Owner’s Manual
Legacy
®
Basic Acoustical Shell
C
ONTENTS
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Set Up and Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Important User Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Manufacturer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Terminology. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Storing the Shells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Moving the Shells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Arranging the Shells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Raising the Shell. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Lowering the Shell . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Replacement Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mechanical Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Panel Repair. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Note: Please read and understand this Owner’s Manual before working with or using the
Legacy
®
Basic Acoustical Shell.
Note: If you need additional information about the Legacy
Wenger Corporation using the information below.
®
Basic Acoustical Shell, contact the
©Wenger Corporation 2012 Printed in USA 07/12 Part #186H597-02
Wenger Corporation, 555 Park Drive, P.O. Box 448, Owatonna, Minnesota 55060-0448
Questions? Call.....USA: 1-800-4WENGER (493-6437) • Worldwide: 1-507-455-4100 • www.wengercorp.com
S
AFETY
P
RECAUTIONS
G
ENERAL
Throughout this manual you will find CAUTIONS and WARNINGS which are defined as follows.
•
WARNING means that failure to follow the instruction may result in serious injury or death.
•
CAUTION means that failure to follow the instruction may result in serious injury or damage to property.
Read all of these safety instructions before setting up the Legacy Basic Acoustical Shell components.
S
ET
U
P AND
U
SAGE
!
CAUTION
Make sure that anyone operating the Legacy Basic Acoustical
Shell has read and understands this manual.
!
CAUTION
Always observe and comply with the Warnings and Cautions posted on the system equipment.
!
CAUTION
Failure to comply with Warnings and Cautions in this document can result in damage to property or serious injury.
!
CAUTION
Never use the Legacy Basic
Acoustical Shell to support scenery, signs, lighting, etc.
!
CAUTION
Never move the Legacy Basic
Acoustical Shell more than a few feet when it is in the
Performance Position.
!
CAUTION
Always have the Legacy
Basic Acoustical Shell in the
Storage Position when moving to different locations.
!
CAUTION
Never use the Legacy Basic
Acoustical Shell outdoors.
!
CAUTION
To prevent damage, fold the crank handle in before storing or transporting shells.
!
CAUTION
or the crank mechanism could be damaged.
!
CAUTION
To prevent damage, transport shells individually and never nested in a group.
!
CAUTION
Canopy Panel is raised.
!
CAUTION
Do not use a powered device such as a fork lift to transport the shells.
2
I
MPORTANT
U
SER
I
NFORMATION
G
ENERAL
Copyright © 2011 by Wenger Corporation
All rights reserved. No part of the contents of this manual may be reproduced, copied, or transmitted in any form or by any means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and retrieval systems without the written permission of the publisher, unless it is for the purchaser's personal use.
Printed and bound in the United States of America.
The information in this manual is subject to change without notice and does not represent a commitment on the part of Wenger Corporation. Wenger Corporation does not assume any responsibility for any errors that may appear in this manual.
In no event will Wenger Corporation be liable for technical or editorial omissions made herein, nor for direct, indirect, special, incidental, or consequential damages resulting from the use or defect of this manual.
The information in this document is not intended to cover all possible conditions and situations that might occur. The end user must exercise caution and common sense when assembling or installing Wenger
Corporation products. If any questions or problems arise, call Wenger Corporation at 1-800-887-7145.
M
ANUFACTURER
The Legacy Basic Acoustical Shell are manufactured by:
Wenger Corporation
555 Park Drive
Owatonna, MN 55060
1-800-4WENGER (493-6437) • 1-507-455-4100 www.wengercorp.com
I
NTENDED
U
SE
•
This product is designed to be an acoustical reflector for vocal or instrumental groups. Shells may also be used as a backdrop or as a screen for other functions such as speeches and ceremonies.
•
This product is intended for indoor use in normal ambient temperature and humidity conditions.
•
This product is intended to be used only as described in these instructions.
W
ARRANTY
This product is guaranteed free of defects in materials and workmanship for five full years from date of shipment. A full warranty statement is available upon request.
3
P
RODUCT
T
ERMINOLOGY
A Legacy Basic Acoustical Shell includes a base on casters, a support frame, and three acoustical reflector panels.
The following terms are used throughout this manual:
Canopy
Panel
Shell . . . . . . . . . . . . . . . . . .One complete unit.
Base . . . . . . . . . . . . . . . . . .The assembly that supports the frame and panels.
Canopy Panel . . . . . . . . . .The highest panel. Can be either tapered or rectangular shaped.
Middle Panel . . . . . . . . . . .The panel between the Canopy and
Lower Panels.
Lower Panel . . . . . . . . . . . .The lowest panel.
Middle
Panel
Raising . . . . . . . . . . . . . . . .Setting up a shell.
Lowering . . . . . . . . . . . . . .Taking down a shell.
Storage Position . . . . . . . .When a shell is folded down.
Performance Position . . . .When a shell is fully raised.
Lower
Panel
Base
Shell
Storage Position Performance Position
4
S
TORING THE
S
HELLS
In their Storage Position, the shells can pass through a 35” x 79” opening (a typical 36" door).
A single shell unit is 72” wide x 77” high x 31½” deep
(183 x 196 x 80 cm). Each additional shell will “nest” with the others as shown, requiring an additional
10” (25 cm) of depth per unit.
Store the shells in a space that is clean and dry.
Avoid spaces with high heat, extreme cold, or very humid conditions.
Never leave a shell in the Performance Position for more than a week at a time. Always lower the shells to their Storage Position between events and rehearsals.
!
CAUTION
To prevent damage, fold the crank handle in before storing or transporting shells.
!
CAUTION
To prevent damage, transport shells individually and never nested in a group.
!
CAUTION
Do not use a powered device such as a fork lift to transport the shells.
10”
(25 cm)
5
M
OVING THE
S
HELLS
!
CAUTION
Never move the Legacy Basic
Acoustical Shell more than a few feet when it is in the
Performance Position.
!
CAUTION
Always have the Legacy
Basic Acoustical Shell in the
Storage Position when moving to different locations.
!
CAUTION
Do not move the shell if the
Canopy Panel is raised.
One person can move and steer a single shell. All four wheels are swivel casters, so steering the shell requires special attention.
If a shell is nested with other shells, prevent damage by having two people move the shell away from the other shells and through any door openings.
If a shell must be moved more than a few feet to the performance space, carefully roll it sideways at a slow pace. Slow down for corners and when moving through doorways.
The swivel casters are heavy-duty, but moving the shells over thresholds should be done carefully and at a slow speed. Use a ramp to move the shells over curbs or steps. Always move the shells sideways when going up or down a ramp.
To avoid fingerprints on the panels, have clean hands or wear clean gloves.
A
RRANGING THE
S
HELLS
Each shell is 72” (183 cm) wide. The Canopy panels on the shell can be tapered to provide a “tight” enclosure when the shell is set up on a 19 foot radius and the canopy is set at a 45° angle — the most common arrangement for choral groups. Shells with rectangular canopies can be used for other arrangements to accomplish desired effects.
While they are still in the Storage Position, arrange the shells as desired, in a row or arc.
Check for overhead clearance and for fit with risers and other equipment in the performance space.
Roll the shells about 6” (15 cm) apart, to allow clearance for raising them to the Performance Position.
Arc Configuration
Tapered Canopy Panels
Row Configuration
Rectangular Canopy Panels
6
R
AISING THE
S
HELL
Raise the shells to the Performance Position in a well-lit area.
Raise the shells to the Performance Position one at a time.
It is recommended that one person stand behind the shell to serve as a spotter, to prevent raising the shell into an obstacle or another shell.
!
CAUTION
Make sure that anyone operating the Legacy Basic
Acoustical Shell has read and understands this manual.
!
CAUTION
Never move the Legacy
Basic Acoustical Shell more than a few feet when it is in the Performance
Position.
!
CAUTION
Always have the Legacy
Basic Acoustical Shell in the Storage Position when moving to different locations.
1. Roll the shell as close to the final Performance Position as possible.
2. Insert a Stop Pin into both of the Brackets to set the Canopy Panel Performance Angle.
- Use the top set of holes to set the Canopy Panel Performance Angle to 45°.
- Use the middle set of holes to set the Canopy Panel Performance Angle to 60°.
- Use the bottom set of holes to set the Canopy Panel Performance Angle to 75°.
- Do not insert Stop Pins to set the Canopy Panel Performance Angle to 90°.
NOTE: Stop Pin placement must be in the same set of holes on both Brackets.
45° Position
Shown
60° Position
75° Position
90° Position
Uses
No Stop Pin
7
R
AISING THE
S
HELL
CONTINUED
3. Lift the Canopy Panel to raise it to the set position.
The Canopy panel will stop at the preset
Performace Angle when the Stop Pins contact the Bracket.
Canopy
Panel
45°
60°
75°
90°
4. Pull out and unfold the Crank Handle located on the back side of the shell.
Crank
Handle
PU
H
A
O
U
FO
LL
D
T A
LD
LE
N
FO
R
IN
D
TO
R
A
G
E
R
A
IS
E
LO
W
ER
5. Turn the Crank Handle clockwise slowly to raise the panels.
The Crank will stop when the panels reach the shell’s maximum height.
!
CAUTION
Do not force the crank handle or the crank mechanism could be damaged.
Crank
Handle
8
L
OWERING THE
S
HELL
1. Turn the Crank Handle counter-clockwise until the shell is completely lowered.
!
CAUTION
Do not force the crank handle or the crank mechanism could be damaged.
2. Pull out and fold in the Crank Handle located on the back side of the shell.
PU
H
A
O
U
LL
N
D
FO
FO
T A
R
S
LE
N
D
TO
R
A
G
E
R
A
IS
E
LO
W
ER
Crank
Handle
3. Pull down on the Canopy Panel to lower it down to the Storage Position.
!
CAUTION
The Canopy Panel is under tension. Pull down carefully while standing to the side.
Canopy
Panel
9
6
7
8
3
4
1
2
5
R
EPLACEMENT
P
ARTS
L
IST
Item Description Qty.
Item Description
COVER, LIFT MECHANISM, BASIC
SCREW, SM, HEX HD, #8 x 5/8, BLK ZN
CASTER, STEM, 3” x 2” WIDE
PANEL, FIXED, BASIC, 0579/0243
MAIN FRAME, PAINTED, 0370
CARRIER PANEL ASSEMBLY, CF
PILOT BEARING, PANEL
PIN, MAIN
1
6
2
4
1
1
12
1
14
15
16
9
10
11
12
13
HANDLE, FOLD, PLASTIC
CAPSCREW, GD2, ZP, 5/16-18 x 2-3/4
HANDLE, CRANK
WASHER, LOCK, 5/16, ZP, HELICAL
FOOT, PLUG-IN, ASSEMBLY
CAPSCREW, HEX HD, ZP, 3/8-16 x 2.5
NUT, LOCK, HEX HD, ZP, 3/8-16
CAP, 1.00 ID x 1.00 LNG, BLK
4
4
1
Qty.
1
1
1
1
2
10
A
SSEMBLY
CONTINUED
9
11
10
12
2
16
1
13
14
3
11
15
5
4
6
8
7
M
AINTENANCE
C
LEANING
Use a soft, damp cloth to clean all surfaces. Never hose down the shells or soak any components.
For smudges or fingerprints, dampen a cloth with any standard non-abrasive household cleaner and wipe clean.
M
ECHANICAL
C
HECK
Periodically (every three or four uses) check for loose or damaged parts and for loose fasteners.
Replace or repair damaged parts promptly. Refer to the Replacement Parts List.
!
CAUTION
Do not make adjustments to the lift mechanism.
Contact Wenger Customer
Service for repair options.
P
ANEL
R
EPAIR
Panels are of lightweight composite construction and made of durable materials. If accidentally damaged, repairs can be made with common fillers and paint.
!
CAUTION
Do not remove the canopy or middle panels.
Contact Wenger Customer
Service for repair options.
12