MoTorS, coNTrolS aNd drivES

Tested. Tough. Proven.

From the dawn of civilization, providing and managing a dependable source of water has been essential to mankind's survival. Serving this most basic human need has driven the development of countless new technologies. In the 21st century,

Pentek

®

is at the forefront of developing new and better electronic technology for water management.

Pentek will continue to bring you new innovations in motors and controls, because of our rich heritage of expertise in water management systems. Pentek is the leading electronics brand of Pentair, North America's largest water pump manufacturer. Pentair sets demanding standards for pumps, motors and controls that are labtested and field-tested, to prove they're tough enough, before they ever ship to our customers.

We start with the fact that our motors, controls and other products have to be exceptionally tough. Submersible pumps live deep inside a difficult environment, and only a tough motor with a hard-working, precision-engineered control system can meet the constant demand for water.

Where technology must be tough, Pentek has been tested and trusted by our customers.

Pentek offers the exceptional technical support you expect from Pentair, and a level of advanced “tough technology” unmatched in the industry. So, demand more, and put us to the test. Our vision is to prove, time and time again, we are your best choice.

Table of Contents

4" SUbMErSiblE XE MoTorS

Materials of Construction, Dimensional Data

Features & Benefits

Technical Data

Coal Bed Methane

4" Submersible Motor Adapter

4" SiNGlE-PHaSE MoTor coNTrolS

Single-Phase Controls, CSIR, CSCR, VIP Pro

PUMP ProTEcTioN

Single-Phase Protectors

SPP-111P & 231P

SPP-111P-3RL, SPP-233P & 235P

The Informer

6" SUbMErSiblE MoTorS

Features & Benefits

Materials of Construction, Dimensional Data

Hitachi

®

Submersible Motors

Hitachi Control Boxes

Technical Data

1/2 – 10 HP

1/2 – 5 HP

1/3 – 1 HP

1/2 – 15 HP

5 - 50 HP

8"- 14" SUbMErSiblE MoTorS

Features & Benefits

Materials of Construction, Dimensional Data, Technical Data

7-1/2 – 300 HP

THrEE-PHaSE STarTErS

PPX NEMA Pump Panels

drivE ProdUcTS

Pentek Intellidrive

1/2 – 3 HP

Pentek Intellidrive Accessories

PPC3 & PPC5 1/2 – 200 HP

PPC Selection Guide

28

28-31

32-35

36,37

38,39

accESSoriES 40

Reactors & Filters 40-42

Transducers, Leads & Repair Parts 43

NoMENclaTUrE aPPENdiX 40

24

24

25

26

26,27

16

16

17

18

19

20

20

21

22

23

23

8,9

10

11

4

5

6

12

12-15

4

4" submersible motors

4" Submersible Motors

XE-SERIES

For high-thrust water well applications

1/2 − 5 HP, Single Phase, 2 & 3 Wire, 115V and 230V, 60 Hz

1/2 – 10 HP, Three Phase, 3 Wire, 200V, 230V, 460V and 575V, 60 Hz

Pentek

®

offers a complete line of XE Series 4" Submersible

High-Thrust Motors. Built with the latest design, manufacturing, and testing technology, they feature laser-welded 304L stainless steel construction, higher-thrust capacities and higher efficiencies.

4" submersible motors

XE-SERIES

Engineered EPOXY STATOR Design

The Pentek

®

XE Series submersible motors utilize a 304L stainless steel “encapsulated, epoxy stator design,” and professional-grade Class F insulation providing longer life in harsh environments. Each motor is 100% factory pressure and run tested to support our high quality standards.

Features

Pentek submersible motors are unique in providing the industry with innovative and robust design features that will extend the life of your installation:

Oversized Kingsbury-type Thrust Bearing Design–

Large high-performance bearings are standard on all HPs allowing for higher thrust loads, providing many years of trouble-free service under severe-duty operation

2-Wire Permanent Split Capacitor Design insures quiet operation and improved operating efficiency

3-Wire Motors operate with Pentek SMC-CR,

VIP Pro and Pentek Intellidrive

products

All Stainless Steel Exterior

Professional-Grade Class F-Compliant Motor

Insulation – Allows for longer service life

100% Factory Pressure and Run Tested

Automatic Thermal Protection on 2-wire designs to 1-1/2 HP models and 3-wire designs to

1 HP single-phase

All 115V and 230V motors are equipped with surge arrestors to provide maximum protection against lightning, transient and voltage surge conditions

Technical data can be found on page 8

Mounting Configuration

“L”

1.50”

(38.1mm)

3.00”

(76.2)mm)

3.75”

(92.25mm)

14 Teeth 24/48 Pitch

30 º Pressure Angle

Min. 0.50 Full Spline

ANSI B92.1 Compliant

0.91”

1.5”max

(4) 5/16-24

UNF-2A Threaded

Studs on 3” Dia. Circle

Materials of Construction

ParTS MaTErialS

End Bell 304L cast stainless steel, rounded bottom

Shell

Motor Shaft

Insulation

Max. Water Temp.

304L stainless steel, laser-welded to end bells

17-4 precipitation hardened SS

Class F, 311°F (155°C)

86°F (30°C)

Fasteners

Lip Seal

Sand Boot

Cable

Cable Length

304-grade stainless steel

Nitrile

Nitrile

Field-serviceable, controlled compression design

UL, CSA, NSF approved

48" - 1/2 HP to 1-1/2 HP; 100" - 2 HP and above

Diaphragm EPDM

Thrust Bearings

Thrust Load Capacity

Kingsbury-type, pivot shoe, carbon graphite mating ring

Varies by rating. See table on page 8

Consult Pentek Electronics Manual for high-temperature applications

0.6255”

0.6245”

Sand

Boot

P 8111 WS

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

6

4" SUbMErSiblE MoTorS

4" Submersible Motors

XE-SERIES

Innovations focused on dependable performance

Capacitor

Patented encapsulated toroidal capacitor on

2-wire motor design provides smoother, noise-free operation without the need for a control box

Lower starting current with both main and start windings engaged at all times

Motor End Bells & Shell

Upper & lower 304L stainless steel (SS) end bells are designed for 100% corrosion-resistance and durability

Rounded bottom on lower end bell reduces well casing interference

Upper 304L SS end bell is designed with internal cord entry feature

Motor shell is constructed of 304L SS tubing, with a laser-etched nameplate and warning label

Motor Leads

Replaceable lead is held in place by 2 screws for controlled compression

Each lead is tested twice to 250 PSI

UL, CSA, NSF approved

Kingsbury-type Thrust Bearings

Large high-performance bearings are standard on all HPs, allowing higher thrust loads, for many years of trouble-free service under severe-duty operation

Stainless steel pivot shoe is securely positioned over the carbon graphite disk for even load disbursement

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

4" submersible motors

XE-SERIES

Class F Insulation

Professional-grade Class F-compliant motor insulation allows for longer service life and more reliable motor operation

Surge Arrestors

Surge arrestors are mounted within the upper end bell

Design provides each conductor circuit with its own surge arrestor

Designed to optimize clamping voltage, energy absorption/dissipation and response time

Drive Shaft

17-4 precipitation hardened stainless steel shaft with precision finished bearing surfaces

NEMA standard mounting and shaft height

Sand Slinger

Provides ultimate protection against sand and grit intrusion

Stamped stainless steel upper cover is designed to prevent sand entry

7

4" submersible motors

4" Submersible Motors

For high-thrust water well applications — 1/2 - 10 HP, single- and three-phase

8

MOTOR

TYPE

PSC

2-WIRE

RaTINg

CaTaLOg

NuMbER

P42b0005a1

HP

1/2 kW VOLTS

0.37

115

P42b0005a2

P42b0007a2

P42b0010a2

P42b0015a2

P42b0005a1-01

P42b0005a2-01

P42b0007a2-01

1/2

3/4

1

1 1/2

1/2

1/2

3/4

0.37

0.55

0.75

P42b0010a2-01 1 0.75

P42b0015a2-01 1 1/2 1.1

1.1

0.37

0.37

0.55

230

115

230

230

230

230

230

230

230

60

60

60

60

60

60

60

60

60

HZ

60

CSIR

3-WIRE

CSCR

3-WIRE

P43b0005a1

P43b0005a2

P43b0007a2

P43b0010a2

P43b0005a1-01

P43b0005a2-01

P43b0007a2-01

P43b0010a2-01

P43b0005a2

P43b0007a2

P43b0010a2

P43b0015a2

P43b0020a2

P43b0030a2

P43b0050a2

3/4

1

1 1/2

2

3

5

P43b0005a2-01

P43b0007a2-01

1/2

3/4

0.37

0.55

P43b0010a2-01 1 0.75

P43b0015a2-01 1 1/2 1.1

0.55

0.75

1.1

1.5

2.2

3.7

1/2

1/2

3/4

1

1/2

1/2

3/4

1 0.75

1/2 0.37

0.75

0.37

0.37

0.55

0.37

0.37

0.55

230

230

230

230

230

230

230

230

230

230

230

115

230

230

230

230

115

230

230

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

1.4

1.6

1.6

1.5

1.4

1.6

XE SERIES PERFORMANCE

SERVICE

FaCTOR

1.6

1.3

1.6

1.6

1.5

1.6

1.5

1.4

1.4

1.3

1.6

FuLL LOad aMPS

7.4

9.2

7.9

4.0

5.0

3.7

5.0

7.9

6.7

9.0

Y/B/R

11.0/11.0/0

Max. LOad (SF

LOad) aMPS

9.5

11.0

9.8

4.7

6.2

4.7

6.4

9.1

8.1

10.4

Y/B/R

12.6/12.6/0

MaIN

RESISTaNCE

1.3-1.8

WINdINg

STaRT

RESISTaNCE

4.5-5.2

3.0-4.8

4.2-5.2

1.9-2.3

1.4-2.0

6.1-7.2

5.9-6.9

4.2-5.2

1.8-2.4

0.9-1.6

5.7-7.0

1.6

1.5

5.5/5.5/0 6.3/6.3/0 4.2-4.9

2.6-3.6

17.4-18.7

11.8-13.0

7.2/7.2/0

8.4/8.4/0

8.8/8.8/0

5.3/5.3/0

6.6/6.6/0

8.1/8.1/0

8.3/8.3/0

9.7/9.7/0

10.9/10.9/0

6.1/6.1/0

7.8/7.8/0

9.4/9.4/0

2.2-3.2

1.0-1.4

5.1-6.1

2.6-3.3

2.0-2.6

4.2-4.9

11.3-12.3

2.5-3.1

12.4-13.7

10.4-11.7

9.3-10.4

17.4-18.7

1.6

1.5

1.4

1.3

1.5

1.4

1.3

1.25

1.15

1.15

4.1/4.1/2.2

5.1/5.0/3.2

6.1/5.7/3.3

9.7/9.5/1.4

9.9/9.1/2.6

14.3/12.0/5.7

24/19.1/10.2

4.2/4.1/1.8

4.8/4.4/2.5

6.1/5.2/2.7

9.1/8.2/1.2

4.9/4.4/2.1

6.3/5.6/3.1

7.2/6.3/3.3

11.1/11.0/1.3

12.2/11.7/2.6

16.5/13.9/5.6

27.0/22.0/10.0

4.8/4.3/1.8

6.0/4.9/2.3

7.3/5.8/2.6

10.9/9.4/1.1

2.6-3.6

2.2-3.2

1.6-2.3

1.6-2.2

1.1-1.4

0.62-0.76

5.1-6.1

2.6-3.3

2.0-2.6

2.1-2.5

11.8-13.0

11.3-12.3

7.9-8.7

10.8-12.0

2.0-2.5

1.36-1.66

12.4-13.7

10.4-11.7

9.3-10.4

10.0-10.8

32.0

41.2

47.8

49.4

76.4

101.0

41

49

21

32

41.2

44

21

32

41

22.3

49.6

22.3

32.0

LOCkEd

ROTOR aMPS

36.4

19.5

24.8

21.7

42.0

28

16

18

24

44

LENgTH WEIgHT

378

267

267

302

279

314

337

318

361

IN MM Lb

11.0

279 19.2

11.0

12.4

13.3

14.9

10.5

10.5

11.9

12.5

14.2

19.2

22.7

24.5

28.9

18.1

18.1

21.4

23.2

27.3

kg

8.7

8.7

10.3

11.1

13.1

8.2

8.2

9.7

10.5

12.4

THRuST

RaTINg

275

297

345

383

466

703

234

262

284

325

297

244

234

262

284

246

253

246

275

10.8

11.7

13.6

15.1

18.3

27.7

9.2

10.3

11.2

12.8

11.7

9.6

9.2

10.3

11.2

9.7

10.0

9.7

10.8

9.7

10.5

12.4

14.1

18.1

31.8

7.6

9.0

10.0

11.8

10.5

8.1

7.6

9.0

10.0

8.2

8.6

8.2

9.7

21.4

23.1

27.4

31.0

40.0

70.0

16.7

19.8

22.0

26.0

23.1

17.9

16.7

19.8

22.0

18.1

18.9

18.1

21.4

700

900

1500

MOTOR

TYPE

CSCR

3-WIRE

CaTaLOg

NuMbER

P43S0020a2

P43S0030a2

P43S0050a2

HP kW

2 1.5

3 2.2

5 3.7

COALBED MEthANE - XE SERIES PERFORMANCE

RaTINg WINdINg

VOLTS

230

230

230

HZ

60

60

60

SERVICE

FaCTOR

1.25

1.15

1.15

FuLL

LOad aMPS

(Y/b/R)

Max. LOad

(SF LOad) aMPS

(Y/b/R)

9.9/2.6/9.1 12.2/2.6/11.7

14.3/5.7/12.0 16.5/5.6/13.9

24/10.2/19.1 27/10.0/22.0

MaIN

RESISTaNCE

1.6-2.2

1.1-1.4

0.62-0.76

STaRT

RESISTaNCE

10.8-12.0

2.0-2.5

1.36-1.66

LOCkEd

ROTOR aMPS

49.4

76.4

101.0

LENgTH

IN.

MM

19.3

22.3

28.6

491

567

726

Lb

WEIgHT kg

47.0

53.0

74.0

21.3

24.0

33.6

THRuST

RaTINg

900

1500

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

4" submersible motors

XE-SERIES

Catalog

NuMber p43b0005a8 p43b0005a3 p43b0005a4 p43b0007a8 p43b0007a3 p43b0007a4 p43b0010a8 p43b0010a3 p43b0010a4 p43b0015a8 p43b0015a3 p43b0015a4 p43b0015a5 p43b0020a8 p43b0020a3 p43b0020a4 p43b0020a5 p43b0030a8 p43b0030a3 p43b0030a4 p43b0030a5 p43b0050a8 p43b0050a3 p43b0050a4 p43b0050a5 p43b0075a8 p43b0075a3 p43b0075a4 p43b0075a5 p43b0100a4

Motor type

3-phase

Motor type

3-phase

Catalog

NuMber p43s0030a3 p43s0030a4 p43s0050a3 p43s0050a4 p43s0075a3 p43s0075a4 p43s0100a4 hp

1

1

1 1/2

1 1/2

1 1/2

1 1/2

2

2

2

2

3

1/2

1/2

1/2

3/4

3/4

3/4

1

5

5

7 1/2

7 1/2

7 1/2

7 1/2

10

3

3

3

5

5

5

7 1/2

7 1/2

10 hp

3

3

5 kW

0.75

0.75

1.1

1.1

1.1

1.1

1.5

1.5

1.5

1.5

2.2

0.37

0.37

0.37

0.55

0.55

0.55

0.75

3.7

3.7

5.6

5.6

5.6

5.6

7.5

2.2

2.2

2.2

3.7

3.7

ratiNg

Volts

230

460

200

230

460

575

200

230

460

575

200

200

230

460

200

200

230

460

460

575

200

230

460

575

460

230

460

575

200

230 hZ

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

60

Full load aMps

4.0

2.2

6.3

5.2

2.8

2

7.5

6.5

3.3

2.7

10.9

3.8

3.3

1.7

4.6

2.9

2.4

1.3

7.6

7.0

27.0

24.0

12.2

9.1

15.6

9.2

4.8

3.7

18.3

15.7

serViCe

FaCtor

1.4

1.4

1.3

1.3

1.3

1.3

1.25

1.25

1.25

1.25

1.15

1.5

1.5

1.5

1.4

1.6

1.6

1.6

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

Max. load

(sF load) aMps

4.7

2.5

7.2

6.1

3.2

2.4

8.8

7.6

3.8

3.3

12.0

4.5

3.9

2.0

5.5

3.4

2.9

1.5

8.5

7.6

30.0

26.4

13.5

10.0

17.2

10.1

5.3

4.1

20.2

17.5

XE SERIES PERFORMANCE

liNe to liNe resistaNCe ohMs

4.1-5.1

17.8-18.8

1.9-2.5

2.8-3.4

12.3-13.1

19.8-20.6

1.4-2.0

1.8-2.4

8.00-8.67

9.4-9.7

0.9-1.3

4.1-5.2

5.72-7.2

23.6-26.1

2.6-3.0

3.3-4.3

14.4-16.2

3.4-3.9

1.3-1.7

5.9-6.5

9.4-9.7

0.4-0.8

0.85-1.25

3.58-4.00

3.6-4.2

0.5-0.6

0.55-0.85

1.9-2.3

3.6-4.2

1.8-2.2

loCked rotor aMps

26.1

13.0

40.0

32.4

16.3

11.5

51.0

44.0

23.0

21.4

71.0

22

17.3

9

32.0

27

14

29.0

48.0

55.0

165.0

140.0

87.0

55.0

110.0

58.9

30.0

21.4

113.0

93.0

3.7

5.6

5.6

7.5

kW

2.2

2.2

3.7

COALBED MEthANE - XE SERIES PERFORMANCE

ratiNg

460

230

460

460

Volts

230

460

230

60

60

60

60º hZ

60

60

60 serViCe

FaCtor

1.15

1.15

1.15

1.15

1.15

1.15

1.15

Full load aMps

9.2

4.8

15.7

Max. load (sF load) aMps

10.1

5.3

17.5

7.6

24.0

12.2

15.6

8.5

26.4

13.5

17.2

liNe to liNe resistaNCe ohMs

1.3-1.7

5.9-6.5

.85-1.25

3.58-4.00

0.55-0.85

1.9-2.3

1.8-2.2

loCked rotor aMps

58.9

30.0

93.0

48.0

140.0

87

110 leNgth

22.6

28.6

28.6

31.6

iN

19.3

19.3

22.6

573

726

726

802

MM

491

491

573 leNgth iN

11.7

11.7

11.7

11.7

11.7

11.7

13.8

13.8

13.8

15.3

15.3

10.8

10.8

10.8

11.7

10

10

10

21.7

27.7

27.7

27.7

27.7

27.7

30.7

15.3

15.3

15.3

21.7

21.7

MM

297

297

297

297

297

297

351

351

351

389

389

274

274

274

297

254

254

254

551

703

703

703

703

703

780

389

389

389

551

551 thrust ratiNg

700

900

1500

59

74

74

80 lb

47

47

59

Weight

26.8

33.6

33.6

36.3

kg

21.3

21.3

26.8

thrust ratiNg

900

1500

Weight lb

23.1

23.1

23.1

23.1

23.1

23.1

27.4

27.4

27.4

32

32

18.9

18.9

18.9

21.4

21.4

21.4

23.1

70

70

55

70

70

70

78

32

55

55

32

32 kg

10.5

10.5

10.5

10.5

10.5

10.5

12.4

12.4

12.4

14.5

14.5

9.7

9.7

9.7

10.5

8.6

8.6

8.6

24.9

31.8

31.8

31.8

31.8

31.8

35.4

14.5

14.5

14.5

24.9

24.9

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

P 8148 WS

9

4" submersible motors

4" Submersible Motors

Innovations focused on dependable performance

PENTEK

®

XE-SERIES

4” SUbMErSiblE MoTorS

The quality of the water-filled Pentek

®

XE Series 4” submersible motors has been proven through years of operation in the field.

The new Series features water-filled motors which are built for reliability in potentially contaminated

(sand or coal fines) well installations.

The Pentek XE Series gives you 40 different choices, including the new coal bed lineup:

230-Volt Single-Phase 2 to 5 HP

230-Volt Three-Phase 3 to 7.5 HP

460-Volt Three-Phase 3 to 10 HP

Pentek Severe Duty Series Motors are rated for continuous duty in 86˚ F water, and feature a silicon carbide mechanical seal and diaphragm filter to help prevent sand/debris entry.

10

Motor Dimensions

14 teeth 24/48 pitch

30˚ pressure angle

Min .50” full spline

Class A sliding fit

ANSI B92.1 compliant

DESCRIPTION

HP PHASE VOLTAGE

5

7.5

5

5

7.5

10

2

3

3

3

3

1

3

1

230

230

460

230

230

230

230

460

460

460

“LM”

In. (mm)

19.32 (490,7)

22.32 (566,9)

19.32 (490,7)

19.32 (490,7)

28.57 (725,7)

22.57 (573,3)

22.57 (573,3)

28.57 (725,7)

28.57 (725,7)

31.57 (801,9)

WEIGHT

(LBS.)

59

74

74

59

74

80

47

47

47

53

1.51

3.76

1.508

1.498

LM

Materials of Construction

ParTS MaTErialS

Upper bearing housing

Lower bearing housing

Shell

Stator ends

Shaft

Seal cover

Seal

Diaphragm

Slinger

Lead wire (or cable)

Lead potting

304L SS

Cast iron

304L SS

304L SS

17-4SS

Sintered bronze

SiC/SiC mech seal

Nitrile rubber

Nitrile butadyne rubber

XLPE

Epoxy

Lead screws/clamp

Filter

316 SS

Polyethylene

Specifications subject to change without notice.

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

4" submersible motors

4" Submersible Motor Adapter

For high-thrust water well applications

The PKG 4 x 6, Pump/Motor Adapter allows you to use a 6" motor to power your 4" submersible pump.

Applications

Water Systems... For residential, industrial, commercial, multiple housing and farm use.

Specifications

All Stainless Steel Construction – adapter casting, coupling, intake screen, beveled wire forms, socket head cap-screws, studs, and fasteners

Features

Extends Single-Phase Power Availability to 4" submersible pumps through 10 HP using 6" single-phase motors

Easy Assembly – Easy jobsite assembly

Double-Suction Screens – Reduces inlet suction velocity, reducing the amount of suspended solids ingested by pump

Patent #6, 398,521 B1

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK caTaloG

NUMbEr

PUMP

ENd

MoTor

MaXiMUM

HP

PKG 4X6 4" NEMA 6" NEMA 10

* The PKG 4 x 6, Pump/Motor Adapter Is Sold Separately

wEiGHT lbS.

5

11

12

4" SiNGlE-PHaSE coNTrol boXES

Submersible Motor Controls

Standard controls for single-phase 3-wire submersible motors

1/2 - 5 HP, Single-Phase Controls, 50/60 Hz

For Hitachi

®

Submersible Motors see pages 22-25.

Pentek

®

offers a full range of 1/2 - 5 HP models that are interchangeable with existing motor controls for Capacitor Start/Induction Run

(CSIR) and Capacitor Start/Capacitor Run

(CSCR) applications. Pentek is the professional choice in harsh and high temperature installations.

c b

Applications

Water systems…for residential, multiple housing, farm and commercial installations, where a submersible

3-wire motor is used.

Design Features

Enclosure

Rugged NEMA 3R Enclosure – suitable for indoor/ outdoor use

Multiple-Size Electrical Knockouts

Rated for 50 ° C (122 ° F)

internals

High-Load Voltage Relay

Heavy-Duty Contacts

External Access to Overload Reset – 1.5HP - 5HP

Heavy-Duty Terminal Connectors – suitable for up to #4 AWG wire

Industry Standard Wiring Connections – easy-to-read wiring diagrams

Overload Protection Built-in (50 Hz models)

agency approvals

CSA CUS Certified

Pentek Submersible Motor Controls can be used with

Pentek XE Series and other 4" single-phase motors.

a c US

Hitachi

®

is a registered trademark of Hitachi Industrial Equipment Systems Co., Ltd.

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

SIZE A

4.9

SIZE B SIZE C

4" SiNGlE-PHaSE coNTrol boXES

5.50

2.00

6.35

2.8

1.0

3.0

8.5

7.75

1.50

6.25

7.75

5.50

1.0

1.13

CSIR – Capacitor Start/Induction Run

HP Kw PHaSE volTS

1/2

1/2

3/4

1

0.37

0.37

0.55

0.75

1

1

1

1

115

230

230

230

lbS.

wEiGHT

KG

4

4

1.8

1.8

4

4

1.8

1.8

1.13

1.18

ENcloSUrE

SiZE

A

A

A

A

CSCR – Capacitor Start/Capacitor Run

HP

1/2

3/4

1

1-1/2

2

3

5

Kw

0.37

0.55

0.75

1.1

1.5

2.2

3.7

PHaSE

1

1

1

1

1

1

1

volTS

230

230

230

230

230

230

230

lbS.

wEiGHT

KG

5 2.3

7

7

5

5

7

8

2.3

2.3

3.2

3.2

3.2

3.6

ENcloSUrE

SiZE

A

B

B

A

A

B

B

60 HZ caTaloG No.

SMC-IR0511 (-6pk)*

SMC-IR0521 (-6pk)*

SMC-IR0721 (-6pk)*

SMC-IR1021 (-6pk)*

60 HZ caTaloG No.

SMC-CR0521 (-6pk)*

SMC-CR0721 (-6pk)*

SMC-CR1021 (-6pk)*

SMC-CR1521

SMC-CR2021

SMC-CR3021

SMC-CR5021

50 HZ caTaloG No.

-

-

-

-

50 HZ caTaloG No.

-

SMC5-CR0721

SMC5-CR1021

SMC5-CR1521

SMC5-CR2021

SMC5-CR3021

SMC5-CR5021

CSCR PLUS – Capacitor Start/Capacitor Run PLUS Magnetic Contactor

HP

2

3

5

Kw

1.5

2.2

3.7

PHaSE

1

1

1

volTS

230

230

230

lbS.

wEiGHT

KG

7

8

12

3.2

3.6

5.4

ENcloSUrE

SiZE

B

B

C

60 HZ caTaloG No.

SMC-CRP2021

SMC-CRP3021

SMC-CRP5021

* Submersible Motor Controls are available in single and six packs. Include the suffix ‘-6pk’ after the PN if 6 packs are required.

50 HZ caTaloG No.

SMC5-CRP2021

SMC5-CRP3021

-

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

P 8114 WS

13

14

4" SiNGlE-PHaSE coNTrol boXES

VIP Pro Controls

Capacitor start, capacitor run — designed for the full range of single-phase

1/2, 3/4, 1, 1-1/2, 2, 3 and 5 HP, 3-wire submersible motors

Applications

Water systems…for residential, multiple housing, farm and commercial installations, where a 4" submersible 3-wire motor is used.

Design Features

Enclosure

1

1 Weather resistant construction –

NEMA 3R/IP24 rated enclosure for indoor/outdoor use

2

2 Control box rated for 50 ° C (122 ° F) ambient temperature

3

3 One screw removal for easy panel access with motor running

4

®

proprietary dielectric control panel board, UL and CSA Certified

internals

5

5 Universal controls -designed to work on most manufacturers

3-wire submersible motors

6

6 Large wiring area offers generous space to make your wiring connections.

Incorporates 1/2”, 3/4” and 1” conduit knock-outs

7

offering easier in-the-field troubleshooting

agency approvals

CSA CUS Certified

4

8

2

5

6

3

7

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

1

THE COMPONENT, PART, OR ASSEMBLY DESCRIBED IN THIS DOCUMENT MUST COMPLY WITH THE FOLLOWING EU (EUROPEAN UNION) DIRECTIVE, INCLUDING

.25% MAXIMUM LEAD LEVEL FOR ALL COPPER ALLOYS. ROHS DIRECTIVE 2002.95 EC RESTRICTS THE USE OF LEAD, CADMIUM, MERCURY, CHROMIUM, TBT’S

AND OTHER HAZARDOUS MATERIALS. SEE THE TERMS AND CONDITIONS OF THE CONTRACT (PURCHASE ORDER) FOR MORE INFORMATION.

DL P400-177

1 OF 1

SIZE A

LINE 1 LINE 2 YELLOW RED BLACK

(RUN)

(START)

1 OF 1

.25% MAXIMUM LEAD LEVEL FOR ALL COPPER ALLOYS. ROHS DIRECTIVE 2002.95 EC RESTRICTS THE USE OF LEAD, CADMIUM, MERCURY, CHROMIUM, TBT’S

INSIDE COVER

DL P400-178

1 OF 1

6.81

BOTTOM VIEW

LINE 1 LINE 2 YELLOW RED BLACK

NOTES:

PANEL BOARD ASSEMBLY

1. ASSEMBLED 230 VOLT UNITS TO BE HI-POT TESTED AT 1750 VOLTS

FOR 1 SECOND. UNIT LEAD CURRENT NOT TO EXCEED 5mA.

ASSEMBLED 115 VOLT UNITS TO BE HI-POT TESTED AT 1500 VOLTS

FOR 1 SECOND. UNIT LEAD CURRENT NOT TO EXCEED 5mA.

2. TOLERANCE FOR ALL LABELS:

ANGULAR ±3º

LINEAR ± .05 [1.3]

BOX ASSEMBLY WITH COVER REMOVED

PANEL BOARD ASSEMBLY, BOTTOM VIEW

LINE 1 LINE 2 YELLOW RED BLACK

PANEL BOARD ASSEMBLY

INSIDE COVER

FRONT VIEW

SIZE B

PANEL BOARD ASSEMBLY, BOTTOME VIEW

.25% MAXIMUM LEAD LEVEL FOR ALL COPPER ALLOYS. ROHS DIRECTIVE 2002.95 EC RESTRICTS THE USE OF LEAD, CADMIUM, MERCURY, CHROMIUM, TBT’S

AND OTHER HAZARDOUS MATERIALS. SEE THE TERMS AND CONDITIONS OF THE CONTRACT (PURCHASE ORDER) FOR MORE INFORMATION.

DL P400-178

1 OF 1

(START)

(RUN)

BOTTOM VIEW

NOTES:

1. ASSEMBLED 230 VOLT UNITS TO BE HI-POT TESTED AT 1750 VOLTS

FOR 1 SECOND. UNIT LEAD CURRENT NOT TO EXCEED 5mA.

ASSEMBLED 115 VOLT UNITS TO BE HI-POT TESTED AT 1500 VOLTS

FOR 1 SECOND. UNIT LEAD CURRENT NOT TO EXCEED 5mA.

2. TOLERANCE FOR ALL LABELS:

ANGULAR ±3º

LINEAR ± .05 [1.3]

NOTES:

BOTTOM VIEW

LINE 1 LINE 2 YELLOW RED BLACK

All drawings and specifications as well as processes, materials, compounds and other similar criteria are to be strictly adhered to. No modifications allowed without prior written approval.

CRITICAL FEATURES ARE CIRCLED

B 500000048365

A 500000045918

CHANGE

ORDER

No.

RCC

9/20/2013

RC

4/15/2013

DATE

DO NOT SCALE DRAWING

TOLERANCE EXCEPT AS NOTED

[X.]

.X

[.X]

.XX

[.XX]

.XXX

.030 [.76]

.015 [.38]

.005 [.13]

125 [3.2]

ANGULAR ½

THIRD ANGLE PROJECTION

CONFIDENTIAL contains trade secrets and other proprietary information of Pentair

Water. Duplication, disclosure or use are forbidden without the written consent of

Pentair Water.

DR.

RC

CH.

AP.

HERRING

HENNIG

~

SYMBOL

CONTROL BOX

(ASSEMBLY)

W/O PROTECTOR

DATE:

4/15/2013

SCALE:

1:1

DL P400-177

SHEET:

1 OF 1

2. TOLERANCE FOR ALL LABELS:

ANGULAR ±3º

LINEAR ±.05 [1.3]

FRONT VIEW

8.19

10/1/2013 1:28:38 PM -

INSIDE COVER

BOX ASSEMBLY WITH COVER REMOVED

PANEL BOARD ASSEMBLY, BOTTOME VIEW

VIP Control Box Specification

CATALOG

NUMBER HP

VIP4C02 0.50

KW PHASE VOLTS HERTZ TYPE

0.37

1 230 60

WEIGHT ENCLOSURE

LBS KG

CSCR 4.6 2.1

SIZE

A

PN

U17-1422

START CAPACITOR

RATING

43MFD-270V-15kΩ

PN

RUN CAPACITOR

RATING

U17-1419 15MFD-370V

VOLTAGE

RELAY

U17-1592

PROTECTOR

None

VIP4D02

VIP4E02

0.75

1.00

0.55

0.75

1

1

230

230

60

60

CSCR 4.4 2.0

CSCR 4.4 2.0

A

A

U17-1423

U17-1424

59MFD-270V-15kΩ

86MFD-270V-15kΩ

U17-1292

U17-1292

15MFD-370V

23MFD-370V

U17-1592

U17-1592

None

None

VIP4F02 1.50

1.1

1 230 A U17-1430 105MFD-330V-15kΩ U17-1438 10MFD-370V

VIP4G02 2.00

1.5

1 230 60 CSCR 4.6 2.1

A U17-1430 105MFD-330V-15kΩ U17-1440 10MFD-370V

All drawings and specifications as well as processes, materials, compounds U17-1592 without prior written approval.

DESIGNED IN INCHES

[XXX] DIMENSIONS IN mm

TOLERANCE EXCEPT AS NOTED

VIP4H02

VIP4J02

2.2

1 230

UNIT LEAK CURRENT NOT TO EXCEED 5mA.

5.00

3.7

ANGULAR ±3º

LINEAR ±.05 [1.3]

1 230

60

60

CSCR 5.4 2.4

CSCR 8.2 3.7

B

A U17-1428

U17-1437

208MFD-330V-15kΩ

270MFD-330V-15kΩ

U17-1443 45MFD-370V

U17-1442 2 pcs-40MFD-370V U17-1592

B

Control boxes are designed to be used on Pentair motors with the same HP and Voltage ratings. Do not use on motors with different ratings.

REV.

LETTER

500000048374

ORDER

No.

RCC

9/23/2013

RCC

DATE

[X.]

.X

[.X]

.XX

[.XX]

BET00EE-21

.030 [.76]

.015 [.38]

.005 [.13]

125 [3.2]

ANGULAR ½

THIRD ANGLE PROJECTION

CONFIDENTIAL contains trade secrets and other proprietary information of Pentair

Water. Duplication, disclosure or use are forbidden without the written consent of

Pentair Water.

DR.

RCC

CH.

AP.

HERRING

HENNIG

~

SYMBOL

CONTROL BOX

(ASSEMBLY

1.5 HP - 230 V0LT

WITH PROTECTOR

DATE:

4/16/2013

SHEET:

1 OF 1

SCALE:

1:1

DL P400-178

10/1/2013 1:28:38 PM -

All drawings and specifications as well as processes, materials, compounds and other similar criteria are to be strictly adhered to. No modifications allowed without prior written approval.

CRITICAL FEATURES ARE CIRCLED

B 500000048365

A 500000045918

RCC

9/20/2013

RC

4/15/2013

REV.

LETTER

ORDER

No.

DATE

DO NOT SCALE DRAWING

TOLERANCE EXCEPT AS NOTED

[X.]

.X

[.X]

.XX

.030 [.76]

.015 [.38]

[.XX]

.XXX

.005 [.13]

125 [3.2]

ANGULAR ½

THIRD ANGLE PROJECTION

CONFIDENTIAL contains trade secrets and other proprietary information of Pentair

Water. Duplication, disclosure or use are forbidden without the written consent of

Pentair Water.

~

SYMBOL

DR.

CH.

AP.

RC

HERRING

CONTROL BOX

(ASSEMBLY)

W/O PROTECTOR

DATE:

INSIDE COVER

4/15/2013

SHEET:

1 OF 1

SCALE:

1:1

DL P400-177

B

= RENUMBERED ALL BALLONS.

All drawings and specifications as well as processes, materials, compounds and other similar criteria are to be strictly adhered to. No modifications allowed without prior written approval.

CRITICAL FEATURES ARE CIRCLED

DESIGNED IN INCHES

[XXX] DIMENSIONS IN mm

DO NOT SCALE DRAWING

TOLERANCE EXCEPT AS NOTED

[X.]

.X

.030 [.76]

B 500000048374

A 500000045918

RCC

9/23/2013

RCC

4/16/2013

[.X]

.XX

[.XX]

.XXX

.015 [.38]

.005 [.13]

125 [3.2]

ANGULAR ½

THIRD ANGLE PROJECTION

REV.

LETTER

CHANGE

ORDER

No.

DATE

CONFIDENTIAL contains trade secrets and other proprietary information of Pentair

Water. Duplication, disclosure or use are forbidden without the written consent of

Pentair Water.

DR.

RCC

CH.

AP.

HERRING

~

SYMBOL

CONTROL BOX

(ASSEMBLY

1.5 HP - 230 V0LT

HENNIG

WITH PROTECTOR

DATE:

4/16/2013

SHEET:

1 OF 1

SCALE:

1:1

DL

P400-178

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

15

16

PUMP ProTEcTioN

Single-Phase Protectors

Engineered protection for single-phase motors

1/3 - 15 HP, Single Phase, 50/60 Hz applications

Pentek

®

offers a full range of 1/3 - 15 HP

Protectors for Residential, Commercial,

Multiple Housing and Farm Water System applications where a 4" submersible, 2 and

3-wire motor is used and for above-ground pressure-boost applications.

Applications

Pentek offers 5 models for your application needs based on HP and Motor Type: SPP-111P, 

SPP-111P-3RL, SPP-231P, SPP-233P and SPP-235P.

Protects Pumps From

Dry Well Overvoltage

Rapid Cycling Undervoltage

Overcurrent (Jammed Impeller)

Flow Restriction (Dead Head)

Specifications

Model #

115 VOLT MODELS

SPP-111P SPP-111P-3RL SPP-231P

230 VOLT MODELS

SPP-233P SPP-235P

Insider NEMA 3R Insider NEMA 3R NEMA 3R Enclosure Type

1-Phase

Line Voltage

Load Range

Frequency

115VAC

1/3 - 1/2 HP

50 - 60 Hz

115VAC

1/3 - 1 HP

50 - 60 Hz

230VAC

1/2 - 1 HP

50 - 60 Hz

230VAC 230VAC

1/2 - 3 HP 5 - 15 HP

50 - 60 Hz 50 - 60 Hz

Operating Points

Overload

(% of Cal. Point) 125%

Overvoltage

Reset Point

Undervoltage

Reset Point

132VAC

95VAC

Trip Delay

(Overload) 10 sec.

Trip Delay (Dry Well) 2 sec.

Optional Trip Delay 4 sec.

Restart Delay Time

Over/Under

Voltage Delay 5 sec.

All Other Faults

(Dry Well REC. Timer)

2-225 min.

Output Contact

Rating (SPST)

1 HP

Power Consumption

(max.)

Weight w/o Enclosure

Weight w/Enclosure

Enclosure Size

5 amps

10 oz.

-

2.2" x 2.8"

125%

132VAC

95VAC

10 sec.

2 sec.

4 sec.

5 sec.

2-225 min.

1 HP

5 amps

-

1.6 lbs.

6"x 6"x 4"

125%

265VAC

190VAC

10 sec.

2 sec.

4 sec.

5 sec.

2-225 min.

1 HP 3 HP 480VA @

(17 amps max.) (17 amps max.) 240VAC

5 amps

10 oz.

-

2.2"x 2.8"

125%

265VAC

190VAC

5 sec.

2 sec.

4 sec.

125%

265VAC

190VAC

5 sec.

2 sec.

4 sec.

5 sec. 5 sec.

2-225 min. 2-225 min.

5 amps

14 oz.

5 amps

14 oz.

1.6 lbs. 1.6 lbs.

6"x 6"x 4" 6"x 6"x 4"

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

PUMP ProTEcTioN

“The Insider ” SPP-111P & SPP-231P

For 1/3–1 HP applications

Applications

Water systems…for residential, multiple housing, farm and commercial installations, where a 4" submersible 3-wire motor is used.

SPP-111P & SPP-231P Insiders are “current monitors” designed to protect Single-Phase pumps, which fit inside 1/3 - 1 HP 115V and

230V CSIR control boxes. A simple adjustment allows the Insider to be calibrated to your specific pumping applications, reducing the possibility of false or nuisance tripping. Its unique microprocessor constantly monitors the incoming power for fluctuations in voltage and current. If loss of suction or other abnormality is detected, the

Insider deactivates its output relay and directly disconnects the pump motor. Then it begins its user-selectable “Restart Delay/

Dry Well Recovery” timer. When the timer counts zero or power is removed and reapplied, the Insider reactivates its output relay and turns the pump back on.

The Pentek

®

Informer Remote Handheld Diagnostic Tool (sold separately) communicates directly with all Pentek Pump Protectors and instantly displays 16 parameters including calibration points, running points and last fault (see page 15).

Protects pumps from

Dry Well Overvoltage Flow Restriction (Dead Head)

Undervoltage Overcurrent (Jammed Impeller)

Features

Restart delay can be set up to 225 minutes or placed in manual reset mode

Can be calibrated to specific pump/motor combinations and various conditions

Infrared communication with the Pentek Informer makes diagnostics simple

Fits in existing 3-wire motor control boxes

SPP-231P installed

HP

1/3–1/2

1/3–1

PHaSE

1

1

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK volTS

115

230

FrEQUENcY

50-60 Hz

50-60 Hz

caTaloG

NUMbEr

SPP-111P

SPP-231P

lbS.

1

1

wEiGHT

KG

0.45

0.45

P 8115 WS

17

18

PUMP ProTEcTioN

SPP-111P-3RL, SPP-233P & SPP-235P

For 1/2–15 HP applications

HP

1/2 – 1

1/2 – 1-1/2

1/2 – 3

5 & 7-1/2

10

15

* Current transformer included.

PHase

1

1

1

1

1

1

VOLTs

115

230

230

230

230

230

Applications

Water systems…for residential, multiple housing, farm and commercial installations, where a 4" 2 or 3-wire submersible motor or above-ground motor is used.

Protects Pumps From

Dry Well

Flow Restriction (Dead Head)

Overcurrent (Jammed Impeller)

Features

Overvoltage

Undervoltage

The SPP-111P-3RL, SPP-233P & SPP-235P single-phase protectors include a unique microcontroller-based voltage and current-sensing circuit that constantly monitors the incoming power for fluctuations including overcurrent and undercurrent. When an abnormality, such as loss of suction, is detected, the control deactivates its output relay and directly disconnects the pump motor. The SPP then begins its user-selectable restart delay (dry-well recovery) timer. When the timer counts to zero or power is removed and reapplied, the SPP reactivates its output relay and turns the pump back on. An infrared LED communicates directly with a handheld diagnostic tool called the Informer (sold separately). The Informer displays 16 parameters including calibration point, trip point, running points, and last fault. The SPPs are all mounted in a

NEMA 3R enclosure.

FReQUeNCY

50-60 Hz

50-60 Hz

50-60 Hz

50-60 Hz

50-60 Hz

50-60 Hz

CaTaLOg

NUmbeR

SPP-111P-3RL

SPP-233P-1.5

SPP-233P

SPP-235P-75*

SPP-235P-100*

SPP-235P-150*

Lbs.

1.6

2

2

2

1.6

1.6

WeigHT

Kg

0.7

0.7

0.7

0.9

0.9

0.9

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

PUMP ProTEcTioN

The Informer

Remote handheld diagnostic tool

Applications

The Pentek

®

Informer is a handheld diagnostic tool designed for use with Pentek Single-Phase Pump

Protectors equipped with infrared LED transmitters

(SPP-111P, 231P, 233P & 235P models).

Features

The Pentek Informer uses an infrared receiver to access data sent from the SPP, allowing remote troubleshooting of the system.

Each Pentek SPP is equipped with an infrared LED that transmits information from the device. The Informer must be aimed at the SPP as shown in the figure below.

As soon as power is applied, the Informer begins receiving both past and present information and displays it on the LCD.

The green COMM STATUS light indicates when the

Informer is receiving data from the SPP. If communication is lost, the Informer will hold the last values it received.

Displayed Parameters

diagnostic information received and displayed in real-time:

Voltage, Current, Power, Dry Well

Overload Trip Points

Calibration Voltage

Last Fault

Highest/Lowest Voltage Since Last Calibration

caTaloG

NUMbEr

SPP-Informer

lbS.

1

wEiGHT

KG

0.45

P 8116 WS

19

20

6" SUbMErSiblE MoTorS

6˝ Submersible Motors

For high-thrust water well applications

5-30hp, 230V, 60hz, 3 phase, 5-50hp, 460/380V, 60/50hz, 3 phase

Pentair's line of Pentek

®

motors are designed for long service life and years of dependable operation. Innovative design and robust characteristics make this the perfect motor for your pumping applications.

ENcaPSUlaTEd, waTEr-FillEd dESiGN

The Pentek submersible motor combines internal lubrication (a cooling blend of water, glycol, and propylene), along with superior materials, to provide the industry with innovative and advanced design features that will extend the serviceable life of your installation. The encapsulated design provides superior insulation, heat transfer properties, and stability to the motor’s windings (protecting the windings from “flexing” or “vibration”).

addiTioNal FEaTUrES

Exceptional insulation rating (Class F) and temperature rating (95°F / 35°C)

Vertical or horizontal mounting orientation

VFD-compatible

IP 68 protection rating

Thrust bearing

Water lubricated, Kingsbury-

Type – industry-accepted standard for thrust bearing construction.

Mechanical Seal

Silicone Carbide – excellent abrasion, wear, and corrosion resistance; resists deflection in high-pressure, high heat, and highspeed conditions; high thermal conductivity (heat dissipation).

Provides superior protection against sand intrusion.

Pressure Equalizing diaphragm

Minimizes expansion pressure inside the motor due to changes in temperature and pressure.

Motor lead – 157” / 4m – potted connection, including ground wire.

Non-jacketed wire assembly for easier handling and connections.

Fully replaceable.

Shaft – standard NEMA-splined,

431 stainless steel; excellent tensile and torque strength, and corrosion resistance

External sand slinger – added protection against sand and other abrasives

Upper bracket – “dual-flange”style; easier and faster assembly to the pump

Upper bracket – epoxy-coated cast iron; applied via electrodesposition – provides better adhesion of the coating and more consistent coverage, delivering a longer lasting, more durable coating

Motor casing – 304 stainless steel; excellent forming and welding characteristics, and corrosion resistance

lower bracket – epoxy-coated cast iron; applied via electrodesposition – provides better adhesion of the coating and more consistent coverage, delivering a longer lasting, more durable coating

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

Materials of Consturction

ParTS

Motor sleeve, fasteners

Castings

Shaft

Thrust bearings

Mechanical seal

Diaphragm, sand slinger

MaTErialS

304 stainless steel cast iron - epoxy coated (applied via electrodesposition)

NEMA splined, 431 stainless steel

Kingsbury-type disc - carbon (resin impregnated) pad - 420 stainless steel silicon carbide nitrile rubber

6" SUbMErSiblE MoTorS

Motor Dimensions

L

PENTEK 6" encapsulated - motor data sheet

Nominal diameter

Effective diameter

Shaft extension length

6"/152.4 mm

5.43"/138 mm

2.87" / 73 mm

MOTOR

TYPE PHASE NOTE

PENTEK

MODEL #

6PM2-5-2

HP KW HZ VOLTS

5 3.7

6PM2-7-2 7-1/2 5.5

6PM2-5-2-01 5 3.7

AMPS

RATED

EFF.

15.8 77 78

SERVICE FACTOR 1.15 LOCKED

% P.F. % AMPS

EFF.

% P.F. %

17.4 77 81

ROTOR

AMPS

97.5

KVA

CODE

J

22.0 79

15.8 77

82

78

24.4 79

17.4 77

84

81

147.9

97.5

J

J

THRUST

LOAD

(LBS)

1763

INSULATION

CLASS

WINDING

RESISTANCE

(OHM)

0.79

0.54

0.79

Motors are 60 Hz only

6PM2-7-2-01 7-1/2 5.5

6PM2-10-2 10 7.5

6PM2-15-2

6MP2-20-2

6PM2-25-2

15 11.0

20 15.0

25 18.5

60 230

22.0 79

30.8 77

43.2 78

57.4 79

69.0 81

82

81

84

85

86

24.4 79

33.0 78

47.0 78

63.0 79

76.0 80

84

83

86

87

88

147.9

187.6

281.8

394.5

480.2

J

J

J

J

J

3485

6PM2-30-2

6PM2-5-4

30 22.0

5 3.7

6PM2-7-4 7-1/2 5.5

50

60

50

60

50

380

460

380

460

380

76.6 84

9.1

7.9

76

77

12.8 78

11.0 79

9.1 76

88

84

78

86

82

84

85.0 84

8.7 77

12.2 79

89

81

84

614.2

45.5

48.8

67.9

74.0

45.5

G

G

G

J

K

J

1763

0.14

2.97

1.98

6” Three

6PM2-5-4-01 5 3.7

6PM2-7-4-01 7-1/2 5.5

60

50

460

380

460

380

460

7.9 77

12.8 78

11.0 79

17.8 78

15.4 77

78

86

82

85

81

8.7 77

12.2 79

81

84

48.8

67.9

74.0

85.6

93.8

G

G

J

J

J

F

2.97

1.98

Motors are dual rated

50 Hz &

60 Hz

6PM2-10-4

6PM2-15-4

6PM2-20-4

6MP2-25-4

10 7.5

15 11.0

20 15.0

25 18.5

60

50

60

50

60

50

60

50

60

380

460

380

460

380

460

25.6 77

21.6 78

34.0 78

28.5 79

41.0 79

34.5 81

87

84

89

85

89

86

16.5 78

23.5 78

31.5 79

38.0 80

83

86

87

88

127.0

140.9

170.2

197.3

219

240.1

G

G

J

F

J

J

3485

1.46

0.99

0.72

0.56

6PM2-30-4 30 22.0

50

60

380

460

46.0 83

38.0 84

90

88 42.5 84 89

276.8

307.1

G

J

0.50

6PM2-40-4

6PM2-50-4

40 30

50 37

50

60

50

380

460

380

62.5 83

52.7 84

77.6 83

90

88

90

58.0 84 89

393.1

439.7

449.8

G

H

K

6182

0.40

0.33

60 460 64.3 85 87 70.8 85 89 500.5

J

* = Motors with serial numbers beginning with 200, and serial numbers between 20105213xxxx and 20109113xxxx, are equipped with a 4-stud, “single-flange”-style mounting bracket.

** = Motors with serial numbers beginning with 20109213xxxx are equipped with a “dual-flange”-style mounting bracket.

50 Hz performance numbers are at a service factor of 1.0.

0.54

0.40

0.28

0.21

0.16

LENGTH WEIGHT

RPM IN* MM* IN** MM** LBS

3445 22.7 577 21.1 535 90

3450 24.9 632 22.7 577 102

3445 22.7 577 21.1 535 90

3450

2820

3450

2880

3500

2860

3450

2800

3440

2810

3450

2810

2810

3450

2800

3445

2810

3450 24.9 632 22.7 577 102

3440 29.2 741.5 24.9 632 116

3450 31.8 807.5 27.5 698 121

3450 35.1 892.5 35.1 892.5 147

3450 38.0 964.5 38.0 964.5 165

3500 41.8 1,060.5 41.1 1,044.5 190

2800

3445

22.7

577 21.1

535 90

24.9

22.7

24.9

632

577

632

22.7

21.1

22.7

577

535

577

102

90

102

29.2 741.5 24.9

31.8 807.5 27.5

632

698

116

131

35.1 892.5 35.1 892.5 147

38.0 964.5 38.0 964.5 165

41.8 1060.5 41.1 1044.5 190

47.1 1197 44.7 1134.5 209

3490

2840

3480

49.9 1267 47.4 1204.5 292

55

67

75

46

53

86

46

41

KG

41

41

46

41

46

53

55

67

75

86

95

132

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

21

6" SUbMErSiblE MoTorS

6" Hitachi

®

Submersible Motors

For high-thrust water well applications

5-50 HP, Single and Three Phase, 200V, 230V and 460V, 60 Hz, 3,600 RPM

Hitachi

®

Motors are designed for long service life and years of dependable operation. Innovative design and robust characteristics make this the perfect motor for your pumping applications.

Encapsulated, Water-Filled Design

Combined with exceptional insulation and a patented epoxy fill resin, these motors exceed NEMA requirements for high water temperature by 18°F (-7.7°C). Designed with internal lubrication and cooling blend of water, antifreeze, and an antirust mixture, Hitachi submersible motors are unique in providing the industry with innovative and robust design features that will extend the serviceable life of your installation.

Features

Higher Efficiencies and Lower Current Consumption –

For reduced energy costs

Corrosion-Resistant Design – For long life

High-Capacity Kingsbury-type Bearings – 

For dependable performance

Low-Profile NEMA Design – For ease of installation

Replaceable Plug-in Motor Lead – For ease of maintenance

Dual Voltage Type – For application versatility

(5 HP – 30 HP 3-Phase Motors)

VFD-Compatible

Hitachi

®

is a registered trademark of Hitachi Industrial Equipment

Systems Co., Ltd.

22

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

Materials Of Construction

Motor Dimensions

ParTS MaTErialS

Motor Sleeve Stainless steel construction

Castings

Fasteners

Shaft

Flange

Baked epoxy-coated gray iron

Stainless steel

NEMA splined stainless steel

NEMA standard type

Rotor

Thrust Bearings

Mechanical Seal

Diaphragm

Double epoxy-coated

Kingsbury-type 420 stainless steel

Nitrile rubber (NBR), grease packed

Nitrile rubber

Sand Cap

Sand Slinger

Lead Wire (or Cable)

Polyurethane

Stainless steel

Double-insulated, heat and water-resistant,

167°F/75°C, 600V

D

6" SUbMErSiblE MoTorS

L1

L

DIAMETER HP KW VOLTS PH HZ

6 5 3.7

200 3 60

6

6

6

6

6

6

6

6

6

6

6

6

6 5

5

5

7.5

7.5

7.5

7.5

10

10

10

10

15

15

3.7

3.7

3.7

5.5

5.5

5.5

5.5

7.5

7.5

7.5

7.5

11

11

230

230

460

200

230

230

460

200

230

230

460

200

230

3

3

3

3

3

3

3

3

3

1

1

1

1 60

60

60

60

60

60

60

60

60

60

60

60

60

CATALOG

NUMBER

6HIT2-5-8

6HIT2-5-1

6HIT2-5-2

6HIT2-5-4

6HIT2-7-8

6HIT2-7-1

6HIT2-7-2

6HIT2-7-4

6HIT2-10-8

6HIT2-10-1

6HIT2-10-2

6HIT2-10-4

6HIT2-15-8

6HIT2-15-1

SERVICE

FACTOR

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

40

50

60

30

30

25

30

20

25

25

15

15

20

20

8

6

8

6

6

6

6

6

6

6

6

6

6

6

30

37

45

18.5

22

22

22

15

18.5

18.5

11

11

15

15

3

3

3

3

3

3

3

3

3

3

3

3

3

3

460

460

460

460

200

230

460

460

200

230

230

460

200

230

60

60

60

60

60

60

60

6HIT2-15-2

6HIT2-15-4

6HIT2-20-8

6HIT2-20-2

6HIT2-20-4

6HIT2-25-8

6HIT2-25-2

60

60

60

60

6HIT2-25-4

6HIT2-30-8

6HIT2-30-2

6HIT2-30-4

60 6HIT2-40-4

60 86HIT2-50-4*

60 86HIT2-60-4*

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

*Models are 8" motors with 6" pump connection.

Hitachi

®

Control Boxes:

WINDING

RESISTANCE

(OHMS)

0.618

R-Y, B-Y, R-B, 2.172,

0.512, 2.627

0.806

3.05

0.504

R-Y, B-Y, R-B, 1.401,

0.400, 1.774

0.651

2.43

0.315

R-Y, B-Y, R-B, 1.052,

0.316, 1.310

0.448

1.619

0.213

R-Y, B-Y, R-B, 0.678,

0.230, 0.850

0.312

1.074

0.189

0.258

0.861

0.146

0.21

0.666

0.119

0.166

0.554

0.358

0.331

0.278

Type 1 NEMA Enclosure

In-Panel Circuit Breaker

Magnetic Contactor

Terminal Blocks for External Controls

UL Recognized

RATED

INPUT

AMPS

17.5

24

15

7.5

25.4

36

22

11

33.3

50

29

14.5

47.4

72

56

65

80

34

91.8

82

41

42

21

61.2

54

27

77.3

68

SERVICE

FACTOR

INPUT AMPS

19.5

58

33

16.5

53.5

85

61

73

90

38

104

94

47

46

23

69.5

60

30

87.5

76

27.5

17

8.5

28.5

41

26

13

37.2

HP

5

7.5

10

15

Hitachi

®

is a registered trademark of Hitachi Industrial Equipment Systems Co., Ltd.

LOCKED

ROTOR

AMPS

124

202

208

104

347

275

420

435

556

265

674

610

305

196

578

530

320

160

431

392

124

110

55

158

167

144

72

236

Kw

3.7

5.5

7.5

11

LENGTH

(L2)

22.95"

29.92"

26.97"

26.97"

29.92"

33.46"

36.22"

38.19"

39.19"

38.19"

40.55"

45.28"

48.03"

29.92"

29.92"

31.5"

31.5"

31.5"

36.22"

36.22"

26.97"

22.95"

22.95"

24.80"

29.92"

24.80"

24.80"

26.97"

SHAFT

EXTENSION

(L1)

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

2.87"

THRUST

CAPACITY WEIGHT

3,500 95

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

5,000

5,000

5,000

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

3,500

128

110

110

128

148

187

353

408

161

176

176

176

137

161

161

128

128

137

137

110

95

95

99

128

99

99

110

DIAMETER

(D)

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

7.52"

7.52"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

5.5"

PH

1

1

1

1

volTS

230

230

230

230

caTaloG NUMbEr

HIT-5CBD

HIT-7.5CBD

HIT-10CBD

HIT-15CBD

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

P 8174 WS

23

8-14" SUbMErSiblE MoTorS

8"-14" Hitachi

®

Submersible Motors

For high-thrust water well applications

7.5-300 HP, Three Phase, 460V, 60 Hz, 2-Pole, 3,600 RPM. 4-Pole, 1800 RPM

Hitachi

®

Motors are designed for long service life and years of dependable operation.

Innovative design and robust characteristics make this the perfect motor for your pumping applications.

Rewindable, water-tight Design

Specially developed leak-resistant denatured polypropylene completely protects the copper coil conductors from internal cooling fluids for long service life in severe operating condidtions. Hitachi submersible motors are unique in providing the industry with innovative and robust design features that will extend the serviceable life of your installation.

Features

Higher Efficiencies and Lower Current Consumption –

For reduced energy costs

Corrosion-Resistant Design – For long life

High-Capacity Kingsbury-type Bearings – 

For dependable performance

Low-Profile NEMA Design – For ease of installation

VFD-Compatible

Hitachi

®

is a registered trademark of Hitachi Industrial Equipment

Systems Co., Ltd.

24

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

8-14" SUbMErSiblE MoTorS

8"-14" Hitachi

®

Submersible Motors

For high-thrust water well applications

Motor Dimensions

Materials Of Construction

L1

ParTS MaTErialS

Housing Baked epoxy-coated gray iron

Fasteners

Shaft

Rotor

Thrust Bearings

Stainless steel

Splined or keyed stainless steel

Double epoxy-coated

Kingsbury

®

-type 420 stainless steel

Mechanical Seal

Diaphragm

Sand Slinger

Lead Wire (or Cable)

Nitrile rubber (NBR), grease packed

Nitrile rubber

Baked epoxy-coated gray iron

Double-insulated, heat and water- resistant, 167°F/75°C, 600V

L

D

DIAMETER HP

10

10

8

10

8

8

8

8

8

8

8

8

8

8

8

8

12

12

10

12

14

14

10

10

10

10

KW VOLTS PH HZ

60

75

40

50

100

125

75

90

200 150

250 185

45

55

30

37

150 110

200 150

300 225

250 185

300 225

7.5

10

15

20

25 18.5

30 22

30

5.5

7.5

11

15

60

75

40

50

100

125 90

150 110

55

75

37

45

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

460

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

3 60

CATALOG

NUMBER

8HIT4-7-4

8HIT4-10-4

8HIT4-15-4

8HIT4-20-4

8HIT4-25-4

8HIT4-30-4

8HIT2-40-4

8HIT2-50-4

8HIT2-60-4

8HIT2-75-4

8HIT2-100-4

8HIT2-125-4

8HIT2-150-4

10HIT4-40-4

10HIT4-50-4

10HIT4-60-4

10HIT4-75-4

10HIT4-100-4

10HIT4-125-4

10HIT2-200-4

10HIT2-250-4

12HIT4-150-4

12HIT4-200-4

12HIT2-300-4

14HIT4-250-4

14HIT4-330-4

WINDING

RESISTANCE

(OHMS)

0.278

0.218

0.164

0.132

0.115

0.408

0.408

0.288

2.178

2.178

1.519

1.519

0.888

0.888

0.372

0.331

0.257

0.171

0.171

0.0929

0.0776

0.138

0.119

0.0386

0.0552

0.0517

SERVICE

FACTOR

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

1.15

SERVICE

FACTOR

INPUT AMPS

220

71

83

104

90

109

145

180

63

73

43

50

26

33

14

18

340

218

250

396

121

166

200

270

350

425

RATED

INPUT

AMPS

197

62

73

91

80

96

127

161

56

65

38

44

23

29

13

16

295

190

220

350

106

145

175

235

305

370

LENGTH

(L2)

49.19

53.15

58.27

66.14

70.08

49.21

49.21

59.84

37.40

37.40

41.34

41.34

44.09

44.09

44.09

46.44

59.84

69.68

69.68

69.68

79.53

56.3

68.11

78.75

68.31

76.18

SHAFT

EXTENSION

(L1)

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

4.000

5.000

5.000

5.000

5.000

5.000

5.000

5.000

5.000

5.000

LOCKED

ROTOR

AMPS

1331

286

286

474

556

675

855

1122

207

207

380

435

98

98

151

151

1500

1021

1195

2700

485

670

693

1260

1870

2300

THRUST

CAPACITY

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

10000

DIAMETER

(D)

7.52

8.52

8.52

8.52

7.52

7.52

7.52

7.52

7.52

7.52

7.52

7.52

7.52

7.52

7.52

7.52

8.52

10.53

10.53

10.53

8.52

8.52

8.52

8.52

12.60

12.60

*Motor is 8" diameter, but constructed to operate with a 6" liquid end.

** 8" motors with 6" flange when using stainless steel bolts have a thrust rating of 5,000 lbs.

A thrust value of 10,000 lbs. can be obtained using grade-8 heat-treated stainless steel bolts.

Hitachi

®

is a registered trademark of Hitachi Industrial Equipment Systems Co., Ltd.

WEIGHT

661

507

507

639

408

463

518

595

342

342

320

353

298

298

320

320

1455

959

1235

1455

639

794

794

948

1698

1940

P 8174 WS

25

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

26

THrEE-PHaSE STarTErS

PPX NEMA Pump Panels

NEMA Certified, heavy-duty design for outdoor applications

NEMA Pump Panels, Size 1 – 5, 208V, 230 – 240V, 460 – 480V, 575 – 600V

Pentek

®

PPX Pump Panels are designed for agricultural and commercial above-ground pumping applications and provide full-voltage control of AC motors up to

200 HP. PPX panels are offered in NEMA 3R (outdoor rated) enclosures with a door gasket to protect electrical components from harsh environments.

Features

NEMA 3R (Outdoor Rated) Enclosure

Class R Fusible Disconnect (fuses not included)

NEMA rated components

Electronic overloads with user-selectable current ranges, trip characteristic and manual/ automatic restart

External Overload Reset

Split mounting plate design enables easy mounting of devices without disconnecting the main motor circuit

Mounting Configuration

ON

50°

OFF

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

THrEE-PHaSE STarTErS

PPX Selection Guide

208 VAC

NEMA SIZE

1

2

3

4

2

3

MAX HP OF

CONTACTOR

7.5

10

25

40

230-240 VAC

NEMA SIZE

MAX HP OF

CONTACTOR

1 7.5

15

30

DISCONNECT A

30

60

100

200

DISCONNECT A

30

60

100

MAX TOTAL A

OF PPX PANEL

13.5

27

50

70

100

135

MAX TOTAL A

OF PPX PANEL

13.5

27

50

70

100

OIL CURRENT

RANGE

6.5 – 13.5

13 – 27

25 – 50

35 – 70

CATALOG

NUMBER

PPX-1A-13-30R

PPX-1A-27-30R

PPX-2A-50-60R

PPX-3A-70-100R

DIMENSIONS

H x W x D

34 x 21 x 7

34 x 21 x 7

34 x 21 x 7

47.5 x 25 x 9

WEIGHT

(LBS.)

85

85

90

195

65 – 135

65 – 135

PPX-3A-135-100R

PPX-4A-135-200R

47.5 x 25 x 9

47.5 x 25 x 9

195

195

Note: For HPs with multiple part numbers, use motor amperage to select a panel.

OIL CURRENT

RANGE

6.5 – 13.5

13 – 27

25 – 50

35 – 70

65 – 135

CATALOG

NUMBER

PPX-1B-13-30R

PPX-1B-27-30R

PPX-2B-50-60R

PPX-3B-70-100R

PPX-3B-135-100R

DIMENSIONS

H x W x D

34 x 21 x 7

34 x 21 x 7

34 x 21 x 7

47.5 x 25 x 9

47.5 x 25 x 9

WEIGHT

(LBS.)

85

85

90

195

195

Note: For HPs with multiple part numbers, use motor amperage to select a panel.

460-480 VAC

NEMA SIZE

MAX HP OF

CONTACTOR

1

2

3

4

5

10

25

50

100

200

DISCONNECT A

30

60

100

200

400

MAX TOTAL A

OF PPX PANEL

13.5

27

50

70

100

135

270

OIL CURRENT

RANGE

6.5 – 13.5

13 – 27

25 – 50

35 – 70

65 – 135

65 – 135

130 – 270

CATALOG

NUMBER

PPX-1C-13-30R

PPX-1C-27-30R

PPX-2C-50-60R

PPX-3C-70-100R

PPX-3C-135-200R

PPX-4C-135-200R

PPX-5C-270-400R

DIMENSIONS

H x W x D

34 x 21 x 7

34 x 21 x 7

34 x 21 x 7

47.5 x 25 x 9

47.5 x 25 x 9

47.5 x 25 x 9

52 x 22 x 10

WEIGHT

(LBS.)

85

85

90

195

195

195

285

Note: For HPs with multiple part numbers, use motor amperage to select a panel.

575-600 VAC

NEMA SIZE

1

2

3

4

5

MAX HP OF

CONTACTOR

10

25

50

100

200

DISCONNECT A

30

60

100

200

400

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

MAX TOTAL A

OF PPX PANEL

13.5

27

50

70

100

135

270

OIL CURRENT

RANGE

6.5 – 13.5

13 – 27

25 – 50

35 – 70

65 – 135

65 – 135

130 – 270

CATALOG

NUMBER

PPX-1D-13-30R

PPX-1D-27-30R

PPX-2D-50-60R

PPX-3D-70-100R

PPX-3D-135-100R

PPX-4D-135-200R

PPX-5D-270-400R

DIMENSIONS

H x W x D

34 x 21 x 7

34 x 21 x 7

34 x 21 x 7

47.5 x 25 x 9

47.5 x 25 x 9

47.5 x 25 x 9

52 x 22 x 10

WEIGHT

(LBS.)

85

85

90

195

195

195

285

Note: For HPs with multiple part numbers, use motor amperage to select a panel.

P 8175 WS

28 drivE ProdUcTS

PENTEK

INTELLIDRIVE

WATER PRESSURE CONTROL CENTER

coNSTaNT PrESSUrE

For wEll PUMP SYSTEMS

For use with both Submersible and above Ground well Pumps to control changes in water demand

Most homeowners with well systems know what happens when demand for water changes. If they’re taking a shower, water pressure drops when someone starts the dishwasher or turns on a faucet. Weak showers, unclean dishes and other water pressure problems become frustrating daily experiences.

a “variable Frequency drive” for Submersible or above Ground well Pumps.

The Pentek Intellidrive

Water Pressure Control

Center directs changes in pump motor speed, responding to fluctuations in demand. If water pressure starts dropping, an electronic pressure transducer signals the drive to accelerate the pump motor to increase water volume going into the home.

The benefit? Strong, equal pressure, everywhere.

Homeowners will recognize the difference right away.

Water flows smoothly and evenly throughout the home.

Regardless of changes in demand, water pressure stays the same: in the shower, the dishwasher, and from every other faucet and fixture.

And when homeowners are outside, they’ll enjoy a lush, green lawn and landscaping. Sprinkler systems will perform at their best, with consistent spray patterns, constantly pressurized to achieve complete coverage.

The pump and motor will last longer.

Pentek Intellidrive

features “Soft Start/Coast to Stop” design, which minimizes mechanical stress. And during long-running applications like lawn irrigation, pressurecycling is eliminated…another system stress reducer.

Pentek Intellidrive Leading-edge technology for a premium residential water system that makes life better!

ADVANCED TECHNOLOGY. SUPERIOR PERFORMANCE.

drivE ProdUcTS

KEYHolE MoUNT

For fast and easy installation lcd iNForMaTioN cENTEr

Displays installation,

status and fault information in easy-tounderstand language instead of codes

GroUNd dETEcTioN

Message Center shows if there is a grounding problem

MUlTiPlE accESSorY iNPUTS

Additional inputs allow use of multiple drive accessories at the same time

bEST-iN-claSS

EMi/rFi FilTEr

Superior noise and

interference protection,

including AM radio signals

SPacioUS wiriNG arEa

For fast and easy

installation

ProGraMMablE iNPUT/oUTPUT rElaYS

Provide application

flexibility

EaSY-accESS coNdUiT oPENiNGS

Align with appropriate terminals for straight-in accessibility. Fits 1/2", 3/4" or 1-1/4"

ElEcTroNic

PrESSUrE TraNSdUcEr

More accurate and reliable

than mechanical pressure

switch, with piezo resistive

technology designed to

resist water hammer

TEMPEraTUrE-

SENSiTivE

iNTElliGENT FaN

Operates when needed for quiet operation

Sd card SloT

For easy software updates when provided

by manufacturer

SPriNG TErMiNalS

For secure connections

and easy installation

without special tools

rEMovablE

TErMiNal blocKS

For easy wiring of motor

and power supply – field replaceable

29

drivE ProdUcTS

AN INTELLIGENT CONTROL...

SIMPLE TO OPERATE,

EASY TO UNDERSTAND.

No other variable frequency drive provides such an effective operator interface

with easy touchpad operation and a spectrum of features that allows easy configuration for most residential water control applications. And the

LCD Information Center communicates clearly in words, instead of confusing light codes.

STarT-UP iS SiMPlE…

ENTER MOTOR PHASE ENTER MOTOR TYPE ENTER SERVICE FACTOR AMPS ENTER CURRENT TIME ENTER CURRENT DATE

30

1 bacKliT lcd diSPlaY

PUMP-oUT bUTToN

For cleaning of new wells and fixed frequency operation

PSi PrESET

Sets pressure to any value desired

lEd STaTUS iNdicaTioN

2 3 4

6

5

CHOOSE “PUMP OUT”

OR “AUTO START”

diaGNoSTicS iNdicaTor

Self diagnostic messaging for ease of service

FaUlT loG

Stores 15 faults with timestamps

KEYPad locKoUT

For security against tampering and unintended adjustments

MUlTi-liNGUal oPTioNS

English, French or Spanish

aUTo-STarT

With automatic line-fill functionality, providing constant pressure operation

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

ModEl NUMbEr

PID10

PID20

PID50

MoTor TYPE

1-PHASE

2-WIRE*

1-PHASE

3-WIRE

3-PHASE

1-PHASE

2-WIRE*

1-PHASE

3-WIRE

3-PHASE

1-PHASE

2-WIRE*

1-PHASE

3-WIRE

3-PHASE

*Pentek

®

(PSC) 2-wire motors only

1.5

2.0

2.0

1.5

2.0

5.0

drivE ProdUcTS

Product Line Overview

MaXiMUM HP

1.0

iNPUT volTaGE

190-265

oUTPUT aMPS

9.5

ENcloSUrE raTiNG

3R

1.0

1.0

190-265

190-265

7.5

5.0

3R

3R

190-265

190-265

190-265

190-265

190-265

190-265

11.0

13.5

8.5

11.0

13.5

18.0

3R

3R

3R

3R

3R

3R p pump motor.

31

PENTEK iNTEllidrivE

accESSoriES

VFD-ALT

Alternating Control Panel for the PENTEK INTELLIDRIVE

The Alternating Panel is designed to equalize wear on the pumps by alternating two Pentek Intellidrive

VFD’s every

24 hours. This panel alternates which pump is the lead and lag in a duplex system. It can also be used independently of the lead/lag function.

Applications

Alternate Pentek Intellidrive VFD's on pressure boosting systems. Equalize wear on pumps.

Power On Indicator

Pump 1 Enabled Indicator

Pump 2 Enabled Indicator

Alternate/Off Switch

Specifications

120 VAC

6 ft. Power Cord

NEMA 1 Enclosure

4 Terminal Blocks To Connect VFD's - Use 18 AWG Wire

The Alternating Pentek Intellidrive

Control Panel will alternate pumps that are connected to the Pentek Intellidrive.

* Additional programming is necessary in the Pentek Intellidrive.

System Overview

After the panel is mounted, wire the panel, plug it into a 120 VAC outlet, and turn the switch to Alternate.

“Pump 1” will turn on and the “pump 1 enable” LED will illuminate. After 24 hours “Pump 2” will turn on and the “pump 2 enable” LED will illuminate.

32 model

Number

VFD-ALT

rated volts

120 VAC

HZ

50/60

HeigHt

5.375

dimeNsioNs (iN.) widtH

3.25

deptH

1.625

weigHt lbs.

1.0

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

PENTEK iNTEllidrivE

accESSoriES

Surge Protection Kits

120/240 VAC Protection for PENTEK INTELLIDRIVE

Surge protection device for use with any 230V Pentek Intellidrive

. Line side arrester easily installed in the circuit breaker. Load side installed on the drive output. LED

Diagnostic lights help provide positive indication of power and surge protection.*

Features

Compact size to fit most applications

Diagnostic LEDs to indicate system power & surge protection

Weatherproof design allows for use in most environments

VFD-SGA: Surge Protection Kit (includes line & load side)

VFD-SGA-LN: Line Side Surge Protection

VFD-SGA-LD: Load Side Surge Protection

Service Voltage: 240 VAC (line side); 240VAC (Load side)

Parallel connection for easy installation

Load Side:

Auto reset to handle multiple surges

Service Wiring

Peak Surge current

McOv

Line Side:

Two Power Cords +

Ground

75,000A 320V

Service Wiring

Two Power Cords

+ Ground

Peak Surge current

72,000A/Phase

36,000A/Mode

McOv

130/260V

uL 1449, 3rd ed, v.P.r.

500V L-G, 900V L-L

ShOrt circuit rating

10,000A

uL 1449, 3rd ed. in v.P.r.

10,000A

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

33

34

PENTEK iNTEllidrivE

accESSoriES

VFD-WS

Moisture Sensor

The Moisture Sensor is designed to shut off your

Pentek Intellidrive

if water is detected. When water touches the two detection points on the bottom of the

Moisture Sensor, it sends a signal to the VFD to shut it off.

Applications

Prevent flooding from broken pipes or leaks! The

VFD-WS is designed to connect to, and shut off, the

Pentek Intellidrive when water from broken pipes is detected. The entire property you are providing water to is protected from flooding.

Detects water At 1/16"

Waterproof epoxy encapsulated enclosure

Indicators for alarm condition and ready condition

Auto reset

Specifications

24 VDC

Detects water at 1/16"

Auto reset

Red alarm indicator for a water alarm

Green ready indicator to indicate the systems is ready for operation

4 Conductor 18 gauge cable

15 Foot cord length

Pentek

®

Moisture Sensors detect water and shut down your Pentek Intellidrive in the event of a water leak.

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

PENTEK iNTEllidrivE

accESSoriES

Model Number & System Overview

ModEl

NUMbEr

VFD-WS

raTEd volTS

24VDC

HZ

N/A

HEiGHT

1.075

diMENSioNS (iN.) widTH

3.0

dEPTH

1.5

wEiGHT lbS.

1.0

System Overview

(Fig. 1 - When the sensor is dry and the system has power, the green “Ready” indicator will be illuminated.) (Fig. 2 - The red “Alarm” indicator light will illuminate if water is touching both detection points on the bottom of the

Moisture Sensor.) The Moisture Sensor can be automatically reset by wiping of the sensors on the bottom of the unit. (Fig. 3 - When the Moisture Sensor is dry, the green “Ready” indicator will illuminate.) The Pentek Intellidrive

must be

"Reset" to return to normal operation.

Fig. 1

Green "Ready"

Indicator

Illuminated

Fig. 2

Red “Alarm” Indicator is illuminated if water is touching the two detection points on the bottom of the Moisture Sensor.

Fig. 3

Green "Ready"

Indicator Illuminated

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

35

drivE ProdUcTS

PPC3 & PPC5

State-of-the-art pump protection and controllers

Pentek

®

Pump Controllers provide innovative pumping solutions for maximizing pump functionality, optimizing pump system design and reducing operating energy costs.

Pentek PPCs can be used on all centrifugal motor-driven pumps including close-coupled motor drive, frame mount, submersible and line shaft turbine pumps, in a wide range of applications.

36

PPC5 NEMA 1

*NEMA 1 Enclosure meant for Indoor Use

PPC3 NEMA 1

PPC5 NEMA 1

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

drivE ProdUcTS

PPC Features

The Pentek

®

PPC3 and PPC5 Pump Controllers are programmed with the Pentek Assistant and pre-jumpered, providing ease of setup for constant pressure applications. The Pentek Assistant defaults to pre-defined parameters and prompts the user for application-specific information. The ‘Help’ key activates parameter descriptions, providing easy reference to the programming guide.

Pentek assistant

Guides the user through the setup process for constant pressure applications, taking less than 2 minutes to program; allows for local or remote operation

Includes macros for both submersible and above-ground pump applications

System harmonics evaluation process

additional application Functions

Auto-Restart Functionality – re-starts pump after power loss

Easily configured for constant flow applications by adjusting 2 additional menu parameters

Multiple System Setpoints or Operating Condition – includes 2 independent process control setpoints to allow operation under a second process

Time Function supports 4 Daily and Weekly

START/STOP/BOOST times

Process Benefits

variable Speed control

Meets requirements of process control with constant pressure at variable flow conditions or constant flow at variable pressure conditions

reduced Energy costs

Calculate energy savings online using BEC2 software at www.bec2.net

Pump Protection

From loss of prime, dead head and blocked suction

Motor Protection

From ground fault, short circuit, phase loss and imbalance, overload, undervoltage and overvoltage

System Protection (PPc5 only)

From harmonics, featuring an input choke that exceeds the performance of a fixed 5% impedance line reactor

Phase conversion

The PPC5 will convert 1-phase power into 3-phase power, allowing the use of a 3-phase motor

The PPC3 is available in both 1 & 3 phase models

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

P 8118 WS

37

38 drivE ProdUcTS

PPC Selection Guide

PPC3, PPC5

PPC3 / PPC5 Comparison

Features

HP Ratings

Voltages

Frequency

Floating Choke

Harmonic Signature

No. of Relays

Digital Inputs

Multiple Pump Capable

Mod. Bus

Enclosure Type

PPC3

1 – 30

230, 460

50/60 Hz

No

Good

1

5

No

No

NEMA 1

PPC5

1/2 – 200

230, 460, 575

50/60 Hz

Yes

Best

3 (ext. to 6 available)

6

Yes

Yes

NEMA 1, 12

The output current (or amps) of the PPC must be greater than or equal to the maximum rated motor current.

PPC3 Selection

200-240 Volt – 1-Phase IN, 3-Phase OUT

OUTPUT

AMPS

4.7

6.7

7.5

9.8

EnclOSUrE

SizE

R1

R1

R2

R2

MOUnTing

WALL

WALL

WALL

WALL

MOdEl nUMbEr nEMA 1

PPC3-1-4A7-1

PPC3-1-6A7-1

PPC3-1-7A5-1

PPC3-1-9A8-1

200-240 Volt – 3-Phase IN, 3-Phase OUT

OUTPUT

AMPS

17.6

24.4

31.0

46.2

4.7

6.7

7.5

9.8

EnclOSUrE

SizE

R2

R3

R4

R4

R1

R1

R1

R2

MOUnTing

WALL

WALL

WALL

WALL

WALL

WALL

WALL

WALL

MOdEl nUMbEr nEMA 1

PPC3-2-4A7-1

PPC3-2-6A7-1

PPC3-2-7A5-1

PPC3-2-9A8-1

PPC3-2-17A6-1

PPC3-2-24A4-1

PPC3-2-31A0-1

PPC3-2-46A2-1

380-480 Volt – 3-Phase IN, 3-Phase OUT

OUTPUT AMPS

8.8

12.5

15.6

23.1

31.0

38.0

44.0

2.4

3.3

4.1

5.6

EnclOSUrE SizE

R1

R3

R3

R3

R4

R4

R4

R1

R1

R1

R1

MOUnTing

WALL

WALL

WALL

WALL

WALL

WALL

WALL

WALL

WALL

WALL

WALL

MOdEl nUMbEr nEMA 1

PPC3-4-2A4-1

PPC3-4-3A3-1

PPC3-4-4A1-1

PPC3-4-5A6-1

PPC3-4-8A8-1

PPC3-4-12A5-1

PPC3-4-15A6-1

PPC3-4-23A1-1

PPC3-4-31A0-1

PPC3-4-38A0-1

PPC3-4-44A0-1

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

OUTPUT

AMPS

17.6

24.4

31.0

46.2

4.7

6.7

7.5

9.8

EnclOSUrE

SizE

R2

R3

R4

R4

R1

R1

R1

R2

MOUnTing

WALL

WALL

WALL

WALL

WALL

WALL

WALL

WALL

MOdEl nUMbEr nEMA 1

PPC3-2-4A7-1

PPC3-2-6A7-1

PPC3-2-7A5-1

PPC3-2-9A8-1

PPC3-2-17A6-1

PPC3-2-24A4-1

PPC3-2-31A0-1

PPC3-2-46A2-1

drivE ProdUcTS

PPC5 Selection

208-240 Volt – 3-Phase IN, 3-Phase OUT

oUTPUT aMPS

ENcloSUrE

SiZE

MoUNTiNG

114

143

178

221

248

46.2

59.4

74.8

88

4.6

6.6

7.5

11.8

16.7

24.2

30.8

R1

R1

R1

R1

R1

R2

R2

R3

R3

R4

R4

R4

R6

R6

R6

R6

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

ModEl

NUMbEr

NEMa 1

ModEl

NUMbEr

NEMa 12

PPC5-2-4A6-1 PPC5-2-4A6-12

PPC5-2-6A6-1 PPC5-2-6A6-12

PPC5-2-7A5-1 PPC5-2-7A5-12

PPC5-2-11A-1 PPC5-2-11A-12

PPC5-2-16A-1 PPC5-2-16A-12

PPC5-2-24A-1 PPC5-2-24A-12

PPC5-2-30A-1 PPC5-2-30A-12

PPC5-2-46A-1 PPC5-2-46A-12

PPC5-2-59A-1 PPC5-2-59A-12

PPC5-2-74A-1 PPC5-2-74A-12

PPC5-2-88A-1 PPC5-2-88A-12

PPC5-2-114A-1 PPC5-2-114A-12

PPC5-2-143A-1 -

PPC5-2-178A-1

PPC5-2-221A-1

PPC5-2-248A-1

-

-

-

Specifications are based on a 3-phase supply voltage, 208 volt or 230 volt. For operation on 1-phase input power, de-rate the drive output current by 50%. Drive output is always 3-phase voltage.

400-480 Volt – 3-Phase IN, 3-Phase OUT

oUTPUT aMPS

ENcloSUrE

SiZE

MoUNTiNG

72

77

96

124

31

38

44

59

157

180

196

245

3.3

4.1

6.9

8.8

11.9

15.4

23

R4

R5

R5

R6

R3

R3

R4

R4

R6

R6

R7

R7

R1

R1

R1

R1

R1

R2

R2

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Floor

Floor

ModEl

NUMbEr

NEMa 1

ModEl NUMbEr

NEMa 12

PPC5-4-3A3-1 PPC5-4-3A3-12

PPC5-4-4A1-1 PPC5-4-4A1-12

PPC5-4-6A9-1 PPC5-4-6A9-12

PPC5-4-8A8-1 PPC5-4-8A8-12

PPC5-4-11A-1 PPC5-4-11A-12

PPC5-4-15A-1 PPC5-4-15A-12

PPC5-4-23A-1 PPC5-4-23A-12

PPC5-4-31A-1 PPC5-4-31A-12

PPC5-4-38A-1 PPC5-4-38A-12

PPC5-4-44A-1 PPC5-4-44A-12

PPC5-4-59A-1 PPC5-4-59A-12

PPC5-4-72A-1 PPC5-4-72A-12

PPC5-4-77A-1 PPC5-4-77A-12

PPC5-4-96A-1 PPC5-4-96A-12

PPC5-4-124A-1 -

PPC5-4-157A-1

PPC5-4-180A-1

PPC5-4-196A-1

PPC5-4-245A-1

-

-

-

-

The output current (or amps) of the PPC must be greater than or equal to the maximum rated motor current.

500-600 Volt – 3-Phase IN, 3-Phase OUT

oUTPUT aMPS

32

41

52

62

77

99

11

17

22

27

2.7

3.9

6.1

9

ENcloSUrE SiZE

R3

R4

R4

R4

R5

R6

R1

R2

R2

R3

R1

R1

R1

R1

MoUNTiNG

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

Wall

ModEl NUMbEr NEMa 1

PPC5-5-2A7-1

PPC5-5-3A9-1

PPC5-5-6A1-1

PPC5-5-9A0-1

PPC5-5-11A-1

PPC5-5-17A-1

PPC5-5-22A-1

PPC5-5-27A-1

PPC5-5-32A-1

PPC5-5-41A-1

PPC5-5-52A-1

PPC5-5-62A-1

PPC5-5-77A-1

PPC5-5-99A-1

ModEl NUMbEr NEMa 12

PPC5-5-2A7-12

PPC5-5-3A9-12

PPC5-5-6A1-12

PPC5-5-9A0-12

PPC5-5-11A-12

PPC5-5-17A-12

PPC5-5-22A-12

PPC5-5-27A-12

PPC5-5-32A-12

PPC5-5-41A-12

PPC5-5-52A-12

PPC5-5-62A-12

PPC5-5-77A-12

PPC5-5-99A-12

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

39

40 accESSoriES

Reactors & Filters

Increase motor life expectancy

Installing an output reactor or filter can increase motor life and performance in many applications.

Reactor Enclosed

Application

Variable frequency drives produce voltage spikes that are a function of voltage rise time and length of motor cable. In extreme cases, peak voltages may exceed three times nominal operating voltage. Ideal for use with Pentek

®

PPC3 and PPC5

Pump Controllers.

Reactors and Filters

A reactor is a resistance and inductance device that reduces the voltage spikes. This is accomplished both by increasing the voltage rise time as well as by improving the impedance match of the motor and cable.

A filter combines a reactor with a capacitor network. The capacitor network absorbs a portion of the voltage spike, further reducing the peak voltage seen by the motor.

When to use a Reactor and Filter

The chart below will provide some guidelines as to when to use a reactor or filter. Careful considerations should be given when:

Long motor lead lengths are used

Using NEMA standard, premium efficiency, submersible motors

Quality and age of the motor are unknown

Using a submersible motor over 230V

The cost of replacing the motor is prohibitive

Consistency of environment and/or power quality is unknown

Filter Enclosed

LEAD LENGTH

MOTOR TYPE

NEMA ABOVE-GROUND

STANDARD EFFICIENCY

NEMA ABOVE-GROUND

STANDARD EFFICIENCY

SUBMERSIBLE

REACTOR FILTER

230V

UP TO 50’

460V

– –

– –

230V

50’-150’

460V 230V

150’-1000’

460V

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

Reactor open

W

H

D accESSoriES

Reactors

Increase motor life by eliminating voltage spikes

Reactor enclosed

W

H

D

P e r f o r m a n c e a n d P r o t e c t i o n f o r D r i v e s .

C US

MODEL #

KDRA1PC1

KDRA2PC1

KDRA3PC1

KDRA4PC1

KDRB1PC1

KDRD1PC2

KDRD2PC2

KDRD3PC2

KDRD4PC2

KDRC1PC2

KDRF1PC3

KDRF2PC3

KDRF3PC4

KDRH1PC4

KDRI1PC4

KDRI2PC4

KDRG1PC4

RATED

AMPS

34

40

21

27

52

65

77

96

124

156

180

240

3.4

4.8

7.6

11

14

Open Design (Low-Z) – CSA Listed, 230V or 460V Input, 50/60 Hz

MODEL # RATED AMPS HEIGHT

DIMENSIONS (IN.)

WIDTH

KDRA3P

KDRA4P

KDRB1P

KDRD1P

KDRD2P

KDRD3P

KDRD4P

KDRC1P

KDRF1P

KDRF2P

KDRF3P

KDRH1P

KDRI1P

KDRI2P

KDRG1P

65

77

40

52

7.6

11

14

21

27

34

96

124

156

180

240

7

7

6

6

6

5

6

6

4

4

9

9

9

9

7

Enclosed NEMA 1 Design – CSA Listed, 230V or 460V Input

DEPTH WEIGHT LBS.

7.2

7.2

9

9

4.18

4.18

6

7.2

7.2

7.2

9

11

11

11

11

6

6

5

4

4

4

4

4

4

4

7

7

7

7

6

25

25

12

15

7

10

10

12

5

4

50

45

60

30

40

Enclosed NEMA 1 Design – CSA Listed, 575V Input

MINIMUM CAB SIZE

HEIGHT

DIMENSIONS (IN.)

WIDTH DEPTH

7.5

7.5

7.5

7.5

7.5

9

9

15.5

15.5

15.5

15.5

15.5

6.5

6.5

6.5

6.5

6.5

10

10

10

10

10

12

12

15

15

15

15

15

8

8

8

8

8

7

7

7

7

8

8

7

13

13

13

13

13

6

6

6

6

6

MINIMUM

CAB SIZE

C2

C2

C2

C2

C2

C3

C3

C4

C4

C4

C4

C4

C1

C1

C1

C1

C1

WEIGHT

LBS.

18

18

16

16

21

37

37

75

80

65

75

95

8

9

11

8

8

RATED

AMPS

125

144

192

242

77

99

52

62

22

27

32

41

11

17

2.7

3.9

6.1

9

MODEL #

KDRA31PC1

KDRA35PC1

KDRA33PC1

KDRA34PC1

KDRA36PC1

KDRD31PC2

KDRD32PC2

KDRD35PC2

KDRD33PC2

KDRD34PC2

KDRC31PC2

KDRF31PC3

KDRF32PC3

KDRF33PC4

KDRH31PC4

KDRI31PC4

KDRI32PC4

KDRG31PC4

HEIGHT

DIMENSIONS (IN.)

WIDTH DEPTH

15.5

15.5

15.5

15.5

7.5

9

9

15.5

6.5

7.5

7.5

7.5

7.5

7.5

6.5

6.5

6.5

6.5

15

15

15

15

12

15

10

12

10

10

10

10

8

10

8

8

8

8

13

13

13

13

8

13

8

7

7

7

7

7

7

6

6

6

6

6

WEIGHT

LBS.

75

75

80

95

37

65

21

37

16

18

18

21

11

16

9

8

8

8

MINIMUM

CAB SIZE

C4

C4

C4

C4

C3

C4

C2

C3

C2

C2

C2

C2

C1

C2

C1

C1

C1

C1

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

41

accESSoriES

Filters

Eliminate and dampen voltage spikes for long motor life

W

Filters Enclosed

D

H

42

Enclosed NEMA 1 Design, 230V, 460V or 575V Input

MODEL #

KLCUL4A1

KLCUL6A1

KLCUL8A1

KLCUL12A1

KLCUL16A1

KLCUL18A1

KLCUL21A1

KLCUL25A1

KLCUL27A1

KLCUL35A1

KLCUL45A1

KLCUL55A1

KLCUL80A2

KLCUL110A2

KLCUL130A2

KLCUL160A2

KLCUL200A3

KLCUL250A3

MODEL #

KLC4BE

KLC6BE

KLC8BE

KLC12BE

KLC16BE

KLC25BE

KLC35BE

KLC45BE

KLC55BE

KLC80BE

KLC110BE

KLC130BE

KLC160BE

KLC200BE

KLC250BE

RatED aMPS

4

6

8

45

55

80

110

12

16

25

35

130

160

200

250

HZ

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

Enclosed NEMA 1 Design, CUL Listed, 230V, 460V or 575V Input

HEigHt

6.5

6.5

6.5

7.5

7.5

9

16

6.5

6.5

7.5

7.5

16

16

16

16

DiMEnSiOnS (in.)

WiDtH

10

10

12

15

8

8

10

10

15

15

15

15

8

8

8

RatED aMPS

25

27

35

45

12

16

18

21

55

80

110

130

160

200

250

4

6

8

HZ

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

50/60

HEigHt

12.25

12.25

12.25

12.25

12.25

12.25

12.25

12.25

12.25

12.25

12.25

12.25

19.13

19.13

19.13

19.13

22.13

22.13

DEPtH

8

13

7

7

6

6

7

7

13

13

13

13

6

6

6

WEigHt LbS.

9

9

11

96

100

115

116

18

19

32

88

11

13

16

17

DiMEnSiOnS (in.)

WiDtH

12.5

12.5

12.5

12.5

12.5

12.5

12.5

12.5

12.5

12.5

12.5

12.5

15.5

15.5

15.5

15.5

20.5

20.5

DEPtH

6.75

6.75

6.75

6.75

6.75

6.75

6.75

6.75

6.75

6.75

6.75

6.75

15.5

15.5

15.5

15.5

24.37

24.37

WEigHt LbS.

15

15

15

21

21

22

22

23

60

64

15

18

21

21

70

84

108

117

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

P 8177 WS

accESSoriES

Transducers, Leads & Repair Parts

Pentek Intellidrive

Repair Parts

ModEl #

PID-CON2

PID-CON3

PID-FAN

PID-HMI

U17-1561

U18-1593R

U18-1594R

U18-1595R

U18-1596R

U18-1597R

U18-1598R

iTEM

2-POLE CONNECTOR (LINE IN)

3-POLE CONNECTOR (LINE OUT)

REPLACEMENT FAN

REPLACEMENT KEYPAD

TRANSDUCER (PID CONTROL)

TRANSDUCER CABLE, FOR U17-1561

TRANSDUCER CABLE, FOR U17-1561

TRANSDUCER CABLE, FOR U17-1561

TRANSDUCER CABLE, FOR U17-1561

TRANSDUCER CABLE, FOR U17-1561

TRANSDUCER CABLE, FOR U17-1561

dEScriPTioN

2-POLE CONNECTOR (LINE IN)

3-POLE CONNECTOR (LINE OUT)

REPLACEMENT FAN

REPLACEMENT KEYPAD

0 – 100 PSIG, 4~20MA, LESS LEAD

10 FT. – 18-GAUGE SHIELDED

25 FT. – 18-GAUGE SHIELDED

50 FT. – 18-GAUGE SHIELDED

100 FT. – 18-GAUGE SHIELDED

150 FT. – 18-GAUGE SHIELDED

200 FT. – 18-GAUGE SHIELDED

MaNUFacTUrEr

PENTEK

PENTEK

PENTEK

PENTEK

PENTEK

PENTEK

PENTEK

PENTEK

PENTEK

PENTEK

PENTEK

PPC3/PPC5 Repair Parts

ModEl #

U17-1336

U97-188

U97-189

U97-190

U17-1329

U17-1330

U17-1331

U17-1332

U17-1333

U17-1334

U17-1335

iTEM

PPC3/PPC5 CONTROL PANEL (KEYPAD)

DRIVE WINDOWS LIGHT

PPC5 jUMPER COMB

PPC3 jUMPER COMB

TRANSDUCER

TRANSDUCER

TRANSDUCER

TRANSDUCER

RIGHT ANGLE LEAD, FOR U17-1329 TO 1332

RIGHT ANGLE LEAD, FOR U17-1329 TO 1332

RIGHT ANGLE LEAD, FOR U17-1329 TO 1332

dEScriPTioN

PPC3/PPC5 CONTROL PANEL (KEYPAD)

DRIVE WINDOWS LIGHT

PPC5 jUMPER COMB

PPC3 jUMPER COMB

0-60 PSIG, 4~20MA, LESS LEAD

0-100 PSIG, 4~20MA, LESS LEAD

0-200 PSIG, 4~20MA, LESS LEAD

0-500 PSIG, 4~20MA, LESS LEAD

2-WIRE, 6.5 FEET

2-WIRE, 13.0 FEET

2-WIRE, 19.6 FEET

MaNUFacTUrEr

PENTEK

PENTEK

PENTEK

PENTEK

TURCK

TURCK

TURCK

TURCK

TURCK

TURCK

TURCK

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

43

NoMENclaTUrE

Nomenclature

4" Submersible Motors

P 42 B 0005 A 1

Brand

P – PENTEK

®

Motor Size

42 – Four Inch 2-Wire

Motor Material

A – Stainless Steel w/Cast Iron End Bells

43 – Four Inch 3-Wire B – All Stainless Steel

HorSepower

0005 – 1/2 HP

0007 – 3/4 HP

0010 – 1 HP

0015 – 1-1/2 HP

0020 – 2 HP

0030 – 3 HP

0050 – 5 HP

0075 – 7-1/2 HP

0100 – 10 HP

Frequency

A – 60 Hz

B – 50 Hz

C – 50/60 Hz

Voltage / pH

1 – 115V, 1 PH

2 – 230V, 1 PH

3 – 230V, 3 PH

4 – 460V, 3 PH

5 – 575V, 3 PH

8 – 200V, 3 PH

6"-14"

Submersible Motors

6 HIT 2 - 15 - 1

®

MOTOR DIAMETER

6

8

10

12

14

HITACHI MOTOR

HIT/PM

POLE

2 = 2-POLE

4 = 4-POLE

HORSEPOWER

15 = 15 HP

VOLTAGE/PH

1 - 230V, 1-PHASE

2 - 230V, 3-PHASE

4 - 460V, 3-PHASE

8 - 200V, 3-PHASE

PPC Model Number Key

PPC5-4-4A1-1

SERIES

PPC5

PPC3

INPUT VOLTAGE

2 – 230V, 3 PH

4 – 460V, 3 PH

OUTPUT AMP RATING

4A1

4A1 = 4.1 AMPS

5 – 575V, 3 PH (Amps A tenths)

The output current (or amps) of the PPC must be greater than or equal to the maximum rated motor current. Output of all drives is 3-phase power.

ENCLOSURE RATING

1 (NEMA 1)

12 (NEMA 12)

PENTEK INTELLIDRIVE

SERIES

PID

PID-50

VOLTAGE

1-230V 1-Phase In/230V 3-Phase Out/1-Phase Out

44

Hitachi

®

is a registered trademark of Hitachi Industrial Equipment Systems Co., Ltd.

hORSEpOwER

50=5HP

ENCLOSURE RATING

3 (NEMA 3R)

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

Global oPEraTioNS

Global Operations

Pentair is the premier supplier of innovative products and systems used worldwide in the movement, treatment, storage and enjoyment of SAFE, CLEAN WATER.

Pentair is operating in more than 50 locations worldwide, and is positioned to serve the global marketplace with innovative products while improving life and industry.

americas

Anaheim, CA

Ashland, OH

Aurora, IL

Brantford, Ontario

Brookfield, WI

Chardon, OH

Cypress, CA

Delavan, WI

Denham Springs, LA

Dover, NH

El Monte CA

Grand Island, NE

Hanover Park, IL

Kansas City, KS

Kitchener, Ontario

LaGrangeville, NY

Minneapolis, MN

Monterrey, Mexico

Moorpark, CA

New Brighton, MN

Reynosa, Mexico

Sanford, NC

Sheboygan, WI

South El Monte, CA

Union City, TN

Europe

Billingham, UK

Buc, France

Cambridge, UK

Colombes, France

Crawley, UK

Griesheim, Germany

Herentals, Belgium

Houilles, France

Montespertoli, Italy

Pisa, Italy

Pregnana, Italy

international

Auckland, New Zealand

Goa, India

Johannesburg, S.A.

Melbourne, Australia

New Delhi, India

Santiago, Chile

Shanghai, China

Suzhou, China

PENTEK cUSToMEr HoTliNE: 1-866-9PENTEK

45

46

This Page Intentionally Left Blank

PENTEK CusTomEr HoTliNE: 1-866-9PENTEK

This Page Intentionally Left Blank

PENTEK CusTomEr HoTliNE: 1-866-9PENTEK

47

PENTEK

®

293 WRIGHT STREET, DELAVAN, WI 53115 WWW.PUMPS.COM

PH: 866-9-PENTEK ORDERS FAX: 800-426-9446

Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice.

© 2014 Pentair Ltd. All Rights Reserved.

P8063WS (04/08/14)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement