Black Box LB9804A manual


Add to My manuals
20 Pages

advertisement

Black Box LB9804A manual | Manualzz

OCTOBER 1997

LB9801A

LB9802A

LB9803A

LB9804A

Two-Port 10/100 Ethernet Switches

Dual 10/100 UTP Port

10/100 UTP Port with (1) 100BASE-FX Port

H/F

H/F

10/100

A/M

Two Port 10/100 Ethernet Switch

2

COL/FD

100

LINK

RX

TX

1

RX

RX

LINK

COL/FD

1

RX

LINK

COL/FD

100

H/F

10/100

A/M

Two Port 10/100 Ethernet Switch

2

COL/FD

100

LINK

RX

H/F

10/100

A/M

CUSTOMER

SUPPORT

INFORMATION

Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)

FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746

Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018

Web site: www.blackbox.com • E-mail: [email protected]

FCC STATEMENT

FEDERAL COMMUNICATIONS COMMISSION

AND

INDUSTRY CANADA

RADIO FREQUENCY INTERFERENCE STATEMENTS

This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference.

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.

1

TWO-PORT 10/100 ETHERNET SWITCHES

NORMAS OFICIALES MEXICANAS (NOM)

ELECTRICAL SAFETY STATEMENT

INSTRUCCIONES DE SEGURIDAD

1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.

2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.

3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.

4. Todas las instrucciones de operación y uso deben ser seguidas.

5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc..

6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante.

7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante.

8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado.

9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación.

10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor.

11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato.

2

NOM STATEMENT

12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada.

13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato.

14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante.

15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia.

16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo.

17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación.

18. Servicio por personal calificado deberá ser provisto cuando:

A: El cable de poder o el contacto ha sido dañado; u

B: Objectos han caído o líquido ha sido derramado dentro del aparato; o

C: El aparato ha sido expuesto a la lluvia; o

D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o

E: El aparato ha sido tirado o su cubierta ha sido dañada.

3

TWO-PORT 10/100 ETHERNET SWITCHES

TRADEMARKS USED IN THIS MANUAL

UL is a registered trademark of Underwriters Laboratories Incorporated.

Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.

4

CE MARK

CE MARK

The CE mark symbolizes compliance with the European Community’s EMC directive. The Two-Port 10/100 Ethernet Switches meet or exceed these technical standards:

• EN 55022 — “Limits and Methods of Measurement of Radio

Interference Characteristics of Information

Technology Equipment”

• EN 50082-1 — “Electromagnetic compatibility—Generic immunity standard Part 1: Residential, commercial and light industry”

• IEC 801-2 — “Electromagnetic compatibility for industrial-process measurement and control equipment Part 2:

Electrostatic discharge requirements”—Severity level 3

• IEC 801-3 — “Electromagnetic compatibility for industrial-process measurement and control equipment Part 3: Radiated electromagnetic field requirements”—Severity level 2

• IEC 801-4 — “Electromagnetic compatibility for industrial-process measurement and control equipment Part 4: Electrical fast transient/burst requirements”—Severity level 2

• CISPR 22 — Radiated and Line-conducted Class A

• EN 60950 — ITE Safety

5

TWO-PORT 10/100 ETHERNET SWITCHES

Contents

Chapter Page

1. Specifications ..................................................................................................7

2. Introduction....................................................................................................9

2.1 Description............................................................................................9

2.2 Features ................................................................................................9

3. Applications ..................................................................................................10

4. Installation and Setup ..................................................................................11

4.1 Front Panels ........................................................................................11

4.2 LEDs ....................................................................................................12

4.3 DIP Switches........................................................................................12

4.4 Copper Port ........................................................................................13

4.5 Fiber Port ............................................................................................14

5. Troubleshooting ..........................................................................................15

5.1 Problems..............................................................................................15

5.2 Calling Black Box................................................................................16

5.3 Shipping and Packaging ....................................................................16

6

Speed —

Duplex Support —

Compatibility —

Connectors —

Diagnostics —

Mounting —

Operating Temperature —

Storage Temperature —

Humidity —

Power —

Size —

Weight —

CHAPTER 1: Specifications

1. Specifications

Standards Compliance —

10/100 Mbps

Half and full

IEEE 802.3; IEEE 802.3u (Fast Ethernet standard)

LB9801A: (2) RJ-45 10/100 autosensing;

LB9802A: (1) RJ-45 10/100 autosensing,

(1) fiber for multimode; LB9803A–04A:

(1) RJ-45 10/100 autosensing, (1) fiber for single mode

LINK (Green): ON when another 10BASE-

T hub or NIC is connected to the port;

RX (Green): ON indicates receive data from a connected hub or NIC card;

COL/FD: Yellow, port is in a collision state; Green, port is configured for fullduplex communication; 100 (UTP)

[Green]: ON indicates port configured for

100 Mbps

UL ® 1950; CSA 22.2 No 950; VCCI;

FCC Part 15, Class A; CE EN 60950

19" rack mounting for up to 2 units

32 to 104°F (0 to 40°C)

14 to 122°F (-10 to +50°C)

Up to 85% maximum, noncondensing

100–240 VAC, 50–60 Hz, 1 amp maximum at 220V

1.8"H x 8"W x 10"D (4.6 x 20.3 x 25.4 cm)

2.3 lb. (1 kg)

7

TWO-PORT 10/100 ETHERNET SWITCHES

Optical —

Distances (km)

Fiber Mode

Fiber Attenuation (dB)

Output Power Range (dBm)

Receiver Sensitivity (dBm)

Receiver Saturation (dBm)

Optical Power Budget (dB)

LB9802A

0 to 2

MM

3

-19 to -14

-30

-14

11 to 16

LB9803A

0 to 18

SM

0.4

-19 to -14

-30

-14

11 to 16

LB9804A

17 to 40

SM

0.4

-10 to -7

-30

-14

20 to 23

8

2. Introduction

CHAPTER 2: Introduction

2.1 Description

The Two-Port 10/100 Ethernet Switches are standalone, dual-port Ethernetto-Fast-Ethernet switches. In addition to enabling 10/100-Mbps and 100/100-

Mbps switching, the Switches can also extend the diameter of Fast Ethernet networks up to 100 km.

The Two-Port 10/100 Ethernet Switch is available in both a UTP and a fiberoptic version. Each copper port on the Two-Port 10/100 Ethernet Switch offers IEEE standard NWay auto-negotiation and is configurable for either half-duplex (for a 100-Mbps shared connection) or full-duplex (for a 200-

Mbps point-to-point collision-free connection). Each fiber port is configurable for only a 100-Mbps half-/full-duplex connection.

The Two-Port 10/100 Ethernet Switch uses self-learning of network addresses, and filters local traffic, collisions and error packets.

2.2 Features

• Complies with IEEE 802.3 and IEEE 802.3u standards.

• Uses UTP, multimode, or single-mode DSC connectors.

• Up to 110 km over single-mode fiber.

• Full-/half-duplex operation on all ports and speeds.

• NWay auto-negotiation for automatic speed and duplex configuration

(UTP only).

• Plug-and-play installation and support for all network operating systems and protocols.

• Status LEDs indicate switch operations for easy maintenance.

9

TWO-PORT 10/100 ETHERNET SWITCHES

3. Applications

Figures 3-1 and 3-2 illustrate some of the Switch’s application possibilities.

Connections can include 10-Mbps and 100-Mbps servers, a Fast Ethernet backbone, 10/100-Mbps hubs or individual stations, all functioning in half-

/full-duplex mode. The medium can be either 10BASE-T/100BASE-TX UTP or 100BASE-FX fiber. The various fiber modules offer distance extensions in a 2-km to 110-km range (1.2 to 68.4 miles).

LB9801A

10 Mbps 100 Mbps

Half-Duplex

100-Mbps Switch

10-Mbps Hub

10-Mbps Workstations 100-Mbps Workstations

Figure 3-1. LB9801A.

LB9802A, LB9803A, or

LB9804A

100 Mbps

Half-Duplex

200 Mbps up to 200 km

Full-Duplex

10-Mbps Switch with fiber uplink port

100-Mbps Hub

10-Mbps Workstations 100-Mbps Workstations

Figure 3-2. LB9802A, LB9803A, or LB9804A.

10

CHAPTER 4: Installation and Setup

4. Installation and Setup

Two-Port 10/100 Ethernet Switches are standalone units designed for 19" rack mounting. LED indicators help with installation and maintenance.

Figures 4-1 and 4-2 show the front panels of the different models.

4.1 Front Panels

3 2 1

1 2

Figure 4-1. Front panel—LB9801A.

6 5 4

H/F

TX

1

RX

RX LINK COL/FD

3 2

2

1

Figure 4-2. Front panel—LB9802A, LB9803A, and LB9804A.

11

TWO-PORT 10/100 ETHERNET SWITCHES

4.2 LEDs

Group 1 Right of UTP port (2); 10/100BASE-TX port LEDs

RX Data is being received from a connected hub or NIC card.

LINK Indicates connection to another switch, a hub, or a NIC.

COL/FD Bi-color LED. Yellow: port is in collision state. Green: port is configured for full-duplex communication.

100 Port is configured for 100 Mbps (UTP connection only).

Group 4 Right of fiberoptic port (5); 100BASE-FX port LEDs

These LEDs have the same functions as the Group 1 LEDs with the same names.

4.3 DIP Switches

The DIP switches change port configuration only during power-up.

In order to work in a fixed-rate mode, A/M (auto-negotiation/manual) must be set to UP. Then set H/F (Duplex) and 10/100 (Rate) to 10 half-, 10 full-,

100 half-, or 100 full-duplex modes.

To work in auto-negotiation mode, A/M must be set to DOWN. Then H/F can be set to the desired duplex mode (half/full).

12

CHAPTER 4: Installation and Setup

4.4 Copper Port

H/F 10/100 A/M

Figure 4-3. Copper port default configuration:

100 half-duplex mode.

Group 3

UP

DOWN

H/F

Duplex

Full

Half

10/100 A/M

Rate Auto/Manual

100 Manual

10 AutoNeg

13

TWO-PORT 10/100 ETHERNET SWITCHES

4.5 Fiber Port

H/F

Figure 4-4. Fiber port default configuration:

100 half-duplex mode.

Group 6

UP

DOWN

H/F

Duplex

Full

Half

WARNING

Activating both auto-negotiation and full-duplex modes of operation is not defined by the IEEE 802.3u standard and may lead to unpredictable results.

14

CHAPTER 5: Troubleshooting

5. Troubleshooting

The Two-Port 10/100 Ethernet Switches are highly reliable. However, if a problem occurs, follow the steps below.

5.1 Problems

1) Symptom: None of the LEDs light or blink.

Cause:

Action:

The Switch isn’t getting power or isn’t working properly.

First, make sure the power cord is plugged in firmly.

Make sure the outlet works. If the cord and outlet are fine, call Black Box about getting a replacement Switch.

2) Symptom: The LINK LED does not light when…

Copper Port a) …the port is configured through DIP switches for 10 Mbps, no auto-negotiation, with a connection to a 10-Mbps PC adapter.

b) …the port is configured through DIP switches for 100 Mbps, no auto-negotiation, with a connection to a 100-Mbps PC adapter.

Cause:

Action: c) …the port is configured through DIP switches for 10 Mbps, no auto-negotiation, with a connection to a 10-Mbps hub.

d) …the port is configured through DIP switches for 100 Mbps, no auto-negotiation, with a connection to a 100-Mbps hub.

For a) and b), cable is not crossed or not connected securely.

For c) and d), cable is crossed or not connected securely.

Check cable connections in all four cases.

Fiber Port

…the Two-Port 10/100 Ethernet Switch’s port is connected to the fiberoptic port of any 100-Mbps hub or switch.

Cause:

Action: a) Fiberoptic cable is not connected securely.

b) The Two-Port 10/100 Ethernet Switch is defective.

a) Check cable connections.

b) Replace the Two-Port 10/100 Ethernet Switch.

3) Symptom: Copper port is configured through DIP switches to

100 Mbps, half-/full-duplex; 100 LED does not light.

Cause:

Action:

LED isn’t working properly.

Call Black Box about getting a replacement Switch.

15

TWO-PORT 10/100 ETHERNET SWITCHES

4) Symptom: COL/FD LED does not light Green when the copper/fiber port is configured through DIP switches to full-duplex

(with/without auto-negotiation).

Cause:

Action:

LED isn’t working properly.

Call Black Box about getting a replacement Switch.

5.2 Calling Black Box

If you determine that your Two-Port 10/100 Ethernet Switch is malfunctioning, do not attempt to alter or repair the unit. It contains no userserviceable parts. Contact Black Box at (724) 746-5500.

Before you do, make a record of the history of the problem. We will be able to provide more efficient and accurate assistance if you have a complete description, including:

• the nature and duration of the problem.

• when the problem occurs.

• the components involved in the problem.

• any particular application that, when used, appears to create the problem or make it worse.

5.3 Shipping and Packaging

If you need to transport or ship your Two-Port 10/100 Ethernet Switch:

• Package it carefully. We recommend that you use the original container.

• If you are shipping the Two-Port 10/100 Ethernet Switch for repair, make sure you include everything that came in the original package. Before you ship, contact Black Box to get a Return Materials Authorization (RMA) number.

16

NOTES

17

© Copyright 1997. Black Box Corporation. All rights reserved.

1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746

advertisement

Related manuals

Frequently Answers and Questions

What does this switch product offer?
These switches provide 10/100-Mbps and 100/100-Mbps switching.
What is the maximum distance the switches can extend a Fast Ethernet network?
Up to 100 km.
What type of ports are available on the LB9801A switch?
Two RJ-45 10/100 autosensing ports.
What are the supported standards for these switches?
They adhere to IEEE 802.3 and IEEE 802.3u (Fast Ethernet standard).
What kind of mounting options are available?
19" rack mounting for up to 2 units.
What is the operating temperature range for these switches?
32 to 104°F (0 to 40°C).
What is the power requirement for the switches?
100–240 VAC, 50–60 Hz, 1 amp maximum at 220V.

advertisement