Chenbro RM312 User guide


Add to my manuals
29 Pages

advertisement

Chenbro RM312 User guide | Manualzz

RM312 Rackmount Chassis

User Guide

Rev. 01

Contents

YOUR RACKMOUNT CHASSIS........................................................................1

F EATURES .......................................................................................................1

S PECIFICATIONS ...............................................................................................2

L AYOUT ..........................................................................................................3

INSTALLATION ..............................................................................................5

F OR YOUR SAFETY .............................................................................................5

P ARTS L IST .....................................................................................................6

I NSTALLING H ARD D ISK D RIVES (HDD).............................................................8

I NSTALLING AN I NTERNAL HDD .......................................................................8

I NSTALLING A FDD ......................................................................................9

I NSTALLING A S LIM CD/DVD-ROM..................................................................9

C HANGING THE 80 MM S YSTEM F ANS ............................................................... 10

I NSTALLING THE B ACKPLANE ( OPTIONAL ITEM ) ................................................... 11

I NSTALLING A M OTHERBOARD ( OPTIO NAL PART ).................................................. 13

I NSTALLING THE P OWER S UPPLY U NIT ( OPTIONAL DEVICE )..................................... 13

I NSTALLING THE G ENERAL R ACK R AIL K IT ( OPTIONAL PART )................................... 14

I NSTALLING THE B EZEL ............................................................................... 15

BACKPLANE BOARD.....................................................................................16

R AID B ACKPLANE S UPPORTS : .............................................................................. 16

B ACKPLANE L AYOUT ......................................................................................... 17

P IN A SSIGNMENTS ........................................................................................... 18

LED BOARD..................................................................................................20

F EATURES ..................................................................................................... 20

LED B OARD L AYOUT ........................................................................................ 21

P IN A SSIGNMENTS ........................................................................................... 22

APPENDIX A ................................................................................................24

O PTIONAL C ABLES ........................................................................................... 24

APPENDIX B ................................................................................................25

P OWER C ORD P LUG O PTIONS .............................................................................. 25

NOTICES......................................................................................................26

CONTACT INFORMATION ............................................................................27

H EADQUARTERS .............................................................................................. 27

RM312 User Guide ii 19" Rackmount Chassis

Y

OUR

R

ACKMOUNT

C

HASSIS

The RM312 19" rackmount chassis supports a variety of high-density system configurations and features the latest in server-chassis technology.

Features

Top Cover

Ø Screw-less design for easy installation and maintenance

Ø Quick reference guide affixed to the inside

Front Panel Controls and Indicators

Ø Front access USB2.0 ports offer flexibility

Ø Alarm mute button to disable audible warnings

Ø System reset button

Ø LEDs for system signals (power, HDD access, LAN1, LAN2, and failure event)

Hard Drive Trays

Ø 12 hard drive trays (may serve NAS, RAID, or media streaming applications)

Ø Hot-swappable for ease of use

Drive Bays

Ø Two external bays (one slim CD/DVD-ROM and one standard FDD)

Ø Internal HDD bay for operating system

Backplanes

Ø Supports 3pcs of 4-in-1 IDE ATA133/Ultra320 SCSI/SATA backplanes

Motherboard

Ø Extended ATX form factor up to 12”×13”

Ø Supports numerous brands (i.e. Intel

® , Supermicro ® , Tyan, Gigabyte ™ , Asus ® etc.)

CPU

Ø Supports Intel

® P4, Intel ® DP Xeon ™ , AMD Athlon ™

Ø Excellent thermal solution for DP Xeon up to 3.06+GHz

PSU

Ø Supports single or redundant 3U power supply

MP, or AMD Opteron ™

Ø Power output up to 800W (depends on power supply)

Cooling Fans

Ø Four 80mm ball-bearing fans (two 60mm rear fans optional)

Slot Openings

Ø 7 PCI expansion slots at the rear

,

RM312 User Guide 1 19" Rackmount Chassis

Specifications

Model Name RM312

Standard

M/B Form Factor

EIA-RS310D

Extended ATX (12"x13")

CPU Type Supported

Dimension (D*W*H)

Drive

Bays

PSU

External

Internal

HDD Trays

Form Factor

Watts

Indicators

Front Controls

System Security

5.25”

3.5”

3.5”

P4/DP Xeon/Athlon MP/Opteron

660*430*176mm

26*16.9*5.2"

1 x slim CD/DVD-ROM

1 x FDD

1

12

Single or Redundant

350W ~ 800W

Power On/Off, HDD/LAN activity, fan failure, and overheat warning

Power On/Off, System Reset, Alarm Reset, and USB2.0 port x 2

N/A

Cooling Fan

Slot Opening

Material

Sheet Metal Thickness

Net Weight (chassis only)

Cubic Feet

Reference Container Load

(single packing)

Standard 4 × 80mm middle fans

Optional 2 × 60mm rear fans

7

SGCC

1.2mm

20’

40’

15.1kg

5.27

176 units

368 units

Backplane IDE/SCSI/SATA

RM312 User Guide 2 19" Rackmount Chassis

Layout

Chassis

Two 60mm Exhaust Fans (optional)

Standard ATX/

Extended ATX M/B

4x 80mm Easy Swap

Fan Modules

Slim CD-ROM

12x Hard Drive

Trays

Front Panel Inset

Front Access Panel

Single or n+1 Redundant

Power Supply (optional)

Internal 3.5" Hard Drive

Standard FDD or Internal HDD

See Front Panel Inset for details

A

A. HDD Tray Activity LEDs (1-12)

B. USB2.0 Port x2

C. LAN1 and LAN2 LEDs

D. Alarm Mute Button

E. System Reset Button

B C D E F G H I

F. Failure LED

G. System HDD Activity LED

H. Power LED

I. Power Switch

RM312 User Guide 3 19" Rackmount Chassis

Back Panel

Two 60mm Exhaust Fans (optional)

Single or n+1

Redundant

Power Supply

(optional)

System I/O Ports

(M/B dependent)

Seven PCI Slots

RM312 User Guide 4 19" Rackmount Chassis

I

NSTALLATION

For your safety

When deciding on a location for your RM312 rackmount chassis, please take the following into consideration:

Electric Power: The power cord is what powers on/off your chassis, so try to place the chassis near a power outlet for convenience. Next, be aware of RM312's power rating to avoid overloading its circuits. Then make sure the connections are grounded properly.

Temperature: Whenever dealing with an enclosed environment, temperature must be a consideration. Inside the chassis, the temperature will most likely be higher than that of the room it is located in. To make certain that RM312 operates effectively and to prevent possible heat-related problems, be sure to have plenty of ventilation (i.e. additional cooling fans and extra space between devices).

RM312 User Guide 5 19" Rackmount Chassis

Parts List

• RM312 Rackmount Chassis (P/N: 90-331200-001)

• Accessory Box (P/N: 84-331210-001)

- CD-ROM Adapter (P/N: 80-091801-011)

- Screws and Spacers:

D EVICE

P ACKET P ART

N O .

S CREW

I MAGE ( S )

HDD Tray 70-000000-149

Internal HDD 70-000000-149

FDD 70-331900-101

Slim CD/DVD-ROM 70-331900-101

Backplane 70-331900-102

Motherboard 70-331100-101

I NSTALLATION T OOL ( S )

R EQUIRED

Phillips Screwdriver

Phillips Screwdriver

Phillips Screwdriver

Phillips Screwdriver

Phillips Screwdriver

Nut Driver

Phillips Screwdriver

Nut Driver

RM312 User Guide 6 19" Rackmount Chassis

- Cables: (refer to Appendix A for further cable options)

C ABLE P ART N O . C ABLE A PPEARANCE

FDD 26-073123-001

CD/DVD-ROM 26-073123-004

HDD 1-to-2 26-073118-007

Big 4P to big

4P/small 4P

26-113215-001

Big 4P to big

4P+250mm big 4P

26-113215-003

• Optional Items:

- 26” General Device Rack Rail Kit

- 60mm Rear Exhaust Fans x 2

- Power Cord (refer to Appendix B for plug options)

RM312 User Guide 7 19" Rackmount Chassis

Installing Hard Disk Drives (HDD)

?

?

?

1. Press latch towards the right to open the lever release and slide the HDD tray out of the chassis.

2. Mount the hard drive onto the tray with four screws from the HDD screw packet

(P/N: 70-000000-149).

3. Slide the HDD tray back into the case and press the lever back in to secure it.

4. Repeat the procedure for the remaining hard drives.

Installing an Internal HDD

( STANDARD ) ( OPTION )

?

?

?

?

1. Remove the securing screw to slide back and take out the bracket.

2. Attach the HDD to the bracket with four additional screws from the included HDD screw packet (P/N: 70-000000-149).

3. Slide the bracket forward, following the three guide pins, until it fits into place.

4. Reattach the original screw.

RM312 User Guide 8 19" Rackmount Chassis

Installing a FDD

?

?

?

1. Remove the securing screw to move back and take out the bracket.

2. Remove the bracket's FDD cover screws.

3. Attach the FDD onto the bracket with four additional screws from the included

FDD screw packet (P/N: 70-331900-101).

4. Slide the bracket forward, following the three guide pins, until it fits into place.

5. Reattach the original securing screw.

Installing a Slim CD/DVD-ROM

?

?

?

1. Release the securing screw to slide back and take out the bracket.

2. Release the CD-ROM's cover screws.

3. Attach the slim CD/DVD-ROM onto the bracket with four additional screws from the included CD-ROM screw packet (P/N:70-331900-101).

4. Slide the bracket forward, following the two guide pins, until it fits into place

5. Reattach the securing screw.

RM312 User Guide 9 19" Rackmount Chassis

Changing the 80mm System Fans

• Ž

1. Disconnect the fan connector from the backplane.

2. Push the press tab down, then ease the fan and its frame out of the fan bracket.

3. Pull the press tab up to release the fan from the frame.

4. Remove the four screws to take out the finger guard.

5. Replace the faulty fan with a new one.

6. Reassemble, then place back into the fan bracket and reconnect to the backplane.

RM312 User Guide 10 19" Rackmount Chassis

Installing the Backplane (optional item)

RM312 supports the following three different backplanes: SCSI, IDE, and SATA.

SCSI Backplane Assembly

IDE Backplane Assembly SATA Backplane Assembly

RM312 User Guide 11 19" Rackmount Chassis

?

?

?

?

1. With ten screws from the backplane screw packet (P/N: 70-331900-102), attach the backplane to the bracket in the chassis as shown in the diagram.

2. To support a second backplane, affix three hex copper spacer pins.

3. Next secure both ends of the backplane with two screws on both sides of the outer chassis.

4. Repeat steps 1-3 for remaining backplane assemblies.

5. For the topmost assembly, use the three hex copper spacers without the pins to cap it off.

6. Connect the LED cable from backplane (JP1) to LED board. The lower one connects to the 1U LED connector (J1) on the LED board; the middle one to the

2U connector (J2); and the upper one to the 3U connector (J3).

7. Now connect the Big 4p power cable from the PSU to the power connectors (J7 and J8) on the SCSI backplane.

8. Connect the fan connector to the fan pin header of the upper backplane to finish the installation, and check to see the fan sensor is enabled.

RM312 User Guide 12 19" Rackmount Chassis

Installing a Motherboard (optional part)

?

?

?

?

?

1. Use the included spacers for support from the motherboard screw packet (P/N:

70-331100-101).

2. Install the I/O gasket that came with your motherboard (M/B).

3. Next align the M/B with the chassis and I/O gasket.

4. The edge with the I/O ports should be placed at the back part of the chassis.

5. Secure M/B to the chassis with a screw.

Installing the Power Supply Unit (optional device)

?

?

1. Place the power supply unit (PSU) into in the area shown and secure it with four screws.

2. With another two screws, secure it to the other side of the chassis.

RM312 User Guide 13 19" Rackmount Chassis

Installing the General Rack Rail Kit (optional part)

Sliding Rail Guide

(inside facing chassis)

Outer Fixed Rack Rail

Screws

Inner Fixed Chassis Rail

The optional rack rail kit consists of three main parts: a pair of inner fixed chassis rails, a pair of outer fixed rack rails, and a pair of sliding rail guides. Each pair is identical, so no special attention is necessary to make the parts match either the left or the right side. No parts must be removed from the chassis in order to install the rack rail kit.

1. As they are partially assembled when packaged, you must first disassemble the rails before installing them.

Remove the inner fixed chassis rail: Pull out until a "click" is heard, then depress the locking tab and pull the inner rail completely out. Do this for both the left and right side rail assemblies.

2. Now position the same inner fixed chassis rail along the side of the RM312 chassis. Making sure the holes line up, screw the rail securely to the side of the chassis. Repeat this procedure for the other rail on the other side.

3. Next position the outer fixed rack rail/sliding rail guide assembly at the desired location in the cabinet rack, making sure to keep the sliding rail guide facing the interior of the rack. Screw the assembly securely to the rack using the included brackets. Repeat the procedure for the other side's assembly, making sure to match the exact same height and position of the rail guides facing inward.

4. Line up the rear of the inner fixed chassis rails with the front of the outer fixed rack rails, and slide the chassis towards the rear, keeping even pressure on both sides.

5. When the RM312 has been eased completely into the rack, you should hear the locking tabs "click" to finish the installation.

RM312 User Guide 14 19" Rackmount Chassis

Installing the Bezel

?

?

?

1. First detach the handles by removing the two screws from each one. Keep handles in the event you may need them again in the future.

2. Next, install the bezel supports and tighten screws securely.

3. Then fit the right side of bezel to its corresponding support and snap into place.

RM312 User Guide 15 19" Rackmount Chassis

B

ACKPLANE

B

OARD

Raid Backplane Supports:

Ø SCSI interface: Ultra 320/160 backward compatibility

Ø Hard disk drive 80pin SCA2 Ultra 320/160 backward compatibility

Ø 4-bay hard disk drive inrush current control for hot-swapping

Ø SCSI-IN and SCSI-OUT connector (right angle, 68-pin female)

Ø SCSI on board terminator On/Off function and On/Off LED

Ø Hard disk drive Delay_Start or Remote_Start mode function

Ø SCA2 ID setting function default is ID0, ID1, ID2, ID3

Ø 5pcs external fan speed monitoring, fan failure buzzer alarm, and red LED active function

Ø Fan disable function

Ø One on-board temperature sensor with adjustable alarm level (50 C or 60 C); buzzer sounds when temperature rises above alarm level

Ø 2pcs power connectors in big 4-pin, right angle, D-type

Ø Power On LED

Ø 4 external LEDs monitoring for HDD installation, HDD access, and fan overheating fail and buzzer mute connector pin

RM312 User Guide 16 19" Rackmount Chassis

Backplane Layout

Dimensions: 411.60*51.44*2.4mm

S2

J1

S3

J2

RM312 User Guide

S4

J3

S5

J4

17

J6

J8

J7

S6

FAN4

FAN5

JP1

S1

J5

BZ1

FAN1

FAN2

FAN3

19" Rackmount Chassis

Connectors and Switches

No.

J1

J2

J3

J4

J5

J6

J7

J8

JP1

S1

S2

Description

HDD1 SCA2 Connector

HDD2 SCA2 Connector

HDD3 SCA2 Connector

HDD4 SCA2 Connector

SCSI in 68pin Connector

SCSI in 68pin Connector

DC Power Input for Big 4P

DC Power Input for Big 4P

For LED Output Header

Function Set Switch

HDD1 ID-Set Switch

Pin Assignments

No.

S3

S4

S5

S6

FAN1

FAN2

FAN3

FAN4

FAN5

BZ1

Description

HDD2 ID-Set Switch

HDD3 ID-Set Switch

HDD4 ID-Set Switch

Function Set Switch

Fan Connector

Fan Connector

Fan Connector

Fan Connector

Fan Connector

Buzzer

S2, S3, S4, S5: SCSI ID Settings

SCSI ID

12

13

14

15

8

9

10

11

4

5

6

7

0

1

2

3

Position1

Off

On

Off

On

Off

On

Off

On

Off

On

Off

On

Off

On

Off

On

Position2

Off

Off

On

On

Off

Off

On

On

Off

Off

On

On

Off

Off

On

On

Ø Avoid setting SCSI ID 7 for SCSI drive. It normally hosts the SCSI host adapter.

Ø The default setting for SCSI drives are from ID0, ID1, ID2, and ID3.

Position3

Off

Off

Off

Off

On

On

On

On

Off

Off

Off

Off

On

On

On

On

Position4

On

On

On

On

On

On

On

On

Off

Off

Off

Off

Off

Off

Off

Off

RM312 User Guide 18 19" Rackmount Chassis

S1: Function Settings*

Switch Switch On Switch Off

Switch 1 HDD motor spin up delay mode Normal

Switch 2

Switch 3 randomly.

HDD motor spin up remote mode Normal

Terminator On Terminator Off

* With this jumper, the user can set the SCSI HDD motor to start in sequence or

S6: Fan and Temperature Settings

Switch

Switch 1

Switch 2

Switch 3

Switch 4

Switch 5

Switch 6

Switch On

FAN 1 sensor disabled

FAN 2 sensor disabled

FAN 3 sensor disabled

FAN 4 sensor disabled

FAN 5 sensor disabled

Temperature Set 50°C

Switch Off

FAN 1 sensor enabled

FAN 2 sensor enabled

FAN 3 sensor enabled

FAN 4 sensor enabled

FAN 5 sensor enabled

Temperature Set 60°C

JP1: Display Board Signals Output

Pin 1

Pin 3

Pin 5

Pin 7

Pin

Pin 9

Pin 11

Output Pin

HDD1 LED +

HDD2 LED +

HDD3 LED +

HDD4 LED +

Pin 2

Pin 4

Pin 6

Pin 8

Fail LED + Pin 10

Buzzer Mute Switch + Pin 12

Output

HDD1 LED -

HDD2 LED -

HDD3 LED -

HDD4 LED -

Fail LED -

Buzzer Mute Switch -

Fan 1, Fan 2, Fan 3, Fan 4, Fan 5: Connector Pin Assignments

Pin

1

2

3

Description

GND

VDD

SENSOR

J7 and J8: Big 4P Pin Assignments

Pin

1

2

3

4

Description

VDD

GND

GND

VCC

RM312 User Guide 19 19" Rackmount Chassis

LED B

OARD

Features

Ø PCB Layers: 2

Ø 1 HDD power and access LED monitor

Ø 1 buzzer alarm mute switch

Ø 1 system reset switch

Ø 1 system power switch

Ø 1 power green LED indicator

Ø 1 local HDD yellow LED indicator

Ø 1 fails red LED indicator

Ø 2 USB port

Ø 2 LAN LED indicator

Ø 4 connectors for 1U, 2U, 3U, 4U LED boards

Ø 2 x 10 pin connectors for USB port

Ø 1 system connector

RM312 User Guide 20 19" Rackmount Chassis

LED Board Layout

Dimensions: 130.0*45.0*1.6mm

Connectors and Switches

NO.

J1

J2

J3

J4

J5

SW1

SW2

SW3

Description

1U LED

2U LED

3U LED

4U LED

System

Alarm Mute SW

System Reset SW

Power SW

NO.

LED1

LED2

LED3

LED4

LED5

LED6-1

LED6-2

LED6-3

Description

HDD1

HDD2

HDD3

HDD4

LAN Activity

Fail

HDD

Power

RM312 User Guide 21 19" Rackmount Chassis

Pin Assignments

USB Pin Outs

1

3

5

7

9

Pin # Description

USB1 Power

USB1 Data -

USB1 Data +

USB1 GND

Key

Pin #

9

11

13

1

3

5

7

J1: 1U LED Board Pin Outs

Description

LED11 +

LED12 +

LED13 +

LED14 +

+5V VCC

Mute

None

J2: 2U LED Board Pin Outs

Pin #

1

3

5

7

9

11

13

Description

LED21 +

LED22 +

LED23 +

LED24 +

+5V VCC

Mute

None

Pin #

9

11

13

1

3

5

7

J3: 3U LED Board Pin Outs

Description

LED31 +

LED32 +

LED33 +

LED34 +

+5V VCC

Mute

None

2

4

6

8

10

Pin # Description

USB2 Power

USB Data -

USB2 Data +

USB2 GND

None

2

4

6

8

10

12

14

Pin #

GND

GND

GND

GND

Fail

GND

Key

Description

2

4

6

8

10

12

14

Pin #

GND

GND

GND

GND

Fail

GND

Key

Description

2

4

6

8

10

12

14

Pin #

GND

GND

GND

GND

Fail

GND

Key

Description

RM312 User Guide 22 19" Rackmount Chassis

Pin #

1

3

5

7

9

11

13

J4: 4U LED Board Pin Outs

Description

LED41 +

LED42 +

LED43 +

LED44 +

+5V VCC

Mute

None

Pin #

1

3

5

7

9

11

J5: System Pin Outs

Description

Reset

Power Switch

Power LED +

HDD LED +

LAN1 LED +

LAN2 LED +

2

4

6

8

10

12

14

Pin #

GND

GND

GND

GND

Fail

GND

Key

Description

2

4

6

8

10

12

Pin # Description

Reset GND

Power Switch GND

Power LED -

HDD LED -

LAN2 LED -

LAN2 LED -

RM312 User Guide 23 19" Rackmount Chassis

A

PPENDIX

A

Optional Cables

USB:

T YPE L ENGTH

Intel Spec 750mm

P ART N O .

26-033219-001

C ABLE A PPEARANCE

Universal Spec 750mm

IDE:

T YPE

ATA-133 IDE

L ENGTH

700mm

26-033219-002

P ART N O .

26-073215-001

C ABLE A PPEARANCE

ATA-133 IDE

SATA:

T YPE

560mm

L ENGTH

26-073118-006

P ART N O .

Serial ATA 700mm 26-123215-001

C ABLE A PPEARANCE

Serial ATA

RM312 User Guide

560mm

24

26-123215-002

19" Rackmount Chassis

South Africa

Taiwan

USA

UK

RM312 User Guide

Greece

Italy

Japan

A

PPENDIX

B

Power Cord Plug Options

C OUNTRY /R EGION P ART N O .

Europe 34-032100-001

34-073100-002

34-023100-001

34-013100-002

34-083100-001

34-013100-001

34-043100-002

25

C ONNECTOR

19" Rackmount Chassis

N

OTICES

© 2003 Chenbro Micom Co., Ltd.

All rights reserved

Chenbro Micom Co., Ltd. reserves the right to make improvements to the products described in this manual at any time. Specifications and features are subject to change without prior notice.

No part of this manual may be reproduced, copied, translated, or transmitted in any form or by any means without the prior written permission of Chenbro Micom Co., Ltd. Information provided in this manual is intended to be accurate and reliable. However, Chenbro Micom Co., Ltd., assumes no responsibility for its use, nor for any infringements upon the rights of third parties, which may result from its use.

Acknowledgements

Intel ® Pentium

Athlon TM

® 4, Intel ® Xeon TM

MP and AMD Opteron TM trademark of 3ware Inc. Promise ®

, Intel ® SE7500WV2 are trademarks of Intel Corporation. AMD

are trademarks of Advanced Micro Devices, Inc. 3ware ® is a

is a trademark of Promise Technology, Inc. Serverworks™ is a trademark of Serverworks Corporation.

All other product names or trademarks mentioned herein are the properties of their respective owners.

P/N:

Version 1.0

RM312 User Guide 26 19" Rackmount Chassis

C

ONTACT

I

NFORMATION

Headquarters

CHENBRO MICOM CO., LTD.

150 Jian Yi Road, 15F

Chung Ho City 235, Taipei County

Taiwan

Tel: +886 (2) 8226-5500

Fax: +886 (2) 8226-5423

E-mail: [email protected]

Website: www.chenbro.com.tw

CHENBRO MICOM (USA) INC.

2260 S. Haven Ave., Unit E

Ontario, CA 91761

USA

Tel: 1-909-947-3200

Fax:1-909-947-4300

E-mail: [email protected]

CHENBRO EUROPE B.V.

De Pinckart 54, 5674 CC Nuenen

The Netherlands

Tel: +31 (40) 295-2045

Fax: +31 (40) 295-2044

E-mail: [email protected]

RM312 User Guide 27

CHENBRO UK

8 Ledbury Avenue, Davyhulme

Manchester, M41 7AL

UK

Tel: +44 (161) 749-9015

Fax: +44 (161) 749-9219

E-mail: [email protected]

CHENBRO CHINA BEIJING

Room 1502-1503 FUDI TOWER

No.29, Yard #9, AnNingZhuang West Road

Haidian District, Beijing 100085

China

Tel: +86 (10) 8274-3036/37/38/39

Fax: +86 (10) 8274-3035

E-mail: [email protected]

19" Rackmount Chassis

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement