Lennox Hearth | CA210 | C210 | SWI210 | User manual | INSTALLATION AND OPERATION MANUAL

Add to my manuals
24 Pages

advertisement

Lennox Hearth | CA210 | C210 | SWI210 | User manual | INSTALLATION AND OPERATION MANUAL | Manualzz

INSTALLATION AND OPERATION MANUAL

EPA Certified

Wood-Burning

Fireplace Inserts

Save These Instructions

For Future Reference

Performer™ C210 and SWI210

P/N 775212M, Rev. C, 09/2011

Performer™ CA210

Wood Fireplace Inserts

Performer™ Models C210,

CA210 and SWI210

A French manual is available upon request. Order P/N 775212CF.

Ce manuel d’installation est disponible en francais, simplement en faire la demande. Numéro de la pièce 775212CF.

US

This appliance must be properly installed and operated in order to prevent the possibility of a house fire. Please read this entire installation and operation manual before installing and using your wood fireplace insert. Failure to follow these instructions could result in property damage, bodily

Portland injury or even death. Contact your local building or fire officials to obtain a permit and information on any installation re-

Report No. 050-S-03b-2 quirements and inspection requirements in your area.

WARNINGS

• Hot! Do not touch! The glass and surfaces of this appliance will be hot during operation and will retain heat for a while after shutting off the appliance. Severe burns may result.

• Carefully supervise children in the same room as appliance.

2

CONGRATULATIONS!

When you purchased your new wood-burning fireplace insert, you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for aesthetics, efficiency and our environment. We extend our continued support to help you achieve the maximum benefit and enjoyment available from your new wood-burning fireplace insert.

Thank you for selecting a Lennox Hearth Products wood-burning fireplace insert as the answer to your home heating needs.

TABLE OF CONTENTS

Insert Pre-Installation Preparation ............................................... 10

Chimney Liner Installation ........................................................... 12

Installing the Insert ...................................................................... 12

Post Installation Checks ............................................................... 12

Operating Hints ............................................................................ 13

Starting and Maintaining a Fire .................................................... 13

Blower Operation (optional kit) .................................................... 14

Operating Techniques and Hints................................................... 15

Getting the Most Out of Your Fireplace Insert .............................. 15

Maximizing Your Fireplace Insert’s Overall Efficiency ................... 15

Achieving Clean, Long Burns ....................................................... 15

Maintenance ................................................................................. 16

Clean Glass .................................................................................. 16

Troubleshooting ........................................................................... 17

Do’s and Don’ts ............................................................................ 18

Replacement Parts List ...........................................................19-21

Accessories .................................................................................. 22

Safety / Listing Labels .................................................................. 23

Product Reference Information .................................................... 24

Using This Manual ......................................................................... 2

Important Safety Information ......................................................... 3

Testing Information ........................................................................ 4

Draft Requirements ........................................................................ 4

Selecting the Proper Venting System ............................................. 4

Negative Pressure Warning ............................................................ 5

Creosote ......................................................................................... 5

Ash Disposal .................................................................................. 5

Fuel ........................................................................................... 5

Burn-In Period ............................................................................... 5

Paint Curing ................................................................................... 5

Brick Installation ............................................................................ 6

Required Clearances ...................................................................... 7

Hearth Protection ........................................................................... 8

Chimney Requirements .................................................................. 9

Installation Procedures-Masonry Chimney .................................... 9

Positive Flue Connection .............................................................. 10

Installation Procedure - Factory-Built Zero Clearance Fireplaces 10

Fireplace Pre-Installation Preparation .......................................... 10

USING THIS MANUAL

Please read and carefully follow all of the instructions found in this manual. Please pay special attention to the safety instructions provided in this manual.

PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE

IMPORTANT SAFETY AND WARNIING

INFORMATION

READ THIS MANUAL IN ITS ENTIRETY AND UNDER-

STAND THESE RULES TO FOLLOW FOR SAFETY.

1. When this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.

2. Wear gloves during installation to avoid injury from sharp edges on the insert and/or its parts.

3. This unit is designed and engineered to burn only dry, wellseasoned wood. Burning wet wood will greatly reduce your inserts efficiency, produce excessive amounts of smoke and can cause dangerous chimney fires due to creosote buildup.

4. Before opening the door, the draft control must be fully open

to avoid possible combustion flash (ignition of hot volatile gases as the door is opened).

5. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or ’freshenup’ a fire in this heater. Keep all such liquids well away from the heater while it is in use.

6. While burning, fuel utilizes oxygen from the air in the room.

Be sure to allow an adequate amount of fresh air into the room where the insert is burning.

7. The outside surface of the insert will be hot while burning properly and can set items like clothing and curtains on fire.

Keep furnishings and other combustible materials away from the insert. Using the heat from the insert to dry wet clothing can be hazardous if clothes are placed too near the surface of the insert.

8. Do not allow children to play near the insert without close supervision. Do not touch the insert while it is burning. Use extreme caution while the unit is in use. Surface temperatures become dangerously hot and can cause serious burns.

9. Do not allow anyone to operate the insert who is not familiar with the operating instructions.

10. Attempts to achieve heat output rates that exceed insert design specifications can result in permanent damage to the insert.

Never leave your insert unattended on high burn rates. This may cause overfiring. Overfiring the insert may cause a house fire. If the insert glows, you are overfiring.

11. Keep a water hose or hand-operated fire extinguisher close for safety.

12. Smoke Detectors - Since there are always several potential sources of fire in any home, we recommend installing smoke detectors. If possible, install the smoke detector in a hallway adjacent to the room (to reduce the possibility of occasional false activation from the heat produced by the insert). If your local code requires a smoke detector be installed within the same room, you must follow the requirements of your local code. Check with your local building department for requirements in your area.

13. Inspect your chimney at least once a month during the burning season to check for soot and creosote accumulations.

Any accumulations over 1/8” thick should be removed by a professional chimney sweep. Do not attempt to burn out heavy creosote accumulations with a hot fire. If large accumulations are occurring, review your burning procedures.

14. If a creosote fire should develop, the fire department should be called immediately and then attempts should be made to control the fire until assistance arrives. If a “runaway” fire should develop causing over-heating of the insert, the door and draft regulators should be closed immediately. The fire should die down once deprived of oxygen. After a severe chimney fire, the complete chimney system should be checked before further use.

15. Do Not Use Grate Or Elevate Fire - Build Wood Fire Directly

On Hearth (firebrick). Do not use andirons or other methods of supporting the fuel.

16. Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result in property damage, bodily injury, or even death.

17. Check all local building and safety codes before installation.

The installation instructions and appropriate code requirements must be followed exactly and without compromise.

In the absence of local codes the following standards and codes must be followed.

18. In the U.S.A, install in accordance with the National Fire

Protection Association’s Code, NFPA 211, Standards for

Chimneys, Fireplaces, Vents and Solid-Fuel-Burning Appliances, or similar regulations, may apply to the installation of a Solid-Fuel-Burning appliance in your area. In Canada, the guideline is established by the CSA Standard, CAN/CSA-B365-

M93, Installation Code for Solid-Fuel-Burning Appliances and

Equipment.

19. Do not connect to any air distribution duct or system.

20. WARNING: BURNING IMPROPER FUEL (I.E. CHARCOAL)

CAN RESULT IN CARBON MONOXIDE POISONING, WHICH

MAY LEAD TO DEATH!

21. Carbon Monoxide Poisoning – early signs of carbon monoxide poisoning resemble the flu with headaches, dizziness, or nausea. If you have these signs, get fresh air at once! Have the heater inspected by a qualified service technician. Some people are more affected by carbon monoxide than others.

These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

22. Failure to use manufacturer provided parts, variations in techniques and construction materials or practices other than those described in this manual may create a fire hazard and void the limited warranty.

23. Do not make any make-shift compromises during installation.

Any modification or alteration may result in damage to the appliance or dwelling and will void the warranty, certification and listings of this unit.

24. These appliances are designed as supplemental heaters.

Therefore, it is advisable to have an alternate heat source when installed in a dwelling.

25. Do Not Overfire – If Heater or Chimney Connector Glows,

You Are Overfiring.

26. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING

ANOTHER APPLIANCE.

3

4

TESTING INFORMATION

This manual describes the installation and operation of these non-catalytic wood heaters. These heaters meet the U.S. Environmental Protection

Agency’s emissions limits for wood heaters sold on or after July 1, 1990.

This heater has been developed, tested and constructed in accordance with the requirements of UL 1482, ULC S628 and HUD standards and is listed by OMNI Test Laboratories, Portland, OR. It has been approved for residential and alcove installations.

DRAFT REqUIREMENTS

Your wood fireplace insert is dependent upon a properly functioning chimney for optimum performance. It is a high efficiency appliance that loses much less heat up the chimney than older appliances and fireplaces.

For this reason it is important to match the fireplace insert to the chimney.

The chimney has two functions:

1. It draws combustion air into the appliance (without air, no fuel will burn) and

2. It exhausts combustion by-products. Your new appliance is what is known as a “natural draft” appliance.

The appliance depends solely on the natural draft of the chimney system to draw combustion air into the unit. Draft is the force that moves air from the appliance up into the chimney. The amount of draft in your chimney depends on the length of the chimney, local geography, nearby obstructions and other factors. Too much draft may cause excessive temperatures in the appliance (overfiring). Slow or inadequate draft equals poor combustion and possible smoking problems. The following are some conditions that may contribute to poor chimney draft:

1. A chimney too large for your appliance.

2. A chimney with not enough height to produce adequate draft.

3. A chimney with excessive height (this may allow exhaust to cool too much before exiting, which will stall the rate the exhaust exits).

4. Offsets in the venting system are too restrictive (see Chimney Guide-

lines).

Inadequate draft will cause the appliance to leak smoke into the room through the fireplace insert and the chimney connector joints.

Excessive draft may cause an uncontrollable burn or a glowing red fireplace insert or chimney part.

Overfiring Damage - If the heater or chimney connector glows, you are overfiring. Other symptoms may include: Cracking, warping or burning out of components, plated accessories may turn color, stove glass may develop a haze, which will not come off with cleaning.

Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached, beyond the design capabilities of the appliance. The damage that occurs from overfiring is not covered under the manufacturer’s limited warranty.

Also see Troubleshooting on Page 17.

read greater than .04’ W.C. (inches water column) and less than .08”

W.C. As per NFPA-211 standard (see paragraph below), the installer must take into account all variables within the installation and install the appliance in such a manner that satisfies the draft requirements of the appliance. See Chimney Guidelines below to assist you in selecting the proper venting system for your installation.

American National Standards Institute ANSI/NFPA 211, Standard for

Chimneys, Fireplaces, Vents, and Solid Fuel-Burning Appliances

- See Draft Section: A chimney or vent shall be so designed and constructed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere. The venting system shall satisfy the draft requirements of the connected appliance in accordance with the manufacturer’s instructions.

Chimney Guidelines:

• This appliance requires approximately 12 feet minimum of “effective draw” provided by the venting system. As a rule of thumb, every 90 degree total direction change in the venting will result in a loss of approximately 5 feet of “effective draw.” Example: If two 45 degree offsets are used, subtract 5 feet from the actual vertical vent height to determine your “effective draw.” In this case if you had 14 feet of vertical vent, the effective draw would only be approximately 9 feet

(14 ft. - 5 ft. = 9 ft.), therefore it may be necessary to add additional height to the venting system.

• In well insulated and weather tight homes, it may be difficult to establish a good draft up your chimney. The poor draft is caused by a shortage of air in the house (see Negative Pressure Warning on Page 5).

Chimney Height Requirements

The chimney must extend 3’ (.92m) above the level of roof penetration and a minimum of 2’ (.61m) higher than any roof surface within 10’

(3m) (see below). Check with your local building officials for additional requirements for your area.

Figure 1

Less than

10' (3 m)

3' (914 mm)

Min.

2’ (610 mm) Min.

- Chimney Height Requirements

10'

(3 m)

3'

(914 mm)

Min.

SELECTING THE PROPER VENTING SYSTEM

The appliance is merely one component of a larger system. The other equally important component is the venting system. This is necessary for achieving the required flow of combustion air to the fire chamber and for safely removing unwanted combustion by-products from the appliance.

If the venting system’s design does not promote these ends, the system may not function properly. Poorly functioning venting systems may create performance problems as well as be a safety hazard. A draft test should

To pass inspection in nearly any jurisdiction, the chimney must meet both safety and exhaust flow requirements. The (3’ by) 2’ by 10’ rule applies to both masonry and factory-built chimneys.

* Ref. USA - National Standard, NFPA 211-latest edition and Canada

National Standard CSA B365-01-latest edition. Vents installed with a listed cap shall terminate in accordance with the terms of the cap’s listings.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

NEGATIVE PRESSURE WARNING

This appliance is not designed to be operated in a negative pressure.

In very airtight homes with large kitchen exhaust fans, furnace cold air returns, fresh air exchange systems and any other air system in close proximity to the heating appliance may create a negative pressure in the same room as the heating appliance. This can create dangerous back drafting of the fireplace insert and chimney joints, drawing combustion by-products into the home. Be sure your home has adequate makeup air to eliminate negative pressures caused by the above-mentioned sources.

Lennox Hearth Products accepts no liability for damages resulting from negative pressures described above.

Ventilation Requirements - Provide adequate air for combustion. The fresh air requirements of this appliance must be met within the space where it will be installed. Ventilation is essential when using a Solid-Fuel-

Burning heater. In well insulated and weather tight homes, it may be difficult to establish a good draft up the chimney (caused by a shortage of air in the home). The lack of air is caused by many common household appliances which exhaust air from the home (such as a furnace, heat pump, air conditioner, clothes dryer, exhaust fans, fireplaces, and other fuel burning appliances). Also, the combustion process of this heater uses oxygen from inside the dwelling. If the available fresh air delivery in the dwelling is insufficient to support the demands of these appliances, problems can result (i.e. excessive negative pressure can develop in the dwelling which will affect the rate at which this appliance can draft thus resulting in performance problems. To correct this problem it may help to open a window (preferably on the windward side of the house).

CREOSOTE, FORMATION AND NEED FOR REMOVAL

When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire. The chimney and chimney connector should be inspected at least once monthly during the heating season to determine if a creosote buildup has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire.

DISPOSAL OF ASHES

Ashes should be scooped out of a cool fireplace insert with a small metal shovel. Ashes should be placed in a metal container with a tight fitting lid and moved outdoors immediately. Other waste shall not be placed in this container. The closed container of ashes should be placed on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all the cinders have thoroughly cooled. Ashes can ignite up to 72 hours after removal from the fireplace insert.

FUEL

This unit is designed and engineered to burn, dry, well-seasoned wood only.

Dry, seasoned wood is that which has been cut, split and allowed to dry under a covered area where air is free to flow and circulate under and around the wood (not under a tarp or plastic). Make sure wood is not stacked directly on the ground, it may absorb moisture from the ground.

It should be allowed to dry in these conditions for a minimum of six months, preferably one year or more. IT MUST BE UNDERSTOOD THAT

WOOD CANNOT BE LEFT IN ANY KIND OF WET OR DAMP AREA OR IT

WILL NEVER BECOME COMPLETELY SEASONED. Your fireplace insert will not operate at the level that it is meant to unless you use seasoned, dry wood. Do not burn driftwood or wood that has been in salt water, doing so will void your warranty. Do not burn treated wood, coal, garbage, cardboard, solvents, or colored paper. Burning treated wood, garbage, solvents, or colored paper may result in the release of toxic fumes. This type of burning will also void your warranty.

PAINT CURING

If your fireplace insert has plated accessories, be sure to clean it with a household type glass cleaner and a very soft cloth to remove any fingerprints and residues prior to the first fire and before any fire if the gold has been handled or soiled. Do not close the door tightly during the “Burn-In Period.” Also, open the door frequently (every

5-10 minutes) to keep the gasket from adhering to the curing paint.

Ventilate the house well during these first firings as the paint gives off carbon dioxide and unpleasant odors. It is recommended that persons sensitive to an imbalance in the indoor air quality avoid the fireplace insert during the curing process.

Your new appliance is painted with a high temperature paint that cures during the first few firings. We recommend that you put your fireplace insert through a regimen of three burns. The first two should last for 20 minutes each at 250 degrees (the fireplace insert should be allowed to cool completely between each burn). The third should be a burn of at least

450 degrees F. for 45-60 minutes. The paint will become soft, gummy and emit non-toxic smoke during these burns. After the fireplace insert cools down for the third time, the paint will harden. DO NOT BUILD A

LARGE ROARING FIRE UNTIL THIS CURING EFFECT IS COMPLETE OR

YOU MAY DAMAGE THE FINISH OF YOUR STOVE OR INSERT. Spray can touch-ups should be done only with a high temperature stove paint

(cat. no. H8159), available from all Lennox Hearth Products dealers.

BURN-IN PERIOD

Please be patient with the heat output of your fireplace insert for the first few weeks. The steel will go through a curing process that eliminates moisture, which is deep in the steel and firebrick. This moisture will reduce initial heat output of your fireplace insert and may make it difficult to start. After you have broken in the paint on the fireplace insert it will be necessary to build hot fires to thoroughly remove the moisture from the appliance. Running the fireplace insert with the draft fully open for 1 to 1-1/2 hours after starting and adding generous amounts of fuel during the first week or two should complete the curing process. We recommend the use of a thermometer attached to the fireplace insert top or chimney. Temperatures on the connector pipe should run in the

250-600 degree range. (DO NOT OVERFIRE THE STOVE OR INSERT

DURING THIS PROCESS. IF THE STOVE OR CHIMNEY BECOMES

RED, REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR

INSERT IMMEDIATELY).

5

6

BRICK INSTALLATION

CAUTION: Wear gloves during brick installation in case of sharp edges behind the fireplace insert.

Note: Installation of the baffle boards and baffle blankets are easier when

you can still access the flue outlet, (before connecting the flue vent). Be sure the baffle blankets are placed flat on the baffle boards so as not

to block exhaust flow to the flue. Use a ruler or a piece of kindling to reach over the baffle blanket to be sure it is completely flat on top of the baffle boards.

Measure bricks before installing, as per list of dimensions on next page, to be sure the correct bricks are installed in the correct location.

1. Install bricks #1-26 in the numbered sequence shown in Figure 2.

Important: The secondary burn tubes at the top of the firebox are supported by a metal bracket. Move this bracket so it is centered left and right on the tubes. Also make sure the small supporting brackets on the front and rear tubes are centered and hanging from the steel rods at the front and rear of the fireplace insert.

2. Next, you will install the baffle boards. All 4 baffle boards included are the same size which is 15” x 4-3/4”. You will start by installing the boards in the center part of the unit on top of the secondary tubes to each side of the baffle support with the 15” side of the baffle board going from the front to back of the unit. Once you have the first two boards installed slide the board to the left side of the baffle support all the way to the left and rear of the unit. You will slide the board to the right side of the secondary support to the right and rear of the unit. Next you will install the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit. The stainless steel support hanger should be centered left to right between the sets of baffle boards and placed as shown in

Figure 4.

3. Also included with the unit are two 15” x 10” x 1” thick baffle blankets. Install each blanket above the baffle board to each side of the secondary support with the 15” side of the blanket from front to rear of the unit. Make sure that the baffle blankets are to the full rear of the unit.

4. Also included with the unit are two 15” x 10” x 1” thick baffle blankets. Install each blanket above the baffle board to each side of the secondary support with the 15” side of the blanket from front to rear of the unit. Make sure that the baffle blankets are to the full rear of the unit.

CAUTION: Make sure the baffle blankets are down flat on the baffle boards, pulled together in the center so that no gaps exists between them and do not protrude beyond baffle boards. It is critical that baffle boards and baffle blankets are fully against the rear of the unit.

WARNING: IF THE BRICKS ARE NOT INSTALLED EXACTLY AS

SHOWN BELOW, THEY COULD FALL OUT OF PLACE DURING

REFUELING OR BURNING OF THE FIREPLACE INSERT CAUSING

SERIOUS INJURY!

Brick Sizes (see Figures on this page)

E = 3 x 9”

F = 4-1/2 x 9”

G = 1-1/2 x 9”

H = 1-1/2 x 3”

K = 1-1/2 x 5-1/2”

S = 2-1/8”

Figure 2

Firebox Brick Layout Viewed From the Front

24

E

25

H

26

E

Baffle

Insulation

Parts

Side Cut-A-Way

View of Firebox

Baffle

Board

9

S

8

F

7

F

6*

F

14

F

1

F

Firebox

Brick

19

B

20

B

2

F

3

G

4

F

15

F

16

G

17

F

21

K

22

B

1” Thickness

Two Baffle Blankets Per Unit

1/2” Thickness

Four Boards Per Unit

5

F

18

F

10*

F

11

F

12

F 13

S

23

B

* Bricks 6 and 10 fit up against the back of the firebox.

Front View - See the following for brick sizes

*Fits against the back of the firebox.

Note: These bricks may be slightly smaller to adjust for steel and firebrick tolerances beyond our control. Be sure to measure and mark bricks with their numbers when removing.

Figure 3

15”

15”

Baffle Blankets

10”

4-3/4”

Figure 4

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

REqUIRED CLEARANCES

WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE

HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC-

TION IS NOT LESS THAN SHOWN ON THIS PAGE.

Model

C/A210

SWI210

C/A210 & SWI210 w/mantel and/or

side shields u

*A

USA-24”

CAN-

813mm

USA-16”

CAN-

813mm

*B

USA -18”

CAN-

660mm

USA -10”

CAN-

660mm

*C

18”

450mm

*D

15”

381mm

18”

450mm

USA-8”

381mm

E(1)

USA-8"

CAN-

200mm

USA-8"

CAN-

200mm

C

Maximum Mantel Depth = 9” (229mm)

COMBUSTIBLE MANTEL

Top Facing / Trim

A

B

D

Insert

Hearth Protection

Model

C/A210

SWI210

C/A210 & SWI210 w/mantel and/or

side shields u

F (1)

18”

450mm

18”

450mm

G

12-1/4”

311mm

12-1/4”

311mm

H

19”

483mm

19”

483mm

J(2)

4-1/2”

114mm

4-1/2”

114mm

M

42-1/8”

1070mm

34-1/8”

867mm

* Reduced clearances may be available for A, B, C and D dimensions per

NFPA 211 - latest edition, Standard for Chimneys, Fireplaces, Vents and

Solid Fuel-Burning Appliances (in Canada CSA B365 - latest edition). See section on “Reduction of Appliance Clearance with Specified Forms of

Protection.”

** Side view of optional mantel deflector shown.

(1)Hearth extension reductions: 2” (51 mm) reduction for 2” (51 mm) raised hearth. (USA) 16” minimum hearth extension on all stoves and inserts as measured from the door opening of the unit. (Canada) 18”(450 mm) minimum hearth extension on all stoves and inserts as measured from the door opening of the unit. Minimum distance of floor protection to the side

= 8” (200 mm). This is measured from the sides of the door opening in the

USA and from the sides of the insert in Canada.

(2) J = Maximum lintel depth without flue offset or smoke deflector.

Notes:

• Facing material that projects more than 3/4” (19 mm) from the wall is considered a mantel or side wall.

Figure 5

M

E (USA)

F

Mantel

**

Hearth Protection

Trim

9”

229mm

E (Canada)

G

J

6” Ø

Flue Collar

H

Figure 6

C/A210

SWI210

Depth Min.

Height Min.

Width Min.

ZC Fireplace

UL 127

12-1/2” (318mm)

21” (533mm)

36” (914mm)

4-1/2” (114mm) Lintel Max. Depth u u Without use of adjustable offset box or smoke deflector

Table 1 - Fireplace Sizing

Masonry Fireplace

UBC Chapter 37

12-1/2” (318mm)

19-1/4” (489mm)

26” (660mm)

4-1/2” (114mm)

Top View

23”

584mm

25-1/2”

648mm

Figure 7

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

7

8

HEARTH PROTECTION

The hearth and/or floor protection must be a thermally rated non-combustible hearth/floor protector meeting or exceeding a thermal rating of k=.84 or equivalent with a listed thickness of 3/8" (9.5mm) minimum in

USA (3/4" - 19mm minimum in Canada). The covering must extend 18”

(450mm) in front of the heater and 8” (200mm) to either side (measured from door opening in the USA and measured from the side of the unit in Canada).

Using Alternate Material As Floor / Hearth Protection

The hearth extension or alternate material used as a floor/hearth protector must be constructed of a durable noncombustible material having an equal or better thermal conductivity value (lower k value) of k =.84

BTU/IN FT2 HR °F or a thermal resistance that equals or exceeds r = 1.19

HR °F FT2 IN/BTU with a minimum thickness of 3/8” in USA or 3/4” in

Canada. With these values, determine the minimum thickness of the alternate material required using the formula(s) and shown in Table 2

for USA and Table 3 for Canada.

Note: Any noncombustible material having a minimum thickness of

3/8”(9.5 mm) for USA or 3/4” (19mm) in Canada whose k value is less than .84 or whose r value is more than 1.19 is acceptable. If the alternate material used has a higher k value or lower r value will require a greater thickness of the material used. In some cases, if the k value is less or the r value higher, a thinner material may be used.

Methods of determining floor protection equivalents:

To determine the thickness required for the alternate material when either the "k" value or "r" value is known, use either the k formula or r

formula.

Example: If Micore 160 Mineral Fiber Board is to be used for the floor protection, how thick must this material be?

r k

M

= k value per inch of alternate material

= r value per inch of alternate material

T

M

T

M

= minimum thickness required for alternate material

S

= standard thickness of the alternate material r k

L

= k value per inch of listed material

T

L

L

= r value per inch of listed material

= minimum thickness of listed material

Note: An asterisk "*" indicates, it is a value taken from Tables 2 and 3.

Using the k formula:

FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS

Using the k formula:

Minimum k-value (per Inch) of

thickness of = alternate material (k

M

) x alternate

material (T

M

) k-value (per inch)

of listed material (k

L

)

Specified min.

thickness of listed

material (T

L

)

T

M

(inches) = k

M

*.84 x T

L

.375" T

M

(inches) = *.35 x

*.84

.156 (inches)= .417 x .375"

Answer - The minimum required thickness of the Micore 160 is .156" therefore round up to nearest standard thickness available which is 3/8” (.375”)

Using the r formula:

Minimum r-value (per Inch) thickness of = of listed material alternate material r-value (per inch) of alternate material x

T

M

(inches) = r

L

r

M x

T

M

(inches) = *1.19 x

*2.86

Specified min.

thickness of listed material

T

L

.375"

.312 (inches)= .416 x .375"

Answer - The minimum required thickness of the Micore 160 is .156" therefore round up to near est standard thickness available which is

3/8” (.375”)

Listed Material

Listed Material k (per inch) r (per inch)

.84

K

L

1.19

r

L

Listed Min. Thickness

3/8 " (.375")

T

L

** Approved Alternate Materials for Floor/Hearth Protection

Alternative Materials Thermal Values Minimum Thickness

(rounded to nearest 1/8 inch)

Kaowool M Board

Micore 160™

U.S. Gypsum

Micore 300™

U.S. Gypsum k (per inch)

K

M

.47

.35

.46

r (per inch) r

M

2.13

2.86

2.17

Min. Thickness

T

M

.42" (1/2")

.31" (3/8")

.41" (1/2")

Durock™ Cement Board

U.S. Gypsum

Hardibacker™

Hardibacker 500™

Cultured Stone Hearthstone™

Wonderboard

Super Firetemp M

Johns-Manville

Super Firetemp L

Johns-Manville

Face brick

Common brick

1.92

1.95

2.30

2.82

3.23

.61

.54

9.00

5.00

Cement mortar

Ceramic tile

Marble

5.00

12.5

~11

Table 2 - USA REQUIREMENTS

.52

.31

1.64

1.85

.111

.20

.20

.08

~.09

.51

.43

.35

1.71" (1-3/4")

1.74" (1-3/4")

2.05" (2-1/8")

2.52" (2-5/8")

2.88" (3")

.54" (5/8")

.48" (1/2")

8.04" (8-1/8")

4.46” (4-1/2")

4.46” (4-1/2")

11.16" (11-1/4")

9.82" (9-7/8")

** If the hearth extension material(s) that is intended to be used is NOT listed on Table 1, the material can still be used if the material(s) is noncombustible.

However, the manufacturer of the material must provide either the listed k-value per inch or r-value per inch with listed thickness so that the minimum thickness required for the hearth can be calculated (per instructions here or as specified in the NFI Certification Manuals).

Note: Also see NFI (National Fireplace Institute) Certification Manuals showing other acceptable calculation methods and acceptable alternate materials which can be used.

SEE TABLE 3 ON FOLLOWING PAGE FOR CANADA REQUIRE-

MENTS

FOLLOWING EXAMPLES ARE CALCULATED FOR CANADA REQUIR-

MENTS

Using the k formula:

Minimum k-value (per Inch) of

thickness of = alternate material (k

M

) x alternate

material (T

M

) k-value (per inch)

of listed material (k

L

)

Specified min.

thickness of listed

material (T

L

)

T

M

(inches) = k

M

*.84 x T

L

.75" T

M

(inches) = *.35 x

*.84

.312 (inches)= .417 x .75"

Answer - The minimum required thickness of the Micore 160 is .312" therefore round up to nearest standard thickness available which is 3/8” (.375”)

Using the r formula:

Minimum r-value (per Inch) thickness of = of listed material alternate material r-value (per inch) of alternate material x

T

M

(inches) = r

L

r

M x

T

M

(inches) = *1.19 x

*2.86

Specified min.

thickness of listed material

T

L

.75"

.312 (inches)= .416 x .75"

Answer - The minimum required thickness of the Micore 160 is .312" therefore round up to nearest standard thickness available which is 3/8” (.375”)

Listed Material

Listed Material k (per inch) r (per inch)

.84

K

L

1.19

r

L

Listed Min. Thickness

3/4

"

(.75")

T

L

** Approved Alternate Materials for Floor/Hearth Protection

Alternative Materials Thermal Values

Kaowool M Board

Micore 160™

U.S. Gypsum k (per inch)

K

M

.47

.35

r (per inch) r

M

2.13

2.86

Minimum Thickness

(rounded to nearest 1/8 inch)

Min. Thickness

T

M

.42" (1/2")

.31" (3/8")

Micore 300™

U.S. Gypsum

.46

2.17

.41" (1/2")

1.71" (1-3/4") Durock™ Cement Board

U.S. Gypsum

Hardibacker™

Hardibacker 500™

Cultured Stone Hearthstone™

Wonderboard

Super Firetemp M

Johns-Manville

1.92

1.95

2.30

2.82

3.23

.61

.52

.51

.43

.35

.31

1.64

Super Firetemp L

Johns-Manville

Face brick

Common brick

Cement mortar

Ceramic tile

.54

9.00

5.00

5.00

12.5

1.85

.111

.20

.20

.08

Marble ~11

Table 3 - CANADA REQUIREMENTS

~.09

1.74" (1-3/4")

2.05" (2-1/8")

2.52" (2-5/8")

2.88" (3")

.54" (5/8")

.48" (1/2")

8.04" (8-1/8")

4.46” (4-1/2")

4.46” (4-1/2")

11.16" (11-1/4")

9.82" (9-7/8")

CHIMNEY REqUIREMENTS

This appliance is approved for use in a masonry fireplace built to UBC

Chapter 37 or equivalent with a minimum 26” (660 mm) opening at the front of the fireplace.

These heaters are designed to be installed into an existing masonry fireplace

(built to UBC 37 or ULC S628 standards) or factory-built, solid-fuel and wood-burning fireplaces (listed to UL 127 or ULC S610) only.

Do not remove brick or mortar from masonry fireplace to accommodate insert. Approved with or without positive flue connection. Approved with minimum 6” (152 mm) diameter stainless steel listed reline system.

Country Collection inserts are tested to UL 1482 / ULC S628 and listed by OMNI-Test Laboratories, Inc.; Portland, OR.

IMPORTANT NOTE: See Draft Requirements and Selecting a Proper

Venting System on Page 4 to assist you in choosing the proper venting system for your installation.

Remove and clean behind unit frequently, as creosote build-up may occur rapidly.

INSTALLATION PROCEDURES - MASONRY CHIMNEY

Note: Although not required, a full-length stainless steel liner is recommended for optimum safety and performance. See your Lennox Hearth

Products dealer for details.

Note: When installing your fireplace insert with a positive flue connection, be sure to leave the insulation off the surround panels (flanges) and leave a 1/4” (6 mm) airspace insulation off the surround panels and the facing of your fireplace.

1. READ ENTIRE INSTALLATION INSTRUCTIONS.

2. Check all REqUIRED CLEARANCES as specified in the previous section

(Page 7) of this installation and operation manual.

3. Wear gloves during installation in case of sharp edges on the fireplace insert and it’s parts.

4. Open or remove the existing fireplace damper. Make sure the damper cannot fall closed.

5. Install the two 1/2” x 3” (13 mm x 76 mm) leveling bolts -heads up- a few turns in the leveling nuts on each side of the outer chamber of the insert at the lower rear corners.

6. Position the insert in the center of the fireplace opening and push it back until the surround brackets are approximately 2” (51 mm) away from the fireplace front.

7. Install the side surround panels and push the insert up snug against the fireplace face. Then with the location selected remove the surround panels and level the fireplace insert with the leveling bolts using a 3/4”

(19 mm) socket, extensions (to reach the bolt head) and a ratchet.

8. Glue the insulation around the outer edge of both the top and side surround panels.

9. Install the surround panels loosely, align and tighten. Check for a tight fit against the fireplace.

10. Install the brick and baffle as per instructions on Page 6.

9

POSITIVE FLUE CONNECTION

A positive flue connection is providing a seal between the vent pipe or liner and the existing fireplace chimney for the purpose of preventing room air passage to the chimney cavity of the fireplace. There are different approved methods to achieve this. See Direct Connect Positive

Flue Connection on this page.

When creating a positive flue connection, a positive flue connector ring kit is required (sold separately - see Figure 8). The connector ring kit

(listed below) provides a means to directly attach rigid pipe or a flex pipe adaptor to the flue outlet.

71161 - 6" Positive Flue Connector Ring Kit

Install connector ring kits per instructions provided in kits

Rigid Pipe, Offset Box or

Flex Pipe Adaptor

A full chimney liner is recommended

Must extend starter section past the damper area as a minimum u

Side View of Insert

Fireplace

Chimney

10 u A non-combustible seal is required at the damper area (to prevent dilution air from entering the chimney). See Direct Connect Positive Flue

Connection on this page. A seal-off plate method is shown here.

Figure 9 - Positive Flue Connection

Top of Insert

In Back

Positive Flue

Connector Ring

(sold separately)

Cat. No. H6832, 1/4” to 6-1/4” adjustable

Cat. No. H6833, 6” to 13” adjustable

}

1-1/2”

3-3/4” v

Figure 8 - Connector Ring Kit 2-1/8”

6”

C/L

Direct Connect Positive Flue Connection

Required in Canada

See the following instructions for approved methods of achieving a positive flue connection - See Figure 9.

A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection between the vent pipe or liner and the existing fireplace chimney. The most common method for achieving a positive flue connection in masonry fireplaces is to secure a seal-off plate (i.e. 22-gage sheet steel) in the fireplace throat using masonry screws. Other acceptable methods include packing noncombustible material (i.e. high temp fiberglass or ceramic insulation) around the vent pipe or using a flue adapter. Whatever “seal off” method is used, it must effectively seal the area to prevent room air passage to the chimney cavity of the fireplace.

Offset Boxes

Offsets can be handled using an offset box (it aligns flue outlet of insert with the fireplace flue (see Figure 10). Care should be used to ensure that this adjustable offset box is oriented so it does not angle down when positioned on the insert flue outlet (level or slightly up at the outbound end is recommended).

1-1/2”

C/L w

H6832 - 17”

H6833 - 22”

SIDE VIEW w

6” Dia.

v

6” Dia.

TOP VIEW v Top 6” collar attaches to rigid pipe or flex liner.

w Bottom 6” collar attaches to connector ring on insert flue outlet.

Figure 10 - Offset Box Dimensions

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

5-1/8”

14-1/16”

INSTALLATION PROCEDURE - FACTORY-BUILT ZERO

CLEARANCE FIREPLACES

Fireplace and Chimney Requirements

This appliance must only be installed in a zero clearance factory-built fireplace using 6” (152mm) stainless steel pipe extending from the insert’s flue into the chimney of the fireplace. For optimum safety and

performance we recommend a full length stainless steel liner directly connected to the insert’s flue outlet.

This appliance must only be installed in a zero clearance factory-built fireplace that is structurally sound. Fireboxes or chimneys that have flaws, burnouts, or warping must be replaced or repaired prior to installation.

Check with your fireplace manufacturer if any problems exist.

All convection vents and louvers must be left unmodified and unobstructed.

This appliance can only be installed in the following brands of factorybuilt zero clearance fireplaces: LENNOX, SUPERIOR, HEATILATOR,

MAJESTIC, MARTIN, PREWAY, MARCO, TEMCO and FMI.

The fireplace cavity must be 36” (914 mm) in width, 21” (533 mm) in height and 14” (356 mm) in depth. Installation in larger size fireboxes of the same brands is permissible.

Installations into other brands of the same size is permissible only with approval from local building officials.

Modifications allowed to the factory-built fireplace are as follows:

- Remove the damper

- Remove the smoke shelf or smoke baffle

- Remove ember catches

- Remove viewing screen/curtain

- Remove side and rear bricks

- Remove the fire grate

- Remove doors

The factory built chimney must be listed per UL 127 (US), and meet type

HT requirements of UL 103 (US). Factory built fireplace chimneys tested to UL 127-1998, may be at the fireplace manufacturer’s option, tested to the same criteria as UL 103 HT requirements. If the chimney is not listed as meeting HT requirements, or if the factory built fireplace was tested prior to 1998, a full height listed chimney liner must be installed from the appliance flue collar to the chimney top. The liner must meet type

HT requirements (2100ºF) per UL 1777 (US). The liner must be securely attached to the insert flue collar and the chimney top. To prevent room air passage to the chimney cavity of the fireplace, seal either the damper area around the chimney liner with high temperature sealant or the fireplace front with fiberglass batting.

CLEARANCE TO COMBUSTIBLES

See “Required Clearances” on Page 7.

FIREPLACE PRE-INSTALLATION PREPARATION

NOTE: LENNOX HEARTH PRODUCTS RECOMMENDS PROFES-

SIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER.

SEE YOUR DEALER FOR RECOMMENDATIONS. IMPROPER

INSTALLATION OR MIS-USE WILL VOID YOUR WARRANTY AND

CREATE A SERIOUS SAFETY HAZARD.

Remove any doors or screen materials from the fireplace opening. Remove the damper mechanism completely. Also remove grates or ember catches inside the fireplace hearth. If your fireplace is equipped with a smoke shelf or baffle and if it interferes with the installation it may be removed. Side and rear refractory may also be removed, if necessary, to facilitate installation. No modifications shall be done unless allowed on the previous list. Retain all removed parts, they must be reinstalled before the fireplace can be used in it’s original condition.

INSERT PRE-INSTALLATION PREPARATION

Install the two 3” (76 mm) long bolts (with the head up) through the nuts attached to the insert on the lower rear corner of each side. This will allow you to level the insert when placed into the fireplace.

Measure from the front of the top surround mount to the center of the flue. Determine if there is an alignment problem in connecting a liner from the chimney to the insert’s flue. If there is an alignment problem, connection can be made using a short piece of stainless flex or a stainless steel offset box (available from your dealer). Before installing the liner, make any attachment brackets or drill any holes in the liner, offset box, or insert. Once installed, it may be difficult or impossible to drill additional holes.

FACTORY BUILT FIREPLACE WARNING TAG

The fireplace must not be altered, except for the exceptions listed below. The permanent metal warning label provided must be attached to the back of the fireplace, stating that the fireplace may have been altered to accommodate the insert, and must be returned to original condition for use as a conventional fireplace. The following modifications of factory built fireplaces are permissible: removal of damper, removal of smoke shelf or baffle, removal of ember catches, removal of fire grate, removal of viewing screen/curtain, and removal of doors.

Note: Secure the tag using screws or nails to the fireplace.

WARNING

THIS FIREPLACE HAS BEEN ALTERED TO

ACCOMMODATE A FIREPLACE INSERT AND

SHOULD BE INSPECTED BY A qUALIFIED

PERSON PRIOR TO RE-USE AS A

CONVENTIONAL FIREPLACE.

11

12

CHIMNEY LINER INSTALLATION POST INSTALLATION CHECKS

Remove the existing chimney cap and install a stainless steel liner into the chimney (if a special section has been used or drilled to attach to the insert, it must be the bottom piece). The next piece should be a dripless slip joint, followed by the rest of the chimney liner. Fasten the chimney at the top when it is positioned so that the slip joint will allow the lowest piece to slide up enough to clear the insert during installation. Insulate the top four to six feet between the liner and the chimney to prevent heat loss. Install the cap and flash if necessary to prevent water or creosote from entering the chimney’s venting system.

From inside the fireplace firebox, attach any adaptors or flue offsets and slide the liner up as far as necessary for the bottom piece to clear the insert during installation.

In Canada, This fireplace insert must be installed with a continuous chimney liner of 6” diameter extending from the fireplace insert to the top of the chimney. The chimney liner must conform to the Class 3 requirements of CAN/ULC-S635, Standard for Lining Systems for Existing Masonry or

Factory-Built Chimneys and Vents, or CAN/ULCS640, Standard for Lining

Systems for New Masonry Chimneys.

1. Check that all chimney pipe joints are securely fastened.

2. Be sure all roof flashings are watertight (if applicable).

FOR YOUR OWN PROTECTION AND INSURANCE PURPOSES,

HAVE YOUR CHIMNEY AND CONNECTOR PIPE INSTALLATION

INSPECTED BY YOUR LOCAL BUILDING CODE AUTHORITY OR

FIRE MARSHAL BEFORE STARTING A FIRE IN YOUR STOVE OR

INSERT. NOTIFY YOUR INSURANCE COMPANY.

INSTALLING THE INSERT

Place the insert into the fireplace, making sure to center it side to side.

Slide the insert in until the surround mounts are approximately 1/2” (13 mm) from the face of the fireplace where the surround panels cover.

Lower the chimney and make attachment to the insert. Level the fireplace insert by using a 3/4” socket and a long extension and adjusting the bolts on either side of the insert.

Install the side surround panels with the screws supplied. Push the insert in until there is approximately a 1/4” (6 mm) gap between the back of the surround panels and the face of the fireplace. Before installing the top surround panel, make sure all connections are tight and that no part of the insert or chimney is touching the firebox or chimney in the fireplace.

There must be a minimum of 1” (25mm) clearance between the fireplace insert and the zero clearance fireplace. Install the top surround panel.

If additional support is necessary, factory punched holes in the front corners of the bottom air chamber will accept leveling legs. Carefully measure the distance from the hearth protection to the bottom of the fireplace insert.

Use 3/8” diameter bolts that are 1/2” (13 mm) longer that the distance just measured. Thread a nut onto the the bolt approximately 1” (25 mm). Lift the fireplace insert slightly and insert a bolt into each hole and then thread the nut up the bolt until the front is securely supported. Install another nut onto the bolt through the air space in the fireplace insert and tighten securely. If desired an insert front support, Part# H5296, is available to fill the space between the insert and the hearth protection.

Install the brick and baffle as per Page 6.

OPERATING HINTS STARTING AND MAINTAINING A FIRE

1. Burn only dry, well-seasoned wood for maximum heat output. In some states it is illegal to burn wet wood or anything other than clean, dry wood products.

2. Your fireplace insert is designed to operate with the door closed!

Operate only with the door shut tightly at all times except when loading wood and possibly on start up to establish a draft. Never leave the unit unattended while the front door is slightly opened.

3. DO NOT hit or move the baffle board while loading wood. Occasionally check the baffle. Make sure the baffle blankets are always flush with

4. the front of the baffle boards. Loading oversized logs may dislodge the baffle boards.

CAUTION: THE DRAFT CONTROL MUST BE FULLY OPEN

BEFORE OPENING THE DOOR TO AVOID POSSIBLE COMBUS-

TION FLASH!! (Ignition of hot volatile gases as the door is opened).

5. Feeding excessive amounts of fuel to the fireplace insert should be avoided. It is important to supply it with sufficient draft and fuel to maintain a moderately hot fire. If, during overnight burns, heavy creosote deposits develop inside your fireplace insert and on the door, the draft is set too low - review your burning habits!

CAUTION

Be careful not to abuse door assembly by striking or slamming it. If the door assembly or glass is broken or damaged, they must be replaced with factory original parts before heater can be safely operated. Use only components provided by the manufacturer as replacement parts.

Figure 11

OK

Be sure to clean plated accessories with a household type cleaner and a very soft cloth to remove any fingerprints and residues prior to the first fire.

1. NEVER USE FLAMMABLE LIqUIDS TO START OR REKINDLE

A SOLID FUEL FIRE!!

2. Fully open the primary draft control by pulling the 1” plastic knob out on the left side (lower front corner) until it stops (away from the fireplace insert). This control determines the amount of air entering the fireplace insert. Pushing it toward the fireplace insert reduces the burn rate in the firebox. For your convenience, the rod on this control is marked with four grooves to assist you in obtaining repeatable burn rates.

3. Place a small amount of crumpled paper in front of the firebox and cover it with a few pieces of kindling.

4. Light the paper and allow sufficient time for the kindling to become fully engulfed in flames. You will now close the wood units front door.

(Your wood units front door may or may not need to be left slightly open during this start up process, this depends on the stove model and the amount of draft present. Do not leave the unit unattended while the front door is slightly open) Once kindling is burning well, larger pieces of wood may be added, then the door should be fully closed if there was the need to keep it slightly open during start up.

DO NOT LEAVE THE APPLIANCE UNATTENDED WHILE THE

FRONT DOOR IS SLIGHTLY OPEN.

CAUTION: Do Not alter the adjustment range of the draft control for increased firing for any reason.

Operate only with fuel door and ash drawer closed. Maintain all seals in good condition. Do not operate with broken glass.

Do Not build the fire too close to the glass.

Do not operate the appliance with the door open or ajar other than possibly during start up to create a draft (Do not leave the unit unattended while the front door is slightly open during start up). Operating the appliance with the door open other then in initial start up if needed will produce extreme temperatures within the appliance. Damage caused from over-firing is not covered under the manufacturers limited warranty.

5. For best results, use smaller pieces of wood to get the insert temperature very high before loading larger wood for sustained burns.

If necessary, crack the door to allow ignition of the fuel charge. Do not leave the unit unattended while the front door is slightly open.

Now you can add larger pieces of wood and after several minutes of high burn, set the left control for the desired heat output. Check the exhaust in about 15 to 20 minutes. Large amounts of smoke indicate an improper burn setting (either too high or too low). Adjust and recheck in 5 to 10 minutes.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

13

BLOWER OPERATION

14

Blower Operation

The blower can be operated manually or automatically (blower will turn on when the insert is hot and turn off when the insert is cool).

The rocker switch on the control panel allows you to select between manual operation or automatic operation as follows (see Figure 10):

MANUAL OPERATION: Turn rocker switch to the manual position (up) and adjust rheostat knob to the desired speed. The blower will have to be manually turned “OFF” by rotating the rheostat knob counterclockwise until it clicks.

AUTO OPERATION: Turn rocker switch to the “AUTO” position and the rheostat to the ON position (rotate rheostat knob clockwise until it clicks). When the insert warms up, the blower will automatically turn on (adjust rheostat knob to the desired speed setting). When the insert cools down, the blower will automatically turn off.

Rheostat Operation - The highest blower speed is obtained by turning the rheostat knob clockwise until it clicks “ON”, then rotate towards

“HIGH” to increase blower speed. Rotate the knob clockwise for a lower speed. To turn off, continue to rotate the knob counterclockwise until it clicks “OFF.”

Blower Speed Control

Knob (rheostat)

Figure 11 - Blower Controls

Manual / Auto

Rocker Switch

WARNINGS

The blower must be plugged directly into a properly grounded three-prong receptacle, 120 VAC, 60 Hz, single phase. Do not cut or remove the grounding prong from this plug. Do not route power cord under or in front of appliance.

Blower Operation Guidelines

While in auto operation mode, the blower will turn off and on based on the temperature of the appliance. Auto operation ensures there is sufficient heat build-up to warm the air being moved by the blower before the blower is turned on. Likewise, when the appliance cools off, the blower

Installation must be in accordance with National Electrical Code, ANSI/NFPA 70 - latest edition. In Canada, the current CSA C22-1 Canadian Electrical Code - latest edition.

DANGER: Disconnect power before servicing blower.

is turned off to prevent circulating cool air. Depending on the size and intensity of the fire it may be necessary to adjust the blower speed accordingly to ensure un-interrupted blower operation. For example a small fire may require a slower blower speed to keep the heat output by the blower consistent. If the blower is operated in manual mode, it may be necessary to adjust the blower speed as the fire begins to burn down and

N/O = NORMALLY OPEN the appliance is no longer hot enough to effectively heat the air moved by the blower. If the air coming from the blower feels cool, one should either decrease the blower speed or stoke the fire to build up more heat.

TWO POSITION

SWITCH

MANUAL/TEMPERATURE

YLW

AUTO-RESET

TEMPERATURE

SWITCH N/O

RED

= STUD CONNECTION

WHT RED

BLK RED

POWER CORD

GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED

N/O = NORMALLY OPEN

SPEED

CONTROL/OFF

TWO POSITION

SWITCH

MANUAL/TEMPERATURE

ROOM AIR

BLOWER

= FEMALE DISCONNECT

= MALE DISCONNECT

= STUD CONNECTION

NOTE: SWITCH CONDITIONS YLW

GIVEN AT ROOM TEMPERATURE

WHT N/C = NORMALLY CLOSED

N/O = NORMALLY OPEN

Figure 12 - Blower Wiring Schematic BLK

= FEMALE DISCONNECT

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

POWER CORD

= MALE DISCONNECT

= STUD CONNECTION

GRN

WHT

AUTO-RESET

TEMPERATURE

SWITCH N/O

RED

TWO POSITION

RED SWITCH

MANUAL/TEMPERATURE

RED

SPEED

CONTROL/OFF

POWER CORD

GRN

BLK ROOM AIR

BLOWER

YLW

SPEED

CONTROL/OFF

AUTO-RESET

TEMPERATURE

SWITCH N/O

RED

RED

RED

ROOM AIR

BLOWER

OPERATING TECHNIqUES AND HINTS

Recent developments in wood-burning technology have made wood-burning a cleaner and more convenient way to heat your home. Overall efficiency in a wood-burning appliance is a combination of combustion efficiency and heat transfer efficiency. Whether heating your entire home or just a room or two, your understanding of how to best operate your stove or insert will enhance its overall efficiency and performance. What this can mean to you is longer, cleaner burns, less wood use and more heat.

GETTING THE MOST OUT OF YOUR FIREPLACE INSERT

The following sections will outline techniques you can use to “get the most out of your fireplace insert.” Please read them carefully.

MAXIMIZING YOUR FIREPLACE INSERT’S OVERALL

EFFICIENCY

It is important to know that for high, combustion efficient, clean burns, you will need to have sufficient temperatures inside the firebox for

thorough combustion. The best method for determining if you have sufficient temperatures is to watch the brick lining in your firebox. When you first light your fireplace insert, the bricks will turn a dark brown or black. After 20 to 30 minutes of a hot fire, most of the bricks should return to near their original light brown or yellow color. This means the bricks have reached a high enough temperature for your fireplace insert to achieve high combustion efficiency.

Second and just as important, is achieving a high level of heat transfer

efficiency. Slowing the rate of flow through the stove or insert enhances heat transfer, thus allowing more time for heat to be transferred into your home. To do this, be sure to thoroughly preheat your fireplace insert and then reduce the amount of primary air by closing the draft control (lower left) to about 1/2 to 3/4 open. This will decrease the excess oxygen in your flue, which carries heat up your chimney, but should still be enough air to allow the fireplace insert to produce its maximum heat output.

(More air may produce a lightly greater amount of heat, but will greatly increase wood consumption). When the area being heated reaches a comfortable temperature, slow the burn rate by closing the control to further improve heat transfer.

To get the most out of your fireplace insert, you will need to combine good combustion efficiency with good heat transfer practices. The following are some tips on how to operate your fireplace insert to achieve the highest overall efficiency.

1. Thoroughly preheat your fireplace insert before slowing the burn rate by closing the draft control.

2. Measure the fireplace insert temperature at the hottest point on the fireplace insert top or face. Use this information to repeat burn rates.

3. Once preheated, add wood (if needed) and partially close the draft control (lower left).

4. Operate your fireplace insert as much as possible in the low to medium burn ranges.

5. Do not lower the draft setting so low as to completely extinguish the flames in the firebox. Check for at least some small flames 20 minutes after setting the draft control.

6. Do not continually operate your fireplace insert in the high (wide open) setting. This wastes wood by carrying a great deal of heat up the chimney and can damage your fireplace insert and chimney.

7. Go outside and check your chimney. More than a very small amount of smoke indicates wasted heat, creosote build up and pollution.

ACHIEVING CLEAN, LONG BURNS

To achieve long burn times, after having thoroughly preheated the fireplace insert, let the fireplace insert top cool down to 275 to 400 degrees (on Elites, locate thermometer on the face of the insert just

above the door). Now load the firebox and set the draft control. At this point, you may need to burn the fireplace insert with the draft open for a few minutes to ignite the wood. All Lennox Hearth Products stoves and inserts are EPA tested for emissions at low burn with the air control completely closed. Whether or not you should burn your fireplace insert with the air control completely closed will depend on the following factors:

• How you load your wood

• Your chimney type, height and draft

• Your wood type and its moisture content

• The temperature of the fireplace insert

• Which model stove or insert you have

Experiment with different loading configurations to achieve longer burns.

Try loading the wood from side to side and nesting it in the ashes to prevent airflow under and around the wood. Fresh wood should be loaded to the back of the firebox or to the sides. Hot coals or half burned wood should be brought toward the front of the firebox. The way you load your wood can seriously affect burn times. If the new load does not ignite within a few minutes, try crisscrossing the load to allow more airflow around the fire, or try a slightly hotter fireplace insert temperature.

Determining the lowest setting for efficient low burns. This will require some experimentation on your part. Try closing the air control all the way with the fireplace insert temperature at 325 to 350 degrees. If the flames are completely extinguished, open the air control halfway and then slowly close it until there is only a small amount of flame. It is important to check the fireplace insert about 20 minutes after setting the draft control as it takes this long for the fireplace insert temperature to stabilize. There should still be some small flames on or above the wood load.

Use 325 degrees as a starting point. You can try starting temperatures

25 degrees higher or lower to achieve desired burn times, start 25 degrees lower if the fireplace insert burns the wood too quickly or 25 degrees higher if there are no flames in the firebox for more than a few minutes after loading the wood. You may or may not need to burn the fireplace insert with the air control open for a few minutes prior to setting the draft for a low burn, this will depend on the factors mentioned above. Be sure not to smolder a fire overnight. Check your chimney for large amounts of smoke as this indicates very poor combustion.

It is important to realize that stove technology has changed. Stoves and fireplace inserts have changed a great deal in the last few years. This has led to substantial changes in the methods of operation in new stoves as compared to older stoves. In old stoves without full brick linings and ceramic insulation, the rule was “get the stove as hot as possible before setting the draft on low for overnight burns.” On newer, high technology

Lennox Hearth Products stoves, this is not necessary. Although it is still important to have the stove hot enough to burn efficiently, it will require less preheating. Once you have determined your optimum operating temperatures for various burn rates, we believe you will find your stove or fireplace insert an extremely convenient way to achieve your heating needs.

Do not reload the fireplace insert for long burns when the stainless secondary tubes or baffles are glowing red, or when the fireplace

insert is uncomfortably hot to load. This indicates the fireplace insert is too hot to load for a long burn. Also, do not load wood for a long burn on a deep bed of hot coals. Try stirring the coals a few minutes before loading the fireplace insert for a low burn to allow some of the unburned coals time to burn.

15

16

MAINTENANCE

DOOR HINGES: If door hinges need lubricating, use an anti-seize compound (never use oil) available from your Lennox Hearth Products dealer.

DOOR LATCH: If your door latch fails to latch tightly and the gasket is in good condition, place a length of pipe (cheater bar) over the inside portion of the door handle and bend slightly toward the door until the proper adjustment is obtained. If the door handle does not close easily, apply high temperature anti-seize to the striker.

DOOR GASKET: Periodically check gasket to make sure it is not overcompressed. If compressed, replace with a special woven door rope.

(Don’t try substituting rope, only use special Lennox Hearth Products door rope).

PLATED ACCESSORIES: Clean only with a household type glass cleaner and a very soft cotton cloth Other products may damage plated finish, paint and gaskets.

BAFFLE BLANKETS: Your baffle blankets should be inspected during every chimney cleaning. If the blanket is compressed or heavily stained, it should be replaced. Heavy creosote stains or matting is an indication of improper use and your burning habits should be reviewed.

GLASS CLEANING: Only clean glass with products specifically made to use on wood stoves and fireplace inserts. Other products could damage gaskets and paint. Never scrape glass with a razor blade. This can pit the glass and make it impossible to clean in the future.

WINDOW GASKET: The window gasket can be checked by running the flame of the match near the gasket and around the door. If the flame is drawn in around the window, the gasket should be replaced.

DOOR HANDLE: Door handle may become tight as you use the fireplace insert. Free the handle up by using dry graphite supplied with the fireplace insert. The directions are included with the graphite.

WARNINGS

Inspect and clean chimney and connector frequently.

Under certain conditions of use, creosote buildup

may occur rapidly. See Installing the Insert on Page

12 for instructions on removing the appliance for cleaning (reverse order of instructions).

GLASS CLEANING GUIDELINES

WARNING: DO NOT CLEAN GLASS WHEN APPLIANCE IS HOT!

Glass on any wood stove or fireplace insert will not stay perfectly clean.

Here are some guidelines for cleaning and caring for the glass:

• Ensure the stove or fireplace insert is cold prior to cleaning glass.

• This appliance is designed to provide a flow of air over the inside of the glass, where along with high heat helps inhibit build-up on the glass. When build-up occurs, a commercial glass cleaner designed for stoves is recommended. Regular household glass cleaners will not clean creosote.

• Do not use abrasives such as steel pads, steel wool or oven cleaner as they will scratch the glass. Never scrape glass with a razor blade as this may pit the glass and make it impossible to clean in the future.

• Do not use chemical glass cleaners as they may damage the gaskets or painted surfaces.

TIPS FOR KEEPING THE GLASS CLEAN

• Burn only dry seasoned cord wood. Wet wood = Dirty glass.

• A short, hot fire (15 - 20 minutes) may help to clean off some of the normal buildup. Lower burns = more build-up. Higher burns = less build-up.

• Keep freshly loaded wood away from the glass.

• After reloading, allow all the wood to catch flame before dampering down the stove or fireplace insert.

CAUTION

Cleaning Glass: Ensure appliance is cold prior to cleaning glass. A commercial glass cleaner designed for stoves is recommended. Do not use abrasive cleaners. Do not clean with any materials, which may scratch or otherwise damage the glass.

Scratches on the glass can develop into cracks or break. Inspect the glass regularly. If you detect a crack, extinguish the fire and contact your dealer for a replacement.

GLASS REPLACEMENT INSTRUCTIONS

Step 1. Remove Door Assembly - Open door to remove E clip from the upper hinge pin. Remove upper hinge pin by pulling up while holding the opposite side of the door. Lift door out of the lower hinge pin and place face down on a soft surface.

Step 2. Remove Door Back Screws (6 ea.) - Using a 5/32” allen wrench remove the 6 retainer screws from the faceplate. To locate screws, peel back the door gasket as necessary.

Step 3. Disassemble Door Assembly - Flip door assembly over to be face up.

Separate faceplate from door back by pulling up on faceplate.

Step 4. Remove Glass - Carefully remove broken glass one piece at a time

(protective gloves are recommended)

Step 5. Install New Glass Assembly - Install the new glass with gasket in recess on door back (use only factory supplied 5mm ceramic glass. Do not substitute).

Step 6. Reinstall Faceplate and Screws - Reinstall faceplate onto door back and while holding the door assembly together flip the assembly back onto it’s face. Carefully reinstall the screws. Be very careful not to overtighten the screws (this could result in glass breakage when the stove or fireplace insert is hot) and it is highly recommended to use anti seize on the screws.

Step 7. Reinstall Door - Set door assembly back into the lower hinge mount while holding the handle side of the door up. Place the upper hinge pin back in the mount and door assembly. Reinstall the E clip that was removed.

Door Gasket

Door Back

Glass

Figure 20

Faceplate

Handle Rod

Glass Gasket

DIRTY GLASS:

SMOKES WHEN

DOOR IS OPEN:

WOOD BURNS

TOO FAST:

POOR HEAT

OUTPUT:

PAINT GIVES OFF

ODOR (smoke):

TROUBLESHOOTING

Problem

POOR DRAFT:

EXCESSIVE DRAFT:

Solution

Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the fireplace inserts’ draft depend solely on the natural draft of the chimney (See Draft Requirements on Page 4). If your fireplace insert is not drafting properly, your chimney is the problem. All stoves and fireplace inserts are thoroughly tested to ensure proper draft with the correct size chimney flue.

With better chimneys being more common, excessive draft can be an issue. Alleviate excessive draft by slowing the burn rate of the fireplace insert once it has reached proper operating temperature (See Maximizing Your Fireplace inserts Overall Efficiency on Page 15).

1) Burn smaller, hotter fires and check to make sure you are not setting the draft down too far with the draft control.

2) Make sure your wood is well seasoned and dry (not open to rain - see Creosote and Fuel sections on Page 5).

3) See Poor Draft section (above) and Clean Glass (above).

1) If smoke is entering the room, check to make sure your baffle boards are properly installed

and that the baffle blankets are pushed back flush with the front of the baffle boards.

2) Check the chimney for blockage due to creosote (see Creosote section on Page 5).

3) Check draft (See POOR DRAFT section above).

1) The draft control must be closed further.

2) Add fuel at lower firebox temperatures.

3) Load wood side to side and reduce the flow of air under wood.

4) The door seal may need replacing, check for leakage.

5) See “Excessive Draft.”

1) Check your wood. Wet, moist, unseasoned wood will not produce heat.

2) Your fireplace insert needs to be seasoned (moisture removed from the steel and brick). Continue to burn a fire. It normally takes from one to three weeks of burning to season your fireplace insert (See Burn-In Period on Page 5).

3) See Excessive Draft section above.

Paint is tempering-in. Burn only moderately hot for the first few days until paint is fully cured.

Then burn a very hot fire to cure any paint that may not easily cure. Open windows or door to ventilate (See Burn-In

Period on Page 5).

17

18

DO’S AND DON’T

DO NOT: Install or operate this fireplace insert before reading this manual.

DO NOT: Close the draft beyond the point at which the flames are completely extinguished.

DO NOT: Open the fireplace insert door without fully opening the draft first.

DO NOT: Burn driftwood or wood that has been in salt water. This includes some mill ends and scrap lumber that has been floated in salt water on the way to the mill. (This will void your warranty).

DO NOT: Handle the plated faceplate unnecessarily. Use the door handle only.

DO NOT: Force oversized logs into the firebox as this may dislodge the baffle assembly.

DO NOT: Close the door tightly during Burn-In period.

DO:

DO:

DO:

DO:

DO:

DO:

DO:

Be sure to clean any fingerprints from the Gold or Nickel faceplate before burning the fireplace insert. Clean the Gold or Nickel door only with a household type glass cleaner and a very soft cloth.

Consult local building department if other than recommended clearances are desired.

Read instructions for the baffle boards and baffle blankets occasionally to ensure you have not bumped or moved them out of place when loading wood.

Check the chimney and baffle monthly to make sure they are clean.

Burn seasoned, dry wood only! (RAIN = WET WOOD)

Open the door frequently during Burn-In period to keep gasket from adhering to the curing paint.

Enjoy the warm feeling of your new Lennox Hearth Products appliance.

REPLACEMENT PARTS - MODELS C210, CA210 AND SWI210

Contact an Lennox Hearth Products dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards.

Item # Cat. No.

6

7

4

5

8

1

2

3

9

10

11

12

13

14

FRONT DOOR PARTS LIST

Description

H5639 Door Rope Kit, 7/8” Dia. (6’ 2”)

H5629 Upper Hinge Pin

H5626 Upper Hinge Pin E-Clip

H5628 Lower Hinge Pin

H5646 Lower Hinge Pin Copper Washer

H5640 Glass Gasket Kit (8’ 4”)

H5577 Set of 6 screws and 6 washers for door assembly

H5654 Spring Handle / Nickel

H5653 Spring Handle / Gold

71067 Traditional Door Glass / Plain

71068 Traditional Door Glass / Sailboat

71063 Traditional Door Glass / Cattail

71065 Traditional Door Glass / Evergreen

71066 Traditional Door Glass / Floral

71057 Traditional Door Faceplate / Black

71058 Traditional Door Faceplate / Gold

71059 Traditional Door Faceplate / Nickel

71148 Traditional Door Faceplate / Brushed Gold

71145 Traditional Door Faceplate / Brushed Nickel

71072 Arch Door Glass / Plain

71073 Arch Door Glass / Sailboat

71069 Arch Door Glass / Cattail

71070 Arch Door Glass / Evergreen

71071 Arch Door Glass / Floral

71060 Arch Door Faceplate / Black

71061 Arch Door Faceplate / Gold

71062 Arch Door Faceplate / Nickel

71147 Arch Door Faceplate / Brushed Gold

71144 Arch Door Faceplate / Brushed Nickel

H5579 Traditional Door Back w/ Handle (door gasket included)

H5578 Arch Door Back w/ Handle (door gasket included)

46

47

39

40

41

42

43

35

36

37

38

44

45

15

16

17

18

19

29

32

33

34

USB BLOWER PARTS

H8067 UHPII Wiring Harness

H5655 UHPI & UHPII Blower Speed Control

H8068 Snap Switch Bracket w/ hardware

H8082 Replacement Power Cord

H8074 UHPII Blower Cage-Snap Switch/ Black

H8075 UHPII Blower Cage-Snap Switch/ Gold

H8076 UHPII Blower Cage-Snap Switch/ Nickel

H8077 UHPII Blower Cage-Snap Switch/ Brushed Gold

H8078 UHPII Blower Cage-Snap Switch/ Brushed Nickel

H8064 Snap Switch w/ Gasket and Hardware

H8066 Control Switch (Manual, Off, Automatic)

C/A210 AND SWI210 INSERT PARTS

71139 Large Flange Screw/ Black - Seven Needed

H5294 Large Flange Screw/ Gold - Seven Needed

H5295 Large Flange Screw/ Nickel - Seven Needed

H8079 C/A210 Nameplate Kit w/ Hardware - Nickel

(1 ea. Lennox & 1 ea. Country)

H8080 C/A210 Nameplate Kit w/ Hardware - Gold

(1 ea. Lennox & 1 ea. Country)

H5650 Draft Rod Knob

H5645 Side Leveling Bolts - Two Included

H5644 Blower Mounting Bolts - Two Needed

H5612 Firebrick 4-1/2” x 9” (14 per stove)

H5606 Firebrick 4-1/2” x 5-1/2” (4 per stove)

H5605 Firebrick 3” x 9” (2 per stove)

H5611 Firebrick 2-1/8” x 9” (2 per stove)

H5599 Firebrick 1-1/2” x 9” (2 per stove)

H3096 Firebrick 1-1/2” x 5-1/2” (1 per stove)

H5603 Firebrick 1-1/2” x 3” (1 per stove)

H5571 Complete Baffle/Secondary Burn Tube Assembly

(includes tubes and all mounting hardware)

H8019 Baffle Blankets 15-1/4” x 12-1/2” x 1” - Two

Included

H8018 Baffle Board Kit w/ Baffle Blankets

MISCELLANEOUS PARTS

71052 Dry Graphite (Apply to door handle and door hinges)

H5633 Anti Seize 2 gram pouch

19

20

REPLACEMENT PARTS - MODELS C210, CA210 AND SWI210

47

33

46

34

45

36

36

35

38

38

38

41

40

37

37

44

40

38

38

42

38

38

38

42

38

38

38

38

41

38

38

39

39

43

39

39

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

REPLACEMENT PARTS - MODELS C210, CA210 AND SWI210

Door Parts

1

1

3

2

14

5

4

2

3

8

13

5

4

9

8

6

7

10

Blower Parts

11

6

12

15

17

29

16

32

19

7

18

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

21

22

ACCESSORIES - MODELS C210, CA210 AND SWI210

Cat. No.

H7891

H7892

H8403

Product Reference Information

Description Ship.

Weight

427 lb.

C210T-B, Insert / Traditional Black Door /

Nickel Nameplate

C210A-B, Insert / Arch Black Door / Nickel

Nameplate

SWI210, Insert / Traditional Black Door

426 lb.

427 lb.

Ship.

Volume

18.30 cu. ft.

18.35 cu. ft.

18.30 cu. ft.

71012

71074

71075

71078

71079

71025

71026

71007

71008

71011

Cat. No.

71038

71033

71039

71034

71040

71033

71041

71034

SURROUND PANELS / TOP AND SIDES (REqUIRED)

Model Description

WFPT0740-L

WFPS0718

26-1/2” x 40”:

Top Surround 7-1/2” x 40”

Side Surrounds 7-1/2” x 18-3/4”

WFPT0748-L

WFPS1118

26-1/2” x 48”:

Top Surround 7-1/2” x 48”

Side Surrounds 11-1/2” x 18-3/4”

30-1/2” x 40”:

Top Surround 11-1/2” x 40” WFPT1140-L

WFPS0718

WFPT1148-L

WFPS1118

Side Surrounds 7-1/2” x 18-3/4”

30-1/2” x 48”:

Top Surround 11-1/2” x 48”

Side Surrounds 11-1/2” x 18-3/4”

FACEPLATE KITS

H7901

H7902

H7904

H7905

ARCH-FPK-BG Arch Faceplate, Brushed Gold

TRAD-FPK-BG-SM Traditional Faceplate, Brushed Gold

ARCH-FPK-G Arch Faceplate, Gold

TRAD-FPK-G-SM Traditional Faceplate, Gold

SURROUND TRIM - THESE ARE NOT REqUIRED BUT AN OPTION

71021 WFT2640-B Black 26-3/4” x 40”

71022 WFT2648-B Black 26-3/4” x 48”

WFT3040-B

WFT3048-B

WFT2640-G

WFT2648-G

WFT3040-G

WFT3048-G

WFT2640-N

WFT2648-N

WFT3040-N

WFT2948-N

Black 30-3/4” x 40”

Black 30-3/4” x 48”

Gold 26-3/4” x 40”

Gold 26-3/4” x 48”

Gold 30-3/4” x 40”

Gold 30-3/4” x 48”

Nickel 26-3/4” x 40”

Nickel 26-3/4” x 48”

Nickel 30-3/4” x 40”

Nickel 30-3/4” x 48”

71053

71054

H8159

H5296

H6832

H6833

71161

Cat. No.

H7907

H7908

H7909

H7910

H7911

BLOWERS

Model

WSINS-BLWR-B-SS

WSINS-BLWR-G-SS

Description

Blower Insert Black

Blower Insert Gold

WSINS-BLWR-N-SS Blower Insert Nickle

WSINS-BLWR-BN-SS Blower Insert Br-nkl

WSINS-BLWR-BG-SS Blower Insert Br-gold

MISC. PARTS

Paint Gold (1/2 Pint) Paint Gold (1/2 pint)

Paint Nickel (1/2 Pint) Paint Nickel (1/2 pint)

TSPK-B Touch-Up Paint , Metallic Black, 12 oz. Aerosol

FRNT-SPPT Front Support 40”- 48” Width / 8”-

0” Height

(ref. form #775305M)

OFFADJFLUEBX6SM Adjustable Offset Flue Box, 6” Flue to 6” Exhaust (0-6”)

OFFADJFLUEBX6LG Adjustable Offset Flue Box, 6” Flue to 6” Exhaust (6-12”)

WINS-6FC 6” Positive Flue Connector Ring Kit

(ref. form #775232M)

SAFETY / LISTING LABEL - MODELS C210, CA210 AND SWI210

2011 2012 2013

23

WARRANTY

Your wood appliance is covered by a limited warranty (provided with the appliance). Please read the warranty to be familiar with its coverage.

Retain this manual. File it with your other documents for future reference.

REPLACEMENT PARTS

See Page 19 for a complete replacement parts list. Use only parts supplied from the manufacturer.

Normally, all parts should be ordered through your Lennox distributor or dealer. Parts will be shipped at prevailing prices at time of order.

When ordering repair parts, always give the following information:

1. The model number of the appliance.

2. The serial number of the appliance.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the appliance.

If you encounter any problems or have any questions concerning the installation or application of this system, please contact your dealer.

LENNOX HEARTH PRODUCTS

1508 Elm Hill Pike, Suite 108

Nashville, TN 37210 visit us at www.Lennox.com

1-800-9-LENNOX

PRODUCT REFERENCE INFORMATION

We recommend that you record the following important information about your appliance. If you did not purchase your appliance directly from a

Lennox Hearth Products dealer, then please call 1-800-9-LENNOX for the name and phone number of your nearest Lennox Hearth Products dealer who will answer your questions or address your concerns.

Your Appliance’s Model Number _______________________________________

Your Appliance’s Serial Number ________________________________________

The Date On Which Your Appliance Was Installed __________________________

Your Dealer's Name _________________________________________________

Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Consult your local distributor for fireplace code information.

24

Printed in U.S.A. © 2007 by Lennox Hearth Products

P/N 775212M Rev. C 09/2011 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement