- Computers & electronics
- Computer components
- Interface components
- Serial switch boxes
- Cross Technologies
- 2582-143
- Data Sheet
advertisement
◉
Touch to zoom
DATA SHEET CROSS TECHNOLOGIES, INC. REV_C 11/10/09 2582-143 Backup Switch, 1 for 4 The 2582-143 1 for 4 Switch provides Auto, Remote, or Manual backup protection for up to 4 block converters by using a combination of IF/L-Band relay switches and RF transfer switches for signals from a backup unit to any of the 4 online units. The 2582-143 works with standard Cross block up and downconverters by polling their monitor and control ports on a periodic basis. A defective units inputs and outputs are switched from the failed unit to the backup unit either automatically (when an alarm is detected from the failed unit), remotely or manually. Manual switching overrides Remote and Auto switching, while Remote switching overrides Auto switching. Manual selection is made by the front panel multifunction, push-button switches. Remote selection is made via a rear panel female DB9 connector. The 2582-143 is powered by redundant 100-240 ±10% VAC power supplies and is housed in a 1.75” X 19” X 16” 1RU rack mount chassis. POWER ONLINE / OFFLINE ALARMS 1 2 3 4 PROT P P P P MODE A A A A MODEL 2582 BU SWITCH MENU STATUS 1 2 1 2 3 4 BU SW 1 2 3 4 CROSS TECHNOLOGIES INC. A EXECUTE BU Front Panel EQUIPMENT SPECIFICATIONS* IF/L-Band Switch Characteristics Impedance 50 Return Loss > 12 dB Type Relay Isolation > 55 dB, DC to 1.5 GHz > 50 dB, to 2.2 GHz; Switch time 100 milliseconds Insertion Loss 1.5 dB, to 1.5 GHz; 2.0 dB, to 2.2 GHz Configuration 1 for 4, no termination RF Switch Characteristics Impedance Return Loss Type Isolation Switch time Insertion Loss Configuration Controls, Indicators Manual Selection Remote Selection Power Alarms Online/Off-line CH 1 CH 1 CH 2 CH 2 CH 3 CH 3 CH 4 CH 4 RF RF RF RF RF RF RF RF IN/ CONV IN/ CONV IN/ CONV IN/ CONV OUT OUT OUT OUT BU RF IN/OUT BU RF CONV BU IF/L-BAND IN/OUT BU IF/L-BAND CONVERTER CH 4 IF/L-BAND IN/OUT 50 > 12 dB RF Transfer > 60 dB, to 15 GHz 100 milliseconds 1.5 dB, to 8 GHz; 2.0 dB, to 15 GHz 1 for 4, no termination CH 4 IF/L-BAND CONVERTER CH 3 IF/L-BAND IN/OUT CH 3 IF/L-BAND CONVERTER CH 2 IF/L-BAND IN/OUT CH 2 IF/L-BAND CONVERTER CH 1 IF/L-BAND IN/OUT CH 1 IF/L-BAND CONVERTER CONTROL LOGIC UNIT UNIT UNIT UNIT BU SW 1 2 3 4 UNIT Push-button switches RS 232C (RS 422/485, option Q), 9600 baud Green LEDs Red LEDs Green LEDs |----- REMOTE and ALARM -----| Block Diagram Other RF Connectors L-Band Connectors Alarm/Remote Conns Size Power SMA (female) BNC (female) DB9 (female) 19 inch, 1RU standard chassis 1.75” high X 16.0” deep 100-240 ±10% VAC, 47-63 Hz, 45 watts max.; Redundant power supplies *+10˚C to +40˚C; Specifications subject to change without notice Cross Technologies, Inc. • 6170 Shiloh Road • Alpharetta, GA 30005 www.crosstechnologies.com • 770.886.8005 • FAX 770.886.7964 ALARM N/C
advertisement
Related manuals
advertisement