BEA LO21 User guide
Annonce
Annonce
PRODUCT
DESCRIPTION
USERS GUIDE
LO-21K
LOCKOUT RELAY
The LO-21K (PN: 10LO21K) is a micro-processed lock out module designed to operate with the Keane Monroe
3100 Swing Door System ONLY! The LO-21K is used with BEA’s Bodyguard or DK-12 overhead presence sensor. The LO-21K interprets door open or door closed position based upon motor voltage input. The motor voltage information is sent from the LO-21K to the Bodyguard or DK-12 via data lines. The LO-21K provides optional safety beam input to override the inhibit signal during closing. For example, when the safety beam path is blocked or interrupted during closing, the inhibit data will be cancelled, thus initiating a safety signal to the door control safety input.
ANSI / BHMA 156.10-2005 requires the use of a sensor or photobeam on the swing side of the door when using a header mounted safety sensor, such as the Bodyguard or DK12. For more information reference the ANSI 156.10 standard.
The LO-21K module is designed specifically for the KM3100 K-Control only, and must not be used on other brands/models of operators! Damage to module may result if this occurs.
TECHNICAL
SPECIFICATIONS
DESCRIPTION
Power Supply
Operating Frequency
Power Consumption
Output
Max. Voltage - Relay Contact
Max. Current - Relay Contacts (both)
SPECIFICATION
12-24 Volts AC / 15-24 Volts DC
4 MHz (Microprocessor)
10 mA at rest, 50 mA Max.
2 x SPST Relays
60V DC, 120V AC
2A DC, 0.5A AC
COMPONENT ID
Dipswitches
Green LED – Safety
Red LED – Lock out time
SAFETY
PRECAUTIONS
!
CAUTION
•
Shut off all power going to the header before attempting any wiring procedures.
•
Maintain a clean & safe environment when working in public areas.
•
Constantly be aware of pedestrian traffic around the door area.
•
Always stop pedestrian traffic through the doorway when performing tests that may result in unexpected reactions by the door.
•
Always check placement of all wiring before powering up to insure that moving door parts will not catch any wires and cause damage to equipment.
•
Ensure compliance with all applicable safety standards (i.e. ANSI A156.10) upon completion of installation.
75.5049.02 20060605 Page 1 of 4
ELECTRICAL
INSTALLATION
OPERATION
The LO-21K can be used with the BEA SBK-111 safety beams, in addition to dry contact safety beams, for retrofit purposes. Since the SBK-111's are wet output and all other safety beams have a dry output, there are some wiring differences between the two. The SBK-111 is wired as shown in the wiring diagram.
If using dry contact safety beams, such as BEA’s Microcell, remember these changes:
1. Power the safety beams with the same transformer that is used for the LO-21K.
2. The black/ white striped wire is not used and should be taped off.
3. The gray and purple wires of the LO-21K go to the NO and COM dry contacts of the safety beams.
All LO-21K wiring must be accomplished with the module unplugged. If the red / white striped and white wires (data wires) touch each other when power is applied, damage to the unit will result. white green brown brown white
+ +
SBK-111/SW
BODYGUARD
DK12
DATA+
DATA-
NO
COM
PWR
PWR
7
6
NC 5
4
3
2
1 red/white white green* blue* brown orange
LO-21K
LOCKOUT
RELAY
115 VAC
24 V
TRANSFORMER
3100
DOOR
CONTROL
MOTOR
VOLTAGE
RED
WHITE
NOT
USED
*Please note: Connect the dashed lines
(green, blue, black/ white, purple & gray)
ONLY if safety beams are used.
MOTOR
The function of the LO-21K with the BODYGUARD / DK-12 is as follows. The LO-21K provides the BODYGUARD /
DK-12 with information on the position of the door by data lines. These data lines (RED/WHITE & WHITE) enable the BODYGUARD / DK-12 to be inhibited during the closing cycle of the door and to switch its pattern settings according to the position of the door. For example, when the door is in its fully open position, a signal will be sent through the RED/WHITE and WHITE to the BODYGUARD / DK-12 to indicate that the door is in this position, and the BODYGUARD / DK-12 will switch to a “door open” pattern. Once the door starts to close, the LO-21K will sense the reversing (change of polarity) of the motor and will inhibit the BODYGUARD / DK-12 for the preset lock out time delay. During this time, the red LED at the sensor will be off.
In addition to providing communication to the BODYGUARD / DK-12, the LO-21K provides a safety connection between the safety beams and the door control. The BLACK/WHITE & RED/WHITE wires provide the SBK-111 safety beams with the necessary voltage to operate. If the safety beams are blocked, the GRAY & PURPLE wires will receive a signal for the LO-21K to trigger the safety of the door control via the BLUE & GREEN wires of the LO-
21K. The safety signal received by the door control will hold the door in its position. If the safety beams are broken during the closing cycle, the BODYGUARD / DK-12’s pattern will be adjusted to its “door closed” pattern and the safety of the door will be triggered. When the safety beam path is reestablished, the door will continue to close in safety swing until the door reaches the fully closed position, at which time activation will be possible only if there is no detection at the Bodyguard.
75.5049.02 20060605 Page 2 of 4
OPERATION
CONT.
SET-UP
INSTRUCTIONS
DIPSWITCH
SETTINGS
6
7
8
9
10
11
12
13
14
15
16
Time
Delay
(sec)
1
2
3
4
5
WITHOUT SAFETY BEAMS:
The new LO-21K provides communication through data lines to the BODYGUARD / DK-12 to inhibit the
BODYGUARD / DK-12 in the closing cycle of the door, therefore the GREEN & BLUE wires of the LO-21K no longer have to be connected to the BODYGUARD / DK-12. If the GREEN & BLUE wires are connected, no damage to the unit will result.
WITH SAFETY BEAMS:
When safety beams are installed, the LO-21K provides the safety signal to the door control when the beams have been blocked. Therefore, the GREEN & BLUE wires of the LO-21K must be wired in parallel with the BODYGUARD
/ DK-12 connection to the safety and common of the door control.
Upon powering the LO-21K , make sure that the red light on the front of the LO-21K comes on when the door is in its closing cycle. If it does not come on, reverse the black and red wires from the LO-21K to the motor input for DC units. If the unit is AC, ensure that the AC power is being switched on and off at the point of connection for the red and black wires. Also, if using safety beams, ensure that the green light comes on and goes out when the beams are blocked and unblocked respectively. Correct any faults before proceeding.
STOP
If the Bodyguard learns a “door closed” position, but does not execute a learn for the
“open door position”, place the door to a hold open position. With a BEA remote control, unlock the Bodyguard, and with the door in the open position, press the Magic Wand key and then the number 2 – the Bodyguard should begin flashing green to signify a set-up.
If it does not, this will be a quick indication that the improper data is being sent for the
“open door” position. Check to insure that data exists on the data lines leading into the
Bodyguard. In the full open position, voltage should be approximately 12 volts DC.
Voltage should be approximately 7.8 volts DC while the door is closing, and 0 volts DC once closed. If it is not, check the data lines, as well as the LO-21K to Motor wires (red & black). Refer to the Bodyguard User’s Guide for further information if necessary.
Time delay is the only adjustment on the LO-21K. It is changed by dipswitches 1 through 5, located on the front of the unit and can be set to achieve a 0 to 31 second delay. The time delay must be set so that the red light on the
LO-21K remains on for the entire closing cycle. As soon as the door reaches the jamb, the red light should go out.
The time delay will not begin until the motor begins rotating in a direction that allows door to close. If motor rotation stops, the time delay will not stop counting down. Interruption of the time delay will only result if re-activation of the door is recognized or the SBK-111 safety beams were broken. Therefore, if the closing speed of the door is changed, the time delay on the LO-21K must also be adjusted to accommodate the time difference for the duration of the closing cycle.
Red LED corresponds with lockout time, and will illuminate when the door is in a closing cycle.
Green LED illuminates upon detection signal from the lockout safety beams.
Set the dipswitches according to the chart below to achieve the desired lockout time
(7 Second Default) dip 1
1 sec
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF dip 2
2 sec
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF dip 3
4 sec
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON
OFF dip 4
8 sec
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON dip 5
16
sec
OFF
OFF
OFF
OFF
OFF
Time
Delay
(sec)
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31 dip 1
1 sec
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON dip 2
2 sec
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON dip 3
4 sec
OFF
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
ON
ON
ON
ON dip 4
8 sec
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON dip 5
16 sec
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
75.5049.02 20060605 Page 3 of 4
TROUBLE-
SHOOTING
COMPANY
CONTACT
SYMPTOM PROBABLE CAUSE CORRECTIVE ACTION
Red LED does not come on during the
1. Red and black wires are reversed
(polarity sensitive)
1. Reverse the polarity of the motor wires
2. Check voltage supply to LO-21K: 12-24 closing cycle resistor not installed
3. Faulty input power or data
Volts AC / 15-24 Volts DC
3. Check continuity on orange, brown, red and black wires
Door will not open or close (green LED is on) blocked
2. Faulty safety beam receiver or transmitter beam path
2. Check all safety beam related wiring operation beam
4. Faulty safety beam wiring
Door will not recycle open when activated during the closing cycle
1. Lockout time is not long enough.
Red LED goes out before door gets fully closed.
2. Data wires are reversed at the
Bodyguard / DK-12
1. Increase the lockout time. Refer to
Dipswitch chart on Page 4.
2. Reverse the data wires at the Bodyguard
/ DK-12
3. Check continuity on the data wires (red wire and red/white striped wire)
Green LED does not come on when safety beams are blocked
1. Faulty safety beam receiver
2. Faulty connection on purple and gray wire from LO-21K
1. Test beams and LO-21K with multi-meter
2. Perform continuity test on purple and gray wires
Improper voltage reading on data lines at
LO-21K
1. Incorrect wiring at LO-21K
2. Faulty LO-21K
1. Check to ensure that the polarity is correct at terminals 6 & 7 on the Bodyguard.
2. If data line voltage remains constant at the
LO-21K for the open and closed positions, and all wiring is Ok, replace faulty LO-21K
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call B.E.A.,
Inc. If you must wait for the following workday to call B.E.A., leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.
The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beainc.com
.
West: 1-888-419-2564
South-East: 1-800-407-4545
US and Canada: 1-866-249-7937
Mid-West: 1-888-308-8843
North-East: 1-866-836-1863
Canada: 1-866-836-1863
75.5049.02 20060605 Page 4 of 4