INSTEON On/Off Micro Module Owner's Manual


Add to my manuals
21 Pages

advertisement

INSTEON On/Off Micro Module Owner's Manual | Manualzz

Micro On/Off

Owner’s Manual

2443-222 (US)

2443-422 (EU)

2443-522 (AUS/NZ)

North America

EU/AUS/NZ

Page 1 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

About Micro On/Off ................................................................................................................................... 3

Features and Benefits ............................................................................................................................. 3

Before Installation ..................................................................................................................................... 3

Identifying the Electrical Wires in Your Home (North America only) ........................................................ 4

Identifying the Electrical Wires in Your Home (Europe/Australia/New Zealand) ...................................... 4

Identify Switch Type ................................................................................................................................ 4

Installation ................................................................................................................................................. 5

Switch Operation Mode ............................................................................................................................ 6

Change to Single Momentary Mode ........................................................................................................ 6

Change to Dual Momentary Mode ........................................................................................................... 6

Change to Latching Mode (default) ......................................................................................................... 6

3-Way Toggle Mode (Latching Switches Only, Default)......................................................................... 7

Local Control Operation ........................................................................................................................... 7

Latching Wall Switch (Default) ................................................................................................................. 7

Single Momentary Switch ........................................................................................................................ 8

Dual Momentary Switch........................................................................................................................... 8

Adjust Local Settings ............................................................................................................................... 8

Change LED Brightness (or turn it off)..................................................................................................... 8

Error Blink ................................................................................................................................................ 8

Blink on Traffic ......................................................................................................................................... 9

Beep on Button Press.............................................................................................................................. 9

Programming Lock .................................................................................................................................. 9

INSTEON Setup ......................................................................................................................................... 9

INSTEON Controllers, Responders and Links ......................................................................................... 9

Configure INSTEON Settings .................................................................................................................. 9

Make Micro Module a Responder (Set button) ........................................................................................ 9

Make Micro Module a Responder (Switch) ............................................................................................ 10

Make Micro Module a Controller (Set button) ........................................................................................ 10

Make Micro Module a Controller (Switch) .............................................................................................. 10

Groups................................................................................................................................................... 11

Scenes .................................................................................................................................................. 11

Make Micro Module a Controller of Multiple Responders ...................................................................... 11

Remove Micro Module as a Controller .................................................................................................. 12

Remove Micro Module as a Responder ................................................................................................ 12

Remove Micro Module as a Controller of Multiple Responders ............................................................. 12

Factory Reset ........................................................................................................................................ 12

X10 Setup................................................................................................................................................. 13

Add X10 Address .................................................................................................................................. 13

Remove X10 Address............................................................................................................................ 13

Specifications .......................................................................................................................................... 14

Troubleshooting ...................................................................................................................................... 17

Stuck/Disabled Button ........................................................................................................................... 18

Phase Bridge Detect Beacon/RF Range Test ....................................................................................... 19

Certification and Warranty ..................................................................................................................... 20

Certification ........................................................................................................................................... 20

FCC and Industry Canada Compliance Statement ................................................................................ 20

Declaration of Conformity ...................................................................................................................... 20

ETL/UL Warning (Safety Warning) ........................................................................................................ 20

Limited Warranty ................................................................................................................................... 21

Limitations ............................................................................................................................................. 21

Page 2 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

About Micro On/Off

LED

Sense #1

(yellow)

Sense #2

(purple)

Antenna

Second Load Terminal optional based on region

Features and Benefits

- Wires in behind existing wall switch or outlet or in a fixture box (requires neutral wire)

- Compatible with latching, single momentary and dual momentary switches

- Sense wires allow local control from any standard wall switch

- Can contain up to 400 controller/responder links

- X10 compatible

- All settings preserved in non-volatile memory, even through power failures

- Beeper for easy setup assistance; can also function as a chime module

- Local programming lockout available via software

- 2-year warranty

In the Box Tools Needed Optional Accessories

Micro On/Off

Quick Start Guide

Slotted screwdriver

Phillips screwdriver

Wire cutter/stripper

Voltage meter

Mini Remote

INSTEON Hub

Before Installation

CAUTIONS AND WARNINGS

Read and understand these instructions before installing and retain them for future reference.

This product is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada. Use indoors only.

This product is not designed or approved for use on power lines other than 100-240VAC,50Hz or 60Hz, single phase. Attempting to use this product on non-approved power lines may have hazardous consequences.

- Use only indoors or in outdoor rated box

- Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing this product into.

Installing this product with the power on will expose you to dangerous voltages.

- Connect using only copper or copper-clad wire

- This product may feel warm during operation. The amount of heat generated is within approved limits and poses no hazards. To minimize heat buildup, ensure the area surrounding this product is as clear of clutter as possible.

- Each INSTEON product is assigned a unique INSTEON I.D., which is printed on the product’s label.

- To reduce the risk of overheating and possible damage to other equipment, do not use this product to control loads in excess of the specified maximum(s) or, install in locations with electricity specifications which are outside of the product’s specifications. If this device supports dimming, please note that dimming an inductive load, such as a fan or transformer, could cause damage to the dimmer, the load bearing device, or both. If the manufacturer of the load device does not recommend dimming, use a non-dimming INSTEON on/off switch. USER ASSUMES ALL RISKS ASSOCIATED WITH

DIMMING AN INDUCTIVE LOAD.

Page 3 of 21 2442-222/2442-422/2442-522 - Rev: 9/24/2014 12:46 PM

Identifying the Electrical Wires in Your Home (North America only)

- Line: usually black (may also be called hot, live or power), carries 120VAC electricity into the wall box

- Neutral: usually white or white wire bundle, commonly daisy-chained from box to box

- Load: usually black, from a separate cable jacket

- Ground: bare copper wire or metal fixture (if grounded)

Identifying the Electrical Wires in Your Home (Europe/Australia/New Zealand)

- As wire colors vary from country to country, make sure you always check your electrical wires with a voltage meter to correctly identify line, load, neutral and ground wires

- If you have any questions, consult an electrician or your electricity supplier to learn more about your country’s wiring colors and labels

IMPORTANT!

If you have any difficulties or questions, consult an electrician. If you are not knowledgeable about, and comfortable with, electrical circuitry, you should have a qualified electrician install the product for you.

Identify Switch Type

Before you install Micro module behind a switch, you must determine which switch operation mode applies to your switch—latching, single momentary or dual momentary—as each is wired differently:

Latching (default mode): Switch has no central position. It can be tapped on both the top and bottom and remains in that state once released.

Single momentary: Switch can only be tapped in one location. It returns to central position once released.

Dual momentary: Switch can be tapped on both the top and bottom. It returns to central position once released.

Once you have identified your switch type, install Micro module according to the corresponding wiring diagram, then see “Switch Operation Mode” to program Micro module for your specific switch type.

Note: If you are installing Micro module behind a wall outlet or in a fixture, switch operation mode does not apply.

Page 4 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Installation

1) Write down the INSTEON ID found on the back of the unit (XX.XX.XX)

2) Turn off breaker/fuse and verify that the power is off

3) Disconnect wires from existing switch, fixture or outlet and prep all wires to be connected to Micro module, with 3/16” (5mm) of bare wire on the ends

4) Connect wires per diagram which corresponds to your installation

Note: sense lines carry very low current (~0.35mA 240V, ~0.17mA for 120V)

5) After ensuring wires are firmly connected and that there is no exposed wire, turn on breaker/fuse

After a few seconds, load will turn on (if wired into switch or fixture) and Micro module LED will turn green

6) Test by tapping Micro module on/off buttons

Load will turn on and off

Micro Module LED will turn green when load is on and red when load is off

7) If installing a single momentary or dual momentary switch a) Press and hold set button until it beeps

LED will start blinking green b) Press and hold set button until it beeps a second time

LED will start blinking red c) Press and hold set button until it beeps a third time

LED will start blinking green

Page 5 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

d) Perform the step that applies

For single momentary: slowly tap set button four times

LED will continue blinking green

For dual momentary: slowly tap set button five times

LED will start double-blinking green

To switch back to latching: slowly tap set button six times

LED will start blinking green e) Once the mode is selected, press and hold set button until it double-beeps

LED will stop blinking and turn green if load is on or red if load is off

Switch Operation Mode

By default, Micro module is programmed for a latching switch. Program the switch operation for single momentary mode, dual momentary mode or back to latching mode according to your switch type. These settings can also be configured remotely via software (sold separately).

To determine Micro module’s current switch operation mode, simply tap Set button:

• If it beeps, Micro module is configured for a single momentary switch

• If it double-beeps, Micro module is configured for a dual momentary switch

• If it triple-beeps, Micro module is configured for a latching switch (default)

Change to Single Momentary Mode

1) Press and hold Set button until it beeps

LED will start blinking green

2) Press and hold Set button until it beeps again

LED will start blinking red

3) Press and hold Set button until it beeps a third time

LED will start blinking green

4) Slowly tap Set button four times

LED will continue blinking green

5) Press and hold Set button until it double-beeps

LED will stop blinking

6) Test mode change by tapping switch on and off

Load will respond appropriately

Change to Dual Momentary Mode

1) Press and hold Set button until it beeps

LED will start blinking green

2) Press and hold Set button until it beeps again

LED will start blinking red

3) Press and hold Set button until it beeps a third time

LED will start blinking green

4) Slowly tap Set button five times

LED will start double-blinking green

5) Press and hold Set button until it double-beeps

LED will stop blinking

6) Test mode change by tapping switch top and bottom

Load will respond appropriately

Change to Latching Mode (default)

1) Press and hold Set button until it beeps

LED will start blinking green

2) Press and hold Set button until it beeps again

LED will start blinking red

Page 6 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

3) Press and hold Set button until it beeps a third time

LED will start blinking green

4) Slowly tap Set button six times

LED will continue blinking green

5) Press and hold Set button until it double-beeps

LED will stop blinking

6) Test mode change by tapping switch on and off

Load will respond appropriately

3-Way Toggle Mode (Latching Switches Only, Default)

Because Micro module comes programmed for latching switches, 3-way toggle mode is enabled by default.

Normally, a latching switch reads the switch’s up position as on and down position as off. For example, if you turn

Micro module on from the latching switch and off from another controller, the switch is still in the up (on) position; turning Micro module back on from the switch would require you to tap the switch down, then up again.

The 3-way toggle mode overrides this sense feature, so in that same scenario—turning Micro module on at the switch and off from another controller, so switch is in up (on) position—you could then turn Micro module on at the switch by tapping it down.

If you are installing Micro module behind a single or dual momentary switch, 3-way toggle mode is ignored. If desired, you can disable (or re-enable) 3-way toggle mode by following these instructions:

1) Press and hold Set button until it beeps

LED will start blinking green

2) Press and hold Set button until it beeps again

LED will start blinking red

3) Press and hold Set button until it beeps a third time

LED will start blinking green

4) Press and hold Set button until it beeps a fourth time

LED will start blinking red

5) Tap Set button

Micro module will beep and LED will start double-blinking red

6) Press and hold Set button until it double-beeps

LED will stop blinking

3-way toggle mode is now disabled (or re-enabled)

Local Control Operation

Micro module’s switch operation mode affects how it responds to commands from the switch. This is why it’s

important to program Micro module for the specific type of switch you are using. Micro module’s on/off buttons function exactly like the top and bottom of your wall switch.

Latching Wall Switch (Default)

Note that this table refers to the latching switch operation if 3-way toggle mode is disabled (it is enabled by default).

Connected load/responders

Latching switch Tap LED

On

Top

(ramped)

Green

Off

Bottom

(ramped)

Red

Page 7 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Single Momentary Switch

Single momentary switch

Switch

Dual Momentary Switch

Dual momentary switch

Top

Bottom

Connected load/responders

Tap Press and hold

On/Off

(ramped)

Brighten/Dim until release or full-on/off

(dimmable responders only)

Double-tap LED

On/Off

(instant)

Green/

Red

Connected load/responders

Tap Press and hold

On

(ramped)

Brighten until release or 100%

(dimmable responders only)

Off

(ramped)

Dim

until release or off

(dimmable responders only)

Double-tap LED

On

(instant)

Green

Off

(instant)

Red

Adjust Local Settings

Change LED Brightness (or turn it off)

Default = 50% brightness level

1) Press and hold Set button until it beeps

LED will start blinking green

2) Press and hold Set button until it beeps again

LED will start blinking red

3) Press and hold Set button until it beeps a third time

LED will start blinking green

4) Tap Set button once

LED will start double-blinking green

5) Press and hold Set button until it beeps

LED will turn green (at brightness of connected load)

6) Press and hold Micro module on/off buttons to brighten or dim LED to desired brightness

7) Tap Set button

Micro On/Off will double-beep and return to ready mode

Error Blink

Default = enabled

This setting is only adjustable via software or a central controller. Micro module LED will blink red once if one or more responders do not acknowledge a message and will blink green once if all responders are successful.

Page 8 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Blink on Traffic

Default = disabled

This setting is only adjustable via software or a central controller. Micro module LED will blink red if it detects noise that could disrupt communication.

Beep on Button Press

Default = disabled

This setting is only adjustable via software or a central controller. Micro module will beep every time its connected switch is tapped or a button is pressed.

Programming Lock

Default = disabled

This setting is only adjustable via software or a central controller. When enabled, Programming Lock will disable the

Set button so that a user can not adjust settings or modify links. This is typically used in commercial or installer applications.

INSTEON Setup

Some products have subtle differences in their setup procedures. Please refer to the other devices’ owner’s manuals for details.

INSTEON Controllers, Responders and Links

• The INSTEON “transmitter” is called a controller

• The INSTEON “receiver” is called a responder

• The association between the controller and responder is called a link

Link

Controller Responder

Note that a link is one way. If you wish to have control “the other way,” simply add a link “the other way.”

Configure INSTEON Settings

Most Micro module links and settings can be configured locally—during installation with the module’s Set button or after installation using the switch connected to the module.

All Micro module settings can be managed remotely via software (sold separately).

Make Micro Module a Responder (Set button)

Note: you must perform these steps before reinstalling the wall switch, outlet or fixture.

1) Press and hold controller Set button until it beeps

Page 9 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Controller LED will start blinking

You will have four minutes to complete the next steps before linking mode times out

2) Adjust load connected to Micro module to desired brightness level (even off)

3) Press and hold Micro module Set button until it double-beeps

Controller will double-beep and its LED will stop blinking

4) Test link by tapping controller button on and off

Load connected to Micro module will respond appropriately

Make Micro Module a Responder (Switch)

1) Press and hold controller Set button until it beeps

Controller LED will start blinking

You will have four minutes to complete the next steps before linking mode times out

2) Adjust load connected to Micro module to desired level (on or off)

3) Quickly tap switch connected to Micro module exactly five times in less than four seconds. (If using a latching or dual momentary switch, alternate switch directions: up-down-up-down-up or down-up-down-up-down.) After tapping switch, wait two seconds.

Micro module will double-beep

Controller will double-beep and its LED will stop blinking

4) Test link by tapping controller button on and off

Load connected to Micro module will turn on and off

Make Micro Module a Controller (Set button)

Note: you must perform these steps before reinstalling the wall switch, outlet or fixture.

1) Press and hold Micro module Set button until it beeps

Micro module LED will start blinking green

You will have four minutes to complete the next steps before linking mode times out

1

2) Adjust responder to desired state

3) Press and hold responder Set button until it double-beeps

Micro module will double-beep and its LED will stop blinking

2

4) Test link by tapping or pressing and holding Micro module on/off buttons to turn on/off or brighten/dim

Responder will respond appropriately

Make Micro Module a Controller (Switch)

1) Quickly tap switch connected to Micro module exactly five times in less than four seconds. (If using a latching or dual momentary switch, alternate switch directions: up-down-up-down-up or down-up-down-up-down.) After tapping switch, wait two seconds.

Micro module will beep to indicate it has entered linking mode

You will have four minutes to complete the next steps before linking mode times out

2) Adjust responder to desired state

3

3) Press and hold responder Set button until it double-beeps

Micro module will double-beep and its LED will stop blinking

4) Test link by tapping switch connected to Micro module to turn on/off or brighten/dim

Responder will respond appropriately

3

2

1

If responder is a multi-scene device such as a KeypadLinc, tap scene button you wish to control until the LED is in the desired scene state (on or off).

If either controller or responder LED continues blinking, the addition failed. Tap device’s Set button until LED stops blinking and try linking again.

If responder is a multi-scene device such as a KeypadLinc, tap scene button you wish to control until the LED is in the desired scene state (on or off)

Page 10 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Groups

Devices in a group share all the same settings (e.g., on-level, ramp rate). This keeps all group members synchronized. Every device in a group is both a controller of, and responder to, all the other devices. The most common example of a group is a 3-way lighting circuit (2 switches). For simplicity, we will assume that the desired group level is on.

The following steps will create a virtual 3-way circuit including device “A” and device “B”:

1) Turn A and B on

2) Press and hold A Set button until it beeps

A status LED will start blinking green

3) Press and hold B Set button until it double-beeps

A will double-beep and its LED will stop blinking

4) Press and hold B Set button until it beeps

B LED will start blinking green

5) Press and hold A Set button until it double-beeps

B will double-beep and its LED will stop blinking

6) Test by turning load on and off from A and then B

The load(s) and both A and B LEDs will remain in synch

Scenes

Devices in a scene can each have different settings. This provides for advanced scene creation. Software is recommended for scene management.

Example of a scene with 1 controller and Micro module as a member:

1) Press and hold controller button until it beeps

Controller LED will start blinking green

2) Tap controller Set button

Controller LED will start double-blinking green

3) Adjust load to desired scene state (on or off)

4) Press and hold Micro module Set button until it double-beeps

5) For each additional scene member: a. Adjust member to desired scene state b. Press and hold Set button until it double-beeps

6) Tap controller Set button

Controller will beep and LED will stop blinking

7) Test by tapping controller button on and off

Micro module and other scene responders will all respond appropriately

Make Micro Module a Controller of Multiple Responders

1) Press and hold Micro module Set button until it beeps

LED will start blinking green

2) Tap Micro module Set button

LED will start double-blinking green

3) For each responder you are adding: a. Adjust responder to desired scene state b. Press and hold Set button until it double-beeps

4) Tap Micro module Set button

Micro module will beep and LED will stop blinking

5) Test by tapping switch wired into Micro module on and off

All the responders will turn on and off

Page 11 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Remove Micro Module as a Controller

If you no longer want Micro module to control another device (or are removing Micro module from your network) it is important that you follow the instructions below for each responder.

1) Press and hold Micro module Set button until it beeps

LED will start blinking green

2) Press and hold Micro module Set button until it beeps again

LED will start blinking red

3) Press and hold responder Set button until it double-beeps

Micro module will double-beep and LED will stop blinking

4) Test by tapping Micro module on and off

Former responder will not respond

Remove Micro Module as a Responder

If you no longer want a controller button to control Micro module, follow these directions.

Note: If you ever wish to uninstall Micro module, it is important that you remove all Micro module responder links.

Otherwise, controllers will repetitively retry commands, creating network delays.

1) Press and hold controller button until it beeps

LED will start blinking green

2) Press and hold controller button until it beeps again

LED will start blinking red

3) Press and hold Micro module Set button until it double-beeps

Controller LED will stop blinking

4) Test by tapping controller button on and off

Micro module will no longer respond

Remove Micro Module as a Controller of Multiple Responders

1) Press and hold Micro module Set button until it beeps

LED will start blinking green

2) Press and hold Micro module Set button until it beeps again

LED will start blinking red

3) Tap Micro module Set button

LED will start double-blinking red

4) For each responder you are removing: a. Press and hold Set button until it double-beeps

5) Tap Micro module Set button

Micro module will beep and LED will stop blinking

6) Test by tapping the switch wired into Micro module on and off

None of the former responders will respond

Factory Reset

All settings, links and scenes will be erased.

1) Press and hold Micro module Set button until it beeps

LED will start blinking green

2) Press and hold Micro module Set button until it beeps again

LED will start blinking red

3) Press and hold Micro module Set button until it beeps a third time

LED will start blinking green

4) Slowly tap Micro module Set button 3 times

LED will start double-blinking green

5) Press and hold Micro module Set button. Do not let go.

Micro module will begin to emit a long beep

Page 12 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

6) After beep stops, release Micro module Set button

After a few seconds, the LED will flash white

Micro module will double-beep and the load will turn on

X10 Setup

Micro module ships with no X10 address assigned.

Add X10 Address

1) Press and hold Set button until it beeps

LED will start blinking green

2) Send the X10 address 3 times (with or without commands)

Example: A1-AON-A1-AON-A1-AON or A1-A1-A1-AON

Micro module will double-beep and LED will stop blinking

3) Test by sending X10 on and off commands

Load will turn on and off

Remove X10 Address

1) Press and hold Set button until it beeps

LED will start blinking green

2) Press and hold Set button until it beeps again

LED will start blinking red

3) Send the X10 address 3 times (with or without commands)

Example: A1-AOFF-A1-AOFF-A1-AOFF or A1-A1-A1-AOFF

Micro module will double-beep and LED will stop blinking

4) Test by sending X10 on and off commands

Micro module will not respond

Page 13 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Specifications

General

Product name

Brand/manufacturer

Manufacturer product number

UPC

Micro On/Off

INSTEON

2443-222 (US)

2443-422 (EU)

2443-522 (AUS/NZ)

813922012736 (US)

813922012743 (EU)

813922012750 (AUS/NZ)

2 years, limited Warranty

INSTEON

INSTEON

Maximum links/scenes

Status LED

Beep on button press

LED brightness

Local control

Commands supported as controller

Commands Supported as responder

Software configurable

RF range

Phase detect beacon

INSTEON device category

INSTEON device subcategory

Page 14 of 21

Controller and responder

400

Green when load is on, red when load is off

Blinks red once when responder does not acknowledge/blinks green once if all responders acknowledge (can be disabled/re-enabled via software)

Blinks red or green during setup

Blinks to indicate traffic (must be enabled via software)

Beeps when button is pressed or connected switch is tapped (must be enabled via software)

Adjustable, from off to bright

Yes

On

Fast-on

Off

Fast-off

Begin brighten

End brighten

On

Fast-on

Begin dim

End dim

Off

Fast-off

Beep

Yes

Up to 50 meters (150 feet) open air*

*Range may vary due to local interference/building construction

Yes

0x02 Switched Lighting Control (All Frequencies)

2443-222 (915 MHz) 0x2F

2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

X10

X10 address

X10 transmitter

X10 receiver

X10 status response

X10 resume dim

X10 minimum transmit level

X10 minimum receive level

X10 messages repeated

Mechanical

Mounting

Wires

Max Cable Size

Min Cable Size

Screw Micro connections

Case Color

Set button

Plastic

Beeper

LED

Dimensions

Weight

Operating Environment

Operating Temperature Range

Operating Humidity Range

Storage temperature range

Electrical

Voltage

Frequency

Maximum load

Page 15 of 21

2443-422 (869 MHz)

2443-522 (921 MHz)

0x31

0x32

1 optional (comes unassigned)

Yes

Yes

Supported

Supported (by setting local on-level to zero)

3.2 Vpp into 5 Ohms

20mV into 5 Ohms

No

Behind switch or outlet, or above light fixture in a single-gang electrical box

Sense 1 (yellow wire), 0.205mm

2

Sense 2 (purple wire), 0.205mm

2

/ 24 AWG

/ 24 AWG

4mm

2

(2.72mm diameter) / 12 AWG

1.5mm

2

/ 15 AWG

Line

Load 1

Load 1, second terminal

Neutral

White

Yes

UV stabilized ABS+PC

Yes

1, RGB

46.6mm H x 46.6mm W x 17.5mm D (1.8” H x 1.8” W x 0.7” D)

71.5g (2.5 oz)

Indoors

32°F to 104°F (0°C to 40°C)

0-90% relative humidity

-4

o

to 158

o

F (-20

o

to 70

o

C)

100VAC to 240VAC

50/60Hz auto detected at power-up

15A – 240VAC (US)

16A – 240VAC (EUR)

10A – 240VAC (AUS/NZ)

2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Load type(s)

Hardwired remote control

Retains all settings without power

3600W/240VAC Resistive

700W/240VAC Inductive/Capacitive

2000W/240VAC Bulbs/Low Voltage Halogen

Resistive

Inductive/capacitive

Low voltage halogen

Yes, latching and momentary switches supported

Yes, saved in non-volatile EEPROM

Standby power consumption

Safety approved

Certifications

< 1 watt

ETL, CE, C-Tick

FCC 15.107, 15.109, 15.249

RSS 210

EN 300 220-2, 301 489-3

AS/NZS 4268, CISPR 22

UL 244A

IEC 60669-2-1

SBPMM01 FCC ID

All product specifications are subject to change.

Page 16 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Troubleshooting

Problem

The LEDs on Micro module are not turning on at all

The switch I'm replacing only has two wires

Micro module is not getting power

Possible Cause Solution

Make sure the circuit breaker is turned on

Check junction box wires to ensure all connections are tight and no bare wires are exposed

Check the light fixture to ensure all connections are tight and no bare wires are exposed

Micro module needs a neutral wire in order to operate

Look in the rear of the junction box for a group of wires tied together with a wire nut. Those are commonly neutral wires.

Pull a neutral from nearby junction box

Micro module is not receiving signals from

INSTEON or X10 controllers

The controller is plugged into a power strip

Powerline signals can’t travel through some power filters. Plug controller into wall outlet.

Plug other modules into a signal filter or move the modules or controller to another outlet

Other modules are attenuating the signal or causing noise on the line

Micro module and the controller are on opposite powerline phases

INSTEON devices act as network repeaters.

Add new or move existing INSTEON devices and retest.

Make sure there are at least 2 dual-band

INSTEON products are properly installed to bridge the phases

The light turned on by itself

Another controller, a timer, or stray X10 signals triggered

Micro module

Install a power line signal blocker in your home to keep X10 signals from neighboring homes from interfering. Consider not using Micro module in X10 mode.

Micro module may have an undesired responder membership

Use software to remove membership or perform a factory reset and re-setup Micro module

Micro module responds to on commands but not off commands load connected to Micro module is producing electrical

Install an inline signal filter between the load and Micro module noise that is interfering with the Micro module reception of powerline signal

Install additional INSTEON devices to boost the INSTEON signal

When I try to turn on my light with another controller, the light will turn on, then back off

Micro module may be set up with an INSTEON on-level at a high brightness and an X10 address on-level at a low brightness

Remove the X10 address from Micro module

Remove the X10 address from INSTEON controller

When I press a button on

Micro module, it takes a long time for other

INSTEON devices it is controlling to respond

Micro module is trying to control a responder that is not responding and may have been removed

Connect power to the responder

If the INSTEON device is still available, remove it from Micro module and then re-add it

Perform a factory reset

Micro module doesn't Micro module ships without Add an X10 address

Page 17 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

respond to X10 address

A1 upon install an X10 Address

Micro module is locked up

A surge or excessive noise on the power line occurred

Micro module blinks green one time after it is

Micro module supports an error blink feature. A green blink indicates that all activated responders are communicating properly

Micro module blinks red one time after it is activated

Micro module supports an error blink to let you know that a responder did not acknowledge the command and that there is a lot of unacknowledged communications on the network

Micro module can turn off my responder, but nothing happens when I send an on

Responder’s scene level is off

Power cycle Micro module

Perform a factory reset

You may disable error blink via software if desired

Confirm that the responder is powered and available. If you don’t want this device to be a responder you can unlink it if available or use software to remove the link. Once the issue is resolved, you may disable error blink via software if desired.

Add responder to scene again at desired scene on-level

Controller can turn Micro module off, but not on

Micro module may be added to a scene at its off state

Add Micro module to scene again at desired scene on-level

Micro module still controls devices even after factory reset

The responder’s link was not removed prior to Micro module factory reset (called a half-link)

Remove responder from Micro module

Stuck/Disabled Button

If Micro module’s buttons are not responding, they may have been disabled due to a stuck button. If any button is pressed during power-up, or after power-up any Micro module button is pressed for about four minutes, Micro module engages stuck button mode and automatically disables all button actions. All buttons will remain disabled until next power cycle.

To re-enable buttons, ensure buttons are not being pressed, turn off breaker supplying power to Micro module and turn it back on. Micro module buttons should function again. Additionally, check Micro module’s installation location for any obstacles that could be pressing the buttons on Micro module’s face and causing stuck button mode.

Page 18 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Phase Bridge Detect Beacon/RF Range Test

Micro module automatically bridges the electrical phases in your home (via communications with other dual-band devices on the “other phase”). This is only important in 2-phase homes with powerline-only INSTEON products or buildings with both 2- and 3- phase circuits. The phase bridge detect beacon can also be used as an RF range test to see if your devices are within communication range. You will need at least one other INSTEON dual-band device installed.

1) Press and hold Set button until it beeps

LED will start blinking green

2) Press and hold Set button until it beeps again

LED will start blinking red

3) Press and hold Set button until it beeps a third time

LED will start blinking green

4) Slowly tap Set button twice

LED will continue blinking green

5) Press and hold Set button until it beeps

Micro module will start beeping once per second

LED will turn solid green

6) Check the LED behavior of other dual-band devices

Phase Bridge Detect Beacon

• If the other dual-band device is blinking green, it is on the other phase:

Device provides a phase bridge to Micro module

If the other dual-band device is blinking red, it is on the same phase:

Device does not provide a phase bridge to Micro module

Relocate if necessary (and practical)

If the other dual-band device is not blinking:

Device is not within RF range of Micro module so it does not provide a phase bridge

Relocate if necessary (and practical) or add an additional dual-band device

RF Range Test

• If LED is blinking:

Device is within RF communication range

• If LED is not blinking:

Device is not within RF communication range

Relocate if necessary (and practical) or add an additional dual-band device

7) Tap Set button

Micro module will stop beeping

Other device LEDs will stop blinking

If you have tried these solutions, reviewed the owner's manual, and still cannot resolve the issue you are having visit http://www.insteon.com/support or call INSTEON Support Line at 866-243-8022.

Page 19 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Certification and Warranty

Certification

This product has been thoroughly tested by ITS ETL SEMKO, a nationally recognized independent third-party testing laboratory. The North American ETL Listed mark signifies that the device has been tested to and has met the requirements of a widely recognized consensus of U.S. and Canadian device safety standards, that the manufacturing site has been audited, and that the manufacturer has agreed to a program of quarterly factory follow-up inspections to verify continued conformance.

FCC and Industry Canada Compliance Statement

The digital circuitry of this device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15B of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: • Re-orient or relocate the receiving antenna of the device experiencing the interference • Increase the distance between this device and the receiver • Connect the device to an AC outlet on a circuit different from the one that supplies power to the receiver • Consult the dealer or an experienced radio/TV technician.

WARNING: Changes or modifications to this device not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Cet appareil a été testé et s’avère conforme aux restrictions relatives aux équipements numériques de classe B, d’après l’article 15 des règlements du Conseil supérieur de l’audiovisuel américain (FCC). Ces restrictions ont été instaurées pour offrir une protection raisonnable contre les interférences nuisibles au sein d’une installation résidentielle. Cet appareil génère, utilise et peut émettre des fréquences radio et s’il n’est pas installé selon les instructions, peut nuire aux radiocommunications. Toutefois, rien ne garantit que des parasites ne surviendront pas dans une installation particulière. Si cet appareil cause des interférences nuisibles à la réception du téléviseur ou de la radio, ce que vous pouvez déterminer en ouvrant et en fermant votre appareil, nous vous invitons à essayer l’une des mesures correctives suivantes : • Réorientez l’antenne de réception installée sur l’appareil qui manifeste les parasites.

• Éloignez l’appareil du composant qui reçoit les ondes. • Branchez l’appareil dans une prise de courant CA différente de celle du composant qui reçoit les ondes. • Au besoin, consultez votre marchand électronique ou un technicien spécialisé dans le service des radios/téléviseurs pour des suggestions supplémentaires.

Declaration of Conformity

Hereby, INSTEON declares that this device is in compliance with the essential requirements and other relevant provisions of the following Directives:

1) Low Voltage Equipment Directive 2006/95/EC

2) Electromagnetic Compatibility Directive 2004/108/EC

3) Hazardous Substance Directive 2005/95/EC

Technical data and copies of the original Declaration of Conformity are available and can be obtained from INSTEON; 16542 Millikan Ave, Irvine, CA, USA.

User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE)

This document contains important information for users with regards to the proper disposal and recycling of INSTEON products. Consumers are required to comply with this notice for all electronic products bearing the following symbol:

Environmental Information for Customers in the European Union

European Directive 2002/96/EC requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams.

It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities.

Correct disposal and recycling will help prevent potential negative consequences to the environment and human health.

For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.

DECLARATION OF CONFORMITY TO R&TTE DIRECTIVE 1999/5/EC for the European Community, Switzerland, Norway, Iceland and Liechtenstein

Product category: general consumer (category 3).

English: This equipment is in compliance with the essential requirements and other relevant provisions of the European R&TTE Directive 1999/5/EC

Deutsch [German]: Dieses Gerät entspricht den grundlegenden Anforderungen und den weiteren entsprechenden Vorgaben der Richtlinie 1999/5/EU.

Nederlands [Dutch]: Dit apparaat voldoet aan de essentiele eisen en andere van toepassing zijnde bepalingen van de Richtlijn 1999/5/EC.

Svenska [Swedish]: Denna utrustning står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv

1999/5/EG.

Français [French]: Cet appareil est conforme aux exigences essentielles et aux autres dispositions pertinentes de la Directive 1999/5/EC

Español [Spanish]: Este equipo cumple con los requisitos esenciales asi como con otras disposiciones de la Directiva 1999/5/CE.

Português [Portuguese]: Este equipamento está em conformidade com os requisitos essenciais e outras provisões relevantes da Directiva 1999/5/EC.

Italiano [Italian]: Questo apparato é conforme ai requisiti essenziali ed agli altri principi sanciti dalla Direttiva 1999/5/CE.

Norsk [Norwegian]: Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser i EU-direktiv 1999/5/EF.

Suomi [Finnish]:Tämä laite tÿttää direktiivin 1999/5/EY olennaiset vaatimukset ja on siinä asetettujen muiden laitetta koskevien määräysten mukainen.

Dansk [Danish]: Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Direktiv 1999/5/EF.

Polski [Polish]: Urządzenie jest zgodne z ogólnymi wymaganiami oraz szczególnymi warunkami okreslonymi Dyrektywą UE: 1999/5/EC

ETL/UL Warning (Safety Warning)

CAUTION: To reduce the risk of overheating and possible damage to other equipment, do not install this device to control a receptacle, a motor-operated appliance, a fluorescent lighting fixture, or a transformer-supplied appliance.

Gradateurs commandant une DIN Raile a filament de tungstene – afin de reduire le risqué de surchauffe et la possibilite d’endommagement a d’autres materiels, ne pas installer pour commander une prise, un appareil a moteur, une DIN Raile fluorescente ou un appareil alimente par un transformateur.

Page 20 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

Limited Warranty

Seller warrants to the original consumer purchaser of this product that, for a period of two years from the date of purchase, this product will be free from defects in material and workmanship and will perform in substantial conformity to the description of the product in this Owner’s Manual. This warranty shall not apply to defects or errors caused by misuse or neglect. If the product is found to be defective in material or workmanship, or if the product does not perform as warranted above during the warranty period, Seller will either repair it, replace it, or refund the purchase price, at its option, upon receipt of the product at the address below, postage prepaid, with proof of the date of purchase and an explanation of the defect or error. The repair, replacement, or refund that is provided for above shall be the full extent of Seller’s liability with respect to this product. For repair or replacement during the warranty period, call INSTEON at 866-243-8022 with the Model # and Revision # of the device to receive an RMA# and send the product, along with all other required materials to:

INSTEON

ATTN: Receiving

16542 Millikan Ave.

Irvine, CA 92606-5027

Limitations

The above warranty is in lieu of and Seller disclaims all other warranties, whether oral or written, express or implied, including any warranty or merchantability or fitness for a particular purpose. Any implied warranty, including any warranty of merchantability or fitness for a particular purpose, which may not be disclaimed or supplanted as provided above shall be limited to the two-year of the express warranty above. No other representation or claim of any nature by any person shall be binding upon

Seller or modify the terms of the above warranty and disclaimer.

Home automation devices have the risk of failure to operate, incorrect operation, or electrical or mechanical tampering. For optimal use, manually verify the device state. Any home automation device should be viewed as a convenience, but not as a sole method for controlling your home.

In no event shall Seller be liable for special, incidental, consequential, or other damages resulting from possession or use of this device, including without limitation damage to property and, to the extent permitted by law, personal injury, even if Seller knew or should have known of the possibility of such damages. Some states do not allow limitations on how long an implied warranty lasts and/or the exclusion or limitation of damages, in which case the above limitations and/or exclusions may not apply to you. You may also have other legal rights that may vary from state to state.

Protected under U.S. and foreign patents (see www.insteon.com/patents)

© Copyright 2013 INSTEON, 16542 Millikan Ave., Irvine, CA 92606, 866-243-8022, www.insteon.com

Page 21 of 21 2443-222/2443-422/2443-522 - Rev: 9/24/2014 12:46 PM

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents