advertisement
JF29 NT Preliminary Specifications group • S
2-WAY SELF-POWERED LOUDSPEAKER 90° × 45°
See NOTES TABULAR DATA for details
CONFIGURATION
Subsystem:
Transducer Loading
Vented
Horn-loaded
LF 1x 12 in cone
HF 1x 1.4 in exit, 3 in voice coil compression driver
Operating Mode:
Amplifier Channels
Bi-amp LF, HF
ACOUSTICAL PERFORMANCE
Operating Range: 55 Hz to 20 kHz
Nominal Beamwidth:
Signal Processing
DSP w/ EAW Focusing
• Comprehensive integration
• EAW Focusing
• U-Net (audio and communications network)
• EAW Pilot Control and communications
• 1500 watts of class leading power
APPLICATIONS
Corporate A/V, any small to medium sized live sound reinforcement, performing arts venues, houses of worship, retail, ballrooms, theaters, theme parks.
DESCRIPTION
The JF
NT
Series of comprehensively integrated 2-way sound reinforcement systems elevate the notion of power and utility.
Each JF
NT
features premium neodymium components, 1500W of amplification, revolutionary EAW Focusing processing, EAW Pilot software-accessible front-end DSP, the proprietary U-Net audio and communications network and the JF Series adaptable enclosure design. All models natively offer a combination of portable features and M10 installation points. Available universal accessories include trim plates that hide handles and provide a connection point for u-brackets and quick release flytrack segments that integrate into any enclosure and adjustable legs for use as a stage monitor.
ORDERING DATA
Description
EAW JF29
NT
Black Active Speaker 115 V
EAW JF29
NT
Black Active Speaker 230 V
Optional Accessories
Part Number
2034631-00
2034631-01
M10 × 37mm Forged Shoulder Eyebolt
EAW U-Bracket Adjustable S1 BLK [UBKT-S1]
EAW ACC Leg Adjustable S (2 Per) [ACC-LGS]
EAW ACC Flytrack S (2 Per) [ACC-FTS]
EAW ACC Cover Plate S (2 Per) BLK [ACC-CPS]
Fly Clip with Ring
0029818
2035474
2035438
2035439
2035473
0001386
COMPLIANCE:
CE EN 60065:2002, EN55103-1:1997, EN 55103-2:1997,
EN 55103-1, EN55103-2, EN60065
CSA CAN/CSA 60065-03, UL Std No. 60065-03
Axial Output Limit (whole space SPL):
Average
Calculated LF/HF 124 dB
Peak
130 dB
ELECTRICAL PERFORMANCE
Input
Type Electronically balanced XLRF
Sensitivity 2.5 V / 10 dBu at Limit 6.2 V / 18 dBu at Clip
Impedance 20 k ohm (balanced to chassis), 10 k ohm (unbalanced)
Wiring Pin 1: chassis, Pin 2: signal +, Pin 3: signal -
Loop Electronically balanced XLRM
DSP (50 Mflop 32 bit Sharc):
Encoding 24 Bit / 48 kHz
User Addressable DSP
Array
EQ 10 Parametric
Amplifier
Level 15 dB +/-
LF
Type Modified Class D
Maximum Output 63 V, 1000 W @ 4 ohm
THD + noise < 0.3%
Dynamic Range > 105 dB
Driver Protection Integral DSP limiting
AC Mains (Nominal)
Box
10 Parametric
15 dB +/-
HF
Modified Class D
45 V, 500 W @ 4 ohm
< 0.1%
> 102 dB
Current:
Input 100 V to 120 V
Frequency 50 Hz to 60 Hz
Idle 0.25 A
In Rush 0.9 A
Output Limit 1.6 A
Fuse Rating 10 A
220 V to 240 V
50 Hz to 60 Hz
0.15 A
0.6 A
1.0 A
6.3 A
Input Selection Analog, AES Ch 1, AES Ch 2, U-Net (1 - 64)
Communication USB, U-Net 1, U-Net 2
CONTROLS
High Pass Filter 55 Hz / 80 Hz / 110 Hz
Mode Normal / Coupled / Monitor
INDICATORS (LED)
Signal Present
Limiter Active
Amplifier Status
System Gain
Rear Speaker DSP
U-Net Status
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
EAW products are continually improved. All specifi cations are therefore subject to change without notice. Part Number: RD0525 Rev A00 October 2010
JF29 NT Preliminary Specifications group • S
NOTE: This drawing has been reduced. Do not scale.
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
EAW products are continually improved. All specifi cations are therefore subject to change without notice. Part Number: RD0525 Rev A00 October 2010
JF29 NT Preliminary Specifications
PERFORMANCE DATA
See NOTES GRAPHIC DATA for details
Frequency Response: Processed Multi-Amp
Complete = blue
10
0
-10
-20
-30
-40
-50
10 100 1000 20000
Frequency (Hz)
Beamwidth (-6 dB SPL Points)
Horizontal = orange Vertical = black
360 group • S
Phase Linearity
Complete = blue
180
135
90
45
-0
-40
-90
-135
-180
10 100 1000 20000
Frequency (Hz)
Directivity Index
Complete = pink
20
100
10
10
1
100 1000 20000
Frequency (Hz)
0
10 100 1000 20000
Frequency (Hz)
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
EAW products are continually improved. All specifi cations are therefore subject to change without notice. Part Number: RD0525 Rev A00 October 2010
JF29 NT Preliminary Specifications
HORIZONTAL POLAR DATA
See NOTES GRAPHIC DATA for details
90˚
135˚ 45˚
180˚ 0˚
100Hz
125Hz
160Hz
200Hz
-135˚ -45˚
-90˚
180˚
135˚
-135˚
90˚
180˚
135˚
-135˚
45˚
-45˚
0˚
250Hz
315Hz
400Hz
500Hz
180˚
135˚
-135˚
-90˚
90˚
180˚
135˚
-135˚
45˚
-45˚
0˚
135˚
630Hz
800Hz
1000Hz
1250Hz
180˚
-135˚
-90˚
90˚
-90˚
-90˚
90˚
-90˚
90˚ group • S
45˚
-45˚
0˚
1600Hz
2000Hz
2500Hz
3150Hz
45˚
-45˚
0˚
4000Hz
5000Hz
6300Hz
8000Hz
45˚
0˚
10000Hz
12500Hz
16000Hz
-45˚
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
EAW products are continually improved. All specifi cations are therefore subject to change without notice. Part Number: RD0525 Rev A00 October 2010
JF29 NT Preliminary Specifications
VERTICAL POLAR DATA
See NOTES GRAPHIC DATA for details
90˚
135˚ 45˚
180˚ 0˚
100Hz
125Hz
160Hz
200Hz
-135˚ -45˚
-90˚
180˚
135˚
-135˚
90˚
180˚
135˚
-135˚
45˚
-45˚
0˚
250Hz
315Hz
400Hz
500Hz
180˚
135˚
-135˚
-90˚
90˚
180˚
135˚
-135˚
45˚
-45˚
0˚
135˚
630Hz
800Hz
1000Hz
1250Hz
180˚
-135˚
-90˚
90˚
-90˚
-90˚
90˚
-90˚
90˚ group • S
45˚
-45˚
0˚
1600Hz
2000Hz
2500Hz
3150Hz
45˚
-45˚
0˚
4000Hz
5000Hz
6300Hz
8000Hz
45˚
0˚
10000Hz
12500Hz
16000Hz
-45˚
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
EAW products are continually improved. All specifi cations are therefore subject to change without notice. Part Number: RD0525 Rev A00 October 2010
JF29 NT Preliminary Specifications
INPUT PANEL
CLIP
LIMITER ACTIVE
SIGNAL PRESENT
ALL ON
INPUT
MUTE
PUSH
2
3
1
COUPLED
MONITOR group • S
SIGNAL DIAGRAM
2-Way, Bi-Amp (LF, HF)
THRU
IN
DSP PC BOARD
INPUT A/D
HPF
EQ
LIMIT
DELAY
LPF
EQ
LIMIT
DELAY
D/A
D/A
AMPLIFIER &
POWER SUPPLY
ASS’Y
AMP
500 W @ 4 ohm
AMP
1000 W @ 4 ohm
HF
LF
DIGITAL DEVICE AS DESCRIBED BY FCC RULES AND THE
CANADIAN DEPARTMENT OF COMMUNICATIONS, ICES-003.
THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO
FREQUENCY ENERGY AND MAY CAUSE HARMFUL INTERFERENCE
TO RADIO COMMUNICATIONS. OPERATION OF THIS EQUIPMENT IN
A RESIDENTIAL AREA IS LIKELY TO CAUSE INTERFERENCE TO
ELECTRICAL DEVICES.
AC MAINS
100-120 V
50-60 Hz 140W
LEGEND
DSP :
HPF:
LPF:
LF/MF/HF:
AMP:
EAW UX8800 Digital Signal Processor –or–
Integral Digital Signal Processing for NT products.
High Pass Filter for crossover –or–
Recommended High Pass Filter.
Low Pass Filter for crossover.
Low Frequency / Mid Frequency / High Frequency.
User Supplied Power Amplifier –or–
XVR:
Integral Amplifier for NT products.
Passive LPFs, HPFs, and EQ integral to the loudspeaker.
EAW Focusing: Digital Signal Processor capable of implementing EAW Focusing.
NOTES
TABULAR DATA
1. Measurement/Data Processing Systems: Primary - FChart: proprietary EAW software; Secondary - Brüel & Kjær 2012.
2. Microphone Systems: Earthworks M30; Brüel & Kjær 4133
3. Measurements: Dual channel FFT; length: 32 768 samples; sample rate: 48 kHz; logarithmic sine wave sweep.
4. Measurement System Qualifi cation (includes all uncertainties): SPL: accuracy +/-0.2 dB @ 1 kHz, precision +/-0.5 dB 20 Hz to 20 kHz, resolution 0.05 dB; Frequency: accuracy +/-1 %, precision +/-0.1
Hz, resolution the larger of 1.5 Hz or 1/48 octave; Time: accuracy +/-10.4 μs, precision +/-0.5 μs, resolution 10.4 μs; Angular: accuracy +/-1°, precision +/-0.5°, resolution 0.5°.
5. Environment: Measurements time-windowed and processed to eliminate room effects, approximating an anechoic environment. Data processed as anechoic or fractional space, as noted.
6. Measurement Distance: 7.46 m. Acoustic responses represent complex summation of the subsystems at 20 m. SPL is referenced to other distances using the Inverse Square Law.
7. Enclosure Orientation: For beamwidth and polar specifi cations, as shown in Mechanical Specifi cation drawing.
8. Volts: Measured rms value of the test signal.
9. Watts: Per audio industry practice, “loudspeaker watts” are calculated as voltage squared divided by rated nominal impedance. Thus, these are not True Watt units of energy as defi ned
by International Standard.
10. SPL: (Sound Pressure Level) Equivalent to the average level of a signal referenced to 0 dB SPL = 20 microPascals.
11. Subsystem: This lists the transducer(s) and their acoustic loading for each passband. Sub = Subwoofer, LF = Low Frequency, MF = Mid Frequency, HF = High Frequency.
12. Operating Mode: User selectable confi gurations. Between system elements, a comma (,) = separate amplifi er channels; a slash (/) = single amplifi er channel. DSP = Digital Signal Processor.
IMPORTANT: To achieve the specifi ed performance, the listed external signal processing must be used with EAW-provided settings.
13. Operating Range: Range where the processed Frequency Response stays within -10 dB SPL of the power averaged SPL within this range; measured on the geometric axis. Narrow band
dips are excepted.
14. Nominal Beamwidth: Design angle for the -6 dB SPL points, referenced to 0 dB SPL as the highest level.
15. Axial Sensitivity: Power averaged SPL over the Operating Range with an input voltage that would produce 1 W at the nominal impedance; measured with no external processing on
the geometric axis, referenced to 1 m.
16. Nominal Impedance: Selected 4, 8, or 16 ohm resistance such that the minimum impedance point is no more than 20% below this resistance over the Operating Range.
17. Accelerated Life Test: Maximum test input voltage applied with an EIA-426B defi ned spectrum; measured with recommended signal processing and Recommended Protection Filter.
18. Calculated Axial Output Limit: Highest average and peak SPLs possible during the Accelerated Life Test. The Peak SPL represents the 2:1 (6 dB) crest factor of the Life Test signal.
19. High Pass Filter: This helps protect the loudspeaker from excessive input signal levels at frequencies below the Operating Range.
GRAPHIC DATA
1. Resolution: To remove insignifi cant fi ne details, 1/12 octave cepstral smoothing was applied to acoustic frequency responses and 1/3 octave cepstral smoothing was applied to the beamwidth and
impedance data. Other graphs are plotted using raw data.
2. Frequency Responses: Variation in acoustic output level with frequency for a constant input signal. Processed: normalized to 0 dB SPL. Unprocessed inputs: 2 V (4 ohm nominal impedance), 2.83 V (8
ohm nominal impedance), or 4 V (16 ohm nominal impedance) referenced to a distance of 1 m.
3. Processor Response: The variation in output level with frequency for a constant input signal of 0.775 V = 0 dB reference.
4. Beamwidth: Average angle for each 1/3 octave frequency band where, starting from the rear of the loudspeaker, the output fi rst reaches -6 dB SPL referenced to 0 dB SPL as the highest level. This method
means the output may drop below -6 dB SPL within the beamwidth angle.
5. Impedance: Variation in impedance magnitude, in ohms, with frequency without regard to voltage/current phase. This means the impedance values may not be used to calculate True Watts (see 9 above).
6. Polar Data: Horizontal and vertical polar responses for each 1/3 octave frequency band 100 Hz to 16 kHz or Operating Range.
Eastern Acoustic Works • One Main Street • Whitinsville, MA 01588 • tel 800 992 5013 / 508 234 6158 • fax 508 234 8251 • www.eaw.com
EAW products are continually improved. All specifi cations are therefore subject to change without notice. Part Number: RD0525 Rev A00 October 2010
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
advertisement