Internal Use Only http://biz.lgservice.com
Room Air Conditioner
SVC MANUAL(Exploded View)
MODEL : AMNW09GDBL0 [LMN096HVT]
CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
1. Specification
Indoor
Model
Power Supply
Capacity(*)
Current
Fan
Running Current
Motor Type
Fan Type
Motor Output(W) x No. of Unit
Ø / V / Hz
Btu/h Class
A
Air Flow Rate
(H / M / L)
External Static Pressure
Capacitor
CMM
CFM mmAq
μF / Vac
Coil
Drive
Row x Column x FPI
Dimensions Body
(W x H x D)
Decorative Panel mm inch mm inch kg (lbs) kg (lbs)
Net Weight Body
Decorative Panel
Air Filter
Sound Level (H / M / L)
Piping
Connections
Liquid
Gas
Drain(OD/ID)
Dehumidification Rate dB(A)+3 mm (inch) mm (inch) mm(inch) l/h
Safety Devices
Temperature Sensor
Refrigerant
Refrigerant Control
Transmission Interunit Cable No. x AWG
AMNW09GDBL0
[LMN096HVT]
AMNW12GDBL0
[LMN126HVT]
1/208-230/60
9,000
0.15
BLDC
Cross Flow Fan
14.4 x 1
7 / 6.5 / 6
247/230/212
-
-
Direct Drive
2R x 16C x 23
885 x 285 x 210
34-27/32 x 11-7/32 x 8-9/32
-
-
1/208-230/60
12,000
0.15
BLDC
Cross Flow Fan
14.4 x 1
9.5 / 9 / 8.5
336/318/300
-
-
Direct Drive
2R x 16C x 23
885 x 285 x 210
34-27/32 x 11-7/32 x 8-9/32
-
-
11(24.5)
-
Long Life Filter
33 / 30 / 27
6.35 (1/4)
9.52 (3/8)
21.5/16 (0.846/0.630)
1.1
11(24.5)
-
Long Life Filter
39 / 36 / 31
6.35 (1/4)
9.52 (3/8)
21.5/16 (0.846/0.630)
1.2
Fuse, Thermal Protector for Fan Motor
Thermistor Thermistor
R410A
EEV(in Outdoor unit or BD)
4×18(including earth)
R410A
EEV(in Outdoor unit or BD)
4×18(including earth)
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.
Conversion Formula kW = Btu/h x 0.0002931
cfm = CMM x 35.3
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
- 2 -
LGE Internal Use Only
2. Piping Diagrams
Th4 Heat exchanger
CFF
Th3
Th1
Gas pipe connection port
(flare connection)
Th2
Liquid pipe connection port
(flare connection)
Cooling
Heating
LOC.
Description
Th1 Thermistor for sunction air temperature
Th2 Thermistor for evaporator inlet temperature
Th3 Thermistor for evaporator outlet temperature
Th4 Thermistor for evaporator middle temperature
PCB Connector
CN-TH1(Indoor)
CN-TH2(Indoor)
CN-TH3(Indoor)
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
- 3 -
LGE Internal Use Only
3. Wiring Diagrams
Indoor Unit
CN-MOTOR1 CN-U/D1 CN-INLET
CN-L/R1 CN-OPTION
CN-HVB
CN-LIMIT CN-SUB2
CN-H/S
CN-SUB1
CN-TH
CN-LIMIT
CN-12V
CN-DISP1
CN-TH1
CN-TH2
CN-TH3
CN-SW
CN-DISP
MAIN PCB
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
- 4 -
LGE Internal Use Only
4. Exploded View
135316
268711K
152313
Option Part
159830
W6631C
135500B
268711J
268711H
152302
131410
135313
267110
146811B
354212
352150
149303
149304
342800
135500A
354210
W51620A
W51620B
359011
263230C
135500C
135080
346810
266090
268711C
733010
263230B
147582
145200
135311
147581
146811A
35211B
749740
268711D
249951
W6640A
263230A
Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes
- 5 -
LGE Internal Use Only
P/NO : MFL61777625 NOVEMBER, 2010