Eaton 9155 3Ph Site Planning Guide 8

Add to My manuals
1 Pages

advertisement

Eaton 9155 3Ph Site Planning Guide 8 | Manualzz
 POWERWARE 9155 8-15kVA UPS WITH INTEGRAL MBS
|
S1 X2
BYPASS STATIC SWITCH UPS
BYPASS INPUT X1 OUTPUT output
suppLY _ _ [) > Lu , . lu
у > > ; TO LOAD
240V 50Hz 7
> 240V 50Hz
ire | LN A > | 19 2 Wire
| a 2 Й
$2 $3
/ L RECTIFIER INVERTER Ctl
Nols, =
x = STATIC SWITCH
MAINS Г / 12” v + | a O
SUPPLY Po 3 a
415V 50Hz x — uv | В O
30 4 Wire RECTIFIER a !
INPUT Fi
EARTH PE À | | INTERNAL BATTERIES
+ | | 384VDC NOMINAL
| -- ZZ + XSLOT MODULES
--- - —-- — — — — — -— - 4 (Example Configuration Only)
| XSLOT-1 XSLOT-2
SUPPLY EITHER | | | | |
SEPARATE BYPASS INPUT BATTERY INPUT
x
o
OR INPUT BRIDGING LINKS ConnectUPS/SNMP
(Optional)
Relay Interface Adapter
(Optional)
и
LP
va
Я,
и
с
hu
|
|
||
OPTIONAL EXTERNAL
BATTERY PACK
Notes:
1. Wiring supplied by Eaton: External Battery Cabinet supplied with cables for connection to UPS
2. Wiring supplied by others: Bypass Input (or Input Bridging Links), Mains Input & Load cables
3. Battery Cable is sized to allow for side-by-side UPS & Battery Cabinets installation
4. The system must be installed on a level floor suitable for electronic equipment.
5. Ambient temperature range: 0-40C; Recommended operating range: 20-25C;
Maximum relative humidity: 95% non-condensing.
6. Minimum Clearances for ventilation & service around the UPS cabinet are:
Front, Side & Overhead of UPS: Omm (no clearance required)
Rear of UPS: 150mm clearance required
FRONT VIEW
7. For external MBS wiring, please refer to the appropriate wiring diagram that is supplied with MBS
8. All wiring and cabling is to be in accordance with National and Local Electrical Standards
9. Please also refer to appropriate battery cabinet site plan drawing
10. Optional External Batteries are available for extended runtimes
(Internal batteries will not be installed if External Battery Cabinets are used)
AICA
_ 730 _
À
of | |
A
Ÿ | В
150mm Rear
TOP VIEW Clearance
4 |
UPS p
<
Е| || 1BATT
2ВАТТ
HO
— WHEELS
FRONT VIEW SIDE VIEW
(WITH FRONT PANEL)
BOTTOM VIEW
JACKING SCREW
RECTIFIER SUPPLY
CIRCUIT BREAKER
BATTERY CIRCUIT
BREAKER
BATTERY TERMINALS
OUTPUT TERMINALS ~|
BYPASS SUPPLY
INTEGRAL MBS
BATTERY CABINET
(Optional)
BATTERY CABINET
(Optional)
HEIGHT OF UPS
(No internal batteries)
— —
A ЫЙ]
7
===
7
REAR VIEW
UPS Part Number
DimA (mm)
9155-XX-iN0-1B-MBS, 9155-8-iN(L)14-MBS
9155-10-iN(L)10-MBS, 9155-12-iN(L)8-MBS
9155-15-iN(L)5-MBS
817
Product Specifications
9155-XX-iN0-2B-MBS, 9155-8-iN(L)33-MBS
9155-10-iN(L)25-MBS, 9155-12-iN(L)20-MBS
9155-15-iN(L)15-MBS
1214
*Drawings and UPS Specifications are subject to change.
Rated AC | Rated AC Rectifier AC Input Inverter AC Max. Heat Dimensions Approx. Floor | Airflow Maximum Cable Size
UPS Rating Input Output Current (3-Phase) Output Current [Dissipation at WxDxH Weight Loadi Req't
Voltage | Voltage 100% Load | (see above for |(No Batts) | ~229'"9 | Reqs
(3-ph) (1-ph) | Continuous | Maximum Continuous details) Input | Bypass | Output | Earth
kVA | kW VAC VAC AMP AMP AMP Watts mm kg kg/m2 | litres/sec | sq. mm | sq.mm | sq.mm | sq.mm
8 7.2 279 - 478 240 11.6 26 34.8 768 305 x 702 x DimA 60 280 300
10 9 279 - 478 240 14.5 26 43.5 933 305 x 702 x DimA 60 280 300
3x16 35 35 35
12 10.8 | 279-478 240 17.4 29 52.2 1085 305 x 702 x DimA 60 280 390
15 13.5 | 279-478 240 21.8 29 65.2 1330 305 x 702 x DimA 60 280 390
E TN
DRAWN | SCALE
GA NTS
31.7.08
FILENAME:
A4SP0004Rev0.dwg
A4
TITLE
SITE PLANNIN
G GUIDE
9155-N-MBS 8-15kVA UP
AS-1100
THIRD ANGLE PROJECTION
UNLESS OTHERWISE SPECIFED ALL
DRAWING NUMBER
A4SPG0004
0
THIS DOCUMENT IS THE COPYRIGHT OF EATON INDUSTRIES PTY LTD AND IS NOT TO BE COPIED OR DISCLOSED TO OTHERS, WHOLLY OR PARTLY, WTHOUT WRITTEN CONSENT OF SAID COMPANY.

advertisement

Related manuals

advertisement