advertisement
▼
Scroll to page 2
of 7
Energy Management Power Analyzer Type WM14-DIN “Basic Version” • Optional dual pulse output • Alarms (visual only) VLN, An • Optional galvanically insulated measuring inputs • Class 1 (active energy) • Class 2 (reactive energy) • Accuracy ±0.5 F.S. (current/voltage) • Power analyzer • Display of instantaneous variables: 3x3 digit • Display of energies: 8+1 digit • System variables and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz • Amax, Admd max, Wdmd max indication • Energy measurements: kWh and kvarh • Hour counter (5+2 DGT) • TRMS meas. of distorted sine waves (voltages/currents) • Power supply: 24V, 48V, 115V, 230V, 50-60Hz; 18 to 60VDC • Protection degree (front): IP40 • Front dimensions: 107.8x90mm • Optional RS422/485 serial port Product Description How to order 3-phase power analyzer with built-in programming keypad. Particularly recommended for displaying the main electrical variables. Housing for DIN-rail mount- Model Range code System Power supply Option ing, (front) protection degree IP40, and optional RS485 serial port or dual pulse output. Parameters programmable by means of CptBSoft. How to order Range codes System Power supply AV5: 3: A: 1-2-3-phase, balanced/unbalanced load,with or without neutral B: C: D: 3: Input specifications Rated inputs Current “X-S options” Current “SG-PG options” Voltage Accuracy (display, RS485) (@25°C ±5°C, R.H. ≤60%) Current Neutral current Phase-phase voltage Phase-neutral voltage Active and Apparent power, Reactive power CptBSoft CptBSoft (compatible only with S or SG options): software to program the working parameters of the power analyzer and to read the energy and the instantaneous variables. Type Selection 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 V AV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 V VL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6A WM14-DIN AV5 3 D PGX 3 (non insulated each other) 3 (insulated each other) 4 with CT=1 and VT=1 AV5: 1150W-VA-var, FS:230VLN, 400VLL; AV6: 285W-VA-var, FS:57VLN, 100VLL 0.25 to 6A: ±(0.5% FS +1DGT) 0.03A to 0.25A: ±(0.5%FS+7DGT) 0.25 to 6A: ±(1.5% FS +1DGT) 0.09A to 0.25A: ±(0.5%FS+7DGT) ±(1.5% FS +1 DGT) ±(0.5% FS + 1 DGT) 0.25 to 6A: ±(1% FS +1DGT); 0.03A to 0.25A: ±(1% FS+5DGT) 0.25 to 6A: ±(2% FS +1DGT); 0.03A to 0.25A: ±(2% FS+5DGT) Specifications are subject to change without notice 24VAC -15+10%, 50-60Hz 48VAC -15+10%, 50-60Hz 115VAC -15+10%, 50-60Hz 230VAC -15+10%, 50-60Hz 18 to 60VDC (not available in case of SG or PG options) Active energy “X-S option” Reactive energy “X-S option” Active energy “SG-PG opt.” Reactive energy “SG-PG opt.” Frequency Additional errors Humidity Temperature drift Sampling rate Display refresh time Display Type Read-out for instant. var. Read-out for energies Read-out for hour counter WM14-DINPDS070905 Options X: S: SG: PG: None RS485 port RS485+galvanic insulated measurig inputs Dual pulse output + galvanically insulated measuring inputs. Class 2 (start up “I”: 30mA) Class 3 (start up “I”: 30mA) Class 1 (start up “I”: 30mA) Class 2 (start up “I”: 30mA) ±0.1Hz (48 to 62Hz) ≤0.3% FS, 60% to 90% RH ≤ 200ppm/°C 1400 samples/s @ 50Hz 1700 samples/s @ 60Hz 700ms LED, 9mm 3x3 DGT 3+3+3 DGT (Max indication: 999 999 99.9) 1+3+3 DGT (Max. indication: 9 999 9.99) 1 WM14-DIN Input specifications (cont.) Measurements Coupling type Crest factor Input impedance 380/660VL-L (AV5) 120/208VL-L (AV6) Current Current, voltage, power, power factor, frequency, energy, TRMS measurement of distorted waves. Direct < 3, max 10A peak (X-S options) 1 MΩ ±5% 453 KΩ ±5% ≤ 0.02Ω Input impedance 380/660VL-L (AV5) 120/208VL-L (AV6) Current Frequency Overload protection Continuos voltage/current For 500ms: voltge/current (PG-SG options) 1 MΩ ±1% 1 MΩ ±1% ≤ 0.02Ω 48 to 62 Hz 1.2 F.S. 2 Un/36A RS485 Serial Port Specifications RS422/RS485 (on request) Type Connections Addresses Protocol Multidrop bidirectional (static and dynamic variables) 2 or 4 wires, max. distance 1200m, termination directly on the instrument 1 to 255, key-pad selectable MODBUS/JBUS Data (bidirectional) Dynamic (reading only) Static (writing only) Data format Baud-rate System, phase variables and energies All configuration parameters 1 bit di start , 8 data bit, no parity, 1 stop bit 9600 bit/s CptBSoft software: parameter programming and reading data CptBSoft Multi language software to program the working parameters of the power analyzer and to read the energies and the instantaneous variables. The program runs under Windows 95/98/98SE/2000/ NT/XP. Working mode Data access Two different working modes can be selected: - management of a local RS485 network; - management of communication from a single instrument to PC (RS232); By means of RS485 serial port. Dual pulse output Digital outputs (on request) Pulse outputs Number of outputs Number of pulses Output type 2 2 (one for kWh one for kvarh) From 0.01 to 999 in compliance with the following formula: [Psys max (kW or kvar)*pulses (pulses/kWh or kvarh)] <14400 Relay min current: 0.05A@250VAC/30VDC max current: 5A@250VAC/30VDC Pulse duration Insulation Electrical life: min 2*105 cycles Mechanical life: 5*106 cycles ≥100ms <120ms (ON) ≥100ms (OFF) According to EN622053-31 By means of relays, 4000 VRMS outputs to measuring inputs, 4000 VRMS output to supply input. Insulation between the two outputs: 1000VRMS Specifications are subject to change without notice WM14-DINPDS070905 WM14-DIN Software functions Password 1st level 2nd level System selection Transformer ratio CT VT Filter Operating range Filtering coefficient Filter action Displaying 3-phase system with neutral Numeric code of max. 3 digits; 2 protection levels of the programming data Password “0”, no protection Password from 1 to 999, all data are protected 3-phase with/without n, unbal. 3-phase balanced 3-phase ARON, unbalanced 2-phase Single phase 1 to 999 1.0 to 99.9 0 to 100% of the input display scale 1 to 16 Measurements, alarms, serial out. (fundamental var: V, A, W and their derived ones). Up to 3 variables per page Page 1: V L1, V L2, V L3 Page 2: V L12, V L23, V L31 Page 3: A L1, A L2, A L3 Page 4: A L1 dmd, A L2 dmd, A L3 dmd Alarms Reset Page 5: An, An Alarm Page 6: W L1, W L2, W L3 Page 7: PF L1, PF L2, PF L3 Page 8: var L1, var L2, var L3 Page 9: VA L1, VA L2, VA L3 Page 10: VA ∑, W ∑, var ∑ Page 11: VA dmd, W dmd, Hz Page 12: W dmd max (*) Page 13: Wh (*) Page 14: varh (*) Page 15: VL-L ∑, PF ∑, VLN Alarm Page 16: A max (*) Page 17: A dmd max (*) Page 18: hour counter (*) (*) = These variables are stored in EEPROM when the instrument is switched off Programmable, for the VL∑ and An (neutral current). Note: the alarm is only visual, by means of LED on the front of the instrument. Independent alarm (VL∑, An) max: A dmd, W dmd all energies (Wh, varh) and hour counter Power Supply Specifications Auxiliary power supply 230VAC -15 +10%, 50-60Hz 115VAC -15 +10%, 50-60Hz 48VAC -15 +10%, 50-60Hz Power consumption 24VAC -15 +10%, 50-60Hz 18 to 60VDC AC: 4.5 VA DC: 4W General Specifications Operating temperature Storage temperature Installation category Insulation (for 1 minute) 0° to +50°C (32 to 122°F) (RH < 90% non condensing) -10° to +60°C (14 to 140°F) (RH < 90% non condensing) Cat. III (IEC 60664, EN60664) 4000VAC, 500VDC between mesuring inputs and power supply. 500VAC/DC between Specifications are subject to change without notice Dielectric strength EMC Emissions WM14-DINPDS070905 mesuring inputs and RS485. 4000VAC, 500VDC between power supply and RS485 4000 VAC (for 1 min) EN50084-1 (class A) residential environment, commerce and light industry 3 WM14-DIN General Specifications (cont.) EMC (cont.) Immunity Pulse voltage (1.2/50µs) Safety standards Approvals Connections 5(6) A Max cable cross sect. area EN61000-6-2 (class A) industrial environment. EN61000-4-5 IEC60664, EN60664 CE, (cURus, CSA only “X” and “S” options) Screw-type 2.5 mm2 Housing Dimensions (WxHxD) Material Mounting Protection degree Weight 107.8 x 90 x 64.5 mm ABS self-extinguishing: UL 94 V-0 DIN-rail Front: IP40 (standard) Connections: IP20 Approx. 400 g (pack. incl.) Display pages Display variables in 3-phase systems (in a 3-phase system with neutral) No 1st variable 2nd variable 3rd variable 1 V L1 V L2 V L3 2 V L12 V L23 V L31 3 4 A L1 A L1 dmd A L2 A L2 dmd A L3 A L3 dmd 5 An AL.n 6 W L1 W L2 W L3 7 8 PF L1 var L1 PF L2 var L2 PF L3 var L3 9 10 11 VA L1 VA system VA dmd (system) VA L3 var system Hz (system) 12 13 Wh (MSD) VA L2 W system W dmd (system) W dmd MAX Wh 14 varh (MSD) varh varh (LSD) 15 V LL system AL.U PF system 16 17 18 A MAX A dmd max h Wh (LSD) Note Decimal point blinking on the right of the display dmd = demand (integration time selectable from 1 to 30 minutes) AL.n if neutral current alarm is active Decimal point blinking on the right of the display if generated power Decimal point blinking on the right of the display if generated power dmd = demand (integration time selectable from 1 to 30 minutes) Maximum sys power demand The total indication is given in max 3 groups of 3 digits. The total indication is given in max 3 groups of 3 digits. AL.U= is activated only if one of VLN is not within the set limits. max. current among the three phases max. dmd current among the three phases hour counter MSD: most significant digit LSD: least significant digit 1) Example of kWh visualization: This example is showing 15 933 453.7 kWh 4 2) Example of kvarh visualization: This example is showing 3 553 944.9 kvarh Specifications are subject to change without notice WM14-DINPDS070905 WM14-DIN Waveform of the signals that can be measured Figure B Sine wave, indented Fundamental content 10...100% Harmonic content 0...90% Frequency spectrum: 3rd to 16th harmonic Additional error: <1% FS Figure A Sine wave, undistorted Fundamental content 100% Harmonic content 0% Arms = 1.1107 | A | Figure C Sine wave, distorted Fundamental content 70...90% Harmonic content 10...30% Frequency spectrum: 3rd to 16th harmonic Additional error: <0.5% FS Accuracy kWh, accuracy (RDG) depending on the current PF=1 PF=L0.5 or C0.8 Error +2.5% +2% +1.5% +1% Class 2 +1% +1.5% +2% +2.5% PF=L0.5 or C0.8 +1.5% Class 2 0.10A (0.02In) 0.25A (0.05In) 0.25A (0.05In) 0.5A (0.1In) Error +4% +3% +2.5% +2% Class 3 0% Class 2 - 1% +2% +2.5% Class 3 -1.5% +3% +4% + 1% Class 1 0% PF=1 kvarh, accuracy (RDG) depending on the current 5A (In) 6A (Imax) sinϕ=1 5A (In) 6A (Imax) sinϕ=0.5 Class 2 accuracy limits (Active energy) 5(6A) Start-up current: 30mA 0.1A (0.02In) 0.25A (0.05In) 0.25A (0.05In) 0.5A (0.1In) 5A (In) 6A (Imax) 5A (In) 6A (Imax) Class 3 accuracy limits (Reactive energy) 5(6A) Start-up current: 30mA : this graph is only referred to instrument models with the “SG or PG” option. : this graph is only referred to instrument models with the “X or S” option. Used calculation formulas Phase variables Instantaneous effective voltage Instantaneous apparent power 3-phase active power Instantaneous reactive power 3-phase apparent power System variables Equivalent 3-phase voltage 3-phase power factor Instantaneous power factor Instantaneous effective current 3-phase reactive power Instantaneous active power Neutral current Specifications are subject to change without notice WM14-DINPDS070905 An = AL1 + AL2 + AL3 5 WM14-DIN Used calculation formulas (cont.) Energy metering Where: i = considered phase (L1, L2 or L3) P = active power Q = reactive power t1, t2 = starting and ending time points of consumption recording n = time unit ∆t = time interval between two successive power consumptions n1, n2 = starting and ending discrete time points of consumption recording Wiring diagrams CT connection 2-phase connection ARON and VT connection 3CT and 3VT connection Fig. 4 Fig. 3 Fig. 2 Fig. 1 Fig. 5 3-phase load balanced connection Fig. 6 1-phase connection NOTE: Only for “PG” and “SG” options: the current measuring inputs are galvanically insulated and therefore they can be connected to ground singly. NOTE: For all models except for “PG” or “SG” the current inputs can be connected to the lines ONLY by means of current transformers. The direct connection is not allowed. 6 Specifications are subject to change without notice WM14-DINPDS070905 WM14-DIN RS485 port connections [c] 10 10 GND T 11 T 11 RS485 RS232 RX+ 12 RX+ 12 TX+ RX- 13 RX- 13 TX- TX+ 14 TX+ 14 RX+ TX- 15 TX- 15 RX- [b] [a] PC 4-wire connection [c] 10 10 GND T 11 T 11 RS485 RS232 RX+ 12 RX+ 12 TX+ RX- 13 RX- 13 TX- TX+ 14 TX+ 14 RX+ TX- 15 TX- 15 RX- GND Fig. 8 GND Pulse 2 GND Pulse 1 [b] [a] Dual pulse output connections 21 GND PC 2-wire connection N + L - 12 6 13 7 43 14 8 15 9 Fig. 7: a-Last instrument; b-1...n Instrument c-RS485/232 serial converter Front Panel Description 1. Key-pad To program the configuration parameters and the display of the variables. S Key to enter programming and confirm selections; 1 ▲ ▲ 2 Keys to: - programme values; - select functions; - display measuring pages. 2. Display LED-type with alphanumeric indications to: - display configuration parameters; - display all the measured variables. 45mm 44mm 90mm Dimensions and Panel Cut-out 108,5mm 32,2mm 107,8mm Specifications are subject to change without notice 50,1mm 64,5mm WM14-DINPDS070905 7
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement