광고
광고
Telemecanique Sensors
The essential guide of Detection
Simply easy!
™
Telemecanique Sensors
Simply easy!™
Telemecanique
brand has a 9 decades history manufacturing factory automation and safety sensors. Telemecanique wide ranges are most reliable and robust hence second to none on the market.
Our aim is to
simplify the life of our customers
, allowing them to concentrate on their core added value and machine performance.
This is why Telemecanique Sensors design and manufacture their products based on the following values:
•
Simplicity and modularity
•
Easy to choose and select
•
Easy to install and maintain
•
Expert services to share our know-how
Connect with the experts
● A dedicated Sales team: trained and experienced sales professionals are available to help you with any sensing application.
● Telemecanique Sensors team: are available for pre and post sales support. We become an extension of your team and we share our expertise with you.
www.tesensors.com
Detection
Limit switches, OsiSense XC ................................................................................................................. 4 to 13
Detection by contact of rigid objects
Sensors for pressure control, OsiSense XM, ZM ................................................................... 14 to 19
Detection by contact with fluid
Inductive proximity sensors, OsiSense XS ................................................................................ 20 to 30
Detection without contact of metal objects
Capacitive proximity sensors, OsiSense XT ...................................................................................... 31
Detection of insulating materials or conductive materials
Photo-electric sensors, OsiSense XU ............................................................................................ 32 to 43
Detection without contact of any object
Ultrasonic sensors, OsiSense XX ..................................................................................................... 44 to 46
Detection without contact of any object of any material
Cabling system, OsiSense XZ ...................................................................................................................... 47
Pre-wired female connectors
Rotary encoders, OsiSense XCC .................................................................................................... 48 and 49
Opto-electronic detection
Radio frequency identification, OsiSense XG ...................................................................... 50 and 51
13.56 MHz RFID detection
Sensors for Safety, Preventa products ........................................................................................... 52 to 67
Sensors for explosive atmospheres, ATEX products ......................................................... 68 to 81
1
2
Telemecanique Sensors
Simply easy!™
• Safety switches
◄
Preventa™ XUSL , the new safety Light Curtains, for an efficient protection of machine operators, for finger, hand and body
Preventa™ XY2CJ , the emergency stop rope pull switches. A solution easy to reach and trigger from everywhere in the work zone
►
• Pressure sensors
◄
Easily control machine pressure with the new
OsiSense™ XMLR , the intuitive pressure switch that combines high performance and maximum ease of use.
OsiSense™ ZMLP , the simple switch with display that can be linked to a separate pressure transmitter, delivering a clear view of accurate pressure information even if the conduit runs in a hard to access location.
►
Other versions: please consult our Customer Care Centre.
• Radio Frequency Identification (RFID)
◄
The OsiSense™ XG identification system makes it possible to perform object traceability, identification (tracking) and access control functions.
The new Ethernet smart antenna
OsiSense™ XGCS850C201 enables up to 32 smart antennas to be daisy-chained.
• Photo Electric sensors
◄
Osisense™ XUY Roller Sensors, to be easily and fully integrated into your rollers conveyors system.
New shape and easier fixation making it more adaptable for any case.
OsiSense™ XUK8T™ compact
►
photo-electric laser sensor enabling reliable detection with high accuracy background suppression long distance, and for distance measurement, using "Time of Flight"
(light velocity) (launch Q3 2014).
◄
OsiSense™ XUVU , the new ultrasonic Fork thru-beam for detection of transparent labels
OsiSense™ XUX9ARCNT16 , a reliable photo electric sensor specially designed to detect proximity between two traveling overhead cranes "anti-collision". A strong red beam is highly visible on the reflector to allow easy and fast setting.
►
Other versions: please consult our Customer Care Centre.
3
OsiSense XC Limit switches
Compact and miniature, complete switches
(variable composition, see pages 6-7)
XCMD
GN-YE
2-pole contact
NC+NO snap action
GN-YE
2-pole contact
NC+NO slow break
XCKT
2-pole contact
NC+NO snap action
Miniature XCMD metal, pre-cabled; fixing by the body or by the head
Type of operator Metal end plunger
Steel roller plunger
Thermoplastic roller lever
Steel roller lever
Variable length thermoplastic roller lever
M12 head metal end plunger
Mechanical durability (millions of operating cycles)
Actuation speed (in m/s)
10
0.5
10
0.5
10
1.5
10
1.5
10
1.5
10
0.5
Switches conforming to standard IEC 947-5-1 section 3
Product certification
Degree of protection conforming to IEC 60529
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Fixing centres (mm)
Body dimensions (mm) W x D x H
Connection Cable
Complete switch 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
Connector
CE - UL - CSA - CCC
IP 66 and IP 67
AC-15; B300 (Ue = 240 V, Ie = 1.5 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)
20
30 x 16 x 50
Pre-cabled, adjustable direction, length = 1 m (other lengths available on request)
M12 x 1
XCMD2110L1 XCMD2102L1 XCMD2115L1 XCMD2116L1 XCMD2145L1 XCMD21F0L1
XCMD2510L1 XCMD2502L1 XCMD2515L1 XCMD2516L1 XCMD2545L1 XCMD25F0L1
M12
Complete switch NC+NO snap action (M12-5 pins) XCMD2110C12 XCMD2102C12 XCMD2115C12 XCMD2116C12 XCMD2145C12 XCMD21F0C12
1C/O snap action (M12-4 pins) (1) XCMD2110M12 XCMD2102M12 XCMD2115M12 XCMD2116M12 XCMD2145M12 XCMD21F0M12
(1) Although their design is identical to the pre-cabled switches, the switches incorporating an M12 4-pin connector cannot be marked with the symbol because they are single-pole C/O.
Positive opening operation.
ISO entry
(to EN 50262)
XCKP/XCKD
2-pole contact
NC+NO snap action
2-pole contact
NC+NO slow break
Positive opening operation.
Compact XCKD metal and XCKP plastic conforming to standard EN 50047
Type of operator
Mechanical durability (millions of operating cycles)
Actuation speed (in m/s)
Switches conforming to standard IEC 947-5-1 section 3
Metal end plunger
15
0.5
Steel roller plunger
10
0.5
Thermoplastic roller lever plunger, horizontal actuation in 1 direction
15
1
M18 head metal end plunger
10
0.5
Product certification
Degree of protection conforming to IEC 60529
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Cable entry
Fixing centres (mm)
Body dimensions (mm) W x D x H
CE - CSA - CCC - GOST
IP 66 and IP 67
AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
1 tapped entry for ISO M16 x 1.5 cable gland (3) or M12 connector
20
31 x 30 x 65
20
Metal switches
Complete switch 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
2-pole NC+NO snap action (M12-5 pins)
XCKD2110P16
XCKD2510P16
XCKD2110M12
XCKD2102P16
XCKD2502P16
XCKD2102M12
Plastic, double insulated switches
Complete switch 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
XCKP2110P16
XCKP2510P16
XCKP2102P16
XCKP2502P16
2-pole NC+NO snap action (M12-4 pins) XCKP2110M12 XCKP2102M12
(3) For Pg 11 cable entries, replace P16 by G11. Example: XCKD2110 P16 becomes XCKD2110G11.
For other cable entries, see customised assembly on page 7.
20
XCKD2121P16
XCKD2521P16
XCKD2121M12
XCKP2121P16
XCKP2521P16
XCKP2121M12
M18 x 1
XCKD21H0P16
XCKD25H0P16
XCKD21H0M12
XCKP21H0P16
XCKP25H0P16
XCKP21H0M12
M18 head steel roller plunger
10
0.5
M18 x 1
XCKD21H2P16
XCKD25H2P16
XCKD21H2M12
XCKP21H2P16
XCKP25H2P16
XCKP21H2M12
Other versions: please consult our Customer Care Centre.
4
ISO entry
(to EN 50262)
10
0,5
Retractable steel roller lever plunger
M12 head steel roller plunger
10
0.1
20
XCMD2124L1
XCMD2524L1
M12 x 1
XCMD21F2L1
XCMD25F2L1
“Cat’s whisker”
5
1
–
20
XCMD2106L1
XCMD2506L1
XCMD2124C12
XCMD2124M12
XCMD21F2C12 XCMD2106C12
XCMD21F2M12 XCMD2106M12
Compact XCKT plastic, 2 cable entries
Metal end plunger
Steel roller plunger
Thermoplastic roller lever
Variable length thermoplastic roller lever
15
0.5
10
0.5
10
1.5
15
1
CE - CSA - CCC - GOST
IP 66 and IP 67
AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
20 or 40
58 x 30 x 51
2 tapped entries for ISO M16 x 1.5 cable gland (2)
XCKT2110P16
–
XCKT2102P16
–
XCKT2118P16
–
XCKT2145P16
–
Thermoplastic roller lever plunger, horizontal actuation in 1 direction
5
1
–
XCKT2121P16
–
“Cat’s whisker”
5
1
–
XCKT2106P16
–
–
–
–
–
–
–
–
–
–
–
(2) For Pg 11 cable entries, replace P16 by G11. Example: XCKT2110 P16 becomes XCKT2110G11.
–
–
ISO entry
(to EN 50262)
Compact XCKD metal and XCKP plastic conforming to standard EN 50047
Type of operator
Mechanical durability (millions of operating cycles)
Actuation speed (in m/s)
Switches conforming to standard IEC 947-5-1 section 3
Metal end plunger
15
0.5
Steel roller plunger
10
0.5
Thermoplastic roller lever plunger, horizontal actuation in 1 direction
15
1
M18 head metal end plunger
10
0.5
Product certification
Degree of protection conforming to IEC 60529
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Cable entry
Fixing centres (mm)
Body dimensions (mm) W x D x H
CE - CSA - CCC - GOST
IP 66 and IP 67
AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
1 tapped entry for ISO M16 x 1.5 cable gland (3) or M12 connector
20
31 x 30 x 65
20
Metal switches
Complete switch 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
2-pole NC+NO snap action (M12-5 pins)
XCKD2110P16
XCKD2510P16
XCKD2110M12
XCKD2102P16
XCKD2502P16
XCKD2102M12
Plastic, double insulated switches
Complete switch 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
XCKP2110P16
XCKP2510P16
XCKP2102P16
XCKP2502P16
2-pole NC+NO snap action (M12-4 pins) XCKP2110M12 XCKP2102M12
(3) For Pg 11 cable entries, replace P16 by G11. Example: XCKD2110 P16 becomes XCKD2110G11.
For other cable entries, see customised assembly on page 7.
20
XCKD2121P16
XCKD2521P16
XCKD2121M12
XCKP2121P16
XCKP2521P16
XCKP2121M12
M18 x 1
XCKD21H0P16
XCKD25H0P16
XCKD21H0M12
XCKP21H0P16
XCKP25H0P16
XCKP21H0M12
M18 head steel roller plunger
10
0.5
M18 x 1
XCKD21H2P16
XCKD25H2P16
XCKD21H2M12
XCKP21H2P16
XCKP25H2P16
XCKP21H2M12
Thermoplastic roller lever
10
1.5
Variable length
Thermoplastic roller lever
10
1.5
Thermoplastic roller lever
Ø 50 mm
10
1.5
“Cat’s whisker”
5
1
–
Application - XCPR and XCDR with manual reset
Metal end plunger
1
0.5
Steel roller plunger
1
0.5
Thermoplastic roller lever plunger, horizontal actuation in 1 direction
1
1
Thermoplastic roller lever plunger, vertical actuation in 1 direction
1
1
Thermoplastic roller lever
1
1.5
20 20 20 20
CE - CSA - CCC - GOST
IP 66 and IP 67
AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
1 tapped entry for ISO M20 x 1.5 cable gland (4)
20
31 x 30 x 95
20 20 20 20
XCKD2118P16
XCKD2518P16
XCKD2118M12
XCKD2145P16
XCKD2545P16
XCKD2145M12
XCKD2139P16
XCKD2539P16
XCKD2139M12
XCKD2106P16
XCKD2506P16
XCKD2106M12
XCDR2110P20
XCDR2510P20
–
XCDR2102P20
XCDR2502P20
–
XCKP2118P16
XCKP2518P16
XCKP2145P16
XCKP2545P16
XCKP2139P16
XCKP2539P16
XCKP2106P16
XCKP2506P16
XCPR2110P20
XCPR2510P20
XCPR2102P20
XCPR2502P20
XCKP2118M12 XCKP2145M12 XCKP2139M12 XCKP2106M12 – –
(4) For Pg 13.5 cable entries, replace P20 by G13. Example: XCDR2110 P20 becomes XCDR2110G13.
For other cable entries, see customised assembly on page 7.
XCDR2121P20
XCDR2521P20
–
XCPR2121P20
XCPR2521P20
–
XCDR2127P20
XCDR2527P20
–
XCPR2127P20
XCPR2527P20
–
XCDR2118P20
XCDR2518P20
–
XCPR2118P20
XCPR2518P20
–
Other versions: please consult our Customer Care Centre.
5
OsiSense XC Limit switches
Customised assembly of miniature and compact switches
Heads - common to miniature and compact bodies
Metal plunger and multi-directional heads
Description Metal end plunger
Metal end plunger with protective elastomer boot
Steel roller plunger
Retractable steel roller lever plunger
Thermoplastic roller lever plunger, horizontal actuation
Reference ZCE10
Metal rotary heads and levers
Description Rotary head without lever, spring return, for actuation from
LH and RH side
ZCE11 ZCE02 ZCE24 (2) ZCE21
Thermoplastic roller lever, track:
24/31 mm (ZCMD)
29/36 mm (ZCD/P/T)
Steel roller lever, track:
24/31 mm (ZCMD)
29/36 mm (ZCD/P/T)
Thermoplastic roller lever, track:
16/39 mm (ZCMD)
21/44 mm (ZCD/P/T)
Steel roller lever, track:
16/39 mm (ZCMD)
21/44 mm (ZCD/P/T)
Bodies
Reference
Miniature
ZCE01 ZCY15 (2) ZCY16 (2) ZCY25 (2) ZCY25 (2)
(1) Recommended for use with bodies: ZCD... / ZCP... / ZCT... (2) Recommended for use with bodies: ZCMD...
6
Type of contact
GN-YE GN-YE GN-YE GN-YE GN-YE
GN-YE
2-pole
NO+NC
Snap action
3-pole
2NC+1NO
Snap action
2-pole
NC+NO
Slow break
3-pole
2NC+1NO
Slow break
2-pole
NO+NC
Snap action
2-pole
NC+NO
Snap action
Connector 5 pin
1-pole
1C/O
Snap action
Connector 4 pin
4-pole
2NC+2NO
Snap action
Reference of metal body
Cable L = 1 m
L = 2 m
L = 5 m
ZCMD21
–
–
–
ZCMD39
–
–
–
ZCMD25
–
–
–
ZCMD37
–
–
–
– ZCMD21C12 ZCMD21M12 –
ZCMD21L1 (3) – – ZCMD41L1
ZCMD21L2 (3) –
ZCMD21L5 (3) –
(3) For contact 2-pole NC+NO slow break, replace 21 by 25. Example: ZCMD 21L1 becomes ZCMD25L1
–
–
ZCMD41L2
ZCMD41L5
Connection of miniature bodies
Specific pre-cabled connection components
Option: PUR pre-wired
M12 connector, L = 2 m (1)
5-pin 4-pin
L = 1 m
L = 2 m
L = 5 m for
ZCMD21 for
ZCMD39 for
ZCMD25 for
ZCMD37
ZCMC21L1 ZCMC39L1 ZCMC25L1 ZCMC37L1
ZCMC21L2 ZCMC39L2 ZCMC25L2 ZCMC37L2
ZCMC21L5 ZCMC39L5 ZCMC25L5 ZCMC37L5
Positive opening operation.
XZCP1164L2 XZCP1141L2
(1) For PVC cable see page 47
Other versions: please consult our Customer Care Centre.
Heads - common to miniature and compact bodies
Limit switches
Customised assembly of miniature and compact switches
Thermoplastic roller lever plunger, vertical actuation
M12 head metal end plunger
M18 head metal end plunger
M12 head steel roller plunger
M18 head steel roller plunger
Spring rod Spring rod with plastic end
“Cat’s whisker”
Reference ZCE10 ZCE11 ZCE02 ZCE24 (2) ZCE21 ZCE27 ZCEF0(2) ZCEH0(1)
Thermoplastic roller lever, track:
20/36 mm (ZCMD)
24/40 mm (ZCD/P/T)
Steel roller lever, track:
20/36 mm (ZCMD)
24/40 mm (ZCD/P/T)
Ceramic roller lever
ZCEF2(2)
Variable length thermoplastic roller lever
ZCEH2(1)
Round, glass fibre rod lever
Ø 3 mm
L = 125 mm
ZCE08
Metal spring-rod lever
ZCE07
Thermoplastic roller lever
Ø 50 mm
ZCE06
Adjustable thermoplastic roller lever
Ø 50 mm
Bodies
Reference ZCE01 ZCY15 (2) ZCY16 (2) ZCY25 (2) ZCY25 (2) ZCY18(1)
Compact
ZCY19(1) ZCY22 ZCY45 ZCY55 ZCY91 ZCY39 ZCY49
Type of contact
Ref. metal body
Connection of compact bodies
Interchangeable outlet for cable gland
Description
Metal
Plastic
2-pole NC+NO
Snap action
ZCD21
Ref. plastic body ZCP21
3-pole
2NC+1NO
Snap action
ZCD39
ZCP39
2-pole NC+NO
Slow break
ZCD25
ZCP25
2-pole NC+NC
Slow break
ZCD27
ZCP27
For ISO M16 For ISO M20 For Pg 11 cable gland cable gland cable gland
ZCDEP16
ZCPEP16
ZCDEP20
ZCPEP20
ZCDEG11
ZCPEG11
2-pole NO+NO
Slow break
ZCD28
ZCP28
For Pg 13.5
cable gland
ZCDEG13
ZCPEG13
2-pole NC+NC
Snap action
ZCD29
ZCP29
3-pole
2NC+1NO
Slow break
ZCD37
ZCP37
2-pole NC+NO - Snap action
Connector
5-pin
ZCD21M12
–
Connector
4-pin
–
ZCP21M12
Option: PUR pre-wired M12 connector, L = 2 m (1)
5-pin 4-pin
For 1/2" NPT For PF 1/2 (G12) cable gland cable gland
ZCDEN12
ZCPEN12
ZCDEF12
ZCPEF12 XZCP1164L2 XZCP1141L2
(1) For PVC cable see page 47
2-pole NC+NO
Snap action
–
2-pole NC+NO
Slow break
–
ZCT21P16 (2) ZCT25P16 (2)
(2)
ZCT Pg 11 cable gland versions: replace the suffix P16 by G11.
Example:
ZCT21 P16 becomes ZCT21G11
ZCT 1/2" NPT versions: replace the suffix P16 by
N12 (adaptor).
Example:
ZCT21 P16 becomes ZCT21N12
1 Cable entry 1/2" NPT
1 Cable entry Pg11
Other versions: please consult our Customer Care Centre.
7
OsiSense XC Limit switches
Classic - XCKM, XCKL, complete switches
ISO entry
(to EN 50262)
XCKM
2-pole contact
NC+NO snap action
2-pole contact
NC+NO slow break
3-pole contact
2NC+1NO snap action
Type XCKM metal, 3 cable entries, XCKL metal, 1 cable entry
Type of operator
Mechanical durability (millions of operating cycles)
Actuation speed (in m/s)
Product certification
Degree of protection conforming to IEC 60529
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Cable entry (1) XCKM
XCKL
Fixing centres (mm)
Body dimensions (mm) W x D x H XCKM / XCKL
Metal end plunger
Steel roller plunger
Roller lever plunger, horizontal actuation
20
0.5
20
0.5
in 1 direction
20
1.5
CE - UL - CSA - CCC - GOST - C-TICK - BV
Thermoplastic roller lever
15
1.5
IP 665
AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
3 tapped entries for ISO M20 x 1.5 cable gland (2 entries fitted with blanking plugs)
1 cable entry with cable gland
41
64 x 30 x 64 / 52 x 30 x 72
“Cat’s whisker”
10
0.5
Complete switch XCKM
2-pole NC+NO snap action
2-pole NC+NO, break before make, slow break
XCKM110H29
XCKM510H29
XCKM102H29
XCKM502H29
Complete switch XCKL
2-pole NC+NO snap action XCKL110 XCKL102
(1) For Pg 11 cable entries delete the reference suffix H29. Example: XCKM110 H29 becomes XCKM110.
Positive opening operation.
XCKM121H29
XCKM521H29
XCKL121
XCKM115H29
XCKM515H29
XCKM106H29
–
XCKL115 XCKL106
Classic - XCKM, XCKL,
Customised assembly - Body/contact sub-assemblies
Type XCKM metal, 3 cable entries
Type of contact
2-pole
NC+NO snap action
Reference of body with contact block
XCKL reference of body with contact block (2)
Reference of contact block only
(2) For cable entry 1/2" NPT, add H7. Example: XCKL1 becomes XCKL1 H7
ZCKM1H29
ZCKL1
XE2SP2151
8
2-pole
NC+NO slow break
ZCKM5H29
ZCKL5
XE2NP2151
3-pole
2NC+1NO snap action
–
ZCKMD39H29
XE3SP2141
3-pole
2NC+1NO slow break
–
ZCKMD37H29
XE3NP2141
Other versions: please consult our Customer Care Centre.
Operating heads, complete or for customer assembly
Complete switch
Rotary or multi-directional heads metal head with thermoplastic roller lever
=
Body/contact assembly metal head with steel roller lever
+
Head
+ with variable length thermoplastic roller lever (2) with Ø 6 mm thermoplastic rod
L = 200 mm (3) with thermoplastic roller lever (3) for actuation from left AND right or left OR right with “Cat’s whisker”
Lever with spring rod
Plunger heads
Reference ZCKD15 ZCKD16 ZCKD41 ZCKD59 ZCKD31 ZCKD06 with metal end plunger with metal end plunger and protective boot with steel roller plunger with steel roller plunger and protective boot with thermoplastic roller lever plunger, horizontal actuation in 1 direction with steel roller lever plunger, horizontal actuation in 1 direction
ZCKD08
Reference
ZCKD10 ZCKD109 ZCKD02 ZCKD029 ZCKD21 ZCKD23
Rotary heads and separate levers spring return, for actuation from left AND right or left OR right lever with thermoplastic roller (2) lever with steel roller (2) variable length lever with thermoplastic roller (2) variable length lever with steel roller (2) rod, Ø 6 mm thermoplastic
L = 200 mm (3)
Reference ZCKD05 ZCKY31
(2) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
(3) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.
ZCKY33 ZCKY41 ZCKY43 ZCKY59
Other versions: please consult our Customer Care Centre.
9
OsiSense XC Limit switches
Industrial - XCKJ, complete switches
ISO entry
(to EN 50262)
XCKJ
2-pole contact
NC+NO snap action
2-pole contact
NC+NO slow break
3-pole contact
2NC+1NO snap action
Type XCKJ metal, fixed body, conforming to standard EN 50041
Type of operator
Mechanical durability (millions of operating cycles)
Actuation speed (in m/s)
Product certification
Degree of protection conforming to IEC 60529
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Cable entry (1)
Fixing centres (mm)
Body dimensions (mm) W x D x H
Metal end plunger
Steel roller plunger
Thermoplastic roller lever
Steel roller lever
30
0.5
25
1
30
1.5
CE - UL - CSA - CCC - GOST - C-TICK - BV
IP 667
30
1,5
AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
1 tapped entry for ISO M20 x 1.5 cable gland
30 x 60
40 x 44 x 77
Variable length thermoplastic roller lever
30
1.5
Polyamide Ø 6 mm rod lever
L = 200 mm
30
1.5
Complete switch M20 2-pole NC+NO snap action XCKJ161H29 XCKJ167H29
2-pole NC+NO break before make, slow break XCKJ561H29 XCKJ567H29
1/2" NPT 2-pole NC+NO snap action XCKJ161H7 XCKJ167H7
M12 5P 2-pole NC+NO snap action XCKJ161D XCKJ167D
(1) For Pg 13.5 cable entry delete the reference suffix H29. Example: XCKJ161 H29 becomes XCKJ161.
Positive opening operation.
XCKJ10511H29
XCKJ50511H29
XCKJ10513H29 XCKJ10541H29
XCKJ50513H29 XCKJ50541H29
XCKJ10559H29
XCKJ50559H29
XCKJ10511H7 XCKJ10513H7 XCKJ10541H7 XCKJ10559H7
XCKJ10511D XCKJ10513D XCKJ10541D XCKJ10559D
Industrial - XCKJ,
Customised assembly - Body/contact sub-assemblies
Type XCKJ metal, 1 cable entry
Type of contact
Cable entry (1)
Reference of body with contact block
Reference of contact block only
10
M20
Pg13
1/2" NPT
M12 (5 pin)
2-pole
NC+NO snap action
2-pole
NC+NO slow break
1 tapped entry for ISO M20 x 1.5 cable gland
2 C/O snap action
Simultaneous
ZCKJ1H29
ZCKJ1
ZCKJ1H7
ZCKJ1D
XE2SP2151
ZCKJ5H29
ZCKJ5
ZCKJ5H7
ZCKJ5D
XE2NP2151
ZCKJ2H29
ZCKJ2
ZCKJ2H7
–
–
3-pole
2NC+1NO snap action
–
–
–
ZCKJD39H29
XE3SP2141
3-pole
2NC+1NO slow break
–
–
–
ZCKJD37H29
XE3NP2141
Other versions: please consult our Customer Care Centre.
Operating heads, complete or for customer assembly
Complete switch
Plunger or multi-directional heads with reinforced steel roller end plunger
=
Body/contact assembly
+
Head
+
Lever with metal end plunger with thermoplastic roller lever plunger,
1 direct. of actuation with steel roller lever plunger,
1 direct. of actuation with steel roller end plunger with steel ball bearing end plunger
End steel roller plunger with protective boot
Reference ZCKE67 ZCKE61 ZCKE21 ZCKE23 ZCKE62 with metal side plunger
Side steel roller plunger, horizontal
Side steel roller plunger, vertical with spring rod with “Cat’s whisker”
ZCKE66 ZCKE629
Reference ZCKE63 ZCKE64 ZCKE65 ZCKE08 ZCKE06
Separate rotary heads and levers spring return for actuation from left AND right or left OR right lever with thermoplastic roller (2) lever with steel roller (2) variable length lever with thermoplastic roller (2) variable length lever with steel roller (2) rod, Ø 6 mm thermoplastic
L = 200 mm (2) square rod lever, steel, U 3 mm
L = 125 mm (2) round rod lever, steel, Ø 3 mm
L = 125 mm (2) spring lever with thermoplastic end (3) spring-metal rod lever
(3)
Reference ZCKE05 ZCKY11 stay put for actuation from left AND right
ZCKY13 ZCKY41 ZCKY43 forked arm lever with thermoplastic rollers, 1 track (2)
ZCKY59 ZCKY51 forked arm lever with thermoplastic rollers, 2 track (2)
ZCKY53 ZCKY81 ZCKY91
Reference ZCKE09 ZCKY71
(2) Adjustable throughout 360° in 5° steps, or in 45° steps by reversing the lever mounting.
(3) Adjustable throughout 360° in 5° steps, or in 90° steps by reversing the notched washer.
ZCKY61
Other versions: please consult our Customer Care Centre.
11
OsiSense XC
XCKS XCKMR
2-pole contact
NC+NO snap action
2-pole contact
NC+NO slow break
3-pole
2NC+1NO snap action
XCR
2 x 2-pole contacts
NC+NC staggered, slow break
2 x 2-pole contacts, snap action
Limit switches
Classic - XCKS, complete switches
ISO entry
(to EN 50262)
Type XCKS plastic, double insulated, conforming to standard EN 50041
Type of operator Metal end plunger
Steel roller plunger
Thermoplastic roller lever
Variable length thermoplastic roller lever
20
Rubber roller lever
Ø 50 mm
20 Mechanical durability (millions of operating cycles) 25 15 20
Actuation speed (in m/s)
Product certification
0.5
0.5
CE - UL - CSA - CCC - GOST - C-TICK
1.5
1.5
1
Degree of protection conforming to IEC 60529 IP 653
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
Cable entry 1 tapped entry for ISO M20 x 1.5 cable gland (1)
Polyamide Ø 6 mm rod lever
L = 200 mm
20
1
Fixing centres (mm)
Body dimensions (mm) W x D x H
30 x 60
40 x 36 x 72.5
Complete switch 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
Body 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
3-pole 2NC+1NO snap action
Associated head (including operator)
Operating lever for rotary head
Complete switch Snap-action 2-pole 2X (1 NC + 1 NO) contact
Both contacts act in each direction of actuation
1 contact operates in each direction
Complete switch 2 C/O staggered snap action contacts
2 x 2 pole NC+NC staggered, slow break contacts
Positive opening operation.
–
–
–
–
–
XCKS101H29
XCKS501H29
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD01
–
–
–
–
–
XCKS102H29
XCKS502H29
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD02
–
–
–
–
XCKS131H29 XCKS141H29
XCKS531H29 XCKS541H29
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD31
ZCKY31
ZCKSD39H29
ZCKD41
ZCKY41
–
–
–
–
ZCKS1H29
ZCKS5H29
XCKS139H29
XCKS539H29
–
–
–
–
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD39
ZCKY39
XCKS159H29
XCKS559H29
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD59
ZCKY59
–
–
–
–
(1) For Pg 13.5 cable entry delete the reference suffix H29. Example: XCKJ161 H29 becomes XCKJ161.
For severe applications - XC2J,
Customised assembly - Body/contact sub-assemblies
Type XC2J metal, fixed body, 1 cable entry incorporating cable gland
Type of contact
Reference of body with contact block
Reference of contact block only
12
Single-pole
1 C/O contact
snap action
ZC2JC1
XCKZ01
Double-pole
2 C/O simultaneous contacts snap action
ZC2JC2
XESP1021
Other versions: please consult our Customer Care Centre.
Severe duty for hoisting and materials handling applications
XCKMR and XCR, complete switches
ISO entry
(to EN 50262)
Type XCKS plastic, double insulated, conforming to standard EN 50041
Type of operator Metal end plunger
Steel roller plunger
Thermoplastic roller lever
Variable length thermoplastic roller lever
20
Rubber roller lever
Ø 50 mm
20 Mechanical durability (millions of operating cycles) 25 15 20
Actuation speed (in m/s)
Product certification
0.5
0.5
CE - UL - CSA - CCC - GOST - C-TICK
1.5
1.5
1
Degree of protection conforming to IEC 60529 IP 653
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
Cable entry 1 tapped entry for ISO M20 x 1.5 cable gland (1)
Polyamide Ø 6 mm rod lever
L = 200 mm
20
1
Fixing centres (mm)
Body dimensions (mm) W x D x H
30 x 60
40 x 36 x 72.5
Complete switch 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
Body 2-pole NC+NO snap action
2-pole NC+NO break before make, slow break
3-pole 2NC+1NO snap action
Associated head (including operator)
Operating lever for rotary head
Complete switch Snap-action 2-pole 2X (1 NC + 1 NO) contact
Both contacts act in each direction of actuation
1 contact operates in each direction
Complete switch 2 C/O staggered snap action contacts
2 x 2 pole NC+NC staggered, slow break contacts
Positive opening operation.
–
–
–
–
–
XCKS101H29
XCKS501H29
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD01
–
–
–
–
–
XCKS102H29
XCKS502H29
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD02
–
–
–
–
XCKS131H29 XCKS141H29
XCKS531H29 XCKS541H29
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD31
ZCKY31
ZCKSD39H29
ZCKD41
ZCKY41
–
–
–
–
ZCKS1H29
ZCKS5H29
XCKS139H29
XCKS539H29
–
–
–
–
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD39
ZCKY39
XCKS159H29
XCKS559H29
ZCKS1H29
ZCKS5H29
ZCKSD39H29
ZCKD59
ZCKY59
–
–
–
–
(1) For Pg 13.5 cable entry delete the reference suffix H29. Example: XCKJ161 H29 becomes XCKJ161.
For severe applications - XC2J,
Customised assembly - Body/contact sub-assemblies
–
–
–
–
–
–
–
Types XCKMR and XCR “Application - hoisting, materials handling, conveying”
Square rod levers
U
2
6 mm, “crossed”
Square rod levers
U
1
6 mm, “crossed”
Square rod lever
U
10
6 mm
Large roller rod lever
Ø 50 mm
10
Square rod levers Conveyor belt shift monitoring switches
U 6 mm, “crossed” or “T” Galvanised steel Stainless steel
10 operating lever
0.3
operating lever
0.3
1.5
CE - CSA - CCC - GOST
1.5
1.5
1.5
1.5
1.5
1.5
IP 66 IP 65 IP 54
AC-15; A300 (Ue = 240 V, Ie = 3 A) / DC-13; Q300 (Ue = 250 V, Ie = 0.27 A)
IP 66
1 tapped entry for n° 13 cable gland (for ISO M20 x 1.5, adaptor DE9RA1620 must be ordered separately) 3 x ISO M20 x 1.5 entries 1x ISO M20x1.5 entry & cable gland
61.5
118 x 59 x 77 116 x 66 x 77
85 x 75
85 x 75 x 95
105 x 70
85 x 87 x 146
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XCKMR54D1H29 (2)
(2) Steel rods, L = 200 mm
–
–
–
XCKVR54D1H29 (2)(5) –
XCRA11(2)
XCRB11(2)
–
XCRA15
–
(3) Steel “T” rods, L = 200 mm, W = 300 mm.
XCRE18(2)
XCRF17(3)
–
(4) Polyester enclosure²
–
–
XCRT115
–
(5) Plastic enclosure
–
–
XCRT315 (4)
–
Plunger heads with metal end plunger
Operating heads, complete or for customer assembly with steel roller end plunger
Type XC2J metal, fixed body, 1 cable entry incorporating cable gland
Type of contact
Reference of body with contact block
Reference of contact block only
Single-pole
1 C/O contact
snap action
ZC2JC1
XCKZ01
Reference ZC2JE61 ZC2JE62
Rotary heads and separate levers spring return spring return for actuation from left AND right for actuation from left OR right variable length lever with thermoplastic roller (1) rigid rod
3 mm, steel
L = 125 mm (1) lever with thermoplastic roller
(1) lever with steel roller (1) spring lever
(1) spring-rod lever
Double-pole
2 C/O simultaneous contacts snap action
ZC2JC2
XESP1021
Reference ZC2JE01 ry head (1) Adjustable throughout 360°.
ZC2JE05 ZC2JY31 ZC2JY51 ZC2JY11 ZC2JY13 ZC2JY81 ZC2JY91
Other versions: please consult our Customer Care Centre.
13
OsiSense XM Sensors for pressure control
Electronic sensors XMLK
Electrical connection by EN 175301-803-A connector, M12 connector
For pumping applications
Pressure range (bar) (1)
Fluids controlled
Ambient air temperature
Degree of protection (IEC 60529)
Product certification
Voltage limits
Dimensions (mm) Ø x L
Fluid connection (2)
Electrical connection (3)
Type of output (4)
0…6 air, fresh water
0…+ 80°C
0…10 0…16 0…25
IP 65
CE - UL - CSA
8…33 V DC for 4…20 mA, 16.2…33V DC for 0…10 V
36 x 67.5 (not including connector)
G 1/4 A (male)
EN 175301-803-A
4…20 mA, 2-wire technique, 0…10V, 3-wire technique
0…6 0…10 0…16 0…25
M12 3 pin male
Analogue output 4…20 mA XMLK006B2C21 XMLK010B2C21 XMLK016B2C21 XMLK025B2C21 XMLK006B2D21 XMLK010B2D21 XMLK016B2D21 XMLK025B2D21
0…10 V XMLK006B2C71 XMLK010B2C71 XMLK016B2C71 XMLK025B2C71 XMLK006B2D71 XMLK010B2D71 XMLK016B2D71 XMLK025B2D71
(1) Also available with psi range. (2) Also available with ¼”-18NPT male fluid entry.
(4) Other types of output; 0…5 V, 0…10 V, etc.
(3) Also available with 3 pin packard connector.
Available in bulk packs for selling in lots. Add TQ suffix to the reference, ex: XMLK006B2C21 becomes XMLK006B2C21TQ.
Electronic sensors XMLP
Electrical connection by EN 175301-803-A connector, M12 connector
AC)
For industrial applications
(hydraulic circuits, HV
Pressure range (bar) (1)
Fluids controlled
Ambient air temperature
0…10 0…16 0…25 0…40 0…100
Hydraulic oils, air, fresh water, gas, refrigeration fluids from -30…+120°C
- 30…+ 100°C
0…160 0…250 0…400
Degree of protection (IEC 60529)
Product certification
Voltage limits
Dimensions (mm) Ø x L
IP 65 (EN175301-803-A), IP 65, IP 67 and IP 69K (M12 connector)
CE cULus
8…30 V DC for 4…20 mA, 14…30V DC for 0…10 V
30 x 26 (not including connector)
Fluid connection (2)
Electrical connection (3)
G 1/4 A (male)
EN 175301-803-A, M12 4 pin connector
Type of output (4) 4…20 mA, 2-wire technique, 0…10V, 3-wire technique
Analogue output EN 175301-803-A XMLP010BC21V XMLP016BC21V XMLP025BC21V XMLP040BC21V XMLP100BC22 XMLP160BC22 XMLP250BC22 XMLP400BC22
4…20 mA
M12 connector XMLP010BD21V XMLP016BD21V XMLP025BD21V XMLP040BD21V XMLP100BD22 XMLP160BD22 XMLP250BD22 XMLP400BD22
Analogue output EN 175301-803-A XMLP010BC71V XMLP016BC71V XMLP025BC71V XMLP040BC71V XMLP100BC72 XMLP160BC72 XMLP250BC72 XMLP400BC72
0…10 V
M12 connector
(1) Also available with psi range.
XMLP010BD71V XMLP016BD71V XMLP025BD71V XMLP040BD71V XMLP100BD72 XMLP160BD72 XMLP250BD72 XMLP400BD72
(2) Also available with 7/16-20UNF male or female, ¼”-18NPT male fluid entry.
(4) Also available with 0,5...4,5V ratiometric output. Available in bulk packs for selling in lots. Add
(3) Also available with 3 pin packard connector.
Q suffix to the reference, ex: XMLP010BC21V becomes XMLP010BC21VQ.
Switch with display ZMLP
Only usable with 4-20mA analogue output pressure transmitter
Type of switching mode
Displayed value range
Degree of protection
Product certification
Power supply
Electrical connection
-
-
Analogue output Switching output
4…20 mA PNP
4…20 mA
NPN
2 PNP
2 NPN
Hysteresis
-14,5 to 6000 with 27 selectable value ranges
Windows
IP65, IP67, and IP69K
CE cULus
24VDC (17 to 33 VDC)
Input: M12 female, 4 pin. Output: M12 male, 4 pin
ZMLPA1P2SH
ZMLPA1N2SH
ZMLPA2P0SH
ZMLPA2N0SH -
-
ZMLPA1P2SW
ZMLPA1N2SW
14
Accessories
Quick fixing bracket
Horizontal plan
XMLPZLH01
Vertical plan or pipe
XMLPZLV01
Other versions: please consult our Customer Care Centre.
Electronic sensors XMLG
Electrical connection by M12 connector
Pressure range
(bar) (1)
Fluids controlled
Ambient air temperature
-1…0 0…1 0…6 0…10 0…16
Hydraulic oils, air, fresh water, corrosive fluids from -15…+125°C
- 15…+ 85°C
IP 66 and IP 67
0…25 0…100 0…250 0…400
Degree of protection
(conforming to IEC 60529)
Product certification
Voltage limits
Dimensions (mm) Ø x L
Fluid connection (2)
Electrical connection (3)
Type of output (4)
CE - UL - CSA - GOST
12…24 V DC, 8…33 V DC for 4…20 mA, 11.4…33V DC for 0…10 V
Ø 22.8 x 58 (not including connector)
G 1/4 A (male)
M12 connector
4…20 mA, 2-wire technique, 0…10V, 3-wire technique
Analogue output 4…20 mA XMLGM01D21 XMLG001D21 XMLG006D21 XMLG010D21 XMLG016D21 XMLG025D21 XMLG100D21 XMLG250D21 XMLG400D21
0…10 V XMLGM01D71 XMLG001D71 XMLG006D71 XMLG010D71 XMLG016D71 XMLG025D71 XMLG100D71 XMLG250D71 XMLG400D71
(1) For other pressure ranges consult our web site. (3) Also available with an integrated quick connection.
(4) Also available with pressure switch function (digital output).
(2) Also available with ¼”-18NPT male fluid entry.
Available in bulk packs for selling in lots. Add TQ suffix to the reference, ex: XMLGM01D21 becomes XMLGM01D21TQ.
Electronic sensors XMLR
Electronic + Display
Adjustable pressure range
(bar) (1)
Fluids controlled
Ambient air temperature
-1…0 0…1 0…2,5 0…10
Hydraulic oils, air, fresh water, refrigerant fluids
- 20…+ 80°C
Degree of protection (conforming to IEC 60529) IP65, IP67 conforming to EN/IEC 60529
Product certification cULus conforming to UL 61010-1
0…16 0…25 0…40 0…250 0…400
Voltage limits (V)
Dimensions (mm) H x W x D
Fluid connection (2)
Electrical connection
Configurable with 4-digit display
Analogue output 4...20 mA
Analogue + switching output 4...20 mA
PNP - NO/NC programmable 0...10 V
2 switching outputs PNP - NO/NC prog.
Analogue + 2 switching outputs 4...20 mA
Possible differential (bar) Min.
(pressure switches)
0...10 V
Max.
Maximum permissible accidental pressure
17...33 Vdc
93x41x42
G1/4A (female)
M12 connector 4 pin or 5 pin
88x41x42
XMLRM01G0T25 XMLR001G0T25 XMLR2D5G0T25 XMLR010G0T25 XMLR016G0T25 XMLR025G0T25 XMLR040G0T25 XMLR250G0T25 XMLR400G0T25
XMLRM01G0T75 XMLR001G0T75 XMLR2D5G0T75 XMLR010G0T75 XMLR016G0T75 XMLR025G0T75 XMLR040G0T75 XMLR250G0T75 XMLR400G0T75
XMLRM01G1P25 XMLR001G1P25 XMLR2D5G1P25 XMLR010G1P25 XMLR016G1P25 XMLR025G1P25 XMLR040G1P25 XMLR250G1P25 XMLR400G1P25
XMLRM01G1P75 XMLR001G1P75 XMLR2D5G1P75 XMLR010G1P75 XMLR016G1P75 XMLR025G1P75 XMLR040G1P75 XMLR250G1P75 XMLR400G1P75
XMLRM01G2P05 XMLR001G2P05 XMLR2D5G2P05 XMLR010G2P05 XMLR016G2P05 XMLR025G2P05 XMLR040G2P05 XMLR250G2P05 XMLR400G2P05
XMLRM01G2P25 XMLR010G2P25 XMLR040G2P25 XMLR250G2P25 XMLR400G2P25
0.03
0,08 0,3 0,48 0,8 1,2 7,5 12
0.95
3
(1) For other pressure ranges consult our web site.
7,5
2,38
12
9,5
40
15
62
(2) Also available with ¼”-18NPT female fluid entry.
23,8
100
38
150
238
750
380
1200
Suitable female plug-in connectors
PUR Pre-wired connectors, L = 5 m (without LED) (5)
(5) For PVC cable see page 47
Other connectors elbowed
XZCP1241L5 straight
XZCP1141L5
Screw terminal EN 175301-803-A
4 pins XZCC12FCM40B
5 pins XZCC12FCM50B
XZCC43FCP40B
Other versions: please consult our Customer Care Centre.
15
OsiSense XM
ISO entry
(to EN 50262)
Sensors for pressure control
Electromechanical pressure and vacuum switches
XMLA and B
1 C/O single-pole contact, snap action
Size (bar) -1 5 1 2.5
Environmental characteristics
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Product certification
Fluid connection
Electrical connection
Ambient air temperature (°C): - 25…+ 70 Degree of protection (conforming to IEC 60529): IP 66
AC-15; B300 (Ue = 240 V, Ie = 1.5 A - Ue = 120 V, Ie = 3 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)
CE - UL - CSA - CCC - BV - LROS - RINA - GL - DNV - VIT-SEPRO - GOST
G 1/4" (female) (other connections possible, please consult us)
Screw terminals (1), tapped entry for ISO M20 x 1.5 cable gland - For n° 13 (DIN Pg 13.5) cable gland
Fluids controlled Hydraulic oils, fresh water, air up to 70°C
Type XMLA - fixed differential, single threshold detection
Setting range (bar) of upper limit (PH): pressure switches -0.28…-1 (4) –
Dimensions (mm) H x W x D 113 x 35 x 75 113 x 35 x 75
With setting scale
Natural differential (bar) subtract from PH to give PB
1 C/O single-pole, snap action contact at low setting at high setting
XMLAM01V2S12
0.24 (2)
0.24 (2)
–
–
–
Hydraulic oils, air up to 160°C
0.03…1
162 x 110 x 110
XMLA001R2S12
0.02
0.04
Hydraulic oils, fresh water, air up to 70°C
0.15…2.5
158 x 55 x 77.5
XMLA002A2S12
0.13
0.13
Type XMLB - adjustable differential, regulation between 2 thresholds
Setting range (bar) of upper limit (PH): pressure switches
With setting scale 1 C/O single-pole, snap action contact
Possible differential (bar) Min. at low setting
-0.14...-1 (4)
XMLBM02V2S12
0.13 (3)
-0.5...5
XMLBM05A2S12
0.5
subtract from PH to give PB Min. at high setting
Max. at high setting
0.13 (3)
0.8 (3)
0.5
6
0.05...1
XMLB001R2S12
0.04
0.06
0.75
0.3...2.5
XMLB002A2S12
0.16
0.21
1.75
XMLC and D
XMLC ISO entry
(to EN 50262)
2 C/O single-pole contacts, simultaneous snap action
XMLD
2 C/O single-pole contacts, snap action
(1 per stage)
Fluids controlled Hydraulic oils, fresh water, air up to 70°C
Type XMLC - adjustable differential, regulation between 2 thresholds
Setting range (bar) of upper limit (PH): pressure switches
Dimensions (mm) H x W x D
-0.14...-1 (4)
113 x 46 x 85
With setting scale
Possible differential (bar) subtract from PH to give PB
2 C/O single-pole, snap action contacts
Min. at low setting
Min. at high setting
Max. at high setting
XMLCM02V2S12
0.13 (4)
0.14 (4)
0.8 (4)
Hydraulic oils, air up to 160°C
0.05...1
175 x 110 x 110
XMLC001R2S12
0.03
0.04
0.8
Type XMLD - fixed differential, dual stage, for detection at each threshold
Setting range
(bar)
2
1 nd st
stage switching point (PB2)
stage switching point (PB1)
-0.12...-1 (4)
-0.10...-0.98
Spread between 2 stages (PB2 – PB1) -0.02...-0.88
Without setting scale 2 C/O single-pole, snap action contacts (1 per stage) XMLDM02V1S12
Natural differential (bar) subtract from PH 1/2 to give PB 1/2 at low setting at high setting
0.1 (2)
0.1 (2)
0.12...1
0.04...0.92
0.08...0.73
XMLD001R1S12
0.03
0.07
Hydraulic oils, fresh water, air up to 160°C
0.3...2.5
158 x 55 x 90
XMLC002B2S12
0.13
0.17
2
0.34...2.5
0.2...2.36
0.14...1.5
XMLD002B1S12
0.14
0.19
Other versions: please consult our Customer Care Centre.
16
Size (bar) -1 5 1 2.5
Environmental characteristics
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Product certification
Fluid connection
Electrical connection
Ambient air temperature (°C): - 25…+ 70 Degree of protection (conforming to IEC 60529): IP 66
AC-15; B300 (Ue = 240 V, Ie = 1.5 A - Ue = 120 V, Ie = 3 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)
CE - UL - CSA - CCC - BV - LROS - RINA - GL - DNV - VIT-SEPRO - GOST
G 1/4" (female) (other connections possible, please consult us)
Screw terminals (1), tapped entry for ISO M20 x 1.5 cable gland - For n° 13 (DIN Pg 13.5) cable gland
Fluids controlled Hydraulic oils, fresh water, air up to 70°C
Type XMLA - fixed differential, single threshold detection
Setting range (bar) of upper limit (PH): pressure switches -0.28…-1 (4) –
Dimensions (mm) H x W x D 113 x 35 x 75 113 x 35 x 75
With setting scale
Natural differential (bar) subtract from PH to give PB
1 C/O single-pole, snap action contact at low setting at high setting
XMLAM01V2S12
0.24 (2)
0.24 (2)
–
–
–
Hydraulic oils, air up to 160°C
0.03…1
162 x 110 x 110
XMLA001R2S12
0.02
0.04
Hydraulic oils, fresh water, air up to 70°C
0.15…2.5
158 x 55 x 77.5
XMLA002A2S12
0.13
0.13
Type XMLB - adjustable differential, regulation between 2 thresholds
Setting range (bar) of upper limit (PH): pressure switches
With setting scale 1 C/O single-pole, snap action contact
Possible differential (bar) Min. at low setting
-0.14...-1 (4)
XMLBM02V2S12
0.13 (3)
-0.5...5
XMLBM05A2S12
0.5
subtract from PH to give PB Min. at high setting
Max. at high setting
0.13 (3)
0.8 (3)
0.5
6
0.05...1
XMLB001R2S12
0.04
0.06
0.75
0.3...2.5
XMLB002A2S12
0.16
0.21
1.75
XMLC and D
4 10 20 conforming to IEC 947-5-1 Appendix A, EN 60 947-5-1
35 70 160 300 500
tapped entry, replace the last number of the reference (2) by 1 (example: XMLA010A2S12 becomes XMLA010A2S11)
Hydraulic oils, fresh water, air up to 70°C
Hydraulic oils up to 160°C
0.4…4
113 x 35 x 75
XMLA004A2S12
0.35
0.35
0.6…10
113 x 35 x 75
XMLA010A2S12
0.5
0.5
1…20
113 x 35 x 75
XMLA020A2S12
0.4
1
1.5…35
113 x 35 x 75
XMLA035A2S12
1.25
1.25
5…70
113 x 35 x 75
XMLA070D2S12
3
7.5
10…160
113 x 35 x 75
XMLA160D2S12
5.5
18
20…300
113 x 35 x 75
XMLA300D2S12
16.5
35
30…500
113 x 35 x 75
XMLA500D2S12
20
45
0.25...4
XMLB004A2S12
0.02
0.25
0.7...10
XMLB010A2S12
0.57
0.85
1.3...20
XMLB020A2S12
1
1.6
3.5...35
XMLB035A2S12
1.7
2.55
7...70
XMLB070D2S12
4.7
8.8
10...160
XMLB160D2S12
9.3
20.8
22...300
XMLB300D2S12
19.4
37
30...500
XMLB500D2S12
23
52.6
2.4
7.5
11 20 50 100 200 300
(1) For electrical connection by DIN 43650A connector (IP 65), replace the suffix “ S12” in the reference by “C11”. Example: XMLB010A2S12 becomes XMLB010A2C11.
(2) For vacuum switch: natural differential to be added to PB to give PH.
(3) For vacuum switch: possible differential to be added to PB to give PH.
(4) Setting range (bar) of lower limit (PB): vacuum switch.
Fluids controlled Hydraulic oils, fresh water, air up to 70°C
Type XMLC - adjustable differential, regulation between 2 thresholds
Setting range (bar) of upper limit (PH): pressure switches
Dimensions (mm) H x W x D
-0.14...-1 (4)
113 x 46 x 85
With setting scale
Possible differential (bar) subtract from PH to give PB
2 C/O single-pole, snap action contacts
Min. at low setting
Min. at high setting
Max. at high setting
XMLCM02V2S12
0.13 (4)
0.14 (4)
0.8 (4)
Hydraulic oils, air up to 160°C
0.05...1
175 x 110 x 110
XMLC001R2S12
0.03
0.04
0.8
Type XMLD - fixed differential, dual stage, for detection at each threshold
Setting range
(bar)
2
1 nd st
stage switching point (PB2)
stage switching point (PB1)
-0.12...-1 (4)
-0.10...-0.98
Spread between 2 stages (PB2 – PB1) -0.02...-0.88
Without setting scale 2 C/O single-pole, snap action contacts (1 per stage) XMLDM02V1S12
Natural differential (bar) subtract from PH 1/2 to give PB 1/2 at low setting at high setting
0.1 (2)
0.1 (2)
0.12...1
0.04...0.92
0.08...0.73
XMLD001R1S12
0.03
0.07
Hydraulic oils, fresh water, air up to 160°C
0.3...2.5
158 x 55 x 90
XMLC002B2S12
0.13
0.17
2
0.34...2.5
0.2...2.36
0.14...1.5
XMLD002B1S12
0.14
0.19
Hydraulic oils, fresh water, air up to 160°C
Hydraulic oils up to 160°C
0.3...4
113 x 46 x 85
XMLC004B2S12
0.15
0.17
2.5
0.7...10
113 x 46 x 85
XMLC010B2S12
0.45
0.7
8
1.3...20
113 x 46 x 85
XMLC020B2S12
0.7
1
11
3.5...35
113 x 46 x 85
XMLC035B2S12
1
1.5
22
7...70
113 x 46 x 85
XMLC070D2S12
4.5
8.9
60
12...160
113 x 46 x 85
XMLC160D2S12
9
21
110
22...300
113 x 46 x 85
XMLC300D2S12
16
35
240
30...500
113 x 46 x 85
XMLC500D2S12
19
52
340
0.40...4
0.19...3.79
0.21...2.18
XMLD004B1S12
0.15
0.19
1.2...10
0.52...9.32
0.68...5.8
XMLD010B1S12
0.45
0.6
2.14...20
0.9...18.76
1.24...9.55
XMLD020B1S12
0.7
1.3
4.4...35
1.9...32.5
2.5...20.4
XMLD035B1S12
1.5
2.6
9.4...70
6.6...67.2
2.8...46
XMLD070D1S12
5
9.5
16.5...160
10.5...154
6...83
XMLD160D1S12
8.8
20
36...300
25...289
11...189
XMLD300D1S12
17
42
41...500
25...484
16...244
XMLD500D1S12
21
65
Other versions: please consult our Customer Care Centre.
17
OsiSense XM Sensors for pressure control
Electromechanical pressure switches XMX, XMA
1 C/O single-pole contact, snap action
Setting range of upper limit (PH) (bar)
Fluids controlled
Ambient air temperature
Degree of protection (conforming to IEC 60529)
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Product certification
Dimensions (mm) H x W x D
Fluid connection
Electrical connection
Type XMX with internal setting screw
Without setting scale, screw terminal connections
1 C/O single-pole, snap action contact
Possible differential (bar) subtract from PH to give PB
Min. at low setting
Min. at high setting
Max. at high setting
1…6 1.3…12 3.5…25
Air, water (fresh water, sea water) from 0…+70°C
- 25…+ 70°C
IP 54
AC-15; B300 (Ue = 240 V, Ie = 1.5 A - Ue = 120 V, Ie = 3 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)
CE - UL - CSA - CCC
106 x 57 x 98
1/4" BSP female
Screw terminals, 2 tapped entries for n° 13 (DIN Pg 13.5) cable gland
126 x 57 x 98
XMXA06L2135
0.8
1.2
4.2
XMXA12L2135
1
1.7
8.4
XMXA25L2135
3.4
4.5
20
1 C/O single-pole contact, snap action
Setting range of upper limit (PH) (bar) 1…6 1.3…12 3.5…25
Fluids controlled
Ambient air temperature
Degree of protection (conforming to IEC 60529)
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Product certification
Dimensions (mm) H x W x D
Fluid connection
Electrical connection
Air, water (fresh water, sea water) from 0…+70°C
- 25…+ 70°C
IP 54
AC-15; B300 (Ue = 240 V, Ie = 1.5 A - Ue = 120 V, Ie = 3 A) / DC-13; R300 (Ue = 250 V, Ie = 0.1 A)
CE - UL - CSA - CCC
113 x 57 x 98
1/4" BSP female
Screw terminals, tapped entry for n° 13 (DIN Pg 13.5) cable gland
133 x 57 x 98
Type XMA with external setting screw (transparent cover)
Without setting scale, screw terminal connections
1 C/O single-pole, snap action contact
Possible differential (bar) subtract from PH to give PB
Min. at low setting
Min. at high setting
Max. at high setting
XMAV06L2135
0.8
1.2
4.2
XMAV12L2135
1
1.7
8.4
XMAV25L2135
3.4
4.5
20
Other versions: please consult our Customer Care Centre.
18
Electromechanical pressure switches for power circuits, adjustable differential for regulation between 2 thresholds
2 NC 2-pole contact, snap action
Degree of protection
Size (bar)
Setting range of upper limit (PH) (bar)
Fluids controlled
Electrical connection
Product certification
Ambient air temperature
Rated operational characteristics (conforming to EN IEC 60947-5-1)
Power rating of controlled motors
110 V
230 / 400 V
AC 2-pole, single-phase
AC 2-pole, 3-phase
AC 2-pole, single-phase
AC 2-pole, 3-phase
Dimensions (mm) H x W x D
Fluid connection G 1/4 (BSP female)
R 1/4 (BSP male)
G 3/8 (BSP female) rotating nut
Possible differential (bar) subtract from PH to give PB
At low setting
At middle setting
At high setting
IP 20
4.6
1.4…4.6
7
2.8…7
10.5
5.6…10.5
Water (fresh water, sea water) from 0…+55°C
Screw terminals, 2 cable entries with grommet
IP 65
4.6
1.4…4.6
7
2.8…7
CE
For operation: 0…+ 50°C. For storage: - 30…+ 80°C
Ie = 10 A, Ue = 250 V AC
Screw terminals, 2 tapped entries for n° 13 (DIN Pg 13.5) cable gland
10.5
5.6…10.5
0.75 kW (1 HP)
1.1 kW (1.5 HP)
1.5 kW (2 HP)
2.2 kW (3 HP)
0.75 kW (1 HP)
1.1 kW (1.5 HP)
1.5 kW (2 HP)
2.2 kW (3 HP)
96/105 x 72 x 102 94 x 72 x 102
FSG2
FSG9
–
FYG22
FYG29
–
FYG32
FYG39
–
115 x 72 x 106
FSG2NE
–
FSG2NEG
115 x 72 x 106
FYG22NE
–
–
FYG32NE
–
–
1 min. - 2.1 max. 1.2 min. - 2.3 max. 1.9 min. - 3 max. 1 min. - 2.1 max. 1.2 min. - 2.3 max. 1.9 min. - 3 max.
1.1 min. - 2.2 max. 1.4 min. - 2.5 max. 2.1 min. - 3.2 max. 1.1 min. - 2.2 max. 1.4 min. - 2.5 max. 2.1 min. - 3.2 max.
1.2 min. - 2.3 max. 1.6 min. - 2.7 max. 2.3 min. - 3.4 max. 1.2 min. - 2.3 max. 1.6 min. - 2.7 max. 2.3 min. - 3.4 max.
2 NC 2-pole contact, snap action
Size (bar)
3 NC 3-pole contact, snap action
Setting range of upper limit (PH) (bar)
Fluids controlled
Ambient air temperature
Decompression valve / ONOff knob
Fluid connection
Electrical connection
Degree of protection
Product certification
Rated insulation voltage
Electrical durability
Power 1.5 kW
2.2 kW
3 kW
Dimensions (mm) H x W x D
Type of contacts 2 NC 2-pole, snap action contact
3 NC 3-pole, snap action contact
Possible differential (bar) subtract from PH to give PB
Min. at low setting
Min. at high setting
Max. at high setting
6 12 25
1…6 1.3.…12
Air, water (fresh water, sea water) from 0…+70°C
For operation: - 25…+ 70°C. For storage: - 40…+ 70°C
3.5…25 without with without with without
G 1/4 (BSP female) 4 x G 1/4 (BSP female) G 1/4 (BSP female) 4 x G 1/4 (BSP female) G 1/4 (BSP female)
Screw terminals, 2 tapped entries for n° 13 (DIN Pg 13.5) cable gland
IP 54 IP 54
CE - CCC
Ui = 500 V
400 V AC 3-phase: 1 000 000 operating cycles
230 V AC 3-phase: 600 000 operating cycles
IP 54
400 V AC 3-phase: 700 000 operating cycles
400 V AC 3-phase: 500 000 operating cycles
106 x 57 x 97.5
XMPA06B2131
XMPA06C2131
0.8
1.2
4.2
138 x 57 x 97.5
–
XMPE06C2431
0.8
1.2
4.2
1.7
8.4
106 x 57 x 97.5
XMPA12B2131
XMPA12C2131
1
138 x 57 x 97.5
XMPE12B2431
XMPE12C2431
1
1.7
8.4
126 x 57 x 97.5
XMPA25B2131
XMPA25C2131
3.4
4.5
20
Other versions: please consult our Customer Care Centre.
19
OsiSense XS
Inductive proximity sensors
Cylindrical metal
Non flush mountable
Flush mountable
Nominal sensing distance Sn
Flush standard and increased range
M8
1.5 mm
Usable sensing distance S (mm) flush mountable / non flush mountable 0…1.2
2.5 mm
0…2
Temperature range (°C) - 25…+ 70
Product certification CE - UL - CSA - CCC (in progress) - C-TICK
Degree of protection (conforming to IEC 60529) IP 67
Sensors for DC applications
Output function NO
NC
Dimensions (mm) Ø x L Cable / Connector
3-wire PNP
NPN
Cable (2 m)
Connector M8 / M12
Cable (2m)
Connector M8 / M12
2-wire non
polarised (1)
Cable (2 m)
Connecteur M12
Supply voltage limits, min./max. (V) including ripple
A
B
M8 x 33 / M8 x 42
XS508B1PAL2
XS508B1PAM8
XS508B1N AL2
XS508B1N AM8
XS508BSC AL2
XS508BSC AL01M12
10…36
Switching capacity, max. (mA) 3-wire / 2-wire 200 / 100
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
Residual current, open state (mA)
Voltage drop, closed state (V) at I nominal 3-wire / 2-wire
Switching frequency (Hz) 3-wire / 2-wire
≤ 0.5
≤ 2 / ≤ 4
5000 / 4000
A
B
XS108B3PAL2
XS108B3PAM8
XS108B3N AL2
XS108B3N AM8
XS608B3C AL2
XS608B3C AL01M12
10…36
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
2500 / 3000
Dimensions (mm) Ø x L Cable / connector
3-wire PNP
NPN
Cable (2 m)
Connector M12
Cable (2 m)
Connector M12
2-wire non Cable (2 m) polarised Connector M12
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA) 3-wire / 2-wire
Overload and short-circuit protection (g) / LED output state indicator (⊗)
Residual current, open state (mA) 2-wire
Voltage drop, closed state (V) at I nominal 3-wire / 2-wire
Switching frequency (Hz) 3-wire / 2-wire
M8 x 51 / M8 x 62
XS508BLPAL2
XS508BLPAM12
XS508BLN AL2
XS508BLN AM12
XS508B1D AL2
XS508B1D AM12
10…58
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
5000 / 4000
Multi-current/multi-voltage sensors for AC/DC applications
Dimensions (mm) Ø x L Cable / connector –
2-wire Cable (2 m) –
Connector 1/2"-20 UNF –
Supply voltage limits, min./max. (V) including ripple –
Switching capacity, max. (mA)
LED output state indicator (⊗)
Residual current, open state (mA)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
(1) polarised for M8 short
–
–
–
–
–
Accessories
Fixing for cylindrical sensors
Fixing clamp with indexing pin for cylindrical sensors
M8
M12
M18
M30
XSZB108
XSZB112
XSZB118
XSZB130
–
–
–
–
–
–
–
–
–
XS608B1PAL2
XS608B1PAM12
XS608B1N AL2
XS608B1N AM12
XS608B1D AL2
XS608B1D AM12
10…58
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
2500 / 3000
M12
2 mm
0…1.6
pre-cabled: IP 69K conforming to DIN 40050, IP 68
A
B
M12 x 35 / M12 x 50
XS512B1PAL2
XS512B1PAM12
XS512B1N AL2
XS512B1N AM12
XS512BSD AL2
XS512BSD AM12
10…36
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
5000 / 4000
M12 x 53 / M12 x 62
XS512BLPAL2
XS512BLPAM12
XS512BLN AL2
XS512BLN AM12
XS512B1D AL2
XS512B1D AM12
10…58
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
5000 / 4000
M12 x 53 / M12 x 62
XS512B1M AL2
XS512B1M AU20
20…264
200
⊗
≤ 0,8
≤ 5.5
25 AC / 1000 DC
Suitable female plug-in connectors
M8
Metal ring
Straight
XZCC8FDM30S
M12 (4 pin)
Metal ring
Plastic ring
XZCC12FDM40B
XZCC12FDP40B
4 mm
0…3.2
XS112B3PAL2
XS112B3PAM12
XS112B3N AL2
XS112B3N AM12
XS612B3D AL2
XS612B3D AM12
10…36
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
2500 / 2000
XS612B1PAL2
XS612B1PAM12
XS612B1N AL2
XS612B1N AM12
XS612B1D AL2
XS612B1D AM12
10…58
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
2500 / 2000
XS612B1M AL2
XS612B1M AU20
20…264
200
⊗
≤ 0,8
≤ 5.5
25 AC / 1000 DC
Elbowed
XZCC8FCM30S
A
B
XZCC12FCM40B
XZCC12FCP40B
Other versions: please consult our Customer Care Centre.
20
Accessories
Fixing for cylindrical sensors
Fixing clamp with indexing pin for cylindrical sensors
M8
M12
M18
M30
XSZB108
XSZB112
XSZB118
XSZB130
Suitable female plug-in connectors
M8
Metal ring
Straight
XZCC8FDM30S
M12 (4 pin)
Metal ring
Plastic ring
XZCC12FDM40B
XZCC12FDP40B
Elbowed
XZCC8FCM30S
XZCC12FCM40B
XZCC12FCP40B
M18
5 mm
0…4
- 25…+ 70
8 mm
0…6.4
CE - UL - CSA - CCC (in progress) - C-TICK
(with connector: IP 67)
A
B
M18 x 39 / M18 x 50
XS518B1PAL2
XS518B1PAM12
XS518B1N AL2
XS518B1N AM12
XS518BSD AL2
XS518BSD AM12
10…36
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
2000 / 3000
M18 x 62 / M18 x 74
XS518BLPAL2
XS518BLPAM12
XS518BLN AL2
XS518BLN AM12
XS518B1D AL2
XS518B1D AM12
10…58
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
2000 / 3000
B
XS118B3PAL2
XS118B3PAM12
XS118B3N AL2
XS118B3N AM12
XS618B3D AL2
XS618B3D AM12
10…36
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
1000 / 1000
A
XS618B1PAL2
XS618B1PAM12
XS618B1N AL2
XS618B1N AM12
XS618B1D AL2
XS618B1D AM12
10…58
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
1000 / 1000
M18 x 62 / M18 x 73
XS518B1M AL2
XS518B1M AU20
20…264
300 AC / 200 DC
⊗
≤ 0.8
≤ 5.5
25 AC / 1000 DC
XS618B1M AL2
XS618B1M AU20
20…264
300 AC / 200 DC
⊗
≤ 0.8
≤ 5.5
25 AC / 1000 DC
M30
10 mm
0…8
15 mm
0…12
A
B
M30 x 43 / M30 x 55
XS530B1PAL2
XS530B1PAM12
XS530B1N AL2
XS530B1N AM12
XS530BSD AL2
XS530BSD AM12
10…36
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
1000 / 2000
M30 x 62
XS530BLPAL2
XS530BLPAM12
XS530BLN AL2
XS530BLN AM12
XS530B1D AL2
XS530B1D AM12
10…58
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
1000 / 2000
B
XS130B3PAL2
XS130B3PAM12
XS130B3N AL2
XS130B3N AM12
XS630B3D AL2
XS630B3D AM12
10…36
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
500 / 500
A
XS630B1PAL2
XS630B1PAM12
XS630B1N AL2
XS630B1N AM12
XS630B1D AL2
XS630B1D AM12
10…58
200 / 100 g / ⊗
≤ 0.5
≤ 2 / ≤ 4
500 / 500
M30 x 62 / M30 x 73
XS530B1M AL2
XS530B1M AU20
20…264
300 AC / 200 DC
⊗
≤ 0.8
≤ 5.5
25 AC / 500 DC
XS630B1M AL2
XS630B1M AU20
20…264
300 AC / 200 DC
⊗
≤ 0.8
≤ 5.5
25 AC / 500 DC
Non flush increased range
M12 M18
7 mm
0…5.6
12 mm
0…9.6
M30
22 mm
0…17.6
- 25…+ 70
CE - UL - CSA - CCC (in progress) - C-TICK pre-cabled: IP 69K conforming to DIN 40050, IP 68 (with connector: IP 67)
–
–
–
–
–
–
–
–
–
A
B
–
–
–
–
–
–
–
–
–
–
–
–
–
M12 x 55 / M12 x 65
XS612B4PAL2
XS612B4PAM12
XS612B4N AL2
XS612B4N AM12
–
–
10…58
200 / – g / ⊗
–
≤ 2 / –
2500 / –
A
B
A
B
M18 x 62 / M18 x 74
XS618B4PAL2
XS618B4PAM12
XS618B4N AL2
XS618B4N AM12
–
–
10…58
200 / – g / ⊗
–
≤ 2 / –
1000 / –
M30 x 62 / M30 x 74
XS630B4PAL2
XS630B4PAM12
XS630B4N AL2
XS630B4N AM12
–
–
10…58
200 / – g / ⊗
–
≤ 2 / –
500 / –
M18 x 60 / M18 x 72
XS618B4M AL2
XS618B4M AU20
20…264
300 AC / 200 DC
⊗
≤ 0.8
≤ 5.5
25 AC / 1000 DC
M30 x 63 / M30 x 74
XS630B4M AL2
XS630B4M AU20
20…264
300 AC / 200 DC
⊗
≤ 0.8
≤ 5.5
25 AC / 300 DC
PUR pre-wired connectors (1)
Straight Elbowed
(1) For PVC cable see page 47
M8 (3 pin)
Straight Elbowed
1/2"
Straight Elbowed
M12 (4 pin)
Straight Elbowed Elbowed PNP LED
2 m XZCP0566L2 XZCP0666L2
5 m XZCP0566L5 XZCP0666L5
2 m
5 m
XZCP1865L2 XZCP1965L2
XZCP1865L5 XZCP1965L5
2 m
5 m
XZCP1141L2 XZCP1241L2 XZCP1340L2
XZCP1141L5 XZCP1241L5 XZCP1340L5
10 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10
Other versions: please consult our Customer Care Centre.
21
OsiSense XS Inductive proximity sensors
Rectangular plastic
Non flush mountable
Flush mountable
U 8 x 22 x 8 U 15 x 32 x 8 U 26 x 26 x 13 U 40 x 40 x 15 U 80 x 80 x 26
Nominal sensing distance Sn 2.5 mm
Usable sensing distance S (mm) flush mountable / non flush mountable 0...2
Fine adjustment zone (mm) flush mountable / non flush mountable
Suitability for flush mounting (metal environment)
Temperature range (°C)
Product certification
Degree of protection (conforming to IEC 60529)
5 mm
0...4
10
0…8 mm
– flush mountable
- 25…+ 70
CE
– flush mountable
- 25…+ 70
– flush mountable
- 25…+ 70
CE - UL - CSA - C-TICK pre-cabled: IP 68 (with connector: IP 67)
15 mm
0…12
– flush mountable
- 25…+ 70
40 mm
0…32
– flush mountable
- 25…+ 70
Sensors for DC applications
Connection
2-wire (non polarised)
2-wire
NO or NC
NO function programmable
NC function
4-wire
3-wire
PNP
NPN
PNP
NPN
NO + NC
NO + NC
NO function
NC function
NO function
NC function complementary outputs complementary outputs
Connection
2-wire NO function
NC function
3-wire PNP
NPN
NO function
NC function
NO function
NC function
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA)
Short-circuit protect. (g) / LED output state indicator (⊗) / Power on LED (⊗)
Voltage drop, closed state (V) at I nominal cable / Connector
Switching frequency (Hz) cable / Connector
Pre-cabled, PvR (2 m)
– –
XS7J1A1DAL2
XS7J1A1DBL2
–
– –
XS7F1A1DAL2
XS7F1A1DBL2
–
–
XS7E1A1DAL2
XS7E1A1DBL2
–
–
XS7J1A1PAL2
XS7J1A1PBL2
XS7J1A1NAL2
XS7J1A1NBL2
XS7F1A1PAL2
XS7F1A1PBL2
XS7F1A1NAL2
XS7F1A1NBL2
XS7E1A1PAL2
XS7E1A1PBL2
XS7E1A1NAL2
XS7E1A1NBL2
M8 connector
XS7J1A1DAL01M8 (1) XS7F1A1DAL01M8 (1) XS7E1A1DAM8
XS7J1A1DBL01M8 (1) XS7F1A1DBL01M8 (1) XS7E1A1DBM8
XS7J1A1PAL01M8 (1) XS7F1A1PAL01M8 (1) XS7E1A1PAM8
XS7J1A1PBL01M8 (1) XS7F1A1PBL01M8 (1) XS7E1A1PBM8
XS7J1A1NAL01M8 (1) XS7F1A1NAL01M8 (1) XS7E1A1NAM8
XS7J1A1NBL01M8 (1) XS7F1A1NBL01M8 (1) XS7E1A1NBM8
10…36 10…36 10…36
100 g / ⊗ / –
100 g / ⊗ / –
100 g / ⊗ / –
≤ 4 / ≤ 2
4000 / 2000
≤ 4 / ≤ 2
5000 / 2000
≤ 2
1000
Multi-current/multi-voltage sensors for AC/DC applications
Connection
– 2-wire AC/DC
AC
AC/DC
NO function
NC function
NO or NC programmable
NO or NC programmable
Connection
2-wire AC/DC NO function
NC function
Supply voltage limits, min./max. (V) including ripple
–
–
–
–
–
–
Switching capacity, max. (mA)
Short-circuit protect. (g) / LED output state indicator (⊗) / Power on LED (⊗)
Residual current, open state (mA)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Accessories
Fixing for flat sensors flat
90°
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
(1) M8 connector on flying lead (L = 0.15 m).
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Suitable female plug-in connectors
8x22x8 flat 90° M8
XSZBJ00 XSZBJ90 Metal ring
15x32x8 XSZBF00 XSZBF90 M12 (4 pin)
26x26x13 XSZBE00 XSZBE90 Metal ring
40x40x15 XSZBC00 XSZBC90 Plastic ring
Straight
XZCC8FDM30S
XZCC12FDM40B
XZCC12FDP40B
–
XS7C1A1DAL2
XS7C1A1DBL2
–
–
XS7C1A1PAL2
XS7C1A1PBL2
XS7C1A1NAL2
XS7C1A1NBL2
XS7C1A1DAM8
XS7C1A1DBM8
XS7C1A1PAM8
XS7C1A1PBM8
XS7C1A1NAM8
XS7C1A1NBM8
10…36
100 g / ⊗ / –
≤ 2
1000
–
–
–
–
–
–
–
–
–
–
–
–
–
XS7D1A1DAL2
XS7D1A1DBL2
–
–
XS7D1A1PAL2
XS7D1A1PBL2
XS7D1A1NAL2
XS7D1A1NBL2
M12 connector
XS7D1A1DAM12
XS7D1A1DBM12
XS7D1A1PAM12
XS7D1A1PBM12
XS7D1A1NAM12
XS7D1A1NBM12
10…36
100 g / ⊗ / –
≤ 2
100
Elbowed
XZCC8FCM30S
XZCC12FCM40B
XZCC12FCP40B
Other versions: please consult our Customer Care Centre.
22
Inductive proximity sensors
Rectangular plastic
Accessories
Fixing for flat sensors Suitable female plug-in connectors
8x22x8 flat 90° M8
XSZBJ00 XSZBJ90 Metal ring
15x32x8 XSZBF00 XSZBF90 M12 (4 pin)
26x26x13 XSZBE00 XSZBE90 Metal ring
40x40x15 XSZBC00 XSZBC90 Plastic ring
Straight
XZCC8FDM30S
XZCC12FDM40B
XZCC12FDP40B
Elbowed
XZCC8FCM30S
XZCC12FCM40B
XZCC12FCP40B
U 40 x 40 x 70
20 mm
0…16
40 mm
0…32 flush mountable
- 25…+ 70 non flush mountable
CE - UL - CSA - CCC - C-TICK
IP67 and IP69K
U 40 x 40 x 117
20 mm
0…16 flush mountable
40 mm
0…32 non flush mountable
U 26 x 26 x 13 U 40 x 40 x 15 U 80 x 80 x 26
15 mm
0…8 / 0...12
25 mm
0…12 / 0...20
60 mm
0…32 / 0...48
5...10 / 5...15
8...15 / 8...25
20...40 / 20...60
flush mountable or non flush mountable via teach mode
- 25…+ 70
CE - UL - CSA - CCC - C-TICK pre-cabled: IP 68 (with connector: IP 67)
–
–
–
M12 connector
–
XS8C2A1DAM12
XS8C2A1DBM12
XS8C2A1PCM12
XS8C2A1NCM12
–
–
–
–
–
XS8C2A4DAM12
XS8C2A4DBM12
XS8C2A4PCM12
XS8C2A4NCM12
–
–
–
–
–
–
–
–
–
–
–
–
–
12…48
4-wire version = 200 – 2-wire version = 1.5…100
4-wire version = g / ⊗ / ⊗ – 2-wire version = g / ⊗ / –
4-wire version = ≤ 2 – 2-wire version = ≤ 4 flush version : 300 - Non flush version : 200
–
–
–
–
–
–
Screw terminals (2)
XS8C4A1DPP20
–
–
–
–
XS8C4A1PCP20
XS8C4A1NCP20
–
–
–
–
–
–
–
–
XS8C4A4DPP20
–
–
–
–
XS8C4A4PCP20
XS8C4A4NCP20
–
–
–
–
Pre-cabled (2 m)
–
–
–
XS8E1A1PAL2
XS8E1A1PBL2
XS8E1A1NAL2
XS8E1A1NBL2
M8 connector
–
–
XS8E1A1PAM8
XS8E1A1PBM8
XS8E1A1NAM8
XS8E1A1NBM8
10…36
100 g / ⊗ / ⊗
≤ 2
2000
–
–
–
–
–
XS8C1A1PAL2
XS8C1A1PBL2
XS8C1A1NAL2
XS8C1A1NBL2
–
–
XS8C1A1PAM8
XS8C1A1PBM8
XS8C1A1NAM8
XS8C1A1NBM8
10…36
200 g / ⊗ / ⊗
≤ 2
1000 v
–
–
–
–
XS8D1A1PAL2
XS8D1A1PBL2
XS8D1A1NAL2
XS8D1A1NBL2
M12 connector
–
–
XS8D1A1PAM12
XS8D1A1PBM12
XS8D1A1NAM12
XS8D1A1NBM12
10…36
200 g / ⊗ / ⊗
≤ 2
150
1/2"- 20 UNF connector
XS8C2A1MAU20
XS8C2A1MBU20
–
–
XS8C2A4MAU20
XS8C2A4MBU20
–
–
–
–
Screw terminals (2)
–
XS8C4A1MPP20
–
–
–
XS8C4A4MPP20
Pre-cabled (2 m)
XS8E1A1MAL2
XS8E1A1MBL2
–
–
XS8C1A1MAL2
XS8C1A1MBL2
–
–
–
–
20…264
–
–
AC/DC version = 300 / 200
– / ⊗ / –
AC/DC version = ≤ 1.5
≤ 5.5
25 AC / 50 DC
–
–
–
–
1/2"-20 UNF connector
XS8E1A1MAL01U20
XS8E1A1MBL01U20
20…264
200 AC or DC
– / ⊗ / ⊗
≤ 1.5
≤ 5.5
2000
XS8C1A1MAL01U20
XS8C1A1MBL01U20
20…264
300 AC / 200 DC
– / ⊗ / ⊗
≤ 1.5
≤ 5.5
1000
(2) Sensors supplied without cable gland. Suitable cable gland: M20. Also available in13P, 1/2" NPT output and M12, 7/8" connectors.
XS8D1A1MAL2
XS8D1A1MBL2
–
–
XS8D1A1MAU20
XS8D1A1MBU20
20…264
300 AC / 200 DC
– / ⊗ / ⊗
≤ 1.5
≤ 5.5
150
PUR pre-wired connectors (1)
Straight Elbowed
(1) For PVC cable see page 47
M8 (3 pin)
Straight Elbowed
1/2"
Straight Elbowed
M12 (4 pin)
Straight Elbowed Elbowed PNP LED
2 m XZCP0566L2 XZCP0666L2
5 m XZCP0566L5 XZCP0666L5
2 m
5 m
XZCP1865L2 XZCP1965L2
XZCP1865L5 XZCP1965L5
2 m
5 m
XZCP1141L2 XZCP1241L2 XZCP1340L2
XZCP1141L5 XZCP1241L5 XZCP1340L5
10 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10
Other versions: please consult our Customer Care Centre.
23
OsiSense XS Inductive proximity sensors
Cylindrical Plastic
Non flush mountable
Flush mountable
M8 M12 M18
Nominal sensing distance Sn
Operating zone (mm)
Suitability for flush mounting (metal environment)
Temperature range (°C)
Product certification
Degree of protection (conforming to IEC 60529)
2.5 mm
0…2
4 mm
0…3.2
8 mm
0…6.4
non flush mountable
- 25…+ 70
CE - UL - CSA - CCC - C-TICK
IP 67 pre-cabled: IP 68 (with connector: IP 67)
Sensors for DC applications
Connection
Dimensions (mm) Ø x L
3-wire PNP
NPN
NO function
NC function
NO function
NC function
Connection
Dimensions (mm) Ø x L
3-wire PNP
NPN
NO function
NC function
NO function
NC function
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA)
Short-circuit protect. (g) / LED output state indicator (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Pre-cabled, PvR (2 m)
M8 x 33
XS4P08PA340
XS4P08PB340
XS4P08NA340
XS4P08NB340
M8 connector
M8 x 42
XS4P08PA340S
XS4P08PB340S
XS4P08NA340S
XS4P08NB340S
10…38
200 g / ⊗
≤ 2
5000
M12 x 33
XS4P12PA340
XS4P12PB340
XS4P12NA340
XS4P12NB340
M12 connector
M12 x 48
XS4P12PA340D
XS4P12PB340D
XS4P12NA340D
XS4P12NB340D
10…38
200 g / ⊗
≤ 2
5000
Multi-current/multi-voltage sensors for AC/DC applications
Connection Pre-cabled, PvR (2 m)
Dimensions (mm) Ø x L M8 x 50
2-wire not short-circuit protected (1)
Connection
Dimensions (mm) Ø x L
AC/DC NO function
NC function
2-wire not short-circuit protected (1)
AC/DC NO function
NC function
Supply voltage limits, min./max. (V) including ripple
XS4P08MA230
XS4P08MB230
1/2" connector
M8 x 61
XS4P08MA230K
XS4P08MB230K
20…264
M12 x 50
XS4P12MA230
XS4P12MB230
M12 x 61
XS4P12MA230K
XS4P12MB230K
20…264
Switching capacity, max. (mA)
LED output state indicator (⊗)
Residual current, open state (mA)
Voltage drop, closed state (V) at I nominal
100
⊗
≤ 0.6
≤ 5.5
200
⊗
≤ 0.6
≤ 5.5
Switching frequency (Hz) 25 AC / 3000 DC 25 AC / 3000 DC
(1) For these sensors without short-circuit protection, it is essential to connect a 0.4 A quick-blow fuse in series with the load.
M18 x 33.5
XS4P18PA340
XS4P18PB340
XS4P18NA340
XS4P18NB340
M18 x 48
XS4P18PA340D
XS4P18PB340D
XS4P18NA340D
XS4P18NB340D
10…38
200 g / ⊗
≤ 2
2000
M18 x 60
XS4P18MA230
XS4P18MB230
M18 x 70
XS4P18MA230K
XS4P18MB230K
20…264
300 AC / 200 DC
⊗
≤ 0.6
≤ 5.5
25 AC / 2000 DC
M30
15 mm
0…12
M30 x 40.5
XS4P30PA340
XS4P30PB340
XS4P30NA340
XS4P30NB340
M30 x 50
XS4P30PA340D
XS4P30PB340D
XS4P30NA340D
–
10…38
200 g / ⊗
≤ 2
1000
M30 x 60
XS4P30MA230
XS4P30MB230
M30 x 70
XS4P30MA230K
XS4P30MB230K
20…264
300 AC / 200 DC
⊗
≤ 0.6
≤ 5.5
25 AC / 1000 DC
Accessories
Fixing for cylindrical sensors
Fixing clamp with indexing pin for cylindrical sensors
M4
M5
M6.5
M8
XSZB104 M12
XSZB105 M18
XSZB165 M30
XSZB108
XSZB112
XSZB118
XSZB130
Suitable female plug-in connectors
M8
Metal ring
Straight
XZCC8FDM30S
M12 (4 pin)
Metal ring
Plastic ring
XZCC12FDM40B
XZCC12FDP40B
Elbowed
XZCC8FCM30S
XZCC12FCM40B
XZCC12FCP40B
Other versions: please consult our Customer Care Centre.
24
Miniature cylindrical metal (assembly)
Nominal sensing distance Sn
Operating zone (mm)
Suitability for flush mounting (metal environment)
Temperature range (°C)
Product certification
Degree of protection (conforming to IEC 60529)
Sensors for DC applications
Dimensions (mm) Ø x L
Connection
3-wire PNP
NPN
2-wire (polarised)
NO function
NC function
NO function
NC function
NO function
NC function
Dimensions (mm) Ø x L
Connection
3-wire PNP
NPN
NO function
NC function
NO function
NC function
Connection
2-wire (polarised) fonction NO
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA) 3-wire / 2-wire
Short-circuit protect. (g) / LED output state indicator (⊗)
Voltage drop, closed state (V) at I nominal 3-wire / 2-wire
Switching frequency (Hz) 3-wire / 2-wire
(1) Stainless steel sensors, Sn = 0.8 mm
Ø 4 M5
1 mm
0…0.8
1 mm
0…0.8
flush mountable
- 25…+ 70
CE - UL - CSA - CCC - C-TICK
IP 67
Ø 6.5
1.5 mm
0…1.2
2.5
0…2 mm
Ø 4 x 29
–
–
–
Pre-cabled, PvR (2 m)
XS1L04PA310
–
XS1L04NA310
Ø 4 x 41
M8
XS1L04PA310S
–
XS1L04NA310S
–
M12
–
5…30
100 / – g / ⊗
≤ 2 / –
5000 / –
M5 x 29
–
–
XS1N05PA310
–
XS1N05NA310
–
M5 x 41
XS1N05PA311S (1)
–
XS1N05NA311S (1)
–
–
5…30
100 / – g / ⊗
≤ 2 / –
5000 / –
Ø 6.5 x 33
XS506B1PAL2
XS506B1PBL2
XS506B1NAL2
XS506B1NBL2
XS506BSCAL2
XS506BSCBL2
Ø 6.5 x 42
XS506B1PAM8
XS506B1PBM8
XS506B1NAM8
XS506B1NBM8
XS506BSCAL01M12
10…36
200 / 100 g / ⊗
≤ 2 / ≤ 4
5000 / 4000
XS106B3PAL2
XS106B3PBL2
XS106B3NAL2
XS106B3NBL2
XS606B3CAL2
XS606B3CBL2
XS106B3PAM8
XS106B3PBM8
XS106B3NAM8
XS106B3NBM8
XS506B3CAL01M12
2500 / 3000
Accessories
Fixing for cylindrical sensors
Fixing clamp with indexing pin for cylindrical sensors
M4
M5
M6.5
M8
XSZB104 M12
XSZB105 M18
XSZB165 M30
XSZB108
XSZB112
XSZB118
XSZB130
Suitable female plug-in connectors
M8
Metal ring
Straight
XZCC8FDM30S
M12 (4 pin)
Metal ring
Plastic ring
XZCC12FDM40B
XZCC12FDP40B
Elbowed
XZCC8FCM30S
XZCC12FCM40B
XZCC12FCP40B
PUR pre-wired connectors (1)
Straight Elbowed
(1) For PVC cable see page 47
M8 (3 pin)
Straight Elbowed
1/2"
Straight Elbowed
M12 (4 pin)
Straight Elbowed Elbowed PNP LED
2 m XZCP0566L2 XZCP0666L2
5 m XZCP0566L5 XZCP0666L5
2 m
5 m
XZCP1865L2 XZCP1965L2
XZCP1865L5 XZCP1965L5
2 m
5 m
XZCP1141L2 XZCP1241L2 XZCP1340L2
XZCP1141L5 XZCP1241L5 XZCP1340L5
10 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10
Other versions: please consult our Customer Care Centre.
25
OsiSense XS Inductive proximity sensors
Multi-voltage with short-circuit protection
Non flush mountable
Flush mountable
M12 M18
Sensing distance Sn
Operating zone (mm) flush mountable non flush mountable flush mountable non flush mountable
Suitability for flush mounting (metal environment)
Case M (metal) P (plastic)
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Product certification
Dimensions (mm) Ø x L Cable (Connector)
Sensors for DC applications
Connection
4-wire PNP
NPN
NO + NC
NO + NC
PNP+NPN NO/NC programmable flush mountable non flush mountable flush mountable non flush mountable flush mountable (metal) non flush mntbl. (metal) non flush mntbl. (plastic)
Connection
4-wire PNP
NPN
NO + NC
NO + NC flush mountable non flush mountable flush mountable non flush mountable
PNP+NPN NO/NC programmable flush mountable (metal) non flush mntbl. (metal) non flush mntbl. (plastic)
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA)
Short-circuit protection (g) / LED output state indicator (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2 mm
4 mm
0…1.6
5 mm
8 mm
0…4
0…3.2
0…6.4
flush mountable or non flush mountable depending on model
M
- 25…+ 70
IP 68 (with connector: IP 67)
CE - UL - CSA - CCC - C-TICK
M12 x 55 (M12 x 66) M18 x 60 (M18 x 72)
Multi-current/multi-voltage sensors for AC/DC applications
Connection Pre-cabled, PvR (2 m)
2-wire AC/DC
Connection
NO function
NC function flush mountable non flush mountable flush mountable non flush mountable
XS1M12MA250
XS2M12MA250
XS1M12MB250
XS2M12MB250
1/2"-20 UNF connector
2-wire AC/DC NO function
NC function flush mountable non flush mountable flush mountable non flush mountable
Supply voltage limits, min./max. (V) 50-60 Hz
Switching capacity, max. (mA)
LED output state indicator (⊗) / Power on LED (⊗)
Residual current, open state (mA)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
(1) 25 AC, 1000 DC for non flush mountable Ø 30 mm.
XS1M12MA250K
XS2M12MA250K
XS1M12MB250K
–
20…264
5…200
⊗ / ⊗
≤ 1.5
≤ 5.5
25 AC, 4000 DC
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XS1M18MA250
XS2M18MA250
XS1M18MB250
XS2M18MB250
XS1M18MA250K
XS2M18MA250K
XS1M18MB250K
XS2M18MB250K
5…200 AC, 5…300 DC
25 AC, 2000 DC
M30
10 mm
15 mm
0…8
0…12
25 AC, 2000 DC (1)
M30 x 60 (M30 x 72)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XS1M30MA250
XS2M30MA250
XS1M30MB250
XS2M30MB250
XS1M30MA250K
XS2M30MA250K
XS1M30MB250K
XS2M30MB250K
Other versions: please consult our Customer Care Centre.
26
PNP or NPN
NO + NC Complementary outputs
PNP + NPN outputs,
NO or NC programmable
M12 M18
Sensing distance Sn
Operating zone (mm) flush mountable non flush mountable flush mountable non flush mountable
Suitability for flush mounting (metal environment)
Case M (metal) P (plastic)
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Product certification
Dimensions (mm) Ø x L Cable (Connector)
Sensors for DC applications
Connection
4-wire PNP
NPN
NO + NC
NO + NC
PNP+NPN NO/NC programmable flush mountable non flush mountable flush mountable non flush mountable flush mountable (metal) non flush mntbl. (metal) non flush mntbl. (plastic)
Connection
4-wire PNP
NPN
NO + NC
NO + NC flush mountable non flush mountable flush mountable non flush mountable
PNP+NPN NO/NC programmable flush mountable (metal) non flush mntbl. (metal) non flush mntbl. (plastic)
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA)
Short-circuit protection (g) / LED output state indicator (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
2 mm
4 mm
0…1.6
5 mm
8 mm
0…4
0…3.2
0…6.4
flush mountable or non flush mountable depending on model
M
- 25…+ 70
IP 68 (with connector: IP 67)
CE - UL - CSA - CCC - C-TICK
M12 x 55 (M12 x 66) M18 x 60 (M18 x 72)
Multi-current/multi-voltage sensors for AC/DC applications
Connection Pre-cabled, PvR (2 m)
2-wire AC/DC
Connection
NO function
NC function flush mountable non flush mountable flush mountable non flush mountable
XS1M12MA250
XS2M12MA250
XS1M12MB250
XS2M12MB250
1/2"-20 UNF connector
2-wire AC/DC NO function
NC function flush mountable non flush mountable flush mountable non flush mountable
Supply voltage limits, min./max. (V) 50-60 Hz
Switching capacity, max. (mA)
LED output state indicator (⊗) / Power on LED (⊗)
Residual current, open state (mA)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
(1) 25 AC, 1000 DC for non flush mountable Ø 30 mm.
XS1M12MA250K
XS2M12MA250K
XS1M12MB250K
–
20…264
5…200
⊗ / ⊗
≤ 1.5
≤ 5.5
25 AC, 4000 DC
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XS1M18MA250
XS2M18MA250
XS1M18MB250
XS2M18MB250
XS1M18MA250K
XS2M18MA250K
XS1M18MB250K
XS2M18MB250K
5…200 AC, 5…300 DC
25 AC, 2000 DC
M30
10 mm
15 mm
0…8
0…12
25 AC, 2000 DC (1)
M30 x 60 (M30 x 72)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XS1M30MA250
XS2M30MA250
XS1M30MB250
XS2M30MB250
XS1M30MA250K
XS2M30MA250K
XS1M30MB250K
XS2M30MB250K
M8 M12 M18 M30 M12 M18 M30
1.5
mm
2.5
mm
0…1.2
2 mm
4 mm
0…1.6
5 mm
8 mm
0…4
10 mm
15 mm
0…8
2 mm
4 mm
0…1.6
5 mm
8 mm
0…4
10 mm
15 mm
0…8
0…2 0…3.2
0…6.4
flush mountable or non flush mountable depending on model
M
- 25…+ 70
0…12 0…3.2
0…6.4
0…12 flush mountable or non flush mountable depending on model
M or P depending on model
- 25…+ 70
IP 67 IP 68 (with connector: IP 67)
CE - UL - CSA - CCC - C-TICK
M8 x 50 (M8 x 61) M12 x 33 (M12 x 48)
IP 68 (with connector: IP 67)
CE - UL - CSA - CCC - C-TICK
M18 x 36.5 (M18 x 49) M30 x 40.5 (M30 x 53) M12 x 50 (M12 x 61) M18 x 60 (M18 x 72) M30 x 60 (M30 x 72)
Pre-cabled, PvR (2 m)
XS1M08PC410
XS2M08PC410
XS1M08NC410
–
–
XS2M08NC410
–
M12 connector
XS1M08PC410D
XS2M08PC410D
XS1M08NC410D
–
–
XS2M08NC410D
–
10…36
200 g / ⊗
≤ 2
5000
–
–
–
XS1N12PC410
XS2N12PC410
XS1N12NC410
XS2N12NC410
–
–
–
XS1N12PC410D
XS2N12PC410D
XS1N12NC410D
XS2N12NC410D
5000
–
–
–
XS1N18PC410
XS2N18PC410
XS1N18NC410
XS2N18NC410
–
–
–
XS1N18PC410D
XS2N18PC410D
XS1N18NC410D
XS2N18NC410D
2000
–
–
–
XS1N30PC410
XS2N30PC410
XS1N30NC410
XS2N30NC410
–
–
–
XS1N30PC410D
XS2N30PC410D
XS1N30NC410D
XS2N30NC410D
1000
–
–
Pre-cabled, PvR (2 m)
–
–
XS1M12KP340
XS2M12KP340
XS4P12KP340
–
–
M12 connector
–
–
XS1M12KP340D
XS2M12KP340D
XS4P12KP340D
10…36
200 g / –
≤ 2.6
5000
–
–
–
XS1M18KP340
XS2M18KP340
XS4P18KP340
–
–
–
–
XS1M18KP340D
XS2M18KP340D
XS4P18KP340D
2000
–
–
–
XS1M30KP340
XS2M30KP340
XS4P30KP340
–
–
–
–
XS1M30KP340D
XS2M30KP340D
XS4P30KP340D
1000
PNP
PNP
NO
NC
+
–
NPN
NPN
NO
NC
+
–
NO
NPN
PNP
+ BN/1
- BU/3
NC
NPN
PNP
+ BU/3
- BN/1
Accessories
Fixing clamps
With indexing pin for cylindrical sensors
Suitable female plug-in connectors, including PUR pre-wired versions (1) length 5 m without LED pre-wired, elbowed pre-wired, straight screw terminal
M8
M12
M18
M30
XSZB108
XSZB112
XSZB118
XSZB130
M8 (or S)
M12 (or D)
1/2" (or K)
XZCP0666L5
XZCP1241L5
XZCP1965L5
(1) For PVC cable see page 47
XZCP0566L5
XZCP1141L5
XZCP1865L5
XZCC8FCM30S
XZCC12FCM40B
XZCC20FCM30B
Other versions: please consult our Customer Care Centre.
27
OsiSense XS Inductive proximity sensors - Application
Rotation control Fixed sensing distance
(for ferrous or non ferrous materials)
Non flush mountable
Flush mountable
26 x 26 x 13 40 x 40 x 15 M30 M18 M30
Nominal sensing distance Sn
Operating zone (mm)
Suitability for flush mounting (metal environment)
Case M (metal) P (plastic)
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Product certification
Dimensions (mm) Ø x L or W x H x D Cable (Connector)
Maximum speed of passing object (impulses/min)
Adjustable frequency range (impulses/min)
10 mm
0...8
flush mountable
P
- 25…+ 70
15 mm
0...12
P
IP 67
CE - UL - CSA - CCC - C-TICK
26 x 26 x 13
48000
6...6000
40 x 40 x 15
48000
6...6000
10
M
mm
0...8
5 mm
0...4
flush mountable
M
0…+ 50
10 mm
0...8
M pre-cabled: IP 68 (with connector: IP 67)
CE - UL - CSA - CCC - C-TICK
M30 x 81
6000...48000 (1)
6...150 / 120...3000 (1) –
M18 x 60 (M18 x 70) M30 x 60
– –
–
Sensors for DC applications
Connection
4-wire
3-wire
Connection
4-wire
3-wire
PNP/NPN NO/NC
PNP NC function
0…10 V output
4…20 mA output programmable slow version fast version
PNP/NPN NO/NC programmable
PNP NC function
0…10 V output
4…20 mA output
Supply voltage limits, min./max. (V) including ripple
Pre-cabled, PvR (2 m)
– plastic metal, flush mountable plastic, flush mountable – plastic, non flush mountable –
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XSAV11373
XSAV12373
–
–
–
M8 or M12 connector
– – –
XS9E11RPBL01M12 (3) XS9C11RPBL01M12 (3) –
10...36
–
–
10...36
–
–
10...58
Switching capacity, max. (mA) 100 200 200
Short-circuit protect. (g) / LED output state indicator (⊗) / Power on LED (⊗) (⊗)
Linearity error –
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Operating frequency (Hz)
≤ 2
–
– g
–
–
–
/ ⊗ / ⊗
≤ 2 g
–
/ ⊗ / ⊗
≤ 2
–
–
200 g / ⊗ / –
–
≤ 2.6
1000
– g / ⊗ / –
Multi-current/multi-voltage sensors for AC/DC applications
Connection
2-wire AC/DC NC function not short-circuit protected (2) NC function
Supply voltage limits, min./max. (V) 50-60 Hz
Switching capacity, max. (mA) slow version fast version
–
–
Pre-cabled, PvR (2 m)
XS9E11RMBL01U20 (5) XS9C11RMBL01U20 (5) –
20...264
–
–
20...264
XSAV11801
XSAV12801
20...264
100 300 AC / 200 DC 300 AC / 200 DC
LED output state indicator (⊗) / Power on LED (⊗)
Residual current, open state (mA)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
⊗ / ⊗
≤ 1.5
≤ 5.5
–
⊗ / ⊗
≤ 1.5
≤ 5.5
–
⊗ / –
≤ 1.5
≤ 5.7
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Accessories
Fixing for flat sensors flat
90° flat 90° substitution of block type sensors
XSE / XSC / XSD
8x22x8
15x32x8
XSZBJ00
XSZBF00
XSZBJ90 –
XSZBF90 XSZBE10
26x26x13 XSZBE00 XSZBE90 XSZBC10
40x40x15 XSZBC00 XSZBC90 XSZBD10
Fixing clamp with indexing pin for cylindrical sensors
M12 XSZB112
M18 XSZB118
M30 XSZB130
Other versions: please consult our Customer Care Centre.
28
Inductive proximity sensors - Application
Rotation control Analogue (Position control)
26 x 26 x 13 40 x 40 x 15 M30 M18 M30
Nominal sensing distance Sn
Operating zone (mm)
Suitability for flush mounting (metal environment)
Case M (metal) P (plastic)
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Product certification
Dimensions (mm) Ø x L or W x H x D Cable (Connector)
Maximum speed of passing object (impulses/min)
Adjustable frequency range (impulses/min)
10 mm
0...8
flush mountable
P
- 25…+ 70
15 mm
0...12
P
IP 67
CE - UL - CSA - CCC - C-TICK
26 x 26 x 13
48000
6...6000
40 x 40 x 15
48000
6...6000
10
M
mm
0...8
5 mm
0...4
flush mountable
M
0…+ 50
10 mm
0...8
M pre-cabled: IP 68 (with connector: IP 67)
CE - UL - CSA - CCC - C-TICK
M30 x 81
6000...48000 (1)
6...150 / 120...3000 (1) –
M18 x 60 (M18 x 70) M30 x 60
– –
–
Sensors for DC applications
Connection
4-wire
3-wire
Connection
4-wire
3-wire
PNP/NPN NO/NC
PNP NC function
0…10 V output
4…20 mA output programmable slow version fast version
PNP/NPN NO/NC programmable
PNP NC function
0…10 V output
4…20 mA output
Supply voltage limits, min./max. (V) including ripple
Pre-cabled, PvR (2 m)
– plastic metal, flush mountable plastic, flush mountable – plastic, non flush mountable –
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XSAV11373
XSAV12373
–
–
–
M8 or M12 connector
– – –
XS9E11RPBL01M12 (3) XS9C11RPBL01M12 (3) –
10...36
–
–
10...36
–
–
10...58
Switching capacity, max. (mA) 100 200 200
Short-circuit protect. (g) / LED output state indicator (⊗) / Power on LED (⊗) (⊗)
Linearity error –
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Operating frequency (Hz)
≤ 2
–
– g
–
–
–
/ ⊗ / ⊗
≤ 2 g
–
/ ⊗ / ⊗
≤ 2
–
–
200 g / ⊗ / –
–
≤ 2.6
1000
– g / ⊗ / –
Multi-current/multi-voltage sensors for AC/DC applications
Connection
2-wire AC/DC NC function not short-circuit protected (2) NC function
Supply voltage limits, min./max. (V) 50-60 Hz
Switching capacity, max. (mA) slow version fast version
–
–
Pre-cabled, PvR (2 m)
XS9E11RMBL01U20 (5) XS9C11RMBL01U20 (5) –
20...264
–
–
20...264
XSAV11801
XSAV12801
20...264
100 300 AC / 200 DC 300 AC / 200 DC
LED output state indicator (⊗) / Power on LED (⊗)
Residual current, open state (mA)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
⊗ / ⊗
≤ 1.5
≤ 5.5
–
⊗ / ⊗
≤ 1.5
≤ 5.5
–
⊗ / –
≤ 1.5
≤ 5.7
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
Accessories
Fixing for flat sensors Fixing clamp with indexing pin for cylindrical sensors flat 90° substitution of block type sensors
XSE / XSC / XSD
8x22x8
15x32x8
XSZBJ00
XSZBF00
XSZBJ90 –
XSZBF90 XSZBE10
26x26x13 XSZBE00 XSZBE90 XSZBC10
40x40x15 XSZBC00 XSZBC90 XSZBD10
M12 XSZB112
M18 XSZB118
M30 XSZB130
8 x 32 x 8 26 x 26 x 13
5 mm
1...4
10 mm
1...10
flush mountable
P flush mountable
P
- 25…+ 60 - 25…+ 70 pre-cabled: IP 68 (with connector: IP 67)
–
–
CE - UL - CSA - CCC - C-TICK
15 x 32 x 8 26 x 26 x 13
–
–
40 x 40 x 15
15 mm
2...15
flush mountable
P
- 25…+ 70
40 x 40 x 15
–
–
80 x 80 x 26
40 mm
5...40
flush mountable
P
- 25…+ 70
80 x 80 x 26
–
–
M12 M18 M30
M: 2 mm / P: 4 mm M: 5 mm / P: 8 mm M: 10 mm / P: 15 mm
M: 0.2…2 / P: 0.4…4 M: 0.5…5 / P: 0.8…8 M: 1…10 / P: 1.5…15 flush / non flush mountable flush / non flush mountable flush / non flush mountable
M or P M or P M or P
- 25…+ 70
IP 67
- 25…+ 70 - 25…+ 70
Ø 12 x 50
–
–
Ø 18 x 50
–
–
Ø 30 x 52.5
–
–
–
–
–
XS9F111A1L2
–
XS9F111A2L2
–
–
–
–
XS9E111A1L2
–
XS9E111A2L2
–
–
–
–
XS9C111A1L2
–
XS9C111A2L2
–
–
–
–
XS9D111A1L2
–
XS9D111A2L2
–
M8 or M12 connector
–
–
–
–
–
–
–
–
XS9F111A1L01M8 (4) XS9E111A1L01M12 (4) XS9C111A1L01M12 (4) XS9D111A1M12
XS9F111A2L01M8 (4) XS9E111A2L01M12 (4) XS9C111A2L01M12 (4) XS9D111A2M12
10...36
10...36
10...36
10...36
–
–
–
–
–
–
10…38
–
–
–
XS4P12AB110
XS1M12AB120
–
XS4P12AB120
–
–
–
–
–
–
10…38
–
–
–
XS4P18AB110
XS1M18AB120
–
XS4P18AB120
–
–
–
–
–
–
10…38
–
–
–
XS4P30AB110
XS1M30AB120
–
XS4P30AB120
–
–
–
–
–
–
–
–
± 1 V for 0…10 V version / ± 2 mA for 4…20 mA version
–
–
2000
–
–
1000
–
–
1000
–
–
100
–
–
1500
–
–
500
–
–
300
(1) 6...150 and 6000 impulses/min for XSAV11373 and XSAV11801 (slow version); 120...3000 and 48000 impulses/min for XSAV12373 and XSAV12801 (fast version).
(2) For these sensors without short-circuit protection, it is essential to connect a 0.4 A quick-blow fuse in series with the load.
(3) Flying lead (L = 0.15 m) with end mounted remote control incorporating M12 connector.
(4) Flying lead (L = 0.15 m) with end connector.
(5) Flying lead (L = 0.15 m) with end mounted remote control incorporating 1/2"-20 UNF connector.
Accessories
PUR pre-wired connectors (1)
Straight Elbowed
(1) For PVC cable see page 47
M8 (3 pin)
Straight Elbowed
1/2"
Straight Elbowed
M12 (4 pin)
Straight Elbowed Elbowed PNP LED
2 m XZCP0566L2 XZCP0666L2
5 m XZCP0566L5 XZCP0666L5
2 m
5 m
XZCP1865L2 XZCP1965L2
XZCP1865L5 XZCP1965L5
2 m
5 m
XZCP1141L2 XZCP1241L2 XZCP1340L2
XZCP1141L5 XZCP1241L5 XZCP1340L5
10 m XZCP0566L10 XZCP0666L10 10 m XZCP1865L10 XZCP1965L10 10 m XZCP1141L10 XZCP1241L10 XZCP1340L10
Suitable female plug-in connectors
M8
Steel ring
Straight
XZCC8FDM30S
M12 (4 pin)
Steel ring XZCC12FDM40B
Plastic ring XZCC12FDP40B
Elbowed
XZCC8FCM30S
XZCC12FCM40B
XZCC12FCP40B
Other versions: please consult our Customer Care Centre.
29
OsiSense XS Inductive proximity sensors - Application
Food and beverage processing
Type M12 M18 Ø 18 plain M30
Nominal sensing distance Sn
Operating zone (mm)
Suitability for flush mounting (metal environment)
Case M (metal) (1)
Product certification
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
7 mm
0 …5.6
12 mm
0 … 9.6
12 mm
0 … 9.6
non flush mountable
M stainless steel 316 L
CE - UL - CSA - CCC - C-TICK
- 25…+ 85 pre-cabled: IP 68 (with connector: IP 67) and IP 69K conforming to DIN 40050
22 mm
0 … 17.6
Sensors for DC applications
(solid-state output: transistor)
Connection
Dimensions (mm)
3-wire PNP
NPN
NO function
NO function
Connection
Dimensions (mm)
3-wire PNP
NPN
NO function
NO function
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA)
Switching frequency (Hz)
Short-circuit protection (g) / LED output state indicator (⊗)
Voltage drop, closed state (V) at I nominal
Pre-cabled, non poisonous PVC (2 m)
M12 x 55 M18 x 60
XS212SAPAL2
XS212SANAL2
M12 connector
M12 x 61
XS218SAPAL2
XS218SANAL2
M18 x 70
XS212SAPAM12
XS212SANAM12
10…36
≤ 200
XS218SAPAM12
XS218SANAM12
2500 g / ⊗
≤ 2
1000 g / ⊗
Ø 18 x 60
XS2L2SAPAL2
XS2L2SANAL2
Ø 18 x 70
XS2L2SAPAM12
XS2L2SANAM12
1000 g / ⊗
M30 x 62
XS230SAPAL2
XS230SANAL2
M30 x 70
XS230SAPAM12
XS230SANAM12
500 g / ⊗
Multi-current/multi-voltage sensors for AC/DC applications
Connection
Dimensions (mm)
2-wire (2)
Connection
Dimensions (mm)
AC/DC NO function
2-wire (2) AC/DC
Supply voltage limits, min./max. (V) 50-60 HZ
NO function
Switching capacity, max. (mA)
Switching frequency (Hz)
LED output state indicator (⊗)
–
–
–
–
–
Pre-cabled, non poisonous PVC (2 m)
– M18 x 60
–
1/2"-20 UNF connector
–
XS218SAMAL2
M18 x 72
XS218SAMAU20
20 … 264
300 AC / 200 DC
25 AC / 1000 DC
⊗
Voltage drop, closed state (V) at I nominal
Residual current, open state (mA)
–
–
(1) Plastic range available. M12, M18, M30:
To order, replace the second letter S in the reference by A
(example: XS212 SAPAL2 becomes XS212AAPAL2).
–
–
–
–
–
–
–
–
M30 x 62
XS230SAMAL2
M30 x 74
XS230SAMAU20
20 … 264
300 AC / 200 DC
25 AC / 300 DC
⊗
≤
≤
5.5
0.8
–
–
≤
≤
5.5
0.8
(2) For these sensors without short-circuit protection, it is essential to connect a
0.4 A quick-blow fuse in series with the load.
Accessories
Fixing clamps
Plastic fixing centres 24.1 mm, with locking screw for sensor
Ø 18 plain XUZB2005
M12 pre-wired connector female, 4-pin, stainless steel clamping ring
Straight connector 5 m cable XZCPA1141L5
M12 jumper cable male, 3-pin, stainless steel clamping ring
Straight connector 5 m XZCRA151140A5
Stainless steel for sensor
Ø 12
Ø 18
Ø 30
XSZBS12
XUZA118
XSZBS30
Elbowed connector 5 m cable XZCPA1241L5 1/2" pre-wired connector
Straight
Elbowed
5 m
5 m
XZCP1865L5
XZCP1965L5
Other versions: please consult our Customer Care Centre.
30
OsiSense XT Capacitive proximity sensors
Detection of insulating materials or conductive materials
Non flush mountable
(plastic)
Flush mountable
(metal)
Suitability for flush mtg. M12 M18 M30 Ø 32
Nominal sensing distance Sn
Operating zone Sa (mm) (2)
Case M (metal) P (plastic)
Product certification
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Dimensions (mm) Ø x L or H x W x D flush mountable non flush mountable flush mountable non flush mountable flush mountable non flush mountable
2 mm
–
0…1.44
–
M
–
CE
- 25…+ 70
IP 67
M12 x 70
5 mm
8 mm
0…3.6
0…5.8
M
P
M18 x 80
10 mm
15 mm
0…7.2
0…11
M
P
M30 x 80
15 mm
20 mm
0…10
0…15
M
P
M32 x 80
Sensors for DC applications
Connection
3-wire PNP
NPN
NO function
NO + NC functions
NO function flush mountable non flush mountable flush mountable non flush mountable flush mountable non flush mountable
Connection
3-wire PNP NO + NC functions flush mountable non flush mountable
NPN NO + NC functions flush mountable
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA)
Short circuit-protection (g) / LED output state indicator (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Pre-cabled, PVC (2 m)
XT112S1PAL2 XT118B1PAL2
–
XT112S1PCL2
XT218A1PAL2
XT118B1PCL2
–
XT112S1NAL2
–
M12 connector
–
XT118B1NAL2
XT218A1NAL2
XT112S1PCM12
–
–
10...38
XT118B1PCM12
XT218A1PCM12
–
200 g / ⊗
≤ 2
300
XT130B1PAL2
XT230A1PAL2
XT130B1PCL2
–
XT130B1NAL2
XT230A1NAL2
XT130B1PCM12
XT230A1PCM12
–
–
–
–
100 (XT2) / 200 (XT1) 100 (XT2) / 150 (XT1) –
–
–
–
–
–
–
Multi-current/multi-voltage sensors for AC applications
Connection
2-wire AC (1) NO function
NC function flush mountable non flush mountable flush mountable non flush mountable
–
–
Pre-cabled, PVC (2 m)
– XT118B1FAL2
–
XT218A1FAL2
XT118B1FBL2
–
XT130B1FAL2
XT230A1FAL2
XT130B1FBL2
XT230A1FBL2
XT132B1FAL2
XT232A1FAL2
XT132B1FBL2
XT232A1FBL2
Connection
2-wire AC (1) NO or NC programmable flush mountable
Supply voltage limits, min./max. (V) 50-60 Hz
Switching capacity, max. (mA)
LED output state indicator (⊗) / Power on LED (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Screw terminals
–
–
–
⊗ / –
–
–
–
20…264
300
≤ 5.5
25
XT230A2MDB (4) –
20…264
≤ 5.5
25
(1) For these sensors without short-circuit protection, it is essential to connect a 0.4 A quick-blow fuse in series with the load.
(2) The operating distance depends on the objet material.
(3) Only for detecting insulating materials. (4) 24…240 VAC or 24 VDC supply (non flush mountable)
20…264
≤ 9
25
Accessories
Suitable female plug-in connectors, including PUR pre-wired versions (1) length 5 m without LED pre-wired, elbowed pre-wired, straight screw terminal
40 x 40 x 117
15 mm
–
0…11
–
P
–
CE - UL - CSA
117 x 40 x 40
–
–
–
–
–
–
Screw terminals
XT7C40PC440 (3)
–
XT7C40NC440 (3)
10...58
200 g / ⊗
≤ 2
100
–
–
–
–
XT7C40FP262
20…264
350
≤ 5.5
25
M12
(1) For PVC cable see page 47
XZCP1241L5 XZCP1141L5 XZCC12FCM40B
Other versions: please consult our Customer Care Centre.
31
OsiSense XU
NO function:
Thru-beam
Object present / Output ON
Reflex Diffuse
Photo-electric sensors
General Purpose
(T) (R) (T/R) (T/R)
NC function: No object present / Output ON
Thru-beam Reflex Diffuse
(T) (R) (T/R) (T/R)
Diffuse
Reflex Polarised
Reflex
Thru beam
Output function
Multimode
Sensing distance
Output type DC3 NO
AC/DC 1C/O relay
Sensing distance (4)
Output type DC3 NO PNP
AC/DC 1C/O relay
Sensing distance (4)
Output type DC3 NO PNP
AC/DC 1C/O relay
Sensing distance
Output type DC3 NO
Thru beam Transmitter
AC/DC 1C/O relay
NO
NC
Sensing distance
Output type DC3 NO/NC
PNP
NPN
NPN
NPN
PNP
NPN
DC
AC/DC
PNP
M18 Metal (1)
Cable
0.6
m (2) (3)
XUB5BPANL2
XUB5BNANL2
–
2 m
XUB9BPANL2
XUB9BNANL2
–
4 m
XUB1BPANL2
XUB1BNANL2
–
15 m
XUB2BPANL2R
XUB2BNANL2R
–
A
B
XUB2BKSNL2T
M12 connector
XUB5BPANM12
XUB5BNANM12
–
XUB9BPANM12
XUB9BNANM12
–
XUB1BPANM12
XUB1BNANM12
–
XUB2BPANM12R
XUB2BNANM12R
–
A
B
XUB2BKSNM12T
–
Background suppression:
–
0.12
m - Diffuse: 0.3
m
Reflex polarised:
XUB0BPSNL2
3 m - Thru beam: 20 m
XUB0BPSNM12
Thru beam Transmitter
AC/DC 1C/O relay
NPN
PNP/NPN
DC
XUB0BNSNL2
–
–
XUB0BKSNL2T
AC/DC –
(1) Brass metal, aivailable also in stainless steel, see page food/beverage processing series
XUB0BNSNM12
–
–
XUB0BKSNM12T
–
M18 Plastic
Cable
0.6
m (2) (3)
XUB5APA NL2
XUB5ANANL2
–
2 m
XUB9APANL2
XUB9ANANL2
–
4 m
XUB1APANL2
XUB1ANANL2
–
15 m
XUB2APANL2R
XUB2ANANL2R
–
A
B
XUB2AKSNL2T
–
–
–
XUB0APSNL2
XUB0ANSNL2
XUB0AKSNL2T
–
M12 connector
XUB5APANM12
XUB5ANANM12
–
XUB9APANM12
XUB9ANANM12
–
XUB1APANM12
XUB1ANANM12
–
XUB2APANM12R
XUB2ANANM12R
–
A
B
XUB2AKSNM12T
–
–
–
XUB0APSNM12
XUB0ANSNM12
XUB0AKSNM12T
–
(2) For a sensing distance 0,1 m without sensitivity adjustment, change digit 5 by 4 into the reference (ex: XUB 5BPANL2 becomes XUB4BPANL2)
Fixing M18 x1 M18 x1
Dimensions
Product certifications
M18 x 64 mm / M18 x 78 mm
CE, UL, CSA, C-Tick CE, UL, CSA, C-Tick
DC common characteristics
Supply voltage limits, min./max. (V) including ripple 10…36
Switching frequency (Hz) 500
10…36
500
Common characteristics for DC versions Switching capacity, max. (mA): 100 / Overload and short-circuit protection (g) / LED output state
AC/DC common characteristics
Supply voltage limits, min./max. (V) including ripple –
Switching frequency (Hz)
LED output state indicator (⊗) / power on LED (⊗)
–
–
–
–
–
Accessories
Reflectors
XUZC24 XUZC80
32
XUZC50
Reflectors (mm)
Ø 21
24 x 21
11 x 33
Ø 39
XUZC21
XUZC24
XUZC08
XUZC39
Ø 80
50 x 50
XUZC80
XUZC50
100 x 100 XUZC100
3D fixings with ball joint
Bracket with ball joint for sensors and reflector
XUZC50 for
XUB… XUZB2003
XUM0… XUZM2003
XUK… XUZK2003
XUX… XUZX2003
Protective housing with ball joint for
XUK… XUZK2004
XUX… XUZX2004
M12 rod for ball joint
XUZ2001
Other versions: please consult our Customer Care Centre.
Miniature
Cable
1 m (3)
XUM5APCNL2
XUM5ANCNL2
–
5 m (3)
XUM9APCNL2
XUM9ANCNL2
–
–
–
–
–
15 m (3)
XUM2APCNL2R
XUM2ANCNL2R
–
NO or NC
–
–
–
M8 connector
XUM5APCNM8
XUM5ANCNM8
–
XUM9APCNM8
XUM9ANCNM8
–
XUM2APCNM8R
XUM2ANCNM8R
–
NO or NC
XUM2AKCNL2T XUM2AKCNM8T
–
Background suppression:
–
0.1
m - Diffuse: 0.4
m
Reflex polarised: 3 m - Thru beam: 10 m
XUM0APSAL2 XUM0APSAM8
XUM0ANSAL2
–
–
XUM0AKSAL2T
–
(3) With sensitivity adjustment
XUM0ANSAM8
–
–
XUM0AKSAM8T
–
(4) With reflector XUZC50 to be ordered separatly
Direct fixing centres 25.5, M3 screws
12 x 34 x 20
CE, UL, CSA, C-Tick
–
–
–
10…30
1000 indicator (⊗): yes / power on LED (⊗): yes
Compact 50 x 50 mm
Cable
1 m (3)
XUK5APANL2
XUK5ANANL2
XUK5ARCNL2
5 m
XUK9APANL2
XUK9ANANL2
XUK9ARCNL2
7 m
XUK1APANL2
XUK1ANANL2
XUK1ARCNL2
30 m
XUK2APANL2R
XUK2ANANL2R
XUK2ARCNL2R
A
B
XUK2AKSNL2T
M12 connector
XUK5APANM12
XUK5ANANM12
–
XUK9APANM12
XUK9ANANM12
–
XUK1APANM12
XUK1ANANM12
–
XUK2APANM12R
XUK2ANANM12R
–
A
B
XUK2AKSNM12T
XUK2ARCNL2T
Background suppression:
Reflex polarised:
–
–
0.28
4 m - Thru beam: 30 m
–
m - Diffuse: 0.8
m
–
XUK0AKSAL2
XUK0ARCTL2
XUK0AKSAL2T
XUK0ARCTL2T
–
XUK0AKSAM12
–
XUK0AKSAM12T
–
Direct fixing centres 40 x 40, M4 screws
18 x 50 x 50
CE, UL, CSA, CCC, C-Tick
10…30
500
20…264
20
⊗ / ⊗
Compact 92 x 71 mm
Screw terminal
2.1
m (3)
XUX5AP ANT16
XUX5ANANT16
XUX5ARCNT16
11 m (3)
XUX9AP ANT16
XUX9ANANT16
XUX9ARCNT16
14 m (3)
XUX1AP ANT16
XUX1ANANT16
XUX1ARCNT16
40 m (3)
XUX2AP ANT16R
XUX2ANANT16R
XUX2ARCNT16R
A
B
XUX0AKSAT16T
M12 connector
XUX5AP ANM12
XUX5ANANM12
–
XUX9AP ANM12
XUX9ANANM12
–
XUX1AP ANM12
XUX1ANANM12
–
XUX2AP ANM12R
XUX2ANANM12R
–
A
B
XUX0AKSAM12T
XUX0ARCTT16T
Background suppression:
–
1.3
m - Diffuse: 2 m
Reflex polarised: 11 m - Thru beam: 40 m
– –
–
XUX0AKSAT16
XUX0ARCTT16
XUX0AKSAT16T
XUX0ARCTT16T
–
XUX0AKSAM12
–
XUX0AKSAM12T
–
Direct fixing centres 30/38 to 40/50/74, M5 screws
30 x 92 x 71
CE, UL, CSA, CCC, C-Tick
10…36
500
20…264
20
⊗ / ⊗
Photo-electric sensors
General Purpose
Diffuse
Reflex Polarised
Reflex
Thru beam
Output function
Multimode
Sensing distance
Output type DC3 NO
AC/DC 1C/O relay
Sensing distance (4)
Output type DC3 NO PNP
AC/DC 1C/O relay
Sensing distance (4)
Output type DC3 NO PNP
AC/DC 1C/O relay
Sensing distance
Output type DC3 NO
Thru beam Transmitter
AC/DC 1C/O relay
NO
NC
Sensing distance
Output type DC3 NO/NC
PNP
NPN
NPN
NPN
PNP
NPN
DC
AC/DC
PNP
M18 Metal (1)
Cable
0.6
m (2) (3)
XUB5BPANL2
XUB5BNANL2
–
2 m
XUB9BPANL2
XUB9BNANL2
–
4 m
XUB1BPANL2
XUB1BNANL2
–
15 m
XUB2BPANL2R
XUB2BNANL2R
–
A
B
XUB2BKSNL2T
M12 connector
XUB5BPANM12
XUB5BNANM12
–
XUB9BPANM12
XUB9BNANM12
–
XUB1BPANM12
XUB1BNANM12
–
XUB2BPANM12R
XUB2BNANM12R
–
A
B
XUB2BKSNM12T
–
Background suppression:
Reflex polarised:
XUB0BPSNL2
–
0.12
m - Diffuse:
3 m - Thru beam: 20 m
XUB0BPSNM12
0.3
m
Thru beam Transmitter
AC/DC 1C/O relay
NPN
PNP/NPN
DC
XUB0BNSNL2
–
–
XUB0BKSNL2T
AC/DC –
(1) Brass metal, aivailable also in stainless steel, see page food/beverage processing series
XUB0BNSNM12
–
–
XUB0BKSNM12T
–
M18 Plastic
Cable
0.6
m (2) (3)
XUB5APA NL2
XUB5ANANL2
–
2 m
XUB9APANL2
XUB9ANANL2
–
4 m
XUB1APANL2
XUB1ANANL2
–
15 m
XUB2APANL2R
XUB2ANANL2R
–
A
B
XUB2AKSNL2T
–
–
–
XUB0APSNL2
XUB0ANSNL2
XUB0AKSNL2T
–
M12 connector
XUB5APANM12
XUB5ANANM12
–
XUB9APANM12
XUB9ANANM12
–
XUB1APANM12
XUB1ANANM12
–
XUB2APANM12R
XUB2ANANM12R
–
A
B
XUB2AKSNM12T
–
–
–
XUB0APSNM12
XUB0ANSNM12
XUB0AKSNM12T
–
(2) For a sensing distance 0,1 m without sensitivity adjustment, change digit 5 by 4 into the reference (ex: XUB 5BPANL2 becomes XUB4BPANL2)
Fixing M18 x1 M18 x1
Dimensions
Product certifications
M18 x 64 mm / M18 x 78 mm
CE, UL, CSA, C-Tick CE, UL, CSA, C-Tick
DC common characteristics
Supply voltage limits, min./max. (V) including ripple 10…36
Switching frequency (Hz) 500
10…36
500
Common characteristics for DC versions Switching capacity, max. (mA): 100 / Overload and short-circuit protection (g) / LED output state
AC/DC common characteristics
Supply voltage limits, min./max. (V) including ripple –
Switching frequency (Hz)
LED output state indicator (⊗) / power on LED (⊗)
–
–
–
–
–
3D fixings with ball joint
Miniature
Cable
1 m (3)
XUM5APCNL2
XUM5ANCNL2
–
5 m (3)
XUM9APCNL2
XUM9ANCNL2
–
–
–
–
–
15 m (3)
XUM2APCNL2R
XUM2ANCNL2R
–
NO or NC
M8 connector
–
–
–
XUM5APCNM8
XUM5ANCNM8
–
XUM9APCNM8
XUM9ANCNM8
–
XUM2APCNM8R
XUM2ANCNM8R
–
NO or NC
XUM2AKCNL2T XUM2AKCNM8T
–
Background suppression:
–
0.1
m - Diffuse: 0.4
m
Reflex polarised: 3 m - Thru beam: 10 m
XUM0APSAL2 XUM0APSAM8
XUM0ANSAL2
–
–
XUM0AKSAL2T
–
(3) With sensitivity adjustment
XUM0ANSAM8
–
–
XUM0AKSAM8T
–
(4) With reflector XUZC50 to be ordered separatly
Direct fixing centres 25.5, M3 screws
12 x 34 x 20
CE, UL, CSA, C-Tick
–
–
–
10…30
1000 indicator (⊗): yes / power on LED (⊗): yes
Compact 50 x 50 mm
Cable
1 m (3)
XUK5APANL2
XUK5ANANL2
XUK5ARCNL2
5 m
XUK9APANL2
XUK9ANANL2
XUK9ARCNL2
7 m
XUK1APANL2
XUK1ANANL2
XUK1ARCNL2
30 m
XUK2APANL2R
XUK2ANANL2R
XUK2ARCNL2R
A
B
XUK2AKSNL2T
M12 connector
XUK5APANM12
XUK5ANANM12
–
XUK9APANM12
XUK9ANANM12
–
XUK1APANM12
XUK1ANANM12
–
XUK2APANM12R
XUK2ANANM12R
–
A
B
XUK2AKSNM12T
XUK2ARCNL2T
Background suppression:
Reflex polarised:
–
–
0.28
4 m - Thru beam: 30 m
–
m - Diffuse: 0.8
m
–
XUK0AKSAL2
XUK0ARCTL2
XUK0AKSAL2T
XUK0ARCTL2T
–
XUK0AKSAM12
–
XUK0AKSAM12T
–
Direct fixing centres 40 x 40, M4 screws
18 x 50 x 50
CE, UL, CSA, CCC, C-Tick
10…30
500
20…264
20
⊗ / ⊗
Compact 92 x 71 mm
Screw terminal
2.1
m (3)
XUX5AP ANT16
XUX5ANANT16
XUX5ARCNT16
11 m (3)
XUX9AP ANT16
XUX9ANANT16
XUX9ARCNT16
14 m (3)
XUX1AP ANT16
XUX1ANANT16
XUX1ARCNT16
40 m (3)
XUX2AP ANT16R
XUX2ANANT16R
XUX2ARCNT16R
A
B
XUX0AKSAT16T
M12 connector
XUX5AP ANM12
XUX5ANANM12
–
XUX9AP ANM12
XUX9ANANM12
–
XUX1AP ANM12
XUX1ANANM12
–
XUX2AP ANM12R
XUX2ANANM12R
–
A
B
XUX0AKSAM12T
XUX0ARCTT16T
Background suppression:
–
1.3
m - Diffuse: 2 m
Reflex polarised: 11 m - Thru beam: 40 m
– –
–
XUX0AKSAT16
XUX0ARCTT16
XUX0AKSAT16T
XUX0ARCTT16T
–
XUX0AKSAM12
–
XUX0AKSAM12T
–
Direct fixing centres 30/38 to 40/50/74, M5 screws
30 x 92 x 71
CE, UL, CSA, CCC, C-Tick
10…36
500
20…264
20
⊗ / ⊗
Fixing support for
M12 rod
Simple fixings
Single bracket
XUZ2003 for standard with ball joint
XUB...
XUZA118 (stnls. steel) XUZA218 (plastic)
XUM...
XUZAM02
XUK...
XUZA51
XUX...
XUZX2000
–
–
–
Suitable female plug-in connectors, including PUR pre-wired versions (1) length 5 m without LED
M8
M12 pre-wired, elbowed
XZCP1041L5
XZCP1241L5
(1) For PVC cable see page 47 pre-wired, straight
XZCP0941L5
XZCP1141L5 screw terminal
XZCC8FCM40S
XZCC12FCM40B
Other versions: please consult our Customer Care Centre.
33
OsiSense XU Photo-electric sensors
Optical forks without setting and frames
System Thru-beam with modular red LED light source
Sensing distance
Minimum size of objet detected
Case M (metal)
30…150
0,8 mm
M mm
Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 10…+ 60 / IP65 & IP67
Product certification CE - cULus
Sensors for DC applications
(solid-state output: transistor)
Connection
Dimensions (mm)
Transmitter / Receiver 3 wire NO function PNP
M8 connector 3-pin
Output function
D
D
B
B
A C
A C
NO
NC
NO function
NO function
NO function
NO function
NO function
NO function
NO function
Supply voltage limits, min./max. (V) including ripple
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
PNP
PNP
PNP
XUVR0605P ANM8
XUVR0605NANM8
XUVR0608P ANM8
XUVR0608NA NM8
XUVR1212P ANM8
XUVR1212NANM8
XUVR1218P ANM8
XUVR1218NANM8
XUVA0505P ANM8
XUVA0808P ANM8
XUVA1212P ANM8
XUVA1515P A NM8
A
B
10…30
Switching capacity, max. (mA) / Switching frequency (Hz) 100/4kHz
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
A
50
80
B
60
60
C
74
Pre-cabled L = 2 m.
D
77.5
XUVR0303PANL2
104 77.5
120 120 144 142
180 120 204 142
44
74
44
74
71 71
101 101
112 112 142 142
142 142 172 172
A
30
B
40
C
54
D
57,5
System Thru-beam with infrared emission
Passageway dimensions
Connection
30 x 30 mm
M8 (4 pin)
60 x 60 mm 200 x 120 mm
M12 (4 pin)
200 x 180 mm 200 x 250 mm
Minimum size of object to be detected Ø 2 mm
Ø 4 mm
Ø 10 mm
XUVF30M8
–
XUVF60M8
–
–
XUVF120M12
–
XUVF180M12
–
XUVF250M12
– – XUYFRS120S XUYFRS180S XUYFRS250S
4-wire, PNP and NPN Output function ON or OFF on passage of object, programmable Type and output function
Function type
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA) / Switching frequency (Hz)
Dynamic (XUVF30M8, XUVF60M8), Dynamic or static (XUVF120M12, XUVF180M12, XUVF250M12)
18…30
≤ 100 mA / 500 Hz
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
Accessories
Suitable female PUR pre-wired plug-in connectors (1)
M8 (3 pin)
For optical forks without setting
Straight Elbowed
Straight
2 m XZCP0566L2
5 m XZCP0566L5
Elbowed
XZCP0666L2
XZCP0666L5
(1) For PVC cable see page 47
M8 (4 pin)
For optical forks and frame with setting
Straight
2 m XZCP0941L2
5 m XZCP0941L5
Elbowed
XZCP1041L2
XZCP1041L5
M12 (4 pin)
For frame with setting
Straight
2 m XZCP1141L2
5 m XZCP1141L5
Elbowed
XZCP1241L2
XZCP1241L5
Other versions: please consult our Customer Care Centre.
34
Photo-electric sensors
Optical forks without setting and frames Forks with teach mode
(1)
System, with teach mode Thru-beam
Laser class
Thru-beam laser
Sensing distance
Fixing (mm)
Minimum size of objet detected
Case M (metal) / Setting-up assistance LEDs ⊗
2…120 mm
(see column E below)
0,2 mm
M / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 60 / IP 65
Product certification CE - cULus
2…120 mm
0,05 mm
Sensors for DC applications
(solid-state output: transistor)
Connection
Type of output
Dimensions (mm)
Transmitter / Receiver
E
D
B
A C
M8 connector - 4 Pin
3-wire PNP/NPN programmable NO/NC
XUYFANEP40002
XUYFANEP60002
XUYFANEP100002
XUYFANEP40005
XUYFANEP60005
XUYFANEP100005
XUYFANEP40015
XUYFANEP60015
XUYFANEP100015
XUYFANEP40030
XUYFANEP60030
XUYFANEP100030
XUYFANEP40050
XUYFANEP60050
XUYFANEP100050
XUYFANEP40080
XUYFANEP60080
XUYFANEP100080
XUYFANEP40120
XUYFANEP60120
XUYFANEP100120
10…30
A B C D E
2
2
2
5
5
42 32 57 14 XUYFALNEP40002
59 77 XUYFALNEP60002
95 110 XUYFALNEP100002
42 35 57 14 XUYFALNEP40005
59 77 XUYFALNEP60005
5 95 110 XUYFALNEP100005
15 42 45 57 27 XUYFALNEP40015
15 59
15 95
77
110
XUYFALNEP60015
XUYFALNEP100015
30 42 60 57 42 XUYFALNEP40030
30 59 77 XUYFALNEP60030
30 95 110 XUYFALNEP100030
50 42 80 57 40 XUYFALNEP40050
50 59
50 95
77
110
XUYFALNEP60050
XUYFALNEP100050
80 42 110 57 70 XUYFALNEP40080
80 59 77 XUYFALNEP60080
80 95 110 XUYFALNEP100080
120 42 150 57 110 XUYFALNEP40120
120 59
120 95
77
110
XUYFALNEP60120
XUYFALNEP100120
10…30 Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA) / Switching frequency (Hz) 100/10 kHz
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
(1) To order a fork without teach mode, delete A of the reference. Ex: XUYFANEP40002 becomes XUYFNEP40002
100/10 kHz g / ⊗
2
2
A B C D E
2 42 41 57 14
59
95
77
110
5
5
42 44 57 14
59 77
5 95 110
15 42 54 57 27
15 59
15 95
77
110
30 42 69 57 42
30 59 77
30 95 110
50 42 89 57 40
50 59
50 95
77
110
80 42 119 57 70
80 59 77
80 95 110
120 42 159 57 110
120 59
120 95
77
110
System
Sensing distance
Switching frequency (Hz)
Sensitivity adjustment
Connection
3 mm version
Case M (metal) / Setting-up assistance LEDs ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529)
Product certification
(1) : remote adjustment available.
Ultrasonic thru-beam
Special transparent labels
XUVU06M3PSNM8
1500 numeric potentiometer (1)
M8 (4 pin)
M / ⊗
+5…+ 55 / IP 65
CE
Thru-beam
For all other opaque labels
XUVE04M3PSNM8
10 000 numeric potentiometer (1)
- 20…+ 60 / IP 65
CE - cULus
Other versions: please consult our Customer Care Centre.
35
OsiSense XU Photo-electric sensors - Application
Assembly series
A B
Application
System
Sensing distance
Fixing (mm)
Laser class
Accurate detection or very long sensing distance
Thru-beam
100 m (2)
M18 x 1
Sensitivity adjustment Teach mode
Case M (metal) P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 10…+ 45°C
Degree of protection (conforming to IEC 60529)
Product certification
Dimensions (mm) Ø x L or H x W x D
IP 67
CE - UL - CSA
Ø 18 x 64
Sensors for DC applications
(solid-state output: transistor)
Connection
Transmitter / Receiver 3-wire PNP
Connection
Transmitter / Receiver 3-wire PNP
3-wire PNP
Pre-cabled
NO function –
Connector M12
NO function – programmable NO / NC XUBLAPCNM12
3-wire NPN programmable NO / NC XUBLANCNM12
Supply voltage limits, min./max. (V) including ripple 10…30
Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 1500
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
(1) Reflex and thru-beam systems also available.
(2) or min. size of object: 0.2 mm
(3) With specific reflector XUY1111, format 50 x 50 mm. To be ordered separately.
Robustness and compactness
Diffuse
0.07 m
M8 x 1
–
M / –
- 25…+ 55
IP 67
CE - cULus
Ø 8 x 40
PVR (2 m)
XUAH0515
M8 4-pin
XUAH0515S
–
–
10…30
100 / 700 g / ⊗
C
D
Laser class
Laser class
A B
Reflex Diffuse contrast
10…1000 mm (3) 40…150 mm
Direct, 2 M3 holes, fixing centres 24 mm
Teach mode
P
- 20…+ 60°C
IP 67
CE - cULus
35.8 x 12 x 20
–
–
XUYBCO929LSP
–
10…30
100 / 1000 g / ⊗
–
–
XUYPCCO929LSP
–
10…30
100 / 1000 g / ⊗
Application
Miniature series sensors
C D compact 50x50mm
Laser class
Laser class
System
Sensing distance
Fixing (mm)
Polarised reflex
Thru-beam Polarised reflex
Thru beam Back ground suppression
1…1.5 m (4) 4 m 12 m (7) 25 m
2 x Ø 3 holes / fixing centres 9.5 2 x Ø 4.3 holes / fixing centres 30
0.8 m
Potentiometer Potentiometer Teach mode Teach mode potentiometer Sensitivity adjustment
Case P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 50°C / IP 65 & IP 67 -20…+ 60°C / IP67 & IP69K
Product certification CE - cULus CE, Ecolab
Dimensions (mm) H x W x D 40 x 10 x 13.5
50 x 50 X 23
Diffuse
1.2 m
Teach mode
Sensors for DC applications (solid-state output: transistor)
Connection
PNP
NPN
PNP
NO function
NO function programmable NO / NC
Transmitter
Supply voltage limits, min./max. (V) including ripple
M8 connector (5) - 4 Pin
– XUYECO989
M12 connector - 4 pin
XUYBCO989SP XUYRCO989SP –
XUYBCO989SN XUYRCO989SN – – – –
XUK9LAPSMM12 (6) XUK2LAPSMM12R (6) XUK8LAPPNM12 (6) XUK5LAPSMM12 (6)
10…30
–
12…30
– –
XUK2LAKSMM12T (6) –
Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 500 100 / ≤ 2000 100 / ≤ 3500 100 / ≤ 1000
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
(4) 50 x 50 reflector included.
(5) For 2 m pre-cabled version, delete CO from the reference. (Example: XUYBCO989SP becomes XUYB989SP or XUYRCO989SP becomes XUYR989SP).
(6) Fixing braket: XUZA51S to be ordered separately
(7) With reflector XUZC50HP to be ordered separately
–
–
100 / ≤ 600
Other versions: please consult our Customer Care Centre.
36
Materials handling series - Conveying
Analogue output
E
Application
System
E
Analogue output
Position control
Diffuse Reflex
Laser class et class
Diffuse
E
Diffuse
High access gain for resistance to accumulation of dirt
Thru-beam
Sensing distance
Fixing (mm)
Dimensions (mm) Ø x L or H x W x D
0.20...0.80
86 x 27 x 83 m 0.20...30
93 x 42 x 95 m fixing ctrs: 30 - 11P cable gland 3 trous 5,8mm
(1)
Sensitivity adjustment
Product certification
– Teach mode
Case M (metal) P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗ P / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 60 / IP 67 - 20…+ 50 / IP67
CE - UL - CSA CE, cULus
0.20...6 m (2) 0.05...0.40 m 50 m
M18 x 1 M18 x 1
Potentiometer
M / ⊗
Potentiometer
M / ⊗
- 25…+ 55 / IP 67 - 25…+ 55 / IP 67
CE - UL - CSA CE - UL - CSA - C-TICK
M18 x 95 M18 x 95
Sensors for DC applications
Connection
Transmitter / Receiver
Screw terminals analogue 4-20 mA / 0-10 V XUJK803538 (3) analogue 4-20 mA – analogue 4-20mA + 1 PNP – analogue 4-20mA + 2 PNP –
Supply voltage limits, min./max. (V) including ripple 20…30
M12 connector - 5 pins
–
–
–
XUE1AA2NM12
18…30
–
–
–
XUE5AA2NM12
M12 connector
–
XU5M18AB20D
–
–
10…30
M12 connector
–
–
XU2M18AP20D (2)
–
10…30
Switching capacity, max. (mA) / Switching frequency (Hz) max: 20, min: 4 / 10000 100 / 38 (fast mode), 16 (slow mode) max: 20, min: 4 / 20 100 / 30
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗ g / ⊗ g / ⊗ g / ⊗
(1) with reflector XUZC250 to be ordered separately. (2) on white and grey object 0,2 … 6m, on black object 0,2 … 2,5m (3) With 3-wire PNP output.
F G
Application
System
Sensing distance
Minimum size of object
Fixing (mm)
Sensitivity adjustment
Case P (plastic) / Setting-up assistance LEDs ⊗
Temperature range (°C)
Product certification
Dimensions (mm) H x W x D
H Laser class
F G
Diffuse, analogue output
0-10 V
40...60 mm
1 mm
4-20 mA
80...300 mm
1.5 x 3.5 mm direct: 3 M4 holes, fixing centres 40 mm
Potentiometer
P / ⊗
0…+ 45°
CE - cULus
50 x 17 x 50
H
Diffuse
0...100 mm
85 mm direct on conveyor with specific fixing parts
No
Aluminium tube / x
- 25...+ 55°
CE - UL
Tube Ø 12 , variable length from
200 to 900 mm (example 415 mm)
Sensors for DC applications
(solid-state output: transistor)
Connection
Transmitter / Receiver 0…10 V
Supply voltage limits, min./max (V) including ripple
M12 connector
XUYPCO925L1ANSP
M12 connector
XUYPCO925L3ANSP
Remote M12 connector
XUY415N4HL03M12
18…28 18…30
3 mA / 0…10 V analogue output 3 mA / 4…20 mA analogue output 100 mA Switching capacity, max.
Switching frequency (Hz) 40
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
1000 g / ⊗
Accessories
Suitable female PUR pre-wired plug-in connectors (1) Female connectors Fixing for XUE
M8 straight
2 m XZCP0941L2
5 m XZCP0941L5
(1) For PVC cable see page 47
M12 straight
XZCP1141L2
XZCP1141L5
M8 elbowed
XZCP1041L2
XZCP1041L5
M12 elbowed
XZCP1241L2
XZCP1241L5
M12 (5 pin) straight XZCC12FCM50B For compact elbowed XZCC12FDM50B XUZA618
Other versions: please consult our Customer Care Centre.
37
OsiSense XU
H
I
Photo-electric sensors - Application
Packaging series
J
N
Application
System
Sensing distance
Fixing (mm)
Sensitivity adjustment
Case M (metal) P (plastic) / Setting-up assistance LEDs ⊗
H Contrast sensors
Diffuse
(with teach mode)
19 mm direct: fixing centres 40 x 40
Teach button
P / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 10…+ 55 / IP 65
Product certification CE - cULus
Dimensions (mm) Ø x L or H x W x D 50 x 15 x 50
Sensors for DC applications
(solid-state output: transistor)
Connection
Transmitter / Receiver 3-wire PNP
3-wire NPN
3-wire PNP / NPN
NO function
M12 connector
XUKR1PSMM12
NO function XUKR1NSMM12 programmable NO / NC –
Supply voltage limits, min./max. (V) including ripple 10…30
Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 5000
(1) Nominal sensing distance 50 m. Use between 10 and 20 cm, depending on application.
(2) 7 mm with XURZ02; 18 mm with XURZ01.
Diffuse
(with teach mode)
9 mm (2) direct: 21 x 28, M5 screws
Teach button
M / ⊗
- 10…+ 55 / IP 67
CE
96 x 31 x 64
M12 connector
–
–
XURK1KSMM12
10…30
200 / 10000
Colour sensors
Diffuse
0.02 m direct: fixing ctrs. 40x40
Teach button
P / ⊗
- 10…+ 55 / IP 65
CE - cULus
50 x 25 x 50
M12 connector - 8 pin
XUKC1PSMM12
XUKC1NSMM12
–
10…30
100 / 1500
Application
System
Sensing distance
Fixing (mm)
Sensitivity adjustment
Case M (metal) P (plastic) / Setting-up assistance LEDs ⊗
Luminescence sensors Detection of transparent materials
I J I J
Diffuse
(manual)
0.02…0.08
M18 x 1
Potentiometer
M / ⊗ m
Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55 / IP 67
Product certification CE - CSA - UL
Dimensions (mm) Ø x L or H x W x D Ø 18 x 95
Reflex
(potentiometer)
Reflex (with teach mode)
(50 x 50 reflector included)
0.1…2 m 0…1.4 m (4)
M3 holes, fixing centers 24 M18 x 1
1.5 m direct: fixing ctrs. 40 x 40
Potentiometer
P / ⊗
- 25...+ 55 / IP67
CE - cURus
33 x 20 x 11
Teach button
P / ⊗
0…+ 55 / IP 67
CE - UL - CSA - C-TICK
Ø 18 x 64
I J
- 25…+ 55 / IP 65
50 x 18 x 50
Sensors for DC applications
(solid-state output: transistor)
Connection
Transmitter / Receiver 3-wire PNP
3-wire NPN
3-wire PNP / NPN
Connection
Transmitter / Receiver 3-wire PNP
3-wire PNP
3-wire NPN
Pre-cabled, PVC (2 m) programmable NO / NC – programmable NO / NC – programmable NO / NC – fonction NO
M12 connector
XU5M18U1D programmable NO / NC – programmable NO / NC –
3-wire PNP / NPN programmable NO / NC –
Supply voltage limits, min./max. (V) including ripple 10…30
XUMTAPCNL2
XUMTANCNL2
–
M8 connector
–
XUMTAPCNM8 (3)
XUMTANCNM8
–
10…30
XUBTAPSNL2 (5)
XUBTANSNL2 (5)
–
M12 connector
–
XUBTAPSNM12 (5)
XUBTANSNM12 (5)
–
10…32
–
–
XUKT1KSML2
M12 connector
–
–
–
XUKT1KSMM12
10…30
Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 1000 100 / 1000 100 / 1000 100 / 1500
(3) also available with M12 remote connector with 0.3 m cable : replace M8 by L03M12.
(4) 0…0.8 m for versions with 90° head, to order replace the 8 e digit N by W. Example XUBTAPSNL2 becomes XUBTAPSWL2
(5) Also available in stainless steel for food and beverage processing applications. To order, replace the letter A by S in the ref. Example: XUBTAPSNL2 becomes XUBTSPSNL2.
Accessories
Suitable female plug-in connectors, including PUR pre-wired versions (1)
L = 5 m, without LED Wired, elbowed
M8 (or S) 4 pin
M12 (or D) 4 pin
XZCP0666L5
XZCP1241L5
M12 8 pin –
(1) For PVC cable see page 47
Wired, straight
XZCP0566L5
XZCP1141L5
XSZMCR03 (3 m)
Screw terminal
XZCC8FCM30S
XZCC12FCM40B
–
Lenses for colour mark
Lens for 18 mm sensing distance Lens for 7 mm sensing distance
XURZ01 XURZ02
Other versions: please consult our Customer Care Centre.
38
Food/beverage processing series
Application Stainless steel version for resistance to harsh agents
System
Sensing distance
Fixing (mm)
Polarised reflex
0.4…11 m (1)
2 x Ø 4.3 holes …
Background suppression
0.03…0.55 m
Thru-beam
0…15 m
Case M (metal) M (stainless steel 316L)
Temperature range (°C) / Degree of protection (conforming to IEC 60529) -20 … +60°C (100°C for cleaning and sterilization phase whilst not in service) / IP67, IP69K
Product certification
Dimensions (mm) H x W x D
CE, Ecolab
50 x 50 X 23
Sensors for DC applications
(solid-state output: transistor)
Connection
Transmitter / Receiver 4-wire PNP
M12 connector - 4 pin
XUK9SPSMM12 XUK8SPSMM12 XUK2SKSMM12T (transmitter)
XUK2SPSMM12R (receiver)
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA) / Switching frequency (Hz)
(1) With reflector XUZC100 to be ordered separately
10…30
100 / 600 100 / 400 100 / 500
System Multimode (3)
Sensing distance
Fixing (mm)
Case M (metal)
Temperature range (°C) / Degree of protection (conforming to IEC 60529)
Product certification
Dimensions (mm) Ø x L
(4)
M18 x 1
M (stainless steel)
CE - UL - CSA - C-TICK
Ø 18 x 64
Stainless steel version for resistance to harsh agents
Polarised reflex
50x50 mm reflector included (2)
3 / 2 m
M18 x 1
M (stainless steel)
- 25…+ 55 / IP 67
Ø 18 x 62
Diffuse (2)
0.15 / 0.10
M18 x 1
M (stainless steel)
- 25…+ 55 / IP 67
Ø 18 x 62 m
Thru-beam (2)
20 / 15 m
M18 x 1
M (stainless steel)
- 25…+ 55 / IP 67
Ø 18 x 64
Sensors for DC applications
(solid-state output: transistor)
Connection
Transmitter / Receiver 3-wire PNP
Pre-cabled, PvR (2 m) programmable NO / NC XUB0SPSNL2
Connection
3-wire NPN
Transmitter / Receiver 3-wire PNP
3-wire NPN
Thru-beam transmitter accessory programmable NO / NC XUB0SNSNL2
M12 connector programmable NO / NC programmable NO / NC XUB0SNSNM12 pre-cabled (2 m) XUB0SKSNL2T connector
Supply voltage limits, min./max. (V) including ripple
XUB0SPSNM12
XUB0SKSNM12T
10…36
XU9N18PP341
XU9N18NP341
XU9N18PP341D
XU9N18NP341D
–
–
10…30
XU5N18PP341
XU5N18NP341
XU5N18PP341D
XU5N18NP341D
–
–
10…30
XU2N18PP341
XU2N18NP341
XU2N18PP341D
XU2N18NP341D
Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 250 100 / 500 100 / 500
(2) Also available with 90° head. To order, add the letter W after the numbers 341 in the reference. Example: XU9N18PP341 becomes XU9N18PP341W or XU9N18PP341WD.
(3) Also available with 90° head, to order replace the 8 e digit N by W. Example XUB0SPSNL2 becomes XUB0SPSWL2
(4) Background suppression: 0.12 m - Diffuse: 0.3 m - Reflex polarised: 3 m - Thru beam: 20 m
Accessories
Pre-wired connectors
L = 5 m Elbowed
XZCPA1241L5
Straight
XZCPA1141L5
Ecolab reflector 50x50 (2)
XUZC50CR
Stainless steel fixing bracket
(2) Sensing distance for XUK9S: 3m with XUZC50CR or 6m with XUZC50.
Other versions: please consult our Customer Care Centre.
39
OsiSense XU Photo-electric sensors with background suppression
K P
Application
System
Sensing distance
Minium size of object
Fixing (mm)
Sensitivity adjustment
1.5…80
–
K
Background suppression mm
2 x Ø 3 holes / fxg. ctrs. 14.5
Potentiometer
Case P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 50 / IP 65 & IP 67
Product certification
Dimensions (mm) H x W x D
CE - cULus
32 x 13 x 20
Laser class
Laser class
P K
Diffuse with background suppression
Sensing distance 1 Sensing distance 2
10…60 mm
0.3 mm
30…110
0.7 mm
mm direct: 2 M3 holes, fixing centres 24 mm
Teach mode
P
- 20…+ 60°C / IP 67
CE - cULus
35.8 x 12 x 20
Sensors for DC applications
(solid-state output: transistor)
Connection
Transmitter / Receiver PNP
NPN
NO function
NO function
PNP programmable NO / NC
Supply voltage limits, min./max. (V) including ripple
M8 connector (1) - 4 Pin
XUYPSCO989SP
XUYPSCO989SN
–
10…30
Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 500
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
M8 connector- 4 Pin
–
–
XUYPSCO929L1SP
10…30
100 / 1000 g / ⊗
(1) For 2 m pre-cabled connection delete CO from the reference. Example: XUYPS CO989SP becomes XUYPS989SP.
M8 connector- 4 Pin
–
–
XUYPSCO929L2SP
10…30
100 / 1000 g / ⊗
L
M
Laser class
Application
System
Sensing distance
Minimum size of object
Fixing (mm)
Sensitivity adjustment
Background suppression
50…300
0.5 mm
mm direct: 2 M4 holes, ctrs. 54 mm
Potentiometer
Case P (plastic) / Setting-up assistance LEDs ⊗ P / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 50 / IP 65
Product certification
Dimensions (mm) H x W x D
CE - cULus
60 x 18 x 60
M L
Background suppression, 2 chnls.
50…600 mm
–
2 x Ø 4 holes, fixing ctrs. 54
Potentiometer
P / ⊗
0…+ 60 / IP 40
60 x 18 x 60
Sensors for DC applications
(solid-state output: transistor). Sensors with overload and short-circuit protection
Connection M8 connector
Transmitter / Receiver 3-wire PNP / NPN programmable NO / NC XUYPS1LCO965S
Supply voltage limits, min./max. (V) including ripple 10…30
Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 5000
XUYPS2CO945S
10…30
100 / 370
Accessories
PUR Pre-wired connectors (1)
M8 (4 pin)
Straight
Straight Elbowed
Elbowed
2 m XZCP0941L2 XZCP1041L2
5 m XZCP0941L5 XZCP1041L5
(1) For PVC cable see page 47
40
M12 (4 pin)
Straight
2 m XZCP1141L2
5 m XZCP1141L5
Elbowed
XZCP1241L2
XZCP1241L5
7/8" (5 pin)
Straight
2 m XZCP1764L2
5 m XZCP1764L5
Other versions: please consult our Customer Care Centre.
Photo-electric sensors with background suppression
Q
Application
System
Sensing distance
Fixing (mm) objects on conveyors
Q
Diffuse with adjustable background suppression
20…300 mm
Fixing : M3 holes,
Sensitivity adjustment
Case P (plastic) / Setting-up assistance LEDs ⊗ fixing centers 24 mm potentiomètre
P / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55 / IP67
0…1 m
Direct fixing centres
40 x 40, M4 screws
–
P / ⊗
- 25…+ 55 / IP 65
Product certification
Dimensions (mm) H x W x D
CE- cURus
33 x 20 x 11
CE - UL - CSA
50 x 18 x 50
Sensors for DC applications
(solid-state output: transistor). Sensors with overload and short-circuit protection
Connection
Transmitter / Receiver 3-wire PNP / NPN
PNP programmable NO / NC programmable NO / NC
Pre-cabled
–
Pre-cabled, PVC (2 m)
XUK8AKSNL2
–
Connection
NPN programmable NO / NC
XUM8APCNL2
XUM8ANCNL2
M8 connector
–
M12 connector
Transmitter / Receiver 3-wire PNP / NPN
PNP
NPN programmable NO / NC – programmable NO / NC programmable NO / NC
XUM8APCNM8 (1)
XUM8ANCNM8
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA) / Switching frequency (Hz)
XUK8AKSNM12
–
–
10…36
100 / 250
(1) also available with M12 remote connector with 0.3 m cable : replace M8 by L03M12.
2 m
Direct: fixing ctrs. 30/38 to 40/50/74 M5 screw
–
P / ⊗
- 25...+ 55 / IP 67
CE - UL - CSA
92 x 30,5 x 71
Screw terminals
XUX8AKSAT16 (3)
–
–
XUX8AKSAM12
–
–
10…36
100 / 150
Système
Sensing distance
Fixing (mm)
Diffuse with adjustable background suppression
70…120 mm
M18 x 1
10…750 mm
Direct fixing centres
Sensitivity adjustment
Case M (metal) P (plastic) / Setting-up assistance LEDs ⊗
Potentiometer
M / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) - 25…+ 55°C / IP 67
40 x 40, M4 screws teach mode
P / ⊗
- 25…+ 55°C / IP 65
Product certification
Dimensions (mm) Ø x L or H x W x D
CE - UL - CSA
M18 x 82
CE - UL - CSA
50 x 18 x 50
Multi-current/multi-voltage sensors for AC/DC applications
Connection
Transmitter / Receiver AC/DC NO function programmable NO / NC
Cable L = 2m
XU8M18MA230
–
Cable
–
XUK8ARCTL2
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA) / Switching frequency (Hz)
20…264
200 / 25
20…264
3000 / 20
Overload and short-circuit protection (g) / LED output state indicator (⊗) (2) / ⊗ –
(2) Sensor not short-circuit protected. Therefore, it is essential to connect a 0.4 A quick-blow fuse in series with the load.
2 m
Direct: fixing ctrs. 30/38 to 40/50/74 M5 screw
–
P / ⊗
- 25...+ 55 / IP 67
CE - UL - CSA
92 x 30,5 x 71
Screw terminals
–
XUX8ARCTT16
20…264
3000 / 20
–
Other versions: please consult our Customer Care Centre.
41
OsiSense XU Photo-electric sensors, fibre optic
Amplifier
Max. / usable sensing distance
Fixing (mm)
Sensitivity adjustment
Case P (plastic) / Setting-up assistance LEDs ⊗
+/- potentiometer
Depending on fibre used, plastic only
DIN rail or direct: fixing centres 25, M3 screws
+/- numeric potentiometer using teach mode
P / ⊗
Temperature range (°C) / Degree of protection (conforming to IEC 60529) 0…+ 60 / IP 65
Product certification CE - cULus
Dimensions (mm) L x H x W 60 x 30 x 13
Teach
P / ⊗
- 10…+ 55 / IP 65 (1)
CE - cULus - cURus
65 x 40 x 10
Teach + Timer Teach + Timer
+/- numeric potentiometer using teach mode
P / ⊗
0…+ 60 / IP 65
CE - cULus
60 x 30 x 13
P / ⊗ and 4-digit display
- 10…+ 55 / IP 65 (1)
CE - cULus - cURus
65 x 40 x 10
Sensors for DC applications
(solid-state output: transistor)
Connection
References
Amplifier
Connection
References
Amplifier
3-wire PNP programmable NO / NC
3-wire NPN programmable NO / NC
3-wire PNP programmable NO / NC
Pre-cabled, PVC (2 m)
–
–
M8 connector - 4 Pin
–
XUDA1PSML2
XUDA1NSML2
XUDA1PSMM8
3-wire NPN programmable NO / NC – XUDA1NSMM8
3-wire PNP/NPN programmable NO / NC XUYAFVCO966S (Glass) –
XUYAFPCO966S (Plastic) –
Supply voltage limits, min./max. (V) including ripple 10…30 10.8...26.4
–
–
XUDA2PSML2
XUDA2NSML2
– XUDA2PSMM8
– XUDA2NSMM8
XUYAFVCO946S (Glass) –
XUYAFPCO946S (Plastic) –
10…30 10.8...26.4
Switching capacity, max. (mA) / Switching frequency (Hz) 100 / 1000
Overload and short-circuit protection (g) / LED output state indicator (⊗) g / ⊗
(1) IP 65 with Ø 1 fibre/ IP 64 with Ø 0.5 fibre.
100 / 1000 g / ⊗
100 / 1000 time delayable 100 / 1000 time delayable g / ⊗ g / ⊗
Ecofibre system, assemble your own plastic fibres
Fibre Ø 1 mm
References
Length = 10 m
XUFZ910
Length = 20 m
XUFZ920
End fittings
Sensing distance (mm)
Type
Thread
Lens
References
Accessories
For thru-beam system plastic fibre optics
Lenses For increasing
sensing distance (pair) XUFZ01
70 200 800 1200 4000 1200 with threaded end with plain end fitting, with plain end fitting, with threaded end with threaded end 90° mirror, with fitting
M8 x 1, L = 10 mm yes
XUYA110
Ø 3, L = 9 mm
– no
XUYA210
Ø 3, L = 9 mm
– yes
XUYA211 fitting
M6 x 1, L = 10 mm yes
XUYA212 fitting threaded end fitting
M6 x 1, L = 10 mm M6 x 1, L = 3 to 10 mm yes
XUYA213 yes
XUYA220
For all system plastic fibre optics
Fibre trimmer For trimming fibres to length (included with all fibre optics) XUFZ11
Plug-in PUR pre-wired female connectors (1)
Cable length 5 m, without LED pre-wired, elbowed pre-wired, straight
With 90° mirror
(pair) XUFZ02
Fixing clamp with lens (set of 2)
Front screw fixing for fibre optics
XUFZ920 XUFZ04
Protective metal tubing
Length 1 m, for fibres with threaded end fittings
For M4 thread XUFZ210
For M6 thread XUFZ310
XZCP1041L5
(1) For PVC cable see page 47
XZCP0941L5
Other versions: please consult our Customer Care Centre.
42
Photo-electric sensors, fibre optic
Amplifier Plastic fibre optic light guides (length 2 m)
System
Sensing distance (mm)
Fibre cross-section
M4 / M2.6 (1)
Thru-beam
200 or 1500 (2)
M4 / L = 90 mm
180
Fibre Ø (mm)
Sheath Ø (mm)
Ø 1
Ø 2.2
Ø 1
Ø 2.2
Temperature range (°C)
References
Fixing
- 25...+ 60
XUFN12301
M4 x 0.7
(1) Can be used with 90° mirror XUFZ02 (see preceding page).
(2) With lens accessory XUFZ01 (see preceding page)
- 25...+ 60
XUFN12311
M4 x 0.7
M3 / M2.6 (1)
50 or 1000 (2)
Long range fibres with integrated lens
M8 / L = 20 mm
Long range fibres
M4 / M2.6 (1)
2500
Flexible fibres
M4 / M2.6 (1)
300 or 2000 (2) 100 or 750 (2)
Ø 0.5
Ø 1
- 25...+ 60
XUFN35301
M3 x 0.5
Ø 1
Ø 2.2
- 25...+ 60
XUFN2L01L2
M8 x 1.25
Ø 1.5
Ø 2.2
Ø 1
Ø 2.2
- 25...+ 60 - 25...+ 60
XUFN2P01L2 XUFN2S01L2
M2.6 x 0.45 / M4 x 0.7 M2.6 x 0.45 / M4 x 0.7
System
Sensing distance (mm)
Fibre cross-section
Fibre Ø (mm)
Sheath Ø (mm)
Temperature range (°C)
References
Fixing
M6
Diffuse
70
Ø 1
Ø 2.2 x 2
- 25...+ 60
XUFN05321
M6 x 0.75
M4 / M6
60
Ø 1+16 Ø 0.265
Ø 2.2 x 2
- 25...+ 60
XUFN05323
M6 x 0.75 / M4 x 0.7
M6/L = 90 mm
60
Ø 1
Ø 2.2 x 2
- 25...+ 60
XUFN05331
M6 x 0.75
M4 / M2.6
15
Ø 0.5 + 4 Ø 0.23
Ø 1 x 2
- 25...+ 60
XUFN02323
M4 x 0.7
System
Sensing distance (mm)
Fibre cross-section
Fibre Ø (mm)
Sheath Ø (mm)
Temperature range (°C)
References
Fixing
M4 / L = 90 mm
Diffuse
18
Ø 0.5
Ø 1 x 2
- 25...+ 60
XUFN01331
M4 x 0.7
M4 / M2.6
18
Long range fibres
M6 / L = 15 mm
95
Ø 0.5
Ø 1 x 2
- 25...+ 60
XUFN01321
M4 x 0.7
Ø 1.5
Ø 2.2 x 2
- 25...+ 60
XUFN5P01L2
M6 x 0.75
Glass fibre optic light guides (length 0.6 m)
System
Sensing distance (mm)
Fibre cross- section
M4
Thru-beam
200
M4 / Ø 2.5 x 89 M4
Diffuse
80
M4 / Ø 2.5 x 89
End fitting
Fibre Ø (mm)
Sheath Ø (mm)
Temperature range (°C)
References
Straight
1
2.2
Adaptable Straight
1
PVC sheath: - 25…+ 60 / Metal wound: - 25…+ 120 / Flexible stainless steel: - 25…+ 200
PVC sheath
Metal wound
XUYFVERSD61
XUYFVERMD61
Flexible stnl. steel XUYFVERTD61
–
XUYFVERSC61
–
2.2
XUYFVPSD61
XUYFVPMD61
XUYFVPTD61
Adaptable
XUYFVPSC61
XUYFVPMC61
XUYFVPTC61
M4
90°
XUYFVPSL61
XUYFVPML61
XUYFVPTL61
Other versions: please consult our Customer Care Centre.
43
OsiSense XX Ultrasonic sensors
Detection of any material
M12 M18 M18
Nominal sensing distance Sn
Operating zone for proximity mode
Mode proximity or reflex (1)
Mode thru beam
Sensitivity adjustment
Case M (metal), P (plastic)
Product certification
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Dimensions (mm) Ø x L
–
–
10...28
<100 g
⊗ / ⊗
<1
125
500
5 or 10 cm depending on model 15 or 50 cm depending on model 50 mm
20 cm
0.64…5.1 cm (XX512A1…)
61 or 100 cm depending on model
1.9…15.2 cm (XX518A1…) 2…50 mm
0.64…10.2 cm (XX512A2…)
Fixed
P
CE
- 20…+ 65
IP 67
M12 x 50
5.1…50.8 cm (XX518A3…)
Adjustable using remote control for XX518 A3. Fixed for XX518A1,
XXT18, XXR18
P
CE
0…+ 50 (XX518A1…) /
- 20…+ 65 (XX518A3…) / 0... 60
(XXT18, XXR18)
M18 x 65
Fixed
M
CE
0…+ 60
M18 x 75 (M12) M18 x 65 (Cable)
Proximity or Reflex
(1)
mode with “Discrete” output for DC applications
(24 V)
Connection
3-wire PNP NO function
M8 connector
XX512A2PAM8 (10 cm)
M12 connector
XX518A3PAM12 (50 cm)
NPN NO function
4-wire PNP/NPN
Application - monitoring levels
2 emptying levels
2 filling levels
NO function
PNP NO function
PNP NO function
Supply voltage limits, min./max. (V) including ripple
Switching capacity, max. (mA)
Short-circuit protection (g)
LED output state indicator (⊗) / Power on LED (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Transmission frequency (kHz)
(1) Reflex mode only for sensor with adjustable sensitivity.
(2) 1 NO
XX512A2NAM8 (10 cm)
XX512A1KAM8 (5 cm)
XX518A3NAM12 (50 cm)
XX518A1KAM12 (15 cm)
XX218A3PHM12 (50 cm) (2)
XX218A3PFM12 (50 cm) (2)
⊗ / ⊗ except XX518A1.. (- / -)
40 / 80 (XX518A1..)
300
–
–
Pre-cabled (2 m), M12 connector
XXV18B1PAL2 (cable)
XXV18B1PAM12 (M12)
XXV18B1NAL2 (cable)
XXV18B1NAM12 (M12)
–
Proximity mode with “Analogue” output for DC applications
(24 V)
Connection
4-wire Analogue 0…10 V output
4…20 mA output
Supply voltage limits, min./max. (V) including ripple
–
–
M12 connector
–
Short-circuit protection (g)
LED output state indicator (⊗) / Power on LED (⊗)
Transmission frequency (kHz)
–
–
–
Thru beam mode with “Discrete” output for DC applications
(24 V)
Connection
4-wire Receiver (NO/PNP + NO NPN)
M8 connector
XXR12A8KAM8
Receiver (NC/PNP + NC NPN)
Transmitter
XXR12A8KBM8
XXT12A8M8
XX918A3F1M12 (50 cm)
XX918A3C2M12 (50 cm)
10…28 g
⊗ / ⊗
300
M12 connector
XXR18A3KAM12 (0.61 m)
XXR18A4KAM12 (1 m)
XXR18A3KBM12 (0.61 m)
XXR18A4KBM12 (1 m)
XXT18A3M12 (0.61 m)
XXT18A4M12 (1 m)
–
–
–
–
–
–
–
–
–
Accessories
See page 45 for progamming and connectors, and page 46 for fixing
Other versions: please consult our Customer Care Centre.
44
Ultrasonic sensors
Detection of any material
Nominal sensing distance Sn
Operating zone for proximity mode
Sensitivity adjustment
Mode proximity or reflex (1)
Case M (metal), P (plastic)
Product certification
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Dimensions (mm) Ø x L
M30
1 m
0.1...1 m
Adjustable using remote control
P
CE
0…+ 70
IP 67
M30 x 78
1 m
0.05...0.99 m
Adjustable using teach mode
0…+ 70
IP 65
M30 x 85
2 m
0.12...2 m
M30
Long range
8 m
0.3...8 m
P
CE
- 20…+ 60
M30 x 106
Proximity or Reflex
(1)
mode with “Discrete” output for DC applications
(24 V)
Connection
3-wire
4-wire
PNP
NPN
PNP/NPN
PNP
NO function
NO function
NO function
NO + NC function
NPN
Application - monitoring levels
2 emptying levels
2 filling levels
NO + NC function
PNP NO function
PNP NO function
Supply voltage limits, min./max. (V) including ripple
–
–
M12 connector
XX6V3A1PAM12
XX6V3A1NAM12
–
–
–
10...28
–
–
XX630A1KAM12
XX630A1PCM12 (2)
XX630A1NCM12 (2)
–
–
–
–
–
XX230A10PA00M12 (3) XX230A20PA00M12 (3) –
XX230A11PA00M12 (3) XX230A21PA00M12 (3) –
–
–
M12 connector
–
XX630A3PCM12
XX630A3NCM12
<100 g
Switching capacity, max. (mA)
Short-circuit protection (g)
LED output state indicator (⊗) / Power on LED (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Transmission frequency (kHz)
(1) Reflex mode only for sensor with adjustable sensitivity.
⊗ / ⊗
<1
70
180
10
200
2
75
Proximity mode with “Analogue” output for DC applications
(24 V)
Connection
4-wire Analogue 0…10 V output
4…20 mA output
Supply voltage limits, min./max. (V) including ripple
M12 connector
XX9V3A1F1M12
XX9V3A1C2M12
10…28
XX930A1A1M12 (2)
XX930A1A2M12 (2)
10…28
–
–
–
XX930A3A1M12
XX930A3A2M12
10…28
Short-circuit protection (g)
LED output state indicator (⊗) / Power on LED (⊗) g
⊗ / ⊗ g
⊗ / ⊗
–
– g
⊗ / ⊗
Transmission frequency (kHz) 180 200 – 75
(2) Stainless steel 303 version also available. To order, replace the first letter A in the reference by S. Example: XX630A1PCM12 becomes XX630S1PCM12.
(3) 2 NO
Accessories
Programming
Remote control teach button for use with sensors XX●18A3●●●,
XX●V1●●●, XX●V3●●● and XX●D1
Suitable female plug-in connectors
PUR Pre-wired connectors (1) elbowed straight
Other connectors screw terminal
XXZPB100
For fixing see page 46
L = 5 m (without LED)
M8 for XX512A1…
M12 for XX512A2… for all sensors except XX512...
XZCP1041L5
XZCP0666L5
XZCP0941L5
XZCP0566L5
XZCP1241L5 XZCP1141L5
(1) For PVC cable see page 47
XZCC8FCM40V
XZCC8FCM30V
XZCC12FCM40B
Other versions: please consult our Customer Care Centre.
45
OsiSense XX Ultrasonic sensors
Detection of any material
Nominal sensing distance Sn
Operating zone for proximity mode
Mode proximity or reflex (1)
Mode thru beam
Sensitivity adjustment
Mini flat
10 cm
20 cm
0.62…10.2 cm
–
Fixed
Flat
25 cm
Combined multi-fixing
50 cm
61 or 100 cm depending on model
–
5.1…25.4 cm 5.1…50.8 cm
–
Fixed
P
CE
0…+ 50
–
Adjustable using remote control
P
CE
- 20…+ 65
Case P (plastic)
Product certification
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Dimensions (mm) Ø x L or H x W x D
P
CE
- 20…+ 65
IP 67
33 x 19 x 7.6
74 x 30 x 16
Proximity or Reflex
(1)
mode with “Discrete” output for DC applications
(24 V)
Connection
3-wire PNP
NPN
NO function
NO function
Supply voltage limits, min./max. (V) including ripple
M12 on 0.15 m flying lead M12 connector
XX7F1A2PAL01M12 XX7K1A2PAM12
XX7F1A2NAL01M12
10…28
XX7K1A2NAM12
<100 g
Switching capacity, max. (mA)
Short-circuit protection (g)
LED output state indicator (⊗) / Power on LED (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Transmission frequency (kHz)
(1) Reflex mode only for sensor with adjustable sensitivity.
⊗ / ⊗
<1
100
500
80
500
M 18 / 18 x 33 x 60
XX7V1A1PAM12
XX7V1A1NAM12
40
300
Proximity mode with “Analogue” output for DC applications
(24 V)
Connection
4-wire Analogue 0…10 V output
4…20 mA output
Supply voltage limits, min./max. (V) including ripple
–
–
–
–
Short-circuit protection (g)
LED output state indicator (⊗) / Power on LED (⊗)
–
–
–
–
–
–
–
Transmission frequency (kHz) – –
Thru beam mode with “Discrete” output for DC applications
(24 V)
Connection
4-wire Receiver (NO/PNP + NO/NPN)
–
XXRF1A8KAM12L
Receiver (NC/PNP + NC/NPN)
Transmitter
XXRF1A8KBM12L
XXTF1A8M12L
XXRK1A3KAM12 (0,61m)
XXRK1A4KAM12 (1m)
XXRK1A3KBM12 (0,61m)
XXRK1A4KBM12 (1m)
XXTK1A3M12 (0,61m)
XXTK1A4M12 (1m)
Accessories
Fixings - 3D fixings with ball joint
Bracket with ball joint for cylindrical sensors
M12 rod for ball joint
Fixing support for
M12 rod
–
–
–
Simple fixings
90° fixing brackets
M12 connector
XX9V1A1F1M12
XX9V1A1C2M12
10…28 g
⊗ / ⊗
300
–
–
–
Flat 80 x 80
1 m
–
0.1…1 m
–
Adjustable using remote control
P
CE
0...+ 70
80 x 80 x 34
XX8D1A1PAM12
XX8D1A1NAM12
70
180
XX9D1A1F1M12
XX9D1A1C2M12
10…28 g
⊗ / ⊗
180
Mounting plates for XX7K
3D kit example for
Ø 12 XUZB2012
Ø 18 XUZB2003
Ø 30 XUZB2030
See page 45 for progamming and connectors
46
XUZ2001 XUZ2003 for
Ø 12
Ø 18
Ø 30
XX7F
XXZ12
XUZA118
XXZ30
XXZ1933 flat cranked
XXZ3074F
XXZ3074S
Other versions: please consult our Customer Care Centre.
Nominal sensing distance Sn
Operating zone for proximity mode
Mode proximity or reflex (1)
Mode thru beam
Sensitivity adjustment
Mini flat
10 cm
20 cm
0.62…10.2 cm
–
Fixed
Flat
25 cm
Combined multi-fixing
50 cm
61 or 100 cm depending on model
–
5.1…25.4 cm 5.1…50.8 cm
–
Fixed
P
CE
0…+ 50
–
Adjustable using remote control
P
CE
- 20…+ 65
Case P (plastic)
Product certification
Temperature range (°C)
Degree of protection (conforming to IEC 60529)
Dimensions (mm) Ø x L or H x W x D
P
CE
- 20…+ 65
IP 67
33 x 19 x 7.6
74 x 30 x 16
Proximity or Reflex
(1)
mode with “Discrete” output for DC applications
(24 V)
Connection
3-wire PNP
NPN
NO function
NO function
Supply voltage limits, min./max. (V) including ripple
M12 on 0.15 m flying lead M12 connector
XX7F1A2PAL01M12 XX7K1A2PAM12
XX7F1A2NAL01M12
10…28
XX7K1A2NAM12
<100 g
Switching capacity, max. (mA)
Short-circuit protection (g)
LED output state indicator (⊗) / Power on LED (⊗)
Voltage drop, closed state (V) at I nominal
Switching frequency (Hz)
Transmission frequency (kHz)
(1) Reflex mode only for sensor with adjustable sensitivity.
⊗ / ⊗
<1
100
500
80
500
M 18 / 18 x 33 x 60
XX7V1A1PAM12
XX7V1A1NAM12
40
300
Proximity mode with “Analogue” output for DC applications
(24 V)
Connection
4-wire Analogue 0…10 V output
4…20 mA output
Supply voltage limits, min./max. (V) including ripple
–
–
–
–
Short-circuit protection (g)
LED output state indicator (⊗) / Power on LED (⊗)
–
–
–
–
–
–
–
Transmission frequency (kHz) – –
Thru beam mode with “Discrete” output for DC applications
(24 V)
Connection
4-wire Receiver (NO/PNP + NO/NPN)
–
XXRF1A8KAM12L
Receiver (NC/PNP + NC/NPN)
Transmitter
XXRF1A8KBM12L
XXTF1A8M12L
XXRK1A3KAM12 (0,61m)
XXRK1A4KAM12 (1m)
XXRK1A3KBM12 (0,61m)
XXRK1A4KBM12 (1m)
XXTK1A3M12 (0,61m)
XXTK1A4M12 (1m)
Accessories
Fixings - 3D fixings with ball joint
Bracket with ball joint for cylindrical sensors
M12 rod for ball joint
Fixing support for
M12 rod
–
–
–
Simple fixings
90° fixing brackets
M12 connector
XX9V1A1F1M12
XX9V1A1C2M12
10…28 g
⊗ / ⊗
300
–
–
–
Flat 80 x 80
1 m
–
0.1…1 m
–
Adjustable using remote control
P
CE
0...+ 70
80 x 80 x 34
XX8D1A1PAM12
XX8D1A1NAM12
70
180
XX9D1A1F1M12
XX9D1A1C2M12
10…28 g
⊗ / ⊗
180
Mounting plates for XX7K
3D kit example for
Ø 12 XUZB2012
Ø 18 XUZB2003
Ø 30 XUZB2030
See page 45 for progamming and connectors
XUZ2001 XUZ2003 for
Ø 12
Ø 18
Ø 30
XX7F
XXZ12
XUZA118
XXZ30
XXZ1933 flat cranked
XXZ3074F
XXZ3074S
OsiSense XZ
PVC cable
M8 and M12 connector
PVC cable
1/2" and 7/8" connector
PUR cable halogen free
M8, M12,1/2" and 7/8" connector
Connector Size
Reinforced PVC cable, stainless steel ring
M8, M12,1/2" and 7/8" connector
References PVC cable
PUR cable
PVC cable IP69K
Cabling system
Pre-wired female connectors
M8
Straight 3 pin
XZCPV0566Lp
XZCP0566Lp
XZCPA0566Lp
Elbowed 3 pin
XZCPV0666Lp
XZCP0666Lp
–
Straight 4 pin
XZCPV0941Lp
XZCP0941Lp
XZCPA0941Lp
Elbowed 4 pin
XZCPV1041Lp
XZCP1041Lp
–
Connector Size
References
Other accessories
References
PVC cable
PUR cable
PVC cable IP69K
M12
Straight 4 pin
XZCPV1141Lp
XZCP1141Lp
XZCPA1141Lp
Elbowed 4 pin
XZCPV1241Lp
XZCP1241Lp
XZCPA1241Lp
Straight 5 pin
XZCPV1164Lp
XZCP1164Lp
XZCPA1164Lp
Elbowed 5 pin
XZCPV1264Lp
XZCP1264Lp
–
Connector Size
References PVC cable
PUR cable
PVC cable IP69K
1/2"
Straight 3 pin
XZCPV1865Lp
XZCP1865Lp
XZCPA1865Lp
Complete each reference by adding the length of cable, as 2 for 2 m, 5 for 5 m and 10 for 10 m
Eg: XZCPV1141L 2 is pre-wired connector M12 connectors with 4 contacts and 2 m PVC cable
Elbowed 3 pin
XZCPV1965Lp
XZCP1965Lp
XZCPA1965Lp
7/8"
Straight 3 pin
XZCPV1670Lp
XZCP1670Lp
–
Straight 5 pin
–
XZCP1764Lp
–
Jumpers
XZCR...
Connector
XZCC...
Receptacle
XZCE...
Other versions: please consult our Customer Care Centre.
47
OsiSense XCC Opto-electronic rotary encoders
Incremental
(6)
Diameter of housing (mm)
Shaft Ø (mm)
Type of shaft (2)
Maximum rotational speed (rpm)
Maximum frequency (kHz)
Maximum load (daN)
Ø 40
Ø 6 solid shaft
9000
100
2
Ø 40
Ø 6 through shaft
9000
100
2
Torque (N.cm)
Product certification
Supply voltage 5 V, RS 422
Push-pull
0.2
CE
Temperature range (°C) - 20…+ 80
Degree of protection (conforming to IEC 60529) IP 54
4.5…5.5 V
11…30 V
4.5…5.5 V
11…30 V
Pre-cabled (2 m), radial Connection
Resolution (Points) Output stage
100 5 V, RS 422
Push-pull
0.25
CE
- 20…+ 80
IP 52
360
500
1000
1024
2500
3600
256…4096
5000
360…5760
500…8000
10 000
1024…16 384
5000…80 000
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Push-pull
5 V, RS 422
Ø 58
Ø 6 solid shaft
9000
300
10
0.4
CE
- 30…+ 100
IP 65 / IP 67 (3)
4.75…30 V
5…30 V
Ø 58
Ø 10 solid shaft
9000
300
10
0.4
CE
- 30…+ 100
IP 65 / IP 67 (3)
4.75…30 V
5…30 V
M23 male connector, radial
Ø 58
Stainless steel 316L Parametrable
25
IP69K
Ø 14 (1) through shaft
6000
300
5
0.6
CE
- 30…+ 70
IP 65
4.75…30 V
5…30 V
Ø 90
Ø 12 solid shaft
6000
100
20
1
CE
- 20…+ 80
IP 66
4.5…5.5 V
11…30 V
Pre-cabled (2 m), axial M23 male connector, radial
–
–
–
–
–
–
–
–
–
–
–
–
XCC1406PR01R XCC1406TR01R XCC1506PS01X XCC1510PS01X –
XCC1406PR01K XCC1406TR01K XCC1506PS01Y XCC1510PS01Y –
XCC1406PR03R XCC1406TR03R XCC1506PS03X XCC1510PS03X – –
XCC1406PR03K XCC1406TR03K XCC1506PS03Y XCC1510PS03Y XCC1510SPA03Y –
–
–
XCC1406PR05R XCC1406TR05R XCC1506PS05X XCC1510PS05X –
XCC1406PR05K XCC1406TR05K XCC1506PS05Y XCC1510PS05Y –
XCC1406PR10R XCC1406TR10R XCC1506PS10X XCC1510PS10X –
XCC1406PR10K XCC1406TR10K XCC1506PS10Y XCC1510PS10Y –
–
–
–
–
XCC1912PS01RN
XCC1912PS01KN
XCC1912PS03RN
XCC1912PS03KN
XCC1912PS05RN
XCC1912PS05KN
XCC1912PS10RN
XCC1912PS10KN
–
–
–
–
–
–
XCC1406PR11R XCC1406TR11R XCC1506PS11X XCC1510PS11X – –
XCC1406PR11K XCC1406TR11K XCC1506PS11Y XCC1510PS11Y XCC1501SPA11Y –
–
–
XCC1506PS25X XCC1510PS25X –
XCC1506PS25Y XCC1510PS25Y –
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XCC1912PS11RN
XCC1912PS11KN
XCC1912PS25RN
XCC1912PS25KN
–
–
XCC1514TSM02X –
XCC1514TSM02Y –
XCC1912PS36RN
XCC1912PS36KN
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XCC1506PS50X XCC1510PS50X – –
XCC1506PS50Y XCC1510PS50Y XCC1510SPA50Y –
–
–
–
–
XCC1514TSM03X –
XCC1514TSM03Y –
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
XCC1514TSM05X –
XCC1514TSM05Y –
–
–
XCC1912PS00RN
XCC1912PS00KN
XCC1514TSM11X –
XCC1514TSM11Y –
XCC1514TSM50X –
XCC1514TSM50Y –
XCC1912PS50RN
XCC1912PS50KN
Accessories
Shaft couplings with spring
Push-pull
Bore diameter
(encoder side)
6 mm
6 mm
6 mm
10 mm
10 mm
Bore diameter
(machine side)
6 mm
8 mm
10 mm
10 mm
12 mm
Reference
XCCRAR0606
XCCRAR0608
XCCRAR0610
XCCRAR1010
XCCRAR1012
Fixing brackets
Plain bracket
Bracket with play compensator for Ø 58 mm for Ø 90 mm for Ø 58 mm for Ø 90 mm
XCCRE5SN
XCCRE9SN
XCCRE5RN
XCCRE9RN elastic 6 mm 6 mm XCCRAE0606
Other versions: please consult our Customer Care Centre.
48
Absolute
- single turn
(6)
Absolute
- multiturn
(6)
Communicating multiturn absolute
Diameter of housing (mm) Ø 58 Ø 90
Shaft Ø (mm)
Type of shaft (2)
Maximum rotational speed (rpm)
Maximum frequency (kHz)
Maximum load (daN)
Ø 10 solid shaft
9000
100
10 / 25 (6)
Ø 12 solid shaft
6000
100 (1000 SSI)
20
Torque (N.cm)
Product certification
0.4
CE
Temperature range (°C) - 20…+ 90 - 20…+ 85
Degree of protection (conforming to IEC 60529) IP 65 / IP 67 (3) / IP69K (6) IP 66
Supply voltage 11…30 V
1
CE
Ø 58 Ø 90
Ø 10 solid shaft
6000
100 (500 SSI)
10
Ø 12 solid shaft
6000
100 (500 SSI)
20
0.4
CE
1
CE
- 20…+ 85 - 20…+ 85
IP 65 / IP 67 (3) / IP69K (6) IP 66
Ø 58
CANopen
Ø 10
solid shaft (4)
6000
800
11
0.3
CE
- 40…+ 85
IP 64
Ø 58
PROFIBUS-DP
Ø 10
solid shaft (4)
6000
800
11
0.3
CE
- 40…+ 85
IP 64
Connection
Resolution Output stage
… 8192 points Push-pull
4096 points /
8192 turns
8192 points /
4096 turns
SSI, 13 bits
SSI, 25 bits (5)
SSI, 25 bits (5)
Code
Binaire
Gray
Binaire
Gray
Gray
Binaire
Gray
M23 male connector, radial / 2m Axial cable (6) 2 x M12 + 1 x Pg 9 3 x Pg 9
XCC2510PS81KB XCC2912PS81KBN –
XCC2510PS81KGN XCC2912PS81KGN –
XCC2510SPA81KGN (6)
XCC2510PS81SBN XCC2912PS81SBN –
XCC2510PS81SGN
XCC2510SPA81SGN (6)
XCC2912PS81SGN –
– –
–
–
–
–
–
–
–
–
–
–
–
–
XCC3510PS48SGN
XCC3510SPA48SGN (6)
– –
XCC3510PS84SBN XCC3912PS84SBN –
XCC3510PS84SGN XCC3912PS84SGN –
– –
–
–
–
–
–
–
–
8192 points / CANopen, Binaire –
4096 turns 25 bits
PROFIBUS-DP, Binaire
–
–
–
–
–
–
–
–
XCC3510PS84CBN –
– XCC3510PV84FBN
25 bits
(1) Anti-rotation device included with through shaft version encoders. To achieve Ø 6, 8, 10 or 12 mm through shafts, use the reduction collars.
(2) All versions are also available with through shaft and anti-rotation device.
(3) IP 67 with sealed collar XCCRB3.
(4) Versions available with hollow shaft and anti-rotation device.
(5) “Parallel” outputs possible for multiturn absolute encoders using derserialisation jumper cables XCCRM23SUB37●●.
(6) product in Stainless steel 316L
Reduction collars
For Ø 58 mm incremental encoders with through shaft
Ø 14 to Ø 6 mm XCCR158RDA06
Ø 14 to Ø 8 mm
Ø 14 to Ø 10 mm
Ø 14 to Ø 12 mm
XCCR158RDA08
XCCR158RDA10
XCCR158RDA12
IP 67 sealed collar
For encoders XCC1510, 2510, 3510
Ø 58 mm XCCRB3
Pre-wired connectors and jumper cables
Pre-wired M23 female connectors (cable length 5 m)
8-wire for SSI encoders
10-wire for incremental encoders
16-wire for parallel single turn absolute encoders
Deserialisation jumper cables (M23 F - SUB-D37 M) (L = 0.5 m)
SSI Gray - // Gray PNP
SSI binary - // binary NPN
XCCPM23122L5
XCCPM23121L5
XCCPM23161L5
XCCRM23SUB37PG
XCCRM23SUB37PB
Other versions: please consult our Customer Care Centre.
49
OsiSense XG Radio frequency identification
13.56 MHz RFID
Presentation
OsiSense XG is open to the majority of ISO 18000-3, ISO 15693 and ISO 14443 electronic tags.
OsiSense XG integrates Modbus RTU, Uni-Telway, Modbus TCP/IP (using Ethernet box XGSZ33ETH) and
Profibus DP (with box XGSZ33PDP) protocols.
The OsiSense XG RFID offer comprises:
- 3 models of 13.56 MHz smart antenna (read/write)
- 12 models of 13.56 MHz electronic tags
- 1 portable RFID diagnostics terminal
- 3 models of network connection boxes plus connection and mounting accessories.
Setting-up
OsiSense XG smart antenna are simple to set-up:
- Integrated RFID and network functions
- No programming
- Automatic detection of the RFID electronic tags (read or write)
- Automatic setting of the communication parameters (speed, format, parity, protocol, etc.)
- Configuration of the network address (1 to 15) using badge included with the smart antenna
- Low sensitivity to metal environments.
Installation
OsiSense XG smart antenna easily integrate in flexible manufacturing production lines:
- quick connection using M12 connector
- screw fixing or clip-on mounting.
Smart antenna, 13.56 MHz
Dimensions (mm), W x H x D
Nominal sensing distance depending on tag (mm)
Type of associated tag
Display
Conformity to standards
Degree of protection conforming to IEC 60529
Serial link Type
Protocol
Speed (Bauds)
Ambient air temperature (°C)
Nominal supply voltage
Connection
References
Flat form 40 Flat form 80
40 x 40 x 15
18 to 70
80 x 80 x 26
20 to 100
ISO 15693 and ISO 14443 standard tags. Automatic detection of the type of tag.
dual colour LED for the communication network, dual colour LED for the RFID communication
CE, EN 301489-1, EN 301489-3, ETS 300330-1 and ETS 300330-2, FCC part 15 - UL
IP 67
RS 485
Modbus and Uni-Telway
Ethernet (dual port)
MODBUS TCP/IP and EtherNet/IP
10/100MB 9600…115 200 (automatic detection)
For operation: - 25…+ 70 °C, for storage: - 40…+ 85 °C
24 VDC PELV (Protective Extra Low Voltage)
M12, 5-pin male, shielded connector on flying lead.
Only for connection to the communication network and the supply
XGCS4901201 XGCS8901201
M12 (Ethernet) -
M8 4pin (Power supply)
XGCS850C201
Electronic tags
Dimensions (mm), W x H x D
Type of memory
Memory capacity (bytes)
Nominal sensing distance (mm) With station XGCS49●
(Read/Write)
Time (ms)
With station XGCS89●
Read
Write
Degree of protection conforming to IEC 60529
Standard supported
Mounting on metal support
References
(1) Customised versions on request. (2) n = number of 16-bit words.
50
Flat form 40 ISO badge
(1)
Disc Flat form 26 Cylindrical
40 x 40 x 15
EEPROM
3 408
33
48
FRAM
32 768
25
39
54 x 85.5 x 0.8
EEPROM
256
70
100
9.25 + 0.375 x n (2) 6 + 0.25 x n (2) 12 + 0.825 x n (2)
Ø 30 x 3
112
48
65
26 x 26 x 13
256
40
55
M18 x 1 x 12
256
18
20
13 + 0.8 x n (2) 6 + 0.25 x n (2) 20 + 11.8 x n (2) 12 + 5.6 x n (2) 20 + 11.8 x n (2) 19 + 4.1 x n (2)
IP 68 IP 65 IP 68
ISO 14443
Yes
ISO 15693
No Yes No
XGHB444345 XGHB443245 XGHB90E340 XGHB320345 XGHB221346 XGHB211345
Other versions: please consult our Customer Care Centre.
Connection boxes
Dimensions (mm), W x H x D
Protocols
Supply voltage
Conformity to standards
Station connection
Degree of protection conforming to IEC 60529
References
Ethernet Modbus TCP/IP box Profibus box
130 x 80 x 51
Modbus TCP/IP Profibus DP
24 VDC PELV. M12, 4-pin male, A coding, connector
CE - UL CE
M12, 5-pin female, A coding, connector
IP 65
XGSZ33ETH XGSZ33PDP
EtherNet/IP box
130 x 80 x 51
EtherNet/IP
CE
XGSZ33EIP
Terminal
Dimensions (mm), W x H x P
Function
Operating system
Conformity to standards
Display
Degree of protection conforming to IEC 60529
Memory RAM
Storage
Reference
Portable 13.56 MHz RFID diagnostics terminal
78 x 153 x 27
Read/Write operations on electronic tags
Proprietary OS
CE, FCC class A, Part 15
53 x 95 mm colour OLED touchscreen 272 x 480 pixels resolution
IP 40
256 Mb internal 2 GB + USB socket for memory stick
XGST2422 (battery, battery charger, 2 GB USB memory stick, and carrying case included with terminal).
RFID reader to be ordered separately: XGCS4901201 (integrated reader) or XGW4F111 (remote reader)
Connection accessories for Modbus network
Description Modbus connecting Pre-wired connector
Application
L = 2 m
L = 5 m cable M12 connectors Male / Female
RS485 connection between a smart antenna and a connection box or between 2 Modbus boxes
TCSMCN1M1F2
TCSMCN1M1F5
M12 male / Bare wires
Connection between a Modbus box and a
Modbus / Uni-Telway network
TCSMCN1F2
TCSMCN1F5
Modbus connecting cable M12 female /
Mini-DIN 8
Connection between a Modbus box and a PLC
TCSMCN1F9M2P
–
(3) L = 3 m (4) L=10 m
Field expander
To be associated with a smart antenna XGCS4901201 for conveying and handling applications for Profibus
Profibus connecting cables M12 connectors Male / Female
Connection between
Profibus box and
Profibus network
FTXDP1220
FTXDP1250 for Ethernet
Ethernet connecting cable
M12 male / RJ 45
Connection between an Ethernet box and the Ethernet network
XGSZ12E4503 (3)
XGSZ12E4510 (4)
RS232/RS485 converter
For connecting a PC to an OsiSense XG smart antenna
Pre-wired connector “T” connector
Pre-wired supply connector
M12 female
24 VDC supply to connection boxes
XGSZ09L2
XGSZ09L5
Network M12
“T” connector
1 male / 2 female
For chaining of smart antennas on RS485 network
TCSCTN011M11F
Technical documentation
OsiSense XG smart antenna guide
50 x 400 mm
XGFEC540
250 x 250 mm
XGFEC2525 XGSZ24 DIA4ED3051001
Other versions: please consult our Customer Care Centre.
51
Preventa, the safety attitude around your machine life cycle
The Preventa range enhances safety throughout a machine’s entire life cycle from design, manufacture, installation, adjustment, operation and servicing right through to decommissioning.
In addition to moral obligation and economic consequences, the law requires that machinery is safe in the interests of accident prevention. Preventa offers an extensive range of safety products, compliant with international standards, designed to provide the most comprehensive protection for personnel and equipment.
Risk assesment analysis
Mainten nance /
Inspection
& Audit
Your machine
Conception
& Design
Implementation &
Certification
•
New machines - the Machinery Directive
The previous Machinery Directive 98/37/EC was elaborated to help manufacturers ensuring a minimum safety level for machinery and equipment sold within the EU (European Union).
From 29 December 2009 on, the new European Machinery Directive 2006/42/EC is effective. Machines must comply with the Essential Health and Safety Requirements (EHSRs) listed in Annex I of the Directive, thus setting a common minimum level of protection across the EEA (European Economic Area).
52
Machine manufacturers, or their authorised representatives within the EU, must ensure that the machine is compliant with all requirements from this Directive. This technical file is available to reinforce authorities requests as well as the CE marking must be affixed and a Declaration of Conformity has been signed before the machine may be placed on the market within the EU.
Other versions: please consult our Customer Care Centre.
Functional safety
•
Safety integrity level (SIL), Performance level (PL)
MACHINES
SAFETY OF SYSTEMS AND EQUIPMENT
EN/IEC 61508
Functional safety of electrical / electronic / programmable electronic safety-related systems
EN/ISO 13849-1
Safety related parts of control systems
EN/IEC 62061
Machine safety
Functional safety of control electrical / electronic / programmable electronic safety-related systems
Risk reduction according to EN/IEC 61508 and EN/ISO 13849-1
• Safety is achieved by risk reduction (for those hazards that cannot be designed-out).
• Residual risk is the risk remaining after protective measures have been taken.
• Protective measures realised by E/E/PE* safety related systems contribute to risk reduction.
* Electric / Electronic / Programmable electronic
RESIDUAL
RISK
TOLERABLE
RISK
EQUIPMENT UNDER
CONTROL RISK
Necessary risk reduction
Actual risk reduction
Practical risk covered by other technology safety-related systems
Practical risk covered by electrical / electronic / programmable electronic safety-related systems
Risk reduction achieved by all safety-related systems and external risk reduction facilities
Practical risk covered by external risk reduction facilities
Other versions: please consult our Customer Care Centre.
53
Functional safety of machinery
•
Approach according to EN/IEC 62061
Risk estimation for SIL assignment
Risk related to the identified hazard
Severity of the possible harm
Frequency and duration of exposure
Probability of occurrence of a hazardous event
Probability of avoiding or limiting harm
Fr
Pr
Av
Probability of occurrence of that harm
54
Example of SIL assignment
This assignment should be carried by determining the risk parameters that are shown below in an example.
Consequences
Irreversible: death, losing an eye or arm
Irreversible: broken limb(s), losing a finger(s)
Reversible: requiring attention from a medical practitioner
Reversible: requiring first aid
Severity (Se)
4
3
2
1
Frequency and duration of exposure (Fr)
Frequency of exposure > 10 min
1 h
> 1 h to 1 day
5
5
> 1 day to 2 weeks
> 2 weeks to 1 year
> 1 year
4
3
2
Probability of occurrence
Very high
Likely
Possible
Rarely
Negligible
Probability (Pr)
5
4
3
2
1
Probability of avoiding or limiting harm (Av)
Impossible
Rarely
Probable 1
5
3
Serial no.
1
2
Hazard
Hazard X
Se
4
Fr
5 +
Pr
4 +
Av
3 =
CI
12
Consequences
Death, losing an eye or arm
Permanent, losing fingers
Reversible, medical attention
Reversible, first aid
(Se)
4
3
2
1
3-4
SIL 2
Class CI
5-7
SIL 2
OM
8-10 11-13 14-15
SIL 2 SIL 3 SIL 3
SIL 1
OM
SIL 2
SIL 1
OM
SIL 3
SIL 2
SIL 1
Frequency and duration
Fr
<= 1 hour
> 1 h to <= 1 day
> 1 day to <= 2 wks
2 wks to <= 1 year
> 1 year
4
3
2
5
5
Probability of hzd. Event
Pr
Common
Likely
Possible
Rarely
Negligible
3
2
1
5
4
Avoidance
Av
Impossible
Possible
Likely
In this example the SIL 3 must be achieved by the safety-related control function intended to reduce the risk related to the identified hazard.
Determination of the SIL level achieved by the Safety-related control function (SRCF)
According to standard EN/IEC 62061 for each safety related control function, the SIL level is linked to:
• a target failure value for the probability of dangerous failure by hour of the SRCF: PFHD
• architectural constraints (hardware fault tolerance, diagnosis)
• a set of requirements related to the lifecycle of the safety related electrical control system
3
2
1
Safety integrity level
(SIL)
Probability of a dangerous
Failure per Hour
PFHD
>10 -8 to <10 -7
>10 -7 to <10 -6
>10 -6 to <10 -5
λ
λ s dd
λ du
λ d
= rate of safe failures,
= rate of detected dangerous failures,
= rate of undetected dangerous failures
= λ dd
+ λ du
In practice, detected dangerous failure are dealt with by fault
• The rate of failures λ can be expressed as follows: λ= λ s
• The calculation of the PFHD for a system
+ λ dd
+ λ du or subsystem depends on several parameters: the dangerous failure rate ( λ d
) of the subsystem elements
the fault tolerance (e.g. redundancy) of the system
the diagnostic test interval (T2)
the proof test interval (T1) or lifetime whichever is smaller
the susceptibility to common cause failures ( β)
• For each of the four different logical architectures A to D there is a different formula to calculate the PFHD. (see EN/IEC 62061)
• For a simple system without redundancy and without diagnostic:
PFHD = λ d
x 1/h
5
3
1
Other versions: please consult our Customer Care Centre.
•
Approach according to EN/ISO 13849-1
Determination of the Performance Level requested
(PLr)
Done using the risk graphic opposite
S = Severity of injury
S1 = Slight (normally reversible injury)
S2 = Serious (normally irreversible) injury including death
F = Frequency and/or exposure time to the hazard
F1 = Seldom to less often and/or the exposure time is short
F2 = Frequent to continuous and/or the exposure time is long
P = Possibility of avoiding the hazard or limiting the harm
P1 = Possible under specific conditions
P2 = Scarcely possible
L = Low contribution to risk reduction
H = High contribution to risk reduction
Determination of the PL achieved by the
Safety-related parts of control systems (SRP/CS)
According to standard EN/ISO 13849-1, the Performance level (PL) is linked to a target failure value of probability of dangerous failure per hour for each safety related control function.
Starting point for the evaluation of the contribution to the risk reduction of a safety function
Required performance level PLr c d a b e
Performance level (PL)
Probability of a dangerous
Failure per Hour
≥ 10 -5 ... < 10 -4
≥ 3 x 10 -6 ... <10 -5
≥ 10 -6 …< 3 x 10 -6
≥ 10 -7 …< 10 -6
≥ 10 -8 …< 10 -7
For a SRP/CS (or a combination of
SRP/CS) designed according the requirements of the article 6, the PL could be estimated with the figure beside after estimation of several factors such as system structure
(categories), mechanism of failures detection [Diagnosis Coverage (DC)], components reliability [mean time to dangerous failure (MTTFd), Common
Cause Failure (CCF)]…
MTTF d
of each channel = low
MTTF d
of each channel = medium
MTTF d
of each channel = high
Cat. B
DC avg
0
=
Cat. 1
DC
0 avg
=
Cat. 2
DC avg low
=
Cat. 2
DC avg
= medium
Cat. 3
DC low avg
=
Safety category level according to EN/ISO 13849-1
Cat. 3
DC avg
= medium
Cat. 4
DC avg high
=
Other versions: please consult our Customer Care Centre.
55
Preventa
Detection
Safety switches and actuators
ISO entry
(to EN 50262)
Illustration of contacts with the actuator inserted in the head of the switch
2-pole contact
Slow break
(1NC+1NO)
3-pole contact
Slow break
(1NC+2NO)
40,3
20/22
20/22
20/22
2-pole contact
Slow break
(2NC)
3-pole contact
Slow break
(2NC+1NO)
Plastic, double insulated switches
Without locking
Type XCSMP Type XCSPA Type XCSTA
Maximum safety level (3)
Actuation speed (min --> max)
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
0,05m/s --> 1,5m/s 0,1m/s --> 0,5m/s
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15, C 300 / DC 13, Q 300
Degree of protection conforming to IEC 60529 IP67
Reliability data B
10d
Body + Head dimensions (mm) W x D x H
5 000 000 value given for a service life of 20 years, limited by mechanical or contact wear
30 x 15 x 87 mm 30 x 30 x 93,5 mm
0,1m/s --> 0,5m/s
52 x 30 x 114,5 mm
10 N (1) Resistence to forcible withdrawal of actuator
Wiring connection
Safety contacts 1NC+1NO break before make, slow break
2NC slow break
8 N pre-cabled, L = 2m
XCSMP59L2
XCSMP79L2
10 N (1)
1 x ISO M16 entry.
XCSPA592
XCSPA792
1 x PG11 entry
XCSPA591
XCSPA791
1NC+2NO break before make, slow break – XCSPA892 XCSPA891
2NC+1NO break before make, slow break
2NC+1NO snap action
XCSMP70L2
–
XCSPA992
XCSPA492
XCSPA991
XCSPA491
3NC slow break XCSMP80L2 –
(1) In order to increase the resistance to 50 N, you must add the accessory XCSZ21 to the key actuators XCSZ12
–
(2) With entry for n° 11 (Pg 11) cable gland, replace the last digit in the reference by 1 (example: XCSTA592 becomes XCSTA591).
2 x ISO M16 entries. (2)
–
–
XCSTA592
XCSTA792
–
XCSTA892
ISO entry
(to EN 50262) 3-pole contact
Slow break
(1NC+2NO)
30
3-pole contact
Slow break
(2NC+1NO)
Illustration of contacts with the actuator inserted in the head of the switch
Metal, double insulated switches
Without locking
Type XCSA
With interlocking, manual unlocking
By button By key lock
Type XCSB Type XCSC
Maximum safety level (3)
Actuation speed (min --> max)
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
0,01m/s --> 0,5m/s
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15, A 300 / DC 13, Q 300
Degree of protection conforming to IEC 60529 IP67
Reliability data B
10d
Body + Head dimensions (mm) W x D x H
5 000 000 value given for a service life of 20 years, limited by mechanical or contact wear
40 x 44 x 113.5 mm
0,01m/s --> 0,5m/s
52 x 44 x 113.5 mm
20 N 1500 N Resistence to forcible withdrawal of actuator
Wiring connection
Safety contacts 1NC+2NO break before make, slow break
2NC+1NO break before make, slow break
3NC slow break
(3) Using an appropriate and correctly connected control system.
1 x ISO M20 entry
XCSA502
XCSA702
XCSA802
1 x PG13,5 entry
XCSA501
XCSA701
XCSA801
1 x ISO M20
XCSB502
XCSB702
–
1 x PG13,5 entry
XCSC501
XCSC701
XCSC801
Accessoires
For safety switches XCSMP
References
Straight actuator
Actuators
XCSZ81
Right-angled actuator Pivoting actuator, RH door Pivoting actuator, LH door
XCSZ84 XCSZ83 XCSZ85
For safety switches XCSPA/TA
References
(4) For L = 29 mm, reference = XCSZ15.
56
Straight actuator Wide actuator L=40 mm (4) Right-angled actuator Pivoting actuator
Actuators
XCSZ11 XCSZ12 XCSZ14 XCSZ13
Guard/door retainer
Retaining device
XCSZ21
Other versions: please consult our Customer Care Centre.
Illustration of contacts with the actuator inserted in the head of the switch
2-pole contact
Slow break
(1NC+1NO)
ISO entry
(to EN 50262)
3-pole contact
Slow break
(1NC+2NO)
30
30
2-pole contact
Slow break
(2NC)
3-pole contact
Slow break
(2NC+1NO)
Safety interlock switches
Standard version and Connector version
Maximum safety level (3)
Degree of protection conforming to IEC 60529
Reliability data B10d
Body + Head dimensions (mm) W x D x H
Resistence to forcible withdrawal of actuator
Locking
Power supply for the solenoid and the LEDs
Material case
Wiring connection (2)
Safety contacts 1NC+1NO (break before make, slow break)
2NC (simultaneous, slow break)
1NC+2NO (break before make, slow break)
2NC+1NO (break before make, slow break)
3NC (simultaneous, slow break)
Type XCSLF, metal Type XCSLE, plastic
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
IP66 and IP67 IP65 IP66 and IP67 IP65
5 500 000 value given for a service life of 20 years, limited by mechanical or contact wear
43,5 x 51 x 205 mm 43,5 x 51 x 205 mm
3 000 N on de-energization (1)
24VAC/DC
Zamak
3 x ISO M20
1 400 N on de-energization (1)
XCSLF2525312
XCSLF2727312
XCSLF3535312
XCSLF3737312
XCSLF3838312
Connector M23 (4)
XCSLF252531M2
XCSLF272731M2
XCSLF353531M3
XCSLF373731M3
XCSLF383831M3
Polyamide
3 x ISO M20
XCSLE2525312
XCSLE2727312
XCSLE3535312
XCSLE3737312
XCSLE3838312
Connector M23 (4)
XCSLE252531M2
XCSLE272731M2
XCSLE353531M3
XCSLE373731M3
XCSLE383831M3
30
3-pole contact
Slow break
(1NC+2NO)
3-pole contact
Slow break
(2NC+1NO)
Illustration of contacts with the actuator inserted in the head of the switch
Safety interlock switches
Push button version and Push button with connector version
Maximum safety level (3)
Type XCSLF, metal
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
Degree of protection conforming to IEC 60529
Reliability data B10d
Body + Head dimensions (mm) W x D x H
Resistence to forcible withdrawal of actuator
Locking
Push button with or without key no. 455 to release
Power supply for the solenoid and the LEDs
Material case
IP66 IP65
5 500 000 value given for a service life of 20 years, limited by mechanical or contact wear
43,5 x 51 x 205 mm
3 000 N on de-energization (1)
Without
24VAC/DC
Zamak
Wiring connection (2)
Safety contacts
3 x ISO M20
1NC+2NO (break before make, slow break) XCSLF3535412
2NC+1NO (break before make, slow break) XCSLF3737412
(1) For locking on energisation of solenoid, please refer to www.tesensors.com
(2) With cable entry for 1/2" NPT, please refer to www.tesensors.com
(3) Using an appropriate and correctly connected control system.
(4) M23 to XCSLF***M2 products: Connector M23, 16 pin
M23 to XCSLF***M3 products: Connector M23, 19 pin
IP65
Connector M23 (4)
XCSLF353541M3
XCSLF373741M3
IP66 on de-energization (1)
With
3 x ISO M20
XCSLF3535612
XCSLF3737612
Connector M23 (4)
XCSLF353561M3
XCSLF373761M3
Accessories
For safety switches XCSA/B/C/LE/LF
References
Straight actuator
Actuators
XCSZ01
Wide actuator
XCSZ02
Pivoting actuator
XCSZ03
Door lock
XCSZ05
Other versions: please consult our Customer Care Centre.
57
Preventa
Detection
Safety switches with rotary lever or spindle
ISO entry
(to EN 50262)
2-pole contact
Slow break
(1NC+1NO)
20/22
2-pole contact
Slow break
(2NC)
Plastic switches
Stainless steel, elbowed (flush with rear of switch) lever Stainless steel straight lever
Type XCSPL with rotary lever or XCSPR with spindle
1 x ISO M16 cable entry (1) (2)
Maximum safety level (3)
Minimum torque (actuation / positive opening)
Degree of protection IP 67
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15, A 300 / DC 13, Q 300
Dimensions (body + head) W x D x H
Lever position
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
0,1 / 0,25 N.m
30 x 30 x 160 mm
Lever to left Lever centred Lever to right Lever to left or right Lever centred
5° Tripping angle
Reliability data B10d
Complete switch 1NC+1NO break before make, slow break
5 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
2NC slow break
1NC+2NO break before make, slow break
2NC+1NO break before make, slow break
–
–
XCSPL592
XCSPL792
XCSPL582 XCSPL572 XCSPL562
XCSPL782 XCSPL772 XCSPL762
– – XCSPL862
XCSPL982 – XCSPL962
–
–
XCSPL552
XCSPL752
Stainless steel spindle, L = 30 mm
30 x 30 x 96 mm
–
XCSPR552
XCSPR752
–
XCSPR952
3-pole contact
Slow break
(1NC+2NO)
ISO entry
(to EN 50262)
40,3
20/22
3-pole contact
Slow break
(2NC+1NO)
Plastic switches
Stainless steel, elbowed
(flush with rear of switch) lever
Stainless steel straight lever
Type XCSTL with rotary lever or XCSTR with spindle
2 x ISO M16 cable entries (2) (4)
Stainless steel spindle
Length 30 mm
Maximum safety level (3)
Minimum torque (actuation / positive opening)
Degree of protection IP 67
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15, A 300 / DC 13, Q 300
Dimensions (body + head) W x P x H
Lever position
Tripping angle
Reliability data B10d
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
0.1 / 0.45 N.m
52 x 30 x 180 mm
Lever centred
5°
Lever centred
52 x 30 x 117 mm
–
5 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
Complete switch 1NC+2NO break before make, slow break XCSTL582 XCSTL552
2NC+1NO break before make, slow break XCSTL782 XCSTL752
(1) With entry for n° 11 (Pg 11) cable gland, replace the last digit in the reference by 1 (example: XCSPL592 becomes XCSPL591).
(2) For entry for ISO M20 cable gland, also order adaptor DE9RA1620 (sold in lots of 5).
(3) Using an appropriate and correctly connected control system.
(4) With entry for n° 11 (Pg 11) cable gland, replace the last digit in the reference by 1 (example: XCSTL582 becomes XCSTL581).
XCSTR552
XCSTR752
Other versions: please consult our Customer Care Centre.
58
Limit switches
Safety limit switches
GN-YE
3-pole contact
2NC+1NO
Snap action
GN-YE
3-pole contact
2NC+1NO
Slow break
Miniature switches
Maximum safety level (2)
Maximum actuation speed
Minimum force or torque (actuation / positive opening)
Degree of protection
Dimensions (body + head) W x D x H
Reliability data B10d
Complete switch 2NC+1NO snap action
2NC+1NO slow break
Metal end plunger
Type XCSM, metal pre-cabled, L = 1 m (1)
Roller plunger Thermoplastic roller lever
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
0.5 m/s 0.5 m/s 1.5 m/s
8.5 N / 42.5 N
IP 66 + IP 67 + IP 68
7 N / 35 N
IP 66 + IP 67 + IP 68
0.5 N.m / 0.1 N.m
IP 66 + IP 67 + IP 68
30 x 16 x 60 mm 30 x 16 x 70.5 mm 30 x 32 x 92.5 mm
50 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
XCSM3910L1
XCSM3710L1
XCSM3902L1
XCSM3702L1
XCSM3915L1
XCSM3715L1
3-pole contact
2NC + 1NO
Snap action
3-pole contact
2NC + 1NO
Slow break
Compact switches
Metal end plunger
Roller plunger
Type XCSD, metal
1 x ISO M20 x 1.5 cable entry (3)
Thermoplastic Metal roller lever end plunger
Roller plunger
Type XCSP, plastic
1 x ISO M20 x 1.5 cable entry (2)
Thermoplastic roller lever
Maximum safety level (2)
Maximum actuation speed
Minimum force or torque (actuation / positive opening)
Degree of protection
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
0.5 m/s
15 N / 45 N
IP 66 + IP 67
12 N / 36 N
1.5 m/s 0.5 m/s
10 N.m / 0.1 N.m 15 N / 45 N
IP 66 + IP 67
12 N / 36 N
1.5 m/s
10 N.m / 0.1 N.m
Dimensions (body + head) W x D x H (mm)
Reliability data B10d
34 x 34.5 x 89 34 x 34.5 x 99.5
34 x 43 x 121.5
34 x 34.5 x 89 34 x 34.5 x 99.5
50 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
34 x 43 x 121.5
Complete switch 2NC+1NO snap action XCSD3910P20 XCSD3902P20 XCSD3918P20 XCSP3910P20 XCSP3902P20 XCSP3918P20
2NC+1NO slow break XCSD3710P20 XCSD3702P20 XCSD3718P20 XCSP3710P20 XCSP3702P20 XCSP3718P20
(1) For a 2 m long cable, replace the last digit of the reference by 2 (example: XCSM3910L1 becomes XCSM3910L2).
For a 5 m long cable, replace the last digit of the reference by 5 (example: XCSM3910L1 becomes XCSM3910L5).
(2) Using an appropriate and correctly connected control system.
(3) For Pg 13.5 and 1/2" NPT cable entries, refer to www.tesensors.com.
Other versions: please consult our Customer Care Centre.
59
Preventa
Detection
Coded magnetic technology
Plastic coded magnetic system
(1) (1)
F1
1/BN
I1 7/GY +
2 A
NO
O1 4/BK
I2 6/PK +
+
NO O2 2/WH
K2
3/BU
XCSDM3
K1
–
7
6
1
4
3
2
F1
1/BN
Diag
+
Er
I1
NO
7/VT
5/GY
O1
I2
4/BK
6/PK
2 A
+
+
NO
O2 2/WH
K2
+
K1
XCSDM4
6
7
1
8
5
4
3
2
3/BU
8/OG
K2 K1
+
–
Type of system
With integrated safety module
Maximum safety level
SIL2/Category 3
XCSDM3
SIL 2 conforming to EN/IEC 61508,PL=d,
SIL3/Category 4
XCSDM4
SIL 3 conforming to EN/IEC 61508, PL=e, category 3 conforming to EN/ISO 13849-1 category 4 conforming to EN/ISO 13849-1
Switches for actuation
Degree of protection
Type of contact 2 solid-state output PNP/NO, 1,5 A / 24VDC (2 A up to 60°C)
Rated operational characteristics (conforming to EN IEC 60947-5-1) Ub: 24 VDC +10% - 20%
Dimensions W x D x H
Operating zone
Face to face, face to side, side to side
Pre-cabled: IP66 / IP67, IP69K, connector: IP67
34 x 27 x 100 mm
Sao= 10 mm / Sar= 20 mm
Reliability data
References Connection for cable L= 2m
MTTFd = 182 years; PFH = 3.94E -9; PFD = 1.15E -5; SFF = 92.5%; HFT = 1 for cable L= 5m for cable L= 10m for connector M12
XCSDM379102
XCSDM379105
XCSDM379110
XCSDM3791M12
XCSDM480102
XCSDM480105
XCSDM480110
XCSDM4801M12
Plastic coded magnetic
(1) (1)
Contact
(1NC+1NO staggered)
Contact
(1NC+2NO,
1NO staggered)
Contact
(2NC staggered)
Contact
(2NC+1NO,
1NC
staggered) Rectangular Rectangular Cylindrical Rectangular Rectangular Cylindrical
Without LED (2) Without LED (2) Without LED (2) Without LED (2) Without LED (2) Without LED (2)
Plastic switches Type XCSDM coded magnetic
Pre-cabled, L = 2 m Connector on flying lead, L = 15 cm (3)
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508 Maximum safety level (5)
Switches for actuation
Degree of protection
Type of contact
2NC staggered
Face to face, face to side, side to side Face to face
IP 66 + IP 67
REED
Face to face, face to side, side to side Face to face
IP 66 + IP 67
REED
Rated operational characteristics (conforming to EN IEC 60947-5-1) Ue = 24 VDC, Ie = 100 mA
Dimensions W x D x H 16 x 7 x 51 mm 25 x 13 x 88 mm M30 x 38,5 mm
Ue = 24 VDC, Ie = 100 mA
16 x 7 x 51 mm 25 x 13 x 88 mm M30 x 38.5 mm
Operating zone (4)
Reliability data B10d
Switch with coded magnet 1NC+1NO staggered
Sao = 5 / Sar = 15 Sao = 8 / Sar = 20 Sao = 5 / Sar = 15 Sao = 8 / Sar = 20
50 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
XCSDMC5902 XCSDMP5902 XCSDMR5902 XCSDMC590L01M8 XCSDMP590L01M12 XCSDMR590L01M12
XCSDMC7902 XCSDMP7902 XCSDMR7902 XCSDMC790L01M8 XCSDMP790L01M12 XCSDMR790L01M12
1NC+2NO, 1NO staggered – XCSDMP5002 –
2NC+1NO, 1NC staggered – XCSDMP7002 –
(1) Illustration of contacts with the magnet in front of the switch.
(2) For version with LED indicator, replace the last 0 in the reference by 1 (example: XCSDMC5902 becomes XCSDMC5912).
(3) For associated pre-wired female connectors, please refer to the “Preventa XCS safety switches” catalogue.
(4) Sao: assured operating distance. Sar: assured release distance.
(5) Using an appropriate and correctly connected control system
–
–
XCSDMP500L01M12 –
XCSDMP700L01M12 –
Other versions: please consult our Customer Care Centre.
60
Emergency stops
Emergency stop rope pull switches
NC + NO contact slow break
NC + NC contact slow break
For operating cable length < 20 - 30m
Maximum safety level (2)
Mechanical life
Shock / vibration resistance
Degree of protection
Conformity to standards
Dimensions W x D x H
Operating cable length
Operating cable anchoring point
Reliability data B10d
Contact 1 NC + NO slow break
1 NC + NC slow break
2 NC + 1 NO slow break
ISO entry
(to EN 50262)
Latching, without indicator light
Pg 13.5 threaded cable entry
PL e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
100, 000 operating cycles
50 gn / 10 gn
IP 66 and 67
EN/IEC 60947-5-5, EN/ISO 13850, UL (NiSD) - CSA, CCC
200,9 x 40 x 64,2 mm
< 20 m straight
< 30 m right side
< 30 m left side
500, 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
XY2CJS15 (4)
XY2CJS17 (4)
XY2CJS19 (4) (5)
XY2CJR15 (4)
XY2CJR17 (4)
XY2CJR19 (4) (5)
XY2CJL15 (4)
XY2CJL17 (4)
XY2CJL19 (4) (5)
For operating cable length ≤ 30 m
Maximum safety level (2)
Mechanical life
Shock / vibration resistance
Degree of protection
Conformity to standards
Dimensions W x D x H
Operating cable length
Operating cable anchoring point
Reliability data B10d
Contact 1 NC + NO slow break
1 NC + NC slow break
2 NC + 1 NO slow break
Booted pushbutton reset
Latching, without indicator light
3 x ISO M20 cable entries (1)
Key release pushbutton reset (key n° 421) with indicator light
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508
800 000 operating cycles
50 gn / 10 gn
IP 65
EN/IEC 60947-5-5, EN/ISO 13850: 2006, UL 508 and CSA C 22-2 n° 14 (with suffix H7)
201 x 71 x 68 mm
≤ 30 m
To right or to left
4 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
XY2CH13250H29
XY2CH13270H29
XY2CH13290H29
XY2CH13450H29
XY2CH13470H29
–
XY2CH13253
XY2CH13273
XY2CH13293H29
Booted pusbutton reset Key release pushbutton reset (key n° 421)
For operating cable length ≤ 70 m Latching, without indicator light
3 plain holes with Pg13,5 cable entries
Maximum safety level (2)
Mechanical life (millions of operating cycles)
Shock / vibration resistance
Degree of protection
Conformity to standards
Dimensions W x D x H
Operating cable length
Operating cable anchoring point
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL 3 conforming to EN/IEC 61508
0.01
50 gn / 10 gn
IP 65
EN/IEC 60947-5-5, EN/ISO 13850: 2006, UL 508 and CSA C 22-2 n° 14 (with suffix H7)
229 x 82 x 142 mm
≤ 70 m
To left To right To left To right
Reliability data B10d
Contact 1 NC + NO slow break
1 NC + NC slow break
50.000 (value given for a service life of 20 years, limited by mechanical or contact wear)
XY2CE2A250
XY2CE2A270
XY2CE1A250
XY2CE1A270
XY2CE2A450
XY2CE2A470
XY2CE1A450
XY2CE1A470
2 NC + NO slow break XY2CE2A290 (3) XY2CE1A290 (3) XY2CE2A490 (3) XY2CE1A290 (3)
(1) With entry for n° 13 (Pg 13.5) cable gland, delete H29 from the end of the reference (example: XY2-CH13250H29 becomes XY2-CH13250). (2) Using an appropriate and correctly connected control system. (3) With protected LED, 24V or 130 V supply voltage pilot light, add 6 at the end of the reference. (example : XY2CE1A290 becomes XY2CE1A296). With protected LED, 230 V supply voltage pilot light, add 7 at the end of the reference. (example : XY2CE1A290 becomes XY2CE1A297). (4) For ISO M20 threaded cable entry version, add H29 to the end of the reference selected. Example:
XY2CJS15 becomes XY2CJS15H29. (5) For 1/2” NPT threaded cable entry version, add H7 to the end of the reference selected. Example: XY2CJS19 becomes XY2CJS19H7.
Other versions: please consult our Customer Care Centre.
61
Preventa
Detection
Light curtains
Type 2 conforming to IEC 61496-1 & IEC 61496-2
Main features (1) b Automatic or Manual Start/Restart selectable by wiring b External Device Monitoring (EDM) selectable by wiring b Two maximum Sensing Distance selectable by wiring b Test function (beam blocked state simulation) b Led indicators for status and diagnosis b Muting possible with dedicated Safety module
Maximum safety level achieved by the solution
EN ISO 13849-1
Maximum safety level achieved by the solution
IEC 61508/IEC 62061
Type
IEC 61496-1 & IEC 61496-2
Nominal sensing distance (Sn)
Resolution (detection capability)
Number of safety outputs
Response time (depending on model)
Operating temperature range
Degree of protection
Connection
Reliability data
Mission time
Height protected (mm)
PLd/cat2
SIL2/SILCL2
Type 2 Multi-beam, infrared transmission
0…4 m or 0…12 m selectable
30 mm (Hand detection)
2 solid-state PNP
4.5…23.5 ms
-10°C…+55°C
IP65-IP67
M12 Connector
PFHd = 2.04E-8 to 8.98E-8
TM = 20 years
160
260
310
460
XUSL2E30H016N
XUSL2E30H026N
XUSL2E30H031N
XUSL2E30H046N
510 - 2 beams –
2-3 or 4 Beams (Body Detection)
3…3.5 ms
PFHd = 1.71E-8 to 2.02E-8
–
–
–
–
XUSL2E2BB051N
– 610
760
XUSL2E30H061N
XUSL2E30H076N
810 - 3 beams –
910 XUSL2E30H091N
910 - 4 beams –
1060
–
XUSL2E3BB081N
–
XUSL2E4BB091N
–
1210
1360
1510
1660
1810
XUSL2E30H106N
XUSL2E30H121N
XUSL2E30H136N
XUSL2E30H151N
XUSL2E30H166N
XUSL2E30H181N
–
–
–
–
–
Type 2 conforming to IEC 61496-1 et 2
Light curtain functions b Auto/Manual, b Monitoring of external switching devices
(EDM: External Devices Monitoring), b LED display of operating modes b Integral muting function.
Maximum safety level achieved by the solution
(EN ISO 13849-1, EN/IEC 62061)
Type
PLc/cat2, SILCL1
Single-beam with infrared emission
Height protected (conforming to prEN 999)
Nominal sensing distance (Sn)
Number of circuits Safety
Additional
Response time
Reliability data
Modules (integral muting function)
Thru-beam pairs, axially aligned
Pre-cabled, L = 5m
M12 connector
750…1200 mm (1 to 4 beams)
8 m
2N/O
4 solid-state
< 25 ms
PFHd = 4.6E -7 conforming to EN/IEC 61508
PFHd = 5.5E -7 conforming to EN/IEC 61508, with "muting" function
24 VDC XPSCM1144P (2)
PNP XU2S18PP340L5 (3)
PNP XU2S18PP340D (3)
(1) Also exists in IP69k model. (2) For version with non removable terminal block, delete the letter P from the end of the reference. Example: XPSCM1144P becomes XPSCM1144).
(3) For alignment at 90° to the mounting axes, insert the letter W in the reference before the last letter. Example: XU2S18PP340L5 becomes XU2S18PP340WL5).
Other versions: please consult our Customer Care Centre.
62
Type 4 conforming to IEC 61496-1 & IEC 61496-2
Main features (1) b Automatic or Manual Start/Restart selectable by wiring b External Device Monitoring (EDM) selectable by wiring b Two maximum Sensing Distance selectable by wiring b Test function (beam blocked state simulation) b Led indicators for status and diagnosis b Muting possible with dedicated Safety module
Maximum Safety level achieved by the solution
EN ISO 13849-1
Maximum Safety level achieved by the solution
IEC 61508/IEC 62061
Type
IEC 61496-1 & IEC 61496-2
Nominal sensing distance (Sn)
PLe/cat4
SIL3/SILCL3
Type4 Multi-beam, infrared transmission
0…3 m or 1…6 m selectable
Resolution (detection capability)
Number of safety outputs
Response time (depending on model)
Operating temperature range
14 mm (Finger detection)
2 solid-state PNP
4…23.5 ms
-10°C…+55°C
Degree of protection
Connection
Height protected (mm) 160
260
IP65-IP67
M12 Connector
Reliability data (depending on model) conforming to EN/IEC 61508 PFHd = 1.03E-8 to 3.71E-8
Mission time TM = 20 years
XUSL4E14F016N
–
310
460
XUSL4E14F031N
XUSL4E14F046N
510 - 2 beams –
0…4 m or 0…12 m selectable
30 mm (Hand detection)
4…22 ms
PFHd = 7.08E-9 to 2.02E-8
XUSL4E30H016N
XUSL4E30H026N
XUSL4E30H031N
XUSL4E30H046N
–
610
760
XUSL4E14F061N
XUSL4E14F076N
810 - 3 beams –
910 XUSL4E14F091N
910 - 4 beams –
1060
1210
1360
1510
1660
1810
XUSL4E14F106N
XUSL4E14F121N
XUSL4E14F136N
XUSL4E14F151N
XUSL4E14F166N
XUSL4E14F181N
XUSL4E30H061N
XUSL4E30H076N
–
XUSL4E30H091N
–
XUSL4E30H106N
XUSL4E30H121N
XUSL4E30H136N
XUSL4E30H151N
XUSL4E30H166N
XUSL4E30H181N
Type
Nominal sensing distance (Sn)
Reliability data (depending on model) conforming to EN/IEC 61508
Response time (depending on model)
Height protected (mm)
Long Range models
For hand and body protection
0…10 m or 3…20 m selectable
PFHd = 9.13E-9 to 2.29E-8
0…4 m or 0…12 m selectable
2-3 or 4 Beams (Body Detection)
2.5…3 ms
PFHd = 6.89E-9 to 8.21E-9
–
–
–
–
–
–
–
–
–
XUSL4E2BB051N
–
–
XUSL4E3BB081N
–
XUSL4E4BB091N
–
0…10 m or 3…20 m selectable
PFHd = 9.15E-9 to 1.08E-8
3…13 ms
160
310
XUSL4E30H016L
XUSL4E30H031L
460 XUSL4E30H046L
510 - 2 beams –
610
760
XUSL4E30H061L
XUSL4E30H076L
810 - 3 beams –
910 XUSL4E30H091L
910 - 4 beams –
1060
1210
1360
1510
1660
1810
XUSL4E30H106L
XUSL4E30H121L
XUSL4E30H136L
XUSL4E30H151L
XUSL4E30H166L
XUSL4E30H181L
–
–
–
–
–
–
–
2.5 ms
–
XUSL4E2BB051L
–
–
XUSL4E3BB081L
–
XUSL4E4BB091L
–
(1) Also exists in IP69K model.
Other versions: please consult our Customer Care Centre.
63
Preventa
Detection
Light curtains
Type 4 conforming to IEC 61496-1 & IEC 61496-2
Main features (1) b Automatic or Manual Start/Restart selectable by wiring b External Device Monitoring (EDM) selectable by wiring b Two maximum Sensing Distance selectable by wiring b Test function (beam blocked state simulation) b Led indicators for status and diagnosis b Muting possible with dedicated Safety module
Type
M S2 S1
Cascadable models - Master Segments (2)
Nominal sensing distance (Sn)
Resolution (detection capability)
Number of safety outputs
Response time
0…3 m or 1…6 m selectable
14 mm (Finger detection)
2 solid-state PNP
Depends on the number and the model of segments used. See the “User Manual” for the calculation
Operating temperature range
Degree of protection
Connection 2xM12 Connector
Reliability data (depending on model)conforming to EN/IEC 61508 PFHd = 1.27E-8 to 2E-8
Mission time
Height protected (mm) (2) 310
460
-10°C…+55°C
IP65-IP67
TM = 20 years
XUSL4E14F031NM
XUSL4E14F046NM
510 - 2 beams –
0…4 m or 0…12 m selectable
30 mm (Hand detection)
PFHd = 9.47E-9 to 1.43E-8
–
XUSL4E30H046NM
–
0…4 m or 0…12 m selectable
2-3 or 4 Beams (Body Detection)
PFHd = 6.89E-9 to 8.21E-9
–
–
XUSL4E2BB051NM
– 610
760
XUSL4E14F061NM
XUSL4E14F076NM
810 - 3 beams –
910 –
910 - 4 beams –
1060 –
XUSL4E30H061NM
XUSL4E30H076NM
–
XUSL4E30H091NM
–
XUSL4E30H106NM
–
XUSL4E3BB081NM
–
XUSL4E4BB091NM
–
Type
Reliability data (depending on model) conforming to EN/IEC 61508
Response time
Connection
Height protected (mm) (1)
Cascadable models - Slave1 Segments (2)
PFHd = 1.27E-8 to 2E-8 PFHd = 9.47E-9 to 1.43E-8 PFHd = 6.89E-9 to 8.21E-9
Type
Reliability data (depending on model) conforming to EN/IEC 61508
Response time
Connection
Height protected (mm) (1)
Depends on the number and the models of segments used. See the “User Manual” for the calculation
M12 Connector
310
460
XUSL4E14F031NS1
XUSL4E14F046NS1
510 - 2 beams –
610
760
XUSL4E14F061NS1
XUSL4E14F076NS1
810 - 3 beams –
910 –
910 - 4 beams –
1060 –
–
XUSL4E30H046NS1
–
XUSL4E30H061NS1
XUSL4E30H076NS1
–
XUSL4E30H091NS1
–
XUSL4E30H106NS1
–
–
XUSL4E2BB051NS1
–
–
XUSL4E3BB081NS1
–
XUSL4E4BB091NS1
–
Cascadable models - Slave2 Segments (2)
PFHd = 1.52E-8 to 2E-8 PFHd = 9.47E-9 to 1.43E-8 PFHd = 6.89E-9 to 8.21E-9
310
460
Depends on the number and the models of segments used. See the “User Manual” for the calculation
2xM12 Connector
XUSL4E14F046NS2
510 - 2 beams –
–
XUSL4E30H046NS2
–
–
–
610
760
XUSL4E14F061NS2
XUSL4E14F076NS2
810 - 3 beams –
XUSL4E30H061NS2
XUSL4E30H076NS2
–
XUSL4E2BB051NS2
–
–
910
1060
–
910 - 4 beams –
–
XUSL4E30H091NS2
–
XUSL4E30H106NS2
XUSL4E3BB081NS2
–
XUSL4E4BB091NS2
–
(1) Other Heights available on request
(2) cable sold separately, please refer to Page 65
Other versions: please consult our Customer Care Centre.
64
Cabling accessories
Type
Cable length
M12 connector 5 pins
Female
M12 connector 8 pins
Female
Straight - Pre-wired
90° - Pre-wired
Straight - Pre-wired
90° - Pre-wired
XZCP29P11L●●
M12 connector - Pre-wired
XZCP1164L●
2 m
For transmitter XZCP1164L2
For transmitter XZCP1264L2
For receiver
For receiver
XZCP29P11L2
XZCP53P11L2
5 m
XZCP1164L5
XZCP1264L5
XZCP29P11L5
XZCP53P11L5
10 m
XZCP1164L10
XZCP1264L10
XZCP29P11L10
XZCP53P11L10
XZCP1264L●
15 m
XZCP1164L15
XZCP1264L15
XZCP29P11L15
XZCP53P11L15
25 m
XZCP1164L25
XZCP1264L25
XZCP29P11L25
XZCP53P11L25
Type
XZCC12FDM50B XZCC12FCM50B
M12 connector - with screw terminals
Cable length
M12 connector 5 pins
Female
M12 connector 8 pins
Female
90° - 5 poles with screw terminals- cable gland
Straight - 5 poles with screw terminals- cable gland
For transmitter
2 m
XZCC12FCM50B
For transmitter XZCC12FDM50B
XZCC12FCM80B 90° - 8 poles with screw terminals- cable gland
Straight - 8 poles with screw terminals- cable gland
For receiver
For receiver XZCC12FDM80B
Type
Cable length
2 straight M12 - Female/Female connectors - 5 poles
For Master/Slave cascadable segments
2xM12 connectors - Jumpers
0.3 m 3 m
XZCR1111064D03 XZCR1111064D3
5 m
XZCR1111064D5
10 m 25 m
XZCR1111064D10 XZCR1111064D25
Other versions: please consult our Customer Care Centre.
65
Preventa
Detection
Safety modules for monitoring emergency stops and limit switches
Maximum safety level of the solution attained
(EN ISO 13849-1, EN/IEC 62061)
Number of circuits Safety
PL e / Cat. 4, SILCL 3
Display (number of LEDs)
Width of housing
Additional
3 N/O 3 N/O
1 solid-state 1 N/C
2
22.5 mm
2
22.5 mm
3 N/O
–
3
22.5 mm
3 N/O
1 N/C
+ 4 solid-state
4
45 mm
7 N/O
2 N/C
+ 4 solid-state
4
90 mm
3 N/O + 3 N/O time del.
2 N/O + 1 N/O time del.
2 N/O + 3 N/O time del.
3 solid-state
11
45 mm
-
3
22.5 mm
4 solid-state
4
45 mm
Optimum solutions: safety modules (for monitoring 1 safety function)
Supply voltage (1) 24 VDC
24 VAC/DC
230 VAC –
– – – –
XPSAC5121P XPSAXE5120P (2) XPSAF5130P XPSAK311144P XPSAR311144P –
XPSAV11113P XPSABV11330P (2) –
– XPSATE5110P
– – – – – – XPSATE3710P
(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSAV11113P becomes XPSAV11113).
(2) For a version with spring terminals, replace the letter P with the letter C at the end of the reference (example: XPSAXE5120P becomes XPSAXE5120C) coded magnetic switches
Maximum safety level of the solution attained
(EN ISO 13849-1, EN/IEC 62061)
For monitoring
Number of circuits
Display (number of LEDs)
Width of housing
Safety
Additional
PL e / Cat. 4, SILCL 3
2 coded magnetic switches maximum N/C + N/O
2 N/O
2 solid-state
3
22.5 mm
6 coded magnetic switches maximum N/C + N/O
2 N/O
2 solid-state
15
45 mm
6 coded magnetic switches maximum 2 N/C
-
3 N/O
3
22.5 mm
Optimum solutions: safety modules (for monitoring 1 safety function)
Supply voltage 24 VDC XPSDMB1132P (1) XPSDME1132P (1) XPSVC1132P (1)
(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSDMB1132P becomes XPSDMB1132).
Other versions: please consult our Customer Care Centre.
66
Safety modules for monitoring light curtains
Maximum safety level of the solution attained
(EN ISO 13849-1, EN/IEC 62061)
Number of circuits Safety
Additional
Display (number of LEDs)
Width of housing
Integral Muting function
PL c / Cat. 2, SILCL 1 PL e / Cat. 4, SILCL 3
2 N/O
4 solid-state
4
45 mm
Yes
3 N/O
–
3
22.5 mm
No
3 N/O
1 N/C + 4 solid-state
4
45 mm
No
Optimum solutions: safety modules (for monitoring 1 safety function)
Supply voltage 24 VDC
24 VAC/DC
XPSCM1144P (1)
–
–
XPSAFL5130P (1)
–
XPSAK311144P (1)
(1) For version with non removable terminal block, delete the letter P from the end of the reference (example: XPSCM1144P becomes XPSCM1144).
zero speed, time delay and lifts
7 N/O
1 N/C + 4 solid-state
4
90 mm
No
–
XPSAR311144P (1)
1,0
0,8
0,6
0,4
0,2
0,0
Maximum safety level of the solution attained
(EN ISO 13849-1, EN/IEC 62061)
For monitoring
Number of circuits Safety
Additional
Display (number of LEDs)
Width of housing
PL d / Cat. 3, SILCL 2
Motor zero speed condition Safety time delay
1 N/O + 1 N/C 1 N/O time delay
2 solid-state
4
45 mm
2 N/C + 2 solid-state
4
45 mm
Optimum solutions: safety modules (for monitoring 1 safety function)
Supply voltage 24 VDC
24 VAC/DC
XPSVNE1142P (1)
–
(1) Motor frequency ≤ 60 Hz.. For frequencies ≥ 60 Hz, please refer to the “Safety solution” catalogue.
(2) Removable terminal block version only.
–
XPSTSA5142P (2)
1 N/O pulse
2 N/C + 2 solid-state
4
45 mm
PL e / Cat. 4, SILCL 3
Lifts
2 N/O
2 solid-state
4
22.5 mm
–
XPSTSW5142P (2)
–
XPSEDA5142
Other versions: please consult our Customer Care Centre.
67
Main sectors of activity subject to a higher risk of explosion or fire
Flour mills Wood and aluminium workshops
Bagging Grain silos
68
Grain drying areas Bulk conveying
Other versions: please consult our Customer Care Centre.
Explosive atmospheres
A reference for installations in ATEX Dust explosive atmospheres.
What is an explosive atmosphere according to the Directive?
It is the mixing with air, in atmospheric conditions, of flammable substances in the form of gas, vapour, mist or dust which, in the event of combustion, spreads throughout the non burning mix.
Implementation of European Directives
● Directive 99/92/EC
This requires that a risk analysis be performed for all industrial processes. If there is any risk of an explosion:
● the zones are defined and physically identified,
● the installation is classified by governing bodies.
● Directive 94/9/EC
This requires certification of the products in accordance with the classification of the zones of use
● Dust zones
● Zone 20: area where an explosive atmosphere exists in the form of combustible clouds of dust in the air, either permanently, for long periods or frequently.
● Zone 21: area where an explosive atmosphere exists in the form of combustible clouds of dust in the air during normal operation occasionally.
● Zone 22: area where an explosive atmosphere in the form of combustible clouds of dust in the air is unlikely to occur during normal operation but, if it does occur, it is only for a short period.
ZONE 20
ZONE 21
ZONE 22
The products in this catalogue are certified by a European
Union Commission notified body.
A selection of certified products, conforming to the European Directive ATEX94/9/EC, to ensure maximum safety for your installations in a zone where the risk of explosion or fire is high.
Other versions: please consult our Customer Care Centre.
69
Limit switches
Miniature, fixing by the body
OsiSense XC
Limit switch type
With head for movement
Conformity
Zone D (dust)
EC type examination certificate number / marking
Type of operator
XCMD metal, pre-cabled
Linear (plunger)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal end Metal end Steel roller plunger plunger with elastomer boot plunger
Mechanical durability (millions of operating cycles)
Actuation speed
Switches conforming to standard IEC 947-5-1 section 3
Temperature range
10
0.5 m/s
– 20...+ 60°C
Degree of protection (conforming to IEC 60529) IP66 and IP67
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; C300 (Ue = 240 V, Ie = 0.75 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection
Cable entry
By 6 A cartridge fuse type gG (gl)
Pre-cabled, adjustable direction, length = 5 m
20 mm Fixing centres
Body dimensions, W x D x H
References 2NC+2NO snap action
30 x 16 x 50 mm
XCMD4110L5EX XCMD4111L5EX XCMD4102L5EX
Retractable steel roller lever plunger
XCMD4124L5EX
Compact, fixing by the body
XCMD metal, pre-cabled
Rotary (lever)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Steel roller Thermoplastic roller Roller lever lever lever with ball bearing mounted roller
10
1.5 m/s
Variable length thermoplastic roller lever
– 20...+ 60°C
IP66 and IP67
AC15; C300 (Ue = 240 V, Ie = 0.75 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
By 6 A cartridge fuse type gG (gl)
Pre-cabled, adjustable direction, length = 5 m
20 mm
30 x 16 x 50 mm
XCMD4116L5EX XCMD4115L5EX XCMD4117L5EX XCMD4145L5EX
Linear (plunger)
M12 with metal end plunger
0.5 m/s
M16 with metal end plunger with elastomer boot
M12 with steel roller plunger
0.1 m/s
M12 x 1
XCMD41F0L5EX
M16 x 1
XCMD41G1L5EX
M12 x 1
XCMD41F2L5EX
Compact, fixing by the head
Limit switch type
With head for movement
Conformity
Zone D (dust)
EC type examination certificate number / marking
Type of operator
XCKD metal conforming to standard EN 500047
Linear (plunger)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal end Metal end Steel roller Thermoplastic roller Thermoplastic roller plunger plunger with elastomer boot plunger lever plunger, horiz. lever plunger, vert.
actuation in 1 direct. actuation in 1 direct.
Mechanical durability (millions of operating cycles)
Actuation speed
Switches conforming to standard IEC 947-5-1 section 3
Temperature range
15
0.5 m/s
– 20...+ 60°C
10 15
1 m/s
Degree of protection (conforming to IEC 60529) IP66 and IP67
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection
Cable entry
By 6 A cartridge fuse type gG (gl)
1 entry fitted with ISO M16 cable gland
20 mm Fixing centres
Body dimensions, W x D x H
References 2NC+1NO snap action
31 x 30 x 65 mm
XCKD3910P16EX XCKD3911P16EX XCKD3902P16EX XCKD3921P16EX XCKD3927P16EX
Other characteristics: please refer to the “Detection for OsiSense automation solutions” catalog
70
Other versions: please consult our Customer Care Centre.
XCKD metal conforming to standard EN 500047
Linear (plunger) Rotary (lever)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Thermoplastic roller Thermoplastic Thermoplastic lever plunger, horiz. or roller lever vert. actuation in 1 dir.
roller lever,
Ø 50 mm
15
1 m/s
10
1.5 m/s
Variable length thermoplastic roller lever
Multi-directional
Variable length thermoplastic roller lever, Ø 50 mm
“Cat’s whisker”
5
1 m/s
–
Linear (plunger)
M18 with metal end plunger
10
0.5 m/s
M18 with steel roller plunger
– 20...+ 60°C
IP66 and IP67
AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
By 6 A cartridge fuse type gG (gl)
1 entry fitted with ISO M16 cable gland
20 mm
30 x 16 x 50 mm
XCKD3928P16EX XCKD3918P16EX XCKD3939P16EX XCKD3945P16EX XCKD3949P16EX XCKD3906P16EX
M18 x 1
XCKD39H0P16EX XCKD39H2P16EX
Miniature, fixing by the head
Limit switch type
With head for movement
Conformity
Zone D (dust)
EC type examination certificate number / marking
Type of operator
XCMD metal, pre-cabled
Linear (plunger)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal end Metal end Steel roller plunger plunger with elastomer boot plunger
Mechanical durability (millions of operating cycles)
Actuation speed
Switches conforming to standard IEC 947-5-1 section 3
Temperature range
10
0.5 m/s
– 20...+ 60°C
Degree of protection (conforming to IEC 60529) IP66 and IP67
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; C300 (Ue = 240 V, Ie = 0.75 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection
Cable entry
By 6 A cartridge fuse type gG (gl)
Pre-cabled, adjustable direction, length = 5 m
20 mm Fixing centres
Body dimensions, W x D x H
References 2NC+2NO snap action
30 x 16 x 50 mm
XCMD4110L5EX XCMD4111L5EX XCMD4102L5EX
Retractable steel roller lever plunger
XCMD4124L5EX
Compact, fixing by the body
XCMD metal, pre-cabled
Rotary (lever)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Steel roller Thermoplastic roller Roller lever lever lever with ball bearing mounted roller
10
1.5 m/s
Variable length thermoplastic roller lever
– 20...+ 60°C
IP66 and IP67
AC15; C300 (Ue = 240 V, Ie = 0.75 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
By 6 A cartridge fuse type gG (gl)
Pre-cabled, adjustable direction, length = 5 m
20 mm
30 x 16 x 50 mm
XCMD4116L5EX XCMD4115L5EX XCMD4117L5EX XCMD4145L5EX
Linear (plunger)
M12 with metal end plunger
0.5 m/s
M16 with metal end plunger with elastomer boot
M12 with steel roller plunger
0.1 m/s
M12 x 1
XCMD41F0L5EX
M16 x 1
XCMD41G1L5EX
M12 x 1
XCMD41F2L5EX
Compact, fixing by the head
Limit switch type
With head for movement
Conformity
Zone D (dust)
EC type examination certificate number / marking
Type of operator
XCKD metal conforming to standard EN 500047
Linear (plunger)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal end Metal end Steel roller Thermoplastic roller Thermoplastic roller plunger plunger with elastomer boot plunger lever plunger, horiz. lever plunger, vert.
actuation in 1 direct. actuation in 1 direct.
Mechanical durability (millions of operating cycles)
Actuation speed
Switches conforming to standard IEC 947-5-1 section 3
Temperature range
15
0.5 m/s
– 20...+ 60°C
10 15
1 m/s
Degree of protection (conforming to IEC 60529) IP66 and IP67
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection
Cable entry
By 6 A cartridge fuse type gG (gl)
1 entry fitted with ISO M16 cable gland
20 mm Fixing centres
Body dimensions, W x D x H
References 2NC+1NO snap action
31 x 30 x 65 mm
XCKD3910P16EX XCKD3911P16EX XCKD3902P16EX XCKD3921P16EX XCKD3927P16EX
Other characteristics: please refer to the “Detection for OsiSense automation solutions” catalog
XCKD metal conforming to standard EN 500047
Linear (plunger) Rotary (lever)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Thermoplastic roller Thermoplastic Thermoplastic lever plunger, horiz. or roller lever vert. actuation in 1 dir.
roller lever,
Ø 50 mm
15
1 m/s
10
1.5 m/s
Variable length thermoplastic roller lever
Multi-directional
Variable length thermoplastic roller lever, Ø 50 mm
“Cat’s whisker”
5
1 m/s
–
Linear (plunger)
M18 with metal end plunger
10
0.5 m/s
M18 with steel roller plunger
– 20...+ 60°C
IP66 and IP67
AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
By 6 A cartridge fuse type gG (gl)
1 entry fitted with ISO M16 cable gland
20 mm
30 x 16 x 50 mm
XCKD3928P16EX XCKD3918P16EX XCKD3939P16EX XCKD3945P16EX XCKD3949P16EX XCKD3906P16EX
M18 x 1
XCKD39H0P16EX XCKD39H2P16EX
Other versions: please consult our Customer Care Centre.
71
Limit switches
Classic, fixing by the body
OsiSense XC
Limit switch type
With head for movement
Conformity
Zone D (dust)
EC type examination certificate number / marking
Type of operator
XCKM metal, 3 cable entries
Linear (plunger)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
Rotary (lever)
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal end Steel roller Thermoplastic roller Thermoplastic
Multi-directional
“Cat’s whisker” plunger plunger lever plunger, horiz. roller lever actuation in 1 direct.
Mechanical durability (millions of operating cycles)
Actuation speed
Switches conforming to standard IEC 947-5-1 section 3
Temperature range
20
0.5 m/s
– 20...+ 60°C
1.5 m/s
Degree of protection (conforming to IEC 60529) IP66
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection
Cable entry
By 6 A cartridge fuse type gG (gl)
3 tapped entries for ISO M20 cable gland (1)
10
0.5 m/s
–
Fixing centres
Body dimensions, W x D x H
41 mm
63 x 30 x 64 mm
References 2NC+1NO snap action XCKM3910H29EX XCKM3902H29EX XCKM3921H29EX XCKM3915H29EX XCKM3906H29EX
(1) 2 entries fitted with blanking plugs, 1 entry fitted with ISO M20 cable gland
Application - hoisting, handling, conveying
Limit switch type
With head for movement
Conformity
Zone D (dust)
EC type examination certificate number / marking
Type of operator
XCKMR metal, 3 cable entries
Rotary (lever)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal rod levers, ”crossed” Metal rod levers, ”crossed” reversed head
Mechanical durability (millions of operating cycles)
Actuation speed
2
1.5 m/s
Switches conforming to standard IEC 947-5-1 section 3
Temperature range
Degree of protection (conforming to IEC 60529)
– 20...+ 60°C
IP66
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; A300 (Ue = 240 V, Ie = 3 A)/DC13; Q300 (Ue = 125 V, Ie = 0.55 A)
Short-circuit protection
Cable entry
Fixing centres
Body dimensions, W x D x H
By 10 A cartridge fuse type gG (gl)
3 tapped entries for ISO M20 cable gland (1)
61.5 mm
118 x 59 x 77 mm
2 (NC+NC) staggered, slow break contacts
2 (NC+NO) snap action contacts, both actuated in each direction
2 (NC+NO) snap action contacts, 1 actuated in each direction
2 CO staggered snap action contacts
–
–
XCKMR54D1H29EX
–
XCKMR54D2H29EX
(1) 2 entries fitted with blanking plugs, 1 entry fitted with ISO M20 cable gland
Other characteristics: please refer to the “Detection for OsiSense automation solutions” catalog.
72
Other versions: please consult our Customer Care Centre.
Limit switch type
With head for movement
Conformity
Zone D (dust)
EC type examination certificate number / marking
Type of operator
XCKM metal, 3 cable entries
Linear (plunger)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
Rotary (lever)
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal end Steel roller Thermoplastic roller Thermoplastic
Multi-directional
“Cat’s whisker” plunger plunger lever plunger, horiz. roller lever actuation in 1 direct.
Mechanical durability (millions of operating cycles)
Actuation speed
Switches conforming to standard IEC 947-5-1 section 3
Temperature range
20
0.5 m/s
– 20...+ 60°C
1.5 m/s
Degree of protection (conforming to IEC 60529) IP66
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection
Cable entry
By 6 A cartridge fuse type gG (gl)
3 tapped entries for ISO M20 cable gland (1)
10
0.5 m/s
–
Fixing centres
Body dimensions, W x D x H
41 mm
63 x 30 x 64 mm
References 2NC+1NO snap action XCKM3910H29EX XCKM3902H29EX XCKM3921H29EX XCKM3915H29EX XCKM3906H29EX
(1) 2 entries fitted with blanking plugs, 1 entry fitted with ISO M20 cable gland
Application - hoisting, handling, conveying
XCKJ metal, fixed body, conforming to standard EN 50041
Linear (plunger) Rotary (lever)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal end Steel roller Steel roller plunger plunger lever
30
0.5 m/s
25
1 m/s
30
1.5 m/s
– 20...+ 60°C
IP66
AC15; B300 (Ue = 240 V, Ie = 1.5 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
By 6 A cartridge fuse type gG (gl)
1 entry fitted with ISO M20 cable gland
30 x 60 mm
40 x 44 x 77 mm
XCKJ3961H29EX XCKJ3967H29EX XCKJ390513H29EX
Thermoplastic roller lever
XCKJ390511H29EX
Variable length thermoplastic roller lever
20
–
Polyamide rod lever, Ø 6 x 200 mm
XCKJ390541H29EX XCKJ390559H29EX
Limit switch type
With head for movement
Conformity
Zone D (dust)
EC type examination certificate number / marking
Type of operator
XCKMR metal, 3 cable entries
Rotary (lever)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP66/67
Metal rod levers, ”crossed” Metal rod levers, ”crossed” reversed head
Mechanical durability (millions of operating cycles)
Actuation speed
2
1.5 m/s
Switches conforming to standard IEC 947-5-1 section 3
Temperature range
Degree of protection (conforming to IEC 60529)
– 20...+ 60°C
IP66
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; A300 (Ue = 240 V, Ie = 3 A)/DC13; Q300 (Ue = 125 V, Ie = 0.55 A)
Short-circuit protection
Cable entry
Fixing centres
Body dimensions, W x D x H
By 10 A cartridge fuse type gG (gl)
3 tapped entries for ISO M20 cable gland (1)
61.5 mm
118 x 59 x 77 mm
2 (NC+NC) staggered, slow break contacts
2 (NC+NO) snap action contacts, both actuated in each direction
2 (NC+NO) snap action contacts, 1 actuated in each direction
2 CO staggered snap action contacts
–
–
XCKMR54D1H29EX
–
XCKMR54D2H29EX
(1) 2 entries fitted with blanking plugs, 1 entry fitted with ISO M20 cable gland
Other characteristics: please refer to the “Detection for OsiSense automation solutions” catalog.
XCR metal
Rotary (lever)
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0024X / D-Ex tb C T85°C Db IP66
Square (6 mm) Thermoplastic roller Large thermoplastic roller rod lever, spring return to off position
10
1.5 m/s
(Ø 30 mm) lever, spring return to off position
(Ø 50 mm) lever, spring return to off position
– 20...+ 60°C
IP65
AC15; A300 (Ue = 240 V, Ie = 3 A)/DC13; Q300 (Ue = 250 V, Ie = 0.27 A)
By 10 A cartridge fuse type gG (gl)
1 entry fitted with n° 13 cable gland
85 x 75 mm
85 x 75 x 95 mm
–
XCRA111EX
XCRB111EX
–
(2) “Crossed” rods (3) “T” rods
XCRA121EX
XCRB121EX
XCRA151EX
XCRB151EX
Metal rod levers,
”crossed”, stay put
XCRE181EX (2)
XCRF171EX (3)
Conveyor belt shift monitoring switches
Galvanised steel operating lever
0.3
–
–
–
XCRT115EX
Stainless steel operating lever
XCRT215EX
Other versions: please consult our Customer Care Centre.
73
Electromechanical pressure & vacuum switches
Adjustable differential, regulation between 2 thresholds
OsiSense XM
Type
Size
Conformity
Vacuum switches and vacu-pressure switches with setting scale
- 1 bar - 0.2 bar
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
5 bar
Zone D (dust)
EC type examination certificate number / marking
Fluid connection
Electrical connection
21 - 22
INERIS 04ATEX0058 / D-Ex tb C T85°C Db IP66
1/4” BSP female
Screw terminals, 1 entry fitted with ISO M20 cable gland
Temperature range
Degree of protection
Setting range of upper limit (PH)
Body dimensions, W x D x H
– 20...+ 60°C
IP66
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection By 10 A cartridge fuse type gG (gl)
–0.14…–1 bar
55 x 77.5 x 158 mm
–0.02…–0.2 bar
150 x 155.5 x 145 mm
–0.5…5 bar
113 x 35 x 75 mm
Oil, water, air, up to +70°C Oil, air, up to +160°C Oil, water, air, up to +70°C Fluids controlled
Possible differential
(subtract from PH to give PB) (1)
Min. at low setting
Min. at high setting
Max. at high setting
0.13 bar
0.13 bar
0.8 bar
0.018 bar
0.018 bar
0.18 bar
0.5 bar
0.5 bar
6 bar
1 CO single pole, snap action contact XMLBM02V2S12EX
(1) For XMLBM02V2S12EX and XMLBM03R2S12EX vacuum switches add to PB to give PH
XMLBM03R2S12EX XMLBM05A2S12EX
Type
Size
Conformity
Pressure switches with setting scale
10 bar 20 bar
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
35 bar
Zone D (dust)
EC type examination certificate number / marking
Fluid connection
Electrical connection
21 - 22
INERIS 04ATEX0058 / D-Ex tb C T85°C Db IP66
1/4” BSP female
Screw terminals, 1 entry fitted with ISO M20 cable gland
Temperature range
Degree of protection
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection By 10 A cartridge fuse type gG (gl)
Setting range of upper limit (PH)
Body dimensions, W x D x H
– 20...+ 60°C
IP66
0.7…10 bar
35 x 75 x 113 mm
1.3…20 bar 3.5…35 bar
Oil, water, air, up to +70°C Fluids controlled
Possible differential
(subtract from PH to give PB)
Min. at low setting
Min. at high setting
Max. at high setting
0.57 bar
0.85 bar
7.5 bar
1 bar
1.6 bar
11 bar
1.7 bar
2.55 bar
20 bar
1 CO single pole, snap action contact XMLB010A2S12EX XMLB020A2S12EX XMLB035A2S12EX
Other characteristics: please refer to the “Detection for OsiSense automation solutions” catalog.
74
Other versions: please consult our Customer Care Centre.
Type
Size
Conformity
Vacuum switches and vacu-pressure switches with setting scale
- 1 bar - 0.2 bar
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
5 bar
Zone D (dust)
EC type examination certificate number / marking
Fluid connection
Electrical connection
21 - 22
INERIS 04ATEX0058 / D-Ex tb C T85°C Db IP66
1/4” BSP female
Screw terminals, 1 entry fitted with ISO M20 cable gland
Temperature range
Degree of protection
Setting range of upper limit (PH)
Body dimensions, W x D x H
– 20...+ 60°C
IP66
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection By 10 A cartridge fuse type gG (gl)
–0.14…–1 bar
55 x 77.5 x 158 mm
–0.02…–0.2 bar
150 x 155.5 x 145 mm
–0.5…5 bar
113 x 35 x 75 mm
Oil, water, air, up to +70°C Oil, air, up to +160°C Oil, water, air, up to +70°C Fluids controlled
Possible differential
(subtract from PH to give PB) (1)
Min. at low setting
Min. at high setting
Max. at high setting
0.13 bar
0.13 bar
0.8 bar
0.018 bar
0.018 bar
0.18 bar
0.5 bar
0.5 bar
6 bar
1 CO single pole, snap action contact XMLBM02V2S12EX
(1) For XMLBM02V2S12EX and XMLBM03R2S12EX vacuum switches add to PB to give PH
XMLBM03R2S12EX XMLBM05A2S12EX
Pressure switches with setting scale
0.05 bar 0.35 bar
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0058 / D-Ex tb C T85°C Db IP66
1/4” BSP female
1 bar
Screw terminals, 1 entry fitted with ISO M20 cable gland
– 20...+ 60°C
IP66
AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
By 10 A cartridge fuse type gG (gl)
0.026…0.05 bar
200 x 204 x 145 mm
Oil, air, up to +160°C
0.045…0.35 bar
110 x 110 x 162 mm
0.05…1 bar
0.0014 bar
0.004 bar
0.042 bar
0.05 bar
0.04 bar
0.06 bar
0.04 bar 0.3 bar 0.75 bar
XMLBL05R2S12EX XMLBL35R2S12EX XMLB001R2S12EX
(1) For XMLBM02V2S12EX and XMLBM03R2S12EX vacuum switches add to PB to give PH
2.5 bar 4 bar
0.3…2.5 bar
55 x 77.5 x 158 mm
Oil, water, air, up to +70°C
0.16 bar
0.21 bar
1.75 bar
XMLB002A2S12EX
0.25…4 bar
55 x 77.5 x 158 mm
0.2 bar
0.25 bar
2.4 bar
XMLB004A2S12EX
Type
Size
Conformity
Pressure switches with setting scale
10 bar 20 bar
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
35 bar
Zone D (dust)
EC type examination certificate number / marking
Fluid connection
Electrical connection
21 - 22
INERIS 04ATEX0058 / D-Ex tb C T85°C Db IP66
1/4” BSP female
Screw terminals, 1 entry fitted with ISO M20 cable gland
Temperature range
Degree of protection
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
Short-circuit protection By 10 A cartridge fuse type gG (gl)
Setting range of upper limit (PH)
Body dimensions, W x D x H
– 20...+ 60°C
IP66
0.7…10 bar
35 x 75 x 113 mm
1.3…20 bar 3.5…35 bar
Oil, water, air, up to +70°C Fluids controlled
Possible differential
(subtract from PH to give PB)
Min. at low setting
Min. at high setting
Max. at high setting
0.57 bar
0.85 bar
7.5 bar
1 bar
1.6 bar
11 bar
1.7 bar
2.55 bar
20 bar
1 CO single pole, snap action contact XMLB010A2S12EX XMLB020A2S12EX XMLB035A2S12EX
Other characteristics: please refer to the “Detection for OsiSense automation solutions” catalog.
Pressure switches with setting scale
70 bar 160 bar
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0058 / D-Ex tb C T85°C Db IP66
1/4” BSP female
300 bar
Screw terminals, 1 entry fitted with ISO M20 cable gland
– 20...+ 60°C
IP66
AC15; B300 (Ue = 240 V, Ie = 1.5 A; Ue = 120 V, Ie = 3 A)/DC13; R300 (Ue = 250 V, Ie = 0.1 A)
By 10 A cartridge fuse type gG (gl)
7…70 bar
35 x 75 x 113 mm
Oil, up to +160°C
10…160 bar 22…300 bar
4.7 bar
8.8 bar
50 bar
XMLB070D2S12EX
9.3 bar
20.8 bar
100 bar
XMLB160D2S12EX
19.4 bar
37 bar
200 bar
XMLB300D2S12EX
500 bar
30…500 bar
23 bar
52.6 bar
300 bar
XMLB500D2S12EX
Other versions: please consult our Customer Care Centre.
75
Inductive proximity sensors
Discrete, metal case
OsiSense XS
Sensor type
Conformity
Zone D (dust)
EC type examination certificate number / marking
Nominal sensing distance Sn
Operating zone
Temperature range
Degree of protection (conforming to IEC 60529)
Connection
Dimensions
Supply voltage (including ripple)
Maximum switching capacity
Overload and short-circuit protection
LED output state indicator
Voltage drop, closed state, at I nominal
Switching frequency
References NO function
NC function
M12 M18
3-wire DC PNP, flush mountable in metal
Directive ATEX 94/9/EC, EN 60079-0, EN 60079-31
21 - 22
INERIS 04ATEX0022X / D-Ex tb C T90°C Db IP68
4 mm 8 mm
0...3.2 mm
– 20...+ 60°C
0...6.4 mm
IP68
Pre-cabled, PvR, L = 10 m
M12 x 50 mm
10...58 VDC
200 mA
Yes
Yes
≤ 2 V
2500 Hz
XS612B1PAL10EX
XS612B1PBL10EX
M18 x 60 mm
1000 Hz
XS618B1PAL10EX
XS618B1PBL10EX
M30
15 mm
0...12 mm
M30 x 60 mm
500 Hz
XS630B1PAL10EX
XS630B1PBL10EX
Analog, metal case
Sensor type
Conformity
Zone D (dust)
EC type examination certificate number / marking
Nominal sensing distance Sn
Operating zone
Temperature range
Degree of protection (conforming to IEC 60529)
Connection
Dimensions
Supply voltage (including ripple)
Linearity error
Operating frequency
References 4…20 mA output
M12 M18
Analogue, 2-wire AC/DC, flush mountable in metal
Directive ATEX 94/9/EC, EN 60079-0, EN 60079-31
21 - 22
INERIS 04ATEX0022X / D-Ex tb C T90°C Db IP67
2 mm 5 mm
0.2...2 mm
– 20...+ 60°C
0.5…5 mm
IP67
Pre-cabled, PvR, L = 2 m
M12 x 50 mm
10…38 VAC/DC
10%
1500 Hz
XS1M12AB120EX
M18 x 60 mm
500 Hz
XS1M18AB120EX
M30
10 mm
1...10 mm
M30 x 60 mm
300 Hz
XS1M30AB120EX
Other characteristics: please refer to the “Detection for OsiSense automation solutions” catalog
76
Other versions: please consult our Customer Care Centre.
Inductive Proximity sensors
Rotation monitoring, metal case
Sensor type
Conformity
Zone D (dust)
EC type examination certificate number / marking
Nominal sensing distance Sn
Operating zone
Temperature range
Degree of protection (conforming to IEC 60529)
Connection
Dimensions
Supply voltage (including ripple)
Maximum switching capacity
Overload and short-circuit protection
LED output state indicator
Voltage drop, closed state, at I nominal
Version
Maximum speed of passing object
Adjustable frequency range
References NC function
M30
3-wire DC PNP, flush mountable in metal
Directive ATEX 94/9/EC, EN 60079-0, EN 60079-31
21 - 22
INERIS 04ATEX0022X / D-Ex tb C T90°C Db IP67
10 mm
0…8 mm
– 20...+ 60°C
IP67
Pre-cabled, PvR, L = 2 m
M30 x 81 mm
10...58 VDC
200 mA
Yes
Yes
≤ 2 V
Slow
6000 impulses/minute
6…150 impulses/minute
XSAV11373EX
Fast
48,000 impulses/minute
120…3000 impulses/minute
XSAV12373EX
Other versions: please consult our Customer Care Centre.
77
Namur inductive sensors
Metal or plastic case
OsiSense XS
Sensor type
Case type
Conformity
Zone D (dust)
EC type examination certificate number / marking
Nominal sensing distance Sn
Operating zone
Temperature range
Degree of protection (conforming to IEC 60529)
Connection
Dimensions
Supply voltage (including ripple)
Maximum switching capacity
Overload and short-circuit protection
Residual current, open state
Switching frequency
References NC function
M5 M8 M12 M18 M30
2-wire DC, flush mountable in metal
Metal Plastic
Directive ATEX 94/9/EC, EN/IEC 60079-0,EN/IEC 60079-11
20 (to be used in conjunction with intrinsically safe enclosures, see page 5)
INERIS 04ATEX0016X / D-Ex ia C T85°C Da IP66/67
0.8 mm 1.5 mm 2 mm 5 mm
0…0.6 mm
– 20...+ 60°C
M5 x 30 mm
7…12 VDC
0…0.8 mm
IP67
Pre-cabled, PvR, L = 2 m
M8 x 26.5 mm
0…1.2 mm 0…1.6 mm 0…4 mm
M12 x 38.5 mm M18 x 41 mm
10 mm
0…8 mm
M30 x 43.5 mm
≤ 1 mA
Yes
≥ 3 mA
1500 Hz 1000 Hz 800 Hz 500 Hz 300 Hz
XSMN08122EX XSAN01122EX XSPN01122EX XSPN02122EX XSPN05122EX XSPN10122EX
Plastic case
Sensor type
Case type
Conformity
Zone D (dust)
EC type examination certificate number / marking
Nominal sensing distance Sn
Operating zone
Temperature range
Degree of protection (conforming to IEC 60529)
Connection
Dimensions
Supply voltage (including ripple)
Maximum switching capacity
Overload and short-circuit protection
LED output state indicator
Residual current, open state
Switching frequency
References
(1) Flush mountable in metal
NC function
M12 M18 M30
2-wire DC, non flush mountable in metal
Plastic
Directive ATEX 94/9/EC, EN/IEC 60079-0,EN/IEC 60079-11
20
INERIS 04ATEX0016X / D-Ex ia C T85°C Da IP66/67
4 mm 8 mm 15 mm
0…3.2 mm
– 20...+ 60°C
IP67
Pre-cabled, PvR, L = 2 m
M12 x 38.5 mm
7…12 VDC
≤ 1 mA
Yes
Yes
≥ 3 mA
400 Hz
XSPN04122EX
Other characteristics: please refer to the “Detection for OsiSense automation solutions” catalog
78
0…6.4 mm
M18 x 41 mm
300 Hz
XSPN08122EX
0…12 mm
M30 x 43.5 mm
200 Hz
XSPN15122EX
Forme D
40 mm
0…32 mm
100 x 80 x 40 mm
25 Hz
XSDN401229EX
Other versions: please consult our Customer Care Centre.
Intrinsically safe module
Processing module
Module type
Conformity
Zone D (dust)
EC type examination certificate number / marking
Zone 20 Number of input channels
Number of output channels
Type of output channel, load excitation
Outside zone Number of recopying channels
Switching voltage
Switching current
Temperature range
Connection
Mounting
Dimensions, W x D x H
Supply voltage (including ripple)
Consumption
References
Discrete
Inputs Relay inputs/outputs
Directive ATEX 94/9/EC, EN 60079-0, EN 60079-11, EN 61241-11
Mounted outside zone (to be used in conjunction with products for zone 20, 21 or 22)
LCIE 00ATEX6034X / GD-[Ex ia Ga] C / [Ex ia Da] C
2 4 2 2
–
–
–
2
1 1
Low consumption solenoid valve, < 7 mA High consumption solenoid valve, < 40 mA with hysteresis –
2 with hysteresis
2 4
5…230 VAC; 5…24 VDC
10 mA…0.5 A (AC); 10 mA…0.5 A, L/R 48 ms (DC)
– 20...+ 60°C
Removable screw terminal blocks
On 35 mm DIN rail
29.5 x 120 x 90 mm
24 VDC (0.95…1.1 Un)
5 W
NY320N2RB1 NY340N4RB1 NY321L2RB1 NY321L1RB1 NY321H2RB1 NY321H1RB1
Module type
Conformity
Zone D (dust)
Discrete
Load excitation outputs
Directive ATEX 94/9/EC, EN 60079-0, EN 60079-11, EN 61241-11
EC type examination certificate number / marking
Zone 20 Number of load excitation channels 2
Mounted outside zone (to be used in conjunction with products for zone 20, 21 or 22)
LCIE 00ATEX6034X / GD-[Ex ia Ga] C / [Ex ia Da] C
4
Maximum current < 7 mA < 40 mA < 7 mA < 40 mA
Outside zone Control voltage
Control current
Temperature range
Connection
Mounting
Dimensions, W x D x H
Supply voltage (including ripple)
Consumption
References
24 VDC ± 10%
State 1 = 6.5 < I < 9 mA and 21.6 < U < 26.4 V; State 0 = I ≤ 0.4 mA and U ≤ 1.2 V
– 20...+ 60°C
Removable screw terminal blocks
On 35 mm DIN rail
29.5 x 120 x 90 mm
24 VDC (0.95…1.1 Un)
5 W
NY302L0NB1 NY302H0NB1 NY304L0NB1 NY304H0NB1
Other versions: please consult our Customer Care Centre.
79
Safety switches and actuators
Preventa
3-pole contact
Slow break
1NC+2NO
ISO entry
(to EN 50262)
3-pole contact
Slow break
2NC+1NO
Position of the contact when the actuator is in the head of the switch
Metal switches type
With head
Conformity
XCSA/B/C, 1 entry fitted with ISO M20 cable gland
Without locking Interlocking, unlocking by button Interlocking, unlocking by key lock
Directive ATEX 94/9/CE, EN/IEC 60079-0, EN/IEC 60079-31
Zone D (dust)
EC type examination certificate number / marking
Maximum safety level (1)
Actuation speed (min → max)
Short-circuit protection
Reliability data B10d
Complete switch 1NC+2NO
2NC+1NO
21 - 22
INERIS 04ATEX0014X / D-Ex tb C T85°C Db IP67
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
0,1 m/s → 0,5 m/s
Degree of protection IP 67
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC 15, A 300 / DC 13, Q 300
Temperature range
Dimensions (body+head) W x D x H
-20…+60°C
40 x 44 x 113.5 mm
By 10 A cartridge fuse type gG (gl)
52 x 44 x 113.5 mm 52 x 44 x 113.5 mm
5 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
XCSA502EX
XCSA702EX
XCSB502EX
XCSB702EX
XCSC502EX
XCSC702EX
Accessories
For safety switches XCSA/B/C
References
Straight actuator
Actuators
XCSZ01
Wide actuator
XCSZ02
Coded magnetic
Pivoting actuator
XCSZ03
Door lock
XCSZ05
Contact
1NC+1NO staggered
Contact
2NC staggered
Contact states shown are whilst the magnet is in front of the switch
Plastic switches type XCSDM coded magnetic, Pre-cabled, L = 2 m
Rectangular without LED
Conformity
Zone D (dust)
EC type examination certificate number / marking
Maximum safety level (1)
Directive Atex 94/9/CE, EN 60079-0, EN 60079-18, EN 60079-31, EN 1088, EN/ISO 13849-1
0-1-2/20-21-22*(according to protection mode, mD or ia).
INERIS 04ATEX0036 / D-Ex ia B Da T135°C / D-Ex tb C T135°C Db IP67
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
Switches for actuation
Degree of protection
Type of contact REED
Rated operational characteristics (conforming to EN IEC 60947-5-1) Ue = 24 VDC, Ie = 100 mA
Temperature range
Dimensions W x D x H
Face to face, face to side, side to side
IP 66 + IP 67
-20…+60°C
16 x 7 x 51 mm
Sao = 5 / Sar = 15 Operating zone
Short-circuit protection
Reliability data B10d
Switch with coded magnet 1NC+1NO staggered
2NC staggered
(1) Using an appropriate and correctly connected control system.
By 10 A cartridge fuse type gG (gl)
50 000 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
XCSDMC5902EX
XCSDMC7902EX
Other versions: please consult our Customer Care Centre.
80
Emergency stops
Emergency stop rope pull switches
Preventa
For operating cable up to 70 m long
Conformity
Zone D (dust)
EC type examination certificate number / marking
Maximum safety level (1)
Mechanical durability (millions of operating cycles)
Latching, without indicator light
Temperature range
Degree of protection
– 20...+ 60°C
IP65
Connection 2 entries fitted with blanking plugs, 1 entry fitted with ISO M20 cable gland
Rated operational characteristics (conforming to EN IEC 60947-5-1) AC15; A300 (Ue = 240 V, Ie = 3A)/DC13; Q300 (Ue = 250 V, Ie = 0.27 A)
Short-circuit protection
Dimensions, W x D x H
By 10 A cartridge fuse type gG (gl)
229 x 82 x 142 mm 229 x 105 x 142 mm
Reset
Operating cable length
Operating cable anchoring point
Reliability data B10d
References NC+NO slow break
NC+NC slow break
(1) Using an appropriate and correctly connected control system.
Directive ATEX 94/9/EC, EN/IEC 60079-0, EN/IEC 60079-31
21 - 22
INERIS 04ATEX0015 / D-Ex tb C T85°C Db IP65
PL=e, category 4 conforming to EN/ISO 13849-1 and SIL CL3 conforming to EN/IEC 62061
0.01
By booted pushbutton
≤ 70 m
To left
By key release pushbutton (key n° 421)
50 000 (value given for a service life of 20 years, limited by mechanical or contact wear)
XY2CE2A250EX
XY2CE2A270EX
To right
XY2CE1A250EX
XY2CE1A270EX
≤ 70 m
To left
XY2CE2A450EX
XY2CE2A470EX
To right
XY2CE1A450EX
XY2CE1A470EX
Other characteristics: please refer to the “Machine safety” catalog
Other versions: please consult our Customer Care Centre.
81
Schneider Electric Industries SAS
Head Office
35, rue Joseph Monier - CS 30323
F92500 Rueil-Malmaison Cedex
France www.tesensors.com
ART. 805664
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Design : IGS-CP
Photos : Schneider Electric
Print :
V10
다운로드
광고