HP StorageWorks 1000 Modular Smart Array storage array Maintenance and service guide
Below you will find brief information for storage array StorageWorks 1000 Modular Smart Array. The HP StorageWorks 1000 Modular Smart Array is a storage system that provides a variety of features to help you manage your data. This guide provides information about maintaining, servicing and troubleshooting the system.
Advertisement
Advertisement
HP StorageWorks 1000 Modular Smart Array maintenance and service guide
This guide provides procedures and diagnostics needed for the maintenance, service, and troubleshooting of the HP
StorageWorks 1000 Modular Smart Array (MSA1000 or MSA).
Part number: 257547–003
Third edition: October 2006
Legal and notice information
© Copyright 1999, 2002–2006-NaN Hewlett-Packard Development Company, L.P.
Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and
12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Microsoft, Windows, Windows XP, and Windows NT are U.S. registered trademarks of Microsoft Corporation.
Contents
About this guide . . . . . . . . . . . . . . . . . . . . . . . . . .
9
Intended audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Prerequisites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Related documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Document conventions and symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HP technical support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Customer self repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Subscription service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HP websites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Documentation feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Illustrated parts list . . . . . . . . . . . . . . . . . . . . . . . .
13
2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .
15
Chassis specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Memory specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power supply module specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCSI I/O module specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 System components and LEDs . . . . . . . . . . . . . . . . . . .
19
Front view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chassis and component LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chassis LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Controller LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hard drive LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCSI hard drive LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fibre Channel I/O module LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power supply/fan assembly LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCSI I/O module LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Available diagnostic tools . . . . . . . . . . . . . . . . . . . .
29
Array Configuration Utility (ACU) overview . . . . . . . . . . . . . . . . . . . . . . . . . .
Array Configuration Utility Command Line Interface (ACU-CLI) overview . . . . . . . . . . . . . .
MSA Command Line Interface (MSA-CLI) overview . . . . . . . . . . . . . . . . . . . . . . .
Array Diagnostics Utility (ADU) overview . . . . . . . . . . . . . . . . . . . . . . . . . . .
HP Systems Insight Manager (HP-SIM) overview . . . . . . . . . . . . . . . . . . . . . . . .
HP Storage Management Initiative Specification (SMIS) overview . . . . . . . . . . . . . . . . .
System Event Analyzer (SEA) overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 LCD panel and message descriptions . . . . . . . . . . . . . . . .
33
LCD panel overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LCD message types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Informational messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
User input messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LCD message descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
maintenance and service guide 3
6 Customer replaceable components . . . . . . . . . . . . . . . . .
59
Procedural overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Customer self repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Parts-only warranty service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Procuring the spare component . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Returning the defective component . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommended tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings and precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrostatic discharge information . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Grounding methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Equipment symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack warnings and precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Device warnings and precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Determining whether a component is hot-pluggable . . . . . . . . . . . . . . . . . . . . . . .
Connecting power to the MSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Applying power to the MSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing power from the MSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing or installing a Fibre Channel interconnect blank . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing an interconnect blank . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing an interconnect blank . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing or installing a hard drive blank . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing a hard drive blank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing a hard drive blank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing a hard drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying component failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying component failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the controller cache module . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the controller cache battery pack . . . . . . . . . . . . . . . . . . . . . . . .
Installing the controller cache battery pack . . . . . . . . . . . . . . . . . . . . . . . .
Installing the controller cache module . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing a Fibre Channel I/O module . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying component failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing a 2-Gb small form factor pluggable (SFP) transceiver . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying component failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing a power supply/fan assembly . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying component failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
Replacing a fan module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying component failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing the SCSI I/O module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying component failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing the power button module . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying component failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Removing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the component . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Verifying proper operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Replacing the MSA1000 chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Enclosure and hard drive migrations . . . . . . . . . . . . . . . .
95
Adding a new storage enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Migrating existing storage enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Moving hard drives or arrays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Capacity expansion and extension . . . . . . . . . . . . . . . . .
97
9 Hard drive failures and faulted LUNs . . . . . . . . . . . . . . . .
99
Recognizing hard drive failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Effects of hard drive failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Compromised fault tolerance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Recovering from compromised fault tolerance (enabling failed LUNs) . . . . . . . . . . . . . . . 100
Best practices when replacing hard drives . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
Automatic data recovery (rebuild) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Time required for a rebuild . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Failure of another drive during rebuild . . . . . . . . . . . . . . . . . . . . . . . . . . 103
10 Array controller firmware . . . . . . . . . . . . . . . . . . . . 105
Updating controller firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Cloning controller firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Recovering corrupted firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106
11 SCSI hard drive firmware . . . . . . . . . . . . . . . . . . . . 109
A Regulatory compliance and safety . . . . . . . . . . . . . . . . . 111
Regulatory compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Federal Communications Commission notice . . . . . . . . . . . . . . . . . . . . . . . . 111
Class A equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Class B equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
Declaration of conformity for products marked with the FCC logo, United States only . . . . . 112
Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Regulatory compliance identification numbers . . . . . . . . . . . . . . . . . . . . . . . 112
Regulatory compliance label location . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
International notices and statements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
maintenance and service guide 5
Canadian notice (avis Canadien) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Class A equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
Class B equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112
European Union notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
BSMI notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Japanese notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Korean notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Safety notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Battery replacement notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
Taiwan battery recycling notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Power cords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Japanese power cord notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Electrostatic discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Preventing electrostatic damage . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Grounding methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
6
Tables
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LCD panel messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Component hot-pluggability . . . . . . . . . . . . . . . . . . . . . . . . . . .
maintenance and service guide 7
8
About this guide
This guide provides information about:
• Maintaining the MSA
• Servicing the MSA
WARNING!
To reduce the risk of personal injury from electric shock and hazardous energy levels, do not exceed the level of repairs specified in these procedures. Troubleshooting and repair procedures included in this document are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, do not attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create conditions that are hazardous.
NOTE:
Any indications of component replacement or printed wiring board modifications may void any warranty.
Intended audience
This guide is intended for use by system administrators and technicians who are experienced with the following:
• SAN management
• Network administration
• Network installation
Prerequisites
Before servicing the MSA, make sure that you consider the following:
• Knowledge of operating system
• Knowledge of related hardware/software
• Previous version of the product and/or firmware version
Related documentation
The following documents provide related information:
• HP StorageWorks 1000 compatibility guide
• HP StorageWorks 1000 QuickSpecs
• HP StorageWorks 1000 configuration overview
• HP StorageWorks 1000 installation guide
• HP StorageWorks 1000 maintenance and service guide
• HP StorageWorks 1000 Command Line Interface user guide
• Configuring Arrays on HP Smart Array Controllers reference guide
Additional documents, such as release notes, whitepapers, and important notices may also exist for the
MSA.
maintenance and service guide 9
User documentation is available in the following locations:
• MSA1000/1500 documentation CD
• Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 .
• Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals .
In the Storage section, click Storage array systems and then, in the Modular Array Systems, click
HP StorageWorks 1000 Modular Smart Array.
Document conventions and symbols
Table 1 Document conventions
Convention
Blue text:
Element
Cross-reference links and e-mail addresses
Blue, underlined text: http://www.hp.com
Bold text
Italic text
Monospace text
Monospace, italic text
Monospace, bold text website addresses
• Keys that are pressed
• Text typed into a GUI element, such as a box
• GUI elements that are clicked or selected, such as menu and list items, buttons, tabs, and check boxes
Text emphasis
• File and directory names
• System output
• Code
• Commands, their arguments, and argument values
• Code variables
• Command variables
Emphasized monospace text
WARNING!
Indicates that failure to follow directions could result in bodily harm or death.
CAUTION:
Indicates that failure to follow directions could result in damage to equipment or data.
IMPORTANT:
Provides clarifying information or specific instructions.
NOTE:
Provides additional information.
TIP:
Provides helpful hints and shortcuts.
10 About this guide
HP technical support
For worldwide technical support information, see the HP support website: http://www.hp.com/support .
Before contacting HP, collect the following information:
• Product model names and numbers
• Technical support registration number (if applicable)
• Product serial numbers
• Error messages
• Operating system type and revision level
• Detailed questions
Customer self repair
HP customer self repair (CSR) programs allow you to repair your StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience.
Some parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair can be accomplished by CSR.
For more information about CSR, contact your local service provider. For North America, see the CSR website: http://www.hp.com/go/selfrepair .
Subscription service
HP recommends that you register your product at the Subscriber’s Choice for Business website: http://www.hp.com/go/e-updates .
After registering, you will receive e-mail notification of product enhancements, new driver versions, firmware updates, and other product resources.
HP websites
For additional information, see the following HP websites:
• http://www.hp.com
• http://www.hp.com/go/storage
• http://www.hp.com/service_locator
• http://www.hp.com/support/manuals
• http://www.hp.com/support/downloads
Documentation feedback
HP welcomes your feedback.
To make comments and suggestions about product documentation, please send a message to [email protected]
. All submissions become the property of HP.
maintenance and service guide 11
12 About this guide
1 Illustrated parts list
2
8
6
7
3
1
4
5
5
6
7
Item
4
Description
Standard shipping configuration items:
1 Chassis (with backplane)
229198–001
2 Blanking panel, MSA controller
229208–001
3
Service replacement module part number
MSA1000 controller with 256MB cache module
229203–001
Power button module 229201–001
8
Power supply module 212398–001
Blower/fan module 123482–001
SCSI I/O module with integrated EMU
229205–001
Fibre Channel I/O module
229206–001
Shipped items not illustrated:
AC power cords Contact HP Support
VHDCI SCSI cables Contact HP Support
Custom serial cable for CLI connection
316131–001
Additional/optional module part number n/a n/a
218231-B22 n/a n/a n/a n/a
218960-B21
Contact your HP
Authorized Reseller
Contact your HP
Authorized Reseller n/a
Customer Self Repair
Optional
Mandatory
Optional
Optional
Optional
Optional
Optional
Optional
Mandatory
Mandatory
Mandatory
15490 maintenance and service guide 13
Other available items:
SCSI hard drives Contact HP Support Contact your HP
Authorized Reseller
Optional
MSA1000 controller with 128MB cache
Cache module
(128MB) with battery
314718–001
171387–001 n/a n/a
Optional
Optional
Cache module
(256MB) with battery
262012–001 254786-B21 Optional
Cache battery kit
MSA Fabric Switch 6
(embedded option — obsolete)
MSA SAN Switch 2/8
(embedded option)
120978–001
218681–001
309503–001 n/a n/a
288247-B21
Optional
Optional
Optional
MSA Hub 2/3
(embedded option)
SFP transceiver
Blanking panel, Fibre
Channel I/O
Fibre Channel cables
Faulty component return kit
291436–001
229204–001
229200–001
Contact HP Support
249670–001
286763-B21
A6515B n/a
Contact your HP
Authorized Reseller n/a
Optional
Optional
Mandatory
Mandatory
Mandatory
Mandatory — Parts for which customer self repair is mandatory. These parts are designed for customer self repair. If you request HP to replace these parts, you will be charged for the travel and labor costs of the service.
Optional — Parts for which customer self repair is optional. These parts are designed for customer self repair. If, however, you require that HP replace them for you, this may be done at no additional charge under the type of warranty service designated for your product.
No — Parts for which customer self repair is not available. These parts are not designed for customer self repair. To satisfy the customer warranty, HP requires that an authorized service provider replace the component.
14 Illustrated parts list
2 Specifications
This chapter provides operating and performance specifications for the MSA1000.
Included in this section:
• Power supply module specifications
• SCSI I/O module specifications
NOTE:
For information on the components and their part numbers, see the
maintenance and service guide 15
Chassis specifications
Item
Height
Width
Depth
17.5 cm (6.9 in)
52.1 cm (20.5 in)
48.3 cm (19.0 in)
Weight (no hard drives installed, single power supply) 22.7 kg (50 lb)
International input voltage requirements
Rated input voltage
Rated input frequency
Rated input current
Input power (max)
100 to 240 VAC
50 Hz to 60 Hz
7.35 A Max
641 W*
Description
U.S. input voltage requirements
Rated input voltage
Rated input frequency
Rated input current
Input power (max)
Power supply specifications
Rated steady-state power
Maximum peak power
Btus
Temperature range
Operating
100 VAC to 240 VAC
50 Hz to 60 Hz
7.35 A Max
641 W*
377 watts
681 watts
2187 Btu/hr*
Shipping
10° to 35° C (derated 1°C per 1000 feet of elevation to 10000 ft.); (50° to 95° F)
-30° to 50° C (-22° to 122° F)
Relative humidity (noncondensing)
Operating
Non-operating
Maximum wet-bulb temperature
Long term storage
Short term storage
10% to 90% up to 95%
29°C (84.2°F)
30°C (86°F)
Idle
Fixed drive (random writes)
<6.9 and 53
<7.3 and 54
* Input power and heat dissipation specifications are maximum values and apply to worst-case conditions at full rated power supply load. The power/heat dissipation for your installation varies depending on the equipment configuration.
16 Specifications
Memory specifications
Item
Speed
Width
100 MHz minimum
80 bits
NOTE:
Use only HP battery-backed cache accelerator modules.
Description
Power supply module specifications
Item Description
Height
Width
Depth
Weight
12.7 cm (4.5 in)
15.9 cm (6.25 in)
24.1 cm (9.5 in)
2.9 kg (6.4 lb)
NOTE:
The MSA1000 System Unit power supply specifications are calculated without the fan.
SCSI I/O module specifications
Item
Height
Width
Depth
Weight
11.4 cm (4.5 in)
3.5 cm (1.375 in)
24.1 cm (9.5 in)
0.6 kg (1.3 lb)
Description maintenance and service guide 17
18 Specifications
3 System components and LEDs
This chapter includes figures and tables that identify system components and describe chassis and module LEDs patterns.
Included sections:
Front view
1 2 3 4
1 Controller blank
2 RJ-45Z serial port (to access the CLI)
3 MSA1000 controller
4 Controller LCD display panel
5 Power on/Standby button
6 Chassis status LEDs
7 Hard drives
7 6 5
15577 maintenance and service guide 19
Rear view
8 1
7 6 5 4 3 2 4 3 2
15578
1 Fibre Channel blanking panel
2 Power supply/blower assemblies
3 Power supply/blower assembly LEDs
4 AC power cord connectors
5 SCSI port A connector (enclosures connected to this port are labelled box 2)
6 SCSI port B connector (enclosures connected to this port are labelled box 3)
7 SCSI I/O module with integrated EMU
8 Fibre Channel I/O module
Chassis and component LEDs
The MSA chassis and its modular components are equipped with LEDs. When the fault LED on any MSA component is amber, promptly determine the reason for the alert by examining the component, the messages displayed on the MSA controller LCD panel, and system event logs (such as those provided by
HP Systems Insight Manager).
The following sections define the LEDs:
• Fibre Channel I/O Module LEDs
• Power supply / fan assembly LEDs
20 System components and LEDs
Chassis LEDs
The chassis LEDs provide fundamental status information about the MSA.
1
2
3
Item
1
Name
Heartbeat
2
3
Power
Fault
Condition
Blinking
Off/Solid
On
Off
On
Off
Color
Green
Amber
Green
—
Amber
—
15582
Meaning
Normal
Power off or fault
Power on
Power off or system in Standby state
Fault detected in one or more subsystems
Normal — no faults detected
NOTE:
System power does not shut off completely with the power button. Standby removes power from most of the electronics and the hard drives, but portions of the power supply and some internal circuitry remain active. To remove the power completely, disconnect all power cords from the device. For instructions, see
maintenance and service guide 21
Controller LEDs
During normal runtime, the array controller has 18 LEDs that indicate controller activity or malfunction.
15 14 13 12 11 10 9 8 17
7 6 5 4 3 2 1 0 16
Item
1
2
Name
Drive failure
Cache activity
6
7
3
4
5
SCSI bus 1 activity
SCSI bus 0 activity
Logical I/O activity
Direct Memory Access
(DMA) activity
Active/Standby
8
9
10
Heartbeat
Fault
Redundancy active
11–13 Busy status — These three LEDs are used to progressively represent the processing load on the controller.
14–18 Fibre Channel ID
—
On
Off
Condition
On
On
Off
Blinking
On
On
On
On
On
Off
Blinking
On (amber)
On (green)
15588
Meaning
A configured hard drive has failed.
Cache active.
No cache activity.
Cache transfer pending.
Activity on the bus.
Activity on the bus.
Currently processing logical requests from the host adapter.
DMA transfers are active.
This controller is active.
This controller is standby.
The controller is functioning properly.
An error message has been sent to the controller LCD display panel.
The two controllers and the two Fibre
Channel I/O modules are in a redundant mode of operation.
The controller is idle.
The controller is operating at full capacity.
Indicates the 5–bit Arbitrated Loop Physical
Address (ALPA) assigned to this array controller (not applicable in fabric mode).
22 System components and LEDs
Hard drive LEDs
When a hard drive is configured as a part of an array and attached to a powered-on controller, the status of the hard drive can be determined from the illumination pattern of its LEDs.
IMPORTANT:
For additional information on replacing a hard drive, see
and
Hard drive failure and faulted LUNs
.
SCSI hard drive LEDs
Each SCSI hard drive has three LEDs. The following figure and table describe their locations and meanings.
1
2
3
1
Activity LED
On
2
Online LED
Off
3
Fault LED
Off
Blinking
Off
Blinking
Off
Blinking
Off
15584
Meaning
The hard drive is being accessed in one of the following ways:
• The hard drive is not configured as part of an array.
• The hard drive is a replacement and rebuild has not yet started.
• The hard drive is spinning up during POST.
Do not remove the hard drive. Removing a hard drive at this time could terminate the current operation and cause data loss.
The hard drive is being accessed in one of the following ways:
• The hard drive is part of a configured array that is being selected or updated by the ACU or MSA-CLI.
• The hard drive is being upgraded.
• The hard drive has been selected for identification in HP-SIM,
ACU, or MSA-CLI.
Do not remove the hard drive. Removing a hard drive at this time can cause data loss in non-fault-tolerant configurations.
The hard drive is not being accessed and is not configured as part of an array. If necessary, it is safe to replace the hard drive.
This hard drive is in one of the following states:
• The hard drive is not configured as part of an array.
• The hard drive is configured as an online spare.
maintenance and service guide 23
On or Off‘
Off
Off, On, or
Blinking
Blinking
Off
On
Off
On
Off
Off, On, or
Blinking
On or Off Blinking
The hard drive is being accessed in one of the following ways:
• The hard drive is a replacement hard drive and is being rebuilt.
• If the online LEDs of all of the other hard drives in the array are blinking, an expansion is occurring.
Do not remove the hard drive. Removing a hard drive at this time can cause data loss.
The hard drive has failed and has been placed offline. It is safe to replace the hard drive.
The hard drive is online and configured as part of an array, If necessary, and if all other hard drives in the same array are online and working, it is safe to replace the hard drive. one of the following is happening:
• If the Activity LED is Off, the drive is configured and online, but not currently active.
• If the Activity LED is On or blinking, the drive is configured and online, and is currently active.
A predictive failure alert has been received for this drive. Replace the hard drive as soon as possible.
24 System components and LEDs
Fibre Channel I/O module LEDs
The Fibre Channel I/O module has three LEDs. The following figure and table describe their locations and meanings.
2
1
3
15587
Item
1
2
3
Name
Status
1-Gb link status
2-Gb link status
Condition
Off
Solid
Blinking
Solid
Blinking
Solid
Color
—
Green
Amber
Green
Amber
Green
Meaning
Power not applied to Fibre Channel
I/O module, controller not plugged in, or unsuccessful controller POST
Power applied and connection established between Fibre Channel
I/O module and Fibre Channel controller
Power is applied but there is no link to the controller or there is no c-ontroller present
A 1-Gb link is established and the status is good
A 1-Gb link was established but is now inactive
A 2-Gb link is established and the status is good
Blinking Amber A 2-Gb link was established but is now inactive
NOTE:
If both link status lights are Off, a link has not been established since the application of power, initiation of a reset, hot-plug of Fibre Channel I/O module, removal of the transceiver, or hot-plug of the transceiver.
If both link status lights are blinking amber, the MSA controller has been removed or a link cannot be established.
maintenance and service guide 25
Power supply/fan assembly LEDs
Each power supply/fan assembly has one LED.
The LED is illuminated when both the power supply and the fan are operational. When a power supply or fan fault occurs, the LED goes off. If the LED is off, AC power is not present or there is a complete power supply failure.
15583
The power-supply-mounted fans cool the chassis by circulating air through the enclosure. The rate at which air moves (the airflow) determines the amount of cooling. This airflow is a function of fan speed
(rpm). These fans, under the control of the Environmental Monitoring Unit (EMU) or the associated power supply, can operate at multiple speeds. This ensures that when the enclosure temperature changes, the fans can automatically adjust the airflow. If one fan operates too slowly or completely shuts off, the other fan operates at a higher speed. At the same time, the error condition is reported to the user via the LCD panel on the front of the controller.
26 System components and LEDs
SCSI I/O module LEDs
The SCSI I/O module with integrated EMU has three LEDs. The following figure and table describe their locations and meanings.
1 2 3
Item
1
2
3
Name
Power/status
SCSI activity (port A)
SCSI activity (port B)
Condition
Solid
Off
Blinking
Off
Blinking
Off
Color
Green
—
Green
—
Green
—
15586
Meaning
Power on
Power off/fault
Activity
Off
Activity
Off maintenance and service guide 27
28 System components and LEDs
4 Available diagnostic tools
The following is a partial list of the tools that are supported for use with the MSA:
• Array Configuration Utility (ACU) overview
• Array Configuration Utility - Command Line Interface overview
• MSA Command Line Interface (MSA-CLI) overivew
• Array Diagnostics Utility (ADU) overview
• HP Systems Insight Manager (HP-SIM) overview
• HP Storage Management Initiative Specification (SMIS) overview
• System Event Analyzer (SEA) overview
Array Configuration Utility (ACU) overview
The Array Configuration Utility (ACU) is a browser-based tool used to configure an array controller and its storage. The ACU
The ACU is supported for use in Windows, Linux, and NetWare environments and can run locally through a browser, remotely through HP Systems Insight Manager (HP-SIM), or offline from the MSA
Support Software CD.
The ACU:
• Runs online in Windows and Linux environments.
• Runs offline (from a bootable CD) in other ProLiant server environments such as NetWare.
• Provides a graphical view of HP drive array configurations.
• Includes easy-to-use configuration Wizards.
• Provides different operating modes, enabling faster configuration or greater control over the configuration options.
• Suggests the optimum configuration for unconfigured systems.
• Displays on-screen tips for individual steps of a configuration procedure.
• Allows the setting of access privileges to specific storage LUNs to be limited to specific hosts.
• Supports online array capacity expansion, logical drive extension, assignment of online spares, and
RAID or stripe size migration
NOTE:
For optimum performance, the minimum display settings are 800 × 600 resolution and 256 colors.
Servers running Microsoft operating systems require Internet Explorer 5.5 (with Service Pack 1) or later.
For Linux servers, see the README.TXT file for additional browser and support information.
For Web or network access, a combination of the following may need to be installed and properly configured:
• Windows Internet Explorer
• TCP/IP and SNMP services
• Agents such as HP-SIM
• Host Bus Adapter drivers
For more information about the ACU, see the following:
• ACU section of the array configuration reference guide, available on the Documentation CD or the
Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 .
maintenance and service guide 29
• ACU website: http://h18000.www1.hp.com/products/servers/priliantstorage/ softwaer-management/acumatrix/index.html
.
Array Configuration Utility Command Line Interface (ACU-CLI) overview
The Array Configuration Utility Command Line Interface (ACU-CLI) is a command line user interface used to configure an array controller and its storage.
The ACU-CLI is supported for use in Windows, Linux, and HP-UX environments and can run locally through a browser, remotely through HP Systems Insight Manager (HP-SIM), or offline from the MSA
Support Software CD.
For more information about the ACU-CLI, see the following:
• ACU-CLI section of the array configuration reference guide, available on the Documentation CD or the
Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 .
• ACU-CLI text file, available in the ACU-CLI folder on the Support Software CD.
MSA Command Line Interface (MSA-CLI) overview
The MSA Command Line Interface (MSA-CLI) is built into the MSA array controller firmware and offers a command level method of configuring, managing, and monitoring the array controller and its storage.
The MSA-CLI is accessed through a host computer connected to the customized RJ-45Z serial port on the front of the MSA controller.
This interface is provided for system administrators who prefer this method of system management, instead of a graphical user interface. All supported operating systems can access the CLI.
Sample tasks include: configuring the storage units (LUNs), limiting access to the storage, and viewing controller and storage setup and status information.
Array Diagnostics Utility (ADU) overview
The HP Array Diagnostic Utility (ADU) is a web-based application that creates a report on all HP storage controllers and hard drives. This report provides vital information to assist in identifying faults or conditions that may require attention.
Collected information includes:
• Hard drive errors
• Intermittent problems
• Pre-failure Notification
• Controller, array, and logical drive problems
• Third-party, possible counterfeit, or non-HP hard drives
• Array controller and hard drive firmware versions
• Length of hard drive service
• Physical and logical drive configuration information
• Serial numbers of hard drives and array controllers
The ADU is installed on a server in the network and is provided on the MSA Support Software CD.
HP Systems Insight Manager (HP-SIM) overview
HP Systems Insight Manager (HP-SIM) is a web-based application that allows system administrators to accomplish normal administrative tasks from any remote location, using a web browser. HP-SIM provides device management capabilities that consolidate and integrate management data from HP and third-party devices. HP-SIM reports hardware fault conditions (both failure and pre-failure) and collects
30 Available diagnostic tools
data for reporting and graphing. HP-SIM also provides base-level management of HP clients, printers, and selected storage.
HP recommends using HP-SIM to monitor the performance of your Windows, Linux, and NetWare systems.
IMPORTANT:
You must install and use HP-SIM to benefit from the Pre-Failure Warranty for processors, SAS, SCSI, and SATA hard drives, and memory modules.
HP-SIM can monitor the following MSA controller parameters:
• CPU usage
• Total number of read and write commands processed
• Average time to process a read or write command
HP-SIM can monitor the following LUN parameters:
• Total I/O count
• Number of read and write requests
• Number of sectors read or written
For more information, see the Management CD in the HP ProLiant Essentials Foundation Pack or the
HP-SIM web site: http://www.hp.com/go/hpsim .
HP Storage Management Initiative Specification (SMIS) overview
The Storage Management Initiative Specification (SMIS) is a new standard developed by the Storage
Networking Industry Association (SNIA).
The HP StorageWorks MSA-specific SMIS (MSA SMIS) provides the Web-Based Enterprise Management
(WBEM) interface for the management of HP StorageWorks MSA arrays. SMIS MSA can be installed on any host running Microsoft Windows 2000 or Windows 2003 Server. Note that this host must have a path through the SAN to the devices that are to be managed.
For more information about SMIS, go to the HP SMIS website: http://h18006.www1.hp.com/storage/ smis.html
For more information about DMTF SNIA listings of HP SMIS providers, see the SNIA website: http://www.snia.org/ctp/smi_conform
System Event Analyzer (SEA) overview
System Event Analyzer is a host-based fault analysis utility included with the Web-Based Service Enterprise
(WEBES) service tools. Each WEBES service tool adds functionality to the Directory, a process (or set of processes) that executes continuously. SEA provides the Director with the capability of capturing and interpreting hardware events. The analysis of events can be performed automatically or when requested by an outside process.
SEA provides background automatic analysis by monitoring the active binary event log (also called the system event log or error log) and processing events as they occur. The events in the binary event log file are checked against the analysis rules. If one or more of the events in the binary event log file meets the conditions specified in the rules, the analysis engine collects the error data and creates a problem report containing a description of the problem and any corrective actions required. After the problem report is created, it is distributed in accordance with the customer’s notification preferences.
SEA features:
• Error event analysis and translation
• Multi-event correlation (view events, traps, etc.) maintenance and service guide 31
• Manual and automatic (real-time) analysis capabilities on local or remote machines
• Filtering capabilities on error logs
• Automatic notification (customer or HP Support Center)
• Rule-based (allowing more frequent updates)
• Proactive indictment with the operating system
• Web and command line interfaces
For more information, go to the WEBES website: http://h18023.www1.hp.com/support/svctools/ webes/?jumpid=reg_R1002_USEN .
32 Available diagnostic tools
5 LCD panel and message descriptions
NOTE:
Some messages may specify a box number. For the MSA1000, the following box numbers are defined:
Pre-defined box number Physical connection to MSA SCSI I/O module
Box 1 This is the MSA1000 chassis
Box 2 Port A of the SCSI I/O module
Box 3 Port B of the SCSI I/O module
LCD panel overview
Each array controller contains an integrated Liquid Crystal Display (LCD). This module is used for displaying informational and error messages, showing the status of the module, and for providing user input when required.
Traditional Power-On Self-Test (POST) messages issued by the PCI-based controllers have been combined with runtime event notification messages to create a new set of controller display messages. The display module is capable of holding up to 100 messages. After this maximum size is reached, older messages are removed to make room for newer ones. When a new message is sent to the LCD, the display shows that message and ignores any previous scrolling position. This new message is now the most recent message available.
To use the input buttons on the LCD panel:
• Press the Up navigation button to view older messages.
• Press the Down navigation button to view more recent messages.
• Press the Left navigation button to jump to the last message.
• Press the Right navigation button to enter the Management menu.
• Press the Left and Right navigation buttons at the same time to delete the currently displayed message.
The display module consists of the following components: maintenance and service guide 33
1 2 3 4 5
7 6
15576
1 Fault LED—indicates an internal MSA component failure or external storage enclosure failure
2 Two-line, twenty-column text message LCD display panel
3 Left navigation button
4 Up navigation button
5 Right navigation button
6 Down navigation button
7 Redundancy Link LED (dual-controller configurations only) — indicates that both array controllers and their corresponding Fibre Channel I/O modules are in a redundant mode of operation
LCD message types
The display module is capable of holding up to 100 messages. Once this maximum has been reached, older messages are removed to make room for newer ones. Messages can be of three types:
For a complete list of messages and their meanings, see
Error messages
Error messages indicate that a problem has occurred and may require user action to correct it.
The array controller Fault LED to the left of the LCD display panel lights whenever a new error message is sent to the display panel and has not been viewed, and when an error message is currently displayed for viewing. After all error messages have been viewed, the LED turns off and is re-lit only when an error message is currently being viewed or a new error message is sent to the display panel.
Informational messages
Informational messages indicate non-critical changes in the system that are provided as feedback to the user.
The array controller Fault LED to the left of the LCD display is off when an informational message is currently being viewed, unless an unviewed error message was previously sent to the display module.
After all error messages have been viewed, the LED returns to lighting up only when currently on an error message.
34 LCD panel and message descriptions
User input messages
User input messages indicate that the system has encountered a situation that allows user input. The user can select from a number of choices. If the user does not select one of the choices in a set amount of time, the system selects the default setting. These user input messages only occur during system power on, and not during runtime.
The array controller Fault LED to the left of the LCD panel display window blinks on and off when a user input message is currently being viewed and is available for input. If input is not provided within the time-out period, the message remains but the LED stops blinking.
LCD message descriptions
The following table describes the MSA LCD messages.
Table 2 LCD panel messages
Message
00 ARRAY CONTROLLER
FIRMWARE VER
<version>
02 ENABLE VOLUME
<n>?
'<'=NO,
'>'=YES
Type
Informational
01 STARTUP COMPLETE Informational
User input
Description
Displays the current version of firmware running on the
MSA array controller.
The array controller has completed its power-on sequence and is now operational.
An issue has been found with a configured volume that may result in data loss, so the volume has been disabled. The exact nature of the issue is detailed in a previous LCD display message.
03 CRITICAL LOCK-UP
DETECTED. CODE=<n>
Error A critical error has been detected by the array controller firmware. To prevent any possible data loss, the firmware has entered a lock-up state. The provided code contains engineering specific information about the lock-up condition.
Action
Yes = the volume is enabled
(regardless of the issue.) The volume attempts to return to its normal operating state and the data is accessible.
No = not selecting any option within the time-out period = the volume remains disabled. The volume stays in the failed state and the data is not be accessible.
During this time, the user can attempt to fix the issue.
no input = No
In dual-controller configurations where only one controller is locked-up, remove the array controller in question, wait 10 seconds, and then reinsert it ensuring that it is fully seated in the chassis.
In single-controller configurations and in dual-controller configurations where both controllers are locked-up, restart the MSA chassis.
Should the issue persist, contact HP support.
maintenance and service guide 35
Message
04 ENABLE VOLUMES ?
'<'=NO, '>'=YES
05 SYSTEM NAME
<name>
06 RESTARTING
SYSTEM
07 CLONE FIRMWARE?
'<'=NO, '>'=YES
Informational
User input
08 CONTROLLER TOO
OLD NOT SUPPORTED
09 PILOT 2 CONTRLR
NOT SUPPORTED
Error
Type
User input
Informational
Error
Description
An issue has been found with all of the configured volumes that may result in data loss. The exact nature of the issue is detailed in a previous display message.
Action
Yes = the volume is enabled
(regardless of the issue.) The volume attempts to return to its normal operating state and the data is accessible.
No = not selecting any option within the time-out period = the volume remains disabled. The volume stays in the failed state and the data is not be accessible.
During this time, the user can attempt to fix the issue.
no input = No
The user assigned name for the MSA system. This name can be assigned using the Array Configuration
Utility (ACU) or the MSA
Command Line Interface
(MSA-CLI).
The system is being restarted.
In dual-controller configurations only, the array controller has detected a firmware version mismatch with the two controllers and wants to copy the firmware from the other controller onto this controller. Firmware on both controllers must match.
Scroll through and read the messages on both controller
LCD panels to confirm the currently installed firmware versions on the controller.
Then, respond appropriately to the prompt.
< = No, do not clone.
> = Yes, proceed with the cloning.
no input = Yes, proceed with the clone.
During a restart of the MSA chassis, the controller with the latest version of firmware is cloned.
If a new or replacement controller is hot-added, the firmware on the already installed and active controller is cloned, even if less recent.
Contact HP support.
During startup, the firmware examines the hardware to ensure that it is supported for use with the version of installed firmware.
This controller is not supported.
During startup, the firmware examines the hardware to ensure that it is supported for use with the version of installed firmware.
This controller is not supported.
Contact HP support.
36 LCD panel and message descriptions
Message
10 FIRMWARE FLASH
FAILED
11 CLONING REFUSED
SYSTEM HALTED
Error
12 ONLINE UPGRADE
FLASHING FIRMWARE
13 ONLINE UPGRADE
FLASHING STARTED
14 ONLINE UPGRADE
FLASHING DONE
15 ONLINE UPGRADE
FLASHING FAILED
16 ONLINE UPGRADE
RESTARTING SYSTEM
17 ONLINE UPGRADE
COMPLETE
18 ONLINE UPGRADE
INCOMPLETE
19 ONLINE UPGRADE
REDUNDANCY HALTED
20 INITIALIZING
SCSI SUBSYSTEM
21 SCANNING FOR
SCSI DEVICES
22 INITIALIZING
SCSI DEVICES
Error
Type
Informational
Informational
Informational
Error
Informational
Informational
Error
Informational
Informational
Informational
Informational
Description
ROM flash failed.
Action
Download new firmware from the HP website and initiate the firmware update again.
If the issue persists, contact
HP support.
Firmware on the controllers must be updated to be the same.
A firmware mismatch was detected, message
07 CLONE FIRMWARE?
'<'=NO, '>'=YES was displayed, and the user selected < for “No”.
An online firmware update is starting.
An online firmware update is in progress.
An online firmware update has completed.
An online firmware update has failed.
Download new firmware from the HP website and initiate the firmware update again.
If the issue persists, contact
HP support.
An online firmware update is forcing an automatic restart of the system.
An online firmware update has completed successfully.
An online firmware update was successful, but a subsequent step failed. In dual-controller configurations, this may cause the other to not update properly.
In dual-controller configurations, each controller restarts at least once during an online firmware update. During these restarts, the system is not redundant.
The SCSI subsystem is being initialized as part of the power-on sequence.
The MSA is scanning for any attached SCSI devices as part of the power-on sequence.
The MSA is initializing all discovered SCSI devices as part of the power on sequence.
Restart the system.
In dual-controller configurations, if the
07 CLONE FIRMWARE?
'<'=NO, '>'=YES message is displayed, select >.
maintenance and service guide 37
Message
24 BAD SCSI BUS
MODE NON-LVD DEVICE
FOUND
Error
Type
25 FW VERSION IS
NOT SUPPORTED
Error
26 BAD SCSI TARGET Error
30 I2C READ FAILURE
<I2C device name>
Error
31 I2C WRITE
FAILURE <I2C device name>
Error
Description
The MSA does not support SCSI Single
Ended (SE) devices; it only supports SCSI Low
Voltage Differential (LVD) devices.
Action
The MSA should be powered off and then all SCSI devices attached to it should be examined. Any SE devices found should be removed and replaced with LVD devices.
Contact HP support.
During a firmware update, a check is made of the hardware to ensure that it is compatible with the version of firmware being installed.
This error indicates a problem.
The MSA is not properly identifying an external storage enclosure.
Do the following:
1.
Remove power from the
MSA and all attached storage enclosures.
2.
Re-seat all cables to the external storage enclosures.
3.
Verify that all cables are connected in a supported manner.
4.
Apply power to the external storage enclosures.
5.
Apply power to the
MSA.
Should the issue persist, contact HP support.
Should the issue persist, contact HP support.
The MSA has a number of internal devices that are accessed via an I2C hardware bus. One of these devices failed when attempting to read from it.
Certain I2C devices are considered critical and will result in a failure of the array controller while others may result in some loss of functionality (such as lost display messages).
The MSA has a number of internal devices that are accessed via an I2C hardware bus. One of these devices failed when attempting to write to it.
Certain I2C devices are considered critical and results in a failure of the array controller while others may result in some loss of functionality (such as lost display messages).
Should the issue persist, contact HP support.
38 LCD panel and message descriptions
Message
32 CHASSIS NVRAM
CONTENTS CORRUPTED
Error
Type
40 INITIALIZING
REDUNDANCY SUPPORT
Informational
41 REDUNDANCY
ACTIVE ACTIVE
CONTROLLER
42 REDUNDANCY
ACTIVE STANDBY
CONTROLLER
43 REDUNDANCY
FAILED HARDWARE
FAILURE
Informational
Informational
Error
Description
The MSA has non-volatile memory on it that contains required information needed to operate.
This non-volatile memory appears to be corrupted and the information is not valid. The MSA cannot continue to operate and halts.
Two array controllers are installed, and the they are attempting to enter redundant mode.
Two array controllers are installed, and they are now in redundant mode. This controller is active and can access configured volumes on the MSA.
Two array controllers are installed, and they are now in redundant mode. This controller is in standby and cannot access configured volumes on the MSA. This controller can be made active if the current active controller fails, assuming all redundant components are installed (I/O module, cables, and multipathing software).
While either attempting to enter redundant mode or already operating in redundant mode, one of the two installed array controllers encountered a hardware failure on the communication channel between the two array controllers. Redundancy is disabled at this time.
Action
Contact HP support.
If the MSA is currently involved in host I/O, remove the standby array controller, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis.
If this does not resolve the issue, wait until downtime is available. Power off the
MSA, remove both array controllers, and reinsert them, ensuring they are fully seated in the chassis.
Should the issue persist, contact HP support.
maintenance and service guide 39
Message
44 REDUNDANCY
FAILED MISMATCH
HARDWARE
45 REDUNDANCY
FAILED MISMATCH
FIRMWARE
46 REDUNDANCY
HALTED EXPAND
ACTIVE
47 REDUNDANCY
FAILED CACHE SIZE
MISMATCH
Error
Error
Type
Informational
Error
Description
Both array controllers must contain the same hardware for them to successfully enter redundant mode. The current array controllers do not contain the same hardware, possibly because one has an attached Fibre
Channel daughter card and the other does not.
Action
If the MSA is currently involved in host I/O, remove the standby array controller, add or replace the Fibre
Channel daughter card as needed, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis.
If this does not resolve the issue, wait until downtime is available. Power off the
MSA, remove both array controllers, add or remove
Fibre Channel daughter cards as needed on both, and reinsert them, ensuring they are fully seated in the chassis.
Should the issue persist, contact HP support.
Manually update the firmware on the older array controller. For instructions, see the MSA firmware updating guide.
Both array controllers must be running the same version of firmware for them to successfully enter redundant mode. A process called firmware cloning, which attempts to make them both the same firmware level, has failed.
If volume expansion is in progress then redundancy is not supported. Volume expansion is initiated and tracked using the Array
Configuration Utility (ACU).
After the volume expansion is complete, redundancy is automatically reestablished.
Both array controllers must have the same size of cache memory to successfully enter redundant mode.
If the MSA is currently involved in host I/O, remove the standby array controller, add or remove cache memory as needed, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis.
If this does not resolve the issue, wait until downtime is available. Power off the
MSA, remove both array controllers, add or remove cache memory as needed on both, and reinsert them, ensuring they are fully seated in the chassis.
Should the issue persist, contact HP support.
40 LCD panel and message descriptions
Message
48 REDUNDANCY
HALTED FIRMWARE
CLONED
49 REDUNDANCY
FAILED FIRMWARE
LOCKUP
50 REDUNDANCY
FAILED OUT OF
MEMORY
Type
Informational
Error
Error
51 REDUNDANCY
FAILED I/O REQUEST
ERROR
Error
Description
Both array controllers must run the same version of firmware for them to successfully enter redundant mode. A process called firmware cloning has been successfully completed in order to make them both the same firmware level.
The standby array controller is restarted automatically so they can attempt to achieve redundancy again.
While either attempting to enter redundant mode or already operating in redundant mode, one of the array controllers encountered a critical condition resulting in a firmware lockup.
Redundancy is disabled at this time.
While either attempting to enter redundant mode or already operating in redundant mode, one of the array controllers failed to allocate required memory.
Redundancy is disabled at this time.
While either attempting to enter redundant mode or already operating in redundant mode, one of the array controllers encountered an error while sending I/O between the two array controllers over the communication channel between them. Redundancy is disabled at this time.
Action
If the MSA is currently involved in host I/O, remove the standby array controller, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis.
If this does not resolve the issue, wait until downtime is available. Power off the
MSA, remove both array controllers, and reinsert them, ensuring they are fully seated in the chassis.
Should the issue persist, contact HP support.
If the MSA is currently involved in host I/O, remove the standby array controller, wait 10 seconds, and then reinsert it ensuring that it is fully seated in the chassis.
If this does not resolve the issue, wait until downtime is available. Power off the
MSA, remove both array controllers, and reinsert them, ensuring they are fully seated in the chassis.
Should the issue persist, contact HP support.
If the MSA is currently involved in host I/O, remove the standby array controller, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis.
If this does not resolve the issue, wait until downtime is available. Power off the
MSA, remove both array controllers, and reinsert them, ensuring they are fully seated in the chassis.
Should the issue persist, contact HP support.
maintenance and service guide 41
Message
52 REDUNDANCY
FAILED PCI BUS
ERROR
53 REDUNDANCY
FAILED NO SECOND
CONTROLLER
54 REDUNDANCY
FAILED CACHE DIMMS
MISMATCH
Error
55 MSA1000 ACTIVE
CONTROLLER
57 REMOVE OTHER
CONTROLLER NOW
Error
Error
Type
Informational
56 MSA1000 STANDBY
CONTROLLER
Informational
Error
Description
While either attempting to enter redundant mode or already operating in redundant mode, one of the array controllers encountered a PCI bus error on the communication channel used between the two array controllers.
Redundancy is disabled at this time.
Action
If the MSA is currently involved in host I/O, remove the standby array controller, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis.
If this does not resolve the issue, wait until downtime is available. Power off the
MSA, remove both array controllers, and reinsert them, ensuring they are fully seated in the chassis.
Should the issue persist, contact HP support.
Reinsert the missing array controller ensuring that it is fully seated in the chassis.
While operating in redundant mode, one of the array controllers was removed. Redundancy is disabled at this time.
The cache memory modules on the two controllers are not the same size. All cache memory modules must be the same size for redundancy to operate.
Remove the array controller that has been halted, replace the cache modules with the appropriately sized ones, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis.
In dual-controller active/passive configurations, this message is displayed on the active controller and
56 MSA1000 STANDBY
CONTROLLER is displayed on the standby controller.
In dual-controller active/ active configurations, this message is displayed on both controllers.
In dual-controller active/passive configurations, this message is displayed on the standby controller and
55 MSA1000 ACTIVE
CONTROLLER is displayed on the active controller.
In dual-controller configurations, the firmware has determined that the other controller has been disabled and can safely be removed.
Remove the other array controller for the planned service. When complete, reinsert the array controller, ensuring that it is fully seated in the chassis.
42 LCD panel and message descriptions
Message
60 NO CACHE MODULE
FOUND
61 DUAL CACHE
MODULE SIZE
MISMATCH
62 CACHE MODULE
#<n> <n>MB
Error
Type
63 VALID CACHE DATA
FOUND AT POWER-UP
Informational
64 CACHE DATA LOST
BATTERY DEAD
Error
65 CACHE HARDWARE
ENABLED
Error
Informational
Informational
66 CACHE HARDWARE
FAILED AND DISABLED
Error
Description
The array controller requires at least one cache module in order to operate. Either one is not present or it has failed.
The array controller has two cache modules attached but they are of different sizes. Both cache modules must be the same size.
Action
Remove the failed array controller, either add a cache module or replace the failed one, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis.
Should the issue persist, contact HP support.
Remove the failed array controller, replace one of the cache modules with a different one of the correct size, wait 10 seconds, and then reinsert it, ensuring that it is fully seated in the chassis.
The size of the cache module inserted into the indicated cache module slot.
Valid host data was found in the battery backed cache memory at power up. This data has been flushed to the hard drives.
The battery on the cache memory was no longer charged. If there was data in the cache memory, it is lost.
The cache hardware had been temporarily disabled but is now enabled again.
This may have been due to insufficient charge on the batteries that are now charged to capacity.
The cache memory has experienced a hardware failure.
If the failure has occurred on the standby array controller, remove the standby array controller, replace the cache modules, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis.
If the failure has occurred on the active array controller, wait until downtime is available. Power off the
MSA, remove the array controller, replace the cache modules, and reinsert the array controller, ensuring it is fully seated in the chassis.
Should the issue persist, contact HP support.
maintenance and service guide 43
Message
67 CACHE HARDWARE
TEMPORARILY
DISABLED
68 OBSOLETE CACHE
DATA DELETED
71 SYSTEM HALTED
FOR CACHE ERROR
Type
Informational
Informational
69 CACHE BATTERIES
LOW, RECHARGING
Informational
70 CACHE DISABLED
NO CONFIGURATION
Informational
Error
Description
The cache memory hardware has temporarily been disabled, typically because the battery is not charged or a capacity expansion operation is occurring. The cache automatically enabled once the condition has been corrected.
Old data that no longer belongs to any current configured volumes was found in the cache memory at power up. This data has been deleted. This typically happens if cache modules are moved between array controllers.
The batteries on the cache module are low and are being recharged.
The cache has not been configured and is disabled. The cache is configured using the Array
Configuration Utility (ACU) or MSA Command Line
Interface (MSA-CLI).
This message is displayed upon a no response to message 72 CACHE
ERROR <n> IGNORE?
<=NO >=YES .
Action
See the information for message 72 CACHE
ERROR.
44 LCD panel and message descriptions
Message
72 CACHE ERROR <n>
IGNORE? <=NO, >=YES
73 CACHE HARDWARE
BATTERIES MISSING
80 REPLACEMENT
DRIVE FOUND BOX
#<n> BAY <n>
Type
User input
Error
Informational
Description
During power up, data was found in the cache that could not be flushed to the hard drives. The reason is either because the data does not belong to this array controller (the cache module was moved from a different array controller) or the cache data is partial
(the rest of the data is in another cache module that was removed from the array controller). This error could occur if cache modules are moved improperly.
The cache module does not have its required batteries attached to it.
Action
If <n> = 1.1 or 1.2:
There is currently only one cache module in the array controller, but the controller was previously configured with a second cache module that is now missing.
If <n> = 2.1 or 2.2: A second cache module was added to this controller, but it contains data from its previous array controller.
If <n> = 2.3: The single cache module on this array controller was replaced, but with cache module containing data from a different array controller.
Return the cache module to its original array controller, power on the system without allowing any host I/O, and wait for cache data to be written to hard drives. The system can be powered off and the cache module moved to the new location.
< = no. The array controller will halt.
> = yes. Cache data will be erased and operation of the array controller will continue.
If the failure occurred on the standby array controller, remove the standby array controller, remove cache, attach cache batteries, replace the cache modules, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis.
If the failure occurred on the
active array controller, wait until downtime is available.
Power off the MSA, remove the array controller, replace the cache modules, and reinsert the array controller, ensuring it is fully seated in the chassis.
Should the issue persist, contact HP support.
A SCSI hard drive that was previously missing or failed has now been replaced with a working SCSI drive.
maintenance and service guide 45
Message
81 SMART DRIVE
ALERT BOX #<n>,
BAY <n>
82 DRIVE HOT ADDED
BOX #<n>, BAY <n>
Informational
83 DRIVE HOT
REMOVED BOX #<n>,
BAY <n>
84 DRIVE FAILURE
BOX #<n>, BAY <n>
85 BAD DRIVE
FRMWARE BOX #<n>,
BAY <n>
86 DRIVE POSITION
CHANGE DETECTED
87 DRIVE POSITION
CHANGE INVALID
Type
Informational
Informational
Error
Error
Informational
Informational
88 NON-COMPAQ DRIVE
BOX #<n>, BAY <n>
Informational
Description
A SCSI hard drive may be close to failing. This was determined either by the hard drive firmware itself using SMART technology or by the array controller using monitor and performance testing.
A SCSI hard drive has been added to the MSA chassis or attached external storage enclosure.
A SCSI hard drive has been removed from the MSA chassis or attached external storage enclosure.
A SCSI hard drive in the
MSA chassis or attached external storage enclosure has failed. If the hard drive was part of a configured volume, then the state of the volume will depend on the fault tolerance used.
A SCSI hard drive has been detected that has known, bad firmware on it.
Continued use of this hard drive could result in hard drive failure, decreased performance, or data loss.
The SCSI hard drives that make up a configured volume have been physically moved within the MSA1000 chassis or attached external storage enclosure. The array controller has updated its configuration information accordingly.
The SCSI hard drives that make up a configured volume have been physically moved in such a way that the array controller can no longer access the configured volume.
An unsupported hard drive was located in the indicated bay of the storage enclosure.
Action
The hard drive should be replaced as soon as possible.
The hard drive should be replaced as soon as possible.
Either the hard drive firmware should be updated or the hard drive should be replaced as soon as possible.
The MSA should be powered off and the hard drives restored to their original positions.
46 LCD panel and message descriptions
Message
89 INVALID CONFIG
BOX #<n>, BAY <n>
100 VOLUME #<n>
STATE OK
101 VOLUME #<n>
STATE FAILED
102 VOLUME #<n>
STATE INTERIM
RECOVERY
103 VOLUME #<n>
STATE REBUILDING
104 VOLUME #<n>
STATE DISABLED
105 VOLUME #<n>
STATE EXPANSION
ACTIVE
Error
Type
Informational
Error
Informational
Informational
Error
Informational
Description
For the MSA1500, before using an attached MSA20, the MSA20 is checked to see if any hard drives contain configuration data from a source other than the MSA1500. If so, the enclosure is failed and this message is displayed.
An MSA20 attached to an MSA1500 must be configured by the 1500.
Attaching an MSA20 that was configured by a Smart
Array Controller is not supported and will result in data loss of that existing
MSA20 configuration.
The configured volume has returned to its normal operating state. This typically occurs after a rebuild operation has completed.
The configured volume has been failed because too many SCSI hard drives that it is composed of have failed, exceeding the fault tolerance level. The data on the configured volume is no longer available. There is a risk of data loss.
The array controller has failed one or more
SCSI hard drives that the configured volume is composed of, but no data loss has occurred because fault tolerance is allowing the data to be recovered.
The configured volume is rebuilding data on a SCSI hard drive that replaced a previously failed drive.
The configured volume has been disabled because too many of the SCSI hard drives that it is composed of are missing.
Action
Replace the indicated hard drive.
The failed hard drives should be replaced as soon as possible. If necessary, restore data from backup.
The failed hard drives should be replaced as soon as possible.
Power off the MSA and all attached external storage enclosures. Unplug and reinsert all SCSI hard drives, ensuring they are fully seated in their bays. Check the cables connecting the MSA to any attached storage enclosures. Power on the attached storage enclosures and then the MSA.
The configured volume is currently performing a volume expansion operation.
maintenance and service guide 47
Message
106 VOLUME #<n>
STATE WAITING TO
REBUILD
107 VOLUME #<n>
STATE WAITING TO
EXPAND
108 VOLUME #<n>
STATE MISSING
DRIVES
109 VOLUME #<n>
STATE WRONG DRIVE
REPLACED
Type
Informational
Informational
Error
Error
110 VOLUME #<n>
EXPANSION DISABLED
Informational
111 VOLUME #<n>
INITIALIZING PARITY
Informational
Description
The configured volume is waiting to start rebuilding data on a SCSI hard drive that replaces a previously failed drive. The rebuild may not have started yet because the array controller is already performing a rebuild on another configured volume.
The configured volume is waiting to start a volume expansion operation.
The expansion may have not started yet because another configured volume is undergoing expansion or a rebuild is occurring on the configured volume.
The configured volume is missing too many of the
SCSI hard drives that it is composed of, making it unusable. The volume is disabled.
Action
The configured volume appears to have had known, good SCSI hard drives replaced instead of known, failed hard drives.
The volume expansion operation on the configured volume has been disabled.
This may be because a rebuild operation is ongoing, another expansion is already running, or the cache memory is disabled due to a low battery. The expansion will start once the condition has been cleared.
The array controller is calculating and storing parity information for the configured volume and therefore performance may be lower until it completes.
Power off the MSA and then all attached storage enclosures. Unplug and reinsert all SCSI hard drives ensuring they are fully seated in their bays. Check the cables connecting the MSA to any attached storage enclosures. Power on the attached enclosures and then the MSA.
The MSA should be powered off and the good hard drives should be restored while the failed hard drives should be replaced.
48 LCD panel and message descriptions
Message
112 VOLUME #<n>
REBUILD FAILURE
113 VOLUME #<n>
EXPANSION FAILURE
114 VOLUME #<n>
STATE DELETED
115 VOLUME #<n>
MEDIA EXCHANGED
120 CONFIGURED
VOLUMES <n>
121 NO VOLUMES
DETECTED
122 NEW VOLUME(S)
DETECTED
Error
Error
Type
Informational
Informational
Informational
Informational
Informational
Description
The rebuild operation on the configured volume has failed.
The volume expansion operation on the configured volume has failed.
Action
If the volume is still operating in regenerative mode, remove the new SCSI hard drive that was added as a replacement for the original failed hard drive and replace it with a different new drive.
Open the Array
Configuration Utility (ACU) or MSA Command Line
Interface (MSA-CLI) and use it to determine the state of the volume. If the volume is still operational, it is possible to retry the operation.
The configured volume has been deleted and is no longer available. Volumes are deleted by using the
Array Configuration Utility
(ACU) or MSA Command
Line Interface (MSA-CLI).
All failed hard drives of the specified volume have been replaced by good hard drives or all unplugged hard drives in the volume have been plugged back in. This message should be followed by message 02
ENABLE VOLUME <n>?
'<'=NO, '>'=YES.
The specified number of configured volumes was detected at power-up.
No configured volumes were detected at power-up.
See the entry for 02 ENABLE
VOLUME <n>?
'<'=NO,
'>'=YES.
If there are supposed to be configured volumes, power off the MSA and then all attached storage enclosures.
Unplug and reinsert all SCSI hard drives ensuring they are fully seated in their bays.
Check the cables connecting the MSA to any attached storage enclosures. Power on the attached enclosures and then the MSA.
Configured volumes from another array controller were migrated to this array controller. The configuration information has been updated.
maintenance and service guide 49
Message
123 TOO MANY
VOLUMES DETECTED
Error
125 ACCESS CONTROL
CONFLICT DETECTED
Error
126 ACCESS CONTROL
RESOURCES EXCEEDED
Error
Type
124 SPARES CLEARED Informational
150 BEACON ON Informational
Description
The array controller only supports a maximum of
32 configured volumes.
More volumes than that were detected at power up.
This typically occurs when migrating a set of volumes from one array controller to a different array controller that already has configured volumes on it. The migrated volumes have not been added.
A set of volumes has been migrated from one array controller to a different array controller that already has configured volumes on it. The migrated volumes have spares defined for them that conflict with the existing configuration. The defined spares have been deleted so as to allow the migration to proceed.
A set of volumes has been migrated from one array controller to a different array controller that already has configured volumes on it. The migrated volumes have access controls defined for them that conflict with the existing configuration. The access controls have been modified so as to allow the migration to proceed.
A set of volumes has been migrated from one array controller to a different array controllers that already has configured volumes on it. The migrated volumes have access controls defined for them that conflict with the existing configuration. The access controls have been modified so as to allow the migration to proceed.
The LEDs on the MSA and all connected hard drives are blinking because that array controller was selected for identification or configuration in a host-based application such as the ACU.
Action
Remove the migrated volumes and run the Array
Configuration Utility (ACU).
Delete any unneeded volumes until the number of existing volumes plus the number of migrated volumes is 32 or less. Add the migrated volumes back.
Run the Array Configuration
Utility (ACU) or MSA
Command Line Interface
(MSA-CLI) to reassign spare hard drives as needed.
Run the Array Configuration
Utility (ACU) or MSA
Command Line Interface
(MSA-CLI) to check the new access controls and modify them if needed.
Run the Array Configuration
Utility (ACU) or MSA
Command Line Interface
(MSA-CLI) to check the new access controls and modify them if needed.
50 LCD panel and message descriptions
Message
151 BEACON OFF
201 ARRAY
CONTROLLER
TEMPERATURE OK
202 ARRAY
CONTROLLER
OVERHEATING
203 ARRAY
CONTROLLER
OVERHEATED
205 ARRAY
CONTROLLER
RESTARTING
300 RECOVERY ROM
AUTOFLASH STARTED
Type
Informational
Informational
Error
Error
204 ARRAY
CONTROLLER DISABLED
Error
Informational
Informational
Description
The LEDs on the MSA and all connected hard drives are no longer blinking because the host-based application is no longer identifying or configuring this MSA.
The temperature sensor on the array controller indicates that the temperature that was previously exceeding the normal operating range is now back within the range.
The temperature sensor on the array controller indicates that the array controller is starting to exceed the normal operating range.
Action
The temperature sensor on the array controller indicates that the array controller has exceeded the safe operating range.
The array controller has been disabled due to a redundancy failure.
Check all MSA fans and ensure they are operating.
Any failed fan should be replaced. Ensure that there is a module or blanking panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the airflow and cooling ability of the
MSA.
The MSA should be powered off as soon as possible to avoid hardware failure.
Check all MSA fans and ensure they are operating.
Any failed fan should be replaced. Ensure that there is a module or blanking panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the airflow and cooling ability of the
MSA.
Remove the failed array controller, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis.
Should the issue persist, contact HP support.
The array controller has completed firmware cloning and will be restarted automatically.
The array controller has detected that the firmware's backup recovery ROM image is invalid and is copying the current active firmware image into the backup recovery ROM.
maintenance and service guide 51
Message
301 RECOVERY ROM
AUTOFLASH DONE
302 RECOVERY ROM
AUTOFLASH FAILED
303 ROM CLONING
STARTED
304 ROM CLONING
DONE
305 ROM CLONING
FAILED
Type
Informational
Error
Informational
Informational
Error
Description
The array controller has successfully completed the process of copying the current active firmware image into the backup recovery ROM.
The array controller failed to copy the current active firmware image into the backup recovery ROM.
Recovery ROM support is disabled.
Action
Remove the failing array controller, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis.
The ROM autoflash process is attempted again.
Should the issue persist, contact HP support.
In dual-controller MSA only, this indicates that the firmware from one of the controllers is being copied onto the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate.
If both array controllers are in the power-up sequence, then the most recent version of firmware will be used.
If one array controller has already completed the power-up sequence and is active, then its version of firmware will be used even if less recent.
In dual-controller MSA only, this indicates that the two array controllers in an MSA have finished copying one array controller's version of firmware to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate.
In dual-controller MSA only, this indicates that the two array controllers in an
MSA failed to copy one array controller's version of firmware to the other array controller. Both controllers must be running the same version of firmware in order for controller redundancy to operate.
Remove the standby array controller, wait 10 seconds, and then reinsert the array controller ensuring that it is fully seated in the chassis.
The ROM cloning process is attempted again.
Should the issue persist, contact HP support.
52 LCD panel and message descriptions
Message
306 FIRMWARE FLASH
STARTED
308 FIRMWARE FLASH
FAILED
Error
309 EMU FLASH
STARTED
311 EMU FLASH
FAILED
Type
Informational
307 FIRMWARE FLASH
DONE
Informational
312 FIRMWARE FLASH
STARTED ON BOX #<n>
Informational
313 FIRMWARE FLASH
DONE ON BOX #<n>
Informational
314 FIRMWARE FLASH
FAILED ON BOX #<n>
Error
400 STORAGE BOX
#<n> FAN OK
401 STORAGE BOX
#<n> FAN FAILED
Informational
310 EMU FLASH DONE Informational
Error
Informational
Error
Description
The array controller in the MSA has started the firmware flash process.
Do not turn off power to the system until it has completed. This could take several minutes.
The array controller in the
MSA has completed the firmware flash process. It is now safe to restart the MSA and begin using the new firmware. In dual-controller configurations, the new firmware is cloned onto the other controller during the startup routine.
The array controller in the MSA has failed the firmware flash process.
Action
The EMU has started the firmware flash process.
Do not turn off the power to the system until it has completed. This could take five minutes.
The EMU has completed the firmware flash process. It is now safe to turn off power to the system.
The EMU has failed the firmware flash process.
Attempt the flash process again.
Should the issue persist, contact HP support.
A firmware flash operation has started on an attached storage enclosure.
A firmware flash operation has completed on an attached storage enclosure.
A firmware flash operation has failed on an attached storage enclosure.
Attempt the flash process again.
Should the issue persist, contact HP support.
Restart the storage enclosure to enable the new firmware.
Attempt the flash process again.
Should the issue persist, contact HP support.
A fan in the specified storage enclosure that was previously marked as failed or degraded is now operating normally.
A fan in the specified storage enclosure has failed. The MSA may now be susceptible to overheating if corrective action is not taken.
Check all fans and ensure they are operating. Any failed fans should be replaced.
maintenance and service guide 53
Message
402 STORAGE BOX
#<n> FAN DEGRADED
409 STORAGE BOX
#<n> POWER SUPPLY
FAILED
410 STORAGE BOX
#<n> POWER SUPPLY
ADDED
411 STORAGE BOX
#<n> POWER SUPPLY
REMOVED
Error
Type
403 STORAGE BOX
#<n> FAN HOT
INSERTED
404 STORAGE BOX
#<n> FAN HOT
REMOVED
405 STORAGE BOX
#<n> TEMPERATURE OK
Informational
Informational
Informational
406 STORAGE BOX
#<n> OVERHEATING
407 STORAGE BOX
#<n> OVERHEATED
408 STORAGE BOX
#<n> POWER SUPPLY
OK
Error
Error
Informational
Error
Informational
Informational
Description
A fan in the specified storage enclosure is not operating at full efficiency.
The fan may eventually fail.
An fan in the specified storage enclosure has been hot-added.
A fan in the specified storage enclosure has been removed.
The temperature in the specified storage enclosure is now back in the normal operating range.
The temperature in the specified storage enclosure is starting to exceed the normal operating range.
The temperature in the specified storage enclosure has exceeded the safe operating range.
Action
Check all fans and ensure they are operating. Any failed fans should be replaced.
Check all fans and ensure they are operating. Any failed fans should be replaced. Ensure that there is a module or blanking panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the airflow and cooling ability of the
MSA.
The MSA should be powered off as soon as possible and immediately after that, the enclosure should be powered off, to avoid hardware failure.
Check all MSA fans and ensure they are operating.
Any failed fan should be replaced. Ensure that there is a module or blanking panel (cover plate) in all
MSA chassis bays and slots.
Empty bays affect the airflow and cooling ability of the
MSA.
The power supply in the specified storage enclosure that was previously marked as failed or degraded is now operating normally.
A power supply in the specified storage enclosure has failed.
Check all power supplies and ensure they are operating.
Any failed power supplies should be replaced.
A power supply in the specified storage enclosure has been added.
A power supply in the specified storage enclosure has been removed.
54 LCD panel and message descriptions
Message
412 STORAGE BOX
#<n> EMU NOT
RESPONDING
413 STORAGE BOX
#<n> EMU VERSION
<version>
414 STORAGE BOX
#<n> HOT REMOVED
415 STORAGE BOX
#<n> HOT ADDED
450 INVALID SCSI
CABLING BOX #<n>
500 INITIALIZING
PCI SUBSYSTEM
501 PCI SUBSYSTEM
HARDWARE FAILURE
510 INITIALIZING
FIBRE CHANNEL
SUBSYSTEM
Error
502 PCI BRIDGE ASIC
SELF TEST FAILURE
Error
Type
Informational
Informational
Informational
Error
Informational
Error
Informational
Description
An EMU in the specified storage enclosure is not responding to commands.
Action
Make sure the storage box is powered on. Ensure all cables are connected securely. Power off the MSA and the storage enclosure.
Then reapply power to the storage box and then the
MSA.
Should the issue persist, contact HP support.
The version of firmware running on the EMU. This is only displayed for the internal EMU of the MSA chassis. It is not displayed for externally connected storage boxes.
An external storage enclosure has been hot-removed from the back of the MSA.
An external storage enclosure has been hot-added to the back of the MSA.
The MSA has detected an external storage enclosure that is cabled incorrectly.
The array controller's
PCI subsystem is being initialized as part of the power-up sequence.
The array controller's PCI subsystem has encountered a critical error during the power-up sequence.
The array controller's
PCI bridge ASIC has encountered a critical error during the power-up sequence.
Remove the failed array controller, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis.
Should the issue persist, contact HP support.
Remove the failed array controller, wait 10 seconds, and then reinsert the array controller, ensuring that it is fully seated in the chassis.
Should the issue persist, contact HP support.
The array controller's Fibre
Channel subsystem is being initialized as part of the power-up sequence.
Verify that the external storage enclosures are connected properly to the
MSA. For more information, see the MSA installation guide.
maintenance and service guide 55
Message
511 FIBRE CHANNEL
SUBSYSTEM HARDWARE
FAILURE
514 FIBRE SWITCH
HARDWARE FAILURE
515 FIBRE DEVICE
HARDWARE FAILURE
Error
513 UNCORRECTED ECC
MEMORY ERROR SEEN
Error
Error
Error
516 FIBRE SUBSYSTEM
LINK FAILURE
Error
Type
517 FIBRE SUBSYSTEM
LINK OK
Informational
Description
The array controller's Fibre
Channel subsystem has encountered a critical error during the power up sequence.
The array controller has detected an uncorrectable error in the ECC memory on the memory cache board.
The embedded switch in the
Fibre Channel I/O bay is not responding correctly or is not working. (Please note that some switches take several minutes to start up.)
The array controller firmware does not recognize the device in the Fibre Channel I/O bay.
The device has failed or is not supported by the installed firmware version.
The controller is not currently linked to anything. This could be due to the following:
• The Fibre Channel cable is not connected.
• The device to which it is connected is currently not working.
• The MSA is connected to a device that with an incompatible port type.
Action
Remove the failed array controller and its associated
Fibre Channel module, reseat the Fibre Channel daughter card on the array controller, wait 10 seconds, then reinsert the Fibre
Channel module and the array controller, ensuring that they are fully seated in their respective bays in the chassis.
Should the issue persist, contact HP support.
Remove the failed array controller and replace the memory cache board with a new one.
Remove the embedded switch, wait 10 seconds, and then reinsert the switch, ensuring that it is fully seated in the chassis.
Should the issue persist, contact HP support.
If the device was not recently installed or the firmware was not recently downgraded, remove the embedded device, wait 10 seconds, and then reinsert the device, ensuring that it is fully seated in the chassis.
Should the issue persist, contact HP support.
Check the connections on both ends of the Fibre
Channel cables and make sure that the switch, hub, or other system that the fibre is connected to is operating properly and is properly configured.
Should the issue persist, contact HP support.
The Fibre Channel port has transitioned to an online state.
56 LCD panel and message descriptions
Message
518 PERSISTENT MEM
ENABLED
519 PERSISTENT MEM
DISABLED
Type
Informational
Informational
520 UNKNOWN I/O
MODULE DETECTED
Error
Description
Persistent memory data has been successfully initialized.
Persistent memory data has not been successfully initialized.
Some configuration data may not be available.
The MSA cannot determine the type of I/O module installed in the bay.
Action
Do the following:
1.
Remove power from any external storage enclosures.
2.
Remove power from the
MSA.
3.
Re-seat all Fibre Channel and SCSI I/O modules.
4.
Apply power to any external storage enclosures.
5.
Apply power to the
MSA.
6.
Verify that the MSA has the latest version firmware installed.
Should the issue persist, contact HP support.
maintenance and service guide 57
58 LCD panel and message descriptions
6 Customer replaceable components
This chapter includes the following information regarding the removal and replacement of MSA1000 components:
• Determining whether a component is hot-pluggable
• Removing or installing an interconnect blank
• Removing or installing a hard drive blank
• Replacing the controller, controller cache, or controller battery
• Replacing a Fibre Channel I/O module
• Replacing a 2-Gb small form factor pluggable (SFP) transceiver
• Replacing a power supply assembly
• Replacing the SCSI I/O module
• Replacing the power button module
• Replacing the MSA1000 chassis
IMPORTANT:
To reduce the risk of personal injury or damage to the equipment, observe all warnings and cautions throughout this chapter.
maintenance and service guide 59
Procedural overview
To help you successfully replace hardware components on your storage system, the following information is included in all component replacement procedures:
• Before you begin — This section may be included in the procedures to include component-specific precautions or notices. Be sure to read and observe these statements.
• Verifying component failure — Before replacing a component, make sure that you confer with HP technical support to verify that the hardware component has failed and that you are authorized to replace it yourself.
Verification procedures may include:
• Viewing status and error messages sent to the controller LCD panel.
• Viewing the LED illumination patterns on the MSA and the component.
• Viewing system event logs or other reports generated by system-management tools, such as HP Systems
Insight Manager (HP-SIM).
• Removing the failed component — The procedural steps to properly remove the component, including illustrations.
• Installing the component — The procedural steps to properly install the component, including illustrations.
• Verifying proper operation— After replacing the component, make sure to verify that the replacement component is operating properly.
Verification procedures may include:
• Viewing status and error messages sent to the controller LCD panel.
• Viewing the LED illumination patterns on the MSA and the component.
• Viewing system event logs or other reports generated by system-management tools, such as HP-SIM.
Customer self repair
HP products are designed with many Customer Self Repair (CSR) components to minimize repair time and allow for greater flexibility in performing defective parts replacement. If, during the diagnosis period, HP
(or HP service providers or partners) identifies that the repair can be accomplished by the use of a CSR port, HP will ship that part directly to you for replacement. There are two categories of CSR parts:
• Mandatory — parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.
• Optional — Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.
NOTE:
Some HP parts are not designed for customer self repair. To satisfy the customer warranty, HP requires that an authorized service provider replace the part. These parts are identified as
No
in the
.
Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits. If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days.
The defective part must be returned with the associated documentation in the provided shipping material.
Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.
60 Customer replaceable components
For more information about HP's customer Self Repair program, contact your local service provider. For the North American program, go to: http://www.hp.com/go/selfrepair .
Parts-only warranty service
Your HP Limited Warranty may include a parts-only warranty service. Under the terms of part-only warranty service, HP provides replacement parts free of charge.
For parts-only warranty service, CSR part replacement is mandatory. If you request HP to replace these parts for you, you are charged for the travel and labor costs of this service.
Procuring the spare component
lists the parts that qualify for CSR, including assembly and spare numbers. Parts have a nine-character component number on their label. The first six characters identify the element; the last three characters define the revision level. The replacement component revision level must be the same as, or later than, the number on the failed component. The greater the revision level, the later the revision.
Returning the defective component
In the materials shipped with a CSR component, HP specifies whether the defective component must be returned to HP. In cases where it is required, you must ship the defective part back to HP within a defined period of time, normally five business days. The defective part must be returned with the associated documentation in the provided shipping material. Failure to return the defective part may result in HP billing you for the replacement. With a CSR, HP will pay all shipping and part return costs and determine the courier/carrier to be used.
Recommended tools
When replacing certain components, such as the power button assembly, the following tools may be necessary:
• 4-mm flat-blade screwdriver
• Phillips screwdriver maintenance and service guide 61
Warnings and precautions
• Electrostatic Discharge Information
• Rack warnings and precautions
• Device warnings and precautions
Electrostatic discharge information
To prevent damage to the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage, observe the following precautions:
• Avoid hand contact by transporting products in static-safe containers such as conductive tubes, bags, or boxes.
• Keep electrostatic-sensitive parts in their containers until they arrive at static-free stations.
• Cover workstations with approved static-dissipating material. Provide a wrist strap connected to the work surface and properly grounded (earthed) tools and equipment.
• Keep work area free of nonconducting materials such as ordinary plastic assembly aids and foam packing.
• Place parts on a grounded surface before removing them from their containers.
• Avoid touching pins, leads, or circuitry.
• Make sure that you are properly grounded when touching a static-sensitive component or assembly.
• Place hard drives with the Printed Circuit Board (PCB) side down.
• Use conductive field service tools.
Grounding methods
There are several methods for grounding. Use one or more of the following methods when handling or installing electrostatic sensitive parts:
• Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis.
Wrist straps are flexible straps with a minimum of 1 megohm ±10% resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.
• Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.
• Use conductive field service tools.
• Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an Authorized HP
Reseller install the part.
NOTE:
For more information on static electricity or assistance with product installation, contact your HP
Authorized Reseller.
62 Customer replaceable components
Equipment symbols
The following symbols may be located on equipment in areas where hazardous conditions may exist.
WARNING!
Any enclosed surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. To reduce the risk of injury from electrical shock hazards, do not open this enclosure.
WARNING!
Any RJ-45 receptacle marked with these symbols indicates a network interface connection. To reduce the risk of electrical shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.
WARNING!
Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component. Contact with this surface could result in injury.
WARNING!
Power supplies or systems marked with these symbols indicate the presence of multiple sources of power.
WARNING!
Any product or assembly marked with these symbols indicates that the component exceeds the recommended weight for one individual to handle safely.
maintenance and service guide 63
Weight warning
WARNING!
The device can be very heavy. To reduce the risk of personal injury or damage to equipment:
• Remove all hot-pluggable power supplies and modules to reduce the overall weight of the device before lifting.
• Observe local health and safety requirements and guidelines for manual material handling.
• Get help to lift and stabilize the device during installation or removal, especially when the device is not fastened to the rails. When a device weighs more than 22.5 kg (50 lb), at least two people must lift the component into the rack together. If the component is loaded into the rack above chest level, a third person must assist in aligning the rails while the other two support the device.
Rack warnings and precautions
Ensure that precautions have been taken to provide for rack stability and safety. It is important to follow these precautions providing for rack stability and safety, and to protect both personnel and property.
Heed all cautions and warnings included in the installation instructions.
WARNING!
To reduce the risk of personal injury or damage to the equipment:
• Observe local occupational safety requirements and guidelines for heavy equipment handling.
• Obtain adequate assistance to lift and stabilize the product during installation or removal.
• Remove all pluggable power supplies and modules to reduce the weight of the product.
• Load the heaviest item first, and load the rack from the bottom up. This makes the rack
“bottom-heavy” and helps prevent the rack from becoming unstable.
• Extend the leveling jacks to the floor.
• Rest the full weight of the rack on the leveling jacks.
• Attach stabilizing feet to the rack if it is a single-rack installation.
• Ensure the racks are coupled in multiple-rack installations.
• Fully extend the bottom stabilizers on the equipment. Ensure that the equipment is properly supported/braced when installing options and boards.
• Be careful when sliding rack components with slide rails into the rack. The slide rails could pinch your fingertips.
• Ensure that the rack is adequately stabilized before extending a rack component with slide rails outside the rack. Extend only one component at a time. A rack may become unstable if more than one component is extended for any reason.
• Do not attempt to move a fully loaded equipment rack. Remove equipment from the rack before moving the rack.
• At least two people are needed to safely unload the rack from the pallet. An empty 42U rack weighs
115 kilograms (253 pounds), is over 2.1 meters (7 feet) tall, and can become unstable when being moved on its casters. Do not stand in front of the rack as it rolls down the ramp from the pallet; handle it from the sides. Stabilize the device by keeping the unit on the rails.
64 Customer replaceable components
WARNING!
Verify that the AC power supply branch circuit that provides power to the rack is not overloaded.
Overloading AC power to the rack power supply circuit increases the risk of personal injury, fire, or damage to the equipment. The total rack load should not exceed 80 percent of the branch circuit rating.
Consult the electrical authority having jurisdiction over your facility wiring and installation requirements.
Device warnings and precautions
WARNING!
To reduce the risk of electric shock or damage to the equipment:
• Allow the product to cool before removing covers and touching internal components.
• Do not disable the power cord grounding plug. The grounding plug is an important safety feature.
• Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
• Disconnect power from the device by unplugging the power cord from either the electrical outlet or the device.
• Do not use non-conductive tools that could bridge live parts.
• Remove all watches, rings, or loose jewelry when working in hot-plug areas of an energized device.
• Install the device in a controlled access location where only qualified personnel have access to the device.
• Power off the equipment and disconnect power to all AC power cords before removing any access covers for non-hot-pluggable areas.
• Do not replace non-hot-pluggable components while power is applied to the product. Power off the device and then disconnect all AC power cords.
• Do not exceed the level of repair specified in the procedures in the product documentation. All troubleshooting and repair procedures are detailed to allow only subassembly or module-level repair. Because of the complexity of the individual boards and subassemblies, do not attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety hazard.
WARNING!
To reduce the risk of personal injury or damage to the equipment, the installation of non-hot-pluggable components should be performed only by individuals who are qualified in servicing computer equipment, knowledgeable about the procedures and precautions, and trained to deal with products capable of producing hazardous energy levels.
WARNING!
To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material.
CAUTION:
Protect the installed solution from power fluctuations and temporary interruptions with a regulating
Uninterruptible Power Supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes, and keeps the system in operation during a power failure.
maintenance and service guide 65
CAUTION:
To properly ventilate the system, you must provide at least 7.6 centimeters (3.0 inches) of clearance at the front and back of the device.
CAUTION:
When removing or replacing a failed component, allow 30 seconds to pass before inserting a replacement component. This time is needed to allow the device to clear out the system registries.
CAUTION:
Schedule physical configuration changes during periods of low or no activity. If the system is performing rebuilds, RAID migrations, array expansions LUN expansions, or experiencing heavy I/O, avoid physical configuration changes such as adding or replacing hard drives or hot-plugging a controller or any other component. For example, hot-adding or replacing a controller while under heavy I/O may cause a momentary pause, performance decrease, or lass of access to the MSA while the new controller is starting up. When the controller completes the startup process, full functionality is restored.
CAUTION:
Before replacing a hot-pluggable component, ensure that steps have been taken to prevent loss of data.
66 Customer replaceable components
Determining whether a component is hot-pluggable
Before removing any serviceable part, determine whether the part is hot-pluggable or non-hot-pluggable.
• If the component is hot-pluggable, a power shutdown of the device is not required for replacement of the part.
• If the component is not hot-pluggable, the device must be powered down.
CAUTION:
Be sure the replacement is available before removing a component or blanking panel from the chassis.
Open slots dramatically impact airflow and cooling within the enclosure.
Table 3 Component hot-pluggability
Component
Redundant power supply/fan assembly
MSA array controller
(dual-controller configurations)
Hot-pluggable
X
X *
Non hot-pluggable
Fibre Channel I/O module
(dual-controller configurations)
X *
SCSI I/O module
MSA chassis
X
X
Power switch module
MSA array controller
(single-controller configurations)
X
X
Fibre Channel I/O module
(single-controller configurations)
X
* Before removing one of the two controllers or Fibre Channel I/O modules in an operational dual-controller
MSA, the controller being removed must first be disabled. For more information, see
Replacing the controller, controller cache, or controller battery
.
maintenance and service guide 67
Connecting power to the MSA
HP strongly recommends using the power cord shipped with the MSA. If using a different power cord, your power cord should be approved for use in your country. The power cord must be rated for the product and for the voltage and current marked on the electrical ratings label of the product. The voltage and current rating of the cord should be greater than the voltage and current rating marked on the product. In addition, the diameter of the wire must be a minimum of 1.02 mm² or 18 AWG. If you are using 18 AWG, your maximum length may be up to 3.65 meters (12 feet).
A power cord should be routed so that it is not likely to be walked on or pinched by items placed upon it or against it. Particular attention should be paid to the plug, electrical outlet, and the point where the cord exits from the product.
After all hardware components are installed and the unit is in place, the power can be connected.
WARNING!
To reduce the risk of electric shock or damage to the equipment:
• Do not disable the power cord's grounding plug. The grounding plug is an important safety feature.
• Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all times.
1.
Plug one end of the AC power cord into a power supply on the rear of the MSA. The power supply automatically senses the input voltage. It is not necessary to select the correct main voltage.
2.
Plug the other end of the AC power cord into a nearby, grounded outlet.
3.
Plug the second AC power cord into the redundant power supply.
4.
Plug the second AC power cord into a grounded outlet nearby.
68 Customer replaceable components
Applying power to the MSA
Before applying power to the MSA, all components of the storage system must be installed and connected to the supported interconnect options. Hard drives should be installed in the enclosures so that they can be identified and configured at power up.
The MSA and the other network components must be powered on in the following sequence:
1.
Verify that the following devices are powered on and in a ready state:
• Uninterruptible Power Supplies (UPS)
• External storage enclosures
• Network switches
NOTE:
Proceed to the next step only after these devices, especially the external storage enclosures have completed their startup routines. If the MSA is powered on before the external enclosures complete their startup sequence, the MSA may not properly discover the storage.
Any configured arrays may be marked as failed and will have to manually be re-enabled.
2.
Start up the MSA by pressing the Power/Standby button on the front of the MSA.
The LED on the Power/Standby button changes from amber to solid green, indicating that the
MSA has been powered on.
3.
Wait (up to four minutes) for the MSA to complete its startup routine.
NOTE:
If you installed a redundant controller and Fibre Channel I/O module in the MSA, the
CLONE FIRMWARE message might be displayed. Press the > button on the controller to copy the firmware from the right controller (Controller 1) to the left (new) controller
(Controller 2). In redundant configurations, the same firmware version must be installed on each controller.
4.
Press the < and > LCD panel message buttons on the front of each MSA controller, and look for the following message:
01 MSA Startup Complete
NOTE:
Proceed to the next step only after the Startup Complete message is displayed. If the server is powered on before the MSA completes its startup sequence, the server may not properly discover the storage.
5.
Power on (or restart) each server with access to the MSA and log on as a user with administrative control.
6.
Verify that each device in the network is operating properly.
maintenance and service guide 69
Removing power from the MSA
CAUTION:
System power to the MSA does not shut off completely with the power switch. The two positions of the front panel power switch should be considered as
On
and
Standby
, rather than
On
and
Off
. The standby position removes power from most of the electronics and the hard drives, but portions of the power supply and some internal circuitry remain active.
• To remove all power from the system, you must disconnect the power cord from the storage system.
• In systems with multiple power supplies, you must disconnect all the power cords to remove power completely from the system.
To remove power from the MSA, do the following:
1.
Ensure that a known good backup is available.
2.
Schedule a maintenance window.
3.
From the servers in the network, stop all access to the MSA.
4.
Press and hold down the MSA Power On/Standby button for five seconds to place the MSA in
Standby mode.
NOTE:
Placing the MSA in standby mode disables the main power supply output, but still provides auxiliary power (+5V) to the device.
5.
Verify that the Power On/Standby button LED is amber/off and that the fans are off.
6.
Disconnect all power cords from the AC outlets, and then from the device.
7.
Disconnect all external peripheral devices from the MSA.
70 Customer replaceable components
Removing or installing a Fibre Channel interconnect blank
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
Removing an interconnect blank
1.
Loosen the thumbscrew that holds the blank in place (1).
2.
Remove the blank from the back of the unit (2).
2
1
15568
Installing an interconnect blank
Place the blank into the MSA chassis bay and tighten the thumbscrew that holds the panel in place.
maintenance and service guide 71
Removing or installing a hard drive blank
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
Removing a hard drive blank
CAUTION:
A blank or a hard drive must be installed in each hard drive slot. Failure to install a blank or hard drive in all slots could result in thermal failures.
1.
Review all warnings, cautions, and preparation procedures as detailed in
.
2.
Push in the tabs to unlock the hard drive blank (1).
3.
Continue to press the tabs while pulling the hard drive blank out of the chassis (2).
1
2
15590
Installing a hard drive blank
Slide the blank into the enclosure chassis bay until it clicks into place.
72 Customer replaceable components
Replacing a hard drive
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
Verifying component failure
Hard drive failure is indicated by an amber Drive Failure LED.
CAUTION:
When replacing a hot-pluggable hard drive, it is important that you follow the guidelines in this section.
Failure to do so could result in data loss and could void your warranty.
CAUTION:
See the following for more information about replacing hard drives:
• Hard drive failure and faulted LUNs
• The HP ProLiant Servers Troubleshooting Guide, available on the Management CD
Removing the component
Follow these guidelines when replacing hard drives:
• Never remove more than one hard drive at a time (two if using RAID 6). When you replace a hard drive, the controller uses data from the other hard drives in the array to reconstruct data on the replacement hard drive. If you remove more than one hard drive, a complete data set is not available to reconstruct data on the replacement drive(s) and permanent data loss could occur.
• Never remove a working hard drive. The amber Drive Failure LED indicates a hard drive that has been failed by the controller. Permanent data loss will occur if a working hard drive is removed while replacing a failed drive.
• Never remove a hard drive while another hard drive is being rebuilt. A drive's Online LEDs flash green (once per second) while it is being rebuilt. A replaced hard drive is rebuilt from data stored on the other hard drives.
• If the system has an online spare drive, wait for it to complete rebuilding before replacing the failed drive. When a hard drive fails, the online spare becomes active and begins rebuilding as a replacement drive. After the online spare has completed Automatic Data Recovery (the online LEDs will be continuously lit), replace the failed hard drive with a new replacement drive. Do not replace the failed hard drive with the online spare. The system will automatically rebuild the replacement hard drive and reset the spare hard drive to an available state.
maintenance and service guide 73
• If you replace a hard drive while the system is off, it may be necessary to rebuild the replaced hard drive.
1.
Review all warnings, cautions, and preparation procedures as detailed in
.
2.
Be sure that the Online and Drive Access LED LEDs are both Off and that the Fault LED is On.
3.
Press the ejector button (1) and pull the release lever to the full open position (2).
4.
Wait approximately 10 seconds for the internal disk to stop spinning before continuing to the next step. Handling a hard drive while the internal media is spinning can damage the media.
5.
Pull the hard drive out of the enclosure bay (3).
3
1
2
15591
Installing the component
1.
Press the hard drive ejector button (1) and pull the release lever to the full open position (2).
2
1
15592
2.
Slide the replacement hard drive into the same bay from which the old hard drive was just removed, making sure that the lever is in the full open position to ensure a correct latch. Then, push the hard drive into the bay as far as it will go, pressing firmly on the hard drive to make sure that it is seated properly (1).
74 Customer replaceable components
2
1
15593
3.
Close the ejector lever against the front of the hard drive (2).
4.
Verify that the hard drive is firmly engaged and that the ejector lever is latched.
CAUTION:
Data can be lost if the hard drive is not firmly seated.
5.
As the hard drive begins to spin, the drive LEDs will illuminate, indicating that the system has recognized the new drive. In fault-tolerant configurations, allow the replacement hard drive to be reconstructed automatically from parity data stored on the other hard drives. While the data is being rebuilt, the LEDs will flash.
Verifying proper operation
The hard drive LEDs light one at a time and then turn off together to indicate that the system has recognized the new drive. In fault tolerant configurations, allow the replacement hard drive to be reconstructed automatically with data from the other hard drives. While reconstruction is in progress, the online LEDs flash.
maintenance and service guide 75
Replacing the controller, controller cache, or controller battery
The following sections detail procedures for replacing an MSA array controller, controller cache module, or controller cache battery pack:
• Removing the controller cache module
• Removing the controller cache battery pack
• Installing the controller cache battery pack
• Installing the controller cache module
Perform only the steps required for your service event. For example, re-seating an array controller includes
and
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
CAUTION:
• When replacing a controller, HP recommends that the old cache module be moved to the new controller. In single-controller configurations, if the controller fails, this ensures that disk writes that might have been trapped in the old controller's cache are completed.
• In dual-controller configurations, if a controller fails during an expand process, the old cache module
must
be migrated to the replacement controller to complete the expand process. If this is not done, the array contents are invalid.
• In dual-controller configurations, hot-add or hot-replace a controller or Fibre Channel I/O module only during periods of low I/O. Hot-adding or hot-replacing these modules while under heavy I/O may cause a momentary pause, performance decrease, or loss of access to the MSA while the new controller is starting up. After the startup process is complete, full functionality will be restored.
• In dual-controller configurations, the MSA controller and Fibre Channel I/O modules are hot-pluggable and the MSA does not need to be powered down during the replacement. However, you must first use an MSA management utility, such as the ACU or MSA-CLI to disable the controller before removal.
76 Customer replaceable components
Verifying component failure
Before replacing the controller, cache module, or battery pack:
• Check the controller LCD display panel for error messages.
• Record any failure LEDs or LCD panel messages for reference purposes.
• Check the controller heartbeat LED (1) . If the LED is not blinking, it might indicate a failure.
• Check the controller fault LED (2) . If the LED is on, it might indicate a failure.
1 2
15512
Removing the controller
1.
Review all warnings, cautions, and preparation procedures as detailed in
2.
Review all controller-specific warnings, cautions, and preparation procedures as detailed in
.
3.
In all single-controller configurations, power off the MSA as instructed in
4.
In operational dual-controller configurations, access an MSA management utility, such as the
MSA Command Line Interface (MSA-CLI) or the Array Configuration Utility (ACU) and disable the controller being removed. For instructions, see online help. (During this procedure, because one of the two controllers is being removed, the MSA operates in a non-redundant mode.)
5.
Press the controller thumb latch and rotate the latch handle out (1).
6.
Pull the controller straight out of the chassis (2).
2
1
15594 maintenance and service guide 77
Removing the controller cache module
If your system is equipped with a single controller, and you must replace the controller cache:
• You must schedule a maintenance window and remove power from the system to perform the service.
If your system is equipped with two controllers:
• and you are replacing a cache module with another module of the same size, you can remove one of the controllers and replace the module on that controller while the system is running.
• and you are replacing a cache module with a module of a different size, you must schedule a maintenance window and remove power from the system to then change the cache module on both controllers at the same time. The memory size of the cache modules must be the same on both controllers.
IMPORTANT:
Replacement controllers include a new cache module. Remove the new module from the replacement controller and replace it with the cache module from the failed controller. Using the same cache module completes disk writes trapped in the controller cache.
1.
Remove the controller from the chassis as instructed in
.
2.
Locate the controller cover clips on the rear, lower left, and right sides of the module by holding the controller upright with the latch handle facing you.
3.
Unlatch the controller cover clips (1) on the rear of the controller and raise the cover (2).
4.
Simultaneously unlatch the clips that are holding the controller cache in place (3).
5.
Carefully pull the cache module away from the controller board (4).
2
1
4
3
15514
Removing the controller cache battery pack
The controller cache module has two rechargeable and replaceable Nickel Metal Hydride (NiMH) battery packs. Under normal operating conditions, these should last for three years before replacement is necessary. They are continuously recharged via a trickle charging process whenever the MSA storage system is powered on.
Battery packs protect data on the controller cache module against equipment failure or power outage for up to four continuous days.
78 Customer replaceable components
WARNING!
There is a risk of explosion, fire, or personal injury if the battery pack is incorrectly replaced or mistreated. To reduce the risk:
• Do not attempt to recharge the battery outside of the controller.
• Do not expose to water or temperatures higher than 60˚C.
• Do not abuse, disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
• Replace only with the HP spare designated for this product.
CAUTION:
Do not dispose of batteries, battery packs, and accumulators with general household waste. Use the public collection system or return them to HP, your authorized HP Partners, or their agents.
NOTE:
• Always replace batteries in pairs, not individually.
• Temperature, age, and cache size can affect battery life. This time span also applies if the controller cache module is removed from the array controller. When power is restored to the storage system, an initialization process writes the preserved data to the hard drives. This is particularly important for data that has been cached by a posted-write operation, but has not yet been written to the hard drives.
• Batteries on a new controller might be discharged. In this case, a POST message is displayed on the controller display panel when the controller is powered on, indicating that the controller cache module is temporarily disabled. No user action is required, because internal circuitry automatically recharges the batteries. Recharging the batteries can take up to four hours. The controller functions properly during this time, although without the performance advantage of the controller cache module. When the batteries are charged to 90 percent of their capacity, the controller cache module is automatically enabled.
1.
Remove the controller as instructed in
.
2.
Remove the controller cache module as instructed in
Removing the controller cache module .
3.
Push down on the battery retaining clip, located near the lower corner of the module.
15516
4.
Swing the battery pack away from the cache module to about a 30-degree angle.
maintenance and service guide 79
15517
5.
Lift the pack upward to unhook the top of the battery pack.
15518
6.
Wait approximately 15 seconds after removing the old battery to allow the battery charge monitor to reset.
NOTE:
If you do not wait 15 seconds after removing the old battery, full charge of the new cache battery is delayed.
7.
Repeat
through
to remove the second battery pack on this cache module.
Installing the controller cache battery pack
1.
Remove the array controller as instructed in
2.
Remove the controller cache module as instructed in
Removing the controller cache module .
3.
Remove the controller cache battery pack as instructed in
Removing the controller cache battery pack
.
4.
Hook the top of the new NiMH battery pack to the top of the module, with the pack held at a
30-degree angle to the plane of the module.
80 Customer replaceable components
15519
5.
After the battery pack is hooked in position, swing the pack downward, ensuring that the bottom clip and two pegs line up with the holes in the cache module.
6.
Verify that the top hook (1) and bottom clip (2) on the battery pack are securely attached to the cache module.
1
2
15520
7.
Repeat
through
to install the second battery pack on the module.
8.
Install the serviced cache module in the controller as instructed in
Installing the controller cache module
.
NOTE:
The cache is disabled while the batteries are charging and is automatically re-enabled after the batteries are fully charged.
Installing the controller cache module
1.
Slide the cache module into the controller (1), until the side latches are fully engaged (2).
2
1
15515
2.
Close the controller cover.
3.
Insert the serviced controller into the chassis as instructed in
Installing the controller
1.
Insert the new or serviced array controller into the MSA chassis controller bay (1).
2.
Push the controller in as far as it will go, making sure that the controller is seated, and then press the latch handle inward until it is flush against the front panel (2).
maintenance and service guide 81
1
2
15595
3.
If necessary, power on the MSA as instructed in
and
NOTE:
Each time a system with two controllers is powered on or restarted, or if a second controller is hot-plugged into a single-controller configuration, the firmware versions on the controllers are compared.
If the firmware versions on the two controllers are not the same, the controller LCD panel prompts to clone the firmware from the controller with the latest version onto the other controller. For information, see
Verifying proper operation
After replacing the array controller, controller cache module, or cache module battery pack, verify that:
• The controller Heartbeat LED is blinking.
• The controller Fault LED is off.
• No new error messages are displayed on the array controller LCD display panel.
After installing a new array controller, verify that the latest available firmware is installed. See
for the following instructions:
• Determining the currently-installed firmware version
• Updating controller firmware
• Recovering corrupted firmware
82 Customer replaceable components
Replacing a Fibre Channel I/O module
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
CAUTION:
• In dual-controller configurations, hot-add or hot-replace a controller or Fibre Channel I/O module only during periods of low I/O. Hot-adding or hot-replacing these modules while under heavy I/O may cause a momentary pause, performance decrease, or loss of access to the MSA while the new controller is starting up. After the startup process is complete, full functionality will be restored.
• In dual-controller configurations, the MSA controller and Fibre Channel I/O modules are hot-pluggable and the MSA does not need to be powered down during the replacement. However, you must first use an MSA management utility, such as the ACU or MSA-CLI to disable the controller before removal.
Verifying component failure
Before replacing the Fibre Channel I/O module:
• Verify that the Fibre Channel I/O module Status LED is not illuminated or is flashing amber.
• Verify that the 1-Gb link status is blinking amber.
• Verify that the 2-Gb link status is blinking amber.
• Check the array controller LCD display panel for error messages.
Removing the component
CAUTION:
Stop all system access to the module before proceeding with these replacement procedures.
maintenance and service guide 83
CAUTION:
Use appropriate precautions when handling Fibre Channel cables:
• Touching the end of a Fibre Channel cable will either damage the cable or cause performance problems, including intermittent difficulties accessing the storage.
• Whenever a Fibre Channel cable is not connected, replace the protective covers on the ends of the cable.
• Make certain that the Fibre Channel cables are installed and supported so that no excess weight is placed on the connectors. This prevents damage to the connector and cable. Excess cable should be loosely coiled and tied out of the way, being careful not to coil the cable in a tight loop with a bend radius of less than 3 inches (7.62 cm).
1.
Review all warnings, cautions, and preparation procedures as detailed in
.
2.
Disconnect the cable from the Fibre Channel I/O module.
3.
While grasping the module handle (1), slide the release latch to the right. (2).
4.
Pull the module out of the chassis (3).
2
1
3
15569
Installing the component
1.
Slide the replacement Fibre Channel I/O module into the MSA chassis bay until the module clicks into place.
2.
Either move the SFP transceiver from the old Fibre Channel I/O module or install a new SFP transceiver in the new module. For instructions on removing and installing an SFP, see
2-Gb small form factor pluggable (SFP) transceiver
.
3.
Reconnect the cables.
Verifying proper operation
After replacing the failed Fibre Channel I/O module verify that:
• The Fibre Channel I/O module status LED is solid green.
• Verify that the 1-Gb link status is solid green.
• Verify that the 2-Gb link status is solid green.
• No new error messages are displayed on the array controller LCD panel.
84 Customer replaceable components
Replacing a 2-Gb small form factor pluggable (SFP) transceiver
The transceiver is hot-pluggable, so it is not necessary to power down the system to replace it.
Before you begin
WARNING!
To reduce the risk of injury from laser radiation or damage to the equipment, observe the following precautions:
• Do not open any panels, operate controls, make adjustments, or perform procedures to a laser device other than those specified herein.
• Do not stare into laser beam when panels are open.
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
Verifying component failure
Before replacing the SFP:
• Verify that the Fibre Channel I/O module status LED is not illuminated or is blinking amber.
• Check the array controller LCD display panel for error messages.
Removing the component
1.
Review all warnings, cautions, and preparation procedures as detailed in
2.
Press the release clip on the bottom of the cable connector to remove the Fibre Channel I/O cable from the back of the failed transceiver.
3.
Remove the transceiver, either by pulling on the plastic tab or by swiveling the small wire handle on the SFP, depending on the SFP model.
4.
Attach the protective cover on the cable and insert the dust plug cover in the failed SFP.
Installing the component
1.
Slide the replacement SFP into the port.
CAUTION:
To reduce the risk of damage to the equipment, do not use excessive force when inserting the SFP.
2.
Remove the protective cover on the cable and remove the dust-plug cover from the replacement SFP.
3.
Re-connect the Fibre Channel I/O cable to the SFP.
maintenance and service guide 85
Verifying proper operation
After replacing the failed SFP, verify that:
• The 1-Gb and 2-Gb link-status LEDs on the Fibre Channel I/O module cycle through blinking amber and green and then Off to indicate that the circuitry has recognized a newly installed SFP.
• The status LED on the Fibre Channel I/O module is solid green.
• No new error messages are displayed on the array controller LCD panel.
Replacing a power supply/fan assembly
The assembly is hot-pluggable, so it is not necessary to power down the system to replace it.
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
CAUTION:
• Replacement power supply assemblies do not include a variable speed fan. You must remove the operational fan from the defective power supply and install the fan on the new power supply.
• The fan blades rotate at a high speed and do not stop immediately when power is removed from the MSA. Allow time for the blades to stop rotating. Avoid touching the rotating blades when removing the fan.
• The fan shell must be handled carefully to avoid breaking it. Do not press on the center section of the fan shell (circular panel covering the blades). To avoid damaging the fan blades, grasp only the outer portion of the fan shell. Do not rest the power supply on the fan. Doing so might break the fan.
Verifying component failure
• Check the array controller LCD display panel for error messages.
• Verify that the electrical source is delivering power down the AC power cord.
• Verify that the power supply fault LED is flashing amber.
• Verify that the power supply Power on/off LED is Off.
Removing the component
1.
Review all warnings, cautions, and preparation procedures as detailed in
.
2.
Disengage the cord lock and disconnect the AC power cord from the failed power supply.
CAUTION:
When removing the left power supply, move the cord lock on the right power supply out of the way to avoid dislodging the right power supply and causing your system to become overheated.
86 Customer replaceable components
3.
While lifting up the power supply module latch (1), grasp the fan element and pull the defective power supply assembly out of the chassis (2).
1
2
15557
Installing the component
1.
Lift up on the power supply module latch (1) and slide the assembly into the chassis until it is fully seated (2).
1
2
15558
2.
Connect the AC power cord to the power supply.
3.
Engage the cord lock.
Verifying proper operation
After replacing the power supply, verify that:
• The power supply LED is solid green.
• No new error messages are displayed on the array controller LCD panel.
maintenance and service guide 87
Replacing a fan module
The variable-speed fan module is hot-pluggable, so it is not necessary to power down the system to replace it.
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
CAUTION:
• Replacement power supply assemblies do not include a variable speed fan. You must remove the operational fan from the defective power supply and install the fan on the new power supply.
• The fan blades rotate at a high speed and do not stop immediately when power is removed from the MSA. Allow time for the blades to stop rotating. Avoid touching the rotating blades when removing the fan.
• The fan shell must be handled carefully to avoid breaking it. Do not press on the center section of the fan shell (circular panel covering the blades). To avoid damaging the fan blades, grasp only the outer portion of the fan shell. Do not rest the power supply on the fan. Doing so might break the fan.
Verifying component failure
• Check the array controller LCD display panel for error messages.
• Verify that the electrical source is delivering power down the AC power cord.
• Verify that the blower module fault LED is flashing amber.
• Verify that the blower module Power on/off LED is Off.
Removing the component
1.
Review all warnings, cautions, and preparation procedures as detailed in
.
2.
Push in the two fan tabs (1) while pulling the fan element away from the power supply (2).
88 Customer replaceable components
2
1
1
15555
CAUTION:
Pressing the center section of the fan can damage the blades. Press only the outer edge of the fan.
Installing the component
1.
Align the guidepost on the new fan with the power supply connector (1).
1
3
2
3
15556
2.
Slide the replacement fan into the fan base (2) until the tabs snap into place (3).
Verifying proper operation
After replacing the fan module, verify that:
• The fan starts operating immediately.
• The fan LED is On.
• No new error messages are displayed on the array controller LCD panel.
maintenance and service guide 89
Replacing the SCSI I/O module
CAUTION:
The SCSI I/O module with an integrated EMU is not hot-pluggable. Before replacing the module, all I/O from the servers must be stopped and the MSA must be powered down.
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
Verifying component failure
Before replacing the SCSI I/O module:
• Verify that the module status LED is not illuminated or is flashing amber.
• Check the array controller LCD display panel for error messages and take appropriate action.
Removing the component
1.
Review all warnings, cautions, and preparation procedures as detailed in
.
NOTE:
Before removing the SCSI I/O module, label all cables. This ensures their reconnection in the correct configuration.
2.
Disconnect all SCSI cables from the SCSI I/O module.
3.
Press down on the SCSI I/O module latch (1) and pull the SCSI I/O module out of the enclosure (2).
1
2
1 5 559
90 Customer replaceable components
Installing the component
1.
Slide the replacement SCSI I/O module into the bay until it clicks into place.
15560
2.
Reconnect all SCSI cables.
NOTE:
Ensure that all of the SCSI cable connectors are fastened tightly.
Verifying proper operation
After replacing the failed SCSI I/O module, verify that:
• The module status LED is solid green.
• No new error messages are displayed on the array controller LCD panel.
Replacing the power button module
CAUTION:
The power button module is not hot-pluggable. Before replacing the module, all I/O from the servers must be stopped and the MSA must be powered down.
Before you begin
CAUTION:
• Before removing a component or blanking panel from an operational device, make sure that you have the replacement part available. Removing a component or blank impacts the airflow and cooling ability of the device. To avoid possible overheating, insert the new or replacement component within one or two minutes. If the internal temperature exceeds acceptable limits, the device may overheat and automatically shut down or restart.
• Parts can be damaged by electrostatic discharge. Use proper anti-static protection.
maintenance and service guide 91
Verifying component failure
Before replacing the power button module:
• Verify that the module status LED is not illuminated or is flashing amber.
• Check the array controller LCD display panel for error messages and take appropriate action.
Removing the component
1.
Review all warnings, cautions, and preparation procedures as detailed in
.
2.
Stop all access to and remove power from the MSA. For instructions, see
NOTE:
Before disconnecting any cables, label them so that they can be reconnected to the same connectors when the power switch assembly replacement is complete.
3.
Disconnect the power cables from the MSA.
4.
Disconnect the Fibre Channel cables from the MSA.
5.
Disconnect the SCSI cables from the MSA.
6.
Remove the hard drives in slots 10 through 14, making sure to carefully label each hard drive as it is removed.
CAUTION:
To prevent data loss, each hard drive must be installed in the same slot from which it was removed.
7.
Remove the MSA from the rack.
8.
Remove module:
a. Using a flat-head screwdriver, press the module’s plastic latch behind the front bezel down (1) while pulling the front module lightly with your other hand.
b. When the top plastic clip has cleared the sheet metal lip of the shelf, move the flat-head screwdriver to the lower plastic clip and press up (1).
c. Pull the module out of the chasiss (2).
1
2
15571
1
92 Customer replaceable components
Installing the component
1.
Slide the replacement power button module into the bay until it clicks into place.
2.
Reinstall all hard drives in slots 10–14.
CAUTION:
To prevent data loss, each hard drive must be installed in the same slot from which is was removed.
3.
Reinstall the MSA in the rack.
4.
Reconnect he SCSI, Fibre Channel, and power cables.
5.
Apply power to the MSA as instructed in
.
Verifying proper operation
After replacing the failed power button module, verify that:
• The module status LED is solid green.
• No new error messages are displayed on the array controller LCD panel.
Replacing the MSA1000 chassis
In the event of a backplane board failure, a new chassis must be ordered. All original component parts of the MSA can be reinstalled in their respective locations on the new backplane. The parts that will be removed from the old chassis and then reinstalled in the new chassis include:
• Controllers or controller blank
• Hard drives or blanks
• Power button module
• Fibre Channel I/O modules or interconnect blank
• MSA SAN Switch 2/8 (if installed on previous system)
• MSA Hub 2/3 (if installed on previous system)
• SCSI I/O module
• Power supply/fan assemblies
When finished, write the serial number of the original chassis (and MSA SAN Switch 2/8 and MSA
Hub 2/3) on the label of the replacement chassis.
maintenance and service guide 93
94 Customer replaceable components
7 Enclosure and hard drive migrations
This section describes the following:
• Adding a new storage enclosure
• Migrating existing enclosures
• Moving hard drives or arrays
NOTE:
For the most up-to-date information on supported enclosures, see the MSA website.
Adding a new storage enclosure
New storage enclosures with unconfigured hard drives are hot-pluggable. Perform the following steps to attach and install a new enclosure to an existing MSA:
1.
Install the new storage enclosure in the rack. Refer to the documentation that shipped with the rack for instructions.
2.
Connect the SCSI cables to the SCSI connectors on the MSA and the storage enclosure.
3.
Connect the power cords to the power supplies at the rear of the enclosure.
4.
Power on the enclosure.
5.
Configure new storage with the ACU or the CLI. Verify that additional storage is identified through the utility. For instructions, see the ACU or CLI user documents.
6.
Run the operating-system-specific administration utility to add LUNs.
7.
If necessary for your operating system, reboot the server to use the new storage.
Migrating existing storage enclosures
Even though extensive design and testing has been performed, HP recommends backing up data before migrating the enclosure to the MSA. Perform the administrative steps to defragment file systems or volumes prior to performing the backup. This allows more efficient use of your backup media and reduces the time for backup.
Perform the following steps to migrate a new enclosure to an existing MSA:
NOTE:
Only SCSI storage enclosures can be migrated; migration of SATA enclosures is not supported.
1.
After backing up the storage, schedule a convenient time to shut down the servers/applications so the storage subsystem can be turned off.
2.
Shut down the systems you are removing the storage enclosures from and the target system to which you are planning to migrate/consolidate your storage.
3.
Disconnect the SCSI cables from your HBA and storage enclosure. If necessary, move the enclosures to the new server rack using the existing rack mount hardware.
maintenance and service guide 95
4.
Attach SCSI cables to the MSA expansion SCSI connectors.
5.
Attach the SCSI cables to the expansion storage enclosures.
6.
Attach the power cords to the power supplies at the rear of the enclosures.
7.
Power on each enclosure and wait for it to complete its startup routine.
8.
Power on the MSA array controller system using the power button on the front of the system.
9.
Wait for the MSA to complete its startup routine.
10.
Power on the host servers and allow them to boot.
11.
Run the ACU or the MSA-CLI to verify that the current configuration is maintained and new volumes are identified. If the migrated volumes are not identified, power down the system and verify the connections.
12.
Run the ACU or the MSA-CLI to add LUNs. Some systems may require rebooting to use the new LUNs.
For more information on migrations, go to the HP storage website: http://www.hp.com/go/storage .
Moving hard drives or arrays
CAUTION:
Back up all data before removing hard drives or changing configurations. Failure to do so could result in permanent loss of data. Before moving hard drives and arrays, run the ACU or the MSA-CLI.
Before moving hard drives, the following conditions must be met:
• No hard drives are failed, missing, or degraded.
• No more than 32 LUNs will be configured for a controller.
• The array should be in its original configuration with no active spare hard drives.
• Capacity expansion is not running.
• Controller firmware is the latest version (recommended).
Before moving an array from one controller to another, the following additional conditions must be met:
• All hard drives in the array must be moved at the same time.
• Positions of hard drives on the destination controller must remain the same during relocation of the array.
When the appropriate conditions are met, perform the following procedure to move the hard drives:
1.
Power Off the MSA storage system as detailed in
.
2.
Move the hard drives.
3.
Power On the MSA storage system as detailed in
4.
The following message should be displayed on the LCD front panel of the controller 86 DRIVE
POSITION CHANGE DETECTED.
IMPORTANT:
If the following LCD message is displayed: 121 NO VOLUMES DETECTED, turn Off system immediately to avoid data loss, and return the hard drives to their original locations.
5.
Check the new configuration by running the ACU or MSA-CLI.
96 Enclosure and hard drive migrations
8 Capacity expansion and extension
Array expansion is the addition of physical hard drives to an array that has already been configured. The capacity of these added physical hard drives may then be added to an existing LUN on the array or configured into a new LUN.
LUN extension is the enlargement of an existing LUN after the corresponding array has undergone capacity expansion.
Expansions and extensions are performed through the ACU or MSA-CLI.
If you are using hot-pluggable hard drives, expansion can be performed online (that is, without shutting down the operating system). Online extension can only be performed if supported by the operating system.
CAUTION:
Back up all data before removing hard drives or changing configurations. Failure to do so could result in permanent loss of data.
NOTE:
When extending a LUN under Windows 2000, upgrade the LUN to Dynamic before creating a partition on that LUN. If the LUN already has a partition when it is upgraded to Dynamic, Windows may not allow LUN extension. See the Windows 2000 documentation for details about Dynamic and Basic LUNs.
NOTE:
Windows may allow only four partitions on each LUN. Additional space created may not be accessible if the four partitions per LUN limit is exceeded.
NOTE:
If you are running Windows 2000 with Microsoft Cluster Services (MSCS), LUN extensions are not recommended. MSCS requires that drives be configured as Basic in Logical Disk Manager. To take advantage of LUN extension, your hard drives would have to be configured as Dynamic when the volume is initially created. Because of the differences in requirements for the MSCS and the LUN extension feature, HP recommends that you not perform LUN extensions on storage enclosures that are part of a Microsoft Cluster.
maintenance and service guide 97
98 Capacity expansion and extension
9 Hard drive failures and faulted
LUNs
The purpose of fault-tolerant array configurations is to protect against data loss due to hard drive failure.
Each RAID configuration has inherent limitations on the number of hard drive failures that it can tolerate.
If the fault-tolerance level of a particular LUN or array configuration is exceeded, the array will be locked from any further I/O. This protection is designed to preserve the integrity of the local drive, but does require manual intervention to recover or re-enable the LUN.
Although controller firmware is designed to protect against normal hard drive failure, it is imperative that you perform the correct actions to recover from a hard drive failure without inadvertently introducing any additional hard drive failures.
Included sections:
• Recognizing hard drive failure
• Recovering from compromised fault tolerance (enabling failed LUNs)
• Best practices when replacing hard drives
Recognizing hard drive failure
LEDs on the front of each hard drive are visible from the front of the external storage unit. When a hard drive is configured as a part of an array and attached to a powered-on controller, the status of the hard drive can be determined from the illumination pattern of these LEDs.
For detailed descriptions of the various LED combinations, see
.
Other ways to determine that a hard drive has failed include the following:
• LEDs on the storage system chassis illuminate amber if failed hard drives are inside. (However, this LED also illuminates when other problems occur, such as when a fan fails, a redundant power supply fails, or the system overheats.)
• LEDs on the hard drives illuminate amber if a hard drive has failed or is a member of a faulted LUN.
• Front-panel LCD display messages list faulted LUNs and failed hard drives whenever the system is restarted, as long as the controller detects one or more good hard drives.
• ACU represents faulted LUNs and failed drives with distinctive icons.
• HP-SIM can detect failed hard drives.
• ADU lists all failed hard drives.
For more information on troubleshooting hard drive problems, see the HP ProLiant Servers Troubleshooting
Guide.
Effects of hard drive failure
When a hard drive fails, all logical drives that are in the same array are affected. Each logical drive in an array may be using a different fault-tolerance method, so each logical drive can be affected differently.
• RAID 0 configurations cannot tolerate hard drive failure. If any physical hard drive in the array fails, all non-fault-tolerant (RAID 0) LUNs in the same array also are failed.
• RAID 1 and RAID 1+0 configurations can tolerate multiple hard drive failures, as long as none of the failed hard drives are mirrored to one another.
• RAID 5 configurations can tolerate one hard drive failure.
maintenance and service guide 99
• RAID 6 configurations can tolerate simultaneous failure of two hard drives in the array.
Compromised fault tolerance
Each RAID configuration has inherent limitations on the number of physical hard drive failures that it can tolerate. If more hard drives fail than the fault-tolerance method allows, fault tolerance is compromised.
When the MSA determines that the fault tolerance of a LUN is compromised, the LUN is taken offline and subsequent I/O requests are rejected. This is designed to protect the integrity of the LUN, but does require manual intervention to recover or re-enable the LUN. You are likely to lose data, although it can sometimes be recovered.
Common causes of compromised fault tolerance include:
• More hard drives fail than the LUN can tolerate.
For example, in a RAID 5 array, if a hard drive in an array fails while another drive in the array is being rebuilt. If the array has no online spare, any logical drives in this array that are configured with
RAID 5 fault tolerance will fail.
• A SCSI cable could be broken or disconnected.
• A temporary loss of power.
For example, if both power supplies are inappropriately connected to the same power source and that power source it interrupted, fault tolerance may be compromised.
Recovering from compromised fault tolerance (enabling faulted
LUNs)
If fault tolerance is compromised, inserting replacement hard drives does not improve the condition of the logical unit. The procedure to re-enable or accept a LUN that is unresponsive is performed in the Array
Configuration Utility (ACU) or the MSA Command Line Interface (MSA-CLI).
1.
Stop all I/O activity.
2.
Turn off the system as described in
.
3.
Check for loose, dirty, broken, or bent cabling and connectors on all devices.
4.
Remove and then reinsert all hard drives and controllers.
CAUTION:
Data can be lost if the hard drives are not firmly reseated.
5.
Turn the system on as described in
NOTE:
In some cases, a marginal hard drive might work again for long enough to allow you to make copies of important files.
6.
If using the MSA LCD panel:
a. If one of the following messages are displayed on the MSA array controller LCD front panel, an issue was found with one or more configured LUNs that may result in data loss, so all of the hard drives in the LUNs have been disabled. Press the right push button to re-enable the LUNs.
02 ENABLE VOLUME <n>?
'<'=NO, '>'=YES
04 ENABLE VOLUMES ? '<'=NO, '>'=YES
100 Hard drive failures and faulted LUNs
b. Make copies of important data, if possible.
c. Replace any failed hard drives and allow the Automatic Data Recovery (ADR) process to rebuild the data onto replacement drives.
d. After failed hard drives have been replaced, fault tolerance may again be compromised. If so, power cycle the system, and if the #02 or #04 ENABLE VOLUME LCD message is displayed, press the right push button to re-enable the LUNs.
7.
If using the ACU:
a. Open the ACU and highlight the faulted LUN (shown with a red drive symbol.)
b. Select Re-enable Failed Logical Drive.
c. Repeat step a and b for each faulted LUN.
d. Save the configuration and then exit the ACU.
8.
If using the MSA-CLI:
a. Open the MSA-CLI and enter the show units command to display information about all of the LUNs associated with the MSA.
b. Enter accept units to enable all faulted LUNs.
c. Enter show units to verify the status of the LUNs.
d. Exit the MSA-CLI.
9.
Remember that data loss may have occurred and data on the LUN is suspect.
Best practices when replacing hard drives
Before replacing a degraded hard drive consider the following:
• Open HP-SIM and inspect the Error Counter window for each physical drive in the same array to confirm that no other drives have any errors. For details, see the HP-SIM documentation on the
Management CD.
• Be sure that the array has a current, valid backup.
• Use replacement drives that have a capacity at least as great as that of the smallest drive in the array.
The controller immediately fails drives that have insufficient capacity.
• In systems that use external storage enclosures, be sure that the server is the first unit to be powered down and the last to be powered back up. Taking this precaution ensures that the system does not erroneously mark the drives as failed when the server is powered up.
• When a hot-pluggable hard drive is inserted, all disk activity on the array is paused while the new hard drive is spinning up (approximately 10 seconds). If the hard drive is inserted while power is on, in a fault-tolerant configuration, data recovery onto the replacement hard drive begins automatically
(indicated by the blinking online LED).
• Sometimes, a hard drive that has previously been failed by the controller may seem to be operational after the system is power-cycled, or (for a hot-pluggable drive) after the hard drive has been removed and reinserted. However, continued use of such marginal hard drives may eventually result in data loss. Replace marginal hard drives as soon as possible.
• Back up all data before removing hard drives or changing configurations. Failure to do so could result in permanent loss of data.
• Remove only hard drives that have been failed or marked as degraded by the controller.
To minimize the likelihood of fatal system errors, take these precautions when removing failed drives:
• Do not remove a degraded hard drive if any other member of the array is offline (the online LED is off).
Exceptions:
• When RAID 1+0 is used, drives are mirrored in pairs. Several drives can be in a failed condition simultaneously (and they can all be replaced simultaneously) without data loss, as long as no two failed drives belong to the same mirrored pair.
maintenance and service guide 101
• When RAID 6 (ADG) is used, two drives can fail simultaneously (and be replaced simultaneously) without data loss.
• If the offline drive is a spare, the degraded drive can be replaced.
• Do not remove a failed second hard drive from an array until the first failed or missing hard drive has been replaced and the rebuild process is complete. (When the rebuild is complete, the online LED on the front of the hard drive stops blinking.)
Exceptions:
• In RAID 6 (ADG) configurations, any two drives in the array can be replaced simultaneously.
• In RAID1+0 configurations, any drives that are not mirrored to other removed or failed drives can be simultaneously replaced offline without data loss.
Automatic data recovery (rebuild)
When you replace a hard drive in an array, the controller uses the fault-tolerance information on the remaining drives in the array to reconstruct the missing data (the data that was originally on the replaced drive) and write it to the replacement drive. This process is called automatic data recovery, or rebuild. If fault tolerance is compromised, this data cannot be reconstructed and is likely to be permanently lost.
If another hard drive in the array fails while fault tolerance is unavailable during rebuild, a fatal system error may occur, and all data on the array is then lost. In exceptional cases, however, failure of another drive need not lead to a fatal system error. These exceptions include:
• Failure after activation of a spare drive.
• Failure of a drive that is not mirrored to any other failed drives (in a RAID 1+0 configuration).
• Failure of a second drive in a RAID ADG configuration.
Time required for a rebuild
The time required for a rebuild varies considerably, depending on several factors:
• The priority that the rebuild is given over normal I/O operations (you can change the priority setting through the Array Configuration Utility (ACU) or MSA Command Line Interface (MSA-CLI).
• The amount of I/O activity during the rebuild operation
• The rotational speed of the hard drives
• The availability of drive cache
• The brand, model, and age of the drives
• The amount of unused capacity on the drives
• The number of drives in the array (for RAID 5 and RAID ADG)
Allow approximately 15 minutes per gigabyte for the rebuild process to be completed. This figure is conservative, and newer drive models usually require less time to rebuild.
System performance is affected during the rebuild, and the system is unprotected against further drive failure until the rebuild has finished. Therefore, replace drives during periods of low activity when possible.
CAUTION:
If the Online LED of the replacement drive stops blinking and the amber Fault LED glows, or if other drive
LEDs in the array go out, the replacement drive has failed and is producing unrecoverable disk errors.
Remove and replace the failed replacement drive.
When automatic data recovery has finished, the Online LED of the replacement drive stops blinking and begins to glow steadily.
If ADR process aborts, restart the storage system and allow ADR to begin again. If ADR fails again, back up all data on the system, do a surface analysis (using your diagnostics utility), and restore the data from backup.
102 Hard drive failures and faulted LUNs
Failure of another drive during rebuild
If a non-correctable read error occurs on another physical drive in the array during the rebuild process, the Online LED of the replacement drive stops blinking and the rebuild abnormally terminates.
If this situation occurs, restart the server and the storage system. The system may temporarily become operational long enough to allow recovery of unsaved data. In any case, locate the faulty drive, replace it, and restore data from backup.
maintenance and service guide 103
104 Hard drive failures and faulted LUNs
10 Array controller firmware
Each array controller contains Read-Only Memory (ROM), which holds the firmware that operates the controller. In dual-controller configurations, the two controllers must execute the same firmware version.
Included in this section:
• Determining the currently-installed firmware version
• Updating controller firmware
• Recovering corrupted firmware
NOTE:
After updating MSA controller firmware, be sure to check the status of the MSA for unexpected issues.
Verify the status of the connections, defined profile types, redundancy settings, and storage configuration.
Determining the currently installed firmware version
To determine the firmware version currently running on a controller, do one of the following:
• On the MSA controller LCD panel, use the arrow keys to scroll backwards through the messages until the ARRAY CONTROLLER FIRMWARE VER <version> message is displayed.
• Each time the MSA controller is restarted, view the first message that displays the firmware version.
• In the CLI, use the SHOW VERSION command.
Updating controller firmware
Because the MSA can operate in a variety of operating system environments, several updating methods are available. To perform an update, obtain the following items from the MSA website:
• Controller firmware (on the Software, Firmware & Drivers page.)
• Firmware updating guide (on the Technical Documents page.)
Cloning controller firmware
NOTE:
Cloning is possible only in dual-controller configurations.
Each time a system with two controllers is powered on or restarted, or if a second controller is hot-plugged into a single-controller configuration, the firmware versions on the controllers are compared. If the firmware versions on the two controllers are different, the array controller LCD panel prompts to clone the firmware from one controller to the other, so that they have the same version.
The determination as to which firmware version is used is based on the following criteria:
• If the MSA is being powered up with both controllers inserted, then the most recent version of firmware is used regardless of which controller it resides on.
• If the MSA is already operating and an optional controller is hot-plugged, then the version of firmware that is on the original (non-hot-plugged) controller is used regardless of its version. This ensures that any host-initiated I/O to the controller is not interrupted.
maintenance and service guide 105
If the firmware version on the two controllers is not the same, the following prompt is displayed in the controller LCD panel: CLONE FIRMWARE ? ‘<‘ = NO, ‘>' = YES
If > is pressed or a response is not made to the prompt within 60 seconds, the following messages are displayed on the LCD panel while firmware is copied from the active controller to the standby controller and the standby controller is automatically restarted:
ROM CLONING STARTED
ARRAY CONTROLLER RESTARTING
STARTUP COMPLETE
The two controllers should now operate in redundant mode.
NOTE:
There is the possibility that a specific version of firmware may not be compatible with certain hardware revisions of a controller. In this scenario, the firmware on the two controllers is compared, and the version that is compatible with both controllers is copied to the controller with the incompatible firmware version.
However, if the controller that is updated is already operating and processing I/O, it is not reset. The
MSA does not enter redundant operation and an appropriate message is shown on the display. After the
MSA has been shut down and powered back on, the controllers are then be able to enter redundant operation. On a subsequent power cycle, both controllers enter redundant mode.
Recovering corrupted firmware
If the controller detects a firmware corruption, the following message is displayed on the LCD panel:
ERROR: ROM CORRUPT
SEND IMG VIA XMODEM
To recover the controller, you must obtain a current firmware image and send it to the controller using a serial connection.
1.
Go to the MSA website and obtain the latest controller firmware.
NOTE:
If you are not yet registered, select the option to receive e-mail notifications, advisories, and support alerts about MSA system hardware, firmware, drivers, and software components.
This alert notification system is a one-way broadcasting method used to distribute important notices about HP products. Information about your MSA is not requested when subscribing to this service.
2.
Establish a serial connection to the affected controller:
• Use the custom CLI configuration cable shipped with the MSA.
• Use a terminal emulator program that supports the Xmodem protocol, such as HyperTerminal.
• Use the following emulator connection settings:
• Bits per second: 19200
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: None
A blank emulator window is displayed—no CLI prompt is displayed.
3.
Using the emulator transfer (or send file) command, send the firmware to the controller.
106 Array controller firmware
The following instructions and examples use HyperTerminal. For more information, see user documentation for your emulator program.
a.
On the menu bar at the top of the HyperTerminal window, select Transfer > Send File.
b.
Click Browse and navigate to the location of the firmware image obtained in
c.
Expand the Protocol drop-down box and select 1K XModem.
d.
Click Send.
A status window is displayed.
4.
Wait for the transfer process to complete.
NOTE:
This process may take up to 15 minutes. Do not interrupt this process.
5.
Wait for the controller to automatically restart.
maintenance and service guide 107
6.
In dual-controller configurations only, if the newly installed firmware on the recovered controller differs from the firmware on the active controller, the CLONE FIRMWARE LCD message is displayed.
See
108 Array controller firmware
11 SCSI hard drive firmware
SCSI hard drive firmware updates are performed from the bootable ProLiant Firmware Maintenance CD and are required only when the following message is displayed on the MSA controller LCD panel:
85 BAD DRIVE FRMWARE BOX <n> BAY <n>
CAUTION:
This update procedure must be performed during a scheduled maintenance window.
1.
Obtain the ISO image for the ProLiant Firmware Maintenance CD from the following website: http://www.hp.com/support/proliantstorage . Then, burn the image onto a bootable CD using a standard CD-ROM burning utility. Do not simply copy the ISO file to a blank CD.
NOTE:
If the latest Firmware Maintenance CD does not include the latest release of hard drive firmware contained in a Smart Component, the CD can be used in combination with the latest individual Smart
Component package to perform the update.
2.
Insert the CD into the CD-ROM hard drive of a ProLiant server with access to the MSA.
3.
Following standard precautions, remove power from the server. For instructions, see
4.
Reapply power to the server.
5.
Allow the server to boot to the Firmware Maintenance CD, and then follow the onscreen instructions to upgrade the firmware on the hard drives.
maintenance and service guide 109
110 SCSI hard drive firmware
A Regulatory compliance and safety
Regulatory compliance
Federal Communications Commission notice
Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio
Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (i.e., personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user.
The rating label on the device shows which class (A or B) the equipment falls into. Class B devices have an FCC logo or FCC ID on the label. Class A devices do not have an FCC logo or FCC ID on the label.
Once the class of the device is determined, refer to the following corresponding statement.
Class A equipment
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.
Class B equipment
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected.
• Consult the dealer or an experienced radio or television technician for help.
maintenance and service guide 111
Declaration of conformity for products marked with the FCC logo, United States only
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For questions regarding your product, visit http://www.hp.com
For questions regarding this FCC declaration, contact us by mail or telephone:
• Hewlett-Packard Company P.O. Box 692000, Mailstop 510101 Houston, Texas 77269-2000
• 1-281-514-3333
To identify this product, refer to the part, Regulatory Model Number, or product number found on the product.
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user's authority to operate the equipment.
Cables
Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.
Regulatory compliance identification numbers
For the purpose of regulatory compliance certifications and identification, your product has been assigned a unique Regulatory Model Number. The RMN can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this RMN. The Regulatory Model Number should not be confused with the marketing name or model number of the product.
Regulatory compliance label location
The Regulatory Compliance label for the MSA is located on the right side of the chassis.
International notices and statements
Canadian notice (avis Canadien)
Class A equipment
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
Class B equipment
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
112 Regulatory compliance and safety
European Union notice
Products bearing the CE marking comply with the EMC Directive (89/336/EEC) and the Low Voltage
Directive (73/23/EEC) issued by the Commission of the European Community and if this product has telecommunication functionality, the R&TTE Directive (1999/5/EC).
Compliance with these directives implies conformity to the following European Norms (in parentheses are the equivalent international standards and regulations):
• EN55022 (CISPR 22) - Electromagnetic Interference
• EN55024 (IEC61000-4-2, IEC61000-4-3, IEC61000-4- 4, IEC61000-4-5, IEC61000-4-6,
IEC61000-4-8, IEC61000-4-11) - Electromagnetic Immunity
• Power Quality:
• EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics
• EN60950 (IEC60950) - Product Safety
• EN61000-3-3 (IEC61000-3-3) - Power Line Flicker
• Also approved under UL 60950/CSA C22.2 No. 60950-00, Safety of Information Technology
Equipment.
BSMI notice
Japanese notice
maintenance and service guide 113
Korean notices
Safety notices
Battery replacement notice
Your computer is equipped with a lithium manganese dioxide, a vanadium pentoxide, or an alkaline internal battery or battery pack. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized reseller or HP authorized service provider.
WARNING!
Your computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. There is risk of fire and burns if the battery pack is not properly handled. To reduce the risk of personal injury:
• Do not attempt to recharge the battery.
• Do not expose to temperatures higher than 60˚C.
• Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
• Replace only with the HP spare part designated for this product.
Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, please use the public collection system or return them to HP, an authorized HP Partner, or their agents.
For more information about battery replacement or proper disposal, contact an HP authorized reseller or service provider.
114 Regulatory compliance and safety
Taiwan battery recycling notice
The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal.
Power cords
The power cord set must meet the requirements for use in the country where the product was purchased.
If the product is to be used in another country, purchase a power cord that is approved for use in that country.
The power cord must be rated for the product and for the voltage and current marked on the product electrical ratings label. The voltage and current rating of the cord should be greater than the voltage and current rating marked on the product. In addition, the diameter of the wire must be a minimum of
1.00 mm 2 or 18 AWG, and the length of the cord must be between 1.8 m (6 ft) and 3.6 m (12 ft). If you have questions about the type of power cord to use, contact an HP authorized service provider.
NOTE:
Route power cords so that they will not be walked on and cannot be pinched by items placed upon or against them. Pay particular attention to the plug, electrical outlet, and the point where the cords exit from the product.
Japanese power cord notice
Electrostatic discharge
To prevent damage to the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.
Preventing electrostatic damage
To prevent electrostatic damage, observe the following precautions:
• Avoid hand contact by transporting and storing products in static-safe containers.
• Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.
• Place parts on a grounded surface before removing them from their containers.
• Avoid touching pins, leads, or circuitry.
• Always be properly grounded when touching a static-sensitive component or assembly (see
“
”).
Grounding methods
There are several methods for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts: maintenance and service guide 115
• Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis.
Wrist straps are flexible straps with a minimum of 1 megohm (±10 percent) resistance in the ground cords. To provide proper ground, wear the strap snug against the skin.
• Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.
• Use conductive field service tools.
• Use a portable field service kit with a folding static-dissipating work mat.
If you do not have any of the suggested equipment for proper grounding, have an HP authorized reseller install the part.
NOTE:
For more information on static electricity, or assistance with product installation, contact your HP authorized reseller.
116 Regulatory compliance and safety
Index
A
AC circuit overload, warning
accumulators
ADU, described
alkaline battery warning
audience
Avis Canadien, regulatory compliance notice ,
B backplane, replacement
batteries recycling or disposal
replacement notice
warning
Taiwan EPA recycling and disposal
warnings
boot straps, using
BSMI, regulatory compliance notice
C cables distances supported
FCC compliance statement
multi-mode
option kits
part numbers
shielded
cache battery pack, replacing
module, replacing
Canada, regulatory compliance notice
cautions thermal failure
chassis replacement
chassis specifications dimensions
input voltage requirements
maximum wet-bulb temperature
relative humidity
server temperature
weight
Class A equipment, Canadian compliance statement
Class B equipment, Canadian compliance statement
cloning of firmware between controllers
Command Line Interface, described
component level repairs, warning
controller display messages
ejector levers
failure
latches
removing
replacing
securing
controller display components
error messages
informational messages
message types
operating modes
user input messages
controller display messages access control conflict detected
access control resources exceeded
array controller disabled
array controller overheated
array controller overheating
array controller restarting
array controller temperature ok
bad hard drive firmware box
bad SCSI bus mode non-LVD device found ,
bad scsi target
beacon off
beacon on
cache batteries low, recharging
cache data lost battery dead
cache disabled no configuration
cache error
cache hardware batteries
cache hardware enabled
cache hardware failed and disabled
cache hardware temporarily disabled
cache module # MB
chassis nvram contents corrupted
clone firmware
cloning refused system halted
configured volumes
controller too old not supported
critical lockup detected
dual cache module size mismatch
EMU flash done
EMU flash failed
EMU flash started
enable volume
enable volumes
fibre device hardware failure
fibre subsystem hardware failure
maintenance and service guide 117
118 fibre subsystem link failure
fibre subsystem link OK
fibre switch hardware failure
firmware flash done
firmware flash done on box #<n>
firmware flash failed
firmware flash failed on box #<n>
firmware flash started
firmware flash started on box #<n>
firmware version
FW version is not supported
hard drive failure box
hard drive hot added box bay
hard drive hot removed box bay
hard drive position change detected
hard drive position charge invalid
I2C read failure
I2C write failure
initializing fibre subsystem
initializing PCI subsystem
initializing redundancy support
initializing SCSI subsystem
invalid config box
invalid SCSI cabling
MSA1000 active controller
MSA1000 standby controller
new volume(s) detected
no cache module found
no volumes detected
non-compaq hard drive
obsolete cache data deleted
online upgrade complete
online upgrade flashing done
online upgrade flashing failed
online upgrade flashing firmware
online upgrade flashing started
online upgrade incomplete
online upgrade redundancy halted
online upgrade restarting system
PCI bridge ASIC self-test failure
PCI subsystem hardware failure
persistent mem disabled
persistent mem enabled
pilot 2 contrlr not supported
recovery ROM autoflash done
recovery ROM autoflash failed
recovery ROM autoflash started
redundancy active active controller
redundancy active standby controller
redundancy failed cache Dimms mismatch ,
redundancy failed cache size mismatch
redundancy failed firmware lockup
redundancy failed hardware failure
redundancy failed I/O request error
redundancy failed mismatch firmware
redundancy failed mismatch hardware
redundancy failed no second controller
redundancy failed out-of-memory
redundancy failed PCI Bus error
redundancy halted expand active
redundancy halted firmware cloned
remove other controller now
replacement hard drive found box
restarting system
ROM cloning done
ROM cloning failed
ROM cloning started
scanning SCSI subsystem
smart hard drive alert box
spares cleared
startup complete
storage box EMU not responding
storage box EMU version
storage box fan degraded
storage box fan failed
storage box fan hot inserted
storage box fan hot removed
storage box fan OK
storage box hot added
storage box hot removed
storage box overheated
storage box overheating
storage box power supply added
storage box power supply failed
storage box power supply ok
storage box power supply removed
storage box temperature ok
system halted for cache error
system name
too many volumes detected
uncorrected ECC memory
unknown I/O module detected
valid cache data found at power up
volume expansion disabled
volume expansion failure
volume initializing parity
volume media exchanged
volume rebuild failure
volume state deleted
volume state disabled
volume state expansion active
volume state failed
volume state interim recovery
volume state missing drives
volume state ok
volume state rebuilding
volume state waiting to expand
volume state waiting to rebuild
volume state wrong hard drive replaced
conventions document
text symbols
cord. See power cord
current rating
customer self repair
D declaration of conformity
device preparation removing power
warnings and precautions
device, unloading from pallet
diagnostic tools
disposal, battery
dissipating floor mats
document conventions
prerequisites
related documentation
documentation
HP website
providing feedback
E electrostatic damage prevention
electrostatic discharge See ESD
electrostatic discharge See ESD
electrostatic sensitive parts handling
packaging
storing
transporting
enclosure expansion
ACU
ACU-XE
adding enclosures to existing MSA
attaching SCSI cables
rack considerations
recommended procedures
error messages access control conflict detected
access control resources exceeded
array controller disabled
array controller overheated
array controller overheating
bad hard drive firmware box
bad SCSI bus mode non-LVD device found ,
bad scsi target
cache data lost battery dead
cache hardware batteries
cache hardware failed and disabled
chassis nvram contents corrupted
cloning refused system halted
controller too old not supported
critical lockup detected
dual cache module size mismatch
EMU flash failed
fibre device hardware failure
fibre subsystem hardware failure
fibre subsystem link failure
fibre switch hardware failure
firmware flash failed
firmware flash failed on box #
fw version is not supported
hard drive failure box
I2C read failure
I2C write failure
invalid config box 3<n>, bay<n>
invalid SCSI cabling
no cache module found
online upgrade flashing failed
online upgrade incomplete
PCI bridge ASIC self-test failure
PCI subsystem hardware failure
pilot 2 contrlr not supported
recovery ROM autoflash failed
redundancy failed cache Dimms mismatch ,
redundancy failed cache size mismatch
redundancy failed firmware lockup
redundancy failed hardware failure
redundancy failed I/O request error
redundancy failed mismatch firmware
redundancy failed mismatch hardware
redundancy failed no second controller
redundancy failed out-of-memory
redundancy failed PCI Bus error
remove other controller now
ROM cloning failed
storage box EMU not responding
storage box fan degraded
storage box fan failed
storage box overheated
storage box overheating
storage box power supply failed
system halted for cache error
too many volumes detected
uncorrected ECC memory
unknown I/O module detected
volume expansion failure
volume rebuild failure
volume state disabled
volume state failed
volume state missing drives
volume state wrong hard drive replaced
ESD (electrostatic discharge) obtaining additional information
precautions
preventing
prevention measures
storing products
transporting products
types of damage from
European Union, regulatory compliance notice ,
F fault tolerance, removing hard drives
FCC (Federal Communications Commission)
Class A Equipment, compliance notice
Class B Equipment, compliance notice
declaration of conformity
modifications
notice
maintenance and service guide 119
Federal Communications Commission. See
FCC
Fibre Channel I/O module replacing
figures
LEDs controller
fibre channel 1/0 module
firmware cloning
cloning in redundant configurations
updating
floor mats, dissipating
G
German noise declaration
ground strap specifications
grounding methods
methods
procedures
straps, wearing
suggested equipment for
H hard drive blank, removing
blank, replacing
ejector levers
latches
LEDs amber
recognizing
reconstructing
removing
removing in fault-tolerant systems
securing
hard drive firmware updating
hazardous conditions symbols on equipment
heel straps, using
help obtaining
hot-pluggable parts, MSA
HP address for
FCC questions
series number
technical support
telephone number
FCC questions
I
I/O EMU removing
IEC EMC, worldwide regulatory compliance notice
illustrated parts breakdown
informational messages array controller restarting
array controller temperature ok
beacon off
beacon on
cache batteries low, recharging
cache disabled no configuration
cache hardware enabled
cache hardware temporarily disabled
cache module # MB
configured volumes
EMU flash done
EMU flash started
fibre subsystem link ok
firmware flash done
firmware flash done on box #
firmware flash started
firmware flash started on box #
firmware version
hard drive hot added box bay
hard drive hot removed box bay
hard drive position change detected
hard drive position charge invalid
initializing fibre subsystem
initializing PCI subsystem
initializing redundancy support
initializing SCSI subsystem
initializing subsystem
MSA1000 active controller
MSA1000 standby controller
new volume(s) detected
no volumes detected
non-compaq hard drive
obsolete cache data deleted
online upgrade complete
online upgrade flashing done
online upgrade flashing firmware
online upgrade flashing started
online upgrade redundancy halted
online upgrade restarting system
persistent mem disabled
persistent mem enabled
recovery ROM autoflash done
recovery ROM autoflash started
redundancy active active controller
redundancy active standby controller
redundancy halted expand active
redundancy halted firmware cloned
replacement hard drive found box
restarting system
ROM cloning done
ROM cloning started
scanning SCSI subsystem
smart hard drive alert box
spares cleared
startup complete
storage box EMU version
120
storage box fan hot inserted
storage box fan hot removed
storage box fan OK
storage box hot added
storage box hot removed
storage box power supply added
storage box power supply ok
storage box power supply removed
storage box temperature ok
system name
valid cache data found at power up
volume expansion disabled
volume initializing parity
volume media exchanged
volume state deleted
volume state expansion active
volume state interim recovery
volume state ok
volume state rebuilding
volume state waiting to expand
volume state waiting to rebuild
interconnect blanks, replacing
J
Japan, regulatory compliance notice
K
Korean, regulatory compliance notice
L labels, symbols on equipment
latches, hard drive
LEDs controller
enclosure status
fibre channel I/O module
hard drive access
hard drive tray
hard drive, operational
I/O EMU
online
power supplies/fan assemblies
SCSI I/O module
lithium battery
loading rack, warning
M
Modular Smart Array 1000 illustrated parts breakdown and spare parts list
MSA controller replacing
updating the firmware
verifying failure
MSA1000 controller LEDs
N noise declaration, German
non-hot-pluggable devices, removing
non-hot-pluggable parts, MSA
P parts hot-pluggable, MSA
non-hot-pluggable, MSA
proper handling
storing
transporting
power connecting
powering down
switch, position
system
power button servicing
power cord compliance notice
current rating
MSA
replacement
set
voltage rating
power cords
disconnecting
power supplies specifications
weight
power supplies/fan assemblies
LEDs
removing power from
preparation procedures
prerequisites
preventing electrostatic damage
Q qualified service personnel, warning
R rack stability, warning
recycling, battery
recycling, Taiwan EPA battery
maintenance and service guide 121
regulatory compliance information number
notices
BSMI
Canada
Class A
Class B
European Union
HP series number
IEC EMC statement, worldwide
Japan
Korean
modifications
shielded cables
related documentation
replacing a power cord
RFI/EMI connector hoods
ROM cloning
S
SCSI I/O module
LEDs
SCSI Module with Integrated Environmental
Monitoring Unit See I/O EMU
series number, regulatory compliance
spare parts list
specifications, overview
standby
static electricity
static-dissipating work mat
static-safe containers storing products
transporting products
static-sensitive devices
straps, ground boot
heel
toe
Subscriber’s Choice, HP
switch power
symbols on equipment
symbols in text
system preventing electrostatic discharge to
Systems Insight Manager description
T
Taiwan EPA battery recycling and disposal ,
technical support
HP
service locator website
telephone numbers
FCC questions
text symbols
thermal failure, caution
toe straps, using
tools conductive type
required for servicing
type recommended
U updating
MSA controller firmware
hard drive firmware
user input messages cache error
clone firmware
enable volume
enable volumes
V views, front and rear
voltage compliance rating
W warnings
AC circuit overload
alkaline batteries
battery replacement
component level repairs
loading rack
rack stability
websites customer self repair
HP
HP Subscriber’s Choice for Business
product manuals
work area recommendations
work mat, static-dissipating
wrist strap using
wrist straps specifications
using
122
Download
Advertisement
Key features
Modular design
Customer self repair
Array Configuration Utility (ACU)
Array Diagnostics Utility (ADU)
HP Systems Insight Manager (HP-SIM)
HP Storage Management Initiative Specification (SMIS)
Frequently asked questions
This is a storage system that provides a variety of features to help you manage your data.
The HP StorageWorks 1000 Modular Smart Array is supported by a variety of tools including the Array Configuration Utility (ACU), Array Diagnostics Utility (ADU), HP Systems Insight Manager (HP-SIM), and HP Storage Management Initiative Specification (SMIS).
Customer self repair allows you to repair your StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience.