MODEL AK-450-12 AK-450-24 AK-450-36


Add to my manuals
4 Pages

advertisement

MODEL AK-450-12 AK-450-24 AK-450-36 | Manualzz

450W Single Output Power Supply

Features:

Universal AC input / Full range

Built in active PFC function, PF > 0.90

+5V / 0.3A auxiliary output

150% Peak load Capability

Constant current limit

Power OK signal

Remote ON / OFF, Remote sense function

Protection: OVP, OLP, OTP, SCP, Fan failure

3 years warranty

AK-450

series

Output

Input

MODEL

DC Voltage Range

Rated Current

Current Range

Rated Power

Ripple & Noise (Max.)

Voltage Adj. Range

Voltage Tolerance

Line Regulation

Load Regulation

Setup, Rise Time

Hold Up Time (Typ.)

Voltage Range

Frequency Range

Power Factor (Typ.)

Efficiency (Typ.)

AC Current (Typ.)

Inrush Current (Typ.)

Leakage Current

Over Load

AK-450-12 AK-450-24 AK-450-30 AK-450-36 AK-450-48

Note.2

Note.3

12V

37.5A

0 ~ 37.5A

450W

24V

19A

0 ~ 19.0A

456W

30V

15A

0 ~ 15.0A

450W

<1% (mVp-p), according to the rated Output Voltage

±10% Typical adjustment by potentiometer

±1.0%

±0.5%

±0.5%

36V

12.7A

0 ~ 12.7A

457W

48V

9.5A

0 ~ 9.5A

456W

Note.4

800ms, 60ms at full load

16ms / 230VAC at full load

90 ~ 264VAC, 127 ~ 370VDC

47 ~ 63Hz

0.98 / 230VAC, 0.99 / 115VAC at full load

89% 91% 91% 92%

4.5A / 115VAC, 2.2A / 230VAC

27A / 115VAC, 54A / 230VAC

< 1.0mA / 240VAC

Hiccup mode: when the rated output power is within 105 ~ 150% for more than 3secs.

Constant current limit: > 150% rated power / short circuit

93%

Auto-recovery: If O/P drop to 40% of the rated output voltage, PSU will shut down and auto-recover

5times (If fault condition remains after 5times recovery, PSU will shut down. User must re-power on to recover)

Protection

Over Voltage

Over Temperature

14.4 ~ 15.6V

28.8 ~ 31.2V

36.0 ~ 39.0V

43.2 ~ 46.8V

Protection type: Latch-style (Recovery after reset AC power ON or inhibit)

57.8 ~ 62.4V

By detecting primary and secondary heat sink.

Protection type: Shut down o/p voltage (Auto recovers automatically after temperature goes down)

Function

Environment

Auxiliary Power

Remote ON / OFF Control

Power OK Signal

Working Temp.

Working Humidity

Storage Temp. & Humidity

Temp. Coefficient

Vibration

External switch or NPN Transistor to turn ON / OFF

Open drain signal low when PSU turns on, Max. sink current: 20mA, Max. drain voltage: 40V.

-20 ~ +70°C (Refer to output load de-rating curve)

20 ~ 90% RH non-condensing

-40 ~ +85°C, 10 ~ 95% RH

±0.02% / °C (0 ~ 50°C)

10 ~ 500Hz, 5G 10min. / 1cycle, period for 60min. each along X, Y, Z axes Compliance to

IEC 68-2-6, IEC 68-2-64

Safety & EMC

Others

Note

Note.5

Safety Standards

Withstand Voltage

Isolation Resistance

EMI Conduction & Radiation

Harmonic Current

Note.6

EMS Immunity

MTBF

Cooling

Dimension (WxHxD)

Packing

Certified UL 60950-1; EN 60950-1

I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC), 1min

I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC

Certified EN 55022

Certified EN 61000-3-2; EN 61000-3-3

Certified EN 55024; IEC 61000-4-2, 3, 4, 5, 6, 8, 11

74.71K HRS Certified MIL-HDBK-217F

105x41x199 mm / 4.134x1.614x7.835 inch

1.1kg; 18pcs / 20.1kg / 1.02CUFT

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.

3. Tolerance: includes set up tolerance, line regulation and load regulation.

4. De-rating may apply in low input voltage. Please check the de-rating curve for more details.

5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still

meets EMC directives.

6. Conduct this test without enclosure.

REV. B3

13/03/13

1

Mechanical Specification:

450W Single Output Power Supply AK-450

series

Unit:mm[inch]

Airf low direction

4-M4 L=5mm

AC Input & DC Output

Pin No. Assignment

Pin No.

1

2

3

4,5

6,7

Assignment

AC/L

AC/N

FG

-V

+V

Control pin number assignment (CN2): JST S8B-PHDSS or equivalent

Pin No.

1

2

3

4

Assignment

AUX

GND

P-OK

EN-

Pin No.

5

7

8

Assignment

GND

EN+

VS+

VS-

Mating Housing

PHDR-08VS

Terminal

SPHD-002T-P05

Function Description of CN2:

Pin No.

7

8

5

6

3

4

1

2

Function

AUX

GND

P.OK

EN-

GND

EN+

VS+

VS-

Description

+5V / 0.3A auxiliary power

Ground

Power OK

Remote ON/OFF (–)

Ground

Remote ON/OFF (+)

Remote voltage sense (+)

Remote voltage sense (–)

8-M4 L=5mm

REV. B3

13/03/13

2

450W Single Output Power Supply AK-450

series

De-rating Curve:

Load V.S Temp.

100

80

60

40

20

-20 0 10 20 30 40 50

Ambient Temperature (°C)

60 70

Load V.S I/P Voltage

100

90

80

70

60

50

40

90

100 110 120

Input Voltage (Vac)

Ta=25°C

264

Peak Loading:

I-peak

I

I-normal

0

T-normal

T-peak

T

T-

PEAK

represents the period during which the output current is at 110% to 150% of nominal (shown as I-

PEAK

). Curve B shows the relationship between the percentage of peak current (I-

PEAK

) and the allowable duration (T-

PEAK

).

If the peak current is taken for longer that the allowed duration indicated by curve B, the output current will drop to a constant limited current of 105% of nominal, then.

The unit between peak currents (T-

NORMAL

) is dependant up on the output current drawn between the peaks (I-

NORMAL

) and curve A shows the relationship between the two.

The higher the percentage of normal current (I-

NORMAL

) is of the nominal current, the longer the interval (T-

NORMAL

) before the next peak current can be drawn.

T-normal (sec.)

24

20

16

12

8

4

0

10 20 30 40 50 60 70 80 90 % I-normal

T-peak (sec.)

24

20

16

12

8

4

0

110 115 120 125 130 135 140 145 150 % I-peak

CURVE A CURVE B

REV. B3

13/03/13

3

1. Power OK Signal and Auxiliary output

450W Single Output Power Supply AK-450

series

DC / DC

5V / 0.3A

* Place an additional capacitor to have a better

performance of auxiliary power operation.

* The grounding of "AUX" power should be

connected to "GND" port. If " V-" is connected

as Grounding, make sure to short the GND

and V- ports.

* 470μF

10V

AUX.

LOAD

2. Remote ON/OFF Control

(A)

2KΩ

AUX

EN+

SW

5V

EN-

GND sw

OFF

ON

Power ON

Power OFF

(A) Using internal 5V auxiliary source

(B)

AUX

2K Ω

EN+

5V

ENTr

GND

L / H

GND

Tr

L

H

Power ON

Power OFF

(B) ON / OFF Control by NPN transistor

5V

2K Ω

AUX

EN+

EN-

5V

SW

GND sw

OFF

ON

Power ON

Power OFF

(C) Using external voltage source

3. Remote Sense

2

GND

CN2

AUX

1

ENP-OK

EN+

VS-

GND

VS+

8 7

+V -V

R Load

REV. B3

13/03/13

4