Alto EQU MKII series are high-end Graphic Equalizers that provide precise equalization for musicians, performers, and studio engineers. They offer a wide range of capabilities and can be used to modify the frequency response of a sound. With their constant Q circuitry, selectable control range, and balanced and unbalanced input and output connectors, the EQU MKII series equalizers are well-suited for a variety of applications, including live sound reinforcement, recording, and broadcast.
advertisement
LTO
R
User's Manual
EQU MKII SERIES
15/31 BANDS GRAPHIC EQUALIZER
www.altoproaudio.com
Version 1.2 NOV. 2007
English
IMPORTANT SAFETY INSTRUCTION
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
WARNING
To reduce the risk of electric shock and fire, do not expose this equipment to moisture or rain.
7.
8.
TO REDUCE THE RISK OF ELECTRIC SHOCK
PLEASE DO NOT REMOVE THE COVER OR
THE BACK PANEL OF THIS EQUIPMENT.
THERE ARE NO PARTS NEEDED BY USER
INSIDE THE EQUIPMENT. FOR SERVICE,
PLEASE CONTACT QUALIFIED SERVICE
CENTERS.
11.
This symbol, wherever used, alerts you to the presence of un-insulated and dangerous voltages within the product enclosure. These are voltages that may be sufficient to constitute the risk of electric shock or death.
This symbol, wherever used, alerts you to important operating and maintenance instructions.
Please read.
Protective Ground Terminal
AC mains (Alternating Current)
Hazardous Live Terminal
ON: Denotes the product is turned on.
OFF: Denotes the product is turned off.
12.
CAUTION
Describes precautions that should be observed to prevent damage to the product.
1.
Read this Manual carefully before operation.
2.
3.
4.
Keep this Manual in a safe place.
Be aware of all warnings reported with this symbol.
Keep this Equipment away from water and moisture.
5.
Clean it only with dry cloth. Do not use solvent or other chemicals.
6.
Do not damp or cover any cooling opening.
Install the equipment only in accordance with the Manufacturer's instructions.
Power Cords are designed for your safety. Do not remove Ground connections! If the plug does not fit your AC outlet, seek advice from a qualified electrician. Protect the power cord and plug from any physical stress to avoid risk of electric shock. Do not place heavy objects on the power cord. This could cause electric shock or fire.
Unplug this equipment when unused for long periods of time or during a storm.
9.
Refer all service to qualified service personnel only. Do not perform any servicing other than those instructions contained within the
User's Manual.
HOURS X DAY
8
6
4
3
Dispose of this product should not be placed in municipal waste and should be separate collection.
Move this Equipment only with a cart, stand, tripod, or bracket, specified by the manufacturer, or sold with the
Equipment. When a cart is used, use caution when moving the cart / equipment combination to avoid possible injury from tip-over.
Permanent hearing loss may be caused by exposure to \ extremely high noise levels.
The US. Government's Occupational Safety and Health Administration (OSHA) has specified the permissible exposure to noise level.
These are shown in the following chart:
The apparatus shall be connected to a mains socket outlet with a protective earthing connection.
SPL
90
92
95
97
2
1,5
1
0,5
0,25 or less
100
102
105
110
115
EXAMPLE
Small gig train
Subway train
High level desktop monitors
Classic music concert
Rock concert
According to OSHA, an exposure to high SPL in excess of these limits may result in the loss of heat. To avoid the potential damage of heat, it is recommended that Personnel exposed to equipment capable of generating high SPL use hearing protection while such equipment is under operation.
10.
To prevent fire and damage to the product, use only the recommended fuse type as indicated in this manual. Do not short-circuit the fuse holder. Before replacing the fuse, make sure that the product is OFF and disconnected from the AC outlet.
The mains plug or an appliance coupler is used as the disconnect device, the disconnect device shall remain readily operable.
IN THIS MANUAL:
1. INTRODUCTION.........................................................................1
2. FEATURES................................................................................1
3. CONTROL ELEMENTS................................................................2
4. APPLICATION............................................................................7
5. INSTALLATION & CONNECTION...................................................9
6. TECHNICAL SPECIFICATIONS .....................................................12
7. WARRANTY.............................................................................13
1. INTRODUCTION
Thank you for your purchasing the EQU MKII series Graphic Equalizers.
With the EQU MKII series Graphic Equalizers you have acquired extremely musical and flexible Graphic Equalizer. The high-end EQU MKII series are based on many years of experience and are designed to provide a permanent precise equalization to musician, performer, and studio engineer. They can be used wherever is requested to modify the frequency "contour" of a sound and can offer a solution to many common sound problems and allows the user to use the creativity to obtain nice results in terms of sound characterization.
EQU Series Graphic Equalizers include the following seven models:
EQU131-MKII V2 -Graphic Mono 31-Band Equalizer
EQU215-MKII V2 -Graphic Stereo 15-Band Equalizer
EQU215TWIN-MKII -Graphic Stereo 15-Band Equalizer
EQU131VU-MKII -Graphic Mono 31-Band Equalizer/VU Meter 1
EQU231VU-MKII V2 -Graphic Stereo 31-Band Equalizer/VU Meter 2
EQU231-MKII V2 -Graphic Stereo 31-Band Equalizer
EQU231TWIN-MKII V2 -Graphic Stereo 31-Band Equalizer
Enjoy your EQU MKII and make sure to read this Manual carefully before operation.
2. FEATURES
Constant Q circuitry with a 3% center frequency accuracy
Control range 6 dB/ 12 dB selectable
Active balanced and unbalanced input and output connectors
Variable input level control
Signal clip pilot
Ground "LIFT" switch to disconnect signal ground from chassis ground
Power off automatic bypass function
Line voltage selectable
Robust and compact design
Mountable in a 19" rack unit(1U)
Manufactured Under QS9000, VDA6.1 certified management system
1
SPO
TLIGHT
3. CONTROL ELEMENTS
Front panel
EQU131-MKII V2
2 12 5
8
7
6
10
LTO
R
20 25 31.5
40 50 63
31 Band Graphic Equalizer
+12
INPUT
LEVEL
+6 +12
80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K 5K 6.3K
0 0dB
8K 10K 12.5K
16K 20K
-12 - 6 -12
INPUT
SIG CLIP
6 12 40Hz
OUTPUT
SIG CLIP
16KHz ON
RANGE HI
PASS
LOW
PASS
EQ
EQU131
MK V2
1 11 3 4 9
EQU215-MKII V2
8
7 4
R
LTO
25
Dual 15 Band Graphic Equalizer
40
63 100
160
250 400
630
1K 1.6K
2.5K
4K 6.3K
10K
Channel One
+12 +6 +12
INPUT OUTPUT
SIG CLIP SIG CLIP
40Hz 16KHz
0 0dB
HI-PASS LOW-PASS
6 12
ON
16K
-12 -12
LEVEL RANGE EQ
25
40
63 100
160
250 400
630
1K 1.6K
2.5K
4K 6.3K
10K
Channel Two
+12 +6 +12
0 0dB
16K
-12 - 6 -12
LEVEL
INPUT OUTPUT
SIG CLIP SIG CLIP
40Hz 16KHz
HI-PASS LOW-PASS
6 12
ON
EQU215
MK V2
RANGE EQ
1
5
6
1
2
3
12
11
9
10
EQU215TWIN-MKII
LTO
R
Dual 15 Band Graphic Equalizer
3
8
7
4
Channel One
+12 +6 +12
INPUT OUTPUT
SIG CLIP SIG CLIP
5
6
Channel Two
+12 +6 +12 INPUT OUTPUT
SIG CLIP SIG CLIP
0 0dB
40Hz 16KHz
EQU215TWIN
MK
HI-PASS LOW-PASS
0 0dB
40Hz 16KHz
HI-PASS LOW-PASS
25 40 63 100 160 250 400 630 1K 1.6K
2.5K
4K 6.3K
10K
6 12
16K
-12 - 6 -12
INPUT
LEVEL
RANGE
ON
EQ
1 2 11
12
9
10
25 40 63 100 160 250 400 630 1K 1.6K
2.5K
4K 6.3K
6 12
10K 16K
-12 - 6 -12
INPUT
LEVEL
RANGE EQ
ON
1
2
EQU131VU-MKII
5
8 13 7 6
OUTPUT
31 Band Graphic Equalizer
+12 +6 +12
LTO
R
0 0dB
20 25 31.5
40 50 63 80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K 5K 6.3K
8K 10K 12.5K
16K 20K
-12 - 6 -12
INPUT
LEVEL
R
LTO
POWER OUTPUT
INPUT
SIG CLIP
OUTPUT
SIG CLIP
6 12 40Hz 16KHz ON
RANGE HI
PASS
LOW
PASS
EQ
EQU131VU
MK
1 2
12
11
3
4
9
10
2
SPO
TLIGHT
3. CONTROL ELEMENTS
EQU231VU-MKII V2
20 25 31.5
40 50 63
LTO
R
20 25 31.5
40 50 63
7
1
3
2
5
8
6
4
80 100 125 160 200 250 315 400
80 100 125 160 200 250
Dual 31 Band Graphic Equalizer
315 400
500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K
500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K
5K 6.3K
5K 6.3K
8K
8K
10K 12.5K
16K 20K
+12
INPUT
LEVEL
+6 +12
INPUT OUTPUT
SIG CLIP SIG CLIP
40Hz 16KHz
Channel One
Channel Two
-12 - 6
0dB
-12
HI-PASS LOW-PASS
6 12 ON
+12 +6 +12
RANGE EQ
INPUT OUTPUT
SIG CLIP SIG CLIP
40Hz 16KHz
0dB
HI-PASS LOW-PASS
6 12 ON
10K 12.5K
16K 20K
-12 - 6 -12
INPUT
LEVEL
RANGE EQ
OUTPUT
20
10
6 3 0
3
5
50 100
VU
LTO
R
POWER OUTPUT
OUTPUT
20
10
6 3
50 100
VU
0
3
5
EQU231VU
MK V2
LTO
R
POWER OUTPUT
11 9 13
12
10
EQU231-MKII V2
12
8
5
7
6
20
20
25
25
31.5
31.5
40
40
50
50
63
63
80
80
100
100
125
125
160
160
200
200
250
250
315
315
400
400
500
500
630
630
800
800
1K
1K 1.25K
1.6K
1.25K
1.6K
2K
2K 2.5K
2.5K
3.15K
3.15K
4K
4K
5K
5K 6.3K
6.3K
8K
8K 10K
10K
12.5K
12.5K
16K
16K
20K
20K
+12
INPUT
LEVEL
+6 +12
0 0dB
LTO
R
Dual 31 Band Graphic Equalizer
-12 - 6 -12
Channel One
Channel Two
+12 +6 +12
0 0dB
20 25 31.5
40 50 63 80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K 5K 6.3K
8K 10K 12.5K
16K 20K
-12 - 6 -12
INPUT
LEVEL
INPUT OUTPUT
SIG CLIP
6 12 40Hz
SIG CLIP
16KHz ON
RANGE HI
PASS
LOW
PASS
EQ
INPUT OUTPUT
SIG CLIP
6 12 40Hz
SIG CLIP
16KHz ON
RANGE HI
PASS
LOW
PASS
EQ
1
2
11
3
4
9
10
EQU231
MK V2
EQU231TWIN-MKII V2
5
3
20 25 31.5
40 50 63 80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K 5K 6.3K
8K 10K 12.5K
16K 20K
+12
INPUT
LEVEL
+6 +12
0 0dB
SIG
INPUT
CLIP
6 12 40Hz
6
OUTPUT
SIG CLIP
16KHz ON
4
LTO
R
Dual 31 Band Graphic Equalizer
RANGE HI-PASS
-12 - 6
Channel One
Channel Two
+12 +6
-12
+12
0
SIG
INPUT
CLIP
0dB
6 12 40Hz
LOW-PASS EQ
OUTPUT
EQU231TWIN
MK V2
SIG CLIP
16KHz ON
20 25 31.5
40 50 63 80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K 5K 6.3K
8K 10K 12.5K
16K 20K
-12 - 6 -12
INPUT
LEVEL
RANGE HI-PASS LOW-PASS EQ
2
11 7 8 9 10
1
12
1 Filter level controls
Each one of these linear potentiometers will boost or attenuate (either 6dB or
12 dB) the selected frequency at a preset bandwidth. When all the sliders are in the centre position, the output of the equalizer is flat response.
3
SPO
TLIGHT
3. CONTROL ELEMENTS
2 Level control
This control sets the input signal level of the equalizer. The "0 dB" position is unity gain (no boost or attenuation). If the clip LED (5) lights continuously, turn down this control until it only blinks occasionally.
3 High-pass Filter
This button electronically inserts a filter into the signal path, which cuts the low frequencies at 40 Hz (12 dB per octave). The LED (12) indicator lights up when the button is pressed and this filter is serving in the circuit.
4 Low-pass Filter
This button electronically inserts a filter into the signal path, which cuts the high frequencies at 16 K (12 dB per octave). The LED (13) indicator lights up when the button is pressed and this filter is serving in the circuit.
5
High-pass LED
When the High pass filter (40 Hz/12 dB) is actived, this LED will light up.
6
Low-pass LED
When the Low pass filter (16 kHz/12 dB) is actived, this LED will light up.
7
Clip LED
This LED will light up when any section of the equalizer is within 5 dB of clipping. Occasional blinking of this clip LED is acceptable, but if it remains on continuously, you should turn down the level control or reduce the output level of the preceding component to avoid audible distortion.
8
Signal LED
This green LED will light up when any signal appears at Input/Output stage.
9
EQ switch
This switch inserts or removes the equalizer to channel path. If press this switch, the EQ LED (8) will be illuminated, which means it is in EQ mode. When release this switch, the input signal is routed directly into the output jacks, which means it is in bypass mode.
10 EQ LED
When this LED lights up, it is in EQ mode.
11
Range switch
This button switches the gain range of the filter slider between 6 dB and 12 dB.
12
Filter range indicator
When the 6 dB range is selected, green LED will light up. When the 12 dB range is selected, red LED will light up.
13
VU Meter (Only for EQU131VU-MKII/231VU-MKII V2)
This VU meter is used to indicate the output level.
4
SPO
TLIGHT
3. CONTROL ELEMENTS
The rear panel
EQU131-MKII V2
19
ON
POWER
OFF
14
MODEL
SERIAL
AC INPUT
95-120V /210-240V 60-50Hz
Rated Power Consumption 9W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T160mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk
18
LIFT
GND
UNBALANCED
OUTPUT
BALANCED
17
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
16 15
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
UNBALANCED
INPUT
BALANCED
PUSH
NEW TIDE
3
2 1
17 16 15
EQU215-MKII V2
19
AC INPUT
95-120V /210-240V 60-50Hz
Rated Power Consumption 9W
ON
FUSE:
210-240V: T100mAL 250VAC
95-120V: T160mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk
OFF
POWER
LIFT
GND
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
UNBALANCED
OUTPUT
BALANCED
CHANNEL 2
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
INPUT
BALANCED
14 18 17 16 15 17 16 15
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
CHANNEL 1
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
UNBALANCED
OUTPUT
BALANCED UNBALANCED
INPUT
BALANCED
EQU215TWIN-MKII
19
ON
POWER
OFF
MODEL
SERIAL
AC INPUT
95-120V /210-240V 60-50Hz
Rated Power Consumption 9W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T160mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
UNBALANCED
OUTPUT
BALANCED
CHANNEL 2
UNBALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
INPUT
BALANCED
LIFT
GND
14 18 17 16 15 17 16 15
EQU131VU-MKII
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
CHANNEL 1
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
UNBALANCED
OUTPUT
BALANCED UNBALANCED
INPUT
BALANCED
ON
POWER
OFF
MODEL
SERIAL
AC INPUT
95-120V /210-240V 60-50Hz
Rated Power Consumption 9W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T160mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
LIFT
GND
UNBALANCED
OUTPUT
BALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
UNBALANCED
INPUT
BALANCED
19 14
EQU231VU-MKII V2/EQU231-MKII V2
ON
POWER
OFF
MODEL
AC INPUT
95-120V /210-240V 60-50Hz
Rated Power Consumption 18W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T200mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk
SERIAL
18
19
14
17 16
15
17 16
15
18
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
CHANNEL 1
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
UNBALANCED
OUTPUT
BALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
UNBALANCED
CHANNEL 2
INPUT
BALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
LIFT
GND
UNBALANCED
OUTPUT
BALANCED UNBALANCED
INPUT
BALANCED
17
16
15
17
16 15
5
SPO
TLIGHT
3. CONTROL ELEMENTS
EQU231TWIN-MKII V2
ON
POWER
OFF
MODEL
AC INPUT
95-120V /210-240V 60-50Hz
Rated Power Consumption 18W
FUSE:
210-240V: T100mAL 250VAC
95-120V: T200mAL 250VAC
REPLACE FUSE WITH CORRECT
TYPE ONLY
Apparaten skall anslutas till jordat uttag nar den ansluts till ett natverk
SERIAL
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
CHANNEL 1
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
UNBALANCED
OUTPUT
BALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
UNBALANCED
CHANNEL 2
INPUT
BALANCED
TIP/PIN 2
RING/PIN 3
SLEEVE/PIN 1
PUSH
LIFT
GND
UNBALANCED
OUTPUT
BALANCED UNBALANCED
INPUT
BALANCED
19 14 18 17 16 15 17 16 15
14 Power switch
It switches the unit ON and OFF.
15 XLR IN/OUT connectors
The XLR connectors are balanced and are used to Input/Output the signal.
16 1/4" TRS phone IN/OUT connectors
The 1/4" TRS connector are balanced and are used to Input/Output the signal.
17 RCA IN/OUT connectors
The RCA connectors are unbalanced.
NOTE: While you can use any input connector with any output connector, only one set of these connectors is to be used at one time (The wiring and connection, details please refer to 5.2 audio connection).
18 Ground lift switch
This switch is used to disconnect the signal ground from the mains and chassis earth. If it is determined that the equalizer is the cause of hum or buzz in your system due to a ground loop, move this switch to "lift" position.
19 AC Inlet/Fuse holder
Standard IEC receptacle. Connect your equalizer an AC socket with the supplied power cord. Before powering up your equalizer for the first time, make certain the stated power requirement of the unit matches the voltage supplied by the
AC socket.
If the fuse blows, replaced with a fuse of the correct type only.
6
4. APPLICATION
4.1 The Sound Frequency
In recording studios as well as stage or radio plays, the equalizer will give you a perfect contour of your sound. But first of all, you should clarify the typical frequency of each instrument and voice, so that you can obtain nice results in terms of sound characterization. The following table will give you an idea of specific frequencies and their acoustic significance.
Typical Frequency of Each Instrument and Voice
Mid C
CDEFGABCDEFGABCDEFGABCDEFGABCDEFGABCDEFGABCDEFGABCDEFGABCDEFGABC
25 31 40 50 62 80 100 125 160 200 250 320 400 500 640 800 1K 1.3K 1.6K
2K 2.5K 3.1K
4K 5K 6.2K
8K 10K 13K 16K 20K
25 31 40 50 62 80 100 125 160 200 250 320 400 500 640 800 1K 1.3K
1.6K
2K 2.5K
3.1K
4K 5K 6.2K
8K 10K 13K 16K 20K
Human hearing range
Vocal
Soprano
Contralto
Baritone
Bass
WOODWIND
Piccolo
Flute
Oboe
Clarinet in B flat or A
Clarinet in E flat
Bass Clarinet
Basset Horn
Cor Anglais
Bassoon
Double Bassoon
Brass
Soprano Saxophone
Alto Saxophone
Tenor Saxophone
Baritone Saxophone
Bass Saxophone
Trumpet in C
Trumpet in F
Alto Trombone
Tenor Trombone
Bass Trombone
Tuba
Valve Horn
STRINGS
Violin
Viola
Cello
Double Bass
Guitar
KEYBOARDS
Pianoforte
Organ
PERCUSSION
Celesta
Timpani
Xylophone
FREQUENCY
7
4. APPLICATION
4.2 Application on
line instrument
The EQU MKII Series Graphic Equalizer can be used on an entire mix "In-line" between a instrument outputs and a power amplifier, and this is the basic application in the PA system to offer precise equalization control.
CH1 IN
CH2 IN
From line instrument outputs
CH1 OUT
CH2 OUT
To power amplifier inputs
20 25 31.5
40 50
R
LTO
20 25 31.5
40 50
63 80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K 5K 6.3K
8K 10K 12.5K
16K 20K
+12
INPUT
LEVEL
+6 +12
0 0dB
-12 - 6 -12
Dual 31 Band Graphic Equalizer
Channel One
Channel Two
63 80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K
+12 +6 +12
5K 6.3K
8K 10K 12.5K
16K
0 0dB
20K
-12 - 6 -12
INPUT
LEVEL
INPUT
SIG CLIP
6 12 40Hz
OUTPUT
SIG CLIP
16KHz ON
RANGE HI
PASS
LOW
PASS
EQ
INPUT
SIG CLIP
6 12 40Hz
OUTPUT
SIG CLIP
16KHz ON
RANGE HI
PASS
LOW
PASS
EQ
EQU231
MK V2
4.3 Mixing Console
The EQU MKII Series Graphic Equalizer can also be used on a single instrument by connecting to a mixing console's main inserts, especially for those consoles without built-in equalization circuitry.
Main Inserts 2
Main Inserts 1
Send 2
Send 1
CH2 OUT
CH1 OUT
CH2 IN
CH1 IN
20 25 31.5
40 50 63 80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K
LTO
R
Dual 31 Band Graphic Equalizer
20 25 31.5
40 50 63 80 100 125 160 200 250 315 400 500 630 800 1K 1.25K
1.6K
2K 2.5K
3.15K
4K
5K 6.3K
8K 10K 12.5K
16K 20K
+12
INPUT
LEVEL
+6 +12
0
-12 - 6
0dB
-12
Channel One
Channel Two
+12 +6 +12
5K 6.3K
8K 10K 12.5K
16K
0 0dB
20K
-12 - 6 -12
INPUT
LEVEL
INPUT OUTPUT
SIG CLIP
6 12 40Hz
SIG CLIP
16KHz ON
RANGE HI
PASS
LOW
PASS
EQ
INPUT OUTPUT
SIG CLIP
6 12 40Hz
SIG CLIP
16KHz ON
RANGE HI
PASS
LOW
PASS
EQ
EQU231
MK V2
NOTE: Mono/Stereo Application a . For mono application, please use the
EQU131VU-MKII
EQU131-MKII V2 mono Graphic Equalizer.
, b
. For stereo application, please use the
EQU215-MKII V2,
EQU215TWIN-MKII, EQU231-MKII V2, EQU231VU-MKII or EQU231TWIN-MKII V2 stereo Graphic Equalizer, either of the two channels can be used as L/R input & output.
8
5. INSTALLATION AND CONNECTION
Ok, you have got to this point and you are now in the position to operate your equalizer successfully. However, we advise you to read carefully the following section to be real master of your own equalizer. Not paying attention enough to the input signal level, to the routing of the signal and the assignment of the signal will result in unwanted distortion, a corrupted signal or no sound at all.
So you should follow this procedure for every single channel:
5.1 Mains Connection
Please ensure that the equalizer is set to the correct supply voltage before plugging the power cord into the wall outlet, use the same fuse as marked on the fuse holder at the AC power connection socket. The mains connections of the EQU MKII Series Graphic Equalizer is made by using the enclosed mains cord and a standard IEC receptacle. It meets all of the international safety certification requirements.
5.2 Audio Connection
The equalizer presents with balanced XLR and 1/4" TRS and unbalanced RCA connectors. It can be interfaced in several ways to support a variety of applications without any signal loss. The equalizer can be used on a single instrument by connecting to the mixing console's main inserts, or on an entire mix "in-line" between a mixing console's outputs and a power amplifier. The defective wiring may degrade the performance of equalizer, so please use good quality screened audio cables only. Please follow the guide below to interface equalizer without experiencing any noise or signal loss.
Ring=Right Signal
Sleeve
Tip
Ring
Strain Clamp
Tip=Left Signal
Sleeve=Ground/Screen
Use for Headphone
1/4" Stereo (TRS) Jack Plug
Sleeve
Tip
Strain Clamp Tip=Signal
Sleeve=Ground/Screen
Use for Mono Line In, Mono 1/4" Jack Plugs
1/4" Mono (TS) Jack Plug
9
10
5. INSTALLATION AND CONNECTION
Strain Clamp
Sleeve
Tip
Ring
Ring=Return Signal
Tip=Send Signal
Sleeve=Ground/Screen
Use for Insert Points
1/4" Stereo (TRS) Jack Plug
TIP RING SLEEVE
TIP RING SLEEVE
TIP RING SLEEVE
2=Hot(+)
2
3
1
1=Ground/Screen
3=Cold(-)
Use for Balanced Mic Inputs
(For unbalanced use, connect pin 1 to 3)
3-pin XLR Male Plug
(seen from soldering side)
2=Hot(+)
2
3
1
1=Ground/Screen
3=Cold(-)
Use for Main output
(For unbalanced use, leave pin3 unconnected)
3-pin XLR Line Socket
(seen from soldering side)
SLEEVE TIP
SLEEVE RING TIP
Tip
Ring
Sleeve
Tip
Ring
Sleeve
Tip
Ring
Sleeve
Insert Leads
Tip (Send)
Sleeve
Tip (Return)
Sleeve
1
2 (Send)
3
1
2 (Return)
3
Centre (Send)
Screen
Centre (Return)
Screen
5. INSTALLATION AND CONNECTION
5.3 Line Connection
For these applications the EQU MKII Series Graphic Equalizers provide 1/4"
TRS connector, XLR connectors and RCA connectors to easily interface with most any professional audio device. Follow the configuration examples below for your particular connection.
Banlanced
TIP RING SLEEVE SLEEVE RING TIP
Tip
Ring
Sleeve
Tip
Ring
Sleeve
1
2
3
1
2
3
1
2
3
Tip
Ring
Sleeve
TIP RING SLEEVE
Unbalanced
TIP RING SLEEVE
TIP SLEEVE
TIP SLEEVE
TIP RING SLEEVE
TIP SLEEVE
TIP RING SLEEVE
SLEEVE TIP
SLEEVE RING TIP
Tip
Ring
Sleeve
Tip
Sleeve
Tip
Sleeve
1
2
3
Tip
Ring
Sleeve
Tip
Sleeve
Tip
Ring
Sleeve
1
2
3
1
2
3
1
2
3
Centre
Screen
Tip
Sleeve
Tip
Ring
Sleeve
Centre
Screen
1
2
3
Centre
Screen
11
12
6. TECHNICAL SPECIFICATION
Type
EQU231VU-MKII V2
EQU231-MKII V2
EQU231TWIN-MKII V2
EQU131VU-MKII
EQU131-MKII V2
EQU215-MKII V2
EQU215TWIN-MKII
Slider travel
Range
Input connections
Input impedance
Maximum input level
Output connections
Output impedance
High pass filter
Low pass filter
Frequency response
THD + N%
S/N ration
Power supply
Consumption
EQU231VU-MKII
EQU231-MKII V2
EQU231TWIN-MKII V2
EQU131VU-MKII V2
EQU131-MKII V2
EQU215-MKII V2
EQU215TWIN-MKII
Dimension
2 31-Band: 1/3 octave, ISO spacing(2H series)
2 31-Band: 1/3 octave, ISO spacing(2H series)
2 31-Band: 1/3 octave, ISO spacing(3H series)
1 31-Band: 1/3 octave, ISO spacing(2H series)
1 31-Band: 1/3 octave, ISO spacing(1H series)
2 15-Band: 2/3 octave, ISO spacing(1H series)
2 15-Band: 2/3 octave, ISO spacing(2H series)
20 mm with positive centre detent
(EQU231-MKII V2/EQU231VU-MKII V2/EQU131-MKII V2/EQU215-MKII V2)
45 mm with positive centre detent(Only for EQU231TWIN-MKII V2)
60 mm with positive centre detent(EQU131VU-MKII /EQU215TWIN-MKII)
6 dB or 12 dB selectable
Active balanced XLR and 1/4" TRS
Unbalanced RCA
20 k (bal.)
15 k (unbal.)
14 dBu
Active balanced XLR and 1/4" TRS
Unbalanced RCA
<600
40 Hz(12 dB/oct) fixed-button type
16 kHz(12 dB/oct) fixed-button type
20 Hz to 50kHz at -1.5 dBu
110 dB
95V-120VAC-60 Hz
220V-240VAC-50 Hz/60 Hz
2 31 Band: 1/3 octave, ISO spacing:18 W
2 31 Band: 1/3 octave, ISO spacing:18 W
2 31 Band: 1/3 octave, ISO spacing:18 W
1 31 Band: 1/3 octave, ISO spacing:9 W
1 31 Band: 1/3 octave, ISO spacing:9 W
2 15 Band: 2/3 octave, ISO spacing:9 W
2 15 Band: 2/3 octave, ISO spacing:9 W
483(W) 220(D) 44(H)(19" 8.66" 1.7")mm (1H series)
483(W) 220(D) 88(H)(19" 8.66" 3.5")mm (2H series)
483(W) 220(D) 132(H)(19" 8.66" 5.1")mm (3H series)
7. WARRANTY
1. WARRANTY REGISTRATION CARD
To obtain Warranty Service, the buyer should first fill out and return the enclosed
Warranty Registration Card within 10 days of the Purchase Date.
All the information presented in this Warranty Registration Card gives the manufacturer a better understanding of the sales status, so as to provide a more effective and efficient after-sales warranty service. Please fill out all the information carefully and genuinely, miswriting or absence of this card will void your warranty service.
2. RETURN NOTICE
2.1 In case of return for any warranty service, please make sure that the product is well packed in its original shipping carton, and it can protect your unit from any other extra damage.
2.2 Please provide a copy of your sales receipt or other proof of purchase with the returned machine, and give detail information about your return address and contact telephone number.
2.3 A brief description of the defect will be appreciated.
2.4 Please prepay all the costs involved in the return shipping, handling and insurance.
3. TERMS AND CONDITIONS
3.1
LTO warrants that this product will be free from any defects in materials and/or workmanship for a period of 1 year from the purchase date if you have completed the Warranty Registration Card in time.
3.2 The warranty service is only available to the original consumer, who purchased this product directly from the retail dealer, and it can not be transferred.
3.3 During the warranty service, LTO may repair or replace this product at its own option at no charge to you for parts or for labor in accordance with the right side of this limited warranty.
3.4 This warranty does not apply to the damages to this product that occurred as the following conditions:
Instead of operating in accordance with the user's manual thoroughly, any abuse or misuse of this product.
Normal tear and wear.
The product has been altered or modified in any way.
Damage which may have been caused either directly or indirectly by another product / force / etc.
Abnormal service or repairing by anyone other than the qualified personnel or technician.
And in such cases, all the expenses will be charged to the buyer.
3.5 In no event shall LTO be liable for any incidental or consequential damages.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you.
3.6 This warranty gives you the specific rights, and these rights are compatible with the state laws, you may also have other statutory rights that may vary from state to state.
13
SEIKAKU TECHNICAL GROUP LIMITED
NO. 1, Lane 17, Sec. 2, Han Shi West Road, Taichung 40151, Taiwan http://www.altoproaudio.com Tel: 886-4-22313737 email: [email protected] Fax: 886-4-22346757
All rights reserved to ALTO. All features and content might be changed without prior notice. Any photocopy, translation, or reproduction of part of this manual without written permission is forbidden. Copyright c
2007 Seikaku Group
NF01783-1.2
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Key Features
- Constant Q circuitry with 3% center frequency accuracy
- Selectable control range of 6 dB or 12 dB
- Active balanced and unbalanced input and output connectors
- Variable input level control
- Signal clip pilot
- Ground lift switch
- Power off automatic bypass function
- Line voltage selectable
- Rack mountable
- Manufactured under QS9000, VDA6.1 certified management system
Related manuals
Frequently Answers and Questions
What is the purpose of the ground lift switch?
What is the benefit of the power off automatic bypass function?
What is the line voltage selectable feature?
Is the equalizer rack mountable?
advertisement