setup Guide 3
RCP 2000 with ISS 506 Support Setup Guide (cont'd)
Other Button Controls
The following additional functions are accessed via the Program and/or Preview buttons:
2
FREEZE BLACK
PROGRAM
1 2 3 4 5 6 7 8
LOGO 1
/BLACK
LOGO 2
/BLACK
ADJUS
FREEZE BLACK
1
COMMUNICATION
2 3 4 5 6 7 8
PREVIEW
AUTO
IMAGE
LOGO 1
/BLACK
LOGO 2
/BLACK
1 2 a
Auto Image — Press this Preview button to perform an immediate auto image adjustment on the preview input. Auto Image enables you to automatically size and center the selected preview input to fill the screen.
b
Logo — Press the Logo 1/Black or Logo 2/Black Preview or Program button to display a logo on the screen. If a logo has been assigned, the button lights steadily when pressed.
N Logos must be set up/assigned on the ISS 506 switcher. If no logo is assigned, pressing a Logo button has the same effect as pressing the Black button — a black screen is displayed and the Logo button flashes. (To switch to or from the black screen, apply a cut or other effect.)
Preview User Presets
User presets save color, tint, contrast, brightness, detail, sizing, and centering settings on the ISS 506. Up to three presets can be saved on each input. You can recall a preset that was saved to an input button on the ISS 506 by pressing the equivalent
Preview input button on the RCP.
Preview Input Buttons
FREEZE BLACK
1 2 3 4 5 6 7 8
PREVIEW
COMMUNICATION
AUTO
IMAGE
LOGO 1
/BLACK
LOGO 2
/BLACK
To recall a preset,
1 . Press the desired Preview input button twice to place the RCP in preset mode and start the presets cycle. The first preset name is displayed in the LCD window.
2 . Press the input button repeatedly until the desired preset name is displayed.
To exit preset mode, press another Preview input button.
N If no user presets have been saved, additional presses of the current preview input button have no effect.
User
Preset 1
Extron USA - West
Headquarters
+800.633.9876
Inside USA / Canada Only
+1.714.491.1500
+1.714.491.1517 FAX
Extron USA - East
+800.633.9876
Inside USA / Canada Only
+1.919.863.1794
+1.919.863.1797 FAX
Extron Europe
+800.3987.6673
Inside Europe Only
+31.33.453.4040
+31.33.453.4050 FAX
Extron Asia
+800.7339.8766
Inside Asia Only
+65.6383.4400
+65.6383.4664 FAX
Extron Japan
+81.3.3511.7655
+81.3.3511.7656 FAX
© 2008 Extron Electronics. All rights reserved.
Extron China
+400.883.1568
Inside China Only
+86.21.3760.1568
+86.21.3760.1566 FAX
Extron Dubai
+971.4.2991800
+971.4.2991880 FAX
Λήψη
Διαφήμιση