- No category
N1040 Controller TEMPERATURE CONTROLLER – INSTRUCTIONS MANUAL – V1.1x A SAFETY ALERTS
Add to my manuals
5 Pages
advertisement
▼
Scroll to page 2
of 5
N1040 Controller TEMPERATURE CONTROLLER – INSTRUCTIONS MANUAL – V1.1x A RECOMMENDATIONS FOR THE INSTALLATION SAFETY ALERTS The symbols below are used on the equipment and throughout this document to draw the user’s attention to important operational and safety information. CAUTION: Read the manual thoroughly before installing and operating the equipment. CAUTION OR DANGER: Electrical shock hazard All safety related instructions that appear in the manual must be observed to ensure personal safety and to prevent damage to either the instrument or the system. If the instrument is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. INSTALLATION / CONECTIONS The controller must be fastened on a panel, following the sequence of steps described below: • Prepare a panel cut-out of 46 x 46 mm; • Remove the mounting clamps from the controller; • Insert the controller into the panel cut-out; • Slide the mounting clamp from the rear to a firm grip at the panel. ELECTRICAL CONNECTIONS • All electrical connections are made to the screw terminals at the rear of the controller. • To minimize the pick-up of electrical noise, the low voltage DC connections and the sensor input wiring should be routed away from high-current power conductors. If this is impractical, use shielded cables. In general, keep cable lengths to a minimum. • All electronic instruments must be powered by a clean mains supply, proper for instrumentation. • It is strongly recommended to apply RC'S FILTERS (noise suppressor) to contactor coils, solenoids, etc. In any application it is essential to consider what can happen when any part of the system fails. The controller features by themselves can not assure total protection. FEATURES INPUT TYPE SELECTION Table 01 shows the sensor types accepted and their respective codes and ranges. Access the parameter TYPE in the INPUT cycle to select the appropriate sensor. TYPE CODE Thermocouple J Tc j Range: -110 to 950 ºC (-166 to 1742 ºF) RANGE OF MEASUREMENT Thermocouple K Tc k Range: -150 to 1370 ºC (-238 to 2498 ºF) Thermocouple T Tc t Range: -160 to 400 ºC (-256 to 752 ºF) Pt100 Pt Range: -200 to 850 ºC (-328 to 1562 ºF) Table 01 – Input types Figure 01 below shows the electrical terminals of the controller: OUTPUTS The controller offers two, three or four output channels, depending on the loaded optional features. The output channels are user configurable as Control Output, Alarm 1 Output, Alarm 2 Output, Alarm 1 OR Alarm 2 Output and LBD (Loop Break Detect) Output. OUT1 - Logical pulse, 5 Vdc / 20 mA, available at terminals 4 and 5. OUT2 - Relay SPST-NA, 3 A / 250 Vac, available at terminals 6 and 7. OUT3 - Relay SPST-NA, 3 A / 240 Vac, available at terminals 13 and 14. OUT4 - Relay SPDT, available at terminals 10, 11 and 12. CONTROL OUTPUT Figure 01 - Connections of the back panel NOVUS AUTOMATION The control strategy can be ON/OFF (when PB = 0.0) or PID. The PID parameters can be automatically determined enabling the autotuning function (ATvN ATvN). ATvN 1/5 N1040 Controller ALARM OUTPUT The controller contains 2 alarms that can be directed (assigned) to any output channel. The alarm functions are described in Table 02. off Output is not used as alarm. lo Alarm of Absolute Minimum Value. Triggers when the value of measured PV is below the value defined for alarm Setpoint. ki Alarm of Absolute Maximum Value. Triggers when the value of measured PV is above the value defined for alarm Setpoint. PV SPA1 PV SPA1 Alarm of Differential Value. In this function the parameters SPA1 and SPA2 represent the deviation of PV in relation to the SP of CONTROL. dif PV PV SP – SPA1 SP SP + SPA1 SV + SPA1 alarme Positive SPA1 SP SV – SPA1 SAFE OUTPUT VALUE WITH SENSOR FAILURE This function defines an output value (user defined) to be assigned to the control output in the event of a sensor failure. When the input sensor is identified as broken, the controller switches the control mode to MANUAL while forcing MV to assume the user configured value in the 1E.ov parameter. This function requires that one of the alarms be configured as 1Err and the 1E.ov parameter (control output percentage) programmed with a value other then 0 (zero). Once this function is triggered, the controller remains in SAFE mode (MANUAL control output) even after the sensor failure appears to be fixed. The operator intervention is required for switching back to AUTO mode. 1E.ov values are only 0 and 100 % when in ON/OFF control mode. For PID control mode any value in the range from 0 to 100 % is accepted. Negative SPA1 Alarm of Minimum Differential Value. It triggers when the value of PV is below the defined point by (using the Alarm 1 as example). difl A LBD event may be sent to any output channel. Simply configure the LDB function to the desired output channel (OUT1 or OUT2): the selected output will be activated when a LDB condition is detected. When the Lbd.t parameter is programmed with 0 (zero), the LDB function is disabled. The LBD is useful in detecting system failures, such us defective sensors or actuators, loads and power supply, among others. The controller’s front panel, with its parts, can be seen in the Figure 02: PV PV SP – SPA1 OPERATION SP SP Positive SPA1 SP – SPA1 Negative SPA1 Alarm of Valor Maximum Differential Value. Triggers when the value of PV is above the defined point by (using Alarm 1 as example): difk PV PV SP SP + SPA1 SP + SPA1 Positive SPA1 ierr SP Negative SPA1 Sensor Break Alarm. Activated when the input signal of PV is interrupted, out of the range limits or Pt100 in short-circuit. Table 02 – Alarm functions Figure 02 - Identification of the parts referring to the front panel Display of PV / Programming (top display, red color): Displays the current value of PV (Process Variable). When in configuration mode, it shows the parameters names. Display of SP / Parameters (bottom display, green color): Displays the value of SP (Setpoint). When in configuration mode, it shows the parameters values. TUNE Indicator: Stays ON while the controller is in tuning process. Note: Alarm functions on Table 02 are also valid for Alarm 2 (SPA2). OUT Indicator: For relay or pulse control output; it reflects the actual state of the output. INITIAL BLOCKING OF ALARM A1 and A2 Indicators: signalize the occurrence of alarm situation. The initial blocking option inhibits the alarm from being recognized if an alarm condition is present when the controller is first energized (or after a transition from run YES NO). The alarm will be enabled only after the occurrence of a non alarm condition followed by a new occurrence for the alarm. The initial blocking is useful, for instance, when one of the alarms is configured as a minimum value alarm, causing the activation of the alarm soon upon the process start-up, an occurrence that may be undesirable. The initial blocking is disabled for the sensor break alarm function. P Key: used to walk through the menu parameters. OFFSET Allows fine adjustments to the PV reading for compensation of sensor error. FUNÇÃO LBD – LOOP BREAK DETECTION The parameter defines a time interval, in minutes, within which the PV is expect to react to a control output signal. If the PV does not react properly within the time interval configured in lbd.t, the controller interprets this as a control loop break and signals this occurrence in the display. NOVUS AUTOMATION Increment key and values of the parameters. - Decrement key: allow altering the Back key: used to retrocede parameters. OPERATION When the controller is powered up, it displays its firmware version for 3 seconds, after which the controller starts normal operation. The value of PV and SP is then displayed and the outputs are enabled. In order for the controller to operate properly in a process, its parameters need to be configured first, such that it can perform accordingly to the system requirements. The user must be aware of the importance of each parameter and for each one determine a valid condition. The parameters are grouped in levels according to their functionality and operation easiness. The 5 levels of parameters are: 1 – Operation / 2 – Tuning / 3 – Alarms / 4 – Input / 5 – Calibration The “P” key is used for accessing the parameters within a level. 2/5 N1040 Controller Keeping the “P” key pressed, at every 2 seconds the controller jumps to the next level of parameters, showing the first parameter of each level: PV >> atvn >> fva1 >> type >> pass >> PV … To enter a particular level, simply release the “P” key when the first parameter in that level is displayed. To walk through the parameters in a level, press the “P” key with short strokes. To go back to the previous parameter in a cycle, press : Each parameter is displayed with its prompt in the upper display and value/condition in the lower display. Depending on the level of parameter protection adopted, the parameter PASS precedes the first parameter in the level where the protection becomes active. See section CONFIGURATION PROTECTION. sfst SoftStart function – Time in seconds during which the controller limits the MV value progressively from 0 to 100 %. It is enabled at power up or when the control output is activated. If in doubt set sfst = 0 (the zero value disables the Soft start function). 0vt1 0vt2 0vt3 0vt4 Assign functions to the Output channels OUT1, OUT2, OUT3 e OUT4: Off - Not used. (trl(trl control output. A1 - alarm 1 output. A2 - alarm 2 output. A1a2 - Alarm 1 + Alarm2 (OR logic). Lbd - Loop Break Detect Alarm. DESCRIPTION OF THE PARAMETERS OPERATION CYCLE PV + SP PV and SP indication – The upper display shows the current value of PV. The lower display shows the control SP value. Sp.a1 Sp.a2 ALARM SETPOINT: Tripping point for alarm 1 and 2. Value that defines the point of activation for the programmed alarms with the functions Lo or ki. ki For the alarms configured with Differential type functions, this parameter defines deviation (band). Not used for the other alarm functions. pb Fva1 Fva2 Functions of Alarms. Defines the functions for the alarms among the options of the Table 02. Sp.a1 Sp.a2 ALARM SETPOINT: Tripping point for alarm 1 and 2. Value that defines the point of activation for the programmed alarms with the functions Lo or ki. ki For the alarms configured with Differential type functions, this parameter defines deviation (band). Not used for the other alarm functions. Sp1.e sp2.e TUNING CYCLE Atvn ALARMS CYCLE AUTO-TUNE: enables the auto-tuning function for the PID parameters (pb pb,ir pb ir, ir dt). dt Defines the control strategy to be taken: off – Turned off. (no PID tuning) Fast – Fast automatic tuning. Full – More accurate automatic tuning. bla1 bla2 Blocking Alarms. YES - enables initial blocking NO - inhibits initial blocking Refer to the section DETERMINATION OF PID PARAMETERS for more details. xya1 xya2 Proportional Band - Value of the term P of the control mode PID, in percentage of the maximum span of the input type. Adjust of between 0 and 500.0 %. Alarm Hysteresis. Defines the difference between the value of PV at witch the alarm is triggered and the value at witch it is turned off. flsh Allows visual signalization of an alarm occurrence by flashing the indication of PV in the operation level. YES - enables alarm signaling flashing PV NO - disables alarm signaling flashing PV When set to zero (0), control action is ON/OFF. ir Configures display of SPA1 and SPA2 also in the Operation Cycle. YES - SPA1/SPA2 are displayed in the Operation Cycle NO - SPA1/SPA2 are not displayed in the Operation Cycle Integral Rate - Value of the term I of the PID algorithm, in repetitions per minute (Reset). Adjustable between 0 and 99.99. Displayed only if proportional band ≠ 0. INPUT CYCLE dt Derivative Time - Value of the term D of the control mode PID, in seconds. Adjustable between 0 and 300.0 seconds. Displayed only if proportional band ≠ 0. Type INPUT TYPE: Selects the input signal type to be connected to the process variable input. Refer to Table 01 for the available options. (t CYCLE TIME: Pulse Width Modulation (PWM) period in seconds. This term is not used when controller is set to ON/OFF action (Pb=0). fltr Kyst yst CONTROL HYSTERESIS: Is the hysteresis for ON/OFF control (set in temperature units). This parameter is only used when the controller is in ON/OFF mode (Pb=0). Digital Input Filter - Used to improve the stability of the measured signal (PV). Adjustable between 0 and 20. In 0 (zero) it means filter turned off and 20 means maximum filter. The higher the filter value, the slower is the response of the measured value. Dp.po Selects the decimal point position to be viewed in both PV and SP. Action Control: vni vni t Selects display indication for degrees Celsius or A(t re Fahrenheit: ( - Indication in Celsius. f - Indication in Fahrenheit. Control with Reverse Action. Appropriate for heating. Turns control output on when PV is below SP. dir Control with Direct Action. Appropriate for cooling. Turns control output on when PV is above SP. 0ffs SENSOR OFFSET: Offset value to be added to the PV reading to compensate sensor error. Default value: zero. Spll Defines the SP lower limit of. To 50 mV input type sets the lower range for SP and PV indication. NOVUS AUTOMATION 3/5 N1040 Controller Spxl Defines the upper limit for adjustment of SP. To 50 mV input type sets the upper range for SP and PV indication. The Access Password is defined by the user in the parameter Password Change (PAS PAS. PAS.(), present in the Calibration Level. The factory default for the password code is 1111. Lbd.t Time interval for the LBD function. Defines the maximum interval of time for the PV to react to a control command. In minutes. 1e.ov Percentage output value that will be transfer to MV when the SAFE output function is enabled. If 1eov = 0, the SAFE output function is disabled and the outputs are turned off in the occurrence of a sensor fail. PROTECTION ACCESS PASSWORD The protection system built into the controller blocks for 10 minutes the access to protected parameters after 5 consecutive frustrated attempts of guessing the correct password. CALIBRATION CYCLE All of the input and output types are calibrated in the factory. If a recalibration is required, this should be carried out by a experienced personnel. If this cycle is accidentally accessed, pass or keys. through all the parameters without pressing the pass Password. This parameter is presented before the protected cycles. See item Protection of Configuration. (alib Enables or disables instrument calibration by the user, YES: YES shows calibration parameters No: No Hides the calibration parameters. inL( Input Low Calibration. Enter the value corresponding to the low scale signal applied to the analog input. ink( Input High Calibration. Enter the value corresponding to the full scale signal applied to the analog input. rstr Restore. Restores the factory calibration for all inputs and outputs, disregarding modifications carried out by the user. (j Cold Junction. This screen is for information purpose only. Pas.( Password Change. Allows defining a new access password, always different from zero. Prot Protection. Sets up the Level of Protection. See Table 05. Freq Mains frequency. This parameter is important for proper noise filtering. CONFIGURATION PROTECTION The controller provides means for protecting the parameters configurations, not allowing modifications to the parameters values, avoiding tampering or improper manipulation. The parameter Protection (PROt PROt), PROt in the Calibration level, determines the protection strategy, limiting the access to particular levels, as shown by the Table 04. Protection Level 1 2 3 4 5 6 Protection Levels Only the Calibration level is protected. Calibration and Input levels. Calibration, Input and Alarms levels. Calibration, Input, Alarms and Tuning levels. All levels are protected, but the SP screen in the operation level. All levels are protected, including SP. MASTER PASSWORD The Master Password is intended for allowing the user to define a new password in the event of it being forgotten. The Master Password doesn’t grant access to all parameters, only to the Password Change parameter (PAS( PAS(). PAS( After defining the new password, the protected parameters may be accessed (and modified) using this new password. The master password is made up by the last three digits of the serial number of the controller added to the number 9000. As an example, for the equipment with serial number 07154321, the master password is 9 3 2 1. Controller serial number is displayed by pressing for 3 seconds. DETERMINATION OF PID PARAMETERS During the process of determining automatically the PID parameters, the system is controlled in ON/OFF in the programmed Setpoint. The auto-tuning process may take several minutes to be completed, depending on the system. The steps for executing the PID autotuning are: • Select the process Setpoint. • Enable auto-tuning at the parameter “Atvn Atvn”, Atvn selecting FAST FAST or FULL. FULL The option FAST performs the tuning in the minimum possible time, while the option FULL gives priority to accuracy over the speed. The sign TUNE remains lit during the whole tuning phase. The user must wait for the tuning to be completed before using the controller. During auto tuning period the controller will impose oscillations to the process. PV will oscillate around the programmed set point and controller output will switch on and off many times. If the tuning does not result in a satisfactory control, refer to Table 05 for guidelines on how to correct the behavior of the process. PARAMETER Band Proportional Rate Integration Derivative Time VERIFIED PROBLEM SOLUTION Slow answer Decrease Great oscillation Increase Slow answer Increase Great oscillation Decrease Slow answer or instability Decrease Great oscillation Increase Table 05 - Guidance for manual adjustment of the PID parameters For further details on PID tuning, visit our web site: Table 04 – Levels of Protection for the Configuration ACESS PASSWORD The protected levels, when accessed, request the user to provide the Access Password for granting permission to change the configuration of the parameters on these levels. The prompt PASS precedes the parameters on the protected levels. If no password is entered, the parameters of the protected levels can only be visualized. NOVUS AUTOMATION 4/5 N1040 Controller MAINTENANCE WARRANTY PROBLEMS WITH THE CONTROLLER Connection errors and inadequate programming are the most common errors found during the controller operation. A final revision may avoid loss of time and damages. The controller displays some messages to help the user identify problems. MESSAGE Warranty conditions are available on our web site . DESCRIPTION OF THE PROBLEM ---- Open input. No sensor or signal. Err1 Err6 Connection and/or configuration problems. Check the wiring and the configuration. Other error messages may indicate hardware problems requiring maintenance service. When contacting the manufacturer, inform the for more instrument serial number, obtained by pressing the key than 3 seconds. PROCESS VARIABLE INPUT CALIBRATION Visit our web site for further information . PART NUMBER FORMATION N1040 – PR Basic version; two outputs: OUT1= logical pulse / OUT2= relay N1040 – PRR Three outputs: OUT1= logical pulse / OUT2 and OUT3 = relay N1040 – PRRR Four outputs: OUT1= logical pulse / OUT2, OUT3 and OUT4= relay SPECIFICATIONS DIMENSIONS:............................................................48 x 48 x 80 mm Approximate:............................................................................75 g POWER SUPPLY:..........................100 to 240 Vac (±10 %), 50/60 Hz ................................................................... 24 to 300 Vdc (±10 %) Maximum consumption:......................................................... 5 VA ENVIRONMENTAL CONDITIONS: Operation Temperature: ................................................ 0 to 60 ºC Relative Humidity:....................................................80 % @ 30 ºC ................ For temperatures above 30 ºC, reduce 3 % for each ºC .......Internal use; Category of installation II, Degree of pollution 2; altitude < 2000 meters INPUT.......Thermocouples J; K; T and Pt100 (according of Table 01) Internal Resolution:...................................... 32767 levels (15 bits) Resolution of Display:..........12000 levels (from -1999 up to 9999) Rate of input reading: .........................................up 55 per second Precision: ........Thermocouples J, K, T: 0.25 % of the span ±1 ºC ................................................................ Pt100: 0.2 % of the span Input Impedance:..................Pt100 and thermocouples: > 10 MΩ Measurement of Pt100: ..........................3-wire type, (α=0.00385) With compensation for cable length, excitation current of 0.170 mA. OUT1: .........................................................Voltage pulse, 5 V / 25 mA OUT2: ..................................................... Relay SPST; 1.5 A / 240 Vac OUT3: ..................................................... Relay SPST; 1.5 A / 240 Vac OUT4: ........................................................ Relay SPDT; 3 A / 240 Vac CASE: ..........................................IP65, Polycarbonate (PC) UL94 V-2 STARTS UP OPERATION AFTER 3 SECONDS CONNECTED TO THE POWER SUPPLY; CERTIFICATION: NOVUS AUTOMATION 5/5
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement