TransTel Lodging Manual
Oglas
Oglas
SK-200 - Lodging
SYSTEM INSTALLATION &
PROGRAMMING MANUAL
Notification
Notification is hereby given that TransTel Communications Inc. reserves the right to modify, change, update or revise this document from time to time as required without the prior obligation to notify any person, company or organization. Further, TransTel makes no warranty or representation, either express or implied, with respect to merchantability, or fitness for a particular purpose.
© 1998 TransTel Communications Incorporated
This document or any parts thereof are not be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems for any purpose whatsoever without the express written permission of TransTel Communications Inc.
IMPORTANT NOTICE: PLEASE READ!
This equipment is capable of providing users access to interstate providers of operator service through the use of access codes. Modification of this equipment by call aggregators to block access dialing codes is a violation of the Telephone
Operator Consumers Act of 1990.
November 1998, Issue 1.0
TransTel Communications, Inc.
SK-200 Lodging Manual
Equal Access Compliance Notification
SK-200 Lodging Package
Installation & Programming Manual
Table of Contents
Installation Safety Precautions
................................................................................................. 1
Introduction To Installation
.................................................................................................... 4
FCC and Telephone Company Rules and Regulations
......................................... 4
FCC Registration Number
........................................................................................... 4
Ringer Equivalence Number
....................................................................................... 4
Protection devices
................................................................................................................... 7
Site Requirements
.................................................................................................................... 7
Location
.......................................................................................................................... 7
Power Supply
................................................................................................................. 7
Equipment Requirements
....................................................................................................... 7
Check Equipment
.......................................................................................................... 7
Installation check list
................................................................................................... 8
Cabinet Installation
.................................................................................................................. 9
Expansion
....................................................................................................................... 9
Cabinet Switch Identifier Settings
............................................................................. 9
Cabinet Assembly
....................................................................................................... 10
Inter-Cabinet Cabling
................................................................................................. 10
Wall mounting
.............................................................................................................. 11
System Grounding
...................................................................................................... 11
Printed Circuit Board (PCB) Installation
............................................................................ 12
Main components
....................................................................................................... 12
Printed Circuit Board Insertion
................................................................................ 13
Power Supply Installation
......................................................................................... 13
Select the input voltage
................................................................................................. 13
SK-CPU/2 Installation
................................................................................................. 14
SK-IPC/2 Installation
.................................................................................................. 16
SK-TRK/2 Installation
................................................................................................. 17
Meter Pulses Detector Card
.......................................................................................... 18
SK-STI Installation
...................................................................................................... 19
SK-200 Lodging Package Installation & Programming Page i
External Backup Battery Connection
......................................................................20
Installing or Replacing Batteries
..................................................................................20
Charging the Battery
.......................................................................................................21
Trunk and Station Cabling
....................................................................................................22
Trunk Cabling
...............................................................................................................22
Station Lines Cabling
.................................................................................................22
Key Telephone Wiring
................................................................................................22
Single Line Telephone Wiring
...................................................................................24
DSS Console Wiring
....................................................................................................24
Off Hook Call Announce ( OHCA )
...........................................................................27
Optional Cabling
.....................................................................................................................28
Doorphone Connection
..............................................................................................28
Door Switch Connection
............................................................................................28
Station Message Detail Recording (SMDR)
............................................................29
Background Music and Music on Hold Connection
.............................................30
External Paging Equipment Connection
.................................................................31
External Input Sensor
.................................................................................................31
Power On and Operational Test
...........................................................................................32
Operational Tests
........................................................................................................32
Programming Initialization
....................................................................................................33
Entering Program Mode
.........................................................................................................33
Password
.......................................................................................................................33
To Enter System Programming Mode From Any Station
....................................33
To Enter Programming Mode From The First Key Phone Port In the System.
.............................................................................................................................33
Programming Overlay and Default Soft Key Plans
..........................................................34
Programming Overlay
.................................................................................................34
Default Soft Key plan for Group 3.
...........................................................................34
Hidden Features for DSS keys
..................................................................................35
On Line Programming
............................................................................................................35
Remote Programming using a modem and the system manager.
................................35
System Manager
..........................................................................................................36
Remote Programming System to System
..........................................................................37
Function Keys -- for system programming
........................................................................38
LCD display - For System Programming
............................................................................39
Station Numbering Plan
.........................................................................................................40
System Default
.............................................................................................................40
Change Station Numbering Plan
..............................................................................40
If the original numbering plan is two-digit
.................................................................40
If the original numbering plan is three-digit
..............................................................40
If the original numbering plan is four-digit:
...............................................................40
Available station numbers
.........................................................................................40
Programming Applicable to Station Numbering
...................................................40
Programming Description
.....................................................................................................41
Program 01-tk-IP:Ringing Assignment - Day Service
..........................................41
Page ii
Program 02-tk-IP :Ringing Assignment - - Night Service
.................................. 41
Program 03-nn-IP : Door Ring Assignment
......................................................... 42
Program 04-gp-IP : Console Assignment
............................................................ 42
Program 05-01-IP : System Timing Parameters - 01
........................................... 43
Item 01 - Hold Recall Time
............................................................................................ 43
Item 02 - Exclusive Hold Recall Time
......................................................................... 43
Item 03 - Hold Recall Timeout
...................................................................................... 43
Item 04 - DISA Access Delay Time
.............................................................................. 44
Item 05 - Busy Remind Cycle Time (Off-Hook Ringing)
.......................................... 44
Item 06 - Pause Time
...................................................................................................... 44
Item 07 - DTMF Generation Time
................................................................................. 44
Item 08 - Call Forward No Answer Transfer Time
.................................................... 44
Program 05-02-IP : System Timing Parameters - 02
.......................................... 45
Item 01 - SLT Dial Tone Timeout
................................................................................. 45
Item 02 - SLT Inter-Digit Timeout
................................................................................ 45
Item 03 - Auto Redial Ringing Time:
........................................................................... 45
Item 04 - SLT Release Signal
....................................................................................... 45
Item 05 - CO Line Flash Time - Key Phone & SLT
.................................................. 47
Item 06 - SLT Hold (Flash) Signal
............................................................................... 47
Item 07 - Ring On Time
.................................................................................................. 47
Item 08 - Ring Off Time
.................................................................................................. 47
Program 05-03-IP : System Timing Parameters - 03
.......................................... 48
Item 01 - Make/Break Ratio
........................................................................................... 48
Item 02 - Automatic Trunk Search
............................................................................... 48
Item 03 - Intercom Call Signaling Method
.................................................................. 48
Item 04 - PABX (Centrex) Outgoing Code
.................................................................. 48
Item 05 - Toll Access Code
........................................................................................... 49
Item 06 - Station Numbering Plan
............................................................................... 49
Item 07 - Intercom Dial Tone Pattern
.......................................................................... 49
Item 08 - Door Phone Ring Pattern
............................................................................. 49
Program 05-04-IP : System Timing Parameters - 04
.......................................... 50
Item 01 - Baud rate For RS232 Port
............................................................................ 50
Item 02 - Dial 9 Flag
........................................................................................................ 50
Item 03 - Action for Call Duration Limiting
................................................................ 50
Item 04 - 12/24 Hour Clock
............................................................................................ 51
Item 05 - Flash Delay Time:
.......................................................................................... 51
Item 06 - Speed Dialing Distribution
........................................................................... 51
Item 07 - Single Digit Intercom
..................................................................................... 51
Item 08 - Message Waiting Method for Single Line Phones
.................................. 51
Program 05-05-IP : System Timing Parameters - 05
.......................................... 54
Item 01 - Morning Call
.................................................................................................... 54
Item 02 - Metering Detector
.......................................................................................... 54
Item 03, 04 - Speed Dial Unrestricted 1, 2
.................................................................. 55
Item 05 - Name Function
............................................................................................... 55
Item 06 - Dial Tone Detection
....................................................................................... 55
SK-200 Lodging Package Installation & Programming Page iii
Item 07 - Auto Redial Times
..........................................................................................55
Item 08 - Auto Redial Pause Time
................................................................................55
Program 05-06-IP : System Timing Parameters - 06
...........................................57
Item 01 - Transfer Busy Recall Timeout
.....................................................................57
Item 02 - Transfer Idle Recall Timeout
........................................................................57
Item 03 - DISA and ACD-1 VSU Grouping
...................................................................57
Item 04 - Polarity Reversal
.............................................................................................58
Item 05 - Operator Code
.................................................................................................58
Item 06 - Unsupervised Conference and ECF Time Setting
...................................58
Item 07 - Hold Feature for SLT
......................................................................................58
Item 08 - Not Used
...........................................................................................................58
Program 05-07-IP : System Timing Parameters - 07
...........................................59
Item 01 - Intercom Searching
........................................................................................59
Item 02 - Toll Override Prevention from quick dial
...................................................59
Item 03 - Reserved
...........................................................................................................59
Item 04 - DISA Recall To Console - No Digits Dialed
...............................................59
Item 05 - Toll Restriction Override Prevention
..........................................................61
Item 06 - SMDR Digit Mask
............................................................................................61
Item 07 - Meter Pulse Detect Delay Time
....................................................................61
Item 08 - Reserved
...........................................................................................................61
Program 05-08-IP : System Timing Parameters - 08
...........................................63
Item 01 - Hunt Time Setting
...........................................................................................63
Item 02 - DSS Access To Other Trunk group
.............................................................63
Item 03 - SLT Camp On Tone
........................................................................................63
Item 04 - DISA Transfer Group
......................................................................................64
Item 05 - SLT Programming Digit
.................................................................................64
Item 06 - DISA /DID Transfer Time No Answer
..........................................................64
Item 07 - DISA Transfer Time No Dialing
....................................................................64
Item 08 - Hunt Group Ring Method
..............................................................................64
Program 05-09-IP : System Timing Parameters - 09
...........................................66
Item 01 - External Paging Control
................................................................................66
Item 02 - Console Queuing
............................................................................................67
Item 03 - Clear Forward Signal Detection - Loop Disconnect
................................67
Item 04 - DISA Busy Tone Detection
...........................................................................67
Item 05 - Save Redial Numbers - 1 or 6
.......................................................................67
Item 06 - ACD-1 Enable Time
........................................................................................67
Item 07 - ACD-1 Segment 2 Recall Time
.....................................................................68
Item 08 - ACD-1 Release Time
......................................................................................68
Program 05-10-IP : System Timing Parameters - 10
...........................................69
Program 05-11-IP : System Timing Parameters - 11
...........................................71
Item 01 - Resume KeyPhone Volume Settings On Plug In
......................................71
Item 02 - Number of DISA Passwords
.........................................................................71
Item 03 - Select Music on Hold or Ring Back Tone
..................................................71
Item 04 - DISA Call Processing Method When The VSU is busy or not Installed
.............................................................................................................................................72
Page iv
Item 05 - DISA Special Function Access
.................................................................... 72
Item 06 - DISA Re-check Times To Station/Console
............................................... 72
Item 07 - Door Phone Ringing Time
............................................................................ 72
Item 08 - DISA Single Digit Dialing
.............................................................................. 72
Program 05-12-IP : System Timing Parameters - 12
........................................... 74
Item 01 - Reserved
.......................................................................................................... 74
Item 02 - Reserved
.......................................................................................................... 74
Item 03 - Exclusive Hold Capability
............................................................................ 74
Item 04 - Door Unlock Relay Activation Time
........................................................... 74
Item 05 - Voice Mail Call Forward Protocol Selection and Muting Leading Digits
............................................................................................................................................ 75
Item 06 - Linear/Circular Trunk Group Access
......................................................... 76
Item 07 - LED indication of Check in/ Check out
...................................................... 76
Item 08 - Fire Alarm Ringing Time
............................................................................... 76
Program 05-13-IP : System Timing Parameters - 13
........................................... 77
Item 01 - PMS (Fidelio) Enable
.................................................................................... 77
Item 02 - Reserved
.......................................................................................................... 77
Item 03 - Call Cut Off Timer - No Polarity Reversal Received
............................... 77
Item 04 - Door phone Ring Frequency for Key Phones
.......................................... 77
Program 05-14-IP : System Timing Parameters - 14
........................................... 78
All Items currently Reserved and Unused
................................................................. 78
Program 06-IP : Relay Assignment
....................................................................... 79
Program 07-gp-IP : Flexible Key Group Assignment
........................................ 80
Default Key Telephone Templates
.............................................................................. 80
Key Telephone Function Codes
.................................................................................. 81
Program 08-01-IP : Flexible DSS Key-Group Assignment
............................... 83
Program 09-nnn-DP : System Speed Dial
............................................................ 84
Program 10-gp-IP: Intercom or DISA Single Digit Assignment
...................... 85
Program 11-IP : Date and Time Setting
................................................................ 86
Program 12-nn : System Alarm Clock
.................................................................. 87
Program 13-nn : Password
..................................................................................... 88
Program 14-01-IP: SMDR Specifications
.............................................................. 89
Item 01 - Call duration start time
................................................................................. 89
Item 02 - Record Incoming Calls
................................................................................. 89
Item 03 - Record Local Calls
........................................................................................ 89
Item 04 - Record Incoming Calls No Answer
............................................................ 89
Item 05 - Print the Header
............................................................................................. 90
Item 06 - Number of records between the Header
................................................... 90
Item 07 - SMDR Output Port (SK-200)
......................................................................... 90
Item 08 - Polarity Reversal and Mini Accounting Feature
...................................... 90
Program 17-nn : Forced Account Code
............................................................... 93
Program 18-nn-TK : Assign Toll Plans To Trunk Lines
..................................... 94
Program 19-IP : Voice Service (VPC) Assignment
.............................................. 95
Remote VSU Recording Feature
.................................................................................. 96
Program 20-nn : Define Day-Time Schedule
....................................................... 98
SK-200 Lodging Package Installation & Programming Page v
Program 25 : Reset Data to System Default
........................................................99
Program 26-gp-IP : DID Route Table (Analog Indial)
.........................................100
Program 27-tk-IP : Print Programming Data
.......................................................100
Program 29-tk-IP : Trunk Specifications - 2
........................................................101
Item 01 - Place Calls On Hold Awaiting Answer
......................................................101
Item 02 - ACD-1 Function Enable
...............................................................................102
Item 03 - ISDN Incoming Call Type
............................................................................102
Item 04 - Set Ring Frequency (SK 1/sets Only)
.......................................................102
Item 05 - Allow Audible Ring For Incoming Calls
...................................................103
Item 06 - Trunk Timer Start Time:
..............................................................................103
Program 30-gp-IP
......................................................................................................104
Program 33-gp-IP
.........................................................................................................104
Program 34-gp-IP
......................................................................................................104
Program 35-tk-IP : Trunk Specifications - 1
........................................................105
Item 01 - Trunk Type
.....................................................................................................105
Item 02 - Trunk Signal
...................................................................................................105
Item 03 - External Call Forward - ECF
.......................................................................106
Item 04 - DISA/ECF (Direct Inward System Access/External Call Forward)
......106
Item 05 - Pick Up
............................................................................................................106
Item 06 - Loud Bell
........................................................................................................107
Item 07 - Inward Line Ringing Method Assignment (Day)
.....................................107
Item 08 - Inward Line Ringing Method Assignment (Night)
..................................109
Program 36-gp-tk : Trunk Group Assignments
..................................................110
Program 37-tk : Busy Out Trunks
.........................................................................111
Program 38-gp-tk : Dial 87 Trunk Group Assignment
......................................111
Program 39-IP : Sensor Assignment
...................................................................112
Program 40-st-IP : Station Class of Service - 1
.................................................114
Item 01 - Override Level
...............................................................................................114
Item 02 - Monitor Level:
................................................................................................114
Item 03 - Limit call duration:
......................................................................................114
Item 04 - Station Loud Bell
..........................................................................................115
Item 05 - Access Paging
...............................................................................................115
Item 06 - Be Paged
........................................................................................................115
Item 07 - Security code status
....................................................................................115
Item 08 - Forced account code
...................................................................................115
Program 41-st-IP : Station Specifications
...........................................................116
Item 01 - Station group
.................................................................................................116
Item 02 - Flexible key pattern group assignments (key phone)
...........................116
Item 03 - Shift Key Group For KeyPhone
..................................................................116
Item 04 - Dial 9 trunk group
.........................................................................................117
Item 05 - Toll plan - Day
...............................................................................................117
Item 06 - Toll plan - Night
.............................................................................................117
Item 07 - Port number
...................................................................................................117
Program 42-st-IP : Register Memory Block for Individual Speed Dial
...........118
Program 43-cn-IP : Port Specifications
..............................................................120
Page vi
Item 01 - Station number
............................................................................................. 120
Item 03 - Key pattern group assignments for DSS
................................................ 121
Item 04 - Disallow SLT Connection
........................................................................... 121
Program 44-st-IP : Station Class of Service - 2
................................................. 122
Item 01 - System Alarm
................................................................................................ 122
Item 02 - Hold feature
................................................................................................... 122
Item 03 - Call Split
......................................................................................................... 122
Item 04 - Manual Line
................................................................................................... 123
Item 05 - Headset feature
............................................................................................ 123
Item 06 - Use Engineering Password
........................................................................ 123
Item 07 - DTMF Receiver Control For Voice mail Ports
........................................ 123
Item 08 - Station Alarm Signal
.................................................................................... 123
Program 45-st-IP : Station Class of Service - 3
................................................. 124
Item 01 - Intercom Call Limitation
............................................................................. 124
Item 02 - Dual port Capability
..................................................................................... 124
Item 03 - Ringing Volume Up Gradually Capability
............................................... 124
Item 04 - Allow Trunk Access
..................................................................................... 125
Item 05 - Intercom Calls to Different Station Groups
............................................ 125
Item 06 - Receive Break Alarm
................................................................................... 125
Item 07 - Allow Unrestricted Speed Dial Access
.................................................... 125
Item 08 - Record Station's SMDR Data
..................................................................... 125
Program 46-st-IP : Station Class of Service - 4
................................................. 126
Item 01 - Dial [87] Trunk Group
.................................................................................. 126
Item 02 - Message Waiting Level
............................................................................... 126
Item 03 - Automatic Answer Capability
.................................................................... 126
Item 04 - DISA/DID/Indial Recall Capability
............................................................. 128
Item 05 - Maximum Re-Transfer Times
.................................................................... 128
Item 06 - Door Unlock/DND/CFWD Access
.............................................................. 128
Item 07 - Telephone Software Type
.......................................................................... 128
Program 47-st : Hot line Assignment
.................................................................. 129
Program 48-st-IP : Register Memory Blocks for Function Keys
.................... 130
Program 49-st-IP : Register Credit Limit (SK-200)
............................................ 130
Program 50-st-IP : Station Class of Service - 5
................................................. 131
Item 01 - Disable SPK/HOLD/TRF Key
...................................................................... 131
Item 02 - Call Forward LED Indicator
........................................................................ 131
Item 03 - ISDN Incoming Call Display Type)
............................................................ 131
Program (51 to 56)-code-IP : Toll Plans - Allowed Digits - Class 1 to 6
....... 132
Program (61 to 66)-code-IP : Toll Plans - Restricted Digits - Class 1 to 6
... 134
Program (57 & 58)-code-IP : Toll Plans - Allowed Digits - Class 7 & 8
......... 135
Program 59-code-IP : Toll Plan - Common Permitted Code - Class 9
.......... 135
Program 67-Gp-IP : Hunt Group Pilot Number
.................................................. 136
Program 68-Gp-IP : Hunt Group Assignment - Day
.......................................... 137
Program 69-Gp-IP : Hunt Group Assignment - Night
....................................... 137
Appendix A - Name Function Programming
................................................................... 138
Appendix B - Programming Cross reference
................................................................. 139
SK-200 Lodging Package Installation & Programming Page vii
Ringing Assignment
.................................................................................................139
DISA
..............................................................................................................................139
DISA Transfer
.................................................................................................................139
Voice Service (Optional)
..............................................................................................139
Night Transfer
............................................................................................................139
Trunk Pick up
.............................................................................................................140
Trunk Specifications
.................................................................................................140
Intercom Call Signaling
............................................................................................140
Hunt Groups
...............................................................................................................140
Dial Tone Pattern
.......................................................................................................140
Single Digit Dialing
....................................................................................................140
Direct Station Select
.................................................................................................140
Operator Calls
............................................................................................................140
Intercom Dialing Restriction
...................................................................................141
Dial 9/87 Settings
.......................................................................................................141
Outgoing Code
...........................................................................................................141
Trunk Specifications
.................................................................................................141
Speed Dial
...................................................................................................................141
Auto-Redial
.................................................................................................................141
Hold & Hold Recall
....................................................................................................142
Busy Remind signal (Off Hook Signaling)
............................................................142
Message Waiting Level
.............................................................................................142
Override
.......................................................................................................................142
Console Assignment
.................................................................................................142
Flexible Key Group Assignment
.............................................................................142
Trunk Group
...............................................................................................................142
Group Assignment (Station Specifications)
........................................................142
Toll Restriction
...........................................................................................................143
Code Assignment
..........................................................................................................143
Forced Account Code
...............................................................................................143
Call Limit
.....................................................................................................................143
Passwords
..................................................................................................................143
Station Lock
................................................................................................................143
Busy Out Trunk
..........................................................................................................143
Time Setting
................................................................................................................143
System Alarm
.............................................................................................................143
Morning Call
................................................................................................................144
Flexible Station Numbering
.....................................................................................144
SLT Parameters
.........................................................................................................144
Paging
..........................................................................................................................144
Call Split
......................................................................................................................144
Call Transfer
...............................................................................................................144
Call Forward No Answer Transfer Time
................................................................145
Hot Line
.......................................................................................................................145
Doorphone & Doorswitch
........................................................................................145
Page viii
DSS Console
.............................................................................................................. 145
Fax Monitor
................................................................................................................ 145
Headset
....................................................................................................................... 145
Loud Bell (Trunk)
...................................................................................................... 145
Loud Bell (Station)
.................................................................................................... 145
External Music Source
............................................................................................. 145
Paging (External Paging)
........................................................................................ 146
SMDR
........................................................................................................................... 146
Meter Pulse Detection
.............................................................................................. 146
Voice Processing Service
....................................................................................... 146
System Reset
............................................................................................................. 146
SK-200 Lodging Package Installation & Programming Page ix
Page x
SK-200 Lodging Package Installation & Programming Page xi
Page xii
IMPORTANT SAFETY INSTRUCTIONS
Installation Safety Precautions:
1. Never install telephone wiring during a lightning storm.
2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
3. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
4. Use caution when installing or modifying telephone lines.
SAVE THESE INSTRUCTIONS
The SUPERKEY
®
SK-200 utilizes a detachable power supply cord. This cord is not to be attached to any building surfaces.
IMPORTANT SAFETY INSTRUCTIONS
instructions.
When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
1. Read understand and all cord. Do not locate this product where the cord will be abused by persons walking on it.
2. Follow all warnings and instructions marked on the product.
3. Unplug this product from the wall outlet
10. Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock. before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
4. Do not use this product near water, for example, near a bath tub, wash bowl, kitchen sink, or laundry tub, in a wet
11. Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product. basement, or near a swimming pool.
5. Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product.
6. Slots and openings in the cabinet and the back or bottom are provided for ventilation, to protect it from overheating, these openings must not be blocked or covered.
The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or
12. To reduce the risk of electric shock, do not
13. disassemble this product, but take it to a qualified service person when some service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks.
Incorrect reassembly can cause electric shock when the appliance is subsequently used.
Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions: heat register. This product should not be placed in a built-in installation unless proper ventilation is provided.
7. This product should be operated only from the type of power source indicated on the marking label. If you are not sure of the type of power supply to your home or office, consult your dealer or local power company.
8. This product is equipped with a three wire grounding type plug. The plug will only fit into a grounding type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet.
Do not defeat the safety purpose of the grounding type plug.
9. Do not allow anything to rest on the power
F. If the product exhibits a distinct change in
A. When the power supply cord or plug is damaged or frayed.
B. If liquid has been spilled into the product.
C. If the product has been exposed to rain or water.
D. If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions. Improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation.
E. If the product has been dropped or the cabinet has been damaged. performance.
Page 2
14. Avoid using a telephone (other than a cordless type) during an electrical storm.
There may be a remote risk of electric shock from lightning.
15. Do not use the telephone to report a gas leak in the vicinity of the leak.
SAVE THESE INSTRUCTIONS
SK-200 Lodging Package Installation & Programming Page 3
Introduction To Installation
The Superkey
®
Series Model SK-200 is an advanced electronic hybrid telephone system employing a microprocessor stored program and digitally controlled solid-state space division switching. With 10 available card slots in a single cabinet, the system provides capacity for up to 20 Central Office (outside) lines and up to 72 system stations. Total expansion capacity allows the system to be expanded up to four cabinets, with a total maximum capacity of 40 card slots, which can be equipped in any capacity not to exceed 40 Central Office lines and 240 system stations. Each incremental cabinet provides ten additional card slots for system expansion. The software structure was developed to accommodate multilanguage support in order to adapt efficiently to world markets.
Users who are familiar with other Superkey
®
products will find the operation of the SK-200 to be almost identical to other
SK series telephone systems. Installation and maintenance personnel will find the database structure of the SK-200 to be very similar to other SK series systems.
This manual is intended to provide the information required for the physical installation of the SK-200. It is recommended that the installer refer to the separate feature and programming document for fully detailed information on these items.
FCC and Telephone Company Rules and Regulations
In compliance with the requirements of Part 68 of the Federal Communications Commission Rules and Regulations for connection of terminal system equipment to the telephone network and for your convenience, the following information is presented:
FCC Registration Number
The Superkey
®
SK-200 is registered with the FCC in a dual registration capacity enabling the system to operate as a key system only or as a hybrid system.
Superkey SK-200 FCC Registration Number: 3A7TAI-21978-KF-E and 3A7TAI-21765-MF-E.
Ringer Equivalence Number
Ringer Equivalence Number of CO Line Circuit:
USOC code required for Central Office lines: RJ-11-C
Page 4
1. Notification of the Telephone Company
Customers connecting terminal equipment to the telephone network shall, upon request of the
Telephone Company, inform the Telephone Company of the particular line(s) to which such connection is made, the FCC registration number and ringer equivalence number (REN) of the registered terminal equipment.
The REN is useful to determine the quantity of devices you may connect to your telephone line and still have all of those devices ring when your telephone number is called. In most, but not all areas, the sum of the REN's of all devices connected to one line should not exceed five (5.0). To be certain of the number of devices you may connect to your line, as determined by the REN, you should contact your local telephone company to determine the maximum REN for your calling area.
2. Direct Connection to a Party-Line or Coin Operated Telephone Line is Prohibited.
3. Incidence of Harm to the Telephone Lines
Should terminal equipment cause harm to the Telephone Network, the Telephone Company shall, where practical, notify the customer that service may be temporarily discontinued. However, where prior notice is not practical, the Telephone Company may temporarily discontinue service, if such action is reasonable in the circumstances. In case of such un-notified temporary discontinuance of service, the Telephone Company shall:
(a) Promptly notify the customer of such temporary discontinuance of service.
(b) Afford the customer the opportunity to correct the situation which gave rise to the temporary discontinuance.
(c) Inform the customer of the right to bring a complaint to the FCC pursuant to the procedures set out in Subpart E of Part 68 of FCC Telephone Equipment Rules.
SK-200 Lodging Package Installation & Programming Page 5
4. Compatibility of the Telephone Network and Terminal Equipment.
(a) Availability of telephone interface information.
Technical information concerning interface parameters and specifications not specified in FCC Rules, including the number of Ringers which may be connected to a particular line, which is needed to permit Terminal Equipment to operate in a manner compatible with Telephone Company communications facilities, shall be provided by the
Telephone Company upon customer's request.
(b) Changes in Telephone Company Communications Facilities, Equipment, Operations and Procedures.
The Telephone Company may make changes in its communications facilities, equipment, operations or procedures where such action is reasonably required in the operation of its business and is not inconsistent with the rules and regulations in FCC
Part 68 of the FCC Rules and Regulations. If such changes can be reasonably expected to render any customer Terminal Equipment incompatible with Telephone
Company Communications Facilities, or require modification or alteration of such
Terminal Equipment, or otherwise materially affect its use or performance, the customer shall be given adequate notice in writing to allow the customer an opportunity to maintain uninterrupted service.
5. Radio Frequency Interference
This equipment generates and uses radio frequency energy and if not installed and used properly and in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type-tested and found to comply with the limits for a Class B computing device in accordance with the specification in Subpart J of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation.
However, this is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient the receiving antenna.
Relocate the equipment with respect to the receiver.
Move the equipment away from the receiver.
Plug the equipment into a different outlet so that equipment and receiver are on different branch circuits.
Page 6
Protection devices
Be sure the primary protection device at the entry point is installed by the local telephone company (telco) in accordance with the National Electrical Code (NEC). If no such device is provided, notify the telephone company BEFORE proceeding with the installation.
Site Requirements
Location
The System should be installed in a clean, dry, secure location. This place must have adequate ventilation, and a temperature from 32
°
F to 113
°
F (0
°
C to 45
°
C) , with 10% to 95% non-condensing relative humidity.
DO NOT install the equipment near sources of static electricity, excessive vibration, or water.
Avoid direct sunlight.
Power Supply
Be sure that the third wire ground of the AC circuit is connected with earth ground. If a music source/external paging equipment is installed, it must be connected to a separate AC circuit rather than the system's dedicated AC line cord. (The power supply
must be connected to a dedicated AC outlet.)
CAUTION: For continued protection against risk of fire, replace only with the same type and rating of fuse. Fuses are listed below:
Equipment Requirements
Operating Voltage
120V AC 50/60 Hz
220V AC 50/60 Hz
Fuse Rating
5 Amp 250 VAC
3.5 Amp 250 VAC
Check Equipment
Check the cartons of equipment: Key Service Unit, Telephone sets, Component units, or other options for visible damage. If any damage is evident, contact the supplier.
Use plywood as a backboard to wall mount the cabinet.
Three-pair twisted station cable should be used to provide for OHCA.
Grounding wire (14 AWG).
Appropriate installation tools.
SK-200 Lodging Package Installation & Programming Page 7
Installation check list
INSTALLATION REQUIREMENTS
MOUNTING SURFACE
AC LINE
POWER OUTLET
SURGE PROTECTION
VENTILATION AND TEMPERATURE
GROUNDING REQUIREMENTS
SERVICEABILITY
VERIFICATION
Verify that the surface is flat, dry and has an electrical outlet within a reasonable distance.
AC line should be dedicated exclusively to the system.
Power Outlet must be a 3-wire grounded outlet plug, having parallel blades and ground pin.
Input power Line capacity requirements - 10 amperes.
A Surge Protector is recommended on the dedicated AC line.
Humidity: 10% to 95% relative non-condensing
Temperature:32
°
F to 113
°
F
(0
°
C to 45
°
C).
A Cold Water Pipe or other approved ground connection.
Lighting conditions and working space are adequate for future service.
Page 8
Cabinet Installation
Expansion
Recommended Cabinet Position
Cabinet Switch Identifier Settings (SW4 on the SK-CCB/2)
2: 2nd Cabinet
1: 1st Cabinet
3: 3rd Cabinet
4: 4th Cabinet
SK-200 Lodging Package Installation & Programming Page 9
Cabinet Assembly
Inter-Cabinet Cabling
Page 10
Wall mounting
Install the screws into the plywood with appropriate fasteners using the template for a guide for the screws.
Hook the Unit on the screws.
System
Grounding
It is strongly recommended that the system be grounded by connecting a heavy, insulated copper wire (e.g., 14AWG or larger) between the grounding bolt on the front inside of the cabinet and an earth ground.
Do not connect the grounding wire of the unit to a computer, telex, or any other external device.
SK-200 Lodging Package Installation & Programming Page 11
Printed Circuit Board (PCB) Installation
Main components of the system are:
Power Supply Unit (SK-PWR/2).
Cabinet (SK-200).
Central Processing Unit (SK-CPU/2).
Interface Processing Controller (SK-IPC/2).
DTMF Generation Card (SK-DTMF/2).
Trunk & Station Unit (SK-TRK/2, SK-STI/802, SK-STI/082 ).
RS-232 Interface Card (SK-RS232)*.
Remote Programming Interface Card (SK-RPI)*.
Expand Memory Card (SK-EMC/2)*.
Voice Service Card (SK-VSU/2)*.
*:optional
Note: Only the 1st Cabinet needs to have the SK-CPU/2 installed .
Page 12
Installation Information
CAUTION!!
The Printed Circuit Boards of SK-200 are sensitive to static electricity.
During installation and maintenance, take precautions against static damage.
Printed Circuit Board Insertion
Raise the Extractor of the Printed Circuit Board, with components facing right.
Hook the extractor onto the metal edge of the case, press down the extractor, and push the Printed Circuit Board into the slot until it is fully inserted.
Power Supply Installation
The Power Supply for the unit can be configured for:
110-VAC: 100 to 120 V AC (50/60Hz) or
220-VAC: 210 to 230 V AC (50/60Hz).
Select the input voltage by the 110/220 jumper on the SK-PWR/2
It is important to verify that the setting is correct prior to initial system power up.
Verify that the input voltage and input voltage jumper are correct before you power up the system.
Installation steps:
Check the Jumper for the input voltage on the SK-PWR/2 to assure that it is correct for your power source.
Insert the SK-PWR/2 into left-most card slot of the Main Cabinet.
Secure the power supply unit by the screws.
SK-200 Lodging Package Installation & Programming Page 13
Note:
VR1: +28V Voltage Adjuster (Factory use only).
VR2: +28V Current Limit Adjuster (12A, Factory use only).
VR3: +12V Voltage Adjuster (Factory use only).
VR4: +5V Voltage Adjuster (Factory use only).
Fuse 1: 250V/3A for protecting 5V/12V output.
Fuse 2: 250V/8A for protecting battery connection.
SK-CPU/2 Installation
Attach the optional cards - SK-RS232, SK-RPI, SK-EMC/2 on the SK-CPU/2.
To select the music sources for MOH (Music on Hold) and BGM (Background Music).
MOH: Use External Music 2 MOH: Use Melody IC
BGM: Use External Music 1
Same Music Source for MOH and BGM:
Independent Music Sources for MOH and BGM:
BGM: Use Melody IC
Music disable: Music on:
Page 14
Note:
SW1: Reset button.
VR1: Volume Control for Melody IC.
Remove the insulating paper from BAT1.
1) SK-CPU/2 has a LITHIUM Battery (3V/170 mAh) for system data's back up. The system data is maintained for about 2266 hours (94 days = 3 months) during power failure.
2) A plastic isolation paper is on the Lithium battery to isolate power during transportation. Please take off this paper after the system is ready for use.
Adjust SW2, SW3, SW4, SW5 according to the number of SK-TRK/2 cards that you wish to install.
Table 1 Link Path Setting
Qty. of
SK-TRK/2
1~2
3
4
5
6
7
8
9
10
SW2 - DIP
1~4 5~8 on on off on off off off off off off off off off off off off off off
SW3 - DIP
1~4 on on on off off off off off off
5~8 on on on on off off off off off
SW4 - DIP
1~4 5~8 on on on on on on on on on on off on off off off off off off
SW5 - DIP
1~4 on on on on on on on off off
5~8 on on on on on on on on off
Insert the SK-CPU/2 into the position according to Figure 6 PCB Location.
SK-200 Lodging Package Installation & Programming Page 15
SK-IPC/2 Installation
Attach the optional cards - SK-RS232, SK-DTMF/2 on the SK-IPC/2.
Insert the SK-IPC/2 into the position according to figure 6 PCB Location.
Page 16
SK-TRK/2 Installation
Insert the SK-TRK/2 into the position according to Figure 6, Printed Circuit Board Locations.
SK-200 Lodging Package Installation & Programming Page 17
To select the system link paths for the installed SK-TRK/2 card. (On: Short, Off: Open.)
Table 2 Assign Link Paths for SK-TRK/2
SKJ1 J2
TRK/2
1~4 1~4
Position
1st on off
2nd off on
3rd off off
4th off off
5th off off
6th off off
7th off off
8th off off
9th off off
10th off off
J3
1~4 off off on off off off off off off off
J4
1~4 off off off on off off off off off off
J5
1~4 off off off off on off off off off off
J6
1~4 off off off off off on off off off off
J7
1~4 off off off off off off on off off off
J8
1~4 off off off off off off off on off off
Meter Pulses Detector Card (Not applicable to most U.S. Applications)
*** Refer to Figure 10 SK-TRK/2
1) SK-PMxx is an optional daughter board installed for each trunk line.
2) There are two kinds of detectors:
SK-PM12: Metering Detector Card for 12 KHz
SK-PM16: Metering Detector Card for 16 Khz
3) Remove the MDJC1(A,B,C,D)/MDCJ2(A,B,C,D) jumpers of the SK-TRK/2 before installing
Meter Pulse Detector boards. (The jumpers must remain on the SK-TRK/2 if you don't install the Meter
Pulse Detector board.)
4) To install these Meter Pulse Detector boards, simply plug them onto the SK-TRK/2.
J10
1~4 off off off off off off off off off on
J9
1~4 off off off off off off off off on off
Page 18
SK-STI Installation
Insert the SK-STI card into the position according to Figure 6, Printed Circuit Board Locations.
SK-200 Lodging Package Installation & Programming Page 19
Cabling:
External Backup Battery Connection:
The Service Unit can have two external backup batteries in series (12 volts each) for emergency power supply when a power failure takes place. Be sure to connect the battery line by referring to the following direction:
Installing or Replacing Batteries
Caution
- To Reduce the Risk of Fire or Injury to persons, Read and Follow these
Instructions.
1. Use only the following type and size batteries:
12 Volt 6.5 Amp/Hour "Gel-Cell" sealed batteries (2).
Dimensions, approximately 3 1/4" (H), 5 15/16" (W), 2 1/2" (D).
PowerSonic model PS660 or equivalent.
2. Do not dispose of the batteries in a fire. The cell may explode. Check with local codes for possible special disposal instructions.
3. Do not open or mutilate the batteries. Released electrolyte is corrosive and may cause damage to the eyes or skin. It may be toxic if swallowed.
4. Exercise care in handling batteries in order not to short the battery with conducting materials such as rings, bracelets, and keys. The battery or conductor may overheat and cause burns.
Page 20
This product is defined as a secondary battery operated device. As such, the following instructions should also be read and followed:
1. Charge the batteries provided with or identified for use with this product only in accordance with the instructions and limitations specified in this manual.
2. Observe proper polarity orientation between the batteries and battery charger.
3. Do not mix old and new batteries in this product.
4. Do not mix batteries of different sizes or from different manufacturers in this product.
Before installing or replacing batteries, turn off the battery supply switch to the KSU and
disconnect the polarized battery connector at the KSU. Due to the weight of the
batteries, it is advised that the battery cabinet be removed from the wall before working
on it.
Charging the Battery:
The rechargeable batteries are automatically charged when the Battery Supply Switch is on.
Change the batteries every two years.
You can determine the capacity of the batteries needed according to the following Table of Power
Consumption:
Table 3 Power Consumption
Item
1
2
3
4
5
6
7
8
9
Description
Approximate Power Consumption
Power consumption
Main System with CPU, IPC
Key Phone
46.2 watt.
1.9 watt.
DSS Console
SK-CPU/2
SK-IPC/2
SK-TRK/2
SK-STI/802
SK-STI/082 (Full Load)
0.8 watt.
4.5 watt.
7.7 watt.
9.6 watt.
1.1 watt.
7.0 watt.
SK-STI/082 (No load) 0.22 watt.
SK-200 Lodging Package Installation & Programming Page 21
Example: System 824 : 8 CO trunks and 24 key telephones
8 trunks=2 SK-TRK/2
24 Extension ports (keyphones)=3 SK-STI/802.
46.2(System) + 9.6x2(2 TRK/2) + 1.1x3(3 STI/802) + 1.9x24 = 114.3 watts.
If using 24Vdc/6A battery (24x6x0.8=115 watt.)
System can operate for 1 hour ( 115
÷÷÷÷
114.3
____
1 hour)
Trunk and Station Cabling
Trunk Cabling
Use 6 Pin 2, Conductor (6P2C) or 6 Pin 4 Conductor 6P4C) line cords to connect SK-TRK/2 - CO1-CO4.
Route the line cords through cabling hole and connect the line cords with the CO/PABX terminals (from CO1 to CO4) of the RJ11C connectors on SK-TRK/2 in the Service Unit. 2-conductor wiring is required.
Refer to the following cabling:
Station Lines Cabling
Use a 16-pair or 25 pair Amphenol Cable to connect SK-STI/802 or SK-STI/082.
Route the cables through cabling hole and connect the Amphenol cable with the terminal (CN1 on SK-STI/802 or SK-STI/082 ). Connect the other end of the cable to the station Terminal Block.
Key Telephone Wiring
1) Use a 25-pair Amphenol cable to connect Station Board (SK-STI/802) and Terminal Block.
2) Connect one end of the Station line (two-pair) to the Terminal Block (66M1-50). Punch down the free conductors from the cables on the connecting block according to standard telephone color code (Table 4.)
3) Connect the other end of the Station line (two-pair twisted cable) to Extension. Terminate the station cable in a
4-wire or 6 wire modular jack. The Modular jack assemblies should be screw-type. Connect the Audio Tip to the GREEN terminal and the Audio Ring lead to the RED terminal. Connect the Data Tip lead to the BLACK terminal and the Data Ring lead to the YELLOW terminal.
Page 22
Table 6-2 Block connection of SK-STI/802 - STI/082
Block Pin Connector Wire Color
14
15
16
17
18
19
8
9
10
11
12
13
3
4
1
2
5
6
7
26
27
28
29
30
31
20
21
22
23
24
25
7
33
8
34
9
35
4
30
5
31
6
32
26
1
27
2
28
3
29
13
39
14
40
15
41
10
36
11
37
12
38
Or-R
R-Gr
Gr-R
R-Br
Br-R
R-Sl
Br-Wh
Wh-Sl
Sl-Wh
R-Bl
Bl-R
R-Or
Wh-Bl
Bl-Wh
Wh-Or
Or-Wh
Wh-Gr
Gr-Wh
Wh-Br
Bk-Br
Br-Bk
Bk-Sl
Sl-Bk
Sl-R
Bk-Bl
Bl-Bk
Bk-Or
Or-Bk
Bk-Gr
Yl-Bl
Yl-Bl
SK-200 Lodging Package Installation & Programming
ID
Audio Tip Circuit 1
Audio Ring Circuit 1
Data Tip Circuit 1
Data Ring Circuit 1
Audio Tip Circuit 2
Audio Ring Circuit 2
Data Tip Circuit 2
Data Ring Circuit 2
Audio Tip Circuit 3
Audio Ring Circuit 3
Data Tip Circuit 3
Data Ring Circuit 3
Audio Tip Circuit 4
Audio Ring Circuit 4
Data Tip Circuit 4
Data Ring Circuit 4
Audio Tip Circuit 5
Audio Ring Circuit 5
Data Tip Circuit 5
Data Ring Circuit 5
Audio Tip Circuit 6
Audio Ring Circuit 6
Data Tip Circuit 6
Data Ring Circuit 6
Audio Tip Circuit 7
Audio Ring Circuit 7
Data Tip Circuit 7
Data Ring Circuit 7
Audio Tip Circuit 8
Audio Ring Circuit 8
Data Tip Circuit 8
Page 23
32 16 Bl-Y Data Ring Circuit 8
NOTE
Port Number Definition: CSN
C= Cabinet No. (1-4)
S= Slot No. (0-9) counted after SK-IPC/2
N= Port No. (1-8) on B3-STU/B3-SLU
Example:
• In Cabinet (1)
• an SK-STI is installed in slot 1 after SK-IPC/2, (First slot is slot 0) and
• a key telephone or a single line telephone is installed in the Fourth (4) port on an SK-STI.
→
The Default Port Number of the station is 114.
Single Line Telephone Wiring
1) Use a cable with a 50-pin connector to connect Single Line phone Board (SK-STI/082, CN1) and terminal block (for example, 66M1-50).
2) Connect one end of the telephone line (one-pair) to the Terminal Block (66M1-50). Punch down the free conductors from the cables on the connecting block according to standard telephone color code (Table 4.)
3) Connect the other end of the Telephone line (one-pair twisted cable) to a Single Line Telephone. Terminate the station cable on a modular jack.
4) Modular jack assemblies should be screw-type terminals. Connect the Audio Tip lead to the GRN terminal.
Connect the Audio Ring lead to the RED terminal.
DSS Console Wiring
The DSS Console wiring is the same as key telephone.
See the above, Key Telephone Wiring.
Refer to the system programming mode:
22-gp-IP
29-st-07
29-CSN-01
29-CSN-03
Flexible DSS Key Group Assignment.
Port Number for DSS Console.
Assign Station Number for DSS Console.
DSS Key Group.
Page 24
SK-200 Lodging Package Installation & Programming Page 25
Page 26
Off Hook Call Announce ( OHCA )
*** Please refer to System Programming mode: 29-csn-02
1) Connect White and Blue of this selected extension port to the 8th port on the same SK-STI/802.
EXAMPLE: (See the following graphic)
To Install OHCA for EXT 11:
Connect the extra two terminals of EXT 11 to the 8th port on the same SK-STI/802 as the following diagram.
SK-200 Lodging Package Installation & Programming Page 27
2) SK-EKT/M cannot receive OHCA.
3) Only one extension can use the
OHCA function at a time for each
SK-STI/802 card.
Optional Cabling
Doorphone Connection:
Two Doorphones may be connected to the SK-200 system.
2-conductor wiring is required.
Connect the Doorphone to the
"DOOR 1" or "DOOR 2" terminal on SK-CPU/2.
Door Switch Connection: (Relay
Connection)
Two Door Switches may be used on the SK-200 system.
Connect the SK-RELAY/2 to the
SK-IPC/2, CN2.
Connect the door switch to the
RELAY terminal on SK-RELAY
2-conductor wiring is required.
Each relay unit contains 3 sets of dry relay contacts (220V/10A).
Page 28
Station Message Detail Recording
(SMDR)
1) The SK-RS232 is used for connecting
Data Terminal Equipment (DTE) such as PC (Personal Computer) for Data
Dump, Version Update, System
Programming, Accounting System (to analyze SMDR message,) or Printer
(to print out SMDR data.)
2) Both SK-CPU/2 and SK-IPC/2 have
RS232 connectors. Connect DTE to either of the cards which has a SK-
RS232 Card.
3) Use DB9 connector of the RS232 cable to connect the RS232 port on
SK-CPU/2 or SK-IPC/2 to the Data
Terminal Equipment (Serial Printer or
Personal Computer).
4) Electrical specification of RS-232:
Baud Rate: 1200 bps
Data Format:
Start bit:
8 bits
1 bit
Parity: None
SK-200 Lodging Package Installation & Programming Page 29
5) Table 5 DB9 Pin Connections to DTE:
Pin
1
2
3
4
Description
CD (Carrier Detect)
RxD (Receive Data)*
TxD (Transmit Data)*
DB9 Pin Connections to DTE
Pin
DTR (Data Terminal Ready)
5
6
7
8
9
Description
GND (Ground)*
DSR (Data Set Ready)*
RTS (Ready To Send)*
CTS (Clear To Send)*
NC (No Connection)
Ext
Background Music and Music on Hold Connection:
Connect the external music sources to the "EX MUSIC1" or "EX MUSIC2" terminal on SK-CPU/2
2-conductor wiring is required.
The terminal "EX MUSIC1" is for Background Music and the terminal "EX MUSIC2" is for Music on Hold.
You can select the external music or internal music by the jumpers setting.
(Please refer to SK-CPU/2 Installation.)
Page 30
ernal Paging Equipment Connection:
Connect the amplifier with the "EX
PAGE" terminal on SK-CPU/2
The output impedance is 600 ohms; the signal level is 250 millivolts (mV).
2-conductor wiring is required.
Refer to the figure 19, External Paging
Equipment Connection:
External Input Sensor:
The Sensor connector on SK-
IPC/2 may be used for the
External Sensor input.
The sensor type may be normally open or normally closed.
2-conductor wiring is required.
Refer to the Figure 20, External Sensor Connection.
Refer to System Programming mode 09 -- Sensor Assignment.
SK-200 Lodging Package Installation & Programming Page 31
Power On and Operational Test
WARNING:
DISCONNECT THE POWER SUPPLY FROM THE AC POWER OUTLET BEFORE
WIRING OR CHANGING ANY WIRING.
Before turning on the power:
Verify that input voltage and input voltage selection jumper on SK-PWR/2 are correct before you power on the system.
Recheck the cabling for wrong connections and fragments that cause short-circuits.
Plug the power cord into a power outlet.
After turning on the power:
On SK-CPU/2 and SK-IPC/2:
Both the red LED1 flash. If any short-circuit occurs, the red LED lights steadily. In order to prevent any system data loss caused by power failure, remove the black plastic insulator from over the Lithium Battery.
Operational Tests
Check each telephone and CO line to verify the outgoing lines are connected properly.
Check that intercom calls can be made from extension to extension.
NOTICE:
ONCE THE SYSTEM IS WORKING PROPERLY, PROCEED TO SYSTEM
PROGRAMMING. (REFER TO THE SYSTEM PROGRAMMING MANUAL.)
Page 32
Programming Initialization
BEFORE ATTEMPTING ANY PROGRAMMING ON A NEW SYSTEM, AFTER ALL CARDS ARE INSTALLED AS
PER THE FINAL CONFIGURATION PERFORM A SYSTEM RESET IN FORM 25 AND VERIFY THAT THE
MEMORY BACKUP BATTERY IS ENABLED. THIS ALSO APPLIES IF A LATER VERSION OF SOFTWARE HAS
BEEN INSTALLED IN THE SYSTEM. DO NOT SKIP THIS PROCEDURE, AS FUTURE PROBLEMS CAN
OCCUR IF NOT PERFORMED.
Entering Program Mode
Password. The system is not password protected when first installed. After setting a Password in Program 13, the system becomes Password protected so that only the person who knows the "password" has access to system database information.
To Enter System Programming Mode From Any Station:
Password Protected
1. Press [PRG], [7]
2. Key in " PASSWORD "
3. Press [SAVE]/[DSS20]
Not Password Protected
1. Press [PRG], [7]
2. Press [SAVE]/[DSS20]
To Enter Programming Mode From The First Key Phone Port In the System.
Password Protected
1. Press [SPK], [7], [0], [7]
2. Enter " PASSWORD "
3. Press [SAVE]/[DSS20]
Unprotected
1. Press [SPK], [7], [0], [7]
2. Press [SAVE]/[DSS20]
Select the PROGRAM MODE:
Enter Form number (01-48).
Enter Sub-Form number.
Enter Item number.
Press [SAVE]/[DSS20] to confirm the selection.
Set data. Press [SAVE]/[DSS20] to confirm the entered data.
Press [SPK] to exit.
Note 1: When in a Program Mode, press [SAVE]/[DSS20] and System will save all valid information in the current form.
Note 2: Busy Tone means that some or all of the data is invalid or out of range. Press [PRG]/[DSS25] and reenter the data.
SK-200 Lodging Package Installation & Programming Page 33
Programming Overlay and Default Soft Key Plans
Once programming mode is accessed the function keys will revert to the default settings to allow programming functions to be set. If there is no [PRG] or [SAVE] in the plan used then [SPK] 7, 0, 7 [SAVE]/[DSS 20] from
Port 11 will enter programming no matter what the soft key plan has set for [DSS 20].
Programming Overlay
SUB Form SUB Form CURSOR CURSOR
DOWN UP LEFT RIGHT
DND/CN
MENU
SAVE
MW/PT
SPD
AT/MIC
The default Soft Key plan for all SK Key Stations in the SK-200 Lodging is Group 3.
Default Soft Key plan for Group 3.
20 21
16
11
PGM
STN 15
17
12
SAVE
STN 16
23
18
13
STN 17
DND/CN
24
19
14
SPD
STN 18
25
20
15
6
1
STN 11
TK:05
TK:01
7
2
STN 12
TK:06
TK:02
8
3
STN 13
TK:07
TK:03
9
4
STN 14
TK:08
TK:04
10
5
FWD
MSG
MSGW/PT
MIC
VOL>
VOL <
Page 34
Group 1 and 3 have hidden features which are accessed by pressing [PGM] then a DSS
key to Access them.
Hidden Features for DSS keys
CHECK
IN
CHECK
OUT
CHARGE
INQUIRY
METERING
RATE
On Line Programming
With this feature, Users can perform programming changes while speaking with an outside party. This is useful for consulting engineering personnel when any problems occur or programming changes are required.
1. During conversation with an outside party.
2. Press [SPD]
→
[PRG]
→
[7].
3. Key in password (If protected)
4. Press [SAVE]/[DSS20] to enter.
Remote Programming using a modem and the system manager.
By using this feature, a user can call the dealers service personnel and allow them to access the programming and make changes from the dealers office via Modem. The users system must have SMDR
(SK-RS232) and RPU (SK-RPI) cards fitted. The baud rate on your modem must be set to 2400.
SK-200 Lodging Package Installation & Programming Page 35
6
7
8
9
10
11
The Procedures are as per the following Table.
1
2
3
Customer's Location
Call the Service Center for help.
4
5
Press [SPD],[prog],[*],
[Hang up the handset].
The LCD will display Remote Programming
Message.
Wait recall from the Service Center.
Answer the recall.
Service Center
Answer the call from the Customer.
Guide Customer to allow the dealer into remote programming.
Switch the conversation to MODEM.
Use System Manager to upload/download
/modify and download the Customer's data.
Use System Manager to recall the Customer.
Switch the conversation back to telephone.
System Manager
It is recommended that dealers use the optional System Manager software to save a copy of System
Programming on disk. This can then be used to reload the system programming from a PC rather than having to manually reprogram after software upgrades or system faults.
Page 36
Remote Programming System to System
By using this feature, a user can call the dealer’s service personnel and allow them to access the programming and make changes from the dealers office via a display phone .Both the dealers system and the users system must be equipped with SMDR (SK-RS232)and RPU (SK-RPI) cards.
The Procedures are as per the following Table.
1
Customer's Location
Call the Service Center for help.
2
3
4
5
6
8
9
10
11
Press [SPD],[prog],[*],
Hang up the handset.
The LCD will display Remote Programming
Message.
LCD will display Remote PGM ready!
Answer the ringing phone
Service Centre
Answer the call from the Customer.
Guide Customer to allow the dealer into remote programming.
Press [SPD],[PROG],[#]
Hang up the handset.
The LCD will display .....Remote PGM
Sys <-----> Sys
LCD will display Remote PGM ready!
Depress [SPD],[PROG], [7] + Password +
[SAVE] to enter program mode.
Program the system
Press [SPK] to quit programming.
Lift handset and talk
Note: Operate the remote programming slowly because data transfer is not reliable at high speed. When the
LCD display changes then you can go on to the next step of the programming.
SK-200 Lodging Package Installation & Programming Page 37
Function
Digits
Function Keys -- for system programming
Previous Subform
Next Sub-form
Cursor Left
Cursor Right
Confirm Setting
* (DTMF Signal)
# (DTMF Signal)
Pulse to DTMF
Pause
Flash
Assign Trunk line
Don't Care (d)
Clear All Digits
Clear Single Digit
Exit Current Form
Exit Programming
Keys
[0] to [9]
[DSS 21]
[DSS 22]
[DSS 23]
[DSS 24]
[SAVE]/[DSS20]
[*]
[#]
[MW/PT]/[DSS15]
[HOLD]
[FL]
[AT/MIC]/[DSS5]
[DND]/[DSS4]
[REDIAL]
[FL]
[PRG/VU]/ [DSS25]
[SPK]
Where to use
Every program
Speed dial
Speed dial, Allowed Area Code,
Allowed Office Code, Voice Mail
Digits.
Common Permitted Code, Ring
Assignment, Console
Assignment,Door Ring
Assignment,
Dial 9 & 87 Group Assignment
Common Restricted Code
Any time that [PGM]/[DSS25] is pressed, any new programming that has not been saved by pressing the
[SAVE]/[DSS20] button is abandoned and the system will return to the MAIN MESSAGE.
Page 38
LCD display - For System Programming
Shows the current programming status to help prevent incorrect data entry.
The LCD display has 2 lines each of 16 digits:
FM-SS-IP
NNNNNNNN
<- Program Status Area
<- System Database Area
MM
SS
: Form Number ( 2 digits)
: Sub-Form Number ( 2, 3, or 4 digits)
IP : Item Pointer for entering data.
NNNNNNN : Data Entry Area.
SK-200 Lodging Package Installation & Programming Page 39
Station Numbering Plan:
System Default
On the SK-200 the station numbering will automatically change to 3 digits when station numbers exceed the allowed 2 digit numbering scheme.
Change Station Numbering Plan
If the original numbering plan is two-digit:
Change to three digits: The system will add 100 to Station numbers.
(Example: 23 will become 123).
Change to four digits: The system will add 1000 to Station numbers.
(Example: 23 will become 1023).
If the original numbering plan is three-digit:
Change to four digits: Add 1000 to the Station numbers.
(Example: 123 will become 1123).
Change to two digits : Delete the first digit
(Example: 123 will become 23).
If the original numbering plan is four-digit:
Change to three digits: Delete the first digit
(Example: 1234 will become 234 ).
Change to two digits : Delete the first two digits
(Example: 1234 will become 34 ).
Available station numbers
two-digit:
three-digit:
four-digit:
10 to 69
100 to 699
1000 to 6999
Programming Applicable to Station Numbering
Program 41-st-07
05-03-06
43-(csn)-01
Show the port number (csn)
Assign Station digit length
Enter a Station number for the port
Page 40
Programming Description
Program 01-tk-IP:Ringing Assignment - Day Service
01-tk-IP FLX DAY
111 112 113 114 tk = (01-40)
IP = Item (01-16) Assigned station number.
General:
This program assigns each incoming line to ring the programmed stations. The ringing methods can be
COMMON AUDIBLE (All stations will ring simultaneously), LINEAR (ring the first available station),
CIRCULAR (Ring the next station following the last station who just answered an incoming call) or HUNT
(Ring the first assigned station for a set period of time (program form 05-08-01) then if no answer ring the next ring assigned station then the next etc.) See Program Form: 35-tk-07 to assign.
Description:
1. This program sets ringing while the system is in Day Service.
2. The station number can be 2,3,4 digits.
3. A total of 16 stations can be assigned to ring for each trunk.
4. If the location is to be assigned to no station, the location value is set to " 0 ".
5. To clear all entries press [REDIAL].
Program 02-tk-IP :Ringing Assignment - - Night Service
02-tk-IP FLX NIG
111 112 113 114 tk = (01-40)
IP = Item Pointer (01-16)
←
Assigned station number.
General:
This program assigns each incoming line to ring the programmed stations. The ringing methods can be
COMMON AUDIBLE (All stations will ring simultaneously), LINEAR (ring the first available station),
CIRCULAR (Ring the next station following the last station who just answered an incoming call) or HUNT
(Ring the first assigned station for a set period of time (program form 05-08-01) then if no answer ring the next ring assigned station then the next etc.) See Program Form: 35-tk-08 to assign.
Description:
1. This program sets Night Service ringing.
2. The station number can be 2,3,4 digits.
3. A total of 16 stations can be assigned to ring for each trunk.
4. If the location is to be assigned to no station, the location value is set to 0.
5. To clear all entries press [REDIAL].
SK-200 Lodging Package Installation & Programming Page 41
Program 03-nn-IP : Door Ring Assignment
03-nn-IP Door
nn = Door phone (01-02)
111 112 113 114
IP = 01-08 Assigned station number.
General:
This program assigns the door phone to ring the programmed stations.
Description:
1. There are two door phone ports available in the SK-200.
2. Eight stations can be assigned to ring for each door phone.
If the first position is entered as 99 (two digit numbering), 999 (three digit numbering) or 9999 (four digit numbering) all phones will ring.
3. To clear all entries press [REDIAL].
4. Door phone ringing time is set in Form 05-11-07.
5. Door Relay Unlock Time is set in Form 05-12-04.
6. Door phone Ringing frequency is set in Form 05-03-08.
Program 04-gp-IP : Console Assignment
04-gp-IP Console
gp = Station group (01-08)
111 112 113 114
IP = 01-04 Assigned station number(2 to 4 digits).
General:
This program permits the selection of the consoles (Operators) in each station group.
Description :
1. There are 8 console groups available.
2. A total of four stations can be set to be the console in each group.
3. The first assigned station is the master console.
4. To clear all entries press [REDIAL]. Do this in all unused groups.
5. It is recommended that only one console is used.
Page 42
Program 05-01-IP : System Timing Parameters - 01
05-01-IP SYS PAR
IP = 01-08
1 1 1 1 4 2 2 1
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
DisplayD ata
0-9
0-9
0-9
0-9
0-9
0-9
0-9
0-9
Programming Data Description
Hold Recall Time
Exclusive Hold Recall Time
Hold recall Timeout
DISA Access Delay Time
Busy Remind Cycle Time
Pause Time
DTMF Generation Time
Call Forward No Answer TRF. Time
Timing
Table
A
A
A
C
C
D
E
Default
1=60 Secs.
1=60 Secs.
1=60 Secs.
1=2 Secs
4=8 Secs.
2=800 Ms.
2=83 Ms.
1=20 Secs
General:
This programming section allows the programmer to assign different system parameters.
Description:
Item 01 - Hold Recall Time:
This parameter sets the time duration from when Hold is initiated to when the held call starts to ring (recall) the station.
After a pre-determined recall time (see 05-01-03: Hold Recall Timeout), if the station still does not answer, the held call will automatically transfer to the Console.
Item 02 - Exclusive Hold Recall Time:
This parameter sets the time duration from when Exclusive hold is initiated to when the held call starts to recall the station.
After a pre-determined recall time (see 05-01-03: Hold Recall Timeout), if the station still does not answer, the held call will recall to the Console in addition to the holding station.
Item 03 - Hold Recall Timeout:
This parameter sets the time between a call recalling to a holding or transferring station and then recalling to the console if unanswered.
See timing table A for parameters of these 3 features.
SK-200 Lodging Package Installation & Programming Page 43
Item 04 - DISA Access Delay Time:
This parameter sets the time duration that a DISA trunk will ring prior to connection with return dial tone or
VSU message. (Stations can answer during this time.)
0 = Automatic connection, no ring to the stations
1-8 = Automatic connection after 2-254 seconds ringing.
See timing table C for parameters for this feature.
Item 05 - Busy Remind Cycle Time (Off-Hook Ringing):
This parameter selects the length of time an incoming trunk call rings the system before a busy ring assigned station is reminded of the call. A muted, one-second ring will be given to the station through the speaker to indicate the call. The tone will be repeated every busy remind time interval.
This parameter also sets the timing for the SLT Camp-On feature (see Form 05-08-03 to extend timing for
SLT Camp on tone) and the camp on tone for key stations.
See timing table C for parameters of this feature.
Item 06 - Pause Time:
This parameter sets the system pause time duration for speed dial entry, trunk access time and voice mail call forwarding tone delay.
See timing table D for parameters of this feature.
Item 07 - DTMF Generation Time:
This parameter permits the selection of DTMF Generation output time. The generation time may need to be lengthened to access some Voice Mail or answering machines.
See timing table E for parameters of this feature.
Item 08 - Call Forward No Answer Transfer Time:
This parameter sets the duration between calling a station which has set call forward no answer, and the transfer of the call to the station to which it has been forwarded.
0 = 10 seconds
5 = 60 seconds
1 = 20 seconds
6 = 70 seconds
2 = 30 seconds
7 = 80 seconds
3 = 40 seconds
8 = 90 seconds
4 = 50 seconds
9 = 100 sec.
TIMING TABLE
Table 0
A 30
C
D
E
0
400
50
1
60
2
600
66
2
90
4
800
83
3
120
6
1000
100
4
150
8
1200
115
5
180
15
1400
132
6
210
30
1600
149
7
240
60
1800
164
8
253
120
2000
180
9
∞
254
2200
195 unit sec. sec.
ms.
ms.
Page 44
Program 05-02-IP : System Timing Parameters - 02
05-02-IP SYS PAR IP = 01-08
5 5 1 5 4 1 2 4
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-9
0-9
0-9
0-9
0-9
0-9
0-9
0-9
Programming Data Description
SLT Dial Tone Timeout
SLT Inter-Digit Timeout
Auto Redial Ringing Time
SLT Release Signal
Flash Time - Key Phone
SLT Hold Signal
Ring On Time
Ring Off Time
Timing
Table
C
C
B
I
G
J
F
Default
5=15 Secs
5=15 Secs.
1=10 Secs
5=800 Ms.
4=440 Ms.
1=100 Ms.
2=240 Ms.
4=4 Secs
Description:
Item 01 - SLT Dial Tone Timeout:
This parameter is for Single Line Telephones. If a key is not pressed before the assigned time period expires when Dial Tone is given, a Busy Tone will be heard.
Item 02 - SLT Inter-Digit Timeout:
This parameter is for Single Line Telephones. If the interval between digits dialed exceeds the assigned time period, a Busy Tone will be given.
See timing table C for parameters of these features.
Item 03 - Auto Redial Ringing Time:
This parameter is the time duration for which the system will redial the telephone number automatically and then hang up during Auto Redial.
1 = 10 seconds 2 = 20 seconds 3 = 30 seconds 4 = 40 seconds 5 = 50 seconds
6 = 60 seconds 7 = 70 seconds 8 = 80 seconds 9 = 90 seconds
Off Hook
Auto-Redial Pause Time (Program
05-05-08), Y seconds
Off Hook
Auto-Redial Ringing Timer Auto-Redial Ringing Timer
On Hook
Item 04 - SLT Release Signal:
This parameter is the time duration of depressing the hook switch of an SLT that the system will see as a hang up, the system will take it as a hold signal if less than this time but longer than the SLT hook flash time.
SK-200 Lodging Package Installation & Programming Page 45
See timing table B for parameters of this feature.
Page 46
Item 05 - CO Line Flash Time - Key Phone & SLT:
This parameter permits the selection of Flash time for Key stations when pressing the [TR/FL] key or a single line phone that presses flash and then dials 800 while connected to an outside line. After dialing 800 the flash signal will be sent to the CO line and the SLT phone will reconnect to the CO line.
See timing table I for parameters of this feature.
Item 06 - SLT Hold (Flash) Signal:
This parameter permits the selection of the Flash time from a single line telephone that the system will see as a Hold signal if the time is greater than the hold signal but less than the SLT release time.
See timing table G for parameters of this feature.
DURING
CONVERSATION
HOOK PRESSED-Period B HOOK RELEASED
DURING
CONVERSATION
Period B < SLT Release Time
HOOK PRESSED-Period B
Period B > SLT Release Time
Hold
HOOK RELEASED
Hang Up
Item 07 - Ring On Time:
This parameter allows the system to identify Ring On Time Interval from the Central Office. This is how long a ring signal is required to indicate an incoming CO call.
See timing table J for parameters of this feature.
Item 08 - Ring Off Time:
This parameter allows the system to identify Ring Off Time Interval from the Central Office. A period longer than this setting will indicate to the SK-200 that the ringing call has been abandoned.
See timing table F for parameters of this feature.
TIMING TABLE
Table 0 1 2 3 4 5 6 7 8 9 unit
B
C
F
G
I
J
200
0
2
80
80
120
200
2
2
100
120
160
300
4
2
200
200
240
400
6
3
300
280
360
600
8
4
400
440
440
800
15
5
500
640
560
1000
30
6
600
840
640
1200
60
7
700
1040
760
1400
120
8
800
1240
840
1600
254
9
900
1440
960
ms. sec. sec.
ms.
ms.
ms.
SK-200 Lodging Package Installation & Programming Page 47
Program 05-03-IP : System Timing Parameters - 03
05-03-IP SYS PAR IP = 01-08
0 0 0 9 0 2 0 7
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-1
0-1
0-1
0-9,d
0-9
2-4
0-7
0-9,d
Programming Data Description
Make / Break Ratio
Automatic Trunk Search
Intercom Call Signaling Method
PABX (Centrex) Outgoing Code
Toll Access Code
Station Numbering Plan
Intercom Dial Tone Pattern
Door Phone Ringing Frequency
Default
0=33/66
0=Yes
0=Voice
9=9
0=0
2=2
0=Steady
7=Freq 7
Description:
Item 01 - Make/Break Ratio:
This parameter permits the selection of a Make/Break Ratio for Dial Pulse signaling. The default setting of
33/66 is correct for North America.
0 = 33/66 1 = 40/60
Item 02 - Automatic Trunk Search:
This parameter allows the system to search for an available trunk according to the assigned dial 9 trunk group when automatic dialing features are used; i.e., Speed Dial, Save Redial, Redial, etc.
0 = Allowed 1 = Not Allowed
Item 03 - Intercom Call Signaling Method:
This parameter selects the Intercom calling method. The user can still override this selection by dialing 3 after initiating an intercom call. Individual stations can be set to automatic microphone switch-on in Form
46-st-03 and thus override the system wide ring method.
0 = Voice Signaling 1 = Ring Signaling
Item 04 - PABX (Centrex) Outgoing Code: (Refer to Program 35-TK-01):
Page 48
This parameter assigns the PABX outgoing call access code for Redial and Save Redial when the system is installed behind a PABX.
It is used when Trunk Lines are set to be PABX lines in Form 35-TK-01.
This assignment also enables the system to identify whether the user's dialing is a PABX's Intercom call or an Outgoing call for toll restrictions.
Item 05 - Toll Access Code:
This parameter assigns the long distance call access digit. This parameter affects the operation of SMDR operation in regard to recording or not recording local calls. See Form 14-01-03. With 8 digit numbering plans in use this parameter is not always useable.
Item 06 - Station Numbering Plan:
This parameter assigns the number of digits used for the station numbering plan. 2, 3, or 4 digits may be used. The SK-200 system will initially set the digits to 2 unless the number of stations installs exceeds the allowed numbering plan in which case the digit length will be set to 3.
Item 07 - Intercom Dial Tone Pattern:
This parameter assigns the pattern of intercom dial tone. If the parameter is set to 1 or 2 then analogue phones will receive the special DND tone if call forward or DND has been set for that extension. Item 2 is particularly designed for use when there is a Voice Mail system connected to the system as some Voice mail units have problems with the broken dial tone.
SK-200 Lodging
Value / Function
0 Steady Tone
1 Interrupted Tone
2 Steady Tone
Yes
Yes
No
3
4
5
6
7
Interrupted Tone
Steady Tone
Interrupted Tone
Steady Tone
Interrupted Tone
No
Yes
Yes
No
No
Special Dial Tone for
Message Waiting
No
No
No
No
Yes
Yes
Yes
Yes
Item 08 - Door Phone Ring Pattern:
This parameter allows for different ring patterns or frequencies for the Door Phone.
0
1-8
=
=
Continuous ring
Ring using Ring frequency 1 to 8 of the SK1 Phone
9 = Ring tone 250 ms on 250 ms off 250 ms on 750 ms off 500 ms on 500 ms off.
SK-200 Lodging Package Installation & Programming Page 49
Program 05-04-IP : System Timing Parameters - 04
05-04-IP SYS PAR
IP = 01-08
1 1 0 0 0 1 0 0
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-2
0-1
0-8
0-1
0-9
0-9
0-1
0-3
Programming Data Description
Baud Rate For RS232 Port
Dial 9 Flag
Action for Call Duration Limiting
12/24 Hours Clock
Flash Delay Time
Speed Dialing Distribution
Single Digit Intercom
Message Waiting Method - Single Line Phones
Default
1=2400
1=Enable
0=Warning
0=12 Hours
0=No Delay
1=200 Sets
0=Disable
0=No Ring
Description:
Item 01 - Baud rate For RS232 Port:
This parameter sets the Baud rate of the RS232 port of the system.
0 = 1200 1 = 2400 2 = 3600
Item 02 - Dial 9 Flag:
This parameter sets if a station can access an outgoing line by dialing 9. If this parameter is disabled the station can still access an outgoing line by pressing a line key.
0 = Can not access dial 9 feature 1 = Can access dial 9 feature
Item 03 - Action for Call Duration Limiting:
This parameter decides what action will be taken if a station has limit call duration enabled in Form 40nnnn-03. Settings 0 to 3 are for outgoing calls only. The outside party will also hear the warning tone.
0 & 5
1 & 6
2 & 7
=
=
=
Continuous Warning Tone after Timeout.
1 second Warning Tone for each cycle of Limit Call Duration
At 10 seconds before Timeout, 1 second Warning Tone, At 5 seconds before timeout, continuous Warning Tone, At timeout the line is released.
At 1 minute before timeout, 1 second warning tone, At 30 seconds before timeout, continuous
Page 50
3 & 8 = warning tone, At timeout the line is released.
Item 04 - 12/24 Hour Clock:
0 = 12 Hour Clock 1 = 24 Hour Clock
Item 05 - Flash Delay Time:
This parameter defines the period after the user has lifted the handset on a single line phone before the flash signal can be sent.
0 = No Delay after off hook 1-9 = Delay 1- 9 seconds after off hook
Item 06 - Speed Dialing Distribution:
This parameter sets the number of speed dial numbers allocated to the system speed dial. Adding extra numbers to system Speed Dial reduces the number of personal Speed Dial numbers available to share between individual stations.
0 =
1 =
2 =
System 100 (100 to 199)
System 200 (100 to 299)
System 300 (100 to 399)
Individual 900/400 (SK-200)
Individual 800/300 (SK-200)
Individual 700/200 (SK-200)
3
4
5
6
7
=
=
=
=
=
System 500 (100 to 599)
System 600 (100 to 699)
System 700 (100 to 799)
System 800 (100 to 899)
System 900 (100 to 999)
Individual 500/100 (SK-200)
Individual 400/000 (SK-200)
Individual 300 (SK-200)
Individual 200 (SK-200)
Individual 100 (SK-200)
Numbers after backslash indicate sets available with name feature enabled
Item 07 - Single Digit Intercom:
Single digit intercom allows the stations to call up to 5 other stations by dialing one digit only (1 to 5). This feature is for the Hotel / Motel Environment. Up to eight different groups may be programmed. If a group is not programmed with any entries then stations which are in the same number station group will be able to make intercom calls without dialing the room to room dialing prefix (6).
0 = Disable 1 = Enable
Item 08 - Message Waiting Method for Single Line Phones:
On the SK-200 if the setting is 0 and the SLUM (message waiting lamp) card is installed, the message wait will be 90V DC signaling. to drive the neon light on properly equipped single line telephones.
If the setting is Ring, the phone will receive 30 seconds intercom ringing every 5 minutes until the station answers.
SK-200 Lodging Package Installation & Programming Page 51
If the setting is Voice Message, the station which is left a message will hear the voice message which is stored by the console after answering the message waiting.
Page 52
If the setting is 250 Ms. ring the single line phone will receive a 250 Ms. ring burst every 5 minutes. This is for use with special handsets designed to receive the “pling” signal to turn on message lamp.
0 = No Message Waiting / 90 V Neon Enable
2 = Voice Message 3 = 250 Ms. Ring
1= Ring
4 = Ring once
SK-200 Lodging Package Installation & Programming Page 53
Program 05-05-IP : System Timing Parameters - 05
05-05-IP SYS PAR
IP = 01-08
1 0 0 0 0 1 1 0
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-3
0-1
0-9
0-9
0-7
0-1
0-9
0-9
Programming Data Description
Morning Call Type
Meter Pulse Detect
Speed Dial Unrestricted-1
Speed dial Unrestricted-2
Name Feature For Extensions, Trunks, Speed dials
Dial Tone Detection
Auto Redial Times
Auto Redial Pause Time
Default
1=Music
0=Enable
0=0
0=0
0=Disable
1=Enable
1=2 Times
0=10 Secs.
Description:
Item 01 - Morning Call:
This parameter is for the Hotel/Motel environment to decide what an extension will hear upon receiving a wake up call and whether the Morning call will be recorded to allow printout on request. If Fidelio PMS is enabled (05-13-01) and Morning call history is enabled then the Front Office computer will automatically print out unsuccessful Morning calls for Immediate attention.
0
1
=
=
Voice message (requires VSU)
Back-ground music or DND tone.
2
3
=
=
VSU + Record Morning Call History via SMDR
Back-ground music or DND tone + Record Morning Call History via SMDR
Each station can be set in 44-st-08 to decide whether they hear Background Music or DND tone.
Item 02 - Metering Detector:
If setting is Enable, the system will detect the metering signal from the Exchange during the conversation.
Depending on the Exchange's equipment, the metering signal may be 50 Hz (obsolete), or 12 KHz, or 16
KHz. (currently 12 KHz detection is available new) The SMDR print out will have one more column to indicate the total pulses which are detected by the system during the conversation. This feature is enabled in default and there is no need to disable it. On very old exchanges where obsolete 50 Hz metering is in use it may be necessary to set Meter Pulse detect delay time in Form 05-07-08 to detect local call meter pulses.
Page 54
0 = Enable 1 = Disable
Item 03, 04 - Speed Dial Unrestricted 1, 2:
If 03, 04 settings are A, B, then the speed dial codes from 100 to AB0 are not toll restricted. For example if the settings are 1 and 1 then Speed dials up to 110 can be used by stations whether they conflict with toll restrictions or not. Individual stations can be restricted from using this feature in Form 45-st-07.
If 03, 04 settings are set to 0, 0, then all speed dial codes are toll restricted if the station using the speed dial is restricted.
Item 05 - Name Function:
This parameter enables the naming feature for trunks, extensions and speed dials.
Features \ Values
Display Name instead of number for
0 1
X
2 3
X
Extension
Directory Dial for Speed Dial
Directory Dial for Extension
X X
5
X
X
7
X
X
X
Note: When any of the above features are enabled the total number of speed dial sets will be reduced by 500 (SK-200)
Item 06 - Dial Tone Detection:
If setting is enable, then the system will send out the dialing signals after the system detects the Dial Tone which is sent from the exchange, if dial tone is not detected by the system then dialing signals will not be sent out.
If setting is disable, then the system will send out dialing signals whether Dial Tone is detected or not.
0 = Disable 1 = Enable
Item 07 - Auto Redial Times:
This parameter is to set the number of auto redial times which the system will attempt.
0 = Disabled 1 = 10 2 = 20 3 = 30
5 = 50 6 = 60 7 = 70 8 = 80
4 = 40
9 = 90
Item 08 - Auto Redial Pause Time:
This parameter is the time duration between the system hanging up an auto redial attempt and starting to redial automatically.
0 = 10 Seconds
5 = 60 Seconds
1 = 20 Seconds
6 = 70 Seconds
2 = 30 Seconds
7 = 80 Seconds
3 = 40 Seconds
8 = Seconds
4 = 50 Seconds
9 = 100 Seconds
Auto-Redial Pause Time (Program
SK-200 Lodging Package Installation & Programming Page 55
Off Hook
Auto-Redial Ringing Timer
05-05-08), Y seconds
On Hook
Off Hook
Auto-Redial Ringing Timer
Page 56
Program 05-06-IP : System Timing Parameters - 06
05-06-IP SYS PAR
1 0 0 0 0 3 0 0
IP = 01-08
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-9
0-9
0-1
0-9
0-9
0-9
0-1
0-2
Programming Data Description
TRF Busy Recall Timeout
TRF Idle Recall Timeout
DISA & ACD-1 VSU Grouping (SK-200)
Polarity Reversal
Operator Code
Unsupervised Conference And ECF Time
Setting
Hold Method for SLT
Station Hunting Group Ring Method (not used on
SK-200)
Timing
Table
A
A
Default
1=60 Secs.
0=30
0=Disable
0=Disable
0=0
3=3 Min
0=Flash
0=Disable
Description:
Item 01 - Transfer Busy Recall Timeout:
This parameter sets the time duration between transferring a call to a busy party and automatic transfer back to the transferring party when the called party is busy.
Item 02 - Transfer Idle Recall Timeout:
This parameter sets the time duration between transferring a call to a station and automatic transfer back to the transferring party when the called party does not answer.
See timing table Grade A for parameters of these 2 features.
Item 03 - DISA and ACD-1 VSU Grouping:
This parameter enables voice channel grouping for DISA and ACD-1. The groups that VSU channels are assigned to is set in Form 19-GP-09. Trunks will also need to be assigned to the same groupings in Form
36-GP.
0 = Disable 1 = Enable
SK-200 Lodging Package Installation & Programming Page 57
Item 04 - Polarity Reversal:
This parameter is to enable the Polarity Reversal detection feature for incoming caller hang up detection in
North America. See Form 14-01-08 for SMDR setting. Telco will need to enable polarity reversal at the CO.
0 = Disable
1 = Enable for 1 polarity reverse signal
2-9 = Delay for 1-8 Seconds and then detect Polarity Reverse Signal
Item 05 - Operator Code:
This parameter is to set whether to dial "0" or "9" for the operator or for accessing a CO. line.
1-9
0
=
=
Dial "9" for operator, "0" for CO. line.
Dial "0" for operator, "9" for CO. line.
Item 06 - Unsupervised Conference and ECF Time Setting:
This parameter sets the time that the system will allow an Unsupervised Conference or External Call
Forward to continue before sending a warning tone to the parties and then disconnecting the call. If either party sends a DTMF digit (0-9) to the system the timer will reset and allow the call to continue for the time setting.
0 = No Limit 1 = 1 Minutes 2 = 2 Minutes
3 = 3 Minutes 4-9 = 4 Minutes
Item 07 - Hold Feature for SLT:
This parameter is to set whether Single Line Telephones use [FLASH] (or [Hook-switch]) or [FLASH, 7] (or
[Hook-switch, 7]) to place a call on Hold.
0
1
=
=
Normal -----> Using [FLASH] or [Hook-switch] to put a call on Hold.
Alternate --> Using [FLASH, 7] or [Hook-switch, 7] to put a call on Hold.
Item 08 - Not Used:
TIMING TABLE
Grade 0
A 30
1
60
2
90
3
120
4
150
5
180
6
210
7
240
8
253
9
None unit sec.
Page 58
Program 05-07-IP : System Timing Parameters - 07
05-07-IP SYS PAR IP = 01-08
0 0 2 0 0 0 0 0
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-1
0-1
2-4
0-7
0-1
0-9
0-9
0-1
Programming Data Description
Intercom Searching
SLT Toll Override Prevention
Reserved
DISA Transfer To Console - No Digits Dialed
Key Phone Toll Override Prevention
SMDR Digit Mask
Meter Pulse Detect Delay Time
Reserved
Timing
Table
K
Default
0=Disable
0=Disable
2
0=Enable
0=Disable
0=Disable
0=0 Ms.
0
Description:
Item 01 - Intercom Searching:
If setting is enable, when calling an internal station which is busy or does not answer, pressing [4] will call the next station which is in the same station group as the called station. If setting is disable then there will be no transfer.
0 = Disable 1 = Enable when/busy
2 = Enable no/answer 3 = Enable busy /no answer
Item 02 - Toll Override Prevention from quick dial (Calling Proof)
To protect toll override control when a Key Phone selects a trunk and quickly dials one digit and overriding the toll control. If Enabled then after selecting a trunk the first digit dialled will be delayed one pause interval
0= Disable 1= Enable
Item 03 - Reserved:
Item 04 - DISA Recall To Console - No Digits Dialed:
If this function is activated, when a DISA call is answered but the caller does not dial any digits or a station number the system will recall the Operator after the assigned DISA Transfer Time no dialing (Form 05-08-
07). If this function is disabled the call will be disconnected after Transfer Time No Dialing elapses.
SK-200 Lodging Package Installation & Programming Page 59
0 = Recall To Operator 1 = No Recall To Operator 2-7 = See table on following page
Page 60
Value
2
3
4
5
6
7
Note
No dialing after the first voice announcement of VAC.
X
O
X
O
X
O
X = Transfer the incoming call to console.
O = System will announce the VAC function 6 to the incoming call if time for no dialing exceeds the form 05-08-07.
And then, system will release the outgoing call if time for no dialing exceeds the form 05-08-07 again.
The VAC has already announced that the called station is busy/ no answer.
O
O
X
X
O
O
X = See Form 46-st-04
O = See Form 46-st-04. If it is no recall to console, system will announce the
VAC function 6 to the incoming call if time for no dialing exceeds the form 05-
08-07. And then, system will release the outgoing call if time for no dialing exceeds the form 05-08-07 again.
The VAC has already announced the null or number not received completely.
X
X
O
O
O
O
X = System will transfer the incoming call to console if time for no dialing exceeds the form 05-08-07.
O = System will announce the VAC function
6 to the incoming call if time for no dialing exceeds the form 05-08-07. And then, system will release the outgoing call if time for no dialing exceeds the form 05-08-07 again.
Item 05 - Toll Restriction Override Prevention:
If the setting is Disabled, after accessing a line a user will be able to use a DTMF generator directly to the network rather than the DTMF signal generated within the KSU. The result of this is that Toll restriction can be over-ridden.
If setting is Enable, then no audio will be sent from the handset until 3 digits are received by the KSU from the key station dial pad preventing Toll restrictions being overridden. This parameter will be automatically disabled on any lines which are set to Pulse dial.
0 = Disable 1 = Enable
Item 06 - SMDR Digit Mask:
If setting is "0", then the full length of the telephone number will be output to the SMDR. If setting is n, then the length of the telephone number will be n digits long. n = 0 to 9
Item 07 - Meter Pulse Detect Delay Time:
If this parameter is enabled the system will wait at the end of a call for the meter pulse to be sent from the
Central Office. During this delay time the line is not able to be accessed. This is necessary for some older
COs and only affects local call metering.
This parameter is also used to insert a pause between a line being released and being able to be reselected for outward dialing. See timing table grade K for parameters for this feature.
Item 08 - Reserved:
TIMING TABLE
Grade 0 1 2 3 4 5 6 7 8 9 unit
SK-200 Lodging Package Installation & Programming Page 61
K 0 600 1000 2000 3000 4000 5000 6000 7000 8000 m sec.
Page 62
Program 05-08-IP : System Timing Parameters - 08
05-08-IP SYS PAR
IP = 01-08
0 0 0 0 7 0 0 1
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-9
0-1
0-9
0-1
0-8
0-9
0-9
0-2
Programming Data Description
Hunt Time Setting
DSS Access To Other Trunk Group
SLT Camp On Tone
DISA/DID Transfer Group(No Answer)
SLT Programming digit
DISA /DID TRANSFER Time No Answer or Busy
DISA Transfer Time No Dialing
Station Hunt Group Ring Method/SK-200
Timing
Grade
C
Default
0=0 Secs
0=Enable
0=Disable
0=Station Grp
7=7 + Code
0=8 Secs
0=0 Secs.
1=Linear
Description:
Item 01 - Hunt Time Setting:
If setting is n, Then when an incoming call rings the first ring assigned extension and that extension is busy, after n seconds the call will ring the second of the ring assigned extensions. If the 2nd extension is busy the call will go to the 3rd extension immediately. All stations which have been passed by the ring assignment will receive off hook busy remind. Up to 16 stations can be in the ring hunt group. If the setting is 0 then only the first ring assigned station will ring.
See timing table C for parameters of this feature.
Item 02 - DSS Access To Other Trunk group:
This feature enables or disables the ability of stations to use a DSS key to answer Ringing CO lines not in their own group.
0 = Enable. 1 = Disable
Item 03 - SLT Camp On Tone:
This feature enables a tone to indicate call waiting for a busy Single Line phone and sets the interval between tones. The interval between tones will be the Off Hook Busy Remind Interval (t) x by the setting in this parameter. Off Hook Busy Remind Time is set in Form 05-01-05.
0 = Disable 1 = t x 1 2 = t x 2 3 = t x 3 4 = t x 4
SK-200 Lodging Package Installation & Programming Page 63
5 = t x 5 6 = t x 6 7 = t x 7 8 = t x 8 9 = t x 9
Item 04 - DISA Transfer Group:
This parameter decides to which group an unsuccessful DISA call will be transferred if the called station has transfer enabled in Form 46-st-04.
0 = Console for the Called Station's group 1 = Console for the Incoming Trunk's group
Item 05 - SLT Programming Digit:
This feature changes the programming digit used by an Analogue phone to perform its programmable features. For example call forward is normally 701, If this parameter is set to 3 the call forward code will be
301. If the setting is 0 then the analogue phones cannot do programming. If the setting is 8 it is necessary to press [*][#] before accessing programming or dialing any 8 codes. This will allow the use of digits 1 to 8 as the first digit of a station number.
0 = Disable 1 = 1xx 2 = 2xx 3 = 3xx
4 = 4xx 5=5xx 6=6xx 7=7xx
8 = [*][#][7] for programming, [*][#][8] to access functions beginning with 8.
Item 06 - DISA /DID Transfer Time No Answer:
An incoming call is answered by the DISA voice message and transferred to the called extension or a DID call is transferred to the called extension. If the called extension does not answer after this time duration the voice card will announce the status of the station (no answer) or if the station is busy will announce the status (busy) immediately and then retry the station the number of times set in Form 05-11-06 and depending on the settings for individual stations in Form 46-st-03 will also transfer the call to the console of the group specified in Form 05-08-04, transfer the call to the console only or disconnect the call.
0 = 8 Seconds 1 = 16 Seconds 2 = 24 Seconds 3 = 32 Seconds 4 = 40 Seconds
5 = 48 Seconds 6 = 56 Seconds 7 = 64 Seconds 8 = 72 Seconds 9 = 80 Seconds
Item 07 - DISA Transfer Time No Dialing:
This parameter sets the time that a DISA call will wait after the voice message is completed before transferring to the console if no digits are dialled by the caller. Do not set this to less than about 3 seconds for normal operation.
0 = Immediate
5 = 5 Seconds
1 = 1 Second
6 = 6 Seconds
2 = 2 Seconds
7 = 7 Seconds
3 = 3 Seconds
8 = 8 Seconds
4 = 4 Seconds
9 = 9 Seconds
Item 08 - Hunt Group Ring Method:
TIMING TABLE
Grade 0 1 2 3 4 5 6 7 8 9 unit
Page 64
C 0 2 4 6 8 15 30 60 120 sec.
SK-200 Lodging Package Installation & Programming Page 65
Program 05-09-IP : System Timing Parameters - 09
05-09-IP SYS PAR
0 1 0 0 0 0 0 0
IP = 01-08
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-7
0-1
0-9
0-9
0-1
0-9
0-9
0-9
Programming Data Description
Paging Tone and Loop Start Control (SK-200)
Busy Console Queuing (Intercom Calls)
Clear Forward - Loop Break detection
DISA Busy Tone Detection
Save Redial Numbers - 1 or 6
ACD-1 Enable Time
ACD-1 Segment 2 Recall Time
ACD-1 Release Time
Timing
Grade
O
N
P
Default
0=Normal
1=Enable
0=Disable
0=Disable
0=1
0=5 Secs
0=Disable
0=No Release
Description:
Item 01 - External Paging Control:
This parameter enables or disables the start tone and loop start for external paging equipment
Setting
0
Internal Page with Page Tone
Yes
External Page with Page Tone
Yes
Page Equipment is Loop Start
No
1 Yes No No
2 Yes Yes Yes
3 Yes No Yes
4 No Yes No
5 No No No
6 No Yes Yes
7 No No Yes
Page 66
Item 02 - Console Queuing:
This feature enables the busy console(s) to have an intercom call(s) queued to it(them). If the station dials the operator (by 0 or 9) and all the consoles are busy, the system will put this call in the queue to wait for the operators to be free. The calling station will hear ring back tone instead of busy tone and the first operator in the group will receive the Busy Remind Signal. The first operator to go on-hook will receive the call.
0 = Disable 1 = Enable
Item 03 - Clear Forward Signal Detection - Loop Disconnect
This feature enables loop disconnection as a Clear Forward Signal. This parameter sets the minimum open loop time that the system will recognize as a disconnect.
0 = Disable 1 = 80 ms 2 = 160 ms 3 = 240 ms 4 = 320 ms
5 = 400 ms 6 = 480 ms 7 = 560 ms 8 = 640 ms 9 = 720 ms
Item 04 - DISA Busy Tone Detection:
This feature allows the system to recognise busy tone from the exchange line during DISA operation for clearing down the call.
Type 1 = busy tone is 250 ms. on, 250 ms. off.
Type 2 = 500 ms. on and 500 ms. off.
Type 3 = Continuous busy tone (>3.2 seconds).
Type 4 = 375 ms. on and 375 ms. Off
0 = Disable 1 = Type 1
5 = Type 1 and 3 6 = Type 2 and 3
2 = Type 2
7 = Type 1, 2 ,3.
3 = Type 1 and 2
8 = Type 4.
4 = Type 3
Item 05 - Save Redial Numbers - 1 or 6:
If this parameter is enabled then the user will be able to enter 6 numbers in the Save/Redial scratch pad and then automatically dial them in sequence.
0 = 1 Save/Redial 1 = 6 Save/Redials
Item 06 - ACD-1 Enable Time:
This parameter is to set the time duration before the system answers an incoming call when the ring assigned station(s) are busy, if a VSU card is fitted. The incoming call will show as a normal ring signal on the DSS key and can be answered by the operator at any time even while the voice message is playing to the caller.
See Timing table Grade O for settings for this parameter.
SK-200 Lodging Package Installation & Programming Page 67
Item 07 - ACD-1 Segment 2 Recall Time:
This parameter sets the time an ACD-1 call which has been answered by the VSU company greeting message will stay on hold in the operator queue before the system will play the second part of the ACD-1 message to apologise for the continuing delay. The call back time for the second message starts at 30 seconds and increases in 15 second increments. The message will be played to the caller every time the recall time is reached until answered by the operator or the caller hangs up.
See Timing table Grade N for settings for this parameter.
Item 08 - ACD-1 Release Time:
This parameter sets the time at which the system will release the incoming caller during ACD-1 operation when it has not been answered by an operator. The system will play a warning message to the caller before releasing the call. If polarity reversal or Loop Disconnect is used for incoming call clear down then this parameter must be disabled.
TIMING TABLE
Grade 0
N
O
P
See Timing table Grade P for settings for this parameter
Dis
5
Dis
1
30
10
5
2
45
15
10
3
60
20
15
4
75
25
20
5
90
30
25
6
105
35
30
7
120
40
35
8
135
45
40
9
150
50
45 unit sec. sec.
Min.
Page 68
Program 05-10-IP : System Timing Parameters - 10
05-10-IP SYS PAR
IP = 01-08 d d d d d d d d
System Default.
Description:
This parameter allows the system to insert digits before the call forwarded station number when the call forward is received by the voice mail port if Standard Protocol is selected. If the station numbering is 2, 3 or
4 digits the system will insert additional digits if the Voice Mail requires more. The last digits of the voice mail box number will still have to be the same as the station numbering for correct recognition. The HOLD key can be used to insert a pause in the DTMF tone sending and will display as a (p). The DND key is no digits sent and is shown as (d).
Example:
The SK-200 is set to 2 digit numbering but the voice mail requires 4 digits. The voice mail also requires a pause between answering the call and the tones being sent. Set this parameter to the following
05-10-IP SYS PAR p 1 1 d d d d d
When the call forwarded station 11 is answered by the voice mail port after the pause time the digits 1111 will be sent to the port by the system. If station 11's voice mail box is 1111 then the mailbox number 1111 will be automatically opened by the tones.
There are 2 different Voice Mail Protocols available in the SK-200 series depending on the setting in Form
05-12-05. If this form is set to 0 then the Protocol will be the leading digits entered in this Mode plus the
Station Number of the forwarded station. If Form 05-12-05 is set to 1 then the Enhanced Protocol shown on the following page will be used.
Enhanced Protocol
Internal Calls
CFWD All Calls
CFWD Busy
CFWD No Answer
Direct Call to V-Mail Port
Digits
11-STB-STA
12-STB-STA
13-STB-STA
14-STA-STA
DISA and CO Calls
CFWD All Calls
CFWD Busy
CFWD No Answer
Recall to Voice Mail
Digits
21-STB-TRK
22-STB-TRK
23-STB-TRK
25-STB-TRK
Direct Call From Trunk 24-TRK-TRK This digit sequence is played only on cncoming calls when 05-12-05 is set at a value of 1 or 3.
STA = The originating station presented as 4 digits.
STB = The forwarding station presented as 4 digits.
TRK = the CO trunk presented as 4 digits.
In systems using 2 digit number plans, the STA and STB fields use leading digits. For example,
SK-200 Lodging Package Installation & Programming Page 69
extension 11 is presented as 0011, extension 12 is presented as 0012, etc.
In systems using 3 digit number plans, the STA and STB fields use leading digits. For example, extension 111 is presented as 0111, extension 112 is presented as 0112, etc.
Systems using 4 digit extension numbering will present all four digits for STA and STB.
TRK is provided as the two digit trunk number (01-40). The field is also filled with leading zeros, so trunk 01 is presented as 0001, trunk 08 is presented as 0008, etc.
Page 70
Program 05-11-IP : System Timing Parameters - 11
05-11-IP SYS PAR
IP = 01-08
1 0 0 0 0 0 0 0
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display D ata
0-1
0-1
0-1
0-1
0-3
0-9
0-9
0-8
Programming Data Description
Resume Key Phone Volume On Plug In
DISA Password - 1/(24 or 50) Sets
Select Music On Hold Or Ring Back Tone
DISA Answer Method - VSU Busy
DISA Special Function Access
DISA Re-check Times To Busy Console
Door Phone Ringing Time
DISA Single Digit Dialing
Timing
Grade Default
1=Disable
0=1
0=RBT
0=Yes
0=All
0=2 Times
0=5 Sec.
0=Disable
Description:
Item 01 - Resume KeyPhone Volume Settings On Plug In:
In default when the system is turned on after being in service or the KeyPhone has been unplugged, the
Key phones will reload the volume settings the user has programmed for Ring volume, Speaker volume and Handset volume (on handsets with the new processor it will also reload the Ring frequency). If this parameter is disabled then the default settings will be used instead.
0 = Enable 1 = Disable
Item 02 - Number of DISA Passwords:
This parameter when enabled will increase the number of DISA passwords from 1 to 50 (SK-200). At the default setting of 0 the DISA password will be set in form 13-02. If the parameter is set to 1, 50 passwords are available and they will be the same as the forced account codes numbers (49 to 99). Forced account codes are set in Form 17-(00-99).
0 = 1 password 1 = 50 Passwords
Item 03 - Select Music on Hold or Ring Back Tone:
This parameter selects what the incoming caller will hear during Ring Transfer and Hold Recall conditions.
The feature is designed specifically for North America to prevent the caller incorrectly recognising the SK-
200's International Ring Back Tone as a disconnect or engaged signal and hanging up even though their call is still in progress.
SK-200 Lodging Package Installation & Programming Page 71
0 = Ring Back Tone 1 = Music On Hold
Item 04 - DISA Call Processing Method When The VSU is busy or not Installed:
0 = The DISA caller will hear system dial tone after the system answers the incoming call.
When the VSU is busy, the DISA call will not be answered by the system unless an internal party
1 = answers this DISA call or the VSU is available for service again. During VSU busy, the system will ring the stations assigned in Programming Form 01 and 02.
Item 05 - DISA Special Function Access:
This parameter sets which of the system functions are able to be accessed by DISA callers.
0
1
=
=
Allow users to access the DISA special functions by pressing [8],[9],[*],[#].
Allow users to access the DISA special functions by pressing [*],[#].
2
3
=
=
Disallow users to access the DISA special functions by pressing [8],[9].
Allow users to access the DISA special functions by pressing [8],[9].
Disallow users to access the DISA special functions by pressing [*],[#].
Disallow users to access the DISA special functions by pressing [8],[9],[*],[#].
Item 06 - DISA Re-check Times To Station/Console:
This function sets the number of times that an unsuccessful DISA call will attempt to retry a station and or transfer to a console after the ringing time set in Form 05-08-06 if the Voice Sectioning function is activated and depending on the setting for individual stations in Form 46-st-04. If polarity reversal is available set this parameter to 9 and the call will continue to retry until the caller hangs up.
0 = 2 Times 1 = 3 Times 2 = 4 Times 3 = 5 Times
5 = 7 times 6 = 8 Times 7 = 9 Times 8 = 10 times
4 = 6 Times
9 = Unlimited
Item 07 - Door Phone Ringing Time:
This parameter sets the time that Door Phone ring assigned stations will ring for when the Door Phone button is pressed.
0 = 5 Seconds
5 = 30 Seconds
1 = 10 Seconds
6 = 35 Seconds
2 = 15 Seconds
7 = 40 Seconds
3 = 20 Seconds
8 = 45 Seconds
4 = 25 Seconds
9 = 50 Seconds
Item 08 - DISA Single Digit Dialing:
This feature allows a DISA caller to dial stations by 1 digit (1-5) using the settings in Form 10-gp-IP to set which station will be dialled by each digit.
0 = Disable SDD 1 = Dial Station in
Group 1
2 = Dial Station in
Group 2
3 = Dial Station in
Group 3
4 = Dial Station in
Group 4
Page 72
5 = Dial Station in
Group 5
6 = Dial Station in
Group 6
7 = Dial Station in
Group 7
8 = Dial Station in
Group 8
SK-200 Lodging Package Installation & Programming Page 73
Program 05-12-IP : System Timing Parameters - 12
05-12-IP SYS PAR
0 0 0 2 0 0 1 0
IP = 01-08
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0
0
0-1
0-9
0-7
0-1
0-1
0-9
Programming Data Description
Reserved
Reserved
Exclusive Hold
Door Unlock Relay Activation Time
Voice Mail Call Forward Protocol Type / Mute Digits
Linear/Circular Trunk group access
LED indication of Check in / Check out on DSS console
Fire Alarm Ringing Time
Default
0
0
0 = Enable
2 = 3 seconds
0 = Standard
0=Linear
1=Enable
0=1 Sec.
Description:
Item 01 - Reserved:
Item 02 - Reserved:
Item 03 - Exclusive Hold Capability:
If this parameter is enabled all stations can use the Exclusive Hold Function. If the parameter is disabled no stations will be able to place calls on Exclusive hold.
0 = Enabled 1 = Disabled
Item 04 - Door Unlock Relay Activation Time:
This parameter sets the time that the door unlock relay will remain activated after the Door Unlock function is activated by the user. The Door unlock relay is programmed in Form 06.
0 = 1 Second
5 = 6 Seconds
1 = 2 Seconds
6 = 7 Seconds
2 = 3 Seconds
7 = 8 Seconds
3 = 4 Seconds
8 = 9 Seconds
4 = 5 Seconds
9 = 10 Secs.
Page 74
Item 05 - Voice Mail Call Forward Protocol Selection and Muting Leading Digits
This parameter selects between Standard Voice Mail Call Forward Protocol and the Enhanced Protocol.
For a full description of Voice Mail Protocol see Form 05-10.It will also set the muting of the leading digits
Setting Value
VMS Leading Digit Type
Mute Leading Digit
Leading Digit for Auto
Attendant (VMS)
0
Short
No
No
1
Long
No
Yes
2
Short
Yes
No
3
Long
Yes
Yes
4
Short
No
No
5
Long
No
No
6
Short
Yes
Yes
7
Long
Yes
No
“Short” type: Use the Leading Digit(s) programmed in program 05-10 plus Station number.
“Long” type: Use 10 Digit protocol as explained below.
“Mute Leading Digit”: The caller will not hear the DTMF signal during the transmission of leading digits.
The system will use the last intercom link for this feature.
“Long” Enhanced Protocol
Internal Calls
CFWD All Calls
CFWD Busy
CFWD No Answer
Direct Call to V-Mail Port
Digits
11-STB-STA
12-STB-STA
13-STB-STA
14-STA-STA
DISA and CO Calls
CFWD All Calls
CFWD Busy
CFWD No Answer
Recall to Voice Mail
Digits
21-STB-TRK
22-STB-TRK
23-STB-TRK
25-STB-TRK
Direct Call From Trunk 24-TRK-TRK This digit sequence is played only on cncoming calls when 05-12-05 is set at a value of 1 or 3.
STA = The originating station presented as 4 digits.
STB = The forwarding station presented as 4 digits.
TRK = the CO trunk presented as 4 digits.
In systems using 2 digit number plans, the STA and STB fields use leading digits. For example, extension 11 is presented as 0011, extension 12 is presented as 0012, etc.
In systems using 3 digit number plans, the STA and STB fields use leading digits. For example, extension 111 is presented as 0111, extension 112 is presented as 0112, etc.
Systems using 4 digit extension numbering will present all four digits for STA and STB.
TRK is provided as the two digit trunk number (01-40). The field is also filled with leading zeros, so trunk 01 is presented as 0001, trunk 08 is presented as 0008, etc.
SK-200 Lodging Package Installation & Programming Page 75
Item 06 - Linear/Circular Trunk Group Access:
If this parameter is set to 0 then line selection will be the first available trunk in the users dial (9-0) group. If the parameter is set to 1 then the lines will be selected in a Circular fashion till all lines have been used and then the selection will start again. Do NOT use Circular unless there is a very good reason as call collision will result.
0 = Linear 1 = Circular
Item 07 - LED indication of Check in/ Check out:
This parameter disables or enables the LED indication for Check in/Check out and Clean room status for the DSS consoles and DSS Keys.
0 = Disable 1= Enable
The LED indications are as follows:
Red / slow flash:
When Reception checks out an extension, the extension LED will slow flash red.
Green:
When the checked out extension’s room has been cleaned by the cleaner, they can dial
[776] from the phone and hang up. The LED for that extension will go Green. This means
Red:
Off:
the room is clean and ready for a new guest.
The room is checked in and the phone is in use
The room is checked in and idle.
Item 08 - Fire Alarm Ringing Time:
This parameter sets the time the Fire Alarm will ring for when activated.
0 = 1 minute
5 = 6 minutes
1 = 2 minutes
6 = 7 minutes
2 = 3 minutes
7 = 8 minutes
3 = 4 minutes
8 = 9 minutes
4= 5 minutes
9 = 10 minutes
Page 76
Program 05-13-IP : System Timing Parameters - 13
05-13-IP SYS PAR
IP = 01-08
0 0 0 0 0 0 0 0
System Default.
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-1
0
0
0-9,d
0
0
0
0
Programming Data Description
PMS (Fidelio) Enable
Reserved
Call Cut Off Timer - No Pulse Reversal Received
Door Phone Ring Frequency (Key Phone Only)
Reserved
Reserved
Reserved
Reserved
Default
0 = No
0
0 = No
0
0
0
0
0
Description:
Item 01 - PMS (Fidelio) Enable:
This parameter when enabled will allow the SK-200 to interface with the Micros Fidelio Property
Management System in Hotels/Motels. Enabling this parameter will completely change the SMDR output and will allow the Front Office computer to control Check In/Out, Guest names, Room Change, Wake Up calls, Message Waiting, Clean Room status and DND status. See the Hotel Motel manual for full details.
0 = Disable 1= Enable
Item 02 - Reserved:
Item 03 - Call Cut Off Timer - No Polarity Reversal Received:
In Program 29-tk-06 each trunk can be set to cut of an outgoing call if the Polarity Reversal signal is not received within the time set here.
0 = Disable
5 = 90 Seconds
1 = 30 Seconds
6 = 105 Seconds
2 = 45 Seconds
7 = 120 Seconds
3 = 60 Seconds
8 = 135 Seconds
4 = 75 Seconds
9 = 150 Seconds
Item 04 - Door phone Ring Frequency for Key Phones:
This parameter can assign different ringing frequencies or ring types for Door phone calls.
0 = As the setting of key phone’s Ring. 1~8 = Use the ringing frequency 1~8 of AK key phones as
SK-200 Lodging Package Installation & Programming Page 77
9 = Use “Tone” as the Door phone’s ring. the Door phone’s ring. d = Use “Background Music” as the Door phone ring
Program 05-14-IP : System Timing Parameters - 14
05-14-IP SYS PAR
0 0 0 0 0 0 0 0
IP = 01-08
System Default.
All Items currently Reserved and Unused:
Page 78
Program 06-IP : Relay Assignment
06-gp-IP Relay
00 00 00
gp = 01-04. IP = 01-03
System Default.
ItemPoint er
01
02
03
Display Data
00-18
00-18
00-18
Programming Data Description
Relay # 1 of B4-IPU
Relay # 2 of B4-IPU
Relay # 3 of B4-IPU
Description:
On the SK-200 each relay card has 3 Dry Contact Relays and each IPU can support 1 relay card making a total of 12 relays in a 4 cabinet system.
No voltage is provided by the system, the installer will have to provide their own source to suit the application. Do not use the relays to switch 240 V. They are only designed for low voltage control circuits.
All Relays are Normally Open contacts and will close on activation of the function for which they have been programmed.
Assign the required Relays one of the following functions.
Set data
00
Function
No Operation
01
02
03
04
05
Music On Hold
Door 1 open
Door 2 open
Trunk loud bell
Station loud bell
Set data
06
07
08
09
10
11-18
Function
System Alarm
Remote Relay Control
Trunk loud bell - Continue on
Station loud bell - Continue on
All zone page
External Zone 1-8 page
An outside caller using DISA, on receiving dial tone, can key in the relay password to
turn relays on/off, a tone after keying in the password means the relay is activated.
Relay controlling password:
841 ---> to control the 1st relay on.
842 ---> to control the 2nd relay on.
.................
849 ---> to control the 9th relay on.
851 ---> to control the 1st relay off.
852 ---> to control the 2nd relay off.
.....................
859 ---> to control the 9th relay off.
SK-200 Lodging Package Installation & Programming Page 79
Program 07-gp-IP : Flexible Key Group Assignment
07-gp-IP KEY GRP
gp = 01-08 IP = 01-25 (DSS Key Number)
TK: nn
TK number for the key
07-gp-IP KEY GRP
xxx
07-gp-IP KEY GRP
FN: ff gp=01-08 IP=01-25 (DSS Key Number)
Station number for the key
gp=01-08 IP=01-25 (DSS Key Number)
Function number for the key
General:
This program assigns 8 groups of Flexible key plans for Key phones.
Each KeyPhone can be assigned to use two groups (Form 42-st-(02 & 03).
Description:
Each key can be assigned as either a Trunk, a Station or a Function.
To change the assignment from TK to Station or to Function or vice versa, press the [AT/MIC] key before setting.
nn = 01-08 - Trunk Key (1 to 08)
xxx = 100-699 - Station Key ( 3 digits )
ff = 00-64 - Function Key (0 to 64)
xx= 10-69 - Station Key (2 digits)
xxxx= 1000-6999 - Station Key ( 4 digits )
Default Key Telephone Templates
Group 1
VOL
-
VOL+ FWD DND PROG
ST15
ST11
TK05
TK01
ST16
ST12
TK06
TK02
ST17
ST13
TK07
TK03
ST18
ST14
TK08
TK04
SAVE
MSG/PT
SPD
MIC/AT
Page 80
Group 3 (Default for SK1-2X)
PROG SAVE DND SPD
ST15
ST11
TK05
TK01
ST16
ST12
TK06
TK02
ST17
ST13
TK07
TK03
ST18
ST14
TK08
TK04
FWD
MW/PT
AT/MIC
VOL +
VOL -
Group 3 (Default for SK1-33 Not available in U.S.)
PROG
TK01
SAVE
TK02
DND
TK03
SPD
TK04
VOL+
VOL -
16
17
11
12
13
14
15
Key Telephone Function Codes
ff Code
00
Function
No Operation
06
07
08
09
10
01
02
03
04
05
Program
Do Not Disturb/Conference
Message Waiting/Pulse-Tone
Microphone/AUTO answer
Speed Dial
SAVE
Volume UP
Volume Down
Forced Account Code
Voice Set up
User Speed Dial Set up
Console User Speed Dial Set up
Console System Speed Dial Set up
Security Code Set up
Help List
Temporary Security Code
Check In
SK-200 Lodging Package Installation & Programming
31
32
33
34
35
26
27
28
29
30
36
37
ff Code
20
21
22
23
24
25
Function
All Paging (Internal)
All Paging (External)
All Paging (Internal/External)
Zone Paging (Internal)
Zone Paging (Internal) 1
Zone Paging (Internal) 2
Zone Paging (Internal) 3
Zone Paging (Internal) 4
Zone Paging (Internal) 5
Zone Paging (Internal) 6
Zone Paging (Internal) 7
Zone Paging (Internal) 8
CLI Status
Zone Paging (External) 1
Zone Paging (External ) 2
Pickup Own Group
Pickup All Groups
Pickup Group
Page 81
50
51
52
45
46
47
48
49
40
41
42
43
44
18
19
ff Code
Check Out
Charge Inquire
Function
Pickup Group 3
Pickup Group 4
Pickup Group 5
Pickup Group 6
Pickup Group 7
Pickup Group 8
Toll Password
Alarm Assign
User Alarm
Console- Set up Alarm
Console- Set up System Time
Message Select
Day / Night
64
65
58
59
60
62
63
53
54
55
56
57
38
39
ff Code
Pickup Group 1
Pickup Group 2
Function
Forward All
Forward Busy
Forward No Answer
Meet me Page
Shift Key
Meter Rate Setting
Hotel/Motel Function
Call Park
Directory key (for name search)
ISDN Pre-Dial Key
Log in/Log out of Queue
Wake Up
Page 82
Program 08-01-IP : Flexible DSS Key-Group Assignment
08-gp-IP KEY GRP
gp = 01(-08) IP = 01-60 (DSS Key Number)
TK: nn
TK number for the key
08-gp-IP KEY GRP
xxx
gp = 01(-08) IP = 01-60 (DSS Key Number)
Station number for the key
08-gp-IP KEY GRP
FN: ff gp = 01-(08) IP = 01-60 (DSS Key Number)
Function number for the key
General:
This program sets 8 groups of programmable DSS keys for the DSS Console.
There are eight groups for the SK-200.
Description:
Each key can be assigned as either a Trunk, a Station or a Function.
To change the assignment from TK to Station to Function or vice versa, press the [AT/MIC] key before setting.
nn= 01-40 - Trunk Key (1 to 40)
xxx= 100-699 - Station Key ( 3 digits )
ff= 00-64- Function Key (0 to 58)
xx= 10-69 - Station Key ( 2 digits )
xxxx= 1000-6999 - Station Key ( 4 digits )
For function key setting use the list provided in Form 07.
SK-200 Lodging Package Installation & Programming Page 83
Program 09-nnn-DP : System Speed Dial
09-nnn-DP TK:tt
nnn = 100-599(999) DP = 01-30 nnnnnnnnnnnnnnnn
tt = 01-08
Telephone number.
General:
This program permits the assignment of up to 500(900) sets of system speed dialing codes.
Description: nnn
DP tt
=
=
=
100-999
01-30
01-40
=
=
=
Speed dial code, up to 900 sets in total.
Digit Pointer for telephone number. 30 digits per speed dial code
Pre-assigned CO line number
Pre-Assigned CO Line:
Press the [MIC] key to change or clear the Pre-assigned CO line number. This CO line is the dedicated outgoing line for the speed dial code. If the user presses a speed dial code without selecting a CO line first, the system will select this CO Line automatically. If no CO line is assigned, the system will select an available CO line according to the assigned Dial 9 group (Program 41-nnnn-04). A line may also be selected directly by the user.
Telephone Number:
30 digits maximum may be entered in each memory.
In addition to the digits 1 to 0, *, # the following can also be stored: Pause, Flash, Pulse to DTMF. Each function occupies one digit.
"Pause" is represented by the [HOLD] key.
"Flash" is represented by the [FL] key.
-- p
-- F
"Pulse to DTMF" is represented by the [PT] key. -- T
I) Pause : During dial procedures, the dialing will wait for a programmable period
(Refer Program 05-01-06). ii) Flash : This will make a loop disconnection of a pre-assigned duration.
(Refer program form 05-02-05). iii) Pulse to DTMF : If the dial signal is "pulse", it will change to "DTMF".
Note: Pressing [DND] will erase the digit which the cursor is on.
Pressing [REDIAL] will erase all the assigned digits.
Page 84
Program 10-gp-IP: Intercom or DISA Single Digit Assignment
10-gp-IP S.D.I. gp = 01-08, IP = 01-05 (digit 1 to 5)
000 000 000 000 000
Station number for digit 1 to 5
General:
This program permits the stations in one or more station groups to call a specific station by dialing one digit only. This feature is for the Hotel/Motel environment only. (Refer to programming form 05-04-07 to enable single digit dialing). The settings in this Form are also used by DISA Single Digit Dialing (see Form 05-11-08 to enable).
Description:
Single Digit Intercom.
When single digit dialing is enabled then the room to room call prefix digit (6) must be dialed to call another room.
If a particular group has no entries programmed, the stations in the same number station group will not have single digit dialing and will not have to use the room to room prefix.
Single Digit DISA.
When single digit dialing is enabled and a group (1-8) selected in Form 05-11-08 then DISA callers will be able to dial the stations in the group selected by dialing the digits 1 to 5. The digit 1 will call the first station in the group, 2 will dial the second station in the group and so on up to digit 5. The caller can also dial 6 and then dial a full extension number to call other extensions or dial (0 or 9) to call the operator.
If a position is left programmed to 0 then station numbers starting with the digit which corresponds to this position can be dialled in full.
Example
10-gp-IP S.D.I.
111 153 222 000 550
In the above example an incoming DISA caller who dials 1 will call station 111, dialing 2 will call station 153,
3 will call Station 222. Dialing 4 will allow the caller to dial the full extension number of any extension which starts with 4, eg 444. 550 has been assigned as a Hunt Group Pilot number so a DISA caller dialing 5 will call the Station hunting group which has 550 as it's pilot Number. Pilot numbers are set in Form 67 and
Hunt groups are programmed in Form 68 and 69.
SK-200 Lodging Package Installation & Programming Page 85
Program 11-IP : Date and Time Setting
11-IP Date/Time
08 27 87 18 16 4
IP = 01-06
Setting Data
ItemPoint er
01
02
03
04
05
06
Display Data
01-12
01-31
00-99
00-23
00-59
1-7
Programming Data Description
Month......................
Day........................
Year.......................
Hour.......................
Minute.....................
Week day (Monday = 1, Tuesday = 2)..
General:
This program permits the setting of system Date & Time. Please note that all TransTel products are Year
2000 compliant including the recognition of the year 2000 as a leap year
Description:
The Date & Time will be held during a power failure on the SK-200, there is no need to reset the Time after power is restored.
Page 86
Program 12-nn : System Alarm Clock
12-nn Alarm hh mm dd
nn = Alarm schedule (01-10)
Setting Time
ItemPoint er hh (01) mm (02) dd (03)
Display Data
00-23
00-59
00-99
Programming Data
Hour.
Minute.
Duration.
Description
General:
This program permits the assignment of 10 time schedules for alarm clock purposes.
Description:
When the assigned time is reached, Background music will be broadcast over all Key telephones which are idle. The time duration for alarm clock music is programmable (00 to 99 minutes).
SK-200 Lodging Package Installation & Programming Page 87
Program 13-nn : Password
13-nn Password d d d d d d d d
nn = Password Assigned (01-09)
Setting password
General:
This program permits the assignment of 9 different passwords in the system.
Description:
The password length is from 1 to 8 digits. All unused digit positions must have d entered in them.
Password No. 1 = Programming Password. System Default is None.
Password No. 2 = DISA Password. System Default is 3472
Password No. 3 = Toll Free. System Default is 8655
Password No. 4 = DISA Monitor Password.
Password No. 5 = Password for remote access to VSU Default is 97d3dddd
Password No. 6 = DISA Remote Paging Password.
Password Nos. 7 to 9 = Future.
Page 88
Program 14-01-IP: SMDR Specifications
14-01-IP S.M.D.R.
IP = 01-08
0 0 0 0 0 21 0 0
System Default
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-9
0-1
0-1
0-1
0-1
00-99
0-4
0-8
Programming Data Description
Call Duration Start Time
Record Incoming Call
Record Local Call
Record Incoming Call No Answer
Print out the Title
Number of records between titles
SMDR Output Port - SK-200
Polarity Reversal/Mini Call Acc/CLI.
Default
0=00 Secs.
0=Record
0=Record
0=Record
0=Yes
21=21
0=MPU
0=No
General:
This program assigns SMDR parameters.
Description:
Item 01 - Call duration start time:
This parameter assigns the start time for the Call duration timer.
0 = 00 seconds
5 = 25 seconds
1 = 05 seconds
6 = 30 seconds
2 = 10 seconds
7 = 35 seconds
Item 02 - Record Incoming Calls:
This parameter decides whether incoming calls will be recorded.
0 = Record
3 = 15 seconds
8 = 40 seconds
1 = Do not Record
Item 03 - Record Local Calls:
The system decides which are local calls by the toll access code set in Form 05-03-05.
Item 04 - Record Incoming Calls No Answer:
This parameter decides whether unanswered incoming calls will be recorded.
SK-200 Lodging Package Installation & Programming
4 = 20 seconds
9 = 45 seconds
Page 89
0 = Record 1 = Do not Record
Item 05 - Print the Header:
This parameter decides whether the system will output the description of each column.
0 = Print the Header 1 = Do not print the Header
Item 06 - Number of records between the Header:
This parameter permits the assignment of the number of records between each Header. If the Number =
00, The whole SMDR feature will be disabled.
Item 07 - SMDR Output Port (SK-200):
This parameter sets which RS232 port on the SK-200 will carry the SMDR information.
0 = MPU 1 = IPU1 2 = IPU2 3 = IPU3 4 = IPU4
Item 08 - Polarity Reversal and Mini Accounting Feature:
If reversal is disabled, the system will start the call timer after accessing a CO line.
If reversal is enabled, the system will start the call timer after the called party answers.
0
1
=
=
Not Detect P.R. / Normal SMDR format output
Detect P.R. / Normal SMDR format output
2
3
4
=
=
=
Not Detect P.R. / Simple SMDR format output
Detect P.R. / Simple SMDR format output
Not Detect P.R. / Enable Mini-Accounting Feature
5 =
=
=
Detect P.R. / Enable Mini-Accounting Feature
Not Detect P.R. / Enable intercom SMDR / Normal SMDR format output (899 records)
Detect P.R. / Enable intercom SMDR / Normal SMDR format output (1400 records)
* If the Mini-Accounting Feature has been enabled, the system will not record the call without any meter pulses being received.
* When the Mini Call Accounting feature is enabled it is necessary to set Administration phones to not record calls against them in Form 45-st-08. This will prevent the system memory from being used to record calls unnecessarily. If administration phones are allowed to record their calls and are not checked out regularly then they will fill the system memory and prevent other calls being recorded. The SK-200 can store 1400 records.
Page 90
SMDR OUTPUT DATA FORMAT - OLD
ST. TK S TELEPHONE NUMBER Account MM/DD START DURATION RING UNIT
112 01 001188629645752 12345678 10/02 08:35 00:02'35" 00012
115 02 Incoming 87654321 10/02 08:45 00:10'20" 00'10"
000 03 Incoming no answer 10/02 12:00 00'35"
112 04 001188629645752 FAC:01 10/02 12:10 00:02'00" 00023
112 03 X FAC or PSW error 10/02 12:30
112 05 X 001 10/02 12:35 00:00'05"
121 01 # 0294150100 10/02 14:15 00:00'55" 00001
117 01 * 0294150100 10/02 14:15 00:03'10" 00004
D3 05 0418220212 10/02 21:01 00:02'30" 00003
D-03 D << D I S A OFF >> 10/02 21:00 00:02'40"
TITLE DESCRIPTION:
ST = Station No.
TK = Trunk No.
S = Status
: 11 to 6999, D = DISA
: 01 to 08,
: # = Hold, * = Answered the hold, X = Cut off by toll restrictions.
Telephone Number
Account
MM/DD
Begin_Time hh:mm
Duration_Tm hh:mm:ss
Ring_Tm mm:ss
Unit 00000
: First 24 digits
: 8 digits in total
: Month/Day
: The start time of accessing the trunk line.
: Time duration of the call.
: Incoming ring time.
: Meter Pulse Count
CASE EXPLANATION:
CASE 1: October 2, 08:35 A.M., Station 112 made a call (telephone No. is 00116495256611) through line 1. The call lasted 2 minutes and 35 seconds, Account code No. 12345678 was entered for the call and 12 meter pulses were recorded.
CASE 2: October 2, 08:45 A.M., An incoming call on line 2, rang for 10 seconds, station 115 answered the call and stored an Account No. 87654321.
CASE 3: October 2, 12:00 P.M., An incoming call through line 3, rang for 35 seconds, no one answered and the call was abandoned.
CASE 4: October 2, 12:10 P.M., Station 112 made a Long Distance call through line 4 by Forced Account Code 1 and 23 meter pulses were recorded.
CASE 5: October 2, 12:30 P.M., Station 112 made a call by Forced Account Code but was denied because of a wrong code.
CASE 6: October 2, 12:35 P.M., Station 116 made a call which was restricted.
CASE 7: Line 1 was used by station 121 for 55 seconds then put on hold. One meter pulse was recorded against this station for it's section of the call.
CASE 8: The held line 1 was answered by station 117 and he occupied the line for 3 minutes and 10 seconds. Four meter pulses were recorded against this station for it's section of the call.
CASE 9: Incoming Line 3, using the DISA function, made an outside call 018220212 on line 5. The Duration time is for line 5. 3 meter pulses were recorded for this call.
CASE 10: DISA is completed. The Duration time is for line 3.
SK-200 Lodging Package Installation & Programming Page 91
SMDR OUTPUT DATA FORMAT - NEW With CLI Output
ST. TK S TELEPHONE NUMBER Account MM/DD START DURATION RING UNIT
112 01 001188629645752 12345678 10/02 08:35 00:02'35" 00012
112 02 DDI Num: 94150112 10/02 08:45 00:10'20" 00'10"
03 CLI NoAns:294176288 10/02 12:00 00:00'00" 00'35"
111 05 CLI Num :294150100*11 10/02 12:35 00:00'05" 00'05"
05 DDI NoAns:94150112 10/02 12:37 00:00'00" 00'27"
Case 1: Outgoing call. All information remains as before.
Case 2: Incoming call on an ISDN system. The number displayed is the Indial number dialled by the calling party. The system can be programmed on a station by station basis to select whether calls to that station will display the Indial number dialled or the CLI information of the incoming caller
Case 3: An incoming call rang for 35 seconds and no one answered. The CLI number of the calling station is displayed.
Case 4: An incoming call on line 5 (ISDN) was answered by station 111. The SMDR displayed the CLI number
(294150100) of the calling party and the extension number (112) of the calling party. The extension number shown is what the system will receive if the call is from another SK-200 with ISDN. The format may be different or non existent from other telephone systems or on PSTN lines. The system can be programmed on a station by station basis to select whether calls to that station will display the Indial number dialled or the CLI information of the incoming caller. The number 94150100 is the pilot number of the Indial group.
Case 5: An incoming call rang for 27 seconds and no one answered. The Indial number the calling station dialed is displayed.
Page 92
Program 17-nn : Forced Account Code
17-nn FCAC CODE
_ _ _ _ _ _ _ _ _
nn = Forced Account Code (01-99)
Forced account code (8 digits max.)
General:
This program creates 99 (SK-200) Forced Account codes.
Description:
The forced account code will temporarily override a station's toll restrictions.
99 (SK-200) codes of up to 8 digits maximum are allowed. If the system is fitted with a call accounting output the entry for a call made using a forced account code will display the code used in the account code column. The actual numbers of the code will not be displayed for security reasons, the reading will show FAC:XX. XX is the forced account code number
01 to 99.
The Forced Account Code will not be displayed on the screen of Executive phones when it is entered.
Digit "_" is keyed in by [FL] button and means " No digit ".
Clear all digits by pressing [TRF/FL] to insert a line in place of the original entry.
Do not use Redial to clear forced account code entries as this will insert "don't cares" which will allow any digit as a forced account code.
The Forced Account Codes may also be used as DISA passwords to allow call accounting to show which user was making an external call using DISA from outside the system. In the B1-408 & BX8, Forced Account Codes 24 to 48 can be used for this purpose and in the SK-200, Forced Account Codes 49 to 99 can be used. This feature will need to be enabled in Form 05-11-02.
SK-200 Lodging Package Installation & Programming Page 93
Program 18-nn-TK : Assign Toll Plans To Trunk Lines
18-nn-tk Toll
nn = Toll plan number (00-09), tk = (01-08)(01-
0 0 0 0 0 0 0 0
40)
Toll class for each trunk (class 0-9)
General:
This Form assigns Toll Plans to trunk lines. The Toll plans are to be written in Forms 51 to 59 and 61 to 66.
Description:
10 toll plans can be used.
Each Toll Plan assigns each trunk line a Toll Class. It is possible to allow a toll class to have different restriction level on a line by line basis.
Example 1: Form 18-00 is set to 0000dddd. Any station in the system which is set to toll class 0 will be unrestricted on lines 1 to 4 but will be unable to dial out on lines 5 to 8.
Example 2: Form 18-01 is set to 111100dd. Any station in the system which is set to toll class 1 will be restricted by toll class 1 on lines 1 to 4, will be unrestricted on lines 5 and 6 but will be unable to dial out on lines 7 and 8.
To assign toll plans to stations, see Program 41-st-05, 41-st-06.
6
7
8
9
Toll Classes:
Class
0
1
Function
Unrestricted
Use Form 51 for the Unrestricted numbers. Use Form 61 for the Restricted numbers
2
Use Form 52 for the Unrestricted numbers. Use Form 62 for the Restricted numbers
3
4
Use Form 53 for the Unrestricted numbers. Use Form 63 for the Restricted numbers
Use Form 54 for the Unrestricted numbers. Use Form 64 for the Restricted numbers
5
Use Form 55 for the Unrestricted numbers. Use Form 65 for the Restricted numbers
Use Form 56 for the Unrestricted numbers. Use Form 66 for the Restricted numbers
Use Form 57 for the Unrestricted numbers.
Use Form 58 for the Unrestricted numbers.
Use Form 59 for the Unrestricted numbers.
*
d
Use Form 51-56 for unrestricted numbers. Use Form 61-66 for all restricted numbers
Cannot access the trunk line.
Prog. Form
Default
Form 51,61
Form 52,62
Form 53,63
Form 54,64
Form 55,65
Form 56,66
Form 57
Form 58
Form 59
Page 94
Program 19-IP : Voice Service (VPC) Assignment
19-VS-IP VAC ASN
VS = VSU Module Number (01-40)
00 00 00 00 00
IP = 01-08
Function of Voice segment on VPC
General:
This program assigns voice services to segments of the VPC. On the SK-200 the channel numbers are X901 to
X940. X is the SLT programming digit set in Form 05-08-05 (normally 7).
The station numbers on the first VSU card are X901-X904.
The station numbers on the second VSU card are X905-X908.
The station numbers on the last VSU card are X937-X940.
Description:
IP = 01 Voice segment number 01. IP = 05 Voice segment number 05.
IP = 02 Voice segment number 02. IP = 06
IP = 03 Voice segment number 03. IP = 07
IP = 04 Voice segment number 04. IP = 08
IP = 09 Assign Channel to VSU Group (SK-200)
Voice segment number 06.
Voice segment number 07.
Voice segment number 08.
IP = 09 0 = 60 second voice chip
Eight voice segments are valid for the VAC card and each can be assigned one of 18 functions.
Set data Function
00 No-Operation
01 DISA: Company greeting message (on answer)
02 DISA: Message to tell the outside party that the called extension is Busy.
03 DISA: Message to tell the outside party that the called extension is No Answer.
04 DISA: Message to tell the outside party that the extension number is Not-Valid.
05 DISA: Message to tell the outside party the Console is busy, please wait.
06 DISA: Message to tell the outside party the DISA Time duration has expired.
07 DISA: Message to tell the outside party that the Console is still busy, this line will be disconnected, please call again later.
08 DISA: Night greeting message (on answer).
09 ECF: Message to advise caller that the call is being external call forwarded.
10 ACD: Message to tell caller that the console is busy, please wait
11 ACD: Message to tell caller that the console is still busy, please wait.
12 ACD: Message to tell caller that the console is still busy, call will be disconnected, please call back later.
13 * Reserved for future use.
14 Morning Call -- Wake up Message.
15 Call Waiting Message.(Refer to programming form 05-04-08.)
16
17
* Reserved for future use.
* Reserved for future use.
18 Company Greeting message instead of Music On Hold (BX8).
SK-200 Lodging Package Installation & Programming Page 95
09. When VSU grouping is enabled for the SK-200 in form 05-06 then this parameter assigns the channel to the group (1 to 8) with which it will work.
During DISA operation if there is no VSU channel allocated to DISA Night Answer (type 08) then DISA calls will be answered by the DISA Day message in both Day and Night form.
RECORDING VOICE MESSAGES
VOICE MESSAGES MUST BE RECORDED FROM AN OPERATOR CONSOLE ONLY.
There is only one channel available in the BX8 and this is accessed by dialing 86 from the console. The SK-200 has multiple channels which will be numbered 79 (01-40). Each channel can be divided into 1 to 8 segments depending on requirements. Channel numbers indicated on the sample screens in Bold only refer to the SK-200.
VOICE PORT 7901 (1)
0=REC 7=PLAY
Dial 0 and after the tone has stopped, record the company greeting message,
VOICE PORT 7901
RECORDING.............
When completed Dial 1 and the screen display will be,
VOICE PORT 7901 (2)
0=REC 7=PLAY
The 2 in brackets indicate that the second message segment is ready to record. Dial 0 and record the message to apologise for the continuing delay,
VOICE PORT 7902
RECORDING.............
When the message is recorded dial 1. Continue using the same procedure until all the required segments are recorded and then hang up.
Remote VSU Recording Feature
This allows the user to remotely record/play/copy VSU messages. To use this feature it will be necessary to enable
DISA and install the EMC card on the B4-MPU.
The method of operation is:
(1) Enable DISA feature by setting form 35-tk-04.
(2) Dial [#][7] during DISA to access the remote access code.
(3) Dial [Password] that has been assigned in form 13-05.
(4) Dial 7901 ~ 7940 to access different VSU channels.
(5) Dial [0] for remote recording
Page 96
Dial [7] for remote playing
Dial [1] to change to the next recording segment
Dial [3] to copy the first channel of the VSU card into the other three channels.
Dial [#] to go back to the first voice segment of VSU channel.
(6) Dial [*] to end this feature.
Programming Form 13-05 - Password for Remote Accessing VSU Card. The default is 9703.
Programming Form 25 - press [8] to clear all related timers of VSU remote accessing.
Only one DISA line can remotely access the VSU at a time.
The VSU cannot answer DISA lines during remote access of the VSU.
The remote access feature will always access the first voice segment of the channel (7901~7940).
SK-200 Lodging Package Installation & Programming Page 97
Program 20-nn : Define Day-Time Schedule
20-nn Day Time
nn = Day schedule pointer (00-06) hh mm HH MM
Setting data
General:
This program assigns day time from Sunday to Saturday for automatic night switching.
Description:
The system is capable of switching automatically between day and night settings using the time parameters set in this Form. To change from manual to automatic night switching the console presses [PRG] /[TRF] / *. Pressing * toggles between the 2 forms.
If a Function key has been set to function 52 then pressing this key will change from Day to night form by one touch but will not change between Automatic and Manual switching.
00 = Sunday
01 = Monday
02 = Tuesday
03 = Wednesday
04 = Thursday
05 = Friday
06 = Saturday
HH, hh = Hour MM,mm = Minute
Day time is from hh:mm to HH:MM.
Page 98
Program 25 : Reset Data to System Default
25 - Reset Data
0 - 9 Default
General:
This program resets all data to System Default. All new systems must be reset to default before any programming in case corruption has been caused during handling or shipping. It will also be necessary to reset to default after a software upgrade is installed. When using item 3 or 4 these must be done AFTER the system reset is performed.
Description:
1 = System data will be reset to system default except System Speed Dial
Programming.
2 = The system data will be totally reset to system default.
WARNING: All user defined data will be lost.
3 = For all Stations set
44-st-02=1 (Hold Feature restricted)
44-st-03=1 (Call Split Feature restricted)
This feature is for Hotel/Motel operation. After setting this Form it is necessary to reprogram the Console and any Administration phones in Form 44-st-02 to allow them to place calls on hold.
4 = For all stations set
40-st-01=0 (Barge In not allowed)
40-st-02=0 (Monitor not allowed)
It is strongly recommended that this parameter is used on ALL systems to prevent accidental
Barge In operations being misinterpreted as crosstalk.
All other system programming information remains unchanged when using 3 or 4.
5= Clear all registered CT2 Handsets and restart all CT2 Base Stations(CFP). (Not currently used in North
America).
6= Restart all CT2 Base Stations(CFP). (Not currently used in North America).
7 = Spare
8 = Clear all timers for VSU Remote Programming
SK-200 Lodging Package Installation & Programming Page 99
Program 26-gp-IP : DID Route Table (Analog Indial) (Not used in North America)
26-000 DID ROUTE
cd = 000-999
000
<- Setting Data
Program 27-tk-IP : Print Programming Data
27-01-IP
0 0 0 0 0 0 0 0
IP = 01-99
System Default
General:
This program permits programming information to be passed to a serial printer via the system's RS232 port on the
SK-200.
Description:
00
01-98
99
=
=
=
Stop printing out data
Print out the programming forms individually
Print out all programming data
If a serial printer is connected to the MPU serial port, the system programming can be sent to the printer to provide a hard copy for record purposes.
Page 100
Program 29-tk-IP : Trunk Specifications - 2
29-tk-IP TK SPEC
0 0 0 0 0 0 0 0
tk = 01-08, IP = 01-08
System Default
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-1
0-8
0-3
0-9,d
0-9
0-1
0-
0-
Programming Data Description
Place Calls On Hold Awaiting Answer
ACD-1 Function Enable
ISDN Incoming Call type (Reserved for North America)
Set Ring Frequency (SK H/sets Only)
Allow Audible Ring For Incoming Calls
Trunk Timer Start Time
Reserved
Reserved
Default
0=Disable
0=Disable
0=Inblock sending
0=H/set Setting
0=All Stns
0=Line Loop
0=
0=
General:
This program permits each trunk line to be assigned different parameters.
Description:
Item 01 - Place Calls On Hold Awaiting Answer:
This parameter requires the exchange to provide a polarity reverse signal on B party answer. If this is available the call can be placed on hold awaiting answer and then the system will notify the caller when the called party has answered.
0 = Disable 1 = Enable
SK-200 Lodging Package Installation & Programming Page 101
Item 02 - ACD-1 Function Enable:
This parameter enables or disables the ACD-1 function for each trunk individually and is able to select whether
ACD-1 operates in Day or Night or Both Modes.
0
1
=
=
Day Time - Disable ACD function
Day Time - Disable ACD function
Night Time - Disable ACD function
Night Time - Enable ACD function
*1
7
8
9
4
5
2
3
6
=
=
=
=
=
=
=
=
Day Time - Disable ACD function
Day Time - Enable ACD function
*1
Day Time - Enable ACD function
*1
Day Time - Enable ACD function
*1
Day Time - Enable ACD function
*2
Day Time - Enable ACD function
*2
Day Time - Enable ACD function
*2
Reserved for future use.
Night Time - Enable ACD function
Night Time - Enable ACD function
Night Time - Enable ACD function
*2
Night Time - Disable ACD function
Night Time - Enable ACD function
*1
Night Time - Enable ACD function
*2
Night Time - Disable ACD function
*1
*2
*1:
*2:
Enable ACD-1 function only when all ring assigned stations are busy.
Enable ACD-1 function when time set in form 05-09-06 has elapsed even if the ring assigned stations are idle.
Item 03 - ISDN Incoming Call Type: (Reserved for North America)
Item 04 - Set Ring Frequency (SK 1/sets Only):
This feature allows each trunk to ring at AK handsets with it’s own individual ring frequency and override the frequency set by the user for all calls.
0
1~8
=
=
As per the key phone’s ring setting (user defined on AK handset)
Use the ringing frequency 1~8 of key phone (AK types) as the trunk’s ring d = Use “Background Music” as the Door phone’s ring
Page 102
Item 05 - Allow Audible Ring For Incoming Calls:
This feature allows either some or all stations which are ring assigned in Form 01 or 02 to receive the audible ring signal when a trunk rings at the station. If the audible signal is disabled the station will still be able to answer a call by lifting the handset only, if they are ring assigned in Form 01 or 02
0
1
2
=
=
=
All stations assigned in Form 01 & 02 will receive audible signal for an incoming call
Only the first station assigned in Form 01 & 02 will receive audible signal for an incoming call. the other ring assigned stations will still be able to answer a call by lifting the handset only
The first 2 stations assigned in Form 01 & 02 will receive audible signal for an incoming call. the other ring
9 = assigned stations will still be able to answer a call by lifting the handset only
The first 9 stations assigned in Form 01 & 02 will receive audible signal for an incoming call. the other ring assigned stations will still be able to answer a call by lifting the handset only
Item 06 - Trunk Timer Start Time:
This parameter allows each trunk to be set as to whether the timer starts when the line is looped or when a polarity reversal signal is received. If Form 14-01-08 is set to 1 then all trunks will start their timer when a polarity reverse signal is received otherwise only the trunks set to 1 in this parameter will start their timer when the reversal is received. See also Form 05-13-03 for call cut off timer if no polarity reverse signal is received.
SK-200 Lodging Package Installation & Programming Page 103
Program 30-gp-IP : (Not used in North America)
30-gp-IP DID INDEX
gp = 1-30, IP = 01 <- Setting Data
000
Program 33-gp-IP : (Not Used in North America)
33-gp-IP FLX DAY
000 000 000 000
gp = 01-30, IP = 01-16
<- Setting Data
Program 34-gp-IP: (Not Used in North America)
34-gp-IP FLX NIG
gp = 01-30, IP = 01-16
000 000 000 000
<- Setting Data
Page 104
Program 35-tk-IP : Trunk Specifications - 1
35-tk-IP TK SPEC
0 1 0 0 3 0 0 0
tk =(01-40), IP = 01-08
System Default
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-4
0-1
0-8
0-8
0-3
0-9
0-4
0-4
Programming Data Description
Trunk Type
Dialing Signal
External Call Forward
DISA
Pick Up
Loud Bell
Inward Line Ringing Type - Day
Inward Line Ringing Type - Night
Default
0=CO
1=DTMF
0=No
0=No
3=Yes
0=No
0=Com. Audible
0=Com. Audible
General:
This program permits every trunk line to be assigned different parameters.
Description:
Item 01 - Trunk Type:
0 = CO
1 = PABX
2 = DID
4 = ISDN
Trunk line is Central Office line.
Trunk line is installed behind a PABX or is a Centrex line.
Trunk line is a Analogue DID line. The system will automatically detect
the installation of a DID card and set this parameter itself.
Trunk line is ISDN The system will automatically detect the installation of an SIU card and set this parameter itself.
Item 02 - Trunk Signal:
0 = Pulse
1 = DTMF
Trunk dialing signal is Dial Pulse
Trunk dialing signal is DTMF (Touch Tone).
SK-200 Lodging Package Installation & Programming Page 105
Item 03 - External Call Forward - ECF:
0 = No ECF.
1
2
3
4
5
=
=
=
=
=
ECF to system speed dial 101
ECF to system speed dial 102
ECF to system speed dial 103
ECF to system speed dial 104
ECF to system speed dial 105
6
7
8
=
=
=
ECF to system speed dial 106
ECF to system speed dial 107
ECF to system speed dial 108
Item 04 - DISA/ECF (Direct Inward System Access/External Call Forward):
0
1
2
3
=
=
=
=
Day - Disable
Day - Disable
Day - DISA Enable
Day - DISA Enable
Night - Disable
Night - DISA Enable
Night - Disable
Night - DISA Enable
4
5
6
7
8
=
=
=
=
=
Day - Disable
Day - ECF Enable
Day - ECF Enable
Day - DISA Enable
Day - ECF Enable
Night - ECF Enable
Night - Disable
Night - ECF Enable
Night - ECF Enable
Night - DISA Enable
* Enable = Listed feature is operational.
Item 05 - Pick Up:
0
1
2
3
=
=
=
=
Day - can not
Day - can not
Day - can
Day - can
Night - can not
Night - can
Night - can not
Night - can
Can = An incoming call on this line can be answered by non ringing stations.
Can not = An incoming call on this line can not be answered by non ringing stations.
Page 106
This feature is to assign "Private Lines" in conjunction with the programming of dial 9 groups, or to prevent incoming calls being answered by users other than the ring assigned stations.
Item 06 - Loud Bell:
Refer to Program 06 to assign Relay to operate for a Loud Bell.
0
2
4
=
=
=
No Operation.
Relay 2 in cabinet 1
Relay 1 in cabinet 2
6
8
=
=
Relay 3 in cabinet 3
Relay 2 in cabinet 3
1
3
5
7
9
=
=
=
=
=
Relay 1 in cabinet 1
Relay 3 in cabinet 1
Relay 2 in cabinet 2
Relay 1 in cabinet 3
Relay 3 in cabinet 3
The system does not provide any voltage from the assigned relay. A separate ring voltage and ring device will need to be provided by the installer
Item 07 - Inward Line Ringing Method Assignment (Day):
As described in Program 01-tk-IP, there are four ringing methods plus a Private line setting:
COMMON AUDIBLE
Ring all assigned Extensions simultaneously.
LINEAR
Each incoming call rings the first available Extension in order of the Extensions assigned in Program 01-tk.
CIRCULAR
The first incoming call on each trunk rings the first assigned Extension, the 2nd incoming call rings the next station, etc.
HUNT
If an incoming line rings an extension which is busy or does not answer, after the assigned Hunt Time (Program 05-
08-01,) the call will ring the next available extension assigned in the same group. If the next ringing station is busy then the call will immediately move to the next ring assigned extension but if the station does not answer then the call will wait for the Hunt time and then ring the next assigned extension. Once the ring assignment has passed a station which is busy then it will provide Off Hook Busy Remind signal and when the station is free if the call is still unanswered the station will commence ringing for that call. Stations which do not answer a call will also continue to ring until the call is answered.
PRIVATE
This is for an incoming private line. The station that owns this private line can set the call forward (All, Busy, No
Answer) for this private line to the Voice Mail Port (See Program 43- ST-02).
0
2
=
=
Day - COMMON AUDIBLE
Day - CIRCULAR
1
3
=
=
Day - LINEAR
Day - HUNT
SK-200 Lodging Package Installation & Programming Page 107
4 = Day - PRIVATE
Page 108
Item 08 - Inward Line Ringing Method Assignment (Night):
As described in Program 02-tk-IP, there are four ringing methods plus a Private line setting: All settings in item 08 are the same as item 07.
0
2
=
=
Day - COMMON AUDIBLE
Day - CIRCULAR
1
3
=
=
Day - LINEAR
Day - HUNT
4 = Day - PRIVATE
SK-200 Lodging Package Installation & Programming Page 109
Program 36-gp-tk : Trunk Group Assignments
36-gp-IP TK GRP
gp = 01-08, IP =(01-40)
01 02 03 04 05
trunks to be included
General:
This program permits each trunk line to be assigned to different Trunk groups. There are eight groups in total.
Description:
In the bottom data-setting area, the trunk number (01-40) means that the trunk is included in the specified group.
Press REDIAL to clear all entries from the table before entering the required trunks. Always set outgoing calls to start from the highest fitted trunk and program in descending order to the lowest trunk fitted. This will prevent call collision particularly in systems with SLT'S.
There are 40 trunks maximum in a trunk group.
This parameter will work with the following features:
. Dial 9 or 0 access to trunk group.
. Tenant service.
. ACD-1 and DISA Grouping
Page 110
Program 37-tk : Busy Out Trunks
37-tk Busy Out
0 0 0 0 0 0 0 0
tk =(01-40)
Busy out Type
General:
This program permits the CO line to be locked by a Technician.
Description:
This feature is used when the user does not want to use the trunk or to remove a problem line. When the trunk is set to BUSY OUT, the LCD display on the phone will display "Access denied" when that line button is pressed.
2
3
0
1
=
=
=
=
Line is unlocked
Busy for Outgoing calls
Busy for Incoming and Outgoing calls (set loop on)
Busy for Incoming and Outgoing calls (set line LED on)
Program 38-gp-tk : Dial 87 Trunk Group Assignment
38-gp-IP TK GRP
gp = 01-08, IP =(01-40)
01 02 03 04 05
trunks to be included
General:
This program permits each trunk line to be assigned to different Trunk groups which can be accessed by dialing
[87]. There are 8 groups in total. This group will be available to a station in addition to it's dial 9 group. Always set outgoing calls to start from the highest fitted trunk and program in descending order to the lowest trunk fitted. This will prevent call collision particularly in systems with SLT'S. Press REDIAL to clear all entries in the table before entering required trunks.
Description:
This form is programmed in the same way as Form 36-gp-tk. But this program is only used for dialing [87] to access a Trunk Line.
Once a dial [87] group has been programmed it will need to be assigned to the stations who are to use it in Form
46-Stn-01.
SK-200 Lodging Package Installation & Programming Page 111
Program 39-IP : Sensor Assignment
39-gp-IP Sensor
00 00 00 00
gp = 01-04 IP = 01-04
System Default
Item
Pointer
01
02
03
04
Display
Data
00-18
00-18
0-6
0-6
Programming Data Description
SENSOR #1 of IPU Card
SENSOR #2 of IPU Card
SENSOR #1 Contact Type and Activating Time
SENSOR #2 Contact Type and Activating Time
Each group can be programmed the same as group 1 and the group number refers to the cabinet number in which the IPU supporting the sensors is installed.
Description:
Each IPU has 2 Sensors (SK-200).
Each Sensor can be assigned one of the following 18 functions in items 39-(01-02) in the SK-200.
Setting Function
00
01
02
=
=
=
No Operation
Fire Alarm
Break Alarm
03
04
05-18
=
=
=
Door Phone 1 ( 88 )
Door Phone 2 ( 89 )
Reserved for future use
The SENSOR type may be normally open or normally closed and can be set to be activated in Day or Night switching or in both. Parameters (39-gp-(03-04) in the SK-200 set each sensor contact to be a normally open or normally closed type and set whether to work in Day or Night Mode or both.
00
01
=
=
Disable Sensor function
Normally Open, Activated for Day time.
02
03
=
=
Normally Closed, Activated for Day time
Normally Open, Activated for Night time.
04 = Normally Closed, Activated for Night time.
Page 112
05
06
= Normally Open, Activated for Day and Night time.
= Normally Closed, Activated for Day and Night time.
The applications are as the following:
1 = Fire Alarm :Sensor detects fire, all idle extensions will be rung and all busy
extensions will hear the alarm tone.
2 =
.The fire alarm will continue for 10 minutes.
.Pressing [7][7][7] from the console will stop the fire alarm.
The LCD display will show FIRE ALARM !!!! when the alarm is activated.
Break Alarm
.The Sensor detects the signal appears, all idle extensions will be rung.
.The Sensor detects the signal disappears, all extensions will stop ringing.
The LCD display will show BREAK ALARM !!!! when the alarm is activated.
Individual stations can be programmed to not receive the Break Alarm in Form 45-st-06.
The ring cadence for the fire alarm will be as follows a = 1.25 seconds on b = 0.25 seconds off
This cadence repeats.
!
" # $ # % & " c = 0.25 seconds on. b = 0.25 seconds off
!
' " ' (
,
.
) *
" '
" ' .
/
-
"
#
#
# ,
+ "
"
!
'
'
!
'
+ "
+ "
SK-200 Lodging Package Installation & Programming Page 113
Program 40-st-IP : Station Class of Service - 1
40-st-IP STCOS
1 1 0 0 0 0 0 00
(Keysets)
0 0 0 0 1 0 0 00
(Single Lines)
st = Extension NO.(2-4 digits). IP = 01-08
System Default
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-9
0-9
0-9
0-3
0-1
0-1
0-1
00-48
Programming Data Description
Override Level
Monitor Level
Limit Call Duration
Station Loud Bell
Access Paging
Receive Paging
Security Code Status
Forced Account Code
Default
1=Low
1=Low
0=No
0=No
0=Yes
0=Yes
0=None
00=All
General:
This programming Form permits each station to be assigned a different Class of Service.
Description:
Item 01 - Override Level:
Higher level stations can override lower level stations, equal levels may override each other. All values between 1 and 9 are valid.
0 = Disable 1 = Lowest level 9 = Highest level
Item 02 - Monitor Level:
Higher level stations can monitor lower level stations, equal levels can not monitor each other. All values between
1 and 9 are valid.
0 = Disable 1 = Lowest level 9 = Highest level
Item 03 - Limit call duration:
Conversation will be interrupted by a Busy Tone. A warning tone will be given 10 seconds before the end of the timed duration. (see Form 05-04-03 to set call limiting action)
Page 114
0 = No limit
5 = 20 min
1 = 3 min
6 = 30 min
2 = 5 min
7 = 40 min
3 = 10 min
8 = 50 min
4 = 15 min
9 = 60 min
Item 04 - Station Loud Bell:
Refer to Program 06 to assign Relay to operate for a Loud Bell.
0
2
4
6
8
=
=
=
=
=
No Operation
Relay 2 in cabinet 1
Relay 1 in cabinet 2
Relay 3 in cabinet 3
Relay 2 in cabinet 3
Item 06 - Be Paged:
0 = "All Page" signal can be received by this station.
1
3
5
7
9
=
=
=
=
=
Relay 1 in cabinet 1
Relay 3 in cabinet 1
Relay 2 in cabinet 2
Relay 1 in cabinet 3
Relay 3 in cabinet 3
The system does not provide any voltage from the assigned relay. A separate ring voltage and ring device will need to be provided by the installer
Item 05 - Access Paging:
0 ="All Page" signal can be broadcast by this station. 1 = "All Page" signal can not be broadcast by this station.
1 = "All Page" signal can not be received by this station.
This feature is useful for someone who does not want to be disturbed by page calls.
Item 07 - Security code status:
0 = The station is unlocked.(Can make outgoing calls.) 1 = The station is locked. (Can not make outgoing calls.)
If a phone becomes locked accidentally or the user forgets their lock code, this parameter will unlock the phone.
There is no way of finding what the lock code was.
Item 08 - Forced account code:
There are 99 forced account codes which can be used on the system. Each user can be allocated use of one or all of these. If a station has a Forced Account Code (01-48)(01-99), the user can key [SAVE] [MW] and the account code to override toll restrictions for one call only.
If the setting is from (01-48)(01-99) then this Account Code ONLY can be used by the station. If the setting is 00 then the station can use any one or all Account Codes.
Refer to Form 17: Create Forced Account Code
SK-200 Lodging Package Installation & Programming Page 115
Program 41-st-IP : Station Specifications
41-st-IP STSPE
1 3 0 1 0 0 CN
st = Extension NO.(2-4 digits). IP = 01-07
System Default
Item
Pointer
01
02
03
04
05
06
07
Display
Data
1-8
1-8
0-8
1-8
0-9,d
0-9,d csn
Programming Data Description
Station Group / Agent Group for ACD
Key Group For KeyPhone
Shift Key Group For KeyPhone
Dial 9 trunk group
Toll plan - Day
Toll plan - Night c = Cabinet numbers = Slot Number, n = Port number
Default
1=1
3=3
0=None
1=1
0=0
0=0
General:
This program permits each station to be assigned to a different Class of Service.
Description:
Item 01 - Station group:
This parameter will work with the following features:
- Call Pickup Group.
- Single Digit Intercom Group
- Paging Group
- ACD-1 Group
Item 02 - Flexible key pattern group assignments (key phone):
This parameter assigns stations to one of 8 flexible key pattern groups.
See Form 07: Flexible key group assignment to write soft key plans.
Item 03 - Shift Key Group For KeyPhone:
Each station can have access to a second soft key group accessed by the shift key. The shift key must be programmed in the first group assigned to the station. When the shift key is used to access the second group then it will light red and over ride the function assigned to it in the second group.
0 = Disable 1-8 = Soft Key Plan 1 to 8
Page 116
Item 04 - Dial 9 trunk group:
When a station selects a trunk line by dialing 9, the system finds an available trunk according to the dial 9 group assignment. If a trunk is not in a stations assigned dial 9 group then the station will not be able to make outgoing calls on that trunk.
Item 05 - Toll plan - Day:
This parameter assigns the toll plan to be used by the station in day mode.
Refer to Form 18 for Toll plan details.
Item 06 - Toll plan - Night:
This parameters assigns the toll plan to be used by the station in night mode.
Refer to Form 18 for Toll plan details.
Item 07 - Port number:
This is for checking only, the system will automatically show the correct port number. It is not possible for the user to change or remove this parameter.
In the SK-200 the port number consists of 3 digits, The first is the cabinet number (1 to 4), the second is the slot number in the cabinet (0-9) and the third is the position on the card (1 to 8).
SK-200 Lodging Package Installation & Programming Page 117
Program 42-st-IP : Register Memory Block for Individual Speed Dial
42-st-IP SPD-T b1 b2
st = Station No. (2-4 digits) IP = 01-02
blocks (2 max.) for a Station
b1:
b2:
Block 1 of Individual Speed Dial Codes (00-09)
Block 2 of Individual Speed Dial Codes (DSS1-10)
General:
This program divides sets of Individual Speed Dial into blocks for use by Stations.
Description:
In program 05-04-06, divide the 500 (900 for SK-200) sets of Speed Dial into System or Individual Speed Dial.
If in program 05-04-06, the Individual Speed Dial Codes are assigned:
900 sets, maximum blocks are 90 blocks. 800 sets, maximum blocks are 80 blocks
700 sets, maximum blocks are 70 blocks 600 sets, maximum blocks are 60 blocks
500 sets, maximum blocks are 50 blocks 400 sets, maximum blocks are 40 blocks
300 sets, maximum blocks are 30 blocks
Each block has 10 sets of Individual Speed Dial.
Each set has up to 30 digits.
Each Station can use up to 2 blocks (20 sets of Individual Speed Dial.)
Example:
42-553-IP SPD-T 553: Station No. ( 2-4 digits )
01 02
01 02: Station 553 can use block 01 and 02 for
Individual Speed Dial (20 sets)
42-105-IP SPD-T
04 00
105: Station No. ( 2-4 digits )
04 00: Station 105 can use block 04 (10 sets) for
Individual Speed Dial (00-09), 00 : for no block.
42-550-IP SPD-T
00 03
550: Station No. ( 2-4 digits )
00 03: Station 550 can use block 03 for Individual
Speed Dial (DSS 1-10)
* Refer to KeyPhone Operation, for the programming of Individual Speed Dial.
* Be sure to program these parameters before programming speed dial on key phones.
If problems are encountered with stations not being able to program speed dial numbers, check this parameter to be sure that speed dial locations are available to the station. If the station card was fitted at the time of system
Page 118
initialisation then the blocks will have been allocated automatically.
SK-200 Lodging Package Installation & Programming Page 119
Program 43-cn-IP : Port Specifications
43-csn-IP Port st 0 1 2 00 00
csn = Port No. (3 digits) IP = 01-06
Parameters for the port
csn c = Cabinet number(1-3) s = Slot Number(0-9) n = Position Number on Card
Item Display
Pointer Data
01
02
03
04
05
06 nnnn
0-9
1-8
0-8
00
00
Programming Data Description
Station Number (2 to 4 digits)
Equipment Type
DSS Key Group Assignment
Disallow SLT Connection
Reserved
Reserved
Default
System
System
1=Grp.1
0=Yes
00
00
General:
This program permits each port to be assigned different parameters and station numbers.
Description:
Item 01 - Station number:
Use this setting to assign station numbers for the Flexible Numbering Plan.
This parameter also assigns the DSS console to the station which is to control it. To assign the DSS control station, first ascertain which port the DSS console is connected to, then enter this Port number and then enter the number of the station which will control it in the first position on the screen. It may be necessary to connect the DSS console to the system and then power down and re power the system to allow proper recognition of the DSS unit.
02. Equipment type:
0 = None connected
2 = KeyPhone (25 key with LCD)
4 = Single Line Telephone
6 = Reserved
8 = Voice Mail Port
1 = KeyPhone (25 key without LCD)
3 = Dual port/Hybrid port no KeyPhone
5 = DSS Console
7 = KeyPhone With OHCA
9 = ISDN Extension
Types 0 to 5 are recognised by the system automatically.
Type 3 can be assigned to an analog port on a SK-200 and that port can then be given the same Station number as a Key Phone which will enable operation of the 2 phones in the same way as a Hybrid port on SK-824
Page 120
with dual port capability enabled.
Type 8 can be assigned to an analog port to enable the system to send DTMF tones identifying a call forwarded calls originating station. A Voice Mail port will receive DTMF tones from call forwarded stations identifying the mail box to which the call is intended. The mail box number must be the same as the station number for this parameter to work although Mode 05-10 can insert leading digits before the station number is sent to the Voice Mail and is also able to insert pauses before or during the string. There is also an Enhanced Protocol to provide more information to the Voice Mail unit, see Mode 05-10 for descriptions of the protocols available.
Item 03 - Key pattern group assignments for DSS:
This parameter assigns DSS consoles to the pattern group.
See Program 08 to create or modify flexible DSS key patterns.
Item 04 - Disallow SLT Connection:
This parameter when enabled will prevent an SLT from being used on a Hybrid port.
0 = Disabled 1 = Enabled
Item 05 - Reserved:
Item 06 - Reserved:
To set an extension name -
1. Enter system programming Form 43.
2. Depress [MIC/AT] to enter the Name form.
3. Input the name for the related extension by the following function keys.
Key Pad
1
2
3
4
5
6
7
8
9
0
*
#
Depress
1 time
Q
A
D
G
J
M
P
T
X
.
-
(
Depress
2 times
Z
B
E
H
K
N
R
U
Y
:
/
)
Depress
3 times
Space
C
F
I
L
O
S
V
Z
&
!
$
Depress
4 Times
1
2
3
4
5
6
7
8
9
0
*
#
DSS23
Cursor Left
DSS24
Cursor Right
4. Press [SAVE] to store the data.
5. The next extension port will appear ready to program names.
SK-200 Lodging Package Installation & Programming Page 121
Program 44-st-IP : Station Class of Service - 2
44-st-IP STCOS
0 0 0 0 0 0 0 0 (Key Telephones)
0 1 0 0 0 0 0 0 (Single Line Phones)
st = Station No. (2-4 digits)
IP = 01-08
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-1
0-1
0-1
0-1
0-1
0-1
0-1
0-1
Programming Data Description
System Alarm
Hold feature
Call Split
Manual Line
Headset feature
Use Engineering Password
DTMF Receiver Control For Voice mail Ports
Station Alarm Signal Type
General:
This program permits each station to be assigned to a different Class of Service.
Description:
Item 01 - System Alarm:
If the setting is disabled, the station will not receive system alarm clock signals.
0
1
=
=
The "System Alarm" signal will be received on this station.
The "System Alarm" signal will not be received on this station.
Item 02 - Hold feature:
If the setting is disabled, the station will not be able to place calls on hold.
0
1
=
=
Hold function allowed
Hold function not allowed
Item 03 - Call Split:
Page 122
Default
0=Enable
0=Enable
0=Enable
0=Disable
0=Disable
0=Enable
0=Normal
0=Music
If the setting is disable, the station will not be able to activate call splitting function. When activated and the station presses hook flash after placing a call on hold the call will not be retrieved. Dialing 9 (or 0) or 72 will retrieve the held call.
0
1
=
=
Call Splitting function allowed
Call Splitting function not allowed
Item 04 - Manual Line:
If the setting is Enable, lifting the handset of the station will call the operator directly without dialing any digits.
0 = Disable 1 = Enable
Item 05 - Headset feature:
If this setting is enabled it will be necessary to leave the handset of the key station off hook. The user can then use the [SPK] key to go on or off hook. If the station is a headset phone then it is not necessary to leave the handset off hook
This programming form will be overwritten by the user if they use [SPK 775] to switch between handset and headset form.
0 = Disable 1 = Enable
Item 06 - Use Engineering Password:
If the setting is disable the station is unable to use the engineering password to enter programming form.
The engineering password is 117277.
0 = Enable 1 = Disable
Item 07 - DTMF Receiver Control For Voice mail Ports:
This program controls the operation of DTMF detectors for each Voice mail Port. The parameter is set to free
DTMF detectors quickly for systems with high Voice Mail traffic.
0 = After the Voice Mail dials the extension number, The system releases the DTMF receiver after the
1 = timeout of form 05-02-02
After the Voice Mail dials the extension number, The system releases the DTMF receiver immediately
Item 08 - Station Alarm Signal:
This parameter decides what the station will hear when a station alarm or Morning Call is activated.
0 = Back Ground Music 1 = Busy tone
SK-200 Lodging Package Installation & Programming Page 123
Program 45-st-IP : Station Class of Service - 3
45-st-IP STCOS
st = Station No. (2-4 digits) IP = 01-08
0 0 0 0 0 0 0 0
System Default
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-1
0-1
0-1
0-1
0-1
0-1
0-1
0-1
Programming Data Description
Intercom Call Limitation
Dual Port Capability
Ringing Volume Up Gradually
Allow Trunk Access
Intercom Calls To Different Station Groups
Receive Break Alarm
Allow Unrestricted Speed Dial
Record Station's SMDR Data
Default
0=Disable
0=Disable
0=Disable
0=Yes
0=Yes
0=Yes
0=Yes
0=Yes
General:
This program permits each station to be assigned to a different Class of Service.
Description:
Item 01 - Intercom Call Limitation:
If this setting is Enabled, the station can not make an intercom call by dialing a station number. Under this condition, the Key Phone still can press a Flexible Key to make an intercom call or the Key Station or Analogue phones can call a station using the "Single Digit" feature.
0 = Disable 1 = Enable
Item 02 - Dual port Capability:
If this function is enabled, a Single Line Telephone can be parallelled with the Key Telephone to a Hybrid Extension
Port.
0 = Disabled (No Parallel connection) 1 = Enabled (Parallel connection Allowed)
Item 03 - Ringing Volume Up Gradually Capability:
Using this function, the key telephone's ringing volume will gradually increase when the Extension is ringing.
0= Disable 1= Enable
Page 124
Item 04 - Allow Trunk Access:
If this function is disabled then the station will be unable to access any trunks for incoming or outgoing calls.
0 = Enable 1 = Disable
Item 05 - Intercom Calls to Different Station Groups:
If this function is disabled then stations will not be able to make intercom calls outside their own station group
(Form 41-st-01). This parameter is for use in tenancy arrangements where each company wish's to remain totally separate although some stations can still be allowed this function, for instance a shared Receptionist.
0 = Enable 1 = Disable
Item 06 - Receive Break Alarm:
If this parameter is disabled then the station will not receive the Break Alarm signal if one has been programmed in
Form 39.
0 = Enabled 1 = Disable
Item 07 - Allow Unrestricted Speed Dial Access:
If this parameter is disabled then the station will not be able to access any of the Speed Dial numbers which have been unrestricted in Form 05-05-03/04 if they conflict with the stations toll restrictions.
0 = Enabled 1 = Disable
Item 08 - Record Station's SMDR Data:
If this parameter is disabled then calls to and from this station will not recorded or output to the SMDR or the Mini
Accounting feature. When the Mini Accounting feature is enabled (see Form 14-01-08) then all stations which are used for administration should have this feature disabled to prevent using memory unnecessarily to record their calls. If calls are allowed to accumulate against stations which are not checked in or out regularly then the system memory buffer will become full and calls will not be recorded.
0 = Record 1 = Do not Record
SK-200 Lodging Package Installation & Programming Page 125
Program 46-st-IP : Station Class of Service - 4
46-st-IP STCOS
0 1 0 0 0 7 0 0 (Key Telephones)
0 1 0 0 0 7 2 0 (Single Line Phones)
st = Station No. (2-4 digits) IP = 01-08
System Default
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-8
0-9
0-2
0-7
0-9
0-1
0-2
0
Programming Data Description
Dial [87] Trunk Group
Send Message Wait Signal Level
Automatic Microphone Switching
DISA /DID/Indial Recall Capability
Maximum Number Of Transfer Times Allowed
Door Lock/DND/CFWD Access
Telephone Software Version
Reserved
Default
0=None
1=Low
0=No
0=None
0=No Limit
7=Yes
0=1
0
General:
This program permits each station to be assigned to a different Class of Service.
Description:
Item 01 - Dial [87] Trunk Group:
If this setting is from 1 to 8, after the station dials [87], the system will automatically search for a free line which is assigned in group 1 to 8 in Program Form 38.
If the setting is 0, then no dial 87 group is available to this station.
Item 02 - Message Waiting Level:
The Stations assigned higher levels can leave message for stations with the same or lower levels. Ten levels (0-9) are available (9=highest level, 0=lowest level).
0 = Can not do Message Waiting (lowest level). 9 = Can do Message Waiting to Stations assigned level 0-9
Item 03 - Automatic Answer Capability:
This parameter if enabled will automatically switch on the microphone of the station if it receives an intercom call.
This setting is independent of whether the system is set to voice or ring signaling for intercom calls.
Page 126
0 = No 1 = MIC permanently on 2 = MIC will switch on for Intercom calls
SK-200 Lodging Package Installation & Programming Page 127
Item 04 - DISA/DID/Indial Recall Capability:
If this parameter is enabled then when a DISA, DID or ISDN Indial call rings the extension but the station is busy or does not answer (depending on setting) after the voice message announcing the status of the station is heard then the system will recall the operator after the assigned DISA transfer time. Using settings 1 to 3 the called station will continue to ring until the console answers the call. Using Settings 5 to 8 the call will ring the station for 1 cycle
(Form 05-08-06) and then camp on to the console only and cease to ring the called station. If the parameter is set to 0 then the call will stay at the station until answered or terminated..
0 = No Recall to Operator
2 = Recall to Operator/Busy
1 = Recall to Operator/No Answer
3 = Recall to Operator/No Answer or Busy
4 = An ISDN Indial call to this station will receive Busy signal if the station is busy
6 = Recall to Operator/Busy
5 = Recall to Operator/no Answer
7 = Recall to Operator/No Answer or Busy
Item 05 - Maximum Re-Transfer Times:
This feature allows the user or the automatic attendant console to re-transfer the same call for the number of times set in this parameter.
0 = No Limit
2 = Allow 7 times
1 = Allow 6 times
3 = Allow 8 times
4 = Allow 9 times
6 = Allow 11 Times
8 = Allow 13 times
5 = Allow 10 Times
7 = Allow 12 Times
9 = Allow 14 times
Item 06 - Door Unlock/DND/CFWD Access:
Door
0
0
1
1
2
0
Unlock
DND 0 0 1
CFWD 0 0 0
3
1
1
0
4
0
0
1
5
1
0
1
6
0
1
1
7
1
1
1
This parameter allows or disallows the station from accessing the Door Unlock, Do Not Disturb and Call Forward features as per the table. (0= Disable 1=Enable)
Item 07 - Telephone Software Type:
This parameter sets the different versions of for SK software equipped telephones. This parameter must be changed manually. All systems should be set to a 2 for SK-1 telephones.
Page 128
Program 47-st : Hot line Assignment
47-st HOT LINE
000
47-st HOT LINE
SPD:000
47-550 HOT LINE
151
st = Station No. (2-4 digits)
Data. ( Extension Mode )
st= Station No. (2-4 digits)
Data. ( SPEED DIAL Mode )
General:
This feature allows a user to lift the handset and directly call a specific outside party through System Speed Dial or an Intercom Extension without dialing any digits.
* Pressing [SPK] on a KeyPhone allows the Hot line to be over-ridden.
Description:
1. Enter a System Speed Dial Number for an outgoing call or a Station Number for an Intercom call.
Example:
47-550 HOT LINE
SPD:101
550 = Station No. ( 3 digits )
Speed Dial 101 (for example: 3190255)
When the user lifts the handset, the System will automatically call 3190255 through System Speed Dial 101.
2. Press [MIC] to select a hot line Intercom. (Press again back to SPD assignment), the display shows:
47-550 HOT LINE
Enter an Extension number 151
000
The system calls Extension 151 when the handset is lifted.
The Hot Line is the recommended method of connecting a Fax machine to the system. Use a spare analogue port and make the Fax extension a Hot Line to an unused Speed Dial number and allocate the fax line to be used by that Speed Dial. Do not program any number into the Speed Dial. When the fax goes off line it will select the Fax line and then wait for the Fax to dial the number required.
SK-200 Lodging Package Installation & Programming Page 129
Program 48-st-IP : Register Memory Blocks for Function Keys
48-st-IP FUN-T st = Station No. (2-4 digits) IP = 01 b1
block (1 max.) for a Station
b1:(00-99) Block for DSS Function Keys (DSS keys 16-24)
General:
This program allocates memory blocks for use by DSS function keys on individual Key Stations.
Description:
Each block provides memory for programming 9 DSS function keys per station. The DSS keys for functions are the
4 leftmost keys of the top row and the second top row of the KPU handset.
Each memory block allows up to 5 key strokes to be stored by each DSS key.
There are 99 blocks available for assignment.
Program 49-st-IP : Register Credit Limit (SK-200)
49-st-IP Credit
0 0 0 0 0 st = Station No. (2-4 digits) IP = 01
< set credit limit for each Station
General:
This feature is for Hotel/Motel installations and allocates credit limits for individual stations when meter pulse detection is fitted to the system.
Description:
This feature allows each individual station to be set a limit on the cost of calls able to be made. When this limit is reached the phone will be automatically Checked Out (locked) by the system and no further calls can be made from it. The call in progress can continue. The credit limit can be set using Hotel Function Key [9] so this programing mode will not normally be used however it is possible to scroll through the program to see what limits are set for stations and also to clear them if needed.
Page 130
Program 50-st-IP : Station Class of Service - 5
50-st-IP STCOS
0 0 0 0 0 0 0 0
st = Station No. (2-4 digits) IP = 01-08
System Default
Item
Pointer
01
02
03
04
05
06
07
08
Display
Data
0-1
0-1
0-1
0-1
0
0
0
0
Programming Data Description
Disable SPK/HOLD/TRF Key
Call Forward LED Indicator
ISDN Incoming Call Display Type
Reserved
Reserved
Reserved
Reserved
Reserved
Default
0=no
0=Yes
0=CLI
0
0
0
0
0
General:
This program permits each station to be assigned to a different Class of Service.
Description:
Item 01 - Disable SPK/HOLD/TRF Key:
This parameter when enabled will prevent the operation of the SPK/HOLD/TRF keys. If a KeyPhone is being used for a door phone or courtesy phone or an application where the user should be prevented from accessing system features this feature will be useful.
0 = Enable 1 = Disable
Item 02 - Call Forward LED Indicator:
This parameter enables or disables the indication of “Call Forward” on the large LED indicator of key telephones.
0 = Show “Call Forward” on big LED of key telephone 1 = Do Not Display
Item 03 - ISDN Incoming Call Display Type):
This parameter selects what will be displayed on the screen of an LCD phone when an incoming call is received, either the CLI number or the ISDN Indial number. CLI on PSTN lines requires optional equipment to be fitted. This will also select what will be displayed on the SMDR output for incoming calls.
0 = CLI 1 = ISDN Indial Number
SK-200 Lodging Package Installation & Programming Page 131
Program (51 to 56)-code-IP : Toll Plans - Allowed Digits - Class 1 to 6
51-code-01 Allow
- - - - - - - - - - -
code = code no 01-16(20), IP = 01-08(12)
< System default
General:
This program sets allowed exception numbers for Toll Class 1. These Forms should be read in conjunction with
Forms 61 to 66.
Description:
There are 16 codes for each Toll Class and each code contains up to 12 digits
In default any station allocated to Toll Plans 1 to 6 will be able to dial unrestricted until the associated Forms are programmed.
Allowed entries in this Form are 0 to 9, d and _. d = Don't care and means that any digit can be dialled in this position. _ = no digit is allowed to be dialled beyond this position. If a digit is allowed as the beginning of a number then the entry should be filled with don't care's to the end of the line or the caller will not be able to dial the full number.
Forms 51 to 56 are used in conjunction with Forms 61 to 66 and Forms 57 to 59 are used independently.
Toll Classes:
Class Function Prog. Form
0
1
Unrestricted
Use Form 51 for the Unrestricted numbers. Use Form 61 for the Restricted numbers
Default
Form 51,61
2 Form 52,62
Use Form 52 for the Unrestricted numbers. Use Form 62 for the Restricted numbers
3 Form 53,63
4
5
Use Form 53 for the Unrestricted numbers. Use Form 63 for the Restricted numbers
Use Form 54 for the Unrestricted numbers. Use Form 64 for the Restricted numbers Form 54,64
Form 55,65
6
7
8
9
Use Form 55 for the Unrestricted numbers. Use Form 65 for the Restricted numbers
Use Form 56 for the Unrestricted numbers. Use Form 66 for the Restricted numbers
Use Form 57 for the Unrestricted numbers.
Use Form 58 for the Unrestricted numbers.
Use Form 59 for the Unrestricted numbers.
Form 56,66
Form 57
Form 58
Form 59
d Cannot access the trunk line.
Note 1: Default numbers in Form 61, 62, 63, 65, 66 are: dddddddd
Note 2: Default numbers in Form 51, 52, 53, 55, 56, 57, 58, 59 are:------------
Note 3: d: Don't care ie: any digit is allowed in this position.
Page 132
Note 4: _: The system does not allow any digits dialled after this symbol.
SK-200 Lodging Package Installation & Programming Page 133
Program (61 to 66)-code-IP : Toll Plans - Restricted Digits - Class 1 to 6
61-code-01 Restrict
code = code no 01-16(20), IP = 01-08(12) d d d d d d d d
< System default
General:
This program sets Restricted numbers for Toll Class 1. These Forms should be read in conjunction with
Forms 51 to 56.
Description:
There are 16 codes for each Toll Class and each code contains up to 8 digits
In default any station allocated to Toll Plans 1 to 6 will be able to dial unrestricted until the associated
Forms are programmed.
Allowed entries in this Form are 0 to 9, d and _. d = Don't care and means that any digit can be dialled in this position. _ = no digit is allowed to be dialled beyond this position. If a digit is allowed as the beginning of a number then the entry should be filled with don't care's to the end of the line or the caller will not be able to dial the full number.
Forms 51 to 56 are used in conjunction with Forms 61 to 66 and Forms 57 to 59 are used independently and do not have an associated restriction table.
In Default stations which are allocated Toll Plans 0 to 6 are able to dial any numbers.
When a station is allocated Toll Plans 7 to 9 they can dial no digits until the plans are programmed.
Form 51 and 61 combine to produce Toll Plan 1, Form 52 and 62 combine to produce Toll Plan 2 and so on up to Form 56 and 66 for Toll Plan 6. Toll Plans 7, 8 and 9 are associated with Form 57, 58 and 59.
The principle of these Toll Plans up to Plan 6 is to deny unwanted digits in Form 61 to 66 and then allow any exceptions for these digits in Form 51 to 56. If 0ddddddd is entered in Form 61 and 000_and 013 are entered in Form 51 then a station allocated to Toll Plan 1 will be able to dial any local number plus 000 for emergency and 013 for Directory assistance. Any other number beginning with 0 will be disallowed.
Example 1: Local calls and free calls.
Set Form 41-111-05/06 = 1
When this form is set and Form 51 and 61 are still at default then station 111 will still be unrestricted.
Set Form 61 to the following,
Form 61-01 = 0___________
Form 61-02 = 1ddddddddddd
Station 111 will now be only able to dial numbers beginning with digits 2 to 8.
To allow local and free calls program Form 51 to the following.
Form 51-01 =1800dddddddd
Form 51-02 =1888dddddddd
Form 51-03 = 1877dddddddd
Page 134
Program (57 & 58)-code-IP : Toll Plans - Allowed Digits - Class 7 & 8
57-code-01 Allow
- - - - - - - - - -
code = code no 01-16(20), IP = 01-08(12)
< System default
General:
This program sets allowed numbers for Toll Plans 7 to 9.
Description:
There are 16 codes for each Toll Class and each code contains up to 12 digits. In default any station allocated to this toll plans will not be able to dial any numbers.
When this form is set and Form 57 is still at default then station 111 will be totally restricted.
Program 59-code-IP : Toll Plan - Common Permitted Code - Class 9
59-code-01 Allow
- - - - - - - - - -
code = code no 01-16, IP = 01-12
< System default
General:
This program sets allowed numbers for ALL Toll Plans 0 to 9.
Description:
Up to 16 Common Permitted Codes can be entered and each code contains up to 12 digits. Any number entered in the common permitted code can be dialled by any station regardless of the Class of service they have been allocated. In default the Common Permitted numbers allocated in this table are 000 and 1144d.
SK-200 Lodging Package Installation & Programming Page 135
Program 67-Gp-IP : Hunt Group Pilot Number
67-gp HUNT NO
000
GP = 01-10
< System default
General:
This program sets Pilot Numbers for Hunting Groups 1 to 30.
Description:
There are 30 Hunt Groups available in SK-200. Each Hunt Group is assigned a Pilot Number in this Form.
The pilot number can be any valid unused number and will have the same number of digits as the station numbering scheme used in the system (2, 3 or 4).
Hunt group pilots can be assigned to be rung from Single Digit DISA.
Once Hunting Ring Type is enabled in Form 05-08-08 then ringing this pilot number will access the stations in the group according to the ringing method selected and the order in which they are programmed in Form
68 (Day) and Form 69 (Night). Each Hunt Group can be from 1 to 16 stations in the SK-200.
There are 3 types of Ring available, Common Audible, Linear and Circular.
If Linear Ring is enabled then calling the pilot number will always call the first available station in the order in which they are programmed in Form 68 or 69.
If Circular Ring is enabled then the stations will be called one after the other for each succeeding call until all have taken a call and then the Ring will revert to the beginning of the Ring assignment and then repeat the process.
If Common Audible Ring is enabled then calling the pilot number will call all ring assigned stations simultaneously.
Stations can remove themselves from receiving Hunt calls by using the DND key but this will also prevent them from receiving direct calls. On the SK-200 stations can be given a function key to Log
In or Out of the hunt group. This key is programmed in Form 07-Grp to be function key 64.
It is still possible to call each station in the Hunting group directly by dialing it's own individual station number.
If a station in a Hunt Group has set call forward to a station or another Hunt Group (for instance Voice Mail
Group) then only direct calls to the station will be forwarded. If Hunt calls come to the station and it is call forwarded it will still ring for the call.
Page 136
Program 68-Gp-IP : Hunt Group Assignment - Day
68-GP-IP HUNT DA
000
GP = 01-10, Ip = 01-05
< System default
General:
This program sets Stations into Hunting Groups 1 to to 30 for the SK-200 and assigns the order in which they will be accessed during Day time.
Description:
There are 30 Hunt Groups available and 16 stations can be assigned into each group for Day and 16 for
Night time.
There are 2 types of Ring available, Linear and Circular.
If Linear Ring is enabled then calling the pilot number will always call the first available station in the order in which they are programmed in Form 68 or 69.
If Circular Ring is enabled then the stations will be called one after the other for each succeeding call until all have taken a call and then the Ring will revert to the beginning of the Ring assignment and then repeat the process.
It is still possible to call each station in the Hunting group directly by dialing it's own individual station number.
Program 69-Gp-IP : Hunt Group Assignment - Night
69-GP-IP HUNT NI
000
GP = 01-10, Ip = 01-05
< System default
General:
This program sets Stations into Hunting Groups 1 to 30 for the SK-200 and assigns the order in which they will be accessed during Night time.
Description:
There are 30 Hunt Groups available and 16 stations can be assigned into each group for Day and 16 for
Night time.
There are 2 types of Ring available, Linear and Circular.
If Linear Ring is enabled then calling the pilot number will always call the first available station in the order in which they are programmed in Form 68 or 69.
If Circular Ring is enabled then the stations will be called one after the other for each succeeding call until all have taken a call and then the Ring will revert to the beginning of the Ring assignment and then repeat the process.
It is still possible to call each station in the Hunting group directly by dialing it's own individual station number.
SK-200 Lodging Package Installation & Programming Page 137
Appendix A - Name Function Programming
To set an extension name -
1. Enter system programming Form 43.
2.
3.
Enter the port number of the Station to name
Depress [AT/MIC] to enter the Name mode.
4.
5.
6.
Input the name for the related extension by the following function keys.
Press [SAVE] to store the data.
The next extension port will appear ready to program names.
To set a Trunk name -
1. Enter system programming Form 35.
2.
3.
4.
5.
Enter the Trunk number
Depress [AT/MIC] to enter the Name form.
Input the name for the related extension by the following function keys.
Press [SAVE] to store the data.
6. The next trunk will appear ready to program names.
To set a System Speed Dial name
1.
2.
3.
Enter system programming Form 09 or System Speed Dial From the Console
Enter the Speed Dial number
Enter the telephone number
3.
4.
5.
6.
Depress [AT/MIC] twice to enter the Name form
Input the name for the Speed Dial by the following function keys
Press [SAVE] to store the data.
The next Speed dial will appear ready to program
Key Pad
1
2
3
4
5
6
7
8
9
0
*
#
Depress
1 time
Q
A
D
G
J
M
P
T
X
.
-
(
Depress
2 times
Z
B
E
H
K
N
R
U
Y
:
/
)
Depress
3 times
Space
C
F
I
L
O
S
V
Z
&
!
$
Depress
4 Times
1
2
3
4
5
6
7
8
9
0
*
#
DSS23
Cursor Left
DSS24
Cursor Right
Page 138
Appendix B - Programming Cross reference
Ringing Assignment
01-tk-IP
02-tk-IP
20-nn
05-08-01
35-tk-07
35-tk-08
Ringing Assignment - Day Time
Ringing Assignment - Night Time
Define Day-Time Schedule for Automatic Night switch
Hunt Time Assignment
Inward Line (Day) Ringing Type
Inward Line (Night)
DISA
35-tk-04
05-01-04
DISA Transfer
04-(01-08)
05-06-03
05-06-04
05-08-04
05-07-04
05-08-06
05-08-07
05-09-04
05-11-04
05-11-03
05-11-04
05-11-05
05-11-06
05-11-08
10-(01-08)
46-st-03
20-nn
DISA Trunk Day/Night Assignment
DISA Access Delay Time
Console Assignment
VSU Grouping
Polarity Reverse Detection
DISA Transfer Group (Extension or Trunk Group)
DISA Recall Capability-No Dialing
VPC Remind Time for DISA Transferring (No Answer or Busy)
Dialing Wait Time after DISA Service Message
DISA Busy Tone Detection
DISA Passwords
MOH or RBT
DISA Answering Method-VSU Busy
DISA Call Function Access
DISA Re-Check Times to Busy Station/Console
DISA Single Digit Function
Single Digit DISA And Intercom Assignment
DISA Recall Capability (No Answer/Busy)
Define Day-Time Schedule for Automatic Night switching
Voice Service (Optional)
19-IP Voice Service Assignment
Night Transfer
09-nnn-IP
35-tk-03
35-tk-04
System Speed Dial (101-109)
External Call Forward, Speed Dial Assignment
DISA/ECF, Day/Night Assignment
20-nn Define Day-Time Schedule for Automatic Night switch
SK-200 Lodging Package Installation & Programming Page 139
Trunk Pick up
35-tk-05 Pick up (Trunk Specifications)
Trunk Specifications
05-01-05
05-02-07
05-02-08
Busy Remind Cycle Time
Ring On Time
Ring Off Time
Intercom Call Signaling
05-03-03
46-st-03
05-07-01
41-st-01
(Voice/Ring)
Automatic Microphone Switching
Intercom Hunting Capability
Station Group Assignment
Hunt Groups
67-(01-30) Assign Hunt Group Pilot Number
68-(01-30) Assign Stations To Hunting Group-Day
69-(01-30) Assign Stations To Hunting Group-Night
05-08-08 Set Hunting Group Ring Method
Dial Tone Pattern
05-03-07
Single Digit Dialing
05-04-07
10-gp-IP
Intercom Single Digit Capability
Intercom Single Digit Assignment
41-st-01 Group Assignment (Station Specifications)
Direct Station Select
07-gp-IP Flexible Key Group Assignment
41-st-02 Keyphone Flexible Key Group
41-st-03 Keyphone Flexible Shift Key Group
Operator Calls
04-(01-08) Console Groups
05-06-05
44-st-04
05-09-02
Operator Code
Manual Line
Intercom Calls Camp on To busy Console
Page 140
Intercom Dialing Restriction
45-st-01
45-st-05
Intercom Call Limitation
Intercom Calls To Different Station groups
Dial 9/87 Settings
05-04-02 Activate Dial 9 Flag Capability
36-gp-tk
41-st-04
Dial 9 Trunk Group Assignment
Dial 9 Group (Station Specifications)
38-gp-tk Dial 87Trunk Group Assignment
Outgoing Code
05-03-04 Dial 0/9 for outgoing Access
Trunk Specifications
35-tk-01
35-tk-02
Trunk Type
Dialing Signal
05-01-06
05-01-07
Pause Time Duration
DTMF Generation Time
05-02-05 Keyphone Flash Time
05-02-07 Ring On Time
05-02-08 Ring Off Time
05-03-01 Make/Break Ratio
Speed Dial
05-04-06
05-01-06
42-st-01/02
09-nnn-DP
Speed Dial Distribution
Pause Duration for Speed Dial
Register Memory Blocks for Individual Speed Dial
System Speed Dial
05-03-02 Automatic Trunk Search
05-05-03/04 Speed Dial Unrestricted
Auto-Redial
05-03-02
05-02-03
05-05-07
05-05-08
Automatic Trunk Search
Auto-Redial Waiting Time
Auto-Redial Times
Auto-Redial Pause Time
SK-200 Lodging Package Installation & Programming Page 141
Hold & Hold Recall
05-01-01
05-01-02
05-01-03
05-06-01
05-06-02
44-st-02
05-07-04
Hold Recall Time
Exclusive Hold Recall Time
Hold Recall Timeout
Transfer Busy Recall Time
Transfer No Answer Recall Time
Hold Capability
DISA Recall Capability
Busy Remind signal (Off Hook Signaling)
05-01-05 Busy Remind Cycle Time
Message Waiting Level
46-st-02
Override
Set message wait Level
40-st-01 Set Over ride Level
Console Assignment
04-gp-IP Assign Consoles for each group
Flexible Key Group Assignment
07-gp-IP
41-st-02
41-st-03
Flexible Key Group Assignment
Assign Key group to a station
Assign Shift Key group to a station
Trunk Group
36-gp-tk
41-st-04
Trunk Group Assignment
Assign Dial 9 Trunk Group to a Station
Group Assignment (Station Specifications)
41-st-01 (Zone Paging/Pick Up/Station/Single Digit)
Page 142
Toll Restriction
18-gp-tk
41-st-05/06
Toll Plan Programming for Trunks
Toll Plan Assignment for Stations (Day/Night)
Code Assignment
05-03-05 Toll Access Code
51-59-ip
61-66-ip
05-05-03/04
Allow Tables
Restrict Tables
Speed Dial Unrestricted
Forced Account Code
17-nn
40-st-08
Call Limit
Setting Forced Account Codes
Station Allocation of Forced Account Codes
40-st-03
05-04-03
Passwords
Station Call Limit Duration
Call Limit Type
13-01
13-02
05-11-02
13-03
Password for System Programming
Password for DISA
Number of DISA Passwords
Password for Toll Free
Station Lock
40-st-07 Lock / Unlock by Security Code
Busy Out Trunk
37-tk
Time Setting
05-04-04 12/24 Hours Clock
11-IP Date and Time Setting
20-nn Define Day-Time Schedule
System Alarm
12-nn
44-st-01
44-st-08
System Alarm Clock
System Alarm Capability
System/User Alarm Signaling
SK-200 Lodging Package Installation & Programming Page 143
Morning Call
05-05-01
19-IP
Morning Call Signaling
Voice Service Assignment
Flexible Station Numbering
41-st-07
05-03-06
43-cn-01
Show the Port Number (cn)(csn)
Assign Station Number Digit Length
Enter a Station Number for the port
SLT Parameters
05-02-01
05-02-02
05-02-04
05-02-06
05-04-05
05-04-08
05-06-07
05-07-02
05-08-03
05-08-05
43-st-04
44-st-02
44-st-03
45-st-02
Paging
SLT Dial Tone Timeout
SLT Interdigit Timeout
SLT Release Time
SLT Hold Signal
SLT Flash Delay Time (SK-200)
SLT Message Waiting Type
Affirmative SLT Hookswitch (Hold) Capability
SLT Calling Proof Capability
SLT Busy Remind Tone Flag
SLT Programming Digit
Analogue Extension allowed on Hybrid port
Hold Feature Enable
Call Split Feature Enable
Dual Port Capability
40-st-05
40-st-06
41-st-01
05-06-01
05-01-03
05-08-06
05-08-07
Access to Paging
Receive all Page Signal
Station / Paging Group Assignment
Call Split
44-st-03 Allow/Disallow Call Split
Call Transfer
Transfer Recall Timeout (Busy)
Transfer Recall Timeout (No Answer)
VPC Remind Time for DISA Transferring (NoAnswer or Busy)
Waiting Dialing Time after DISA Service Message
Page 144
Call Forward No Answer Transfer Time
05-01-08 Set Timer for Call Forward No Answer
Hot Line
47-nnnn Allocate Hot Line to Station
09-nnnn-IP System Speed Dial
Doorphone & Doorswitch
03-nn-IP
05-03-08
05-11-07
05-12-04
06-IP
46-st-06
DSS Console
Door PhoneRing Assignment
Door Phone Ring Frequency
Door Phone Ring Time
Door Relay Unlock Time
Door Relay Assignment
Door Unlock Access
08-gp-IP
41-st-07
43-cn-01
43-cn-03
Flexible DSS Key Group Assignment
Port Number for DSS Console
Assign Station Number for DSS Console
DSS Key Group (SK-200)
Fax Monitor
05-04-05 Fax Monitoring Capability
Headset
44-st-05 Headset Capability
User Function [SPK][7][7][5]
Loud Bell (Trunk)
06-IP=04
35-tk-06
Assign the Relay for Trunk Loud Bell
Assign the trunk to activate Relay
Loud Bell (Station)
06-IP=05
40-st-04
Assign the Relay for Station Loud Bell
Assign the Station to activate Relay
External Music Source
06-IP=01
05-08-08
Relay Assignment
Music Source Selection (BX8
SK-200 Lodging Package Installation & Programming Page 145
Paging (External Paging)
06-IP=10-12 Relay Assignment
SMDR
14-01-(01-08) Station Message Detail Recording
05-07-06 SMDR Digit Masking
Meter Pulse Detection
05-05-02
05-07-07
Meter Pulse Detection
Meter Pulse Detection Delay Time
Voice Processing Service
19-IP Voice Service Assignment
05-05-01 Morning Call Signaling
System Reset
25- 1 Reset System Programming Data To Default Except Speed Dials.
25- 2 Reset All System Programming Data To Default.
25- 3 Restrict All Stations from Using Hold and Call Split.
25- 4 Restrict All Stations from Using Barge in And Monitor.
Page 146