Реклама
Реклама
41343 12™ Street West PALMDALE, CALIFORNIA € >murphy io a PHONE (661) 272-4700 switch К° À E | | À. FAX (661) 947-7570 SELECTRONIC® CONTROLLER EMS448/447-4 CONTROLLER W\ S449-3 OPERATION MANUAL FOR USE WITH: PROGRAM # A97127.V6 DATE: October 3, 2001 GENERAL INFORMATION DESCRIPTION The EMS Controller is a microprocessor based engine controller with built-in service reminder features. It will automatically warn you when certain service items need to be performed and will signal your engine to shut down if a fault is detected. There are two types of EMS controllers this program will function in. The EMS448 and EMS447. The EMS448 is a complete panel and the EMS447 is in an European type din package for mounting in a larger panel. The system is accessed through three push-buttons and a back-lit, dot-matrix liquid crystal display. A more detailed description of operator functions can be found in the operating instruction section. SENSOR INPUTS The EMS Controller accepts several different types of sensor inputs. Below is a list of which types are accepted. See the wiring hookup drawing for terminal details. Electric Gauge Senders. These inputs allow you to use standard Murphy electric gauge type senders for pressure and temperature. Digital alarm inputs. These inputs are negative grounding type inputs. Typically, external shutdown switches are wired to these inputs. They can include vibration, low pressures, high temperatures, and low levels. Frequency input. This input is an optically isolated speed sensing input. You may get your speed signal from either a magnetic pickup or the tachometer post of your alternator. OUTPUTS The EMS448 controller has a total of seven (7) open collector transistor outputs. One (1) of these can be selected as an input. All outputs are rated for 200 ma. The EMS447 controller has a total of three (3) relay and four (4) open collector transistor outputs. One of the transistor outputs can be selected as an input. The relay outputs are rated for three (3) amps and the transistor outputs are rated for 200 ma. OPERATING THE EMS CONTROLLER The EMS Controller is very simple to operate. Once the Setup numbers have been configured for your operation, the unit will automatically perform its duties with very little user interface. The front plate has three push-buttons for scrolling through information, changing set-points, and acknowledging alarms. See the Operating Instructions section for more information. PAGE 1 OF 24 TABLE OF CONTENTS CONTROL SEQUENCE OUTLINE .............e-.esaesnmeavonnacanneonncancareaaaanancaananoooeeo mane arre aean encarar ana acee. 3 SI. E-1-10101-1, (O a eee esse aaa r bbb anaans 3 LO -E-]1 10101 (1 - O sere a eee errr rerra aaa rarannns 4 SELECTOR SWITCH... PPPS PPPRUPU 4 TTS SOS SE0TES 6 START / STOP TYPE S IS 6 SL O 6 SERVICE REMIND ER SS rettet eeee eee eee eee eee eee e eee eteee ase rare ease eee estes aaah aes s see e ares senna abba bananas 6 SHUTDOWN TYPES ecececemenerrrerereneearrrrrrrr terre eerererrrrrrrr enn aceceneere rra see e eet eeeeaa eae ee essen sstan eee es 6 SPARE 1 TYPE SHUTDOWN _…........….…..……rrccrrssensenae rare een a anna ner aa sas eee eee eee ren nadaa nent eee nes N Eee En eee CCC ARE 6 UNIDO) E[ 200). AO 7 OPERATION DIRECTIONS -...........eeenenecnecconiononanaranennanenaccanaananaacaaaaneso nan anmananaan ete aemanmenancanEn Ene 8 OPERATING THE INTERFACE.................eeeeeeecec0ccceiiecee er ereeeeee e e rrreener eee e reba e eee eee e tease eae esse esas serene nbs nee e eee os 8 FIRST TIME EST = LLU 1 OPP PPP PPPRPPRRRI 8 MAIN DISPLAYS... OO UNUUURRRR 9 S-NUMBER DESCRIPTION AND LISTING...................eeeeeereeceniiereee eee er Renee rre cerecenececerereeeena non anrrrreceeeecee rene. 11 P-NUMBER DESCRIPTION AND LISTING...................éérsrrreeee eee resserre cesse ease essa masses ease enna 15 GENERAL WIRING PRECAUTIONS...................eeeeerecccorocicrceerer ie ercer recen rerererereneeennn or reneitrerecerceeerre ener. 19 DOUBLE CHECKING YOUR WIRING...................eeeeeeeeecrriiciirneneceer De erre e aci cecer rre rerrreeee recrean nece. 20 USER INTERFACE ..............ceconneccaccaannanonennaneanananencanetanenmanaancanaeusnananasananTEEE ao eenmm nen aaa anneoNececcaccananona 22 Customer wiring ......................ee..eeeeeireer ne e Recre PEO EN EN CNE 23 ENTRY CODE SUPPLEMENT..............eenmoncccenarnanonnenacenneneanannaan anna ncene cueca naa TE REE UNeenmene nen nee nacen anna. 24 7 NI [COS 24 P-NUMBERS TN ES 24 SN [EY] 21 3 TU PP PPPPPU ECS 24 SEQUENCE OF OPERATION CONTROL SEQUENCE OUTLINE START SEQUENCE With the TEST - OFF- AUTO selector in the "AUTO" position (this switch is mounted on the S449 relay board). Ifthere are no failures, [STATUS: SELECTOR -AUTO; STATE: PANEL READY]. If the start condition occurs, as determined by the user, refer to the start / stop types in the special feature section, the controller will initiate an auto start sequence [STATUS: AUTO START; STATE: DLY ON STRT] A. H. The controller has a DELAY ON START function. The controller will ignore the automatic start signal for the DELAY ON START time delay. If this function is not used set the delay to zero (0). The delay is field adjustable from zero (0) to three hundred (300) seconds. The controller has a PRELUBE function. The controller will prelube the engine for PRELUBE DELAY time period. If this function is not used set the delay to zero (0). The delay is field adjustable from zero (0) to three hundred (300) seconds. When the PRELUBE DELAY expires the following shutdown circuits are "ARMED" immediately (Names in parenthesis are actual names displayed), 1. HIGH DISCHARGE PRESSURE (HI DISCHARGE PSI). 2. OVERSPEED (OVERSPEED). 3. OVERCRANK (OVERCRANK). The fuel circuit is energized. The starter pilot relay is energized [STATUS: AUTO START; STATE: CRANK ON/OFF]. Cycle cranking begins: Crank 10 seconds; Rest 10 seconds until engine starts or OVERCRANK program operates. NOTE: CYCLE CRANKING. If the engine does not start on the first crank, the controller will de- energize the starter output for the entire rest cycle. NOTE: OVERCRANK. If the engine fails to start after the field-programmable number (preset to 6) of cranking attempts, OVERCRANK will be indicated on the alpha-numeric display. The Micro-controller Start Sequence will be halted and automatic control circuits will be locked out. The lockout must be manually reset before normal operation may be resumed. The MURPHYMATIC® Micro-controller will energize the ENGINE FAILURE status output. The "Fail" Status is reset by moving the panel selector switch to the "OFF" position. When the engine speed rises above the field-programmable Crank Disconnect speed setting, an automatic Run Sequence begins [STATUS: AUTO START; STATE: WARMUP TIMING]: 1. Cycle cranking is discontinued immediately. 2. Internal "hourmeter" program begins to record engine running hours. 3. The engine mounted throttle actuator is signaled to slowly increase the engine speed to the field programmable “WARMUP RPM.” 4. Three (3) timing periods begin: a) Shutdown Lockout time delay -- field-programmable period. Preset to thirty (30) seconds. NOTE: The second line of the display will show "SHUTDOWN DELAY TIMING" until the lockout delay expires. b) Warmup time delay -- field-programmable to 999 seconds. С) Minimum run delay -- field-programmable to 72.0 hours. Note: The Minimum Run timer is a standard feature included with the controller. If this function is not desired set the delay to zero (0). When the preset, Shutdown Lockout delay expires the following shutdown circuits are "armed:" (Names in parenthesis are actual names displayed): File Name: a97127op.doc Page 3 of 24 SEQUENCE OF OPERATION '“— LOW OIL PRESSURE (LO OIL PRESSURE). HIGH COOLANT TEMPERATURE (HIGH H20 TEMP). LOW COOLANT PRESSURE (LO H20 PRESSURE). HIGH PUMP TEMPERATURE (HI PUMP TEMP). LOSS OF SPEED (LOSS OF SIGNAL). BONA SHUTDOWNS When a SWICHGAGE® signals a malfunction, the appropriate Shutdown Name is shown on the second line of the display and the engine is signaled to shutdown immediately or to throttle back to a field-programmable shutdown RPM depending on type of shutdown assigned to that failure condition. The display will indicate cause of shutdown and the panel must be manually reset --selector moved to OFF position -- before normal operation may be resumed. The Micro-controller stores the Shutdown Name in the program set point memory for future reference. On any shutdown, the Engine Failure output is turned on. |. When the Warmup timing period expires [STATUS: AUTO START; STATE: AT LOAD]: 1. The Controller will signal the engine mounted throttle actuator to slowly increase the engine RPM to at least minimum RPM. It will throttle the engine Between the minimum and maximum RPM to maintain the MAINTAIN PSI set point. 2. At-load time delay begins timing. J. As the engine speed increases to the clutch engage RPM contacts will close to signal the clutch to engage. | К. When the At-Load time delay expires the following shutdowns are "armed:" (Names in parenthesis are actual names displayed): 1. LOW DISCHARGE PRESSURE (LO DISCHARGE PSI). 2. LOW SUCTION PRESSURE (LO SUCTION PSI). STOP SEQUENCE Il. If the stop condition occurs, as determined by the user, and the Minimum Run Timer has expired the controller will initiate an auto stop sequence [STATUS: AUTO STOP; STATE: DLY ON STOP]: A. The controller has a DELAY ON STOP function. The controller will ignore the automatic stop signal for the DELAY ON STOP time delay. If this function is not used set the delay to zero (0). The delay is field adjustable from zero (0) to three hundred (300) seconds. B. When the DELAY ON STOP delay expires: 1. the engine mounted throttle actuator is signal to slowly decrease the engine speed to the engine idle RPM. 2. The At-Load shutdowns are disarmed. C. As the speed decreases below the CLUTCH RELEASE RPM the contacts will open to signal the clutch to dis-engage. D. A field-programmable (0 - 999 seconds) Cooldown time delay period begins timing [STATUS: AUTO STOP; STATE: COOLDOWN TIMING]. When this delay expires: Internal "hourmeter" program stops recording and stores current engine running hours. All shutdown circuits are locked out. The solenoid fuel valve is de-energized. Control circuits automatically reset for next START sequence [STATUS: SELECTOR - AUTO; STATE: PANEL READY]. ON SELECTOR SWITCH It. The Control panel is equipped with a 3 position selector switch ... TEST -- OFF -- AUTO: TEST Automatic START and RUN sequences are initiated when selector is moved to the TEST position. The control panel will perform its operations as though an automatic start signal were accepted by the engine control panel. The engine will be kept in operation until the switch is moved to the OFF File Name: a971270p.doc Page 4 of 24 SEQUENCE OF OPERATION + position. If the switch is moved rapidly from the TEST position through the OFF position to the AUTO position the controller will initiate an auto stop sequence, if there is no auto start active. OFF Disconnects control power to prevent engine from starting or continuing to run through the control panel. Provides an immediate shutdown whenever the selector is placed in the OFF position while the engine is running in any other selector position. AUTO As described in above sequence outline. File Name: a97127op.doc Page 5 of 24 — SPECIALFEATURES — SPECIAL FEATURES START / STOP TYPES The Controller has a set point for selecting the type of automatic start / stop the controller will perform. This input can be configured through the Ss. Your choices include: CLOCK, PSI, REMOTE and CLK/PSI. If one type is selected the controller will ignore the other types. The following describes the start / stop types: CLOCK: When this is selected the controller will monitor the clock start / stop times. It will have the ability to start up to three times a day as programmed in the P#s. The start times are independently programmed for each day of the week. REMOTE: When the set point is set to REMOTE a start input must be present the entire time a run condition is required on terminal 1. When this input is taken away, the unit interprets this as a stop signal. PSI: If this set point is adjusted to PSI, the unit will start and stop based on the PSI START and PSI STOP set points set in S#s. CLKIPSI: If this set point is adjusted to CLK/PSI, the unit will start and stop based on the PSI START and PSI STOP set points set in S#s and the clock start times in the P#s. SITE START J When the controller is first set up at a site for operation, the operator can force a site start. This means, regardless of the automatic start selected the controller will start and run. It will throttle the engine to maintain the system pressure. It will run as long as the site start run time is programmed for. After the controller has completed this run time the controller will auto stop the engine and resume running in the auto sequence as programmed by the user. SERVICE REMINDERS The Controller will have field adjustable service reminders. The user can program the engine running hours for the controller to enunciate the service reminders. These service reminders could represent time to change the oil filter or air filter etc.. To clear the Service Reminder prompt simply go into the P#s described in the Operation section and acknowledge the Service Reminder. SHUTDOWN TYPES There is an S# for some of the shutdowns. This set-point lets you pick the way you want the controller to the shutdown. Your choices include: Immediate alarm only, Immediate alarm & Shutdown, Immediate alarm before shutdown, Delay alarm only, Delay alarm & shutdown, Delay alarm before shutdown and Low Suction Pressure. These types of shutdowns are self explanatory. An immediate type alarm, shutdown or both will be processed whenever the input is active. A delay type alarm, shutdown or both will be processed after the Lockout Delay has expired. The shutdowns or alarms will be recorded in the alarm / shutdown history. The following shutdowns’ types are field selectable: 1. Oil Pressure. 2. Coolant Temperature 3. Coolant Pressure 4. Spare 1 Shutdown The following shutdowns are fixed to be shutdowns only: 1. High Discharge Pressure 2. Low Discharge Pressure 3. High Pump Temperature SPARE 1 TYPE SHUTDOWN The Controller has a spare shutdown input. This input can be configured through the S#s. This set-point lets you pick the way you want the controller to handle an input on the spare 1 terminal. Your choices include: Immediate alarm only, Immediate alarm & Shutdown, Immediate alarm before shutdown, Delay alarm only, Delay alarm & shutdown, Delay alarm before shutdown and Low Suction Pressure. These types of shutdowns are self File Name: a97127op.doc Page 6 of 24 ~ SEQUENCE OF OPERATION explanatory. An immediate type alarm, shutdown or both will be processed whenever the input is active. A delay type alarm, shutdown or both will be processed after the Lockout Delay has expired. SHUTDOWN HISTORY The Controller stores the last ten (10) shutdowns that have occurred due to system malfunctions. This record can be found in the P#s. File Name: a971270p.doc Page 7 of 24 OPERATION DIRECTIONS Operation Directions OPER HE INTERF By using the three push-buttons and the liquid crystal display, you can make set-point changes, acknowledge alarms, and scroll through the display. The graphic below shows the display and push-buttons. The * 4. Y keys are membrane type push-buttons. The * button is best described as an Enter key. You can confirm a set-point and acknowledge alarms with this button. The A button is used for increasing a set-point or scrolling up the display. The Y button is used for decreasing a set-point or scrolling down the display. The 2 line dot-matrix liquid crystal display shows information pertinent to its current running mode. EMS Controller EMS CONTROLLER ENTER INCREMENT BACK A Y sono TO EXIT EXIT NEXT DECREMENT For example, if the unit receives a remote start signal, it will auto start the engine and display the current operation on the screen. These states include Crank On, Crank Off, Warm-up, Cooldown, etc. When the unit has brought the engine on stream, the display will scroll vertically through the engine vital signs. These include, Oil Pressure, Engine Temperature, Engine Speed, Running Hours, etc. FIRST TIME SETUP Before using the unit for the first time, it is necessary to configure all the set-points. To access the S-numbers (Setup numbers), use the following procedure: 9. Press the Y button until the title page appears. MURPHY CONTROL PROGRAM A97127 2. Now, press the € button once. This will bring up the entry code screen. 3. Next, press the AY buttons until the appropriate entry code is displayed. See the Secret Code Supplement for your number. 4, Finally, press the e button once. You are now able to edit the S-numbers. To change an S-number, the following procedure should be used. We will change the OVERSPEED set-point for this example. 5, Once you have accessed the S-numbers through the above procedure, the screen will show the following : 11-4 0000 S-1 LINE 1 SELECT Note: The top line may be different. Refer to S1 in S-Number Description And Listing section. 6. Now, press the Æ button six times to see the following screen: [1-4 0000 | S7 SET DAY OF WK File Name: a97127op.doc Page 8 of 24 ~ OPERATION DIRECTIONS 7. Next, press the © button once. This will bring up the following screen: (Note: The value in the DAY OF WEEK may vary). 11-4 0000 FRIDAY 8. Next, press the AY buttons until the appropriate value is displayed. For demonstration purposes, set the unit to WEDNESDAY. 11-4 0000 WEDNESDAY 9. Finally, press the e button once. You have now changed the day of the week to WEDNESDAY. All set-points are adjusted in the same manner as described above. The only difference is which S- number you select before scrolling the set-point change. Once you have adjusted each S-number, with the appropriate values, you must exit the S-number setup mode. To do this, hold the Y button until the following screen is displayed and then press the e button once. This will put the unit back into normal operation mode. If you forget to exit the S-numbers, the unit will exit for you after a pre- programmed amount of time. 11-4 0000 | S-0 CIRCLE = EXIT MAIN DISPLAYS During normal operation, the unit allows you to scroll through a number of informative front displays by using the A Vv buttons. A listing and explanation of each follows: 1. MURPHY CONTROL This is the first line of the title page. 2. PROGRAM A97127 This is the second line of the title page. It shows which program is installed in your unit. This information is helpful when calling for technical assistance. 3. DD MMM YYYY This line displays the present date. 4. HH:MM:SS This line shows the present time. 5. RUN HOURS: XXXX.X This is your on board hour meter. It digitally displays the number of hours your engine has run. All the service reminders are based on the elapse time on the hour meter. 6. RUN TIME: XX.X HR This line displays the amount of time remaining in the minimum run timer. This must display zero (0) before the controller will automatically stop the engine. 7. BATTERY XX.X VDC This displays your engine battery voltage. 8. ENG SPD XXXX RPM This displays the current engine RPM. Decisions to stop cranking and shutdown on overspeed / underspeed are based on this number. 9. DISCH PSI XXX This displays the current discharge pressure as sensed from a pressure transducer. Shutdowns based on pump pressure reference this number. 10. OIL PR XXX PSI This displays the current engine oil pressure as sensed from an electric gauge sender. Shutdowns based on oil pressure reference this number. File Name: a971270p.doc Page 9 of 24 OPERATION DIRECTIONS ——— 11. H20 TEMP XXX °F This displays the current engine jacket water temperature as sensed from an electric gauge sender. The unit will signal the engine to shutdown if this temperature reading exceeds the shutdown point selected. 12. XXXXXXXXXXXXXXXX There are two positions on the selector switch that are displayed on this line: SELECTOR IN AUTO, and SELECTOR IN OFF. When this window shows AUTO, your TEST - OFF - AUTO switch is in the AUTO position. When in AUTO, the unit is ready to start the engine. Depending on the type of start programmed in the controller by the user, when the controller is in AUTO this window shows CLOCK START, REMOTE, PSI START, CLK/PSI START and SITE START when an auto start sequence is initiated. When this window shows OFF, your TEST - OFF - AUTO switch is in the OFF position. The unit will not initiate an auto start with the switch in the OFF position. If the switch is moved to the OFF position while the engine is running, the unit will signal the engine to stop. When this window shows TEST START, your TEST - OFF - AUTO switch is in the TEST position. When the switch is flipped to TEST, the unit will start the engine as if a start signal had been received; regardless of the start / stop contacts. 13. ST: XXXXXXXXXX ST stands for STATE. This window shows what state your controller is in. These states include the following: NOT READY, PANEL READY, START DLY, PRELUBE, CRANK ON, CRANK OFF, RECRANK DLY, WARMUP, AT LOAD, SHUTDOWN, STOP DLY and COOLDOWN. NOT READY: This state occurs when the selector is in the OFF position. It means that the panel is not ready to run in Automatic mode. PANEL READY: This state occurs when the selector is in the AUTO position and no shutdowns have occurred. It means that the panel is ready to run in Automatic mode. START DLY: This state occurs when a start signal is sensed and the start delay is timing. The start signal must be present throughout this delay before the unit goes to the next state. PRELUBE: This state occurs after the Start Delay expires. During the Prelube state, the unit energizes the prelube circuit for the prelube delay time. CRANK ON: This state occurs after the Prelube Delay expires. During the Crank On state, the unit energizes the starter circuit and attempts to start the engine. CRANK OFF: This state occurs after the Crank On state if the unit senses that the engine has not started. During the Crank Off state, the unit removes power from the starter circuit to cool off the starter before another cranking attempt is made. RECRANK DLY: This state occurs if a false start occurs. A false start occurs when the engine speed rises above crank disconnect RPM and then drops back below. This delay will not allow the controller to re-engage the starter. The purpose is to allow the engine to stop moving before allowing the controller to re-engage the starter. This state can only occur during the lockout delay. WARMUP: This state occurs after the unit senses that the engine has started. During this state, the unit throttles the engine to the warm-up RPM and stays at this engine speed until the Warmup Delay expires. The Lockout Delay also begins timing when the Warmup State begins. AT LOAD: This state occurs after the Warmup state concludes. It can also occur if a start signal is received during the Cooldown state (see Cooldown below). When the At Load state first begins, the Generator regulator output is energized to enable the generator. STOP DLY: This state occurs when a stop signal is sensed and the stop delay is timing. The stop signal must be present throughout this delay before the unit goes to the next state. COOLDOWN: This state occurs after the Stop Delay has expired. During the Cooldown state, the unit throttles the engine to an idle. As the engine RPM passes through the Clutch Release RPM, the unit will deactivate the clutch circuit. If a start signal is received during the Cooldown state, the unit will switch to the At Load state and ignore the Warmup state. SHUTDOWN: This state occurs if a shutdown condition is detected. Reasons for shutdown include low oil pressure, high engine temperature, overspeed, etc. During this state, the engine is signaled to shutdown and all start signals are ignored until the state is reset by moving the selector to the OFF position and then back into AUTO or TEST. 14. CHG OIL XXX HRS This display shows the number of running hours remaining before the oil must be changed in the engine. 15. OIL FLT XXX HRS This display shows the number of running hours remaining before the oil filter on the engine must be changed. 16. FUEL FLT XXX HRS File Name: a97127op.doc Page 10 of 24 OPERATION DIRECTIONS — This display shows the number of running hours remaining before the fuel filter on the engine must be changed. 17. AIR CLNR XXX HRS This display shows the number of running hours remaining before the air cleaner on the engine must be serviced or changed. 18. SERV BAT XXXX HRS This display shows the number of running hours remaining before the engine cranking battery must be serviced or changed. S-NUMBER DESCRIPTION AND LISTING The S-numbers are used for customizing the controller to your specific application. Included in the S-numbers are the adjustable variables for the system. These S-Numbers must be set before trying to use the unit. Following is a list of available S-Numbers and a short description of the function of each. See Secret Code Supplement for the entry code number. S-0: Manual 'EXIT' from the S-number setup mode. Press " 'CIRCLE' TO EXIT" S-1: Line One Selection. Sets the variable to be displayed on the top line of the display while in the Setup Select mode. Available: RUN HOURS ENGINE SPEED LEAD SPEED SYSTEM VOLTAGE OIL PRESSURE ENGINE TEMPERATURE INPUT / OUTPUT STATUS Note: The input / output status information will show an X on an |/O if that particular input is or output is active. If there is no input or the output is OFF, the unit will display an O. This can be used for testing wiring before starting the engine. For more information, see the section titled “Double Checking Your Wiring”. | S-2: Set Time Minutes. To adjust the minutes portion of the Real Time Clock. S-3: Set Time Hours. To adjust the hours portion of the Real Time Clock. S-4: Set Date Day. To adjust the day portion of the date display. S-5: Set Date Month. To adjust the month. S-6: Set Date Year. To adjust the year. S-7: Set Day of Week. Adjusts day of week Sunday through Saturday. Day advances with date. S-8: SPEED CALIB: This setting is used to calibrate the speed signal so that the unit will display engine RPM. This setting must be adjusted for items such as crank stop RPM and OVERSPEED RPM to work. Simpiy enter the number of Pulses per revolution the magnetic pickup or alternator supplies to the unit . Another way to set this variable is to get the engine running at a known RPM and then change the number until the top line matches your known RPM. The resulting number is the pulses per revolution. Factory set to 208. 5-9: OVERSPEED: This setting allows you to enter the highest speed the engine can run before damage is caused. If the unit senses that the engine has exceeded this speed, it will signal the engine to shutdown. Factory set to 2000. S-10: LOCKOUT DELAY: This delay is used to ignore conditions such as low oil pressure when the engine first starts to allow the pressure time to reach its normal operating range (adjustable from 2 to 2,000 seconds). Factory set to 30. S-11: AT LOAD DLY: Set this variable to the amount of time you would like the Low Discharge Pressure shutdown ignored after warm-up. This allows the system to build discharge pressure with the engine AT LOAD before arming the shutdown. Factory set to 300. S-12: LOP @ LOW SPD: The EMS Controller gives you two oil pressure shutdown points. For engines File Name: a971270p.doc Page 11 of 24 OPERATION DIRECTIONS » —. that develop very little oil pressure at an idle, you put a lower shutdown setting in this set-point. The unit automatically changes the shutdown point between the Low Speed Shutdown point and the High Speed Shutdown point. Factory set to 15. S-13: LOP @ HI SPD: This set-point is the higher oil pressure shutdown point that is referred to in number 12 above. This is the point that you want the engine to shutdown during normal high speed engine operation. By shutting down the engine at a higher oil pressure, you can avert damage that could be caused by waiting to shut down the engine at the lower set-point needed to accommodate an idle. Factory set to 30. S-14: LO OIL PR TYPE: This set-point lets you pick the way the controller will handle an indication of low oil pressure. Your choices include: IMMEDIATE ALARM ONLY, IMMEDIATE ALARM AND SHUTDOWN, IMMEDIATE ALARM BEFORE SHUTDOWN, DELAY ALARM ONLY, DELAY ALARM & SHUTDOWN, DELAY ALARM BEFORE SHUTDOWN, LOW SUCTION PRES and OVERLOAD / UNDERLOAD. An immediate alarm is processed when the input is active. A delay alarm is processed after the lockout delay. Factory set to IMM ALM ONLY. S-15: LOP LO SPEED: Set this to your engine idle speed. If the engine is running at this speed, an idle for example, and the oil pressure reaches the value in the LOP @ LOW SPD set-point, the unit will initiate an automatic shutdown. Factory set to 600. S-16: LOP HI SPEED: Set this to your engine maximum speed. If the engine is running at this speed, and the oil pressure reaches the value in the LOP Q HI SPD set-point, the unit will initiate an automatic shutdown. Factory set to 1600. 40 35 30 25 20 15 10 > o 500 1200 1800 2400 The Graph above shows how the set-point changes between your high speed set-point and low speed set-point. As the engine speed increases, the unit automatically raises the oil pressure shutdown set-point along a straight line between the two set-points you entered. S-17: HI WATER TMP: Adjust this setting to the engine jacket water temperature you do not want to exceed. If the unit senses a temperature higher than this set-point, it will initiate an automatic shutdown. Factory set to 220. S-18: HI TEMP TYPE: This set-point lets you pick the way the controller will handle a high temperature indication. Your choices include: IMMEDIATE ALARM ONLY, IMMEDIATE ALARM AND SHUTDOWN, IMMEDIATE ALARM BEFORE SHUTDOWN, DELAY ALARM ONLY, DELAY ALARM & SHUTDOWN, DELAY ALARM BEFORE SHUTDOWN, LOW SUCTION PRES and OVERLOAD / UNDERLOAD. An immediate alarm is processed when the input is active. A delay alarm is processed after the lockout delay. Factory set to IMM ALM ONLY. S-19: H20 PSI TYPE: This set-point lets you pick the way the controller will handle an input on the low coolant pressure terminal. Your choices include: IMMEDIATE ALARM ONLY, IMMEDIATE ALARM AND SHUTDOWN, IMMEDIATE ALARM BEFORE SHUTDOWN, DELAY ALARM ONLY, DELAY ALARM & SHUTDOWN, DELAY ALARM BEFORE SHUTDOWN, LOW SUCTION PRES and OVERLOAD / UNDERLOAD. An immediate alarm is processed when the input is active. A delay alarm is processed after the lockout delay. Factory set to DLY ALM ONLY. S-20: WARMUP DLY: You can adjust this variable to the number of seconds you want your engine to warm-up before it engages the clutch and throttles up to an at load condition (adjustable from 1 to 300 seconds). Factory set to 30. S-21: COOLDOWN DLY: You can adjust this variable to the number of seconds you wish to cool down your engine before it shuts off after a stop signal is received (adjustable from 1 to 300 seconds). File Name: a971270p.doc Page 12 of 24 OPERATION DIRECTIONS Factory set to 60. S-22: PRELUBE DLY: If you have the requirement for prelube or possibly a glowplug, you can use this delay. Set in the number of seconds you wish the unit to turn on this output before it initiates a crank. Factory set to 1. S-23: ENG STRT DLY: Set this delay on engine start to the number of seconds that the start signal must be present before the unit accepts it and initiates an auto start sequence (adjustable from 1 to 300 seconds). Factory set to 1. S-24: ENG STOP DLY: Set this delay on engine stop to the number of seconds that the stop signal must be present before the unit accepts it and initiates a stop sequence (adjustable from 1 to 300 seconds). Factory set to 1. S-25: CRANK TIME: Set this delay to the desired amount of time you want each engine cranking attempt to last. Consult your engine manual for recommended cranking and resting times (adjustable from 1 to 300 seconds). Factory set to 10. S-26: REST TIME: Set this delay to the desired amount of time you want each rest period between cranking attempts to last. Consult your engine manual for recommended resting and cranking times (adjustable from 1 to 300 seconds). Factory set to 10. S-27: RECRANK DLY: This delay is used to adjust the amount of time the unit will wait for the engine to stop moving before attempting another crank if a false start occurs. A false start is when the engine starts but then dies before the LOCKOUT DELAY has expired (adjustable from 1 to 300 seconds). Factory set to 10. | S-28: CRK STOP RPM: This RPM set-point is used to adjust where the unit releases the starter during cranking. Set this to the RPM the engine attains just as it starts. This way, the starter is not engaged unnecessarily after the engine starts. You must also set this set-point to the speed you release the starter while cranking. This is how the unit senses whether the engine is running or not. You will get a NO SPEED SIGNAL shutdown if this is adjusted to high. Factory set to 300. S-29: CRK ATTEMPTS: Set the number of attempts you would like the controller to try an engine start. If the engine fails to start after the number of attempts you have selected, it will fail the engine and display OVERCRANK on the front display. This shutdown requires a manual reset. Factory set to 6. S-30: MIN ENG RPM: Minimum engine RPM is the speed at which your engine must run for its’ driven equipment to start performing work. For example, in a pumping application, minimum engine RPM is the speed the engine must run for the fluid to start being pumped. Set this variable to that value. Factory set to 900. S-31: MAX ENG RPM: Maximum engine RPM is the speed at which the engine driven pump performance peaks. If the engine exceeds this speed, pump performance deteriorate. This would be at the peak of the pump curve, for example. Set this set-point to that peak speed. For auto throttling at-load the controller will vary the engine speed between minimum and maximum RPM. Factory set to 1600. S-32: WARMUP SPEED: This is the engine RPM the controller will throttle the engine to during warm- up. Consult the engine manual for the optimum warm-up speed. Factory set to 700. S-33: RATE INC RPM: This set-point is used to customize how fast or slow the controller will increase the engine RPM while throttling. Experiment with this number until the proper throttling is achieved. Factory setto 10. S-34: RATE DEC RPM: This set-point is used to customize how fast or slow the controller will decrease the engine RPM while throttling. Experiment with this number until the proper throttling is achieved. Factory set to 10. S-35: CLUT ENG RPM: After warmup, the unit brings the engine up to at least minimum RPM. While it is throttling up, it passes through the clutch engage RPM and engages the clutch. Set this point to the RPM you would like the unit to automatically engage the clutch after warm up. Factory set to 900. File Name: a9/127op.doc Page 13 of 24 OPERATION DIRECTIONS S-36: CLUT REL RPM: During cooldown, the unit brings the engine to an idle. While it is throttling down, it passes through the clutch release RPM and drops out the clutch. Set this point to the RPM you would like the unit to automatically release the clutch during Cooldown. Factory set to 900. S-37: THR MIN PULS: This set-point is used to further customize the way controller will throttle the engine. Higher numbers cause the throttling outputs to stay active for longer periods of time when the system is throttling either up or down. If the engine is hunting then lower the value. If the engine never reaches the set-point then increase the value. Factory set to 700. S-38: THR FDBK DLY: This set-point is used to adjust the amount of time the controller waits to sample the change made by the previous throttle pulse. If the system pressure, for example takes a long time to change based on engine speed changes, this set-point should be increased. However, if the system pressure responds quickly then set the variable to a smaller value. Factory set to 2. S-39: THR SENSITVY: This set-point adjusts the throttler sensitivity when it closes in on the desired set-point. Higher numbers cause it to make more coarse signal adjustments when approaching a set-point than lower numbers. This set-point is used to keep the controller from overshooting and undershooting the a set-point. Lower the number if the controller is hunting. Raise the value if the unit doesn’t achieve the desired set-point. Factory set to 700. ————— S-40: SET ADJ DLY: This delay allows the controller to stop making adjustments to the engine RPM for this delay. It allows for a settling time after making a speed adjustment. Factory set to 2. S-41: SPARE 1 TYPE: This set-point lets you pick the way the controller will handle an input on the spare 1 terminal. Your choices include: IMMEDIATE ALARM ONLY, IMMEDIATE ALARM AND SHUTDOWN, IMMEDIATE ALARM BEFORE SHUTDOWN, DELAY ALARM ONLY, DELAY ALARM & SHUTDOWN, DELAY ALARM BEFORE SHUTDOWN, LOW SUCTION PRES and OVERLOAD / UNDERLOAD. An immediate alarm is processed when the input is active. A delay alarm is processed after the lockout delay. Factory set to DLY ALM & SHTDWN. S-42: CHANGE OIL: Set the interval in engine running hours you wish to be prompted to change your engine oil. Factory set to 500. S-43: CHG OIL FLTR: Set the interval in engine running hours you wish to be prompted to change your engine oil filter. Factory set to 500. S-44: CHG FUEL FLT: Set the interval in engine running hours you wish to be prompted to change your engine fuel filter. Factory set to 1000. S-45: SERV AIR CLN: Set the interval in engine running hours you wish to be prompted to service your engine air cleaner. Factory set to 10. S-46: SERV BATTERY: Set the interval in engine running hours you wish to be prompted to service your cranking battery. Factory set to 120. NOTE: After service reminder time values have been set, the new values will not take effect (become active) until they have also been acknowledged in the P-Numbers below. S-47: START/STOP: This set-point allows you to configure the type of automatic start / stop inputs the controller will use. The choices include CLOCK, PSI, REMOTE and CLK/PSI. Factory set to CLOCK. S-48: SITE START: This set point allows for the user to force a start that overrides any other start signal and run for the site run time period. Use the up arrow to switch the display from OFF to ON and the site start operation will begins. When the site run time expires the controller will initiate a stop sequence and the display will switch back to OFF. Factory set to OFF. S-49: SITE RUN: This set-point lets you set in the amount of time you would like your engine to run on a site start operation. Adjustable from 0.0 to 24.0 hours. Factory set to 0.0. S-50: START PSI: Set this to the pressure you would like the unit to initiate an auto start. Factory set to 40. S-51: STOP PSI: Set this to the pressure you would like the unit to initiate an auto stop. Factory set to File Name: a97127op.doc Page 14 of 24 ~ OPERATION DIRECTIONS ~~ 60. S-52: MAINTAIN PSI: Set this set-point to the discharge pressure you would like to maintain in the system while auto throttling. Factory set to 50. S-53: DEADBAND: Set this set-point to a plus / minus value that he controller will be satisfied that it has met the maintain pressure. This keeps the engine from hunting around a fixed pressure set- point. Factory set to +/- 2 PSI. S-54- DAMPING DLY: This delay is for the internal target RPM to start changing the engine speed . Factory set to 10. S-55: HIGH DISCH PSI: This set-point allows you to set an engine shutdown point on high discharge pressure. Factory set to 65. S-56: LOW DISCH PSI: This set-point allows you to set an engine shutdown point on low discharge pressure. Factory set to 25. S-57: PSI MAX: Set this to the maximum value of the transducer. For example, if the transducer is rated for 0 to 400 PSI then 400 should be entered. Factory set to 300. S-58: SET SLOPE: This helps with the calibration of the analog reading. To calibrate, power up the transducer, remove all pressure from the transducer and make the set-point match the raw count displayed on the top line. Factory set to 51. — ——— ¡— S-59: MIN RUN TIME: Set this variable to the minimum amount of time you would like the unit to run after receiving a start signal. A stop signal will be ignored until this time delay expires. This set- point is adjustable between 0.0 and 72.0 hours. If you do not want to use this feature, set it to 0.0. This variable is ignored when operating your start/stop off of the clock. Factory set to 0.0. ——— а — ля о P-NUMBER DESCRIPTION AND LISTING The EMS Controller has P-numbers in addition to the S-numbers you configured in the previous step. These are accessed in the same manner but using a different access code. See the Secret Code Supplement for this code number. P-0: Manual 'EXIT' from the S-number setup mode. Press " 'CIRCLE' TO EXIT" P-1: Line One Selection. Sets the variable to be displayed on the top line of the display while in the Setup Select mode. Available: | ENGINE SPEED RUN HOURS SYSTEM VOLTAGE OIL PRESSURE ENGINE TEMPERATURE P-2: SUN SEL: Set this to YES if you want to start your engine on SUNDAY. Set it to NO if you want to lock out the start time on this day. Factory set to NO. P-3: SUN A RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your first start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-4: SUN A HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-5: SUN A MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-6: SUN B RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your second start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-7: SUN B HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-8: SUN B MIN: This set-point lets you set the clock minute you would like to start. For example, if you File Name: a97127op.doc Page 15 of 24 ~~ OPERATION DIRECTIONS want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-9: SUN C RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your third start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-10: SUN C HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-11: SUN C MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-12: MON SEL: Set this to YES if you want to start your engine on MONDAY. Set it to NO if you want to lock out the start time on this day. Factory set to NO. P-13: MON A RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your first start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-14: MON A HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-15: MON A MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-16: MON B RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your second start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-17: MON B HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-18: MON B MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-19: MON C RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your third start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-20: MON C HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-21: MON C MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-22: TUE SEL: Set this to YES if you want to start your engine on TUESDAY. Set it to NO if you want to lock out the start time on this day. Factory set to NO. P-23: TUE A RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your first start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-24: TUE A HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-25: TUE À MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-26: TUE B RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your second start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-27: TUE B HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-28: TUE B MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. File Name: a971270p.doc Page 16 of 24 — OPERATIONDIRECTIONS — P-29: TUE C RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your third start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-30: TUE C HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-31: TUE C MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. | P-32: WED SEL: Set this to YES if you want to start your engine on WEDNESDAY. Set it to NO if you want to lock out the start time on this day. Factory set to NO. P-33: WED A RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your first start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-34: WED A HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-35: WED A MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-36: WED B RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your second start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-37: WED B HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, sett to 15. Factory set to 00. P-38: WED B MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-39: WED C RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your third start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-40: WED C HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-41: WED C MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-42: THR SEL: Set this to YES if you want to start your engine on THURSDAY. Set it to NO if you want to lock out the start time on this day. Factory set to NO. P-43: THU A RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your first start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-44: THU A HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. Р-45: THU A MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-46: THU B RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your second start time. You have three available start times per day (A, B, and C). Factory set to 0.0. Р-47: THU B HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-48: THU B MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-49: THU C RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your third start time. You have three available start times per day (A, B, and C). Factory set to 0.0. File Name: a97127op.doc | Раде 17 о? 24 _ OPERATION DIRECTIONS P-50: THU C HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-51: THU C MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-52: FRI SEL: Set this to YES if you want to start your engine on FRIDAY. Set it to NO if you want to lock out the start time on this day. Factory set to NO. P-53: FRI A RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your first start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-54: FRI A HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-55: FRI A MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-56: FRI B RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your second start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-57: FRI B HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, setit to 15. Factory set to 00. P-58: FRI B MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this-until it read 30 in the minute portion Factory set to 00. P-59: FRI C RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your third start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-60: FRI C HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, setit to 15. Factory set to 00. P-61: FRI C MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-62: SAT SEL: Set this to YES if you want to start your engine on SATURDAY. Set it to NO if you want to lock out the start time on this day. Factory set to NO. | P-63: SAT A RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your first start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-64: SAT A HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-65: SAT A MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-66: SAT B RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your second start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-67: SAT B HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. P-68: SAT B MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. P-69: SAT C RUN TM: This set-point lets you set in the amount of time you would like your engine to run on your third start time. You have three available start times per day (A, B, and C). Factory set to 0.0. P-70: SAT C HR:. This set-point lets you set the clock hour you would like to start. For example, if you want to start in the 3 o'clock in the afternoon hour, set it to 15. Factory set to 00. File Name: a97127op.doc Page 18 of 24 OPERATION DIRECTIONS P-71: SAT C MIN: This set-point lets you set the clock minute you would like to start. For example, if you want to start at 8:30 in the morning, you would adjust this until it read 30 in the minute portion Factory set to 00. Р-72: DSH PR @ SHDW: Shows what the discharge pressure was when the unit initiated the last failure shutdown. To view the information, press the © button. P-73: OIL PR @ SHDW: Shows what the engine oil pressure was when the unit initiated the last failure shutdown. To view the information, press the € button. P-74. TEMP @ SHDWN: Shows what the engine jacket water temperature was when the unit initiated the last failure shutdown. To view the information, press the © button. P-75: TACH @ SHDWN: Shows what the engine speed was when the unit initiated the last failure shutdown. To view the information, press the ® button. P-76: LAST SHUTDOWN: Shows what caused the last failure shutdown and the time in running hours that it occurred. To view the information, press the € button. P-77- tHith SHUTDWN: These P-numbers store the 2nd through the 10th cause of failure shutdown and the 85: running hours they occurred. To view the information, press the € button. P-86: ACK CHG OIL: This setting allows the user to acknowledge that he/she has changed the oil in the engine as prompted by the unit. When this setting is toggled from NO to YES, the unit resets the counter and will not prompt the user again until the selected number of running hours has elapsed. P-87: ACK OIL FLTR: This setting allows the user to acknowledge that he/she has changed the oil filter as prompted by the unit. When this setting is toggled from NO to YES, the unit resets the counter and wili not prompt the user again until the selected number of running hours has elapsed. P-88: ACK FUEL FLT: This setting allows the user to acknowledge that he/she has changed the fuel filter as prompted by the unit. When this setting is toggled from NO to YES, the unit resets the counter and will not prompt the user again until the selected number of running hours has elapsed. P-89: ACK AIR CLNR: This setting allows the user to acknowledge that he/she has changed or serviced the air cleaner as prompted by the unit. When this setting is toggled from NO to YES, the unit resets the counter and will not prompt the user again until the selected number of running hours has elapsed. P-90: ACK BATTERY: This setting allows the user to acknowledge that he/she has serviced / changed the battery as prompted by the unit. When this setting is toggled from NO to YES, the unit resets the counter and will not prompt the user again until the selected number of running hours has elapsed. P-91: PROGRAM £: The value in this window is the program and version number. This is helpful information to have before calling the factory for technical help. GENERAL WIRING PRECAUTIONS There are several precautions you can take on initial installation to reduce chances of failure over time. Many of these steps may take a few extra minutes to do at the time of installation; however, they can also save many headaches in the future. We strongly recommend that you follow these precautionary steps. 1. Suppression Diodes Place suppression diodes across all inductive loads. These loads typically include pilot relays, solenoid valves, starter solenoids, etc. This helps increase contact life and eliminate a source of electrical interference. 2. Wire power leads directly to battery Post. When hooking your power supply to your Test- Off - Auto switch (AUTOMATIC MODE) or OFF-ON switch (MANUAL MODE), run your wiring directly to the battery post. This helps minimize noise generated from battery chargers and alternators. 3. Pilot excessive loads. Many of the outputs on the EMS Controller are rated for low current, control type loads. Do not run high current loads directly to the unit. 4. Use stranded wire for hookup. Solid wire transmits vibration and is more likely to crystallize and break when it is subjected to movement. 5. Separate AC and DC wiring. File Name: a971270p.doc Page 19 of 24 OPERATION DIRECTIONS Never run AC and DC handling wiring together. AC signals may get coupled into the control circuits leading to erratic operation. 6. Wire standby battery charger directly to battery. Standby chargers must be wired directly to the battery. Failing to do this may result in erratic operation due to electronic "noise" coupled into the microprocessor. 7. Special precautions for spark ignition engines. Magnetos and ignition coils produce high voltage and cause high frequency interference. The EMS Controller is designed to filter out much of this interference; however, precautions must be taken to protect the unit. Sender and shutdown wiring must be routed away from the magneto and spark coil wiring. Resistor spark plugs and spark plug wires reduce electrical interference and may also be required in especially "noisy" environments. 8. Use shielded cable on magnetic pickup. Shielded cable is recommended for connecting the magnetic pickup to the EMS Controller. This helps prevent signal loss and the possible coupling of electrical interference into the relatively sensitive speed sensing circuit. The shield should only be grounded on one end. Remember, proper care during installation will help your EMS Controller live a long and trouble-free operating life. If for any reason you have questions during installation, feel free to give us a call. DOUBLE CHECKING YOUR WIRING The EMS Controller has built in diagnostic information for confirming your wiring before you attempt to auto start your engine. The diagnostic information is found in the S-numbers under S1 LINE 1 SELECT. The factory default line 1 display shows the engine RPM. By scrolling through the displays, you will see the following: 11-4 00XO0 ENTER SELECTION This represents the 4 standard digital only inputs. An O means that the input is not active. An X means that the input is active. AUTO POSITION ON TOGGLE SWITCH TEST POSITION ON TOGGLE SWITCH EXTERNAL SPARE 1 SHUTDOWN INPUT NOT USED FOR THIS APPLICATION Бо № > The next screen shows the rest of your inputs: 15-12 OOXO 0000 ENTER SELECTION BATTERY VOLTAGE INPUT (IGNORE) WATER TEMPERATURE SENDER (For test purposes, you can ground this input to make sure you have run your wire properly.) 7. OIL PRESSURE SENDER For test purposes, you can ground this input to make sure you have run your wire properly.) 8. LOW COOLANT PRESSURE INPUT 9. REMOTE START/STOP 10. PUMP TEMPERATURE INPUT 11. PRESSURE TRANSDUCER Input. 12. SPARE ANALOG INPUT Da The next screen shows the state of your outputs: 01- 07 00X0 000 ENTER SELECTION File Name: a97127op.doc Page 20 of 24 ~~ OPERATIONDIRECTIONS — FUEL VALVE OUTPUT STARTER CIRCUIT OUTPUT COMMON FAIL OUTPUT THROTTLE DECREASE OUTPUT THROTTLE INCREASE OUTPUT PRELUBE OUTPUT CLUTCH OUTPUT м О о КО № :- File Name: a971270p.doc Page 21 of 24 USER INTERFACE User Interface The EMS448 controller has a user interface board, S449 module, for making the connections to the controller. Refer to bulletin EMS-94132N for more information on the user interface. The following chart is a description of the i/o layout for the EMS448. PIN RELAY | HARDWARE PROGRAM PIN ASSIGNMENT ASSIGNMENT 31 Analog 4 Remote Start/Stop 33 Analog 0 Battery Monitor ( No customer hookup) 35 Analog 7 Spare Analog Input 37 Analog 1 Electric Sender for Engine Water Temperature (from ES2T-250) 39 Input 1 Auto Position 11 Input 2 Test Position COM 1=B+ NO=8 NC=7 K6 Output 1 Fuel Solenoid Output COM 2=18 NO=16 NC=17 20 Battery + Battery Plus COM 1=6 NO=4 NC=5 K2 Output 2 Starter output COM 2=15 NO=13 NC=14 9&10 Battery - Ground NO = 21 & 22 K1 Output 3 Common Fail Output 1 Frequency Input Frequency Input (from MP3298) 32 Analog 6 Discharge Pressure input (4-20 ma from PXM-300) 34 Analog 5 Pump Temperature (from Contact closure to ground) 36 Analog 3 Coolant Pressure (from 20P-30) 38 Analog 2 Electric Gauge Sender for Engine Oil Pressure (from ES2P-100) 40 Input 3 External Spare 1 Shutdown 12 Input 4 Not Available for this application 23 Output 4 Throttle Decrease 25 Output 5 Throttle Increase NO = 27 & 28 KS Output 6 Prelube Output NO = 29 & 30 K7 Output 7 Clutch Output 2 RS485 - RS485 (-) 3 RS485 + RS485(+) File Name: a97127op.doc Page 22 of 24 AUXILARY CRANKING CRANKING IDLE-BACK CONTACTS CONTACTS CONTACTS 00056600600006666660066 TERMINAL BLOCK IN EMS448 PROGRAM NUMBER A97127 99900000 © STARTER ASSEMBLY FACTORY RECOMMENDS 12 AWG STRANDED WIRE | ur] € TERMINALS IN AT-67207 THROTTLE ACTUATOR 00906] uw a = REMOTE PRELUB = = FAILURE CIRCUIT, w INDICATION (3 AMP) 3 (3 AMP) — N CLUTCH CIRCUIT. (3 AMP) SOLENOID = FUEL VALVE NL UY N REMOTE START/STOP UU | A A RED WIRE Nu, PUMP — A TEMPERATURE SHIELDED ALTERNATOR | XxX EXCITATION (1 AMP 7 E9 E9 6) SPARE | SHUTDOWN COOLANT PRESSURE COOLANT TEMPERATURE SENDER (ES2T—250") OIL PRESSURE SENDER (ES2P—1004) PXMS—300 PRESSURE TRANSDUCER 1 AMP MAGNETIC PICKUP (MP3298) 5+ 12 OR 24 BATTERY FACTORY RECOMMENDS 12 AWG STRANDED WIRE NOTES: AFTER THE AT—67207 THROTTLE ACTUATOR HAS BEEN INSTALLED, THE "SLOW” AND "FAST” CONTROL TERMINALS MUST BE DETERMINED. THE DIRECTION OF CONTROL ARM MOVEMENT SHOULD BE OBSERVED AS FOLLOWS, > TO MOVE TOWARD THE FULL IDLE POSITION. > TO MOVE TOWARD THE FULL SPEED POSITION. Murphy Switch of California, Inc. Р.О. BOX 900788; PALMDALE, CA 93590 PHONE: (805) 272-4700 FAX: (805) 947-7570 € moro TITLE MCM 10/30/98 CUSTOMER WIRING DRAWING FOR MURPHYMATIC EMS448 OR 447 USING 449 RELAY BOARD PROGRAM #A97127 C N POWER REF.: EAST BAY MUNICIPAL UTILITY DISTRICT DRAWN Mark Mahoney DATE 9/11/97 SCALE NONE DRAWING NO. 40—97—127—B FILE NO. A97127B.DWG ">
/
Изтегляне
Само приятелско напомняне. Можете да видите документа точно тук. Но най-важното е, че нашият AI вече го е прочел. Той може да обясни сложни неща на прост език, да отговори на вашите въпроси на всеки език и да ви помогне бързо да навигирате дори в най-дългите или най-сложните документи.
Реклама