FD2452E

D/N Megapixel 360° Panorama Dome IP Camera

Quick Installation Guide

CAUTION

Do not drop or strike this equipment

Do not install the equipment near any naked flames or heat sources

Do not expose this unit to rain, moisture, smoke or dust environment

Do not cover the opening of the cabinet with cloth and plastic or to install this unit in poor ventilated places. Allow

10cm between this unit and its surroundings

Do not continue to operate the unit under abnormal conditions such as detection of smoke, strange smell or no display on screen while power is turned on

Do not touch the power connection with wet hands

Do not damage the power cord or leave it under pressure

Do not operate this unit near magnet, speaker system, etc., to avoid unnecessary magnetic interference

Connection cables should be grounded properly

Product Overview

Alarm In/Out Terminal

Audio Input 3.5mm Phone Jack (Red)

Audio Output 3.5mm Phone Jack (Green)

Live Video Output BNC Jack

RJ-45 Network Connector (Support PoE)

DC Power Input Jack (DC12V ±10%)

Top Cover

Micro SD CARD SLOT (Support SD/SDHC)

Reset Key

To restore the server to factory default setting.

Lens

Light Sensor

Microphone

- 1 -

Unit: mm

Installation

Installation Structural Drawing

Embedded Mounting Attached Mounting

(Ceiling base is optional)

- 2 -

Embedded Mounting (False Ceiling)

1. Please use the screw driver to untighten the screws on the top cover (FIG. 1), and to untighten the screws on the cylinder (FIG. 2).

2. Based on the hole site diagram below to cut the circle of diameter

3.6-4.1 inches (90-105mm) (FIG.3, FIG. 4, FIG. 5).

3. Connect the network cable to RJ-45 network port and connect power cable to DC power input jack of the IP camera (FIG.6)

- 3 -

4. Attach the camera body to the fixed ring (FIG. 7). Tighten the screws to fix the camera body (FIG. 8).

5. Put the decorative ring on the camera body. Ring’s positioning column should be between camera body positioning column and screw nut (FIG. 9). Rotate the decorative ring counter clockwise until its position column touch the camera body positioning column. Tighten the 4 screws (FIG. 10).

- 4 -

Attached Mounting (Fixed Ceiling)

1. Camera base size and screw location (FIG.11),and tighten the four tapping screws into the ceiling (FIG.12).

2.

The fixed ring placed on the base (FIG.13). Tighten the four screws into the base (FIG. 14).

3. Connect the network cable to RJ-45 network port and connect power cable to DC power input jack of the IP camera (FIG.15)

- 5 -

4. Attach the camera body to the fixed ring. Camera body screw hole should be aligning to fixed ring’s latch position (FIG.16). Tighten the two screws to fix the camera body (FIG.17).

5. Put the decorative ring on the camera body. Ring’s positioning column should be between camera body positioning column and screw nut (FIG.18). Rotate the decorative ring counter clockwise until its position column touch the camera body positioning column. Tighten the 4 screws (FIG.19).

- 6 -

System Architectures

For connecting HD IP cameras to the network, please follow one of the system architectures:

(1). Use a DC12V power adapter and a network switch to connect to the network.

(2). Use a PoE network switch to connect to the network.

(3). Use a PoE power injector and a network switch to connect to the network.

- 7 -

Emergency Factory Default

To restore factory default settings by hardware, please follow these steps:

1. Hold “RESET Key” for 10 seconds, then release.

2. After about 40 seconds, the network LED light should turn off, and the back on again.

3. This camera has completed the factory default settings, and can then reboot.

4. Search for the IP device using the IPScan software.

5. Start the IP device via Internet browser.

6. Enter the default username “admin” and password “pass” to operate.

NOTE: For user convenience, restoring the factory default settings will revert to the default IP address 192.168.0.200.

Before Accessing IP Cameras

Before accessing the IP camera, make sure that the camera’s RJ-45 network, audio, and power cables are properly connected. To set the

IP address, consult your network administrator for an available IP address. The default IP address for each IP camera is 192.168.0.200.

Users can use the default IP address for verifying the camera’s network connection.

Software Requirements

Merit LILIN Universal ActiveX software components are required for web interface display of JPEG or H.264 Full HD video. When you login to the IP camera by Internet Explorer, the security warning dialog box will prompt the installation of the LILIN Universal ActiveX.

Click Install to download it.

- 8 -

Configuring IP Addresses by IPScan Software

To configure an IP address using the IP scan tool, you can copy the

IPScan software from the installation CD, and paste to your computer. Alternatively, you can execute the IPScan software from the installation CD, or download the software from the Merit LILIN website (www.meritlilin.com). To change the settings of the IP address, subnet mask, gateway, or HTTP port, you can follow the steps below:

1. Run the IPScan software.

2. Click Refresh. All available devices should be listed in the device list.

3. Select your device from the list provided.

4. Change the IP address, subnet mask, gateway, or HTTP port for the IP camera.

5. Click Apply to submit the settings.

6. Click Refresh to verify the settings.

- 9 -

Configuring IP Addresses via Web Interface

To change an IP address via web interface, type the default IP address (192.168.0.200) in the Internet browser and follow the steps below:

1. Login to the H.264 Full HD IP camera by the default username

“admin” and default password “pass”

2. Click Basic Mode configuration hyperlink.

3. Click Network->General hyperlink.

4. Change the IP address, subnet mask, gateway, or HTTP port for the IP camera.

5. Click Submit to verify the settings.

Internet Browser Settings & Application Required

Make sure your Internet browser allows the signed ActiveX plug-in to work on your computer. Set “Download Signed ActiveX plug-in controls” to “Prompt” and “Run ActiveX control and plug-in” to

“Enable”. You can set this option via Internet Explorer-> Tools->

Options-> Security Settings.

- 10 -

Once complete, you can access the IP camera’s live video by entering the default IP address via your Internet browser. As the security warning dialog box appears, click OK to download the ActiveX directly from the IP camera.

Login

There are two levels of user authentication, including admin and guest, that can access the IP camera. Administrator is authorized to reset basic mode settings and see live video, while the guest is allowed to see only live video.

The default usernames and passwords are as follows:

Username

Password

Administrator admin pass

Viewer guest guest

To logon the H.264 FULL HD IP camera, please type username and password in logon HTML page and click on Submit button to enter the system.

- 11 -

66-IPD2452CSM

IPD2542ES

D/N Megapixel 360° Panorama Dome IP Camera

Quick Installation Guide

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement