Angelcare AC601 Owner's Manual
Add to My manuals13 Pages
Angelcare AC601 is a simplicity movement sensor with sound baby monitor that provides peace of mind for parents by monitoring your baby's movement and sound. It features a movement alarm, voice-activated sound transmission, adjustable microphone sensitivity, and a rechargeable battery for the parent unit. The monitor also includes a cord cover kit for the sensor pad cord to ensure the safety of your baby. With its easy setup and reliable performance, the Angelcare AC601 helps you keep an eye on your baby while giving you the freedom to move around the house.
advertisement
for your peace of mind
OWNER’S MANUAL
SIMPLICITY MOVEMENT SENSOR
WITH SOUND BABY MONITOR
Model AC601
DON’T
FORGET
IMPORTANT ADVICE FOR INITIAL SETUP
Movement Alarm
Your monitor comes with the movement alarm activated.
When switching on your monitor it will alarm, with or without the Sensor Pad plugged in, if no movement is detected.
Deactivate the movement function to use the monitor without the Sensor Pad.
Batteries
Insert the enclosed rechargeable batteries into the Parent
Unit. If inserted incorrectly the Parent Unit will not charge when placed in the charging cradle. The charging indicator lights will flash to indicate charging.
Cord Safety
Ensure the Nursery Unit is at least 1 metre away from your baby’s cot. The Sensor Pad cord must always be kept out of reach of baby and secured using the cord cover kit provided.
Voice-activated Sound Transmission
Your monitor will transmit when it detects sound from your baby or in their room. You can adjust the microphone sensitivity to suit your needs.
PLEASE FOLLOW THE INSTRUCTIONS CAREFULLY FOR CORRECT SETUP
Please DO NOT return this product to the store. For assistance please contact our helpline on 0845 009 1789 or email [email protected]
Mon – Fri 10am – 4pm, excluding bank holidays.
TABLE OF CONTENT
WARNING .................................................................................... 3
AC601 SETUP REQUIREMENTS .................................................... 7
STEP 1 - Charging the Parent Unit (15 hours) .......................... 8
STEP 2 - Installing the sensor pad ............................................ 10
STEP 3 - Setting up the nursery unit .........................................13
STEP 4 - Turning on your monitor ..............................................14
STEP 5 - Testing and getting to know your monitor ............15
Troubleshooting ................................................................................18
Limited warranty ...............................................................................19
Technical specifications .................................................................20
OWNER’S MANUAL
KEEP YOUR OWNER’S MANUAL FOR FUTURE REFERENCE.
PLEASE READ THE WARNINGS AND INSTRUCTIONS CAREFULLY BEFORE
ASSEMBLING & USING THE PRODUCT.
FAILURE TO FOLLOW THE WARNINGS AND THE INSTRUCTIONS COULD RESULT
IN SERIOUS INJURY OR DEATH OR DAMAGES TO THE PRODUCT.
THE SENSOR PAD FEATURE IS NOT FOR USE WITH ADULTS, CHILDREN OR INFANTS
OLDER THAN 24 MONTHS.
THE SENSOR PAD IS NOT INTENDED TO BE USED TO DETERMINE IF A CHILD IS OUT
OF THE CRIB.
WARNING
Adult assembly required.
Keep small parts away from children when assembling.
2
This Angelcare Monitor is a Personal Care Product. Please DO NOT return this to the store where you purchased it from. If you have any questions or require assistance please call the
Angelcare Helpline on 0845 009 1789 or email [email protected].
The Baby Helpline is open Monday to Friday, 10am to 4pm. The helpline is closed on bank holidays.
For additional FAQs and to download instruction manuals visit; www.angelcare.co.uk.
To order spare parts for your Angelcare Baby Monitor visit; www.megababy.co.uk.
UK0514
WARNING
1. THIS PRODUCT CANNOT REPLACE
RESPONSIBLE ADULT SUPERVISION. This product is designed to aid in the monitoring of your child. When using the monitor, you must still provide the supervision necessary for the continued safety of your child.
Monitoring of premature babies, or those considered to be at risk, should always be carried out under the supervision of a health professional. This monitor SHOULD
NOT be used as a medical device, nor as a device to prevent Sudden Infant Death
Syndrome (SIDS).
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
DO NOT EXPOSE TO RAIN OR MOISTURE
8. Keep monitor AWAY from heat sources
(such as stoves, radiators, etc.).
2. WARNING Strangulation Hazard —
Children have been STRANGLED in cords.
Keep adapter cords out of the reach of children (more than 1 m away). NEVER use
Sensor Pad without the protective cord c o v e r i n g . C h e c k p r o t e c t i v e c o r d covering before each use. Immediately discontinue use of Sensor
Pad if protective covering is damaged or broken.
9. ALWAYS place both the Nursery Unit and
Parent Unit on a flat surface in an upright position and allow for proper ventilation.
DO NOT place on sofas, cushions, beds, etc. which may block ventilation.
10. This monitor uses public airwaves to transmit signals. The Parent Unit may pick up signals or interference from other nursery monitors in your area. Your monitor may even be picked up by other households. To protect your privacy, make sure both units are turned OFF when not in use. If you experience interference, change the channel on both units.
11. This product is NOT a toy. DO NOT allow children to play with it.
3. Never use extension cords with AC adapters. ONLY use the AC adapters provided.
12. This product contains small parts. Adult assembly required. Exercise care when unpacking and assembling the product and keep small parts away from children.
13. When using the monitor, the room temperature should be between 10 °C and 40 °C.
4. When an AC Adapter is plugged into an electrical outlet, DO NOT touch the exposed end.
5. ALWAYS be sure that both the transmitter and receiver are working properly and are within range of each other. Test monitor before first use, periodically and when changing location of the Nursery Unit.
6. ALWAYS be sure to immediately check on baby whenever an alarm sounds.
7. DO NOT use monitor near water (such as bath tub, sink, etc.).
BATTERY WARNING
14. Use ONLY A A A RECHARGE ABLE batteries for the Parent Unit. DO NOT mix old and new batteries. DO NOT mix alkaline, standard or rechargeable batteries. Insert batteries with correct polarity. DO NOT short-circuit supply terminals. ONLY use the recommended batteries or equivalent (volts and size) and the correct adapter. Remove batteries when product is stored for long periods of time or when batteries are exhausted.
Dispose exhausted batteries properly. DO
NOT recharge non-rechargeable batteries.
Rechargeable batteries are ONLY to be charged under adult supervision. Keep all batteries away from children.
3
4
15. IMPORTANT SAFETY INSTRUCTIONS
15.1 Read these instructions - All the safety instructions should be read before the product is operated.
15.2 Keep these instructions. The safety and operating instructions should be retained for future reference.
15.3 Heed all warnings – All warnings on the product and in the operating instructions should be adhered to.
15.4 Follow all instructions – All operating and use instructions should be followed.
15.10 Accessories - Only use attachments/ accessories specified by the manufacturer.
DO NOT place this product on an unstable cart, stand, tripod, bracket or table. The product may fall, causing serious injury to a child or adult and serious damage to the product. Use ONLY with a cart, stand, tripod, bracket or table recommended by the manufacturer or sold with the product.
Any mounting of the product should follow the manufacturer’s instructions.
15.11 Unplug this appliance during lightning storms or when not used for long periods of time.
15.5 Water and moisture - DO NOT use this apparatus near water. For example, near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet environment or near a swimming pool and the like. Care should be taken so that objects DO NOT fall onto units and that liquids are not spilled into either unit or Sensor Pad through its openings.
15.6 Cleaning - Disconnect all units before cleaning. DO NOT immerse in water any part of the Nursery Unit, Parent Unit. Clean only with dry cloth. DO NOT spray with cleaning products or solvents. Wipe Sensor
Pad with a cloth moistened very slightly with an antiseptic or mild detergent.
15.12 Servicing - DO NOT attempt to service this product yourself as opening or removing covers (except battery doors) may expose you to dangerous voltage or other hazards.
15.13 R e p l a c e m e n t p a r t s - W h e n replacement parts are required, be sure the replacement parts specified by the manufacturer have the same characteristic a s th e o rigin a l p a r t . U n a uth o rize d substitution may result in fire, electric shock or other hazards.
15.7 Ventilation - DO NOT block any ventilation openings. Allow for proper ventilation when units are in use. DO NOT cover the Nursery Unit or Parent Unit with any object such as a blanket. DO NOT place it in a drawer or in any location which would muffle the sound or interfere with the normal flow of air.
15.8 Heat sources - DO NOT install near any heat sources such as radiators, heat registers, stoves, TVs or other apparatus
(including amplifiers) that produce heat.
Heat can damage the case or electrical parts.
15.14 Usage - This baby monitor is intended as an aid. It is NOT a substitute for responsible and proper adult supervision and should not be used as such. Use this appliance ONLY for its intended use as described in this manual.
15.15 Power Sources - O perate this product only from the type of power source indicated on the type plate of the adaptor.
If you are unsure of the type of power supply to your home, consult your dealer or local power company.
15.16 Overloading - DO NOT overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire or electric shock.
15.9 Power cord protection - Protect the
Sensor Pad cord and Adapter’s power cord from being walked on or pinched by furniture or other items – Power supply cords should be routed so that they are not likely to be walked on or pinched by items upon or against them, paying particular attention to cords and plugs, convenience receptacle, and the point where they exit from the product.
15.17 Object and Liquid Entry - NEVER push objects of any kind into this product through casing slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. NEVER spill liquid of any kind on the product.
15.18 Antenna - The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter.
15.19 Power Lines - An outside antenna system should NOT be located in the vicinity of overhead power lines or other electric light or power circuit, or where it can fall into such power lines or circuits as contact with them may be fatal.
a stationary sleeping environment such as a crib where the Sensor Pad can rest on a completely flat, firm surface.
16. IMPORTANT SAFETY INSTRUCTIONS
RELATED TO USE OF BATTERIES
15.20 WARNING Strangulation Hazard
— Children have been STRANGLED in cords. Keep adapter cords out of the r e a c h o f c h i l d r e n
(more than 1 m away)
NEVER use Sensor Pad without the protective cord covering. Check p r o t e c t i v e c o r d covering before each u s e . I m m e d i a t e l y discontinue use of Sensor Pad if protective
16.1 Use ONLY the type and size of batteries specified in the owner’s manual.
There is a risk of explosion if batteries are replaced with an incorrect type.
16.2 U s e O N LY A A A r e c h a r g e a b l e batteries and/or the AC Adapters provided for the Parent Unit. You must use only rechargeable batteries in the Parent Unit.
DO NOT use alkaline batteries or you will severely damage the unit.
covering is damaged or broken.
15.21 Interference - This monitor uses public airwaves to transmit signals. The Parent
Unit may pick up signals or interference from other nursery monitors in your area.
Your monitor may even be picked up by other households. To protect your privacy, make sure both units are turned OFF when not in use. If you experience interference, change the channel on both units.
16.3 Charge the batteries for 15 hours prior to first use. Be sure to have the monitor in the OFF position during this period. ONLY use the AC Adapters included with your monitor.
16.4 DO NOT use these adapters with any other equipments.
16.5 When unplugging the AC Adapter from the Nursery Unit, be sure it is switched to the OFF position. If it isn’t, the unit will revert to battery mode if batteries are installed.
15.22 Vibration Source - When the monitor is in use, DO NOT use a crib mobile or other crib accessories that may produce vibrations. Other sources of vibrations may include fans, washing machines, loud music, etc. These sources of vibration may interfere with the performance of your
Angelcare ® monitor and the alarm will not sound if it continues to detect any movement other than your baby’s. Be sure all vibration sources are eliminated before using the monitor.
16.6 DO NOT use rechargeable batteries in the Nursery Unit. Use alkaline batteries
ONLY.
16.7 DO NOT dispose batteries in fire. They may explode. Check with local regulations for possible special disposal instructions.
You may experience false alarms for several reasons. The most common reason is the
Nursery Unit has not been turned OFF after you have removed your baby from the crib.
Another reason is the Sensor Pad has not been placed under the mattress properly.
16.8 Exercise care in handling batteries in order not to short out the batteries with conducting materials such as rings, bracelets and keys. Overcharging, short circuiting, reverse charging, mutilation, or incineration of batteries must be avoided to prevent one or more of the following occurrences: release of toxic materials, release of hydrogen and/or oxygen gas, rise in surface temperature.
Be sure the Sensor Pad is on a flat, firm surface with the printed side facing up.
The sensitivity level may also need to be adjusted. Refer to step 5.3. Always be sure to immediately check on baby whenever an alarm sounds.
16.9 DO NOT attempt to recharge batteries provided with or identified for use with this product that are not intended to be charged. The batteries may leak corrosive electrolyte or explode.
15.23 Sensor Pad - If the crib has a spring or slat base, place a hard board between the crib base and the Sensor Pad measuring at least 33 x 33 cm and 6 mm thick. Only use your Angelcare ® monitor in
5
16.10 DO NOT attempt to rejuvenate the batteries provided with or identified for use with this product by heating them.
Sudden release of battery electrolyte may occur, causing burns or irritation to eyes or skin.
16.11 If and when necessary, the batteries must be replaced with identical new ones or equivalent (volts and size). If a battery to be replaced is connected with other batteries in series, replace the other batteries at the same time as well. DO
NOT mix old and new batteries.
16.12 Reverse polarity installation of the batteries in the end product must be avoided. Reverse insertion of batteries can cause charging, and that may result in leakage or explosion.
16.13 Remove batteries from this product if you store the product over 30 days because the batteries could leak and damage the product.
16.14 Discard ‘dead’ batteries as soon as possible since ‘dead’ batteries are more likely to leak in a product. If a battery has leaked or vented, it should be replaced immediately using protective gloves.
17.2 NOTE: This equipment has been tested and found to comply with Part 15 of the
FCC Rules and the Industry Canada licenceexempt RSS standard. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
17.3 However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
16.15 DO NOT store this product, or the batteries provided with or identified for use with this product, in high-temperature areas.
17.4 This device complies with part 15 of the
FCC Rules and the Industry Canada licenceexempt RSS standard. Operation is sujected to the folowing two conditions:
WARNING
(North America Only)
17.1 Modifications not authorized by the manufacturer may void users authority to operate this device.
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
6
FCC AND IC REGULATIONS
RF radiation exposure statement
The Nursery Unit complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. Caution: To maintain the compliance with the FCC’s RF exposure guideline, install the Nursery Unit at least 20 cm from ALL persons. The transmitter of this device must not be co-located or operating in conjunction with any other antenna or transmitter.
Industry Canada
This product meets the applicable Industry Canada technical specifications.
CAN ICES-3 (B)/NMB-3 (B)
SETUP REQUIREMENTS
INCLUDED:
MOVEMENT SENSOR
WITH SOUND MONITOR
Model AC601
6 5
4
3 2 1
Parent Unit Nursery Unit
1 Sensor Pad (AC601) with pre-installed cord covers
2X
2 AC Adapters
YOU MUST PREPARE:
One hardboard (not included)
Thickness: 6 mm
Minimum dimensions:
33 cm x 33 cm
Maximum dimensions: equal to the mattress size
Hardboard
IMPORTANT
The hardboard must be larger than the Sensor Pad surface area.
3X
3 Rechargeable AAA Batteries
WHAT YOU WILL NEED (NOT INCLUDED):
Miniature Phillips
Screwdriver
4X
4 Alkaline
AAA Batteries
BABY’S ROOM:
IMPORTANT
Place the crib near a supporting wall and far from air currents. Install the Nursery
Unit on a flat, stable surface facing the crib at a distance of at least 1 meter.
Sensor Pad
6
5
4
IMPORTANT
Keep at least
1 m apart
3 2 1
7
8
STEP 1 - CHARGING THE PARENT UNIT (15 HOURS)
1
IMPORTANT
Never use regular alkaline batteries in the Parent Unit; they may explode.
2 3
15
1) Remove the battery cover and insert the Rechargeable Batteries (included).
2) Connect the AC Adapter to the Parent
Unit and into an electrical outlet.
3) Charge the unit for 15 continuous
hours (prior to first use).
NOTE:
To optimize your battery performance please refer to Battery Guidelines in the Trouble Shooting section.
1.1 - BATTERIES
HOW TO CHECK THE BATTERIES:
Unplug the AC Adapters from both units.
• If the Nursery or the Parent Unit
Power Indicator does not light up, replace the batteries.
The Power/Low
Battery Indicator
PARENT UNIT LOW BATTERY ALARM
• Parent Unit will emit a rapid ticking sound.
• Battery Indicator slowly flashes when batteries need to be recharged.
NURSERY UNIT BATTERY ALARM
• Low Battery Indicator flashes when batteries need to be changed.
• If the batteries are not replaced, the monitor will stop working.
HOW TO CHARGE THE BATTERIES IN
THE PARENT UNIT:
Plug the AC into the Parent Unit and a working electrical outlet. Your Parent Unit can function with the batteries at 1/2 capacity but it is recommended that they are fully charged before unplugging from the AC Adaptor and power outlet for maximum use.
PARENT UNIT:
A
Right Side
B
C
D
E
Front Side
G
H
Left Side
F
A) Volume / Power
• High
• Medium
• Low
• OFF
B) Out-of-Range
Indicator
C) Bar Graph LEDs
• Sound Lights
• Alarm
• Charging Indicators
D) Power Indicator / Low
Battery Indicator
E) Speaker
F) Channel Selection
(A, B, C)
G) AC Adapter Outlet
(not shown)
H) Battery Door
(not shown)
9
10
STEP 2 - INSTALLING THE SENSOR PAD
6 5
4
3 2 1
Sensor Pad with pre-installed cord covers
Cord covers 1, 2, 3, 4:
Position on floor
Cord cover 4:
Contains double sided tape to securely install beneath crib leg
Cord cover 5:
Position vertically between mattress support and floor
Cord cover 6:
Place under the mattress
WARNING
STRANGULATION HAzARD.
Children have been STRANGLED by cords.
• Keep adapter cords out of the reach of children
(more than 1 m away).
• Because of the serious strangulation risk to infants and toddlers, parents and caregivers should never place the Nursery Unit within 1 m of a crib.
• NEVER use Sensor Pad without the cord covers.
Check cord covers before each use to ensure it is securely placed under the leg of the crib. Discontinue use of Sensor Pad if any cord covers are damaged or broken.
• NEVER use extension cords with AC adapters. ONLY use the AC adapters provided. This product is not a toy. Never allow children to play with it.
2.1 - SELECT A LOCATION FOR THE NURSERY UNIT
Select a location for the Nursery Unit that is at least 1 m away from the crib.
Sensor Pad
6
5
4
IMPORTANT
Keep at least
1 m apart
3 2 1
2.2 - SELECT THE CRIB LEG YOU WILL BE USING TO SECURE THE CORD COVERS
RECOMMENDED
6
5
Fig 1
4
3
2
1
Use the crib leg by the wall closest to the Nursery Unit (Fig 1). In cases where the Nursery Unit is across the room, use the leg closest to the Nursery Unit to position the covered wire (Fig 2). It is always preferable that the covered cord run along a wall.
OR
1
2
6
3
4
Fig 2
5
2.3 - INSTALL THE SENSOR PAD ON THE MATTRESS SUPPORT
3
4
6
5
4
3
2
1
5
1) Remove the mattress from the crib.
2) Place the Sensor Pad - printed side up
- on top of the hardboard at the center of the crib.
3) Run the connection pin, warning label and the first 5 cord covers down along the backside’s of the crib leg, between the mattress support and the inside
edge of the crib.
4) Bring the first 4 cord covers down the floor, and keep the 5 th cord cover vertically, along the backside of the crib leg, (between the mattress and the inside edge of the crib).
5) Remove any cord slack to make sure no parts of the cord are loose.
5
11
12
6
7
4
CLIC!
3
8
10
4
3
2
1
9
2
8 cm
6
1
6) Place the 6 th cord cover approximately
8 cm from the edge of the mattress support.
7) Snap together the remaining cord covers that will run along the floor.
8) Remove any cord slack to make sure no parts of the cord are loose.
9) Peel off the double-sided tape on the
4 th cord cover and place it securely under the crib leg.
10) Install the Nursery Unit on a flat, stable surface facing the crib at a distance of at least 1 m and plug the Sensor Pad cord into the Nursery Unit.
11) Check to make sure the Sensor Pad has not moved from position.
12) Place the mattress back inside the crib.
The Sensor Pad functions with any size and type of mattress except memory-foam mattresses and hollow frame mattresses.
The hardboard maintains a constant pressure on the Sensor Pad, enabling it to detect the baby’s movements even when the baby is at the edges of the crib.
WARNING
STRANGULATION HAzARD
• Remove all slack from Sensor Pad Cord.
• When lowering the mattress support as your child grows, slide the vertical
Cord Cover (5) upward so it remains approximately in the center between the mattress support and the floor. Slide the Sensor Pad Cord through the Floor
Cover to eliminate any additional slack.
• The Sensor Pad is not designed for use with adults, children or infants older than 24 months.
• Discontinue used of the Sensor Pad when child is older than 24 months.
Remove sensor pad from crib and store for future use.
• BEFORE FIRST TIME USE: To test that the unit is ready for use, refer to instruction manual on how to test that the installation has been done
STEP 3 - SETTING UP THE NURSERY UNIT
1
3
1) Remove the battery cover and insert
4 AAA Alkaline Batteries ( not included).
2) Place the Nursery Unit at a minimum
of 1 m away from the crib.
3) Connect the AC Adapter to the Nursery
Unit and plug into an electrical outlet.
NOTE:
The batteries maintain power supply in case of power outage.
2
6
5
4
Keep at least
1 m apart
3 2 1
A
B
C
NURSERY UNIT:
Front Side
D
E
F
G
H
I
Back Side
J
K
L
M
N
A) Left ‘Wing’ - Channel
Selection (A, B, C)
B) Power Indicator / Low
Battery Indicator
C) POWER ON/OFF
D) Night Light Button /
Out-of-Range Function
E) Out-of-Range Indicator
F) Movement Indicator
G) Microphone
H) Right ‘Wing’ -
Detection Mode
• Sound and Movement
• TIC OFF
• Sound Only
I) Sensor Pad Outlet
J) Night Light
K) Alarm Sound Speaker
L) Sensor Pad Sensitivity Dial
M) AC Adapter Outlet
N) Battery Door
(not shown)
13
14
STEP 4 - TURNING ON YOUR MONITOR
1
3
4
2
Power Indicator on both units will light up when monitor is turned on.
1) Slide ON Parent Unit Volume/Power button.
2) Push Nursery Unit Power ON/OFF button for 2 seconds.
3) Set both Units on the same channel
(A, B or C). Must always be on matching channels.
4) Select your detection mode .
Sound and Movement
Allows you to detect baby’s sounds and movements as well as hear a TIC sound at each movement.
Tic OFF
Allows you to detect the baby’s sounds and movements without the TIC sound.
Sound Only
Allows you to detect ONLY the baby’s sounds. Movement detection will be deactivated.
DETECTION MODE FEATURES
1
STEP 5 - TESTING AND GETTING TO KNOW YOUR MONITOR
5.1 - SENSOR PAD
TO TEST THE SENSOR PAD:
1 2
1) Move your hand lightly on the mattress.
The Nursery Unit Movement
Indicator will flash continuously.
2) Remove your hand from the mattress.
After 15 seconds you will hear a ‘TIC’ pre-alarm sound, and 5 seconds later the Movement Alarm will trigger.
3) Repeat by moving your hand lightly in all four corners of the mattress. Ensure the Nursery Unit Movement Indicator is still flashing.
MOTION ALARM
• If NO movement is detected after 15 seconds you will hear a single ‘TIC’ pre-alarm sound from the Nursery Unit.
• If after a further 5 seconds there is still NO movement detected both the Parent Unit and Nursery Unit speakers will emit a loud warning sound.
• Green light on the Nursery Unit will turn off to indicate
NO movement is being detected.
IF THE ALARM DOES NOT SOUND
• Avoid contact with crib while Sensor Pad is in operation.
• Place crib near a supporting wall.
• Adjust the Sensor Pad sensitivity level.
2
1) Movement Indicator
Light activated by your baby’s movement.
2) Sound Lights
Sound lights on the Parent
Unit are activated by the sounds of your baby. As the sounds get louder, more lights will illuminate.
TO STOP THE ALARM
Place your hand back on the mattress.
OR
Shut the Nursery
Unit OFF
15
16
TO ADJUST THE SENSOR PAD SENSITIVITY LEVEL:
Turn the Nursery Unit sensitivity dial from less sensitive (0) to very sensitive (5).
NOTE:
If you are experiencing false alarms, adjust the sensitivity level.
For better result, start by half level increases or decreases.
IMPORTANT
• The Sensor Pad is not designed for use with adults, children or infants older than 24 months.
• Once you are finished using the Sensor Pad, please remove it from the baby’s crib and store it away.
5.2 - OUT OF RANGE
Your monitor has an Out-of-Range function that advises you when your two units are not communicating. Out-of-Range situations can be caused by distance or by physical interferences.
RANGE:
Up to 250 meters (open field)
TO ACTIVATE THIS FUNCTION:
Press and hold the Nursery Unit Night
Light button for 2 seconds.
The Out-of-Range Indicator (orange) on both units will light up to display function’s activation.
TO STOP THE OUT-OF-RANGE ALARM:
Turn the Parent
Unit OFF
OR
Turn the Nursery
Unit ON
OUT-OF-RANGE ALARM
• Alarm activates when your two units are not communicating.
• The Parent Unit will emit a double beep every 8 seconds.
IMPORTANT
If the Out-of-Range function is activated and you turn the Nursery Unit OFF the Out-of-Range Alarm will sound. Turn the Nursery Unit ON again to reconnect both units. To reactivate the out-of-range function, follow steps above. If you turn the Parent
Unit OFF, the Out-of-Range function will be deactivated but the orange light will stay lit on the Nursery Unit. To reactivate this function on the Nursery Unit follow steps above.
5.3 - SOUND
TO TEST SOUND:
Ask someone to speak into the Nursery
Unit or place the unit near a radio to ensure that sound is being picked up.
IMPORTANT
To avoid feedback (whistling), keep both units at least 3 meters apart.
IF YOU HEAR NO SOUND:
• Check that both units are switched on.
• Check that both units are plugged into functioning electrical outlets.
• Check the batteries in both units
(replace or recharge them as necessary per unit).
• Bring the Parent Unit closer to the
Nursery Unit.
TO ADJUST SOUND LEVEL:
Slide Parent Unit Volume/Power button upward or downward.
5.4 - NIGHT LIGHT
Press the Night Light button on the Nursery Unit to turn it ON or OFF.
NOTE:
If you press Night Light button for more than 2 seconds Out-of-Range function automatically activates.
17
18
TROUBLESHOOTING
TAKING CARE OF YOUR RECHARGEABLE BATTERIES
• Ensure that you fully charge your batteries for 15 hours before their first use.
• To maintain maximum battery life it is recommended that you fully discharge your batteries periodically. Battery performance can be diminished by leaving the batteries constantly charging. If your parent unit is not in use, please turn it off.
• Inadequate battery power can impair the performance of your monitor. If you are not happy with the performance of your Parent Unit/Monitor please replace the rechargeable batteries (3 or 6 x NiMH Rechargeable Batteries).
• It is advisable to change the batteries every 6 months
FALSE ALARMS
• Verify the connection between Sensor Pad and Nursery Unit.
Unplug and reconnect the cord.
• Make sure there is no bedding between the mattress and the Sensor Pad.
• If the crib has a spring or slat base, place a hardboard between the crib base and the
Sensor Pad measuring at least 33 x 33 cm and 6 mm thick.
• Make sure the Sensor Pad is positioned as described under the setup requirements.
Sensitivity may need to be adjusted, refer to step 5.1.
ALARM WILL NOT SOUND
• Avoid contact with the crib when the monitor is ON.
• Place crib near a solid supporting wall to avoid Sensor Pad from detecting movement from outside the crib.
• Turn OFF crib mobile, fans, loud music or anything else that may cause vibration.
• You may need to decrease the sensitivity, refer to step 5.1.
NO SOUND IS BEING TRANSMITTED
• Ensure that both units are switched ON.
• Check that the sound has not been turned down on the Parent Unit. Increase the volume level on the Parent Unit, refer to step 5.3.
• If there is no power to any unit check/replace the batteries, recharge the Parent Unit & check the AC Adaptors are working. Change electrical outlets if required.
• Bring the Parent Unit and Nursery Unit closer together.
POWER INDICATOR (GREEN LIGHT) DOES NOT LIGHT UP
• Check/replace batteries or recharge the Parent Unit.
• Check connections or change to another electrical outlet.
• Ensure both units are on the same channel, either A, B or C.
WEAK RECEPTION
• Bring units closer together.
• Change the position of one or both units.
• Place units on a flat surface away from baby’s reach.
• Replace the batteries or recharge the Parent Unit.
STATIC, DISTORTION, INTERFERENCES
(FROM OTHER MONITORS, WIRELESS PHONES, WALKIE-TALKIES, ETC…)
• Rotate the Parent Unit or move it away from source of interference.
• Check/replace batteries or recharge Parent Unit.
FEEDBACK (LOUD NOISES EMITTED FROM THE PARENT UNIT)
• Move the units farther apart (at least 3 meters).
• Decrease volume on the Parent Unit.
LIMITED WARRANTY
Angelcare ® warrants to the original owner of this product that Angelcare ® rechargeable, movement and sound monitor (model AC601) is free from any material and workmanship defects, for a period of one (1) year (rechargeable batteries not included) from the date of the original purchase. If this monitoring system fails to function properly when used as directed under normal conditions within the one year period, Angelcare ® will either repair or replace the product, at our discretion, free of charge. Please contact your distributor.
The product must be accompanied by a proof of purchase, either a bill of sale or other proof that the monitoring system is within the warranty period. Angelcare ® will bear the cost of repairing or replacing the product and shipping it back to you.
This warranty does not apply to a product which has been damaged as a result of improper maintenance, an accident, improper voltage supply or any other form of misuse. The warranty is also void if the owner repairs or modifies the product in any way.
Angelcare ® is not liable for any incidental or consequential damages with regard to this product. The warranty also excludes any liability other than what is stated above.
No other warranty is given.
This warranty does not cover products and accessories which are not Angelcare-branded, or any problems that result from usage that is not in accordance with product instructions, failure to follow the product instructions, or problems caused by using accessories, parts or components not supplied by Angelcare.
LEGAL RIGHTS VARY FROM COUNTRY TO COUNTRY. SOME COUNTRIES DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO
THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
WE ARE NOT IN ANY WAY RESPONSIBLE FOR ANY OUTCOME RESULTING FROM
THE USE OF THIS PRODUCT.
IMPORTANT!
This Angelcare ® monitor is a personal care product. Please do not return this product to the store. If you have questions or need help, please call your distributor before returning this product.
19
TECHNICAL SPECIFICATIONS
Range:
Open field : up to 200 m
Number of Channels:
USA/Canada: 3 channels.
Europe: 3 Channels.
Power Supply:
4 AAA alkaline batteries (not included) or 100-240V AC/7.5V DC Adapter for
Nursery Unit.
3 AAA rechargeable batteries
(included) and 100-240V AC/7.5V DC adapter for the Parent Unit.
Caution: To reduce the risk of electric shock, do not expose this product to rain or moisture.
Danger of explosion if batteries are incorrectly replaced. The included batteries are 3 AAA NIMH rechargeble batteries manufactured by GPI INTERNATIONAL
LIMITED (GN60AAAHC, 1.2V 600MAH).
They may only be replaced by 3 AAA
NIMH rechargable batteries.
Batteries:
• DO NOT mix old and new batteries.
• DO NOT mix alkaline, standard
(carbon-zinc) or rechargable
(NI-CD, NIMH, etc) batteries.
Transmission:
Movement signal and sound transmission from Nursery Unit to Parent Unit is made on the 864MHz frequency. Transmission from the Nursery Unit to the Parent Unit is made on the 864 MHz frequency in Europe/
Asia/Africa and on the 927 MHz frequency for North America/Ecuador/Oceania.
Hereby, Angelcare Monitors Inc, declares this baby monitor is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
The EU declaration of conformity can be obtained through your local distributor.
Please refer to address in the manual.
20
PROTECT THE ENVIRONMENT
This electronic equipment contains reusable material and must not be disposed with domestic waste. Please take it to a collecting point for electric and electronic equipment (ask your local authorities for details).
ErP COMPLIANCE
NORTH AMERICA
Use only Angelcare ® brand power supply - model number: T07505U002
UK- MALTA- CYPRUS – SINGAPORE - HK- UAE
Use only Angelcare ® Brand power supply – model number: T07505B001
EUROPEAN UNION – SOUTH AFRICA – BRAZIL – RUSSIA
Use only Angelcare ® Brand power supply – model number: T07505V001
GERMANY
Use only Angelcare ® Brand power supply – model number: T07505F002
AUSTRALIA
Use only Angelcare ® Brand power supply – model number: T07505S002 (MEPS)
21
22 23
This Angelcare Baby Monitor is a Personal Care Product. Please DO NOT return
this to the store, but contact us initially for advice and assistance:
Angelcare Helpline on 0845 009 1789
Website: www.angelcare.co.uk
Email: [email protected]
NOTE: Helpline is open Monday to Friday, 10am to 4pm, excluding bank holidays.
advertisement
Key Features
- Movement sensor
- Sound transmission
- Adjustable sensitivity
- Night light
- Out-of-range function
- Rechargeable batteries
- AC adapter
- Cord covers
- Alarm
- Channels
Related manuals
Frequently Answers and Questions
What should be done if the monitor alarms despite no movement being detected?
How should the rechargeable batteries be inserted into the Parent Unit?
What safety measures should be taken with the Sensor Pad cord?
How does the sound transmission work?
What should be done if the Parent Unit does not charge?
Where should the Nursery Unit be placed?
advertisement
Table of contents
- - WARNING
- 1 AC601 SETUP REQUIREMENTS
- 2 STEP 1 - Charging the Parent Unit (15 hours)
- 4 STEP 2 - Installing the sensor pad
- 7 STEP 3 - Setting up the nursery unit
- 8 STEP 4 - Turning on your monitor
- 9 STEP 5 - Testing and getting to know your monitor
- 12 Troubleshooting
- 13 Limited warranty
- 11 Technical specifications