Essentia (NV-E6GM).
Zones 1-6 Power Amplifier Outputs
Continuous Average Output Power
Two channels driven 30-20kHz @ 1% THD
Rated Distortion (1/2 power)
Rated Impedance
Damping Factor
Frequency Response (20-20kHz)
40W (20W x 2)
0.40%
6 ohm
50+
± 2dB
Zones 1,2 Preamplifier Outputs
Variable Output
Fixed Output
Impedance
0-2.4V RMS
2.4V RMS
1k ohm
Source Inputs 1-6
Input Impedance
Input Sensitivity for Rated Power
Input Overload
20K
300mV RMS
2.4V RMS
Emitter Outputs
Source Outputs
Sum Outputs
Output Drive
Output Drive Voltage
Compatible with single and dual emitters
System
System On Output
External Mute Input
6
1
Current 20mA
5VDC
5VDC @ 20mA
3.3-10VDC
Specifications
Zone Trigger Outputs
Output Power
Outputs
Power Requirements
Power Supply
Power Consumption all channels at
maximum available output
Power Consumption at average
operating conditions
Power Consumption no signal
Standby Power
5VDC @ 20mA
2 (zones 1, 2)
85-265VAC 50/60Hz
150VA (150W)
70VA (70W)
18VA (12W)
0.8W
Regulatory Approvals
USA Safety Listing (UL 6500)
Canada Safety Listing (CAN/CSA E60065.00)
CE Listing/SEMKO (EN60065, EN55013, EN55020,
EN6100-3-2, EN6100-3-3/A1)
Physical Specifications
Unit Size (mm)
Unit Size (inch)
Unit Weight (kg)
Unit Weight (lbs)
44 H x 430 W x 250 D
1 3/4 H x 17 W x 9 7/8 D
3.0
6.65
Shipping Specifications
Shipping Size (mm)
Shipping Size (inch)
Shipping Weight (kg)
Shipping Weight (lbs)
265 H x 558 W x 375 D
10 1/2 H x 22 W x 14 3/4 D
7.5
16.5
NuVo reserves the right to change specifications without
notice.
Office Toll Free: 866.796.4904
Office Direct: 859.817.7200
Email: [email protected]