APPLICATION-NOTE
OBID
®
Firmware Update Tool
Version 6.08.00 and higher
final public (B)
2011-11-04
N30300-8e-ID-B.doc
OBID i-scan
®
© Copyright 2004 -2011 by FEIG ELECTRONIC GmbH
Lange Straße 4
Note
OBID
®
Firmware Update Tool
Tel.: +49 6471 3109-0 http://www.feig.de
Copying of this document, and giving it to others and the use or communication of the contents thereof are forbidden without express authority. Offenders are liable to the payment of damages. All rights are reserved in the event of the grant of a patent or the registration of a utility model or design.
Indications made in this manual may be changed without previous notice. With the edition of this manual, all previous editions become void.
Composition of the information in this manual has been done to the best of our knowledge. FEIG ELECTRONIC
GmbH does not guarantee the correctness and completeness of the details given in this manual and may not be held liable for damages ensuing from incorrect or incomplete information. Since, despite all our efforts, errors may not be completely avoided, we are always grateful for your useful tips.
The installation instructions given in this manual are based on advantageous boundary conditions. FEIG
ELECTRONIC GmbH does not give any guarantee promise for perfect function of an OBID®-system in cross surroundings.
FEIG ELECTRONIC GmbH assumes no responsibility for the use of any information contained in this manual and makes no representation that they free of patent infringement. FEIG ELECTRONIC GmbH does not convey any license under its patent rights nor the rights of others.
OBID i-scan
®
is a registered trademark of FEIG ELECTRONIC GmbH
Windows
®
is a registered trademark of Microsoft Corporation
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit. ( http://www.openssl.org/ )
Copyright (c) 1998-2008 The OpenSSL Project. All rights reserved.
This product includes software written by Tim Hudson ([email protected])
Copyright (C) 1995-1998 Eric Young ([email protected]). All rights reserved.
System requirements:
• Personal computer with x86-CPU with at least 1GHz
• Windows® XP, Windows® Vista, Windows 7® (32/64 Bit)
• Windows®-compatible VGA graphics card with (1024 x 768 recommended)
• Windows®-compatible mouse
• Hard disk with at least 20MB free space
FEIG ELECTRONIC GmbH Page 2 of 2 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
Contents
1. Licensing Agreement Concerning Use of Software “OBID
Firmware Update Tool” ................. 4
FEIG ELECTRONIC GmbH Page 3 of 3 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
1. Licensing Agreement Concerning Use of Software “OBID
®
Firmware Update Tool”
This is an agreement between you and FEIG ELECTRONIC GmbH (hereafter "FEIG") for use of provided
Software and all there parts (application program, libraries, etc.) and the included documentation, hereafter called licensing material. By installing and using the licensing material you agree to all terms and conditions of this agreement without exception and without limitation. If you are not or not completely in agreement with the terms and conditions, you may not install the licensing material or use it in any way.
§1 Object and scope of the agreement
1. FEIG grants you the non exclusive right to install the licensing material provided and to use it under the following conditions.
2. You may install all components of the licensing material on a hard disk or an other storage medium. The installation and use may also be done on a network fileserver. You may create backup copies of the licensing material. Further you are allowed to install and use the licensing material in-house unlimited.
3. The licensing material may only be used in conjunction with devices which are developed and / or produced by
FEIG.
4. This license material can depend on third-party software. In case of the use of this third-party software the
listed license agreements in chapter Third-party Licensing agreements have to be applied.
§2 Protection of the licensing material
1. The licensed material is the intellectual property of FEIG and its suppliers. It is protected in accordance with copyright, international agreements and relevant national statutes where it is used. The structure, organization and code of the software are a valuable business secret and confidential information of FEIG and its suppliers.
2. You agree not to change, modify, adapt, translate, reverse engineer, decompile, disassemble or otherwise attempt to discover the source code of the licensed material.
3. To the extent that FEIG has applied protection marks, such as copyright marks and other legal restrictions in the licensing material, you agree to keep these unchanged and to use them unchanged in all complete or partial copies which you make.
4. The publication and transmission to third parties of licensed material prohibited as long as no explicit agreement to the contrary has been established between you and FEIG.
FEIG ELECTRONIC GmbH Page 4 of 4 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
§3 Warranty and liability limitations
1. You agree with FEIG that it is not possible to develop electronic data processing programs such that they are without defect for all application conditions. FEIG calls explicit attention to the fact that the installation of a new program may affect already existing software, including software which does not run simultaneous with the new software. In no event will FEIG be liable to you for any consequential, incidental or special damages, including any lost profits or lost savings. If you want to be sure that no already installed program will be affected, you may not install the licensed material.
2. FEIG calls explicit attention to the fact that the use of the licensed material may result irreversible settings and adjustments to devices which may in turn destroy or otherwise make them unusable. FEIG assumes no liability for such actions whether knowingly or unknowingly.
3. FEIG provides the software "as is“ and without any warranty. FEIG cannot guarantee the performance or the results you obtain from using the licensed material. FEIG assumes no liability or guarantee that the protection rights of third parties are not violated, nor that the software is suitable for a particular purpose.
4. FEIG call explicit attention the licensed material is not designed with components and testing for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human.
To avoid damage, injury, or death, the user or application designer must take reasonably prudent steps to protect against system failures.
§4 final clause
1. This Agreement contains the complete licensing terms and conditions and supersedes any prior agreements and terms. Changes and additions must be made in writing.
2. If any provision in this agreement is declared to be void, or if for any reason is declared to be invalid or of no effect, the remaining provisions shall be in no manner affected thereby but shall remain in full force and effect.
Both parties agree to replace the invalid provision with one which comes closest to its original intention.
3. This agreement is subject to the laws of the Federal Republic of Germany. Place of jurisdiction is
Frankfurt a. M.
Please direct any questions pertaining to this agreement to:
FEIG ELECTRONIC GmbH
Lange Strasse 4,
D-35781 Weilburg-Waldhausen
- Germany -
Fon: +49 6471 / 3109-0
Fax: +49 6471 / 3109-99 e-mail: [email protected]
http://www.feig.de
FEIG ELECTRONIC GmbH Page 5 of 5 N30300-8e-ID-B.doc
OBID i-scan
®
Third-party Licensing agreements
OBID
®
Firmware Update Tool
Licensing agreement of openSSL organization
The following license issues are to be applied in the case that encrypted data transmission is used.
LICENSE ISSUES
==============
The OpenSSL toolkit stays under a dual license, i.e. both the conditions of the OpenSSL License and the original SSLeay license apply to the toolkit. See below for the actual license texts. Actually both licenses are BSD-style Open Source licenses. In case of any license issues related to OpenSSL please contact [email protected].
OpenSSL License
---------------
====================================================================
Copyright (c) 1998-2008 The OpenSSL Project. All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
3. All advertising materials mentioning features or use of this software must display the following acknowledgment:
"This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit.
(http://www.openssl.org/)"
4. The names "OpenSSL Toolkit" and "OpenSSL Project" must not be used to endorse or promote products derived from this software without prior written permission. For written permission, please contact [email protected].
5. Products derived from this software may not be called "OpenSSL" nor may "OpenSSL" appear in their names without prior written permission of the OpenSSL Project.
6. Redistributions of any form whatsoever must retain the following acknowledgment:
"This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit
(http://www.openssl.org/)"
THIS SOFTWARE IS PROVIDED BY THE OpenSSL PROJECT ``AS IS'' AND ANY EXPRESSED OR IMPLIED WARRANTIES,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE OpenSSL PROJECT OR ITS CONTRIBUTORS BE LIABLE FOR ANY
DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED
TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR
TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
====================================================================
This product includes cryptographic software written by Eric Young ([email protected]). This product includes software written by Tim Hudson ([email protected]).
FEIG ELECTRONIC GmbH Page 6 of 6 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
Original SSLeay License
-----------------------
Copyright (C) 1995-1998 Eric Young ( [email protected]
) All rights reserved.
This package is an SSL implementation written by Eric Young ([email protected]).
The implementation was written so as to conform with Netscapes SSL.
This library is free for commercial and non-commercial use as long as the following conditions are aheared to. The following conditions apply to all code found in this distribution, be it the RC4, RSA, lhash, DES, etc., code; not just the SSL code. The SSL documentation included with this distribution is covered by the same copyright terms except that the holder is Tim Hudson ([email protected]).
Copyright remains Eric Young's, and as such any Copyright notices in the code are not to be removed.
If this package is used in a product, Eric Young should be given attribution as the author of the parts of the library used.
This can be in the form of a textual message at program startup or in documentation (online or textual) provided with the package.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the copyright notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
3. All advertising materials mentioning features or use of this software must display the following acknowledgement:
"This product includes cryptographic software written by Eric Young ([email protected])"
The word 'cryptographic' can be left out if the rouines from the library being used are not cryptographic related :-).
4. If you include any Windows specific code (or a derivative thereof) from the apps directory
(application code) you must include an acknowledgement:
"This product includes software written by Tim Hudson ([email protected])"
THIS SOFTWARE IS PROVIDED BY ERIC YOUNG ``AS IS'' AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED
AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGE.
The licence and distribution terms for any publically available version or derivative of this code cannot be changed. i.e. this code cannot simply be copied and put under another distribution licence
[including the GNU Public Licence.]
FEIG ELECTRONIC GmbH Page 7 of 7 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
2. Safety Instructions / Warning - Read before start-up!
• The device may only be used for the intended purpose designed by the manufacturer.
• The operation manual should be conveniently kept available at all times for each user.
• Unauthorized changes and the use of spare parts and additional devices which have not been sold or recommended by the manufacturer may cause fire, electric shocks or injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
• The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device. The manufacturer shall not be held legally responsible for inaccuracies, errors, or omissions in the manual or automatically set parameters for a device or for an incorrect application of a device.
• Repairs may only be executed by the manufacturer.
• Installation, operation, and maintenance procedures should only be carried out by qualified personnel.
• Use of the device and its installation must be in accordance with national legal requirements and local electrical codes.
• When working on devices the valid safety regulations must be observed.
FEIG ELECTRONIC GmbH Page 8 of 8 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
3. Introduction
This program tool can be used to perform a firmware update by the OBID i-scan® reader
• ID
ISC.M02.M8-B
• ID
ISC.MR102
ISC.MR200
• ID ISC.LR2000 / LRM2000
ISC.LR2500-A
ISC.LR2500-B
• ID
ISC.PRH102
ISC.PRHD102
• ID
• ID ISC.MRU200 / MRU200i (Please read first the application note: N80060-0e-ID-A.pdf)
• ID ISC.LRU2000 / LRMU2000 / LRU2000i
• ID ISC.LRU3000 / LRU3500 the
OBID®
classic-pro reader:
CPR.02
CPR.M02
• ID
CPR30.xx
CPR40.xx
• ID
CPR50.xx
CPR52.xx
MAX50.xx the classic reader (125kHz):
RW/RWA40.30 the automatic antenna tuner:
• ID ISC.DAT (Please read first the application note: N50801-1e-ID-B.pdf) the UHF antenna multiplexer:
•
ID ISC.ANT.UMUX (Please read first the application note: N80301-0e-ID-B.pdf) the Gate People counter:
• ID
ISC.ANT1700/740-GPC
FEIG ELECTRONIC GmbH Page 9 of 9 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
Note:
• This new OBIDFirmwareUpdateTool 6.0x support’s only the new firmware files with the
•
extension “.xml”!
This new OBIDFirmwareUpdateTool 6.0x support’s also the automatic installation of firmware package files which can contain more than one firmware parts (e.g. RFC, ACC,
FPGA).
FEIG ELECTRONIC GmbH Page 10 of 10 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
3.1. Known Issues
The following knows issues will be probably solved with one of the next software version.
Reader ISSUE
ID ISC.LR/LRU2000
An update via WLAN interface will close the WLAN connection. The reader must be switched off and on manually.
An update via WLAN is not recommended.
ID ISC.LRU1000
The update of the old ID ISC.LRU1000 reader must be done with
OBIDFirmwareUpdateTool 5.01.05.
3.2.
Revision History of OBIDFirmwareUpdateTool
Revision Date Description
Modification for ID ISC.LRU3000/3500: Update process is changed for
ACC to support large partitions
6.08 04.11.11
Support of ID ISC.MRU102
Support of People Counter Update via reader ID ISC.LR2500-A
6.06 21.03.11 Support of ID ISC.MR102-PoE and ID ISC.LR2500-A
Support of ID ISC.MR102-A/ -B/ -U, ID ISC.LR2500-B,
6.05 31.01.11
ID CPR52.xx and ID CPR30.xx
6.04 02.09.10 Support of ID CPR.44.0x-4SCUSB-B
Support of People Counter ID ISC.ANT1690/600-GPC and
ID ISC.ANT1700/740-GPC.
Improved update of FPGA controller if firmware in reader is missing or wrong
Please note:
• For the Update it is recommended to configure the ISOHost mode in the reader.
• Close all other running Windows
®
programs onto the PC.
• Before an update on the LAN interface is started, the Windows Firewall should be switched
off temporary.
• Update over WLAN is not recommended.
FEIG ELECTRONIC GmbH Page 11 of 11 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
• Avoid any converters like USB to RS232 or RS232 to TCP/IP if it is possible.
• For RS232/485 the maximum Baudrate should be 38400baud.
• It is not recommended to use an USB-Hub for an update over USB. It is strongly
recommended to connect the reader directly with an USB port at the PC.
• Do not interrupt the power supply until the update process has not been finished.
• If existing we recommend to use the TCP/IP interface, except of the ID ISC.MR200 / MRU200.
• After the successful installation of the new firmware the current version of the ISOStart /
CPRStart demo program should be used to test the reader. The current version can be downloaded from the download area of FEIG ELECTRONIC GmbH.
•
If the update was not successful and the old firmware has been already deleted please call the customer support of FEIG ELECTRONIC GmbH.
FEIG ELECTRONIC GmbH Page 12 of 12 N30300-8e-ID-B.doc
OBID i-scan
®
4. The update step by step
4.1. Detection and selection of the reader
1. Close any other running Windows programs onto your PC.
2. Start the program by double click on OBIDFirmwareUpdateTool.exe:
OBID
®
Firmware Update Tool
3. By using the RS232 / 485 interface enable the COM-Port and select the used COM-Port and Bus
Address. If a RS232 to RS232TTL converter is used, click on the “More...” button and read the following chapters
4.1.2. Using RS232 to RS232TTL converter
.
4. USB-interface: enable the USB Interface connection. It is strongly recommended to connect the reader directly with an USB port at the PC. The use of an USB-Hub can cause communication problems with the result of a damaged reader firmware.
5. For TCP/IP connection the TCP/IP must be enabled and the IP-Address and Port number must be set.
6. Click on the “Detect”-button. The connected reader must be displayed in the list:
7. Check the “Log Options” button and read chapter:
4.1.1. Additional Options for Logging
8. Click on the “Next”-button.
FEIG ELECTRONIC GmbH Page 13 of 13 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
4.1.1. Additional Options for Logging
A logging option offers the possibility to store a log file while the update process runs.
Within the Option window you have the chance to select the amount of log data.
The most detailed information’s are stored with the option “very high amount of log data”. This offers
FEIG ELECTRONIC GmbH the possibility to analyze the process in the case if a firmware update fails for any reason.
In the case of an error three log files will be stored in the folder of the OBIDFirmwareUpdateTool.
Example:
Please send these files to the OBID Customer support ( [email protected]
) for an analyze.
If the update finished without any problem the files will be deleted automatically.
FEIG ELECTRONIC GmbH Page 14 of 14 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
4.1.2. Using RS232 to RS232TTL converter
The OBID i-scan® reader type ID ISC.ISC.M02 and the OBID® classic-pro reader types
ID CPR.M02 and ID CPR.03 need a RS232 to RS232TTL (5V) converter:
RS232-TTL Converter
1962.000.00
Model 232LPTTL
B&B Electronic Ltd.
The OBID i-scan® reader types ID ISC.CPR40.0x-CD 3.3 will need a RS232 to RS232TTL
(3,3V) converter.
RS232-TTL Converter
xxxx.000.00
Model 232LPTTL33
B&B Electronic Ltd.
By using a notebook it is sometimes necessary to enable the DTR and RTS signals to provide the converter with sufficient power. To do this you have to mark the DTR and RTS checkbox:
Click on “OK”.
FEIG ELECTRONIC GmbH Page 15 of 15 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
4.2. Selection of the new firmware
1. Click on the “Select Path...”-button and select the correct “ *.xml”-file for the connected reader type. You can use separate files for each controller like “RFC, ACC, FPGA” or you can use a firmware package which includes all firmware files for all controllers in one file.
Please note that you have to use the new xml-file specification.
You can download the current version from our download area.
FEIG ELECTRONIC GmbH Page 16 of 16 N30300-8e-ID-B.doc
OBID i-scan
®
2. Choose the path were the new firmware is located.
OBID
®
Firmware Update Tool
3. The correct firmware in the list must be marked:
4.
Click on the “Next”-button.
FEIG ELECTRONIC GmbH Page 17 of 17 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
4.3. Verifying of the data
1. Check the information in the next window. If all data are OK click on the “Next”-button.
If you have a firmware package selected all included firmware files (FPGA, RFC or ACC) will be installed one after the other automatically.
4.4. Start update process
1. Click the “Start Update”-button. The progress bar indicates the progress of the update.
Do not interrupt this process!
Do not disconnect the power cable or the data cable!
While the update is running you cannot finish the program manually!
Please wait!
Do not close the program by using the Windows® Task Manager!
FEIG ELECTRONIC GmbH Page 18 of 18 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
FEIG ELECTRONIC GmbH Page 19 of 19 N30300-8e-ID-B.doc
OBID i-scan
®
OBID
®
Firmware Update Tool
4.4.1. Finishing Update
If a significant firmware version step has taken place all configuration parameters will be set to factory default values. Afterwards the reader needs to be rebooted manually. If this is necessary the Update
Tool will offer you the possibility to do this by software command.
After receiving the message “Ready” the tool can be closed by clicking on the “Finish”-button.
Now you can finish the OBID® Firmware Update Tool or you can click on “Next Reader” and can perform a second update on the same or a second reader.
After the successful installation of the new firmware the current version of the ISOStart demo program should be used to test the reader. The current ISOStart version can be downloaded
from the download area of FEIG ELECTRONIC GmbH.
FEIG ELECTRONIC GmbH Page 20 of 20 N30300-8e-ID-B.doc
OBID i-scan
®
5. If the update failed
OBID
®
Firmware Update Tool
5.1. Restart Update
If the update process does not come to the end with the message “Ready”, please do not perform a
CPU-Reset or switch OFF and On the reader.
The program gives you the possibility to run the update process a second time.
After receiving a message like it is shown in the picture below please Click the “Yes”-button and try it again.
5.2. Update using the hardware flash loader
If the update failed again you can perform an update using a hardware flash loader as it is described in the firmware update application note of the corresponding reader.
This is only possible by the reader:
• ID
ISC.M02
• ID CPR.M02
(see application note: N21101-xy-ID-B.pdf)
(See application note: N30201-xy-ID-B.pdf)
• ID CPR.02
• ID ISC.MRU200
(See application note: N30201-xy-ID-B.pdf)
(See application note: N80060-0e-ID-A.pdf)
Other reader types have to be send to FEIG ELECTRONIC GmbH for repair.