Dacor MCS/D Troubleshooting guide


Add to my manuals
37 Pages

advertisement

Dacor MCS/D Troubleshooting guide | Manualzz

Technical Diagnostic

Quick Reference Guide

Technical Assistance Line

800-353-2267

Dacor Contact Information:

Dacor Customer Service:

800-793-0093 X 2813 [email protected]

Dacor Distinctive Service:

800-793-0093 X 2822 [email protected]

Dacor Technical Assistance:

800-353-2267 X 2 [email protected]

Dacor Warranty Administration Department:

800-793-0093 X 4806 [email protected]

Install Spec’s, Use & Care, Planning Guide: www.dacor.com

Parts and Service Information: www.dacorservice.com/PartsCatalog

V11

Technical Diagnostic Quick Reference Index

Dacor Contact information - Page: 2

Index - Page: 3 & 4

Serial Number Format – Page: 5

Oven Temperature Calibration Instructions - Pages: 6 & 7

All Models where Available

Classic Wall Oven & Range Quick ERC Test - Page: 8

Wall Oven Models: CPS/CPD, CPTS/CPTD, ECPS/ECPD, ECS/ECD, PCS/PCD, MCS/MCD Single & Double Ovens,

27, 30 & 36 inches wide.

Range Models: ERSD30/36/48, PGR30, RSE30, RSG30, RSD30, ERD30/36/48/60, ERDE36/48 MRE30, MRES30,

EGR30, ERG30/36

Classic Wall Oven & Range Fault Codes - Page: 9

Wall Oven Models: CPS/CPD, CPTS/CPTD, ECPS/ECPD, ECS/ECD, PCS/PCD, MCS/MCD Single & Double Ovens,

27, 30 & 36 inches wide.

Range Models: ERSD30/36/48, PGR30, RSE30, RSG30, RSD30, ERD30/36/48/60, ERDE36/48 MRE30, MRES30,

EGR30, ERG30/36

Discovery Wall Oven Diagnostic Mode - Page: 10

Wall Oven Models: EO130, EO230, EO127, EO227, PO130, PO230, PO127, PO227, MOV130, MOV230, MOV127,

MOV227, MOH130, MOH230, MOH127, MOH227

Discovery Wall Oven Fault Codes - Page: 11

Wall Oven Models: EO130, EO230, EO127, EO227, PO130, PO230, PO127, PO227, MOV130, MOV230, MOV127,

MOV227, MOH130, MOH230, MOH127, MOH227

Discovery Range Quick Set Guide – Page: 12

Range Models: ER30D, ER30DSR, ER36D, ER48D

Discovery Range Fault Codes – Page: 13

Range Models: ER30D, ER30DSR, ER36D, ER48D

Discovery Range Quick ERC Test – Page: 14 & 15

Range Models: ER30D, ER30DSR, ER36D, ER48D

Renaissance Oven Diagnostic Mode - Page: 16

Wall Oven Models: EORS130, EORS230, EORD230, EORS127, EORS227, EORD227, MORS130, MORS230,

MORD230, MORS127, MORS227, MORD227, RO130, ROV130, RO230, ROV230

Range Models: RR30NS, RR30NIS, RR30NFS & RR30NIFS

Renaissance Oven Fault Codes – Page: 17

Wall Oven Models: EORS130, EORS230, EORD230, EORS127, EORS227, EORD227, MORS130, MORS230,

MORD230, MORS127, MORS227, MORD227, RO130, ROV130, RO230, ROV230

Range Models: RR30NS, RR30NIS, RR30NFS & RR30NIFS

Renaissance Induction Range (Induction Generator) Technical Features – Page: 18

Range Models: RR30NS, RR30NIS, RR30NFS & RR30NIFS

Renaissance Induction Range (Induction Generator) Error Codes – Page: 19

Range Models: RR30NS, RR30NIS, RR30NFS & RR30NIFS

PG: 3

PG: 4

Technical Diagnostic Quick Reference Index Continued…

Distinctive Wall Oven & Range Diagnostic Mode - Page: 16

Wall Oven Models: DO130, DO230

Range Models: DR30D, DR30DI, DR30EF, DR30EIF, DR30E & DR30EI

Distinctive Wall Oven & Range Fault Codes – Page: 17

Wall Oven Models: DO130, DO230

Range Models: DR30D, DR30DI, DR30EF, DR30EIF, DR30E & DR30EI

Classic Dishwasher Factory Test Mode – Page: 20

Dishwasher Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24(all colors), MDV24S & MDH24S,

ID30, ED30SCH, ED30SCP, ED30SBK, ED30SBR

Classic Dishwasher Factory Fault Codes – Page: 21

Dishwasher Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24(all colors), MDV24S & MDH24S,

ID30, ED30SCH, ED30SCP, ED30SBK, ED30SBR, MDW24S & EDW24S

Second Generation Millennia Dishwasher Fault Codes – Page: 21 (bottom of page)

Dishwasher Models: MDW24S & EDW24S

Third Generation Dishwasher Diagnostic Mode – Page: 22

Dishwasher Models: DDWF24S, EDWH24S, IDWH24

Third Generation Dishwasher Control Programming and Fault Codes – Page: 23

Dishwasher Models: DDWF24S, EDWH24S, IDWH24

36” Freestanding Refrigerator Programming and Diagnostics – Page: 24 & 25

Models: EF36BNDFSS, IF36BNDFSF, EF36LNDFSF, EF36RNDFSS, IF36INDFSF, EF36BNFSS, EF36LNFSS,

EF36RNFSS, EF36BNNFSS and PF36BNDF(all colors)

36” Freestanding Refrigerator with Water/Ice Disp Programming and Diagnostics – Page 26 & 27

Model: EF36IWFSS

First Generation - Classic 42” and 48” Built-in Refrigerator Diagnostics – Page: 28 thru 31

Models: EF42BDCBSS, EF42BNDBSS, IF42BNDBOL, IF42BDCBOL, EF48BDCBSS, EF48BNDBSS, IF48BNDBOL,

IF48BDCBOL

Second Generation 36”, 42” and 48” Built-in Refrigerator Diagnostics Page: 32 & 33

Models: EF36LNBSS, EF36RNBSS, IF36LNBOL, IF36RNBOL, EF42NBSS. EF42DBSS, IF42NBOL, IF42DBOL,

EF48NBSS, EF48DBSS, IF48NBOL, IF48DBOL

WineStation – Page: 34 & 35

Models: DYWS4

Coffee System Programming – Page 36 & 37

Models: CM24P, CM24T, CM24P-1, CM24T-1

Dacor Serial Number Format:

**Prior to the 38th week of 2002 the serial number format was: FC2371234

In 2002 Dacor changed the serial number format slightly to accommodate additional product line growth by adding two (2) characters each for product code and revision and two (2) digits for the year of manufacture.

**After the 38th week of 2002 and current the serial number format is: F-C-02381234

A dash was added to separate the two codes - so that a serial number ABC representing product type AB at revision

C could not be confused as a product type A at revision BC. There is also a dash added between the revision code and year of manufacture. The year code was increased so a unit manufactured in 1992 would not be confused for a unit manufactured in 2002.

Old Format: New/Current Format:

First Letter = Product Code:

A = Accessories

B = Blowers

C = BBQ Carts

D = Dishwashers

E = Electric Modules

F = Ranges

G = Coffee System

H = Hoods

J = Electric Ranges

K = Gas Ranges

L = Integrated Hood Liners

M = Metal Cooktops/Gas & Dual Fuel (i.e. SGM and PGM)

P = Wine Coolers

R = Raised Vents

S = Epicure Cooktops

T = Electric Cooktops – Ceran

V = Wall Ovens

W = Warming Ovens/Drawers

Second Letter = Revision Level

New products always start out at revision “A”. When ever a change is made to a product in Form, Fit or Function the

Revision Level will change. A to B to C etc… (letters I and O will not be used).

First number(s) = Year Manufactured

Old Serial Number Format Example: VB7121234 = Unit was manufactured in 1997.

New/Current Serial Number Format Example: V-B-07121234 = Unit was manufactured in 2007.

Second Set of Numbers = Week Manufactured

Old Serial Number Format Example: VB7121234 = Unit was manufactured in the 12 week of 1997.

V-B-07121234 = Unit was manufactured in the 12 th week of 2007. New/Current Serial Number Format Example:

Last Four Numbers = Unit Number

Old Serial Number Format Example: the 12 th week of 1997.

VB7121234 = This Product is Unit Number: 1234 and was manufactured in

New/Current Serial Number Format Example: manufactured in the 12 th week of 2007.

V-B-07121234 = This Product is Unit Number: 1234 and was

Dacor Technical Assistance: 800-353-2267 PG: 5

Oven Temperature Calibration Instructions:

Classic Wall Oven & Range Temperature Calibration Procedure

Wall Oven Models: CPS/CPD, CPTS/CPTD, ECPS/ECPD, ECS/ECD, PCS/PCD, MCS/MCD Single & Double

Ovens, 27, 30 & 36 inches wide.

Range Models: ERSD30/36/48, PGR30, RSE30, RSG30, RSD30, ERD30/36/48/60, ERDE36/48, MRE30,

MRES30, EGR30 & ERG30/36

Classic Products – All models WITH Bake Keypad:

 Select a Bake Cycle, Increase Temperature to 500˚F.

 Quickly press and Hold Bake Keypad until display changes.

 Use Temp Up/Down keypad to select amount of Calibration up to +/-35˚F.

 Press Cancel to lock in new setting. Factory setting is “00”.

Classic Range Model: ERD48 WITHOUT Bake Keypad:

 Turn Power Off to unit.

 Press and hold Cancel Key for the small oven.

 Turn power back on while holding Cancel Key. Two Orange “00” will display.

 Quickly press Cancel Key again. “00” will appear on the large oven display.

 Use Temp Up/Down keypad on large oven to select amount of Calibration up to +/-35˚F.

 Press Cancel

to lock in new setting. Factory setting is “00”.

Classic Range Model: ERD36 WITHOUT Bake Keypad:

 Turn Power Off to unit.

 Press and hold Cancel Key.

 Turn power back on while holding Cancel Key. Two Orange “00” will display.

 Use Temp Up/Down keypad on large oven to select amount of Calibration up to +/-35˚F.

Press Cancel

to lock in new setting. Factory setting is “00”.

Discovery Wall Oven Temperature Calibration Procedure

Wall Oven Models: EO130, EO230, EO127, EO227, PO130, PO230, PO127, PO227, MOV130, MOV230,

MOV127, MOV227, MOH130, MOH230, MOH127 & MOH227

 Press and HOLD “#” keypad, Press and HOLD Cancel/Secure keypad.

 Hold both buttons for 5 seconds.

 Once the display changes, let go of the Cancel/Secure keypad first then the “#” Keypad. Enter your

Dacor Servicer Identification Number (or: S1236) and press Enter.

 For Double ovens (single oven skip this step), select the oven that is to be Calibrated (Upper or Lower).

 Press the Service Temp keypad then the OK keypad to acknowledge the Calibration Warning.

 Using the Number Keypad, select the corresponding number next to the Cycle you wish to Calibrate.

 Once the desired Cycle is Highlighted, Press the +5˚F or -5˚F to select the amount of Calibration.

 Once the desired Calibration is displayed, press the OK keypad to lock in new setting.

 Press the Cancel/Secure keypad to EXIT the Temperature Calibration Mode.

PG: 6

Dacor Technical Assistance: 800-353-2267

Oven Temperature Calibration Instructions Continued:

Discovery Dual Fuel Range Temperature Calibration Procedure

Range Models: ER30D, ER30DSR, ER36D & ER48D

 Press and HOLD Bake Keypad for 10 seconds or until the display changes.

 Using the Number Keypad, enter the new Calibration Offset.

 Use the Self Clean Keypad to select “+” or “-” up to +/-35˚F.

 Press Cancel to lock in new setting. Factory setting is “00”.

Renaissance & Distinctive Wall Oven & Electric & Duel Fuel Range Temp Calibration Procedure

Renaissance Wall Oven Models: EORS130, EORS230, EORD230, EORS127, EORS227, EORD227,

MORS130, MORS230, MORD230, MORS127, MORS227, MORD227, RO130, ROV130, RO230 & ROV230

Renaissance Range Models: RR30N, RR30NI, RR30NF & RR30NIF

Distinctive Wall Oven Models: DO130 & DO230

Distinctive Range Models: DR30D, DR30DI, DR30EF, DR30EIF, DR30E & DR30EI

 Press and HOLD the “0” and “#” keypads at the same time. After about 3 seconds, the display will read: PASS.

 Using the Number Keypad, enter pass code: 6-4-2-8 then press the Start Keypad. The display will change and read: SLCE “00”.

 Quickly select the cooking mode that needs to be Calibrated. Using the Number Keypad enter the new

Calibration Offset.

 Use the “#” Keypad to select “+” or “-” up to +/-35˚F.

 Press START to lock in new setting. Factory setting is “00”. Press CANCEL to complete procedure.

Renaissance & Distinctive All-Gas Range Temperature Calibration Procedure

Renaissance All-Gas Range Models: ER30G, ER30GI, ER36G, ER36GI

Distinctive All-Gas Range Models: DR30GF, DR30GIF, DR30G & DR30GI

 Disconnect Range from Power Supply.

 Pull unit out from wall and remove rear panel of range to access the Relay Board.

 The relay board will have dip-switches mounted near the center of the board.

 Use the chart below to enter Calibration Offset.

 Reassemble Range and restore power.

Dacor Technical Assistance: 800-353-2267

PG: 7

Dacor Classic Wall Oven and Range ERC Quick Test

Wall Oven Models: CPS/CPD, CPTS/CPTD, ECS/ECD, PCS/PCD, MCS/MCD Single & Double Ovens, 27” & 30”

Range Models: PGR30, RSE30, RSG30, RSD30, ERD30-60, ERDE36-48 MRE, MRES30, EGR30, ERG30-36

To access the ERC Quick Test Program:

Turn circuit breaker off or disconnect power to unit, count to five and then turn power back on. Make sure time of day is blinking. Push and hold COOK TIME. Within 5-10 seconds the EEPROM number will display. The display will show the 4character identification code of the ERC. Example (1180)

You have 30 seconds between each test mode.

Note: If unit shows time of day start procedure over again.

Test: Membrane Key: Component Activated: Description:

1 Convection Bake Bake Element &

Convection Fan

PRESS and HOLD to activate Bake Element and Convection

Fan Motor

2 Bake

3 Pure Convection

4 Broil

Bake Element

Convection Element &

Convection Fan

Press and Hold to activate the Bake Element Only

PRESS and HOLD to activate Convection Element and

Convection Fan Motor

Press and Hold to activate the Broil Element or Ignitor Only

5 Convection Broil

Broil Element or Broil

Ignitor (on gas units)

Broil Element &

Convection Fan

PRESS and HOLD to activate Broil Element and Convection

Fan Motor (select Models only)

6 Timer 2

7 Stop Time

8 Clock

9 Cook Time

Audible Tone

Cooling Fan

Clock LED’s

Door Latch

PRESS and HOLD to activate the Audible Tone

PRESS and HOLD to activate the Cooling Fan Only.

PUSH and HOLD to momentarily view all clock LED’s.

With Door Oven, PRESS and HOLD for 10 seconds to activate

Door Latch. Door Latch will complete one cycle. The Quick

Test will end and ERC will display the time of day.

Note: Holding the Membrane Key down for longer that 30 Seconds at a time could cause an F-0 (Stuck Key

Pad) Error Code.

Celsius to Fahrenheit Conversion:

There have been some occurrences where the clock has changed from Fahrenheit to Celsius. If this situation occurs please perform the following to reset the ERC for proper operation:

Press CONVECTION BAKE key. This will activate the convection bake cycle on the oven display. Adjust the temp to above

500˚F. Press and hold the CONVECTION BAKE key for about five seconds until the "C" appears and then hit +/- (slew) key to toggle to "F". This will work in reverse if the temp for "C" is above 260˚C

Military Time Format – Clock Runs Fast:

There have been some occurrences where the Time readout has been in a 24 hour Military Time Format. In addition, there are also instances where the clock is set for a 50 HZ operational mode causing the readout to gain time. If either of these situations occurs please perform the following to reset the ERC for proper operation:

Turn power off at breaker, count to five and then turn power back on. Make sure time of day is blinking. Push and hold

CLOCK Key until a single digit number appears. You may then release the CLOCK Key. Using the "Time-Temp" arrow keys, adjust the number in the display to read the digit "8", and release button. After approximately 15 seconds, the time of day will appear. Set the clock to the correct time of day. The oven will now function properly.

Adjusting the Cooling Fan Cutout Temperature (select Models):

Dacor wall ovens and ranges come preset with the cooling fan cut out preset at 300˚F. (Please note that 300˚F and the indication 000 are the same.) In certain applications, (high or low ambient temps or high altitude) you may want to modify the default setting of the cooling fan cutout temperature. It can be adjusted from 400˚F, 300˚F or 200˚F. To modify the setting, please perform the following sequence waiting no more than three seconds between keystrokes.

• Press broil keypad

• Press the plus temperature keypad

• Press and hold the broil keypad until the display indicates three red numbers on the right side of the display

• Once the cutout temperature is displayed use the plus or minus temperature keypads to raise or lower the setting

• Press cancel secure

PG: 8

Dacor Classic Wall Oven and Range Fault Codes

Wall Oven Models: CPS/CPD, CPTS/CPTD, ECS/ECD, PCS/PCD, MCS/MCD Single & Double Ovens, 27” & 30”

Range Models: PGR30, RSE30, RSG30, RSD30, ERD30-60, ERDE36-48 MRE, MRES30, EGR30, ERG30-36

-F0- Shorted Or Jammed Input Device

This failure will appear if a shorted or jammed input device is defective. Possible causes include shorted wires or a defective membrane switch.

-F1- Alarm “System Watchdog Circuit”

ERC Self-Diagnostic circuitry has detected a failure in the bake/broil system. Any portion of the ERC, relay board, touch pad, heating elements and related wiring may be at fault.

How to diagnose/repair potential cause:

Step 1: Disconnect membrane from ERC. If an F-1 alarm is not activated within 30 seconds, check membrane function test points with an OHM meter. (refer to page 20 of the Diagnostic Test Manual) If the membrane test switch fails, replace membrane. If membrane test is good, continue to step 2.

Step 2: At ERC check for 24 VDC between J2 pins 1 and 3 for upper/single ovens or J5 pins 7 and 10 for lower ovens

(when lower oven is not in a cooking/clean mode) **Note: F-1 must be showing in the ERC/Clock Display. I you read 24

VDC at those test points, replace ERC

-F2- Alarm Heating Mode High Temperature

Is activated when the ERC senses a runaway heat condition or when the temperature exceeds “runaway limits”. The ERC will beep until the cancel or another function is selected. If the alarm repeats the F2 alarm check the oven sensor and wiring after first checking for a stuck relay. If alarm goes away verify the oven will complete a clean cycle without any type of failure.

-F3- Alarm Shorted Oven Sensor

Occurs when the ERC senses a short circuit in the oven temperature sensor for 16 temperature conversions in a row. F-3 will appear in the digits and a beeping will be heard. If the alarm does not go away after pressing the cancel key check the sensor and wiring. **Important Note: This test will only be performed while a cooking operation is being attempted.

The F3 alarm will not be displayed in the time of day mode.

-F4- Alarm Open Oven Sensor

“F4” will be displayed along with a beeping if the ERC determines an open oven temperature sensor circuit for 16 consecutive oven temperature conversions. **Important note: This test will only be performed while a cooking operation is being attempted. The F4 message will not be displayed in the time of day mode. **Important note: If the oven sensor is open the bake modes cannot be activated. The controls will be non-responsive. Look for this failure, as at first appearance you may suspect the ERC or selector instead of an open sensor. A strange number may also appear in this failure mode.

-F5- ERC self-diagnostic failure

Replace ERC.

-F6- Alarm EEPROM Checksum Error

The brain of this oven (so to speak) operates a series of software commands. These commands control the various features and functions of the oven. A numerical value has been assigned to each function or operation. The numerical values can be added up - this is the check sum operation. Every time the system is powered up and after each clean cycle the system performs a check sum and compares the value to the value programmed into the software. (stored in memory.) An EEPROM check sum error or F-6 alarm occurs when the values differ. Only the time of day and timer operation will operate. If you receive a F-6 alarm replace the ERC.

-F7- Alarm Door Lock Enabled Above Temperature

“F7” will appear in the digits and a beeping will be heard if a failure in the clean lock/ phase circuitry is detected for 16 seconds in a row. Check the door lock switches and door adjustments.

-F8- Alarm Door Locking Switch

Occurs when operating the door lock motor if the motor runs for two minutes without seeing the phase switch change positions. This failure will normally occur only when a clean mode is started. If it occurs check the door switches and wiring.

Dacor Tec-Line 800-353-2267 PG: 9

Dacor Discovery Oven Diagnostic Mode:

Models: EO, PO, MOV, MOH, SINGLES AND DOUBLES, 27” AND 30”

To Enter Diagnostic Mode: With the main power supply to the oven turned on, press and hold the CANCEL/SECURE and # keys at the same time. When the diagnostic password screen appears, release the

CANCEL/SECURE key first then the # key.

Page 8-1

Enter your Dacor Authorized Servicer Number:

Press the 7 key on the keypad repeatedly until the letter S appears just below the words SERVICE ID NUMBER. Wait 3 seconds. Enter your Dacor Servicer

Number. Press ENTER. Page 8-1

FACTORY and SERVICE DIAGNOSTIC HOME SCREEN:

This screen allows you to access 5 options: VERSION, MANUAL DIAGNOSTIC,

SERVICE TEMP, FACTORY TEMP, and ERROR CODES.

When done with the diagnostic screen, press CANCEL/SECURE, to return to home screen. Page 8-1

VERSION: Use this option to access information about the software versions programmed into the oven’s printed circuit boards. Important: The Versions and checksums for the upper and lower relay boards on a double oven must match for the ovens to work properly. Page: 8-2

MANUAL DIAGNOSTIC: Use this option to diagnose problems with individual components and cooking modes. This diagnostic screen offers (4) options for exercising the oven components in a matter that will allow diagnosis of various types of failures: Outputs, Inputs, Modes 1 and 2. Page 8-4

MANUAL DIAGNOSTIC – OUTPUTS: This diagnostic mode allows the Service

Tech to turn each output component in the oven on by itself while leaving all other components off. To turn on a particular component, press the appropriate number on the keypad. The display will indicate the component that has been turned on.

Page: 8-4

MANUAL DIAGNOSTIC – INPUTS: This diagnostic screen allows the Service

Tech to monitor all of the input components while stimulus is supplied. Page 8-4

MANUAL DIAGNOSTIC – MODE 1 AND 2: This diagnostic screen allows the

Service Tech to set the oven to a cooking mode without having to exit the diagnostics to the home screen. Page 8-6

SERVICE TEMP: The service temp screen allows the Service Tech to modify the calibration of the various oven cooking modes. The settings on the SERVICE

TEMP screen indicate the amount by which the factory calibration setting settings are raised or lowered. Return the oven to factory settings by changing all the

SERVICE TEMP settings back to zero. Page: 8-7

FACTORY TEMP: These are the base calibration settings made at the factory.

Dacor does not recommend modifying these settings. If the FACTORY TEMP settings must be changed, they are changed in the same manner as the

SERVICE TEMP settings. Page: 8-7

ERROR CODES: This screen will display the twenty (20) most recent error codes stored in the oven controller. The most recent error code will appear in the number one (1) position on the display. Remember to press the CLEAR ALL key before exiting the ERROR CODES SCREEN. Page: 8-8

PG: 10 Dacor Tec-Line: 800-353-2267

Dacor Discovery Oven Fault Codes:

Models: EO, PO, MOV, MOH, SINGLES AND DOUBLES, 27” AND 30”

Error Code: Description of Failure: Page: Error Code: Description of Failure: Page:

U20 OVER TEMP (UPPER/SINGLE) Cook temp over 610F for 2 min

L20 OVER TEMP (LOWER) Cook temp over 610F for 2 min

U21 OVER TEMP (UPPER/SINGLE) Clean temp over 890F

9-34 U43 RELAY BOARD (UPPER/SINGLE) Bad connection on S19 relay or bad Relay Board

9-34 L43 RELAY BOARD (LOWER) Bad connection on S19 relay or bad Relay Board

9-35 U50 LATCH/DOOR (UPPER/SINGLE) No closure of lock switch is detected

L21 OVER TEMP (LOWER) Clean temp over 890F 9-35 L50 LATCH/DOOR (LOWER) No closure of lock switch is detected

U22 OVER TEMP (UPPER/SINGLE) One of the sensors are out of calibration or bad 9-35 U51 LATCH/DOOR (UPPER/SINGLE) No closure of phase switch is detected

L22 OVER TEMP (LOWER) One of the sensors are out of calibration or bad 9-35 L51 LATCH/DOOR (LOWER) No closure of phase switch is detected

U23 OVER TEMP (UPPER/SINGLE) Ambient Temp around relay board is too high 9-36 U52 LATCH/DOOR (UPPER/SINGLE) Bad Lock Switches or possible bad Relay Board

L23 OVER TEMP (LOWER) Ambient Temp around relay board is too high 9-36 L52 LATCH/DOOR (LOWER) Bad Lock Switches or possible bad Relay Board

9-42

9-42

U24 OVER TEMP (UPPER/SINGLE) Ambient Temp probe on relay board is open 9.36 U53 LATCH/DOOR (UPPER/SINGLE) The Door Switch is open when the Lock Switch is closed 9-43

L24 OVER TEMP (LOWER) Ambient Temp probe on relay board is open 9-36 L53 LATCH/DOOR (LOWER) The Door Switch is open when the Lock Switch is closed 9-43

U25 OVER TEMP (UPPER/SINGLE) Ambient Temp probe on relay board is shorted 9-37 U54 LATCH/DOOR (UPPER/SINGLE) Bad Relay Board

L25 OVER TEMP (LOWER) Ambient Temp probe on relay board is shorted 9-37 L54 LATCH/DOOR (LOWER) Bad Relay Board

U30 TEMP SENSOR (UPPER/SINGLE) Open RTD 1/Check Wiring at Connection Pts. 9-37 U55 LATCH/DOOR (UPPER/SINGLE) Bad Latch Motor or Bad Relay Board

L30 TEMP SENSOR (LOWER) Open RTD 1/Check Wiring at Connection Pts. 9-37 L55 LATCH/DOOR (LOWER) Bad Latch Motor or Bad Relay Board

9-43

9-43

9-43

9-43

9-40

9-40

9-41

9-41

9-42

9-42

U31 TEMP SENSOR (UPPER/SINGLE) Shorted RTD 1/Check Wiring at Connection Pts. 9-37 U60 COOLING FAN (UPPER/SINGLE) Check Cooling Fan operation/Blocked Airflow / Low Speed 9-44

L31 TEMP SENSOR (LOWER) Shorted RTD 1/Check Wiring at Connection Pts. 9-37 L60 COOLING FAN (LOWER) Check Cooling Fan operation/Blocked Airflow / Low Speed 9-44

U32 TEMP SENSOR (UPPER/SINGLE) Open RTD 2/Check Wiring at Connection Pts. 9-37 U61 COOLING FAN (UPPER/SINGLE) Check Cooling Fan operation/Blocked Airflow / High Speed 9-45

L32 TEMP SENSOR (LOWER) Open RTD 2/Check Wiring at Connection Pts. 9-37 L61 COOLING FAN (LOWER) Check Cooling Fan operation/Blocked Airflow / High Speed 9-45

U33 TEMP SENSOR (UPPER/SINGLE) Shorted RTD 2/Check Wiring at Connection Pts. 9-38 U70 COMM ERROR (UPPER/SINGLE) Loss of Upper Power Board Communication 9-45

L33 TEMP SENSOR (LOWER) Shorted RTD 2/Check Wiring at Connection Pts. 9-38 L70 COMM ERROR

U34 TEMP SENSOR (UPPER/SINGLE) Open RTD 3/Check Wiring at Connection Pts. 9-38 C72 COMM ERROR

L34 TEMP SENSOR (LOWER) Open RTD 3/Check Wiring at Connection Pts. 9-38 C73 COMM ERROR

U35 TEMP SENSOR (UPPER/SINGLE) Shorted RTD 3/Check Wiring at Connection Pts. 9-38 C74 COMM ERROR

Loss of Lower Power Board Communication

No communication between logic and relay boards

Verify software compatability and relay board ID settings

Failure on Logic Board

9-45

9-46

9-47

9-47

L35 TEMP SENSOR (LOWER)

N/A - SOFTWARE ONLY

Shorted RTD 3/Check Wiring at Connection Pts. 9-38 C75 COMM ERROR

All Probes Fail 9-39 C76 CONFIG

U40 RELAY BOARD (UPPER/SINGLE) Bad Relay Board/Verify Harness Connections 9-39 C77 CONFIG

L40 RELAY BOARD (LOWER) Bad Relay Board/Verify Harness Connections 9-39 C78 DISPLAY PANEL LIGHTS

Failed Controller

Replace glass/touchpad assembly

Replace glass/touchpad assembly

Display voltage has dropped below 15V

U41 RELAY BOARD (UPPER/SINGLE) Bad Relay Board/Verify Harness Connections 9-39 U80 MEAT PROBE (UPPER/SINGLE) Check for shorted/open wires/probe

L41 RELAY BOARD (LOWER) Bad Relay Board/Verify Harness Connections 9-39 L80 MEAT PROBE (LOWER) Check for shorted/open wires/probe

U42 RELAY BOARD (UPPER/SINGLE) Failure on Relay Board

L42 RELAY BOARD (LOWER) Failure on Relay Board

9-40 C90 POWER LOSS

9-40

Clear Failure Code and retest cooking modes

9-47

9-48

9-48

9-48

Dacor Tec-Line: 800-353-2267

PG: 11

Dacor Discovery Range Quick Set Guide

Range Models: ER30D, ER30DSR, ER36D & ER48D

Control Panel Position:

The Control panel can be swiveled to a 50° angle for easier viewing and use.

To pivot control panel:

1. Push in on the bottom of the control panel where it says “PRESS HERE”. The control panel will pivot up.

2. Pull the bottom of the control panel housing (under

“PRESS HERE”) until it locks in place.

To put the control panel back in vertical position:

1. Pull the bottom of the control panel housing (under

“PRESS HERE”) to unlock it.

2. Push in where it says “PRESS HERE” until it locks into the vertical position.

Turning Off the Oven:

To turn the oven off, press the CANCEL/SECURE key.

NOTE: After you turn off the oven, the cooling fans may continue

Changing the Temperature

(after you press START)

1. Press the key for the current cooking mode. The current cooking mode appears on the display (for example BAKE).

2. Enter the temperature on the keypad (for example 3-7-5) and press START.

Changing the Oven Cooking Mode

(after you press START)

To change to a different cooking mode while the oven is on, for example to change from convection bake to bake:

1. Press the key for the new cooking mode, for example

BAKE.

2. Press START.

PG: 12

Setting the Clock:

1. Press the CLOCK key. “TIME” will flash on the display.

2. Enter the current time and press START. For example:

For 12:08 Press 1-2-0-8 on the keypad, then press start.

Important: After pressing the clock key, you must enter the time and press START soon afterward. If you wait longer than six seconds between pressing keys, the display will go back to the original setting. The clock cannot be set during delay timed cooking or if one or both timers are in use. After a power failure, the time on the display will flash, indicating that the time may not be correct.

Starting the Oven:

1. Adjust the racks to the appropriate level.

2. Determine the best cooking mode for the type of food to be cooked.

Select from the following:

• CONVECTION BAKE - A combination of the convection fan and

a bottom heat source.

• CONVECTION BROIL - A combination of the convection fan

and a top heat source.

• PURE CONVECTION™ - Uses convection cooking only for

even heat.

• BAKE - Cooks with a bottom heat source only.

• BROIL - Cooks using a top heat source alone.

• CONVECTION ROAST - Combines top and bottom heat

sources with the convection fan.

IMPORTANT: The broil modes will not work when the meat probe is connected.

3. Press the key for the desired cooking mode. The preset

(jump-in) temperature will appear on the display.

4. Press START, to cook at the preset temperature. Or you

may enter a different cooking temperature (for example 3-5-0)

on the number keypad, then press START.

You can enter any temperature between 100°F and 555°F. The suggested broil temperature is 555°F. On model ER48D the same

START key is used to start both ovens.

If you are using one of the bake or roast modes, “PRE-” for preheating, along with the current oven temperature will appear on the display until the oven reaches the set temperature. Once the set temperature is reached, the oven will beep and “PRE-” will disappear from the display. Carefully place your food in the oven.

Excessive browning will occur if you put the food in too soon.

Lock-Out Feature

If you want to disable the keys on the control panel when the oven is not in use:

• Push and hold the CANCEL/SECURE key for about four

seconds. The control panel keys will stop working and

OFF“ will appear on the display. Only the CANCEL/SECURE and the oven light keys remain functional.

• To reactivate the control panel, press and hold the

CANCEL/SECURE key for four seconds. On the ER48Dmodel, press either CANCEL/SECURE key to disable the entire control panel.

F3

F9

Dacor Discovery Range Fault Code Troubleshooting Guide

Models: ER30D, ER30DSR, ER36D and ER48D

General Error Codes

The following codes give a general indication of the location of problems detected by the control panel controller board. They are usually followed by another, more specific error code (see below).

ERROR CODE

F1

F2

GENERAL LOCATION

INTERNAL

COMMUNICATION BETWEEN CONTROL PANEL AND RELAY

BOARD

EXTERNAL

DOOR LOCK

Specific Error Codes

ERROR CODE DESCRIPTION

F10

F11

F13

F14

F15

F20

F30

Clean/Cook

Runaway

Shorted Key

POSSIBLE SOLUTION

Tighten sensor connections for replace temperature sensor.

Replace power board.

Replace keypad membrane.

Eprom Failure Control panel failure.

Watchdog

Circuit

Defective power board.

Fuse Error

Communication

Failure

Defective power board.

Data cable between relay board and control panel loose or defective.

Replace power board.

Replace power board.

Replace power board.

Tighten connections, replace if necessary.

Defective control panel circuit board. Replace control panel circuit board.

RTD Short

POSSIBLE CAUSE

Intermittent temperature sensor or loose sensor wiring.

Shorted element relay.

Shorted key (button) on keypad membrane.

F31

F32

F90

F95

RTD Open

Key Loop

Detect Failure

Door Unlock

Timeout

Door Lock

Protect Circuit

Shorted temperature sensor. Replace sensor.

Shorted temperature sensor wiring. Repair sensor wiring.

Open temperature sensor.

Open temperature sensor wiring.

Replace sensor.

Replace sensor wiring.

Data cable between relay board and control panel loose or defective.

Defective membrane.

Cables to door latch loose or defective.

Defective door latch assembly.

Defective power board.

Tighten connections, replace if necessary.

Replace membrane.

Tighten connections or repair cable.

Replace door latch assembly.

Replace power board.

Dacor Technical Assistance: 800-353-2267

PG: 13

Dacor Discovery Duel-Fuel Range ERC Diagnostic Test

Models: ER30D, ER30DSR, ER36D, ER48D and ER60D

To access the ERC Diagnostic Test:

Turn circuit breaker off or disconnect power to unit , count to five and then turn power back on. Within the first 30 seconds after power up, press and hold the BAKE and BROIL keys for 6 to 10 seconds.

Test 1: Latch Motor right/large oven – LOCK/UNLOCK

Press the CLEAN key. Verify that the Latch Motor is moving and that the lock icon is flashing. If the oven door in not closed then block the latch so it will lock. When the latch reaches the locked position verify that the lock motor stops and the LOCK icon is on steady. Verify that the CLEAN icon turns on under the clock digits and the clock digits show “3:00” and the HR icon is lit. Press the CLEAN key again to unlock.

Test 2: EPROM Version of control board

Press the START key. Verify that the EPROM Version of the control board is shown in the temperature digits.

Test 3: Flash Version of control board

Press the PROBE key. Verify that the Flash Version of the control board is shown in the clock digits.

Test 4: Software Version of relay board

Press the CLOCK key. Verify that the Software Version of the relay board is shown in the clock digits.

Test 5: Numeric Keys

Press each one of the number keys on the keypad one at a time. Verify that with each press the same number as the key is shown in the temperature digits repeated three times.

Test 6: Oven Lights ON/OFF

Press the LIGHT key. Verify that the oven lights turn on. Press the LIGHT key again. Verify that the oven lights turn off.

Test 7: Cooling Fan and Temperature Sensor

Press the COOK TIME key. Verify that the TIMED icon is lit. Verify that the Cooling Fan turns on first by the sound and then by feel of airflow from exhaust. Verify that the temperature of the oven is displayed in the temperature digits and is about ambient temperature (65˚-100˚F).

Test 8: Latch Motor left/small oven – LOCK/UNLOCK (for 48” range otherwise skip step)

Press the left/small oven CLEAN key. Verify that the Latch Motor is moving and that the lock icon is flashing. If the oven door in not closed then block the latch so it will lock. When the latch reaches the locked position verify that the lock motor stops and the LOCK icon is on steady. Verify that the CLEAN icon turns on under the clock digits and the clock digits show

“3:00” and the HR icon is lit. Press the left/small oven CLEAN key again to unlock.

Test 9: Delay Icon right/main oven

Press the START TIME key (right/large oven side). Verify that the DELAY icon (right/main side) is lit.

Test 10: Delay Icon left/small oven (for 48” range otherwise skip step)

Press the START TIME key (left/small oven side). Verify that the DELAY icon (left/small side) is lit.

Test 11: PRE icon right/large oven

Press CONVECTION BROIL key. Verify that the PRE icon is lit.

Test 12: Oven Number Icon (for 48” range otherwise skip step)

Press left/small oven CANCEL key. Verify that all or the number “1” or “2” icon is lit. Press left/small oven CANCEL key again. Verify that the other number icon is lit.

Test 13: Bake Element right/large oven side

Press the right/large oven side BAKE key and verify that the BAKE and ON icons are lit. Verify that the Bake Element begins to heat (glow red) and that between 10 and 14 amps are being drawn.

Test 14: Broil Element right/large oven side

Press the right/large oven side BROIL key and verify that the BROIL and ON icons are lit. Verify that the Bake Element begins to heat (glow red) and that between 10 and 15 amps are being drawn.

Test 15: Convection Element right/large oven side

Press the right/large oven side CONVECTION BAKE key and verify that the CONV. BAKE and ON icons are lit. Verify that the

Convection Element begins to heat (glow red) and that between 8 and 12 amps are being drawn. Verify that the Convection

Fan turns on.

Tec-Line: 800-353-2267

PG: 14

Test 16: Convection Fan right/large oven side

Press the right/large oven side PURE CONV. Key and verify that the CONV. And ON icons are lit. Verify that the Convection

Fan turns on.

Test 17: Bake Element left/small oven side (for 48” range otherwise skip step)

Press the left/small oven side BAKE key and verify that the BAKE and ON icons are lit. Verify that the Bake Element begins to heat (glow red) and that between 10 and 14 amps are being drawn.

Test 18: Broil Element left/small oven side (for 48” range otherwise skip step)

Press the left/small oven side BROIL key and verify that the BROIL and ON icons are lit. Verify that the Bake Element begins to heat (glow red) and that between 10 and 15 amps are being drawn.

Test 19: Convection Element left/small oven side (for 48” range otherwise skip step)

Press the left/small oven side CONV. BAKE key and verify that the CONV. BAKE and ON icons are lit. Verify that the

Convection Element begins to heat (glow red) and that between 8 and 12 amps are being drawn. Verify that the Convection

Fan turns on.

Test 20: Convection Fan left/small oven side (for 48” range otherwise skip step)

Press the left/small oven side PURE CONV. Key and verify that the CONV. and ON icons are lit. Verify that the Convection

Fan turns on.

Test 21: Error Codes

Press the TIMER 1 key. Verify that the error codes show in the temperature digits. If no fault codes are present display will show “---“.

Test 22: Clear Error Codes

Press and hold the TIMER 2 key for at least 6 seconds. Verify that the temperature digits show “---“.

To EXIT ERC Diagnostic Test:

Press right/large oven CANCEL key. Verify that the display returns to the time of day mode. Verify that the time shown has progressed.

Other ERC Tests:

Lock Out Feature:

Press the CANCEL/SECURE key and hold for 5 seconds. Verify that the LOCKED icon is lit. Press other keys and verify that no actions occur. Press the CANCEL/SECURE key and hold for 5 seconds. Verify that the LOCKED icon is not lit. Press BAKE key. Verify that the bake mode display is shown. Press CANCEL/SECURE. Verify that the screen shows the time of day.

Meat Probe:

Inset Meat Probe into oven socket. Press BAKE key then START key. Press PROBE key the START key. Verify that the Meat

Probe is accepted and showing PRB icon and temperature value of 90 or greater in the temperature digits. Press CANCEL and remove Meat Probe to exit.

12/24-Hour Mode:

Press and hold the CLOCK key for 10 seconds. Verify that the clock digits show “12HR” or “24HR”. Toggle setting by pressing SELF CLEAN key until the display show desired setting. Factory setting is “12HR”. Press CANCEL key to exit.

12-Hour Cook Mode: (This option is used to limit the maximum cooking time. If it is ON the cooking is limited to 12 hours)

Press and hold the TIMER 1 key for 10 seconds. Verify that the clock digits show 12HR and the temperature digits show

“ON” or “OFF”. Press the SELF CLEAN key to toggle between ON and OFF. Factory setting is “ON”. Press CANCEL key to exit.

UPO Settings: (

User programmable offset. Temperature offset to increase / decrease the calibration. The setting will affect all modes)

Press and hold BAKE key 10 seconds. Using the numeric keypad: select your desired temperature adjustment. The controller is adjustable in single degree increments and has a maximum slew of 35˚F. Factory setting is “0”. Press the SELF-

CLEAN key to toggle between + and -. Press CANCEL key to exit.

Celsius / Fahrenheit Setting:

Press and hold the BROIL key for 10 seconds. Verify that the “C” or “F” shoes in the temperature digits. Toggle between

“C” and “F” using the SELFCLEAN key. Factory setting is “F”. Press CANCEL key to exit.

Silent Mode Setting:

Press and hold the START TIME key for 10 seconds. Verify that the click digits show “BEEP”. Verify that the temperature digits either “ON or “OFF”. Toggle between “ON” and “OFF” using the SELFCLEAN key. Press CANCEL key to exit.

Timers:

Press TIMER 1, then number 1 then START key. Verify that the timer changes from 1:00 to 0:59 and continues to count down. Press TIMER key again. Verify that the clock shown 0:00 to cancel timer. Repeat for TIMER 2.

PG: 15

Dacor Renaissance & Distinctive Oven/Range Quick ERC/Diagnostic Test

Wall Oven Models: EORS127, MORS127, EORD227, MORD227, EORS227, MORS227S, EORS130, MORS130,

EORD230, MORD230, EORS230, MORS230, RO130, ROV130, RO230, ROV230, DO130 & DO230

Range Models: RR30N, RR30NI, RR30NF, RR30NIF, DR30D, DR30DI, DR30EF, DR30EIF, DR30E & DR30EI

To enter Quick ERC/Diagnostic Test Mode:

Disconnect power to unit, wait five seconds, turn power back on. Wait for the time of day to start blinking then, within 30 seconds, press and hold the “BAKE” and “BROIL” keypads (of the upper oven if working on a double oven) simultaneously until the control shows all display prompts then release the keypads. Within 6-

12 seconds the display prompts will disappear leaving a blank screen. Follow Test procedure below. Press "CANCEL" keypad at any time to exit test mode".

To avoid damage to product, exit the test mode by pressing CANCEL or reset power supply once test is complete.

Do Not activate Door Latch in Diagnostic Mode. See Home Screen Test Mode for Door Latch test.

Single/Upper Oven Test

Test Description

Numeric Keys

Bake Element

Broil Element

Convection Bake

Convection Broil

Pure Convection

Convection Fan

Meat Probe

Operation (upper oven only)

Requirement

Press each number key. The number will be displayed on the control display.

Press the BAKE key. Verify bake element is on, measure amperage (approx 11-13)

Press the Broil key. Verify broil element is on, measure amperage (approx 12 -16)

Press the Convection Bake key. Verify Bake & Convection Elements are on, measure amperage (approx 20

-23). Convection Fan will be on.

Press the Convection Broil key. Verify Broil & Convection Elements are on, measure amperage (approx 22 -

26). Convection Fan will be on.

Press the Pure Conv. key. Verify Conv. element is on, measure amps (approx 9-11). Conv. Fan will be on.

Press the Convection Roast key. Verify Convection Fan is on, measure amps (approx 0.1 - 0.8).

Press the "Cook Time" or "Duration" key (depending on model). Control will display "Opn" (indicating that the probe circuit is open) and "Prob" (indicating that you are testing the probe circuit). Install the meat probe into the probe socket and "Opn" will change to ambient probe temperature. Warm end of probe with hand and temp read-out should increase.

Control (clock)

Temp

Press the START TIME key. Temperature of the Control (Clock) will be displayed.

Relay Board

Temp

Press the STOP TIME key. Temperature of the Relay Board will be displayed.

RTD Test

Lower Oven Test

Test Description

Bake Element

Broil Element

Press the TIMER 1 key. Interior oven temperature will be displayed.

Requirement

Press the BAKE key. Verify bake element is on, measure amperage (approx 11-13)

Press the Broil key. Verify broil element is on, measure amperage (approx 12 -16)

Convection Bake

Convection Broil

Pure Convection

Convection Fan

Press the Convection Bake key. Verify Bake & Convection Elements are on, measure amperage (approx 20

-23). Convection Fan will be on.

Press the Convection Broil key. Verify Broil & Convection Elements are on, measure amperage (approx 22 -

26). Convection Fan will be on.

Press the Pure Conv. key. Verify Conv. element is on, measure amps (approx 9-11). Conv. Fan will be on.

Press the Convection Roast key. Verify Convection Fan is on, measure amps (approx 0.1 - 0.8).

Home Screen Test Mode:

Press CANCEL key several time to exit Quick ERC/Diagnostic Test Mode or any other cooking mode. Be sure correct time of day is displayed then proceed with tests below.

Test Description Requirement

Membrane Check

Oven Lights

Cooling Fan

Function

Push each individual keys and verify audible beep. Press "CANCEL".

Press LIGHT 2 or more times and observe that light turns On and Off.

Press #, BAKE and then START. This will go to Sabbath mode. Verify that cooling fan is operational. Press

"CANCEL".

Door Latch Motor

Function

Close oven door and press SELF CLEAN key then START. Check door is locked once lock icon is on solid.

Immediately press the CANCEL key. Lock icon will disappear. Repeat for Lower Oven if Applicable

12/24 Hr Clock

Mode

12Hr Timer

Feature

C/F Setting

Lock Out

Press and hold CLOCK key for 6 seconds until the display shows "12HR" or "24HR". Toggle between

"24HR" and "12HR" using the # key. Factory setting is "12 HR".

Press and hold TIMER 1 key for 6 seconds until the display shows "12HR" and either "ON" or "OFF". Toggle between "ON" and "OFF" by pressing the # key. Factory setting is "ON".

Press BROIL key for 5 seconds. Press # key to toggle between "C" and "F". Factory setting is "F".

Press CANCEL-SECURE for 5 seconds. Verify membrane is locked out. Press CANCEL-SECURE again for

5 seconds. Verify membrane is operational.

PG: 16 Dacor Technical Assistance - (800) 353-2267

DACOR RENAISSANCE & DISTINCTIVE OVEN/RANGE ERROR CODES

Wall Models: EORS127, MORS127, EORD227, MORD227, EORS227, MORS227S, EORS130, MORS130, EORD230, MORD230, EORS230,

MORS230, RO130, ROV130, RO230, ROV230, DO130 & DO230

Range Models: RR30N, RR30NI, RR30NF, RR30NIF, DR30D. DR30DI & DR30E

Error Condition Software Logic Description Error Code

Control Errors

C01

C23

C24

C25

C33

C34

C35

C41

Shorted Key Failure Release of Key not seen in 2 mionutes. Membrane Shorted Key Failure

OCC Ambient Over

Temp

Control Board Ambient temp is above 80°C. Oven shuts down with the cooling fans turns ON until the ambient temp falls to 50°C. Possible Cause: Open door Broiling. Instruct customer to leave oven door shut during Broil.

Ambient Temp

Thermistor open

Ambient Temp

Thermistor shorted

Control Board Open thermistor detected.

Control Board Shorted thermistor detected.

OCC Ambient Over

Temp

Relay Board Ambient temperature is above 80°C. Oven shuts down with the cooling fans turns ON until the ambient temp falls to 50°C. Possible Cause: Open door Broiling. Instruct customer to leave oven door shut during Broil.

Ambient Temp

Thermistor open

Ambient Temp

Thermistor shorted

A/D Reference

Readings

Relay Board Open thermistor detected.

Relay Board Shorted thermistor detected.

Sensor value reading(s) - LSI Controller is checking sensor(s) over temp value are correct - ohm sensor(s), if ok replace LSI controller.

C42

E2 Checksum Failure on Control board

E2 - Checksum failure in LSI controller - Calculated checksum does not agree with stored checksum, replace LSI controller.

C43

Not all of the pin connectors from the wire harness are making contact with their respective terminal at

Wire Connection Error the Control and/or Relay Boards. Check to make sure that all pins are seated properly in to the Molex at Control and/or Relay plug and that each connector is properly making contact with the correct terminal at the Control and/or

Board Relay Board. Wires to Relay Board and Controller should ONLY be removed with POWER OFF to

unit or C43 WILL occur. This error is not reversible. Controller will need to be replaced.

C44

Checksum Failure on

Control board

Calculated FLASH checksum does not agree with the stored FLASH checksum.

C76

C77

Incorrect oven type:

Single/Double

No Connection to

Keypad

Displays error after 3 seconds of sensing an incorrect configuration. Ex: Double Oven Controller installed in Single oven. This error is reversible.

Keypad detection error. Check connection at Capacitive Touch Panel

Oven Errors U = UPPER OVEN / L = LOWER OVEN

U20 / L20

U21 / L21

U30 / L30

U31 / L31

Cook over temp

Clean over temp

Open RTD

Shorted RTD

Center of oven cavity temperatures above the maximum bounds of 610°F.

Center of oven cavity temperatures above the maximum bounds of 890°F.

Fatal Error. Continuous A/D values over maximum bounds.

Fatal Error Continuous A/D values over minimum bounds.

U50 / L50 Latch Lock Failure Fatal Error. The door lock is not detected while locking the door.

U51 / L51

U55 / L55

U80

Latch Phase Failure The door phase switch (LATCH NC) is not detected while locking the door.

Latch Motor Failure

Latch Motor not running. Check for power supplied to latch motor. If power is supplied to motor but will not run, replace latch assembly. Otherwise, trace wires to find failure.

Shorted meat probe The meat probe for the upper oven is shorted

PG: 17

Renaissance Induction Range - Induction Generator Technical Features

Renaissance Induction Range Models: RR30NS, RR30NIS, RR30NFS & RR30NIFS

Induction Generators:

Each Induction Generator Assembly consists of two burners (front and rear) and each operates as a separate circuit. Left and Right side Generator Assembly, Touch Control, Ribbon Cable and Wiring are separate but identical which will assist in your diagnostic procedure.

So, essentially there is two of everything. Utilizing “Process of Elimination” tactics, a Technician can easily and quickly diagnose failed components using functional components from the working

Generator side.

System’s Check:

When power supply is turned off and then turned back on the Induction Cooktop Generators will go through a “system’s check” process. This can be observed on any unit by viewing the Power Level LED indicators. The Generators will beep and the Power Level LED will count up from 1 to 9 then go blank.

Error Codes:

Error Codes will not be displayed to the user, but will be stored for later retrieval by Technicians.

The Generator may continue to operate through some very brief error conditions, or the generator will shut down when the error condition persists. When the Error Codes are called up, the 7-segment,

Power Level LED will alternately display “F” and a numeric error indicator at ½ second intervals. A

“System’s Check” (described above) will reset any Error Codes as long as the condition has been remedied.

Safety Features

 The generator will reduce wattage when the glass temperature reaches 300ºC. The wattage reduction will keep glass near but not over 300ºC to prevent oil fires and protect during dryboil.

 When pot is taken off of the inductor while in use or if inductor is turned on with no pot present, the inductor will de-energize and 7-segment LED will blink on its current setting for 30 seconds then turn off. If the pot is placed back on the inductor within 30 seconds the inductor will energize and the LED will stop blinking.

 The inductor will not energize if a small utensil (such as a knife or wedding ring) or an unacceptable pan (such as aluminum) is placed on the inductor instead of a steel or iron pot.

 The On/Off LED will light up whenever the associated inductor is energized.

 The Hot Surface Indicator (HSI) LED for an inductor will light up when the glass temperature reaches 105ºC and will extinguish when the glass temperature cools below 65ºC.

Selecting Proper Cookware:

 Always use utensils that have flat bottoms. Use utensils that best match the surface unit size

(smaller utensils on smaller surface units) and are a minimum of four inches in diameter.

 Use medium to heavy-gauge metal cookware with flat and smooth bottoms. Also choose cookware that closely matches the diameter of the cooking zone. Use utensils with tight fitting lids to retain heat, odors and steam.

 There will be some variation in the efficiency of the pots being used. All brands do not behave in exactly the same way since the different metals used conduct the electromagnetic waves from the induction elements differently. o Compatible Cookware: Stainless Steel with metal bottom, Enameled Iron or Steel, Cast Iron o Non-Compatible Cookware: Copper, Glass, Aluminum, Pottery

Dacor Technical Assistance: 800-353-2267

PG: 18

Renaissance Induction Range – Cooktop Error Codes

Models: RR30NS, RR30NIS, RR30NFS & RR30NIFS

 Error Codes will not be displayed to the user, but will be stored for later retrieval by a Technician.

 The Induction Generator may continue to operate through some very brief error conditions, or the generator will shut down when the error condition persists.

 When the Error Codes are called up, the 7-segment, Power Level LED will alternately display

“F” and a numeric error indicator at ½ second intervals. The Generator Fan will activate.

 Error Code Cycle and Fan will automatically cancel after 10 seconds.

 When condition is corrected and unit power supply is turned off and back on, the error code will be eliminated. If condition was not corrected, the code will reappear/reinitiate.

Note: Each Induction Generator Assembly consists of two burners (front and rear). Left and Right side Generator Assembly,

Touch Control, Ribbon Cable and Wiring are separate but identical which will assist in your diagnostic procedure.

The Cooktop Error Codes may be accessed as follows (16/22 Generator):

Touch the Left or Right side (front and rear zone) “HIGH” Preset Keys and hold for 6 seconds with the generator in

Standby (powered but no zones running). The last two Error Codes produced by the generator will be displayed in the

Power Level Display.

Error Code

F0

Definition

No Error Codes

Proposed Solution

None

F1

F2

F3

F4

F5

F6

Rear Induction NTC* shorted Replace Induction Generator Assembly

Rear Induction NTC* open

Front Induction NTC* shorted Replace Induction Generator Assembly

Front Induction NTC* open

Power Transistors shorted

Power Transistors open followed by “crawler” of horizontal segments

Electronics temp greater than

70ºC. Crawler will remain until temp is below 70ºC

F8

Front and rear zone NTC* connections reversed on

Induction Generator

Replace Induction Generator Assembly

Replace Induction Generator Assembly

Replace Induction Generator Assembly

Replace Induction Generator Assembly

Check: induction fan, airflow around generator, airflow through induction ductwork, open door broil, door hinges, door seal, damage to rear or bottom of range, etc.

Manufacturing error – Replace Induction Generator Assembly

F9

FA

FB

Supply Voltage below 180Vac. Check power supply from main

Communications Error has occurred

Check ribbon connection at touch control and generator; Check touch control connection at cooktop glass; Utilize “Process of Elimination” tactics to determine root cause of Error Code. Each left and right side

Induction Generator circuit is separate; from the power supply terminal block to the touch control. Utilize components from working side to diagnose non-working side.

Indicator LED Voltage error Check power supply from main; Check ribbon connection at touch control and generator; Check touch control connection at cooktop glass; Utilize “Process of Elimination” tactics to determine root cause of Error Code. Each left and right side Induction Generator circuit is separate; from the power supply terminal block to the touch control.

Utilize components from working side to diagnose non-working side.

*Negative Temp Coefficient

Dacor Technical Assistance: 800-353-2267

PG: 19

Dishwasher Factory Test Mode

24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S & MDH24S

30” Models: ID30, ED30SCH, ED30SCP, ED30SBK & ED30SBR

Factory Test Mode:

The Factory Test Mode, or FTM, is run on each unit during final QC to ensure that all of the components are operating normally. The FTM runs the unit through an abbreviated wash cycle and checks various sensors for response and is a valuable diagnostic tool. By knowing the timing of the FTM (shown below), a technician can check for operation of the component in question at the expected time.

MAKE SURE THAT THE UNIT IS SAFE TO OPERATE, AND ALL PLUMBING

CONNECTIONS ARE MADE PRIOR TO RUNNING THE FACTORY TEST MODE.

To Enter the FTM:

1. Press the SECURE key for three (3) seconds. Then press the SECURE key again for three (3) seconds to exit the secure mode.

2. Press DELAY and SANI RINSE keys simultaneously to start the factory test mode.

3. Close the dishwasher door. Be sure to close the detergent dispenser prior to initiating the FTM to check for proper operation.

4. All LED’s on the dishwasher will turn ON for about 15 seconds then turn off.

5. The factory test will begin. Use the timing chart below for expected operation timing of the component in question.

If during the FTM one of the electric components fails to operate at the scheduled time, it is likely that either the component has failed, the wiring has failed or the Power Board has partially failed. Start by checking the component in question and working back to the Power Board. Use extreme caution when working with live components.

After test has been completed, press CANCEL key once to exit from the factory test mode. To exit the factory test mode at anytime, press the CANCEL key once.

If the FTM has completed without error, a solid green light at the bottom of the door (ED model only) and three beeps will signal that all the major components are operating correctly.

Below is a timing schedule for the factory test:

Component

Drain Pump

Inlet Valve

Pause

Duration Comments

30 sec Control Board Version Displayed

60 sec Power Board software1 version displayed

20 sec Power Board software2 version displayed

Circ Pump & Heater 300 sec

Dispenser 5 sec

Drain Pump 30 sec

PG: 20 Dacor Tec-Line: 800-353-2267

Dishwasher Fault Codes:

24” Models: ID24, ED24SCH, ED24SCP, ED24SBK, ED24SBR, PD24 (all colors), MDV24S &

MDH24S

Fault Cause Effect Solution

F-1

F2

Pressure Switch is in the closed position after two full drain procedures.

Inlet Valve does not close.

Three long beeps. F1 will be displayed only during the Diagnostic mode.

Press Cancel key twice to reset this fault. Replace Pressure Switch.

Three long beeps. F2 will be displayed to the user and in Diagnostic mode.

Drain pump is ON until open door.

Press Cancel key twice to reset this fault Replace Inlet Valve. Replace control board.

F3 Low inlet water pressure. Three long beeps. F3 will be displayed to the user and in Diagnostic mode.

F4

F9

No response signal from the

WPS.

Heater failure

Wash cycle will go into a de-fault time table soil 3 & temp 0. F4 will be displayed only during the Diagnostic mode.

Temperature does not in-crease. Wash cycle will go into a default time table for

Heater ON time. F9 will be displayed only during the diagnostic mode.

30” Models: ID30, ED30SCH, ED30SCP, ED30SBK & ED30SBR

Fault Cause Effect

F-1

F2

Pressure Switch is in the closed position after two full drain procedures.

Inlet Valve does not close.

Three long beeps. F1 will be displayed only during the Diagnostic mode.

Three long beeps. F2 will be displayed to the user and in Diagnostic mode.

Drain pump is ON until open door.

Press Cancel key twice to reset this fault. Ensure that Inlet hose is ON.

Replace Flow Meter. Replace Inlet

Valve.

Check WPS connection Replace

WPS.

Replace heater. Replace WPS.

Replace Control board.

Solution

Press Cancel key twice to reset this fault. Replace Pres-sure Switch.

Press Cancel key twice to reset this fault Replace Inlet Valve. Replace control board.

F3 Controller failure to communicate with the Power

Board

Fault will be visible in the first three seconds of initial power-up. “F3” will flash on the display. Dishwasher will be disabled

Check control and power board compatibility and the wire harness between the two. Replacement of the control and power boards will be necessary if problem persists.

Check WPS connection Replace

WPS.

F4

F9

No response signal from the

WPS.

Heater failure

Wash cycle will go into a de-fault time table soil 3 & temp 0. F4 will be displayed only during the Diagnostic mode.

Temperature does not in-crease. Wash cycle will go into a default time table for

Heater ON time. F9 will be displayed only during the diagnostic mode.

Replace heater. Replace WPS.

Replace Control board.

24” Millennia Models: MDW24S & EDW24S

Display Codes (Readout)

LO Low Liquid in the Rinse Aid Dispenser

PF A Power Failure has occurred

HO Water Heating Delay

CL Close and latch the door

01-04 Hours delay before the dishwasher will start

CF Clean Filters

Dacor Tec-Line: 800-353-2267

PG: 21

Dishwasher Diagnostic Quick Reference Sheet.

Distinctive Model: DDWF24S

To activate the service menu

1. Turn off the main power switch (I/0)

2. Wait at least 5 seconds

3. Press and hold the Program and Start buttons (S1 & S2)

4. Switch on the main power switch (I/0)

5. Release the Program and Start buttons (S1 & S2) L7 flashes

Press S1 to activate the component test. These are activated in order after each button press:

1. Inlet valve and mixer valve (mixer valve open 1 second then inlet valve open, after next press of S1 both valves closed 1 second then only inlet valve open)

2. Salt water valve (salt and mixer valve only in machines with water softener)

3. Detergent dispenser

4. Circulation pump

5. Circ. pump and element (max. 75°C/167°F)

6. Fan and Wax Motor (if equipped)

7. Drain pump

Epicure Model: EDWH24S Integrated Model: IDWH24

S1 L1 L2 L3 L4 L5 L6 S3 S4 S5 S6 S7 L7 L10 S2

L8 L11

To activate the service menu

1. Turn off the main power switch (I/0)

2. Wait at least 5 seconds

3. Press and hold the Cycle and Start buttons (S1 and S2)

4. Switch on the main power switch (I/0)

5. Release the Cycle and Start buttons (S1 and S2) L10 and L11 flash.

Most recent fault indicated by L1-L6.

Press S1 to activate the component test. These are activated in order after each button press:

1. Inlet valve and mixer valve (mixer valve open 1 second then inlet valve open, after next press of S1 both valves closed 1 second then only inlet valve open). L1 and L2 lit

2. Salt water valve (salt and mixer valve only in machines with water softener). L3 lit

3. Detergent dispenser. L4 lit

4. Circulation pump. L5 lit

5. Circ. pump and element (max. 75°C/167°F). L6 lit

6. Fan and Wax motor. L1 and L2 lit

7. Drain pump. L1, L2 and L3 lit

PG: 22

Dacor Tech Line: 800-353-2267

Dishwasher Control Programming and Fault Code Reference Sheet

Control Programming DDWF24S

When the power is switched on for the first time after replacing the control unit, the Variant settings menu is displayed.

L4 flashes (Control with one option: Temp)

1. Press the Program button (S1) until Variant 2 (L4 flashes).

2. Confirm your selection by pressing Start (S2). (The program automatically returns to the main menu.)

Control Programming EDWH24S & IDWH24

When the power is switched on for the first time after replacing the control unit, the Variant settings menu is displayed.

1. Press the Cycle button (S1) until the desired Variant is selected:

L1 flashes: Variant1 = Time saver

2. Confirm your selection by pressing Start (S2).

The machine detects the presence of a turbidity sensor, a pressure sensor and a spray arm diverter. The program returns to the main menu.

To reset the machine to its factory settings:

1. Turn off the main power switch (I/0)

2. Wait at least 5 seconds.

3. Press and hold the Cycle button (S1)

4. Switch on the main power switch (I/0)

5. Release the Program button (S1).

L1 and L4 flash during the reset process (DDWF24S). The machine will reset various settings, although not water hardness, and then automatically return to the main menu. Detects the presence of a pressure sensor.

Fault Codes:

L1 Temperature Fault Stop (DDWF24S no indication)

Possible Cause: Temperature increase less than 5°C/41°F in ten minutes. Program continues with the process.

Only indicated in service menu. Check: Element, thermistor, water level, circulation pump, control unit and cables.

L2 Overfilling

Possible Cause: Too much water in the machine (pressure sensor) or float activated. If the water has not been emptied within 60 seconds, the program stops (drain pump activated). Check: Drain pump (blocked hose), flow meter, inlet valve, leaks and cables.

L3 Thermistor Fault (DDWF24S no indication)

Possible Cause: Stopped or less than 80°C/176°F. Program continues with the process. Only indicated in service menu.

Check: Thermistor and control unit.

L4 Water Intake Fault (DDWF24S no indication)

Possible Cause: Less than 80 pulses within 60 seconds or correct number of pulses not achieved within 255 seconds.

Program stops.

L5 Leaking valve - Check: Water inlet, flow meter, inlet valve and cables.

Possible Cause: Water intake detected when inlet valve deactivated. Any current program stopped (drain pump activated). Check: Leak through inlet valve and flow meter.

L6 Pressure sensor fault (DDWF24S no indication)

Possible Cause: Output signal greater than 4.8 V. The program continues. Only indicated in service menu. Check:

Pressure sensor, control unit and cables.

L7 Drain fault (DDWF24S no indication)

Possible Cause: Water not drained after 120 seconds draining. Program stops. Check: Drain pump, hoses, drain hose fittings, control unit and cables. Also check whether filter is blocked.

FA Turbidity sensor fault - L1 and L5 Flash (DDWF24S no indication)

Possible Cause: Only indicated in service menu. The machine assumes high turbidity in case of “uncertainty” in the auto program. Check: Water quality, filters, turbidity sensor and drain system.

FB Spray arm diverter fault – L1 and L6 Flash (DDWF24S no indication)

Possible Cause: Position switch always closed or open. The program continues. Only indicated in service menu. Check:

Spray arm diverter (functioning gearbox, switches and cables).

Dacor Tech Line: 800-353-2267

PG: 23

Dacor 36” Freestanding Refrigerator Programming and Diagnostics:

Models: EF36BNDFSS, IF36BNDFSF, EF36LNDFSF, EF36RNDFSS, IF36INDFSF, EF36BNFSS, EF36LNFSS,

EF36RNFSS, & EF36BNNFSS and PF36BNDF (all colors: AG, BK, BU, GN, SG and TS).

Programming Mode: Note: The Programming Code is located on the Serial Plate.

1. Press and Hold the “Door Alarm” Keypad.

2. Press and hold the Freezer Temperature Down Keypad.

3. Release the “Door Alarm” Keypad and wait 3 seconds.

4. The Control will display “PE” to indicate the Programming Mode.

5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more.

6. The Control will display the current Program Code. This code should be validated with the Program Code printed on the Serial Plate. If the Program Code is correct, the Program Mode can be exited by closing the Refrigerator Door(s).

7. Press the Refrigerator Temperature Up or Down Keypad to change the digit value with each press.

8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to select the next digit.

9. Once the desired Program Code is entered, press and hold the Freezer Temperature Down key until the Program

Code begins flashing indicating it has been saved.

Note: If you attempt to enter an invalid Program Code the control will not save the new code, but will beep (the unit will not run with a Program Code of 0000). Once the Program Code has been saved the Programming Mode is exited by closing the Refrigerator Door(s). If the new code is not correct this process should be repeated after closing the

Refrigerator Door(s).

Forced Defrost Mode:

The forced defrost function is performed using the refrigerator display and keypad. Enter the Forced Defrost Mode by the following:

1. Press and Hold the “Door Alarm” Key.

2. Press and Hold the Refrigerator Temperature Down Keypad.

3. Release the “Door Alarm” Keypad and wait 3 seconds. Fd appears in left display.

4. Press the Refrigerator Down Keypad again. Sh appears in the right display.

5. Press again to force defrost, Fd and Sh will flash in Display indicating unit is in defrost.

Service Test Mode:

To enter the Service Test Mode follow these directions.

1. Open the Fresh Food Door and press and hold the “Door Alarm” Keypad.

2. Press and Hold Refrigerator Temperature Up Keypad.

3. Release the “Door Alarm” Keypad and wait 3 seconds. SE appears in the left display.

4. Press the Refrigerator Up Keypad again.

5. Display will show 001 in the left display and numeric or dashes in right display. Test # 001 is for Factory Use Only.

6. Press Freezer Up Keypad and Freezer Down Keypad to toggle through Service Test Number.

Service Test 001 – Factory Use Only

Service Test 101 – Defrost Heater & Defrost Circuit Test

Press the Refrigerator Up Keypad and Refrigerator Down Keypad to energize or de-energize the Defrost Circuit. The display will read OFF when de-energized, OP when energized with an open defrost thermostat and CL when energized with a closed defrost thermostat.

Service Test 102 – Compressor/Condenser Fan Test

Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Compressor/Condenser Fan On and Off.

Service Test 111 – Fresh Food Fan Test (if equipped)

Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle the Fresh Food Fan On and Off. Note:

Display will show state OFF or DC Voltage

Service Test 112 – Evaporator/Freezer Fan Test

Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle the Fresh Food Fan On and Off. Note:

Display will show DC Voltage.

PG: 24

Service Test 121 – Open Damper Test

Press the Refrigerator Up Keypad and Down Keypad to toggle Damper (OP) open and (CL) Closed. Note: If Damper is opening or closing it will not allow you to toggle damper and will beep. Display will show –CL or –OP if Damper is in the process of closing or opening.

Service Test 131 – Mullion Heater 3 Door Models

Press the Refrigerator Up Keypad and Down Keypad to toggle Mullion Heater On or Off.

Service Test 141 – Fresh Food Thermistor Test

Display will show Fresh Food Temperature or OP for Open Thermistor or SH for Shorted Thermistor.

Service Test 142 – Freezer Thermistor Test

Display will show Freezer Temperature or OP for Open Thermistor or SH for Shorted Thermistor.

Service Test 143 – Machine Compartment Thermistor

Display will show Machine Compartment Temperature or OP for Open Thermistor or SH for Shorted Thermistor.

Service Test 151 – Fresh Food Door Switch State

Will show the state of the Fresh Food Door Switch(s). OP (open) or CL (closed).

Service Test 152 – Freezer Door Switch State

Will show the state of the Freezer Door Switch(s). OP (open) or CL (closed).

Service Test 174 – Water Actuator; Internal Dispenser

Display shows the state of the Internal Water Dispenser (ON or OFF). By pressing and releasing the Actuator Pad you can turn the inlet valve on and off.

Service Test 181 – Keypad Operation

Display shows a numeric or letter display indicating the last key pressed.

Service Test 182 – LED Indicator Operation

Press the Refrigerator Up Keypad to show the operation of the LED Indicators. All LED Indicators will Flash. Press twice and all LED’s will stop flashing.

Service Test 191 – Ice Maker Water Valve

Display shows the state of the Ice Maker Water Valve (ON or OFF).

Service Test 201 – Million Heater 100% Operation (if equipped)

Press the Refrigerator Up Keypad and Down Keypad to toggle Mullion Heater On or Off.

Service Test 202 – Defrost Operation

Press the Refrigerator Up Keypad and Down Keypad to toggle Defrost Operation to minimum time between defrosts

On or Off.

Service Test 203 – Factory Use Only

Service Test 211 – Fresh Food Temperature Adjustment

Press the Refrigerator Up Keypad and Down Keypad to adjust temperature set points +6˚ to -6˚. Note: this adjustment works in reverse. A -4 setting will increase the temp 4˚F. A +4 setting will decrease temp 4˚F.

Service Test 212 – Freezer Temperature Adjustment

Press the Refrigerator Up Keypad and Down Keypad to adjust temperature set points +6˚ to -6˚. Note: this adjustment works in reverse. A -4 setting will increase the temp 4˚F. A +4 setting will decrease temp 4˚F.

Service Test 221 – Default Settings Reset

Press the Refrigerator Up Keypad to activate.

Service Test 231 - Water Filter Volume (% consumed)

Display shows volume % consumed since installed.

Service Test 232 - Water Filter Time Life

Displays days filter used since installed

Service Test 241 – Software Revision of Main Control

Display shows Software Revision of Main Control

Service Test 242 – Software Revision of Main Display

Display shows Software Revision of Main Display

Service Test 243 – Software Revision Dispenser

Display shows Software Revision Dispenser

Dacor Technical Assistance: 800-353-2267 PG: 25

Dacor 36” Water/Ice Dispenser Freestanding Refrigerator - Programming and Diagnostics:

Model: EF36IWFSS

Control Panel Touch Pads

Programming Mode:

NOTE: The Program Code is located on the Serial Plate after the word Code.

1. Press and hold the WATER Keypad.

2. Press and hold LL Keypad.

3. Release the WATER Keypad and wait 3 seconds.

4. The control will display PE to indicate the programming mode.

5. Entry is confirmed by pressing the LL Keypad once more.

6. The control will display the current Program CODE. This value should be validated with the Program CODE printed on the unit serial plate. NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing water Keypad for 3 seconds.

7. Press the UR Keypad or LR Keypad to change the digit value with each key press.

8. The decimal point indicates the selected digit. Press the UL Keypad to select the next digit.

9. Once the desired Program CODE is entered, press and hold the LL Keypad until the Program CODE begins flashing indicating it has been saved.

NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a

Program CODE of 0000). Once the Program CODE has been saved the Programming Mode is exited by pressing any key or by opening or closing the refrigerator door. If the new code is incorrect this process should be repeated.

Forced Defrost Mode:

Enter the Forced Defrost Mode by performing the following sequence of events:

1. Press and hold the WATER Keypad.

2. Press and hold LR Keypad.

3. Release the WATER Keypad and wait 3 seconds. Fd appears in the left side of the display.

4. Press the LR Keypad again. Sh appears in right side of the display.

5. Press LR again to force defrost Fd and Sh will flash in display indicating unit is in defrost.

Service Test Mode:

Enter the Service Test Mode by performing the following sequence of events:

1. Press and hold the WATER Keypad.

2. Press and hold UR Keypad.

3. Release the WATER switch and wait 3 seconds.

4. The display will show SE confirming entry in the Service Mode.

5. Press the UR Keypad again to confirm entry in the Service Mode.

6. Display will show 101 in left display and numeric or dashes in right display.

7. Press UL Keypad and LL Keypad to toggle through Service Test numbers.

8. To exit service test mode, open and close refrigerator door or hold door alarm for 3 seconds.

Service Test - 101 Defrost Heater & Defrost Circuit

• Press the UR keypad or LR keypad to energize or de-energize the Defrost circuit. The display will read OFF when de-energized, OP when energized with open defrost thermostat and CL when energized with closed defrost thermostat.

Service Test - 102 Compressor / Condenser Fan

• Press the UR keypad or LR keypad to toggle Compressor/Condenser fan On and Off.

Service Test - 112 Freezer Fan

• Press the UR keypad or LR keypad to toggle Freezer Fan On High speed, Low speed and Off. NOTE: Display will show state 0.0 for OFF, 11.0-

14.0 volts for High speed or 7.75- 8.25 volts for Low speed.

Service Test - 113 Ice Compartment Fan

• Press the UR keypad or LR keypad to toggle Ice compartment Fan On High speed, Low speed and Off. NOTE: Display will show 0.0 for OFF,

11.0-14.0 volts for High speed or 7.75- 8.25 volts for Low speed.

Service Test - 121 Damper Operation

• Press the UR keypad or LR keypad to toggle Damper OP open and CL closed. NOTE: When damper is opening or closing it will display -- if damper state is unknown. It can also show DP if damper is moving when initially entering service mode.

Service Test - 131 Mullion Heater

• Press the UR Keypad or LR Keypad to toggle Mullion Heater Off and On.

Service Test - 141 Fresh Food Thermistor

• Will Show Fresh Food Temperature or OP for open thermistor or SH for shorted thermistor.

Service Test - 142 Freezer Thermistor

• Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor.

Service Test - 144 Ambient Thermistor

• Will Show Ambient Temperature or, OP open thermistor or SH shorted thermistor.

Service Test - 145 Ice Box Thermistor

• Will Show Ice Box Temperature or, OP open thermistor or SH shorted thermistor.

PG: 26

Service Test - 151 Fresh Food Door State

• Will show state of Fresh Food Door. OP (open) CL (closed). NOTE: By pushing either fresh food door switches you can toggle from OP to CL.

Service Test - 152 Freezer Food Door State

• Will show state of Freezer Door. OP (open) CL (closed). NOTE: By pushing freezer door switch you can toggle from OP (open) to CL (closed).

Service Test - 153 Disable Internal Lights

• Press the UR keypad or LR keypad to toggle Enable En and Disable dIS internal lights.

Service Test - 163 Water Dispenser

• Display shows the state of the Water Dispenser Valve (On or OFF). NOTE: By pushing Actuator pad or Express Fill keypad you can control Water

Dispenser Valve.

Service Test - 164 External Ice Chute Door

• Display shows the state of the External Ice Chute Door CL (closed) or OP (open). NOTE: By pushing Actuator pad you can control state of

External Ice Chute Door.

Service Test - 165 Dispenser Lamp

• Display shows the state of the Dispenser Lamp (On or OFF). NOTE: By pushing Actuator or Express Fill keypad you can control dispenser lamp.

Service Test - 167 Cavity Heater Test (On some models)

• Toggles the state of the Cavity Heater On or OFF. NOTE: Pushing UR or LR keypads toggles the cavity heaters state to On or OFF

Service Test - 168 Cube Dispenser and Internal Ice Chute Door Operation

• Display shows the state of the ice auger motor and the internal ice chute door. (On or OFF) NOTE: By pushing actuator pad you can control state of the Ice auger motor and the internal ice chute door.

Service Test - 171 Actuator Pad

• Display shows the state of the Actuator Pad (On or OFF).

Service Test - 172 Front Fill (On some models)

• Display shows the state of the Front Fill (On or OFF).

Service Test - 173 Ambient Light

• Display shows light sensor measurement (Hi or Lo). Night light will turn on when light sensor measures Lo. By changing the sensor's exposure to ambient light you can control the sensor measurement.

Service Test - 175 Dispenser Switch

• Display shows the state of the Dispenser Switch (On or OFF). NOTE: By pushing Actuator pad or Express Fill keypad you can change state of

Dispenser Switch.

Service Test - 182 LED Indicator Operation

• Press the UR or LR keypads to show operation of LED Indicators. All LED’s will flash. Press again and LED will stop flashing.

Service Test - 183 Keypad Operation

• Display shows a numeric or letter display indicating the last key pressed. NOTE: UR and LR keypads have no effect when pressed and UL and LL keypads remain operational.

Service Test - 192 Ice Maker State Test

• Display shows dr if left fresh food door switch is in the door open position.

• Display shows OFF if ice maker power switch is in the off position and door closed.

• Display shows On if the ice maker power switch is in the on position and the door closed and heater is off.

• Display shows OnH if icemaker power switch is in the on position and harvest heater is on and door closed.

Service Test - 193 Ice Maker Relay

• Press the UR Keypad or LR Keypad to toggle the ice maker relay On and OFF.

*NOTE: Service tests 201-213 modify factory settings to suit customer's needs.

Service Test - 201 Mullion Heater Override

• Press the UR or LR Keypad to change Mullion Heater from cycling on with compressor (OFF position) to 100% operation (On position). NOTE: If present, the Humidity Control Button toggles between the selected Mullion Heater Function and 0% operation.

Service Test - 202 Default Defrost Operation

• Press the UR or LR Keypad to change Defrost Operation from normal adaptive (Off position) to minimum time between defrosts (On position).

Service Test - 203 Show Temp Set points - Disregard this Test - Unit will not display actual temp only set temp.

Service Test - 211 Fresh Food Temperature Adjustment

• Press the UR or LR Keypad to change calibration of Fresh Food Temperature plus or minus in 1°F increments up to 6°F. Note: this adjustment works in reverse. A -4 setting will increase the temp 4°F. A +4 setting will decrease temp 4°F.

Service Test - 212 Freezer Temperature Adjustment

• Press the UR or LR Keypad to change calibration of Freezer Temperature plus or minus 1°F in increments up to 6°F. Note: this adjustment works in reverse. A -4 setting will increase the temp 4°F. A +4 setting will decrease temp 4°F.

Service Test - 213 Ice Compartment Temperature Adjustment

• Press the UR or LR Keypad to change calibration of Ice Maker Compartment Temperature + or - 1°F in increments up to + 8°F. Note: this adjustment works in reverse. A -4 setting will increase the temp 4°F. A +4 setting will decrease temp 4°F.

Service Test - 221 Reset Default Settings

• Press the UR or LR Keypad to reset to factory default settings dEF.

Service Test - 231 Water Filter Usage

• Display shows the percent water filter consumption since water filter was reset. 100% indicates the filter should be replaced.

Service Test - 232 Water Filter Days In Use

• Display shows the number of days since the water filter was reset.

Service Test - 241 Software Revision Main Control Board

• Display shows the Software revision of the Main Control Board.

Service Test - 244 Software Revision Display Board

• Display shows the Software revision of the Display Board.

NOTE: Service tests 3XX and above are reserved for Engineering Use Only.

Dacor Technical Assistance: 800-353-2267

PG: 27

Dacor 42” and 48” Built-in Refrigerator Diagnostics (First Generation - Classic):

Models: EF42BDCBSS, EF42BNDBSS, IF42BNDBOL, IF42BDCBOL, EF48BDCBSS,

EF48BNDBSS, IF48BNDBOL, IF48BDCBOL

Service Test Mode

There are several test modes available through the diagnostic system. Use of these test modes can greatly decrease the time needed for troubleshooting. It is to the service technician’s advantage to be able to perform many tests in a very short period of time.

Within the Service Test Mode the controls have alternate functions. The FREEZER up and down buttons (arrows) will move to the next or the previous service test. If you are at Service Test 4 and press the FREEZER up arrow you will move to Service Test 5.

The REFRIGERATOR up and down arrows will move you through the service tests ten steps at a time. If you are at Service Test

4 and press the REFRIGERATOR up arrow you will move to Service Test 14.

The POWER INTERRUPT button will activate the selected Service Test. At every test, after selecting the test number with the up and down arrows, you must activate the test using the POWER INTERRUPT button. In many cases the display will change and provide you with additional information for that particular test. To end a test and return to the test selection menu, tap the POWER

INTERRUPT button again.

To enter the Service Test Mode, the door switches must be held in the door closed position. It would be easiest to tape the switch in the closed position.

Tap the POWER INTERUPT icon three times in succession. The system will switch to the service mode and show the current mode as NORMAL or no in the fresh food temperature display. If the system shows a different indication this indicates that the

unit was not in the normal operating mode.

Pressing The FREEZER up arrow will change the display to Sh. This is the Showroom mode. If the Power Interrupt button is tapped at this point, the system will be in the showroom mode. While in the showroom mode, the lights and display operate but the cooling system does not energize.

Pressing the FREEZER up arrow again will change the display to SE. This is the entrance to the SErvice Tests. Tapping the

Power Interrupt button will place the unit into service mode and the display will change to 00 00 with the word service illuminated in the display.

From this point forward the up and down arrows are used to move forward or backwards through the Service Tests. The Power

Interrupt Button will activate the service test.

If the service mode starts at any location other than 00 00 it is an indication that the Service Tests mode was not properly exited when last serviced.

Service Test 01 – Software Revision

This test will allow you to view the current software version installed on the refrigerator. At the current time there is no method to update the software in the field. Pressing the Power Interrupt Button will display the current software version. Pressing the Power

Interrupt Button will return you to the previous screen.

Service Test 02 – High Ambient Override

This is not really a test but a system setting for special operating conditions. By activating the High Ambient override you will alter the temperature control programming. This setting should only be used in cases of high temperatures and high humidity.

Pressing the Power Interrupt Button will activate this setting. When activated the WORKING lamp will illuminate. The working lamp will return to normal operation when you exit the Service Tests Mode.

Upon reentry and selecting Service Test 02 the lamp will indicate whether the High Ambient Override is activated. Pressing the

Power Interrupt Button will deactivate the High Ambient Override.

PG: 28 Dacor Technical Assistance: 800-353-2267

Continued… Dacor 42” and 48” Built-in Refrigerator Diagnostics (First Generation - Classic):

Models: EF42BDCBSS, EF42BNDBSS, IF42BNDBOL, IF42BDCBOL, EF48BDCBSS, EF48BNDBSS, IF48BNDBOL, IF48BDCBOL

Thermistor Tests: This test will give a “GO – NO GO” test of all thermistors. Pressing the Power Interrupt Button will report the condition of the thermistor. Note: The condition displays that follow apply to the tests for all thermistors.

Service Test 03 – Fresh Food Thermistor

PA=Pass; oP=Open; Sh=Shorted

Service Test 04 – Freezer Thermistor

PA=Pass; oP=Open; Sh=Shorted

Service Test 05 – Evaporator Thermistor

PA=Pass; oP=Open; Sh=Shorted

Service Test 06 – Ambient Thermistor

PA=Pass; oP=Open; Sh=Shorted

Fan Tests: This test will give a “GO – NO GO” test of the Fresh Food and Evaporator Stirrer fans. Pressing the Power Interrupt

Button will result in one of the following displays. The fan will always initially display Lo for fan too slow. Let the fan spin up to speed for accurate test. This will only take a few seconds.

Service Test 07 – Fresh Food Fan

PA=Pass; Lo= Fan running too slow; Hi= Fan running too fast

Service Test 08 – Evaporator / Freezer Fan Test

PA=Pass; Lo= Fan running too slow; Hi= Fan running too fast

Service Test 09 – Open Damper Fresh Food Compartment

Tap the Power Interrupt Button and the damper will move to the open position. There is no change in the display while the damper opens. It takes between 7 and 15 seconds for the damper to move to the open position.

Service Test 10 – Close Damper Fresh Food Compartment

Tap the Power Interrupt Button and the damper will move to the closed position. There is no change in the display while the damper closes. It takes between 7 and 15 seconds for the damper to move to the closed position.

Service Test 11 – Defrost Heaters

If the defrost safety thermostat is closed the defrost system will draw approximately 3 amps. Pressing the Power Interrupt Button while at Service Test 11 will energize the defrost heaters. When the Power Interrupt Button is tapped the display will indicate the current evaporator temperature on the fresh food side of the display. The temperature should begin to quickly rise when the heaters are energized. This can be used to quickly determine if the defrost system is energized.

Service Test 12 – Condenser Fan

This test will energize the condenser fan. Pressing the Power Interrupt Button will activate the test. Line voltage should be present at JP13 pin 1.

Service Test 13 – Fresh Food Lights

This test will energize the fresh food lamps. Pressing the Power Interrupt Button will energize the fresh food light system. Line voltage should be present at JP12 pin 2.

Service Test 14 – Freezer Lights

This test will energize the freezer lamps. Pressing the Power Interrupt Button will energize the freezer light system. Line voltage should be present at JP 12 pin 3.

Service Test 15 – Fountain Lamp

This test will energize the fountain lamp (dispenser light). Pressing the Power Interrupt Button will energize the fountain lamp. Line voltage should be present at JP8 pin 9.

Service Test 16 – Compressor Maximum Speed

The compressor should have been off for at least five minutes prior to this test. If the off time is not five minutes, the short cycle protection within the compressor controller will prevent operation until enough time has elapsed. The Service Test may time out

(three minutes) before sufficient time has elapsed for the compressor to start. If the display changes back to this display (16 00) reactivate the test. Pressing the Power Interrupt Button will start the compressor at maximum speed. The display will show the current evaporator temperature on the fresh food side of the display. If the compressor is working, this temperature should quickly drop. If the compressor does not eventually start after waiting for at least five minutes check for the following conditions: JP10, pins 1 to 2, 2-2.5VAC this is the drive signal from the Main Control Board to the Compressor Controller. CN 05 pins 1 to 6,

230VAC, this is the output from the compressor controller to the compressor.

PG: 29

Continued… Dacor 42” and 48” Built-in Refrigerator Diagnostics (First Generation - Classic):

Models: EF42BDCBSS, EF42BNDBSS, IF42BNDBOL, IF42BDCBOL, EF48BDCBSS, EF48BNDBSS, IF48BNDBOL, IF48BDCBOL

Service Test 17 – Compressor Minimum Speed

The compressor should have been off for at least five minutes prior to this test. If the off time is not five minutes, the short cycle protection within the compressor controller will prevent operation until enough time has elapsed. The Service Test may time out

(three minutes) before sufficient time has elapsed for the compressor to start. If the display changes back to this display (17 00) reactivate the test. Pressing the Power Interrupt Button will start the compressor at minimum speed. The display will show the current evaporator temperature on the fresh food side of the display.

If the compressor is working, this temperature should quickly drop. If the compressor does not eventually start after waiting for at least five minutes check for the following conditions: JP10, pins 1 to 2, 2-2.5VAC this is the drive signal from the Main Control

Board to the Compressor Controller. CN 05 pins 1 to 6, 130VAC, this is the output from the compressor controller to the compressor.

Service Test 18 – Fresh Food Fan Speed

This Service Test will verify the feedback signal from the fresh food fan to the Main Control board. Pressing the Power Interrupt

Button will report the fan speed in revolutions per second. This reading would be 39 RPS.

Service Test 19 – Freezer Fan Speed

This Service Test will verify the feedback signal from the freezer fan to the Main Control board. Pressing the Power Interrupt

Button will report the fan speed in revolutions per second.

Service Test 20 – Fresh Food Thermistor Value

This test will provide the current reading for the fresh food thermistor. This reading is real time and should be very close to the actual temperature of the fresh food thermistor. If the reading is drastically different than the reading from a known good and calibrated digital thermometer, consider replacement of the thermistor. Consider any reading within 5 degrees of a known good calibrated thermocouple acceptable.

Service Test 21 – Freezer Thermistor Value

This test will provide the current reading for the freezer thermistor. This reading is real time and should be very close to the actual temperature of the freezer thermistor. If the reading is drastically different than the reading from a known good and calibrated digital thermometer, consider replacement of the thermistor.

Service Test 22 – Ambient Thermistor Value

This test will provide the current reading for the ambient thermistor. This reading is real time and does not involve the temperature control algorithm. This reading should be very close to the actual temperature of the ambient thermistor. If the reading is drastically different than the reading from a known good and calibrated digital thermometer, consider replacement of the thermistor.

Service Test 23 – Evaporator Thermistor Value

This test will provide the current reading for the evaporator thermistor. This reading is real time and does not involve the temperature control algorithm. This reading should be very close to the actual temperature of the evaporator. If the reading is drastically different than the reading from a known good and calibrated digital thermometer, consider replacement of the thermistor.

Service Test 24 – Display Temperature Select

This test reports the temperature selection switch as read by the board. Pressing the Power Interrupt Button will display the current setting. ˚F = Fahrenheit or ˚C = Celsius.

Service Test 25 – Fountain State

This test reports back the current status of the dispenser. If the dispenser control does not change the output, suspect data communication problems with the dispenser control itself. Pressing the Power Interrupt Button will indicate the current state of the dispenser.

Ld = Dispenser is Locked; ho = Dispenser set for Water; CS = Dispenser set for Crushed Ice; CU = Dispenser set for Cubed Ice.

Service Test 26 – Bypass Valve Switch

This test indicates the current state of the bypass switch. This switch must be reported as actuated for any of the water valves to operate. Pressing the Power Interrupt Button will display the current switch state.

in = Bypass plug is installed; OU = Bypass plug is not installed

Service Test 27 – Filter Valve Switch

This test indicates the current state of the filter switch. This switch must be reported as actuated for the filter monitor to operate.

Pressing the Power Interrupt Button will display the current switch state.

in = Filter is installed; OU = Filter is not installed

PG: 30

Continued… Dacor 42” and 48” Built-in Refrigerator Diagnostics (First Generation - Classic):

Models: EF42BDCBSS, EF42BNDBSS, IF42BNDBOL, IF42BDCBOL, EF48BDCBSS, EF48BNDBSS, IF48BNDBOL, IF48BDCBOL

Service Test 28 – Actuator Switch

This test displays the current state of the dispenser actuator (paddle switch) as read by the Main Control board. Pressing the

Power Interrupt Button will display the current state of the switch.

on = Switch activated OF = Switch released

Service Test 29 – Cube Solenoid

This test will energize the cube solenoid. Pressing the Power Interrupt Button will energize the cube solenoid when the Dispenser switch is also actuated.

Service Test 30 – Auger Motor

This test will energize the auger motor. Pressing the Power Interrupt Button will energize the motor when the dispenser switch is also actuated.

Service Test 31 – Chute Solenoid

This test will energize the chute solenoid. Pressing the Power Interrupt Button will energize the chute solenoid.

Service Test 32 – Water Valve

This test will energize the water valve(s) for the dispenser. Pressing the Power Interrupt Button will energize the water valve so long as the dispenser switch is activated.

Service Test 33 – Force Defrost and Exit

This test will initiate a defrost cycle and exit the Service Test Mode. Pressing the Power Interrupt Button will initiate the defrost cycle.

Release the door switch to return to normal operation.

FoodSaver™ TEST MODE

To perform the built-in diagnostics that test the FoodSaver™ module, both door switches must be closed. Tape the fresh food compartment door switch closed. With the door switches closed, the FoodSaver display should be blank.

To enter the FoodSaver test module, press and hold the Citrus and Produce keypads for five seconds.

The LCD should display –88 and be illuminated.

All keypads should be illuminated.

The fan should be off.

The damper should close

Wait seven seconds, touch the Citrus Keypad.

The fan will begin turning.

If the controller does not sense fan rotation, an F will be displayed.

The heater will energize.

If the control does not sense heater continuity, an H will be displayed.

The damper will open.

The display should be blank yet illuminated unless indicating an F or H.

The Citrus keypad should be illuminated.

Wait seven seconds, touch the Produce Keypad.

The control will test the thermistor circuit.

If the circuit is open, OC will show in the display.

If shorted, CC will show in the display.

The display should be blank yet illuminated unless indicating OC or CC.

The produce keypad should be illuminated.

Touch the Meat Keypad. (Not applicable to upper FoodSaver)

The meat keypad will illuminate.

Touch the Normal Keypad

This will exit the diagnostic mode.

The diagnostic mode will terminate if the refrigerator door switch is opened or if five minutes passes with no activity.

Dacor Technical Assistance: 800-353-2267 PG: 31

Dacor 36”, 42” and 48” Built-in Refrigerator Diagnostics (Second Generation):

Models: EF36LNBSS / EF36RNBSS / IF36LNBOL / IF36RNBOL / EF42NBSS / EF42DBSS / IF42NBOL /

IF42DBOL / EF48NBSS / EF48DBSS / IF48NBOL / IF48DBOL

Diagnostic Test Mode

There are several test modes available through the diagnostic system. Use of these test modes can greatly decrease the time needed for troubleshooting. It is to the service technician’s advantage to be able to perform many tests in a very short period of time.

Pre-Diagnostics Checks

• Confirm the refrigerator and freezer temperatures before beginning other checks.

• See if the compressor, evaporator, and condenser fans are running.

• Check the position of the air door.

Diagnostics Mode:

The Diagnostics Mode is used to:

• Check the refrigerator & freezer thermistors.

• Operate the evaporator fan motor at 3000 rpm.

• Operate the condenser fan motor and compressor.

• Check the defrost bimetal and heater.

To enter the diagnostics mode:

To enter the Diagnostics Mode, the control must be turned on, and be in a normal cooling mode.

Both the Power On/Off and the Water Filter Reset keys must be functional. The refrigerator display shows the step number. The results of the checks are displayed on the water filter status indicator. After 20 minutes, the control will default from the Diagnostics Mode to a normal cooling mode.

• Press and hold the Water Filter Reset keypad, and then immediately press and hold the Power keypad.

Continue to press both keypads for 3 seconds, or until you hear a beep.

To advance the Diagnostics Sequence:

• To advance to the next step in the sequence, press and hold the Water Filter Reset key for 2 seconds or until you hear a beep. The Diagnostics Chart on the next page shows the step number and the component being tested in each step.

SERVICE TIP: If the control does not respond, it may be necessary to remove power from the entire appliance for a few seconds. Reapply power and perform the service diagnostics routine again to verify that the control is working properly.

Dacor Technical Assistance: 800-353-2267

PG: 32

Continued… Dacor 36”, 42” and 48” Built-in Refrigerator Diagnostics (Second Generation):

Models: EF36LNBSS / EF36RNBSS / IF36LNBOL / IF36RNBOL / EF42NBSS / EF42DBSS / IF42NBOL / IF42DBOL / EF48NBSS /

EF48DBSS / IF48NBOL / IF48DBOL

Service Diagnostic Mode Chart

Water Filter Input (WFI) Test

To confirm that the water valves are being monitored by the WFI control, follow the procedures listed:

Testing the Dispenser Valve Input Testing the Ice maker Valve Input

1. Open the refrigerator door.

2. Depress the refrigerator light switch.

1. Open the refrigerator door.

2. Depress the refrigerator light switch.

3. Place a container under the water spout.

4. Activate the water dispenser.

3. Activate the ice maker and wait for a water fill.

4. Read the WFI display during the fill. “99” indicates a normal input.

PG: 33

Dacor WineStation Screen Functions

Model: DYWS4

The WineStation is designed to provide a wide range of operating functions.

Below you will find an in depth review of each LCD Screen and its function:

1. Unlocking your WineStation a. Open the front door. b. Lift the spout cover.

4 Position

Switch Board c. Underneath the spout cover you will find a switch board. Move the switch down one notch to access the service menu. d. Select “Bottle Service.” e. Select “Exit.” f. Next, move the switch back to the up position. g. Close the spout cover. h. Close the front door. i. Your WineStation is now unlocked.

2. WineStation Bottle Service Set Up Screen, Default Settings: a. To begin utilizing the functionality of your WineStation, first open the front door, lift the spout cover and move the switch down one notch to get to the main menu.

Note: When you are done using the service menu, you will need to move the switch back to the up function of the system.

b. To begin preparing your bottles for insertion in the WineStation, select “Bottle Service.” c. From the Bottle Service Screen, you will select “Wine Display” so that you may set up the display to showcase Wine Type, Wine Year, and Wine Varietal. d. Now you can select Wine Type (Red or White). e. Select the varietal by utilizing the side buttons to scroll through the list, then press “Exit”.

The WineStation has over 100 wine varietal options including unique offerings, found using the Other button.

See Appendix for complete listing. f. Next you will select Set Year, utilizing the side buttons to set year.

PG: 34

Dacor WineStation Screen Functions

Continued…

Model: DYWS4

3. Setting Pour Volumes. a. Next you will select “Set VOL”. b. Volume sizes will appear on the Volume Size selection screen.

Using the buttons on the right, you can set the desired pour volume in ½ ounce increments, as shown right:

4. Setting the Temperature a. To set the desired temperature, select “WineStation Service” from the default menu screen and then select “More.” b. Next, select “Set Temp”. c. Now set desired temperature by using the + and – buttons.

Select “Exit” when finished to save settings.

Note: You may use Celsius or Fahrenheit. d. You may also turn off cooling by selecting cooling mode, as shown in the screen right:

5. Adjust Bottle Light a. To adjust the Bottle Light, return to

“WineStation Service” menu and select “More” twice. b. Select “Adjust Bright”. c. You may adjust Brightness or

Contrast, using the + and – buttons.

6. Pour Detection

The WineStation can also detect if there is a fault in the pouring capabilities of each bottle position. a. Pour Detection can be turned off from the “Bottle Service” menu. i. Selecting this option will turn off the WineStation’s ability to detect the empty bottle condition. ii. Pouring will continue to be accurate if this option is selected.

7. Diagnostic Information

The “Diag.” screen menu can be selected from the “WineStation Service” screen to provide detailed diagnostic information about the WineStation.

This information may be helpful to determine version levels or for servicing purposes. a. To get to the diagnostic screen, select “More” and then select “Diag Screen”.

Dacor Technical Assistance: 800-353-2267

PG: 35

Dacor Coffee System Programming:

Models: CM24T and CM24P

Accessing the Main Programming Menu:

Remove the drip tray. Unlock the front panel door. When the door is open, the buttons on the front of the unit will not make drinks when pushed. “Machine Off - Front Panel Open” should appear on the display. If it does not, find the white button on the back of the front panel door. Push and release the white button. Check to make sure “Machine Off - Front Panel Open” appears on the display. With the front panel door open, push and release the far left button on the front panel (the one with “MENU” above it). Nothing will appear to happen. Pull out on the white button on the back of the front panel door. You will hear the normal sound of the tamping motor cycling. In about 5 seconds “Cumulative” will appear on the display. The unit is now in the manual-programming mode. You will use the four buttons on the left of the front panel to program it. The drink functions on the buttons are ignored during the programming process.

Feature Menus

Cumulative Total:

The cumulative total feature allows you to view the total number of drinks made by your coffee system and the number of individual drinks made. It is not programmable. To view the number of drinks made:

1. With “Cumulative Total” displayed on the main programming menu, push the MENU button.

2.To check each drink individually, repeatedly push the MENU button.

3. Push SET to exit.

4. Push the DOWN button repeatedly to select a feature to change or close the front panel door to exit the main programming menu.

Changing the Button Assignment:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Product Name” appears on the display. “Product Name” changes the type of drink programmed for each button.

2. Push the MENU button.

3. Repeatedly push the MENU button to see the drink assigned to each button. Each drink type shown has a number in the upper right of the display. The number represents the button programmed for this drink. 1 is the button on the far left, 2 is the next button to the right and so on. Stop on the button number you want to change.

4. To select a drink for the button number shown, scroll using the UP or DOWN buttons until you find the desired beverage.

5. Push the SET button to change to the new drink type.

6. Push the UP or DOWN repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Changing the Amount of Water:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Water Volume” appears on the display.

2. Push the MENU button.

3. Repeatedly push the MENU button to see the amount of water (in CCs) dispensed with each drink. Stop on the drink for which you want to change the amount of water dispensed.

4. To adjust the water amount, push the UP or DOWN buttons.

5. Push the SET button to change to the new water amount.

6. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Changing the Grind Time:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Grind Time” appears on the display.

2. Push the MENU button.

3. Repeatedly push the MENU button to see the grind time for each drink. Stop on the drink for which you want to change the grind time.

4. To adjust the grind time, push the UP or DOWN buttons.

5. Push the SET button to change to the new grind time.

6. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Changing the Milk Time:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Milk Time” appears on the display.

2. Push the MENU button.

3. Repeatedly push the MENU button to see the milk time for each drink. Stop on the drink for which you want to change the milk time.

4. To adjust the milk time, push the UP or DOWN buttons.

5. Push the SET button to change to the new milk time.

6. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

PG: 36

Turning Pre-brew On and Off:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Pre-brew” appears on the display.

2. Push the MENU button.

3. Repeatedly push the MENU button to see the pre-brew status for each drink. Stop on the drink for which you want to turn pre-brew on or off.

4. Push the UP or DOWN buttons to select “Yes” or “No”.

5. Push the SET button to make the change.

6. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Turning Tamping On and Off:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Tamping” appears on the display.

2. Push the MENU button.

3. Repeatedly push the MENU button to see the tamping status for each drink. Stop on the drink for which you want to turn tamping on or off.

4. Push the UP or DOWN buttons to select “Yes” or “No”.

5. Push the SET button to make the change.

6. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Changing the Used Coffee Ground Bin Meter:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Grounds Number” appears on the display.

2. Push the MENU button.

3.To adjust the number of grounds detected in the bin before the “Drawer Full” message appears on the display, push the UP or DOWN buttons. The default setting is 20.

4. Push the SET button to change to the new ground number.

5. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Milk Cleaning Warning Time:

Pre-set at the factory to 2 hours. Do not change.

Routine Cleaning Warning Time:

Pre-set at the factory to 50 cycles. Do not change.

Group Setting:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Group” appears on the display.

2. Push the MENU button.

3.If the group number is not set to 2.0, push the UP or DOWN buttons until the display shows a group setting of 2.0. The coffee system will not work properly set to any other value.

4. Push the SET button.

5. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Changing the Grinder Setting Warning:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Grinder Setting” appears on the display.

2. Push the MENU button.

3. To adjust the amount of drinks prepared before the “Grinder Setting” message appears on the display, push the UP or DOWN buttons. The default is 250.

4. Push the SET button to change the grinder setting warning.

5. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Changing the Coffee Temperature:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Coffee Temperature” appears on the display.

2. Push the MENU button.

3. To adjust the coffee temperature, push the UP or DOWN buttons. The default is 98°C.

4. Push the SET button to change the temperature setting.

5. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Changing the Steam Temperature:

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Steam Temperature” appears on the display.

2. Push the MENU button.

3. To adjust the coffee temperature, push the UP or DOWN buttons. The default is 125°C.

4. Push the SET button to change the temperature setting.

5. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

Changing the Water Filter Warning:

If you install a water filter to lower the hardness of the water supplied to your coffee system, you can program the system to warn you when you need to change the filter cartridge. Check the manufacturer instructions for the filter cartridge capacity. Enter the filter capacity into the coffee system in liters (3.8 liters = 1 gallon).

1. With the main programming menu accessed, push the UP or DOWN button repeatedly until “Water Filter” appears on the display.

2. Push the MENU button.

3. To adjust the number of liters used by the coffee system before the “Water Filter” message appears on the display, push the UP or DOWN buttons.

4. Push the SET button to accept the clean warning number entered.

5. Push the UP or DOWN button repeatedly to select another feature to change or close the front panel door to exit the main programming menu.

PG: 37

advertisement