Datalogic PowerScan PM9500 Product Reference Guide
โฆษณา
โฆษณา
PowerScan™ 9500 Family
Industrial Corded Handheld
Area Imager Bar Code Reader
PowerScan PD9530/PBT9500/PM9500
Product Reference Guide
Datalogic ADC, Inc.
959 Terry Street | Eugene | OR 97402 | USA
Telephone: (1) 541-683-5700 | Fax: (1) 541-345-7140
©2013 Datalogic, Inc.
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates
("Datalogic" or “Datalogic ADC”). Owners of Datalogic products are hereby granted a nonexclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic representative. Electronic versions may either be downloadable from the Datalogic website (www.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other brand and product names may be trademarks of their respective owners.
Patents
This product may be covered by one or more of the following patents:
Design Patents: AU344427; AU344428; AU344429; EP1970237; USD682277;
ZL201230284676.X
Utility Patents: EP996284; EP999514; EP1128315; EP1172756; EP1396811; EP1413971;
EP1828957; JP4435343; US5481098; US6478224; US6512218; US6513714; US6561427;
US6808114; US6877664; US6997385; US7053954; US7234641; US7387246; US7721966.
Additional patents pending.
Table of Contents
Product Reference Guide i
Contents
ii PowerScan™ PD9530/PBT9500/PM9500
Contents
Product Reference Guide iii
Contents iv
PowerScan™ PD9530/PBT9500/PM9500
Contents
Product Reference Guide v
Contents
vi PowerScan™ PD9530/PBT9500/PM9500
Contents
Product Reference Guide vii
Contents
viii PowerScan™ PD9530/PBT9500/PM9500
Chapter 1
Introduction
About this Manual
This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual.
Overview
(this chapter) presents information about manual conventions, and an overview of the reader, its features and operation.
Chapter 2, Setup presents information about unpacking, cable connection
information and setting up the reader.
Chapter 3, Configuration Using Bar Codes provides instructions and bar
code labels for customizing your reader. There are different sections for interface types, general features, data formatting, symbology-specific and model-specific features.
provides background information and detailed instructions for more complex programming items.
Chapter 5, Message Formatting gives details for programming options.
Appendix A, Technical Specifications lists physical and performance charac-
teristics, as well as environmental and regulatory specifications. It also provides standard cable pinouts and LED/Beeper functions.
Appendix B, Sample Bar Codes offers sample bar codes for several common
symbologies.
Appendix C, Standard Defaults references common factory default settings
for reader features and options.
Appendix D, Keypad includes numeric bar codes to be scanned for certain
parameter settings.
Appendix E, Scancode Tables lists control character emulation information
for Wedge and USB Keyboard interfaces.
Product Reference Guide 1
2
Introduction
Manual Conventions
The following conventions are used in this document:
The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader:
Notes contain information necessary for properly diagnosing, repairing and operating the reader.
CAUTION
The CAUTION symbol advises you of actions that could damage equipment or property.
References
Current versions of this Product Reference Guide (PRG), Quick Reference
Guide (QRG), the Datalogic Aladdin™ Configuration application, and any other manuals, instruction sheets and utilities for this product can be downloaded from the website listed below. Alternatively, printed copies or product support CDs for most products can be purchased through your Datalogic reseller.
Technical Support
Datalogic Website Support
The Datalogic website ( www.datalogic.com
) is the complete source for technical support and information for Datalogic products. The site offers product support, warranty information, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair.
Reseller Technical Support
An excellent source for technical assistance and information is an authorized Datalogic reseller. A reseller is acquainted with specific types of businesses, application software, and computer systems and can provide individualized assistance.
Telephone Technical Support
If you do not have internet or email access, you may contact Datalogic technical support at (541) 349-8283 or check the back cover of your manual for more contact information.
PowerScan™ PD9530/PBT9500/PM9500
About the Reader
About the Reader
The PowerScan 2D is a family of feature-rich and rugged area image readers.
It is offered in several different models to better fit the different needs of each customer.
The main model categories are:
• PD9530-XX: Corded models.
• PM9500-XX: STAR-System(tm) models.
• PBT9500-XX: Bluetooth models.
Within each category, further differentiating features are available, described by the part number suffix:
• D: models equipped with display
• DPM: models with laser, ink jet and dot peen reading capability
• HP: models with autofocus optic
Typically, units are factory-programmed for the most common terminal and communications settings. If you need to modify any programmable settings, custom configuration can be done by scanning the programming barcodes within this guide or with Datalogic Aladdin™, available from the Datalogic website. See
"Datalogic Aladdin™" on page 6 for more information.
Advancements in the LED technology used in the imager-based readers significantly improve the illumination of the target field of view, resulting in higher scan efficiency. Whether used in Single Trigger or Continuous Mode, the ergonomic design of the reader will help to promote comfortable handling during extended periods of use.
In addition, the reader can be set up to read and output data from USA
Driver License PDF417 bar codes. For more information reference the USA
Driver License Parsing Quick Reference Guide (QRG), available on the Datalogic website.
See
"Interface Selection" on page 14 for a listing and descriptions of avail-
able interface sets by model type.
PM8500 Compatible Mode:
Powerscan PM9500 offers a limited set of features compatible with the previous PM8500 family. To access those features, you have to program the system through the Compatibility Mode parameter (see
"Compatibility mode" on page 238 of the Wireless Configuration chapter).
When in normal mode, the same parameter can be used to configure the communication speed.
Product Reference Guide 3
4
Introduction
The BC9xx0™ Base Station/Charger
The BC9xx0 base station, when paired with one or more PowerScan™ 9500 readers, builds a Cordless Reading System for the collection, decoding and transmission of bar code data. It can be connected to a Host PC via RS-232,
USB, or KBD Wedge, and is suited for single-cradle layouts. The BC91x0 models also provide a spare battery charger slot.
The label on the cradle contains LED indicators and a multi-function button.
When the button is pressed for less than 5 seconds, the cradle will transmit a
"broadcast" message." When the broadcast is sent, all properly configured scanners (Radio RX Timeout set to keep the radio "awake") that are linked to that base and within radio range coverage will emit a beep and blink within 5 seconds. This functionality is useful to:
• verify which scanners are linked to a certain base station
• detect a scanner forgotten somewhere
When the button is pressed for longer than 5 seconds, all paired scanners will be unpaired.
The LEDs signal the BC9xx0-BT status, as shown in Table 1 on page 4 .
Table 1. LED Status
LED
Aux
Host
Reader
Spare
(BC91x0 models only)
STATUS
Yellow On = BC9xx0 is powered through an external power supply.
Yellow On = BC9xx0 is powered by the Host.
Green On = the reader battery is completely charged.
Red On = the reader battery is charging.
Orange Blinking = reader battery fault - replace battery.
Red / Green Alternatively Blinking = charging error - see "
.
Off = reader not in the cradle or not properly inserted.
Green On = the spare battery is completely charged.
Orange Blinking = spare battery fault - replace spare battery.
Red/Green Alternatively Blinking = charging error - see "
.
Off = no spare battery in the housing or battery not fully inserted.
Yellow Blinking = radio activity.
Radio
Ethernet
(Ethernet models only)
Green Blinking = Ethernet activity.
See " Base Station Indications (Cordless Models ONLY)" on page 304
for more specific details on the LEDs.
PowerScan™ PD9530/PBT9500/PM9500
Battery Safety
Battery Safety
To reinstall, charge and/or perform any other action on the battery, follow the instructions in this manual.
Before installing the Battery, read “Battery Safety” on this and the following pages. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance.
WARNING
CAUTION
Do not discharge the battery using any device except for the scanner. When the battery is used in devices other than the designated product, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury.
Lithium-ion battery packs may get hot, explode or ignite and cause serious injury if exposed to abusive conditions. Be sure to follow the safety warnings listed below:
• Do not place the battery pack in fire or heat.
• Do not connect the positive terminal and negative terminal of the battery pack to each other with any metal object (such as wire).
• Do not carry or store the battery pack together with metal objects.
• Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks.
• Do not solder directly onto the battery pack.
• Do not expose the battery pack to liquids, or allow the battery to get wet.
• Do not apply voltages to the battery pack contacts.
In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye.
Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye.
Always charge the battery at 32° – 104°F (0° - 40°C) temperature range.
Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the device and void your warranty.
Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.
Do not place the battery in or near fire, on stoves or other high temperature locations.
Do not place the battery in direct sunlight, or use or store the battery inside cars in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy.
Do not place the battery in microwave ovens, high-pressure containers or on induction cookware.
Immediately discontinue use of the battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes color or shape, or appears abnormal in any other way.
Do not replace the battery pack when the device is turned on.
Do not remove or damage the battery pack’s label.
Do not use the battery pack if it is damaged in any part.
Battery pack usage by children should be supervised.
As with other types of batteries, Lithium-Ion (LI) batteries will lose capacity over time. Capacity deterioration is noticeable after one year of service whether the battery is in use or not. It is difficult to precisely predict the finite life of a LI battery, but cell manufacturers rate them at 500 charge cycles. In other words, the batteries should be expected to take 500 full dis-
Product Reference Guide 5
Introduction charge / charge cycles before needing replacement. This number is higher if partial discharging / recharging is adhered to rather than full / deep discharging,
The typical manufacturer advertised useful life of LI batteries is one to three years, depending on usage and number of charges, etc., after which they should be removed from service, especially in mission critical applications.
Do not continue to use a battery that is showing excessive loss of capacity, it should be properly recycled / disposed of and replaced. For most applications, batteries should be replaced after one year of service to maintain customer satisfaction and minimize safety concerns.
Collect and recycle waste batteries separately from the device in compliance with European Directive 2006/66/EC, 2011/65/EU, 2002/96/EC and 2012/
19/EU and subsequent modifications, US and China regulatory and others laws and regulations about the environment.
Programming the Reader
Configuration Methods
Programming Bar Codes
The reader is factory-configured with a standard set of default features.
After scanning the interface bar code, you can select other options and customize your reader through use of the instructions and programming bar code labels available in the corresponding features section for your inter-
face. Customizable settings for many features are found in "Configuration
Parameters" starting on page 21.
Some programming labels, like
"Restore Custom Defaults" on page 18,
require only the scan of the single label to enact the change. Most, however, require the reader to be placed in Programming Mode prior to scanning them. Scan an ENTER/EXIT bar code once to enter Programming Mode. Once the reader is in Programming Mode, scan a number of parameter settings before scanning the ENTER/EXIT bar code a second time, which will then accept your changes, exit Programming Mode and return the reader to normal operation.
There are some exceptions to the typical programming sequence described above. Please read the description and setting instructions carefully when configuring each programmable feature.
6
Datalogic Aladdin™
Datalogic Aladdin™ is a multi-platform utility program providing a quick and user-friendly configuration method via the RS-232/USB-COM interface.
Aladdin allows you to program the reader by selecting configuration commands through a user-friendly graphical interface running on a PC. These commands are sent to the reader over the selected communication interface, or they can be printed as bar codes to be scanned. Aladdin also facilitates image capturing.
In addition, Aladdin makes it easy to upgrade the handheld’s firmware, to attain the benefits of new reader features. Reference the Datalogic Aladdin™
Online Help for more details.
Aladdin is available for download free of charge on the Datalogic website.
PowerScan™ PD9530/PBT9500/PM9500
Chapter 2
Setup
Unpacking
Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Dat-
alogic Technical Support. Information is shown on page 2
.
KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.
Setting Up the Reader
Follow the steps below to connect and get your reader up and communicating with its host.
1. Begin by Installing the Interface Cable (Corded) or Connecting the Base
Station (Bluetooth and STAR)
2. Configure Interface Settings (see
3. Configure the Reader starting on page 17 (optional, depends on set-
tings needed)
Connect the PowerScan by plugging directly into the host device as shown.
The power can also be supplied through an external power supply via the
Interface Cable supplied with a power jack.
Product Reference Guide 7
Setup
Connecting the Cable (Corded versions)
A
B
C
D
A. Rubber gasket
B. Cable Holder
C. Cover
D. Connector Holder
1. Slip the cable through the Cover.
2. Push the Rubber Gasket onto the Cable
Holder.
3. Push the Cable Holder and gasket into the handle. Ensure that the “Front” marking on the Cable Holder is facing out, with the arrow pointing towards the front of the scanner.
4. Insert the end of the cable into the socket of the Cable Holder.
5. Push the Cover along the cable towards the reader, and hook it over the yellow
“tooth” on the back of the handle.
6. Insert the cable through the Connector
Holder, and push it up into the Cover.
7. Insert and tighten the screw to affix the cable assembly to the reader handle.
4
5
2
3
FRONT>>
1
6
7
8 PowerScan™ PD9530/PBT9500/PM9500
Configuring the Base Station
Configuring the Base Station
To set up your BC9xx0 cradle you must:
1. Physically install the cradle.
2. Make all system connections.
3. Configure the BC9xx0 cradle.
Mounting the BC9xx0 Cradle
The cradle package contains the following items:
BC9xx0 Base Station (with Desktop Mounting
Bracket installed)
BC9xx0 Quick Reference Guide
(this manual)
1 Metal Mounting plate
1 Wall Mounting Bracket
The cradle can be either mounted on a flat surface for desktop usage or affixed vertically to a wall.
Mounting Brackets
The cradle comes with two different mounting brackets. The appropriate bracket is used depending on whether the cradle will be mounted on a horizontal or vertical surface. When shipped, the cradle has the Desktop Mounting Bracket installed. For vertical installation, the Wall Mounting Bracket must be attached instead.
Figure 1. Mounting Brackets
Ribs
Bosses
Tab
Tab
Tab
Desktop Mounting Bracket
(Horizontal )
Wall Mounting Bracket
(Vertical)
• Desktop mount bracket has ribs to keep the scanner in place when the cradle is horizontal.
• Wall mount bracket contains bosses to keep the scanner in place when the cradle is vertical.
Product Reference Guide 9
Setup
To change the Bracket:
1. Remove the screw holding the Bracket in place. Retain the screw for reuse.
2. Carefully lift off the Bracket.
3. Install the other bracket by first slipping the end tab into place on the base station, then easing the tabs (shown in Figure 1 on page 9 ) into place on the sides.
4. Replace the screw to secure the Bracket to the Base Station.
Figure 2. Changing the Bracket
1 2
3
Permanent Mounting
For either desktop or wall mounting, the cradle can be fastened directly to a flat surface using screws (not included).
When mounting on drywall, the base should be screwed to a wall stud or supporting beam for additional support.
Figure 3. Base Station Bottom
Rubber Feet
Rubber Feet
10
Protective Adhesive
Strips
Mounting
Holes
PowerScan™ PD9530/PBT9500/PM9500
Mounting the BC9xx0 Cradle
Mounting for Portable Use
If portability of the cradle is required, the metal plate must be used. There are two ways this can be done: (1) by first mounting the metal plate on a flat surface so the cradle can be slid off and on, or (2) mounting the metal plate onto the back of the base station and then screwing both to the desired surface.
For additional security on wall mounting, it is strongly recommended that the cradle be secured into place using two auxiliary screws through the mounting holes on the side.
Mounting the Metal Plate
1. Affix the metal plate onto the desired mounting surface using the two center screw holes (see Figure 4 on page 11).
2. Remove the adhesive strips protecting the mounting tabs on the cradle, shown in Figure 3 .
3. Slide the tabs on the back of the cradle onto the metal plate as shown in Figure 4 .
4. After aligning the tabs, push up to lock into place.
Figure 4. Mounting Plate on Wall
Product Reference Guide 11
Setup
Attaching the Metal Plate to Base
Alternatively, the mount can be attached first to the base, then both can be mounted to a wall as described above.
Figure 5. Attaching Mounting Plate to Base
Base with Mount attached
System Connections
Connections should always be made with power off!
CAUTION
The BC9xx0 cradle provides a multi-interface connector and a power supply connector as shown:
12
Power Supply Multi-Interface Connector
PowerScan™ PD9530/PBT9500/PM9500
Mounting the BC9xx0 Cradle
Connecting and Disconnecting the Interface Cable
The BC9xx0 can be connected to a Host by means of a multi-interface cable, which must be simply plugged into the Host connector, visible on the front panel of the cradle.
To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the Host connector on the body of the cradle. Push down on the clip while unplugging the cable. Refer to the following figures:
Connecting/Disconnecting the Cable
Interface Emulation to Host
Power
RS-232
USB*
*The power supply is optional, the cradle can be powered by the USB port. In this case the full charging of an empty battery will take about 10 hours. For intense usage and/or when the system is shut down during the night, the use of an external power supply is recommended.
WEDGE
Product Reference Guide 13
Setup
BC9xx0 Configuration
The BC9xx0 configuration can be performed in three ways: by using the
Datalogic Aladdin ™ software configuration program, by sending configuration strings from the Host PC via the RS-232 or USB-COM interface or by reading configuration bar codes with the PowerScan ™ 9500 reader.
Serial Configuration
By connecting the BC9xx0 to a PC through an RS-232 or USB-COM interface cable it is possible to send configuration strings from the PC to BC9xx0.
Configuration Bar Codes
Link the cradle and the reader using the procedures described in the Power-
Scan ™ PM9500 or PBT9500 Quick Reference. Once the pairing is complete, you can configure the BC9xx0 cradle by reading configuration bar codes in this manual.
To configure the BC9xx0 using the PowerScan ™ face selected.
9500 reader (paired to the cradle with the Bind command), follow the procedure according to the inter-
Interface Selection
Upon completing the physical connection between the reader and its host, proceed to
Table 2 on page 15 to select the interface type the reader is con-
nected to (for example: RS-232, Keyboard Wedge, USB, etc.). Scan the appropriate bar code in that section to configure your system’s correct interface type.
Setting the Interface
Scan the programming bar code from this section which selects the appropriate interface type matching the system the reader will be connected to.
Next, proceed to the corresponding section in this manual (also listed in
) to configure any desired settings and features associated with that interface.
Unlike some programming features and options, interface selections require that you scan only one programming bar code label. DO NOT scan an
ENTER/EXIT bar code prior to scanning an interface selection bar code.
Some interfaces require the scanner to start in the disabled state when powered up. If additional scanner configuration is desired while in this state, pull the trigger and hold it for five seconds. The scanner will change to a state that allows programming with bar codes.
14 PowerScan™ PD9530/PBT9500/PM9500
Interface Selection
Table 2. Available Interfaces
RS-232 FEATURES
RS-232 standard interface
Select RS232-STD
$P,HA12,P(CR)
Select RS232-WN
RS-232 Wincor-Nixdorf
Set RS-232
Interface
Features
$P,HA13,P(CR)
RS-232 for use with OPOS/UPOS/JavaPOS
Select RS-232 OPOS
USB
$P,HA47,P(CR)
FEATURES
USB Com to simulate RS-232 standard interface
Select USB COM-STD a
$P,HA45,P(CR)
USB-OEM
(can be used for OPOS/UPOS/JavaPOS)
Select USB-OEM
$P,HA35,P(CR)
USB Keyboard with standard key encoding
Select USB Keyboard
$P,HA2B,P(CR)
USB Keyboard with alternate key encoding
Select USB Alternate Keyboard
$P,HA2C,P(CR)
USB Keyboard for Apple computers
Select USB-KBD-APPLE a. Download the correct USB Com driver from www.datalogic.com
Set USB-OEM
Interface
Features
Product Reference Guide 15
Setup
KEYBOARD
$P,HA2B,P(CR)
USB Keyboard with alternate key encoding
Select USB Alternate Keyboard
$P,HA2C,P(CR)
USB Keyboard for Apple computers
Select USB-KBD-APPLE
$P,HA29,P(CR)
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 &
95 w/Standard Key Encoding
Select KBD-AT
$P,HA11,P(CR)
Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard
Select KBD-AT-NK
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 &
95 w/Alternate Key
$P,HA26,P(CR)
Select KBD-AT-ALT
$P,HA10,P(CR)
Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard
Select KBD-AT-ALT-NK
FEATURES
Set KEYBOARD
WEDGE
Interface
Features
16 PowerScan™ PD9530/PBT9500/PM9500
Customizing Configuration Settings
Customizing Configuration Settings
Configure Interface Settings
If after scanning the interface bar code from the previous table, your installation requires you to select options to further customize your reader, turn to the appropriate section for your interface type in
"Configuration Parameters" starting on page 21.
Global Interface Features
See " Global Interface Features" on page 23
for settings configurable by all interface types.
Configuring Other Features
If your installation requires different programming than the standard factory default settings, the following sections of this manual allow configuration of non-interface-specific settings you might require. Go to
Using Bar Codes, starting on page 21
for a complete list of available options.
Software Version Transmission
The software version of the device can be transmitted over the RS-232 and
Keyboard interfaces by scanning the following label.
RevA\r
Transmit Software Version
Self Test and Statistics
The internal status of the reader can be accessed in COM interfaces giving the following command string through a Terminal Emulator program:
$S,yX,s[CR] (corded reader only).
Product Reference Guide 17
Setup
Resetting the Product Configuration to Defaults
Restore Custom Defaults
If you aren’t sure what programming options are in your imager, or you’ve changed some options and want to restore the Custom Default Configuration that may have been saved in the scanner, scan the Restore Custom
Default Configuration bar code below. This will restore the custom configuration for the currently active interface.
Custom defaults are based on the interface type. Configure the imager for the correct interface before scanning this label.
$P,HA00,P(CR)
Restore Custom Default Configuration
Restore Factory Configuration
The "Restore Custom Default Configuration" command above is normally enough to restart the machine from a known status (set in the factory or by the customer via configuration file). The machine is set as it arrived to you from the factory or according to the custom configuration file you loaded afterward.
If you want to permanently cancel the setup defined by the configuration
file use "Restore Factory Configuration" on page 321 of this manual.
The programming items listed in the following sections show the factory default settings for each of the menu commands. If no configuration file has been loaded, the above command restores the factory default.
Set Date and Time
1. Scan the Enter/Exit Programming bar code below to set date and time.
18
ENTER/EXIT PROGRAMMING MODE
2. Scan the Set Date bar code + six digits for Year, Month and Day
Set Date
3. Scan Set Time + six digits for
Hours, Minutes and Seconds
Set Time
4. Scan the Enter/Exit Programming bar code to complete.
PowerScan™ PD9530/PBT9500/PM9500
Linking the Reader
Linking the Reader
Link Datalogic RF Devices to Base
For RF devices, before configuring the interface it is necessary to link the handheld with the base.
To link the handheld and the base, press the trigger to wake up the handheld and mount it into the base. If the reader was previously linked to another base, you must first press and hold the button on the base (>5 seconds), then scan the
Unlink
bar code before re-linking to the new base.
Unlink
Linking to a Bluetooth Adapter in Serial Port Profile (Slave) Mode
1. Install any drivers provided with the Bluetooth adapter.
2. Scan the
Enable RF Link to Server
to the host computer.
label below to make the scanner visible
3. Use the host computer’s Bluetooth manager to “Discover new devices” and select "Datalogic Scanner." If you receive an error message, it may be necessary to disable security on the device.
4. Use an RS-232 terminal program to see incoming data on the port designated by the computer's Bluetooth manager.
Enable RF Link to Server
Linking to a Bluetooth Adapter in HID mode
1. Install any drivers provided with the Bluetooth adapter.
2. Scan the
Link to PC in HID
label below..
3. Use the host computer’s Bluetooth manager to “Discover new devices” and select "Datalogic Scanner." If you receive an error message, it may be necessary to disable security on the device.
4. Use a text editor to see incoming data on the port designated by the computer's Bluetooth manager.
Product Reference Guide
Link to PC in HID
The Powerscan BT9500 can be set up to require a PIN code when connecting.
If you want to set up a PIN, or when adding new equipment to a system that uses a custom security PIN, please see
"Bluetooth PIN Code" starting on page 224 for more information.
19
Setup
Power Off
Scan the bar code below to shut off power to the Bluetooth handheld until the next trigger pull . This function only applies to the Bluetooth model.
PowerOff
20 PowerScan™ PD9530/PBT9500/PM9500
Chapter 3
Configuration Using Bar Codes
This and following sections provide programming bar codes to configure your reader by changing the default settings. For details about additional
methods of programming, see " Configuration Methods" on page 6
.
You must first enable your reader to read bar codes in order to use this section. If you have not done this, go to
and complete the appropriate procedure.
Configuration Parameters
Once the reader is set up, you can change the default parameters to meet
your application needs. Refer to "Standard Defaults" starting on page 309 for
initial configuration in order to set the default values and select the interface for your application.
The following configuration parameters are divided into logical groups, making it easy to find the desired function based on its reference group.
Interface Configuration:
•
"RS-232 Only Interface" on page 25
•
"RS-232/USB-Com Interfaces" on page 30
•
"Keyboard Settings" on page 37
Parameters common to all interface applications:
•
"Data Format" on page 49 gives options to control the messages sent to
the Host system by selecting parameters to control the message strings sent to the handheld.
•
"Reading Parameters" on page 63 control various operating modes and
indicators status functioning such as programming for scanning, beeper and LED indicators and other universal settings.
•
"Motion Features" on page 205 provide the ability to configure motion
settings for the handheld.
Wireless-Only Features
• Wireless Configuration:
• Wireless beeper features
• Configuration Updates
• Batch Features
• Direct Radio Autolink
• PBT9500 only features
• PM9500 only features
Product Reference Guide 21
Enter/Exit Programming Mode
• Compatibility with PM8500. programming options for PBT9500 and
PM9500 models only.
• Real Time Clock features
• Display and Keyboard features
Symbology-specific parameters:
•
"1D Symbologies" on page 81 provides configuration of a personalized
mix of 1D codes, code families and their options.
•
"2D Symbologies" on page 173 provides configuration of a personal-
ized mix of 2D codes, code families and their options.
You must first enable your reader to read bar codes in order to use
this section. If you have not done this, go to
and complete the appropriate procedure.
To program features:
1. Scan the ENTER/EXIT PROGRAMMING bar code, available at the top of each programming page, when applicable.
2. Scan the bar code to set the desired programming feature. You may need to cover unused bar codes on the page, and possibly the facing page, to ensure that the reader reads only the bar code you intend to scan.
3. If additional input parameters are needed, go to
and scan the appropriate characters from the keypad.
Additional information about many features can be found in the “References” chapter.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
4. Complete the programming sequence by scanning the ENTER/EXIT
PROGRAMMING bar code to exit Programming Mode.
For more detailed descriptions, programming information and examples for setting selected configuration items, see
References, starting on page 255
.
22 PowerScan™ PD9530/PBT9500/PM9500
$CIFIH01(CR)
Enter/Exit Programming Mode
GLOBAL INTERFACE FEATURES
The following interface features are configurable by all interface types.
Host Commands — Obey/Ignore
This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for:
• service mode
• flash programming mode
• keeping the interface active
• transmission of labels.
$CIFIH00(CR)
DEFAULT
Host Commands = Obey
(Do Not Ignore Host Commands)
Host Commands = Ignore
$CUSSE01(CR)
USB Suspend Mode
This setting enables/disables the ability of USB interfaces to enter suspend mode.
$CUSSE00(CR)
DEFAULT
USB Suspend Mode = Disable
USB Suspend Mode = Enable
Product Reference Guide 23
Enter/Exit Programming Mode
NOTES
24 PowerScan™ PD9530/PBT9500/PM9500
RS-232 ONLY INTERFACE
Use the programming bar codes in this section if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB
interfaces are available in the next section, "RS-232/USB-Com Interfaces" starting on page 30.
Reference
for a listing of standard factory settings.
Product Reference Guide 25
Enter/Exit Programming Mode
Baud Rate
for information on this feature.
$CR2BA00(CR)
Baud Rate = 1200
$CR2BA01(CR)
Baud Rate = 2400
$CR2BA02(CR)
Baud Rate = 4800
$CR2BA03(CR)
Baud Rate = 9600
$CR2BA04(CR)
Baud Rate = 19,200
$CR2BA05(CR)
Baud Rate = 38,400
$CR2BA06(CR)
Baud Rate = 57,600
$CR2BA07(CR)
DEFAULT
Baud Rate = 115,200
26 PowerScan™ PD9530/PBT9500/PM9500
$CR2DA01(CR)
Enter/Exit Programming Mode
Data Bits
This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data.
$CR2DA00(CR)
7 Data Bits
DEFAULT
8 Data Bits
$CR2ST01(CR)
Stop Bits
Set the number of stop bits to match host device requirements. See
page 256 for more information on this feature.
$CR2ST00(CR)
DEFAULT
1 Stop Bit
2 Stop Bits
Product Reference Guide 27
Enter/Exit Programming Mode
Parity
This feature specifies parity required for sending and receiving data. Select
the parity type according to host device requirements. See page 256
for more information.
$CR2PA00(CR)
DEFAULT
Parity = None
$CR2PA01(CR)
Parity = Even
$CR2PA02(CR)
Parity = Odd
28 PowerScan™ PD9530/PBT9500/PM9500
$CR2HC01(CR)
Enter/Exit Programming Mode
Handshaking Control
for more information about this feature.
$CR2HC00(CR)
DEFAULT
Handshaking Control = RTS
Handshaking Control = RTS/CTS
$CR2HC02(CR)
Handshaking Control = RTS/XON/XOFF
$CR2HC03(CR)
Handshaking Control = RTS On/CTS
$CR2HC04(CR)
Handshaking Control = RTS/CTS Scan Control
Product Reference Guide 29
RS-232/USB-COM INTERFACES
B EEP O N ASCII BEL on page 31
I NDICATE T RANSMISSION F AILURE
The programming bar codes in this chapter allow modifications to the stan-
dard RS-232 and USB-Com interfaces. Reference Appendix C, Standard
for a listing of standard factory settings.
Product Reference Guide 30
Enter/Exit Programming Mode
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
for more information.
$CR2IC00(CR)
$CR2IC
Select Intercharacter Delay Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Intercharacter Delay = No Delay
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 00 = No Intercharacter Delay
Beep On ASCII BEL
When this parameter is enabled, the reader issues a beep when a <BEL> character is detected on the RS-232 serial line. <BEL> is issued to gain a user's attention to an illegal entry or other important event.
$CR2BB00(CR)
Beep On ASCII BEL = Disable
DEFAULT
$CR2BB01(CR)
Product Reference Guide
Beep On ASCII BEL = Enable
31
Enter/Exit Programming Mode
Beep On Not on File
This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.
$CBPNF00(CR)
Beep On Not On File = Disable
$CBPNF01(CR)
DEFAULT
Beep On Not On File = Enable
ACK NAK Options
This enables/disables the ability of the reader to support the RS-232 ACK/
NAK protocol.
for more information.
$CR2AE00(CR)
DEFAULT
ACK/NAK Protocol = Disable ACK/NAK
$CR2AE01(CR)
ACK/NAK Protocol = Enable for label transmission
$CR2AE02(CR)
ACK/NAK Protocol = Enable for host-command acknowledge
$CR2AE03(CR)
ACK/NAK Protocol = Enable for label transmission and host-command acknowledge
32 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
ACK Character
This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected.
for more information.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with
normal operation of these characters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
$CR2AC
Select ACK Character Setting
DEFAULT 0x06 ‘ACK’ Character
$CR2NA
NAK Character
This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with
normal operation of these characters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
for more information.
Select NAK Character Setting
DEFAULT 0x15 ‘NAK’ Character
Product Reference Guide 33
Enter/Exit Programming Mode
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.
for more information on setting this feature.
$CR2AT
Select ACK NAK Timeout Value Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 01 ACK NAK Timeout value is 200ms
$CR2AR
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. See
page 261 for more information.
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 003 = 3 Retries
34 PowerScan™ PD9530/PBT9500/PM9500
$CR2EH01(CR)
Enter/Exit Programming Mode
ACK NAK Error Handling
This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
$CR2EH00(CR)
DEFAULT
ACK NAK Error Handling = Ignore Errors Detected
ACK NAK Error Handling = Process Error as Valid ACK Character
$CR2EH02(CR)
ACK NAK Error Handling = Process Error as
Valid NAK Character
Indicate Transmission Failure
This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode .
$CR2TF00(CR)
Indicate Transmission Failure = Disable Indication
$CR2TF01(CR)
Indicate Transmission Failure = Enable Indication
DEFAULT
Product Reference Guide 35
Enter/Exit Programming Mode
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option
for more information on setting this feature.
$CR2DC
Select Disable Character Setting
DEFAULT 0x44 = Disable Character is ‘D’
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the
in “References” for more information on setting this feature.
$CR2EC
Select Enable Character Setting
DEFAULT 0x45 = Enable Character is ‘E’
36 PowerScan™ PD9530/PBT9500/PM9500
KEYBOARD SETTINGS
USB K EYBOARD N UMERIC K EYPAD
Use the programming bar codes in this chapter to select options for USB
Keyboard and Wedge Interfaces. Reference Appendix C, Standard Defaults
for a listing of standard factory settings.
Information about control character emulation which applies to keyboard interfaces is listed in
.
Product Reference Guide 37
Enter/Exit Programming Mode
Country Mode
This feature specifies the country/language supported by the keyboard.
Several languages are supported:
$CKBCO00(CR)
DEFAULT
Country Mode = U.S.
$CKBCO01(CR)
Country Mode = Belgium
$CKBCO02(CR)
$CKBCO11(CR)
Country Mode = Britain
Supports only the interfaces listed in the
Country Mode feature description.
Country Mode = Croatia
Supports only the interfaces listed in the Country
Mode feature description.
$CKBCO0E(CR)
Country Mode = Czech Republic
$CKBCO03(CR)
Supports only the interfaces listed in the Country Mode feature description.
Country Mode = Denmark
$CKBCO04(CR)
Country Mode = France
38 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Country Mode (continued)
Supports only the interfaces listed in the Country
Mode feature description.
$CKBCO13(CR)
Country Mode = French Canadian
$CKBCO05(CR)
Country Mode = Germany
Supports only the interfaces listed in the Country
Mode feature description.
$CKBCO0D(CR)
Country Mode = Hungary
$CKBCO06(CR)
Country Mode = Italy
Supports only the interfaces listed in the Country
Mode feature description.
$CKBCO0C(CR)
Country Mode = Japanese 106-key
$CKBCO14(CR)
Supports only the interfaces listed in the Country Mode feature description.
Country Mode = Lithuanian
$CKBCO07(CR)
Country Mode = Norway
Product Reference Guide 39
Enter/Exit Programming Mode
Country Mode (continued)
$CKBCO12(CR)
Supports only the interfaces listed in the Country Mode feature description.
Country Mode = Poland
Supports only the interfaces listed in the Country
Mode feature description.
$CKBCO08(CR)
Country Mode = Portugal
$CKBCO10(CR)
Supports only the interfaces listed in the Country Mode feature description.
Country Mode = Romania
Supports only the interfaces listed in the Country
Mode feature description.
$CKBCO0F(CR)
Country Mode = Slovakia
$CKBCO09(CR)
Country Mode = Spain
$KBCO0A(CR)
Country Mode = Sweden
$CKBCO0B(CR)
Country Mode = Switzerland
Supports only the interfaces listed in the Country Mode feature description.
40 PowerScan™ PD9530/PBT9500/PM9500
$CKBSC01(CR)
Enter/Exit Programming Mode
Send Control Characters
This feature specifies how the reader transmits ASCII control characters to
the host. Reference Appendix E, Scancode Tables
for more information about control characters.
Options are as follows:
Control Character 00 :
Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Control Character 01 :
Characters from 00 to 0x1F are sent as control character Ctrl+Shift, special keys are located from 0x80 to 0xA1.
Control Character 02 :
Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table (see
Windows Codepage 1252" on page 333).
$CKBSC00(CR)
DEFAULT
Wedge Send Control Characters = 00
Wedge Send Control Characters = 01
$CKBSC02(CR)
Wedge Send Control Characters = 02
Product Reference Guide 41
Enter/Exit Programming Mode
$CKBQI
Wedge Quiet Interval
Specifies amount of time to look for keyboard activity before scanner breaks keyboard connection in order to transmit data to host. The selectable range for this setting is 00 to 990 milliseconds (00-0x63 by 01) in increments of ten milliseconds.
in “References” for detailed information and examples for setting this feature.
Set Wedge Quiet Interval
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from
the Alphanumeric characters in
representing your desired character(s).
End by scanning the ENTER/EXIT bar code again.
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 0A = Quiet Interval is
100 milliseconds
$CKBID
Intercode Delay
Specifies the delay between labels transmitted to the host for this interface.
The selectable range for this feature is from 0 to 99 seconds.
in “References” for detailed information and examples for setting this feature.
Set Intercode Delay
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from
the Alphanumeric characters in
representing your desired character(s).
End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 00 = No Wedge Intercode Delay
42 PowerScan™ PD9530/PBT9500/PM9500
$CKBCL01(CR)
Enter/Exit Programming Mode
Caps Lock State
This option specifies the format in which the reader sends character data.
This does not apply when an alternate key encoding keyboard is selected.
$CKBCL00(CR)
DEFAULT
Caps Lock State = Caps Lock OFF
Caps Lock State = Caps Lock ON
$CKBCL02(CR)
Caps Lock State = AUTO Caps Lock Enable
$CKBNL01(CR)
Numlock
This option specifies the setting of the NUMLOCK key in the Keyboard
Wedge interface.
$CKBNL00(CR)
DEFAULT
Numlock = NUMLOCK key unchanged
Numlock = Numlock key toggled
Product Reference Guide 43
Enter/Exit Programming Mode
USB Keyboard Speed
This option specifies the USB poll rate for a USB keyboard.
This feature applies ONLY to the USB Keyboard interface.
DEFAULT
$CKBSP02(CR)
USB Keyboard Speed = 2ms
$CKBSP01(CR)
USB Keyboard Speed = 1ms
$CKBSP03(CR)
USB Keyboard Speed = 3ms
$CKBSP04(CR)
USB Keyboard Speed = 4ms
$CKBSP05(CR)
USB Keyboard Speed = 5ms
$CKBSP06(CR)
USB Keyboard Speed = 6ms
44 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
USB Keyboard Speed (continued)
$CKBSP07(CR)
USB Keyboard Speed = 7ms
$CKBSP08(CR)
USB Keyboard Speed = 8ms
$CKBSP09(CR)
USB Keyboard Speed = 9ms
$CKBSP0A(CR)
USB Keyboard Speed = 10ms
$CKBKP01(CR)
USB Keyboard Numeric Keypad
This option Controls whether numeric characters will be sent using standard keys or the numeric keypad.
$CKBKP00(CR)
DEFAULT
Standard Keys
Numeric Keypad
Product Reference Guide 45
Enter/Exit Programming Mode
NOTES
46 PowerScan™ PD9530/PBT9500/PM9500
USB-OEM INTERFACE
Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the USB-OEM interface. Other USB interfaces are included in the appropriate chapter for their host type.
Reference
for a listing of standard factory settings.
Product Reference Guide 47
Enter/Exit Programming Mode
USB-OEM Device Usage
The USB-OEM protocol allows for the reader to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate.
Options are:
• Table Top Scanner
• Handheld Scanner
It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.
$CIBUT01(CR)
USB-OEM Device Usage = Handheld Scanner
$CIBUT00(CR)
USB-OEM Device Usage = Table Top Scanner
DEFAULT
Interface Options
This feature provides for an interface-specific control mechanism.
$CIFO101(CR)
$CIFO102(CR)
Ignore Scanner Configuration Host Commands
Obey Scanner Configuration Host Commands
DEFAULT
48 PowerScan™ PD9530/PBT9500/PM9500
DATA FORMAT
G LOBAL P REFIX /S UFFIX (H EADER /T ERMINA -
Label ID Symbology Selection − 1D Symbol-
It is not recommended to use these features with IBM interfaces.
CAUTION
The features in this chapter can be used to build specific user-defined data into a message string. See “References” starting on
detailed instructions on setting these features.
Product Reference Guide 49
Enter/Exit Programming ModeGlobal Prefix/Suffix (Header/Terminator)
Global Prefix/Suffix (Header/Terminator)
This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the bar code data, also called a header) and/or as a suffix (in a position following the bar code data, also called a terminator). See
page 270 for more detailed instructions on setting this feature.
To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE bar code above to place the unit in Programming Mode, then the “Set Global
Prefix” or “Set Global Suffix,” bar code followed by the digits (in hex) from the Alphanumeric characters in
Appendix D, Keypad representing your
desired character(s). If less than the expected string of 20 characters are selected, scan the ENTER/EXIT bar code to terminate the string. Exit programming mode by scanning the ENTER/EXIT bar code again.
$CLFPR
Set Global Prefix
$CLFSU
Set Global Suffix
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT No Global Prefix
Global Suffix = 0x0D (CR)
CANCEL
50 PowerScan™ PD9530/PBT9500/PM9500
Global AIM ID
Global AIM ID
Enter/Exit Programming Mode
This feature enables/disables addition of AIM IDs for all symbology types.
AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. See
Table 3 on page 51 for a listing of AIM IDs.
AIM label identifiers consist of three characters as follows:
• A close brace character (ASCII ‘]’), followed by...
• A code character (see some samples in the table below), followed by...
• A modifier character (the modifier character is symbol dependent).
$CAIEN00(CR)
DEFAULT
Global AIM ID = Disable
$CAIEN01(CR)
Global AIM ID = Enable
Table 3. AIM IDs
Tag Name
ABC CODABAR
ANKER PLESSEY
AZTEC
CHINA SENSIBLE CODE
CODABAR
CODE11
CODE128
CODE32
CODE39
CODE39 CIP
CODE39 DANISH PPT
A
X
X
F
H
C
A
AIM ID code character
X
N z
X
41
58
58
46
48
43
41
AIM ID code
ASCII value
58
4E
7A
58
Product Reference Guide 51
Enter/Exit Programming ModeGlobal AIM ID
CODE39 LAPOSTE
CODE39 PZN
CODE93
DATABAR 14
DATABAR 14 COMPOSITE
DATABAR EXPANDED
DATABAR EXPANDED
COMPOSITE
DATABAR LIMITED
DATABAR LIMITED COMPOSITE
DATA MATRIX
EAN128
EAN128 COMPOSITE
EAN13
EAN13 P2
EAN13 P5
EAN13 COMPOSITE
EAN8
EAN8 P2
EAN8 P5
EAN8 COMPOSITE
FOLLET 2OF5
I2OF5
IATA INDUSTRIAL 2OF5
INDUSTRIAL 2OF5
ISBN
ISBT128 CONCAT
ISSN
MAXICODE
MICRO QR
G e
X
X e e
E
E
E
X
E
E
E
E d
C
C
E e e e
X
X
U
Q
I
X
X
X
52
45
45
45
58
45
45
45
45
64
43
43
45
65
65
65
58
58
55
51
49
58
58
58
58
58
47
65
65
65
PowerScan™ PD9530/PBT9500/PM9500
Global AIM ID
MICRO PDF
MSI
PDF417
PLESSEY
POSTAL AUSTRALIAN
POSTAL IMB
POSTAL JAPANESE
POSTAL KIX
POSTAL PLANET
POSTAL PORTUGAL
POSTAL POSTNET BB
POSTAL ROYAL MAIL
POSTAL SWEDISH
POSTNET
QR CODE
S25
TRIOPTIC
UPCA
UPCA P2
UPCA P5
UPCA COMPOSITE
UPCE
UPCE P2
UPCE P5
UPCE COMPOSITE
Q
S
X
E
X
X
X
X
X
X
X
X
L
P
L
M
X
X
E
E
E
E
E
E
E
Enter/Exit Programming Mode
51
53
58
45
58
58
58
58
58
58
58
58
4C
4D
4C
50
58
58
45
45
45
45
45
45
45
Product Reference Guide 53
Enter/Exit Programming ModeGlobal AIM ID
Set AIM ID Individually for GS1-128
This feature configures a Label ID individually for the GS1-128 symbology and the programming for this works the same way as Label ID. See
Set Individually Per Symbology, starting on page 275
for detailed instructions on setting this feature.
$CU8AI00(CR)
Set AIM ID Individually for GS1-128 = Disable
$CU8AI01(CR)
DEFAULT
Set AIM ID Individually for GS1-128 = Enable
54 PowerScan™ PD9530/PBT9500/PM9500
Label ID
Label ID
Enter/Exit Programming Mode
A Label ID is a customizable code of up to three ASCII characters (convert to
Hex using the ASCII Chart on the inside back cover of this manual), used to identify a bar code symbology type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs or
individually per symbology (see "Individually Set Label ID" on page 56). If
you wish to program the reader to always include an industry standard label identifier for ALL symbology types, see the previous feature
See Label ID, starting on page 272 of “References” for more information on
setting this feature.
Label ID: Pre-Loaded Sets
The reader supports two pre-loaded sets of Label IDs. See
Label ID: Preloaded Sets, starting on page 272 for details on the USA set and EU set.
CAUTION
When changing from one Label ID set to another, all other reader configuration settings, including the host interface type, will be erased and set to the standard factory defaults. Any custom configuration or custom defaults will be lost.
$AE(CR)
$Ae(CR)
Label ID Pre-loaded Set = USA Set
DEFAULT
Label ID Pre-loaded Set = EU Set
Product Reference Guide 55
Enter/Exit Programming ModeLabel ID
Individually Set Label ID
This feature configures a Label ID individually for a single symbology. To set, first define whether you want it as a prefix or suffix by scanning a label below. Then turn to
Label ID Symbology Selection − 1D
Symbologies, starting on page 57
to select the symbology you want to set, followed by up to 3 characters from the ASCII Chart at the back of this man-
ual. See " Label ID: Set Individually Per Symbology" on page 275 for detailed
instructions on setting this feature.
Label ID Control
This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbology type.
$CIDCO00(CR)
DEFAULT
Label ID Transmission = Disable
$CIDCO01(CR)
Label ID Transmission = Enable as Prefix
$CIDCO02(CR)
Label ID Transmission = Enable as Suffix
56 PowerScan™ PD9530/PBT9500/PM9500
Label ID
$CACID
Enter/Exit Programming Mode
Label ID Symbology Selection − 1D Symbologies
This option selects the symbology for which a Label ID is to be configured.
on page 55 or page 275 in “References” for more detailed
instructions.
If less than the expected string of 3 characters are selected, scan the
ENTER/EXIT bar code twice to accept the selection and exit Programming Mode.
$CP3ID
Set ABC Codabar Label ID Character(s)
$CALID
Set Code 32 Pharmacode Label ID Character(s)
$CC9ID
Set Anker Plessey Label ID Character(s)
$CPAID
Set Australian Postal Code Label ID Character(s)
$CCBID
Set Codabar Label ID Character(s)
$CC1ID
Set Code 93 Label ID Character(s)
$CI8ID
Set Concatenated ISBT 128 Label ID Character(s)
$CDPID
Set Danish PPT Label ID Character(s)
$C3BID
Set Code 11 Label ID Character(s)
$CC8ID
Set Code 128 Label ID Character(s)
$CC3ID
Set EAN 13 Label ID Character(s)
$C3MID
Set EAN 13 Composite Label ID Character(s)
$C32ID
Set Code 39 Label ID Character(s)
$CCCID
Set Code 39 CIP Label ID Character(s)
Product Reference Guide
Set EAN 13 P2 Label ID Character(s)
$C35ID
Set EAN 13 P5 Label ID Character(s)
57
Enter/Exit Programming ModeLabel ID
Label ID Symbology Selection − 1D Symbologies (continued)
$C8BID $CXCID
$C8MID
Set EAN 8 Label ID Character(s) Set GS1 DataBar Expanded Composite
Label ID Character(s)
$CU8ID
Set EAN 8 Composite Label ID Character(s)
$C82ID
Set EAN 8 P2 Label ID Character(s)
$C85ID
Set EAN 8 P5 Label ID Character(s)
$CF2ID
Set Follett 2 of 5 Label ID Character(s)
$C4BID
Set GS1 DataBar 14 Label ID Character(s)
$C4CID
Set GS1 DataBar 14 Composite Label ID Character(s)
$CXBID
Set GS1-128 Label ID Character(s)
$CUMID
Set GS1-128 Composite Label ID Character(s)
$CLBID
Set GSI DataBar Limited Label ID Character(s)
$CLCID
GSI DataBar Limited Composite Label ID Character(s)
$CG2ID
Set GTIN 2 Label ID Character(s)
$CG5ID
$CGBID
Set GTIN 5 Label ID Character(s)
Set GS1 DataBar Expanded Label ID Character(s)
$CIAID
Set IATA Industrial 2 of 5 Label ID Character(s)
$CLPID
Set GTIN 8 Label ID Character(s)
Set LaPoste Code 39 Label ID Character(s)
58 PowerScan™ PD9530/PBT9500/PM9500
Label ID Enter/Exit Programming Mode
Label ID Symbology Selection − 1D Symbologies (continued)
$CPMID $CMSID
Set IMB Postal Code Label ID Character(s)
$CU2ID $CPPID
Set MSI Label ID Character(s)
Set Industrial 2 of 5 Label ID Character(s)
$CI2ID
Set Interleaved 2 of 5 Label ID Character(s)
$CISID
Set Planet Postal Code Label ID Character(s)
$CPLID
Set Plessey Label ID Character(s)
$CPGID
Set Portugal Postal Code Label ID Character(s)
$CPNID
Set Postnet Label ID Character(s)
$CPKID
$CINID
Set ISBN Label ID Character(s)
$CPJID
Set ISSN Label ID Character(s)
Set Japan Postal Code Label ID Character(s)
$CPZID
Set PZN Code Label ID Character(s)
$CPRID
Set Royal Postal Code Label ID Character(s)
$CS2ID
Set Standard 2 of 5 Label ID Character(s)
Set Kix Postal Code Label ID Character(s)
$CPBID
Set Postnet BB Label ID Character(s)
$CAMID
Set UPC-A Composite Label ID Character(s)
$CA2ID
Set UPC-A P2 Label ID Character(s)
Product Reference Guide 59
Enter/Exit Programming ModeLabel ID
Label ID Symbology Selection − 1D Symbologies (continued)
$CPSID $CA5ID
Set Swedish Postal Code Label ID Character(s)
$CCTID
Set Trioptic Code Label ID Character(s)
$CABID
Set UPC-A Label ID Character(s)
Set UPC-A P5 Label ID Character(s)
$CEBID
$CE5ID
Set UPC-E Label ID Character(s)
Set UPC-E P5 Label ID Character(s)
Label ID Symbology Selection − 2D Symbologies
$CAZID $CMXID
$CCSID
Set Aztec Label ID Character(s) Set Maxicode Label ID Character(s)
$CP4ID
Set China Sensible Label ID Character(s)
$CCFID
Set Codablock F Label ID Character(s)
$CDMID
Set Data Matrix Label ID Character(s)
$CMQID
Set Micro QR Label ID Character(s)
Set PDF 417 Label ID Character(s)
$CMIID
Set Micro PDF 417 Label ID Character(s)
$CQRID
Set QR Code Label ID Character(s)
60 PowerScan™ PD9530/PBT9500/PM9500
$CLFCA01(CR)
Label ID
Advanced Formatting: User Label Edit
Advanced formatting is available to create user label edit scripts. See the
Datalogic Aladdin configuration application or contact Technical Support.
Case Conversion
This feature allows conversion of the case of all alphabetic characters to upper or lower case.
Case conversion affects ONLY scanned bar code data, and does not affect
Label ID, Prefix, Suffix, or other appended data.
$CLFCA00(CR)
DEFAULT
Case Conversion = Disable (no case conversion)
Case Conversion = Convert to upper case
$CLFCA02(CR)
Case Conversion = Convert to lower case
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are
4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is
FF, then no conversion is done.
If less than the expected string of 16 characters are selected, scan the
ENTER/EXIT bar code twice to accept the selections and exit Programming
Mode.
$CLFCH
Configure Character Conversion
DEFAULT 0xFFFFFFFFFFFFFFFF
(No character conversion)
Product Reference Guide 61
NOTES
62 PowerScan™ PD9530/PBT9500/PM9500
READING PARAMETERS
G OOD R EAD : W HEN TO I NDICATE
P ARTIAL L ABEL R EADING C ONTROL
M ULTIPLE L ABELS O RDERING BY C ODE
M ULTIPLE L ABELS O RDERING BY C ODE
S TAND M ODE I LLUMINATION O FF T IME on page 73
Product Reference Guide 63
Enter/Exit Programming Mode
Double Read Timeout
Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label read.
$CSNDR0A(CR)
Double Read Timeout = 0.1 Second
$CSNDR14(CR)
Double Read Timeout = 0.2 Second
$CSNDR1E(CR)
Double Read Timeout = 0.3 Second
$CSNDR28(CR)
Double Read Timeout = 0.4 Second
$CSNDR32(CR)
Double Read Timeout = 0.5 Second
$CSNDR3C(CR)
DEFAULT
Double Read Timeout = 0.6 Second
$CSNDR46(CR)
Double Read Timeout = 0.7 Second
64 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Double Read Timeout (continued)
$CSNDR50(CR)
Double Read Timeout = 0.8 Second
$CSNDR5A(CR)
Double Read Timeout = 0.9 Second
$CSNDR64(CR)
Double Read Timeout = 1 Second
Product Reference Guide 65
Enter/Exit Programming Mode
LED AND BEEPER INDICATORS
Power On Alert
Disables or enables the indication (from the Beeper) that the reader is receiving power.
$CBPPU00(CR)
Power On Alert = Disable (No Audible Indication)
$CBPPU01(CR)
Power On Alert = Power-up Beep
DEFAULT
Good Read: When to Indicate
This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a bar code.
$CBPIN00(CR)
DEFAULT
Indicate Good Read = After Decode
$CBPIN01(CR)
Indicate Good Read = After Transmit
$CBPIN02(CR)
Indicate Good Read =
After CTS goes inactive then active
66 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Good Read Beep Type
Specifies whether the good read beep has a mono or bitonal beep sound.
$CBPTY00(CR)
DEFAULT
Good Read Beep Type = Mono
$CBPTY01(CR)
Good Read Beep Type = Bitonal
Good Read Beep Frequency
Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/ tone.)
$CBPFR00(CR)
Good Read Beep Frequency = Low
$CBPFR01(CR)
Good Read Beep Frequency = Medium
DEFAULT
$CBPFR02(CR)
Good Read Beep Frequency = High
Product Reference Guide 67
Enter/Exit Programming Mode
Good Read Beep Length
$CBPLE08(CR)
Good Read Beep Length = 80 msec
$CBPLE06(CR)
Good Read Beep Length = 60 msec
DEFAULT
$CBPLE0A(CR)
Good Read Beep Length = 100 msec
$CBPLE0C(CR)
Good Read Beep Length = 120 msec
$CBPLE0E(CR)
Good Read Beep Length = 140 msec
$CBPLE10(CR)
Good Read Beep Length = 160 msec
$CBPLE12(CR)
Good Read Beep Length = 180 msec
$CBPLE14(CR)
Good Read Beep Length = 200 msec
68 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Good Read Beep Volume
Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
$CBPVO00CR)
Good Read Beep Volume = Beeper Off
$CBPVO01CR)
Good Read Beep Volume = Low
$CBPVO02CR)
Good Read Beep Volume = Medium
$CBPVO03CR)
Good Read Beep Volume = High
DEFAULT
Product Reference Guide 69
Enter/Exit Programming Mode
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in
100ms increments. A setting of 00 keeps the LED on until the next trigger pull.
in “References” for detailed instructions and examples for setting this feature.
$CLAGL00(CR)
$CLAGL
Select Good Read LED Duration Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Good Read LED Duration Setting =
Keep LED on until next trigger pull
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT
003 = Good Read LED stays on for 300 ms.
Indicators are dimmed during sleep.
70 PowerScan™ PD9530/PBT9500/PM9500
$CSNRM00(CR)
Enter/Exit Programming Mode
SCANNING FEATURES
Scan Mode
Selects the reader’s scan operating mode. See page 279
in “References” for descriptions.
DEFAULT
Scan Mode = Trigger Single
$CSN-
Scan Mode = Trigger Hold Multiple
$CSNRM02(CR)
Scan Mode = Trigger Pulse Multiple
$CSN-
Scan Mode = Flashing
$CSN-
Scan Mode = Always On
$CSN-
Scan Mode = Stand Mode
Product Reference Guide 71
Enter/Exit Programming Mode
Stand Mode Indication
This operation is useful for indicating when the reader is in Stand Mode. If enabled, the blue indicator will blink when Stand Mode scanning is active.
$CSMFL00(CR)
DEFAULT
Stand Mode Indication = Disable
$CSMFL01(CR)
Stand Mode Indication = Enable
Pick Mode
Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern. This allows the reader to accurately target labels when they are placed close together, such as on a pick sheet.
This feature is not compatible with Multiple Labels Reading in a Volume.
$CSNPM00(CR)
DEFAULT
Pick Mode = Disable
$CSNPM01(CR)
Pick Mode = Enable
72 PowerScan™ PD9530/PBT9500/PM9500
$CSMSE01(CR)
Enter/Exit Programming Mode
Stand Mode Sensitivity
Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high.
$CSMSE00(CR)
Stand Mode Sensitivity = Low
DEFAULT
Stand Mode Sensitivity = Medium
$CSMSE02(CR)
Stand Mode Sensitivity = High
$CSNTM
Stand Mode Illumination Off Time
Specifies the amount of time reader illumination stays off after pulling the trigger when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds). See
for a description of this feature.
Select Stand Mode Time Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
DEFAULT
04 = 2 Seconds
Product Reference Guide 73
Enter/Exit Programming Mode
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. See
in “References” for further description of this feature.
$CSNET03(CR)
Scanning Active Time = 3 seconds
$CSNET05(CR)
Scanning Active Time = 5 seconds
DEFAULT
$CSNET08(CR)
Scanning Active Time = 8 seconds
$CSMIL01(CR)
Stand Illumination Control
Controls the illumination status while the reading mode is stand mode and the reader is attempting to detect objects.
$CSMIL00(CR)
DEFAULT
Stand Illumination Control = OFF
Stand Illumination Control = ON
$CSMIL02(CR)
Stand Illumination Control = Dim
74 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
$CSNFN
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments. See page 283
in “References” for detailed information on setting this feature.
Select Flash ON Time Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~ Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT
10 = Flash is ON for 1 Second
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash
Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 sec-
onds), in 100 millisecond increments. See page 284 in “References” for
detailed information on setting this feature.
$CSNFF
Select Flash OFF Time Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 06 = Flash is OFF for 600ms
Product Reference Guide 75
Enter/Exit Programming Mode
Aiming Pointer
Enables/disables the aiming pointer for all symbologies.
$CTAAP00(CR)
$CTAAP01(CR)
Aiming Pointer = Enable
Aiming Pointer = Disable
DEFAULT
Aiming Duration Timer
Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger single mode.The range for this setting is from 1 to
255 seconds in 1-second increments. See
page 282 in “References” for a
description of this feature.
LSTM00
DEFAULT
LSTM
Set Aiming Duration Timer
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Aiming Off After Decoding
To configure, scan the ENTER/EXIT PROGRAMMING
MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric charac-
desired character(s). End by scanning the ENTER/
EXIT bar code.
~
CANCEL
76 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Green Spot Duration
Specifies the duration of the good read pointer beam after a good read.
$CLSSP00(CR)
Green Spot Duration = Disable (Green Spot is Off)
$CLSSP01(CR)
Green Spot Duration = Short (300 msec)
DEFAULT
$CLSSP02(CR)
Green Spot Duration = Medium (500 msec)
$CLSSP03(CR)
Green Spot Duration = Long (800 msec)
IPPL00
Partial Label Reading Control
Enable/Disable the option to ignore partial labels to be read within the boundary of the field of view.
Partial Label Reading Control = Disable
IPPL01
Partial Label Reading Control = Enable
Product Reference Guide 77
Enter/Exit Programming Mode
Decode Negative Image
Enable/Disable the ability to decode a negative image for all symbologies.
When this feature is enabled, you will be unable to read normally-printed labels or programming labels in this manual. Scan the “Disable” bar code below to return the scanner to its default for this feature.
The reader can also be set to decode both positive and negative codes for
certain 2D codes. See " 2D Normal/Inverse Symbol Control" on page 175
for information on this feature.
For additional options, see the Aladdin configuration application.
Unlike some programming features and options, Decode Negative
Image selections require that you scan only one programming bar code label. DO NOT scan an ENTER/EXIT bar code prior to scanning a
Decode Negative Image bar code.
CAUTION
When this feature is enabled, you will be unable to read other programming labels in this manual.
$P,CIPVR00,P(C
R)
DEFAULT
Decode Negative Image = Disable
$P,CIPVR01,P(CR)
Decode Negative Image = Enable
Image Capture
Image capature is supported by RS-232 and USB-COM interfaces only. For information and a list of options for Image Capture, use the Datalogic Aladdin configuration application, available for free download from the Datalogic
Scanning website.
78 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
MULTIPLE LABEL READING
In standard (default) mode, when the reader’s aiming system is activated (by a trigger pull, motion or other method depending on the mode), it then acquires and processes each image in the area in front of it (the Volume). In this case, the scanner stops processing the image once it decodes a label. If several labels are present in the volume, only the first label encountered is decoded and sent.
When Multiple Reading Mode is enabled, the scanner keeps on processing the image until all the labels present are decoded. The reader then sorts the data from all the bar codes (if configured to do so) before transmitting it.
Multiple Labels per Frame
Specifies the ability of the reader to decode and transmit a set of code labels in a specific volume and in a single frame of time. When in Multiple Labels per Frame the reader beeps and turns on the good read LED indication for each code read in a frame.
When Multiple Labels Mode is enabled, ISBT pairing, ABC Codabar pairing, and composites are not allowed.
$CSNML00(CR)
DEFAULT
Multiple Labels per Frame = Disable
$CSNML01(CR)
Multiple Labels per Frame = Enable
Product Reference Guide 79
Enter/Exit Programming Mode
$CSNMS
Multiple Labels Ordering by Code Symbology
This feature allows you to specify the order multiple labels are transmitted by symbology type, when Multiple Labels per Frame is enabled. See
page 285 in “References” for detailed information on setting this feature.
Select Symbologies for Multiple Labels Ordering
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits From the alphanumeric characters In Appendix d, keypad representing your desired Character(s). end by scanning the enter/exit bar code again.
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT
000000000000 = Random order
Multiple Labels Ordering by Code Length
Specifies the transmission ordering by code length, when Multiple Labels per Frame is enabled.
$CSNMT00(CR)
DEFAULT
$CSNMT01(CR)
Multiple Labels Ordering = Disable
$CSNMT02(CR)
Transmit Increasing Length Order Transmit Decreasing Length Order
80 PowerScan™ PD9530/PBT9500/PM9500
1D SYMBOLOGIES
The reader supports the following 1D symbologies (bar code types). See
Symbologies" starting on page 173
for 2D bar codes. Symbology-dependent options are included in each chapter.
Disable All Symbologies, page 82
UPC/EAN Global Settings, page 95
Interleaved 2 of 5 (I 2 of 5), page 123
Interleaved 2 of 5 CIP HR, page 128
Code 32 (Ital Pharmaceutical Code), page 109 GS1 DataBar™ Omnidirectional, page 151
Code 39 CIP (French Pharmaceutical), page 111 GS1 DataBar™ Expanded, page 152
GS1 DataBar™ Limited, page 157
Default settings are indicated at each feature/option with a green arrow.
Also reference
for a listing of the most widely used set of standard factory settings.
To set most features:
1. Scan the ENTER/EXIT PROGRAMMING bar code at the top of applicable programming pages.
2. Scan the correct bar code to set the desired programming feature or parameter. You may need to cover unused bar codes on the page, and possibly the facing page, to ensure that the reader reads only the bar code you intend to scan.
3. If additional input parameters are needed, go to
and scan the appropriate characters from the keypad.
Additional information about many features can be found in the “References” chapter.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
4. Complete the programming sequence by scanning the ENTER/EXIT
PROGRAMMING bar code to exit Programming Mode.
Product Reference Guide 81
Enter/Exit Programming Mode
DISABLE ALL SYMBOLOGIES
Use this feature to disable all symbologies.
1. Scan the ENTER/EXIT PROGRAMMING Mode bar code.
2. Scan the Disable All Symbologies bar code.
3. Complete the programming sequence by scanning the ENTER/EXIT
PROGRAMMING bar code.
$AD(CR)
Disable All Symbologies
This does not disable the reading of programming labels.
82 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
CODE EAN/UPC
Coupon Control
This feature is used to control the reader’s method of processing coupon labels.
$CCPLC00(CR)
$CCPLC01(CR)
Coupon Control = Enable only UPCA coupon decoding
Coupon Control = Allow all coupon bar codes to be decoded
DEFAULT
$CCPLC02(CR)
Coupon Control = Enable only GS1 DataBar™
coupon decoding
Product Reference Guide 83
Enter/Exit Programming Mode
UPC-A
The following options apply to the UPC-A symbology.
UPC-A Enable/Disable
When disabled, the reader will not read UPC-A bar codes.
$CABEN00(CR)
$CABEN01(CR)
UPC-A = Disable
DEFAULT
UPC-A = Enable
UPC-A Check Character Transmission
Enable this option to transmit the check character along with UPC-A bar code data.
$CABCT00(CR)
$CABCT01(CR)
UPC-A Check Character Transmission = Send
UPC-A Check Character Transmission = Don’t Send
DEFAULT
84 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Expand UPC-A to EAN-13
Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
DEFAULT
$CAB3B00(CR)
UPC-A to EAN-13 = Don’t Expand
$CAB3B01(CR)
UPC-A to EAN-13 = Expand
UPC-A Number System Character Transmission
This feature enables/disables transmission of the UPC-A number system character.
$CABNS01(CR)
UPC-A Number System Character = Transmit
$CABNS00(CR)
UPC-A Number System Character = Do not transmit
DEFAULT
Product Reference Guide 85
Enter/Exit Programming Mode
UPC-A 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded.
$CAB2D00(CR)
DEFAULT
EAN-13 2D Component =
Disable (2D component not required)
$CAB2D01(CR)
EAN-13 2D Component =
2D component must be decoded
$CEBEN01(CR)
UPC-E
The following options apply to the UPC-E symbology.
UPC-E Enable/Disable
When disabled, the reader will not read UPC-E bar codes.
$CEBEN00(CR)
UPC-E = Disable
DEFAULT
UPC-E = Enable
86 PowerScan™ PD9530/PBT9500/PM9500
$CEBCT01(CR)
Enter/Exit Programming Mode
UPC-E Check Character Transmission
Enable this option to transmit the check character along with UPC-E bar code data.
$CEBCT00(CR)
UPC-E Check Character Transmission = Don’t Send
DEFAULT
UPC-E Check Character Transmission = Send
$CEB2D01(CR)
UPC-E 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
$CEB2D00(CR)
DEFAULT
UPC-E 2D Component =
Disable (2D component not required)
UPC-E 2D Component =
2D component must be decoded
Product Reference Guide 87
Enter/Exit Programming Mode
Expand UPC-E to EAN-13
Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
$CEB3B00(CR)
DEFAULT
UPC-E to EAN-13 = Don’t Expand
$CEB3B01(CR)
UPC-E to EAN-13 = Expand
$CEBAB01(CR)
Expand UPC-E to UPC-A
Expands UPC-E data to the UPC-A data format.
$CEBAB00(CR)
DEFAULT
UPC-E to UPC-A = Don’t Expand
UPC-E to UPC-A = Expand
88 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
UPC-E Number System Character Transmission
This feature enables/disables transmission of the UPC-E system number character.
$CEBNS00(CR)
$CEBNS01(CR)
UPC-E Number System Character = Transmit
UPC-E Number System Character = Do not transmit
DEFAULT
GTIN FORMATTING
This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format.
If add-on information is present on the base label prior to the conversion taking place, the add-on information will be appended to the converted GTIN label.
DEFAULT
$CGBEN01(CR)
GTIN Formatting = Enable
$CGBEN00(CR)
GTIN Formatting = Disable
Product Reference Guide 89
Enter/Exit Programming Mode
EAN 13 (JAN 13)
The following options apply to the EAN 13 (Jan 13) symbology.
EAN 13 Enable/Disable
When disabled, the reader will not read EAN 13/JAN 13 bar codes.
$C3BEN00(CR)
$C3BEN01(CR)
EAN 13 = Disable
DEFAULT
EAN 13 = Enable
$C3BCT01(CR)
EAN 13 Check Character Transmission
Enable this option to transmit the check character along with EAN 13 bar code data.
$C3BCT00(CR)
EAN 13 Check Character Transmission = Don’t Send
DEFAULT
EAN 13 Check Character Transmission = Send
90 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
EAN-13 Flag 1 Character
Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label.
$C3BF100(CR)
$C3BF101(CR)
EAN-13 Flag 1 Char= Transmit
EAN-13 Flag 1 Char= Don’t transmit
DEFAULT
$C3BIS01(CR)
EAN-13 ISBN Conversion
This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.
$C3BIS00(CR)
DEFAULT
EAN-13 ISBN Conversion = Disable
EAN-13 ISBN Conversion = Convert to ISBN
Product Reference Guide 91
Enter/Exit Programming Mode
EAN-13 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded.
$C3B2D00(CR)
DEFAULT
EAN-13 2D Component =
Disable (2D component not required)
$C3B2D01(CR)
EAN-13 2D Component =
2D component must be decoded
$C3BIN01(CR)
ISSN
The following options apply to the ISSN symbology.
ISSN Enable/Disable
Enables/disables conversion of EAN/JAN13 Bookland labels starting with
977 to ISSN labels.
$C3BIN00(CR)
DEFAULT
ISSN = Disable
ISSN = Enable
92 PowerScan™ PD9530/PBT9500/PM9500
$C8BEN01(CR)
Enter/Exit Programming Mode
EAN 8 (JAN 8)
The following options apply to the EAN 8 (Jan 8) symbology.
EAN 8 Enable/Disable
When disabled, the reader will not read EAN 8/JAN 8 bar codes.
$C8BEN00(CR)
EAN 8 = Disable
DEFAULT
EAN 8 = Enable
$C8BCT01(CR)
EAN 8 Check Character Transmission
Enable this option to transmit the check character along with EAN 8 bar code data.
$C8BCT00(CR)
EAN 8 Check Character Transmission = Don’t Send
DEFAULT
EAN 8 Check Character Transmission = Send
Product Reference Guide 93
Enter/Exit Programming Mode
Expand EAN 8 to EAN 13
Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13.
$C8B3B00(CR)
DEFAULT
Expand EAN 8 to EAN 13 = Disable
$C8B3B01(CR)
Expand EAN 8 to EAN 13 = Enable
$C8B2D01(CR)
EAN 8 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
$C8B2D00(CR)
DEFAULT
EAN 8 2D Component =
Disable (2D component not required)
EAN 8 2D Component =
2D component must be decoded
94 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
UPC/EAN GLOBAL SETTINGS
This section provides configuration settings for UPC-A, UPC-E, EAN 13 and
EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description.
$CPWEN01(CR)
UPC/EAN Price Weight Check
This feature enables/disables calculation and verification of price/weight check digits.
$CPWEN00(CR)
DEFAULT
Price Weight Check = Disabled
Price Weight Check = 4-digit price-weight check
$CPWEN02(CR)
Price Weight Check = 5-digit price-weight check
$CPWEN03(CR)
Price Weight Check = European 4-digit price-weight check
$CPWEN04(CR)
Price Weight Check = European 5-digit price-weight check
Product Reference Guide 95
Enter/Exit Programming Mode
UPC/EAN Quiet Zones
This feature specifies the number of quiet zones for UPC/EAN labels. Quiet zones are blank areas at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label. The property applies to all EAN-
UPC symbologies globally and to the ADDONs.
$CUNLO02(CR)
DEFAULT
UPC/EAN Quiet Zones = Two Modules
$CUNLO03(CR)
UPC/EAN Quiet Zones = Three Modules
96 PowerScan™ PD9530/PBT9500/PM9500
$CADO201(CR)
Enter/Exit Programming Mode
ADD-ONS
Contact Customer Support for advanced programming of optional and conditional add-ons.
Optional Add-ons
The reader can be enabled to optionally read the following add-ons (supplementals):
If a UPC/EAN base label and an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/EAN base label is decoded without an add-on, the base label will be transmitted without an add-on.
Conditional add-on settings (if enabled) are considered by the reader before optional add-on settings.
$CADO200(CR)
DEFAULT
Optional Add-Ons = Disable P2
Optional Add-Ons = Enable P2
DEFAULT
$CADO500(CR)
Optional Add-Ons = Disable P5
$CADO501(CR)
Optional Add-Ons = Enable P5
DEFAULT
$CADO800(CR)
Optional Add-Ons = Disable GS1-128
$CADO801(CR)
Optional Add-Ons = Enable GS1-128
Product Reference Guide 97
Enter/Exit Programming Mode
Optional Add-On Timer
This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see
"Optional GS1-128 Add-On Timer" on page 100.)
$CADOT01(CR)
Optional Add-on Timer = 10ms
$CADOT02(CR)
Optional Add-on Timer = 20ms
$CADOT03(CR)
Optional Add-on Timer = 30ms
$CADOT04(CR)
Optional Add-on Timer = 40ms
$CADOT05(CR)
Optional Add-on Timer = 50ms
$CADOT07(CR)
Optional Add-on Timer = 70ms
$CADOT06(CR)
Optional Add-on Timer = 60ms
DEFAULT
98
$CADOT0A(CR)
Optional Add-on Timer = 100ms
PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Optional Add-On Timer (continued)
$CADOT0C(CR)
Optional Add-on Timer = 120ms
$CADOT0E(CR)
Optional Add-on Timer = 140ms
$CADOT10(CR)
Optional Add-on Timer = 160ms
$CADOT12(CR)
Optional Add-on Timer = 180ms
$CADOT14(CR)
Optional Add-on Timer = 200ms
$CADOT16(CR)
Optional Add-on Timer = 220ms
$CADOT18(CR)
Optional Add-on Timer = 240ms
$CADOT1A(CR)
Optional Add-on Timer = 260ms
Product Reference Guide 99
Enter/Exit Programming Mode
Optional Add-On Timer (continued)
$CADOT1C(CR)
Optional Add-on Timer = 280ms
$CADOT1E(CR)
Optional Add-on Timer = 300ms
$CADUT01(CR)
Optional GS1-128 Add-On Timer
This option sets the timer expiration value to read the added part after reading the linear EAN/UPC part. For UPC/EAN add-ons other than those of that type, see
"Optional Add-On Timer" on page 98.
$CADUT00(CR)
DEFAULT
Optional GS1-128 Add-On Timer = Disable
Optional GS1-128 Add-On Timer = 10ms
$CADUT02(CR)
Optional GS1-128 Add-On Timer = 20ms
$CADUT03(CR)
Optional GS1-128 Add-On Timer = 30ms
100 PowerScan™ PD9530/PBT9500/PM9500
Optional GS1-128 Add-On Timer (continued)
$CADUT04(CR)
Enter/Exit Programming Mode
Optional GS1-128 Add-On Timer = 40ms
$CADUT05(CR)
Optional GS1-128 Add-On Timer = 50ms
$CADUT06(CR)
Optional GS1-128 Add-On Timer = 60ms
$CADUT07(CR)
Optional GS1-128 Add-On Timer = 70ms
$CADUT0A(CR)
Optional GS1-128 Add-On Timer = 100ms
$CADUT0C(CR)
Optional GS1-128 Add-On Timer = 120ms
$CADUT0E(CR)
Optional GS1-128 Add-On Timer = 140ms
$CADUT10(CR)
Optional GS1-128 Add-On Timer = 160ms
Product Reference Guide 101
Enter/Exit Programming Mode
Optional GS1-128 Add-On Timer (continued)
$CADUT12(CR)
Optional GS1-128 Add-On Timer = 180ms
$CADUT14(CR)
Optional GS1-128 Add-On Timer = 200ms
$CADUT16(CR)
Optional GS1-128 Add-On Timer = 220ms
$CADUT18(CR)
Optional GS1-128 Add-On Timer = 240ms
$CADUT1A(CR)
Optional GS1-128 Add-On Timer = 260ms
$CADUT1C(CR)
Optional GS1-128 Add-On Timer = 280ms
$CADUT1E(CR)
Optional GS1-128 Add-On Timer = 300ms
102 PowerScan™ PD9530/PBT9500/PM9500
$CC3EN01(CR)
Enter/Exit Programming Mode
CODE 39
The following options apply to the Code 39 symbology.
Code 39 Enable/Disable
$CC3EN00(CR)
Code 39 = Disable
DEFAULT
Code 39 = Enable
$CC3CC01(CR)
Code 39 Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data character
$CC3CC00(CR)
Code 39 Check Character Calculation = Don’t Calculate
DEFAULT
Code 39 Check Character Calculation =
Calculate Std Check
$CC3CC02(CR)
Code 39 Check Character Calculation =
Calculate Mod 7 Check
Product Reference Guide 103
Enter/Exit Programming Mode
Code 39 Check Character Calculation (continued)
$CC3CC04(CR)
Code 39 Check Character Calculation =
Enable Italian Post Check
$CC3CC08(CR)
Code 39 Check Character Calculation =
Enable Daimler Chrysler Check
Code 39 Check Character Transmission
Enable this option to transmit the check character along with Code 39 bar code data.
$CC3CT00(CR)
$CC3CT01(CR)
Code 39 Check Character Transmission = Send
Code 39 Check Character Transmission = Don’t Send
DEFAULT
104 PowerScan™ PD9530/PBT9500/PM9500
$CC3SS01(CR)
Enter/Exit Programming Mode
Code 39 Start/Stop Character Transmission
Enable this option to enable/disable transmission of Code 39 start and stop characters .
$CC3SS00(CR)
DEFAULT
Code 39 Start/Stop Character Transmission =
Don’t Transmit
Code 39 Start/Stop Character Transmission = Transmit
Code 39 Full ASCII
Enables/disables the translation of Code 39 characters to Code 39 full-
ASCII characters.
DEFAULT
$CC3FA00(CR)
Code 39 Full ASCII = Disable
$CC3FA01(CR)
Code 39 Full ASCII = Enable
Product Reference Guide 105
Enter/Exit Programming Mode
Code 39 Quiet Zones
This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label.
$CC3LO02(CR)
Code 39 Quiet Zones = Quiet Zones on two sides
$CC3LO03(CR)
DEFAULT
Code 39 Quiet Zones = Small Quiet Zones on two sides
$CC3LC01(CR)
Code 39 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CC3LC00(CR)
DEFAULT
Code 39 Length Control = Variable Length
Code 39 Length Control = Fixed Length
106 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Code 39 Set Length 1
first fixed length if in
Fixed Length Mode. Length includes the bar code’s
data characters only. The length can be set from 0 to 50 characters.
provides examples for setting Length 1. See
instructions on setting this feature.
Table 4. Code 39 Length 1 Setting Examples
2
3
STEP ACTION
1 Desired Setting
EXAMPLES
00 Characters 07 Characters 15 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODE 39 LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CC3L1
Select Code 39 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 02 = Length 1 is 2 Characters
CANCEL
Product Reference Guide 107
Enter/Exit Programming Mode
Code 39 Set Length 2
Mode, or the
second fixed length if in Fixed Length Mode. Length includes the bar code’s
check, data, and full-ASCII shift characters. The length does not include start/stop characters.
provides examples for setting Length 2. See
instructions on setting this feature.
Table 5. Code 39 Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
EXAMPLES
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 39 LENGTH 2 SETTING
4
5
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING .MODE
07 Characters
‘0’ and ‘7’
15 Characters
‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CC3L2
Select Code 39 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
108 PowerScan™ PD9530/PBT9500/PM9500
$CCTEN01(CR)
Enter/Exit Programming Mode
TRIOPTIC CODE
The following options apply to the Trioptic symbology.
Trioptic Code Enable/Disable
$CCTEN00(CR)
DEFAULT
Trioptic Code = Disable
Trioptic Code = Enable
$CP3EN01(CR)
CODE 32 (ITAL PHARMACEUTICAL CODE)
The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology.
Code 32 Enable/Disable
When disabled, the reader will not read Code 32 bar codes.
$CP3EN00(CR)
DEFAULT
Code 32 = Disable
Code 32 = Enable
Code 32 Feature Setting Exceptions
The following features are set for Code 32 by using these Code 39 settings:
Product Reference Guide 109
Enter/Exit Programming Mode
Code 32 Check Character Transmission
Enable this option to transmit the check character along with Code 32 bar code data.
$CP3CT00(CR)
DEFAULT
Code 32 Check Character Transmission = Don’t Send
$CP3CT01(CR)
Code 32 Check Character Transmission = Send
$CP3SS01(CR)
Code 32 Start/Stop Character Transmission
This option enables/disables transmission of Code 32 start and stop characters .
$CP3SS00(CR)
DEFAULT
Code 32 Start/Stop Character Transmission =
Don’t Transmit
Code 32 Start/Stop Character Transmission = Transmit
110 PowerScan™ PD9530/PBT9500/PM9500
$CCCEN01(CR)
Enter/Exit Programming Mode
CODE 39 CIP (FRENCH PHARMACEUTICAL)
The following options apply to the Code 39 CIP symbology.
Code 39 CIP Enable/Disable
Enables/Disables ability of the reader to decode Code 39 CIP labels.
DEFAULT
$CCCEN00(CR)
Code 39 CIP = Disable
Code 39 CIP = Enable
CODE 39 DANISH PPT
The following options apply to the Code 39 Danish PPT symbology.
Code 39 Danish PPT Enable/Disable
Enables/Disables AIM ID for Code 39 Danish PPT Codes.
DEFAULT
$CDPEN00(CR)
Code 39 Danish PPT = Disable
$CDPEN01(CR)
Code 39 Danish PPT = Enable
Product Reference Guide 111
Enter/Exit Programming Mode
CODE 39 LAPOSTE
The following options apply to the Code 39 LaPoste symbology.
Code 39 LaPoste Enable/Disable
Enables/disables the ability of the scanner to decode Code39 La Poste labels.
DEFAULT
$CLPEN01(CR)
Code 39 LaPoste = Enable
$CLPEN00(CR)
Code 39 LaPoste = Disable
$PZEN01(CR)
CODE 39 PZN
The following options apply to the Code 39 PZN symbology.
Code 39 PZN Enable/Disable
Enables/disables the ability of the scanner to decode Code39 PZN labels.
$PZEN00(CR)
DEFAULT
Code 39 PZN = Disable
Code 39 PZN = Enable
112 PowerScan™ PD9530/PBT9500/PM9500
$CC8EN01(CR)
Enter/Exit Programming Mode
CODE 128
The following options apply to the Code 128 symbology.
Code 128 Enable/Disable
When disabled, the reader will not read Code 128 bar codes.
$CC8EN00(CR)
Code 128 = Disable
DEFAULT
Code 128 = Enable
Expand Code 128 to Code 39
This feature enables/disables expansion of Code 128 labels to Code 39 labels.
DEFAULT
$CC8C300(CR)
Code 128 to Code 39 = Don’t Expand
$CC8C301(CR)
Code 128 to Code 39 = Expand
Product Reference Guide 113
Enter/Exit Programming Mode
Code 128 Check Character Transmission
Enable this option to transmit the check character along with Code 128 bar code data.
$CC8CT00(CR)
DEFAULT
Code 128 Check Character Transmission = Don’t Send
$CC8CT01(CR)
Code 128 Check Character Transmission = Send
$CC8TF01(CR)
Code 128 Function Character Transmission
Enables/disables transmission of Code128 function characters 1, 2, 3, and
4.
$CC8TF00(CR)
DEFAULT
Code 128 Function Character Transmission = Don’t Send
Code 128 Function Character Transmission = Send
114 PowerScan™ PD9530/PBT9500/PM9500
$CC8SC01(CR)
Enter/Exit Programming Mode
Code 128 Sub-Code Exchange Transmission
Enables/disables the transmission of “Sub-Code Exchange” characters (NOT transmitted by standard decoding).
$CC8SC00(CR)
DEFAULT
Code 128 Sub-Code Exchange Transmission = Disable
Code 128 Sub-Code Exchange Transmission = Enable
Code 128 Quiet Zones
This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.
$CC8LO02(CR)
$CC8LO03(CR)
Code 128 Quiet Zones = Small Quiet Zones on two sides
Code 128 Quiet Zones = Quiet Zones on two sides
DEFAULT
Product Reference Guide 115
Enter/Exit Programming Mode
Code 128 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. See
page 267 for more information.
$CC8LC00(CR)
DEFAULT
Code 128 Length Control = Variable Length
$CC8LC01(CR)
Code 128 Length Control = Fixed Length
116 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Code 128 Set Length 1
Specifies one of the bar code lengths for
. Length 1 is the minimum label length if in
Mode, or the first fixed length if in
Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 80 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 6. Code 128 Length 1 Setting Examples
2
3
STEP ACTION
1 Desired Setting
EXAMPLES
01 Character
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODE 128 LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters
‘0’ and ‘7’
15 Characters
‘1’ and ‘5’
80 Characters
‘8’ AND ‘0’
$CC8L1
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 01 = Length 1 is 1 Character
CANCEL
Product Reference Guide 117
Enter/Exit Programming Mode
Code 128 Set Length 2
Mode, or the
second fixed length if in Fixed Length Mode. Length includes the bar code’s
data characters only.
The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
instructions on setting this feature.
Table 7. Code 128 Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
EXAMPLES
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 128 LENGTH 2 SETTING
07 Characters 15 Characters
4
5
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
80 Characters
‘8’ and 0’
$CC8L2
Select Code 128 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 80 = Length 2 is 80 Characters
118 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
GS1-128
The following options apply to the GS1-128 symbology. (Also known as
USS-128, GS1-128, GTIN-128, UCC-128, EAN-128.)
GS1-128 Enable
This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are:
• Transmit GS1-128 labels in Code 128 data format.
• Transmit GS1-128 labels in GS1-128 data format.
• Do not transmit GS1-128 labels.
$CU8EN00CR)
GS1-128 = Transmit in Code 128 data format
$CU8EN01CR)
GS1-128 = Transmit in GS1-128 data format
DEFAULT
$CU8EN02CR)
GS1-128 = Do not transmit GS1-128 labels
$CU82D01(CR)
GS1-128 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded.
$CU82D00(CR)
DEFAULT
GS1-128 2D Component = Disable
GS1-128 2D Component = Enable
Product Reference Guide 119
Enter/Exit Programming Mode
CODE ISBT 128
The following options apply to the ISBT 128 symbology.
$CI8CE01(CR)
ISBT 128 Concatenation
Use this option to enable/disable ISBT128 concatenation of 2 labels.
$CI8CE00(CR)
DEFAULT
ISBN 128 Concatenation = Disable
ISBN 128 Concatenation = Enable
ISBT 128 Force Concatenation
When enabled, this feature forces concatenation for ISBT.
This option is only valid when
is enabled.
DEFAULT
$CI8FC01(CR)
ISBT 128 Force Concatenation = Enable
$CI8FC00(CR)
ISBT 128 Force Concatenation = Disable
120 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
ISBT 128 Concatenation Mode
Specifies the concatenation mode between Static and Dynamic.
This option is only valid when ISBT 128 Concatenation is enabled (see "
).
DEFAULT
$CI8CM01CR)
ISBT 128 Concatenation Mode = Dynamic
$CI8CM00CR)
ISBT 128 Concatenation Mode = Static
Product Reference Guide 121
Enter/Exit Programming Mode
ISBT 128 Dynamic Concatenation Timeout
Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
$CI8DT05(CR)
ISBT 128 Dynamic Concatenation Timeout = 50 msec
$CI8DT0A(CR)
ISBT 128 Dynamic Concatenation Timeout = 100 msec
DEFAULT
$CI8DT14(CR)
ISBT 128 Dynamic Concatenation Timeout = 200 msec
$CI8DT32(CR)
ISBT 128 Dynamic Concatenation Timeout = 500 msec
$CI8DT4B(CR)
ISBT 128 Dynamic Concatenation Timeout = 750 msec
$CI8DT64(CR)
ISBT 128 Dynamic Concatenation Timeout = 1 second
ISBT 128 Advanced Concatenation Options
To set up pairs of label types for concatenation, use the Datalogic Aladdin configura-
tion application or contact Datalogic Technical Support, as described on page 2
.
122 PowerScan™ PD9530/PBT9500/PM9500
$CI2EN01(CR)
Enter/Exit Programming Mode
INTERLEAVED 2 OF 5 (I 2 OF 5)
The following options apply to the I 2 of 5 symbology.
I 2 of 5 Enable/Disable
When disabled, the reader will not read I 2 of 5 bar codes.
$CI2EN00(CR)
DEFAULT
I 2 of 5 = Disable
I 2 of 5 = Enable
Product Reference Guide 123
Enter/Exit Programming Mode
I 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional I 2 of
5 check character. Combinations of these settings are possible via the Aladdin configuration utility, or contact Technical Support.
$CI2CC00(CR)
DEFAULT
I 2 of 5 Check Character Calculation = Disable
$CI2CC01(CR)
I 2 of 5 Check Character Calculation = Check Standard
(Modulo 10)
$CI2CC02(CR)
I 2 of 5 Check Character Calculation = Check German Parcel
$CI2CC04(CR)
I 2 of 5 Check Character Calculation = Check DHL
$CI2CC08(CR)
I 2 of 5 Check Character Calculation = Check Daimler Chrysler
$CI2CC10(CR)
I 2 of 5 Check Character Calculation = Check Bosch
$CI2CC20(CR)
I 2 of 5 Check Character Calculation = Italian Post
124 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
I 2 of 5 Check Character Transmission
Enable this option to transmit the check character along with I 2 of 5 bar code data.
$CI2CT00(CR)
$CI2CT01(CR)
I 2 of 5 Check Character Transmission = Send
I 2 of 5 Check Character Transmission = Don’t Send
DEFAULT
$CI2LC01(CR)
I 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CI2LC00(CR)
DEFAULT
I 2 of 5 Length Control = Variable Length
I 2 of 5 Length Control = Fixed Length
Product Reference Guide 125
Enter/Exit Programming Mode
I 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for
.
Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters in increments of two.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 8. I 2 of 5 Length 1 Setting Examples
3
4
STEP ACTION
1 Desired Setting
2
Pad with leading zeroes to yield two digits
EXAMPLES
2 Characters
02
5
6
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT I 2 of 5 LENGTH 1 SETTING
Scan Two Characters From
‘0’ and ‘2’
Scan ENTER/EXIT PROGRAMMING MODE
6 Characters
06
‘0’ and ‘6’
14 Characters
14
‘1’ and ‘4’
50 Characters
50
‘5’ AND ‘0’
$CI2L1
Select I 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 06 = Length 1 is 6 Characters
CANCEL
126 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
I 2 of 5 Set Length 2
Mode, or the second fixed length if in
Fixed Length Mode. The length includes the bar
code’s check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
instructions on setting this feature.
Table 9. I 2 of 5 Length 2 Setting Examples
3
4
STEP
1
2
5
6
ACTION
Desired Setting
EXAMPLES
Ignore This
Length
Pad with leading zeroes to yield two digits
00
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT I 2 OF 5 LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
4 Characters
04
‘0’ and ‘4’
14 Characters
14
‘1’ and ‘4’
50 Characters
50
‘5’ AND ‘0’
$CI2L2
Select I 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
Product Reference Guide 127
Enter/Exit Programming Mode
INTERLEAVED 2 OF 5 CIP HR
The following options apply to the Interleaved 2 of 5 CIP HR symbology.
Interleaved 2 of 5 CIP HR Enable/Disable
Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels.
DEFAULT
$CCHEN00(CR)
Interleaved 2 of 5 CIP HR = Disable
$CCHEN01(CR)
Interleaved 2 of 5 CIP HR = Enable
FOLLETT 2 OF 5
The following options apply to the Follett 2 of 5 symbology.
$CF2EN01(CR)
Follett 2 of 5 Enable/Disable
Enables/Disables ability of reader to decode Plessey labels.
$CF2EN00(CR)
DEFAULT
Follett 2 of 5 = Disable
Follett 2 of 5 = Enable
128 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
STANDARD 2 OF 5
The following options apply to the Standard 2 of 5 symbology.
Standard 2 of 5 Enable/Disable
When disabled, the reader will not read Standard 2 of 5 bar codes.
DEFAULT
$C2SEN01(CR)
Standard 2 of 5 = Enable
$C2SEN00(CR)
Standard 2 of 5 = Disable
$CS2CC01(CR)
Standard 2 of 5 Check Character Calculation
This option enables/disables calculation and verification of an optional
Standard 2 of 5 check character.
$CS2CC00(CR)
DEFAULT
Standard 2 of 5 Check Character Calculation = Disable
Standard 2 of 5 Check Character Calculation = Enable
Product Reference Guide 129
Enter/Exit Programming Mode
Standard 2 of 5 Check Character Transmission
This feature enables/disables transmission of an optional Standard 2 of 5 check character.
$CS2CT00(CR)
$CS2CT01(CR)
Standard 2 of 5 Check Character Transmission = Send
Standard 2 of 5 Check Character Transmission =
Don’t Send
DEFAULT
$CS2LC01(CR)
Standard 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CS2LC00(CR)
DEFAULT
Standard 2 of 5 Length Control = Variable Length
Standard 2 of 5 Length Control = Fixed Length
130 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Standard 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in
Fixed Length Mode. Length includes the bar code’s
check and data characters. The length can be set from 1 to 50 characters.
provides some examples for setting Length 1. See
want detailed instructions on setting this feature.
Table 10. Standard 2 of 5 Length 1 Setting Examples
2
3
STEP ACTION
1 Desired Setting
EXAMPLES
01 Character
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters 15 Characters
Scan SELECT STANDARD 2 OF 5 LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CS2L1
Select Standard 2 of 5 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 08 = Length 1 is 8 Characters
CANCEL
Product Reference Guide 131
Enter/Exit Programming Mode
Standard 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for
. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in
Fixed Length Mode. Length includes the bar
code’s check and data characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
instructions on setting this feature.
Table 11. Standard 2 of 5 Length 2 Setting Examples
2
3
STEP ACTION
1
Desired Setting (pad with leading zeroes)
4
5
EXAMPLES
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters 15 Characters
Scan SELECT STANDARD 2 OF 5 LENGTH 2 SETTING
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CS2L2
Select Standard 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
132 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
INDUSTRIAL 2 OF 5
The following options apply to the Industrial 2 of 5 symbology.
$CU2EN01(CR)
Industrial 2 of 5 Enable/Disable
Enables/Disables ability of reader to decode Industrial 2 of 5 labels.
$CU2EN00(CR)
DEFAULT
Industrial 2 of 5 = Disable
Industrial 2 of 5 = Enable
$CU2CC01(CR)
Industrial 2 of 5 Check Character Calculation
Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
$CU2CC00(CR)
DEFAULT
Industrial 2 of 5 Check Character Calculation = Disable
Industrial 2 of 5 Check Character Calculation = Enable
Product Reference Guide 133
Enter/Exit Programming Mode
Industrial 2 of 5 Check Character Transmission
Enables/disables transmission of an Industrial 2 of 5 check character.
$CU2CT00(CR)
$CU2CT01(CR)
Industrial 2 of 5 Check Character Transmission = Enable
Industrial 2 of 5 Check Character Transmission = Disable
DEFAULT
$CU2LC01(CR)
Industrial 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CU2LC00(CR)
DEFAULT
Industrial 2 of 5 Length Control = Variable Length
Industrial 2 of 5 = Fixed Length
134 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Industrial 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for Industrial 2 of 5
. Length 1 is the minimum label length if in Variable Length
Mode, or the first fixed length if in Fixed Length
Mode. Length includes the bar code’s data characters only. The length can be set from 0 to 50 characters.
provides some examples for setting Length 1. See
want detailed instructions on setting this feature.
Table 12. Industrial 2 of 5 Length 1 Setting Examples
2
3
STEP ACTION
1 Desired Setting
EXAMPLES
00 Characters 07 Characters 15 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CU2L1
Select Industrial 2 of 5 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 01 = Length 1 is 1 Character
CANCEL
Product Reference Guide 135
Enter/Exit Programming Mode
Industrial 2 of 5 Set Length 2
This feature specifies one of the bar code lengths for Industrial 2 of 5
. Length 2 is the maximum label length if in Variable Length
Mode, or the second fixed length if in
Fixed Length Mode. Length includes
the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
instructions on setting this feature.
Table 13. Industrial 2 of 5 Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
EXAMPLES
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
3
4
5
07 Characters 15 Characters
Scan SELECT INDUSTRIAL 2 OF 5 LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CU2L2
Select Industrial 2 of5 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
136 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
CODE IATA
The following options apply to the IATA symbology.
$CIAEN01(CR)
IATA Enable/Disable
Enables/Disables the ability of the reader to decode IATA labels.
$CIAEN00(CR)
DEFAULT
IATA = Disable
IATA = Enable
IATA Check Character Transmission
Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
$CIACT01(CR)
IATA Check Character Transmission = Enable
$CIACT00(CR)
IATA Check Character Transmission = Disable
DEFAULT
Product Reference Guide 137
Enter/Exit Programming Mode
CODABAR
The following options apply to the Codabar symbology.
Codabar Enable/Disable
When disabled, the reader will not read Codabar bar codes.
$CCBEN00(CR)
DEFAULT
Codabar = Disable
$CCBEN01(CR)
Codabar = Enable
$CCBCC01(CR)
Codabar Check Character Calculation
Enable this option to enables/disables calculation and verification of an optional Codabar check character. When disabled, any check character in the label is treated as a data character
$CCBCC00(CR)
DEFAULT
Codabar Check Character Calculation =
Don’t Calculate
Codabar Check Character Calculation = Enable AIM standard check char.
$CCBCC02(CR)
Codabar Check Character Calculation =
Enable Modulo 10 check char.
138 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Codabar Check Character Transmission
Enable this option to transmit the check character along with Codabar bar code data.
$CCBCT00(CR)
$CCBCT01(CR)
Codabar Check Character Transmission = Send
Codabar Check Character Transmission = Don’t Send
DEFAULT
Codabar Start/Stop Character Transmission
Enable this option to enable/disable transmission of Codabar start and stop characters .
$CCBSS00(CR)
$CCBSS01(CR)
Codabar Start/Stop Character Transmission = Transmit
Codabar Start/Stop Character Transmission =
Don’t Transmit
DEFAULT
Product Reference Guide 139
Enter/Exit Programming Mode
Codabar Start/Stop Character Set
This option specifies the format of transmitted Codabar start/stop characters
.
$CCBSC00(CR)
Codabar Check Character Set = ABCD/TN*E
$CCBSC01(CR)
Codabar Check Character Set = ABCD/ABCD
$CCBSC03(CR)
Codabar Check Character Set = abcd/abcd
$CCBSC02(CR)
Codabar Check Character Set = abcd/tn*e
DEFAULT
$CCBSM01(CR)
Codabar Start/Stop Character Match
When enabled, this option requires that start and stop characters match .
$CCBSM00(CR)
DEFAULT
Codabar Start/Stop Character Match =
Don’t Require Match
Codabar Start/Stop Character Match = Require Match
140 PowerScan™ PD9530/PBT9500/PM9500
$CCBLO03(CR)
Enter/Exit Programming Mode
Codabar Quiet Zones
Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.
$CCBLO02(CR)
DEFAULT
Codabar Quiet Zones = Quiet Zones on two sides
Codabar Quiet Zones = Small Quiet Zones on two sides
$CCBLC01(CR)
Codabar Length Control
This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CCBLC00(CR)
DEFAULT
Codabar Length Control = Variable Length
Codabar Length Control = Fixed Length
Product Reference Guide 141
Enter/Exit Programming Mode
Codabar Set Length 1
This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length Control
Mode. Length includes the bar code’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 14. Codabar Length 1 Setting Examples
2
3
STEP ACTION
1
Desired Setting (and pad with leading zeroes)
4
5
EXAMPLES
03 Characters 09 Characters 15 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODABAR LENGTH 1 SETTING
Scan Two Characters From
‘0’ and ‘3’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘9’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CCBL1
Select Codabar Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 03 = Length 1 is 3 Characters
CANCEL
142 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Codabar Set Length 2
This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length Control
. Length 2 is the maximum label length if in
Variable Length Mode, or the second fixed length if in Fixed Length Mode.
The length includes the bar code’s start, stop, check and data characters.
The length must include at least one data character.
The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
for detailed instructions on setting this feature.
Table 15. Codabar Length 2 Setting Examples
2
3
STEP ACTION
1
Desired Setting (and pad with leading zeroes)
4
5
EXAMPLES
00 Ignore This
Length
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODABAR LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters 15 Characters
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CCBL2
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
Product Reference Guide 143
Enter/Exit Programming Mode
ABC CODABAR
The following options apply to the ABC Codabar symbology.
ABC Codabar Enable/Disable
Enables/Disables ability of reader to decode ABC Codabar labels.
DEFAULT
$CCBAB00(CR)
ABC Codabar = Disable
$CCBAB01(CR)
ABC Codabar = Enable
ABC Codabar Concatenation Mode
Specifies the concatenation mode between Static and Dynamic.
DEFAULT
$CCBCM01(CR)
ABC Codabar Concatenation Mode = Dynamic
$CCBCM00(CR)
ABC Codabar Concatenation Mode = Static
144 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
ABC Codabar Dynamic Concatenation Timeout
Specifies the timeout in 10-millisecond ticks used by the ABC Codabar
Dynamic Concatenation Mode.
$CCBDT05(CR)
ABC Codabar Dynamic Concatenation Timeout =
50 msec
$CCBDT0A(CR)
ABC Codabar Dynamic Concatenation Timeout =
100 msec
DEFAULT
$CCBDT14(CR)
ABC Codabar Dynamic Concatenation Timeout =
200 msec
$CCBDT32(CR)
ABC Codabar Dynamic Concatenation Timeout =
500 msec
$CCBDT4B(CR)
ABC Codabar Dynamic Concatenation Timeout =
750 msec
$CCBDT64(CR)
ABC Codabar Dynamic Concatenation Timeout =
1 Second
Product Reference Guide 145
Enter/Exit Programming Mode
ABC Codabar Force Concatenation
Forces labels starting or ending with D to be concatenated.
DEFAULT
$CCBFC00(CR)
ABC Codabar Force Concatenation = Disable
$CCBFC01(CR)
ABC Codabar Force Concatenation = Enable
146 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
CODE 11
The following options apply to the Code 11 symbology.
$CC1EN01(CR)
Code 11 Enable/Disable
When disabled, the reader will not read Code 11 bar codes.
$CC1EN00(CR)
DEFAULT
Code 11 = Disable
Code 11 = Enable
Code 11 Check Character Calculation
This option enables/disables calculation and verification of optional Code
11 check character.
$CC1CC00(CR)
Code 11 Check Character Calculation = Disable
$CC1CC01(CR)
Code 11 Check Character Calculation = Check C
$CC1CC03(CR)
Code 11 Check Character Calculation = Check C and K
$CC1CC02(CR)
Code 11 Check Character Calculation = Check K
DEFAULT
Product Reference Guide 147
Enter/Exit Programming Mode
Code 11 Check Character Transmission
This feature enables/disables transmission of an optional Code 11 check character.
$CC1CT00(CR)
$CC1CT01(CR)
Code 11 Check Character Transmission = Send
Code 11 Check Character Transmission = Don’t Send
DEFAULT
$CC1LC01(CR)
Code 11 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CC1LC00(CR)
DEFAULT
Code 11 Length Control = Variable Length
Code 11 Length Control = Fixed Length
148 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Code 11 Set Length 1
first fixed length if in
Fixed Length Mode. Length includes the bar code’s
check and data characters. The length can be set from 2 to 50 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 16. Code 11 Length 1 Setting Examples
2
3
STEP ACTION
1
Desired Setting (pad with leading zeroes)
4
5
EXAMPLES
02 Characters 07 Characters 15 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODE 11 LENGTH 1 SETTING
Scan Two Characters From
‘0’ and ‘2’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CC1L1
Select Code 11 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 04 = Length 1 is 4 Characters
CANCEL
Product Reference Guide 149
Enter/Exit Programming Mode
Code 11 Set Length 2
Mode, or the
second fixed length if in Fixed Length Mode. Length includes the bar code’s
check and data characters.
The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
instructions on setting this feature.
Table 17. Code 11 Length 2 Setting Examples
2
3
STEP ACTION
1
Desired Setting (pad with leading zeroes)
4
5
EXAMPLES
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODE 11 LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters 15 Characters
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ and 0’
$CC1.2
Select Code 11 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
150 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
GS1 DATABAR™ OMNIDIRECTIONAL
The following options apply to the GS1 DataBar™ Omnidirectional (formerly
RSS-14) symbology.
$C4BEN01(CR)
GS1 DataBar™ Omnidirectional Enable/Disable
When disabled, the reader will not read GS1 DataBar™ Omnidirectional bar codes.
$C4BEN00(CR)
DEFAULT
GS1 DataBar™ Omnidirectional = Disable
GS1 DataBar™ Omnidirectional = Enable
$C4BU801(CR)
GS1 DataBar™ Omnidirectional GS1-128 Emulation
When enabled, GS1 DataBar™ Omnidirectional bar codes will be translated to the GS1-128 label data format.
$C4BU800(CR)
DEFAULT
GS1 DataBar™ Omnidirectional GS1-128 Emulation = Disable
GS1 DataBar™ Omnidirectional GS1-128 Emulation = Enable
Product Reference Guide 151
Enter/Exit Programming Mode
GS1 DataBar™ Omnidirectional 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
$C4B2D00(CR)
DEFAULT
GS1 DataBar™ Omnidirectional 2D Component =
Disable (2D component not required)
$C4B2D01(CR)
GS1 DataBar™ Omnidirectional 2D Component =
2D component must be decoded
GS1 DATABAR™ EXPANDED
The following options apply to the GS1 DataBar™ Expanded (formerly RSS
Expanded) symbology.
GS1 DataBar™ Expanded Enable/Disable
When disabled, the reader will not read GS1 DataBar™ Expanded bar codes.
DEFAULT
$CXBEN00(CR)
GS1 DataBar™ Expanded = Disable
$CXBEN01(CR)
GS1 DataBar™ Expanded = Enable
152 PowerScan™ PD9530/PBT9500/PM9500
$CXBU801(CR)
Enter/Exit Programming Mode
GS1 DataBar™ Expanded GS1-128 Emulation
When enabled, GS1 DataBar™ Expanded bar codes will be translated to the
GS1-128 label data format.
$CXBU800(CR)
DEFAULT
GS1 DataBar™ Expanded GS1-128 Emulation = Disable
GS1 DataBar™ Expanded GS1-128 Emulation = Enable
$CXB2D01(CR)
GS1 DataBar™ Expanded 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded.
$CXB2D00(CR)
DEFAULT
GS1 DataBar™ Expanded 2D Component = Disable
GS1 DataBar™ Expanded 2D Component = Enable
Product Reference Guide 153
Enter/Exit Programming Mode
GS1 DataBar™ Expanded Length Control
This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar™ Expanded symbology.
Variable Length:
For variable-length decoding, a minimum length may be set.
Fixed Length:
For fixed-length decoding, two different lengths may be set.
$CXBLC00(CR)
DEFAULT
GS1 DataBar™ Expanded Length Control =
Variable Length
$CXBLC01(CR)
GS1 DataBar™ Expanded Length Control = Fixed Length
154 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
GS1 DataBar™ Expanded Set Length 1
This feature specifies one of the bar code lengths for GS1 DataBar™
Expanded Length Control . Length 1 is the minimum label length if in
Variable Length Mode, or the first fixed length if in Fixed Length
Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 74 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 18. GS1 DataBar™ Expanded Length 1 Setting Examples
2
3
STEP ACTION
1 Desired Setting
EXAMPLES
01 Character
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters 52 Characters
Scan SELECT GS1 DataBar™ EXPANDED LENGTH 1SETTING
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘5’ and ‘2’
74 Characters
‘7’ AND ‘4’
$CXBL1
Select GS1 DataBar™ Expanded Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 01 = Length 1 is 1 Character
CANCEL
Product Reference Guide 155
Enter/Exit Programming Mode
GS1 DataBar™ Expanded Set Length 2
This feature specifies one of the bar code lengths for GS1 DataBar™
Expanded Length Control . Length 2 is the maximum label length if in
Variable Length Mode, or the second fixed length if in Fixed Length Mode.
Length includes the bar code’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
instructions on setting this feature.
Table 19. GS1 DataBar™ Expanded Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
EXAMPLES
00 (ignore second length)
Scan ENTER/EXIT PROGRAMMING MODE
3
07 Characters 52 Characters
Scan SELECT GS1 DataBar™ EXPANDED LENGTH 2 SETTING
4
5
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘5’ and ‘2’
74 Characters
‘7’ and ‘4’
$CXBL2
Select GS1 DataBar™ Expanded Set Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 74 = Length 2 is 74 Characters
156 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
GS1 DATABAR™ LIMITED
The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology.
GS1 DataBar™ Limited Enable/Disable
When disabled, the reader will not read GS1 DataBar™ Limited bar codes.
DEFAULT
$CLBEN00(CR)
GS1 DataBar™ Limited = Disable
$CLBEN01(CR)
GS1 DataBar™ Limited = Enable
$CLBU801(CR)
GS1 DataBar™ Limited GS1-128 Emulation
When enabled, GS1 DataBar™ Limited bar codes will be translated to the
GS1-128 label data format.
$CLBU800(CR)
DEFAULT
GS1 DataBar™ Limited GS1-128 Emulation = Disable
GS1 DataBar™ Limited GS1-128 Emulation = Enable
Product Reference Guide 157
Enter/Exit Programming Mode
GS1 DataBar™ Limited 2D Component
This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded.
$CLB2D00(CR)
DEFAULT
GS1 DataBar™ Limited 2D Component =
Disable (2D component not required)
$CLB2D01(CR)
GS1 DataBar™ Limited 2D Component =
2D component must be decoded
$CC9EN01(CR)
CODE 93
The following options apply to the Code 93 symbology.
Code 93 Enable/Disable
Enables/Disables ability of reader to decode Code 93 labels.
$CC9EN00(CR)
DEFAULT
Code 93 = Disable
Code 93 = Enable
158 PowerScan™ PD9530/PBT9500/PM9500
$CC9CC01(CR)
Enter/Exit Programming Mode
Code 93 Check Character Calculation
Enables/disables calculation and verification of an optional Code 93 check character.
$CC9CC00(CR)
Code 93 Check Character Calculation = Disable
Code 93 Check Character Calculation = Enable Check C
$CC9CC03(CR)
Code 93 Check Character Calculation =
Enable Check C and K
$CC9CC02(CR)
Code 93 Check Character Calculation = Enable Check K
DEFAULT
Code 93 Check Character Transmission
Enables/disables transmission of an optional Code 93 check character.
$CC9CT00(CR)
$CC9CT01(CR)
Code 93 Check Character Transmission = Enable
Code 93 Check Character Transmission = Disable
DEFAULT
Product Reference Guide 159
Enter/Exit Programming Mode
Code 93 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CC9LC00(CR)
DEFAULT
Code 93 Length Control = Variable Length
$CC9LC01(CR)
Code 93 = Fixed Length
160 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Code 93 Set Length 1
Specifies one of the bar code lengths for Code 93 Length Control . Length 1
is the minimum label length if in
Mode, or the first fixed length if in
Mode. Length includes the bar code’s data characters only. The length can be set from 01 to 50 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 20. Code 93 Length 1 Setting Examples
2
3
STEP ACTION
1 Desired Setting
EXAMPLES
01 Characters 07 Characters 15 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT CODE 93 LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CC9L1
Select Code 93 Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 01 = Length 1 is 1 Character
Product Reference Guide 161
Enter/Exit Programming Mode
Code 93 Set Length 2
Mode, or the
second fixed length if in Fixed Length Mode. Length includes the bar code’s
check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
instructions on setting this feature.
Table 21. CODE 93 Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
EXAMPLES
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
5
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters 15 Characters
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CC9L2
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
162 PowerScan™ PD9530/PBT9500/PM9500
$CC9LO03(CR)
Code 93 Quiet Zones
Enables/disables quiet zones for Code 93.
$CC9LO02(CR)
Enter/Exit Programming Mode
Code 93 Quiet Zones = Quiet Zones on two sides
DEFAULT
Code 93 Quiet Zones = Small Quiet Zones on two sides
MSI
The following options apply to the MSI symbology.
$CMSEN01(CR)
MSI Enable/Disable
Enables/Disables ability of reader to decode MSI labels.
$CMSEN00(CR)
DEFAULT
MSI = Disable
MSI = Enable
Product Reference Guide 163
Enter/Exit Programming Mode
MSI Check Character Calculation
Enables/Disables calculation and verification of an optional MSI check character.
$CMSCC00(CR)
$CMSCC01(CR)
MSI Check Character Calculation = Disable
DEFAULT
MSI Check Character Calculation = Enable Mod10
$CMSCC02(CR)
MSI Check Character Calculation = Enable Mod11/10
$CMSCC03(CR)
MSI Check Character Calculation = Enable Mod10/10
MSI Check Character Transmission
Enables/disables transmission of an MSI check character.
$CMSCT00(CR)
$CMSCT01(CR)
MSI Check Character Transmission = Enable
MSI Check Character Transmission = Disable
DEFAULT
164 PowerScan™ PD9530/PBT9500/PM9500
$CMSLC01(CR)
Enter/Exit Programming Mode
MSI Length Control
This feature specifies either variable length decoding or fixed length decoding for the MSI symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CMSLC00(CR)
DEFAULT
MSI Length Control = Variable Length
MSI = Fixed Length
Product Reference Guide 165
Enter/Exit Programming Mode
MSI Set Length 1
This feature specifies one of the bar code lengths for MSI Length Control
.
Length 1 is the minimum label length if in
characters only. The length can be set from 01 to 50 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 22. MSI Length 1 Setting Examples
2
3
STEP ACTION
1 Desired Setting
EXAMPLES
01 Characters 07 Characters 15 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT MSI LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CMSL1
Select MSI Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 01 = Length 1 is 1 Character
CANCEL
166 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
MSI Set Length 2
This feature specifies one of the bar code lengths for MSI Length Control
.
Length 2 is the maximum label length if in Variable Length Mode, or the
second fixed length if in
Fixed Length Mode. Length includes the bar code’s
check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
for detailed instructions on setting this feature.
Table 23. MSI Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
EXAMPLES
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
3
4
5
Scan SELECT MSI LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters 15 Characters
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CMSL2
Select MSI Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
Product Reference Guide 167
Enter/Exit Programming Mode
PLESSEY
The following options apply to the Plessey symbology.
$CPLEN01CR)
Plessey Enable/Disable
Enables/Disables ability of reader to decode Plessey labels.
$CPLEN00CR)
DEFAULT
Plessey = Disable
Plessey = Enable
$CPLCC01(CR)
Plessey Check Character Calculation
Enables/Disables calculation and verification of an optional Plessey check character.
$CPLCC00(CR)
Plessey Check Character Calculation =
Enable Plessey std. check char. verification
Plessey Check Character Calculation = Disable
DEFAULT
$CPLCC02(CR)
Plessey Check Character Calculation =
Enable Anker check char. verification
$CPLCC03(CR)
Plessey Check Character Calculation =
Enable Plessey std. and Anker check char verification
168 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Plessey Check Character Transmission
Enables/disables transmission of an MSI check character.
$CPLCT00(CR)
$CPLCT01(CR)
Plessey Check Character Transmission = Enable
Plessey Check Character Transmission = Disable
DEFAULT
$CPLLC01(CR)
Plessey Length Control
This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CPLLC00(CR)
DEFAULT
Plessey Length Control = Variable Length
Plessey = Fixed Length
Product Reference Guide 169
Enter/Exit Programming Mode
Plessey Set Length 1
This feature specifies one of the bar code lengths for Plessey Length Control
. Length 1 is the minimum label length if in Variable Length
Mode, or the first fixed length if in
Fixed Length Mode. Length includes the bar code’s
data characters only. The length can be set from 01 to 50 characters.
provides some examples for setting Length 1. See
detailed instructions on setting this feature.
Table 24. Plessey Length 1 Setting Examples
2
3
STEP ACTION
1 Desired Setting
EXAMPLES
01 Characters 07 Characters 15 Characters
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT Plessey LENGTH 1 SETTING
4
5
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CPLL1
Select Plessey Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
DEFAULT 01 = Length 1 is 1 Character
CANCEL
170 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Plessey Set Length 2
Mode, or the second fixed length if in
Fixed Length Mode. Length includes the bar
code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
provides examples for setting Length 2. See
for detailed instructions on setting this feature.
Table 25. Plessey Length 2 Setting Examples
STEP
1
2
ACTION
Desired Setting
EXAMPLES
00 (Ignore This
Length)
Scan ENTER/EXIT PROGRAMMING MODE
3
4
5
Scan SELECT PLESSEY LENGTH 2 SETTING
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
07 Characters 15 Characters
‘0’ and ‘7’ ‘1’ and ‘5’
50 Characters
‘5’ AND ‘0’
$CPLL2
Select Plessey Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
DEFAULT 50 = Length 2 is 50 Characters
Product Reference Guide 171
NOTES
172 PowerScan™ PD9530/PBT9500/PM9500
2D SYMBOLOGIES
2D Global Features
2D Maximum Decoding Time on page
2D Structured Append on page 175
2D Normal/Inverse Symbol Control on page 175
The reader supports the following 2D symbologies (bar code types). Sym-
bology-dependent options for each symbology are included in this chapter.
See "1D Symbologies" starting on page 81
for configuration of 1D bar codes.
China Sensible Code on page 179
Postal Code Selection on page 202
2D Global Features
The following features are common to all, or in some cases, most of the available 2D symbologies. Default settings are indicated at each feature/ option with a green arrow. Also reference
for a listing of the most widely used set of standard factory settings. That section also provides space to record any custom settings needed or implemented for your system.
To set most features:
1. Scan the ENTER/EXIT PROGRAMMING bar code at the top of applicable programming pages.
2. Scan the correct bar code to set the desired programming feature or parameter. You may need to cover unused bar codes on the page, and possibly the facing page, to ensure that the reader reads only the bar code you intend to scan.
3. If additional input parameters are needed, go to
and scan the appropriate characters from the keypad.
Additional information about many features can be found in the “References” chapter.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Complete the programming sequence by scanning the ENTER/EXIT PRO-
GRAMMING bar code to exit Programming Mode.
Product Reference Guide 173
Enter/Exit Programming Mode 2D Global Features
2D Maximum Decoding Time
This feature specifies the maximum amount of time the software will spend attempting to decode a 2D label. The selectable range is 10 milliseconds to
2.55 milliseconds.
$CDETM0A(CR)
2D Maximum Decoding Time = 100 msec
$CDETM32(CR)
$CDETM23(CR)
2D Maximum Decoding Time = 350 msec
2D Maximum Decoding Time = 200 msec
DEFAULT
$CDETM80(CR)
2D Maximum Decoding Time = 500 msec
$CDETM16(CR)
2D Maximum Decoding Time = 1 Second
$CDETMC8(CR)
2D Maximum Decoding Time = 2 Seconds
$CDETMFF(CR)
2D Maximum Decoding Time = 2.55 Seconds
174 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
2D Structured Append
Enables/disables ability of reader to append multiple 2D Codes labels in a structured format. The structured append property is globally applied to the following symbologies, if these are enabled:
• Data Matrix
• Aztec
• QR Code
• PDF 417
DEFAULT
$CDESA00(CR)
Structured Append = Disable
$CDESA01(CR)
Structured Append = Enable
$CIPNR01(CR)
2D Normal/Inverse Symbol Control
Specifies the options available for decoding normal/negative printed 2D symbols. This configuration item applies globally to all the 2D symbologies that support that feature according to Standard AIM Specification: Data
Matrix, QR, MicroQR, Aztec and Chinese Sensible Code.
To decode all symbologies, including linear symbologies, refer to " Decode
Negative Image" on page 78 D Symbology Selection
$CIPNR00(CR)
Normal/Inverse Symbol Control = Normal
Normal/Inverse Symbol Control = Inverse
DEFAULT
Product Reference Guide
$CIPNR02(CR)
Normal/Inverse Symbol Control =
Both Normal and Inverse
175
Enter/Exit Programming Mode 2D Global Features
AZTEC CODE
Aztec Code Enable / Disable
Enables/disables the ability of the reader to decode Aztec Code labels.
$CAZEN00(CR)
DEFAULT
Aztec Code = Disable
$CAZEN01(CR)
Aztec Code = Enable
$CAZLC01(CR)
Aztec Code Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CAZLC00(CR)
DEFAULT
Aztec Code Length Control = Variable Length
Aztec Code Length Control = Fixed Length
176 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
Aztec Code Set Length 1
Specifies one of the bar code lengths for
. Length
1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CAZL1
Select Aztec Code Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 0001 = Length 1 is 1 Character
Product Reference Guide 177
Enter/Exit Programming Mode 2D Global Features
Aztec Code Set Length 2
This feature specifies one of the bar code lengths for Aztec Code Length
. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CAZL2
Select Aztec Code Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT Length 2 is 3,832 Characters
178 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
CHINA SENSIBLE CODE
China Sensible Code Enable / Disable
Enables/disables the ability of the reader to decode China Sensible Code labels.
$CCSEN00(CR)
DEFAULT
China Sensible Code = Disable
$CCSEN01(CR)
China Sensible Code = Enable
$CCSLC01(CR)
China Sensible Code Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CCSLC00(CR)
DEFAULT
China Sensible Code Length Control = Variable Length
China Sensible Code Length Control = Fixed Length
Product Reference Guide 179
Enter/Exit Programming Mode 2D Global Features
China Sensible Code Set Length 1
Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CCSL1
Select China Sensible Code Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 0001 = Length 1 is 1 Character
180 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
China Sensible Code Set Length 2
This feature specifies one of the bar code lengths for China Sensible Code
Length Control . Length 2 is the maximum label length if in Variable Length
Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CCSL2
Select China Sensible Code Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT Length 2 is 7,827 Characters
Product Reference Guide 181
Enter/Exit Programming Mode 2D Global Features
DATA MATRIX
Data Matrix Enable / Disable
Enables/disables ability of reader to decode Data Matrix labels.
$CDMEN00(CR)
$CDMEN01(CR)
Data Matrix = Disable
DEFAULT
Data Matrix = Enable
Data Matrix Square/Rectangular Style
Specifies the options available when reading Data Matrix with different form factors. Choices are:
• Square Style
• Rectangular Style
• Both Square and Rectangular Style
The configuration item can also be configured as a bit mask to filter one or more Data Matrix labels with different symbol size AND shape styles.
$CDMDM3FFF0BDF)
Data Matrix Dimensions Mask = Square Style
$CDMDM0000420
Data Matrix Dimensions Mask = Rectangular Style
DEFAULT
$CDMD03FFFFFF
Data Matrix Dimensions Mask =
Both Square and Rectangular Style
182 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
Data Matrix DPM Decoding Safety
This feature defines the tolerance of DPM decoding software to operate with poor quality labels. Decoding Safety is used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. Higher tolerance to poor quality labels increases the reading capability of the scanner.
for more information on this feature.
This feature is valid for the PD9530-DPM model only.
DEFAULT
$CDMDA02(CR)
Data Matrix Decoding Safety = 2
$CDMDA01(CR)
Data Matrix Decoding Safety = 1 (Aggressive)
$CDMDA03(CR)
Data Matrix Decoding Safety = 3
$CDMDA04(CR)
Data Matrix Decoding Safety = 4
$CDMDA05(CR)
Data Matrix Decoding Safety = 5 (Conservative)
Product Reference Guide 183
Enter/Exit Programming Mode 2D Global Features
Data Matrix Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CDMLC00(CR)
DEFAULT
Data Matrix Length Control = Variable Length
$CDMLC01(CR)
Data Matrix Length Control = Fixed Length
Data Matrix Set Length 1
Specifies one of the bar code lengths for
. Length
1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CDML1
Select Data Matrix Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 0001 = Length 1 is 1 Character
184 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
Data Matrix Set Length 2
This feature specifies one of the bar code lengths for Data Matrix Length
. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CDML2
Select Data Matrix Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
senting your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT Length 2 is 3,116 Characters
Product Reference Guide 185
Enter/Exit Programming Mode 2D Global Features
MAXICODE
Maxicode Enable / Disable
Enables/disables ability of reader to decode Maxicode labels.
$CMXEN00(CR)
DEFAULT
Maxicode = Disable
$CMXEN01(CR)
Maxicode = Enable
$CMXPT01(CR)
Maxicode Primary Message Transmission
Enables/disables the transmission of only the Primary Message when the
Secondary Message is not readable.
$CMXPT00(CR)
DEFAULT
Maxicode Primary Message Transmission = Disable
Maxicode Primary Message Transmission = Enable
186 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
Maxicode Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CMXLC00(CR)
DEFAULT
Maxicode Length Control = Variable Length
$CMXLC01(CR)
Maxicode Length Control = Fixed Length
Maxicode Set Length 1
Specifies one of the bar code lengths for Maxicode Length Control
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0145 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CMXL1
Select Maxicode Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
senting your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 0001 = Length 1 is 1 Character
Product Reference Guide 187
Enter/Exit Programming Mode 2D Global Features
Maxicode Set Length 2
second fixed length if in Fixed Length Mode. Characters can be set from
0001 to 0145 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CMXL2
Select Maxicode Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT Length 2 is 0145 Characters
188 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
PDF417
PDF417 Enable / Disable
Enables/disables the ability of the reader to decode PDF417 labels.
$CP4EN00(CR)
$CP4EN01(CR)
PDF417 = Disable
DEFAULT
PDF417 = Enable
$CP4LC01(CR)
PDF417 Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CP4LC00(CR)
DEFAULT
PDF417 Length Control = Variable Length
PDF417 Length Control = Fixed Length
Product Reference Guide 189
Enter/Exit Programming Mode 2D Global Features
PDF417 Set Length 1
Specifies one of the bar code lengths for
PDF417 Length Control . Length 1 is
the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. Characters can be set from 0001 to 2,710 characters (pad with zeroes) in increments of 01. Any value greater than 2,710 will be considered to be 2,710.
for detailed instructions on setting this feature.
$CP4L1
Select PDF417 Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 0001 = Length 1 is 1 Character
190 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
PDF417 Set Length 2
the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Characters can be set from 01 to 2,710 characters (pad with zeroes) in increments of 01. Any value greater than 2,710 will be considered to be 2,710.
for detailed instructions on setting this feature.
$CP4L2
Select PDF417 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT Length 2 is 2,710 Characters
Product Reference Guide 191
Enter/Exit Programming Mode 2D Global Features
MICRO PDF417
Micro PDF417 Enable / Disable
Enables/disables the ability of the reader to decode Micro PDF417 labels .
$CMIEN00(CR)
DEFAULT
Micro PDF417 = Disable
$CMIEN01(CR)
Micro PDF417 = Enable
$CMIU801(CR)
Micro PDF417 Code 128 GS1-128 Emulation
Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or
GS1-128 emulation.
Emulation choices are:
• Micro PDF AIM ID and label type
• Code 128 / EAN128 AIM Id and label type
$CMIU800(CR)
DEFAULT
Micro PDF417 Code 128 GS1-128 Emulation =
Micro PDF AIM ID and label type
Micro PDF417 Code 128 GS1-128 Emulation =
Code 128 / EAN128 AIM ID and label type
192 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
Micro PDF417 Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CMILC00(CR)
DEFAULT
Micro PDF417 Length Control = Variable Length
$CMILC01(CR)
Micro PDF417 Length Control = Fixed Length
$CMIL1
Micro PDF417 Set Length 1
Specifies one of the bar code lengths for Micro PDF417 Length Control .
Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. Characters can be set from 0001 to 0366 characters (pad with zeroes) in increments of 01. Any value greater than 0366 will be considered to be 0366.
for detailed instructions on setting this feature.
Select Micro PDF417 Length 1 Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 0001 = Length 1 is 1 Character
Product Reference Guide 193
Enter/Exit Programming Mode 2D Global Features
Micro PDF417 Set Length 2
This feature specifies one of the bar code lengths for Micro PDF417 Length
. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length includes the bar code’s data characters only. Characters can be set from 0001 to 0366 characters (pad with zeroes) in increments of 01. Any value greater than 0366 will be considered to be 0366.
for detailed instructions on setting this feature.
$CMIL2
Select Micro PDF417 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT Length 2 is 0366 Characters
194 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
QR CODE
QR Code Enable / Disable
Enables/disables the ability of the reader to decode QR Code labels .
$CQREN00(CR)
$CQREN01(CR)
QR Code = Disable
DEFAULT
QR Code = Enable
$CQRLC01(CR)
QR Code Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CQRLC00(CR)
DEFAULT
QR Code Length Control = Variable Length
QR Code Length Control = Fixed Length
Product Reference Guide 195
Enter/Exit Programming Mode 2D Global Features
QR Code Set Length 1
Specifies one of the bar code lengths for QR Code Length Control . Length 1
is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CQRL1
Select QR Code Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 0001 = Length 1 is 1 Character
196 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
QR Code Set Length 2
the second fixed length if in Fixed Length Mode. Characters can be set from
0001 to 7,089 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CQRL2
Select QR Code Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanu-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT Length 2 is 7,089 Characters
MQEN01
MICRO QR CODE
Micro QR Code Enable/Disable
Enables/disables the ability of the reader to decode Micro QR Code labels .
MQEN00
DEFAULT
Micro QR Code = Disable
Micro QR Code = Enable
Product Reference Guide 197
Enter/Exit Programming Mode 2D Global Features
Micro QR Code Length Control
This feature specifies either variable length decoding or fixed length decoding for this symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CMQLC00(CR)
DEFAULT
Micro QR Code Length Control = Variable Length
$CMQLC01(CR)
Micro QR Code Length Control = Fixed Length
Micro QR Code Set Length 1
Specifies one of the bar code lengths for Micro QR Code Length Control.
Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to
0035 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CMQL1
Select Micro QR Code Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 0001 = Length 1 is 1 Character
198 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
Micro QR Code Set Length 2
This feature specifies one of the bar code lengths for Micro QR Code Length
Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0035 characters in increments of 0001 (pad with zeroes).
for detailed instructions on setting this feature.
$CMQL2
Select QR Code Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
senting your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT Length 2 is 0035 Characters
Product Reference Guide 199
Enter/Exit Programming Mode 2D Global Features
UCC COMPOSITE
UCC Composite Enable / Disable
Enables/disables the ability of the reader to decode the stacked part of a
UCC Composite label.
This feature is not effective when Global AIM IDs are enabled (see
).
DEFAULT
$CCMEN01(CR)
UCC Composite = Enable
$CCMEN00(CR)
UCC Composite = Disable
200 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features Enter/Exit Programming Mode
UCC Optional Composite Timer
Specifies the amount of time the system will wait for the stacked part of a
UCC Composite label before transmitting the linear label without an addon.
$CCMOT00(CR)
DEFAULT
UCC Optional Composite Timer = Timer Disabled
$CCMOT01(CR)
UCC Optional Composite Timer = 100msec
$CCMOT02(CR)
UCC Optional Composite Timer = 200msec
$CCMOT03(CR)
UCC Optional Composite Timer = 300msec
$CCMOT04(CR)
UCC Optional Composite Timer = 400msec
$CCMOT05(CR)
UCC Optional Composite Timer = 500msec
Product Reference Guide 201
Enter/Exit Programming Mode 2D Global Features
POSTAL CODE SELECTION
Enables/disables the ability of the scanner to decode labels of a specific postal symbology.
$CPOEN00(CR)
DEFAULT
Postal Code Selection = Disable All Postal Codes
$CPOEN01(CR)
Postal Code Selection = Enable Postnet
$CPOEN02(CR)
Postal Code Selection = Enable Planet
$CPOEN03(CR)
Postal Code Selection = Enable Royal Mail
$CPOEN04(CR)
Postal Code Selection = Enable Kix
$CPOEN05(CR)
Postal Code Selection = Enable Australia Post
202 PowerScan™ PD9530/PBT9500/PM9500
2D Global Features
Postal Code Selection (continued)
Enter/Exit Programming Mode
$CPOEN06(CR)
Postal Code Selection = Enable Japan Post
$CPOEN07(CR)
Postal Code Selection = Enable IMB
$CPOEN08(CR)
Postal Code Selection = Enable Sweden Post
$CPOEN09(CR)
Postal Code Selection = Enable Portugal Post
$CPOBB01(CR)
Postnet BB Control
Controls the ability of the scanner to decode B and B' fields of Postnet labels.
$CPOBB00(CR)
DEFAULT
Postnet BB Control = Disable
Postnet BB Control = Enable
Product Reference Guide 203
NOTES
204 PowerScan™ PD9530/PBT9500/PM9500
MOTION FEATURES
Use this chapter to configure motion settings for the handheld.
Reference
Appendix C, for a listing of standard factory settings.
Motion Aiming Control
Configures the ability of the scanner to Enable/Disable the Aiming system when motion is detected.
$CMOMD00(CR)
$CMOMD01(CR)
Motion Aiming Control = Enable
Motion Aiming Control = Disable
DEFAULT
Product Reference Guide 205
Enter/Exit Programming Mode
Motion Sensitivity
Defines discrete set of levels for scanner motion sensitivity when in handheld use.
$CMOSY00(CR)
$CMOSY01(CR)
Motion Sensitivity = Medium
Motion Sensitivity = Low
DEFAULT
$CMOSY02(CR)
Motion Sensitivity = High
$CMOTO
Motionless Timeout
Specifies the waiting time in 100 millisecond ticks to assume that the reader is in a motionless condition. The selectable range is 500 msec to 25.5 Seconds. When no motion event is detected for a period of time longer than this timeout, the software assumes the reader is in a motionless condition. This option relates to such features as Aimer On and Stand Mode Object Sense
scanning with respect to motion. See " Motionless Timeout" on page 287 in
References.
Select Motionless Timeout Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by three digits from the Alpha-
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 020 = Motionless Timeout = 2 seconds
206 PowerScan™ PD9530/PBT9500/PM9500
WIRELESS FEATURES
This section provides options and programming related to the reader’s wireless communication features. Reference
for a listing of standard factory settings.
Good Transmission Beep" on page 209
•
Automatic Configuration Update on page 214
•
Copy Configuration to Scanner on page 214
•
Copy Configuration to Base Station on page 214
•
•
•
Erase Batch Memory on page 216
•
RF Batch Mode Transmit Delay on page 216
•
Source Radio Address Transmission on page 217
•
Source Radio Address Delimiter Character on page 218
R EAL T IME C LOCK (RTC) C ONFIGURATION
•
•
•
•
•
•
Date-Time Separator on page 221
Date-Time Transmission Order on page 222
PBT9500-Only Features
B LUETOOTH S ECURITY F EATURES
•
Bluetooth Security Mode on page 224
•
Bluetooth PIN Code on page 224
•
Select PIN Code Length on page 224
•
Product Reference Guide 207
Enter/Exit Programming Mode
PBT9500-Only Features (continued)
•
Bluetooth Poll Rate on page 226
•
•
•
Bluetooth HID Variable PIN Code on page 228
•
Bluetooth HID Alt Mode on page 229
•
Bluetooth HID Send Unknown ASCII Char on page 229
•
Bluetooth Max Client on page 230
•
Bluetooth Friendly Name on page 231
•
Bluetooth Reconnect Attempt Mode on page 231
•
PM9500-Only Features
•
STAR Radio Protocol Timeout on page 235
•
STAR Radio Transmit Mode on page 236
•
Changing System Speed on page 237
C OMPATIBILITY WITH PM8500 starting on page 238
•
Compatibility mode on page 238
•
Changing from Normal to Compatible Mode on page 238
•
•
Changing from Compatible Mode back to Normal on page
Base Address Stamping on page 240
•
Base Address Delimiter Character on page 240
•
RS-485 Master Header/Terminator ( Prefix/Suffix) on page
•
RS-485 Cradle Address on page 241
•
RS-485 Slave Minimum Address on page 242
•
RS-485 Slave Maximum Address on page 242
•
RS-485 Network Working Mode on page 243
•
RS-485 Network Warning Message on page 243
•
RS-485 Transmission Warning Message on page 244
•
RS-485 Network Baud Rate on page 244
Display and Keyboard Features
•
Display Operating Mode on page 245
•
Display Off Timeout on page 246
•
•
•
•
Enable/disable buttons on page 248
•
Action Configuration for Function Keys on page 250
•
•
•
•
Set String Terminator on page 253
208 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
WIRELESS BEEPER FEATURES
Several options are available to configure beeper behavior for RF operation.
Good Transmission Beep
Enables/disables the Good Transmission Beep indication. When enabled, a beep occurs when a Label is correctly transmitted to the base.
$CBTAB00(CR)
Good Transmission Beep = Disable
$CBTAB01(CR)
Good Transmission Beep = Enable
DEFAULT
Beep Frequency
Adjusts radio-specific beep indications to sound at a low, medium or high frequency, selectable from the list below (controls the beeper’s pitch/tone).
$CBTBF00(CR)
DEFAULT
Beep Frequency = Low
$CBTBF01(CR)
Beep Frequency = Medium
$CBTBF02(CR)
Beep Frequency = High
Product Reference Guide 209
Enter/Exit Programming Mode
Beep Duration
This feature controls the duration of radio-specific beep indications .
$CBTBD06(CR)
Beep Duration = 60 msec
$CBTBD08(CR)
DEFAULT
Beep Duration = 80 msec
$CBTBD0A(CR)
Beep Duration = 100 msec
$CBTBD0C(CR)
Beep Duration = 120 msec
$CBTBD0E(CR)
Beep Duration = 140 msec
$CBTBD10(CR)
Beep Duration = 160 msec
$CBTBD12(CR)
Beep Duration = 180 msec
$CBTBD14(CR)
Beep Duration = 200 msec
210 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Beep Volume
Selects the beeper volume (loudness) of radio-specific beep indications.
There are three selectable volume levels.
$CBTBV00(CR)
Beep Volume = Low
$CBTBV01(CR)
Beep Volume = Medium
$CBTBV02(CR)
DEFAULT
Beep Volume = High
Disconnect Beep
Enables/disables the beep indication that a handheld has become connected or disconnected from a Base Station.
The defaults are different for the STAR and Bluetooth models.
$CBTDB01(CR)
Disconnect Beep = Enable
$CBTDB00(CR)
Disconnect Beep = Disable
DEFAULT
Product Reference Guide 211
Enter/Exit Programming Mode
Docking Beep
Enables/disables a beep indication when the handheld is placed in the Base
Station.
$CBTCB00(CR)
Docking Beep = Disable
$CBTCB01(CR)
DEFAULT
Docking Beep = Enable
Leash Alarm
This setting specifies the number of seconds to sound the Leash Mode beeps (three per second) when the handheld goes out of range. This is especially useful in instances where the reader might inadvertently have been placed in a bag or cart.
For this mode to be effective, the reader must be linked to the Base Station.
If the reader is asleep or disconnected from the Base Station, there is no way for it to know where it is relative to the Base Station because communication is not active between the devices.
$CBTLB00(CR)
DEFAULT
Leash Alarm = Disabled
$CBTLB01(CR)
Leash Alarm = 1 Second
$CBTLB02(CR)
Leash Alarm = 2 Seconds
212 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Leash Alarm (continued)
$CBTLB03(CR)
Leash Alarm = 3 Seconds
$CBTLB04(CR)
Leash Alarm = 4 Seconds
$CBTLB05(CR)
Leash Alarm = 5 Seconds
$CBTLB19(CR)
Leash Alarm = 25 Seconds
$CBTLB0A(CR)
Leash Alarm = 10 Seconds
$CBTLB1E(CR)
Leash Alarm = 30 Seconds
Product Reference Guide 213
Enter/Exit Programming Mode
CONFIGURATION UPDATES
See page 288 in “References” for detailed information and examples of these
features.
Automatic Configuration Update
When this feature is enabled, a reader and its linked Base Station can automatically ensure they stay in sync with regard to application hardware and/ or configuration. See
for more information on this feature.
$CBTCU00(CR)
$CCpyCfg2HH
Automatic Configuration Update = Disable
$CBTCU01(CR)
DEFAULT
Automatic Configuration Update = Enable
Copy Configuration to Scanner
Scan the following label to copy the current Base Station configuration to the scanner. Use this method when the Auto Configuration Update feature is disabled and you want a one-time configuration update to be performed on the scanner.
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this bar code.
CpyCfg2HH
Copy Configuration to Scanner
Copy Configuration to Base Station
Scan the following label to copy the current scanner configuration to the
Base Station. Use this method when the Auto Configuration Update feature is disabled and you want a one-time configuration update to be performed on the Base Station.
Cpycfg2Ba
Copy Configuration to Base Station
Do not scan an ENTER/EXIT PROGRAMMING MODE label with this bar code.
214 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
BATCH FEATURES
Batch Mode
This option specifies whether to store labels in the handheld while disconnected from the base. Options are as follows:
• Disabled — The handheld will not store/batch labels.
• Automatic — The handheld will store labels to RAM when the handheld goes out of range and is disconnected from the remote device.
• Manual — The handheld will always store labels to Flash memory. The user must manually send the stored labels to the remote device using a special "batch send" label.
$CBTBM00(CR)
DEFAULT
Batch Mode = Disabled
$CBTBM01(CR)
Batch Mode = Automatic
$CBTBM02(CR)
Batch Mode = Manual
Send Batch
When the scanner is configured in Manual Batch Mode, use the following bar code to initiate sending of labels stored in batch memory.
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this bar code.
BatchSend
Send Batch
Product Reference Guide 215
Enter/Exit Programming Mode
Erase Batch Memory
When the scanner is configured in Manual Batch Mode, use the following bar code to erase any labels stored in batch memory.
Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this bar code.
BatchClear
Erase Batch Memory
RF Batch Mode Transmit Delay
Specifies the delay in 10 msec increments between transmitting labels stored in batch memory.
$CBTTD00(CR)
DEFAULT
RF Batch Mode Transmit Delay = No Delay
$CBTTD05(CR)
RF Batch Mode Transmit Delay = 50 mS
$CBTTD0A(CR)
RF Batch Mode Transmit Delay = 100 mS
$CBTTD32(CR)
RF Batch Mode Transmit Delay = 0.5 seconds
$CBTTD64(CR)
RF Batch Mode Transmit Delay = 1 second
$CBTTDFA(CR)
RF Batch Mode Transmit Delay = 2.5 seconds
216 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
DIRECT RADIO AUTOLINK
This feature enables/disables the ability to link a wireless handheld to a base station without scanning the Unlink label first.
$CBTDL00(CR)
DEFAULT
Direct Radio Link = Unlink Label Required
$CBTDL01(CR)
Direct Radio Link = Automatic Unlinking
RF ADDRESS STAMPING
These features allow configuration of source radio data inclusion.
Source Radio Address Transmission
Enables/disables the ability of source radio address information to be transmitted to the host and, if so, at what position with respect to the label data. See
page 288 in “References” for detailed information and examples
for setting this feature.
When included as a prefix, the source-radio ID is displayed after all label formatting has been applied. The 6 byte hex address is sent as
12 ascii characters, i.e., an address of 00 06 66 00 1A ED will be sent as
(shown in hex): 30 30 30 36 36 36 30 30 31 41 45 44
$CBTAS00(CR)
DEFAULT
Source Radio Address Transmission = Do Not Include
$CBTAS01(CR)
Source Radio Address Transmission = Prefix
Product Reference Guide 217
Enter/Exit Programming Mode
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and radio address when address stamping is enabled.
"Source Radio Address Transmission" on page 217 is enabled.
$CBTAD
Set Source Radio Address Delimiter Character
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 00 = No Delimiter Character
218 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
REAL TIME CLOCK (RTC) CONFIGURATION
Current Date
Sets the date of the internal Real Time Clock (RTC)
$CDYMD
Set Current Date = YYMMDD
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
Current Time
Sets the time of the internal Real Time Clock (RTC). HH = 24 hours format
$CTHMS
Set Current Time = HHMMSS
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
Product Reference Guide 219
Enter/Exit Programming Mode
Date Tx Format
Sets the format of the date.
DEFAULT
$CDTXF01\r
YYYYMMDD (No ISO)
$CDTXF00\r
YYYY-MM-DD (ISO 8601)
$CDTXF02\r
MMDDYYYY
$CDTXF03\r
DDMMYYYY
Time Tx Format
Sets the format of the time.
DEFAULT
$CTTXF01\r hhmmss (No ISO)
$CTTXF00\r hh:mm:ss (ISO 8601)
220 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Date-Time Separator
Sets the character used to separate Date and Time from the next field in message.
$CRFTD0000\r
DEFAULT
$CRFTD01\r
Set Character Separator =
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Disable Date-Time Separator
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by 2 digits from the Alphanumeric characters
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
Product Reference Guide 221
Enter/Exit Programming Mode
Date-Time Transmission Order
Allows the selection of the order of date and time transmission.
$CRFTS00\r
DEFAULT
Disabled
$CRFTS01\r
ISO 8601: Date'T'Time
$CRFTS02\r
DateTime
$CRFTS03\r
TimeDate
$CRFTS04\r
Date
$CRFTS05\r
Time
222 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
PBT9500-ONLY FEATURES
The features in this section are valid only for PBT9500 Bluetooth models.
Also reference the Setup section for instructions on
BLUETOOTH SECURITY FEATURES
On the Bluetooth system, it is possible to set a (configurable) PIN code to authenticate/connect Bluetooth devices, and encrypt the data.
The Bluetooth PIN code can be enabled and configured by reading the bar codes in the following sections.
If you are using a Bluetooth scanner directly connected to a host through a
Bluetooth dongle, verify that the scanner and the Bluetooth driver used by the dongle share the same PIN code and the same security level. Otherwise the connection cannot be established.
Follow these steps to set the PIN code for a scanner:
1.
Enable Bluetooth Security Mode by scanning the “Enable” bar code
below.
2.
Select a PIN code length of either 4 or 16 characters by scanning the appropriate bar code in
"Select PIN Code Length" on page 224.
3. Scan the relevant bar code from
"Set PIN Code" on page 225, then scan
the desired alphanumeric characters from the keypad in
to set the PIN code.
in “References” for more detailed information and examples for this feature.
Product Reference Guide 223
Enter/Exit Programming Mode
Bluetooth Security Mode
This feature enables/disables authentication and encryption of the Bluetooth link. Use the feature
"Bluetooth PIN Code" on page 224 to specify the
length and digits in the PIN code used to authenticate the Bluetooth Link.
Changing the security mode setting will unlink the devices. If the Automatic
Configuration Update is set to the default “Enabled” setting, the devices must only be relinked. If the Automatic Configuration Update is set to “Disabled,” the Security Mode setting must also be updated in the Base Station using
Aladdin. After the Base Station has been updated, the devices must be relinked.
$CBTSE00(CR)
DEFAULT
Bluetooth Security Mode = Disable
$CBTSE01(CR)
Bluetooth Security Mode = Enable
Bluetooth PIN Code
After enabling Security Mode (see
"Bluetooth Security Mode" on page 224
), specify whether you want to set a 4-digit or a 16-digit PIN Code. See
page 290 for detailed information and examples for setting this feature.
Select PIN Code Length
$CBTPS00\r
Select 4-character Bluetooth PIN Code
DEFAULT
~$CBTPS01\r
Select 16-character Bluetooth PIN Code
224 PowerScan™ PD9530/PBT9500/PM9500
~
Enter/Exit Programming Mode
$CBTPC
Set PIN Code
Determine the desired characters for the PIN code, then convert to hexadecimal using the
on the inside back cover of this manual.
for detailed information and examples for setting this feature.
Set 4-character Bluetooth PIN Code
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by the hexadecimal digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
$CBTP6
Set 16-character Bluetooth PIN Code
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT 31323334 = Default PIN Code is 1234
Product Reference Guide 225
Enter/Exit Programming Mode
OTHER BLUETOOTH FEATURES
Bluetooth Poll Rate
This feature specifies the time between Bluetooth polls.
$CBTST00(CR)
Bluetooth Poll Rate = Maximum Bluetooth Poll Rate
$CBTST01(CR)
Bluetooth Poll Rate = 10 ms
$CBTST02(CR)
Bluetooth Poll Rate = 20 ms
DEFAULT
$CBTST05(CR)
Bluetooth Poll Rate = 50 ms
$CBTST0A(CR)
Bluetooth Poll Rate = 100 ms
$CBTST14(CR)
Bluetooth Poll Rate = 200 ms
226 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Power Off
for information about this Bluetooth feature.
Powerdown Timeout
The Powerdown Timeout feature sets the time for automatically switching the unit off when the imager has been idle.
$CSLPS00(CR)
Powerdown Timeout = Disable
$CSLPS01(CR)
Powerdown Timeout = 10 minutes
$CSLPS02(CR)
Powerdown Timeout = 20 minutes
R)$CSLPS03(CR
)
Powerdown Timeout = 30 minutes
$CSLPS06(CR)
Powerdown Timeout = 60 Minutes (1 Hour)
$CSLPS0C(CR)
Powerdown Timeout = 120 Minutes (2 Hours)
Product Reference Guide 227
Enter/Exit Programming Mode
Bluetooth HID Variable PIN Code
Specifies the selection available for Static or Variable Pin Code, when Bluetooth HID profile is configured.
Some Bluetooth drivers on the Host (such as WIDCOMM and BlueSoleil 8) require a Variable PIN Code. When attempting connection, the application presents a window that includes a PIN Code which is to be input using the
PowerScan BT9500. Scan the bar code "Variable PIN Code" below, then use the host computer’s Bluetooth manager to “Discover new devices” and select
"Datalogic Scanner." Use a text editor to see incoming data on the port designated by the computer's Bluetooth manager.
If you receive an error message, it may be necessary to disable security on the device.
When you hear the beep and see the Green LED blinking indicating the reader is waiting for an alphanumeric entry, enter the required variable PIN
Code by scanning the corresponding bar codes in Appendix D, Keypad
for alphanumeric entry. Finish by scanning the Exit HID Variable PIN Code label.
$CBTHP00
Set Static Pin Code
~
$CBTHP01
Set Variable Pin code
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
Exit HID Variable PIN Code
228 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Bluetooth HID Alt Mode
Enable/Disable the ability to correctly transmit a label to the host regardless of the Bluetooth HID Country Mode selected, when Bluetooth HID Profile is configured.
Read the configuration command label below for the HID Alt Mode feature.
HID Alt Mode = OFF
HID Alt Mode = ON
Bluetooth HID Send Unknown ASCII Char
Unknown characters are characters the host does not recognize. When Disable HID Send ASCII Unknown character is selected, all barcode data is sent except for unknown characters, and an error beep will sound. When sent as a SPACE.
HID
Send Unknown ASCII character is enabled, an unknown character will be
DEFAULT
$CBTHO00(CR
HID Send Unknown ASCII character = Disable
CBTHO01(CR
HID Send Unknown ASCII character = Enable
Product Reference Guide 229
Enter/Exit Programming Mode
Bluetooth Max Client
Set the number of Readers that can connect to the Base in a Piconet network.
$CBTMS01(CR)
Bluetooth Max Client = 1
$CBTMS02(CR)
Bluetooth Max Client = 2
DEFAULT
$CBTMS03(CR)
Bluetooth Max Client = 3
$CBTMS04(CR)
Bluetooth Max Client = 4
$CBTMS05(CR)
Bluetooth Max Client = 5
$CBTMS06(CR)
Bluetooth Max Client = 6
$CBTMS07(CR)
Bluetooth Max Client = 7
230 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Bluetooth Friendly Name
You can set a meaningful name for PowerScan BT9500 that will appear in the application during device discovery.
To set a new Bluetooth Friendly Name, scan the barcode below and follow the instructions.
$CBTFN
Set Bluetooth Friendly Name
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by a maximum 64 digits from
the Alphanumeric characters in
. The digits must be the hexadecimal ASCII
representation of the desired characters. If less than the expected string of 32 characters are selected, scan the ENTER/EXIT bar code to terminate the string.
~
CANCEL
DEFAULT
POWERSCAN BT9500
[SERIAL_NUMBER_SCANNER]
Bluetooth Reconnect Attempt Mode
Enable/Disable reconnection by trigger pull.
$CBTRM00(
Bluetooth Reconnect Attempt Mode = Disable
$CBTRM01(
Bluetooth Reconnect Attempt Mode = Enable
DEFAULT
Product Reference Guide 231
Enter/Exit Programming Mode
HID Country Mode
When the Reader is connected with a Bluetooth Adapter in HID mode, you may want to set the country for which your PC is localized. In order to do that, read one of the configuration command labels below.
Country Mode = U.S.
Country Mode = Belgium
Country Mode = Britain
Country Mode = Croatia
Country Mode = Czech Republic
Country Mode = Denmark
Country Mode = France
232 PowerScan™ PD9530/PBT9500/PM9500
HID COUNTRY MODE (continued)
Enter/Exit Programming Mode
Country Mode = French Canadian
Country Mode = Germany
Country Mode = Hungary
Country Mode = Italy
Country Mode = Japanese 106-key
Country Mode = Lithuanian
Country Mode = Norway
Country Mode = Poland
Product Reference Guide
Country Mode = Portugal
233
Enter/Exit Programming Mode
HID COUNTRY MODE (continued)
Country Mode = Romania
Country Mode = Sweden
Country Mode = Spain
Country Mode = Slovakia
Country Mode = Switzerland
234 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
PM9500-ONLY FEATURES
The features in this section are valid only for the PowerScan PM9500 Star model:
•
STAR Radio Protocol Timeout on page 235
•
STAR Radio Transmit Mode on page 236
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the handheld reader and Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (number of readers in the same area). The selectable range for this feature is from 02 to 25 seconds. See
page 289 in “References” for detailed informa-
tion and examples for setting this feature.
Set Radio Protocol Timeout
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by two digits from the Alpha-
resenting your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
CANCEL
DEFAULT
02 = 2 Seconds Radio Protocol Timeout
Product Reference Guide 235
Enter/Exit Programming Mode
STAR Radio Transmit Mode
Specifies the transmission protocol for Star communications.
Options are:
• ACK from cradle to scanner — signals a good transmission as soon as the Base Station receives a label
• ACK when sent to host — scanner signals a good transmission as soon as the Base Station has sent the label to the host
• ACK from host — scanner signals a good transmission as soon as the
Base Station has sent the label to the host and host has replied with an acknowledge message.
DEFAULT
ACK from cradle
ACK when sent to host
ACK from host
ACK from host works only for RS-232 or USB-COM interfaces with
ACK/NACK disabled. If ACK from host is configured with any other interface conditions, it works like ACK when sent to host. See
"Message Formatting" on page 293 for details.
For this feature to be operational, the scanner must be set to
Ignore Host Commands (see page 23
).
The Base Station can receive a host message only if Host Com-
mands Obey/Ignore (page 23) is set to Ignore.
236 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Changing System Speed
1. Link the PM9500 with a BC9xxx Base.
2. With the PM9500, read a “Compatible Mode/Normal Mode Speed” programming label on
page 238 to set “Low, Medium, or High Speed”.
3. Place the PM9500 into the BC9xxx.
The Reader and Base will now be linked at the new programmed speed.
This feature can also be programmed using Datalogic Aladdin.
1. On the BC9xxx Base, change the Compatible mode parameter to low, intermediate, or high speed through Aladdin.
2. Place an unlinked PM9500 onto the BC9xxx base.
The Reader and base will link at the new programmed speed.
Product Reference Guide 237
Enter/Exit Programming Mode
COMPATIBILITY WITH PM8500
Compatibility mode
Powerscan PM9500 offers a limited set of features compatible with the previous PM8500 family. To access those features, you have to program the system through the Compatible Mode parameter.
When in normal mode, the same parameter can be used to configure the communication speed.
"Restore Custom Defaults" on page 18 when switching from normal mode to compatible mode, or
vice-versa.
Changing from Normal to Compatible Mode
PM9500 Handheld
1. With the PM9500, read the Compatible Mode (0) bar code below.
2. Now you can link your PM9500 with a BC8xxx as if it were a PM8500, assigning an address to the reader and performing a Join or Bind (see the Set Radio Address and Bind commands in the PM8500 QRG).
When the PM9500 is in Compatible Mode, some newer features
(such as communication speed programming) will not be available.
$CSTCP00\r
Compatible Mode (0)
$CSTCP01\r
Normal Mode: Low Speed (1)
$CSTCP02\r
Normal Mode: Intermediate Speed (2)
$CSTCP03\r
Normal Mode: High Speed (3)
DEFAULT
238 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
BC9xxx Base
The BC9xxx can be changed from Normal to Compatible mode using the
Aladdin configuration tool. See
"Datalogic Aladdin™" on page 6 for more
information. This will allow you to Join or Bind a PM8500 to your BC9xxx.
Changing from Compatible Mode back to Normal
PM9500 Handheld
1. With the PM9500, read a Compatible mode programming label on
with a value of “Low, Medium, or High Speed”.
2. With the PM9500, read the Unlink programing label.
3. Now you can link your PM9500 to a BC9xxx in normal mode; the
PM9500 will inherit the programmed speed from the BC9xxx.
BC9xxx Base
1. Using Datalogic Aladdin, change the Compatible Mode parameter to
“Low, Medium, or High Speed”.
2. Now you can link a previously unlinked PM9500; the reader will inherit the speed programmed in the BC9xxx.
If Aladdin is not available, use the following procedure:
1. With a PM9500 in normal mode, read the Unlink programming label on
, then read the following bar code:
Return to Normal
Do not scan an ENTER/EXIT PROGRAMMING MODE label with this bar code.
2. Place the same PM9500 on your BC9xxx.
Your BC9xxx will link to the PM9500 and will inherit the reader’s programmed speed.
Product Reference Guide 239
Enter/Exit Programming Mode
Base Address Stamping
Enables/disables the ability of base address information to be transmitted to the host and, if so, at what position with respect to the label data. See
page 288 in “References” for detailed information and examples for setting
this feature.
$CCNAS00(CR)
DEFAULT
Base Address Transmission = Do Not Include
$CCNAS01(CR)
Base Address Transmission = Prefix
Base Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and base address when address stamping is enabled.
This feature only applies if
"Base Address Stamping" on page 240
is enabled.
$CCNAD
Set Base Address Delimiter Character
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar code at left followed by two digits from the Alphanumeric characters in
representing your desired character. End by scanning the
ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 00 = No Delimiter Character
240 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
RS-485 Master Header/Terminator ( Prefix/Suffix)
Specifies the Master Cradle header or terminator characters to be added to a label sent to Host. The characters may be added as a prefix (in a position before the bar code data, also called a header) and/or as a suffix (in a position following the bar code data, also called a terminator).
To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE bar code above to place the unit in Programming Mode, then the “Set Master
Cradle Prefix” or “Set Master Cradle Suffix” bar code followed by the digits
(in hex) from the Alphanumeric characters in Appendix D, Keypad
representing your desired character(s). If less than the expected string of 8 characters are selected, scan the ENTER/EXIT bar code to terminate the string.
Exit programming mode by scanning the ENTER/EXIT bar code again.
$CR4A0
Set Master Cradle Prefix
$CR4A1
Set Master Cradle Suffix
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
$CS1AD
RS-485 Cradle Address
Specifies the Address for the Cradle in the RS-485 network.
.
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE bar code above, then the bar code at left followed by the digits from the Alphanumeric characters in
representing your desired char-
acter(s). End by scanning the ENTER/EXIT bar code again.
Set Cradle Address
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
Product Reference Guide 241
Enter/Exit Programming Mode
RS-485 Slave Minimum Address
Specifies the minimum address that can be set for a Cradle in an RS-485 network.
The maximum number of cradles in a single network is 16 (including the Master if present). All cradles in the system must have different addresses.
$CR4JB
Slave Minimum Address
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE bar code above, then the bar code at left followed by four digits from the Alphanumeric characters in
representing your desired char-
acter(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
RS-485 Slave Maximum Address
Specifies the maximum address that can be set for a Cradle in an RS-485 network.
The maximum number of cradles in a single network is 16 (including the Master if present). All cradles in the system must have different addresses.
$CR4JC
Slave Maximum Address
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT PROGRAM-
MING MODE bar code above, then the bar code at left followed by four digits from the Alphanumeric characters in
representing your desired char-
acter(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
242 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
RS-485 Network Working Mode
Specifies the selection available for Cradle working mode in an RS-485 network.
$CR4RZ00\r
DEFAULT
Disable Network
$CR4RZ01\r
Enable RS-485 Slave
$CR4RZ02\r
Enable RS-485 Master
RS-485 Network Warning Message
Enable/Disable the ability of Cradle to transmit warning messages to the
Host regarding some RS-485 network errors.
$CR4JG00\r
DEFAULT
Not Transmitted
$CR4JG01\r
Transmitted
Product Reference Guide 243
Enter/Exit Programming Mode
RS-485 Transmission Warning Message
Enable/Disable the ability of the cradle to transmit warning messages to the Host regarding wrong reception of data.
$CR4JH00\r
DEFAULT
Not Transmitted
$CR4JH01\r
Transmitted
RS-485 Network Baud Rate
Specifies the baud rate of an RS-485 network.
$CR4JE00\r
DEFAULT
Baud Rate 9600
$CR4JE01\r
Baud Rate 19200
$CR4JE02\r
Baud Rate 34800
244 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
DISPLAY AND KEYBOARD FEATURES
Display Operating Mode
Select the operating mode of the display. Options are:
•
•
•
Normal Mode:
Local Echo
Display not cleared, no echo of the code on Display.
: Display cleared after decode, echo of the code on display.
Clear display after decode : Display is cleared after decode, no echo.
$CDIMD00\r
Normal Mode = Display not cleared
$CDIMD01\r
Local echo mode
DEFAULT
$CDIMD02\r
Clear display after decode
Product Reference Guide 245
Enter/Exit Programming Mode
Display Off Timeout
Sets the timeout for display, backlight and keyboard.
$CDIOT
Set Display Off Timeout
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Display Off Timeout = Disabled
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by two digits from the Alphanumeric characters in
representing your desired character(s). End by scanning the ENTER/EXIT bar code again.
~
CANCEL
DEFAULT 08 = 8 second delay
246
Backlight Enable
Enables/Disables the display backlight.
$CDIBL00\r
DEFAULT
Backlight Disabled
$CDIBL01\r
Backlight Enabled
PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
Display Contrast
Adjust the contrast of the display.
$CDICT
Set Display Contrast
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by two digits numeric characters in
(00-32 by 01) from t he Alpha-
representing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
~
CANCEL
Font Size
Select the font size.
DEFAULT
$CDIFS01\r
Font Size = Medium
$CDIFS00\r
Font Size = Small
$CDIFS02\r
Font Size = Large
Product Reference Guide 247
Enter/Exit Programming Mode
Enable/disable buttons
This feature offers the ability to enable or disable each key independently.
Figure 6. PowerScan 9500 Keypad
$CPWFZF000\r
Key Programming
.
DEFAULT
All 4 keys enabled
$CPWFZ0000\r
$CPWFZ
Enable a combination of the 4 keys
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
All 4 keys disabled
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by 4 digits from the Alphanumeric
The last 3 digits must always be 0; the 4 bits of the first digit must be 1 if the corresponding key is enabled; the four bits represent, starting from the highest: Arrow Up, F2, F1, Arrow Down. End by scanning the ENTER/EXIT bar code again.
~
CANCEL
248 PowerScan™ PD9530/PBT9500/PM9500
6
7
4
5
1
2
3
A
B
8
9
C
CMD_ID Name Function
Enter/Exit Programming Mode
CONFIGURE ACTIONS FOR FUNCTION KEYS
Each of the function keys can be programmed to perform a user-assigned function. This is done by associating a function key with either a predefined
command or your own custom string. See the " Define Strings" on page
command to define customized strings.
Each function key has an associated label which shows in the display when active. The default labels are shown in the table below. To program the
function key labels, see " Set String ID" on page 252 .
The following table shows the list of predefined commands and available strings.
Table 26. Keyboard Programming
Default
Label
No configured action.
0 Not configured
Enter CMD
String 1
String 2
String 3
String 4
String 5
Backlight CMD
Clear CMD
If a key must be kept enabled but in normal mode isn’t required, this function can be selected to keep it inactive.
Whenever an unconfigured function key is pressed, an error message appears on display and an error beep is emitted.
Same as ENTER_KEY.
Display and transmit string 1.
Display and transmit string 2.
Display and transmit string 3.
Display and transmit string 4.
Display and transmit string 5.
Toggle backlight on/off.
Clears the screen
Reserved for future use
Reserved for future use
Show Date/Time Display the internal date, time.
Reserved for future use
<None>
S3T
S4T
S5T
Blt
CLR
Ent
S1T
S2T
Tim
Product Reference Guide 249
Enter/Exit Programming Mode
Action Configuration for Function Keys
Configure actions (up to three) for the function keys
Configure Actions for F1
$CPWEV0000\r
DEFAULT
$CPWEV
Configures Action for F1
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
F1 No Actions Configured
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code for the Function Key you want to program. Next scan
4 digits from the Alphanumeric characters in
.
The first digit must be 0; the following 3 digits must be configured according to the CMD_ID numbers in
Table 26 on page 249
. End by scanning the
ENTER/EXIT bar code again.
~
CANCEL
Configure Actions for F2
$CPWET0000\r
DEFAULT
$CPWET
Configure Actions for F2
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
F2 No Actions Configured
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code for the Function Key you want to program. Next scan
4 digits from the Alphanumeric characters in
.
The first digit must be 0; the following 3 digits must be configured according to the CMD_ID numbers in
Table 26 on page 249
. End by scanning the
ENTER/EXIT bar code again.
~
CANCEL
250 PowerScan™ PD9530/PBT9500/PM9500
$CPWEP
Enter/Exit Programming Mode
Define Strings
Configure string 1-5.
To configure this feature, scan the ENTER/EXIT PROGRAMMING MODE bar code at the top of the page, then the bar code for the String you want to set. Define the label string by scanning 32 digits from the Alphanumeric characters in
.
The digits must be the hexadecimal ASCII representation of the desired characters; if less than the expected string of 16 characters are selected, scan the ENTER/EXIT bar code to terminate the string.
End by scanning the ENTER/EXIT bar code again.
Set String 1
$CPWEO
Set String 2
$CPWEN
Set String 3
$CPWEM
Set String 4
$CPWEL
Set String 5
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
~
CANCEL
Product Reference Guide 251
Enter/Exit Programming Mode
$CPWEB
Set String ID
Sets the identifier of the predefined strings.
Set String ID
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by 6 digits from the Alphanumeric
The ID characters must be represented by their hexadecimal ASCII code; if the first 2 digits are 0, this feature is disabled. End by scanning the ENTER/EXIT bar code again.
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
$CPWED
Set String Header
Sets the header of the predefined strings.
Set String Header
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by 32 digits from the Alphanumeric characters in
Appendix D, Keypad
.
The digits must be the hexadecimal ASCII representation of the desired characters. If less than the expected string of 16 characters are selected, scan the
ENTER/EXIT bar code to terminate the string.
If the first 2 digits are 0, the feature is disabled. End by scanning the ENTER/EXIT bar code again.
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
252 PowerScan™ PD9530/PBT9500/PM9500
Enter/Exit Programming Mode
$CPWEF
Set String Terminator
Sets the terminator of the predefined strings.
Set String Terminator
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at left followed by 32 digits from the Alphanumeric characters in
Appendix D, Keypad.
The digits must be the hexadecimal ASCII representation of the desired characters. If less than the expected string of 16 characters are selected, scan the
ENTER/EXIT bar code to terminate the string.
If the first 2 digits are 0, the feature is disabled. End by scanning the ENTER/EXIT bar code again.
~
Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
CANCEL
Product Reference Guide 253
NOTES
254 PowerScan™ PD9530/PBT9500/PM9500
Chapter 4
References
This section contains explanations and examples of selected bar code fea-
tures. See Configuration Using Bar Codes, starting on page 21
for the actual bar code labels used to configure the reader.
RS-232/USB COM Parameters on page 257
Wedge Quiet Interval on page 264
Intercharacter Delay on page 265
Datamatrix DPM Decoding Safety on page 267
Global Prefix/Suffix on page 270
Character Conversion on page 277
Good Read LED Duration on page 278
Stand Mode Off Time on page 280
Scanning Active Time on page 281
Aiming Duration Time on page 282
Multiple Labels Ordering by Code Symbology on page
Automatic Configuration Update
Motionless Timeout on page 287
Product Reference Guide 255
References
RS-232 Parameters
RS-232 Only
Baud Rate
Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.
Stop Bits
The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. The number of stop bits selected (one or two) depends on the number the receiving terminal is programmed to accommodate. Set the number of stop bits to match host device requirements.
Parity
This feature specifies parity required for sending and receiving data. A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements.
• Select None when no parity bit is required.
• Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.
• Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.
Handshaking Control
The data interface consists of an RS-232 port designed to operate either with or without the hardware handshaking lines, Request to Send (RTS), and
Clear to Send (CTS). Handshaking Control includes the following options:
• RTS — RTS is asserted during transmissions. CTS is ignored.
• RTS/CTS — RTS is asserted during transmissions. CTS gates transmissions.
• RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored.
XON and XOFF gate transmissions.
• RTS On/CTS — RTS is always asserted. CTS gates transmissions.
RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmissions and controls enable and disable state of scanner.
256 PowerScan™ PD9530/PBT9500/PM9500
RS-232 Parameters
RS-232/USB COM Parameters
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
To set the delay:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Go to
page 31 and scan the bar code: SELECT INTERCHARACTER DELAY
SETTING.
5. Scan the appropriate two digits from the keypad in
, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure. See Table 27
for some examples of how to set this feature.
Table 27. Intercharacter Delay Setting Examples
3
4
STEP ACTION
1 Desired Setting
2
Divide by 10 (pad with leading zeroes to yield two-digits)
5
6
EXAMPLES
50ms
05
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT INTERCHARACTER DELAY SETTING
Scan Two Characters From
‘0’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
150ms
15
‘5’ and ‘0’
600ms
60
‘6’ and ‘0’
850ms
85
‘8’ and ‘5’
Product Reference Guide 257
References
ACK NAK Options
This enables/disables the ability of the reader to support the RS-232 ACK/
NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.
Options are:
• Disable
• Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent.
• Enable for host-command acknowledge — The reader will respond with
ACK/NAK when the host sends a command.
• Enable for label transmission and host-command acknowledge
ACK Character
This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit
data is not recognized when the option
Data Bits.
1. Determine the desired character or value.
on the inside back cover of this manual to find the hex equivalent for the desired character/value.
3. Go to
page 33 and scan ENTER/EXIT PROGRAMMING MODE to enter
Programming Mode.
4. Scan the bar code: SELECT ACK CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
, that represent the desired character/value in step
1 above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
See Table 28 for some examples of how to set this feature.
Table 28. ACK Character Setting Examples
STEP ACTION
1
2
3
Desired Character/Value
Hex equivalent from
EXAMPLES
ACK
0x06
Scan ENTER/EXIT PROGRAMMING MODE
4
5
6
Scan SELECT ACK CHARACTER SETTING
Scan Two Characters from
‘0’ and ‘6’
Scan ENTER/EXIT PROGRAMMING MODE
$
0x24
‘2’ and ‘4’
@
0x40
‘4’ and ‘0’
>
0x3E
‘3’ AND ‘E’
258 PowerScan™ PD9530/PBT9500/PM9500
RS-232 Parameters
NAK Character
This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
To set this feature:
1. Determine the desired character or value.
2. Use the
ASCII Chart on the inside back cover of this manual to find the
hex equivalent for the desired character/value.
3. Go to page 33 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT NAK CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
Appendix D, Keypad , that represent the desired character/value in step
1 above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 29
for some examples of how to set this feature.
Table 29. NAK Character Setting Examples
STEP ACTION
1
2
3
Desired Character/Value
Hex equivalent from
EXAMPLES
NAK
0x15
Scan ENTER/EXIT PROGRAMMING MODE
4
5
6
Scan SELECT NAK CHARACTER SETTING
Scan Two Characters From
‘1’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
$
0x24
‘2’ and ‘4’
@
0x40
‘4’ and ‘0’
>
0x3E
‘3’ AND ‘E’
Product Reference Guide 259
References
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to
page 34 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix D, Keypad , that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 30 for some examples of how to
set this feature.
2
3
4
STEP ACTION
Table 30. ACK NAK Timeout Value Setting Examples
EXAMPLES
1 Desired Setting 200ms 1,000ms (1 sec.)
5200ms (5.2 sec.)
26
5
6
Divide by 200 01
Scan ENTER/EXIT PROGRAMMING MODE
05
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘5’ ‘2’ and ‘6’
15,000ms (15 sec.)
75
‘7’ and ‘5’
260 PowerScan™ PD9530/PBT9500/PM9500
RS-232 Parameters
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries.
To set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield three digits. For example:
0 = 000, 5 = 005, 20 = 020, etc.
3. Go to page 34 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT ACK NAK RETRY COUNT SETTING.
5. Scan the appropriate three digits from the keypad in
, that represent the number which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 31
for some examples of how to set this feature.
Table 31. ACK NAK Retry Count Setting Examples
2
3
STEP
1
ACTION
Desired Setting
Pad with leading zero(es)
EXAMPLES
Disable Retry
Count
000
Scan ENTER/EXIT PROGRAMMING MODE
4
5
6
3 Retries
003
Scan SELECT ACK NAK RETRY COUNT SETTING
Scan Three Characters
‘0’, ‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’, ‘0’ and ‘3’
54 Retries
054
‘0’, ‘5’ and ‘4’
Unlimited Retries
255
‘2’, ‘5’ and ‘5’
Product Reference Guide 261
References
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these char-
acters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
3
4
To set the value:
1. Determine the desired character or value. A setting of 0xFF indicates the Disable Character is not used (not available).
on the inside back cover of this manual to find the hex equivalent for the desired character/value.
3. Go to
page 36 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT DISABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
, that represent the desired character/value in step
1 above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 32 for some examples of how to
set this feature.
STEP ACTION
Table 32. Disable Character Setting Examples
EXAMPLES
1 ‘D’
Disable Command
Not Used
2
5
6
Desired character/value ‘d’
Scan Two Characters From
‘6’ and ‘4’
Scan ENTER/EXIT PROGRAMMING MODE
‘}’
0x64
Scan ENTER/EXIT PROGRAMMING MODE
0x7D
Scan SELECT DISABLE CHARACTER VALUE SETTING
‘7’ and ‘D’
0x44
‘4’ and ‘4’
0xFF
‘F’ AND ‘F’
262 PowerScan™ PD9530/PBT9500/PM9500
3
4
RS-232 Parameters
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
To set this feature:
Determine the desired character or value. A setting of 0xFF indicates the
Enable Character is not used (not available).
1. Determine the desired character or value.
2. Use the
ASCII Chart on the inside back cover of this manual to find the
hex equivalent for the desired character/value.
3. Go to page 36 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT ENABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric characters from the keypad in
Appendix D, Keypad , that represent the desired character/value in step
2 above. The second character will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 33
for some examples of how to set this feature.
STEP ACTION
Table 33. Enable Character Setting Examples
EXAMPLES
1 ‘E’
Enable Command
Not Used
2
5
6
Desired character/value ‘e’
Scan Two Characters From
‘6’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
‘}’
Hex equivalent from
0x65
Scan ENTER/EXIT PROGRAMMING MODE
0x7D
Scan SELECT ENABLE CHARACTER VALUE SETTING
‘7’ and ‘D’
0x45
‘4’ and ‘5’
0xFF
‘F’ AND ‘F’
Product Reference Guide 263
References
Keyboard Interface
Wedge Quiet Interval
Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments.
This feature applies ONLY to the Keyboard Wedge interface.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to
page 42 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Prog. Mode.
4. Scan the bar code: SELECT WEDGE QUIET INTERVAL SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix D, Keypad , that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure to set the Wedge Quiet Interval. See Table 34
for some examples of how to set this feature.
Table 34. Wedge Quiet Interval Setting Examples
3
4
STEP ACTION
1 Desired Setting
2
Divide by 10 (and pad with leading zeroes)
EXAMPLES
10ms
01
5
6
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT WEDGE QUIET INTERVAL SETTING
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
150ms
15
‘1’ and ‘5’
600ms
60
‘6’ and ‘0’
850ms
85
‘8’ and ‘5’
264 PowerScan™ PD9530/PBT9500/PM9500
Keyboard Interface
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
This feature applies ONLY to the Keyboard Wedge interface.
To set the delay:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to page 31 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT INTERCHARACTER DELAY SETTING.
5. Scan the appropriate two digits from the keypad in
, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 35
for some examples of how to set this feature.
Table 35. Intercharacter Delay Setting Examples
3
4
STEP ACTION
1 Desired Setting
2
Divide by 10 (and pad with leading zeroes to yield two-digits)
EXAMPLES
50ms
05
5
6
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT INTERCHARACTER DELAY SETTING
Scan Two Characters From
‘0’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
150ms
15
‘1’ and ‘5’
600ms
60
‘6’ and ‘0’
850ms
85
‘8’ and ‘5’
Product Reference Guide 265
References
Intercode Delay
Specifies the delay between labels transmitted to the host for this interface.
The selectable range for this feature is from 0 to 99 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 0
= 00, 5 = 05, 20 = 20, etc
3. Go to
page 42 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT INTERCODE DELAY SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix D, Keypad , that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 36 for some examples of how to
set this feature.
Table 36. Wedge Intercode Delay Examples
2
3
STEP ACTION
1 Desired Setting
4
Pad with leading zero(es)
EXAMPLES
No Delay
00
Scan ENTER/EXIT PROGRAMMING MODE
5
6
Scan SELECT INTERCODE DELAY SETTING
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
5 Seconds
05
‘0’ and ‘5’
60 Seconds
60
‘6’ and ‘0’
99 Seconds
99
‘9’ AND ‘9’
266 PowerScan™ PD9530/PBT9500/PM9500
Symbologies
Symbologies
Datamatrix DPM Decoding Safety
Decoding Safety is used to configure a decoder to be very aggressive to very conservative, depending on a particular customer’s needs.
• Level 1 results in a very aggressive decoder.
• Level 5 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
There are many factors that determine when to change the decoding safety.
These factors include spots, voids, non-uniform backgrounds, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, decrease the decoding safety to be more aggressive. In case of rigorous reliability application requirements it is suggested to use higher decoding safety values (conservative).
Set Length
Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
Set Length 1
This feature specifies one of the bar code lengths for Length Control. Length
1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only.
The number of characters that can be set varies, depending on the symbology. Reference the page for your selected symbology to see specific variables.
1. Determine the desired character length (varies depending on symbology). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Go to the Set Length page for your selected symbology and scan the
ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
3. Scan the bar code to SELECT LENGTH 1 SETTING for your selected symbology.
4. Scan the appropriate two digits from the keypad in
, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Product Reference Guide 267
References
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Prog Mode.
Set Length 2
This feature allows you to set one of the bar code lengths for the specified symbology. Length 2 is the maximum label length if in Variable Length
Mode, or the second fixed length if in Fixed Length Mode. See the page for the specific symbology for parameters.
The length that can be set varies depending on the symbology. A setting of
0 specifies to ignore this length (only one fixed length).
Follow these instructions to set this feature:
1. Determine the desired character length (from 1 to 50 — or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
2. Go to the Set Length page for your selected symbology and scan the
ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
3. Scan the bar code to SELECT LENGTH 2 SETTING for your selected symbology.
4. Scan the appropriate two digits from the keypad in
that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake, before the last character scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure.
268 PowerScan™ PD9530/PBT9500/PM9500
Data Editing
Data Editing
It is not recommended to use these features with IBM interfaces.
CAUTION
When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The Data
Editing features can be used to build specific user-defined data into a message string.
There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbologies. Figure 7 shows the available elements you can add to a message string:
Figure 7. Breakdown of a Message String
Label ID Transmission:
Enable this option to transmit the Label ID you configure for the scanned symbology.
OR...
Prefix Label ID AIM ID Bar Code Data Label ID Suffix
AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data.
00 - 20 Characters (ASCII)
Additional advanced editing is available. See the Advanced formatting features in the Datalogic Aladdin configuration software, or contact
Technical Support (as described on page 2
) for more information.
Please Keep In Mind...
• Modifying a message string is not a mandatory requirement. Data editing is a sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.
• A prefix or suffix may be applied only to a specified symbology (reference
1D Symbologies, starting on page 81
or
2D Symbologies, starting on page 173
) or across all symbologies (set via the Global features in this chapter).
• You can add any character from the
(from 00-FF) on the inside back cover of this manual as a prefix, suffix or Label ID.
• Enter prefixes and suffixes in the order in which you want them to appear on the output.
Product Reference Guide 269
References
Global Prefix/Suffix
Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/or as a suffix (in a position following the bar code data) as indicated in Figure 8.
Figure 8. Prefix and Suffix Positions
OR...
Prefix Label ID AIM ID Bar Code Data
00 - 20 Characters (ASCII)
AND
OR
Label ID Suffix
Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies.
1. Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix.
2. Go to
page 50 and scan the ENTER/EXIT PROGRAMMING MODE bar
code, then scan the SET GLOBAL PREFIX bar code.
3. Reference the
ASCII Chart on the inside back cover of this manual to
find the hex value assigned to the desired character. The corresponding hex number for the ‘$’ character is 24. To enter this selection code,
scan the ‘2’ and ‘4’ bar codes from Appendix D, Keypad .
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
4. If less than the expected string of 20 characters are selected, scan the
ENTER/EXIT bar code to terminate the string.
5. Scan the ENTER/EXIT bar code once again to exit Programming Mode.
6. The resulting message string would appear as follows:
Scanned bar code data:
12345
Resulting message string output:
$12345
Global AIM ID
This feature enables/disables addition of AIM IDs for all symbology types.
AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows:
• A close brace character (ASCII ‘]’), followed by...
• A code character (see the table below), followed by...
270 PowerScan™ PD9530/PBT9500/PM9500
Data Editing
• A modifier character (the modifier character is symbol dependent).
SYMBOLOGY
UPC/EAN
Code 39 and
Code 32
Codabar
Interleaved 2 of 5
Code 93
CHAR SYMBOLOGY
E a
A
F
I
G
Code 128/GS1-128
DataBar Omnidirectional, DataBar
Expanded
Standard 2 of 5
ISBN
Code 11
CHAR
C e
S
X b
H a. UPC-A and UPC-E labels are converted to EAN 13 when adding
AIM IDs.
b. ISBN (X with a 0 modifier character)
Figure 9. AIM ID
Prefix Label ID AIM ID Bar Code Data Label ID Suffix
Product Reference Guide 271
References
Label ID
A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x01-0xFF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options
"Label ID: Set Individually Per Symbology" on page 275). If you wish to program the reader to
always include an industry standard label identifier for ALL symbology types, see
Label ID: Pre-loaded Sets
The reader supports two pre-loaded sets of Label IDs. Table 37 shows the
USA and the EU sets.
CAUTION
When changing from one Label ID set to another, all other reader configuration settings, including the host interface type, will be erased and set to the standard factory defaults. Any custom configuration or custom defaults will be lost.
Symbology
ABC CODABAR
ANKER PLESSEY
AZTEC
CHINA SENSIBLE CODE
CODABAR
CODE11
CODE128
CODE32
CODE39
CODE39 CIP
CODE39 DANISH PPT
CODE39 LAPOSTE
CODE39 PZN
CODE93
DATABAR 14
DATABAR 14 COMPOSITE
DATABAR EXPANDED
Table 37 . Label ID Pre-loaded Sets
USA Label ID set
Default
Character
$Z
&
R4
R4
RX
$Y
$a
*
Y
#
A
%
CE
Az
$S
S o
Default
ASCII
2A0000
590000
245900
246100
245A00
260000
523400
523400
525800
530000
6F0000
417A00
245300
250000
434500
230000
410000
272
EU Label ID set
Default
Character u c
$Z
U t
$Y
$a
V
Y
T
X
R b
!
$S
S o
Default
ASCII
560000
590000
245900
246100
245A00
550000
750000
523400
740000
530000
6F0000
210000
245300
520000
620000
540000
580000
PowerScan™ PD9530/PBT9500/PM9500
Symbology
DATABAR EXPANDED COMPOSITE
DATABAR LIMITED
DATABAR LIMITED COMPOSITE
DATA MATRIX
EAN128
EAN128 COMPOSITE
EAN13
EAN13 P2
EAN13 P5
EAN13 COMPOSITE
EAN8
EAN8 P2
EAN8 P5
EAN8 COMPOSITE
FOLLET 2OF5
GTIN
GTIN2
GTIN5
I2OF5
IATA INDUSTRIAL 2OF5
INDUSTRIAL 2OF5
ISBN
ISBT128 CONCAT
ISSN
MAXICODE
MICRO QR
MICRO PDF
MSI
PDF417
PLESSEY
POSTAL AUSTRALIAN
POSTAL IMB
Product Reference Guide
USA Label ID set
Default
Character
RX
RL
RL
Dm
Default
ASCII
4D4300
245100
6D5000
400000
500000
610000
244B00
245600
473200
473500
690000
494100
570000
490000
660000
6E0000
460000
460000
464600
464600
464600
464600
4F0000
470000
525800
524C00
524C00
446D00
000000
000000
460000
460000
W
I i
IA
G2
G5
O
G
FF
FF
FF
FF
F
F
F
F mP
@
P a f n
MC
$Q
$K
$V
Data Editing
EU Label ID set
Default
Character
$K
$V r a
8
Z x
$Q f n
W
@
N
&
$B
$C
K
$G
O
$A
A
J
M
$F
B
L k
$E i w d v
Default
ASCII
780000
245100
380000
5A0000
720000
610000
244B00
245600
244200
244300
4E0000
260000
570000
400000
660000
6E0000
4D0000
244600
410000
4A0000
4B0000
244700
4F0000
244100
525800
760000
524C00
770000
6B0000
244500
420000
4C0000
273
References
Symbology
POSTAL JAPANESE
POSTAL KIX
POSTAL PLANET
POSTAL PORTUGAL
POSTAL POSTNET BB
POSTAL ROYAL MAIL
POSTAL SWEDISH
POSTNET
QR CODE
S25
TRIOPTIC
UPCA
UPCA P2
UPCA P5
UPCA COMPOSITE
UPCE
UPCE P2
UPCE P5
UPCE COMPOSITE
USA Label ID set
Default
Character
A
E
A
A
QR s
$T
A
E
E
E
$L
$M
$X
1
$R
$U
$W
$P
Default
ASCII
515200
730000
245400
410000
410000
410000
410000
450000
245200
245500
245700
245000
244C00
244D00
245800
310000
450000
450000
450000
EU Label ID set
Default
Character
$H
D
F
G
$T
C y
P
H
I
$J
$L
$M
$X
1
$R
$U
$W
$P
Default
ASCII
790000
500000
245400
430000
460000
470000
244800
440000
245200
245500
245700
245000
244C00
244D00
245800
310000
480000
490000
244A00
274 PowerScan™ PD9530/PBT9500/PM9500
Data Editing
Label ID: Set Individually Per Symbology
To configure a Label ID individually for a single symbology:
1. Go to
and scan the ENTER/EXIT bar code.
2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER
(Enable as suffix) by scanning the appropriate bar code in the section
"Label ID Control" on page 56. Reference Figure 10 for Label ID posi-
tioning options if multiple identification features are enabled.
3. Scan a bar code to select the symbology for which you wish to config-
ure a custom Label ID from the section "Label ID Symbology Selection −
4. Determine the desired character(s) (you may choose up to three) which will represent the Label ID for the selected symbology.
5. Turn to the ASCII Chart on the inside back cover of this manual and find
the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart
determined. For the example given, the characters ‘3’ and ‘D’ would be
scanned. More examples of Label ID settings are provided in Table 38
.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT bar code to exit Label ID entry.
7. Scan the ENTER/EXIT bar code once again to exit Programming Mode.
This completes the steps to configure a Label ID for a given symbology.
Figure 10. Label ID Position Options
Prefix Label ID Aim ID
OR
Bar Code Data Label ID Suffix
Product Reference Guide 275
References
Table 38 . Label ID Examples
STEP ACTION
1.
Scan the ENTER/EXIT bar code
EXAMPLES
2.
3.
4.
5.
6.
7.
(Scanner enters Programming Mode)
Determine placement of the Label ID characters
BEFORE or AFTER with regard to scanned data using
Enable as Prefix Enable as Suffix Enable as Prefix
Scan the bar code selecting the symbology type you wish to designate label ID characters for using
1D Symbologies, starting on page 57
DataBar
Omnidirectional
Code 39
Interleaved 2 of
5
Custom Label ID example
(desired characters):
D B * = C 3 +
Find hex equivalents from the
(inside back cover), then scan in these digits/characters using the bar codes in the
a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
44 42 2A 3D 43 33 2B
Scan the ENTER/EXIT bar code
Scan the ENTER/EXIT bar code once again
(Scanner exits Label ID entry)
(Scanner exits Programming Mode)
Enable as Suffix
Code 32
P H
50 48
Result:
DB*[bar code data]
[bar code data]=C3
+[bar code data] [bar code data]PH
276 PowerScan™ PD9530/PBT9500/PM9500
Data Editing
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are
4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is
FF, then no conversion is done.
For example, if you have the character conversion configuration item set to the following: 41423132FFFFFFFF
The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an
ASCII 2). The other two pairs are FFFF and FFFF.
With the label, AB12BA21, it would look as follows after the character conversion: BB22BB22.
The A characters were converted to B characters and the 1 characters were converted to 2 characters. Nothing is done with the last two character pairs, since they are all FF.
To set Character Conversion:
1. Go to
and scan the ENTER/EXIT bar code.
2. Scan the “Configure Character Conversion” bar code.
3. Determine the desired string. Sixteen positions must be determined as
in the above example. Next, turn to the ASCII Chart
on the inside back cover of this manual and find the equivalent hex digits needed to fulfill the string.
4. Turn to Appendix D, Keypad and scan the bar codes representing the
hex characters determined in the previous step.
5. Scan the ENTER/EXIT bar code to exit Programming Mode.
If less than the expected string of 16 characters are selected, scan the
ENTER/EXIT bar code twice to accept the selections and exit Programming Mode.
Product Reference Guide 277
References
Reading Parameters
Good Read LED Duration
This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in
100ms increments.
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled.
2. Divide the desired setting by 10 (setting is in 100ms increments). Pad the result with leading zeroes to yield three digits. For example: 0 =
000, 5 = 000, 20 = 020, etc.
3. Go to
page 70 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT GOOD READ LED DURATION SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix D, Keypad representing the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 39 for some examples of how to
set this feature.
Table 39. Good Read LED Duration Setting Examples
3
4
STEP
1
2
5
6
ACTION
Desired Setting
EXAMPLES
Good Read LED stays on until next trigger pull
(00)
20ms
Divide by 10 (and pad with leading zeroes)
000 002
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT GOOD READ LED DURATION SETTING
Scan Three Characters
From
‘0’, ‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’, ‘0’ and ‘2’
150ms
015
‘0’, ‘1’ and ‘5’
2550ms (2.55 sec.)
255
‘2’, ‘5’ and ‘5’
278 PowerScan™ PD9530/PBT9500/PM9500
Scanning Features
Scanning Features
Scan Mode
This mode is associated with typical handheld reader operation. Selects the scan operating mode for the reader. The following selections are valid for all models:
Trigger Single:
When the trigger is pulled, scanning is activated until one of the following occurs:
-
- a label has been read
- the trigger is released
Trigger Hold Multiple:
When the trigger is pulled, scanning starts and the product scans until the trigger is released or
has
elapsed. Reading a label does not disable scanning. Double Read Timeout
prevents undesired multiple reads of the same label while in this mode.
Trigger Pulse Multiple:
When the trigger is pulled, continuous scanning is activated until
Scanning Active Time has elapsed or the trigger has been
released and pulled again.
prevents undesired multiple reads of the same label while in this mode.
Flashing:
The reader flashes on and off regardless of the trigger status. Flash
rate is controlled by Flash On Time and Flash Off Time . When Flash is ON the
imager reads continuously; when Flash is OFF scanning is deactivated.
Always On:
No trigger pull is required to read a bar code. Scanning is continually on. If the trigger is pulled, the reader acts as if it is in Trigger Single
Mode.
Double Read Timeout prevents undesired multiple reads of the same
label while in this mode.
Stand Mode:
No trigger pull is required to read a bar code. Scanning is turned on automatically when an item is placed in the reader’s field of view.
prevents undesired multiple reads while in this mode.
Product Reference Guide 279
References
Stand Mode Off Time
This feature specifies the amount of time reader illumination stays off after pulling the trigger when in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16 seconds).
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield two digits. For example: 2 =
02, 5 = 05, 20 = 20, etc.
3. Go to
page 73 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: Set Stand Mode Illuminator Off Time.
5. Scan the appropriate two digits from the keypad in
Appendix D, Keypad , that represent the setting which was determined in the steps
above. You will hear a two-beep indication after the last character.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 40 for some examples of how to
set this feature.
Table 40. Stand Mode Off Time
2
3
4
STEP ACTION
1 Desired Setting
Pad leading zero
EXAMPLES
500 ms
01
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT STAND MODE OFF TIME
5
6
Scan Two Characters From
‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
1 Second
02
‘0’ and ‘2’
5.5 Seconds
11
‘1’ and ‘1’
16 Seconds
32
‘3’ and ‘2’
280 PowerScan™ PD9530/PBT9500/PM9500
Scanning Features
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0
= 000, 5 = 005, 20 = 020, etc.
3. Go to page 74 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING.
5. Scan the appropriate three digits from the keypad in
, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 41
for some examples of how to set this feature.
2
3
4
STEP ACTION
Table 41. Scanning Active Time Setting Examples
EXAMPLES
1
5
6
Desired Setting 1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.)
180
255 Seconds (4.25 min.)
255 Pad leading zero(es) 001
Scan ENTER/EXIT PROGRAMMING MODE
090
Scan SELECT SCANNING ACTIVE TIME SETTING
Scan Three Characters
‘0’, ‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
Product Reference Guide 281
References
Aiming Duration Time
Specifies the frame of time the aiming pointer remains on after decoding a label, when in trigger single mode. The range for this setting is from 1 to
255 seconds in 1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0
= 000, 5 = 005, 20 = 020, etc.
3. Go to
page 76 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT AIMING DURATION TIME SETTING.
5. Scan the appropriate three digits from the keypad in
Appendix D, Keypad , that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 42 for some examples of how to
set this feature.
2
3
4
STEP ACTION
Table 42. Aiming Duration Time Setting Examples
EXAMPLES
1
5
6
Desired Setting 1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.)
180
255 Seconds (4.25 min.)
255 Pad leading zero(es) 001
Scan ENTER/EXIT PROGRAMMING MODE
090
Scan SELECT AIMING DURATION TIME SETTING
Scan Three Characters
From
‘0’, ‘0’ and ‘1’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
282 PowerScan™ PD9530/PBT9500/PM9500
Scanning Features
Flash On Time
This feature specifies the ON time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to page 74 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT FLASH ON TIME SETTING.
5. Scan the appropriate two digits from the keypad in Appendix D, Keypad
representing the duration which was determined in the steps above.
You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 43
for examples of how to set this feature.
3
4
STEP ACTION
Table 43. Flash On Time Setting Examples
EXAMPLES
1
2
5
6
Desired Setting 500ms
Divide by 100 (and pad with leading zeroes to yield two digits)
05
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT FLASH ON TIME SETTING
Scan Two Characters From
‘0’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
1,000ms (1 sec.)
10
‘1’ and ‘0’
5200ms (5.2 sec.)
52
‘5’ and ‘2’
9,900ms (9.9 sec.)
99
‘9’ and ‘9’
Product Reference Guide 283
References
Flash Off Time
This feature specifies the OFF time for the indicator LED while in Flash Mode.
The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in
100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Go to
page 75 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: SELECT FLASH OFF TIME SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix D, Keypad , that represent the duration which was determined in the steps
above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 44 for some examples of how to
set this feature.
3
4
STEP ACTION
Table 44. Flash Off Time Setting Examples
EXAMPLES
1
2
5
6
Desired Setting 500ms
Divide by 100 (and pad with leading zeroes to yield two digits)
05
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT FLASH OFF TIME SETTING
Scan Two Characters From
‘0’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
1,000ms (1 sec.)
10
‘1’ and ‘0’
5200ms (5.2 sec.)
52
‘5’ and ‘2’
9,900ms (9.9 sec.)
99
‘9’ and ‘9’
284 PowerScan™ PD9530/PBT9500/PM9500
Scanning Features
Multiple Labels Ordering by Code Symbology
This feature Specifies the transmission ordering by symbology type, when
Multiple Labels per Frame is enabled.Up to six symbologies can be selected.
Zeroes must be added to pad the string to 12 characters if not using all six symbologies.
The labels are ordered first as specified in the output mask. Labels present in the volume but not specified will be transmitted as unspecified symbologies in random order as allowed by the reading time sequence. For each label decoded in the volume the reader signals the standard beeper and LED indications.
To specify the symbology order:
1. Determine the symbologies and order you want to specify.
to find the hex values for up to six symbologies.
3. Go to page 80 and scan the ENTER/EXIT PROGRAMMING MODE bar code
to enter Programming Mode.
4. Scan the bar code: “SELECT SYMBOLOGIES FOR MULTIPLE LABELS
ORDERING”.
5. Scan the appropriate two alphanumeric characters from the keypad in
Appendix D, Keypad , that represent the desired character/value in step
2 above.
6. Scan zeroes if needed to make a 12-character string.
7. When finished, scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 45
for some examples of how to set this feature.
Table 45. Multiple Labels Ordering by Code Symbology Examples
STEP ACTION
1
2
3
Desired symbology
Hex equivalent from
EXAMPLES
Code 39
24
Scan ENTER/EXIT PROGRAMMING MODE
4
5
6
Data Matrix
0E
Code 128
0C
Scan SELECT SYMBOLOGIES FOR MULTIPLE LABELS ORDERING
Scan Two Characters From
RESULT
‘2’ and ‘4’
0x240E0C4E0000
‘0’ and ‘E’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘C’
Aztec
4E
‘4’ and ‘E’
Table 46 on page 286 shows the hex value associated with each symbology.
Product Reference Guide 285
References
2A
2B
Table 46 . Symbology Hex Values
Symbology ID Hex
Value
Don't care
UPC-A
UPC-E
EAN8
EAN13
UPC2
UPC5
C128_ADDON
2C
2D
2E
2F
30
31
32
33
EAN128 34
C128_PROGRAMMING_LABEL 35
CODE128
FNC3_C128_LABEL
36
37
38 DATA MATRIX
MAXICODE
QRCODE
Reserved
39
3A
3B
3C Reserved
CODE49
UPC-E2
UPC-E5
Reserved
UPC-A2
UPC-A5
Reserved
3D
3E
3F
40
42
43
44
45 EAN82
EAN85
Reserved
EAN132
EAN135
EAN138
ISBN_ID
TWO_LABEL_PAIR
I2OF5
CODABAR
CODE39
PHARMAC39
MSI_PLESSEY
CODE93
RSS_EXP_ID
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
RSS_14_ID
54
GTIN
GTIN2
55
FF
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
24
25
26
27
20
21
22
23
28
29
0C
0D
0E
0F
06
07
0A
0B
02
03
04
05
Hex
Value
00
01
286
Symbology ID
GTIN5
GTIN8
S2OF5
PDF417
CODE11
IATA
MICRO_PDF
GS1 DataBar_LIM_ID
GS1 DataBar_LIM_COMP
GS1 DataBar_Omnidirectional_COMP
GS1 DataBar_EXP_COMP
GENERIC_DATA
CC_A
CC_B
CC_C
LABELIMAGE
CAPTURE_IMAGE_LABEL
Reserved
M2OF5
D2OF5
PLESSEY65
ISSN
ISBT
Reserved
TIMER_EXPIRED_EVENT
FOLLETT_2OF5
Reserved
Reserved
CODE39_CIP
ABC_CODABAR
I2OF5_CIP
C2OF5
IND2OF5
AZTEC
UPC-E_COMP
UPC-A_COMP
EAN8_COMP
EAN13_COMP
EAN128_COMP
DATA MATRIX_PROGRAMMING_LA-
BEL
LABEL_ID_MAX
INVALID_LABEL_TYPE
PowerScan™ PD9530/PBT9500/PM9500
Motion Features
Motion Features
Motionless Timeout
This setting specifies the amount of time that the reader takes to assume that it is in a motionless condition. The range for this setting is from 500 msec to 25.5 seconds, in 100 millisecond increments.
Follow these instructions to set this feature.
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0.5
= 0005 = 00, 5 = 050, 20 = 200, etc.
3. Go to
and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode.
4. Scan the bar code: SELECT MOTIONLESS TIMEOUT SETTING.
5. Scan the appropriate three digits from the keypad in
representing the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
This completes the procedure. See Table 47 for examples of how to set this feature.
Table 47. Motionless Timeout Setting Examples
3
4
STEP ACTION
1 Desired Setting
2
Divide by 100 (and pad with leading zeroes to yield two digits)
EXAMPLES
500ms
005
5
6
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT MOTIONLESS TIMEOUT SETTING
Scan Two Characters From
‘0’, ‘0’ and ‘5’
Scan ENTER/EXIT PROGRAMMING MODE
1 sec.
010
‘0’, ‘1’ and ‘0’
10 sec
100
‘1’, ‘0’, and ‘0’
9,900ms (9.9 sec.)
250
‘2’, ‘5’, and ‘0’
Product Reference Guide 287
References
Wireless Features
Automatic Configuration Update
When this feature is enabled, the base station and reader will keep their configurations synchronized. If a reader's configuration is altered by reading programming labels, this change is automatically transferred and updated in a linked base station. Likewise, if the base station's configuration is changed using Aladdin or by host commands, then the reader's configuration will automatically be updated if this feature is enabled.
RF Address Stamping
Source Radio Address Delimiter Character
This option specifies the delimiter character to be placed between the label data and radio address when address stamping is enabled.
"Source Radio Address Transmission" on page 217 is enabled.
Follow these instructions to select the delimiter character:
1. Determine the desired character, then find its hexadecimal equivalent on the
ASCII Chart on the inside back cover. A setting of 00 specifies no
delimiter character.
2. Go to
page 218 and scan the ENTER/EXIT PROGRAMMING MODE bar
code to enter Programming Mode.
3. Scan the bar code: SET SOURCE RADIO ADDRESS DELIMITER CHARAC-
TER.
4. Scan the appropriate two digits from the keypad in
Appendix D, Keypad , that represent the hexadecimal characters which were determined
in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
5. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
Table 48. Source Radio Address Delimiter Character Setting Examples
STEP
1
2
ACTION
Desired Setting
EXAMPLES
No delimiter character
Scan ENTER/EXIT PROGRAMMING MODE
3
4
5
, (comma)
Scan SET SOURCE RADIO ADDRESS DELIMiTER CHARACTER
Scan Two Characters From
‘0’ and ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
‘2’ and ‘C’
- (dash)
‘2’ and ‘D’
/ (slash)
‘2’ AND ‘F’
288 PowerScan™ PD9530/PBT9500/PM9500
Wireless Features
STAR Radio Protocol Timeout
This parameter sets the valid wait time before transmission between the handheld reader and Base Station is considered failed.
When setting this parameter, take into consideration the radio traffic (number of readers in the same area). The selectable range for this feature is from
02 to 25 seconds.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the number with leading zeroes to yield two digits. For example: 2
= 02, 5 = 05, 25 = 25, etc
3. Go to
and scanScan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode.
4. Scan the barcode: SELECT RADIO PROTOCOL TIMEOUT.
5. Scan the appropriate two digits from the keypad in
, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See Table 49 for some examples of how to set this feature.
Table 49. STAR Radio Protocol Timeout Examples
2
3
4
STEP ACTION
1 Desired Setting
Pad with leading zero(es)
EXAMPLES
2 Seconds
02
Scan ENTER/EXIT PROGRAMMING MODE
5 Seconds
05
Scan SELECTSTAR RADIO PROTOCOL TIMEOUT SETTING
5
6
Scan Two Characters From
‘0’ and ‘2’
Scan ENTER/EXIT PROGRAMMING MODE
‘0’ and ‘5’
10 Seconds
10
‘1’ and ‘0’
25 Seconds
25
‘2’ AND ‘5’
Product Reference Guide 289
References
PM9500-Only Features
Changing System Speed in Normal Mode
1. Link the PM9500 with a BC9xxx Base.
2. With the PM9500, read a Compatible Mode programming label on
to set low, intermediate, or high speed.
3. Place the PM9500 into the BC9xxx.
The Reader and Base will now be linked at the new programmed speed.
This feature can also be programmed using Datalogic Aladdin.
1. On the BC9xxx Base, change the Compatible mode parameter to low, intermediate, or high speed through Aladdin.
2. Place an unlinked PM9500 onto the BC9xxx base.
The Reader and base will link with the new programmed speed.
Bluetooth-Only Features
Bluetooth Pin Code
This option specifies the 4-character or 16-character pin code to be used for authentication of the Bluetooth link. To set the pin code:
1.
Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode, then enable "Bluetooth Security Mode" on page 224 .
2.
Specify the desired pin code length (4 or 16) by scanning the appropri-
ate bar code in "Select PIN Code Length" on page 224.
3. Determine the desired characters. For example, D254 or
STOR12345678135M.
4. Convert the characters to hexadecimal using the
on the inside back cover of this manual.
5. Go to
page 224 and Scan the bar code: SET 4 CHAR PIN CODE or SET
16-CHAR PIN CODE.
6. Scan the appropriate alphanumeric characters from the keypad in
Appendix D, Keypad , representing the hexadecimal entries determined
in the steps above. You will hear a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
290 PowerScan™ PD9530/PBT9500/PM9500
Wireless Features
7. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming Mode.
Changing the pin code setting will unlink the devices. If the Automatic
Configuration Update is set to the default enabled setting, the devices must only be relinked. If the Automatic Configuration Update is set to the disabled setting, the Pin Code setting must also be updated in the Base
Station using Aladdin. After the Base Station has been updated, the devices must be relinked.
Table 50. Bluetooth Pin Code Setting Examples
3
4
STEP ACTION
1 Desired Setting
2
EXAMPLES
D254 STOR12345678135M
Convert the characters to hexadecimal
44 32 35 34
Scan ENTER/EXIT PROGRAMMING MODE
53 54 4F 52 31 32 33 34 35 36 37 38 31 33 35 4D
5
6
Scan SET Bluetooth PIN CODE
Scan 8 or 32
Alphanumeric
Characters From
44323534
Scan ENTER/EXIT PROGRAMMING MODE
53544F5231323334353637383133354D
Product Reference Guide 291
References
NOTES
292 PowerScan™ PD9530/PBT9500/PM9500
Chapter 5
Message Formatting
Message Formatting is available for PM9500 models only.
For this feature to be operational, the scanner must be set to
Ignore Host Commands (see
A message from the Host to the base must follow these rules:
• If Address stamping options or address delimiter are enabled on the base, the Host replay must have address field and delimiter too. Otherwise the message will be ignored. Address delimiter is present only when address stamping is enabled.
• Address stamping is necessary to correctly route the message to the
PM9500, especially when more than one handheld is linked to the same base. Address stamping could be disabled if the system is in point to point configuration. If address stamping is not enabled, the messages are addressed to the first handheld linked to the base.
• The maximum character length for messages is 48.
• Messages end with “CR” 0x0D ASCII character. The CR character cannot be contained in the middle.
• Messages cannot start with '$' or # because these are reserved for Service mode command
• Base station can receive host message only if Host Commands Obey/
Ignore is set to Ignore.
• Message could be sent to the handheld in response to a Label when
“Transmit mode” require Ack from Host (see transmit mode parameter) or at any time. When messages are sent not in response to a label must start with DC2 0x12 ASCII character and could be sent in any transmit mode setting.
• Message could be sent to all handhelds linked to the base by using a
Multicast message:
“00 00 00 00 2A AA”
• In order to receive a message, handhelds must not be in sleep state.
The format of the ACK from Host message (used for transmission mode 02) is:
[Scanner_Addr] [Scanner_Addr_delimiter] MESSAGE <CR>
The format of a generic message From Host to HH is:
[Scanner_Addr] [Scanner_Addr_delimiter] DC2 MESSAGE <CR> where DC2 is ASCII 0x12 (^R) character.
[Items in square brackets are optional.]
• If you want to control the Scanner's beeper from the host, you will also probably want to disable the good transmission beep that is emitted
when the code is received from the cradle. (See " Wireless Beeper Features" on page 209 ).
The message field can store plain text and escape sequences.
• Escape sequences are interpreted as commands.
Product Reference Guide 293
Message Formatting
Cursor Control
ESC [ n A
ESC [ n B
ESC [ n C
ESC [ n D
ESC [ G
ESC [ r ; c H
ESC D
ESC E
ESC M
Up n rows, no scroll
Down n rows, no scroll
Right n columns
Left n columns
CR
Move to row r, column c
(ESC[1;1H is the upper left character position of the display)
Down 1 row, with scroll
CR and cursor down 1 row with scroll
Up 1 row and scroll
• Since CR is used as the message terminator, you must use ESC [ G or ESC E to print a CR.
• The cursor row position is not affected by the currently selected font. The display always has 4 rows, so when writing with the large font, actually two rows are written to: the current one and the one below it. You will need two ESC E commands to step from one row to the next when using the large font.
• The cursor column position is affected by the currently selected font. Therefore, column 6 is 36 pixels from the left border only if you last selected the 6x8 font; otherwise it could be 48 or 72 pixels from the left border.
Font Selection
ESC [ 0 m
ESC [ 7 m
ESC # 4
ESC # 5
ESC # 7
Normal mode
Reverse mode
Large font: subsequent characters are written on the current row and the row below it using the 12x16 font which allows for two rows of eight characters on the display.
Normal font: subsequent characters are written using the 6x8 font, which allows for four rows of sixteen characters on the display.
Medium font: subsequent characters are written using the 8x8 font, which allows for four rows of twelve characters on the display.
Clearing Display
ESC [ 0 K
ESC [ 1 K
ESC [ 2 K
ESC [ 0 J
ESC [ 1 J
ESC [ 2 J
From cursor position to end of line inclusive
From beginning of line to cursor position (not inclusive)
Entire line
From cursor position to end of display inclusive
From beginning of display to cursor position (not inclusive)
Entire display; moves cursor to upper left corner on display
294 PowerScan™ PD9530/PBT9500/PM9500
LED and Beeper Control
ESC [ 0 q
ESC [ 1 q
ESC [ 2 q
ESC [ 3 q
ESC [ 4 q
ESC [ 5 q
ESC [ 6 q
ESC [ 7 q
ESC [ 8 q
ESC [ 9 q
Emit short High tone + short delay
Emit short Low tone + short delay
Emit long Low tone + short delay
Emit good read tone
Emit bad tx tone
Wait 100 ms
Turn on the green LED
Turn off the green LED
Turn on the red LED
Turn off the red LED
The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination with the Beeper. The
LED and Beeper will be controlled by the system after the entire command sequence is interpreted.
Example:
ESC [ 6 q ESC [ 3 q ESC [ 7 q
ESC [ 6 q ESC [ 5 q ESC [ 7 q
Turns on the green LED, emits a good read tone, and turns off the green LED.
Turns on the green LED for 100 ms and then turns off the green LED.
Setting RTC
ESC [ 0 p d d m m y y
ESC [ 1 p h h m m
Set date to day, month, year
Set time to hours, minutes; seconds are automatically set to 00.
Product Reference Guide 295
Message Formatting
NOTES
296 PowerScan™ PD9530/PBT9500/PM9500
Appendix A
Technical Specifications
The tables that follow contain Physical and Performance Characteristics,
User Environment and Regulatory information.
Cable Pinouts.
Table 51. Technical Specifications
Item
Physical Characteristics
Dimensions
Height: 212 mm
Length: 110 mm
Width: 74 mm
Weight (without cable)
Electrical Characteristics
330 gr (without cable)
Description
Voltage & Current
PD9530 models
PD9530/
PD9530-HP
PD9530-HPE PD9530-DPM
Input Voltage
Input Current
Operating (typical):
Operating (max):
Idle/Standby (typical)
5 VDC +/- 5% 10 to 30 VDC
335mA
475mA
180mA
135mA @ 10V
300mA @ 10V
60mA @ 10V
PBT9500 and PM9500 models
5 VDC +/- 5%
350mA
480mA
120mA
Battery Type
Charge time for full charge from full discharge
Li-Ion battery pack
4 hours with external power supply adapter a
Typical 10 hours with Host power (in this case no supply adapter is needed) a
Operating autonomy
(continuous reading)
30,000 reads (typical)
Cradle consumption and
DC input supply range
Volt 10-30 VDC; Power <8W b
;
Max 500mA when in host/bus powered mode b
.
a. Charge Times are much lower when battery is within daily typical operating condition.
b. Typical input current measured under factory default configuration.
Product Reference Guide 297
Technical Specifications
Performance Characteristics
Light Source
Roll (Tilt) Tolerance
Pitch Tolerance
Skew (Yaw) Tolerance
Print Contrast
Minimum
LED
± 180°
± 40°
± 40°
15% minimum reflectance
Resolution
Standard Optics Model
Max resolution 1D 4 mils
Max resolution 2D 7.5 mils
High Performance (HP)
1D 2.5 mil
2D 4 mil
Depth of Field (Typical)
a
Symbology
Code 39
Standard Optics Model
4 mils: 6-17 cm
20 mils: 4-55 cm
40 mils: 4-85 cm
EAN 13 13 mils: 4-48 cm 13
High Performance (HP)
2.5 mils: 2-6 cm
20 mils: 3-70 cm
40 mils: 3-110 cm
13 mils: 3-60 cm
PDF-417 10 mils: 2-25 cm 10 mils: 2-30 cm
DataMatrix
7.5 mils: 7-14 cm
10 mils: 4-18 cm
4mil: 2-6 cm
10mil: 2-20 cm
Minimum Element
Width
Standard Range:
1D Minimum Resolution = 4 mil
PDF-417 Minimum Resolution
= 5 mil
Data Matrix Minimum Resolution
= 7 mil
High Density:
1D Minimum Resolution
= 2.5 mil
PDF-417 Minimum Resolution
= 4 mil
Data Matrix Minimum Resolution = 5 mil a
13 mils DOF based on EAN. All other 1D codes are Code 39. All labels grade A, 300 lux ambient light, 20°C, label inclination 10°
298 PowerScan™ PD9530/PBT9500/PM9500
Decode Capability
Item Description
1D Bar Codes
2D / Stacked Codes
GS1 Databar linear codes, UPC/EAN (A,E,13,8), UPC/EAN with P2/
P5 Addons, UPC/EAN Coupons, ISBN, Code128, EAN128, ISBT128,
Code39, Code39 Full ASCII, Code39 CIP, Code 32, Codabar, Interleaved 2 of 5, IATA, Industrial 2 of 5, Standard 2 of 5, Code11, MSI,
Plessey, Code 93, Follet 2/5
DataMatrix, MaxiCode and QR Codes(QR, Micro QR and Multiple
QR codes), Aztec
- Postal codes including Australian Post, China Post, Japanese
Post, KIX Post, Korea Post, Planet Code, Postnet, Royal Mail Code
(RM45CC), IMB
- stacked codes including EAN/JAN Composites; GS1 Databar
Composites, GS1 Databar Expanded Stacked; GS1 DataBar
Stacked; GS1 DataBar Stacked Omnidirectional; MacroPDF; Micro
PDF417; PDF417; UPC A/E Composites, French CIP13, Grid Matrix
(Chinese) code
High Performance Model:
Same as above.
Interfaces
Supported a
RS-232, Keyboard Wedge (IBM AT-PS/2), USB (USB-KBD, USB-
COM).
a. See "Interface Selection" on page 14 for a listing of available interface sets by model type.
Item
User Environment
Operating
Temperature
Storage Temperature
-40° to 158° F (-40° to 70° C)
Description
-4° to 122° F (-20° - +50° C )
Humidity 0 to 95% non-condensing
Drop Specifications Scanner withstands >50 times 6.5' (2 m) drops to concrete
Ambient Light
Immunity
100,000 Lux
Contaminants
Spray/Rain/Dust/
Particulates
ESD Level
Beeper/Speaker
IP65
20 KV
>= 80 dB @ 10 cm
Product Reference Guide 299
Technical Specifications
Item
Regulatory
Description
Electrical Safety
EMI/RFI
PD9530 (Corded
Models)
UL 60950, CSA C22.2
No. 60950, IEC 60950
PBT9500
UL 60950, CSA C22.2
No. 60950, IEC 60950
North America (FCC) :
Part 15 Class B; Canada ( IC) : ICES-003
Class B; Russia ( Gost);
European Union EMC
Directive;
VCCI-Japan; Korean
KCC; Taiwan EMC
(BSMI); Australia
(ACMA); Mexico (NOM
Nyce)
North America (FCC) :
Canada ( IC); Russia (
Gost); European
Union R&TTE Directive;
Japan; Korean KCC;
Taiwan; Australia;
Mexico
PM9500
UL 60950, CSA C22.2
No. 60950, IEC 60950
433 MHz model
Europe - CE, Russia –
Gost; Australia –
Ctick;
China – SRRC; Singapore – IDA, Anatel
Brazil
910 MHz model
USA/Canada – FCC/
IC; Mexico – NOM +
Cofetel
Laser Safety
IEC Class 2
Radiation 1 mW Avg.,
Emitted wavelength
650 nm, 12ms pulse,
Beam Divergence 8.4 deg x 8.1 deg (“plus” pattern)
IEC Class 2
Radiation 1 mW Avg.,
Emitted wavelength
650 nm, 12ms pulse,
Beam Divergence 8.4 deg x 8.1 deg (“plus” pattern)
IEC Class 2
Radiation 1 mW Avg.,
Emitted wavelength
650 nm, 12ms pulse,
Beam Divergence 8.4 deg x 8.1 deg (“plus” pattern)
Complies with FDA performance standards for laser products except for deviations pursuant to
Laser Notice No. 50, dated June 24, 2007.
Radio Features
PBT9500
Frequency working center
2400 to 2483.5 MHz
Range (in open air) up to 100m
Max number of devices per base station
7
300 PowerScan™ PD9530/PBT9500/PM9500
Imager Labeling
Frequency working center
910MHz
Programmable
Speed
40 kb/s
100 kb/s
500 kb/s (default)
PM9500
Typical Range (in open air)
100m
Max number of devices per base station
16
433MHz
19.2 kb/s
100 kb/s
500 kb/s (default) from 50m
(at 500 kb/s) to 100m
(at 19.2kb/s)
Imager Labeling
Sample labels are shown for illustrative purposes only. Please view the labels on your product for actual details, as they may vary from those depicted.
Scanner Regulatory Label
Product Reference Guide 301
Technical Specifications
Standard Cable Pinouts
The data below provides standard pinout information for the interface cable.
Figure 11. Standard Cable Pinouts: Handheld
302
The signal descriptions in are for reference only.
apply to the connector on the reader and
Table 52.
Standard Cable Pinouts
USB
Keyboard
Wedge
7
8
5
6
3
4
1
2
9
10
Pin RS-232
RTS (out)
GND
RX
TX
VCC
CTS (in)
D+
D-
GND
VCC
CLKIN (KBD side)
DATAIN (KBD side)
GND
VCC
CLKOUT (PC side)
DATAOUT (PC side)
PowerScan™ PD9530/PBT9500/PM9500
LED and Beeper Indications
LED and Beeper Indications
The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming bar code labels.
Table 53. LED and Beeper Indications
INDICATION
Power-up
Beep
Good Read
Beep
Green Spot a flashes momentarily
Image Capture
DESCRIPTION LED BEEPER
The reader is in the process of powering-up.
A label has been successfully scanned by the reader.
Upon successful read of a label, the software turns the green spot on for the time specified by the configured value.
N/A
When ready to capture image
LED behavior for this indication is configurable via the feature “
N/A
Blue light flashes 2 times when updating
N/A
Reader beeps four times at highest frequency and volume upon power-up.
The reader will beep once at current frequency, volume, tonal setting and duration upon a successful label scan.
a. Except when in sleep mode or when a
Good Read LED Duration other than 00 is selected
Table 54. Programming Mode Indications
Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.
INDICATION
Label Programming Mode Entry
Label Programming Mode Rejection of Label
Label Programming Mode Acceptance of Partial
Label
DESCRIPTION
A valid programming label has been scanned.
A label has been rejected.
LED
LED blinks continuously
N/A
BEEPER
Reader sounds four low frequency beeps.
Reader sounds three times at lowest frequency & current volume.
In cases where multiple labels must be scanned to program one feature, this indication acknowledges each portion as it is successfully scanned.
N/A
Reader sounds one short beep at highest frequency & current volume.
Product Reference Guide 303
Technical Specifications
Programming Mode Indications (continued)
INDICATION DESCRIPTION LED
Label Programming Mode Acceptance of
Programming
Configuration option(s) have been successfully programmed via labels and the reader has exited
Programming Mode.
N/A
Label Programming Mode Cancel
Item Entry
Cancel label has been scanned.
N/A
BEEPER
Reader sounds one high frequency beep and 4 low frequency beeps followed by reset beeps.
Reader sounds two times at low frequency and current volume.
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has not passed its automatic Selftest and has entered FRU (Field Replaceable
Unit) isolation mode. If the reader is reset, the sequence will be repeated.
Press and release the trigger to hear the FRU indication code.
The following table describes the LED flashes/beep codes associated with an error found.
1
2
6
11
NUMBER OF
LED FLASHES/
BEEPS
Error
Configuration
Interface PCB
Digital PCB
Imager
CORRECTIVE ACTION
Contact Helpdesk for assistance
Base Station Indications (Cordless Models ONLY)
Base Station Button Indicators
BUTTON PUSH
EVENT
Push at power-up
< 5 sec
5 to 10 sec
CORDLESS
RED
INDICATOR(**) force device connection
(Aladdin)
Paging
Off
Off
Unlink (Only Bluetooth) Off
GREEN
INDICATOR(**)
Slow blink
Fast blink
Fast blink
Slow blink
304 PowerScan™ PD9530/PBT9500/PM9500
Appendix B
Sample Bar Codes
The sample bar codes in this appendix are typical representations for their symbology types.
1D Bar Codes
UPC-A
EAN-13
978033029095
Code 39
Interleaved 2 of 5
Code 128
Code 128
Product Reference Guide 305
Sample Bar Codes
Sample Bar Codes (continued)
Code 32
Codabar
13579
Code 93
Code 11
123456789
306 PowerScan™ PD9530/PBT9500/PM9500
GS1 DataBar™ (RSS)
GS1 DataBar™ variants must be enabled to read the bar codes below (see " GS1 DataBar™
).
GS1 DataBar™ Expanded Stacked
10293847560192837465019283746029478450366523
GS1 DataBar™ Expanded
1234890hjio9900mnb
GS1 DataBar™ Limited
08672345650916
GS1 DataBar™-14
GS1 DataBar™ Omnidirectional Truncated
55432198673467
GS1 DataBar™ Omnidirectional Stacked
90876523412674
GS1 DataBar™ Omnidirectional Stacked
78123465709811
Product Reference Guide 307
Sample Bar Codes
Aztec
2D Bar Codes
Datamatrix
China Sensible Code
PDF 417
ABCabc
QR Code
35900G9
MaxiCode
Test Message
Micro PDF 417
BV17453
Micro QR Code
123456
UCC Composite
308 PowerScan™ PD9530/PBT9500/PM9500
Appendix C
Standard Defaults
The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming bar codes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features.
Table 55. Standard Defaults
Parameter
GLOBAL INTERFACE FEATURES
RS-232 ONLY
RS-232/USB-Com
Default
Obey
Disable
115200
8 Data Bits
1 Stop Bit
None
RTS
No Delay
Disable
Enable
Disable
‘ACK’
‘NAK’
200 ms
3 Retries
Your Setting
Page
Number
Product Reference Guide 309
Standard Defaults
Parameter Default
KEYBOARD WEDGE
USB-OEM
Ignore Errors Detected
Enable
‘D’
‘E’
U.S. Keyboard
00
100 ms
No Delay
Caps Lock OFF
NumLock Key Unchanged
1 ms
Standard Keys
Handheld
Ignore Scanner Configuration Host Commands
Data Format
Global Prefix/Suffix (Header/Terminator)
Set AIM ID Individually for GS1-128
READING PARAMETERS
No Global Prefix
Global Suffix = 0x0D (CR)
Disable
Enable
EU Set
Disable
Disable
No Char Conversion
0.6 Second
Power-up Beep
After Decode
Mono
High
80 ms
Your Setting
Page
Number
310 PowerScan™ PD9530/PBT9500/PM9500
Parameter
Scanning Features
Stand Mode Illumination Off Time
Multiple Label Reading
Multiple Labels Ordering by Code
Multiple Labels Ordering by Code Length
CODE SELECTION - 1D SYMBOLOGIES
Code EAN/UPC
UPC-A
UPC-A Check Character Transmission
Default
High
300 ms
Trigger Single
Disable
Disable
Medium
2 Seconds
5 Seconds
OFF
10 = Flash is ON for 1
Second
06 = Flash is OFF for
600ms
Enable
Aiming Off
After Decoding
300 ms
Enable
Disable
Disable
Random Order
Disable
Enable only UPCA coupon decoding
Enable
Send
Don’t Expand
Transmit
Your Setting
Page
Number
Product Reference Guide 311
Standard Defaults
Parameter
UPC-E
UPC-E Check Character Transmission
GTIN
EAN 13 (Jan 13)
EAN 13 Check Character Transmission
ISSN
EAN 8
EAN 8 Check Character Transmission
UPC/EAN Global Settings
Add-Ons
Default
2D Component Not
Required
Your Setting
Page
Number
Enable
Send
2D Component Not
Required
Don’t Expand
Don’t Expand
Transmit
Disable
Enable
Send
Transmit
Disable
2D Component Not
Required
Disable
Enable
Send
Disable
2D Component Not
Required
Disable
Two Modules
Disable P2, P5 and P8
70 ms
Disable
312 PowerScan™ PD9530/PBT9500/PM9500
Parameter
Code 39
Code 39 Check Character Calculation
Code 39 Check Character Transmission
Trioptic Code
Code 32 (Italian Pharmaceutical Code)
Code 32 Check Character Transmission
Code 39 CIP (French Pharmaceutical Code)
Special Codes
Code 39 Danish PPT Enable/Disable
Code 39 LaPoste Enable/Disable
Code 128
Code 128 Check Character Transmission
Default
Enable
Calculate Std Check
Send
Don’t Transmit
Disable
Small Quiet Zones on two sides
Variable
2
50
Disable
Disable
Don’t Send
Don’t Transmit
Disable
Disable
Disable
Disable
Enable
Don’t Expand
Don’t Send
Don’t Send
Disable
Small Quiet Zones on two sides
Your Setting
Page
Number
Product Reference Guide 313
Standard Defaults
Parameter
GS1-128
ISBT 128
ISBT 128 Dynamic Concatenation Timeout
Interleaved 2 of 5
I 2 of 5 Check Character Calculation
I 2 of 5 Check Character Transmission
Interleaved 2 of 5 CIP HR
Interleaved 2 of 5 CIP HR Enable/Disable
Follett 2 of 5
Standard 2 of 5
Standard 2 of 5 Enable/Disable
Standard 2 of 5 Check Character
Standard 2 of 5 Check Character
Standard 2 of 5 Length Control
Industrial 2 of 5
Industrial 2 of 5 Enable/Disable
Default
Variable
1
80
Transmit in Code 128
Data Format
Disable
Disable
Disable
Static
200 msec
Disable
Disable
Send
Variable
6
50
Disable
Disable
Disable
Disable
Send
Variable
8
50
Disable
Your Setting
Page
Number
314 PowerScan™ PD9530/PBT9500/PM9500
Parameter
Industrial 2 of 5 Check Character
Industrial 2 of 5 Check Character
Industrial 2 of 5 Length Control
Industrial 2 of 5 Set Length 1
Industrial 2 of 5 Set Length 2
Code IATA
IATA Check Character Transmission
Codabar
Codabar Check Character Calculation
Codabar Check Character Transmission
Codabar Start/Stop Character Set
Codabar Start/Stop Character Match
ABC Codabar
ABC Codabar Concatenation Mode
ABC Codabar Dynamic Concatenation
ABC Codabar Force Concatenation
Code 11
Code 11 Check Character Calculation
Code 11 Check Character Transmission
Default
Disable
Enable
Variable
1
50
Disable
Enable
Disable
Don’t Calculate
Send
Transmit abcd/abcd
Don’t Require Match
Quiet Zones on two sides
Variable
3
50
Disable
Disable
Static
200 msec
Disable
Disable
Check C and K
Send
Variable
Your Setting
Page
Number
Product Reference Guide 315
Standard Defaults
Parameter Default
GS1 DataBar™ Omnidirectional
GS1 DataBar™ Omnidirectional Enable/
GS1 DataBar™ Omnidirectional GS1-128
GS1 DataBar™ Omnidirectional 2D
GS1 DataBar™ Expanded
GS1 DataBar™ Expanded Enable/Disable
GS1 DataBar™ Expanded 2D Component
GS1 DataBar™ Expanded Length Control
GS1 DataBar™ Expanded Set Length 1
GS1 DataBar™ Expanded Set Length 2
GS1 DataBar™ Limited
GS1 DataBar™ Limited Enable/Disable
GS1 DataBar™ Limited 2D Component
Code 93
Code 93 Check Character Calculation
Code 93 Check Character Transmission
MSI
MSI Check Character Calculation
4
50
Disable
Disable
2D component not required
Disable
Disable
2D component not required
Variable
1
74
Disable
Disable
2D component not required
Disable
Enable Check C and K
Enable
Variable
1
50
Small Quiet Zones on two sides
Disable
Enable Mod10
Your Setting
Page
Number
316 PowerScan™ PD9530/PBT9500/PM9500
Parameter Default
MSI Check Character Transmission
Plessey
Plessey Check Character Calculation
Enable
Variable
1
50
Plessey Check Character Transmission
CODE SELECTION - 2D SYMBOLOGIES
2D Normal/Inverse Symbol Control
China Sensible Code Enable / Disable
China Sensible Code Length Control
China Sensible Code Set Length 1
China Sensible Code Set Length 2
Data Matrix Square/Rectangular Style
Data Matrix DPM Decoding Safety
Maxicode Primary Message Transmission
Disable
Enable Plessey std. check char. verification
Enable
Variable
1
50
350msec
Disable
Both
Disable
Enable
Variable
1
Disable
Variable
1
7,827
Enable
Both Square and
Rectangular style
1
Variable
1
3,116
Disable
Disable
Variable
Your Setting
Product Reference Guide
Page
Number
317
Standard Defaults
Parameter
UCC Composite Enable / Disable
Motion Features
Wireless Features
318
Default
1
0145
Enable
Variable
1
2,710
Disable
Micro PDF AIM ID and label type
Variable
1
0366
Enable
Variable
1
7,089
Disable
Variable
0001
0035
Disable
Timer Disabled
Disable all Postal codes
Disable
Your Setting
Page
Number
Enable
Medium
2 seconds
Enable
Low
80 msec
High
PowerScan™ PD9530/PBT9500/PM9500
Parameter Default
Automatic Configuration Update
Copy Configuration to Base Station
Enable
Enable
Disable
Enable
N/A
N/A
Disable
N/A
N/A
No Delay
Unlink Label Required
Source Radio Address Transmission
Do not include
Source Radio Address Delimiter Character
No Delimiter Character
YYMMDD
HHMMSS
YYYY-MM-DD (ISO 8601)
hh:mm:ss (ISO 8601)
Disable
Disable
Features for PBT9500 Models Only
Bluetooth HID Variable PIN Code
Bluetooth HID Send Unknown ASCII Char
Disable
N/A
4-Character
1234
20 ms
N/A
30 minutes
Static
Off
Disable
2
[SERIAL_NUMBER_
SCANNER]
Your Setting
Page
Number
Product Reference Guide 319
Standard Defaults
Parameter
Bluetooth Reconnect Attempt Mode
Features for PM9500 Models Only
Compatibility with PM8500
Compatible Mode System Speed
Base Address Delimiter Character
RS-485 Master Header/Terminator (
RS-485 Network Warning Message
RS-485 Transmission Warning Message
Display and Keyboard Features
Default
Enable
US
02
Ack from cradle
High Speed
Do Not Include
No Delimiter Character
N/A
N/A
N/A
N/A
Disable
Not Transmitted
Not Transmitted
9600
Local echo mode
8 second delay
Disable
Small
All 4 keys enabled
No Actions Configured
No Actions Configured
N/A
N/A
No Header
No Terminator
Your Setting
Page
Number
320 PowerScan™ PD9530/PBT9500/PM9500
Restore Factory Configuration
If you want to restore the Factory Configuration for your imager, scan either the Restore USA Factory Configuration bar code or the Restore EU
Factory Configuration bar code below. Both labels restore the scanner configuration to the factory settings, including the interface type.
CAUTION
Scanning either of the “Restore Factory Configuration” commands below will result in the loss of any custom configuration settings
for your device. Go to "Restore Custom Defaults" on page 18
if you want to restore your custom configuration settings.
The USA label restores Label IDs to those historically used in the USA.
The EU label restores Label IDs to those historically used in Europe. The
Label ID sets for USA and EU are shown in
Label ID: Pre-loaded Sets, starting on page 272
of this manual.
$P,AE,P(CR)
Restore USA Factory Configuration
$P,Ae,P(CR)
Restore EU Factory Configuration
Product Reference Guide 321
Standard Defaults
NOTES
322 PowerScan™ PD9530/PBT9500/PM9500
Appendix D
Keypad
Use the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad.
1
0
2
3
5
4
Product Reference Guide
6
8
7
9
323
Keypad
Keypad (continued)
A
C
E
B
D
F
324 PowerScan™ PD9530/PBT9500/PM9500
Appendix E
Scancode Tables
Control Character Emulation
Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB
Keyboard platforms.
Control Character 00 :
Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Control Character 01 :
Characters from 00 to 0x1F are sent as control character Ctrl+Capital Key, special keys are located from 0x80 to 0xA1.
Control Character 02 :
Special keys are located from 00 to 0x1F and characters from 0x80 to 0xFE are intended as an extended ASCII table
(Microsoft Windows Codepage 1252 — see
).
Single Press and Release Keys
In the following tables, Ar ↓ means Alt right pressed and Ar ↑ means Alt right released and so on. Definitions for other keys are Al (Alt left ), Cr
(Control Right ) Cl (Control Left ) Sh (shift). This method can be used for combining Alt, Control or Shift with other keys.
Example: Consider a Control character set to 00. If AltRight+A is required before sending a label to the host, it could be done by setting three Prefix keys in this way: 0x99 0x41 0x9A.
Product Reference Guide 325
Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE
9x
Ax
Bx
Cx
Dx
Ex
Fx
1x
5x
6x
7x
2x
3x
4x
Table 56. Scancode Set When Control Character is 00 or 01
0x
8x x0
NULL
C+@
DLE
C(S)+P
SP
0
` p
@
P
€
Ð
à
ð
F12
Cr ↑
°
À x1
SOH
C(S)+A
DC1
C(S)+Q
!
1 a q
A
Q
Sh↓
Home
±
Á
á
ñ
Sh↑
Ò
â
ò
End
‘
²
 x2
STX
C(S)+B
DC2
C(S)+R
"
2 b r
B
R
Pg Up
ƒ
³
Ã
Ó
ã
ó x3
ETX
C(S)+C
DC3
C(S)+S
#
3 c s
C
S
Ins
Pg Dwn
„
´
Ä
Ô
ä
ô x4
EOT
C(S)+D
DC4
C(S)+T
$
4 d t
D
T
Ent
(keyp) x5
ENQ
C(S)+E
NAK
C(S)+U
%
5 e u
E
U
F1
Õ
å
õ
µ
Å
…
X6
ACK
C(S)+F
SYN
C(S)+V
&
6 f v
F
V
F2
Ö
æ
ö
¶
Æ
† x7
BEL
C(S)+G
ETB
C(S)+W
'
7 g w
G
W x8
BS
CAN
C(S)+X
(
8 h x
H
X
F3
×
ç
÷
·
Ç
‡
F4
Ø
è
ø
¸
È
ˆ
HT
TAB x9
EM
C(S)+Y
)
9 i y
I
Y
F5
Ù
é
ù
Ar↓
‰
¹
É xA
LF
C(S)+J
SUB
C(S)+Z
*
: j z
J
Z
F6
Ú
ê
ú
Ar↑
Š
º
Ê xC
FF
C(S)+L
FS
C+\
,
<
| l
L
\
F8
Ü
ì
ü
Al↑
Ś
¼
Ì xB
VT
C(S)+K
ESC
Esc
+
; k
{
K
[
F7
Û
ë
û
Al↓
‹
»
Ë xD
CR
Enter
GS
C+]
-
= m
}
M
]
F9
Ý
í
ý
Cl ↓
‹
½
Í xF
SI
C(S)+O
US
C(S)+_
/
?
O
_ o
Del
F11
ï
ÿ
Ï
ß
Cr ↓
¿ xE
SO
C(S)+N
RS
C+^
.
> n
~
N
^
F10
Þ
î
þ
Cl ↑
Œ
¾
Î
Extended characters (sky blue) are sent through dedicated keys (when available in the selected country mode) or by using an
Alt Mode sequence.
326 PowerScan™ PD9530/PBT9500/PM9500
Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE (continued)
Table 57. Scancode Set When Control Character is 02 x0
Ar↓ p
€
P
`
Pg Dwn
Space
0
@
NBSP
°
À
Ð
à
ð
0x
9x
Ax
Bx
Cx
Dx
Ex
Fx
5x
6x
7x
8x
1x
2x
3x
4x x1
Ar↑ x2
Al↓
’
¢
²
Â
Ò
â
ò
‘ r
R b
2
B
“
‘
¡
±
Á q
á
ñ
Home
!
1
A
Q a x3
Al ↑
“
£
³
Ã
Ó
ã
ó s
ƒ
S c
3
C
# x8
BS
¨
˜
¸
È
Ø
è
ø x
ˆ
X h
8
H
F3
( x7
Cr ↑
—
§
·
Ç
×
ç
÷ w
‡
W g
F2
‘
7
G
X6
Cr ↓
–
¦
¶
Æ
Ö
æ
ö v
†
V f
6
F
F1
& x5
Cl ↑
•
¥
µ
Å
Õ
å
õ u
…
U e
5
E
F6
% x4
Cl ↓
”
¤
´
Ä
Ô
ä
ô t
„
T d
4
D
$ x9
Tab
™
©
¹
É
Ù
é
ù y
‰
Y i
9
I
F4
) xA
š
ª
º
Ê
Ú
ê
ú z
Š
Z j
:
J
F5
*
›
«
»
Ë
Û
ë
û xB
S+ Tab
ESC
+ xC
Enter
Keypd
F7
,
[ k
;
K
{
‹
|
Ś l
\
<
L
œ
¬
¼
Ì
Ü
ì
ü xD
Enter
½
Í
-
}
‹
] m
F8
-
=
M
Ý
í
ý xF
Pg Up
Del
Ÿ
¯
¿
Ï
F10
/
?
O
_ o
ß
ï
ÿ xE
Ins ž
®
¾
Î
Þ
î
þ
~
Œ
^ n
>
N
F9
.
Product Reference Guide 327
Interface Type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode
0x
Cx
Dx
Ex
Fx
9x
Ax
Bx
1x
5x
6x
7x
2x
3x
4x
Table 58. Scancode Set When Control Character is 00 or 01
8x x0
Alt+000 x1
Alt+001 x2
Alt+002 x3
Alt+003 x4
Alt+004 x5
Alt+005
X6
Alt+006 x7
Alt+007 x8
BS x9
HT
TAB xA
Alt+010 xB
Alt+011 xC
Alt+012 xD
CR
Enter xE
Alt+014
Xf
Alt+015
Alt+016
A+032
A+048
A+064
A+080
A+096
A+112
€
Alt+017
A+033
A+049
A+065
A+081
A+097
A+113
Sh↓
Alt+018
A+034
A+050
A+066
A+082
A+098
A+114
Sh↑
Alt+019
A+035
A+051
A+067
A+083
A+099
A+115
Ins
Alt+020
A+036
A+052
A+068
A+084
A+100
A+116
Ent
(keyp)
Alt+021
A+037
A+053
A+069
A+085
A+101
A+117
F1
Alt+022
A+038
A+054
A+070
A+086
A+102
A+118
F2
Alt+023
A+039
A+055
A+071
A+087
A+103
A+119
F3
Alt+024
A+040
A+056
A+072
A+088
A+104
A+120
F4
Alt+025
A+041
A+057
A+073
A+089
A+105
A+121
F5
Alt+026
A+042
A+058
A+074
A+090
A+106
A+122
F6
ESC
Esc
A+043
A+059
A+075
A+091
A+107
A+123
F7
Alt+028
A+044
A+060
A+076
A+092
A+108
A+124
F8
Alt+029
A+045
A+061
A+077
A+093
A+109
A+125
F9
Alt+030
A+046
A+062
A+078
A+094
A+110
A+126
F10
Alt+031
A+047
A+063
A+079
A+095
A+111
A+127
F11
F12
Cr ↑
Home End Pg Up Pg Dwn Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓
A+0161 A+0162 A+0163 A+0164 A+0165 A+0166 A+0167 A+0168 A+0169 A+0170 A+0171 A+0172 A+0173 A+0174 A+0175
A+0176 A+0177 A+0178 A+0179 A+0180 A+0181 A+0182 A+0183 A+0184 A+0185 A+0186 A+0187 A+0188 A+0189 A+0190 A+0191
A+0192 A+0193 A+0194 A+0195 A+0196 A+0197 A+0198 A+0199 A+0200 A+0201 A+0202 A+0203 A+0204 A+0205 A+0206 A+0207
A+0208 A+0209 A+0210 A+0211 A+0212 A+0213 A+0214 A+0215 A+0216 A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223
A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239
A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255
328 PowerScan™ PD9530/PBT9500/PM9500
Interface Type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode (continued)
0x
Dx
Ex
Fx
9x
Ax
Bx
Cx
5x
6x
7x
8x
1x
2x
3x
4x
Table 59. Scancode Set When Control Character is 02 x0
Ar↓
Pg Dwn
A+032
A+048
A+064
A+080
A+096 x1
Ar↑
Home
A+033
A+049
A+065
A+081
A+097 x2
Al↓
A+034
A+050
A+066
A+082
A+098 x3
Al ↑
A+035
A+051
A+067
A+083
A+099 x4
Cl ↓
A+036
A+052
A+068
A+084
A+100 x5
Cl ↑
F6
A+037
A+053
A+069
A+085
A+101
X6
Cr ↓
F1
A+038
A+054
A+070
A+086
A+102 x7
Cr ↑
F2
A+039
A+055
A+071
A+087
A+103 x8
BS
F3
A+040
A+056
A+072
A+088
A+104 x9
Tab
F4
A+041
A+057
A+073
A+089
A+105 xA
F5
A+042
A+058
A+074
A+090
A+106 xB
S+ Tab
ESC xC
Enter
Keypd
F7
A+043
A+059
A+075
A+091
A+107
A+044
A+060
A+076
A+092
A+108 xD
Enter
F8
A+045
A+061
A+077
A+093
A+109 xE
Ins
F9
A+046
A+062
A+078
A+094
A+110 xF
Pg Up
F10
A+047
A+063
A+079
A+095
A+111
A+112 A+113 A+114 A+115 A+116 A+117 A+118 A+119 A+120 A+121 A+122 A+123 A+124 A+125 A+126 A+127
A+0128 A+0129 A+0130 A+0131 A+0132 A+0133 A+0134 A+0135 A+0136 A+0137 A+0138 A+0139 A+0140 A+0141 A+0142 A+0143
A+0144 A+0145 A+0146 A+0147 A+0148 A+0149 A+0150 A+0151 A+0152 A+0153 A+0154 A+0155 A+0156 A+0157 A+0158 A+0159
A+0160 A+0161 A+0162 A+0163 A+0164 A+0165 A+0166 A+0167 A+0168 A+0169 A+0170 A+0171 A+0172 A+0173 A+0174 A+0175
A+0176 A+0177 A+0178 A+0179 A+0180 A+0181 A+0182 A+0183 A+0184 A+0185 A+0186 A+0187 A+0188 A+0189 A+0190 A+0191
A+0192 A+0193 A+0194 A+0195 A+0196 A+0197 A+0198 A+0199 A+0200 A+0201 A+0202 A+0203 A+0204 A+0205 A+0206 A+0207
A+0208 A+0209 A+0210 A+0211 A+0212 A+0213 A+0214 A+0215 A+0216 A+0217 A+0218 A+0219 A+0220 A+0221 A+0222 A+0223
A+0224 A+0225 A+0226 A+0227 A+0228 A+0229 A+0230 A+0231 A+0232 A+0233 A+0234 A+0235 A+0236 A+0237 A+0238 A+0239
A+0240 A+0241 A+0242 A+0243 A+0244 A+0245 A+0246 A+0247 A+0248 A+0249 A+0250 A+0251 A+052 A+0253 A+0254 A+0255
Product Reference Guide 329
Digital Interface
1x
5x
6x
7x
2x
3x
4x
Table 60. Scancode Set When Control Character is 00 or 01
0x
8x
9x
X0
NULL
C+@
DLE
C(S)+P
Space
0
` p
@
P
F12 x1
SOH
C(S)+A
DC1
C(S)+Q
!
1 a q
A
Q
Sh↓
F13 x2
STX
C(S)+B
DC2
C(S)+R
“
2 b r
B
R
Sh↑
F14 x3
ETX
C(S)+C
DC3
C(S)+S
#
3 c s
C
S
Ins
F15 x4
EOT
C+D
DC4
C(S)+T
$
4 d t
D
T
Ent
(keyp)
F16 x5
ENQ
C(S)+E
NAK
C(S)+U
%
5 e u
E
U
F1
x6
ACK
C(S)+F
SYN
C(S)+V
&
6 f v
F
V x7
BEL
C(S)+G
ETB
C(S)+W
‘
7 g w
G
W x8
BS
CAN
C(S)+X
(
8 h x
H
X
F2
F3
F4
HT
TAB x9
EM
C(S)+Y
)
9 i y
I
Y
F5 xA
LF
C(S)+J
SUB
C(S)+Z
*
: j z
J
Z
F6 xB
VT
C(S)+K
ESC
Esc
+
; k
{
K
[
F7 xC
FF
C(S)+L
FS
C(S)+\
,
<
| l
L
\
F8 xD
CR
Enter
GS
C+]
-
= m
}
M
]
F9
Cl ↓ xE
SO
C(S)+N
RS
C(S)+^
.
> n
~
N
^
F10
Cl ↑ xF
SI
C(S)+O
US
C(S)+_
/
?
O
_ o
Del
F11
Table 61. Scancode Set When Control Character is 02
X0 x1 x2 x3
0x
4x
5x
6x
7x
1x
2x
3x
Space
0
@
P
` p
A
Q
!
1 a q b r
B
R
“
2 c s
C
S
#
3 x4
Cl ↓ d t
D
T
$
4 x5
Cl ↑ e u
E
U
F6
%
5 x6 f v
F
V
F1
&
6
330 x7 g w
G
W
F2
‘
7 x8
BS h x
H
X
F3
(
8 x9
Tab i y
I
Y
F4
)
9 xA
à j z
J
Z
F5
*
: xB
S+ Tab k
{
K
[
ESC
+
;
L
\
,
< xC
Enter
Keypd
F7
| l xD
Enter m
}
M
]
F8
-
= xE
Ins n
~
N
^
F9
.
> xF
F10
?
/
O
_ o
Del
PowerScan™ PD9530/PBT9500/PM9500
IBM31xx 102-key
1x
5x
6x
7x
2x
3x
4x
Table 62. Scancode Set When Control Character is 00 or 01
0x
8x
X0
NULL
C+@
DLE
C(S)+P
Space
0
‘ p
@
P x1
SOH
C(S)+A
DC1
C(S)+Q
!
1 a q
A
Q
Sh↓ x2
STX
C(S)+B
DC2
C(S)+R
“
2
B
R
B
R
Sh↑ x3
ETX
C(S)+C
DC3
C(S)+S
#
3 c s
C
S
Ins x4
EOT
C+D
DC4
C(S)+T
$
4 d t
D
T
Ent
(keyp) x5
ENQ
C(S)+E
NAK
C(S)+U
%
5 e u
E
U
F1
9x
Ax
F12
Cr ↑
Enter Reset Insert Delete Field x6
ACK
C(S)+F
SYN
C(S)+V
&
6 f v
F
V
F2
Field + x7
BEL
C(S)+G
ETB
C(S)+W
‘
7 g w
G
W x8
BS
CAN
C(S)+X
(
8 h x
H
X
F4 F3
Enter paddle
Printl
HT
TAB x9
EM
C(S)+Y
)
9 i y
I
Y
F5 xA
LF
C(S)+J
SUB
C(S)+Z
*
: j z
J
Z
F6
Ar↓ Ar↑ xB
VT
C(S)+K
ESC
Esc
+
; k
{
K
[
F7 xC
FF
C(S)+L
FS
C(S)+\
,
<
| l
L
\
F8 xD
CR
Enter
GS
C+]
-
= m
}
M
]
F9
Al↓ Al ↑ Cl ↓ xE
SO
C(S)+N
RS
C(S)+^
.
>
N
^ n
F10 xF
SI
C(S)+O
US
C(S)+_
/
?
O
_ o
Del
F11
Cl ↑ Cr ↓
Table 63. Scancode Set When Control Character is 02
0x
4x
5x
6x
7x
1x
2x
3x
X0
Ar↓
Pg Dwn
Space
0
@
P
‘ p x1
Ar↑
Home
!
1
A
Q a q x2
Al↓
R
B
2
B
R
“ x3
Al ↑
S c
3
C s
# x4
Cl ↓
T d
4
D t
$
Product Reference Guide x5
Cl ↑
U e u
5
E
F6
% x6
Cr ↓
V f v
6
F
F1
& x7
Cr ↑
W g w
F2
‘
7
G x8
BS
X h x
8
H
F3
( x9
Tab
Y i y
9
I
F4
) xA
Z j z
:
J
F5
* xB
S+ Tab
[ k
{
ESC
+
;
K l
\
<
L
| xC
Enter
Keypd
F7
, xD
Enter
] m
}
F8
-
=
M xE
Ins
>
N
F9
.
^ n xF
Pg Up
F10
/
?
O
_ o
Del
331
IBM XT
1x
5x
6x
7x
2x
3x
4x
Table 64. Scancode Set When Control Character is 00 or 01
0x
8x
9x
Ax
X0
NULL
C+@
DLE
C(S)+P
Space
0
‘ p
@
P
F12
Cr ↑ x1
SOH
C(S)+A
DC1
C(S)+Q
!
1 a q
A
Q
Sh↓
Home x2
STX
C(S)+B
DC2
C(S)+R
“
2
B
R
B
R
Sh↑
End x3
ETX
C(S)+C
DC3
C(S)+S
#
3 c s
C
S
Ins
Pg Up x4
EOT
C+D
DC4
C(S)+T
$
4 d t
D
T
Ent
(keyp)
Pg Dwn x5
ENQ
C(S)+E
NAK
C(S)+U
%
5 e u
E
U
F1
x6
ACK
C(S)+F
SYN
C(S)+V
&
6 f v
F
V x7
BEL
C(S)+G
ETB
C(S)+W
‘
7 g w
G
W x8
BS
C(S)+H
CAN
C(S)+X
(
8 h x
H
X
F2
F3
F4
HT
TAB x9
EM
C(S)+Y
)
9 i y
I
Y xA
LF
C(S)+J
SUB
C(S)+Z
*
: j z
J
Z
F5
Ar↓
F6
Ar↑ xB
VT
C(S)+K
ESC
Esc
+
; k
{
K
[ xC
FF
C(S)+L
FS
C(S)+\
,
<
| l
L
\
F7
Al↓
F8
Al ↑ xD
CR
Enter
GS
C+]
-
= m
}
M
]
F9
Cl ↓ xE
SO
C(S)+N
RS
C(S)+^
.
>
N
^ n
F10
Cl ↑ xF
SI
C(S)+O
US
C(S)+_
/
?
O
_ o
Del
F11
Cr ↓
Table 65. Scancode Set when Control Character 02
0x
X0
Ar↓ x1
Ar↑ x2
Al↓ x3
Al ↑
5x
6x
7x
1x
2x
3x
4x
Pg Dwn
Space
0
@
P
‘ p
Home
!
1
A
Q a q
R
B
R
“
2
B
S c s
#
3
C
332 x4
Cl ↓
T d t
$
4
D x5
Cl ↑
U e u
5
E
F6
% x6
Cr ↓
V f v
6
F
F1
& x7
Cr ↑
W g w
F2
‘
7
G x8
BS
X h x
8
H
F3
( x9
Tab
Y i y
9
I
F4
) xA
Z j z
:
J
F5
* xB
S+ Tab
[ k
{
ESC
+
;
K l
\
<
L
| xC
Enter
Keypd
F7
, xD
Enter
] m
}
F8
-
=
M xE
Ins
>
N
F9
.
^ n xF
Pg Up
F10
/
?
O
_ o
Del
PowerScan™ PD9530/PBT9500/PM9500
Microsoft Windows Codepage 1252
Microsoft Windows Codepage 1252
Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages.
Product Reference Guide 333
Scancode Tables
NOTES
334 PowerScan™ PD9530/PBT9500/PM9500
ASCII Chart
ASCII
Char.
CAN
EM
SUB
ESC
FS
GS
RS
US
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
FF
CR
SO
SI
BS
HT
LF
VT
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
ASCII
Char.
>
?
<
=
;
:
8
9
6
7
4
5
2
3
0
1
.
/
,
-
*
+
)
(
&
’
$
%
SP
!
“
#
Hex
No.
1C
1D
1E
1F
18
19
1A
1B
14
15
16
17
10
11
12
13
0C
0D
0E
0F
08
09
0A
0B
04
05
06
07
00
01
02
03
ASCII
Char.
^
_
\
]
Z
[
X
Y
T
U
V
W
R
S
P
Q
L
M
N
O
H
I
J
K
D
E
F
G
@
A
B
C
Hex
No.
3C
3D
3E
3F
38
39
3A
3B
34
35
36
37
30
31
32
33
2C
2D
2E
2F
28
29
2A
2B
24
25
26
27
20
21
22
23
ASCII
Char.
|
}
~
DEL z
{ x y v w t u r s p q l m n o j k h i f g d e b c
‘ a
Hex
No.
5C
5D
5E
5F
58
59
5A
5B
54
55
56
57
50
51
52
53
4C
4D
4E
4F
48
49
4A
4B
44
45
46
47
40
41
42
43
Hex
No.
7C
7D
7E
7F
78
79
7A
7B
74
75
76
77
70
71
72
73
6C
6D
6E
6F
68
69
6A
6B
64
65
66
67
60
61
62
63
www.datalogic.com
©2013 Datalogic, Inc. All rights reserved. Datalogic and the Datalogic
logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U.
Datalogic ADC, Inc.
959 Terry Street | Eugene | OR 97402 | USA
Telephone: (1) 541-683-5700 | Fax: (1) 541-345-7140
820053614
(Rev C) November 2013
ดาวน์โหลด