HP Support Link, Support Link II, HP37212B, Hayes Smartmodem 1200 Modems Manual
PDF
Dokument
Annonce
Annonce
oC]
Worldwide Response Center
HP 3000 APPLICATION NOTE #63
Configuring Telesupport Modems
For
MPE V/E Systems
1 Ea HEWLETT Е January 15, 1990
PACKARD | a Document P/N #5959-7834
HP Computer Museum
www.hpmuseum.net
For research and education purposes only.
RESPONSE CENTER APPLICATION NOTES
HP 3000 APPLICATION NOTES are published by the Worldwide Response Center and are
distributed with the Software Status Bulletin. These notes address topics where the volume of calls
received at the Center indicates a need for addition to or consolidation of information available through
HP support services. | |
Following this publication you will find a list of previously published notes and a Reader Comment
Sheet. You may use the Reader Comment Sheet to comment on the note, suggest improvements or
future topics, or to order back issues. We encourage you to return this form; we'd like to hear from you.
До н CEE =
NOTICE
The information contained in this document is subject to change without notice.
HEWLETT- PACKARD MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THIS
MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Hewlett-Packard shall not
be liable for errors contained herein or for incidental or consequential damages in connection with the
furnishing. performance or use of this material.
This document contains proprietary information which is protected copyright. All rights are reserved,
Permission to copy all or part of this document is granted provided that the copies are not made or
distributed for direct commercial advantage; that this copyright notice, and the title of the publication
and its date appear; and that notice is given that copying is by permission of Hewlett-Packard
Company. To copy otherwise, or to 0 republish, requires prior written consent of Hewlett -Packard
Company.
Copyright O 1990 by HEWLETT-PACKARD COMPANY
Configuring Telesupport Modems
For MPE V/E Systems
Introduction
This Application Note discusses the recommended configuration for the supported modems on ATP and
ADCC ports. Included is information on the I/O configuration of the port and how to configure each of
the supported modems:
e SUPPORT LINK
e SUPPORT LINK II
e HP37212B
e HAYES SMARTMODEM 1200
The HP37212A, RACAL VADIC VA3450 and VA3451 are also supported in some cases, but are not
discussed in this. Application Note. Also, not addressed in this Application Note is the HP50759A, which
is the newest telesupport modem from Hewlett-Packard. Contact the Response Center for more details
about any of these modems. |
Diagrams of the four modems are included for your reference:
SUPPORT LINK
| 52 О В = e - $ 2 3 4 3
TXD RXD WS CIS DSR OTR Mi MO | [muse | [even ) fornon)f on |f as ‘a "th
» |
fmf] 17] ccicats Support Link В
£n0
EST
À
STATUS
LED
LCD KEYPAD
INDICATORS
Support Link Front Panel
SUPPORT LINK II
HP37217B
AT EAN ARR a TT
-
©
НЕМ JN BH
27 EEE CEE
3727R8 24302 Бо:
© РОМ PLA TECOS. МОС М
HP 37212B Front Panel
A
[FES ge
A
LLE DE
LEEN
УЛОВ
AnS
E
e 13 ea :
Ы Г
alk
HAYES SMARTMODEM 1200
LED The front panel of the Smartmodern 1200 contains eight indicator
INDICATOR lights that permit a visual check of the modem's status
LIGHTS o a
SMARTMODEM 1200 BI -
(f) Hayes
From right to left, the indicator lights are:
MR = Modem Ready
TR = Terminal Ready
SD = SendData
RD = Receive Data
OH = Off Hook
CD = Carrier Detect |
АА ~ Auto-Answer Mode O
HS = High Speed (1200 bps)
CONFIGURING THE SYSTEM
The system should be configured as follows:
{If you have a Series 64, 68, or 70, refer to the section of this Application Note entitled CONFIGURING
THE SERIES 64, 68 OR 70. )
LOGDRT C T SUB TERMINAL REC OUTPUT MODE DRIVER DEVICE
DEV $ H Y TYPE TYPE SPEED WIDTH DEV NAME CLASSES
£f A P Е
N° E
“ATP: XXX ZZZ 0 16 1 10 120 40 XXX JAID HIOTERM1 YYYYYY
В "ADCC: ХХХ 222 0 16 1 10 120 40 XXX JAID HIOTERM2 YYYYYY
“where: XXX is the logical device number
YYYYYY is any device class name, such as MODEM
ZZZ is the Device Reference Table number
This configuration should also be used even if HPTrend c or Predictive Support are not installed on the
system.
CONFIGURING THE MODEM
'AUTODIAL CONFIGURATION:
(TYPE 2 CONFIGURATION for HPTrend or Predictive Support)
‘To configure your modem to enable HPTrend or Predictive Support to dial out automatically, use the
following procedure. If HPTrend or Predictive Support is not installed, refer to the MANUAL DIAL
CONFIGURATION section of this Application Note.
SUPPORT LINK
1. Put the modem in an IDLE state by pressing the RESET button on the
front panel. The LCD (liquid crystal display) should display IDLE.
2. Press OPTION. The LCD will display OPTION.
3. Press 1, then press ENTER. The LCD will display 1*n (where n is the
Е | current setting of Option 1).
4. Press 3, then press ENTER. The LCD will display OPTION again. This
action will set Option 1 to a setting of
3, standard settings.
5, Press RESET. ~~ The LCD will display IDLE.
7. Press 1, then press ENTER. The LCD will display 1#n.
8. Press 2, then press ENTER. The LCD will display OPTION. Option 1 is
- now set to a 2 to allow nonstandard
settings. |
9. Press 8, then press ENTER. | The LCD will display 8*n.
10. Press 2, then press ENTER. | The LCD will display OPTION. Option 8 is
o now set to a 2 to put DTR under port
control.
11. Press 15, then press ENTER. — The LCD will display 15*n. .
12. Press 3, then press ENTER. — The LCD will display OPTION. Option 15 is
oo now set to a 3 to force DSR on. 3
13. Press 24, then press ENTER. ‚The LCD will display 24*n.
14. Press 2, then press ENTER. —— The LCD will display OPTION. Option 24 is
now set to a 2 to monitor CD.
15. If your telephone system only
uses PULSE (ROTARY) dialing:
Press 22, then press ENTER. The LCD will display 22*n.
Press 1, then press ENTER. The LCD will display OPTION. Option 22
| is now set to a 1 for Pulse dial.
16. If your telephone system uses O
TONE (Touchtone) dialing:
Press 22, then press ENTER. The LCD will display 22*n.
Press 2, then press ENTER. The LCD will display OPTION. Option 22
is now set to a 2 for Tone dial.
17. Press Reset. | The LCD will display IDLE.
SUPPORT LINK Il
1. Attach the modem to an HP terminal with a straight through RS-232 cable
such as the 13242N or the 40242M cable.
2. Set the terminal to 1200 BAUD.
3. Press the VOICE/DISC button to put the modem in IDLE mode. The LEDs
that should be on are DTR, HS and TST.
4. On the terminal, hold down CONTROL and type E.
5. Press RETURN. The terminal will display:
HELLO I AM READY - 0
. |
10.
11.
12.
13.
14.
15.
- 16.
Type O (the letter 0) and press RETURN. The terminal will display:
“OPTION NUMBER (CR=QUIT, M=MENU)--> | |
Type 1 and press RETURN. The terminal displays:
1. STD OPTIONS (Y=1, N=2) 3
Type 2 and press RETURN. This sets Option 1 to a 2 (allows nonstandard
settings). The terminal displays:
#OPTION NUMBER (CR=QUIT, M=MENU)-->
Type 8 and press RETURN. The terminal displays:
8. DTR FORCE ON (Y=1,N=2)
Type 2 and press RETURN. The terminal displays:
#OPTION NUMBER (CR=QUIT,M=MENU)-->
This sets Option 8 to a 2 to put DTR under port control.
Type 15 and press RETURN. The terminal displays:
15. DSR CONTROL OPT (1-3)
Type 3 and press RETURN. The terminal displays:
«OPTION NUMBER (CR=QUIT, M=MENU)-->
This sets Option 15 to a 3 to force DSR on.
If your telephone system only uses Pulse (Rotary) dialing:
Type 22 and press RETURN. The terminal displays:
22. TONE/PULSE OPT (1-3)
Type 3 and press RETURN. The terminal displays:
*OPTION NUMBER (CR=QUIT, M=MENU)-->
If your telephone system uses Tone (Touchtone) dialing:
Type 22 and press RETURN. The terminal displays:
22. TONE/PULSE OPT (1-3)
Type 2 and press RETURN. The terminal displays:
“OPTION NUMBER (CR=QUIT, M=MENU)-->
Press RETURN to exit the configuration menu.
Type I and press RETURN to put the modem in idle mode.
HP37212B
The HP37212B is supported for autodial with Predictive Support version À. 02.03 or greater. For version
A.01.00, the modem is supported if you have PMNXFRDP. HP05093A and PUTXFRDM. HPOSO93A
with versions of A.02.A2. Your Customer Engineer can provide these versions. |
The HP37212B is not supported for HPTrend unless you have installed patch BV 10 which is available
from the Response Center. |
1. The DIP switches on the rear of the modem must be set as follows:
Switch 3 is closed (Closed is up or 1). HP computer mode.
Switch 12 is closed. | DTR behaves to RS-232 definition.
All other switches are open. (open is DOWN or 0).
2. Push in the Auto Answer button on the front panel.
3. Push in the SPEED button on the front to select 2400 BAUD if you desire.
4. The LOOPBACK button should not be pushed in.
5. When the modem is powered up and connected to the port, the following
LEDs should be lit:
ON
DTR
2400 (if the SPEED button has been toggled)
HAYES SMARTMODEM 1200
The Hayes 1200 Smartmodem 1s supported for autodial with Predictive Support, version A.02.03 or
greater. It is nof supported with HPTrend.
1. Power off the modem and unplug it.
2. Pull off the front cover of the modem with a screwdriver.
3. Set the DIP switches as follows:
SWITCH SETTING PURPOSE
1 up DTR lead is supported
2 up Result Code is in words
3 up No result codes are sent
4 up Commands are echoed
5 up Auto Answer is on
6 down CD is forced on
7 up Single Line
8 down Command Recognition is Enabled
9 up BELL standard protocol
10 down Reset when DTR makes an ON to OFF transition
4. Plug the modem in and power it up.
5. When the modem is plugged into the port, the following LEDs should be on:
HS
AA
TR
MR
F
MANUAL DIAL CONFIGURATION:
(TYPE 1 CONFIGURATION for HPTrend or Predictive Support)
To configure the modems for manual dial for HPTrend or Predictive Support, use the following procedure.
This configuration should also be used even if HPTrend or Predictive Support are not installed on the
system.
SUPPORT LINK
1.
10.
11.
12.
13.
14,
15.
Put the modem in an IDLE state by pressing the RESET button on the
front panel.
Press OPTION.
Press 1, then press ENTER.
Press 3, then press ENTER.
Press RESET.
Press OPTION.
Press 1, then press ENTER.
Press 2, then press ENTER.
Press 8, then press ENTER.
Press 2, then press ENTER.
Press 15, then press ENTER.
Press 2, then press ENTER.
Press 24, then press ENTER.
Press 2, then press ENTER.
If your telephone system only
uses Pulse (Rotary) dialing:
Press 22, then press ENTER.
The LCD will display
The LCD will display
The LCD (liquid crystal display) should display IDLE.
OPTION.
1 » n (where n is
the current setting of Option 1).
The LCD will display
OPTION again. This
action will set Option 1 to a setting of
3, standard settings.
The LCD will display
The LCD will display
The LCD will display
‘The LCD will display
is now set to a 2 to
settings.
The LCD will display
The LCD will display
is now set to a 2 to
control.
The LCD will display
The LCD will display
is now set to a 2 to
mode.
The LCD will display
The LCD will display
is now set to a 2 to
The LCD will display
IDLE.
OPTION.
1*n.
OPTION. Option 1
allow nonstandard
8*n.
OPTION. Option 8
put DTR under port
15*n.
OPTION. Option 15
set DSR off in test
24%n
OPTION. Option 24
monitor CD.
22*n.
. У .
oA 1
16.
17.
Press 1, then press ENTER. - The LCD will display OPTION. Option 22
| | is now set to a 1 for Pulse dial.
If your telephone system uses
Tone (Touchtone) dialing:
Press 22, then press ENTER. - The LCD will display 22#n.
Press 2, then press ENTER. The LCD will display OPTION. Option 22
; is now set to a 2 for Tone dial.
Press RESET. a The LCD will display IDLE.
SUPPORT LINK II
10.
11.
12.
Attach the modem to an HP terminal with a straight through RS-232 cable
such as the 13242N or the 40242M cable. |
Set the terminal to 1200 BAUD.
Press the VOICE/DISC button to put the modem in IDLE mode. The LEDs
that should be on are DTR, HS, and TST.
On the Terminal, hold down CONTROL and type E.
Press RETURN. The terminal will display:
HELLO I AM READY -
Type O (the letter 0) and press RETURN. The terminal will display:
*OPTION NUMBER (CR=QUIT, M=MENU)--> | |
Type 1 and press RETURN. The terminal displays:
1. STD OPTIONS (Y=1, N=2)
Type 2 and press RETURN. This sets Option 1 to a 2 (allows nonstandard
settings). The terminal displays:
*OPTION NUMBER (CR=QUIT, M=MENU)-->
Type 8 and press RETURN. The terminal displays:
8. DTR FORCE ON (Y=1, N=2) |
Type 2 and press RETURN. The terminal displays:
*OPTION NUMBER (CR=QUIT, M=MENU)-->
Option 8 is now set to a 2 to put DTR under port control.
Type 15 and press RETURN. The terminal displays:
15. DSR CONTROL OPT (1-3)
Type 2 and press RETURN. The terminal displays:
“OPTION NUMBER (CR=QUIT, M=MENU)-->
Option 15 is now set to a 2 to set DSR off in test mode.
10
13. If your telephone system only uses Pulse (Rotary) dialing:
Type 22 and press RETURN. The terminal displays:
22. TONE/PULSE OPT (1-3)
Type 3 and press RETURN. The terminal displays:
"OPTION NUMBER (CR=QUIT, M=MENU)-->
14. If your telephone system uses Tone (Touchtone) dialing:
Type 22 and press RETURN. The terminal displays:
22. TONE/PULSE OPT (1-3) |
Type 2 and press RETURN. The terminal displays:
#OPTION NUMBER (CR=QUIT, M=MENU)-->
15. Press RETURN to exit the configuration menu.
16. ‘Type I and press RETURN to put the modem in IDLE mode.
HP37212B
1. The DIP switches on the rear of the modem must be set as follows:
Switch 3 is closed (Closed means UP or 1). (HP computer mode)
Switch 11 is closed. | (DSR/CTS/CD behaves to RS-232 definition
Switch 12 is closed. (DTR behaves to RS-232 definition)
All other switches are open (Open means DOWN or 0).
2. Push in the Auto Answer button on the front panel.
3. Push in the SPEED button on the front to select 2400 BAUD if you desire.
HPTrend can only use 1200 BAUD.
4. The LOOPBACK button should not be pushed in.
5. When the modem is powered up and connected to the port, the following
LEDs should be lit:
‚ON
DTR
2400 (if the SPEED button has been toggled)
6. For Predictive Support, insert the following line in the JCL for
PredictA, PredictJ, Firstrun, and PMDCTEST if you desire to
manually dial the modem at 2400 BAUD:
!setjew BAUD, 2400
HAYES SMARTMODEM 1200
The Hayes Smartmodem 1200 cannot be manually dialed. Configure the modem for autodial for
_ e | Predictive Support.
11
CONFIGURING THE SERIES 64, 68 OR 70:
For an HP 3000 Series 64, 68 or 70 system, the modem may be connected to a standard modem port via a
jumper cable at the Remote Diagnostic Interface. The Remote Diagnostic Interface is in the upper right
corner of the rear of the machine. See the CABLES section for details.
If the Remote Diagnostic Interface is being used in this way, the modem and the system MAY need to be
configured differently. The following questions will determine if a different configuration should be
used:
1. Is the system a series 64, 68, or 70?
2. Is the modem jumpered through the Remote Diagnostic Interface?
3. Do you plan to use HPTrend or Predictive Support?
4. Do you prefer NOT to power off the modem prior to entering
the "RM" command to enable remote console? (This procedure is taken
when the Response Center must dial in and access the system console to
perform certain maintenance or diagnostic functions).
If the answer to ANY of these questions is NO, then use the configuration discussed under
CONFIGURING THE SYSTEM in this Application Note. If you do not plan to use HPTrend or Predictive
Support, configure the system and the modem as recommended in the MANUAL DIAL
CONFIGURATION section of this Application Note.
If the answer to ALL four questions is YES, then configure the system and modem as follows:
LOG DRT C T SUB TERMINAL REC OUTPUT MODE DRIVER DEVICE
DEV # H Y TYPE TYPE SPEED WIDTH DEV NAME CLASS
# A Р |
N E
ATP: XXX ZZZ 0 16 0 10 120 40 XXX JAID HIOTERM1 YYYYYY
ADCC: XXX 2ZZ 0 16 © 10 120 40 XXX JAID HIOTERM2 YYYYYY
where: XXX is the logical device number
YYYYYY is any device class name, such as MODEM
ZZZ is the Device Reference Table number
Note that the same security considerations apply to this configuration as
discussed in the SYSTEM SECURITY section of this note.
CONFIGURING THE MODEM FOR THE SERIES 64, 68 OR 70
(TYPE 3 CONFIGURATION for HPTrend or Predictive Support)
12
SUPPORT LINK
10.
11.
12.
13.
14.
15.
16.
17.
Put the modem in an IDLE state by pressing the RESET button on the
front panel. The LCD (liquid crystal display) should display IDLE.
Press OPTION.
. Press 1, then press ENTER.
Press 3, then press ENTER.
Press RESET.
Press OPTION.
Press 1, then press ENTER.
Press 2, then press ENTER.
Press 8, then press ENTER.
Press 1, then press ENTER.
Press 15, then press ENTER.
Press 2, then press ENTER.
Press 24, then press ENTER.
Press 2, then press ENTER.
If your telephone system only
uses Pulse (Rotary) dialing:
Press 22, then press ENTER.
Press 1, then press ENTER.
If your telephone system uses
Tone (Touchtone) dialing:
Press 22, then press ENTER.
Press 2, then press ENTER.
Press RESET.
The LCD will display OPTION.
The LCD will display 1 *n (where n is
the current setting of Option 1).
The LCD will display OPTION again. This
action will set Option 1 to a setting of
3, standard settings. |
The LCD will display IDLE.
The LCD will display OPTION.
The LCD will display 1*n.
The LCD will display OPTION. Option 1 is
now set to a 2 to allow nonstandard
settings.
The LCD will display gen.
The LCD display OPTION. Option 8 is now
set to a 1 to force DTR on.
The LCD will display 15*n.
The LCD will display OPTION. Option 15 is
now set to a 2 to set DSR off in test
mode.
The LCD will display 24#n.
The LCD will display OPTION. Option 24
is now set to a 2 to monitor CD.
The LCD will display 22*n.
The LCD will display OPTION. Option 22
is now set to a 1 for Pulse dial. |
The LCD will display 22#n.
The LCD will display OPTION. Option 22
is now set to a 2 for Tone dial.
The LCD will display IDLE.
13
SUPPORT LINK II
10.
11.
12.
13.
14.
15.
Attach the modem to an HP terminal with a straight through RS-232 cable
such as the 13242N or the 40242M cable.
Set the terminal to 1200 BAUD.
Press the VOICE/DISC button to put the modem in IDLE mode. The LEDs
that should be on are DTR, HS and TST. |
On the terminal, hold down CONTROL and type Е.
Press RETURN. The terminal will display:
HELLO I AM READY
*
Type O (the letter 0) and press RETURN. The terminal will display:
*O OPTION NUMBER (CR=QUIT, M=MENU)-->
Type 1 and press RETURN. The terminal displays:
STD OPTIONS (Y=1, N=2)
Type 2 and press RETURN. This sets Option 1 to a 2 (allows nonstandard
settings). The terminal displays:
OPTION NUMBER (CR=QUIT, M=MENU)-->
Type 8 and press RETURN. The terminal displays:
8. DTR FORCE ON (Y=1, N=2)
Type 1 and press RETURN. The terminal displays:
*OPTION NUMBER (CR=QUIT, M=MENU)-->
This sets Option 8 to a 1 to force DTR on.
Type 15 and press RETURN. The terminal displays:
15. DSR CONTROL OPT (1-3)
Type 2 and press RETURN. The terminal displays:
“OPTION NUMBER (CR=QUIT, M=MENU)--> |
This sets Option 15 to a 2 set DSR off in test mode.
If your telephone system only uses Pulse (Rotary) dialing:
Type 22 and press RETURN. The terminal displays:
22. TONE/PULSE OPT (1-3)
Type 3 and press RETURN. The terminal displays:
*OPTION NUMBER (CR=QUIT, M=MENU)-->
If your telephone system uses Tone (Touchtone) dialing:
Type 22 and press RETURN. The terminal displays:
22. TONE/PULSE OPT (1-3)
Type 2 and press RETURN. The terminal displays;
*OPTION NUMBER (CR=QUIT, M=MENU)-->
Press RETURN to exit the configuration menu.
14
16. Type I and press RETURN to put the modem in IDLE mode.
HP37212B
The HP37212B is supported for autodial for Predictive Support version A.02.03 or greater. Version
A.01.00 is supported with the modem if PMNXFRDP.HP05093A and PUTXFRDM. HP05093A is
A.02.A2. Your Customer Engineer can provide these versions.
The HP37212B is not supported for autodial for HPTrend without the BV10 patch. This patch is
available from the Response Center.
1. The DIP switches on the rear of the modem must be set as follows:
Switch 3 is closed (Closed means UP or 1). (HP computer mode.)
Switch 11 is closed. | (DSR/CTS/CD behaves to RS- -232
definition, DTR is forced on).
All other switches are open. (Open means DOWN or 0).
2. Push in the AUTO ANSWER button on the front panel.
3. Push in the SPEED button on the front panel to select 2400 BAUD if you
desire.
4. The LOOPBACK button should not be pushed in.
5. When the modem is powered up and connected to the port, the following
LEDs should be lit:
ON
DTR
2400 (if the SPEED button has been toggled)
HAYES SMARTMODEM 1200
The Hayes Smartmodem is supported for autodial with Predictive Support, version A.02.03 or greater. It
is not supported with HPTrend.
1. Power off the modem and unplug it.
2. Pull off the front cover of the modem with a screwdriver.
3. Set the DIP switches as follows: |
SWITCH SETTING PURPOSE
1 down DTR is forced on
2 up Result Code is in words
3 up No result codes are sent
4 up Commands are echoed
5 up . Auto Answer is on
15
6 up CD is not forced on
7 up Single line
8 down Command recognition is Enabled
9 up - BELL standard protocol
10
down Reset when DTR makes ON to OFF transition.
4. Plug the modem in and power it up.
5. When the modem is plugged into the port, the following LEDs should be on:
HS В
АА
TR
MR
SYSTEM SECURITY
If you configure the modems for Autodial, this will affect the system’s security. If the phone connection
is broken before "BYE" is typed, the session may remain active and the next person who dials in could be
connected to the same session. To maintain system security you could:
e Disconnect or turn off the modem before and after a session.
e Use the REFUSE and ACCEPT commands to control access to the modem port. Enter the
REFUSE command at the end of each session and the ACCEPT command before the start of
à new session.
na. Las
HPTrend and Predictive Support are the only supported applications that can autodial a modem on the HP
3000. Other applications involving programmatic autodial are unsupported due to the security
considerations discussed above.
CABLES
Modem to System Cable: :
All HP modems are shipped with a 30062B modem cable. This cable is a nonsymmetrical cable. One end
of the cable is labeled DATASET and must be connected to the modem. The other end of the cable is
labeled COMPUTER and must be connected to the computer system.
16
Point-to-Point Data Link
Phone Jack to Modem Cable:
The phone cable (RJ-11 cable) is connected to the phone jack on one end and to the modem on the other
end. Use this chart to determine where the phone cable should be connected on the modem.
MODEM MODEM PHONELINE CONNECTOR
Support Link | TELCO
Support Link II TELLINE
HP372128 US TELCO
HAYES 1200 TO LINE
An optional connector is available on each modem where a telephone handset can be attached using
RJ-11 phone cable. This can be useful for manual dialing or troubleshooting.
17
SUPPORT LINK
Support Link Rear Panel
SUPPORT LINK II
EIA RS-232C
Connector ~~
115 Vac
Outlet
Jack
18
HP37212B
В gp oa aa UT TT - , y =r
AEG TH ee ENT. t IER SES FETURY
IO. + aaa |
ES IX IE
Er DR " po - E - % - . - a
py *
В bo
+
HP 37212B Rear Panel
HAYES SMARTMODEM 1200
POWER Examinatheback panel of the Smartmodem 1200 unk
SWITCH for identification of the connectors, power switch, and vol ume control.
RE aT RIT а LE
Mi ETT EEE
a EL ES DEL La € TA EARL
+ nu
EH IIR 1 UBER
i
POWER POWER RS-232C | TELEPHONE |
SWITCH CONNECTION CONNECTION CONNECTION CONTROL
В KNOB
19
ARIES E .
Modem to Terminal Cable:
‘Use a 40242M, 13242N or similar cable while configuring the Support Link II modem with a terminal. O
This cable is a straight through, 25-pin cable.
Remote Diagnostic Interface Cables (Serles 64, 68 and 70 computers):
There are two ports on the Remote Diagnostic Interface. One is labeled TO MODEM and the other is
labeled TO MODEM PORT. Your modem will be connected to the port labeled TO MODEM with the
30062B cable. A jumper cable connects the standard modem port (ldev 21) to the port labeled TO
MODEM PORT. Both of these cables are shipped with the HP modem. The use of the Remote Diagnostic
Interface is for parallel console which allows the Response Center to access the system console.
PHONE OPTIONAL REMOTE SUPPORT MODEM
a [0 бо = h
| Wu ]
— |
MELDED JUMPER CABLE i MODEM
MODEM CABLE PORT
= a | O
EEN
CLAGMOETE
INTERFACE
1000
OME
JCA
Connection of the Remote Support Modem through the
Remote Diagnostic Interface
20
PHONE NUMBERS:
HP Trend:
To configure the Response Center Dialup number in the CUSTINFO program, use the following format in
response to the RC DIALUP # prompt:
MODEM - a PHONE FORMAT
| SUPPORT LINK 9K 141 59687452
SUPPORT LINK II 9K14159687452
HP37212B T9%14159687452
HAYES 1200 T9,14159687452
where:
"9" is a typical character used for phone systems that require an access code
to place an outgoing call. |
"K" and "4" and "," are delay characters (typically used to wait for dialtone).
"T" 18 for tone (use "P" for pulse).
"1" is for phone systems that require a | to make a long distance call.
Predictive Support:
To conf igure the Response Center Dialup number in the PSCONFIG program, use the following format in
response to the RESPONSE CENTER DIALUP * prompt:
MODEM PHONE FORMAT
SUPPORT LINK 9K18002588884
SUPPORT LINK II 9K18002588884
HP37212B ‚ то%18002588884
HAYES 1200 T9, 18002588884
where:
“9" is a typical character used for phone systems that require an access code
to place an outgoing call. '
"K" and "%" and "" are delay characters (typically used to wait for dialtone).
21
"Т" 16 for tone (use "P" for pulse).
"1" is for phone systems that require a | to make a long distance call. O
(If your area is unable to use the toll-free 800 number, use 1-415-968-3902.)
CONCLUSION
The configurations recommended in this Application Note apply to MPE V/E
systems only. Contact your Customer Engineer or the Response Center
for recommended configurations for MPE XL systems.
22
NOTES
NOTES
NOTES
BACK ISSUE INFORMATION
Following is a list of the Application Notes published to date. If you would like to order single copies of
back issues please use the Reader Comment Sheet attached and indicate the number(s) of the note(s) you
need.
Note # Published
1 2/21/85
2 10/15/85
3 4/01/86
4 4/15/86
5 5/01/86
6 5/15/86
7 6/01/86
8 6/15/86
9 7/01/86
10 7/15/86
11 8/01/86
12 8/15/86
13 9/01/86
14 9/15/86
15 10/01/86
16 10/15/86
17 11/01/86
18 11/15/86
19 12/01/86
20 1/01/87
21 1/15/87
22 2/15/87
23 3/01/87
24 3/15/87
25 4/01/87
26 4/15/87
27 5/01/87
28 5/15/87
29 6/01/87
30 — 6/15/87
31 7/01/87
32 7/15/87
33 8/15/87
34 9/01/87
34 10/01/87
35 10/15/87
34 11/01/87
36 12/01/87
37 12/15/87
38 1/01/88
39 1/15/88
40 2/01/88
41 4/01/88
“te. 7/15/88
43 7/15/88
44 88/01/88
45 8/15/88
46 8/15/88
Topic
Printer Configuration Guide (superseded by note #4)
Terminal types for HP 3000 HPIB Computers (superseded by note #13)
Plotter Configuration Guide
Printer Configuration Guide - Revised
MPE System Logfile Record Formats
Stack Operation
COBOL 11/3000 Programs: Tracing Illegal Data
KSAM Topics: COBOL's Index 1/0; File Data Integrity
Port Failures, Terminal Hangs, TERMDSM
Serial Printers - Configuration, Cabling, Muxes
System Configuration or System Table Related Errors
Pascal/ 3000 - Using Dynamic Variables
Terminal Types for HP 3000 HPIB Computers - Revised
Laser Printers - A Software and Hardware Overview
FORTRAN Language Considerations - A Guide to Common Problems
IMAGE: Updating to TurboIMAGE 8: Improving Data Base Loads
Optimizing VPLUS Utilization |
The Case of the Suspect Track for 792X Disc Drives
Stack Overflows: Causes & Cures for COBOL II Programs
Output Spooling
COBOLII and MPE Intrinsics
Asynchronous Modems
VFC Files
Private Volumes
TurboIM AGE: Transaction Logging
HP 2680A, 2688A Error Trailers
HPTrend: An Installation and Problem Solving Guide
The Startup State Configurator | |
A Programmer's Guide to VPLUS/ 3000
Disc Cache
Calling the CRE ATEPROCESS Intrinsic
Configuring Terminal Buffers
Printer Configuration Guide
RIN Management (Using COBOLII Examples) (A)
Process Handling (Using COBOLII Examples) (B)
HPDESK IV (Script files, FSC, and Installation Considerations)
Extra Data Segments (Using COBOLII Examples) (C)
Tips for the DESK IV Administrators
AUTOINST: Trouble -free Updates
Store/ Restore Errors
MRJE Emulates a HASP Workstation
HP 250 / 260 to HP 3000 Communications Guidelines
MPE File Label Revealed - Revised 6/ 15/88
System Interrupts |
Run Time Aborts
HPPA Pathing Conventions For HP 3000 900 Series Processors
Vplus & Multiplexers
Setting Up An HPDesk/ HPTelex For The First Time
47
48
49
50
57
52
53
54
55
56
57
58
59
60
61
62
63
9/15/88
11/15/88
12/01/88
12/15/88
1/01/89
1/15/89
2/01/89
4/01/89
4/15/89
5/01/89
6/15/89
7/01/89
8/01/89
9/01/89
10/15/89
11/15/89
1/15/90
Customizing Database Data Items & Changing Passwords in JCL Files
Printer Configuration (Revision #4)
Configuring DAT ACOMM Products Into MPE
VFC's For Serial Printers
Terminal Types For The HP 3000 HPIB Computers
Configuring MRJE
Using Special Characters on the 700/9x Series Terminals
Improving Database Performance
Customized Message Catalogs And Help Facilities
BRW Tips For Beginners
Configuring The HP 2334A Plus & Hp 2335A As A Statistical Multiplexer
HPPA Pathing Conventions For HP 3000 900 Series Processors (U pdate)
HP 2334A and HP 2335 Configuration Recipes
TurboIMAGE's I-FILES and J-FILES
HPDeskManager - Looking Behind The Scenes
Setting Up A System Dictionary
Configuring Telesupport Modems For MPE V/E Systems
Is the format of this Application Note convenient in size, arrangement and readability? [] Yes [] No
READER COMMENT SHEET
Worldwide Response Center Support |
HP 3000 Application Note 63: Configuring Telesupport Modems For MPE v/ E Systems
(January 01, 1990)
We welcome your evaluation of this Application Note. Your comments and suggestions help us to
improve our publications. Please explain your answers under Comments, below, and use additional pages
if necessary. | |
Is this Application Note technically accurate? | a Yes [] No
Are the concepts and wording easy to understand? | | —[) Yes [] No
Comments and/or suggestions for f uture Application Notes:
This form requires no postage stamp if mailed in the U.S. For locations outside the U.S., your local HP
representative will ensure that your comments are forwarded.
—
FROM: | - В o Date
Name
Company
Address
FOLD | FOLD
NO No POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
MO A
BUSINESS REPLY MAIL
—
I
—
FIRST CLASS PERMIT NO. 95, MT. VIEW, CA —]ÉÚ]—
СВ ПБУ АВА 9 ERE EEE
POSTAGE WILL BE PAID BY ADDRESSEE
Application Note Comments
Hewlett-Packard Manufacturing Specifications
690 E. Middlefield Road
Mail Stop 30-0
Attention: AN ORDERS
Mt. View, CA 94043
FOLD | | “ FOLD
Document P/N #5959-7834 | a January 15, 1990
CA Packano Response CENTER QUESTIONS & ANswERS
HP 3000 Questions Commonly Received by the Response Centers
Q. What does it mean, when the RPG compiler sends the error message "06 T ENTRY OR HEADER
SPACE OVERFLOW IN USL FILE" in RPG Version A. 08.00?
A. This error may be produced due to large tables/arrays in your program.
In previous versions the compiler may not have checked correctly as to whether there was enough
space for the data in the USL file. As a consequence, the PREP aborted due to the errors contained in
the USL file.
‘To eliminate error 06, a larger USL file must be used (refer to the RPG Reference Manual, part
number 32104-90001, Appendix 3, page 4. If this does not help you must reduce your tables/arrays. -
E E RELRERLER REL RELLEL +
Q. When using the FORM command in Query, the ITEMS/SETS that were entered in the data base
— using DBCHANGE are not displayed. What is the reason for this?
A. After having entered ITEMS/SETS in the data base using DBCHANGE, you must set the ITEM/SET
SECURITY for these ITEMS/SETS in the SECURITY SCREEN. Otherwise, the system will create an
empty list for the read and write capabilities ("(/)") by default. In this case, only the CREATOR of the
data base has access capabilities.
* E E * & * * * + + & & & * à* * & * * & + * % + &
Q. What could cause an error message that appears to have nothing to do with the MPE command just
entered?
À. You must be certain that you did not enable a UDC command that has the same name as the
above-mentioned MPE command.
E E E E E E E *% % + + & + % + + * + % &
Q. Is it possible to create labeled tapes with the MPE /XL STORE command?
While trying to access labeled tapes with the usual MPE/V STORE on XL the following error
message: UNSUPPORTED DEVICE ACCESS STORE /RESTORE ERROR 496 was received.
A. To create labeled tapes add to the XL STORE command the option ;TRANSPORT
Q.
A.
Q.
* * * * à * * à * * * * % * * à % à +
How can a self-written TERMTYPE FILE be connected to the list file of a special application ?
Before running the application the following file equations must be entered:
(TTXY.PUB.SYS is the new TERMTYPE FILE)
FILE ENVFILE=TTXY.PUB.SYS ; LOCK
FILE listfile;DEV=list device ldev#;ENV=%ENVFILE.
EEERERRE RE RL RR ERE ERE
Is there a way to find out, which forms are allocated to which program (program = subsystem, e.g.
ENGINEERING-DATA in MM, SC in PM or MNTPIC in MNT)? This may be relevant, when you
want to know how many pooled processes must be defined for the individual subsystems and which
subsystem contains the forms that are most frequently used.
The dataset COMMAND-MAP in the data base TIPDB of the Tools Account provides information on
what form is allocated to what subsystem. The field COMMAND contains the form name and the
field SUBSYS the corresponding subsystem name. Use QUERY to create special reports on that subject.
*% % % à * * %* * à à * * * * à * à * * *
How can data records be written from a COBOL program without transferring a "CARRIAGE
RETURN"?
To write data records from a COBOL program to a file without transferring the CR of each write, the
intrinsics FOPEN and FWRITE must be used in connection with the following actions:
1. The carriage control directive must be enabled by setting the 7th bit in the FOPTIONS of the
intrinsic FOPEN to 1
2. The CONTROL parameter of the intrinsic FWRITE must be set to #320 (octal).
* * * * à à * * * * * * * * * % * à k
When creating RDIC files using RDIC3000. PUB.SYS the RDIC file does not contain all PARENT
elements, although it was indicated that all elements shall be included. What is the reason for this?
A. This is the case, when the DICTIONARY contains the following relationship:
PARENT
<1> CHILD1
<-2-> CHILD12
<1> CHILD?
<-2-> CHILD21
<-2-> CHILD22
RDIC 3000 only includes the elements of the highest and the lowest levels (in ¢ our example: PARENT,
CHILD12, CHILD21, CHILD22).
E E * + + + + E E + + + + + + + + + + +.
Q. How can the MPE/XL console messages saved in the system log files be reviewed ?
A. To view these files perform the following:
: SYSDIAG
DUI> RUN LOGTOOL | | |
LOGTOOL> STATUS (displays the system log files,
e.g...L0G0006,L0G0007,L0G0008,...)
LOGTOOL > TYPES (displays the different types of
loggings, e.g. 115 for console
logging)
LOGTOOL> LIST LOG=6/7 Ш ТУРЕ =1 15
| | |
(system log files (console messages )
LOG0O006/L0G0007 are po
investigated)
% + E + E + + E + E + E + + E + + + + +
—£ Q. When starting COBOL applications after an MPE release update, the error message UNRESOLVED
PROG EXTERNALS SL BINDING ERR may appear. What is the reason for it?
во O A. In the MPE V release Vdelta4 and MPE XL release A. 20.00 or later the COBOL 68 procedures are
В obsolete; they are no longer resident in the SL.PUB.SYS. However, in order to give access to these
- progedures : to. programs - using them, the obsolete software was put into the USL file
COB6 8LIB: PUB. SYS. | |
If one of your COBOL - applications aborts with the error described. above you should proçeed as
fot lows:
1) ‘Create an SL in the group of your application (if a SL does
а not yet exist) |
‚ ” E
me AE
- RUE
Q.
A.
2) Add the USL file COBEBLIB.PUB.SYS to this SL via the
SEGMENTER
3) Run the application with ...¿LIB=G.
+ & + * * * + * à * * * * + + * * * * +
When using V-Delta-4, V-Delta-5 and MPE/XL 1.2, the SL.PUB.SYS does not contain any
COBOL 68 segments. What effect does this have on MPD products?
If you use the MPD applications MM 3000, PM 3000 or MNT 3000 with one of the above-mentioned
operating system versions, you will encounter problems due to missing COBOL 68 segments in the SL of
the Tools Account.
The MRP in MM3000 may for example abort with the following error message:
PEC 752
LIEC 16
LFSEC O FAILURE TO START SUCCESSIVE PROCESS.
A request for Customizer reports will lead to the message UNRESOLVED EXTERNAL
REFERENCES’
Therefore, the following procedure must be carried through, in order to add the missing segments:
1. All users must be logged off, so that no user has access to
the Tools Account.
2. Log on to the Tools Account and continue as follows:
: HELLO MGR. <TOOLSACCT >, PUB
: SEGMENTER
-USL COBESLIB. PUB.SYS
-SL SL
-ADDSL COBLIB14
-EXIT
You may also contact the Response Center as they can supply you with an installation job for this
problem.
After this the MRP and the Customizer reports may be started without any problems.
E * * * E E E + E E E E * + + * + * + +
Q. What does the IMAGE DBOPEN condition code -204 mean?
A. The return of this undocumented condition code is caused by a STACK OVERFLOW. Since the MPE
release UBMIT, the DBOPEN procedure in special situations, especially during the recovery after
system failures, requires at least an extra of 1488 words to expand the stack. The CC is set to -204 in
the case where stack space 1s lacking.
To avoid this abort of an application, you should run it with the options :MAXDATA or/and ¡NOCB.
E 4 + de + E 4 E + + 4% + + 4 + % 4 + +4 +4
Q. How can the current software version of your application be determined?
A. When working on problems and questions in connection with your application, we often ask you to
give us the current version of your application. The following shows how to determine current
“versions: '
1. Application version
To determine the current Application Version log on as MGR in the application account and display
the file VERSNID in the editor. The commands are as follows:
: HELLO MGR.MM3000
| | :RUN EDITOR.PUB.SYS
O — /T VERSNID
/L ALL
| 1 HP32260A.09.07 PUB HP32265
2 HP MATERIALS MANAGEMENT
T he first line shows the product number HP32260 followed by the current MM3000 version A. 09.07.
2. Tools version
| | The Tools Account version may be determined’ by starting the program VERSIONP with the
_ following command:
| :
HELLO MGR.MM3000
o a :RUN VERSIONP.SYSPGM, <TOOLSACCOUNT> ; LI B=G
BR | НРЗ2265А. 03.06
| Your screen now displays the product number for Tools (HP32265) together with the current
- version A. 03. 06. . |
> - В
Lu a =
3. MPE/V version
The current version of the operating system may be determined using the SHOWME command:
: SHOWME
USER: #1373 ,MGR.MM3000
SYSTEM: HP3203G.A3.01
Behind the colon of the second output line you see the product number of the operating system
followed by the current version A 3.01.
EE EA AE EA» E» 4% +
Q. How can the CHANGE FILES created by DBCHANGE be purged? (They have the data base name
followed by the Appendix CF and the file code PRIV.)
A. To purge these files enter the DBUTIL subsystem and type
>>PURGE <databasename>CF
* * * * * * à à * * * * à + + + * * * +
Q. How can profile changes carried through in the NMMGR subsystem (e.g. in order to connect a new
printer to a DTC) be enabled on a 3000/XL system?
A. After creating the new profile, perform the following actions:
1) Run VALIDATE in the NMMGR
2) Enter SYSGEN, then SYSFILE and type RDCC (hold, keep, exit)
3) START NORECOVERY
4) DOWNLOAD of the DTC (turn off and on)
* * * * * * * * * * * * + + + + * * * *
Q. As far as XL systems are concerned, what is the meaning of files having a data base name followed
by the Appendix GB (<data base name>GB)?
A. On MPE/V the data base control blocks are always put into extra data segments. Since MPE/XL does
not know extra data segments, the control blocks are written into MPE files. One of these files is <data
base name>GB containing the DBG control block. It is created during the first DBOPEN on the data
base and purged after the last DBCLOSE. Therefore, the -GB file can only be seen, when the data base
1S 1n use. |
de * * * * %* * * * * * à %* & * & % * à à
Q. How can the MPE / V System Library $ SL. PUB. SYS be expanded?
A. To expand the system library perform tl the following actions:
1. .Log on as MANAGER.SYS
2. SEGMENTER
-SL SL
-COPYSL (value of expansion in %),NEWSL
3. FILE SL.PUP.SYS=NEWSL
FILE T;DEV=TAPE
4. SYSDUMP #T
ANY CHANGES? YES
нее | (CR until ..)
. SYSTEM SL CHANGES? YES . —-.—. |
(CR until end)
5. UPDATE with the tape created by SYSDUMP
E de %* * * * E de * * + 4 * * E E 2 4 + +
Q How can BRW Reports be transmitted from an и МРЕ/У V to an MPE/> XL system (compatibility mode)?
A. Save the following files on the MPE/ V system and transmit them to the MPE/ XL system:
1. All data files
2. All Report Execution files (code REXEC)
, | 3. All Report Specification files (code RSPEC)
4. All Report Job files (RJOB files) |
5. All configuration files (RCONF files)
Refer to the BRW/XL Manual, part number 35360-60002 Appendix F, page 4.
E ERERÁERÁXELXÁXELTTXELETELE
Q: When adding up two arrays, only the first two elements are taken into account. What is the reason
for this?
A. This happens, whenever result indicators are used during addition. The addition will be performed
correctly, 1f these result indicators are not used.
Until Version 08.03 of RPG it was possible to use result indicators during arithmetic operations,
although this was not provided by the manual. Starting with Version 08.03 the use of result
indicators is suppressed by the RPG compiler. If result indicators are used in a program during
arithmetic operations, the following message appears:
633 Indicators in Col. 54/59 not allowed for this
operation. Assume blank.
* * * * * * * * * * à * * à à * * à + +
Q. How can BRW reports be transferred from an MPE/V to an MPE/XL system (Native Mode)?
A. BRW reports may be transferred by using the following procedure:
1. Save all data (files used/data bases, dictionaries, specification files, report job files (RJOB),
configuration files) on the MPE/V system and transfer it to the MPE/XL system.
2. Create a BRWDIC file using the program BRWD3000.PUB.SYS, BRWAPPD.PUB.SYS or
BRWSD. PUB.SYS. If MPE or KSAM files contain real numbers, this must be indicated in the
appropriate dictionary before the BRWDIC file is created. dDictionary/V --> adding the
LONGNAME IREAL-HP3000,; System Dictionary --> adding the ELEMENT-SUBTYPES
HP3000)
3. Rename the report job files (RJOB) so that they correspond to the file names used in BRW/XL.
4. Rename the RJOB files to BRWIJOB.
5. Rename the RCONF files to BRWCONF.
6. Compile the BRW/V reports using BRWXL or BRWCOMP. PUB. SYS.
Refer to the BRW/XL Reference Manual, part number 35360-60002 Appendix F, page 3.
* * * * * * + * + * + + * * + + * + à à
. How can BRW reports be transferred from an MPE /XL (Native Mode) to an MPE/V system?
‚ BRW reports may be transferred by using the following procedure:
1. Save all files (files/data bases, BR WJOB files, BRWCONF files) on the MPE/XL system and transfer
them to the MPE/V system.
2. Rename the BRWIJOB files so that they correspond to the file names used in BRW/V. Rename the
BRWIJOB files to RJOB.
3, Rename the BRWCONF files to RCONF.
4. Create the RDIC file (Dictionary --> RDIC3000.PUB.SYS; System Dictionary -->
RSYSDIC. PUB. SYS; Application Dictionary --> RAPPDIC.PUB. SYS)
5. Compile the specif ication files on the MPE/XL system using BRW or RCOMP. PUB. SYS.
6. Save the Report Execution Files on the MPE/XL system and transfer them to the MPE/V system.
Refer to the BRW/XL Reference Manual, part number 35360-60002 Appendix F, page 5.
E E de + E E * + + * + + + + + * + + * +
Q. What must be done to update the fields UNIT -RUN-LBR-SID and SETUP -LBR -STD?
A. These fields are standard fields and are updated by the program PMS -COST-ROLLOVER. There 1s no
write access through a screen. The fields are only used for documentation and accounting purposes and
not for scheduling.
+ + + + + + à + # à & à à à & à à à à +
Q. How does the program PUR. COMMITMENT calculate the value of the field REM-COMMITMENT?
A. The program PUR.COMMITMENT creates a list of all orders left to receive together with the dates,
at which the orders will become due. The program creates the file IOS1600 that contains records from
the datasets PURCH-ORDER-DTL and ITEM-DATA. The calculation of the field
REM- COMMITMENT depends on whether the value of the field PRICE -PO is zero or greater than
Zero.
If the value of the purchase price is greater than zero, the following calculation will be carried
- through:
REM-COMMITMENT = PRICE-PO x QTY-LEFT-TO-REC
If the value of the purchase price is equal to zero, the calculation is carried through on the basis of
the ITEM-DATA records and would then look like this:
REM-COMMITMENT = STD-UNIT-COST x QTY-LEFT-TO-REC
Please note that the value of the field STD-UNIT-COST 1s the sum of the field values
STD-MATL-COST, STD-LBR-EXP-RATE, STD- TL-OVH-COST, STD-LL-LBR-COST and
STD-LL-OVH-COST.
E E RERRRRERRRRERRREXLTLE
Q. When scheduling orders, which of the two queue times (operation or workstation queue time) shall be
taken into account?
A. The scheduling of orders is based on the queue time from the WORK-STATION dataset. The
operation queue time (OPERATION-MSTR) is used as a field containing helpful information for the
person in charge of the order scheduling, as this queue time may make up for the biggest share in the
total order turn- around time.
* * & & * * * * + * * * + * * * * * * *
Q. How may an SAI terminal be restarted after abortion?
A. If a pooled SAI terminal aborts and the message
"Desired function not available now TIPERR 1239"
appears, the terminal may be restarted using the START-UDC. If START is entered after the MPE
prompt, the START-UDC 1s activated and the following message is displayed:
"Please enter the name of the terminal to be started"
This message must be answered by indicating the appropriate terminal name, that is SAI terminal).
Enter // to close your message. Please note that you must be logged on to the appropriate application
account.
Your terminal is defined as a pool terminal, if it is allocated the logical device number 1. The device
number is contained in the Customizer. However, it can also be checked using the CHGTERM-UDC.
* * * * & * * * * * à #% * * + * * à * à
О. What consequences has a !'COMMENT SDEBUG in case of a job abortion?
A. If a program aborts without a precise error message and the abortion message on the SAI terminal is
not sufficient to tackle the problem, the Response Center Engineers often recommend to include a
ICOMMENT $DEBUG in the first line of the appropriate JCL. $DEBUG is a special monitor
command that instructs the monitor to print the appropriate JCL in its whole length. The printout
shows at what step the program aborts. In addition, a supplementary error message 1s displayed. The
ICOMMENT $DEBUG entry should be withdrawn from the JCL afterwards. Otherwise, a job listing 15
created on every program run that calls the corresponding JCL.
RRRRRERRRERER RENE
Q. VINIT >COND does not always provide larger fragments of free disc space. What is the reason for
this?
A. VINIT >COND scans the used disc fragments in ascending address order and tries to place each of
these fragments onto a fragment of free disc space having a LOWER address.
Example 1
Free 1 Free 2 . Free 3 <= —. Free 4 .
— Used 1 Used 2 Used 3 a Used 4
RUNNING VINIT >COND +
1) Used 1 cannot be moved.
2) |----||------- | |-----0——— | 1---|
Free 1 Free 2 Free 4
Used 2 Used 1 Used 3 Used 4
3) |--=-||------- | =m mmm | |---|
Free 1 | Free 4
Used 2 Used | Used 3 Used 4
4) |----]]-------]--=---==--—- ET |
Free 1 Free 4
Used 2 Used 1 Used 3 Used 4
Example 2 (no larger fragments of free disc space are
created):
| deL [eee | =m mmm | |---==-==----- |
Free 1 Free 2 Free 3 Free 4
Used 1 Used 2 о Used 3 Used 4
RUNNING | VINIT >COND
It is ‘obvious that none of the used areas can be moved onto a free fragment having a LOWER address.
Therefore, no changes are made.
* * * * * * * * * * * + + + + * * + + +
Q. How can STDIN and STDLIST of a program started in a job be directed to a terminal?
A: To direct it to a terminal you should create the following job:
tJOB DEMOJOB,user.account
*FILE X,NEW;DEV=1dev #;SHR;MULTI ; ACC=INOUT
‘FILE Y;DEV=1dev #;SHR;MULTI
!RUN DEMOPROG.group.account ;STDIN=#X;STDLIST=#Y
'EOJ
NOTE
Make certain that the terminal to be used as STDIN and STDLIST is not
occupied by a session.
E E E + E E de $ E 4 % 4 % € 4 % 2 kA
Q. As far as MM, PM, MNT, HPFA, HPFB and HPPO are concerned, what groups are contained in the
Tools Account and what are they used for?
A. The following groups must always be present:
- PUB
- SYSPGM
Depending on the application used, the following product- specific groups must be available:
MM
_ HP32260 MM programs |
PM | ‘
- HP32270 PM programs
MNT
- HP32276 MNT programs
я AE
Tog FE
CAES
3
.
»
3
HPFA
= HP32304
- HP32305
- HP32307
- HP32308
- HP32309
- HP32310
- HP32311
- HP35300A
- HP35350A
HPFB
HP32310
HP32311
_ HP35300A
HP35350A
tt ¡
HPPO
- HP34006
general moduls
general ledger
allocator
accounts payable
accounts receivable
report facility
interface facility
max programs
financial budget files
report facility
interface facility
max programs
financial budget files
HPPO programs
">
/
Download