DATA SHEET
CROSS TECHNOLOGIES, INC.
REV_C
11/10/09
2582-143 Backup Switch, 1 for 4
The 2582-143 1 for 4 Switch provides Auto, Remote, or Manual backup protection for up to 4 block converters by using a combination
of IF/L-Band relay switches and RF transfer switches for signals from a backup unit to any of the 4 online units. The 2582-143 works
with standard Cross block up and downconverters by polling their monitor and control ports on a periodic basis. A defective units
inputs and outputs are switched from the failed unit to the backup unit either automatically (when an alarm is detected from the failed
unit), remotely or manually. Manual switching overrides Remote and Auto switching, while Remote switching overrides Auto switching.
Manual selection is made by the front panel multifunction, push-button switches. Remote selection is made via a rear panel female
DB9 connector. The 2582-143 is powered by redundant 100-240 ±10% VAC power supplies and is housed in a 1.75” X 19” X 16” 1RU
rack mount chassis.
POWER
ONLINE / OFFLINE
ALARMS
1
2
3
4
PROT
P
P
P
P
MODE
A
A
A
A
MODEL 2582
BU
SWITCH
MENU
STATUS
1
2
1
2
3
4
BU SW
1
2
3
4
CROSS TECHNOLOGIES INC.
A
EXECUTE
BU
Front Panel
EQUIPMENT SPECIFICATIONS*
IF/L-Band Switch Characteristics
Impedance
50 Return Loss
> 12 dB
Type
Relay
Isolation
> 55 dB, DC to 1.5 GHz
> 50 dB, to 2.2 GHz;
Switch time
100 milliseconds
Insertion Loss
1.5 dB, to 1.5 GHz;
2.0 dB, to 2.2 GHz
Configuration
1 for 4, no termination
RF Switch Characteristics
Impedance
Return Loss
Type
Isolation
Switch time
Insertion Loss
Configuration
Controls, Indicators
Manual Selection
Remote Selection
Power
Alarms
Online/Off-line
CH 1 CH 1 CH 2 CH 2 CH 3 CH 3 CH 4 CH 4
RF
RF
RF
RF
RF
RF
RF
RF
IN/ CONV IN/ CONV IN/ CONV IN/ CONV
OUT
OUT
OUT
OUT
BU
RF
IN/OUT
BU
RF
CONV
BU
IF/L-BAND
IN/OUT
BU
IF/L-BAND
CONVERTER
CH 4
IF/L-BAND
IN/OUT
50 > 12 dB
RF Transfer
> 60 dB, to 15 GHz
100 milliseconds
1.5 dB, to 8 GHz;
2.0 dB, to 15 GHz
1 for 4, no termination
CH 4
IF/L-BAND
CONVERTER
CH 3
IF/L-BAND
IN/OUT
CH 3
IF/L-BAND
CONVERTER
CH 2
IF/L-BAND
IN/OUT
CH 2
IF/L-BAND
CONVERTER
CH 1
IF/L-BAND
IN/OUT
CH 1
IF/L-BAND
CONVERTER
CONTROL
LOGIC
UNIT UNIT UNIT UNIT BU SW
1
2
3
4
UNIT
Push-button switches
RS 232C (RS 422/485, option Q), 9600 baud
Green LEDs
Red LEDs
Green LEDs
|----- REMOTE and ALARM -----|
Block Diagram
Other
RF Connectors
L-Band Connectors
Alarm/Remote Conns
Size
Power
SMA (female)
BNC (female)
DB9 (female)
19 inch, 1RU standard chassis 1.75” high X 16.0” deep
100-240 ±10% VAC, 47-63 Hz, 45 watts max.; Redundant power supplies
*+10˚C to +40˚C; Specifications subject to change without notice
Cross Technologies, Inc.
•
6170 Shiloh Road • Alpharetta, GA 30005
www.crosstechnologies.com
• 770.886.8005 • FAX 770.886.7964
ALARM