Digital Equipment Corporation SF400 DECarray DECarray cabinet, SF3x, SF7x storage enclosure, TF8x7 magazine tape ISE Installation Guide
Below you will find brief information for SF400 DECarray, storage enclosure SF3x, storage enclosure SF7x, magazine tape ISE TF8x7. This manual provides detailed steps to install and configure DECarray cabinets, SF-series storage enclosures and magazine tape ISEs in the DECarray cabinet. The DECarray cabinet can be used with any CPU system that has DSSI interface capability.
Advertisement
Advertisement
SF400 DECarray
Installation Guide
Order Number: EK–SF400–IG. C01
This manual provides the steps to install and configure DECarray cabinets, and SF-series storage enclosures and magazine tape ISEs in the DECarray cabinet.
Digital Equipment Corporation
Maynard, Massachusetts
November 1993
Possession, use, or copying of the software described in this documentation is authorized only pursuant to a valid written license from Digital, an authorized sublicenser, or the identified licenser.
NOTE: This equipment generates, uses, and may emit radio frequency energy. The equipment has been type tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Any changes or modifications made to this equipment may void the user’s authority to operate the equipment.
Operation of this equipment in a residential area may cause interference in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference.
WARNING
This is a Class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
While Digital believes the information included in this publication is correct as of the date of publication, it is subject to change without notice.
Digital Equipment Corporation makes no representations that the interconnection of its products in the manner described in this document will not infringe existing or future patent rights, nor do the descriptions contained in this document imply the granting of licenses to make, use, or sell equipment or software in accordance with the description.
© Digital Equipment Corporation 1992, 1993.
All Rights Reserved.
Printed in the United States of America.
DEC, DECUS, DSSI, KFMSA, KFQSA, MicroVAX, MicroVMS, MSCP, PDP, Q-bus, TMSCP,
UNIBUS, VAX, VAXcluster, VAXserver, VAX Performance Advisor, VMS, XMI, and the DIGITAL logo are trademarks of Digital Equipment Corporation.
This document was prepared using VAX DOCUMENT Version 2.1.
Contents
Preface
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Introduction
1.1
1.2
SF400 DECarray Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF3x and SF7x Storage Enclosures Overview . . . . . . . . . . . . . . .
2 DECarray Site Preparation
3 Unpacking the DECarray Cabinet
3.1
3.2
3.3
3.4
3.5
3.6
3.7
3.8
Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Environmental Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the DECarray Cabinet from the Pallet . . . . . . . . . . . .
Placing the DECarray Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . .
Leveling the Array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the Trim Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inspecting the DECarray Cabinet . . . . . . . . . . . . . . . . . . . . . . . .
4 Configuring, Cabling, and Labeling the DECarray Cabinet
4.1
4.1.1
4.2
4.2.1
4.2.2
4.3
4.3.1
4.3.2
4.3.3
4.4
Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Typical Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Required Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Setting the Node ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DECarray Cabinet and Cable Labels . . . . . . . . . . . . . . . . . . . . . .
Completing the System Configuration Sheet . . . . . . . . . . . . .
Filling Out the Labels (Single-System) . . . . . . . . . . . . . . . . .
Placing the Labels (Single-System) . . . . . . . . . . . . . . . . . . . .
Powering Up the DECarray Cabinet (Single-System) . . . . . . . . .
xi
1–1
1–6
3–1
3–4
3–4
3–5
3–8
3–9
3–10
3–10
4–2
4–2
4–4
4–6
4–7
4–7
4–8
4–8
4–8
4–11 iii
4.4.1
4.5
4.5.1
4.5.2
4.5.2.1
4.5.3
4.5.4
Single-System Final Verification . . . . . . . . . . . . . . . . . . . . . .
Installing Add-On Storage Elements . . . . . . . . . . . . . . . . . . . . . .
Add-On Configuration Overview . . . . . . . . . . . . . . . . . . . . . .
Typical Add-On Configurations . . . . . . . . . . . . . . . . . . . . . . .
SF400 DECarray Cabinet Locations . . . . . . . . . . . . . . . .
Configuration Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing Dual Power Controllers . . . . . . . . . . . . . . . . . . . . .
5 Installing the Magazine Tape ISE in a DECarray Cabinet
5.1
5.1.1
5.1.2
5.1.2.1
5.2
5.2.1
5.2.2
5.3
5.3.1
5.3.2
5.3.3
5.4
5.5
5.6
5.7
Steps for Installing the Magazine Tape ISE . . . . . . . . . . . . . . . . .
Unpacking the Magazine Tape ISE . . . . . . . . . . . . . . . . . . . .
Where to Install the Magazine Tape ISE . . . . . . . . . . . . . . . .
Configuration Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing TF8x7-Series Tape Drives . . . . . . . . . . . . . . . . . . . . . .
Accessing the Cabinet Rack Space . . . . . . . . . . . . . . . . . . . . .
Removing the Cabinet Side Panels . . . . . . . . . . . . . . . . . . . .
Chassis Rail Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chassis Rail Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Right Position Chassis Rail Assembly Installation . . . . . . . . .
Left Position Chassis Rail Assembly Installation . . . . . . . . . .
Mounting the TF8x7-Series Tape Drive Enclosure . . . . . . . . . . . .
Installing the Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the Cabinet Door Tape Bezel Kit . . . . . . . . . . . . . . . . .
Reinstalling Exterior Cabinet Panels . . . . . . . . . . . . . . . . . . . . . .
Cabling the Magazine Tape ISE . . . . . . . . . . . . . . . . . . . . . . . . . .
5.8
5.9
5.9.1
Powering Up the Magazine Tape ISE . . . . . . . . . . . . . . . . . . . . .
Updating the System Configuration Sheet . . . . . . . . . . . . . . .
5.9.2
Completing the System Configuration Sheet . . . . . . . . . . . . .
5.10
Labeling the DSSI Cables and Magazine Tape ISE . . . . . . . . . . .
5.10.1
5.10.2
Labeling the Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Labeling the Magazine Tape ISE . . . . . . . . . . . . . . . . . . . . . .
5.11
Final Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.1
6.1.1
6.1.2
6.1.2.1
6.2
6.2.1
6.2.2
Steps for Installing the SF7x Storage Enclosure . . . . . . . . . . . . .
Unpacking the SF7x Storage Enclosure . . . . . . . . . . . . . . . . .
Where to Install the SF7x Storage Enclosure . . . . . . . . . . . .
Configuration Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessing the Cabinet Rack Space . . . . . . . . . . . . . . . . . . . . .
Removing the Cabinet Side Panels . . . . . . . . . . . . . . . . . . . .
iv
4–13
4–13
4–14
4–14
4–15
4–15
4–17
5–10
5–13
5–15
5–18
5–21
5–24
5–24
5–25
5–27
5–2
5–2
5–4
5–4
5–5
5–8
5–8
5–10
5–28
5–28
5–31
5–31
5–31
5–33
6–2
6–2
6–4
6–4
6–5
6–7
6–7
6.3
6.3.1
6.3.2
6.3.3
6.4
6.5
6.6
6.7
6.8
6.9
6.9.1
Chassis Rail Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chassis Rail Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Right Position Chassis Rail Assembly Installation . . . . . . . . .
Left Position Chassis Rail Assembly Installation . . . . . . . . . .
Mounting the SF7x Storage Enclosure . . . . . . . . . . . . . . . . . . . . .
Installing the Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring the SF7x Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . .
Reinstalling Exterior Cabinet Panels . . . . . . . . . . . . . . . . . . . . . .
Cabling the SF7x Storage Enclosure . . . . . . . . . . . . . . . . . . . . . .
Powering Up the SF7x Storage Enclosure . . . . . . . . . . . . . . . . . .
Updating the System Configuration Sheet . . . . . . . . . . . . . . .
Completing the System Configuration Sheet . . . . . . . . . . . . .
6.9.2
6.10
Labeling the DSSI Cables and SF7x Storage Enclosure . . . . . . . .
6.10.1
6.10.2
Labeling the Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Labeling the SF7x Storage Enclosure . . . . . . . . . . . . . . . . . .
6.11
Final Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.1
7.2
7.3
7.4
7.4.1
7.4.2
7.5
7.5.1
7.5.2
7.5.3
7.6
7.7
7.8
7.9
7.9.1
Unpacking the SF3x Storage Enclosure . . . . . . . . . . . . . . . . . . . .
Where to Install the SF3x Storage Enclosure . . . . . . . . . . . . . . .
Checking the System Configuration Sheet . . . . . . . . . . . . . . . . . .
Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessing the Cabinet Rack Space . . . . . . . . . . . . . . . . . . . . .
Removing the Cabinet Side Panels . . . . . . . . . . . . . . . . . . . .
Chassis Rail Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chassis Rail Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Right Position Chassis Rail Assembly Installation . . . . . . . . .
Left Position Chassis Rail Assembly Installation . . . . . . . . . .
Mounting the SF3x Storage Enclosure . . . . . . . . . . . . . . . . . . . . .
Installing the Power Cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring the SF3x Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . .
Cabling the SF3x Enclosure in the DECarray Cabinet . . . . . . . .
Through-Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . .
Identifying DSSI Connectors on the System I/O Panel . .
7.9.1.1
7.9.1.2
7.9.1.3
Cabling with a Magazine Tape ISE . . . . . . . . . . . . . . . . .
Cabling Positions 2, 3, 4, 7, and 8 . . . . . . . . . . . . . . . . . .
7.9.2
Split-Bus Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.10
Powering Up the SF3x Enclosure . . . . . . . . . . . . . . . . . . . . . . . . .
7.10.1
Updating the System Configuration Sheet . . . . . . . . . . . . . . .
7.11
Labeling the DSSI Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.11.1
7.11.2
Filling Out the Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Labeling the Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6–31
6–33
6–33
6–34
6–37
6–37
6–37
6–37
6–9
6–9
6–11
6–14
6–17
6–20
6–23
6–30
7–15
7–19
7–22
7–25
7–28
7–37
7–39
7–39
7–2
7–3
7–5
7–9
7–11
7–11
7–13
7–13
7–40
7–42
7–42
7–45
7–46
7–46
7–46
7–47 v
Figures
1–1
1–2
1–3
1–4
2–1
2–2
3–1
3–2
3–3
3–4
3–5
3–6
3–7
3–8
3–9
4–1
4–2
4–3
4–4
4–5
7.12
Final Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Installation Troubleshooting
8.1
8.2
8.3
8.4
8.5
Troubleshooting the Storage Enclosure . . . . . . . . . . . . . . . . . . . .
Removing an RF Disk ISE from an SF3x Storage Enclosure . . . .
Removing an RF Disk ISE from an SF7x Storage Enclosure . . . .
Bringing the RF Disk ISE On Line . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting the Magazine Tape ISE . . . . . . . . . . . . . . . . . . .
A DECarray Configuration Sheets
Index
Front View of the DECarray Cabinet . . . . . . . . . . . . . . . . . . .
Back View of the DECarray Cabinet . . . . . . . . . . . . . . . . . . .
SF3x Series Storage Enclosure . . . . . . . . . . . . . . . . . . . . . . .
SF7x Series Storage Enclosure . . . . . . . . . . . . . . . . . . . . . . .
Minimum Clearance Required for Installation . . . . . . . . . . . .
NEMA Plugs for 881 Power Controller . . . . . . . . . . . . . . . . .
Contents of Shipping Container . . . . . . . . . . . . . . . . . . . . . . .
Ramp Installation on Shipping Pallet . . . . . . . . . . . . . . . . . .
Shipping Bolts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DECarray Cabinet Removal from the Pallet . . . . . . . . . . . . .
Adjusting Leveler Feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF3x Storage Enclosure Power Connection and Voltage
Selection With Rear Cover Removed . . . . . . . . . . . . . . . . . . .
SF7x Storage Enclosure Power Connection and Voltage
Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Magazine Tape Power Connection and Voltage Selection . . . .
Single Host Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single Host Split Configuration . . . . . . . . . . . . . . . . . . . . . . .
Middle Node 2-Host Configuration . . . . . . . . . . . . . . . . . . . . .
Middle Node 3-Host Configuration . . . . . . . . . . . . . . . . . . . . .
End Node 2-Host Configuration with SF7x . . . . . . . . . . . . . .
7–47
8–1
8–4
8–9
8–16
8–16
3–13
3–14
3–15
4–3
4–3
4–3
4–4
4–4
1–2
1–3
1–7
1–9
2–2
2–3
3–3
3–6
3–7
3–8
3–9
3–12 vi
6–2
6–3
6–4
6–5
6–6
6–7
6–8
6–9
6–10
6–11
6–12
6–13
6–14
6–15
5–3
5–4
5–5
5–6
5–7
5–8
5–9
5–10
4–6
4–7
4–8
4–9
4–10
4–11
4–12
4–13
5–1
5–2
5–11
5–12
5–13
5–14
6–1
End Node 2-Host Configuration with SF3x . . . . . . . . . . . . . .
End Node 3-Host Configuration with SF7x . . . . . . . . . . . . . .
End Node 3-Host Configuration with SF3x . . . . . . . . . . . . . .
Placing a Label on a DSSI Cable . . . . . . . . . . . . . . . . . . . . . .
Placing a Label on the SF7x Storage Enclosure . . . . . . . . . . .
Placing a Label on the Magazine Tape ISE . . . . . . . . . . . . . .
Power Controller Circuit Breaker . . . . . . . . . . . . . . . . . . . . .
Cabinet Loading Positions (Front View) . . . . . . . . . . . . . . . . .
TF8x7-Series Tape Drive Installation . . . . . . . . . . . . . . . . . .
Cabinet Side Panel Removal and Installation . . . . . . . . . . . .
Cabinet Frame Mounting Hole Locations . . . . . . . . . . . . . . . .
Chassis Rail Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Right Position Chassis Rail Installation . . . . . . . . . . . . . . . . .
Left Position Chassis Rail Assembly Installation . . . . . . . . . .
Right Position Tape Drive Mounting . . . . . . . . . . . . . . . . . . .
Left Position Tape Drive Mounting . . . . . . . . . . . . . . . . . . . .
AC Power Switch, Voltage Selections, and Power Cord . . . . .
Typical Single-System Bus Configurations . . . . . . . . . . . . . . .
System Configuration Sheet (Single-System) . . . . . . . . . . . . .
System Configuration Sheet (Dual-System) . . . . . . . . . . . . . .
Placing a Label on a DSSI Cable . . . . . . . . . . . . . . . . . . . . . .
Placing a Label on the Magazine Tape ISE . . . . . . . . . . . . . .
SF7x Storage Enclosure Installation . . . . . . . . . . . . . . . . . . .
Cabinet Side Panel Removal and Installation . . . . . . . . . . . .
Cabinet Frame Mounting Hole Locations . . . . . . . . . . . . . . . .
Chassis Rail Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Right Position Chassis Rail Installation . . . . . . . . . . . . . . . . .
Left Position Chassis Rail Assembly Installation . . . . . . . . . .
Right Position SF7x Enclosure Mounting . . . . . . . . . . . . . . . .
Left Position SF7x Enclosure Mounting . . . . . . . . . . . . . . . . .
Power Connection and Voltage Selection . . . . . . . . . . . . . . . .
Changing an SF7x Enclosure to Split-Bus Mode . . . . . . . . . .
Adjusting the OCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DSSI ID Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the OCP on the SF7x Enclosure . . . . . . . . . . . . . . .
Drive DC Power Switches . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Power Switch, Voltage Selections, and Power Cord . . . . .
6–8
6–10
6–11
6–13
6–16
6–18
6–19
6–22
6–24
6–25
6–26
6–28
6–29
6–30
5–11
5–12
5–14
5–17
5–19
5–20
5–22
5–26
4–5
4–5
4–6
4–9
4–9
4–10
4–12
4–16
5–7
5–9
5–29
5–30
5–31
5–32
6–6 vii
viii
6–16
6–17
6–18
6–19
6–20
7–1
7–2
7–3
7–4
7–18
7–19
7–20
7–21
7–22
7–23
7–24
7–25
7–26
8–1
8–2
8–3
8–4
7–5
7–6
7–7
7–8
7–9
7–10
7–11
7–12
7–13
7–14
7–15
7–16
7–17
Typical Single-System Bus Configurations . . . . . . . . . . . . . . .
System Configuration Sheet (Single-System) . . . . . . . . . . . . .
System Configuration Sheet (Dual-System) . . . . . . . . . . . . . .
Placing a Label on a DSSI Cable . . . . . . . . . . . . . . . . . . . . . .
Placing a Label on the SF7x Storage Enclosure . . . . . . . . . . .
DECarray Storage Enclosure Locations . . . . . . . . . . . . . . . . .
Single-System Configuration Sheet . . . . . . . . . . . . . . . . . . . .
DSSI VAXcluster System Configuration Sheet
(Two-System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DSSI VAXcluster System Configuration Sheet
(Three-System) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF3x Storage Enclosure Installation . . . . . . . . . . . . . . . . . . .
Cabinet Side Panel Removal and Installation . . . . . . . . . . . .
Cabinet Frame Mounting Hole Locations . . . . . . . . . . . . . . . .
Chassis Rail Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Right Position Chassis Rail Installation . . . . . . . . . . . . . . . . .
Left Position Chassis Rail Assembly Installation . . . . . . . . . .
Right Position SF3x Enclosure Mounting . . . . . . . . . . . . . . . .
Left Position SF3x Enclosure Mounting . . . . . . . . . . . . . . . . .
Power Connection and Voltage Selection . . . . . . . . . . . . . . . .
Changing an SF3x Enclosure to Split-Bus Mode . . . . . . . . . .
Adjusting the OCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DSSI ID Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF3x Transition Module DSSI Node ID Switches . . . . . . . . . .
SF3x Enclosure Front View Without Cover . . . . . . . . . . . . . .
SF3x Enclosure Rear View Without Cover . . . . . . . . . . . . . . .
Typical Single-System Bus Configurations . . . . . . . . . . . . . . .
Typical DSSI VAXcluster System Bus Configurations . . . . . .
Stripe Set Bus Configurations . . . . . . . . . . . . . . . . . . . . . . . .
Cabling an SF3x Enclosure in Through-Bus Mode . . . . . . . . .
SF3x Backplane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cabling an SF3x Enclosure in Split-Bus Mode . . . . . . . . . . . .
Placing a Label on a DSSI Cable . . . . . . . . . . . . . . . . . . . . . .
Disk ISE Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ISE Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF7x Front Cover Removal . . . . . . . . . . . . . . . . . . . . . . . . . .
Disconnecting the Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–7
7–24
7–27
7–29
7–30
7–31
7–34
7–36
7–37
7–38
7–38
7–8
7–10
7–12
7–14
7–15
7–18
7–21
7–23
7–39
7–42
7–44
7–45
7–47
8–6
8–8
8–10
8–11
6–32
6–35
6–36
6–37
6–38
7–4
7–6
8–5
8–6
8–7
8–8
A–1
A–2
A–3
A–4
A–5
Tables
5–1
5–2
5–3
5–4
5–5
6–1
6–2
6–3
6–4
1
1–1
1–2
1–3
1–4
4–1
4–2
6–5
6–6
7–1
7–2
7–3
7–4
7–5
RF Disk ISE Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Disk Wedges and Skid Plate . . . . . . . . . . . . . . . . . . . . . . . . .
Cabling the RF Disk ISE . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF7x Front Cover Replacement . . . . . . . . . . . . . . . . . . . . . . .
Single-System Configuration Sheet (Dual Port) . . . . . . . . . . .
Two-Host DSSI VAXcluster Configuration Sheet (Dual
Port) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Three-Host DSSI VAXcluster Configuration Sheet (Dual
Port) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single-System Configuration Sheet (Single Port) . . . . . . . . . .
DSSI VAXcluster Configuration Sheet (Single Port) . . . . . . . .
8–12
8–13
8–14
8–15
A–2
A–3
A–4
A–5
A–6
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DECarray Storage Positions . . . . . . . . . . . . . . . . . . . . . . . . .
DECarray Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF400 DECarray Acoustics Declaration . . . . . . . . . . . . . . . . .
Storage Enclosure Power Requirements . . . . . . . . . . . . . . . . .
Digital DSSI Cables by Option Number and Part Number . .
Loading Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Magazine Tape ISE Required Tool List . . . . . . . . . . . . . . . . .
Magazine Tape ISE Required Mounting Hardware . . . . . . . .
Loading Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Power Distribution (Single Power Controller) . . . . . . . . .
AC Power Distribution (Dual Power Controllers) . . . . . . . . . .
SF7x Storage Enclosure Required Tool List . . . . . . . . . . . . . .
Storage Enclosure Mounting Hardware Kit . . . . . . . . . . . . . .
Loading Sequences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Power Distribution (Single Power Controller) . . . . . . . . .
AC Power Distribution (Dual Power Controllers) . . . . . . . . . .
DSSI ID Switch Settings (SF7x Only) . . . . . . . . . . . . . . . . . .
SF3x Required Tool List . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SF3x Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC Power Distribution (Single Power Controller) . . . . . . . . .
AC Power Distribution (Dual Power Controllers) . . . . . . . . . .
SF3x Factory-Set DSSI Node IDs . . . . . . . . . . . . . . . . . . . . . .
5–1
5–3
5–5
5–21
5–23
6–1
6–3
6–5
6–20 xii
1–4
1–4
1–5
1–8
4–7
4–17
6–21
6–26
7–1
7–2
7–25
7–26
7–31 ix
x
7–6
8–1
DSSI Node ID Switch Settings for the SF3x Storage
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7–32
8–2
Preface
This guide provides the steps to install and configure DECarray cabinets, and
SF-series storage enclosures and magazine tape ISEs in the DECarray cabinet.
This guide is intended for Digital Services and other personnel qualified to service the DECarray cabinet.
Note
The procedures described in this guide are to be performed only by qualified service personnel.
The information in this guide is organized as follows:
• Chapter 1 contains a description of and specifications for the DECarray cabinets and SF-series storage enclosures.
• Chapter 2 contains site preparation information for a DECarray cabinet.
• Chapter 3 describes how to unpack a DECarray cabinet and where to place it with a system.
• Chapter 4 describes how to configure, cable, and label the DECarray cabinet in a single-system and a DSSI VAXcluster system configuration.
xi
Related Documentation
Table 1 lists reference documentation that supplements this guide.
Table 1 Related Documentation
Title
KFMSA Module Installation and User Manual
KFQSA Module Installation and User Manual
RFxx Series Integrated Storage Element User Guide
TF857 Magazine Tape ISE Service Manual
DECarray Owner’s Manual
DECarray SF400 Owner’s Manual
System Expansion Installation Supplement
DSSI VAXcluster Installation and Troubleshooting Manual
SF Family Label Booklet
Order Number
EK–KFMSA–IM
EK–KFQSA–IM
EK–RF7xD–UG
EK–TF857–SM
EK–SF7xS–OM
EK–SF400–OM
EK–431AB–IN
EK–410AA–MG
36–32882–01 xii
1
Introduction
This chapter provides an overview of the DECarray cabinet and the SF3x and
SF7x series storage enclosures.
1.1 SF400 DECarray Overview
The SF400 DECarray is a storage cabinet designed to hold up to a total of 10
SF-series disk enclosures and TF-series tape loaders. The cabinet doors have modular panels that allow flexibility of the storage devices. All storage device operator control panels project through the front door of the storage array to allow easy access. In addition, the SF400 DECarray cabinet provides optional dual ac power capability to provide redundant power.
The SF400 DECarray cabinet can be used with any CPU system that has
DSSI interface capability. It can be installed in any location, relative to the
CPU, allowed by the DSSI cabling length limits. The DSSI cables from the
CPU connect directly to the storage devices in the cabinet. There is no DSSI interconnect panel in the SF400 DECarray cabinet.
Note
The equipment described in this manual is listed by the Underwriters
Laboratories Incorporated and bears the UL Listing mark. The
DECarray cabinet is also certified by the Canadian Standards
Association and TUV Product Service GmbH and bears both the CSA certification and TUV GS marks.
Viewing the DECarray cabinet from the front (see Figure 1–1), note how the
SF-series storage enclosures and magazine tape ISEs are arranged in the
DECarray cabinet. Figure 1–2 shows the rear of the DECarray cabinet.
Introduction 1–1
Introduction
1.1 SF400 DECarray Overview
Figure 1–1 Front View of the DECarray Cabinet
D E
C a r ra y
1–2 Introduction
CXO-3525A-TI_R
Introduction
1.1 SF400 DECarray Overview
Figure 1–2 Back View of the DECarray Cabinet
POWER
CONTROLLER
CXO-3526A-TI_R
Introduction 1–3
Introduction
1.1 SF400 DECarray Overview
The DECarray cabinet has five levels, each with two storage enclosure positions. The levels are numbered from the bottom up. Looking from the front, odd-numbered positions are on the right, and even-numbered positions are on the left, as shown in Table 1–1.
Table 1–1 DECarray Storage Positions
Level
1
2
3
4
5
Left Position
8
10
2
4
6
Right Position
1
3
5
7
9
Specifications for the SF400 DECarray cabinet are shown in Table 1–2.
Table 1–2 DECarray Specifications
Characteristic
Dimensions (nominal)
Weight
Minimum configuration
Maximum configuration
Agency compliance
Electrical rating
SF400–XA
SF400–XD
Temperature
Humidity
Specification
170.0 cm (66.93 inches) H, 80.0 cm (31.50
inches) W, 87.25 cm (34.35 inches) D
228 kg (500 lb)
635 kg (1400 lb)
FCC, UL, IEC, CSA, TUV, and VDE
120/208 volts, 50/60 Hz, 3 phase Y, 24 amperes per phase
380-415 volts, 50/60 Hz, 3 phase Y, 16 amperes per phase
+10°C to +40°C (+50°F to +104°F)
Reduce rating by 1.8°C for each 1000 meters altitude (1.0°F for each 1000 feet altitude)
10 to 85 percent at maximum wet bulb temperature of +32°C (+90°F) and minimum dew point of +2°C (+36°F)
(continued on next page)
1–4 Introduction
Introduction
1.1 SF400 DECarray Overview
Table 1–2 (Cont.) DECarray Specifications
Characteristic Specification
Recommended Environmental Limits
1
Operating environment
Temperature
Relative humidity
Altitude
Air quality
(maximum particle count)
Air volume (at inlet)
18°C to 24°C (64.4°F to 75.2°F) with an average rate of change of 3°C/hour maximum and a step change of 3°C or less
40 to 60 percent (noncondensing) with a step change of 10 percent or less
(noncondensing)
Up to 2400 meters (8000 feet)
Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger
50 cubic feet per minute (0.026 cubic meters per second)
Nonoperating environment
Temperature
Relative humidity
Altitude
Nominal airflow through enclosure
-40°C to +66°C (-40°F to +151°F)
10 to 80 percent noncondensing
4900 meters (16,000 feet)
360 to 650 cubic feet/minute
1
These limits are for optimum equipment performance and reliability.
Table 1–3 shows the acoustics for the DECarray cabinet.
Table 1–3 SF400 DECarray Acoustics Declaration
Sound Power Level
LWAd, B
Acoustics–declared values per ISO 9296 and ISO 7779:
Product
SF400 with 10xSF3x
SF400 with 10xSF7x
Idle Operate
7.3
7.3
7.1
7.1
Sound Pressure Level
LpAm, dBA
(Bystander Positions)
Idle Operate
56 56
54 54
(continued on next page)
Introduction 1–5
Introduction
1.1 SF400 DECarray Overview
Table 1–3 (Cont.) SF400 DECarray Acoustics Declaration
Sound Power Level
LWAd, B
Sound Pressure Level
LpAm, dBA
(Bystander Positions)
Per device when installed in SF400
SF3x
SF7x
6.3
6.1
6.3
6.1
46
44
46
44
(Current values for specific configurations are available from Digital representatives.
1 B = 10 dBA. )
1.2 SF3x and SF7x Storage Enclosures Overview
The SF-series storage enclosures are available in two designs; the SF3x enclosure that contains up to 12 half-height, 3 1/2-inch ISEs, and the SF7x enclosure that contains up to 4 full-height, 5 1/4-inch ISEs.
Each disk ISE within an SF-series enclosure is independently controlled from the OCP on the front of the enclosure. A power supply in the enclosure provides the dc power for all disk ISEs installed in the enclosure. A blower fan provides air flow for cooling.
The SF3x storage enclosure (Figure 1–3) holds up to twelve RF3x series ISEs.
There are six slots in the front of the enclosure and six slots in the rear. Disk
ISEs installed in these slots plug directly into a backplane, which is cabled to a connector tray on the top rear of the storage enclosure.
The SF3x enclosure can be configured in through-bus mode or split-bus mode.
In through-bus mode, the six ISEs in the front of the SF3x enclosure are connected to a single DSSI bus, and the six ISEs in the rear of the SF3x enclosure are connected to a second DSSI bus. In split-bus mode, each end of the enclosure (front and rear) is further divided into left-side ISEs and right-side ISEs, each connected to a separate DSSI bus. Thus, in split-bus mode there are four DSSI buses, each with three drives connected to it.
1–6 Introduction
Introduction
1.2 SF3x and SF7x Storage Enclosures Overview
Figure 1–3 SF3x Series Storage Enclosure
CXO-3966A-MC
Introduction 1–7
Introduction
1.2 SF3x and SF7x Storage Enclosures Overview
The SF7x series storage enclosure (Figure 1–4) holds either two or four RF7x series ISEs. The ISEs in the SF7x storage enclosure can also be configured in split-bus or through-bus mode. In through-bus mode, all four disk ISEs are connected to a single DSSI bus. In split-bus mode, the left-side ISEs are connected to one DSSI bus, while the right-side ISEs are connected to a second
DSSI bus.
The SF-series storage enclosures have the following features:
• Both can operate in one of two modes; through-bus or split-bus.
• Each disk ISE has its own set of switches and indicators on the operator control panel (OCP).
• The enclosure power supply provides operating power to all disk ISEs and other subassemblies in the enclosure.
• The drive dc power switches for the disk ISEs are on the front panel of the storage enclosure.
Table 1–4 shows the power requirements for the enclosures.
Table 1–4 Storage Enclosure Power Requirements
Storage Enclosure
SF3x disk power requirements (steady state)
SF7x disk power requirements (steady state)
TF8x7 tape magazine power requirements (steady state)
Specification
4.5 A @ 100 to 120 Vac (60 Hz),
2.3 A @ 220 to 240 Vac (50 Hz)
4.7 A @ 100 to 120 Vac (60 Hz),
2.4 A @ 220 to 240 Vac (50 Hz)
1.1 A @ 100 to 120 Vac (60 Hz),
0.5 A @ 220 to 240 Vac (50 Hz)
1–8 Introduction
Introduction
1.2 SF3x and SF7x Storage Enclosures Overview
Figure 1–4 SF7x Series Storage Enclosure
CXO-3967A-MC
Introduction 1–9
2
DECarray Site Preparation
The DECarray cabinet is intended for installation in a Class A computer room environment. Before installing the DECarray cabinet, make sure the following conditions are met:
• The DECarray cabinet requires three-phase ac power. Each phase draws up to 24.0 amperes in a fully configured array.
• Adequate space is provided around the DECarray cabinet for opening the front and rear doors, for accessing cables, and for adequate airflow. See
Figure 2–1 for specific space requirements.
• The installation site floor can safely bear the weight of the DECarray cabinet. The DECarray cabinet with power controller weighs 228 kilograms
(500 pounds); a fully configured DECarray cabinet weighs 635 kilograms
(1400 pounds).
• The system’s configuration sheet has been correctly filled out and is up-to-date. Blank system configuration sheets can be found in Appendix A.
• An adequate number of DSSI adapter modules are installed in the system to support all the DSSI devices in the DECarray cabinet.
• The correct NEMA plug or plugs are available (Figure 2–2).
DECarray Site Preparation 2–1
DECarray Site Preparation
Figure 2–1 Minimum Clearance Required for Installation
31.50 in
800.0 mm
29.33 in
74.5 cm
DOOR
REAR
SF400
FRONT
34.45 in
87.5 cm MAX
DOOR
29.33 in
74.5 cm
CXO-3532A-MC
2–2 DECarray Site Preparation
DECarray Site Preparation
Figure 2–2 NEMA Plugs for 881 Power Controller
PLUGS GOING TO WALL OUTLET (FROM CONTROLLER)
120/208V AC 60HZ
30A
3-PHASE
WYE
USED WITH 881-A AND 881-C
POWER CONTROLLERS
5-WIRE
NEMA NO. L21-30P
220-240/380-415V AC 50HZ
20A OR 16A
3-PHASE
WYE
USED WITH 881-B
POWER CONTROLLER
5-WIRE, 4-POLE,
IEC 309
CXO-2468B
Proper grounding between the DECarray cabinet and any enclosures connected via a common DSSI bus is required.
WARNING
If the enclosures are not connected to a common ground, there is a potential for a personal safety hazard.
If the ground offset voltages generated in the power distribution system exceed allowable limits, data transmission across the DSSI bus can be affected. In this case, the systems could experience significant performance degradation or possible data corruption.
DECarray Site Preparation 2–3
DECarray Site Preparation
For a DSSI installation, the maximum ground offset voltage differential allowed between enclosures is:
DSSI Bus Length
1
Allowable Offset
Meters
Up to 20
20-25
Feet
Up to 65
65-82
DC
200 mv
40 mv
AC
70 mv (rms)
14 mv (rms)
1
The total length includes all DSSI cable lengths, internal and external to the enclosures.
Ensure that the power distribution systems meet local codes prior to DSSI system installation. In a properly wired power distribution systems with properly functioning equipment connected to it (no ground faults), there is generally no need for any further attention to grounding. The power distribution system provides a satisfactory path between enclosures.
To ensure that this is the case, perform a power system survey before installation. Check for the following conditions:
1. Do any outlets being used not have power ground connections?
2. Is the grounding prong missing on any of the computer equipment power cords?
3. Are any of the power outlet neutral connections actually ground connections?
4. Are the grounds for any of the power distribution circuits (outlets) not connected to the same power distribution panel?
5. Are any devices that are not UL or IEC approved connected to the same breaker as any of the DSSI computer equipment?
If the previous conditions do not exist, then the grounding should be adequate for DSSI operation. It is recommended that the ground offset voltage between any two enclosures be measured. However, this only provides data for that particular moment in time. Ground offset values may change as additional devices are connected to the same power source.
2–4 DECarray Site Preparation
DECarray Site Preparation
If the installation exhibits ground offset voltages between interconnected enclosures which exceed the allowable limits, use one of the following solutions.
1. Have an electrician correct any deficiencies detected during the power system survey. This is the recommended solution.
2. Install grounding cables between enclosures. Grounding cables are available from Digital Equipment Corporation, and come with the necessary hardware for installation.
Installation of additional grounding cables normally reduce the ground voltage offset sufficiently to meet the requirements. In severe cases, however, the cables may not be large enough. This is revealed by the ground offset voltage measurements. If the additional grounding cables are not adequate, the source of the ground offset voltage must be traced and either reduced or eliminated.
DECarray Site Preparation 2–5
3
Unpacking the DECarray Cabinet
Before unpacking the DECarray cabinet, ensure that the site is ready to receive it. Refer to Chapter 2 for site preparation information and to Chapter 1 for array specifications.
This chapter describes how to:
• Unpack the DECarray (Section 3.1)
• Remove the DECarray from the shipping pallet (Section 3.4)
• Place the DECarray with the system (Section 3.5)
• Level the DECarray (Section 3.6)
• Inspect the DECarray before installation (Section 3.8)
3.1 Unpacking
The DECarray is packed in a corrugated carton attached to a wooden shipping pallet. Some DECarray cabinets arrive covered with plastic protection.
Note
Before unpacking the equipment, inspect the shipping carton for signs of external damage. Report any damage to the local carrier and to
Digital Services or your local sales office.
1. Cut the shipping straps and remove the outer corrugated carton and associated packing material. Some DECarray cabinets are packaged with a plastic bag. If the DECarray arrives in a plastic bag, leave the plastic bag in place until environmental stabilization time has elapsed. Environmental stabilization occurs after 24 hours.
Unpacking the DECarray Cabinet 3–1
Unpacking the DECarray Cabinet
3.1 Unpacking
CAUTION
Failure to stabilize the equipment thermally may damage the drive media or associated electronics when the unit is powered up.
Environmental stabilization begins when the equipment is placed in the room where it is to be installed.
2. Once the array is unpacked, examine the front and rear doors, the right and left side panels, and undercarriage for any apparent damage. Report any damage.
3. Retain the shipping container and all packing materials.
Refer to Figure 3–1 for the contents of the shipping container.
3–2 Unpacking the DECarray Cabinet
Unpacking the DECarray Cabinet
3.1 Unpacking
Figure 3–1 Contents of Shipping Container
C O V E R
CARTON
CONTAINING
SKIRT KIT
CORRUGATED
BOARD
F A S T E N E R S
M A N U A L S
F A S T E N E R S
P L A S T I C O R
B A R R I E R B A G
S H I P P I N G
S T R A P S
P A L L E T
C A R T O N
C O N T A I N I N G
U N L O A D I N G
R A M P S
CXO-3533A-TI
Unpacking the DECarray Cabinet 3–3
Unpacking the DECarray Cabinet
3.2 Environmental Considerations
3.2 Environmental Considerations
The SF400 DECarray must be operated within the environmental ranges listed in Table 1–2. Consider the following when choosing a location for the SF400
DECarray cabinet:
• Allow at least 3 feet of space in front of and behind the DECarray cabinet for adequate air flow and access to the front and rear.
• Install the DECarray cabinet in a Class A computing environment.
• Have adequate power reserves to support the planned number of storage enclosures. Refer to Table 1–2 for electrical specifications.
• Ensure that the floor of the installation site can safely support the weight of the DECarray cabinet. Refer to Table 1–2 for DECarray cabinet weight specifications.
3.3 Required Tools
The following tools and equipment are needed to install the SF400 DECarray cabinet:
• 7/16-inch wrench
• 9/16-inch wrench
• 3/4-inch wrench
• Safety glasses
WARNING
Serious personal injury may result if correct safety conditions are not met. During the unpacking procedure, personnel should wear safety glasses. Inspect the ramps, ramp side rails, and metal hardware for the following defects:
• Cracks more than 25 percent of the ramp depth, either across or lengthwise on the ramp
• Knots or knotholes going through the thickness of the ramp and greater than 50 percent of the ramp width
• Loose, missing, or broken ramp side rails
3–4 Unpacking the DECarray Cabinet
Unpacking the DECarray Cabinet
3.3 Required Tools
• Loose, missing, or bent metal hardware
If any of these defects exist, DO NOT USE THE RAMP. Investigate alternate means of removing the DECarray cabinet or order a new ramp. The part number for the ramp set is 99–08897–05.
3.4 Removing the DECarray Cabinet from the Pallet
This section describes how to remove the DECarray cabinet and level it.
WARNING
Three people are required to unload the storage array.
Use the following procedure to remove the array from the shipping pallet
(Figure 3–2):
1. Remove the packing material.
2. Remove the two unloading ramps from the carton and inspect.
3. Attach the ramps to the pallet by fitting the metal prongs into the holes on the pallet. Make sure that the arrows on the ramps match up with the arrows on the pallet (Figure 3–2).
4. Extend the ramps to their full length.
5. Remove the shipping bolts (Figure 3–3).
6. Remove the shipping brackets from the cabinet levelers.
7. Screw the cabinet levelers all the way up.
WARNING
The levelers must be all the way up for the DECarray cabinet to roll properly down the unloading ramps. Failure to do so may result in the cabinet tipping off the pallet.
8. Carefully roll the DECarray cabinet down the ramps (see Figure 3–4.)
Unpacking the DECarray Cabinet 3–5
Unpacking the DECarray Cabinet
3.4 Removing the DECarray Cabinet from the Pallet
Figure 3–2 Ramp Installation on Shipping Pallet
LEFT
UNLOADING
RAMP
SHIPPING
PALLET
3–6 Unpacking the DECarray Cabinet
RIGHT RAMP
ATTACHES HERE
RIGHT
UNLOADING
RAMP
EXTEND RAMP TO
FULL LENGTH
CXO-688D_S
Unpacking the DECarray Cabinet
3.4 Removing the DECarray Cabinet from the Pallet
Figure 3–3 Shipping Bolts
LEVELER
SHIPPING
BOLT
SHIPPING
BRACKET
S H R _ X 1 1 0 2 A _ 8 9 _ S C N
Unpacking the DECarray Cabinet 3–7
Unpacking the DECarray Cabinet
3.4 Removing the DECarray Cabinet from the Pallet
Figure 3–4 DECarray Cabinet Removal from the Pallet
C X O - 9 2 4 A _ S
S H R _ X 1 1 0 4 _ 8 9 _ S C N
3.5 Placing the DECarray Cabinet
Move the DECarray cabinet to its final position.
Note
Ensure that the DECarray cabinet is within sufficient distance to the system cabinet to enable proper connection of the system DSSI cables.
3–8 Unpacking the DECarray Cabinet
Unpacking the DECarray Cabinet
3.6 Leveling the Array
3.6 Leveling the Array
Once the array is in its final position:
1. Loosen the locknuts on all four leveler feet (Figure 3–5).
2. Turn each leveler hex nut clockwise until the leveler foot contacts the floor.
3. Adjust all four feet until the cabinet is level and the load is removed from all casters. Verify that the casters spin freely.
4. Tighten the locknuts on all four leveler feet (Figure 3–5).
Figure 3–5 Adjusting Leveler Feet
LOCKNUT
LEVELER
HEX NUT
LEVELER
FOOT
C X O - 3 9 5 C _ S
S H R _ X 1 1 0 5 _ 8 9 _ S C N
Unpacking the DECarray Cabinet 3–9
Unpacking the DECarray Cabinet
3.7 Installing the Trim Kit
3.7 Installing the Trim Kit
Use the following procedure to install the trim kit around the base of the
DECarray cabinet.
1. Locate the Base Trim Kit, part number H9C02–UD, packaged separately inside the corrugated carton with the DECarray cabinet.
2. Locate the side trim right and left hand pieces. With the four bosses in the rear, use a Phillips screwdriver to push the spring loaded fastener into the mating receptacles.
3. Locate the right and left hand corner trims. Slide on the middle trim extrusion. Fasten the extrusion to the front base and rear extender. Attach as above.
Trim may be adjusted up or down slightly, to align with each other.
4. To remove, rotate spring loaded fastener 90 degrees (one quarter turn), and pull off.
3.8 Inspecting the DECarray Cabinet
Inspect the DECarray cabinet first from the front, then from the rear.
1. Open the front and rear cabinet doors.
a. Turn the two hex-Allen fasteners at the right edge of each door counterclockwise to unlock.
b. For each door, grasp the door by its edge, and pull toward you.
2. Check that all OCPs are correctly seated on each SF-series storage enclosure installed in the cabinet.
WARNING
Adhere to electrostatic discharge (ESD) procedures at all times.
3. At the rear of the DECarray cabinet, check the serial/logo label to verify that the correct voltage variation of the power controller exists to meet the power supplied to the installation site (Figure 3–6).
4. Ensure that all ac power cords going to the power controller from devices installed in the storage array are correctly seated in the power controller.
5. Ensure that the ac breaker is off (Figure 3–6).
3–10 Unpacking the DECarray Cabinet
Unpacking the DECarray Cabinet
3.8 Inspecting the DECarray Cabinet
6. Ensure that the bus switch of the power controller is in the on (left) position (Figure 3–6).
7. Check the ac power cords for each storage enclosure and magazine tape installed. Make sure that each is correctly seated.
8. Ensure that the line voltage selector switches for each storage enclosure and magazine tape are in the correct position for the power supplied by the installation site (Figures 3–7, 3–8, and 3–9).
9. Loosen the shipping screw on all magazine tapes in the storage array. This screw is in the right rear upper corner.
10. Ensure that all DSSI cables internal to the storage array are firmly seated.
Unpacking the DECarray Cabinet 3–11
Unpacking the DECarray Cabinet
3.8 Inspecting the DECarray Cabinet
Figure 3–6 Power Controller
GROMMETED
CORD
OPENING
DELAYED
(0.5 SEC)
UNDELAYED
POWER CONTROL
BUS CONNECTORS
JI3 JI2 J11 J10
BUS/OFF/ON SWITCH
(SYMBOLS CLOCKWISE FROM RIGHT)
O
CB
I
FUSE
LABEL
881
CIRCUIT
BREAKER
POWER CORD
STRAIN RELIEF
POWER
CORD
CXO-3527A-TI
3–12 Unpacking the DECarray Cabinet
Unpacking the DECarray Cabinet
3.8 Inspecting the DECarray Cabinet
Figure 3–7 SF3x Storage Enclosure Power Connection and Voltage Selection
With Rear Cover Removed
DSSI
Connectors
A
C
E
B
D
F
Power Supply
Fault Indicator
(Behind Panel)
FAULT
AC Receptacle AC Power
Switch
Line Voltage
Selected Switch
(Behind Panel)
MKV−010000437−04−92−rags
Unpacking the DECarray Cabinet 3–13
Unpacking the DECarray Cabinet
3.8 Inspecting the DECarray Cabinet
Figure 3–8 SF7x Storage Enclosure Power Connection and Voltage Selection
D S S I
C O N N E C T O R S
1 0
A C R E C E P T A C L E A C P O W E R
S W I T C H
P O W E R S U P P L Y
F A U L T I N D I C A T O R
( B E H I N D P A N E L )
L I N E V O L T A G E
S E L E C T O R S W I T C H
( B E H I N D P A N E L )
S H R - X 0 1 2 7 A - 9 0
3–14 Unpacking the DECarray Cabinet
Unpacking the DECarray Cabinet
3.8 Inspecting the DECarray Cabinet
Figure 3–9 Magazine Tape Power Connection and Voltage Selection
D S S I
C O N N E C T O R S
A C P O W E R
S W I T C H
A C R E C E P T A C L E
S H R - X 0 1 4 1 B - 9 0 - C P G
Unpacking the DECarray Cabinet 3–15
4
Configuring, Cabling, and Labeling the
DECarray Cabinet
This chapter describes how to configure, cable, and label the DECarray cabinet in single, multiple, and split-bus configurations.
Perform the configuring, cabling, and labeling only after all the installation steps required in Chapter 3 have been completed. Digital Multivendor
Customer Services or trained installers must perform these procedures.
Ensure that all precautions for site preparation have been completed (see
Chapter 2).
WARNING
Hazardous voltages are in the storage array and in the components of the DECarray cabinet.
When performing any operation involving the power source(s), turn the power controls of all storage elements and power controllers to the ‘‘off’’ position. Next, disconnect the power cable(s) from the source outlet(s).
Perform the operation, then reconnect the power cable to the source.
CAUTION
This DECarray cabinet may have two power controller cords. To reduce the risk of electric shock, disconnect power before servicing.
To completely remove power from the equipment, disconnect the two power controller cords from their source(s).
To remove power from an individual storage device inside the equipment, disconnect the individual power supply cord at the internal storage device.
Configuring, Cabling, and Labeling the DECarray Cabinet 4–1
Configuring, Cabling, and Labeling the DECarray Cabinet
To remove power from an individual power controller, disconnect the external power supply cord that supplies that power controller.
4.1 Configuration Overview
The SF400 DECarray cabinet is designed for very flexible configuration of storage device locations and cabling. The array can support single, dual, or triple host configurations, with the hosts located on one or both sides of the
DSSI buses.
The DECarray cabinet is preconfigured at the factory as a single-host system.
The storage devices are cabled, terminated, and configured as through-bus or split-bus, as appropriate. The configuration is easily changeable to dual-host or triple-host by relocating cable connections and terminators.
4.1.1 Typical Configurations
Typical cabling configurations are shown in Figure 4–1 through Figure 4–8 for one KFMSA controller in a VAX 6000/7000 system with two complete
DSSI buses. KFQSA controllers in VAX 4000 systems are cabled in the same manner, but have only one DSSI bus per controller. Each DSSI bus supports up to eight devices, including the controllers. Cabling for multiple controllers in each CPU simply repeats in the same manner as the first controller. RF7x storage devices can contain up to four drives in through-bus mode or two drives on each of the two DSSI buses in split-bus mode. RF3x storage devices can contain up to six drives on each of two DSSI buses or up to three drives on each of four DSSI buses, for a total of 12 drives per RF3x storage device.
Refer to the RF7x and RF3x owners manuals for details on their internal bus configurations.
4–2 Configuring, Cabling, and Labeling the DECarray Cabinet
Configuring, Cabling, and Labeling the DECarray Cabinet
4.1 Configuration Overview
Figure 4–1 Single Host Configuration
VAX 6000
OR 7000
SF400
TF TF SF
3x
KFMSA
DSSI BUS
CONTROLLER
CXO−3537B−RA
Figure 4–2 Single Host Split Configuration
VAX 6000
OR 7000
SF400
SF73
SPLIT
BOX
TF TF SF
7x
KFMSA
DSSI BUS
CONTROLLER
Figure 4–3 Middle Node 2-Host Configuration
VAX 6000
OR 7000
SF400
SF
7x
CXO−3538B−RA
VAX 6000
OR 7000
TF TF SF SF
KFMSA
DSSI BUS
CONTROLLER 2X
CXO−3539A−RA
Configuring, Cabling, and Labeling the DECarray Cabinet 4–3
Configuring, Cabling, and Labeling the DECarray Cabinet
4.2 Cable Routing
Figure 4–4 Middle Node 3-Host Configuration
VAX 6000
OR 7000
VAX 6000
OR 7000
SF400
VAX 6000
OR 7000
TF TF SF
7x
SF
7x
KFMSA
DSSI BUS
CONTROLLER 3X
Figure 4–5 End Node 2-Host Configuration with SF7x
VAX 6000
OR 7000
VAX 6000
OR 7000
SF400
CXO−3540B−RA
TF TF SF
7x
SF
7x
KFMSA
DSSI BUS
CONTROLLER 3X
LEGEND:
= TERMINATOR
DEC P/N 12−31281−01
CXO−3541B−RA
4.2 Cable Routing
The SF400 DECarray cabinet does not have a DSSI bulkhead. The system interconnect cables are routed from the controllers, through either of the rectangular holes in the bottom of the DECarray rear door frame, and directly to the storage devices in the array.
Note
The system cables are ALWAYS connected to a TF8x7 magazine tape subsystem first, if present.
4–4 Configuring, Cabling, and Labeling the DECarray Cabinet
Configuring, Cabling, and Labeling the DECarray Cabinet
4.2 Cable Routing
Figure 4–6 End Node 2-Host Configuration with SF3x
VAX 6000
OR 7000
VAX 6000
OR 7000
SF400
TF TF SF
3x
KFMSA
DSSI BUS
CONTROLLER 2X
CXO−3542B−RA
Figure 4–7 End Node 3-Host Configuration with SF7x
VAX 6000
OR 7000
VAX 6000
OR 7000
VAX 6000
OR 7000
SF400
TF TF SF
7x
SF
7x
KFMSA
DSSI BUS
CONTROLLER 3X
LEGEND:
= TERMINATOR
DEC P/N 12−31281−01
CXO−3543B−RA
No more than one tape loader should be configured on any one DSSI bus. Once the system cables are connected, they should be secured with tie-wraps, to the tie-wrap pads within the array cabinet.
Configuring, Cabling, and Labeling the DECarray Cabinet 4–5
Configuring, Cabling, and Labeling the DECarray Cabinet
4.2 Cable Routing
Figure 4–8 End Node 3-Host Configuration with SF3x
VAX 6000
OR 7000
VAX 6000
OR 7000
VAX 6000
OR 7000
SF400
TF TF SF
3x
KFMSA
DSSI BUS
CONTROLLER 3X
CXO−3544B−RA
4.2.1 Required Cables
Cables inside the SF400 DECarray cabinet are supplied from the factory.
Customers must order the required quantity of CPU to DECarray cables from the cable options listed in Table 4–1. The BC21Q cables are for VAX 6000 and
VAX 7000 systems. The BC22Q cables are for VAX 4000 systems.
Note
The maximum length of each individual DSSI interconnect
(measured from end terminator to end terminator and including all interconnecting cables and internal enclosure wiring) must not exceed a maximum qualified length. These lengths are 82 feet (25 meters) in a computer room, and 65.6 feet (20 meters) in an office environment.
4–6 Configuring, Cabling, and Labeling the DECarray Cabinet
Configuring, Cabling, and Labeling the DECarray Cabinet
4.2 Cable Routing
Table 4–1 Digital DSSI Cables by Option Number and Part Number
Digital Option Number
BC21Q–09
BC21Q–16
BC21Q–25
BC21Q–50
BC22Q–09
BC22Q–16
BC22Q–25
BC22Q–50
Digital Part Number
17–02382–02
17–02382–05
17–02382–06
17–02382–10
17–02710–01
17–02710–02
17–02710–03
17–02710–04
Length (feet)
9.0
16.0
25.0
50.0
9.0
16.0
25.0
50.0
4.2.2 Setting the Node ID
Once the system cabling is complete, verify that all devices on any single DSSI bus have a unique node ID set. The RF7x device IDs are set on the OCP.
The RF3x device IDs are set internally. Refer to the RF7x and RF3x owners manuals for detailed instructions on setting node IDs.
Note
The TF8x7 tape loader IDs are defined as Node zero by convention.
4.3 DECarray Cabinet and Cable Labels
With the large number of storage elements possible in the SF400 DECarray cabinet, it is important to clearly label all storage elements according to bus, node, and associated cables that make up that particular piece of the system.
To aid in this task, the DECarray cabinet is supplied with the SF Family Label
Booklet, with the rest of the literature found with the cabinet. Follow the instructions found inside the front cover of the booklet.
Configuring, Cabling, and Labeling the DECarray Cabinet 4–7
Configuring, Cabling, and Labeling the DECarray Cabinet
4.3 DECarray Cabinet and Cable Labels
4.3.1 Completing the System Configuration Sheet
At this time, fill out the system configuration sheet. Blank configuration worksheets are provided in the appendix of this manual.
Note
Do not attempt to fill out and place the labels until you have completed the system configuration sheet.
The information from the system configuration sheet is used to fill out the labels correctly for all DSSI cables, enclosure OCPs, and magazine tape ISEs.
You can also refer to the inside cover of the SF Family Label Booklet (36–
32882–01) for instructions on how to fill out the labels.
4.3.2 Filling Out the Labels (Single-System)
The labels are available in two sizes; the larger one for the DSSI cables and the smaller one for the storage enclosure and the system I/O panel.
Proceed once you have filled out the cable and OCP labels according to the instructions on the inside cover of the SF Family Label Booklet (36–32882–01).
4.3.3 Placing the Labels (Single-System)
Once the labels have been filled out, place them on the DSSI cables and the storage enclosures. Also place a label on the front of the magazine tape ISE.
On the DSSI cable, place the label about four inches behind the DSSI connector
(Figure 4–9).
Place the SF7x OCP label as shown in Figure 4–10. The SF3x OCP does not have a place to affix a label.
Place the magazine tape ISE label as shown in Figure 4–11.
4–8 Configuring, Cabling, and Labeling the DECarray Cabinet
Configuring, Cabling, and Labeling the DECarray Cabinet
4.3 DECarray Cabinet and Cable Labels
Figure 4–9 Placing a Label on a DSSI Cable
L A B E L
S H R - X 0 1 0 8 - 9 0
Figure 4–10 Placing a Label on the SF7x Storage Enclosure
d i g i t a l
Ready
Write
Protect
Fault
DSSI
ID
DSSI
ID
Ready
Write
Protect
Fault
1
2
NNnNN
S H R _ X 1 1 2 8 C _ 8 9
Configuring, Cabling, and Labeling the DECarray Cabinet 4–9
Configuring, Cabling, and Labeling the DECarray Cabinet
4.3 DECarray Cabinet and Cable Labels
Figure 4–11 Placing a Label on the Magazine Tape ISE
O P E R A T O R C O N T R O L P A N E L
E j e c t
L o a d / U n l o a d
S l o t S e l e c t
D S S I
N O D E
I D L A B E L
P o w e r O n
W r i t e
P r o t e c t e d
T a p e I n U s e
U s e
C l e a n i n g T a p e
M a g a z i n e
F a u l t
L o a d e r F a u l t
0
W r i t e P r o t e c t
L o a d F a u l t 1
2
3
4
5
6
4 0 % R E D U C T I O N
E j e c t
L o a d / U n l o a d
S l o t S e l e c t
P o w e r O n
W r i t e
P r o t e c t e d
T a p e I n U s e
H e a d C l e a n
I n d i c a t o r
D r i v e F a u l t
L o a d e r F a u l t
S H R _ X 1 0 2 5 C _ 8 9
4–10 Configuring, Cabling, and Labeling the DECarray Cabinet
Configuring, Cabling, and Labeling the DECarray Cabinet
4.4 Powering Up the DECarray Cabinet (Single-System)
4.4 Powering Up the DECarray Cabinet (Single-System)
Once the DECarray cabinet has been installed and labeled, you are ready to apply power. Follow these steps in order.
CAUTION
Ensure that the ac power switch on each storage enclosure and magazine tape ISE installed is in the off position.
1. At the rear of the DECarray cabinet, turn the power controller on. Ensure that the BUS/OFF/ON switch is in the ON (left) position (Figure 4–12).
2. Apply power to each magazine tape ISE installed. Observe the front panels. If a failure occurs, refer to the Tape ISE Owners Manual.
3. Apply power to each storage enclosure, starting with position one and continuing in numerical order.
4. Press the dc power switch for each ISE in each storage enclosure. Start with position one and continue in numerical order. If the Fault indicator lights for any disk ISE, refer to the disk ISE owners manual.
5. Observe the OCP indicators.
For SF3x Storage Enclosures:
a. Check that all dc power buttons are lit for all ISEs installed in the rear of the storage enclosure. After about 15 seconds they will flicker, indicating power-on self-tests.
b. Check that all dc power buttons are lit for all ISEs installed in the front of the storage enclosure. Power is applied to the front ISEs approximately 30 seconds after the rear ISEs. About 15 seconds after power is applied, the buttons flicker, indicating power-on self-tests.
c. Check that all Fault indicators on the OCP are off. If a Fault indicator is lit green or amber, press the switch. If a Fault indicator is lit red, it indicates a faulty ISE.
For SF7x Storage Enclosures:
a. Check that the TERM PWR indicator (behind the door of the OCP) is on for all positions installed.
b. Check that the SPLIT indicator (behind the door of the OCP) is on for positions three and eight only.
Configuring, Cabling, and Labeling the DECarray Cabinet 4–11
Configuring, Cabling, and Labeling the DECarray Cabinet
4.4 Powering Up the DECarray Cabinet (Single-System)
6. Press the Ready button on the OCP. The Ready indicator flickers, then lights steadily green once the ISE is on line.
Figure 4–12 Power Controller Circuit Breaker
GROMMETED
CORD
OPENING
DELAYED
(0.5 SEC)
UNDELAYED
POWER CONTROL
BUS CONNECTORS
JI3 JI2 J11 J10
BUS/OFF/ON SWITCH
(SYMBOLS CLOCKWISE FROM RIGHT)
O
CB
I
FUSE
LABEL
881
CIRCUIT
BREAKER
POWER CORD
STRAIN RELIEF
POWER
CORD
CXO-3527A-TI
4–12 Configuring, Cabling, and Labeling the DECarray Cabinet
Configuring, Cabling, and Labeling the DECarray Cabinet
4.4 Powering Up the DECarray Cabinet (Single-System)
4.4.1 Single-System Final Verification
Once the hardware installation, cabling and labeling, and the powering up steps are complete, you are ready to configure the DSSI subsystem and verify the correct operation of each ISE in the array with the system.
Refer to the KFMSA or KFQSA Module Installation and User Manuals for detailed information on the correct operation of each ISE. In these manuals, you will find the procedure for establishing the communications between the
ISEs, the adapter module, and the system. You will also find the step-by-step procedures for reconfiguring the system with its newly installed DSSI devices.
Refer to the manuals for the disk ISE and tape ISE for detailed information on the local programs in the ISEs.
Once the verification is complete, close the cabinet doors; turn the hex-Allen fasteners one half turn clockwise to lock. The system is ready to be turned over to the system manager.
4.5 Installing Add-On Storage Elements
Perform the add-on installation only after installation steps required in
Chapter 3 have been completed.
Digital Services or trained installers must perform these procedures. Ensure that all precautions for site preparation have been completed. Refer to
Chapter 2 for information on site preparation. Detailed instructions for add-on installations are included in Chapter 5, Section 6.1 and Chapter 7.
WARNING
Hazardous voltages are in the SF400 DECarray cabinet and in the components of the cabinet. When performing any operation involving the power source(s), turn the power controls of all storage elements and power controller(s) to the off position. Then disconnect the power cables from the source outlets. Perform the operation, then reconnect the power cable(s) to the source(s).
Configuring, Cabling, and Labeling the DECarray Cabinet 4–13
Configuring, Cabling, and Labeling the DECarray Cabinet
4.5 Installing Add-On Storage Elements
CAUTION
This DECarray cabinet may have two power controller power cords.
To reduce the risk of electric shock, disconnect power source(s) before servicing.
To completely remove power from the equipment, disconnect the two power controller power cords from their source(s).
To remove power from an individual storage device inside the equipment, disconnect the individual power supply cord at the storage element.
To remove power from an individual power controller, disconnect the external power supply cord supplying the power controller.
4.5.1 Add-On Configuration Overview
The SF400 DECarray cabinet will accept add-on storage elements up to the maximum number of one half rack storage devices that will completely fill the cabinet. Storage elements must be added in the manner described in this chapter in order to adhere to safety and human factors considerations.
WARNING
Failure to comply with recommended storage element loading rules could result in an unstable SF400 DECarray cabinet. Cabinet instability could result in serious damage to the cabinet and installed storage elements, or serious personal injury.
4.5.2 Typical Add-On Configurations
The SF400 DECarray cabinet is loaded with add-on storage units consisting of
RF7x disk drives, RF3x disk drives and TF8x7 magazine tape systems. Any combination of these storage units, up to the maximum number of each device the cabinet can hold, may be installed into the cabinet.
4–14 Configuring, Cabling, and Labeling the DECarray Cabinet
Configuring, Cabling, and Labeling the DECarray Cabinet
4.5 Installing Add-On Storage Elements
4.5.2.1 SF400 DECarray Cabinet Locations
Figure 4–13 shows the position numbers for storage units loaded into the
SF400 DECarray cabinet.
Note
Position numbers 1 through 10 refer to cabinet loading positions only and do not imply the loading sequence for any storage device.
4.5.3 Configuration Rules
You must follow these configuration rules when adding on storage enclosures to the SF400 DECarray cabinet:
1. Load all TFxxx tape drives first.
2. Load all SF7x storage enclosures next, by load order, into slots not used by tapes.
3. Load all SF3x enclosures next, by load order, into slots not occupied by
TFxxx tape drives or SF7x enclosures.
4. Configure SF7x enclosures with four drives as through-bus boxes
5. Add terminators, if required, if there are no split-bus SF7x enclosures in the cab.
6. Configure SF7x enclosures with two drives as split-bus boxes.
7. Refer to the SF3x User’s Guide for configuration rules.
Configuring, Cabling, and Labeling the DECarray Cabinet 4–15
Configuring, Cabling, and Labeling the DECarray Cabinet
4.5 Installing Add-On Storage Elements
Figure 4–13 Cabinet Loading Positions (Front View)
10
8
6
4
2
5
3
1
9
7
POWER
CONTROLLER
CXO-3528A-TI
4–16 Configuring, Cabling, and Labeling the DECarray Cabinet
Configuring, Cabling, and Labeling the DECarray Cabinet
4.5 Installing Add-On Storage Elements
Table 4–2 shows the proper loading sequence for disk and tape ISEs. Note that space for an add-on power controller is provided in the lower portion of the cabinet. If necessary, the add-on controller is installed in the front of the cabinet.
Table 4–2 Loading Sequences
Tapes
5–6
7–8
SFxx Storage Enclosures
3–4
5–6
1–2
7–8
9–10
Power
Controllers
Rear (first)
Front (second)
4.5.4 Installing Dual Power Controllers
A factory installed power controller is included with every SF400 DECarray cabinet. The factory installed power controller is always located at the rear of the DECarray cabinet. Digital offers an upgrade kit to those customers that want to upgrade their SF400 DECarray cabinet to dual power controllers.
The second add-on upgrade power controller is always located at the front of the DECarray cabinet. Follow the installation instructions included with the upgrade kit to install the power controller.
Power controller upgrade kits are ordered by specifying the following Digital option numbers:
• SF400–UA for 120/208 volt 50/60 Hz
• SF400–UD for 380/415 volt 50/60 Hz
Configuring, Cabling, and Labeling the DECarray Cabinet 4–17
5
Installing the Magazine Tape ISE in a
DECarray Cabinet
This chapter describes how to install the magazine tape ISE in a DECarray cabinet. The following procedures are described:
• Steps for installing the magazine tape ISE (Section 5.1)
• Cabling (Section 5.8)
• Power up (Section 5.9)
• Labeling (Section 5.10)
• Final verification (Section 5.11)
One or two magazine tape ISEs can be installed in the DECarray cabinet.
Only Digital Services and other installing personnel that have been trained in
ESD procedures can use the procedures in this chapter.
Table 5–1 lists the tools required to install the magazine tape ISE into the
DECarray cabinet.
Table 5–1 Magazine Tape ISE Required Tool List
Description Part Number
#0 Phillips screwdriver
#1 Phillips screwdriver
#2 Phillips screwdriver
1/8-inch slot screwdriver
5/16-inch slot screwdriver
1/8-inch hex key
29–10991–00
29–11001–00
29–11005–00
29–10802–00
29–10960–00
29–26115–00
(continued on next page)
Installing the Magazine Tape ISE in a DECarray Cabinet
5–1
Installing the Magazine Tape ISE in a DECarray Cabinet
Table 5–1 (Cont.) Magazine Tape ISE Required Tool List
Description Part Number
3/16-inch hex key
11/32-inch nutdriver
29–26118–00
29–10674–00
5.1 Steps for Installing the Magazine Tape ISE
The magazine tape ISE that you are installing contains a tape ISE and the tape cartridge loader assemblies.
This section contains several major steps. The first step explains how to:
• Unpack, inspect for damage, and identify parts
• Determine where to install the magazine tape ISE
• Read and fill out the system configuration sheet
The next step explains how to install the magazine tape ISE:
• Prepare the array cabinet to receive a magazine tape ISE
• Install the supporting hardware and magazine tape ISE, and set the DSSI node ID switches
• Cable the magazine tape ISE to comply with the DSSI bus cabling conventions
The last step explains how to:
• Power up the magazine tape ISE, run the power-on self-test, and run the configuration programs
• Label all cables and operator control panels
• Verify the operation of the enclosure after a successful installation
Follow all the steps in the order they are presented and do not skip any steps.
5.1.1 Unpacking the Magazine Tape ISE
The magazine tape ISE is shipped in an environmental barrier bag with desiccant, the container, and all packing materials.
Note
After unpacking, retain the container and all packing materials.
5–2 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.1 Steps for Installing the Magazine Tape ISE
Examine the subsystem for physical damage. If you find any damage, do not attempt to install the subsystem. Notify your local sales office immediately.
If there is no damage, then unpack all the boxes and bags, and identify all the parts by using Table 5–2.
Table 5–2 Magazine Tape ISE Required Mounting Hardware
Description
Tape bezel kit (optional)
Magazine tape ISE ac power cord, 8-foot
Owner’s manual
Label booklet
Locktite, screw lock
White DSSI cable, BC21Q–3F
Cable tie
1
1
1
1 as req.
1
4
Quantity Part Number
1 70–29768–01
CK–SF400–TE
ISE specific
17–00442–03
EK–TF857–OM
36–32882–01
90–09321–00
17–02382-01
90–07032-00
Chassis Rail Hardware
Chassis rail
Rail bracket
Nut bar
Nut bar
Round standoff
Flat head screw, 10-32
Shoulder screw, 10-32, 0.438
Lockwasher, internal tooth
Screw, Phillips pan, 10-32 (SEMS)
U-nut for SEMS screws
6
6
4
2
4
6
2
1
1
1
Lockdown bracket
Lockdown bracket
Chassis Retainer Hardware
1
1
74–45635–02
74–45647–02
74–45637–02
74–36464–01
90–10830–02
90–00039–26
12–24007–02
90–06637–00
12–21368–02
90–07786–00
74–44472–01
74–44472–02
(continued on next page)
Installing the Magazine Tape ISE in a DECarray Cabinet
5–3
Installing the Magazine Tape ISE in a DECarray Cabinet
5.1 Steps for Installing the Magazine Tape ISE
Table 5–2 (Cont.) Magazine Tape ISE Required Mounting Hardware
Chassis Retainer Hardware
Cap screw, 10-32 hex, 1.50
Cap screw, 10-32 hex, 0.375
U-nut for cap screws
Lockwasher
Flatwasher
6
2
2
4
2
90–06352–08
90–06345–08
90–07786–00
90–07906–00
90–06664–00
Note
The magazine tape requires the Tape Bezel Kit, Digital option number
CK–SF400–TE, Digital part number 70–29768–01.
5.1.2 Where to Install the Magazine Tape ISE
The configuration rules in Section 5.1.2.1 explain where to install the magazine tape ISE. It is important to adhere to these configuration rules to maintain optimum weight balance and stabilization of the DECarray cabinet.
5.1.2.1 Configuration Rules
You must follow these configuration rules when adding on storage enclosures to the SF400 DECarray cabinet:
1. Load all tapes first.
2. Load all SFxx storage enclosures next, by load order, into slots not used by tapes.
3. Load SF7x enclosures before SF3x enclosures.
4. Configure SF7x enclosures with four drives as through-bus and cable to tape drive. Add terminator if no split-bus boxes in cab.
5. Configure SF7x enclosures with two drives as split-bus and cable to available through-bus SF7x enclosures.
6. Configure SF3x enclosures.
5–4 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.1 Steps for Installing the Magazine Tape ISE
Table 5–3 shows the proper loading sequence for disk and tape ISEs. Note that space for an add-on power controller is provided in the lower portion of the cabinet. If necessary, the add-on controller is installed in the front of the cabinet.
Table 5–3 Loading Sequences
Tapes
5–6
7–8
SFxx Storage Enclosures
3–4
5–6
1–2
7–8
9–10
Power
Controllers
Rear
Front
5.2 Installing TF8x7-Series Tape Drives
The TF8x7-series tape drive is mounted in the SF400 DECarray cabinet with one chassis rail, as shown in Figure 5–1. The chassis rail is attached to the cabinet’s internal vertical rails, and it supports the TF8x7-series tape drive from one side. Grooves machined into the side of the tape drive enclosure mate with flanges along the sides of the chassis rail, allowing the tape drive to be slid onto the chassis rail from the front of the cabinet. Once installed, the tape drive enclosure extends from the front to the rear of the SF400 DECarray cabinet.
Two TF8x7-series tape drives can be mounted side-by-side at a given vertical position in the cabinet. The chassis rail hardware is the same for both the left and right mounting positions. Only the orientation of the hardware differs between the two mounting positions. There is no mechanical connection between two tape drives mounted side-by-side in the cabinet.
In situations where only one TF8x7-series tape drive is being installed at a given vertical position in the cabinet, the tape drive must be installed in the right mounting position. This will ensure that the front panel of the tape drive mates with the correct opening in the tape bezel in the cabinet door. A filler panel in the door covers the left mounting position in this case.
Installing the Magazine Tape ISE in a DECarray Cabinet
5–5
Installing the Magazine Tape ISE in a DECarray Cabinet
5.2 Installing TF8x7-Series Tape Drives
WARNING
While working in the cabinet interior, ac power must be removed from cabinet components. Failure to do so may result in personnel injury as a result of electric shock.
Prior to performing any of the procedures in this chapter, remove ac power from cabinet components. If the cabinet is installed and operating, spin down all disk drives and halt all tape drives in the cabinet. Switch the circuit breaker on the front panel of the cabinet’s CDU(s) to the (OFF) position.
5–6 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.2 Installing TF8x7-Series Tape Drives
Figure 5–1 TF8x7-Series Tape Drive Installation
CABINET
TAPE
BEZEL
CHASSIS
RAIL
TF8x7-SERIES
(LEFT POSITION)
TF8x7-SERIES
(RIGHT POSITION)
CXO-3961A-MC
Installing the Magazine Tape ISE in a DECarray Cabinet
5–7
Installing the Magazine Tape ISE in a DECarray Cabinet
5.2 Installing TF8x7-Series Tape Drives
5.2.1 Accessing the Cabinet Rack Space
TF8x7-series tape drives can normally be installed without removing cabinet side panels. To route the cabling in configurations where access to the interior of the cabinet is limited, however, cabinet side panels may need to be removed.
Section 5.2.2 and 5.7 present procedures for removing and replacing exterior cabinet panels.
The front and rear cabinet doors are held closed by door locks mounted on each door. The locks are released by turning counterclockwise with a 5/32-inch hex wrench.
5.2.2 Removing the Cabinet Side Panels
As shown in Figure 5–2, there are three side panel hanger clips on each side of the cabinet. A matching set of hanger clips are attached to each side panel.
Remove the side panels as follows:
1. Move the cabinet away from adjacent enclosures as necessary.
2. Loosen the top cover by pushing up on its front and rear edges until it snaps free of its fasteners.
WARNING
The top cover is heavy and awkward to lift. Removing it is a twoperson task. Failure to use sufficient personnel may result in injury or equipment damage.
3. Using two persons, lift the top cover from the cabinet and set it aside.
4. Remove the bolts attaching the side panels to the top side rails of the cabinet.
5. Grasp a panel along its front and rear edges and lift up until the hanger clips disengage. Lift the panel away from the cabinet.
6. Repeat the previous step to remove the other panel.
5–8 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.2 Installing TF8x7-Series Tape Drives
Figure 5–2 Cabinet Side Panel Removal and Installation
NYLON SNAP
FASTENER
(4 PLACES)
FASTENER
PIN
(4 PLACES)
LIP
UPPER
SIDE PANEL
HANGER
CLIP
TOP COVER
M6x40mm BOLT
(4 PLACES)
SIDE PANEL
HANGER
CLIPS
LOWER
SIDE PANEL
HANGER
CLIPS
CABINET
FRONT
SIDE PANEL
CXO-3964A-MC
Installing the Magazine Tape ISE in a DECarray Cabinet
5–9
Installing the Magazine Tape ISE in a DECarray Cabinet
5.3 Chassis Rail Installation
5.3 Chassis Rail Installation
To allow the length of the chassis rail to be adjusted to fit the cabinet, one end of the rail is extendible using a sliding rail bracket. Two round standoffs are used to locate the chassis rail along the vertical cabinet rails. The round standoffs are inserted into front and rear chassis rail locating holes to position the chassis rail while it is fastened to the cabinet.
Note
Standoff location holes, front and rear, both sides, are holes 3, 15, 27,
39, and 51 as shown in Figure 5–3.
Note
Two small ESD grounding posts are provided with the cabinet. One is located on a front vertical cabinet rail, and one on a rear rail. Should an ESD grounding post interfere with the installation of the chassis rail, move the post out of the way to any free hole on the cabinet.
5.3.1 Chassis Rail Assembly
Before the chassis rail components can be mounted in the cabinet, they must be assembled. Assemble the chassis rail components as follows (see Figure 5–4):
1. Position the rail bracket against the chassis rail, as shown in the illustration.
2. Fasten the rail bracket to the chassis rail with the unbeveled nut bar and 4 screws, as shown. Leave the screws loose enough to allow the rail bracket to be moved along the chassis rail.
3. Install a U-nut in the groove near the end of each of the beveled nut bars.
The flat side of the U-nuts must be on the beveled side of the nut bar.
4. Install the beveled nut bars on the chassis rail and rail bracket, using the round standoffs to hold them in place. The beveled side of the nut bars must face the flanges on the chassis rail and rail bracket.
5. The chassis rail assembly is now ready to be installed in the cabinet.
5–10 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.3 Chassis Rail Installation
Figure 5–3 Cabinet Frame Mounting Hole Locations
Installing the Magazine Tape ISE in a DECarray Cabinet
5–11
Installing the Magazine Tape ISE in a DECarray Cabinet
5.3 Chassis Rail Installation
Figure 5–4 Chassis Rail Assembly
ROUND
STANDOFF
U-NUT, 10-32
(2 PLACES)
NUT BAR,
UNBEVELED
CHASSIS
RAIL
UP
SCREW, 10-32
FH
(4 PLACES)
NUT BAR,
BEVELED
(2 PLACES)
ROUND
STANDOFF
RAIL
BRACKET
CXO-3934A-MC
5–12 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.3 Chassis Rail Installation
5.3.2 Right Position Chassis Rail Assembly Installation
Install the chassis rail assembly in the right position within the cabinet as follows (see Figure 5–5):
WARNING
Cabinet rail edges may be sharp and can slice or abrade skin or cable insulation.
1. Turn the cabinet power off as described in Section 5.2.
2. Determine the correct tape drive mounting locations and corresponding cabinet rail mounting holes for the chassis rail assembly. Refer to the chapter in this document pertaining to your specific cabinet configuration for this information. The tape mounting hole specified for each position is the chassis rail locating hole shown in Figure 5–5.
WARNING
Use care in supporting the chassis rail assembly. It is heavy and awkward to position within the cabinet. If possible, use two persons to support and position the chassis rail assembly. The chassis rail assembly may cause personnel injury and equipment damage if dropped during installation.
Note
To ensure proper alignment of the chassis rail assembly, use care to position the round standoffs in the correct front and rear chassis rail locating holes.
3. From the front of the cabinet, position the chassis rail assembly at the correct mounting holes, as shown. Ensure that the rail bracket is positioned toward the front of the cabinet, and that the arrow on the rail bracket points up.
Installing the Magazine Tape ISE in a DECarray Cabinet
5–13
Installing the Magazine Tape ISE in a DECarray Cabinet
5.3 Chassis Rail Installation
Figure 5–5 Right Position Chassis Rail Installation
REAR VERTICAL
CABINET RAIL
REAR
CHASSIS
RAIL
LOCATING
HOLE
ROUND
STANDOFF
(2 PLACES)
INNER
FLANGE
U-NUT, 10-32
(4 PLACES)
INNER
FLANGE
FRONT VERTICAL
CABINET RAIL
OUTER
FLANGE
U-NUT, 10-32
(2 PLACES)
FRONT
CHASSIS
RAIL
LOCATING
HOLE
UP
SCREW, 10-32
SEMS
(4 PLACES)
CHASSIS
RAIL ASSEMBLY
RAIL
BRACKET
WASHER, LOCK
10-32, INTERNAL
(6 PLACES)
SCREW, 10-32
HEX CAP
(6 PLACES)
4. Insert the rear round standoff into the rear chassis rail locating hole.
5. Support the chassis rail against the rear vertical cabinet rail and maintain the rear round standoff in its locating hole. Extend the rail bracket to insert the front round standoff into its correct front chassis rail locating hole.
6. Using the shelf bracket as a template, mark the four U-nut mounting holes on the inner flanges of both the front and rear vertical cabinet rails. Make sure to use the correct set of holes in the chassis rail.
CXO-3924A-MC
5–14 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.3 Chassis Rail Installation
7. Temporarily remove the chassis rail assembly and install four U-nuts along the inner flanges of the front and rear vertical cabinet rails at the holes marked in step 6.
8. Reposition the chassis rail assembly as directed in steps 3 through 5.
9. Fasten the chassis rail to the inner flanges of the front and rear vertical cabinet rails with 4 screws, as shown.
10. Fasten the rail bracket to the front vertical cabinet rail with its beveled nut bar and three screws, as shown.
11. Fasten the chassis rail to the rear vertical cabinet rail with its beveled nut bar and three screws, as shown.
12. Tighten the screws fastening the rail bracket to the chassis rail.
13. Install two U-nuts along the outer flange of the front vertical cabinet rail.
Install one U-nut at the hole just above the front chassis rail locating hole and the other at the eighth hole below the locating hole.
5.3.3 Left Position Chassis Rail Assembly Installation
Note
Install the chassis rail assembly in the left mounting position only if a tape drive is also installed in the right position. The tape bezel openings are designed to allow a single tape drive to be installed only in the right position.
Install the chassis rail assembly in the left position within the cabinet as follows (see Figure 5–6):
WARNING
Cabinet rail edges may be sharp and can slice or abrade skin or cable insulation.
1. Turn the cabinet power off as described in Section 5.2.
2. Determine the correct tape drive mounting locations and corresponding cabinet rail mounting holes for the chassis rail assembly. Refer to the chapter in this document pertaining to your specific cabinet configuration for this information. The tape mounting hole specified for each position is the chassis rail locating hole shown in Figure 5–6.
Installing the Magazine Tape ISE in a DECarray Cabinet
5–15
Installing the Magazine Tape ISE in a DECarray Cabinet
5.3 Chassis Rail Installation
WARNING
Use care in supporting the chassis rail assembly. It is heavy and awkward to position within the cabinet. If possible, use two persons to support and position the chassis rail assembly. The chassis rail assembly may cause personnel injury and equipment damage if dropped during installation.
Note
To ensure proper alignment of the chassis rail assembly, use care to position the round standoffs in the correct front and rear chassis rail locating holes.
3. From the rear of the cabinet, position the chassis rail assembly at the correct mounting holes, as shown. Ensure that the rail bracket is positioned toward the rear of the cabinet, and that the arrow on the rail bracket points up.
4. Insert the front round standoff into the front chassis rail locating hole.
5. Support the chassis rail assembly against the front vertical cabinet rail and maintain the front round standoff in its locating hole. Extend the rail bracket to insert the rear round standoff into its correct rear chassis rail locating hole.
6. Using the chassis rail as a template, mark the four U-nut mounting holes on the inner flanges of both the front and rear vertical cabinet rails. Make sure to use the correct set of holes in the chassis rail.
7. Temporarily remove the chassis rail assembly and install four U-nuts along the inner flanges of the front and rear vertical cabinet rails at the holes marked in step 6.
8. Reposition the chassis rail assembly as directed in steps 3 through 5.
9. Fasten the chassis rail assembly to the inner flanges of the front and rear vertical cabinet rails with 4 screws, as shown.
5–16 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.3 Chassis Rail Installation
Figure 5–6 Left Position Chassis Rail Assembly Installation
REAR VERTICAL
CABINET RAIL
OUTER
FLANGE
FRONT VERTICAL
CABINET RAIL
INNER
FLANGE
U-NUT, 10-32
(2 PLACES)
U-NUT, 10-32
(4 PLACES)
FRONT
CHASSIS
RAIL
LOCATING
HOLE
INNER
FLANGE
REAR
CHASSIS
RAIL
LOCATING
HOLE
ROUND
STANDOFF
(2 PLACES)
UP
RAIL
BRACKET
WASHER, LOCK
10-32, INTERNAL
(6 PLACES)
SCREW, 10-32
HEX CAP
(6 PLACES)
CHASSIS
RAIL ASSEMBLY
SCREW, 10-32
SEMS
(4 PLACES)
10. Fasten the rail bracket to the rear vertical cabinet rail with its beveled nut bar and three screws, as shown.
11. Fasten the chassis rail to the front vertical cabinet rail with its beveled nut bar and three screws, as shown.
12. Tighten the screws fastening the rail bracket to the chassis rail.
13. Install two U-nuts along the outer flange of the front vertical cabinet rail.
Install one U-nut at the hole just above the front chassis rail locating hole and the other at the eighth hole below the locating hole.
CXO-3923A-MC
Installing the Magazine Tape ISE in a DECarray Cabinet
5–17
Installing the Magazine Tape ISE in a DECarray Cabinet
5.4 Mounting the TF8x7-Series Tape Drive Enclosure
5.4 Mounting the TF8x7-Series Tape Drive Enclosure
Once the chassis rail is installed in the cabinet, the tape drive enclosure can be mounted on it. Mount the TF8x7-series tape drive to the chassis rail as follows:
Note
The lock down brackets are mirror images of each other, and they are identified as the -01 and -02 versions. They must be installed with the orientation shown in the illustration.
1. Install the the two lock down brackets on the side of the tape drive enclosure near the front end, as shown in either Figure 5–7 or 5–8.
Figure 5–7 shows the installation for the right mounting position, and
Figure 5–8 shows the installation for the left mounting position.
WARNING
Use two persons to lift the TF8x7-series tape drive. The unit is heavy and awkward to lift. Failure to use two persons to lift the tape drive may result in injury or damage to equipment.
2. From the front of the cabinet and using two persons, position the tape drive such that the machined grooves in the side of the tape drive enclosure mate with the upper and lower edges of the chassis rail.
CAUTION
Use care when sliding the tape drive into the cabinet. Do not allow the tape drive enclosure to pull or pinch cables that may be routed through the cabinet interior. Failure to use care when mounting the tape drive may result in equipment damage.
3. Slide the tape drive onto the chassis rail until the lockdown brackets contact the U-nuts on the front vertical cabinet rail.
4. Fasten the lock down brackets to the front vertical chassis rail with two hex cap screws, as shown in Figure 5–7 or 5–8.
5–18 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.4 Mounting the TF8x7-Series Tape Drive Enclosure
Figure 5–7 Right Position Tape Drive Mounting
SCREW, 10-32
HEX CAP
(4 PLACES)
WASHER, 10-32
LOCK
(2 PLACES)
WASHER, 10-32
FLAT
(2 PLACES)
LOCK DOWN
BRACKET
(-02)
FRONT VERTICAL
CHASSIS RAIL
U-NUT, 10-32
(2 PLACES)
(REF)
TAPE DRIVE
ENCLOSURE
(FRONT)
LOCK DOWN
BRACKET
(-01)
WASHER, 10-32
LOCK
(4 PLACES)
SCREW, 10-32
HEX CAP
(4 PLACES)
NOTE: TAPE DRIVE INTERNAL COMPONENTS NOT SHOWN FOR CLARITY.
CXO-3918A-MC
Installing the Magazine Tape ISE in a DECarray Cabinet
5–19
Installing the Magazine Tape ISE in a DECarray Cabinet
5.4 Mounting the TF8x7-Series Tape Drive Enclosure
Figure 5–8 Left Position Tape Drive Mounting
FRONT VERTICAL
CABINET RAIL
LOCK DOWN
BRACKET
(-01)
WASHER, 10-32
FLAT
(2 PLACES)
WASHER, 10-32
LOCK
(2 PLACES)
SCREW, 10-32
HEX CAP
(2 PLACES)
U-NUT, 10-32
(2 PLACES)
(REF)
TAPE DRIVE
ENCLOSURE
(FRONT)
LOCK DOWN
BRACKET
(-02)
SCREW, 10-32
HEX CAP
(4 PLACES)
WASHER, 10-32
LOCK
(4 PLACES)
NOTE: TAPE DRIVE INTERNAL COMPONENTS NOT SHOWN FOR CLARITY.
CXO-3919A-MC
5–20 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.5 Installing the Power Cord
5.5 Installing the Power Cord
Perform the following steps completely and in the order presented.
CAUTION
Before performing the following steps, refer to the system documentation for the correct steps to perform an orderly shutdown of the system to which the DECarray cabinet is connected.
1. Install the ac power cord.
2. Connect the male end of the ac power cord to the the power controller as shown in Figure Figure 5–9. Refer to Table 5–4 if the DECarray cabinet is equipped with a single power controller. Refer to Table 5–5 if the
DECarray cabinet is equipped with dual power controllers.
Proper connection of ac power cords will ensure proper balancing of power distribution across all three phases of ac power. In both tables, device/position refers to cabinet positions 1 through 10.
Table 5–4 AC Power Distribution (Single Power Controller)
Phase
1
AC
Outlet ‡
J0
J1
J2
J3
Device/
Position
4
2
1
3
Label
A
A
A
A
2 J4
J5
J6
3 J7
J8
J9
‡ Power Controller AC outlet.
10
8
6
9
7
5
A
A
A
A
A
A
Installing the Magazine Tape ISE in a DECarray Cabinet
5–21
Installing the Magazine Tape ISE in a DECarray Cabinet
5.5 Installing the Power Cord
Figure 5–9 AC Power Switch, Voltage Selections, and Power Cord
D S S I
C O N N E C T O R S
A C P O W E R
S W I T C H
A C R E C E P T A C L E
S H R - X 0 1 4 1 B - 9 0 - C P G
5–22 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.5 Installing the Power Cord
Table 5–5 AC Power Distribution (Dual Power Controllers)
Phase
AC
Outlet ‡ Device/Position Label
First Power Controller (Rear)
1 J0
J1
J2
J3
2 open open
4
A
A
A 2 J4
J5
J6
10 open open
3 J7
J8
J9
8 open
6
Second Power Controller (Front)
1 J0
J1
J2
J3
1 open open
3
2 J4
J5
J6
9 open open
3 J7
J8
J9
‡ Power Controller AC outlet.
7 open
5
B
B
B
B
A
A
B
Installing the Magazine Tape ISE in a DECarray Cabinet
5–23
Installing the Magazine Tape ISE in a DECarray Cabinet
5.5 Installing the Power Cord
3. Check the factory set ac power on the rear of the SF7x enclosure. There are two model variants:
1. Model AA is 110 to 120 Vac
2. Model AB is 220 to 240 Vac
Note
Do not apply power at this time. Check to ensure that the factory set ac power is correct for your site. Call your Digital service representative if the factory set ac power is incorrect.
4. Refer to the TF857 Magazine Tape Subsystem Owners Manual, for operation and setup and configuration of the tape ISE.
5.6 Installing the Cabinet Door Tape Bezel Kit
To allow operator access to the TF8x7 tape drive, the front cabinet door tape bezel kit must be installed. To install the tape bezel kit, see the Instructions
for Installation of the Tape Bezel Kit on SF400 DECarray Cabinets provided with the kit.
5.7 Reinstalling Exterior Cabinet Panels
Once the cabinet rack space is configured as desired, the exterior cabinet panels may be reinstalled. Refer to Figure 5–2 and reinstall the exterior cabinet panels as follows:
1. Position a side panel against the cabinet with the lip above the upper hanger clips just over the upper edge of the side of the cabinet.
2. Ensure that the entire surface of the side panel rests firmly against the side of the cabinet.
3. Allow the panel to slide downward, catching the three hanger clips as it moves.
4. Install the side panel bolts into the side panel through the holes in the top side rails of the cabinet.
5. Repeat steps 1 through 4 to install the other side panel.
5–24 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.7 Reinstalling Exterior Cabinet Panels
6. Locate the four inset nylon snap fasteners on the top cabinet rails.
WARNING
The top cover is heavy and awkward to lift. Installing it is a twoperson task. Failure to use sufficient personnel may result in injury or equipment damage.
7. Position the top cover over the cabinet. Position the cover as shown in
Figure 5–2 such that the end of the panel with the shorter overhang is oriented toward the front of the cabinet.
8. Align the pins on the underside of the top cover with the inset nylon fasteners on the top cabinet rails.
WARNING
Be careful not to catch your fingers between the cabinet and the top panel when snapping the panel to the cabinet.
9. Lower the cover onto the cabinet and press it down, ensuring that the pins snap into the top panel fasteners.
10. If the cabinet was moved to access the side panels, place it in its original position.
5.8 Cabling the Magazine Tape ISE
This section describes the step-by-step procedure for cabling the magazine tape
ISE to the existing DSSI bus configuration of the DECarray cabinet.
Figure 5–10 shows the possible single-system configurations.
Installing the Magazine Tape ISE in a DECarray Cabinet
5–25
Installing the Magazine Tape ISE in a DECarray Cabinet
5.8 Cabling the Magazine Tape ISE
Figure 5–10 Typical Single-System Bus Configurations
S Y S
A
3 0 0 - i n c h B C 2 1 Q - 2 5
M a g a z i n e
T a p e
I S E
T
4 2 - i n c h
B C 2 1 Q - 3 F
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
S Y S
A
3 0 0 - i n c h B C 2 1 Q - 2 5
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
C X O - 3 5 4 7 A - T I
The following procedures assume that all devices installed previous to a new installation of a TF8X7 tape are cabled in the single-system configuration. For additional information on tape installation refer to Chapter 3.
WARNING
Before performing the following steps, refer to the system documentation for the correct procedure to perform an orderly shutdown of the system in which the DECarray cabinet is connected.
The following steps are for cabling a storage enclosure with a magazine tape
ISE:
1. Tighten the shipping screw in the rear, upper right corner, of the magazine tape ISE.
2. Remove the DSSI terminator from the bottom DSSI connector on the rear of the magazine tape ISE.
3. Install a 42-inch DSSI cable (BC21Q–3F) in the bottom DSSI connector on the rear of the magazine tape ISE.
4. Loosen the shipping screw in the rear, upper right corner, of the magazine tape ISE.
5. Pull the inner assembly of the magazine tape ISE out to the head cleaning position (first mechanical stop).
5–26 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.8 Cabling the Magazine Tape ISE
6. Route the DSSI cable to the nearest vertical rail and tie wrap.
7. Remove the two screws that hold the cable tray of the SF3x enclosure in place and slide the cable tray out to expose the four DSSI connectors.
8. Connect the 42-inch DSSI cable from the bottom DSSI connector of the magazine tape ISE to the rightmost DSSI connector for the rear ISEs in the SF3x storage enclosure.
9. If applicable, connect the 42-inch DSSI cable from the bottom DSSI connector of the magazine tape ISE to the rightmost DSSI connector for the front ISEs in the SF3x storage enclosure.
10. Install a DSSI terminator in the leftmost DSSI connector in the cable tray
(P2 for the rear ISEs and P4 for the front ISEs).
11. Slide the cable tray back into place and tighten the two screws.
12. Install an external DSSI cable from the top connector of the magazine tape
ISE to the appropriate KFMSA module.
CAUTION
Do not apply power to the magazine tape ISE at this time.
5.9 Powering Up the Magazine Tape ISE
Follow these steps to apply power to a newly installed magazine tape ISE.
1. Turn the ac power switch on the rear of the magazine tape ISE to the on position.
a. All of the OCP indicators turn on (generally within 15 seconds).
b. While the elevator scans the magazine, all OCP indicators, except for
Power On, turn off.
c. Assuming the ISE has a magazine with a cartridge in position zero, and no cartridge is in the drive, the final power-on self-test (POST) status displays:
Power On indicator on
Eject indicator on
Load/Unload indicator on
Slot Select indicator on
Slot 0 indicator on
Installing the Magazine Tape ISE in a DECarray Cabinet
5–27
Installing the Magazine Tape ISE in a DECarray Cabinet
5.9 Powering Up the Magazine Tape ISE
2. If a fault occurs, refer to the Magazine Tape ISE service manual.
Proceed to Section 5.9.1 once these steps are accomplished and the magazine tape ISE has passed POST.
5.9.1 Updating the System Configuration Sheet
Once the magazine tape ISE has been successfully installed, power has been applied, and the drives have passed POST, you are ready to update the system configuration sheet.
Refer to the KFMSA Module Installation and User Manual (EK–KFMSA–IM) for complete details on filling out a system configuration sheet.
5.9.2 Completing the System Configuration Sheet
Locate the system configuration sheet. If you cannot locate this sheet or if the one that is available is either not filled out or filled out incorrectly, fill one out before continuing with the installation procedure.
Figures 5–11 and 5–12 show examples of the system configuration sheet.
5–28 Installing the Magazine Tape ISE in a DECarray Cabinet
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Installing the Magazine Tape ISE in a DECarray Cabinet
5.9 Powering Up the Magazine Tape ISE
Figure 5–11 System Configuration Sheet (Single-System)
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
KFMSA/Single−System Configuration Sheet
[for VAX 6000 and 9000 systems]
Bus
DSSI ID #
KFMSA XMI Node #
Bus
DSSI ID #
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Color Code
Color Code
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM config_shr−x0109.rags
Installing the Magazine Tape ISE in a DECarray Cabinet
5–29
Installing the Magazine Tape ISE in a DECarray Cabinet
5.9 Powering Up the Magazine Tape ISE
Figure 5–12 System Configuration Sheet (Dual-System)
K F M S A / D S S I V A X c l u s t e r C o n f i g u r a t i o n S h e e t
B u s
D S S I I D #
B u s
D S S I I D #
K F M S A X M I N o d e #
K F M S A X M I N o d e #
B u s
D S S I I D #
B u s
D S S I I D #
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
M A - 0 4 2 7 - 9 2 . D G
5–30 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.10 Labeling the DSSI Cables and Magazine Tape ISE
5.10 Labeling the DSSI Cables and Magazine Tape ISE
Refer to the inside cover of the SF Family Label Booklet (36–32882–01) for instructions on filling out the labels.
5.10.1 Labeling the Cables
For each cable installed, place a label four inches behind the connector as shown in Figure 5–13.
Figure 5–13 Placing a Label on a DSSI Cable
L A B E L
S H R - X 0 1 0 8 - 9 0
5.10.2 Labeling the Magazine Tape ISE
Place the labels for the front panel of the magazine tape ISE as shown in
Figure 5–14.
Installing the Magazine Tape ISE in a DECarray Cabinet
5–31
Installing the Magazine Tape ISE in a DECarray Cabinet
5.10 Labeling the DSSI Cables and Magazine Tape ISE
Figure 5–14 Placing a Label on the Magazine Tape ISE
O P E R A T O R C O N T R O L P A N E L
E j e c t
L o a d / U n l o a d
S l o t S e l e c t
D S S I
N O D E
I D L A B E L
P o w e r O n
W r i t e
P r o t e c t e d
T a p e I n U s e
U s e
C l e a n i n g T a p e
M a g a z i n e
F a u l t
L o a d e r F a u l t
0
W r i t e P r o t e c t
L o a d F a u l t 1
2
3
4
5
6
4 0 % R E D U C T I O N
E j e c t
L o a d / U n l o a d
S l o t S e l e c t
P o w e r O n
W r i t e
P r o t e c t e d
T a p e I n U s e
H e a d C l e a n
I n d i c a t o r
D r i v e F a u l t
L o a d e r F a u l t
S H R _ X 1 0 2 5 C _ 8 9
5–32 Installing the Magazine Tape ISE in a DECarray Cabinet
Installing the Magazine Tape ISE in a DECarray Cabinet
5.11 Final Verification
5.11 Final Verification
Once the hardware installation, cabling and labeling, and the powering up steps are complete, you are ready to configure the DSSI subsystem and verify the correct operation of each ISE in the array with the host system.
Refer to the KFMSA Module Installation and User Manual (EK–KFMSA–IM) for detailed information on the correct operation of each ISE. In these manuals, you will find the procedure for establishing the communications between the
ISEs, the adapter module, and the system. You will also find the step-by-step procedures for reconfiguring the system with its newly installed DSSI devices.
Refer to the manuals for the disk ISE and magazine tape ISE for detailed information on the local programs in the ISEs.
If at any time you detect a failure, refer to the Magazine Tape ISE service manual.
Once the verification is complete, close the cabinet doors; turn the hex-Allen fasteners one half turn clockwise to lock. The system is ready to be turned over to the system manager.
Installing the Magazine Tape ISE in a DECarray Cabinet
5–33
6
Installing the SF7x Storage Enclosure in a
DECarray Cabinet
This chapter describes how to install the SF7x storage enclosure in a
DECarray cabinet. The following procedures are described:
• Steps for installing the SF7x storage enclosure (Section 6.1)
• Cabling (Section 6.8)
• Powering Up (Section 6.9)
• Labeling (Section 5.10.2)
• Final verification (Section 6.11)
Only Digital Services and other installing personnel that have been trained in
ESD procedures can use the procedures in this chapter.
Table 6–1 lists the tools required to install the SF7x storage enclosure into the
DECarray cabinet.
Table 6–1 SF7x Storage Enclosure Required Tool List
Description
#0 Phillips screwdriver
#1 Phillips screwdriver
#2 Phillips screwdriver
1/8-inch slot screwdriver
5/16-inch slot screwdriver
Part Number
29–10991–00
29–11001–00
29–11005–00
29–10802–00
29–10960–00
(continued on next page)
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–1
Installing the SF7x Storage Enclosure in a DECarray Cabinet
Table 6–1 (Cont.) SF7x Storage Enclosure Required Tool List
Description Part Number
1/8-inch hex key
3/16-inch hex key
11/32-inch nutdriver
29–26115–00
29–26118–00
29–10674–00
6.1 Steps for Installing the SF7x Storage Enclosure
This section contains several major steps. The first step explains how to:
• Unpack, inspect for damage, and identify parts
• Determine where to install the SF7x storage enclosure
• Read and fill out the system configuration sheet
The next step explains how to install the SF7x storage enclosure:
• Prepare the array cabinet to receive an SF7x storage enclosure
• Install the supporting hardware and SF7x storage enclosure, and set the
DSSI node ID switches
• Cable the SF7x storage enclosure to comply with the DSSI bus cabling conventions
The last step explains how to:
• Power up the SF7x storage enclosure, run the power-on self-test, and run the configuration programs
• Label all cables and operator control panels
• Verify the operation of the enclosure after a successful installation
Follow all the steps in the order they are presented and do not skip any steps.
6.1.1 Unpacking the SF7x Storage Enclosure
The SF7x storage enclosure is shipped in an environmental barrier bag with desiccant, the container, and all packing materials.
Note
After unpacking, retain the container and all packing materials.
6–2 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.1 Steps for Installing the SF7x Storage Enclosure
Examine the subsystem for physical damage. If you find any damage, do not attempt to install the subsystem. Notify your office immediately.
If there is no damage, unpack all the boxes and bags, and identify all the parts by using Table 6–2.
Table 6–2 Storage Enclosure Mounting Hardware Kit
Description
SF7x storage enclosure ac power cord, 8-foot
Owner’s manual
Label booklet
Locktite, screw lock
White DSSI cable, BC21Q–3F
Cable tie
Quantity Part Number
1
1
1
1 as req.
1
4
ISE specific
17–00442–03
EK–SF7x–OM
36–32882–01
90–09321–00
17–02382-01
90–07032-00
Chassis Rail Hardware
Chassis rail
Rail bracket
Nut bar
Nut bar
Round standoff
Flat head screw, 10-32
Shoulder screw, 10-32, 0.438
Lockwasher, internal tooth
Screw, Phillips pan, 10-32 (SEMS)
U-nut for SEMS screws
4
6
1
2
1
1
2
6
4
6
74–45635–02
74–45647–02
74–45637–02
74–36464–01
90–10830–02
90–00039–26
12–24007–02
90–06637–00
12–21368–02
90–07786–00
Lockdown bracket
Lockdown bracket
Cap screw, 10-32 hex, 1.50
Cap screw, 10-32 hex, 0.375
Chassis Retainer Hardware
1
1
2
4
74–44472–01
74–44472–02
90–06352–08
90–06345–08
(continued on next page)
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–3
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.1 Steps for Installing the SF7x Storage Enclosure
Table 6–2 (Cont.) Storage Enclosure Mounting Hardware Kit
Chassis Retainer Hardware
U-nut for cap screws
Lockwasher
Flatwasher
2
6
2
90–07786–00
90–07906–00
90–06664–00
6.1.2 Where to Install the SF7x Storage Enclosure
The configuration rules in Section 6.1.2.1 explain where to install the SF7x storage enclosure. It is important to adhere to these configuration rules to maintain optimum weight balance and stabilization of the DECarray cabinet.
6.1.2.1 Configuration Rules
You must follow these configuration rules when adding on storage enclosures to the SF400 DECarray cabinet:
1. Load all tapes first.
2. Load all SFxx storage enclosures next, by load order, into slots not used by tapes.
3. Load SF7x enclosures before SF3x enclosures.
4. Configure SF7x enclosures with four drives as through-bus and cable to tape drive.
Add terminator if no split-bus boxes in cab.
5. Configure SF7x enclosures with two drives as split-bus and cable to available through-bus SF7x enclosures.
6. Configure SF3x enclosures.
Table 6–3 shows the proper loading sequence for disk and tape ISEs. Note that space for an add-on power controller is provided in the lower portion of the cabinet. If necessary, the add-on controller is installed in the front of the cabinet.
6–4 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.1 Steps for Installing the SF7x Storage Enclosure
Table 6–3 Loading Sequences
Tapes
5–6
7–8
3–4
SFxx Storage Enclosures
3–4
5–6
1–2
7–8
9–10
Power
Controllers
Rear
Front
6.2 Installation Procedure
The SF7x storage enclosure is mounted in the SF400 DECarray cabinet with the chassis rail, as shown in Figure 6–1. The chassis rail is attached to the cabinet’s internal vertical rails, and it supports the SF7x enclosure from one side. Grooves machined into the side of the enclosure mate with flanges along the sides of the chassis rail, allowing the enclosure to be slid onto the chassis rail from the front of the cabinet. Once installed, the SF7x enclosure extends from the front to the rear of the SF400 DECarray cabinet.
Two SF7x enclosures can be mounted side-by-side at a given vertical position in the cabinet. The chassis rail hardware is the same for both the left and right mounting positions. Only the orientation of the hardware differs between the two mounting positions. There is no mechanical connection between two
SF7x enclosures mounted side-by-side in the cabinet.
In situations where only one SF7x enclosure is being installed at a given vertical position in the cabinet, the enclosure must be installed in the right mounting position. This will ensure that the front panel of the enclosure mates with the correct opening in the bezel in the cabinet door. A filler panel in the door covers the left mounting position in this case.
WARNING
While working in the cabinet interior, ac power must be removed from cabinet components. Failure to do so may result in personnel injury as a result of electric shock.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–5
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.2 Installation Procedure
Figure 6–1 SF7x Storage Enclosure Installation
CABINET
TAPE
BEZEL
CHASSIS
RAIL
SF7x-SERIES
(LEFT POSITION)
SF7x-SERIES
(RIGHT POSITION)
6–6 Installing the SF7x Storage Enclosure in a DECarray Cabinet
CXO-3965A-MC
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.2 Installation Procedure
Prior to performing any of the procedures in this chapter, remove ac power from cabinet components. If the cabinet is installed and operating, spin down all disk drives and halt all tape drives in the cabinet. Switch the circuit breaker on the front panel of the cabinet’s CDU(s) to the (OFF) position.
6.2.1 Accessing the Cabinet Rack Space
SF7x enclosures can normally be installed without removing cabinet side panels. To route the cabling in configurations where access to the interior of the cabinet is limited, however, cabinet side panels may need to be removed.
Section 6.2.2 presents procedures for removing and replacing exterior cabinet panels.
The front and rear cabinet doors are held closed by door locks mounted on each door. The locks are released by turning counterclockwise with a 5/32-inch hex wrench.
6.2.2 Removing the Cabinet Side Panels
As shown in Figure 6–2, there are three side panel hanger clips on each side of the cabinet. A matching set of hanger clips are attached to each side panel.
Remove the side panels as follows:
1. Move the cabinet away from adjacent enclosures as necessary.
2. Loosen the top cover by pushing up on its front and rear edges until it snaps free of its fasteners.
WARNING
The top cover is heavy and awkward to lift. Removing it is a twoperson task. Failure to use sufficient personnel may result in injury or equipment damage.
3. Using two persons, lift the top cover from the cabinet and set it aside.
4. Remove the bolts attaching the side panels to the top side rails of the cabinet.
5. Grasp a panel along its front and rear edges and lift up until the hanger clips disengage. Lift the panel away from the cabinet.
6. Repeat the previous step to remove the other panel.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–7
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.2 Installation Procedure
Figure 6–2 Cabinet Side Panel Removal and Installation
NYLON SNAP
FASTENER
(4 PLACES)
FASTENER
PIN
(4 PLACES)
LIP
UPPER
SIDE PANEL
HANGER
CLIP
TOP COVER
M6x40mm BOLT
(4 PLACES)
SIDE PANEL
HANGER
CLIPS
LOWER
SIDE PANEL
HANGER
CLIPS
CABINET
FRONT
SIDE PANEL
6–8 Installing the SF7x Storage Enclosure in a DECarray Cabinet
CXO-3964A-MC
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.3 Chassis Rail Installation
6.3 Chassis Rail Installation
To allow the length of the chassis rail to be adjusted to fit the cabinet, one end of the rail is extendible using a sliding rail bracket. Two round standoffs are used to locate the chassis rail along the vertical cabinet rails. The round standoffs are inserted into front and rear chassis rail locating holes to position the chassis rail while it is fastened to the cabinet.
Note
Standoff location holes, front and rear, both sides, are holes 3, 15, 27,
39, and 51 as shown in Figure 6–3.
Note
Two small ESD grounding posts are provided with the cabinet. One is located on a front vertical cabinet rail, and one on a rear rail. Should an ESD grounding post interfere with the installation of the chassis rail, move the post out of the way to any free hole on the cabinet.
6.3.1 Chassis Rail Assembly
Before the chassis rail components can be mounted in the cabinet, they must be assembled. Assemble the chassis rail components as follows (see Figure 6–4):
1. Position the rail bracket against the chassis rail, as shown in the illustration.
2. Fasten the rail bracket to the chassis rail with the unbeveled nut bar and 4 screws, as shown. Leave the screws loose enough to allow the rail bracket to be moved along the chassis rail.
3. Install a U-nut in the groove near the end of each of the beveled nut bars.
The flat side of the U-nuts must be on the beveled side of the nut bar.
4. Install the beveled nut bars on the chassis rail and rail bracket, using the round standoffs to hold them in place. The beveled side of the nut bars must face the flanges on the chassis rail and rail bracket.
5. The chassis rail assembly is now ready to be installed in the cabinet.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–9
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.3 Chassis Rail Installation
Figure 6–3 Cabinet Frame Mounting Hole Locations
6–10 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.3 Chassis Rail Installation
Figure 6–4 Chassis Rail Assembly
ROUND
STANDOFF
U-NUT, 10-32
(2 PLACES)
NUT BAR,
UNBEVELED
UP
CHASSIS
RAIL
SCREW, 10-32
FH
(4 PLACES)
ROUND
STANDOFF
NUT BAR,
BEVELED
(2 PLACES)
RAIL
BRACKET
CXO-3934A-MC
6.3.2 Right Position Chassis Rail Assembly Installation
Install the chassis rail assembly in the right position within the cabinet as follows (see Figure 6–5):
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–11
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.3 Chassis Rail Installation
WARNING
Cabinet rail edges may be sharp and can slice or abrade skin or cable insulation.
1. Turn the cabinet power off as described in Section 6.2.
2. Determine the correct enclosure mounting locations and corresponding cabinet rail mounting holes for the chassis rail assembly. Refer to the chapter in this document pertaining to your specific cabinet configuration for this information. The enclosure mounting hole specified for each position is the chassis rail locating hole shown in Figure 6–5.
WARNING
Use care in supporting the chassis rail assembly. It is heavy and awkward to position within the cabinet. If possible, use two persons to support and position the chassis rail assembly. The chassis rail assembly may cause personnel injury and equipment damage if dropped during installation.
Note
To ensure proper alignment of the chassis rail assembly, use care to position the round standoffs in the correct front and rear chassis rail locating holes.
3. From the front of the cabinet, position the chassis rail assembly at the correct mounting holes, as shown. Ensure that the rail bracket is positioned toward the front of the cabinet, and that the arrow on the rail bracket points up.
4. Insert the rear round standoff into the rear chassis rail locating hole.
5. Support the chassis rail against the rear vertical cabinet rail and maintain the rear round standoff in its locating hole. Extend the rail bracket to insert the front round standoff into its correct front chassis rail locating hole.
6–12 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.3 Chassis Rail Installation
Figure 6–5 Right Position Chassis Rail Installation
REAR VERTICAL
CABINET RAIL
REAR
CHASSIS
RAIL
LOCATING
HOLE
ROUND
STANDOFF
(2 PLACES)
INNER
FLANGE
U-NUT, 10-32
(4 PLACES)
INNER
FLANGE
FRONT VERTICAL
CABINET RAIL
OUTER
FLANGE
U-NUT, 10-32
(2 PLACES)
FRONT
CHASSIS
RAIL
LOCATING
HOLE
UP
SCREW, 10-32
SEMS
(4 PLACES)
CHASSIS
RAIL ASSEMBLY
RAIL
BRACKET
WASHER, LOCK
10-32, INTERNAL
(6 PLACES)
SCREW, 10-32
HEX CAP
(6 PLACES)
6. Using the shelf bracket as a template, mark the four U-nut mounting holes on the inner flanges of both the front and rear vertical cabinet rails. Make sure to use the correct set of holes in the chassis rail.
7. Temporarily remove the chassis rail assembly and install four U-nuts along the inner flanges of the front and rear vertical cabinet rails at the holes marked in step 6.
8. Reposition the chassis rail assembly as directed in steps 3 through 5.
CXO-3924A-MC
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–13
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.3 Chassis Rail Installation
9. Fasten the chassis rail to the inner flanges of the front and rear vertical cabinet rails with 4 screws, as shown.
10. Fasten the rail bracket to the front vertical cabinet rail with its beveled nut bar and three screws, as shown.
11. Fasten the chassis rail to the rear vertical cabinet rail with its beveled nut bar and three screws, as shown.
12. Tighten the screws fastening the rail bracket to the chassis rail.
13. Install two U-nuts along the outer flange of the front vertical cabinet rail.
Install one U-nut at the hole just above the front chassis rail locating hole and the other at the eighth hole below the locating hole.
6.3.3 Left Position Chassis Rail Assembly Installation
Note
Install the chassis rail assembly in the left mounting position only if an enclosure is also installed in the right position. The bezel openings are designed to allow a single enclosure to be installed only in the right position.
Install the chassis rail assembly in the left position within the cabinet as follows (see Figure 6–6):
WARNING
Cabinet rail edges may be sharp and can slice or abrade skin or cable insulation.
1. Turn the cabinet power off as described in Section 6.2.
2. Determine the correct enclosure mounting locations and corresponding cabinet rail mounting holes for the chassis rail assembly. Refer to the chapter in this document pertaining to your specific cabinet configuration for this information. The enclosure mounting hole specified for each position is the chassis rail locating hole shown in Figure 6–6.
6–14 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.3 Chassis Rail Installation
WARNING
Use care in supporting the chassis rail assembly. It is heavy and awkward to position within the cabinet. If possible, use two persons to support and position the chassis rail assembly. The chassis rail assembly may cause personnel injury and equipment damage if dropped during installation.
Note
To ensure proper alignment of the chassis rail assembly, use care to position the round standoffs in the correct front and rear chassis rail locating holes.
3. From the rear of the cabinet, position the chassis rail assembly at the correct mounting holes, as shown. Ensure that the rail bracket is positioned toward the rear of the cabinet, and that the arrow on the rail bracket points up.
4. Insert the front round standoff into the front chassis rail locating hole.
5. Support the chassis rail assembly against the front vertical cabinet rail and maintain the front round standoff in its locating hole. Extend the rail bracket to insert the rear round standoff into its correct rear chassis rail locating hole.
6. Using the chassis rail as a template, mark the four U-nut mounting holes on the inner flanges of both the front and rear vertical cabinet rails. Make sure to use the correct set of holes in the chassis rail.
7. Temporarily remove the chassis rail assembly and install four U-nuts along the inner flanges of the front and rear vertical cabinet rails at the holes marked in step 6.
8. Reposition the chassis rail assembly as directed in steps 3 through 5.
9. Fasten the chassis rail assembly to the inner flanges of the front and rear vertical cabinet rails with 4 screws, as shown.
10. Fasten the rail bracket to the rear vertical cabinet rail with its beveled nut bar and three screws, as shown.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–15
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.3 Chassis Rail Installation
Figure 6–6 Left Position Chassis Rail Assembly Installation
REAR VERTICAL
CABINET RAIL
OUTER
FLANGE
FRONT VERTICAL
CABINET RAIL
INNER
FLANGE
U-NUT, 10-32
(2 PLACES)
U-NUT, 10-32
(4 PLACES)
FRONT
CHASSIS
RAIL
LOCATING
HOLE
INNER
FLANGE
REAR
CHASSIS
RAIL
LOCATING
HOLE
ROUND
STANDOFF
(2 PLACES)
UP
RAIL
BRACKET
WASHER, LOCK
10-32, INTERNAL
(6 PLACES)
SCREW, 10-32
HEX CAP
(6 PLACES)
CHASSIS
RAIL ASSEMBLY
SCREW, 10-32
SEMS
(4 PLACES)
11. Fasten the chassis rail to the front vertical cabinet rail with its beveled nut bar and three screws, as shown.
12. Tighten the screws fastening the rail bracket to the chassis rail.
13. Install two U-nuts along the outer flange of the front vertical cabinet rail.
Install one U-nut at the hole just above the front chassis rail locating hole and the other at the eighth hole below the locating hole.
CXO-3923A-MC
6–16 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.4 Mounting the SF7x Storage Enclosure
6.4 Mounting the SF7x Storage Enclosure
Once the chassis rail is installed in the cabinet, the SF7x enclosure can be mounted on it. Mount the SF7x enclosure to the chassis rail as follows:
Note
The lock down brackets are mirror images of each other, and they are identified as the -01 and -02 versions. They must be installed with the orientation shown in the illustration.
1. Install the the two lock down brackets on the side of the SF7x enclosure near the front end, as shown in either Figure 6–7 or 6–8. Figure 6–7 shows the installation for the right mounting position, and Figure 6–8 shows the installation for the left mounting position.
WARNING
Use two persons to lift the SF7x enclosure. The unit is heavy and awkward to lift. Failure to use two persons to lift the enclosure may result in injury or damage to equipment.
2. From the front of the cabinet and using two persons, position the enclosure such that the machined grooves in the side of the enclosure mate with the upper and lower edges of the chassis rail.
CAUTION
Use care when sliding the enclosure into the cabinet. Do not allow the enclosure to pull or pinch cables that may be routed through the cabinet interior. Failure to use care when mounting the SF7x enclosure may result in equipment damage.
3. Slide the enclosure onto the chassis rail until the lockdown brackets contact the U-nuts on the front vertical cabinet rail.
4. Fasten the lock down brackets to the front vertical chassis rail with two hex cap screws, as shown in Figure 6–7 or 6–8.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–17
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.4 Mounting the SF7x Storage Enclosure
Figure 6–7 Right Position SF7x Enclosure Mounting
SCREW, 10-32
HEX CAP
(4 PLACES)
WASHER, 10-32
LOCK
(2 PLACES)
WASHER, 10-32
FLAT
(2 PLACES)
LOCK DOWN
BRACKET
(-02)
FRONT VERTICAL
CHASSIS RAIL
U-NUT, 10-32
(2 PLACES)
(REF)
TAPE DRIVE
ENCLOSURE
(FRONT)
LOCK DOWN
BRACKET
(-01)
WASHER, 10-32
LOCK
(4 PLACES)
SCREW, 10-32
HEX CAP
(4 PLACES)
NOTE: TAPE DRIVE INTERNAL COMPONENTS NOT SHOWN FOR CLARITY.
CXO-3918A-MC
6–18 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.4 Mounting the SF7x Storage Enclosure
Figure 6–8 Left Position SF7x Enclosure Mounting
FRONT VERTICAL
CABINET RAIL LOCK DOWN
BRACKET
(-01)
WASHER, 10-32
FLAT
(2 PLACES)
WASHER, 10-32
LOCK
(2 PLACES)
SCREW, 10-32
HEX CAP
(2 PLACES)
U-NUT, 10-32
(2 PLACES)
(REF)
TAPE DRIVE
ENCLOSURE
(FRONT)
LOCK DOWN
BRACKET
(-02)
SCREW, 10-32
HEX CAP
(4 PLACES)
WASHER, 10-32
LOCK
(4 PLACES)
NOTE: TAPE DRIVE INTERNAL COMPONENTS NOT SHOWN FOR CLARITY.
CXO-3919A-MC
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–19
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.5 Installing the Power Cord
6.5 Installing the Power Cord
Install the power cord within the cabinet as follows:
CAUTION
Before performing the following steps, refer to the system documentation for the correct steps to perform an orderly shutdown of the system to which the DECarray cabinet is connected.
1. Install the ac power cord.
2. Connect the male end of the ac power cord to the the power controller as shown in Figure Figure 6–9. Refer to Table 6–4 if the DECarray cabinet is equipped with a single power controller. Refer to Table 6–5 if the
DECarray cabinet is equipped with dual power controllers.
Proper connection of ac power cords will ensure proper balancing of power distribution across all three phases of ac power. In both tables, device/position refers to cabinet positions 1 through 10.
Table 6–4 AC Power Distribution (Single Power Controller)
Phase
1
AC
Outlet ‡
J0
J1
J2
J3
Device/
Position
4
2
1
3
Label
A
A
A
A
2 J4
J5
J6
3 J7
J8
J9
‡ Power Controller AC outlet.
10
8
6
9
7
5
A
A
A
A
A
A
6–20 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.5 Installing the Power Cord
Table 6–5 AC Power Distribution (Dual Power Controllers)
Phase
AC
Outlet ‡ Device/Position Label
First Power Controller (Rear)
1 J0
J1
J2
J3
2 open open
4
A
A
A 2 J4
J5
J6
10 open open
3 J7
J8
J9
8 open
6
Second Power Controller (Front)
1 J0
J1
J2
J3
1 open open
3
2 J4
J5
J6
9 open open
3 J7
J8
J9
‡ Power Controller AC outlet.
7 open
5
B
B
B
B
A
A
B
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–21
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.5 Installing the Power Cord
Figure 6–9 Power Connection and Voltage Selection
D S S I
C O N N E C T O R S
1 0
P O W E R S U P P L Y
F A U L T I N D I C A T O R
( B E H I N D P A N E L )
A C R E C E P T A C L E A C P O W E R
S W I T C H
L I N E V O L T A G E
S E L E C T O R S W I T C H
( B E H I N D P A N E L )
S H R - X 0 1 2 7 A - 9 0
3. Check the factory set ac power on the SF7x enclosure. There are two model variants:
1. Model AA is 110 to 120 Vac
2. Model AB is 220 to 240 Vac
6–22 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.5 Installing the Power Cord
Note
Do not apply power at this time. Check to ensure that the factory set ac power is correct for your site. Call your Digital service representative if the factory set ac power is incorrect.
4. Refer to the SF7x Owner’s Manual for operation and setup of the SF7x enclosure.
6.6 Configuring the SF7x Enclosure
1. Perform the following steps if you are installing an SF7x enclosure in a position requiring that the enclosure be configured for split-bus mode.
(single-system only):
CAUTION
To maintain stability, extend only one storage enclosure or magazine tape ISE on the slide mounts at a time.
a. Loosen the four captive slide assembly screws. Slide the inner assembly out until the drawer locks in the service position.
b. Push the inner assembly forward from the rear.
Note
Do NOT completely remove the inner drawer assembly from the extrusion tube and extend only one at a time.
c. Reconfigure the transition module (TTM) for split-bus mode by first moving the small black jumper to the split-bus terminals, then moving cable connectors to the right pair of sockets. Refer to Figure 6–10 and
Figure 6–11 to locate the TTM and jumper.
d. Push the SF7x inner drawer back in, replace the front cover door, and tighten the four front door screws.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–23
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.6 Configuring the SF7x Enclosure
Figure 6–10 Changing an SF7x Enclosure to Split-Bus Mode
S P L I T - B U S M O D E
J 5 J 4 J 3 J 2
T H R U
S P L I T
J 1 1
T O O C P
S H R _ X 1 1 1 1 _ 8 9
To prevent pinching any cables, be sure that all cables are dressed correctly.
2. Position the OCP.
a. Adjust the SF7x OCP mount (Figure 6–11) to the
LEFT for positions 1,
3, 5, 7, and 9. Adjust the SF7x OCP mount to the
RIGHT for positions
2, 4, 6, 8 and 10.
b. Check that this and all other OCP and magazine tape ISE fronts project through the front door of the DECarray cabinet correctly.
It may be necessary to adjust cabinet door mounting at the door hinges.
3. Check the DSSI ID switches on the OCP.
6–24 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.6 Configuring the SF7x Enclosure
Figure 6–11 Adjusting the OCP
SLOTTED
HOLE
HOLE FOR
RIGHT
POSITION
HOLE FOR
LEFT
POSITION
TRANSITION
BOARD
SCREWS
SLOTTED
HOLE
TRANSITION
BOARD
(BEHIND FRAME)
S H R - X 0 1 2 4 - 9 0
4. Open the door on the front of the OCP. Ensure that the DSSI ID switches
(the three rightmost switches) are set according to Figure 6–12. If they are not, then use a pointed instrument to set the switches to their correct configuration. Refer to Table 6–6.
Note
The leftmost switch (MSCP) should in the down or enabled position at all times, unless you are instructed to change it to the up or disabled position.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–25
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.6 Configuring the SF7x Enclosure
Figure 6–12 DSSI ID Switch Settings
d i g i t a l
Ready
Write
Protect
Fault
DSSI
ID
1
2
DSSI
ID
Ready
Write
Protect
Fault
S H R _ X 1 1 2 8 B _ 8 9
Table 6–6 DSSI ID Switch Settings (SF7x Only)
Positions 1, 2, 4, and 7
1
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
001
010
011
100
Positions 3 and 8 (single-system only)
1
1
The switch settings for OCPs in these positions are 0 = down and 1 = up.
(continued on next page)
6–26 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.6 Configuring the SF7x Enclosure
Table 6–6 (Cont.) DSSI ID Switch Settings (SF7x Only)
Positions 3 and 8 (single-system only)
1
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
1
101
110
110
101
The switch settings for OCPs in these positions are 0 = down and 1 = up.
CAUTION
Observe all ESD precautions and procedures.
5. Install the OCP (Figure 6–13).
Note
Make sure that the power is off to the enclosure.
Make sure that ALL the buttons are in the OUT position.
6. At the front of the SF7x enclosure, make sure that all four drive dc power switches are out (Figure 6–14).
7. At the rear of the SF7x enclosure, make sure that the ac power switch is in off or in the zero position (Figure 6–15).
8. Also check the select line voltage. Set it to the correct setting for your application.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–27
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.6 Configuring the SF7x Enclosure
Figure 6–13 Installing the OCP on the SF7x Enclosure
TTM CLIP
FASTENERS
FRONT
COVER
OPERATOR
CONTROL
PANEL
OCP
CONNECTOR
PINS
ESD
WRIST
STRAP
S H R _ X 1 1 1 3 _ 8 9 _ S C N
6–28 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.6 Configuring the SF7x Enclosure
9. At this time, connect the ac power cord to the SF7x enclosure.
Figure 6–14 Drive DC Power Switches
O P E R A T O R C O N T R O L P A N E L ( O C P ) d i g i t a l
Ready
Write
Protect Fault
DSSI
ID
DSSI
ID
Ready
Write
Protect
Fault
D R I V E D C P O W E R S W I T C H E S
M A - 0 4 2 9 - 9 2 . D G
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–29
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.7 Reinstalling Exterior Cabinet Panels
Figure 6–15 AC Power Switch, Voltage Selections, and Power Cord
D S S I
C O N N E C T O R S
1 0
P O W E R S U P P L Y
F A U L T I N D I C A T O R
( B E H I N D P A N E L )
A C R E C E P T A C L E A C P O W E R
S W I T C H
L I N E V O L T A G E
S E L E C T O R S W I T C H
( B E H I N D P A N E L )
S H R - X 0 1 2 7 A - 9 0
6.7 Reinstalling Exterior Cabinet Panels
Once the cabinet rack space is configured as desired, the exterior cabinet panels may be reinstalled. Refer to Figure 5–2 and reinstall the exterior cabinet panels as follows:
1. Position a side panel against the cabinet with the lip above the upper hanger clips just over the upper edge of the side of the cabinet.
2. Ensure that the entire surface of the side panel rests firmly against the side of the cabinet.
6–30 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.7 Reinstalling Exterior Cabinet Panels
3. Allow the panel to slide downward, catching the three hanger clips as it moves.
4. Install the side panel bolts into the side panel through the holes in the top side rails of the cabinet.
5. Repeat steps 1 through 4 to install the other side panel.
6. Locate the four inset nylon snap fasteners on the top cabinet rails.
WARNING
The top cover is heavy and awkward to lift. Installing it is a twoperson task. Failure to use sufficient personnel may result in injury or equipment damage.
7. Position the top cover over the cabinet. Position the cover as shown in
Figure 5–2 such that the end of the panel with the shorter overhang is oriented toward the front of the cabinet.
8. Align the pins on the underside of the top cover with the inset nylon fasteners on the top cabinet rails.
WARNING
Be careful not to catch your fingers between the cabinet and the top panel when snapping the panel to the cabinet.
9. Lower the cover onto the cabinet and press it down, ensuring that the pins snap into the top panel fasteners.
10. If the cabinet was moved to access the side panels, place it in its original position.
6.8 Cabling the SF7x Storage Enclosure
This section describes the step-by-step procedure for cabling the SF7x storage enclosure to the existing DSSI bus configuration of the DECarray cabinet
(Refer to Chapter 3 for additional cabling information).
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–31
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.8 Cabling the SF7x Storage Enclosure
Figure 6–16 shows the possible single-system configurations.
Figure 6–16 Typical Single-System Bus Configurations
S Y S
A
3 0 0 - i n c h B C 2 1 Q - 2 5
M a g a z i n e
T a p e
I S E
T
4 2 - i n c h
B C 2 1 Q - 3 F
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
S Y S
A
3 0 0 - i n c h B C 2 1 Q - 2 5
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
C X O - 3 5 4 7 A - T I
The following procedures assume that all devices installed previous to a new installation of an SF7x enclosure are cabled in the single-system configuration.
WARNING
Before performing the following steps, refer to the system documentation for the correct procedure to perform an orderly shutdown of the system in which the DECarray cabinet is connected.
The following steps are for cabling a SF7x storage enclosure:
1. Tighten the shipping screw in the rear, upper right corner, of the SF7x enclosure.
2. Remove the DSSI terminator from the bottom DSSI connector on the rear of the SF7x enclosure.
3. Install a 42-inch DSSI cable (BC21Q–3F) in the bottom DSSI connector on the rear of the SF7x enclosure.
4. Loosen the shipping screw in the rear, upper right corner, of the SF7x enclosure.
6–32 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.8 Cabling the SF7x Storage Enclosure
5. Pull the inner assembly of the SF7x enclosure out to the head cleaning position (first mechanical stop).
6. Route the DSSI cable to the nearest vertical rail and tie wrap.
7. Remove the two screws that hold the cable tray of the SF7x enclosure in place and slide the cable tray out to expose the four DSSI connectors.
8. Connect the 42-inch DSSI cable from the bottom DSSI connector of the
SF7x enclosure to the rightmost DSSI connector for the rear ISEs in the
SF7x storage enclosure.
9. If applicable, connect the 42-inch DSSI cable from the bottom DSSI connector of the SF7x enclosure to the rightmost DSSI connector for the front ISEs in the SF7x storage enclosure.
10. Install a DSSI terminator in the leftmost DSSI connector in the cable tray
(P2 for the rear ISEs and P4 for the front ISEs).
11. Slide the cable tray back into place and tighten the two screws.
12. Install an external DSSI cable from the top connector of the magazine tape
ISE to the appropriate KFMSA module.
CAUTION
Do not apply power to the SF7x storage enclosure at this time.
6.9 Powering Up the SF7x Storage Enclosure
Follow these steps to apply power to a newly installed SF7x storage enclosure:
1. Turn the ac power switch on the rear of the SF7x storage enclosure to the on position.
2. If a fault occurs, refer to the SF7x storage enclosure service manual.
Proceed to Section 6.9.1 once these steps are accomplished and the SF7x storage enclosure has passed POST.
6.9.1 Updating the System Configuration Sheet
Once the SF7x storage enclosure has been successfully installed, power has been applied, and the drives have passed POST, you are ready to update the system configuration sheet.
Refer to the KFMSA Module Installation and User Manual for complete details on filling out a system configuration sheet.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–33
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.9 Powering Up the SF7x Storage Enclosure
6.9.2 Completing the System Configuration Sheet
Locate the system configuration sheet. If you cannot locate this sheet or if the one that is available is either not filled out or filled out incorrectly, fill one out before continuing with the installation procedure. Figures 6–17 and 6–18 show examples of the system configuration sheet.
6–34 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.9 Powering Up the SF7x Storage Enclosure
Figure 6–17 System Configuration Sheet (Single-System)
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
KFMSA/Single−System Configuration Sheet
[for VAX 6000 and 9000 systems]
Bus
DSSI ID #
KFMSA XMI Node #
Bus
DSSI ID #
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Color Code
Color Code
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM config_shr−x0109.rags
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–35
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.9 Powering Up the SF7x Storage Enclosure
Figure 6–18 System Configuration Sheet (Dual-System)
K F M S A / D S S I V A X c l u s t e r C o n f i g u r a t i o n S h e e t
B u s
D S S I I D #
B u s
D S S I I D #
K F M S A X M I N o d e #
K F M S A X M I N o d e #
B u s
D S S I I D #
B u s
D S S I I D #
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
M A - 0 4 2 7 - 9 2 . D G
6–36 Installing the SF7x Storage Enclosure in a DECarray Cabinet
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.10 Labeling the DSSI Cables and SF7x Storage Enclosure
6.10 Labeling the DSSI Cables and SF7x Storage Enclosure
Refer to the inside cover of the SF Family Label Booklet for instructions on filling out the labels.
6.10.1 Labeling the Cables
For each cable installed, place a label four inches behind the connector as shown in Figure 6–19.
Figure 6–19 Placing a Label on a DSSI Cable
L A B E L
S H R - X 0 1 0 8 - 9 0
6.10.2 Labeling the SF7x Storage Enclosure
Place the labels on the OCP of the SF7x storage enclosure as shown in
Figure 6–20.
6.11 Final Verification
Once the hardware installation, cabling and labeling, and the powering up steps are complete, you are ready to configure the DSSI subsystem and verify the correct operation of each ISE in the array with the host system.
Refer to the KFMSA Module Installation and User Manual for detailed information on the correct operation of each ISE. In these manuals, you will find the procedure for establishing the communications between the ISEs, the adapter module, and the system. You will also find the step-by-step procedures for reconfiguring the system with its newly installed DSSI devices.
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6–37
Installing the SF7x Storage Enclosure in a DECarray Cabinet
6.11 Final Verification
Figure 6–20 Placing a Label on the SF7x Storage Enclosure
d i g i t a l
Ready
Write
Protect
Fault
DSSI
ID
DSSI
ID
Ready
Write
Protect
Fault
1
2
NNnNN
S H R _ X 1 1 2 8 C _ 8 9
Refer to the manuals for the disk ISE and magazine tape ISE for detailed information on the local programs in the ISEs.
If at any time you detect a failure, refer to The SF7x owners manual.
Once the verification is complete, close the cabinet doors; turn the hex-Allen fasteners one half turn clockwise to lock. The system is ready to be turned over to the system manager.
6–38 Installing the SF7x Storage Enclosure in a DECarray Cabinet
7
Installing the SF3x Storage Enclosure in a
DECarray Cabinet
This chapter describes the add-on installation of the SF3x storage enclosure into a DECarray cabinet. The SF3x storage enclosure that you are installing may contain two, six, or twelve RF3x disk ISEs.
These procedures assume that the DECarray has previously been correctly installed and configured.
Only Digital Services or other personnel that have been trained in ESD procedures should perform the installation.
Table 7–1 lists the tools required to install the SF3x enclosure into the
DECarray cabinet.
Table 7–1 SF3x Required Tool List
Description
Lifting device
#0 Phillips screwdriver
#1 Phillips screwdriver
#2 Phillips screwdriver
1/8-inch slot screwdriver
5/16-inch slot screwdriver
1/8-inch hex key
3/16-inch hex key
11/32-inch nutdriver
Part Number
FC–10117–AC
29–10991–00
29–11001–00
29–11005–00
29–10802–00
29–10960–00
29–26115–00
29–26118–00
29–10674–00
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–1
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.1 Unpacking the SF3x Storage Enclosure
7.1 Unpacking the SF3x Storage Enclosure
Unpack the SF3x shipping container. The enclosure is shipped in an environmental barrier bag.
Note
After unpacking, retain the container and all packing materials.
Examine the enclosure for physical damage. If you find any damage, do not attempt to install the enclosure. Notify your office immediately.
If there is no damage, then unpack all the boxes and bags, and identify all the parts by using Table 7–2.
Table 7–2 SF3x Kit Contents
Description
SF3x storage enclosure ac power cord, 8-foot
Owner’s manual
Label booklet
Locktite, screw lock
White DSSI cable, BC21Q–3F
Cable tie
Chassis rail
Rail bracket
Nut bar
Nut bar
Round standoff
Flat head screw, 10-32
Shoulder screw, 10-32, 0.438
Chassis Rail Hardware
4
6
1
2
1
1
2
Quantity Part Number
1
1
1
1 as req.
1
4
SF3x–BK (2-drive)
SF3x–HK (6-drive)
SF3x–JK (12-drive)
17–00442–03
EK–SF3x–OM
36–32882–01
90–09321–00
17–02382-01
90–07032-00
74–45635–02
74–45647–02
74–45637–02
74–36464–01
90–10830–02
90–00039–26
12–24007–02
(continued on next page)
7–2 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.1 Unpacking the SF3x Storage Enclosure
Table 7–2 (Cont.) SF3x Kit Contents
Chassis Rail Hardware
Lockwasher, internal tooth
Screw, Phillips pan, 10-32 (SEMS)
U-nut for SEMS screws
6
4
6
Lockdown bracket
Lockdown bracket
Cap screw, 10-32 hex, 1.50
Cap screw, 10-32 hex, 0.500
U-nut for cap screws
Lockwasher
Flatwasher
Chassis Retainer Hardware
1
1
2
4
2
6
2
90–06637–00
12–21368–02
90–07786–00
74–44472–01
74–44472–02
90–06352–08
90–06345–08
90–07786–00
90–07906–00
90–06664–00
7.2 Where to Install the SF3x Storage Enclosure
Storage enclosures must be installed in the DECarray cabinet in accordance with the configuration rules listed in Section 4.5.3.
In split-bus mode, the ISEs occupying the left-side slots share a DSSI bus, and the ISEs occupying the right-side slots share a different DSSI bus. This is true for the front six ISEs and the rear six ISEs. Therefore, a fully-populated SF3x enclosure in split-bus mode will have four DSSI buses, each with three ISEs connected to it. Four DSSI adapter ports are required for each SF3x storage enclosure.
Figure 7–1 shows you where to install the enclosures in the DECarray cabinet.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–3
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.2 Where to Install the SF3x Storage Enclosure
Figure 7–1 DECarray Storage Enclosure Locations
10
8
6
4
2
5
3
1
9
7
POWER
CONTROLLER
7–4 Installing the SF3x Storage Enclosure in a DECarray Cabinet
CXO-3528A-TI
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.3 Checking the System Configuration Sheet
7.3 Checking the System Configuration Sheet
Locate the system configuration sheet. If you cannot locate this sheet or if the one that is available is either not filled out or filled out incorrectly, fill one out before continuing with the installation procedure. Blank configuration sheets are provided in Appendix A.
Figures 7–2 through 7–4 show examples of a system configuration sheet.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–5
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.3 Checking the System Configuration Sheet
Figure 7–2 Single-System Configuration Sheet
K F M S A / D S S I S i n g l e - s y s t e m C o n f i g u r a t i o n S h e e t
K F M S A X M I N o d e #
B u s 1
D S S I I D #
7
B u s 2
D S S I I D #
7
D e v i c e T y p e
D S S I I D #
N o d e N a m e
T a p e
0
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
5
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
1
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
2
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
3
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
T a p e
0
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
1
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
2
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
2
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
2
0
6
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
3
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
2
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
4
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
5
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
3
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
4
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
5
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
2
0
3
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
6
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
3
C o l o r C o d e o n C a b l e s
B l u e
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
6
S y s t e m I D
C o l o r C o d e o n C a b l e s
R e d
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
0
3
M A - 0 4 0 9 - 9 2 . D G
7–6 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.3 Checking the System Configuration Sheet
Figure 7–3 DSSI VAXcluster System Configuration Sheet (Two-System)
K F M S A / D S S I V A X c l u s t e r C o n f i g u r a t i o n S h e e t
B u s 1
D S S I I D #
6
B u s 2
D S S I I D #
6
K F M S A X M I N o d e #
K F M S A X M I N o d e #
B u s 1
D S S I I D #
7
B u s 2
D S S I I D #
7
D e v i c e T y p e
D S S I I D #
N o d e N a m e
T a p e
0
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
5
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
1
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
2
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
3
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
4
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
5
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
T a p e
0
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
6
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
1
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
2
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
3
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
4
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
5
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
M A - 0 4 1 0 - 9 2 . D G
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–7
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.3 Checking the System Configuration Sheet
Figure 7–4 DSSI VAXcluster System Configuration Sheet (Three-System)
B u s 1
D S S I I D #
5
B u s 2
D S S I I D #
K F M S A X M I N o d e #
5
B u s 1
D S S I I D #
6
B u s 2
D S S I I D #
K F M S A X M I N o d e #
6
D e v i c e T y p e
D S S I I D #
N o d e N a m e
T a p e
0
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
5
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
1
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
2
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
3
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
4
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
1
K F M S A X M I N o d e #
B u s 1
D S S I I D #
7
B u s 2
D S S I I D #
7
D e v i c e T y p e
D S S I I D #
N o d e N a m e
T a p e
0
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
6
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
1
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
2
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
3
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
D e v i c e T y p e
D S S I I D #
N o d e N a m e
R F 3 5
4
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
2
2
M A - 0 4 1 1 - 9 2 . D G
7–8 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.4 Installation Procedure
7.4 Installation Procedure
The SF3x storage enclosure is mounted in the SF400 DECarray cabinet with one chassis rail, as shown in Figure 7–5. The chassis rail is attached to the cabinet’s internal vertical rails, and it supports the SF3x enclosure from one side. Grooves machined into the side of the enclosure mate with flanges along the sides of the chassis rail, allowing the enclosure to be slid onto the chassis rail from the front of the cabinet. Once installed, the SF3x enclosure extends from the front to the rear of the SF400 DECarray cabinet.
Two SF3x enclosures can be mounted side-by-side at a given vertical position in the cabinet. The chassis rail hardware is the same for both the left and right mounting positions. Only the orientation of the hardware differs between the two mounting positions. There is no mechanical connection between two
SF3x enclosures mounted side-by-side in the cabinet.
In situations where only one SF3x enclosure is being installed at a given vertical position in the cabinet, the enclosure must be installed in the right mounting position. This will ensure that the front panel of the enclosure mates with the correct opening in the bezel in the cabinet door. A filler panel in the door covers the left mounting position in this case.
WARNING
While working in the cabinet interior, ac power must be removed from cabinet components. Failure to do so may result in personnel injury as a result of electric shock.
Prior to performing any of the procedures in this chapter, remove ac power from cabinet components. If the cabinet is installed and operating, spin down all disk drives and halt all tape drives in the cabinet. Switch the circuit breaker on the front panel of the cabinet’s CDU(s) to the OFF position.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–9
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.4 Installation Procedure
Figure 7–5 SF3x Storage Enclosure Installation
CABINET
TAPE
BEZEL
CHASSIS
RAIL
SF3x-SERIES
(LEFT POSITION)
SF3x-SERIES
(RIGHT POSITION)
7–10 Installing the SF3x Storage Enclosure in a DECarray Cabinet
CXO-3963A-MC
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.4 Installation Procedure
7.4.1 Accessing the Cabinet Rack Space
SF3x enclosures can normally be installed without removing cabinet side panels. To route the cabling in configurations where access to the interior of the cabinet is limited, however, cabinet side panels may need to be removed.
Section 7.4.2 presents procedures for removing and replacing exterior cabinet panels.
The front and rear cabinet doors are held closed by door locks mounted on each door. The locks are released by turning counterclockwise with a 5/32-inch hex wrench.
7.4.2 Removing the Cabinet Side Panels
As shown in Figure 7–6, there are three side panel hanger clips on each side of the cabinet. A matching set of hanger clips are attached to each side panel.
Remove the side panels as follows:
1. Move the cabinet away from adjacent enclosures as necessary.
2. Loosen the top cover by pushing up on its front and rear edges until it snaps free of its fasteners.
WARNING
The top cover is heavy and awkward to lift. Removing it is a twoperson task. Failure to use sufficient personnel may result in injury or equipment damage.
3. Using two persons, lift the top cover from the cabinet and set it aside.
4. Remove the bolts attaching the side panels to the top side rails of the cabinet.
5. Grasp a panel along its front and rear edges and lift up until the hanger clips disengage. Lift the panel away from the cabinet.
6. Repeat the previous step to remove the other panel.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–11
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.4 Installation Procedure
Figure 7–6 Cabinet Side Panel Removal and Installation
NYLON SNAP
FASTENER
(4 PLACES)
FASTENER
PIN
(4 PLACES)
LIP
UPPER
SIDE PANEL
HANGER
CLIP
TOP COVER
M6x40mm BOLT
(4 PLACES)
SIDE PANEL
HANGER
CLIPS
LOWER
SIDE PANEL
HANGER
CLIPS
CABINET
FRONT
SIDE PANEL
7–12 Installing the SF3x Storage Enclosure in a DECarray Cabinet
CXO-3964A-MC
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
7.5 Chassis Rail Installation
To allow the length of the chassis rail to be adjusted to fit the cabinet, one end of the rail is extendable using a sliding rail bracket. Two round standoffs are used to locate the chassis rail along the vertical cabinet rails. The round standoffs are inserted into front and rear chassis rail locating holes to position the chassis rail while it is fastened to the cabinet.
Note
Standoff location holes, front and rear, both sides, are holes 3, 15, 27,
39, and 51 as shown in Figure 7–7.
Note
Two small ESD grounding posts are provided with the cabinet. One is located on a front vertical cabinet rail, and one on a rear rail. Should an ESD grounding post interfere with the installation of the chassis rail, move the post out of the way to any free hole on the cabinet.
7.5.1 Chassis Rail Assembly
Before the chassis rail components can be mounted in the cabinet, they must be assembled. Assemble the chassis rail components as follows (see Figure 7–8):
1. Position the rail bracket against the chassis rail, as shown in the illustration.
2. Fasten the rail bracket to the chassis rail with the unbeveled nut bar and 4 screws, as shown. Leave the screws loose enough to allow the rail bracket to be moved along the chassis rail.
3. Install a U-nut in the groove near the end of each of the beveled nut bars.
The flat side of the U-nuts must be on the beveled side of the nut bar.
4. Install the beveled nut bars on the chassis rail and rail bracket, using the round standoffs to hold them in place. The beveled side of the nut bars must face the flanges on the chassis rail and rail bracket.
5. The chassis rail assembly is now ready to be installed in the cabinet.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–13
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
Figure 7–7 Cabinet Frame Mounting Hole Locations
7–14 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
Figure 7–8 Chassis Rail Assembly
ROUND
STANDOFF
U-NUT, 10-32
(2 PLACES)
NUT BAR,
UNBEVELED
UP
CHASSIS
RAIL
SCREW, 10-32
FH
(4 PLACES)
ROUND
STANDOFF
NUT BAR,
BEVELED
(2 PLACES)
RAIL
BRACKET
CXO-3934A-MC
7.5.2 Right Position Chassis Rail Assembly Installation
Install the chassis rail assembly in the right position within the cabinet as follows (see Figure 7–9):
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–15
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
WARNING
Cabinet rail edges may be sharp and can slice or abrade skin or cable insulation.
1. Turn the cabinet power off as described in Section 7.4.
2. Determine the correct enclosure mounting locations and corresponding cabinet rail mounting holes for the chassis rail assembly. Refer to the chapter in this document pertaining to your specific cabinet configuration for this information. The enclosure mounting hole specified for each position is the chassis rail locating hole shown in Figure 7–9.
7–16 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
WARNING
Use care in supporting the chassis rail assembly. It is heavy and awkward to position within the cabinet. If possible, use two persons to support and position the chassis rail assembly. The chassis rail assembly may cause personnel injury and equipment damage if dropped during installation.
Note
To ensure proper alignment of the chassis rail assembly, use care to position the round standoffs in the correct front and rear chassis rail locating holes.
3. From the front of the cabinet, position the chassis rail assembly at the correct mounting holes, as shown. Ensure that the rail bracket is positioned toward the front of the cabinet, and that the arrow on the rail bracket points up.
4. Insert the rear round standoff into the rear chassis rail locating hole.
5. Support the chassis rail against the rear vertical cabinet rail and maintain the rear round standoff in its locating hole. Extend the rail bracket to insert the front round standoff into its correct front chassis rail locating hole.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–17
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
Figure 7–9 Right Position Chassis Rail Installation
REAR VERTICAL
CABINET RAIL
REAR
CHASSIS
RAIL
LOCATING
HOLE
ROUND
STANDOFF
(2 PLACES)
INNER
FLANGE
U-NUT, 10-32
(4 PLACES)
INNER
FLANGE
FRONT VERTICAL
CABINET RAIL
OUTER
FLANGE
U-NUT, 10-32
(2 PLACES)
FRONT
CHASSIS
RAIL
LOCATING
HOLE
UP
SCREW, 10-32
SEMS
(4 PLACES)
CHASSIS
RAIL ASSEMBLY
RAIL
BRACKET
WASHER, LOCK
10-32, INTERNAL
(6 PLACES)
SCREW, 10-32
HEX CAP
(6 PLACES)
6. Using the shelf bracket as a template, mark the four U-nut mounting holes on the inner flanges of both the front and rear vertical cabinet rails. Make sure to use the correct set of holes in the chassis rail.
7. Temporarily remove the chassis rail assembly and install four U-nuts along the inner flanges of the front and rear vertical cabinet rails at the holes marked in step 6.
8. Reposition the chassis rail assembly as directed in steps 3 through 5.
CXO-3924A-MC
7–18 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
9. Fasten the chassis rail to the inner flanges of the front and rear vertical cabinet rails with 4 screws, as shown.
10. Fasten the rail bracket to the front vertical cabinet rail with its beveled nut bar and three screws, as shown.
11. Fasten the chassis rail to the rear vertical cabinet rail with its beveled nut bar and three screws, as shown.
12. Tighten the screws fastening the rail bracket to the chassis rail.
13. Install two U-nuts along the outer flange of the front vertical cabinet rail.
Install one U-nut at the hole just above the front chassis rail locating hole and the other at the eighth hole below the locating hole.
7.5.3 Left Position Chassis Rail Assembly Installation
Note
Install the chassis rail assembly in the left mounting position only if an enclosure is also installed in the right position. The bezel openings are designed to allow a single enclosure to be installed only in the right position.
Install the chassis rail assembly in the left position within the cabinet as follows (see Figure 7–10):
WARNING
Cabinet rail edges may be sharp and can slice or abrade skin or cable insulation.
1. Turn the cabinet power off as described in Section 7.4.
2. Determine the correct enclosure mounting locations and corresponding cabinet rail mounting holes for the chassis rail assembly. Refer to the chapter in this document pertaining to your specific cabinet configuration for this information. The enclosure mounting hole specified for each position is the chassis rail locating hole shown in Figure 7–10.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–19
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
WARNING
Use care in supporting the chassis rail assembly. It is heavy and awkward to position within the cabinet. If possible, use two persons to support and position the chassis rail assembly. The chassis rail assembly may cause personnel injury and equipment damage if dropped during installation.
Note
To ensure proper alignment of the chassis rail assembly, use care to position the round standoffs in the correct front and rear chassis rail locating holes.
3. From the rear of the cabinet, position the chassis rail assembly at the correct mounting holes, as shown. Ensure that the rail bracket is positioned toward the rear of the cabinet, and that the arrow on the rail bracket points up.
4. Insert the front round standoff into the front chassis rail locating hole.
5. Support the chassis rail assembly against the front vertical cabinet rail and maintain the front round standoff in its locating hole. Extend the rail bracket to insert the rear round standoff into its correct rear chassis rail locating hole.
6. Using the chassis rail as a template, mark the four U-nut mounting holes on the inner flanges of both the front and rear vertical cabinet rails. Make sure to use the correct set of holes in the chassis rail.
7. Temporarily remove the chassis rail assembly and install four U-nuts along the inner flanges of the front and rear vertical cabinet rails at the holes marked in step 6.
8. Reposition the chassis rail assembly as directed in steps 3 through 5.
9. Fasten the chassis rail assembly to the inner flanges of the front and rear vertical cabinet rails with 4 screws, as shown.
10. Fasten the rail bracket to the rear vertical cabinet rail with its beveled nut bar and three screws, as shown.
7–20 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.5 Chassis Rail Installation
Figure 7–10 Left Position Chassis Rail Assembly Installation
REAR VERTICAL
CABINET RAIL
OUTER
FLANGE
FRONT VERTICAL
CABINET RAIL
INNER
FLANGE
U-NUT, 10-32
(2 PLACES)
U-NUT, 10-32
(4 PLACES)
FRONT
CHASSIS
RAIL
LOCATING
HOLE
INNER
FLANGE
REAR
CHASSIS
RAIL
LOCATING
HOLE
ROUND
STANDOFF
(2 PLACES)
UP
RAIL
BRACKET
WASHER, LOCK
10-32, INTERNAL
(6 PLACES)
SCREW, 10-32
HEX CAP
(6 PLACES)
CHASSIS
RAIL ASSEMBLY
SCREW, 10-32
SEMS
(4 PLACES)
11. Fasten the chassis rail to the front vertical cabinet rail with its beveled nut bar and three screws, as shown.
12. Tighten the screws fastening the rail bracket to the chassis rail.
13. Install two U-nuts along the outer flange of the front vertical cabinet rail.
Install one U-nut at the hole just above the front chassis rail locating hole and the other at the eighth hole below the locating hole.
CXO-3923A-MC
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–21
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.6 Mounting the SF3x Storage Enclosure
7.6 Mounting the SF3x Storage Enclosure
Once the chassis rail is installed in the cabinet, the SF3x enclosure can be mounted on it. Mount the SF3x enclosure to the chassis rail as follows:
Note
The lock down brackets are mirror images of each other, and they are identified as the -01 and -02 versions. They must be installed with the orientation shown in the illustration.
1. Install the the two lock down brackets on the side of the SF3x enclosure near the front end, as shown in either Figure 7–11 or 7–12. Figure 7–11 shows the installation for the right mounting position, and Figure 7–12 shows the installation for the left mounting position.
WARNING
Use two persons to lift the SF3x enclosure. The unit is heavy and awkward to lift. Failure to use two persons to lift the enclosure may result in injury or damage to equipment.
2. From the front of the cabinet and using two persons, position the enclosure such that the machined grooves in the side of the enclosure mate with the upper and lower edges of the chassis rail.
CAUTION
Use care when sliding the enclosure into the cabinet. Do not allow the enclosure to pull or pinch cables that may be routed through the cabinet interior. Failure to use care when mounting the SF3x enclosure may result in equipment damage.
3. Slide the enclosure onto the chassis rail until the lockdown brackets contact the U-nuts on the front vertical cabinet rail.
4. Fasten the lock down brackets to the front vertical chassis rail with two hex cap screws, as shown in Figure 7–11 or 7–12.
7–22 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.6 Mounting the SF3x Storage Enclosure
Figure 7–11 Right Position SF3x Enclosure Mounting
SCREW, 10-32
HEX CAP
(4 PLACES)
WASHER, 10-32
LOCK
(2 PLACES)
WASHER, 10-32
FLAT
(2 PLACES)
LOCK DOWN
BRACKET
(-02)
FRONT VERTICAL
CHASSIS RAIL
U-NUT, 10-32
(2 PLACES)
(REF)
TAPE DRIVE
ENCLOSURE
(FRONT)
LOCK DOWN
BRACKET
(-01)
WASHER, 10-32
LOCK
(4 PLACES)
SCREW, 10-32
HEX CAP
(4 PLACES)
NOTE: TAPE DRIVE INTERNAL COMPONENTS NOT SHOWN FOR CLARITY.
CXO-3918A-MC
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–23
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.6 Mounting the SF3x Storage Enclosure
Figure 7–12 Left Position SF3x Enclosure Mounting
FRONT VERTICAL
CABINET RAIL LOCK DOWN
BRACKET
(-01)
WASHER, 10-32
FLAT
(2 PLACES)
WASHER, 10-32
LOCK
(2 PLACES)
SCREW, 10-32
HEX CAP
(2 PLACES)
U-NUT, 10-32
(2 PLACES)
(REF)
TAPE DRIVE
ENCLOSURE
(FRONT)
LOCK DOWN
BRACKET
(-02)
SCREW, 10-32
HEX CAP
(4 PLACES)
WASHER, 10-32
LOCK
(4 PLACES)
NOTE: TAPE DRIVE INTERNAL COMPONENTS NOT SHOWN FOR CLARITY.
CXO-3919A-MC
7–24 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.7 Installing the Power Cord
7.7 Installing the Power Cord
Install the power cord within the cabinet as follows:
CAUTION
Before performing the following steps, refer to the system documentation for the correct steps to perform an orderly shutdown of the system to which the DECarray cabinet is connected.
1. Install the ac power cord.
2. Connect the male end of the ac power cord to the the power controller as shown in Figure Figure 7–13. Refer to Table 7–3 if the DECarray cabinet is equipped with a single power controller. Refer to Table 7–4 if the
DECarray cabinet is equipped with dual power controllers.
Proper connection of ac power cords will ensure proper balancing of power distribution across all three phases of ac power. In both tables, device/position refers to cabinet positions 1 through 10.
Table 7–3 AC Power Distribution (Single Power Controller)
Phase
1
AC
Outlet ‡
J0
J1
J2
J3
Device/
Position
4
2
1
3
Label
A
A
A
A
2 J4
J5
J6
3 J7
J8
J9
‡ Power Controller AC outlet.
10
8
6
9
7
5
A
A
A
A
A
A
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–25
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.7 Installing the Power Cord
Table 7–4 AC Power Distribution (Dual Power Controllers)
Phase
AC
Outlet ‡ Device/Position Label
First Power Controller (Rear)
1 J0
J1
J2
J3
2 open open
4
A
A
A 2 J4
J5
J6
10 open open
3 J7
J8
J9
8 open
6
Second Power Controller (Front)
1 J0
J1
J2
J3
1 open open
3
2 J4
J5
J6
9 open open
3 J7
J8
J9
‡ Power Controller AC outlet.
7 open
5
B
B
B
B
A
A
B
7–26 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.7 Installing the Power Cord
Figure 7–13 Power Connection and Voltage Selection
D S S I
C O N N E C T O R S
1 0
P O W E R S U P P L Y
F A U L T I N D I C A T O R
( B E H I N D P A N E L )
A C R E C E P T A C L E A C P O W E R
S W I T C H
L I N E V O L T A G E
S E L E C T O R S W I T C H
( B E H I N D P A N E L )
S H R - X 0 1 2 7 A - 9 0
3. Check the factory set ac power on the SF7x enclosure. There are two model variants:
1. Model AA is 110 to 120 Vac
2. Model AB is 220 to 240 Vac
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–27
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.7 Installing the Power Cord
Note
Do not apply power at this time. Check to ensure that the factory set ac power is correct for your site. Call your Digital service representative if the factory set ac power is incorrect.
4. Refer to the SF3x Owner’s Manual for operation and setup of the SF3x enclosure.
7.8 Configuring the SF3x Enclosure
1. Perform the following steps if you are installing an SF3x enclosure in a position requiring that the enclosure be configured for split-bus mode
(single-system only):
CAUTION
To maintain stability, extend only one storage enclosure or magazine tape ISE on the slide mounts at a time.
a. Loosen the four captive slide assembly screws. Slide the inner assembly out until the drawer locks in the service position.
b. Push the inner assembly forward from the rear.
Note
Do NOT completely remove the inner drawer assembly from the extrusion tube and extend only one at a time.
c. Reconfigure the transition module (TTM) for split-bus mode by first moving the small black jumper to the split-bus terminals, then moving cable connectors to the right pair of sockets. Refer to Figure 7–14 and
Figure 7–15 to locate the TTM and jumper.
d. Push the SF7x inner drawer back in, replace the front cover door, and tighten the four front door screws.
7–28 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.8 Configuring the SF3x Enclosure
Figure 7–14 Changing an SF3x Enclosure to Split-Bus Mode
S P L I T - B U S M O D E
J 5 J 4 J 3 J 2
T H R U
S P L I T
J 1 1
T O O C P
S H R _ X 1 1 1 1 _ 8 9
To prevent pinching any cables, be sure that all cables are dressed correctly.
2. Position the OCP.
a. Adjust the SF3x OCP mount (Figure 7–15) to the
LEFT for positions 1,
3, 5, 7, and 9. Adjust the SF3x OCP mount to the
RIGHT for positions
2, 4, 6, 8 and 10.
b. Check that this and all other OCPs and magazine tape ISE fronts project through the front door of the DECarray cabinet correctly.
It may be necessary to adjust cabinet door mounting at the door hinges.
3. Check the DSSI ID switches on the OCP.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–29
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.8 Configuring the SF3x Enclosure
Figure 7–15 Adjusting the OCP
SLOTTED
HOLE
HOLE FOR
RIGHT
POSITION
HOLE FOR
LEFT
POSITION
TRANSITION
BOARD
SCREWS
SLOTTED
HOLE
TRANSITION
BOARD
(BEHIND FRAME)
S H R - X 0 1 2 4 - 9 0
4. Open the door on the front of the OCP. Ensure that the DSSI ID switches
(the three rightmost switches) are set according to Figure 7–16. If they are not, then use a pointed instrument to set the switches to their correct configuration. Refer to Table 7–5.
Note
The leftmost switch (MSCP) should in the down or enabled position at all times, unless you are instructed to change it to the up or disabled position.
7–30 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.8 Configuring the SF3x Enclosure
Figure 7–16 DSSI ID Switch Settings
d i g i t a l
Ready
Write
Protect
Fault
DSSI
ID
1
2
DSSI
ID
Ready
Write
Protect
Fault
S H R _ X 1 1 2 8 B _ 8 9
Table 7–5 SF3x Factory-Set DSSI Node IDs
Position
A
B
C
D
E
F
Backplane Location
upper left slot upper right slot middle left slot middle right slot lower left slot lower right slot
DSSI Node ID
0
1
2
3
4
5
You can change the DSSI node ID for an ISE in any given slot position by using DIP switches provided on the SF3x enclosure’s transition module.
Figure 7–17 shows the location of the switches for each slot position.
Table 7–6 shows what the switches must be set to for each slot position.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–31
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.8 Configuring the SF3x Enclosure
Table 7–6 DSSI Node ID Switch Settings for the SF3x Storage Enclosure
Slot Position Front Switch Rear Switch
DSSI Node
ID
Switch Positions
1
1 2 3 4
A S3 S10
6
7
4
5
2
3
0
1
X 1 0 0
X 0 0 0
X 1 1 0
X 0 1 0
X 1 0 1
X 0 0 1
X 1 1 1
X 0 1 1
B S1 S9
6
7
4
5
2
3
0
1
X 0 1 0
X 1 1 0
X 0 0 0
X 1 0 0
X 0 1 1
X 1 1 1
X 0 0 1
X 1 0 1
C
D
S6
S4
S7
S12
6
7
4
5
2
3
0
1
6
7
4
5
2
3
0
1
X 1 1 0
X 0 1 0
X 1 0 0
X 0 0 0
X 1 1 1
X 0 1 1
X 1 0 1
X 0 0 1
X 0 0 1
X 1 0 1
X 0 1 1
X 1 1 1
X 0 0 0
X 1 0 0
X 0 1 0
X 1 1 0
1
1 = On, 0 = Off, X = Does not matter.
(continued on next page)
7–32 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.8 Configuring the SF3x Enclosure
Table 7–6 (Cont.) DSSI Node ID Switch Settings for the SF3x Storage
Enclosure
Slot Position Front Switch Rear Switch
DSSI Node
ID
Switch Positions
1
1 2 3 4
E
F
S2
S5
S8
S11
6
7
4
5
2
3
0
1
6
7
4
5
2
3
0
1
X 1 0 1
X 0 0 1
X 1 1 1
X 0 1 1
X 1 0 0
X 0 0 0
X 1 1 0
X 0 1 0
X 0 1 1
X 1 1 1
X 0 0 1
X 1 0 1
X 0 1 0
X 1 1 0
X 0 0 0
X 1 0 0
1
1 = On, 0 = Off, X = Does not matter.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–33
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.8 Configuring the SF3x Enclosure
Figure 7–17 SF3x Transition Module DSSI Node ID Switches
S l o t C
R e a r
S l o t A
R e a r
S l o t F
R e a r
S l o t E
R e a r
S l o t D
R e a r
S l o t B
R e a r
S l o t D
F r o n t
S l o t B
F r o n t
S l o t E
F r o n t
S l o t F
F r o n t
S l o t A
F r o n t
S l o t C
F r o n t
M A - 0 4 3 8 - 9 2 . D G
CAUTION
Observe all ESD precautions and procedures. Antistatic wrist straps are provided inside the DECarray cabinet’s front and rear doors.
7–34 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.8 Configuring the SF3x Enclosure
5. Install the OCP (Figure 7–18).
Note
Make sure that the power is off to the enclosure.
Make sure that ALL the buttons are in the OUT position.
6. Make sure that all drive dc power switches are out.
7. At the rear of the SF3x enclosure, make sure that the ac power switch is
off or in the 0 position position (Figure 7–19).
8. Also check the select line voltage. Set it to the correct setting for your application.
9. At this time, connect the ac power cord to the SF3x enclosure.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–35
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.8 Configuring the SF3x Enclosure
Figure 7–18 SF3x Enclosure Front View Without Cover
Front
A B C D E F
Rear
A B C D E F
OPERATOR
CONTROL
PANEL
A B
C
D
E
Front
A B C D E F
F
Rear
A B C D E F
MA−0434−92.GRA
DC POWER
SWITCHES
7–36 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
Figure 7–19 SF3x Enclosure Rear View Without Cover
DSSI
Connectors
A
C
E
B
D
F
Power Supply
Fault Indicator
(Behind Panel)
FAULT
AC Receptacle AC Power
Switch
Line Voltage
Selected Switch
(Behind Panel)
MA−0430−92.GRA
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
This section describes the step-by-step procedure for cabling the SF3x storage enclosure to the existing DSSI bus configuration of the DECarray cabinet.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–37
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
Figure 7–20 shows the possible single-system configurations. Figure 7–21 shows the possible DSSI VAXcluster system configurations. Figure 7–22 shows the possible stripe set configurations.
Figure 7–20 Typical Single-System Bus Configurations
S Y S
A
3 0 0 - i n c h B C 2 1 Q - 2 5
M a g a z i n e
T a p e
I S E
T
4 2 - i n c h
B C 2 1 Q - 3 F
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
S Y S
A
3 0 0 - i n c h B C 2 1 Q - 2 5
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
C X O - 3 5 4 7 A - T I
Figure 7–21 Typical DSSI VAXcluster System Bus Configurations
S Y S
A
1 0 8 - i n c h
B C 2 1 Q - 0 9
S Y S
B
1 0 8 - i n c h
B C 2 1 Q - 0 9
S Y S
C
3 0 0 - i n c h B C 2 1 Q - 2 5
S F 3 x
S t o r a g e
E n c l o s u r e
D D
D D D
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
S Y S
A
1 0 8 - i n c h
B C 2 1 Q - 0 9
S Y S
B
3 0 0 - i n c h B C 2 1 Q - 2 5
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
D D D
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
C X O - 3 5 4 6 A - T I
7–38 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
Figure 7–22 Stripe Set Bus Configurations
S Y S
A
3 0 0 - i n c h B C 2 1 Q - 2 5
M a g a z i n e
T a p e
I S E
T
4 2 - i n c h
B C 2 1 Q - 3 F
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
D D D
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
S Y S
A
3 0 0 - i n c h B C 2 1 Q - 2 5
S F 3 x
S t o r a g e
E n c l o s u r e
D D D
D D D
D S S I T E R M I N A T O R
1 2 - 3 1 2 8 1 - 0 1
C X O - 3 5 4 5 A - T I
7.9.1 Through-Bus Configuration
Use the following procedures for cabling an SF3x storage enclosure in a
DECarray cabinet configured for single-system or DSSI VAXcluster system configurations in the through-bus mode.
The following procedures assume that all devices installed previous to a new installation of an SF3x storage enclosure are cabled in the single-system configuration.
7.9.1.1 Identifying DSSI Connectors on the System I/O Panel
The following procedure explains how to locate and identify the DSSI connections on the host system I/O panel:
Note
Before performing the following steps, refer to the system documentation for the correct procedure to perform an orderly shutdown of the systems in which the DECarray cabinet is connected.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–39
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
Note
This procedure assumes that no SF3x storage enclosures are installed internally in the system cabinet. If SF3x storage enclosures are in the system cabinet, then one of the KFMSA modules in the system XMI backplane must be connected to those SF3x storage enclosures. Do
NOT use this KFMSA module or its DSSI connections to connect the system to the DECarray. Do NOT count this KFMSA module in the following steps.
1. Open the system I/O panel on the system by removing the screws that secure the I/O panel to the system chassis. Let the panel swing down to its rest position.
2. Find the first KFMSA module installed in the XMI backplane of the system. It will be the KFMSA module in the lowest numbered slot of the
XMI backplane.
3. Follow the cabling from the backplane to the system I/O panel.
4. While viewing the front of the I/O panel, note that the DSSI connector on the left is KFMSA DSSI bus 2 and the DSSI connector on the right is
KFMSA DSSI bus 1. These connectors should be labeled BLUE for bus 1 and RED for bus 2.
5. Find the next KFMSA module installed in the XMI backplane of the system. It will be the next KFMSA module after the KFMSA module in the lowest numbered slot of the XMI backplane.
6. Follow the cabling from the backplane to the system I/O panel.
7. While viewing the front of the I/O panel, note that the DSSI connector on the left is KFMSA DSSI bus 2 and the DSSI connector on the right is
KFMSA DSSI bus 1.
If these connectors are not labeled, label them now with the small colored labels in the SF Family Label Booklet.
7.9.1.2 Cabling with a Magazine Tape ISE
WARNING
Before performing the following steps, refer to the system documentation for the correct procedure to perform an orderly shutdown of the system in which the DECarray cabinet is connected.
7–40 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
The following procedure is for cabling a storage enclosure with a magazine tape
ISE. Refer to Figure 7–23 for an illustration of the components.
1. Tighten the shipping screw in the rear, upper right corner, of the magazine tape ISE.
2. Remove the DSSI terminator from the bottom DSSI connector on the rear of the magazine tape ISE.
3. Install a 42-inch DSSI cable (BC21Q–3F) in the bottom DSSI connector on the rear of the magazine tape ISE.
4. Loosen the shipping screw in the rear, upper right corner, of the magazine tape ISE.
5. Pull the inner assembly of the magazine tape ISE out to the head cleaning position (first mechanical stop).
6. Route the DSSI cable to the nearest vertical rail and tie wrap.
7. Remove the two screws that hold the cable tray of the SF3x enclosure in place and slide the cable tray out to expose the four DSSI connectors.
8. Connect the 42-inch DSSI cable from the bottom DSSI connector of the magazine tape ISE to the rightmost DSSI connector for the rear ISEs in the SF3x storage enclosure.
9. If applicable, connect the 42-inch DSSI cable from the bottom DSSI connector of the magazine tape ISE to the rightmost DSSI connector for the front ISEs in the SF3x storage enclosure.
10. Install a DSSI terminator in the leftmost DSSI connector in the cable tray
(P2 for the rear ISEs and P4 for the front ISEs).
11. Slide the cable tray back into place and tighten the two screws.
12. Install an external DSSI cable from the top connector of the magazine tape
ISE to the appropriate KFMSA module.
CAUTION
Do not apply power to the SF3x storage enclosure at this time.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–41
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
Figure 7–23 Cabling an SF3x Enclosure in Through-Bus Mode
P 4
T e r m i n a t o r
P 3
P 2
T e r m i n a t o r
P 1
M A - 0 4 3 7 - 9 2 . D G
7.9.1.3 Cabling Positions 2, 3, 4, 7, and 8
CAUTION
Before performing the following steps, refer to the system documentation for the correct procedure to perform an orderly shutdown of the system in which the DECarray cabinet is connected.
7.9.2 Split-Bus Configuration
Perform the following procedure on each half of each SF3x enclosure that is being used in the split-bus configuration:
CAUTION
To maintain stability, extend only one storage enclosure or magazine tape ISE on the slide mounts at a time.
7–42 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
a. Remove the OCP from the front of the SF3x enclosure.
b. Remove the four slide assembly screws from the front of the enclosure and slide the inner assembly out until the drawer locks in the service position.
c. Push the inner assembly forward from the rear.
Note
Do NOT completely remove the inner chassis from the extrusion tube, and extend only one storage enclosure at a time.
d. Remove the fan assembly cover by loosening the four knurled screws that hold it to the chassis.
e. Carefully spread the cables and remove the fan assembly.
f. Remove the jumper cables from the from connectors J9 and J10 of the backplane (Figure 7–24).
g. Install DSSI terminators (12-28976-01) on J9 and J10.
h. Replace the fan assembly and cover.
i. Set the DSSI node ID switches for each ISE in that side of the enclosure
(see Table 7–6).
j. Push the inner chassis back in place and tighten the four front door screws.
Make sure that all cables are dressed correctly.
k. Remove the two screws that hold the cable tray in place and slide the cable tray out.
l. Attach cables to all four connectors on the cable tray (Figure 7–25).
Connectors P1 and P2 are for the rear ISEs. Connectors P3 and P4 are for the front ISEs.
m. Replace the cable tray.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–43
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
Figure 7–24 SF3x Backplane
P 1 0 P 9
7–44 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.9 Cabling the SF3x Enclosure in the DECarray Cabinet
Figure 7–25 Cabling an SF3x Enclosure in Split-Bus Mode
P 4
P 3
P 2
P 1
M A - 0 4 7 5 - 9 2 . D G
7.10 Powering Up the SF3x Enclosure
Follow these steps to apply power to a newly installed SF3x storage enclosure:
CAUTION
Ensure that the drive dc power switches on the front of the enclosure are in the out position.
1. Turn the ac power switch on the rear of the enclosure on (1). If the green power supply fault LED is lit, refer to the SF3x owner’s manual.
2. Press each of the drive dc power switches on the front of the SF3x enclosure, one at a time. If the green LED on the drive dc power switch does not light, refer to the SF3x owner’s manual.
3. Observe the OCP indicators for each drive. If the Ready indicator is lit and no other LED comes on and stays on, the drive has passed the power-on self-test (POST). If the Ready indicator does not come on and the red Fault indicator comes on, refer to the SF3x owner’s manual.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–45
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.10 Powering Up the SF3x Enclosure
4. Press each of the Ready buttons, one at a time. The Ready indicator should be on and stay on, with the Fault indicator remaining off. If a fault occurs, refer to the SF3x owner’s manual.
Once these steps are done and the drive has passed POST, then—and only then—should you proceed to the next section.
7.10.1 Updating the System Configuration Sheet
Once the enclosure has been successfully installed, power has been applied, and the drives have passed POST, you are ready to update the system configuration sheet to add the new ISEs.
Refer to the KFMSA Module Installation and User Manual for complete details on filling out a system configuration sheet.
7.11 Labeling the DSSI Cables
Use the following colored labels on the magazine tape ISE front panel and all
DSSI cables:
Label Color
Blue
Red
Yellow
Green
Blue & white
Red & white
Yellow & white
Green & white
Blue, red
Yellow, green
Blue, red & white
Yellow, green & white
I/O Port
1 Rear
1 Front
2 Rear
2 Front
3 Rear
3 Front
4 Rear
4 Front
7 Rear
7 Front
8 Rear
8 Front
7.11.1 Filling Out the Labels
Follow the instructions on the inside of the SF Family Label Booklet for filling out the labels for the DSSI cables and SF3x OCPs.
Proceed once you have filled out the cable and OCP labels.
7–46 Installing the SF3x Storage Enclosure in a DECarray Cabinet
Installing the SF3x Storage Enclosure in a DECarray Cabinet
7.11 Labeling the DSSI Cables
7.11.2 Labeling the Cables
For each cable installed, place a label 4 inches behind the connector as shown in Figure 7–26.
Figure 7–26 Placing a Label on a DSSI Cable
L A B E L
S H R - X 0 1 0 8 - 9 0
7.12 Final Verification
Once hardware installation, cabling and labeling, and the powering up steps are complete, you are ready to configure the DSSI subsystem and verify the correct operation of each ISE in the DECarray cabinet with the host system.
Refer to the KFMSA Module Installation and User Manual and the TF857
Magazine Tape ISE Service Manual for detailed information on the correct operation of each ISE. In these manuals, you will find the procedure for establishing the communications between the ISEs, the adapter module, and the system. You will also find the step-by-step procedures for reconfiguring the system with its newly installed DSSI devices.
Refer to the manuals for the disk ISE and tape ISE for detailed information on the local programs in the ISEs.
If at any time you detect a failure, refer to the SF3x owners manual.
Once the verification is complete, close the cabinet doors; turn the hex-Allen fasteners one half turn clockwise to lock. The system is ready to be turned over to the system manager.
Installing the SF3x Storage Enclosure in a DECarray Cabinet 7–47
8
Installation Troubleshooting
This chapter explains what to do if you detect problems with one or more
SF-series storage enclosure(s) during the installation of the DECarray cabinet.
The procedures in this chapter involve taking ISEs on and off line. This causes a failure in the communications with the ISEs affected, resulting in potential user problems. For this reason, the system manager should perform an orderly shutdown of all DSSI ISEs before any troubleshooting. Refer to the service or maintenance manuals for the affected ISEs.
8.1 Troubleshooting the Storage Enclosure
This section presents symptoms of a failed device, the probable cause or causes of the failure, and the corrective action to take for correcting the failure. Much of the corrective action calls either for taking a device or devices off line or for removing power from the enclosure containing the failed device.
WARNING
Take all ESD and safety precautions when handling the devices, especially when taking a device off line or when removing a device.
Failure to do so may damage the device.
Use the following basic steps for all troubleshooting that you perform for a disk
ISE in an SF-series storage enclosure, as it resides in a DECarray cabinet:
1. Inspect the ISE’s operator control panel (OCP). Is a Fault indicator lit? In the case of an SF7x storage enclosure, press the Fault button and read the error code.
2. Access the ISE in question. Gain access to the ISE’s various cables and check that they are seated correctly.
3. Run DRVTST or DRVEXR on the ISE by using DUP.
Installation Troubleshooting 8–1
Installation Troubleshooting
8.1 Troubleshooting the Storage Enclosure
4. According to the findings from the error codes and results from DUP, repair or replace the ISE.
5. Run EVCXE or EVCXF configuration programs.
6. Verify the repair or replacement of the ISE with DRVTST and DRVEXR under DUP.
7. Return the system to the user.
Use the information in Table 8–1 to isolate a failure in a storage enclosure.
Table 8–1 Troubleshooting Chart
Symptom(s)
No OCP indicators are lit.
Single Fault indicator lit on OCP.
Multiple Fault indicators lit on OCP.
Probable Cause(s)
1. Storage enclosure is not plugged in or not turned on.
2. Drive dc power switch is off.
3. OCP is not plugged in or seated firmly.
4. Bad OCP.
5. Bad transition module.
1. Faulty disk ISE.
2. Conflicting DSSI ID numbers.
1. Conflicting DSSI ID numbers.
2. Bad OCP.
3. Bad DSSI cable(s).
Corrective Action(s)
1. Plug in the ac power cord or turn on the ac Power.
2. Turn on the drive dc power switch.
3. Press the OCP firmly in place.
4. Configure and replace a new
OCP.
5. Configure and replace a new transition module.
1. Press lit Fault button. Read fault code.
1
Replace failed
FRU.
2. Verify correct DSSI node ID settings for that bus.
1. Verify correct DSSI node ID settings for that bus.
2. Configure and install a new
OCP.
3. Isolate with DSSI bus meter
2 and replace.
1
This step only applies to SF7x storage enclosures.
2
The DSSI bus meter, or DBM, is used to look at bus signals in real-time as well as to verify DSSI
ID numbers. The DBM can quickly locate faulty cables or duplicate DSSI ID numbers on a given
DSSI bus. The DSSI bus meter part number is 29–28008–01.
(continued on next page)
8–2 Installation Troubleshooting
Installation Troubleshooting
8.1 Troubleshooting the Storage Enclosure
Table 8–1 (Cont.) Troubleshooting Chart
Symptom(s) Probable Cause(s) Corrective Action(s)
One or more indicators continue to cycle.
One ISE is not accessible.
ISE is not seen or seen at unexpected DSSI ID value.
1. Conflicting DSSI ID numbers.
1. DC power to ISE is not on.
2. Bad ISE drive module.
1. Verify correct DSSI node ID settings for that bus.
1. Turn on dc power switch.
2. Replace ISE drive module.
3. Bad DSSI cable(s).
3. Isolate with DSSI bus meter
2 and replace.
4. Bad OCP cable.
4. Replace cable.
5. Bad power harness.
5. Replace power harness.
1. Check that both ends of
OCP cables are plugged in.
1. Cables are not plugged in the transition module or ISE.
2. Bad OCP ID switch.
3. Bad OCP cable.
1. Bad power supply.
2. Reconfigure and replace
OCP.
3. Replace appropriate OCP cable.
1. Replace power supply.
Fan is not spinning and power supply LED is lit.
2. Bad fan.
3. Bad transition module.
1. Bad power supply.
2. Replace fan.
3. Configure a new transition module and replace.
1. Replace power supply.
Fan is not spinning and power supply LED is not lit, but storage enclosure is on.
2. Bad power cord.
3. Bad transition module.
2. Replace cord.
3. Configure a new transition module and replace.
2
The DSSI bus meter, or DBM, is used to look at bus signals in real-time as well as to verify DSSI
ID numbers. The DBM can quickly locate faulty cables or duplicate DSSI ID numbers on a given
DSSI bus. The DSSI bus meter part number is 29–28008–01.
(continued on next page)
Installation Troubleshooting 8–3
Installation Troubleshooting
8.1 Troubleshooting the Storage Enclosure
Table 8–1 (Cont.) Troubleshooting Chart
Symptom(s)
In a DSSI VAXcluster installation, one or more of the following symptoms are observed:
-unexplained virtual circuit (VC) closures
-unexplained VMS crashes
-performance degradation
Probable Cause(s) Corrective Action(s)
1. Excessive ground offset voltage between DSSI
VAXcluster cabinets.
1. Refer to Chapter 2.
Measure ground offset voltage between cabinets.
Correct faults in power distribution system.
2. Loose or missing
DSSI terminators.
Install cabinet grounding wire between all cabinets sharing DSSI buses.
3. Low terminator power voltage.
3. Replace fuses.
4. Bus length too long.
4. Shorten bus.
5. Non Digital devices on bus.
6. Terminated midbus adapters
2. Tighten or replace DSSI terminators.
5. Replace with Digital devices.
6. Remove terminators from mid-bus adapters.
8.2 Removing an RF Disk ISE from an SF3x Storage
Enclosure
This section provides the procedure for removing an disk ISE from an SF3x storage enclosure.
WARNING
Take all possible ESD precautions when unpacking the disk ISEs.
Wear a correctly grounded ESD strap.
Have an orderly shutdown of the SF3x enclosure containing the disk
ISE performed. Refer to the system documentation.
1. Power down the SF3x enclosure.
a. Take the failed disk ISE on that DSSI bus off line by pressing and releasing each Ready button on the operator control panel (OCP). The button indicators go out.
8–4 Installation Troubleshooting
Installation Troubleshooting
8.2 Removing an RF Disk ISE from an SF3x Storage Enclosure
b. Press and release the drive dc power switches for all the ISEs on that
DSSI bus.
c. Remove the front cover Figure 8–1. Remove the two screws and lockers and lift off the cover.
2. Remove the disk ISE from the SF3x enclosure.
a. Remove the screw from the ISE carrier lever.
b. Pull the lever forward and slide the carrier out of the slot.
Installation Troubleshooting 8–5
Installation Troubleshooting
8.2 Removing an RF Disk ISE from an SF3x Storage Enclosure
Figure 8–1 Disk ISE Removal
LOCK
WASHER
PHILLIPS
SCREW
CXO-3952A-MC
3. Unpack the replacement RF disk ISE: a. Open the shipping carton.
b. Remove the disk ISE wrapped in the protective wrapper.
c. Open the protective wrapper and remove the disk ISE.
d. Place the disk ISE on the protective wrapper.
4. Remove the four screws holding the top cover on the carrier and remove the cover.
8–6 Installation Troubleshooting
Installation Troubleshooting
8.2 Removing an RF Disk ISE from an SF3x Storage Enclosure
5. Remove the faulty ISE from the carrier by removing the two screws on each side of the bottom of the carrier (see Figure 8–2).
6. Lift the ISE out of the carrier and disconnect the DSSI bus, OCP, and power connectors from the ISE.
7. Plug the DSSI bus, power, and OCP connectors into the replacement ISE.
8. Attach the ISE to the carrier.
9. Replace the top cover.
10. Install the disk ISE in the enclosure.
Proceed to Section 8.4.
Installation Troubleshooting 8–7
Installation Troubleshooting
8.2 Removing an RF Disk ISE from an SF3x Storage Enclosure
Figure 8–2 ISE Installation
P o w e r
C a b l e
D S S I
C a b l e
O C P
C a b l e
A
M A - 0 4 7 8 - 9 2 . D G
8–8 Installation Troubleshooting
Installation Troubleshooting
8.3 Removing an RF Disk ISE from an SF7x Storage Enclosure
8.3 Removing an RF Disk ISE from an SF7x Storage
Enclosure
This section provides the procedure for removing a disk ISE from an SF7x storage enclosure.
WARNING
Take all possible ESD precautions when unpacking the disk ISEs.
Wear a correctly grounded ESD strap.
Have an orderly shutdown of the SF7x enclosure containing the disk
ISE performed. Refer to the system documentation.
1. Power down the SF7x enclosure.
a. Take the failed disk ISE on that DSSI bus off line by pressing and releasing each Ready button on the operator control panel (OCP). The button indicators go out.
b. Press and release the drive dc power switch for the failed ISE.
2. Remove the disk ISE.
a. Remove the SF7x enclosure front cover (Figure 8–3). Loosen the screws and lift off the covers.
b. Loosen the wedges on the disk ISE.
Installation Troubleshooting 8–9
Installation Troubleshooting
8.3 Removing an RF Disk ISE from an SF7x Storage Enclosure
Figure 8–3 SF7x Front Cover Removal
O P E R A T O R C O N T R O L P A N E L ( O C P ) d i g i t a l
Ready
Write
Protect Fault
DSSI
ID
DSSI
ID
Ready
Write
Protect
Fault
F R O N T C O V E R
C A P T I V E S C R E W S
F R O N T C O V E R
D O O R
E N C L O S U R E
C A P T I V E S C R E W S
D R I V E D C P O W E R S W I T C H E S
S H R - X 0 1 2 6 A - 9 0
8–10 Installation Troubleshooting
Installation Troubleshooting
8.3 Removing an RF Disk ISE from an SF7x Storage Enclosure
c. Disconnect all cables to the disk ISE as shown in Figure 8–4.
Figure 8–4 Disconnecting the Cables
N O T E T O
I L L U S T R A T O R : f r o n t p a n e l f o r t h i s h a r d w a r e i s S H R _ X 1 1 2 7 _ 8 9
I S O L a n d r e d u c e d
1 7 / 6 4 ( . 2 6 5 6 2 5 )
Ready
Write
Protect
Fault
D S S I C A B L E t a l d i g i
Ready
Write
Protect
Fault
1 0 - P I N
O C P C A B L E
6 - P I N D R I V E
P O W E R C A B L E
S H R - X 0 1 3 5 A - 9 0 d. Remove the disk ISE as shown in Figure 8–5. Slide out the disk ISE gently, while holding all cables out of the way. Do not force the disk
ISE.
Installation Troubleshooting 8–11
Installation Troubleshooting
8.3 Removing an RF Disk ISE from an SF7x Storage Enclosure
Figure 8–5 RF Disk ISE Removal
N O T E T O
I L L U S T R A T O R : f r o n t p a n e l f o r t h i s h a r d w a r e i s S H R _ X 1 1 2 7 _ 8 9
I S O L a n d r e d u c e d
1 7 / 6 4 ( . 2 6 5 6 2 5 )
Ready
Write
Protect
Fault d i g i t a l
Write
Protect
Ready
Fault
S K I D P L A T E
R E T A I N I N G C L I P
S K I D P L A T E
S K I D P L A T E
T h i s w a s c r e a t e d b y r o t a t i n g S H R _ x 1 0 7 4 A _ 8 9 _ S C N
R W , Z 1 2 0
L O C A T I O N
S H R - X 0 1 3 5 - 9 0
S K I D P L A T E
G U I D E
T H I S R E P R E S E N T S
A R F 7 2
R F 7 X
S H R - X 0 1 2 8 - 9 0 - S C N
M A - 0 4 2 1 - 9 2 . D G
S H R - X 0 1 3 6 A - 9 0
3. Unpack the replacement RF disk ISE as follows: a. Open the shipping carton.
b. Remove the disk ISE wrapped in the protective wrapper.
c. Open the protective wrapper and remove the disk ISE. Discard the desiccant bags.
d. Place the disk ISE on the protective wrapper.
4. Remove the skid plate and wedges from the faulty disk ISE and install them on the replacement disk ISE (Figure 8–6).
8–12 Installation Troubleshooting
Installation Troubleshooting
8.3 Removing an RF Disk ISE from an SF7x Storage Enclosure
Figure 8–6 Disk Wedges and Skid Plate
R F 7 X
N O T E T O I L L U S T R A T O R :
T h i s i l l u s t r a t i o n i s a t . 3 0 % o f o r i g i n a l
W E D G E
S K I D P L A T E
M A - 0 4 2 2 - 9 2 . D G
S H R - X 0 1 5 8 A - 9 0
5. Position the RF disk ISE as shown in Figure 8–5 and install the disk ISE in the enclosure. Slide the disk ISE gently into place, while holding all cables out of the way. Do not force the disk ISE.
6. Verify that the disk ISE is locked into place and tighten the wedges.
7. Connect all cables as shown in Figure 8–7. Connectors are keyed so that the cables cannot be installed incorrectly.
Installation Troubleshooting 8–13
Installation Troubleshooting
8.3 Removing an RF Disk ISE from an SF7x Storage Enclosure
Figure 8–7 Cabling the RF Disk ISE
N O T E T O
I L L U S T R A T O R : f r o n t p a n e l f o r t h i s h a r d w a r e i s S H R _ X 1 1 2 7 _ 8 9
I S O L a n d r e d u c e d
1 7 / 6 4 ( . 2 6 5 6 2 5 )
Ready
Write
Protect
Fault
D S S I C A B L E d i g i t a l
Write
Protect
Fault
Ready
1 0 - P I N
O C P C A B L E
6 - P I N D R I V E
P O W E R C A B L E
S H R - X 0 1 3 5 A - 9 0
8. Replace the front cover on the SF7x enclosure (Figure 8–8).
Proceed to Section 8.4.
8–14 Installation Troubleshooting
Installation Troubleshooting
8.3 Removing an RF Disk ISE from an SF7x Storage Enclosure
Figure 8–8 SF7x Front Cover Replacement
O P E R A T O R C O N T R O L P A N E L ( O C P ) d i g i t a l
Ready
Write
Protect Fault
DSSI
ID
DSSI
ID
Ready
Write
Protect
Fault
F R O N T C O V E R
C A P T I V E S C R E W S
F R O N T C O V E R
D O O R
E N C L O S U R E
C A P T I V E S C R E W S
D R I V E D C P O W E R S W I T C H E S
S H R - X 0 1 2 6 A - 9 0
Installation Troubleshooting 8–15
Installation Troubleshooting
8.4 Bringing the RF Disk ISE On Line
8.4 Bringing the RF Disk ISE On Line
This section provides the procedure for bringing the ISEs in the storage enclosure on line.
1. Ensure that the DSSI node ID switches are set correctly, if applicable.
2. Place the ac power switch at the rear of the storage enclosure to the 1 (on) position.
3. Press all drive dc power switches.
4. Press all Ready buttons on the OCP, one at a time.
5. If no Fault indicators are lit, then continue. If a Fault indicator is lit, recycle the dc power once. If the failure appears again, refer to the appropriate previous section.
6. Run the EVCXE or EVCXF programs to add the new disk ISE to the configuration and to change any disk ISE internal parameters, if necessary.
7. Update the system configuration sheet.
8. Run DRVTST and DRVEXR (under DUP) to verify the correct operation of the new disk ISEs.
9. Return the system to the user.
8.5 Troubleshooting the Magazine Tape ISE
Refer to the magazine tape ISE documentation for troubleshooting information.
8–16 Installation Troubleshooting
A
DECarray Configuration Sheets
This appendix contains blank configuration sheets.
Figures A–1, A–2, and A–3 are to be used with systems containing variants of the KFMSA adapter module. Figures A–4 and A–5 are to be used with systems containing either KFQSA adapter modules or embedded DSSI adapter(s).
DECarray Configuration Sheets A–1
DECarray Configuration Sheets
Figure A–1 Single-System Configuration Sheet (Dual Port)
KFMSA/Single−System Configuration Sheet
[for VAX 6000 and 9000 systems]
Bus
DSSI ID #
KFMSA XMI Node #
Bus
DSSI ID #
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
Color Code
Color Code config_shr−x0109.rags
A–2 DECarray Configuration Sheets
DECarray Configuration Sheets
Figure A–2 Two-Host DSSI VAXcluster Configuration Sheet (Dual Port)
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
K F M S A / D S S I V A X c l u s t e r C o n f i g u r a t i o n S h e e t
B u s
D S S I I D #
B u s
D S S I I D #
K F M S A X M I N o d e #
K F M S A X M I N o d e #
B u s
D S S I I D #
B u s
D S S I I D #
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
M A - 0 4 2 7 - 9 2 . D G
DECarray Configuration Sheets A–3
DECarray Configuration Sheets
Figure A–3 Three-Host DSSI VAXcluster Configuration Sheet (Dual Port)
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
B u s
D S S I I D #
B u s
D S S I I D #
K F M S A X M I N o d e #
B u s
D S S I I D #
B u s
D S S I I D #
K F M S A X M I N o d e #
K F M S A X M I N o d e #
B u s
D S S I I D #
B u s
D S S I I D #
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
D e v i c e T y p e
D S S I I D #
N o d e N a m e
S y s t e m I D
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
A L L O _ C L A S S
D E C a r r a y #
U N I T N U M
M A - 0 4 2 8 - 9 2 . D G
A–4 DECarray Configuration Sheets
DECarray Configuration Sheets
Figure A–4 Single-System Configuration Sheet (Single Port)
[for MicroVAX II, MicroVAX/VAXserver 3xxx (Q−bus), and VAX 4000 systems]
Device Type
DSSI ID #
Device Type
DSSI ID #
Device Type
DSSI ID #
Array Pos. #
Array Pos. #
UNITNUM
Array Pos. #
UNITNUM
Array Pos. #
UNITNUM
Array Pos. #
UNITNUM
Array Pos. #
UNITNUM
Color Code
DECarray Configuration Sheets A–5
DECarray Configuration Sheets
Figure A–5 DSSI VAXcluster Configuration Sheet (Single Port)
DSSI VAXcluster Configuration Sheet
[for MicroVAX II, MicroVAX/VAXserver 3xxx (Q−bus), and VAX 4000 systems]
DSSI ADAPTER
Bus
DSSI ID #
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
Device Type
DSSI ID #
Node Name
System ID
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
ALLO_CLASS
Array Pos. #
UNITNUM
DSSI ADAPTER
Bus
DSSI ID #
Color Code config_double,rags
A–6 DECarray Configuration Sheets
A
Assembly of chassis rail, 6–9
B
Bringing on line disk ISE, 8–16
C
Chassis rails, SF3x enclosure installing SF3x enclosure chassis rails,
7–13
Chassis rails, SF7x enclosure installing SF7x enclosure chassis rails,
6–9
Chassis rails, tape drive installing tape drive chassis rails, 5–10 completing, 6–34
Configuration sheets, DECarray, A–1
Converting to split-bus mode, 6–24, 7–29,
7–42
D
DECarray configuration sheets, A–1 description, 1–1 doors, how to open, 3–10 final verification of single-system configuration, 4–13 inspection, 3–10 installation of, 4–1 magazine tape ISE, 5–1
Index
DECarray installation of (cont’d)
SF3x storage enclosure in, 7–1
SF7x storage enclosure, 6–1 leveling, 3–5, 3–9 overview, 1–1 placement of, 3–8 powering up single-system configuration, 4–11 preparing a site for, 2–1 recommended environmental limits, 1–5 unloading procedures, 3–5 unpacking, 3–1
DSSI bus meter, 8–2, 8–3
DSSI ID switch settings
SF3x, 7–31
SF7x, 6–26
E
Exterior panels reinstalling, 5–24
I
Inspection, 5–3, 6–3 of DECarray, 3–10 of ramps, 3–5 of shipped equipment, 3–1, 7–2
Installation of DECarray, 2–1, 4–1 of magazine tape ISE, 5–1 of SF3x storage enclosure, 7–1 of SF7x, 6–1
Index–1
Installation (cont’d) troubleshooting, 8–1
Installation of left position chassis rail assembly, 6–14 right position chassis rail assembly, 6–11
Installing
TF8x7-series tape drives, 5–5
L
Labeling cables magazine tape ISE installation, 5–31
SF3x installation, 7–46
SF7x storage enclosure installation, 6–37
Labeling the magazine tape ISE, 5–31
Labeling the SF7x storage enclosure, 6–37
Labels, filling out magazine tape ISE installation, 5–31
SF3x installation, 7–46
SF7x storage enclosure installation, 6–37 single-system configuration, 4–8
Labels, placement of on DSSI cables, 5–31, 6–37, 7–47 on magazine tape ISE, 5–31 on SF7x storage enclosure, 6–37 single-system configuration, 4–8
Loading sequences configuration rules, 4–17, 5–5, 6–5
M
Magazine tape ISE final verification, 5–33 installation in a DECarray, 5–2 kit contents, 5–3 labeling cables, 5–31 labels, filling out, 5–31 powering up, 5–27 troubleshooting, 8–16 unpacking, 5–2 where to install, 5–4
Magazine tape subsystem cabling, 5–25
P
Power-up
DECarray single-system configuration, 4–11 magazine tape ISE, 5–27
SF3x storage enclosure, 7–45
SF7x storage enclosure, 6–33
R
Ramp inspection, 3–5
RF disk ISE bringing on line, 8–16 removal from SF3x storage enclosure,
8–4 removal from SF7x storage enclosure,
8–9
S
Safety precautions disconnecting power source, 4–1 unloading storage array, 3–4
SF3x storage enclosure cabling for Single-system configuration, 7–39 in DECarray, 7–37 final verification, 7–47 installation procedure, 7–9 kit contents, 7–2 labeling cables, 7–46 labels, filling out, 7–46 powering up, 7–45 removing the RF disk ISE, 8–4 unpacking, 7–2 where to install, 7–3
SF7x storage enclosure cabling, 6–31 configuring, 6–23 final verification, 6–37 installation procedure, 6–5 installing in a DECarray cabinet, 6–2 kit contents, 6–3
Index–2
SF7x storage enclosure (cont’d) labeling cables, 6–37 labels, filling out, 6–37 mounting, 6–17 power cord installing, 6–20 powering up, 6–33 reinstalling exterior panels, 6–30 removing the RF disk ISE, 8–9 unpacking, 6–2 where to install, 6–4
Side panels reinstalling, 5–24 removal, 5–8, 6–7, 7–11 removing, 5–8, 6–7, 7–11
Single-system configuration cabling for SF3x, 7–39
Site preparation for DECarray, 2–1
Split-bus mode, 7–3 converting to, 6–24, 7–29, 7–42
Storage enclosure overview, 1–6 to 1–8
Stripe set configurations, 7–39
System configuration sheet, 5–28 checking for SF3x installation, 7–5 completing for single-system configuration,
4–8 updating, 5–28, 6–33 updating for SF3x installation, 7–46
T
TERM PWR indicator, 4–11
TF8x7-series tape drives installation of, 5–5
Thermal stabilization, 3–2
Tools, required for magazine tape ISE installation, 5–1 for SF3x installation, 7–1 for SF7x storage enclosure installation,
6–1 for troubleshooting
DSSI bus meter, 8–2
Troubleshooting basic steps, 8–1 installation, 8–1 magazine tape ISE, 8–16 storage enclosure, 8–1
Troubleshooting chart, 8–2
U
Unloading procedures, DECarray, 3–5
Unpacking
DECarray, 3–1 magazine tape ISE, 5–2
SF3x storage enclosure, 7–2
SF7x storage enclosure, 6–2
V
Verification, final of magazine tape ISE, 5–33 of SF3x storage enclosure, 7–47 of SF7x storage enclosure, 6–37 of single-system configuration, 4–13
Index–3
Download
Advertisement
Key features
Installs SF-series storage enclosures and magazine tape ISEs
Supports DSSI interface capability
Provides optional dual ac power capability
Has five levels, each with two storage enclosure positions
Allows access to storage devices control panels through front door
SF3x holds up to 12 half-height, 3 1/2-inch ISEs
SF7x holds up to 4 full-height, 5 1/4-inch ISEs
Offers through-bus or split-bus configuration option
Each disk ISE has independent control via enclosure's OCP
Provides DC power for all disk ISEs within the enclosure
Frequently asked questions
The DECarray cabinet must be operated within specific temperature, humidity, and altitude ranges. Ensure adequate space is provided around the cabinet for airflow, access to doors, and cable routing. Install the DECarray cabinet in a Class A computing environment, and ensure the floor can support the weight of the cabinet. Refer to the manual for detailed specifications.
The guide provides instructions for both single-system and DSSI VAXcluster configurations. It includes steps for cabling, labeling, and verifying the configuration. Refer to the manual for specific procedures and diagrams.
The manual lists required tools and equipment, including wrenches (7/16-inch, 9/16-inch, 3/4-inch), safety glasses, and other necessary hardware. Ensure that all tools are in good working condition before starting the installation.