DATALOGIC DX6400 MASTER/SLAVE, ETHERNET bar code reader QUICK REFERENCE GUIDE
Werbung
Werbung
DX6400
QUICK REFERENCE GUIDE
CONTENTS
DX6400-100-010 MASTER/SLAVE MODEL ...........................................................................................................1
DX6400-100-012 ETHERNET MODEL ....................................................................................................................9
COMMON FEATURES ..........................................................................................................................................15
NOTE
For further details on product installation, see the complete Reference Manual available on the configuration CD-ROM included with this product.
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its website. Log on to
www.automation.datalogic.com and click on the links indicated for further information including:
• PRODUCTS
Search through the links to arrive at your product page where you can download specific Manuals and
Software & Utilities including:
- Genius™ a utility program, which allows device configuration using a PC. It provides RS232 interface configuration.
• SERVICES & SUPPORT
- Datalogic Services - Warranty Extensions and Maintenance Agreements
- Authorised Repair Centres
• CONTACT US
E-mail form and listing of Datalogic Subsidiaries
DX6400-100-010 MASTER/SLAVE MODEL
1
DX6400 MASTER/SLAVE MODEL
1
Figure A
Laser Beam Output Window
5 1
4 3 2
Figure B
1
2
Programming Keypad
TX Data LED (Green)
3 Phase On LED (Yellow)
4
5
Power On LED (Red)
LCD Display
Available Models:
DX6400 - 100 - 0XX
3
1
2
Figure C
1
2
3
Main/Aux. Interface 25-pin D-sub Male Connector
Lonworks 9-pin Male Connector
Lonworks 9-pin Female Connector
Decoder Model
10 = Master/Slave
12 = Ethernet
Technical Features:
ELECTRICAL FEATURES
Supply voltage
Power consumption
Communication Interfaces
Inputs
External Trigger 1,
3 auxiliary digital inputs
Outputs
3 software programmable digital outputs
15 to 30 Vdc
18 W typical
24 W Max. (including startup current)
Main (isolated)
RS232
RS485 full-duplex
Baud Rate
1200 to 115200
1200 to 115200
1200 to 115200 RS485 half-duplex
20 mA Current Loop
(INT-30 with C-BOX 100 only)
19200
Auxiliary
RS232
Other
1200 to 115200
(optocoupled NPN or PNP)
(optocoupled)
1
DX6400 MASTER/SLAVE MODEL
OPTICAL FEATURES
Light receiver
Wavelength
Safety class
Light source
Laser control
READING FEATURES
Scan rate
Maximum resolution
Max. reading distance
Max. reading width
Max. depth of field
USER INTERFACE
LCD Display
Avalanche photodiode
630 to 680 nm
Class 2 - EN60825-1; Class II - CDRH
Up to 2 semiconductor laser diodes
Security system to turn laser off in case of motor slow down up to 1500 scans/s (750 per leg)
(see reading diagram)
2 lines by 16 characters LCD
LED indicators Power ON (red)
Phase ON (yellow)
TX data (green)
SOFTWARE FEATURES
Readable Codes Interleaved 2/5
Code 39 Standard
Codabar
EAN128
Code 93 (standard and full ASCII)
EAN/UPC EAN/UPC (including Add-on 2 and Add-on 5)
Code selection
Headers and Terminators
Up to 10 codes during one reading phase
Transmitted messages can be personalized using up to 128-byte headers and 128-byte terminators
Operating modes
Configuration modes
Parameter storage
On Line
Automatic
Test
PackTrack
Genius™ utility program
Non-volatile internal FLASH
ENVIRONMENTAL FEATURES
Operating temperature
Storage temperature
Humidity
Ambient light immunity
Vibration resistance
IEC 68-2-6 test FC
2 hours on each axis
Shock resistance
IEC 68-2-27 test EA
3 shocks on each axis
Protection class
PHYSICAL FEATURES
Mechanical dimensions
Weight
0° to +40 °C (+32° to +104 °F)
-20° to +70 °C (-4° to +158 °F)
90% non condensing
10000 lux
14 mm @ 2 to 10 Hz
1.5 mm @ 13 to 55 Hz
2 g @ 70 to 200 Hz
30 g; 11 ms
IP64
225.9 x 149.8 x 116.8 mm (8.89 x 5.90 x 4.60 in)
2.1 kg. (4.62 lbs)
2
DX6400 MASTER/SLAVE MODEL
Accessories:
Name Description
CAB-6305
CAB-6310
CAB-6502
CAB-6505
C-BOX 100
C-BOX 300
C-BOX 310
C-BOX 400
C-BOX 410
FBK-6000
INT-30
PH-1
MEP-543
PG6002
BTK-6000
CAB-6001
CAB-6002
CAB-6005
CAB-6010
CAB-6011
CAB-6012
CAB-6015
CAB-6101
CAB-6102
CAB-6105
CAB-6112
CAB-6115
PG6001
PG6000
PWR-120
PWR-240
PWR-480
OEK-2
Bus terminator kit (5 pcs)
25-pin scanner to C-BOX100 cable 1 m
25-pin scanner to C-BOX100 cable 2 m
25-pin scanner to C-BOX100 cable 5 m
25-pin scanner to C-BOX100 cable 10 m
26-pin scanner to C-BOX100 cable 1 m (Ethernet version)
26-pin scanner to C-BOX100 cable 2 m (Ethernet version)
26-pin scanner to C-BOX100 cable 5 m (Ethernet version)
9-pin scanner/scanner connection cable 1 m
9-pin scanner/scanner connection cable 2 m
9-pin scanner/scanner connection cable 5 m
9-pin scanner to scanner no power cable 2 m
9-pin scanner to scanner no power cable 5 m
25-pin power cable Fam 6k 5 m
25-pin power cable Fam 6k 10 m
Fam 6K-8K cross cable 2.5 m
Fam 6K-8K cross cable 5 m
Passive connection box
Profibus-DP connection box
Profibus-DP connection box with display
Devicenet connection box
Devicenet connection box with display
Fast bracket kit (2 pcs)
20 m.A. C.L. interface board for C-BOX 100
Photocell kit – PNP
Photocell kit - NPN
Single unit power supply (US)
Single unit power supply (UK)
Single unit power supply (EU)
J-box power unit 110/230 VAC 24 V 120 W
J-box power unit 110/230 VAC 24 V 240 W
J-box power unit 110/230 VAC 24 V 480 W
Optical encoder (10 m cable + spring)
OEK-1 Optical encoder kit + 10 m 93ACC1600
Electrical Connections:
The DX6400 reader provides a 25-pin male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals.
Two 9-pin connectors provide access to the scanner’s local Lonworks network used for both input and output connections to build a multi-sided or omni-station system.
93ACC1710
93A051190
93A051200
93A051210
93A051271
93A051221
93A051222
93A051223
93A051220
93A051230
93A051240
93A051224
93A051225
93ACC1768
93ACC1752
93A051288
93A051289
93ACC1510
93A301000
93A301030
93A301010
93A301040
93ACC1721
93A151022
93ACC1791
93ACC1728
93ACC1718
93ACC1719
93ACC1720
93ACC1530
93ACC1070
93ACC1080
93ACC1770
3
DX6400 MASTER/SLAVE MODEL
The details of the connector pins are indicated in the following table:
Pin Name
1 CHASSIS
20 RXAUX
21 TXAUX
8 OUT 1+
22 OUT 1-
25-pin D-Sub Connector Pinout
Function
Chassis - internally connected to GND
Cable shield connected to chassis
Receive data of auxiliary RS232 (referred to GND)
Transmit data of auxiliary RS232 (referred to GND)
Configurable digital output 1 – positive pin
Configurable digital output 1 – negative pin
12 OUT 2- Configurable digital output 2 – negative pin
1 13
18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS
19 EXT_TRIG/PS B External trigger (polarity insensitive) for PS
6 IN2/ENC A
10 IN2/ENC B
Input signal 2 (polarity insensitive) for Encoder
Input signal 2 (polarity insensitive) for Encoder
14 IN3A
15 IN4A
24 IN_REF
9, 13 VS
23, 25 GND
Input signal 3 (polarity insensitive)
Input signal 4 (polarity insensitive)
Common reference of IN3 and IN4 (polarity insensitive)
Supply voltage – positive pin
Supply voltage – negative pin
14 25
25-pin male D-sub Connector
Pin RS232
2 TX
3 RX
4 RTS
5 CTS
7 GND_ISO
RS485 Full-Duplex RS485 Half-Duplex
20 mA C.L.
(INT-30 with C-BOX 100 only)
TX485+ RTX485+
TX485- RTX485-
GND_ISO GND_ISO
* Do not leave floating, see Reference Manual for connection details.
9-pin Lonworks Connector Pinout
Pin Name Function
1 CHASSIS
9
2
VS
GND
6 VS_I/O
3 Ref_I/O
Cable shield internally connected by capacitor to chassis
Supply voltage – positive pin
Supply voltage – negative pin
Supply voltage of I/O circuit
Reference voltage of I/O circuit
5 1 1 5
9
Female
6 6
Male
9
9-pin Local Lonworks Connectors
5 SYS_I/O
7 LON A
8 LON B
Lonworks line (polarity insensitive)
Lonworks line (polarity insensitive)
Network Termination:
When building a local Lonworks system the network must be properly terminated by positioning a BTK-6000 terminator on the DX6400 master reader (BTK-6000 female side) and on the last slave reader (BTK-6000 male side). to Master to Slave
9-pin female 9-pin male
BTK-6000 Network Terminator
4
Connectivity:
CAB-600X
Point-to-Point Layout
C-BOX 100
DX6400
DX6400 MASTER/SLAVE MODEL
Local Host
P.S.*
PG6000
* P.S. (Presence Sensor) connected to External Trigger/PS input.
Pass Through Layout
P.S.* P.S.*
DX6400
DS4600A
P.S.*
CAB-600X
C-BOX 100
MAIN
AUX
2
1
Local Host
C-BOX 100
1 2
PWR-120
1 Main Serial Interface 2 Auxiliary Serial Interface
* P.S. (Presence Sensor) connected to External Trigger/PS input.
C-BOX 100
DS4600A
1
Gryphon
5
P.S.* P.S.*
Multiplexer Layout
P.S.*
DX6400 MASTER/SLAVE MODEL
DX6X00
CAB-600X
C-BOX 100
DS4600A
C-BOX 100
DS4600A
PWR-120
C-BOX 100
MX4000
#31 #1 #0
Local Host
1
1 RS485 HD Main Interface
* P.S. (Presence Sensor) connected to External Trigger/PS input.
RS232 Master/Slave Layout
DX6400
Master
CAB-600X
1
DS4600A
Slave 1
P.S.*
C-BOX 100
AUX
MAIN
1
2
C-BOX 100
2
DS4600A
Slave 2
C-BOX 100
PWR-120
1 Main Serial Interface 2
1
Auxiliary Serial Interface
* P.S. (Presence Sensor) connected to External Trigger/PS input.
6
Local Host
CAB-610X
DX6400 MASTER/SLAVE MODEL
Local Lonworks Network
CAB-60XX
BTK-6000 C-BOX 100**
Master
Slave 1
P.S.*
CAB-63XX
BTK-6000
PWR-120
Small Synchronized Network with 2 readers
* P.S. (Presence Sensor) connected to External Trigger/PS input.
** C-BOX 100 modified to accept scanner power.
*** Encoder connected to IN2/ENC input.
Local Lonworks Network
Slave 2 Slave1 Master
Encoder***
Local Host
CAB-610X
CAB-610X
CAB-610X
CAB-610X
CAB-610X
BTK-6000
CAB-60XX
C-BOX 100**
Host
PS*
Encoder***
CAB-63XX
BTK-6000
PWR-240
Slave 5
Slave 4 Slave 3
CAB-63XX
Small Synchronized Network with more than 2 Readers and Single Power Unit
* P.S. (Presence Sensor) connected to External Trigger/PS input.
** C-BOX 100 modified to accept scanner power. connected to IN2/ENC input.
7
Large Synchronized Network
DX6400 MASTER/SLAVE MODEL
*
**
P.S. (Presence Sensor) connected to External Trigger/PS input.
Encoder connected to ENC input.
Large Synchronized Network with DX6400 and DS6XXX Scanners
*
**
8
DX6400-100-012 ETHERNET MODEL
1
DX6400 ETHERNET MODEL
5
1
Figure A
Laser Beam Output Window
1
3
2
4 3 2
Figure B
1
2
Programming Keypad
TX Data LED (Green)
3 Phase On LED (Yellow)
4 Power On LED (R
5 LCD Display
Available Models:
DX6400 - 100 - 0XX
1
Figure C
1
2
3
RJ45 Modular Connector for Ethernet Interface
Lonworks 9-pin Female Connector
Main/Aux. Interface 26-pin D-Sub Male Connector
Decoder Model
10 = Master/Slave
12 = Ethernet
Technical Features:
ELECTRICAL FEATURES
Supply voltage
Power consumption
Communication Interfaces
15 to 30 Vdc
18 W typical
24 W Max. (including startup current)
Main (isolated) Baud Rate
RS232
RS485 full-duplex
RS485 half-duplex
20 mA Current Loop
(INT-30 with C-BOX 100 only)
1200 to 115200
1200 to 115200
1200 to 115200
19200
Auxiliary
RS232
Other
1200 to 115200
Model–Dependent Communication
Interfaces
Inputs
External Trigger 1,
3 auxiliary digital inputs
Outputs
3 software programmable digital outputs
Ethernet 10 or 100 Mb/s
(optocoupled NPN or PNP)
(optocoupled)
9
DX6400 ETHERNET MODEL
OPTICAL FEATURES
Light receiver
Wavelength
Safety class
Light source
Laser control
READING FEATURES
Scan rate
Maximum resolution
Max. reading distance
Max. reading width
Max. depth of field
USER INTERFACE
LCD Display
Avalanche photodiode
630 to 680 nm
Class 2 - EN60825-1; Class II - CDRH
Up to 2 semiconductor laser diodes
Security system to turn laser off in case of motor slow down up to 1500 scans/s (750 per leg)
(see reading diagram)
2 lines by 16 characters LCD
LED indicators Power ON (red)
Phase ON (yellow)
TX data (green)
SOFTWARE FEATURES
Readable Codes Interleaved 2/5
Code 39 Standard
Codabar
EAN128
Code 93 (standard and full ASCII)
EAN/UPC EAN/UPC (including Add-on 2 and Add-on 5)
Code selection
Headers and Terminators
Up to 10 codes during one reading phase
Transmitted messages can be personalized using up to 128-byte headers and 128-byte terminators
Operating modes
Configuration modes
Parameter storage
On Line
Automatic
Test
PackTrack
Genius™ utility program
Non-volatile internal FLASH
ENVIRONMENTAL FEATURES
Operating temperature
Storage temperature
Humidity
Ambient light immunity
Vibration resistance
IEC 68-2-6 test FC
2 hours on each axis
Shock resistance
IEC 68-2-27 test EA
3 shocks on each axis
Protection class
PHYSICAL FEATURES
Mechanical dimensions
Weight
0° to +40 °C (+32° to +104 °F)
-20° to +70 °C (-4° to +158 °F)
90% non condensing
10000 lux
14 mm @ 2 to 10 Hz
1.5 mm @ 13 to 55 Hz
2 g @ 70 to 200 Hz
30 g; 11 ms
IP50
225.9 x 149.8 x 116.8 mm (8.89 x 5.90 x 4.60 in)
2.1 kg. (4.62 lbs)
10
DX6400 ETHERNET MODEL
Accessories:
Name Description
CAB-6305
CAB-6310
CAB-6502
CAB-6505
C-BOX 100
C-BOX 300
C-BOX 310
C-BOX 400
C-BOX 410
FBK-6000
INT-30
PH-1
MEP-543
PG6002
BTK-6000
CAB-6001
CAB-6002
CAB-6005
CAB-6010
CAB-6011
CAB-6012
CAB-6015
CAB-6101
CAB-6102
CAB-6105
CAB-6112
CAB-6115
PG6001
PG6000
PWR-120
PWR-240
PWR-480
OEK-2
Bus terminator kit (5 pcs)
25-pin scanner to C-BOX100 cable 1 m
25-pin scanner to C-BOX100 cable 2 m
25-pin scanner to C-BOX100 cable 5 m
25-pin scanner to C-BOX100 cable 10 m
26-pin scanner to C-BOX100 cable 1 m (Ethernet version)
26-pin scanner to C-BOX100 cable 2 m (Ethernet version)
26-pin scanner to C-BOX100 cable 5 m (Ethernet version)
9-pin scanner/scanner connection cable 1 m
9-pin scanner/scanner connection cable 2 m
9-pin scanner/scanner connection cable 5 m
9-pin scanner to scanner no power cable 2 m
9-pin scanner to scanner no power cable 5 m
25-pin power cable Fam 6k 5 m
25-pin power cable Fam 6k 10 m
Fam 6K-8K cross cable 2.5 m
Fam 6K-8K cross cable 5 m
Passive connection box
Profibus-DP connection box
Profibus-DP connection box with display
Devicenet connection box
Devicenet connection box with display
Fast bracket kit (2 pcs)
20 m.A. C.L. interface board for C-BOX 100
Photocell kit – PNP
Photocell kit - NPN
Single unit power supply (US)
Single unit power supply (UK)
Single unit power supply (EU)
J-box power unit 110/230 VAC 24 V 120 W
J-box power unit 110/230 VAC 24 V 240 W
J-box power unit 110/230 VAC 24 V 480 W
Optical encoder (10 m cable + spring)
OEK-1 Optical encoder kit + 10 m 93ACC1600
Electrical Connections:
The DX6400 Ethernet reader provides a 26-pin male D-sub connector for connection to power supply and input/output signals.
An Ethernet connector is used for connection to the remote Host (for ex. Remote PC connected via Internet), while a local Lonworks 9-pin female connector connects the Ethernet master to the first slave reader of the system.
The details of the connector pins are indicated in the following table:
93ACC1710
93A051190
93A051200
93A051210
93A051271
93A051221
93A051222
93A051223
93A051220
93A051230
93A051240
93A051224
93A051225
93ACC1768
93ACC1752
93A051288
93A051289
93ACC1510
93A301000
93A301030
93A301010
93A301040
93ACC1721
93A151022
93ACC1791
93ACC1728
93ACC1718
93ACC1719
93ACC1720
93ACC1530
93ACC1070
93ACC1080
93ACC1770
11
DX6400 ETHERNET MODEL
Pin Name
1 CHASSIS
20
21
8
22
RXAUX
TXAUX
OUT 1+
OUT 1-
26-pin D-Sub Connector Pinout
Function
Chassis - internally connected to GND
Cable shield connected to chassis
Receive data of auxiliary RS232 (referred to GND)
Transmit data of auxiliary RS232 (referred to GND)
Configurable digital output 1 – positive pin
Configurable digital output 1 – negative pin
12 OUT 2- Configurable digital output 2 – negative pin
1
10
19 26
18
9
18
19
6
10
EXT_TRIG/PS A External trigger (polarity insensitive) for PS
EXT_TRIG/PS B External trigger (polarity insensitive) for PS
IN2/ENC A
IN2/ENC B
Input signal 2 (polarity insensitive) for Encoder
Input signal 2 (polarity insensitive) for Encoder
14
15
IN3A
IN4A
24 IN_REF
9, 13 VS
23, 25, 26 GND
Input signal 3 (polarity insensitive)
Input signal 4 (polarity insensitive)
Common reference of IN3 and IN4 (polarity insensitive)
Supply voltage – positive pin
Supply voltage – negative pin
26-pin male D-sub Connector
Pin RS232 RS485 Full-Duplex RS485 Half-Duplex
20 mA C.L.
(INT-30 with C-BOX 100 only)
2 TX TX485+ RTX485+
3 RX *
4 RTS TX485- RTX485-
5 CTS *
7 GND_ISO GND_ISO GND_ISO
* Do not leave floating, see Reference Manual for connection details.
9-pin Lonworks Connector Pinout
Pin Name
1 CHASSIS
9
2
6
VS
GND
VS_I/O
3 Ref_I/O
5 SYS_I/O
7
8
LON A
LON B
Function
Cable shield internally connected by capacitor to chassis
Supply voltage – positive pin
Supply voltage – negative pin
Supply voltage of I/O circuit
Reference voltage of I/O circuit
Lonworks line (polarity insensitive)
Lonworks line (polarity insensitive)
5 1
9 6
9-pin female Local Lonworks Connector
DS6400 HUB / SWITCH
RJ45 Modular Connector
TX+
TX-
1
2
1
2
1 8
3 3 RX+ n. c. n. c.
4
5
4
5
RX- n. c.
6
7
6
7
RJ45 Modular Connector n. c. 8 8 n. c. = not connected
12
Connectivity:
C-BOX 100
CAB-601X
Point-to-Point Layout
Fieldbus
Network
DX6400
DX6400 ETHERNET MODEL
Remote Host
P.S.*
PG6000
* P.S. (Presence Sensor) connected to External Trigger/PS input.
Pass Through Layout
Remote Host
P.S.* P.S.* P.S.*
Fieldbus
Network
DX6500
CAB-601X C-BOX 100
AUX
PWR-120
2
C-BOX 100
DS4600A
1
2
1 Main Serial Interface 2 Auxiliary Serial Interface
* P.S. (Presence Sensor) connected to External Trigger/PS input.
C-BOX 100
1
DS4600A
Gryphon
13
Slave 2*** Slave1***
Local Lonworks Network
Fieldbus
Network
Master
DX6400 ETHERNET MODEL
Remote Host
C-BOX 100**
CAB-610X CAB-610X CAB-60XX
CAB-610X
BTK-6000
PS*
Encoder****
CAB-610X CAB-610X
CAB-63XX
PWR-240
Slave 5*** Slave 4*** Slave 3***
CAB-63XX
Fieldbus Small Synchronized Network
*
**
P.S. (Presence Sensor) connected to External Trigger/PS input.
C-BOX 100 modified to accept scanner power.
*** The Slave scanners are Master/Slave models, which allow Lonworks network propagation.
**** Encoder connected to IN2/ENC input.
14
COMMON FEATURES
COMMON FEATURES
C-BOX 100 Pinout for DX6400:
The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DX6400 reader is connected in a network by means of the C-BOX 100:
C-BOX 100 Terminal Block Connectors
1, 3, 5
2, 4, 6
7, 8
20, 40
27
28
29
30
31, 33
32, 34
36
Power
VS
GND
EARTH GROUND
Reserved
Inputs
EXT TRIG/PS A (polarity insensitive) for PS
EXT TRIG/PS B (polarity insensitive) for PS
IN 2/ENC A (polarity insensitive) for Encoder
IN 2/ENC B (polarity insensitive) for Encoder
IN 3A (polarity insensitive)
IN 4A (polarity insensitive)
IN 3B/IN 4B Reference (polarity insensitive)
Outputs
25
26
OUT 3A (polarity insensitive)
OUT 3B (polarity insensitive)
Auxiliary Interface
38, 39 GND
Main Interface
RS232
RS485
Full-Duplex
RS485
Half-Duplex
11, 15
12, 16
TX232
RTS232
TX485+
TX485-
17 RX232 *
RTX485+
RTX485-
18 CTS232
10, 14, 19 SGND Main Isolated
*
SGND Main Isolated SGND Main Isolated
9, 13 RS485 Cable Shield RS485 Cable Shield
* Do not leave floating, see Reference Manual for connection details.
20 mA C.L.
(with INT-30 only) see INT-30 instructions
15
COMMON FEATURES
Mechanical Installation:
The DX6400 reader can be positioned and installed in the best way possible as a result of the Step-A-Head
TM feature. Thanks to the separation between Head and Base, you can modify the orientation of the decoder base, and therefore display-keypad and connector panels, while keeping the optic head in the correct reading position.
The reading head and the decoder base can be rotated independently from each other allowing the installation even in the most critical locations.
To rotate the head follow the given procedure:
Head Screws
1. detach the head from the base by unscrewing the four fixing screws;
2. rotate the head in the desired position;
3. loosen but don't remove the two screws on top of the head;
4. affix the head onto the base carefully aligning the four fixing screws and progressively tightening them about half-way;
5. completely tighten the two screws on top of the head;
Fixing
Screw (4)
6. completely tighten the four fixing screws. Step- A-Head™ Feature
The following diagrams give the overall dimensions of the reader standard model, oscillating mirror model and mounting bracket. They may be used for their installation:
16
115.9
[4.56]
125.3
[4.93]
225.9
[8.89]
85
[3.35]
16.5
[0.65]
18 0.7
82 3.2
20 0.7
Ø4
.1
Ø0
N°
2
.16
N°
2
10
0.4
42
1.65
22
0.86
=
=
50
1.96
72
2.83
100
3.93
=
=
8.5 N°
2 SLO
TS
LOTS
0.33
N°2 S
Ø8
.5
Ø0
.33
4.5
N°
4 S
LO
TS
OT
S
0.1
8 N
°4
SL
35 1.
50 1.9
82 3.
4.9
6
12
6
106°
73.2
2.88
mm inch
4
0.15
DX6400 Overall Dimensions ST-237 Mounting Bracket Overall Dimensions
COMMON FEATURES
Mount the scanner using the ST-237 mounting bracket which assures an angle of 16°, as indicated in the figure below, in order to obtain an angle of 90° between the two scan lines. This guarantees an omni directional reading of the barcode, if the code label satisfies the ACR™ 4 conditions (see Scanner Reference Manual for details).
DX6400 Mounting Position
WARNING
When installing several scanners, take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners. This condition could occur more frequently for side mounted applications. If these precautions are not followed, it may occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position of one of the two scanners involved.
FLASH™ Dynamic Focus:
The DX6400 has an innovative linear motor designed to control the focus position of the scanner via software.
This dynamic system, called FLASH™, is able to move the focus position rail to rail, from the minimum position to the maximum position.
The FLASH™ functionalities (i.e. the driving modes of the linear motor) are programmed via the Genius™ software tool and can operate in the following modes:
- Fixed mode: the focus is set to the desired position via software (expressed in cm);
- Continuous mode: the focus position is continuously running from a minimum position to a maximum position with a defined frequency;
- Triggered mode: the focus position can be set depending on the received external input (photocell, barrier, serial message, etc.);
- D-Flash™ mode: the focus position can be set depending on the measured distance between the scanner and the scanned object. This is the most innovative and flexible function that makes different software implementations possible. The D-Flash™ development has been based on the minimum distance detected.
Thus, it can apply to the widest variety of applications. Further developments of D-Flash™ will be provided according to the specific application needs.
17
COMMON FEATURES
Reading Conditions:
• ANSI Grade B minimum
• 600 scans/sec per leg
The following tables describe the requirements for standard applications.
2/5 Inteleaved
Code Resolution (mm)
Minimum Code Height for Omnidirectional Reading (mm)
0.5 1 1.5 2 2.5 3
0.38
0.50
0.60
1.00
14 16 18 20 22 24
18 19 21 23 25 27
21 22 24 26 28 30
34 35 36 37 39 41
Table 1
Code 39
Code Resolution (mm)
Minimum Code Height for Omnidirectional Reading (mm)
0.5 1 1.5 2 2.5 3
0.38
0.50
0.60
1.00
12 13 15 17 19 21
15 16 17 19 21 24
18 19 20 21 23 26
28 29 30 31 32 34
Table 2
Code 128 – Ean 128
Code Resolution (mm)
Minimum Code Height for Omnidirectional Reading (mm)
0.5 1 1.5 2 2.5 3
0.38
0.50
0.60
1.00
10 12 14 16 18 20
12 13 16 18 20 22
14 15 17 19 21 24
22 23 24 26 28 30
Table 3
Codabar
Code Resolution (mm)
Minimum Code Height for Omnidirectional Reading (mm)
0.5 1 1.5 2 2.5 3
0.38
0.50
0.60
1.00
16 18 20 22 24 26
20 22 24 26 28 30
23 25 27 29 31 34
36 38 40 42 44 47
Table 4
EAN 8-13, UPC-A
Code Resolution (mm)
Minimum Code Height for Omnidirectional Reading (mm)
0.5 1 1.5 2 2.5 3
0.38
0.50
0.60
1.00
11 12 13 15 17 19
13 14 15 16 18 20
15 16 17 18 19 22
24 25 26 27 28 29
Table 5
18
COMMON FEATURES
Reading Diagrams:
DX6400-100-0XX – Resolution: 0.38 mm/15 mils
0 -20 -30
-40
0 -40 -50 -60 -70 -80
-40 -50 -60 -70
-90 -100 -110 -120 -130 -140 -150 -160 -170 -180 (cm) z
-10
-30
-20
-10
0 0
10 x 20
10
30
40
(in) (cm)
Note: x = 0 and z = 0 correspond to the edge of the DX6400 scanner as shown in the figure above.
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
DX6400-100-0XX – Resolution: 0.50 mm/20 mils
0 -20 -30
-40
0 -40 -50 -60 -70 -80
-40 -50 -60 -70 (in)
-90 -100 -110 -120 -130 -140 -150 -160 -170 -180 (cm) z x
-10
-30
-20
-10
0 0
10
20
10
30
40
(in) (cm)
Note: x = 0 and z = 0 correspond to the edge of the DX6400 scanner as shown in the figure above.
CONDITIONS
Code = Interleaved 2/5 or Code 39
PCS = 0.90
19
COMMON FEATURES
User Interface:
1 5
RS232 PC-side connections
1 13
6 9
9-pin male connector
14 25
25-pin male connector
Pin Name Name
2 RX RX
3 TX TX
5 GND GND
7 RTS RTS
8 CTS CTS
How To Build A Simple Interface Test Cable:
The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC
RS232 COM port connections.
25-pin D-sub female 9-pin D-sub female
DX6400
21 TXAUX
20 RXAUX
23 GND
13 VS
25 GND
9 VS
18 EXT TRIG A
19 EXT TRIG B
2
3
5
Power Supply
VS (15 – 30 VDC)
Power GND
RX
TX
GND
PC
Trigger
Compliance:
Laser Safety
1
1
2
1
Figure A
Laser Safety Label
2 Identification Label
1
Figure B
Warning and Device Class Label
20
COMMON FEATURES
The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations.
Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light.
There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed.
The laser beam can be switched off through a software command (see also the Genius™ Help On-Line).
AVOID EXPOSURE – LASER LIGHT
IS EMITTED FROM THIS APERTURE
Laser Safety Label
CAUTION-CLASS 3B
LASER LIGHT
WHEN OPEN
AVOID EXPOSURE
TO BEAM
LASER LIGHT – DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1 mW
EMITTED WAVE LENGTH 630 ~ 680 nm
EN60825-1:2001
DATALOGIC S.p.A. Via Candini, 2
40012 LIPPO DI CALDERARA DI RENO (BO) ITALY
MANUFACTURED VOLT Amp.
JANUARY 2005 15-30 DC 1.5-0.7
MODEL No. N2468
SERIAL No.
This product conforms to the applicable requirements of 21CFR 1040 at the date of manufacture.
Warning and Device Class Label Device Identification Label
The laser diode used in this device is classified as a Class 3B laser product according to EN 60825-1 regulations and as a Class IIIb laser product according to CDRH regulations. Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (35 mW at 630 ~ 680 nm).
Power Supply
- This product is intended to be installed by Qualified Personnel only.
- All DX6400 Models:
This device is intended to be supplied by a UL Listed Power Unit marked “Class 2” or LPS power source which supplies power directly to the scanner via the 25/26-pin connector.
CE Compliance
Warning:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Patents
This product is covered by one or more of the following patents:
U.S. patents: 5,483,051; Re. 36,251; 6,049,406; 5,992,740; 6,347,740B1; 6,629,639B2; 6,394,352B1;
6,742,710B2; 7,161,685B1; 6,688,524B1; 6,443,360 B1; 7,195,162B2.
European patents: 652,530B1; 786,734B1; 789,315B1; 851,376B1; 1,363,228B1; 959,426B9; 1,300,798B1.
Additional patents pending.
21
DECLARATION OF CONFORMITY
07
Datalogic Automation S.r.l.
Via S. Vitalino 13
40012 - Lippo di Calderara
Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el
DX6400-XXX-XXX, Laser Scanner; e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: der nachstehend angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
89/336/EEC EMC Directive e et ses successifs amendements
y
2006/95/EC Low Voltage Directive
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti.
On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety.
Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits.
Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen.
Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto.
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
EN 55022 (Class A ITE), August 1994:
Amendment A1 (Class A ITE), October 2000:
L IMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE
CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT
EN 61000-6-2, October 2001: E LECTROMAGNETIC COMPATIBILITY (EMC)
P ART 6-2: G ENERIC S TANDARDS - I MMUNITY FOR INDUSTRIAL
ENVIRONMENTS
EN 60950-1, December 2001: I NFORMATION TECHNOLOGY EQUIPMENT – S AFETY –
P ART 1: G ENERAL R EQUIREMENTS
EN 60825-1, June 1994: S AFETY OF LASER PRODUCTS –
Amendments A11 (1996), A2 (2001): P ART 1: E QUIPMENT CLASSIFICATION , REQUIREMENTS AND USER ' S GUIDE
Lippo di Calderara, April 2nd, 2007 Lorenzo Girotti
Product & Process Quality Manager
821001213 (Rev. D)
Herunterladen
Werbung