INSTALLATION &

OPERATION GUIDE

920-087-04 (8-05)

PTAC

PACKAGED TERMINAL

AIR CONDITIONERS

& HEAT PUMPS

Standard Control

Remote Thermostat

Seacoast Protected

920-087-04 (8-05)

Tableof Contents

Model Number Code ..........................................................................................................................................................................................3

Installation Recommendations ..........................................................................................................................................................................4

Friedrich Digital Control Features .................................................................................................................................................................5-6

Drain Kit Installation ........................................................................................................................................................................................7-8

Wall Sleeve Installation .................................................................................................................................................................................9-10

Deep Wall Installation ......................................................................................................................................................................................11

Standard Grille Installation ..............................................................................................................................................................................12

Electrical Rating Tables ...................................................................................................................................................................................13

Power Cord Information ...................................................................................................................................................................................13

Installation Checklist ........................................................................................................................................................................................14

Chassis Installation .....................................................................................................................................................................................14-15

Digital Control User Input Configuration .........................................................................................................................................................16

Operation ..........................................................................................................................................................................................................17

Remote Thermostat and Low Voltage Control Connections .........................................................................................................................18

Desk Control Terminals ...................................................................................................................................................................................19

Auxiliary Fan Control ........................................................................................................................................................................................19

Fresh Air Vent Control ......................................................................................................................................................................................19

Air Discharge Grille ..........................................................................................................................................................................................19

Appendix A: Electrical Wiring for 265 V Models ............................................................................................................................................21

Routine Maintenance .......................................................................................................................................................................................22

Basic Troubleshooting Techniques .................................................................................................................................................................23

Digital Control Diagnostics and Test Mode ....................................................................................................................................................24

Accessories ................................................................................................................................................................................................25-26

Warranty ...........................................................................................................................................................................................................27

Typical Unit Components

Frontcover

Chassis jrille

920-087-04 (8-05)

Thank you for your decision to purchase the newly designed Friedrich Packaged Terminal Air Conditioner (PTAC). We are confident that you will find this unit a quiet and efficient example of Friedrich reliability.

This Installation and Operation Manual has been designed to insure maximum satisfaction in the performance of your unit.

For years of trouble-free service, please follow the installation instructions closely. We cannot overemphasize the importance of proper installation. We have added new information to the basic instructions to help you achieve success.

Remember,

proper installation

is not difficult but it is essential.

I

Series

PD = Friedrich Digital PTAC

System

X = Accessory

E = Cooling with orwithout electric heat

H = Heat Pump with Auxiliary Heat

Nominal Cooling Capacity

07 = 7,000 Btuh

09 = 9,000 Btuh

12 = 12,000 Btuh

15 = 15,000 Btuh

Model Number Code

PDH 07K 3 S A 1

I_

t Engineering Digit

I Design Series

Options

S = Standard

C = Seacoast Protection

Nominal Heater Size

(@ 230V or 265V)

0 = No Heater

2 = 2.5 KW

3 = 3.4 KW

5 = 5.0 KW*

* 5.0 kw only available on 12000and 15000

Btu/h models

I

Voltage

K = 230/208V - 1 Ph, - 60 Hz.

R = 265V-1 Ph.-60Hz,

I

I

I

I

Please read this manual thoroughly prior to equipment installation or operation.

It is the installer's responsibility to properly apply and install the equipment.

Installation must be in conformance with the NFPA 70-2002 National

Electric Code or current edition and Uniform Mechanical Code current edition and applicable local or national codes.

920-087-04 (8-05)

PTACInstallation Recommendations

For proper PTACunit performance and maximum operating life please refer to the minimum installation clearances below:

FigureI

PTAC units should be installed no closer than 12" apart when two units are side by side. If three or more PTAC units are to operate next to one another allow a minimum of 36" between units.

Also, a vertical clearance of 60" should be maintained between units installed.

VIEW: OUTSIDE

BUILDING ELEVATION

THREE OR MORE PTACs

A.DJACENT 36" MINIMUM

BETWEEN PTACs

12"

Figure2

For PTACs on the ground floor or anytime obstructions are present, use the following guidelines:

For minor obstructions such as lamp poles or small shrubbery a clearance of 12" from the outdoor louver should be maintained.

For major obstructions such as a solid fence, wall or other heat rejecting device like a condensing unit, a minimum distance of 36" should be kept.

PTAC

?\

J \

TYP. BUILDING ( PLAN VIEW )

7

PTAC / PTAC

, i_:,._

J

_...........................

OBSTRUCTIONS _

36" MIMUMUM MAJOR _'_

OBSTRUCTIONS

POLE_j.J---

/_-- JJ

_

3,_5 ¢_

._

/ .....',J

1 J

I

_ FENCE OR WALL

CONDENSING UNIT

The above suggestions are for reference only and do not represent all possible installations. Please contact the factory for information regarding affects of other installation arrangements.

By following these simple recommendations you can be confident that your Ffiedrich PTAC will provide years of worry free operation.

920-087-04 (8-05)

FriedrichDigital Control Features

The new Friedrich digital PTAC has state of the art features to improve guest comfort, indoor air quality and conserve energy.

Through the use of specifically designed control software for the PTAC industry Ffiedfich has accomplished what other Manufacturer's have only attempted - a quiet, dependable, affordable and easy to use PTAC.

Below is a list of standard features on every Friedrich PTAC and their benefit to the owner.

Digital Temperature

Readout

One-Touch Operation

Individual Mode and

Fan Control Buttons

Quiet Start/Stop

Fan Delay

Remote Thermostat

Operation

Wireless Remote

Control Ready

Internal Diagnostic

Program

Service Error Code

Storage

Bydigitallymonitoringdesiredroomtemperaturethe room iscontrolledmorepreciselythanconventionalsystems.The large,easy to readLEDdisplaycanshoweitherset-pointor actualroomtemperatureasselectedby owner.

Whenthe unit is poweredoff the unit can be returneddirectlyto heatingor coolingmodeby pressingthe 'Heat'or 'Coot'buttons withouttheconfusingpowerup sequenceof somecontrols.One-touchcontroltakesguessworkoutofunitcontroldeliveringamore enjoyableexperienceandeliminatingfront-deskcalls.

Byhavingseparatecontrolbuttonsandindicatorsforbothfan andmodesettingsthe Friedrichdigitalcontroleliminatesthe confusionof previousdigitalPTACs.Theaccuratetemperaturesettingprovidesgreaterguestcomfortthanothersystems.

Thefanstartandstopdelayspreventabruptchangesin roomacousticsduetothe compressorenergizingor stoppingimmediately.

for"free cooling"byutilizingthe alreadycoolindoorcoil to its maximumcapacitybyrunningfor30 secondsafterthe compressor.

Someapplicationsrequirethe use of a wall mountedthermostat.All newFriedrichPTACsmay be switchedfrom unit controlto remotethermostatcontroleasilywithoutthe needto ordera specialmodelor accessorykit,

Guestscanadjustthe temperatureandmodeofthe unitthroughthe used an optionalhandheldwirelessremote,improvingguest comfortandrelaxation.

problems,Theinternaldiagnosticprogramsavespropertiesvaluabletimewhen diagnosingrunningproblems.

Theself diagnosisprogramwilI alsostoreerrorcodesin memoryif certainconditionsoccurand correctthemselvessuch asextremehighor low operatingconditionsor activationof the roomfreezeprotectionfeature,Storingerrorcodescan helpproperties determineif the unitfacedobscureconditionsor if an erroroccurredandcorrecteditself.

Constant Comfort

Room Monitoring

Theon-boardprocessormonitorstime betweendemandcycles(heator cool)andwilIcyclethefan every9 minutesto samplethe roomconditionanddetermineif the desiredconditionsaremet.Thisallowsthe roomto havesimilarbenefitsto a remotemounted statwithoutthe complicationor costofa wailmountedthermostat.

Electronic Temperature

Limiting

Bylimitingthe operatingrangethe propertycansaveenergybyeliminating"maxcoot"or "maxheat"situationscommonwith older uncontrolledsystems.Thenewelectroniccontrolallowsownerstoset operatingrangesforbothheatingandcoolingindependently of oneanother.

RoomFreeze

Protection

Whenthe PTACsensesthatthe indoorroomtemperaturehasfallento 40° Fthe unitwill cycleon highfan andthe electricstripheat to raisethe roomtemperatureto 46°F thencycleoff again.Thisfeatureworks regardlessof the modeselectedandcan beturned off. Thecontrolwill alsostorethe RoomFreezecyclein the servicecodememoryfor retrievalata laterdate.Thisfeatureensures

thatunoccupiedroomsdo notreachfreezinglevelswheredamagecan occurto plumbingandfixtures.

RandomCompressor

Restart

Multiplecompressorsstartingat oncecan oftencauseelectricaloverloadsand prematureunitfailure.The randomrestartdelay eliminatesmultipleunitsfrom startingat oncefollowinga poweroutageor initialpowerup, The compressordelaywill rangefrom

180to 240seconds.

DigitalDefrost

Thermostat

The newFriedrichPTACusesa digitalthermostatto accuratelymonitorthe outdoorcoil conditionsto allowthe heatpumpto run wheneverconditionsarecorrect,Runningthe PTACin heatpump modesaveenergyandreducesoperatingcosts.The digital thermostatallowsmaximizationof heatpumpruntime.

920-087-04 (8-05)

FriedrichDigital ControlFeaturesContinued

Instant Heat

Heat Pump Mode

Even Heat Monitoring

thenreturntoheatpumpmode.Thisensuresthattheroomis broughtup totemperaturequicklywithouttheusualdelayassociatedwith heatpumpunits.

Thedigitalcontrolmonitorsindoorconditionstoensurethattheroomtemperatureiswithinfivedegreesofthe setpoint.If necessarytheunitwill cyclethe electricheatto maintainthetemperature.Thisfeatureensuresguestcomfortbydeliveringthe heating

Fan Cycle Control

Indoor Coil Frost Sensor

Ultra-Quiet Air System

Theownermaychoosebetweenfan cyclingorfan continuousmodebasedon propertypreference.(Note:Evenheatmonitoringandquietstart/stopfan delayonlyoperatein fan cyclemode)Fancontinuousmodeisusedtokeepconstantairflowcirculationin the roomduringatItimes theunit is 'ON'.Fancyclewill conserveenergybyonlyoperatingthe fanwhile the compressor or electricheateris operating.

Emergency Heat Override

Desk Control Ready

Inthe eventof a compressorfailurein heatpumpmodethe compressormaybe lockedout to provideheatthroughthe resistanceheater.Thisfeatureensuresthatevenin the unlikelyeventof a compressorfailurethe roomtemperaturecan be maintaineduntilthecompressorcanbe serviced.

All FriedrichdigitalPTACshavelow voltageterminalsreadyto connecta desk controlenergymanagementsystem.Controllingthe unitfroma remotelocationlikethe frontdeskcan reduceenergyusageand requiresno additionalaccessoriesat the

PTAC.

Thefrostsensorprotectsthe compressorfromdamagein the eventthatairflowis reducedor lowoutdoortemperaturescause the indoorcoilto freeze.Whenthe indoorcoil reaches30°F the compressoris diabtedandthe fan continuesto operatebased ondemand,Oncethe coiltemperaturereturnsto 45°F the compressorreturnsto operation.

The newFriedrichPDseriesunitsfeaturea indoorfan systemdesignthat reducessoundlevelswithoutloweringairflowand preventingproperaircirculation,

High Efficiency

Single Motor

Rotary Compressor

Auxiliary Fan Ready

TheFriedrichPTACbenefitsqualitycomponentsandextensivedevelopmenttoensureaquiet,efficientanddependableunit.

Friedrich'ssingIe-motordesignallowsfor enhancedoutdoorairflowandsimplifiesthe unitdesignwithoutthe needfor redundantcomponents.

Highefficiencyrotarycompressorsareusedon allFriedrichPTACsto maximizedurabilityandefficiency.

TheFriedrichPTACfeaturesa 24VAC terminalfor connectionto an auxiliaryfan thatmay be usedto transferair to adjoining rooms.Auxiliaryfanscan provideconditioningto multipleroomswithoutthe requirementof multiplePTACunits.

Aluminum Endplates

Seacoast Protection

Top Mounted Antimicrobial Air Filters

Filtered Fresh Air Intake

All FriedrichPTACsarebuiltwith .04"endplatesmadefrom aluminumasopposedto steel.Theendplatesaretypicallythe most susceptibleareaforcorrosionandaluminumisfar moreresistantto corrosionthanevencoatedsteel.

OptionalSeacoastprotectionis availableto protectthe outdoorcoilfrom harshenvironments.TheFriedrichSeacoastprocess

includesdippingthe entireoutdoorcoilin a 7-stepcoatingprocessthatprovidessuperiorprotectionto onlycoatingthefins of thecoil.

All FriedrichPTACreturnair filtersfeaturean anti-microbialelementthathas provento preventmoldand bacterialgrowthin laboratorytesting.PDXFTreplacementfilter kitsfeaturethe sameanti-microbialagent.All filters arewashableandreusable andare easilyaccessedfrom the topof the unitwithoutthe removalof thefrontcover.

FriedrichPTACunitsarecapabieof introducingup to70 CFMof outsideair intothe conditionedspace.Theoutdoorair passes throughawashablemeshfilterto preventdebrisfromenteringthe airstream.

920-087-04 (8-05)

Installation Instructions PXDRIO Drain Kit

NOTE: Determine whether drain will be located within the wall, on the indoor side, or will drain to the exterior of the building. Follow appropriate instructions below depending on your particular type of installation.

Internal Drain (optional for new construction)

NOTE: If installing an internal drain, you MUST install a drain kit on the wall sleeve before the wall sleeve is installed.

5,

,

,

,

,

,

Refer to Figure 3 below and locate the drain within the

"Primary" area for best drainage. Maintain at least a 1!2" clearance from the embossed area.

Using the mounting plate with the 1/2" hole as a template, mark and drill two, 3/16" mounting holes and a 1/2" drain hole.

Remove the backing from the gasket and mount it on the flat side of the mounting plate. (See Figure 4.) Insert the drain tube through the hole in the gasket and mounting plate so the tube flange will be against the wall sleeve.

Position the assembly beneath the drilled holes and secure it with #10-24 x 1/2" machine screws and lock nuts provided. Seal the tops of the screws with silicone caulking.

Use 1/2" I.D. copper tube, PVC pipe, or vinyl hose (obtained locally)to connect the internal drain tube to the drain system in the building.

Referring to Detail A on page 6, locate and assemble the

(2) two cover plates and gaskets over the drain holes at the rear of the wall sleeve. Attach them with the #10 sheet metal screws provided. Make certain that the four overflow slots at the rear of the wall sleeve are not blocked (See drawing of the back of the sleeve on page 6).

If a deep wall extension (PXWE) is used, after installing the field supplied flashing, caulk as required. Be sure to caulk around the flashing and the wall sleeve where the hole was drilled for the drain tube.

Figure3

Drain Kit Locationand Installation

Primary area - no foam insulation

If the drain must be located in the secondary area, the foam insulation must be cut away and removed to allow access to the drain.

Gasket

Mounting plate -_._/

• Nut_Jl'l

Drain tube _

4

I Fq---Tq

I I I t

I

\\

\\

_._

7.6 cm

ExtemalDrain(for new constructionor unit replacement)

When using an external drain system, the condensate is removed through either of two drain holes on the back of the wall sleeve.

Select the drain hole which best meets your drainage situation and install the drain kit. Seal off the other with a cover plate.

Drain Tube Installation

1.

Peel the backing tape off the gaskets and apply the sticky side to one cover plate and one mounting plate as shown in Details A and B.

2.

Place the drain tube throughthe gasket and the mounting plate with the flange toward the wall sleeve.

Attach the drain tube assembly to one of the two drain holes at the rear of the wall sleeve. The large flange on the mounting plate is positioned atthe bottom of the sleeve facing toward the sleeve, Detail B. When the drain tube is positioned at the desired angle, tighten the screws.

NOTE: If the wall sleeve has not been installed, the drain tube must be rotated to a horizontal position until after the sleeve is installed. Tighten the mounting plate screws when the tube is in the proper position. Make certain that the four overflow slots at the rear of the wall sleeve are not blocked. (See the drawing below.)

Cover Plate Installation

4.

Mount the foam gasket to the cover plate. Using two

#10 x 1!2" sheet metal screws (provided), attach the cover plate to the remaining drain hole. Make certain the large flange on the plate is positioned at the bottom of the sleeve.

5.

Discard the additional cover plate, gasket, machine screws, and Iocknuts.

QUANTITY

2

1

1

3

4

2

2

DESCRIPTION

COVER PLATES

MOUNTING PLATE

DRAIN TUBE

MOUNTING PLATE GASKETS

#10 X 1/2" MOUNTING SCREWS

10-24 X 1/2" MACH. SCREWS

LOCKNUTS

Figure4

Drain Kit Installation

-Foam gasket

Mounting plate

DETAIL A

/

I V2" O.D. tube

Foam gasket

Mounting plate

_

# 10 sheet metal screws

DETAI

L B

NOTES:

The large flange on the mounting plate is positioned at the bottom of the sleeve facing toward the sleeve. The drain tube must be rotated to a horizontal position to allow for the wall sleeve to be installed into the wall. Once the wall sleeve is installed, return the drain tube to a downward angle.

920-087-04 (8-05)

Wall Sleeve Installation Instructions(PDXWS)

NOTE: Insure that the unit is only installed in a wall structurally adequate to support the unit includingthe sleeve, chassis and accessories.

If the sleeve projects more than 8" into the room, a subbase or other means of support MUST be used. Please read these instructions completely before attempting installation.

Figure5

Typical Wall Sleeve Installation

J

Electrical receptacle

16W'

Lintel to support masonry

10 _

(25.4 cm) m_

Electrical

Wall opening

Wall sleeve --

insulation--

Smooth side of screw clip facing into room

Note: All 230/208V units are manufactured with a 60" power cord. The receptacle

locations above must be followed to ensure proper connections.

For Deep Wall Installation See Section II

The following instructions apply ONLY to walls less than

13 1/4" in depth.

1.

From inside the building, position the wall sleeve in the opening and push it through the wall so it protrudes at least

1/4" on the outside, note Figure 5.

,

Position the wall sleeve with a slight tilt towards the outside to facilitate condensate drainage. It should be level side-toside and the front should be 1!4 bubble higher than the back.

DO NOT allow any pitch toward the inside.

Electrical shock hazard.

Turn electric power OFF at the fuse box or service panel before making any electrical connections and ensure a proper ground connection is made before connecting line voltage. Failure to do so can result in property damage, personal injury and/or death.

10

920-087-04 (8-05)

Figure6

Dimensions

T

B

(6.4 cm)

rain.

Wall

Dimension*

No Accessories

With

With

Su bbase

Lateral Duct

A

Allow

for wall

finishing

(Minimum)

¼"

(6.4 mm)*

1¾"

(4.5 cm)

¾"

(1.9 cm)

Min.

¼"

(6.4 mm)

3W'

(8.9cm)

¼"

(6.4 mm)

B

Allow for floor finishing

Max

---

5"

(12.7cm)

---

* If more than one accessory is to be used, use the maximum dimension.

If the wall thickness is more than 13¾" (35cm) -

(A + ¼" [6.4 mm]), a sleeve extension must be used.

Drill two 3/16" holes through each side of the sleeve approximately 4" from top and 4" from bottom of sleeve.

Screw four #10 x 1" screws (included) or appropriate fasteners for your installation, through the holes in the sides of the wall sleeve.

,

Apply sealant around the wall sleeve where it projects through the inside and outside wall surfaces.

Apply the sealant to the screw heads or the tops of the fasteners used in Step #3.

NOTE: When sealing the sleeve on the outside of the building, be careful NOT to let the sealant block the two condensate drain holes or the four overflow slots at the bottom flange of the sleeve.

Figure7

Lintel Installation

Mainstuds

Jack studs

Main

If the chassis and exterior grille are to be installed later, leave the weatherboard and center support in place, otherwise remove and dispose of them.

Provide a support lintel if the wall sleeve is installed in a concrete or masonry wall. (See Figure 7.)

Lintel

Mounting screw holes

No holes in bottom of wall sleeve unless drain kit is used

NOTE: Construct wall opening to comply with all applicable building codes.

920-087-04 (8-05)

Section II - Deep Wall Installation (PXWE)

If the wall is thicker than allowed in the notes in Figure 6, a sheet metal wall sleeve extension and flashing MUST be used.

Installation Instructions for the PXWE - 4" Wall

Sleeve Extension

The following points MUST be considered when installing a wall sleeve extension:

1 Provision must be made to direct excess condensate from the back of the wall sleeve into the extension then outside the building or to a drainage system.

2. Air baffles must be mounted to properly direct air flow to and from the condenser.

3. Thewall sleeve extension design must allow for the proper mounting of the grille.

4. Caulking is required at all sites where condensate or external water could potentially infiltrate into the building.

5. Fabricate and install metal flashing in wall to serve as a drip panel. Refer to drawing for more information.

6. Condensate notches and overflow slots must be kept clear of sealant and gaskets so condensate can flow freely into the wall sleeve extension.

NOTE: Improper fabrication or installation of a wall sleeve extension will impair PTAC performance.

Extension Installation

Secure the wall sleeve extension to the wall sleeve before installing it in the wall. Refer to Figure 8 for a guide for fabrication of a condensate drip panel. The panel MUST extend the full depth of the wall sleeve and the wall sleeve extension.

Pay particular care in sealing and caulking the panel where it makescontact with thewall sleeve (see Figure8). After installation in the wall, secure with fasteners through the sides. Use a good grade of silicone sealant around the sleeve extension. Seal all exposed screw heads. When the installation is complete, the outside grille should be attached to the wall sleeve extension.

Figure8

Wall SleeveExtensionSealant Locations

_')

IMPORTANT NOTE: The silicone bead MUST extend 3"

J

up the side of the two flanges to prevent condensate

/

from leaking.

_!'

Wall Sleeve

_ION__

_X'e'n"si'on

r_ear _an_

I Wall

Sleeve

I

_._

r,_n/._

_.llf,[/'_)

_lll_i='_"

• l

s

w=.

_l .....

_

Silicone

Bead 7-_

_.

"_,

Wall Sleeve

Extension

Outside Edge

Insulation

Sealant

I Drip Panel

Sealant around perimeter

L

Width of Wall

Drip

Edge

Notches (4)

Wall Sleeve Extension, 42" X 16" Frame, 20 gauge minimum, painted or aluminium i Sealant inside

(4) bottom corners

12

920-087-04 (8-05)

Installation InstructionsModel PXGAStandard Grille

1. Remove the center support and weatherboard if still installed in the sleeve.

2. Insert six plastic grommets into the grille openings from the outside of the grille as shown in Figure 9.

3. Insert two #8 x 3/8" sheet metal screws (provided) in the top two outside edge plastic grommets, and tighten them halfway into the grommets.

4. CAUTION: Bodily injury can be caused by grilles falling from a building during installation. It is recommended that a safety line be attached to the grille and an anchor point inside the buildina durina installation.

5. Grasp the grille by the attached plastic handles. Position it with the condensate drain knockouts facing down. From inside the building, maneuver the grille through the wall sleeve and pull toward you until the screw heads are inserted into the keyhole slots at the top of the wall sleeve.

Tighten the two screws completely.

6. Insert the remaining screws into the remaining holes and tighten securely.

Figure9

Standard Grille

Quantity

1

6

6

Description

Stamped Aluminum Grille

Plastic Grommets

#8 x 3/8"Sheet Metal Screws

Wall sleeve

-Weatherboard

-Center support

!

Plastichandles Plastic grommets

920-087-04 (8-05)

A. Electrical RatingTables

All 230/208 volt units are equippedwith powercords.See AppendixBon page19 forwiringinstructionson265V units.

NOTE: Use Copper Conductors ONLY. Wire sizes are per NEC, check local codes for overseas applications.

Table 1

AMPS

250 V Receptacles

15

and Fuse Types

20* 30

WIRE SIZE

RECEPTACLE

(_ @

TIME-DELAY TYPE FUSE

(or HACR circuit breaker)

15 20

HACR - Heating, Air Conditioning, Refrigeration

* May be used for 15 Amp applications if fused for 15Amp

NOTE: 265 volt units are hard wired.

@

30

Table

2

Recommended

NAMEPLATE / MAXIMUM

CIRCUIT BREAKER

SIZE

15

20

30

branch

circu#

wire sizes*

AWG WIRE SIZE**

14

12

10

AWG -American Wire Gauge

* Single circuit from main box

** Based on copper wire, single insulated conductor at 60°C

ELECTRIC SHOCK HAZARD! rum dfelectric powerbeforeserviceorinstallation.

All electricalconnectionsandwiring MUSTbe installedbya qualifiedelectricianand conformto the NationalBectricatCode and all local codeswhich havejurisdiction.

Failureto doso can resultinpropertydamage,personalinjuryand/ordeath.

FUSE/CIRCUIT

BREAKER

GROUNDING

RECEPTACLE

WIRE SIZING

Use ONLY wiring size recommended for single outlet branch circuit.

Use ONLY type and size fuse or HACR circuit breaker indicated on unit's rating plate.

Proper current protection to the unit is the responsibility of the owner.

NOTE: A time delay fuse is provided with 265V units.

Unit MUST be grounded from branch circuit through service cord to unit, or through separate ground wire provided on permanently connected units. Be sure that branch circuit or general purpose outlet is grounded.

The field supplied outlet must match plug on service cord and be within reach of service cord. Refer to Table 1 for proper receptacle and fuse type. Do NOT alter the service cord or plug. Do NOT use an extension cord.

The field supplied outlet must match plug on service cord and be within reach of service cord. Refer to Table 1 for proper receptacle and fuse type. Do NOT alter the service cord or plug. Do NOT use an extension cord.

Use recommended wire size given in Table

2 and install a single branch circuit. All wiring must comply with local and national codes.

NOTE: Use copper conductors only.

B. PowerCordInformation(230/208V modelsonly)

All Friedrich230/208V PTACunits are shippedfrom thefactory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device meets the UL and NEC requirementsfor cord connected air conditionerseffective August 2004.

To test your power supply cord:

1. Plug power supply cord into a grounded 3 prong outlet.

2. Press RESET.

3. Press TEST (listenfor click; Reset button trips and pops out).

4. Press and release RESET (listen for click; Reset button latches and remains in). The power supply cord is ready for operation.

NOTE: The LCDI device is not intended to be used as a switch.

Once plugged in the unit will operate normally without the need to resetthe LCDI device.If the LCDIdevice trips and requiresresetting the cause of the trip should be identified prior to further use of the

PTAC.

If the device fails to trip when tested or if the power supply cord is damaged itmust be replacedwith a newsupply cord obtained from the product manufacturer,and must not be repaired.

FigurelOb

30A I.CDI Device

4 ,t ,i

FigurelOa

15/20A I.CDI Device

2"

1

13

Installation Checklist

[] Inspect all components and accessories for damage before and after installation.

[] Remove the cardboard wall sleeve support and grille weatherboard.

[] Check for proper wall sleeve installation in accordance with the wall sleeve installation instructions.

[] Check for a subbase kit or other means of structural support which is required for ALL installations projecting more than 8" into room.

[] Install the recommended Condensate Drain Kits for complete condensate removal.

920-087-04 (8-05)

[] Ensure that the chassis is installed in a 16" high x 42" wide wall sleeve that is no deeper than 13 3/4". A baffle kit is required if the sleeve exceeds that depth.

[] Ensure that drapes, bed, bedspread, furniture, etc. DO

NOT block either return or discharge air grilles.

[] Inspect the condenser air inlet and outlet for any obstructions (shrubbery, etc.)

[] Ensure that'reset' button is pressed on LCD device (only on cord connected models)

Section III - ChassisInstallation

Checkto be surethe wall sleeve,extension(if used),grille,anddrain kit are installedproperlybeforechas.,isinstallation.

1. Removetheweatherboardand centersupportfrom the sleeve

(if still in place). Be sure an outdoor grille is attached.

NOTE: To avoid breaking the door or hinge pins, do not apply excessive force when installing

®

Pins

Wall sleeve

"

Control

Door

--Weatherboard i

J

Front Panel

Center support

IMPORTANT:Usea wall sleeveadapterkit (PXSE)if installing a P-Series chassis in a T-Series sleeve.

3. Remove the two chassis shipping brackets from the ends of the shipping pallet.

®

Compressor

Suffocation hazard

Keep bag away from babies and children.

Do NOT use in cribs, beds or playpens.

Destroy immediately after opening. This bag is NOT a toy.

Failure to do so can result in personal injury and/or death

14

2. Remove the front cover contained in a protective plastic bag from chassis. Remove the bag and dispose of it properly.

If the control door is not installed, follow these steps:

From the front of the cover, slide the right control door pin into the hole on the right side of the front cover. Slide the left door pin into the hole on the left side of the front cover opening and snap it into place.

Chassis shipping bracket

Shipping pallet

IMPORTANT: When installing a Friedrich P-Series PTAC intoan existing sleeve, it is important to ensure that the unit is installed completely. Inspection of the air seal between the condenser air baffles and around the indoor mounting flange is recommended.

In some cases additional gaskets or baffling may be required.

4. Center the chassis in the pre-installed sleeve and carefully push the chassis untilthe chassis flange and gasket contact the sleeve flange.

®

920-087-04 (8-05) them into the quick nuts located on the chassis to secure the cover. If the unit has been placed such that there is no room to insert the thumbscrews from the bottom, request a

Side Mounting kit (Part No. PXSM) from Friedrich. Locate the service cord or conduit in the notch at the bottom right of the front cover.

®

Wall sleeve j Wall sleeve flange

Chassis flange and gasket

NOTE: If the unit is mounted flush to the floor, the service cord

MUST be rerouted at the bottom of the front cover on the side closest to the receptacle. A notch MUST be made in the front cover side where the cord exits the unit. It is the responsibility of the installer to create an exit notch. See diagram 8 for suggested opening size and placement.

®

Screw clips

7. If the filters are not already installed in tracks in the plastic cover, slide them into place.

8. Plug the cord (if applicable)into the appropriate receptacle.

Extra cord may be coiled inside the front cover behind the return air grille. Restore power to the unit.

® mounting screw

Chassis flange

5. Locate the four #10 x 1"chassis mounting screws. Tighten the screws intothe clips - adjacent to the alignment dimples on the mounting brackets on the wall sleeve flange (two per side).

6. Install the front cover assembly (including the discharge grille) by placing the top of the cover onto the 90 ° angle bracket along the top of the chassis. Rotate the bottom into place and insert the included thumb screws into the slots located at the bottom back corners of the cover. Tighten

To remove the front cover, remove the thumbscrews at the bottom back corners of the cover (or sides).

Pull the bottom end forward and lift it up to clear the

L bracket across the top of the chassis,

®

Not to scale

If a remote thermostat is to be installed, proceedto page 18, Step 1, Fora 265 V unit, proceedto AppendixA,Step 1.

15

920-087-04 (8-05)

Digital Control User Input Configuration

The adjustable control dip switches are located at the lower left hand portion of the digital Smart Center. The inputs are only visible and accessible with the front cover removed from the PTAC.

Dip Switch Setting

1) Electronic Temperature Limiting - Switches 1-4

The digital control is set from the factory to allow a temperature range between 60°F and 90°F in both heating and cooling mode. Dip Switches 1-4 can be used to set high and low limits for either heating or cooling or both.

From the factory all four switches are in the up 'ON' position.

The charts to the right show the available electronic limiting ranges.

Heating Range Switches 1 & 2

Temperature

Range

Low

60

60

60

60

High

90

87

84

81

1

On

Off

Off

On

Dip

Switch

2

On

On

Off

Off

2) Fan Cycle Control - Switch 5

All PTACs are shipped from the factory with Dip Switch 5 in the

'OFF' position to cycle the fan only when there is a demand for the compressor or heater. As an option the fan may be set to

'continuous' mode by switching Dip Switch 5 to 'ON' position to run the fan continuously while the unit is powered on.

To ensure that the room temperature is maintained evenly while in fan cycle mode the Even Temp Load Anticipation feature is enabled. Quiet Fan Belay is also enabled in fan cycle mode to lessen the acoustical change between compressor start up and shut off by running the fan for 5 seconds before each demand cycle, and 30 seconds after cooling or 15 seconds after heating cycles.

Cooling Range Switches 3 & 4

Ternperatu re

Range

Low

60

63

66

69

High

90

90

90

90

3

On

On

Off

Off

Dip

Switch

4

On

Off

Off

On

Figure11

Factory Dip Switch Configuration

3) Room Freeze Protection - Switch 6

Units are shipped from the factory with the room freeze protection disabled. Room Freeze Protection can be switched on at the owner's preference by moving Dip Switch 6 to 'ON'. This feature will monitor the indoor room conditions and in the event that the room falls below 40°F the unit will cycle on high fan with the electric heater. This occurs regardless of mode.

12345678

4) Emergency Heat Override - Switch 7

In the unlikely event of a compressor failure a heat pump unit may be switched to operate in only the electric heat mode until repairs can be made. Moving Dip Switch 7 to 'ON'.

Note: PTAC must be disconnected from power supply

when making any configuration changes.

16

920-087-04 (8-05)

Digital ControlOperation

TemperatureDisplay

The Ffiedfich digital PTAC is shipped from the factory to display the desired room temperature on the LED readout.

The unit can be configured to display the room temperature by simultaneously pressing the 'Cool' and 'High Fan' buttons for three seconds the display will show an 'F,"for one seconds to acknowledge the change. The unit will display the setpoint whenever the 'Temp' A or v buttons are pressed and then switch back to room temperature.

To revert back to displaying the setpoint only press the 'Ceor and

'LowFan' buttons for three seconds simultaneously, the unit will display an'S' for one seconds to acknowledge the change.

°Fvs. °C Display

The unit is factory configured to display all temperatures in degrees Fahrenheit (°F). To switch to degrees Celsius press the 'Fan Only' and 'Low Fan' buttons simultaneously for three seconds. The display will show a 'C' as acknowledgement of the change.

To revert back to oFpress the 'Fan Only' and 'Low Fan' buttons simultaneously for three seconds. The display will show an 'F' as acknowledgement of the change.

Cooling Mode

Pressing the 'Cool' button while the unit is in any mode, including off, will put the unit into cooling mode. Adjust the temperature readout to the desired room temperature and the unit will cycle the compressor on and off to maintain a comfortable room. The compressor will come on anytime that the room temperature is 1.8°F above the desired temperature. The fan operation is dependent on the fan mode selected, either continuous or cycling.

See page 16 for fan cycle control.

Heating Mode

Pressing the 'Heat' button while the unit is in any mode, including off, will put the unit into heating mode.

Heat Pump Models (PDH)

When the 'Heat' button is pressed initially the unit will energize the electric resistance heat to quickly bring the room to the set temperature. When the desired room temperature falls

1.8°F below the desired set temperature the unit will cycle the compressor on and operate as a heat pump to maintain the room temperature while running more efficiently than resistance heat only models. If the room temperature should fall more than 5°F from the set temperature the unit will run the resistance heater.

The fan operation is dependent on the fan mode selected, either continuous or cycling. Dip switch 5 controls the fan mode, see page 16 for setting.

When the outdoor coil temperature falls below 30°Ffor more than

2 minutes the unitwill operate the resistance heaters and not the compressor. When the outdoor coil temperature reaches 45°F the compressor will be allowed to operate again.

Figure12

Digital ControlPanel

Temp

Mode

Fan

sMAnr

CENTER

Heat/Cool Models (PDE)

After pressing the 'Heat' button, adjust the temperature readout to the desired room temperatureand the unit will cycle the resistance heat on and off to maintain a comfortable room. The heater will come on anytime that the room temperature is 1.8°F below the desired temperature. The fan operation is dependent on the fan mode selected, either continuous or cycling. Dip switch 5 controls the fan mode, see page 16 for setting.

Emergency Heat Operation

In the event of a compressor failure in heat pump mode the compressor may be locked out to provide heat through the resistance heater. This feature ensures that even in the unlikely event of a compressor failure the room temperature can be maintained until the compressor can be serviced. Dip switch 7 controls the emergency heat setting, see page 16.

Fan Mode

Fan Only

Pressing the 'Fan Only' button will run the fan to allow for air circulation in the room without operating the compressor or heater regardless of the room or set temperature. The fan speed selection is made by pressing either the 'High Fan' or 'Low

Fan' button.

Cycle/Continuous

The owner may choose between fan cycling or fan continuous mode based on property preference.

(Note: Even heat monitoring and quiet start/stop fan delay only operate in fan

cycle mode) Fan continuous mode is used to keep constant airflow circulation in the room during all times the unit is 'ON'.

Fan cycle will conserve energy by only operating the fan while the compressor or electric heater is operating. Dip switch 5 controls the fan mode, see page 16 for setting.

17

920-087-04 (8@5)

RemoteThermostatand LowVoltageControl Connections

Remote Thermostat

All Friedrich PD model PTAC units are factory configured to be controlled by either the chassis mounted Smart Center or a 24V single stage remote wall mounted thermostat. The thermostat may be auto or manual changeover as long as the control configuration matches that of the PTAC unit.

Note: Torevert back to the Smart Center control of the unitreplace the jumper wire between the 'GI2 and 'GH' terminals that was removed in step 1.

To control the unit with a wall mounted thermostat follow

the steps below:

1) With the front cover removed locate the low voltage terminal strip at the lower portion of the Smart Center.

2) Remove the jumper between the 'GI2and GH' terminals.

3) The control is now configured for control by a wall thermostat. The Smart Center will no longer control the unit.

Thermostat Connections

C = Common Ground

W = Call for Heating

Y = Call for Cooling

R = 24V Power from Unit

GL = Call for Low Fan

GH = Call for High Fan

B = Reversing Valve Energized in heating mode

(PDH Models Only)

*If only one G terminal is present on thermostat connect to GL for low fan or to GH for high fan operation.

4) If desired the accessory escutcheon kit (PDXRT) is to be used, install it over the existing control panel.

Figure13

Control board with optional PDXRT escutcheon kit installed

{oo st o

U;se wu byWa l ® mostat

1o operate _t

18

920-087-04 (8-05)

Desk Control Terminals

The Friedrich PD model PTAC has built-in provisions for connection to an external switch to control power to the unit. The switch can be a central desk control system or even a normally open door switch.

For desk control operation connect one side of the switch to the

D1 terminal and the other to the D2 terminal (See figure 13).

Whenever the switch closes the unit operation will stop.

Maximum Wire Length for Desk Control Switch

Wire Size

#24

#22

#2O

#18

#16

Maximum Length

400 ft.

6OOft.

9OOft.

1500 ft.

2000 ft.

Note: The desk control system and switches must be field supplied.

Auxiliary Fan Control

The Smart Center also has the ability to control a 24VAC relay to activate an auxiliary, or transfer, fan. The outputs are listed as

F1 and F2 on the control board.

To connect the relay, simply wire one side of the relay to F1 and the other side to F2. Anytime that the PTAC fan runs the terminals will send a 24VAC signal to the relay. The relay must be 24 VAC,

50mA or less.

Note: The relay and auxiliary fans must be field supplied.

NOTE: It is the installer's responsibility to ensure that all control wiring connections are made in accordance with the installation instructions. Improper connection of the thermostat control wiring and/or tampering with the unit's internal wiring can void the equipment warranty and may result in property damage, personal injury or death. Other manufacturer's PTACs and even older

Friedrich models may have different control wire connections.

Questions concerning proper connections to the unit should be directed to the factory.

G. FreshAir Vent Control

The vent control lever is located behind the front cover on the left side of the unit. The unit is shipped in the closed position with a locking screw in place. The screw must be removed to operate the lever. When the lever is back, (OPEN), outside air is mixed with indoor air. When the lever is forward, (CLOSED), no outside air is admitted into the room and room air is recycled through the unit.

NOTE: The vent should remain closed for peak operating efficiency.

OPEN

OUVERT

ABIERTA

VENT

AERATION

SALIDA (ESCAPE)

DEL AiRE

CLOSED

FERME

CERRADA

FRESH AIR DOOR IS FACTORY

SHIPPED IN CLOSED POSITION.

REMOVE TOP SCREW

TO OPEN DOOR.

ON LEVER

250-453-01

H. Air DischargeGrille

Moving parts hazard,

Turn off electric power before servicing this component.

Failure to do so can result in property damage, personal injury and/or death.

The air discharge grille can be redirected to blow air either straight up or at an angle into the room. Tochange the airflow direction, remove the front cover, locate and remove the six grill retaining screws. Reverse the ends of the grille and refasten the grille to the cover.

19

[]

[]

I. Start-upChecklist

F!

Inspect all components and accessories for damage before and after installation.

Check installation for compliance with all national and local codes and ordinances.

Read and follow all manufacturer's installation instructions.

[]

[]

[] Check that circuit breaker(s) and electrical wire sizes are correct.

If the unit is supplied with a power supply cord, insure that it is stored properly.

[]

Check the condensate water drain outlet(s) to make sure they are in compliance with all national and local codes, that they are adequate for the removal of condensate water, and that they meet the approval of the end user.

Strictly follow installation instructions concerning clearances around the unit,

Secure components and accessories, such as the control door and front cover.

920-087-04 (8-05)

[] Check the unit air filter, condenser coil and evaporator coil for any obstructions,

[]

[]

Check for proper operation of all components.

Instruct the owner or operator of the units operation, and the manufacturer's recommended routine maintenance schedule,

NOTE: It is highly recommended

that a maintenance

schedule log book be prepared for recording

the dates and times of service.

[] Operate the unit for twenty minutes, Record the unit's indoor/outdoor intake and discharge temperatures, amperage draw, and power voltage.

[]

Assemble the Warranty Certificate, the Operation and Installation Manual, all accessory installation instructions and the name, address and telephone number of the Authorized Friedrich Warranty

Service Company in the area for the owner or operator,

NOTE: Units are to be installed, inspected, and checked by qualified service personnel only.

20

920-087-04 (8-05)

AppendixA: Electrical Wiringfor 265 Volt Models

NOTE: It is recommended that the PXSB subbase assembly, the PXCJ conduit kit and the PXDS disconnect switch be installed on all hardwired units. If installing a flush-floor mounted unit, make provisions for all the line voltage power leads and conduit to be removed for ease of maintenance and service to the chassis.

To install the line voltage power leads and conduit to the chassis, follow the instructions below.

1. Remove the four control box retaining screws (A) and open the control box.

2. Pull the chassis power lead wires (B) (located on the bottomright side of the control box) through the plastic bushing so they are located inside the control box.

5. Make the appropriate electrical connections within the control box, then secure the box on the chassis. Detailed instructions are included with the installation instructions for the conduit kit (PXCJ).

3. Remove the plastic bushing.

6. Route the line voltage power conduit from the control box straight down the right front to the bottom side of the chassis. This will allow thefront cover to be installed without interference with the electrical conduit.

4. Route the line voltage power leads through the hole where the plastic bushingwas located, and secure its conduit (use a 1!2" straight conduit connector, with the Iocknut on the inside of the control box.)

Figure15

LineVoltageConnections

Inside back of control panel cover.

Screws

Screws

Fuse holder

21

920-087-04 (8-05)

J. RoutineMaintenance

NOTE: Units are to be inspected and serviced by qualified service personnel only.

1. Clean the unit air intake filter at least every 300 to 350 hours of operation. Clean the filters with a mild detergent in warm water and allow to dry thoroughly before reinstalling.

2. The indoor coil (evaporator coil), the outdoor coil (condenser coil) and base pan should be inspected periodically (yearly or bi-yearly) and cleaned of all debris (lint, dirt, leaves,paper, etc.). Clean the coils and base pan with a soft brush and compressed air or vacuum. If using a pressure washer, be careful notto bend the aluminium fin pack. Use a sweeping up and down motion in the direction of the vertical aluminum fin pack when pressure cleaning coils. Cover all electrical components to protect them from water or spray.

Before reinstalling the chassis in the sleeve, inspect the indoor blower housing, blower wheel, condenser fan blade, and condenser shroud periodically (yearly or bi-yearly) and clean of all debris (lint, dirt, mold, fungus, etc.) Clean the blower housing area and blowerwheel with an antibacterial

/ antifungal cleaner. Use a biodegradable cleaning agent and degreaser on condenser fan and condenser shroud.

Use warm or cold water when rinsing these items. Allow the unit to dry thoroughly, inspect all gasket material for deterioration (replace as necessary), and then reinstall the chassis in the sleeve.

NOTE: Do not use a caustic coil cleaning agent on coils or base pan. Use a biodegradable cleaning agent and degreaser.

Periodically (at least yearly or bi-yearly): inspect all control components, both electrical and mechanical, as well as the power supply. Use proper testing instruments (voltmeter, ohmmeter, ammeter, wattmeter, etc.) to perform electrical tests. Use an air conditioning or refrigeration thermometer to check room, outdoor and coil operating temperatures.

Use a sling psychrometer to measure wet bulb temperatures indoors and outdoors.

,

Inspect the surrounding area (inside and outside) to ensure that the units' clearances have not been compromised or altered.

Inspect the sleeve and drain system periodically (at least yearly or bi-yearly) and clean of all obstructions and debris.

Clean both areas with an antibacterial and antifungal cleaner. Rinse both items thoroughly with water and ensure that the drain outlets are operating correctly. Check the sealant around the sleeve and reseal areas as needed.

,

Clean the front cover when needed. Use a mild detergent.

Wash and rinse with warm water. Allow them to dry thoroughly before reinstalling them in the chassis.

Figure16

Components

Condenser Fan Blade

Indoor Blower

Condenser Gasket

Condenser Shroud

Filters

Discharge Air Grille

Indoor Blower

Housing

Outdoor Grille

3ressor Wall Sleeve

Return Air

Grille Evaporator Coil

Control Panel

22

920-087-04 (8-05)

K. BasicTroubleshootingTechniques

Being familiar with the sequence of operation on Standard Controlled Operating Units or the operation of the Remote Thermostat

Controlled Units is important. The following questions and answers may help to identify performance problems.

EnvironmentalEffects- Cooling Mode

Is unitsizedto roomsize areaand heat loaddemand?

The number of people in the room, number of electrical devices, solar gains, etc. are all variable items that can affect proper sizing of the unit. Friedrich recommends that you consult with an applications engineer for proper sizing.

Is the outdoortemperature 60°F or below?

The unit is designed for outdoor temperatures above 60°R

Isthe indoortemperature 80°For above?

Ambient indoor temperatures of 80°F or above will take a longer period of run time to cool down the area. Long run times may indicate that the unit is undersized.

Is indoorhumidityhigh?

This condition will cause the unit to operate longer to remove humidity before noticing any cooling effect.

Has the heat load been increased by additional devicessuch as computerequipment, or has the roomarea been increased where the unit is located?

If conditions have changed, the unit may not be able to cool and condition as effectively as previously planned.

Environmental Effects- Heating Mode

Is unitproperlysizedto roomarea and heat loaddemand?

The number of people in the room, number of electrical devices, solar gains, etc. are all variable items that can affect proper sizing of the unit. Friedrich recommends that you consult with an applications engineer for proper sizing.

Isthe outdoortemperaturo70°For above?

The unit is designed for outdoor temperatures below 70°R

Is the indoor temperature 60°F or below? Ambient indoor temperatures of 60°F or below will take a longer period of run time to heat the area. Long run times may indicate that the unit is undersized.

Hasthe roomarea been increasedwherethe unitis located?

If the area where the unit is located has been increased, the unit may not provide adequate heat.

Insufficient Maintenance and Inspection

Installationerrorsare themost commoncause of poor performance.

Please follow installation instructions carefully. If other problems exist, see Maintenance and Inspection Troubleshooting Guide below.

Maintenance and Inspection Troubleshooting Guide

CAUSE

System is not serviced or inspected regularly (semiannually or annually),

Air filters are not cleaned regularly and become blocked with particles,

Condenser coil not maintained properly (blocked with particles).

Evaporator coil not maintained properly

(blocked with particles),

Components that show signs of fatigue

- not replaced,

Condensate drains and drain lines not maintained.

RESULT

Can result in premature component failures, poor performance and increased operating costs.

May result in poor cooling, icing and water problems as well as component failures and increased operating costs.

May result in poor cooling, component failures and increased costs.

May result in poor cooling, icing and water problems, and increased operating costs.

May result in multiple service calls, poor performance and increased operating costs.

May result in water and odor problems.

23

920-087-04 (8-05)

Digital Control Diagnosticsand TestMode

Diagnostics

The Friedrich Smart Center continuously monitors the PTAC unit operation and will store service codes if certain conditions are witnessed.

In some cases the unit may take action and shut the unit off until conditions are corrected.

To access the error code menu press the 'Heat' and 'High Fan' buttons simultaneously for three seconds. If error codes are present they will be displayed. If multiple codes exist you can toggle between messages using the temp A button. To clear all codes press the temp v button for three seconds while in the error code mode. To exit without changing codes press the

'Low Fan' button.

TestMode

For service and diagnostic use only, the built-in timers and delays on the PTAC may be bypassed by pressing the 'Cool' and 'Low Fan' buttons simultaneously for three seconds while in any mode to enter the test mode. TEwill be displayed when entering test mode, and DEwill be displayed when exiting. The test mode will automatically be exited 30 minutes after entering it or by pressing the 'Cool' and 'Low Fan' buttons simultaneously for three seconds.

The chart below lists the possible error codes and their description:

Error

Code

02

Code Translation

NOT USED

An extreme low voltage condition exists <198V for 230V units and

<239V for 265V units,

Action Taken by Unit

NONE

Shut down unit. Display Error code and flash.

Once voltage rises to normal level system power is restored.

Possible Cause

• Inadequate power supply

• Defective breaker

• Blown fuse

03

Return air thermistor sensor open or short circuit

Set return air sensor = 75°F. Alternate flash set point and error code. Leave unit running.

• Defective sensor

o,_I n.g

06 n"/

u/

08

Indoor coil thermistor sensor open

Or short circuit

Outdoor coil thermistor sensor open Or short circuit

IfO.D. coil Temperature > 175 Deg

F for 2 consecutive minutes. (Heat

Pump models only)

Alternate flash set point and error code. Shut unit down for 5 minutes, then try again 2 times, if fails the 3rd time, then shut down unit.

I.D coil temperature <30 Deg F for

2 consecutive minutes.

If unit cycles (Heat or Cool demand)> 9 times per hour

Set ID coil temp = 40°F. Alternate flash set point and error code. Leave unit running.

Set OD coil temp = 20°F. Alternate flash set point and error code.

Automatically change over to

Electric heat Mode only. Leave unit running.

• Defective sensor

• Defective sensor

Alternate flash set point and error code. Continue fan operation while the compressor is locked out until the indoor coil thermistor reaches 45 ° F, and then energize the compressor. However, compressor must still wait a lockout time of 180 to 240 seconds.

Alternate flash set point and error code. Keep unit running.

• Dirty coil

• Fan motor failure

• Restricted air flow

• Non-condensables in refrigeration system

• Dirty filters

• Dirty coil

• Fan motor failure

• Restricted airflow

• Improper refrigerant charge

• Restriction in refrigerant circuit

• Unit oversized

• Low load conditions

nS, If unit cycles (Heat or Cool demand)< 3 times per hour

Alternate flash set point and error code. Keep unit running.

• Unit undersized

• High load conditions

.,n u

Room Freeze Protection triggered

Alternate flash set point and error code. Keep unit running.

• Room temperature fell below 40°F

24

920-087-04 (8-05)

Friedrich PTACAccessories

MODELNUMBER

PDXWS

PXGA

PXAA

PXDB

PXSC

PXDR10

DESCRIPTION

WALL SLEEVE zinc coated steel is prepared in an eleven-step process, then powder coated with a polyester finish and cured in an oven for exceptional durability. The wall sleeve is insulated for sound absorption and thermal efficiency.

16" High x 42" Wide x 13¾" Deep.

GRILLE standard, stamped aluminium, anodized to resist chalking and oxidation.

ARCHITECTURAL GRILLES Consist of heavy-gauge

6063-T5 aluminum alloy:

PXAAClear, extruded aluminum

PXDBDark bronze acrylic enamel

PXSCAlso available in custom colors.

CONDENSATE DRAIN KIT Attaches to the bottom of the wall sleeve for internal draining of condensate or to the rear wall sleeve flange for external draining. Recommended on all units to remove excess condensate. Packaged in quantities of ten.

PDXWS

PXDB

PXDR10

PHOTO

PXWE

PXSB

DEEP WALL SLEEVE EXTENSION Afour inchdeep anodized aluminium extension that attaches to the outside of the wall sleeve when the wall is greater than eleven inches thick (9½" when a subbase is used, 10 inches when a lateral duct is used).

PXWE

DECORATIVE SUBBASE Provides unit support for walls less than six inches thick. Includes leveling legs, side filler panels and mounting brackets for electrical accessories. Accepts circuit breaker, power disconnect switch, or conduit kit.

PXS_

RT2

PDXRT

DIGITAL REMOTE THERMOSTAT Digital electronic thermostat with "one touch" adjustment. Mounts to wall for control of unit.

RT2

PDXRT - REMOTE THERMOSTAT ESCUTCHEON KIT

This kit contains 10 escutcheons that can be placed over the factory control buttons when a remote wall mounted thermostat is used. The escutcheon directs the guest to the wall thermostat for operation and retains the LED window to display error codes and diagnostic information.

PDXRT

25

920-087-04 (8-05)

MODELNUMBER

PXSE

DESCRIPTION

SLEEVE EXTENSION RETROFIT KIT Zinc coated steel,

2.4" sleeve extension attached to the room side of the sleeve to allow for the installation of a P-Series Friedrich

PTAC in a T-Series sleeve.

PDXDA

PDXDE

LATERAL DUCTADAPTER Attaches to the PTAC/PTHP unit and provides a transition to direct up to 35% of the total

CFM to a secondary room, either left or right of the unit. Kit includes duct plenum with discharge grille and internalbaffle, adapter and end cap.

LATERAL DUCT EXTENSION A three foot insulated plenum that attaches to the left or right side of the duct adapter. The extension can be cut to length by the installer.

Maximum allowable straight extension is fifteen feet.

PXSE

PDXDA

PXDL

CONTROL DOOR LOCK KIT Locks control door to prevent tampering by unauthorized users

PXDL

PHOTO

PDXFT

REPLACEMENT FILTER PACK These are original equipment return air filters. They are reusable and can be cleaned by vacuuming, washing, or blowing out, and are sold in convenient ten packs. (Two filters per chassis)

PDXFT

26

PXCJ

CONDUIT KITWITH JUNCTION BOX Hardwire conduit kit with junction box for 208/230V and 265V units (subbase not required). Kitincludesa meansofquickdisconnectforeasy removal ofthe chassis. *Required for 265V installations.

PXPC

15/2o/3o

DESIGNATOR

S

C

PXCJ

POWERCORDRETROFITReplacesLCDtpowercordon 230V modelswhen unit is usedwith a subbase.PXPC15is usedwith

15 amp 2.5 kW units. PXPC20is used with 20 amp 3.4 kW units. PXPC30is usedwith 30 amp 5.0 kW units.

PXPC30

DESCRIPTION

STANDARD UNIT Standard PTAC/PTHP chassis. Can be 230/208V or 265V, electric or heat pump.

SEACOAST PROTECTION Additional protection for PTAC/PTHP units in a coastal or corrosive environment. The entire outdoor coil is submerged in a specially formulated enamel coating, then ovencured for a tough, corrosion-resistant finish.

920-087-04 (8-05)

Friedrich Air Conditioning

P.O. Box 1540

Company

San Antonio, TX 78295

210.357.4400

www.friedrich.com

PD-SERIES

PACKAGED TERMINAL AIR CONDITIONERS

LIMITED WARRANTY

SAVE THIS CERTIFICATE.

It gives you specific rights, you may also have other rights which may vary from state to state and province to province.

In the event that your unit needs servicing, contact your nearest authorized service center.

If you do not know the nearest service center, ask the company that installed your unit or contact us - see address and telephone number above. When requesting service: please have the model and serial number from your unit readily available.

Unless specified otherwise herein, the following applies: PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS

LIMITED WARRANTY - FIRST YEAR (Eighteen (18) Months from the original date of purchase or twelve (12) months from installation).

Any defect in the unit's material or workmanship will be repaired or replaced free of charge by our authorized service center during the normal working hours; and

LIMITED WARRANTY - SECOND THROUGH FIFTH YEAR (Sixty-six (66) months from the date of purchase) ON THE SEALED

REFRIGERATION

SYSTEM.

Any part of the sealed refrigeration system on the P-series that is defective in material or workmanship will be repaired or replaced free of charge (excluding freight charges) by our authorized service center during normal working hours.

The sealed refrigeration system consists of the compressor, metering device,

evaporator,

condenser, reversing valve, check valve, and the interconnecting tubing.

These warranties

apply only while the unit remains at the original site and only to units installed inside the continental United

States, Alaska, Hawaii, Puerto Rico and Canada.

The warranty applies only if the unit is installed and operated in accordance with the printed instructions and in compliance with applicable local installation and building codes and good trade practices. For international warranty information, contact the Friedrich Air Conditioning Company - International Division.

Reasonable proof must be presented to establish the original purchase date, otherwise the beginning date of this certificate will be considered to be our shipment date plus sixty days. Replacement parts can be new or remanufactured.

Replacement parts and labor are only warranted for any unused portion of the unit's warranty.

We will not be responsible for and the user will pay for:

1. Service calls to:

A) Instruct on unit operation.

B) Replace house fuses or correct house wiring. C) Clean or replace air filters. D) Remove the unit from inaccessible locations. E) Correct improper installations.

2. Parts or labor provided by anyone other than an authorized service center.

3. Damage caused by:

A) Accident, abuse, negligence, misuse, riot, fire, flood, or acts of God.

B) Operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or any damaging chemicals (other than in a normal residential environment).

C)

Unauthorized alteration or repair of the unit, which in turn affects its stability or performance.

D) Failing to provide proper maintenance and service.

E) Using other than a "Seacoast Protected" unit in a coastal environment.

F) Using an incorrect power source. G) Faulty installation or application of the unit.

We shall not be liable for any incidental,

consequential,

or special damages or expenses in connection with any use or failure of this unit.

We have not made and do not make any representation or warranty of fitness for a particular use or purpose and there is no implied condition of fitness for a particular use or purpose.

We make no expressed

warranties

except as stated in this certificate.

No one is authorized to change this certificate or to create for us any other obligation or liability in connection with this unit.

Any implied warranties shall last for one year after the original purchase date.

Some states and provinces do not allow limitations on how long an implied warranty or condition lasts, so the above limitations or exclusions may not apply to you. The provisions of this warranty are in addition to and net a modification of or subtraction from the statutory warranties and other rights and remedies provided by law.

In case of any questions regarding the provisions of this warranty, the English version will govern.

(12-04)

27

FriedrichAir ConditioningCo.

PostOffice Box 1540

San Antonio, Texas78295-1540

4200 N. Pan Am Expressway• San Antonio, Texas78218-5212

(210) 357-4400 • FAX (210) 357-4480 www.friedrich.com

Printed in the U,S,A.

920-087-04 (8-05)