Comtech EF Data SNM 1002 Modem Operation and Maintenance Manual
Below you will find brief information for Modem SNM 1002. The SNM-1002 LinkSync™ modem is a high performance, digital modem designed to provide LinkSync™ functionality for Comtech EF Data's Bandwidth-on-demand (BOD) Multimedia Integrated Digital Access System (MIDAS). The modem contains built-in scramblers/descramblers, differential encoder/decoder, TX and RX frequency synthesizers, multi-rate FEC convolutional Viterbi Decoder, and more.
Advertisement
Advertisement
SNM-1002 LinkSync Modem Operation and Maintenance Manual Part Number MN/SNM1002.OM Revision 2 SNM-1002 LinkSync™ Modem Operation and Maintenance Manual Comtech EFData is an ISO 9001 Registered Company. Part Number MN/SNM1002.OM Revision 2 May 15, 2002 Copyright © Comtech EFData, 2000. All rights reserved. Printed in the USA. Comtech EFData, 2114 West 7th Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161. SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM Network Customer Support The Network Customer Support Plan identifies the steps to be followed in resolving the Customer’s concern. The resolution efforts will follow these levels of contact: • • • Level One Contact – Factory Authorized Service Center. Level Two Contact – Comtech EF Data Customer Support. Level Three Contact – Network Test and Field Support Procedural Steps Step 1 Procedure The Customer raises a concern with the Level One Contact. 2 The Level One Contact will perform Hardware repairs and Network Operations troubleshooting in accordance with the Comtech EF Data Service Center agreement. 3 If the Level One Contact is unable to resolve the concern, then the Level One Contact will inform the Level Two Contact of the concern in accordance with the instructions found within the attached Comtech EF Data Customer Support Department’s document. 4 The Level Two Contact will enter the concern into the Comtech EF Data database and determine whether the concern is a Hardware concern or a Network Operations concern 5 The Level Two Contact will interface with the Level One Contact and provide the appropriate hardware support and enter all correspondence into the Comtech EF Data database. 6 If the Level Two Contact determines that the concern is a Network Operations concern, then the Level Two Contact will inform the Level Three Contact. 7 The Level Three Contact will interface with the Level One Contact and provide the appropriate support and enter all correspondence into the Comtech EF Data database. 8 If the Level Three Contact determines that there is a Hardware failure then the Level Three Contact will inform the Level Two Contact. Go to Step 5. ii SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.om Network Customer Support Plan Customer Yes Midas Network is functioning properly? *Note: If equipment was purchased directly from Comtech EFData (not through a Factory Authorized Service Center), then CEFD Customer Support will be the initial point of contact. No Level One Contact is notified Authorized Factory Service Center Yes Resolved by Hardware repair or Network Operations troubleshooting? No Level Two Contact is notified CEFD Customer Support CEFD Customer Support provides HW support Hardware or Network Operations issue? Hardware Hardware Network Operations Level Three Contact is notified CEFD Network Test and Field Support CEFD Network Test and Field Support provides Network Operations support Hardware or Network Operations issue? iii SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM See the Comtech EF Data website at http://www.comtechefdata.com for contact information for a Factory Authorized Service Center. Contact the Factory Authorized Service Center for: • Product support • Information on upgrading or returning a product Contact the Comtech EF Data Customer Support Department for: • Product support or training • Information on upgrading or returning a product A Customer Support representative may be reached at: Comtech EF Data Attention: Customer Support Department 2114 West 7th Street Tempe, Arizona 85281 USA 480.333.2200 (Main Comtech EF Data Number) 480.333.4357 (Customer Support Desk) 480.333.2500 FAX or, E-Mail can be sent to the Systems Support Engineering at: [email protected] To return a Comtech EF Data product (in-warranty and out-of-warranty) for repair or replacement: 1. Request a Return Material Authorization (RMA) number from the Comtech EF Data Customer Support Department. 2. Be prepared to supply the Customer Support representative with the model number, serial number, and a description of the problem. 3. To ensure that the product is not damaged during shipping, pack the product in its original shipping carton/packaging. 4. Ship the product back to Comtech EF Data. (Shipping charges should be prepaid.) iv SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.om Contact the Comtech EF Data Network Test and Field Support for: • • • System level Network Operations support Information on upgrading Network Operation software Reporting comments or suggestions concerning manuals A Network Test and Field Support representative may be reached at: Comtech EF Data Attention: Network Test and Field Support 2114 West 7th Street Tempe, Arizona 85281 USA 480.333.2200 (Main Comtech EF Data Number) 480.333.3693 (Network Test and Field Support) 480.333.2161 (FAX) or, E-Mail can be sent to the Network Test and Field Support Department at: mailto:[email protected] Contact us via the web at www.comtechefdata.com. v SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM This page is intentionally left blank. vi Table of Contents CHAPTER 1. INTRODUCTION ...................................................................................................... 1–1 1.1 Overview ...................................................................................................................................... 1–1 1.2 Mode of Operation ...................................................................................................................... 1–2 1.3 Options ......................................................................................................................................... 1–5 1.4 Specifications ............................................................................................................................... 1–6 1.4.1 1.4.2 Summary Specifications........................................................................................................................ 1–6 Environmental and Physical.................................................................................................................. 1–8 1.5 Bit Error Rate Performance ...................................................................................................... 1–8 1.6 Typical Spectral Occupancy .................................................................................................... 1–10 1.7 Dimensional Envelope .............................................................................................................. 1–11 CHAPTER 2. INSTALLATION ................................................................................... 2–1 2.1 Unpacking.................................................................................................................................... 2–1 2.2 Installation ................................................................................................................................... 2–2 2.2.1 2.2.2 2.3 2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.3.6 2.3.7 2.3.8 Typical Single-Thread Cable Installation.............................................................................................. 2–4 Typical Redundant Cable Installation ................................................................................................... 2–5 Rear Panel Connections.............................................................................................................. 2–7 Remote Connector and Pinouts (J6)...................................................................................................... Data I/O Interface Connector (J8) ......................................................................................................... RF Output Connector (CP1).................................................................................................................. RF Input Connector (CP2) .................................................................................................................... External Reference (CP3)...................................................................................................................... AC Power Connector ............................................................................................................................ DC Power - Optional............................................................................................................................. Ground Connector (GND)..................................................................................................................... vii 2–8 2–8 2–8 2–8 2–9 2–9 2–9 2–9 SNM-1002 LinkSync™ Modem Preface CHAPTER 3. 3.1 3.1.1 3.1.2 Revision 2 MN/SNM1002.OM OPERATION ........................................................................................ 3–1 Front Panel .................................................................................................................................. 3–1 LED Indicators ...................................................................................................................................... 3–2 Front Panel Keypad............................................................................................................................... 3–3 3.2 Menu System ............................................................................................................................... 3–4 3.3 Front Panel Menu ....................................................................................................................... 3–5 3.4 OPENING SCREEN................................................................................................................... 3–6 3.4.1 FUNCTION SELECT:CONFIGURATION ......................................................................................... 3–6 3.4.1.1 CONFIGURATION:MODULATOR..............................................................................................3–7 3.4.1.2 CONFIGURATION:DEMODULATOR ......................................................................................3–11 3.4.1.3 CONFIGURATION:INTERFACE ...............................................................................................3–15 3.4.1.4 CONFIGURATION:SAVE...........................................................................................................3–20 3.4.1.5 CONFIGURATION:RECALL......................................................................................................3–20 3.4.2 FUNCTION SELECT:MONITOR ....................................................................................................... 3–21 3.4.2.1 MONITOR:RAW BER .................................................................................................................3–21 3.4.2.2 MONITOR:CORRECTED BER...................................................................................................3–21 3.4.2.3 MONITOR:EB/NO .......................................................................................................................3–21 3.4.2.4 MONITOR:RECEIVE SIGNAL...................................................................................................3–22 3.4.2.5 MONITOR:SWEEP FREQUENCY .............................................................................................3–22 3.4.2.6 MONITOR:BUFFER FILL...........................................................................................................3–22 3.4.3 FUNCTION SELECT:FAULTS/ALARMS ......................................................................................... 3–23 3.4.3.1 FAULTS AND ALARMS:MODULATOR ..................................................................................3–24 3.4.3.2 FAULTS AND ALARMS:DEMODULATOR.............................................................................3–24 3.4.3.3 FAULTS AND ALARMS:TX INTERFACE ...............................................................................3–25 3.4.3.4 FAULTS AND ALARMS:RX INTERFACE ...............................................................................3–26 3.4.3.5 FAULTS AND ALARMS:COMMON .........................................................................................3–27 3.4.4 FUNCTION SELECT:STORED FLTS/ALMS .................................................................................... 3–28 3.4.4.1 STORED FLTS/ALMS:MODULATOR ......................................................................................3–29 3.4.4.2 STORED FLTS/ALMS:DEMODULATOR .................................................................................3–29 3.4.4.3 STORED FLTS/ALMS:TX INTERFACE....................................................................................3–30 3.4.4.4 STORED FLTS/ALMS:RX INTERFACE....................................................................................3–31 3.4.4.5 STORED FLTS/ALMS:COMMON..............................................................................................3–32 3.4.4.6 STORED FLTS/ALMS:CLEAR...................................................................................................3–32 3.4.5 FUNCTION SELECT:UTILITY .......................................................................................................... 3–33 3.4.5.1 UTILITY:MODULATOR.............................................................................................................3–34 3.4.5.2 UTILITY:DEMODULATOR .......................................................................................................3–37 3.4.5.3 UTILITY:INTERFACE ................................................................................................................3–39 3.4.5.4 UTILITY:SYSTEM ......................................................................................................................3–43 3.4.5.5 UTILITY:MODEM TYPE............................................................................................................3–48 3.4.5.6 UTILITY:FACTORY SETUP (NOT APPLICABLE)..................................................................3–53 viii SNM-1002 LinkSync™ Modem Preface CHAPTER 4. Revision 2 MN/SNM1002.OM THEORY OF OPERATION ................................................................. 4–1 4.1 Monitor and Control (M&C) ..................................................................................................... 4–1 4.2 Modulator .................................................................................................................................... 4–3 4.2.1 4.2.2 4.2.3 4.3 4.3.1 4.3.2 Modulator Specifications ...................................................................................................................... 4–5 Theory of Operation.............................................................................................................................. 4–6 Theory of Modulation Types................................................................................................................. 4–7 Demodulator................................................................................................................................ 4–9 Demodulator Specifications .................................................................................................................. 4–10 Theory of Operation.............................................................................................................................. 4–11 CHAPTER 5. 5.1 5.1.1 5.1.2 5.1.3 5.2 5.2.1 5.2.2 5.2.3 MAINTENANCE.................................................................................. 5–1 System Checkout......................................................................................................................... 5–1 Interface Checkout ................................................................................................................................ 5–2 Modulator Checkout.............................................................................................................................. 5–3 Demodulator Checkout ......................................................................................................................... 5–6 Fault Isolation.............................................................................................................................. 5–8 System Faults/Alarms ........................................................................................................................... 5–8 Faults/Alarms Display........................................................................................................................... 5–12 Faults/Alarms Analysis ......................................................................................................................... 5–12 APPENDIX A. REMOTE CONTROL OPERATION..................................................A–1 APPENDIX B. REDUNDANT WIRING SCHEMATIC...............................................B–1 ix SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM Figures Figure 1-1. Figure 1-2. Figure 1-3. Figure 1-4. Figure 1-5. Figure 1-6. Figure 1-7. Figure 1-8. Figure 2-1. Figure 2-2. Figure 2-3. Figure 2-2. Figure 3-1. Figure 3-2. Figure 3-3. Figure 3-4. Figure 4-1. Figure 4-2. Figure 4-3. Figure 5-1. Figure 5-2. Figure 5-3. Figure 5-4. SNM-1002 .............................................................................................................................................1–1 Typical NMS Configuration ..................................................................................................................1–2 Typical Redundancy for the Network and LinkSync Modems ..............................................................1–3 Modular Design .....................................................................................................................................1–3 Block Diagram .......................................................................................................................................1–5 Viterbi BER Performance Curves..........................................................................................................1–9 Typical Spectral Occupancy ................................................................................................................1–10 SNM-1002 Dimensional Envelope ......................................................................................................1–11 Installation of the Mounting Bracket .....................................................................................................2–3 Typical Single-Thread Installation.........................................................................................................2–4 Typical Redundant Wiring Schmetic .....................................................................................................2–6 View of Rear Panel ................................................................................................................................2–7 Front Panel View ...................................................................................................................................3–1 Keypad ...................................................................................................................................................3–3 Main Menu.............................................................................................................................................3–5 Baseband Loopback .............................................................................................................................3–18 M&C Block Diagram.............................................................................................................................4–2 Modulator Block Diagram .....................................................................................................................4–4 Demodulator Block Diagram .................................................................................................................4–9 Fault Isolation Test Setup ......................................................................................................................5–2 Typical Output Spectrum (with Noise) ..................................................................................................5–5 Typical Output Spectrum (without Noise) .............................................................................................5–5 Typical Eye Constellations ....................................................................................................................5–7 Tables Table 1-1. Table 1-2. Table 2-1. Table 2-2. Table 3-1. Table 4-1. Table 4-2. Table 5-1. Table 5-2. Summary Specifications..........................................................................................................................1–6 Environmental and Physical....................................................................................................................1–8 Rear Panel Connectors ............................................................................................................................2–4 Remote Connector and Pinouts (J6) ........................................................................................................2–5 LED Indicators ........................................................................................................................................3–2 Modulator Specifications ........................................................................................................................4–5 Demodulator Specification....................................................................................................................4–10 Conversion to S/N and Eb/N0 Chart.........................................................................................................5–4 SNM-1002 Fault Tree .............................................................................................................................5–9 x SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM About this Manual This manual provides installation and operation information for the Comtech EF Data SNM-1002 LinkSync™ Modem. This is a technical document intended for earth station engineers, technicians, and operators responsible for the operation and maintenance of the SNM-1002 LinkSync™ Modem. Conventions and References Cautions and Warnings CAUTION CAUTION indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. CAUTION may also be used to indicate other unsafe practices or risks of property damage. WARNING indicates a potentially hazardous situation that, if not avoided, could result in death or serious injury. WARNING IMPORTANT indicates a statement that is associated with the task being performed. . IMPORTANT Metric Conversion Metric conversion information is located on the inside back cover of this manual. This information is provided to assist the operator in cross-referencing English to Metric conversions. Recommended Standard Designations Recommended Standard (RS) Designations have been superseded by the new designation of the Electronic Industries Association (EIA). References to the old designations are shown only when depicting actual text displayed on the screen of the unit (RS-232, RS485, etc.). All other references in the manual will be shown with the EIA designations (EIA-232, EIA-485, etc.) only. For more information, refer to the Department of Defense (DOD) MIL-STD-188-114A, “Electrical Characteristics of Digital Interface Circuits.” xi SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM Trademarks Products names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Reporting Comments or Suggestions Concerning this Manual Comments and suggestions regarding the content and design of this manual will be appreciated. To submit comments, please contact the Comtech EF Data Technical Publications department: [email protected] Electrical Safety The SNM-1002 LinkSync Modem has been shown to comply with the following safety standard: • EN 60950: Safety of Information Technology Equipment, including electrical business machines. The equipment is rated for operation over the range 85 to 264 volts AC. It has a maximum power consumption of 60 watts. Fuses The SNM-1002 LinkSync Modem is fitted with two fuses, one each for line and neutral connections. These are contained within the body of the IEC power connector, behind a small plastic flap. • For 230 volt AC operation, use T0.75A, 20mm fuses. • For 115 volt AC operation, use T1.25A fuses, 20mm fuses. For continued operator safety, always replace the fuses with the correct type and rating. IMPORTANT Environmental The SNM-1002 must not be operated in an environment where the unit is exposed to extremes of temperature outside the ambient range 0 to 50°C (32 to 122°F), precipitation, condensation, or humid atmospheres above 95% RH, altitudes (un-pressurised) greater than 2000 metres, excessive dust or vibration, flammable gases, corrosive or explosive atmospheres. Operation in vehicles or other transportable installations that are equipped to provide a stable environment is permitted. If such vehicles do not provide a stable environment, safety of the equipment to EN60950 may not be guaranteed. xii SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM Installation The installation and connection to the line supply must be made in compliance to local or national wiring codes and regulations. The SNM-1002 is designed for connection to a power system that has separate ground, line and neutral conductors. The equipment is not designed for connection to power system that has no direct connection to ground. The SNM-1002 is shipped with a line inlet cable suitable for use in the country of operation. If it is necessary to replace this cable, ensure the replacement has an equivalent specification. Examples of acceptable ratings for the cable include HAR, BASEC and HOXXX-X. Examples of acceptable connector ratings include VDE, NF-USE, UL, CSA, OVE, CEBEC, NEMKO, DEMKO, BS1636A, BSI, SETI, IMQ, KEMA-KEUR and SEV. International Symbols: Symbol Definition Symbol Definition ~ Alternating Current Protective Earth Fuse Chassis Ground Telecommunications Terminal Equipment Directive In accordance with the Telecommunications Terminal Equipment Directive 91/263/EEC, this equipment should not be directly connected to the Public Telecommunications Network. xiii SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM EMC (Electromagnetic Compatibility) In accordance with European Directive 89/336/EEC, the SNM-1001 Network Modem has been shown, by independent testing, to comply with the following standards: Emissions: EN 55022 Class B - Limits and methods of measurement of radio interference characteristics of Information Technology Equipment. (Also tested to FCC Part 15 Class B) Immunity: EN 50082 Part 1 - Generic immunity standard, Part 1: Domestic, commercial and light industrial environment. Additionally, the SNM-1001-has been shown to comply with the following standards: EN 61000-3-2 Harmonic Currents Emission EN 61000-3-3 Voltage Fluctuations and Flicker EN 61000-4-2 ESD Immunity EN 61000-4-4 EFT Burst Immunity EN 61000-4-5 Surge Immunity EN 61000-4-6 RF Conducted Immunity EN 61000-4-8 Power frequency Magnetic Field Immunity EN 61000-4-9 Pulse Magnetic Field Immunity EN 61000-4-11 Voltage Dips, Interruptions, and Variations Immunity EN 61000-4-13 Immunity to Harmonics In order that the Modem continues to comply with these standards, observe the following instructions: IMPORTANT • Connections to the transmit and receive IF ports (BNC female connectors) should be made using a good quality coaxial cable - for example RG58/U (50 Ω or RG59/U (75 Ω). • All 'D' type connectors attached to the rear panel must have back-shells that provide continuous metallic shielding. Cable with a continuous outer shield (either foil or braid, or both) must be used, and the shield must be bonded to the back-shell. • The equipment must be operated with its cover on at all times. If it becomes necessary to remove the cover, the user should ensure that the cover is correctly re-fitted before normal operation commences. xiv SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM Warranty Policy This Comtech EF Data product is warranted against defects in material and workmanship for a period of two years from the date of shipment. During the warranty period, Comtech EF Data will, at its option, repair or replace products that prove to be defective. For equipment under warranty, the customer is responsible for freight to Comtech EF Data and all related custom, taxes, tariffs, insurance, etc. Comtech EF Data is responsible for the freight charges only for return of the equipment from the factory to the customer. Comtech EF Data will return the equipment by the same method (i.e., Air, Express, Surface) as the equipment was sent to Comtech EF Data. Limitations of Warranty The foregoing warranty shall not apply to defects resulting from improper installation or maintenance, abuse, unauthorized modification, or operation outside of environmental specifications for the product, or, for damages that occur due to improper repackaging of equipment for return to Comtech EF Data. No other warranty is expressed or implied. Comtech EF Data specifically disclaims the implied warranties of merchantability and fitness for particular purpose. Exclusive Remedies The remedies provided herein are the buyer's sole and exclusive remedies. Comtech EF Data shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any other legal theory. Disclaimer Comtech EF Data has reviewed this manual thoroughly in order that it will be an easy-to-use guide to your equipment. All statements, technical information, and recommendations in this manual and in any guides or related documents are believed reliable, but the accuracy and completeness thereof are not guaranteed or warranted, and they are not intended to be, nor should they be understood to be, representations or warranties concerning the products described. Further, Comtech EF Data reserves the right to make changes in the specifications of the products described in this manual at any time without notice and without obligation to notify any person of such changes. If you have any questions regarding your equipment or the information in this manual, please contact the Comtech EF Data Network Customer Support Department. xv SNM-1002 LinkSync™ Modem Preface Revision 2 MN/SNM1002.OM This page is intentionally left blank. xvi Chapter 1. INTRODUCTION This chapter provides an overview of the SNM-1002 LinkSync Modem, referred to in this manual as “the modem” (Figure 1-1). Figure 1-1. SNM-1002 LinkSync Modem 1.1 Overview The SNM-1002 LinkSync™ modem is a high performance, digital modem designed to provide LinkSync™ functionality for Comtech EF Data's Bandwidth-on-demand (BOD) Multimedia Integrated Digital Access System (MIDAS). Features of the SNM-1002 include: • • • • • 19.2 kbit/s, QPSK, 1/2 rate continuous demodulator. 2.4 kbit/s to 4.375 mbit/s continuous modulator. 50/180 MHz operation. Extensive online monitoring. Built in Self-test. 1–1 SNM-1002 LinkSync™ Modem Introduction 1.2 Revision 2 MN/SNM1002.OM Mode of Operation The SNM-1002 is an integral component of the MIDAS Network Management System (NMS), providing the LinkSync™ monitor and control communication between the NMS and the MIDAS network. LinkSync™ provides three key functions for the MIDAS network. • • • Automatic Frequency Control (AFC) for all modems within the network. Power Management for all active traffic circuits within the network. Circuit Disruption capability which allows the NMS to terminate circuits between any two internal traffic nodes (SNM-1010/1010L)in the network. The SNM-1002 performs a critical roll for each of these three LinkSync™ capabilities under the direct control of the MIDAS NMS. Refer to Chapter 4. Theory of Operation. NETWORK CONTROL MODEM (SNM-1001) EIA-422 EIA-232 ETHERNET EIA-232 E NTE R C LEA R S N M - 1 0 0 1 N e t w o r k A S S D A T E C o n T RANS MI T - 1AL 2 T t r o F 0 AU 0 RECEI V E L R LM S I T E L TT S l M o d e m TR ANSMI T P O WER O N RECE I VE T RANS MITTE R ON IF (50-180 MHz) ENT ER ECOM MON R M CA I RRIE N R DET A ECTL CLE AR S TO RED T EST MO DE T M OPERATOR WORKSTATION NMS CONTROLLER LinkSync MODEM (SNM-1002) OPTIONAL PRINTER (USER SUPPLIED) Figure 1-2. Typical NMS Configuration 1–2 RFT SNM-1002 LinkSync™ Modem Introduction Revision 2 MN/SNM1002.OM Figure 1-3. Typical LinkSync Redundancy 1.2.1 Description The modem contains: Built-in scramblers/descramblers Differential encoder/decoder TX and RX frequency synthesizers Multi-rate FEC convolutional Viterbi Decoder The modem is a complete, self-contained unit in a standard, one-rack unit (1 RU), 19inch (48 cm), rack-mountable enclosure weighing approximately 9 lbs. (4 kg). The unit was constructed using modular design (Figure 1-4), and consists of from two to five Printed Circuit Boards (PCBs), depending on the configuration. The modem consists of two, major, replaceable assemblies as follows: • • Rear panel, main PCB, and power supply Upper and lower enclosures (chassis) and the front panel 1–3 SNM-1002 LinkSync™ Modem Introduction Revision 2 MN/SNM1002.OM Figure 1-4. Modular Design The front panel of the modem contains all Monitor and Control (M&C) function indicators used for operating the modem. The modem can be operated remotely via the M&C connection on the rear panel. Refer to Chapter 2 for connector information and Appendix A for remote control operation information. 1–4 SNM-1002 LinkSync™ Modem Introduction Revision 2 MN/SNM1002.OM Refer to Figure 1-5 for a system block diagram. Figure 1-5. Block Diagram 1.3 Options Option Primary Input Power: 90-264 VAC -48 VDC IF Impedance : 75Ω 50Ω 1–5 Remarks KT/8000-3 KT/8000-4 PL/6093-1 PL/6093-3 SNM-1002 LinkSync™ Modem Introduction Revision 2 MN/SNM1002.OM 1.4 Specifications 1.4.1 Summary Specifications Table 1-1 lists a summary of the specifications. Table 1-1. Summary Specifications Parameter Operating Frequency Range Modulation Type Operating Channel Spacing Digital Interface Digital Data Rate Scrambling/Descrambling Forward Error Correction Filter Mask Types Modulator Output Power Output Spurious Output Impedance Output Return Loss Data Clock Source Demodulator Input Power: Desired Carrier Adjacent Carriers Maximum Total Input Impedance Input Return Loss Carrier Acquisition Range Clock Acquisition Range AGC Output Specification 50 to 180 MHz, in 1 Hz steps QPSK BPSK Less than 0.5 dB degradation operating with 2 adjacent-like channels, each 10 dB higher at 1.3 times the symbol rate. EIA-422/449 on 37-pin D QPSK, R=1/2, 2.4 kbps to 4.375 Mbps CCIT INTELSAT V.35 Viterbi, K=7, Rate 1/2, 3/4, 7/8 Closed net (Comtech EF Data) -5 to –30 dBm, adjustable in 0.1 dB steps < -55 dBc, 0 to 500 MHz 75Ω (Optional: 50Ω) 20 dB Internal , ± 1 x 10-5 stability -30 to –55 dBm +30 dBc total power within 10 MHz from desired carrier +40 dBc in-band (0 to 500 MHz) -5 dBm 75Ω (Optional: 50Ω) 20 dB ± 35 kHz maximum ± 100 PPM 0 to 10V at 10 mA maximum Default Levels: 0V for –60 dBm 10V for –25 dBm Levels can be programmed in 0.5V increments. 1–6 SNM-1002 LinkSync™ Modem Introduction Revision 2 MN/SNM1002.OM Table 1-1. Summary Specifications (Continued) Remote Control Specification Signal Interface Baud Rate Signals Controlled/Monitored Signals Monitored Configuration Retention Addressing Diagnostic Diagnostic Features EIA-232 19.2 kbps Acquisition Sweep Parameters Baseband Loopback Buffer Clock TX/RX/INT Buffer Size Code and decode Rate Data Rate Select Descrambler On/Off Descrambler Type Differential Encoding and Decoding IF Loopback Interface Loopback MOD/DEMOD Spectrum Normal/Invert Rev Emulation Current/Function RF Loopback RX Clock Normal/Invert RX Frequency Scrambler On/Off Scrambler Type Self Test Transmitter On/Off TX Frequency TX Power TX/RX Filter Mask Corrected BER Fault Status Power Supply Voltage Raw Error Rate RX Carrier Detect RX Eb/No RX Signal Level Stored Fault Status Will maintain current configuration for at least 1 year without power. Programmable from 1 to 255 possibilities Address 0 is reserved for global addressing. BER Monitoring Buffer Fill Status Monitoring Fault Monitoring (include current and stored faults) IF Loopback Input IF Power Monitoring Remote Control via Serial Port RF Loopback 1–7 SNM-1002 LinkSync™ Modem Introduction 1.4.2 Revision 2 MN/SNM1002.OM Environmental and Physical Table 1-2. Environmental and Physical Parameter Size Power Operating Temperature Storage Temperature Humidity Mounting Operational Shock Survivability Shock and Vibration Weight Shipping: Weight Size 1.5 Specifications 1 rack unit (1RU) 1.75" H x 19.0" W x 14" D (4.4 H x 48 W x 36 D cm) Prime power 90 to 264 VAC, 47 to 63 Hz, 40W maximum, fused at 2A Optional: 38 to 64 VDC 0 to 50°C (32 to 122° F) -55 to +70° C (-67 to 158° F) 0 to 95% non-condensing Standard 19-inch (48.3 cm) rack mounts Note: Front and rear accepts standard rack mount slides When any one corner of the modem is dropped from 1 cm onto a hard surface, the modem will not take any errors or faults MIL-STD-167-1 MIL-STD-810D Method 514.4, Procedure 8, 1 hour/axis 9 lbs. Maximum (4 kg Maximum) 15 lbs. (7 kg) 20 x 21 x 9 inch (51 x 53 x 23 cm) Bit Error Rate Performance The following specifications for the Eb/N0 required to achieve 10-3 to 10-8 BER for different coding configurations. All values are for operating in QPSK mode. Without coding, the modem provides QPSK operation within 0.8 dB of theoretical for BER in the range 10-1 to 10-6. Performance measurements were recorded with transmit and receive IF connected back-to-back through an additive white Gaussian noise channel. Refer to Figure 1-6 for the performance BER curves. BER 10-3 10-4 10-5 10-6 10-7 10-8 Eb/N0 (dB) Specification 1/2 Rate 3/4 Rate 7/8 Rate 4.2 5.2 6.4 4.8 6.0 7.2 5.5 6.7 7.9 6.1 7.5 8.6 6.7 8.2 9.2 7.2 8.8 9.9 1–8 SNM-1002 LinkSync™ Modem Introduction 1.5.1 Revision 2 MN/SNM1002.OM BER Threshold The modem will have a programmable BER threshold function. This will allow the operator to set the threshold from 1.0 E-3 to 1.0 E-8. 10-2 10-3 10-4 10-5 10-6 BER 10-7 10-8 1/2 Rate 3/4 Rate 7/8 Rate 10-9 SPECIFICATIONS 10-10 3.0 4.0 5.0 6.0 7.0 8.0 9.0 Eb/N0 (dB) Figure 1-6. Viterbi BER Performance Curves 1–9 10.0 11.0 SNM-1002 LinkSync™ Modem Introduction 1.6 Revision 2 MN/SNM1002.OM Typical Spectral Occupancy Figure 1-7. Typical Spectral Occupancy 1–10 SNM-1002 LinkSync™ Modem Introduction 1.7 Revision 2 MN/SNM1002.OM Dimensional Envelope Note: All dimensions are in English units (centermeters are in parenthesis). Figure 1-8. SNM-1002 Dimensional Envelope 1–11 SNM-1002 LinkSync™ Modem Introduction Revision 2 MN/SNM1002.OM This page is intentionally left blank. 1–12 Chapter 2. INSTALLATION This chapter provides unpacking and installation instructions, and a description of external connections information. CAUTION 2.1 The equipment contains parts and assemblies sensitive to damage by Electrostatic Discharge (ESD). Use ESD precautionary procedures when touching, removing, or inserting PCBs. Unpacking The modem and manual are packaged in pre-formed, reusable, cardboard cartons containing foam spacing for maximum shipping protection. Do not use any cutting tool that will extend more than 1 inch into the container. This can cause damage to the modem. CAUTION Unpack the modem as follows: 1. 2. 3. 4. 5. 6. 7. Cut the tape at the top of the carton indicated by OPEN THIS END. Remove the cardboard/foam space covering the modem. Remove the modem, manual, and power cord from the carton. Save the packing material for storage or reshipment purposes. Inspect the equipment for any possible damage incurred during shipment. Check the equipment against the packing list to ensure the shipment is correct. Refer to Section 2.2 for installation instructions. 2–1 SNM-1002 LinkSync Modem Installation 2.2 Revision 2 MN/SNM1002.OM Installation The modem arrives fully assembled from the factory. After unpacking the modem, install the modem as follows: 1. If required, install the mounting bracket in equipment rack (Figure 2-1). Install and tighten the bracket bolts. 2. Loosen the screw with flat washer located on the left side of modem chassis. Mount the modem chassis into the equipment rack and slide the screw with flat washer through the slot of the mounting bracket. Tighten the screw sufficiently to allow the modem chassis to slide in the bracket. 3. Connect the cables to the proper locations on the rear panel. Refer to Section 2.3 for connector pinouts, placement, and function. 4. Connect the primary power cable to the power source. Before turning on the power switch, become familiar with the front panel operation in Chapter 3. 5. If problems exist with the installation, refer to Chapter 5 for troubleshooting information. 2–2 SNM-1002 LinkSync Modem Installation Revision 2 MN/SNM1002.OM Figure 2-1. Installation of the Mounting Bracket 2–3 SNM-1002 LinkSync Modem Installation 2.2.1 Revision 2 MN/SNM1002.OM Typical Single-Thread Cable Installation Note: Cables may be procured from Comtech EF Data by contacting Comtech EF Data Network Customer Support department for information. 1. Connect supplied Y-Cable (Figure 2-2) as follows: a. Connect the supplied-cable base connector to the FASTCOM card. b. Connect supplied-cable Port 1 connector to the Comtech EF Data supplied EIA-422 cable from SNM-1001 Modem. c. Cable Port 2 connector is not connected. 2. Connect 9-pin EIA-232 cable from Controller Server COM 1 port to SNM-1001 Remote port (J6). a. If non-redundant SNM-1001, the following remote settings are required: • EIA-232 • 19.2 Baud rate • 8N1 3. Connect 9-pin EIA-232 cable from Controller Server COM 2 port to SNM-1002 Remote port (J6). 4. Connect 25-pin pre-programmed dongle (security key) to Controller Server 25-pin I/O port. Figure 2-2. Typical Single-Thread Installation 2–4 SNM-1002 LinkSync Modem Installation Item No. 1 2 3 4 Cable Description Comtech EF Data Supplied CA/5684 EIA-232 EIA-232 From FASTCOM Card CA/5684 To Supplied Y-Cable MIDAS Controller COM 2 MIDAS Controller COM 1 Port 1 of the SNM-1001 SNM-1002 Remote port (J6) SNM-1001Remote port (J6) Redundant LinkSync (Network Control) Modem Installation Network Control Modem A typical redundant wiring schematic is included to assist the user in establishing a redundant configuration. The following table can assist the user in cable selection and location. One or both of the 1:1 redundant configurations can be installed in a MIDAS System. Figure 2-3 shows both Network Control Modem and LinkSync Modem Redundancy. Item No. 1 2 3 4 5 6 7 8 9 10 11 LinkSync Modem 2.2.2 Revision 2 MN/SNM1002.OM 12 13 14 15 16 17 18 19 20 21 Cable Description CA/5684 EIA-422 37-pin EIA-422 37-pin BNC BNC BNC BNC BNC BNC EIA-232 9-pin Ribbon Cable EIA-232 EIA-422 37-pin EIA-422 37-pin EIA-232 9-pin Ribbon Cable BNC BNC BNC BNC BNC BNC EIA-232 2–5 From MIDAS Controller SMS-301 (J2) SMS-301 (J3) SMS-301 (J4) (TX-IF) SMS-301 (J8) (RX-IF) SMS-301 (J9) A SMS-301 (J6) B SMS-301 (J7) B SMS-301 (J5) A SMS-301 (J13) Modem COM SMS-301 (J10) Remote Control SMS-301 (J2) SMS-301 (J3) SMS-301 (J13) Modem COM SMS-301 (J9) A SMS-301 (J8) RX-IF SMS-301 (J4) TX-IF SMS-301 (J5) A SMS-301 (J7) B SMS-301 (J6) B SMS-301 (J10) Remote Control To SMS-301 J1 COM SNM-1001(A) (J8) SNM-1001 (B) (J8) Combiner Combiner SNM-1001(A) CP2 TX/IF SNM-1001(B) CP1 TX/IF SNM-1001(B) CP2 RX/IF SNM-1001(A) CP1 TX/IF SNM-1001(A) (J6) Remote SNM-1001(B) (J6) Remote MIDAS Controller COM1 SNM-1002 (A) Data I/O SNM-1002 (B) Data I/O SNM-1002(A) (J6) Remote SNM-1002(B) (J6) Remote SNM-1002 A) CP2 RX-IF Combiner Combiner SNM-1002(A) CP1 TX-IF SNM-1002(B) CP2 RX-IF SNM-1002(B) CP1 TX-IF MIDAS Controller COM2 SNM-1002 LinkSync Modem Installation Revision 2 MN/SNM1002.OM Figure 2-3. Typical Redundant Wiring Schematic 2–6 SNM-1002 LinkSync Modem Installation 2.3 Revision 2 MN/SNM1002.OM Rear Panel Connections The rear panel connectors provide all necessary external connections between the modem and other equipment. Table 0-1 lists these connectors, and Figure 2-4 shows their locations. Figure 2-4. View of Rear Panel Table 0-1. Rear Panel Connectors Name REMOTE FAULT Connector is not used. DATA I/O AUX 1 Connector is not used. REF DES J6 J7 Connector Type 9-pin D 9-pin D Function Remote Interface FORM C Fault Relay Contacts J8 J9 37-pin D 9-pin D J10 9-pin D EIA-422 (TTL) Faults Satellite Clock Demod I/Q Automatic Gain Control (AGC) Out FORM C Alarm Relay Contacts RF Output RF Input Input ALARMS Connector is not used. TX/IF OUTPUT RX/IF INPUT EXTERNAL REF AC INPUT GROUND CP1 CP2 CP3 NONE NONE BNC BNC BNC IEC 10-32 Stud Note: The European EMC Directive (EN55022, EN50082-1) requires using properly shielded cables for DATA I/O. These cables must be double-shielded, ensuring a continuous ground shield. 2–7 SNM-1002 LinkSync Modem Installation 2.3.1 Revision 2 MN/SNM1002.OM Remote Connector and Pinouts (J6) The remote connector is a 9-pin female D connector (J6) located on the rear panel of the modem. Screw locks are provided for mechanical security of the mating connector. The remote connector interfaces the M&C functions to the MIDAS Controller. This is an EIA-232 DCE interface. Refer to Appendix A for a description of the remote interface. Refer to Table 0-2 for pinout information. Table 0-2. Remote Connector and Pinouts (J6) EIA-232 Pin # Name 1 2 RD (RX) 3 TD (TX) 4 5 GND 6 DSR 7 RTS 8 CTS 9 2.3.2 Data I/O Interface Connector (J8) This connector is only utilized when the modem is operating in a Redundant LinkSync Configuration. In a Redundant LinkSync Configuration, the Data I/O cable connects between an SNM-301 1:1 Switch and J8 of the LinkSync modem. Refer to Chapter 1, Figure 1-3. 2.3.3 RF Output Connector (CP1) CP1 is a BNC connector for the transmit IF signal. The standard output impedance is 75Ω, and the output power level is -5 to -30 dBm. In normal operation, the output will be a QPSK- or BPSK-modulated signal between 50 and 180 MHz, in 1 Hz steps. 2.3.4 RF Input Connector (CP2) CP2 is a BNC connector for the receive IF signal. The standard input impedance is 75. For normal operation, the desired carrier signal level should be between -30 and -55 dBm. Signals between 50 and 180 MHz are selected and demodulated to produce clock and data at the Data I/O connector. 2–8 SNM-1002 LinkSync Modem Installation 2.3.5 Revision 2 MN/SNM1002.OM External Reference (CP3) CP3 is a BNC connector for an external reference. The input impedance is 75Ω. For normal operation, the reference signal is ≥ 0 dBm. 2.3.6 AC Power Connector The AC power is supplied to the SNM-1002 by a standard, detachable, non-locking, 3-prong power cord. Refer to the following listing for AC power specifications. Input power 50W max. Input voltage 90 to 264 VAC, 47 to 63Hz. Note: Unit switches ranges automatically. 2.3.7 Connector type IEC Fuse protection 1A slo-blo line and neutral fusing 5 mm type fuses. DC Power - Optional For DC supplied units, the DC Power is supplied by terminal lugs installed on the back panel. Refer to the following table for specifications 2.3.8 Input power 50W max. Input voltage 38 to 64 VDC. Connector type Terminal Lug Fuse protection 1A slo-blo 5 mm type fuses. Ground Connector (GND) A #10-32 stud on the rear panel of the modem is used for connecting a common chassis ground among all equipment. Note: The AC power connector provides the safety ground. 2–9 SNM-1002 LinkSync Modem Installation Revision 2 MN/SNM1002.OM This page is intentionally left blank. 2–10 Chapter 3. OPERATION 3.1 Front Panel Note: Front panel operation of the LinkSync modem is only required for initial installation for setting the remote communication parameters. Under normal operation, the MIDAS NMS configures and controls the LinkSync for all of the functions it provides. A complete menu tree is shown for navigational purposes only. The modem front panel (Figure 3-1) enables control of modem configurations parameters and displays the modem status. Figure 3-1. Front Panel View The front panel features include: • • • 32-character, 2-line LCD display 6-button keypad for local control 10 LEDs to provide overall status at a glance 3–1 SNM-1002 LinkSync Modem Operation 3.1.1 Revision 2 MN/SNM1002.OM LED Indicators The 10 LEDs on the front panel indicate: • • • General modem summary faults Status Alarms The indicators are defined in Table 3-1 as follows: Table 3-1. LED Indicators Name LED Transmit Receive Common Stored Red Red Red Yellow Power On Transmitter On Green Green Carrier Detect Test Mode Green Yellow Transmit Receive Yellow Yellow Meaning Faults A fault condition exists in the transmit chain. A fault condition exists in the receive chain. A common equipment fault condition exists. A fault has been logged and stored. The fault may or may not be active. Status Power is applied to the modem. Transmitter is currently on. This indicator reflects the actual condition of the transmitter, as opposed to the programmed condition. Decoder is locked. Flashes when the modem is in a test configuration. Alarms A transmit function is in an alarm condition. A receive function is in an alarm condition. 3–2 SNM-1002 LinkSync Modem Operation 3.1.2 Revision 2 MN/SNM1002.OM Front Panel Keypad The front panel keypad permits local operation of the modem. The keypad consists of six keys (Figure 3-2). It is locked out for normal use. ENTER CLEAR Figure 3-2. Keypad Each key provides one or more logical functions. These functions are defined in the following table. ENTER Left and Right Diamond Keys This key is used to select a displayed function or to execute a modem configuration change. This key is used to back out of a selection or to cancel a configuration change which has not been executed using [ENTER]. Pressing [CLEAR] generally returns the display to the previous selection. These keys are used to move to the next selection or to move the cursor for certain functions. Top and Bottom Diamond Keys Note: Throughout this chapter, [←] and [→] are used to indicate left and right diamond keys. These keys are used primarily to change configuration data (numbers). At times, they are also used to move from one section to another. CLEAR Note: Throughout this chapter, [↑] and [↓] are used to indicate top and bottom diamond keys. The modem responds by beeping whenever a key is pressed: • A single beep indicates a valid entry and the appropriate action was taken. • A double beep indicates an invalid entry or a parameter is not available for operation. 3–3 SNM-1002 LinkSync Modem Operation 3.2 Revision 2 MN/SNM1002.OM Menu System Use the Main menu in Figure 3-3 as a quick reference for accessing the modem functions. When the modem power is applied, the base level of the menu system displays the sign-on message: • • Line 1 of the sign-on message is the modem type. Line 2 is the node address. The main level of the menu system is Function Select. To access this level from the sign-on message, press the [←] or [→] keys. From the Function Select menu, select one of the functional categories: • • • • • Configuration Monitor Faults/Alarms Stored Faults/Alarms Utility Press [←] or [→] to move from one selection to another. When line 2 displays the desired function, select that level by pressing [ENTER]. After entering the appropriate functional level, press [←] or [→] to move to the desired function. To view the modem’s configuration, enter the Configuration level from the Function Select menu. Once in the Configuration menu, press [←] or [→] to scroll through the Configuration menu selection: • • • • • Modulator Demodulator Interface Save Recall Press [ENTER] to select the desired Configuration menu option. To view the options for the selected configuration parameters, press [←] or [→]. Notes: 1. Menus or commands that are specific to certain modem configurations are only accessible after selecting the appropriate modem configuration. This prevents incompatible parameters from accidentally being selected. 3. All of the windows are accessible in the Custom mode. Take caution not to select incompatible parameters, as the modem does not shut out incompatible command choices in the Custom mode. 3–4 SNM-1002 LinkSync Modem Operation 3.3 Revision 2 MN/SNM1002.OM Front Panel Menu SELECT CONFIGURATION MONITOR FAULTS/ALARMS STORED FLTS/ALMS UTILITY CODE/DATA RATE TX-IF FREQUENCY TX-IF OUTPUT TX POWER LEVEL SCRAMBLER DIFF ENCODER CARRIER MODE MODEM REFERENCE MODULATOR DEMODULATOR INTERFACE SAVE RECALL RAW BER CORRECTED BER EB/NO RECEIVE SIGNAL SWEEP FREQUENCY BUFFER FILL CODE/DATA RATE RX-IF FREQUENCY DESCRAMBLER DIFF DECODER RF LOOP BACK IF LOOP BACK BER THRESHOLD SWEEP CENTER SWEEP RANGE REACQUISITION MODULATOR DEMODULATOR TX INTERFACE RX INTERFACE COMMON MODULATOR DEMODULATOR TX INTERFACE RX INTERFACE COMMON CLEAR TX CLOCK SOURCE TX CLOCK PHASE EXT-CLK FREQ BUFFER CLOCK RX CLOCK PHASE B-BAND LOOP BACK BUFFER SIZE BUFFER CENTER LOOP TIMING MODULATOR DEMODULATOR INTERFACE SYSTEM MODEM TYPE ASSIGNED FILTERS MOD POWER OFFSET MODULATOR TYPE ENCODER TYPE TX BPSK OREDERING MOD SPECTRUM TX SYMBOL RATE FACTORY SETUP (NOT APPLICABLE ASSIGNED FILTERS DEMODULATOR TYPE DECODER TYPE RX BPSK ORDERING DEMOD SPECTRUM RX SYMBOL RATE TX OVERHEAD TYPE RX OVERHEAD TYPE TX TERR INTERFACE RX TERR INTERFACE BUFFER PROGRAM FRAMING STRUCTURE RTS TX-IF CNTRL TX DATA PHASE RX DATA PHASE CTS DELAY TIME/DATE REMOTE BAUD RATE REMOTE ADDRESS REMOTE TYPE OPERATION MODE YEAR DISPLAY TEST MODE STATUS LAMP TEST SELF TEST DISPLAY CONTRAST M&C FIRMWARE BOOT FIRMWARE FPGA FIRMWARE DEMO MODE EXT AGC: MAX PWR EXT AGC: MIN PWR MASTER RESET MODEM TYPE MODEM EMULATION REV EMULATION MODEM OPTIONS LOCAL MODEM AUPC MODEM SERIAL CONFIGURATION CODE Figure 3-3. Main Menu 3–5 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM Note: The following menus tree shows the modem functions available for an SNM-1002 LinkSync Modem. The defaulkt settings used when deployed in a MIDAS Network are underlined. 3.4 OPENING SCREEN SNM 1002 Ver:X.X.X 3.4.1 FUNCTION SELECT:CONFIGURATION FUNCTION SELECT CONFIGURATION The main level of the menu system is Function Select. To access this level from the sign-on message, press the [←] or [→] keys. From the Function Select menu, select one of the functional categories: • • • • • Configuration Monitor Faults/Alarms Stored Faults/Alarms Utility Press [←] or [→] to move from one selection to another. When line 2 displays the desired function, select that level by pressing [ENTER]. After entering the appropriate functional level, press [←] or [→] to move to the desired function. 3–6 SNM-1002 LinkSync Modem Operation 3.4.1.1 Revision 2 MN/SNM1002.OM CONFIGURATION:MODULATOR CONFIGURATION MODULATOR To view the modem’s configuration, enter the Configuration level from the Function Select menu. Once in the Configuration menu, press [←] or [→] to scroll through the Configuration menu selection: • • • • • Modulator Demodulator Interface Save Recall Press [ENTER] to select the desired Configuration menu option. To view the options for the selected configuration parameters, press [←] or [→]. 3.4.1.1.1 MODULATOR: CODE RATE/TYPE TX-X QPSK 1/2 19.200 kbps Transmit code rate/type as follows: TX-A QPSK 1/2 19.200 kbps TX-B QPSK 1/2 19.200 kbps TX-C QPSK 1/2 19.200 kbps TX-D QPSK 1/2 19.200 kbps TX-V QPSK 1/2 19.200 kbps Upon entry, the current transmitter rate is displayed. 3–7 SNM-1002 LinkSync Modem Operation 3.4.1.1.2 Revision 2 MN/SNM1002.OM MODULATOR:TX-IF FREQENCY TX-IF FREQUENCY 70.000000 MHz Displays the modulator TX IF frequency between 50 and 180 MHz, in 1 Hz steps. Upon entry, the current transmitter frequency is displayed with the flashing cursor on the first character. Press [← ] or [→] to move the flashing cursor, and [↑ ] or [↓ ] to increase or decrease the digit at the flashing cursor. Press <ENTER> to execute the change. 3.4.1.1.3 MODULATOR:TX-IF OUTPUT TX-IF OUTPUT ON Displays the modulator output status, either On or Off. Upon entry, the current TX-IF output is displayed with the flashing cursor on the first character. Press [↑ ] or [↓ ] to On or Off. Press <ENTER> to execute the change. 3.4.1.1.4 MODULATOR:TX POWER LEVEL TX POWER LEVEL -10.0 dBm Displays the modulator output level from: • -5.0 to –30.0 dBm (Normal Range) Upon entry, the current TX power level is displayed with the flashing cursor on the first character. Press [← ] or [→] to move the flashing cursor, and [↑ ] or [↓ ] to increase or decrease the digit at the flashing cursor. Press <ENTER> to execute the change. 3–8 SNM-1002 LinkSync Modem Operation 3.4.1.1.5 Revision 2 MN/SNM1002.OM MODULATOR:SCRAMBLER SCRAMBLER ON Displays the scrambler status, either On or Off. Upon entry, the current scrambler is displayed with the flashing cursor on the first character. Press [↑ ] or [↓ ] to change the carrier mode. Press <ENTER> to execute the change 3.4.1.1.6 MODULATOR:DIFF. ENCODER DIFF. ENCODER ON Displays the differential encoder status, either On or Off. Upon entry, the current differential decoder is displayed with the flashing cursor on the first character. Press [↑ ] or [↓ ] to change the carrier mode. Press <ENTER> to execute the change. 3–9 SNM-1002 LinkSync Modem Operation 3.4.1.1.7 Revision 2 MN/SNM1002.OM MODULATOR:CARRIER MODE CARRIER MODE NORMAL-MODULATED Displays the carrier mode of operation as follows: Normal-Modulated The carrier mode in normally in this Modulated position. Center-CW Generates a carrier at the current modulator frequency. This can be used to measure the output frequency. Offset-CW Generates a single, upper, side-band-suppressed carrier signal. The upper sideband is at one-quarter of the symbol rate from the carrier. When inverted spectrum is selected, this generates a single, lower, side-band-suppressed carrier. Dual-CW Generates a dual side-band suppressed carrier signal. Side-bands are at one-half of the symbol rate from the carrier. This is used to check the channel balance and carrier null. Upon entry, the current carrier mode is displayed with the flashing cursor on the first character. Press [↑ ] or [↓ ] to change the carrier mode. Press <ENTER> to execute the change. 3.4.1.1.8 MODULATOR:MODEM REFERENCE MODEM REFERENCE INTERNAL Displays the following references to the modulator: • • INTERNAL EXT1, EXT5, EXT10, and EXT20 MHz Note: If any EXT REF is selected for the modem reference and there is no input to CP3, the modem will detect an alarm and switch to the INTERNAL clock. Upon entry, the current modem reference is displayed with the flashing cursor on the first character. Press [↑ ] or [↓ ] change the modem reference. Press <ENTER> to execute the change. 3–10 SNM-1002 LinkSync Modem Operation 3.4.1.2 Revision 2 MN/SNM1002.OM CONFIGURATION:DEMODULATOR CONFIGURATION DEMODULATOR 3.4.1.2.1 DEMODULATOR:CODE RATE/TYPE RX-X QPSK 1/2 19.200 kbps Receive code rate/type as follows: RX-A QPSK 1/2 19.200 kbps RX-B QPSK 1/2 19.200 kbps RX-C QPSK 1/2 19.200 kbps RX-D QPSK 1/2 19.200 kbps RX-V QPSK 1/2 19.200 kbps Upon entry, the current transmitter rate is displayed. Press [↑ ] or [↓ ] change the assigned filter. Press <ENTER> to execute the change. 3.4.1.2.2 DEMODULATOR:RX-IF FREQUENCY RX-IF FREQUENCY 70.000000 MHZ Displays the demodulator receive frequency, between 50 and 180 MHz, in 1 Hz steps. Upon entry, the current RF-IF frequency is displayed. Press [↑ ] or [↓ ] change the assigned filter. Press <ENTER> to execute the change. 3–11 SNM-1002 LinkSync Modem Operation 3.4.1.2.3 Revision 2 MN/SNM1002.OM DEMODULATOR:DESCRAMBLER DESCRAMBLER ON Displays the descrambler status, either On or Off. Upon entry, the current descrambler is displayed. Press [↑ ] or [↓ ] change the assigned filter. Press <ENTER> to execute the change. 3.4.1.2.4 DEMODULATOR:DIFF.DECODER DIFF. DECODER ON Displays the differential decoder status, either On or Off. Upon entry, the current differential decoder is displayed. Press [↑ ] or [↓ ] change the assigned filter. Press <ENTER> to execute the change. 3.4.1.2.5 DEMODULATOR:RF LOOP BACK RF LOOP BACK OFF Displays the RF loop back status, either On or Off. Upon entry, the current RF loop back is displayed. Press [↑ ] or [↓ ]. Press <ENTER> to execute the change. 3–12 SNM-1002 LinkSync Modem Operation 3.4.1.2.6 Revision 2 MN/SNM1002.OM DEMODULATOR:IF LOOP BACK IF LOOP BACK OFF Displays the IF loop back status, either On or Off. Upon entry, the current IF loop back is displayed. Press [↑ ] or [↓ ]. Press <ENTER> to execute the change. 3.4.1.2.7 DEMODULATOR:BER THRESHOLD BER THRESHOLD NONE Displays the BER threshold . If the BER threshold set is exceeded, a receive fault will be indicated by the modem status indicators. BER threshold may be set from 1.0 E-3 to 1.0 E-8, or may be disabled by specifying NONE. Upon entry, the current BER threshold is displayed. Press [↑ ] or [↓ ]. Press <ENTER> to execute the change. 3.4.1.2.8 DEMODULATOR:SWEEP CENTER SWEEP CENTER + 0 HZ Displays the sweep center frequency for the directed sweep function. When in directed sweep, the value from the sweep monitor screen (when the modem was last locked) should be entered for the sweep center frequency. The sweep center frequency can be set in the range from –35000 to +35000 Hz. Default: 0 Hz. Upon entry, the current sweep center frequency is displayed with the flashing cursor on the first character. Press [← ] or [→] to move the flashing cursor, and [↑ ] or [↓ ] to increase or decrease the digit at the flashing cursor. Press <ENTER> to execute the change. 3.4.1.2.9 DEMODULATOR:SWEEP RANGE 3–13 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM SWEEP RANGE 60000 HZ Displays the overall travel of the sweep width range during acquisition in the directed sweep mode. The sweep width may be set from 0 to 70000 Hz. Default: 60000 Hz. When set at 70000 Hz, the modem is in Normal acquisition mode. The smaller the range, the faster the modem will lock, provided the receive carrier center frequency is within the RX-IF frequency sweep range. 3.4.1.2.10 DEMODULATOR:REACQUISITION REACQUISITION 0 SECONDS Displays the sweep reacquisition mode time duration. This is the time that the modem will remain in a narrow sweep after loss of acquisition. After this timer runs out, the modem will return to the normal acquisition sweep. The reacquisition time is 0 to 999 seconds. Default: 0 seconds. 3–14 SNM-1002 LinkSync Modem Operation 3.4.1.3 Revision 2 MN/SNM1002.OM CONFIGURATION:INTERFACE CONFIGURATION INTERFACE 3.4.1.3.1 INTERFACE:TX CLOCK SOURCE TX CLOCK SOURCE SCT (INTERNAL) Programs the clock source for the modem transmitter clock to the following configurations: TX TERRESTRIAL Sets the TX clock to recover timing from the incoming clock/data. SCT (INTERNAL) Sets the TX clock to operate from the modem internal clock (this also is the fallback clock). Note: When loop timing is enabled, SCT (LOOP) is displayed instead of SCT (INTERNAL). RX (SATELLITE) Sets the RX clock to recover timing from the output clock/data. EXT CLOCK Sets the TX clock to operate from the EXT-CLK clock. Transmit clock source must be phase/frequency locked to the data that is being transmitted. The correct frequency must be programmed into EXT-CLK FREQ. Upon entry, the current TX clock source is displayed. Press [↑ ] or [↓ ] to make the selection. Press <ENTER> to execute the change. 3–15 SNM-1002 LinkSync Modem Operation 3.4.1.3.2 Revision 2 MN/SNM1002.OM INTERFACE:TX CLOCK PHASE TX CLOCK PHASE INVERT Programs the TX clock phase to AUTO, NORMAL, INVERT. Upon entry, the current TX clock phase is displayed. Press [↑ ] or [↓ ] to make the selection. When AUTO is s elected, the modem will automatically select NORMAL or INVERT to properly phase the TX clock with the TX data. Press <ENTER> to execute the change. 3.4.1.3.3 INTERFACE:EXT-CLK FREQ EXT-CLK FREQ 1544.000 KHZ Programs the external reference clock input frequency between 8.0 kHz and 10.0 MHz. Default: 1544 kHz. Note: The clock rate must be equal to the data rate unless the asymmetrical loop timing option is present. This clock frequency can be any multiple of 600 Hz from 2.4 to 64 kHz, and can be any multiple of 8 kHz from 64 kHz to 4.376 MHz. This can be used for the Doppler/plesiochronous buffer reference. It can be a reference to SCT. Use the master clock input on J8 for the external master reference. The EXT REF on CP3 only allows for 1, 5, 10, and 20 MHz external reference input. Upon entry, the current setting for the external reference is displayed. Press [←] or [→] to increment or decrement the digit at the flashing cursor. Press [ENTER] to execute the change. 3–16 SNM-1002 LinkSync Modem Operation 3.4.1.3.4 Revision 2 MN/SNM1002.OM INTERFACE:BUFFER CLOCK BUFFER CLOCK RX (SATELLITE) Programs the interface buffer output clock to one of the following modes: RX (SATELLITE) Sets the output buffer clock to the satellite clock. (This is a Bypass.) SCT (INTERNAL) Sets the buffer clock to operate from the modem internal clock. This is also the fallback clock. EXT. CLOCK Sets this clock source to the external clock. TX TERRESTRIAL Sets the buffer output clock to recover timing from the incoming TX data clock. INSERT CLOCK Selects the recovered clock from the insert send data input received from the terrestrial equipment. Upon entry, the current setting of the plesiochronous buffer clock is displayed. Press [↑] or [↓] to make the selection. Press [ENTER] to execute the change. 3.4.1.3.5 INTERFACE:RX CLOCK PHASE RX CLOCK PHASE NORMAL Programs the RX clock phase to Normal or Inverted. Upon entry, the status of the RX Clock is displayed. Press [↑] or [↓] to make the selection. Press [ENTER] to execute the change. 3–17 SNM-1002 LinkSync Modem Operation 3.4.1.3.6 Revision 2 MN/SNM1002.OM INTERFACE:B-BAND LOOP BACK B-BAND LOOP BACK OFF Programs the modem for baseband loopback operation, On or Off. When baseband loopback is turned on, the data and timing signals are switched from the demodulator to the modulator on the modem side of the interface. The DTE baseband signals are also looped back from the transmitter data and clock to receiver data and clock on the customer side of the interface. This is a bi-directional loopback of the baseband data. Refer to figure 3-4 for a block diagram of baseband loopback operation. Upon entry, the status is displayed. Press [↑] or [↓] to make the selection. Press [ENTER] to execute the change. CUSTOMER DATA IBS OR IDR ENCODER/ MODULATOR TRANSMIT RF EQUIPMENT INTERFACE ANTENNA REMOTE SERIAL INTERFACE MICROCOMPUTER POWER SUPPLY AC POWER FAULT INDICATORS DEMODULATOR/ DECODER RECEIVE RF EQUIPMENT SATELLITE MODEM Figure 3-4. Baseband Loopback Note: When baseband loopback is turned on, data is looped back on the customer side of the interface. This is a bi-directional loopback of the baseband data. This test mode will verify the customer equipment and cabling between the modem and the customer equipment. The baseband loopback is not bi-directional in D&I. 3–18 SNM-1002 LinkSync Modem Operation 3.4.1.3.7 Revision 2 MN/SNM1002.OM INTERFACE:BUFFER SIZE BUFFER SIZE 0 (BYPASS) Sets the size of the buffer, 32 to 262144 bits, 1 to 99 mS , or 0 (Bypass) Upon entry, the current buffer length is displayed. Press [↑] or [↓] to select the desired buffer size. The buffer size is displayed in seconds or bits. Enter the Utility Interface menu to change the buffer units to seconds or bits. • • • If selecting seconds, choose from 1 to 99 ms, in increments of 1 ms, or 0 (Bypass). If selecting bits, choose from 32 to 262144 bits, in increments of 16 bits. Press [ENTER] to execute the change. Note: To have the modem calculate the plesiochronous shift, set the buffer units to ms. When a specific buffer depth is desired, set the buffer units to bits. Select bits or ms from the Utility Interface menu. 3.4.1.3.8 INTERFACE:BUFFER CENTER BUFFER CENTER YES/NO This configuration function is used to center the buffer. Choosing YES centers the buffer. Press <ENTER> twice to center the buffer. 3.4.1.3.9 INTERFACE:LOOP TIMING 3–19 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM LOOP TIMING OFF The SCT output will become phase-locked to the RX satellite clock. TX and RX data rates must be equal unless the asymmetrical loop timing option is On or Off. Upon entry, the status is displayed. Press [↑] or [↓] to make the selection. Press [ENTER] to execute the change. 3.4.1.4 CONFIGURATION:SAVE CONFIGURATION SAVE The Configuration Save menu allows programming of configuration parameters into memory on the M&C. There are five memory locations that may be used to store specific configuration setups that are used frequently. After changing the configuration parameters to the desired settings, enter the Configuration Save menu and select memory location 1 through 5. Press [ENTER] to execute the save. 3.4.1.5 CONFIGURATION:RECALL CONFIGURATION RECALL The Configuration Recall menu allows the user to recall a previously saved configuration setup. Upon entry, select memory location 1 through 5 by pressing [↑] or [↓]. Press [ENTER] to execute the recall. 3.4.2 FUNCTION SELECT:MONITOR 3–20 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM FUNCTION SELECT MONITOR 3.4.2.1 MONITOR:RAW BER RAW BER NO DATA Displays the current BER or “No Data” (if carrier is not locked). Range: < m.m E-e to > m.m E-e. Note: Low limit is based on performance. High limit is based on data/code rate. 3.4.2.2 MONITOR:CORRECTED BER CORRECTED BER NO DATA Displays the current corrected BER or “No Data” (if carrier is not locked). Range: 1.0 E-3 to 1.0 E-12. Note: Low limit is based on performance. High limit is 1.0 E-12. 3.4.2.3 MONITOR:EB/NO EB/NO 16.0 Displays the current Eb/N0 or “No Data” (if carrier is not locked). Range: 2.0 to 16.0 dB. Note: Low limit is based on the data rate. High limit is 16.0 dB. 3.4.2.4 MONITOR:RECEIVE SIGNAL 3–21 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM RECEIVE SIGNAL -60.0 DBM Displays the current receive signal level. Range: -25.0 to -60.0 dBm. 3.4.2.5 MONITOR:SWEEP FREQUENCY SWEEP FREQUENCY + 0 HZ Displays the current offset frequency or “No Data” (if carrier is not locked). Range: -35,000 to +35,000 Hz. 3.4.2.6 MONITOR:BUFFER FILL BUFFER FILL 50% Displays the current plesiochronous buffer fill status percent. Range: 1 to 99%. 3.4.3 FUNCTION SELECT:FAULTS/ALARMS 3–22 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM FUNCTION SELECT FAULTS/ALARMS The Faults/Alarms menu is accessible from the Function Select menu. The Faults/Alarms are similar to monitor functions, as they display the current fault status of the group being displayed. Press [←] or [→] to move between the following Faults/Alarms groups: • • • • • Modulator Demodulator Transmit Interface Receive Interface Common Equipment Line 2 of the display shows the current Faults/Alarms status in real time. For each parameter monitored, fault status is displayed as one of the following: • • • “–” indicates that no fault or alarm exists. “+” indicates that a fault exists, and will cause switching in a redundant system. Reversed contrast “+” indicates an active alarm. Unlike faults, alarms do not cause switching to occur. To display labels for individual faults or alarms, press [ENTER]. Press [←] or [→] to move the flashing cursor to make the selection. The label for that Fault/Alarm is then displayed on line 1 of the display. Press [CLEAR] to exit this level of operation and return to the previous level. The following sections outline the faults and alarms monitored and displayed in each group. 3–23 SNM-1002 LinkSync Modem Operation 3.4.3.1 Revision 2 MN/SNM1002.OM FAULTS AND ALARMS:MODULATOR MODULATOR +-------- 3.4.3.2 IF SYNTHESIZER Modulator IF synthesizer fault. DATA CLOCK SYN Transmit clock synthesizer fault. Indicates the internal Voltage Controlled Oscillator (VCO) has not locked to the incoming data clock. I CHANNEL I channel data activity fault. Q CHANNEL Q channel data activity fault. AGC LEVEL TX IF AGC level fault. MODEM REF ACT MODEM REF activity alarm. MODEM REF PLL MODEM REF PLL not locked. MODULE Modulator module fault. CONFIGURATION Modulator configuration fault. FAULTS AND ALARMS:DEMODULATOR DEMODULATOR +-++----CARRIER DETECT IF SYNTHESIZER Carrier detect fault. Indicates the decoder is not locked. Demodulator IF synthesizer fault. Indicates the IF synthesizer is not locked. I CHANNEL I channel activity fault. Indicates a loss of activity in the I channel of the quadrature demodulator. Q CHANNEL Q channel activity fault. Indicates a loss of activity in the Q channel of the quadrature demodulator. BER THRESHOLD Secondary alarm result of the BER threshold set in the DEMOD Configuration menu. MODULE Demodulator/decoder module fault. CONFIGURATION Demodulator/decoder configuration fault. 3–24 SNM-1002 LinkSync Modem Operation 3.4.3.3 Revision 2 MN/SNM1002.OM FAULTS AND ALARMS:TX INTERFACE TX INTERFACE --------TX DROP Not Applicable. TX DATA/AIS Data or AIS. When data fault is selected in the Interface Configuration menu, the fault indicates a data stable condition. This indicates the data is all 1s or 0s (i.e., data is not transitioning). When AIS is selected, the alarm indicates the data is all 1s from customer data input to the modem. When None is selected in the Interface Configuration menu, the TX Data/AIS Fault/Alarm is not activated. Note: AIS is an alarm, not a switching fault. TX CLK PLL Transmitter phase-locked loop fault. Indicates the transmitter Phase-Locked Loop (PLL) is not locked. TX CLK ACTIVITY Activity detector alarm of the selected interface transmit clock. The interface will fall back to the internal clock when this alarm is active. TX AUDIO 1 CLIP Not Applicable. TX AUDIO 2 CLIP Not Applicable. CONFIGURATION TX interface configuration fault. Indicates the TX interface cannot execute a programmed configuration parameter. 3–25 SNM-1002 LinkSync Modem Operation 3.4.3.4 Revision 2 MN/SNM1002.OM FAULTS AND ALARMS:RX INTERFACE RX INTERFACE --------BUFFER UNDERFLOW Buffer underflow alarm. Indicates that a buffer underflow has occurred. BUFFER OVERFLOW Buffer overflow alarm. Indicates that a buffer overflow has occurred. RX DATA/AIS Data or AIS. When data fault is selected in the Configuration Interface menu, the fault indicates a data stable condition. This indicates the data coming from the satellite is all 1s or 0s (i.e., data is not transitioning). When AIS is selected, the Alarm indicates the data is all 1s from the satellite. When None is selected in the Configuration Interface menu, the RX Data/AIS Fault/Alarm is not activated. Note: AIS is an alarm, not a switching fault. FRAME BER Frame BER fault. Indicates that the frame BER exceeds 1-3. BACKWARD ALARM Not Applicable. BUFFER CLK PLL Buffer clock phase-locked loop fault. Indicates the buffer clock PLL is not locked. BUFFER CLK ACT Activity detector alarm of the selected interface receive clock. The interface will fall back to the satellite clock when this fault is active. DEMUX LOCK DEMUX lock fault. Indicates that the DEMUX is not locked. RX 2047 LOCK RX 2047 lock alarm. Indicates the RX 2047 data pattern is not locked. Note: This alarm is only active if RX 2047 is ON. BUFFER FULL Buffer full alarm. Indicates the buffer is less than 10% or greater than 90% full. RX INSERT Not Applicable. RX AUDIO 1 CLIP Not Applicable. RX AUDIO 2 CLIP Not Applicable. CONFIGURATION Configuration alarm. 3–26 SNM-1002 LinkSync Modem Operation 3.4.3.5 Revision 2 MN/SNM1002.OM FAULTS AND ALARMS:COMMON COMMON --------- BATTERY/CLOCK Battery or clock fault. -12V SUPPLY -12V power supply fault. +12V SUPPLY +12V power supply fault. +5V SUPPLY +5V power supply fault. SELF TEST Self Test Fault. Indicates a selt test fault if the transmitted signal is not not received. CONTROLLER Controller fault. Typically indicates the controller has gone through a power on/off cycle. INTERFACE MODULE Interface module fault. Typically indicates that the interface module is missing or will not program. 3–27 SNM-1002 LinkSync Modem Operation 3.4.4 Revision 2 MN/SNM1002.OM FUNCTION SELECT:STORED FLTS/ALMS FUNCTION SELECT STORED FLTS/ALAMS The modem stores the first 10 (Flt0 through Flt9) occurrences of fault status changes in each of the following major fault categories: • • • • • Modulator Demodulator Transmit Interface Receive Interface Common Equipment Each fault status change is stored with the time and date of the occurrence of the fault. Stored faults may be viewed by entering the stored faults level from the Select menu. Stored faults are not maintained through controller power-on reset cycle. However, the last known time is maintained in nonvolatile Random Access Memory (RAM). On power-up, a common equipment fault is logged (Flt0) with that last known time and date. In addition, on power-up, an additional common equipment fault is logged (Flt1) to indicate the power-up time and date. The power-down and power-up times are logged as common equipment fault 0 and common equipment fault 1, respectively. On entering the stored faults level, press [←] or [→] to move between the fault groups and the “Clear Stored Faults ?” selections. The time and date of the first stored fault status (Flt0) for the selected group will be displayed alternately on line 2 of the display. Press [↑] or [↓] to cycle through the selected group has stored fault status (Flt0 through Flt9). To display the fault status associated with the displayed time and date, press [ENTER]. To identify the fault, press [←] or [→] to move the flashing cursor. To clear the currently logged stored faults, press [ENTER] when the “Clear Stored Faults/Yes?” selection is displayed. Note: Faults are stored in time sequence, with the oldest fault status change stored in Flt0, and the most recent in Flt9. Only the first 10 fault status changes are stored. All stored faults, which have not been used, indicate “No Fault” on the display. 3–28 SNM-1002 LinkSync Modem Operation 3.4.4.1 Revision 2 MN/SNM1002.OM STORED FLTS/ALMS:MODULATOR MODULATOR X STORED TIME/DATE (FAULT LABEL) --------IF Synthesizer DATA CLOCK SYN I CHANNEL Q CHANNEL AGC LEVEL MODEM REF ACT MODEM REF PLL MODULE CONFIGURATION 3.4.4.2 STORED FLTS/ALMS:DEMODULATOR DEMODULATOR STORED TIME/DATE X (FAULT LABEL) --------CARRIER DETECT IF SYNTHESIZER I CHANNEL Q CHANNEL BER THRESHOLD MODEL CONFIGURATION 3.4.4.3 STORED FLTS/ALMS:TX INTERFACE 3–29 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM TX INTERFACE STORED TIME/DATE X (FAULT LABEL) --------TX DROP TX DATA/AIS TX CLK PLL TX CLK ACTIVITY TX AUDIO 1 CLIP TX AUDIO 2 CLIP CONFIGURATION 3.4.4.4 (Not Applicable) (Not Applicable) (Not Applicable) STORED FLTS/ALMS:RX INTERFACE 3–30 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM RX INTERFACE STORED TIME/DATE X (FAULT LABEL) --------BUFFER UNDERFLOW BUFFER OVERFLOW RX DATA/AIS FRAME BER BACKWARD ALARM BUFFER CLK PLL BUFER CLK ACT DEMUX LOCK RX 2047 LOCK BUFFER FULL RX INSERT RX AUDIO 1 CLIP RX AUDIO 2 CLIP CONFIGURATION 3.4.4.5 (Not Applicable) (Not Applicable) (Not Applicable) (Not Applicable) STORED FLTS/ALMS:COMMON 3–31 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM COMMON X STORED TIME/DATE (FAULT LABEL) --------BATTERY/CLOCK -12 VOLT SUPPLY +12 VOLT SUPPLY +5 VOLT SUPPLY SELF TEST CONTROLLER INTERFACE MODULE 3.4.4.6 STORED FLTS/ALMS:CLEAR CLEAR ?? STORED FAULTS 3–32 SNM-1002 LinkSync Modem Operation 3.4.5 Revision 2 MN/SNM1002.OM FUNCTION SELECT:UTILITY FUNCTION SELECT UTILITY The Function Select Utility menu is divided into the following categories: • • • • • • • Modulator Demodulator Interface Network System Modem Type Factory Setup The menu information includes: • • • • • • • • • • • Filter Types Terrestrial Interface Types Mod/Demod Types Time/Date Encoder/Decoder Types Modem Types Current Firmware Test Mode Status Overhead Type Revision Emulation Lamp Test Provisions are also made for assigning data and code rates to the modulator and demodulator. After entering the Utility menu, press [←] or [→] to select the desired sub-menu, and press [ENTER]. Notes: 1. The Utility Factory Setup menu is for Comtech EF Data service personnel only. Entering this menu without authorization may cause the modem to operate incorrectly. 2. Changes in the Utility menu may cause changes in other front panel menus. 3–33 SNM-1002 LinkSync Modem Operation 3.4.5.1 Revision 2 MN/SNM1002.OM UTILITY:MODULATOR UTILITY MODULATOR 3.4.5.1.1 MODULATOR: ASSIGN TRANSMIT FILTERS ASSIGN TRANSMIT FILTERS Transmit code rate/type as follows: TX-A QPSK 1/2 19.200 kbps TX-B QPSK 1/2 19.200 kbps TX-C QPSK 1/2 19.200 kbps TX-D QPSK 1/2 19.200 kbps TX-V QPSK 1/2 19.200 kbps Upon entry, the current transmitter rate is displayed. 3.4.5.1.2 MODULATOR:MOD POWER OFFSET MODEM POWER OFFSET + 0.0 DB Modulator power offset adjust. Offsets the modulator output power readout in the Configuration menu. This feature does not actually change the modulator power level, but displays an offset value in the monitor. The modulator power offset range is -99.9 to +99.9 dB, in 0.1 dB steps. Note: Anything except 0.0 dB will cause ADJ to be displayed for the TX power level. 3–34 SNM-1002 LinkSync Modem Operation 3.4.5.1.3 Revision 2 MN/SNM1002.OM MODULATOR:MODULATOR TYPE MODULATOR TYPE INTELSAT OPEN Transmit filter type select. Select one of the following for network filtering: Note: Change in EFD, ASYNC, or Custom modem types only. INTELSAT OPEN EFD CLOSED CSC CLOSED FDC CLOSED SDM-51 COMPATIBLE Notes: 1. TX filter type is selectable only when CUSTOM is selected for the modem type in the Utility Modem Type menu. 2. Code Rate 3/4 is not compatible with a combination of a CSC CLOSED Modulator Type and Sequential Encoder. 3.4.5.1.4 MODULATOR:ENCODER TYPE ENCODER TYPE VITERBI Encoder type selection. Select VITERBI or SEQUENTIAL encoder type. Notes: 1. Change in EFD, ASYNC, or Custom modem types only. 2. A Sequential Encoder Type and a 3/4 Code Rate combination is not compatible with a CSC CLOSED Modulator Type. Press[←], [→], [↑], or [↓] to move the flashing cursor. Press [ENTER] to execute the change. 3–35 SNM-1002 LinkSync Modem Operation 3.4.5.1.5 Revision 2 MN/SNM1002.OM MODULATOR:TX BPSK ORDERING TX BPSK ORDERING STANDARD Transmit BPSK bit ordering selection. Select STANDARD or NON-STANDARD Press[←], [→], [↑], or [↓] to move the flashing cursor. Press [ENTER] to execute the change. 3.4.5.1.6 MODULATOR:MOD SPECTRUM MOD SPECTRUM NORMAL Programmable vector rotation allows the operator to select NORMAL or INVERT for spectrum reversal of the I and Q baseband channels. Press[←], [→], [↑], or [↓] to move the flashing cursor. Press [ENTER] to execute the change 3.4.5.1.7 MODULATOR:TX SYMBOL RATE TX SYMBOL RATE 19.200 KSPS Status only. Selects TX Symbol Data rate. 3.4.5.2 UTILITY:DEMODULATOR UTILITY DEMODULATOR 3–36 SNM-1002 LinkSync Modem Operation 3.4.5.2.1 Revision 2 MN/SNM1002.OM DEMODULATOR:ASSIGN RECEIVE FILTERS ASSIGN RECEIVE FILTERS Receive code rate/type as follows: RX-A QPSK 1/2 19.200 kbps RX-B QPSK 1/2 19.200 kbps RX-C QPSK 1/2 19.200 kbps RX-D QPSK 1/2 19.200 kbps RX-V QPSK 1/2 19.200 kbps Upon entry, the current transmitter rate is displayed. 3.4.5.2.2 DEMODULATOR: DEMODULATOR TYPE DEMODULATOR TYPE INTELSAT OPEN Transmit filter type select. Select one of the following for network filtering: Note: Change in EFD, ASYNC, or Custom modem types only. INTELSAT OPEN EFD CLOSED CSC CLOSED FDC CLOSED SDM-51 COMPATIBLE Notes: 1. TX filter type is selectable only when CUSTOM is selected for the modem type in the Utility Modem Type menu. 2. Code Rate 3/4 is not compatible with a combination of a CSC CLOSED Modulator Type and Sequential Encoder. 3.4.5.2.3 DEMODULATOR:DECODER TYPE DECODER TYPE VITERBI 3–37 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM Decoder type selection. Select VITERBI or SEQUENTIAL decoder type. Notes: 1. Change in EFD, ASYNC, or Custom modem types only. 2. A Sequential Decoder Type and a 3/4 Code Rate combination is not compatible with a CSC CLOSED Modulator Type. Press[←], [→], [↑], or [↓] to move the flashing cursor. Press [ENTER] to execute the change. 3.4.5.2.4 DEMODULATOR:RX BPSK ORDERING RX BPSK ORDERING STANDARD Receive BPSK bit ordering selection. Select STANDARD or NON-STANDARD Press[←], [→], [↑], or [↓] to move the flashing cursor. Press [ENTER] to execute the change. 3.4.5.2.5 DEMODULATOR:DEMOD SPECTRUM DEMOD SPECTRUM NORMAL Programmable vector rotation allows the operator to select NORMAL or INVERT for spectrum reversal of the I and Q baseband channels. Press[←], [→], [↑], or [↓] to move the flashing cursor. Press [ENTER] to execute the change. 3.4.5.2.6 DEMODULATOR:RX SYMBOL RATE RX SYMBOL RATE 3–38 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM 19.200 KSPS Status only. Selects RX Symbol Data rate, with 4.800 to 2500.000 ksps. 3.4.5.3 UTILITY:INTERFACE UTILITY INTERFACE 3.4.5.3.1 INTERFACE:TX OVERHEAD TYPE TX OVERHEAD TYPE NONE Select None for TX overhead type. Note: Overhead types are selectable only when Custom is selected for modem type in the Utility Modem Type menu. 3.4.5.3.2 INTERFACE:RX OVERHEAD TYPE RX OVERHEAD TYPE NONE Select None RX overhead type. Note: Overhead types are selectable only when Custom is selected for modem type in the Utility Modem Type menu. 3.4.5.3.3 INTERFACE:TX TERR INTERFACE TX TERR INTERFACE 3–39 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM RS422 Displays the TX interface type RS-232, RS-422, or V.35. 3.4.5.3.4 INTERFACE:RX TERR INTERFACE RX TERR INTERFACE RS422 Displays the RX interface type RS-232, RS-422, or V.35. 3.4.5.3.5 INTERFACE:BUFFER PROGRAM BUFFER PROGRAM BITS Buffer unit program function. Select MILLI-SECONDS or BITS. Note: To have the modem calculate the plesiochronous shift, set the buffer units to MILLISECONDS. For a specific buffer depth, set the buffer units to BITS. 3.4.5.3.6 INTERFACE:FRAMING STRUCTURE FRAMING STRUCTURE 3–40 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM T1 FRAMING STRUCTURE: G.704 E1 FRAMING STRUCTURE: G.704 Displays the currently selected framing type and structure of the data. This function is used with the buffer program in ms for plesiochronous buffer slips. Upon entry, the framing type (T1 or E1) is displayed on Line 1. The framing structure of each type (None or G.704) is displayed on Line 2. Press [←] or [→] and [↑] or [↓] to select framing structure and type. Press [ENTER] to execute the change. 3.4.5.3.7 INTERFACE:RTS TX-IF CNTRL RTS TX-IF CNTRL OFF Programs the modem to allow a Request To Send (RTS) signal to On or Off the output when data is ready for transmission. Press[←], [→], [↑], or [↓] to move the flashing cursor. Press [ENTER] to execute the change. 3.4.5.3.8 INTERFACE:TX DATA PHASE TX DATA PHASE NORMAL 3–41 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM TX data phase relationship. Use this option to select NORMAL or INVERT for the TX data relationship to the selected TX clock. Upon entry, press [↑] or [↓] to make the selection. Press [ENTER] to execute the change. 3.4.5.3.9 INTERFACE:RX DATA PHASE RX DATA PHASE NORMAL RX data phase relationship. Use this option to select NORMAL or INVERT for the RX data relationship to the selected RX clock. Upon entry, press [↑] or [↓] to make the selection. Press [ENTER] to execute the change. 3.4.5.3.10 INTERFACE:CTS DELAY CTS DELAY X SECONDS Sets the delay in seconds (0 to 60) for the Clear To Send (CTS) signal. Default: 0 Seconds. 3–42 SNM-1002 LinkSync Modem Operation 3.4.5.4 Revision 2 MN/SNM1002.OM UTILITY:SYSTEM UTILITY SYSTEM 3.4.5.4.1 SYSTEM:TIME/DATE TIME: 12:00:00AM DATE: 7/04/1976 Time of day and date display/set function. The current time and date in the modem’s memory are displayed when selected. To change the modem time and/or date, press [ENTER]. • • • 3.4.5.4.2 Press [←] or [→] to position the cursor over the parameter to be changed. Press [↑] or [↓] to change the parameter. Once the parameters are displayed as desired, press [ENTER] to set the time and date. SYSTEM:REMOTE BAUD RATE REMOTE BAUD RATE 19.200 BPS NONE The parity and baud rate settings of the modem are displayed. To change the modem parity, press [ENTER]. • Press [←] or [→] to position the cursor over the parameter to be changed. • Press [↑] or [↓] to change the parameter. • Once the parameters are displayed as desired, press [ENTER] to set the baud rate and parity. • The parity can be set to EVEN, ODD, or NONE. The baud rate is 19200 bit/s. 3–43 SNM-1002 LinkSync Modem Operation 3.4.5.4.3 Revision 2 MN/SNM1002.OM SYSTEM:REMOTE ADDRESS REMOTE ADDRESS 1 The current modem address is displayed (1 to 255). Note: 0 is reserved as a global address. To change the remote address, press [ENTER]. Press [↑] or [↓] to make the selection. Press [ENTER] to execute the change. 3.4.5.4.4 SYSTEM:REMOTE TYPE REMOTE TYPE RS-232 Select RS-485 (2-Wire), RS-485 (4-Wire), or RS-232. 3.4.5.4.5 SYSTEM:OPERATION MODE OPERATION MODE DUPLEX Programs the modem for DUPLEX, TRANSMIT ONLY, or RECEIVE ONLY operation. Upon entry, the operational status may be changed. Press [↑] or [↓] to make the selection. Press [ENTER] to execute the change. Note: When TRANSMIT ONLY or RECEIVE ONLY are selected, the appropriate faults are masked from the Faults and Stored Faults menus. 3–44 SNM-1002 LinkSync Modem Operation 3.4.5.4.6 Revision 2 MN/SNM1002.OM SYSTEM:YEAR DISPLAY YEAR DISPLAY 2 - DIGIT Selects the display for the year in either 2-digit or 4-digit format. Upon entry, the year display may be changed. Press [↑] or [↓] to make the selection. Press [ENTER] to execute the change 3.4.5.4.7 SYSTEM:TEST MODE STATUS TEST MODE STATUS --------Test mode status indicator. The following modem test points are listed and display a “+” when a test mode is active: • • • • • • • • RS CORR OFF INTRFC LOOP BACK B-BAND LOOP BACK RF LOOP BACK IF LOOP BACK CARRIER MODE RX 2047 PATTERN TX 2047 PATTERN To view the test modes, press [ENTER]. Press [↑] or [↓] to make the selection. 3.4.5.4.8 SYSTEM:LAMP TEST ?? LAMP TEST ?? PRESS ENTER Lamp test function. Press [ENTER] to turn the front panel indicators on for 3 seconds. 3–45 SNM-1002 LinkSync Modem Operation 3.4.5.4.9 Revision 2 MN/SNM1002.OM SYSTEM:SELF TEST SELF TEST AUTO Select OFF, AUTO, or RUN. After completion of the test, SELF TEST (“PASSED” or “FAILED”) is displayed. • • • 3.4.5.4.10 OFF bypasses built-in self test AUTO initiates built-in self test when turning on modem RUN initializes self test SYSTEM:DISPLAY CONTRAST DISPLAY CONTRAST LEVEL: 64 Sets the contrast setting of the Front Panel menu. Press [ENTER] to begin. Press [↑] or [↓] to increment or decrement the number at the flashing cursor, from 0 to 100. Press [ENTER] to execute the change. 3.4.5.4.11 SYSTEM:M&C FIRMWARE M&C FIRWARE FW/NNNNNN-DDR Displays the M&C module firmware version. The display includes the month, day, and year. 3.4.5.4.12 SYSTEM:BOOT FIRMWARE BOOT FIRWARE FW/NNNNNN-DDR Displays the boot module firmware version. The display includes the month, day, and year 3.4.5.4.13 SYSTEM:FPGA FIRMWARE 3–46 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM FPGA FIRWARE FW/NNNNNN-DDR Displays the FPGA module firmware version. The display includes the month, day, and year. 3.4.5.4.14 SYSTEM:DEMO MODE DEMO MODE OFF Turn all FAST features ON that are installed in the modem for 60 minutes. During this time period, the operator is encouraged to implement the features and discover the capablilites of the different options. After the 60-minute time limit, the modem resets to its previous configuration. 3.4.5.4.15 SYSTEM:EXT AGC: MAX PWR EXT AGC: MAX PWR 0.0 VOLTS Sets the AGC voltage for a receive signal level of -60.0 dBm. The voltage range is 0.0 to 10.0V, in 0.5V steps. Upon entry, the current external AGC voltage level is displayed. Press [↑] or [↓] to increment or decrement the AGC voltage level in 0.5V steps. Press [ENTER] to execute the change. Note: For any receive signal level between -25.0 and -60.0 dBm, the software will interpolate the required AGC voltage. 3.4.5.4.16 SYSTEM:EXT AGC: MIN PWR 3–47 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM EXT AGC: MIN PWR 10.0 VOLTS Sets the AGC voltage for a receive signal level of -25.0 dBm. The voltage range is 0.0 to 10.0V, in 0.5V steps. Upon entry, the current external AGC voltage level is displayed. Press [↑] or [↓] to increment or decrement the AGC voltage level in 0.5V steps. Press [ENTER] to execute the change. Note: For any receive signal level between -25.0 and -60.0 dBm, the software will interpolate the required AGC voltage. 3.4.5.4.17 SYSTEM:MASTER RESET MASTER RESET HARD/SOFT Initiating a hard reset will reset the modem and place the default configuration settings in ROM. Initiating a soft reset will reset the modem hardware, but saves the current configuration settings. CAUTION Select [ENTER] once to access HARD or SOFT. Press [←] or [→] to make the selection. Press [ENTER]. Press [→] five times to move the cursor to YES. Select YES and press [ENTER] again. Note: The following parameters do not revert to default settings after a hard reset: • • • • • • • 3.4.5.5 Address Parity Baud Rate Remote Type Ext AGC: Min Pwr Ext AGC: Max Pwr Display Contrast UTILITY:MODEM TYPE 3–48 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM UTILITY MODEM TYPE 3.4.5.5.1 MODEM TYPE:MODEM TYPE MODEM TYPE CUSTOM Selects the following types of modem operation: • • CUSTOM EFD Selections are made from the Front Panel menu Closed Network Operation When the modem is changed from one type of operation to another, the modem will be reset to the default configurations of the new modem type. The RF-IF Output must be turned on to get the modem to lock. • • • • If the existing modem type is the same as the type entered, the modem will not change any parameters. If the modem type is changed to Custom, no parameters will be changed. If the modem will not allow the modem type selection, that type of operation may not be an available option. Select MODEM OPTIONS and OVERHEAD OPTIONS to see which modem operations are allowed. 3–49 SNM-1002 LinkSync Modem Operation 3.4.5.5.2 Revision 2 MN/SNM1002.OM MODEM TYPE:MODEM EMULATION MODEM EMULATION DISABLED Selects the following types of modem emulation: SDM-100 SDM-300 SDM-308-4 SDM-308-4 SDM-308-4 SDM-308-4 SDM-309 SDM-650 SDM-650 SDM-6000 VER: 15.7.1 6.2.2 4.03 6.05 6.08 7.03 6.04 4.12A 4.16 5.1.1 or Disabled Upon entry, the current modem emulation is displayed. Press [↑] or [↓] to change the display. Press [ENTER] to execute the change. 3.4.5.5.3 MODEM TYPE:REVISION EMULATION REV EMULATION CURRENT VERSION Programs an emulation mode of a previous functional revision. This allows the user to select the CURRENT VERSION or FUNCTIONAL X. Note: The number displayed in the CURRENT VERSION position increases with each software version change. Upon entry, the CURRENT VERSION is displayed. Press [↑] or [↓] to select the FUNCTIONAL version. Press [ENTER] to execute the change. 3–50 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM Notes: 1. Programming a current version (default) allows all features and options (if installed) to operate normally. 2. Programming a FUNCTIONAL version (X) eliminates any changes that affect the later version. Only functional changes are affected by the revision emulation feature. 3. A correction change (e.g., VER 3.1.2) remains fixed in accordance with the latest version. Since the revision emulation default is the current version, program the functional version at the start of each operation. 4. The revision emulation feature does not affect some interface changes for the direct operation of the modem (Configuration save/recall, test mode screen in the Utility/System, all factory setup modes, etc.). 3.4.5.5.4 MODEM TYPE:MODEM OPTIONS MODEM OPTIONS -------------- Displays the installed modem options. If the option is installed, a “+” symbol is displayed. To view the available options press [ENTER]. Observe for the flashing cursor. Press the [←] [→] arrows to move from one symbol to the next. The first line will display the option. The second line will display the status: HIGH POWER HIGH STABILITY ASLT VITERBI SEQUENTIAL SINGLE RATE LOW RATE VAR FULL RATE VAR CARD #1 PCB CARD #2 PCB CARD #3 PCB 8PSK 2/3 TX ONLY RX ONLY (0) (0) (-) (+) (-) (-) (-) (+) (x) (x) (x) (-) (-) (-) 3–51 0 = Not Installed, Not Upgradeable - = Not Installed + = Installed X = Not Installed, Field Upgradeable SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM 3.4.5.5.5 MODEM TYPE:CARD #1 TYPE (NOT INSTALLED) 3.4.5.5.6 MODEM TYPE:CARD #2 TYPE (NOT INSTALLED) 3.4.5.5.7 MODEM TYPE:CARD #3 TYPE (NOT INSTALLED) 3.4.5.5.8 MODEM TYPE:LOCAL MODEM AUPC LOCAL MODEM AUPC OFF Configures the modem for the self-monitoring Local Modem AUPC mode and for local TX power control (self-monitoring) due to severe rain fade. Notes: 1. The self-monitoring Local Modem AUPC mode is not used when the ASYNC/AUPC is selected as the Modem Type. 2. Used for local control (self-monitoring) due to severe rain fade. 3.4.5.5.9 MODEM TYPE:MODEM SERIAL MODEM SERIAL 123456789 Status Only 3–52 SNM-1002 LinkSync Modem Operation 3.4.5.5.10 Revision 2 MN/SNM1002.OM MODEM TYPE:CONFIGURATION CODE - MODEM CONFIGURATION CODE - MODEM 1) AAAAAAAAAA 2) AAAAAAAAAA If installed, Status Only Comtech EF Data supplied code. . 3.4.5.6 UTILITY:FACTORY SETUP (NOT APPLICABLE) 3–53 SNM-1002 LinkSync Modem Operation Revision 2 MN/SNM1002.OM This page is intentionally left blank. 3–54 Chapter 4. THEORY OF OPERATION 4.1 LinkSync™ LinkSync™ is a unique MIDAS feature providing: • Automatic Frequency Control (AFC) • Uplink Power Control (UPC) at the MIDAS Controller • Circuit Power Management (Option) ! Site level call blocking based on HPA power 4.1.1 Automatic Frequency Control MIDAS provides automatic frequency control (AFC) to reduce the traffic modem acquisition time for continuous mode operation and to improve the burst acquisition performance of the SNM-1000/1001 Network Control Modem and the Node Control Modems1, by keeping the frequency drift to within ± 500 Hz. The outbound control channel is used as the system-wide reference, which is continuously monitored by the LinkSync™ Modem at the MIDAS Controller site and all the Node Control Modems2. The AFC process does not depend on the absolute accuracy in any part of the system. 1 Includes SNM-1000 and the integrated traffic/control modems (SNM-1010 and SNM-1010L). 2 The integrated traffic/control modems and the network terminals in a standard configuration monitor the outbound control channel in the “control mode”. 4–1 SNM-1002 LinkSync Modem Theory of Operation Revision 2 MN/SNM1002.OM The AFC process consists of three steps: 1. Removing the receive offset of the Network Control Modem at the MIDAS Controller. 2. Removing the receive offset of the Node Control Modems and the traffic modems at the traffic sites. 2. Removing the transmit offset of the Node Control Modems and the traffic modems at the traffic sites. These three steps are performed as follows: 1. The LinkSync™ Modem measures the receive frequency of the outbound control channel and provides this information to the MIDAS Controller periodically, the period being user-configurable. The MIDAS Controller then calculates the offset from the nominal, which is used to correct the Network Control Modem’s TX frequency. 2. The Node Control Modem determines the receive offset by measuring the receive frequency of the outbound control channel. a. This offset is used to calibrate the RX frequency of the Node Control Modem and all the traffic modems (during call setup) at the node. b. The traffic modems that have active calls are not adjusted. Calibrations are periodically performed where the period is user –configurable. 3. MIDAS Controller periodically polls a Node Control Modem to transmit exclusively, and measures the receive frequency for the incoming bursts from the Node Control Modem on the inbound control channel. a. It then estimates the offset and provides this information to the Node Control Modem. b. The Node Control Modem then applies this offset to correct its TX frequency and that of all the traffic modems (during call setup). c. The traffic modems that have active calls are not adjusted. This process is repeated periodically, the period being user-configurable. 4–2 SNM-1002 LinkSync Modem Theory of Operation 4.1.2 Revision 2 MN/SNM1002.OM Uplink Power Control Uplink Power Control at the MIDAS Controller site compensates for outbound control channel uplink degradation so that it always downlinks at a constant power at the satellite. A reference Eb/No is calculated for the received outbound control channel at the MIDAS Controller site for clear sky conditions. The LinkSync™ Modem, at the MIDAS Controller site, measures the received outbound control channel Eb/No on a continuous basis. 4.1.3 • If the measured Eb/No differs from the calculated reference, the MIDAS Controller calculates the offset to be applied to the transmit power level of the outbound control channel to achieve the desired reference Eb/No. • The transmit power is adjusted only when the difference exceeds a threshold, which is configurable. Circuit Power Management (Option) Circuit power management is provided as an option. It includes: • • 4.1.3.1 Circuits at setup. Site level call blocking based on available High power Amplifiers (HPA) power. Site Level Call Blocking The MIDAS Controller supports dynamic site level call blocking based on the available HPA power. The MIDAS Controller keeps track of the HPA power for each site. A call originating from a site is blocked if it would cause the total transmit power for that site to exceed the recommended HPA power (less backoff). This leads to improved system stability. 4.2 Monitor and Control (M&C) The M&C monitors the modem and provides configuration updates to other modems within the modem when necessary. The modem configuration parameters are maintained in battery-backed RAM, which provides total recovery after power-down situation. The M&C functions include extensive fault and status reporting. All modem functions are accessible through a remote communications interface. A block diagram of the M&C is shown in Figure 4-1. 4–3 SNM-1002 LinkSync Modem Theory of Operation 4.2.1 Revision 2 MN/SNM1002.OM Theory of Operation The M&C card is composed of the following subsections: • • • • • • • • Microcontroller with Universal Asynchronous Receiver/Transmitter (UART) Digital-to-Analog Converter (DAC) Read Only Memory (ROM) Analog-to-Digital Converter (ADC) Read Access Memory (RAM) Universal ASYNC User Interface Fault and Alarm Relays FAULT AND ALARM RELAYS MODEM 11 MHz CLOCK ROM (M&C, BULK, BOOT) 2 DAC I C BUS MICROCONTROLLER RAM AND REAL TIME CLOCK ADC EIA-232 OR EIA-485 9-PIN REMOTE Figure 4-1. M&C Block Diagram 4–4 SNM-1002 LinkSync Modem Theory of Operation Revision 2 MN/SNM1002.OM The heart of the M&C card is the Dallas 80C310 microcontroller operating at 11 MHz. This microcontroller contains 256 kbytes of internal RAM. The ROM at U8 is 29F040 (512 kbytes). ROM access times must be equal to or greater than 150 ns. The RAM can be 8 or 32 kbytes in size. This RAM chip is internally battery-backed and contains a real time clock used by the M&C. The non-volatile RAM on the M&C module allows the module to retain configuration information without prime power for 1 year (approximately). If the modem is powered down, the following sequence is carried out by the M&C microcontroller. 1. When power is applied to the M&C, the microcontroller checks the non-volatile memory to see if valid data has been retained. If valid data has been retained, the modem is reconfigured to the parameters maintained by the RAM. 2. If the non-volatile memory fails the valid data test, a default configuration from ROM is loaded into the system. The UART supports serial ASYNC communications channels (remote port) with a data rate of 19200 bit/s. The UART is a built-in peripheral of the microcontroller. The communications type is EIA-232. The DAC supplies a voltage that controls the contrast of the display. The ADC monitors all the voltages from the power supply. The DAC and ADC are mapped to the microcontroller with an Integrated Circuit (IC) bus. All functions are memory-mapped to the micro-controller. 4.3 Modulator The modulator provides PSK modulated carriers within the 50 to 180 MHz range. The types of modulation that encode the transmitted baseband data from the interface PCB are: • • BPSK QPSK Refer to Section 4.2.3 for a description of each modulation type. A block diagram of the modulator is shown in Figure 4-2. 4–5 SNM-1002 LinkSync Modem Theory of Operation Revision 2 MN/SNM1002.OM SCT PLL OPTIONAL SCT MONITOR & CONTROL CONVOLUTIONAL ENCODER REFERENCE LO BPF DIGITAL SIGNAL PROCESSING BPF POWER LEVEL CONTROL LPF RF OUTPUT RF LOOPBACK OUTPUT Figure 4-2. Modulator Block Diagram 4–6 SNM-1002 LinkSync Modem Theory of Operation 4.3.1 Revision 2 MN/SNM1002.OM Modulator Specifications Refer to Table 4-1 for modulator specifications. Table 4-1. Modulator Specifications Parameter Modulation Types Data Rate Range Symbol Rate Range Test Modes Frequency Range Frequency Select Method Frequency Step Size Frequency Stability Phase Error Filtering Type Spectral Occupancy Spurious and Harmonics Output Power Level Range Output Stability Output Power Adjustment Output Impedance Output Return Loss Scrambler Type Differential Encoding FEC Convolution Encoding/ Viterbi or Sequential Encoding Filter Masks I/O Connector Reported Faults Specification BPSK QPSK 2.4 kbit/s to 1.25 Mbit/s 1/2 Rate BPSK 4.8 kbit/s to 2.5 Mbit/s 1/2 Rate QPSK 7.2 kbit/s to 3.75 Mbit/s 3/4 Rate QPSK 8.4 kbit/s to 4.375 Mbit/s 7/8 Rate QPSK 4.8 ks/s to 2.5 Ms/s Carrier Null and Quadrature (Dual and Offset) 50 to 180 MHz Synthesized 1 Hz ± 10 PPM oscillator 2.5° maximum Nyquist, pre-equalized Spectral density is -30 dB at ± 0.75 symbol rate -55 dBc, 0 to 500 MHz -5 to -30 dBm, ± 0.5 dB ± 0.5 dB 0.1 dB step size 75Ω 20 dB minimum INTELSAT V.35 2-phase or none Rate 1/2, 3/4, 7/8 EFD Closed BNC 75Ω (TX IF) AGC Level IF Synthesizer I Channel Filter Activity Q Channel Filter Activity Modem Reference Activity Data Clock Syn Module Modem Reference PLL 4–7 SNM-1002 LinkSync Modem Theory of Operation 4.3.2 Revision 2 MN/SNM1002.OM Theory of Operation The modulator is composed of eight basic subsections. These subsections are divided into the baseband processing section and the RF section of the modulator. The modulator controls all programmable functions on this module. Fault information from the modulator is sent to the M&C. Refer to Chapter 5 for a list of reported faults. The major modulator subsections are: • • • • • • • • Scrambler/Differential Encoder Convolutional Encoder Programmable Vector Rotation I/Q Nyquist Filters Modulator RF Synthesizer Output Amplifier Output Level Control The data is sent to the scrambler for energy dispersal, and then to the differential encoder. The differential encoder is a 2-bit encoder which allows for resolution of two of the four ambiguity states of the QPSK demodulator. The data is sent to the convolutional encoder for encoding the baseband data. The code rates 1/2, 3/4, and 7/8 are based on the symbol rate range of 2.4 kbit/s to 2.5 Mbit/s. For Viterbi codes, the convolutional encoder encodes the data at 1/2 rate. If the selected code rate is 3/4, then 2 of every 6 symbols are punctured. For 3 bits in, there are 4 symbols out. After the convolutional encoder, the data is sent to a programmable vector rotation circuit. This feature provides the user with data communications compatibility for spectrum reversal of the I and Q channels before and after satellite transmission. The I and Q channel data then pass through a set of variable rate digital Nyquist filters. 4–8 SNM-1002 LinkSync Modem Theory of Operation Revision 2 MN/SNM1002.OM The two identical digital Nyquist filters are followed by Direct Digital Modulation. Symbol rates up to 2.5 Mbit/s can be achieved automatically. The modulated carrier is applied to the RF section for conversion to the correct output frequency. The spectral shape will be identical to that of the input data streams, but double-sided about the carrier frequency. The RF synthesizer provides the proper frequencies to convert the modulator IF to the desired output frequency in the 50 to 180 MHz range. The synthesizer has a single loop, and incorporates a Direct Digital Synthesis (DDS) chip to accommodate 1 Hz steps over a range of 130 MHz. The RF section has a frequency stability of ± 1 x 10-5. An optional 2 x 10-7 Temperature Compensated Crystal Oscillator (TCXO) can be installed. The signal is sent to the output amplifier. The amplifier takes the low level signal from the modulator section and amplifies the signal to the proper level for output from the module. The amplifier circuitry provides programmable control of the output level over a range of -5 to -30 dB, in 0.1 dB steps. The amplifier has power leveling of ± 0.5 dB to maintain the stability of the output level over time and temperature. 4.3.3 Theory of Modulation Types The modulation types for the modem include BPSK or QPSK. The PSK data transmission encoding method uses the phase modulation technique. This method varies the phase angle of the carrier wave to represent a different bit value for the receiver. The higher levels of modulation are required for an operating range that has a limited bandwidth. The order of modulation is represented by mPSK, where “m” relates to the number of discrete phase angles. Refer to the following list for a brief description of the modulation types. • • BPSK: 2 discrete phase angles represent the 2 possible states of a symbol. QPSK: 4 discrete phase angles represent the 4 possible states of a symbol. Note: The code rate determines the number of symbols per bit. 4–9 SNM-1002 LinkSync Modem Theory of Operation 4.3.3.1 Revision 2 MN/SNM1002.OM BPSK Encoding The modulator converts transmitted baseband data into a modulated BPSK carrier at 2.4 kbit/s to 1.25 Mbit/s (1/2 rate). Using vector analysis of the constellation pattern, BPSK represents one symbol with the carrier phase either at 0° or 180°. The 1/2 rate encoding at the convolutional encoder provides two symbols output for every bit input. Code Rate 1/2 4.3.3.2 Symbols/Bit 2 Bits/Hz 0.5 QPSK Encoding The modulator converts transmitted baseband data into a modulated QPSK carrier at the following parameters: • • • 4.8 kbit/s to 2.5 Mbit/s (1/2 rate) 7.2 kbit/s to 3.75 Mbit/s (3/4 rate) 8.4 kbit/s to 4.375 Mbit/s (7/8 rate) Using vector analysis of the constellation pattern, QPSK represents a symbol with the carrier phase angle at 45°, 135°, 225°, or 315°. The 1/2, 3/4, and 7/8 rates encoded at the convolutional encoder provide the desired input/output bit rates. Code Rate 1/2 3/4 7/8 Symbols/Bit 2 1.5 1.143 4–10 Bits/Hz 1 1.33 1.75 SNM-1002 LinkSync Modem Theory of Operation 4.4 Revision 2 MN/SNM1002.OM Demodulator A block diagram of the demodulator is shown in Figure 4-3. The demodulator converts PSK modulated carriers within the 50 to 180 MHz range to a demodulated baseband data stream. The converted modulation types are BPSK and QPSK (refer to Section 4.2.3 for a description of modulation types). The demodulator then performs FEC on the data stream using Viterbi decoding algorithms. LOOPBACK RF INPUT SWITCH AGC LPF BPF BPF RF INPUT 50 TO 180 MHz LO #1 REF VCXO OC XO OPT HIGH STABILITY A TO D CONVERTER LO #2 REFERENCE REF PLL DIGITAL SIGNAL PROCESSING VITERBI DECODER DIGITAL CLOCK RECOVERYLOOP EXT REFERENCE DOPPLER/ PLESIOCHRONOUS BUFFER Figure 4-3. Demodulator Block Diagram 4–11 INTERFACE SNM-1002 LinkSync Modem Theory of Operation 4.4.1 Revision 2 MN/SNM1002.OM Demodulator Specifications Refer to Table 4-2 for demodulator specification. Table 4-2. Demodulator Specification Parameter Demodulation Types Data Rate Range Symbol Rate Range IF Frequency Input Level Decoding Type Filter Masks Descrambler Type Reported Faults Specification BPSK, QPSK 2.4 kbit/s to 1.25 Mbit/s 4.8 kbit/s to 2.5 Mbit/s 7.2 kbit/s to 3.75 Mbit/s 8.4 kbit/s to 4.375 Mbit/s 4.8 ks/s to 2.5 Ms/s 50 to 180 MHz, in 1 Hz steps -30 to -55 dBm Viterbi: 1/2, 3/4, 7/8 EFD Closed net V.35 Carrier Detect IF Synthesizer BER Threshold RX Clock Syn Module I Channel Q Channel 4–12 1/2 Rate BPSK 1/2 Rate QPSK 3/4 Rate QPSK 7/8 Rate QPSK SNM-1002 LinkSync Modem Theory of Operation 4.4.2 Revision 2 MN/SNM1002.OM Theory of Operation The demodulator functions as an advanced, digital, coherent-phase-lock receiver and decoder. Demodulator faults are also reported to the front panel. The demodulator consists of the following basic subsections. • • • • • • • • • • Digital Costas Loop RF Section Automatic Gain Control Analog-to-Digital (A/D) Converter Soft Decision Mapping Programmable Vector Rotation Digital Nyquist Filters FEC Decoder Digital Clock Recovery Loop Decoder The modulated IF signal at 50 to 180 MHz enters the RF module for conversion to an IF frequency. The IF is then sampled by an A to D converter and digitally demodulated. The I and Q data is then sent to the digital Nyquist filters, resulting in a filtered, digital representation of the received signal. The digital data is then sent to four separate circuits: • • • • Automatic Gain Control Carrier Recovery (Costas) Loop Clock Recovery Loop Soft Decision Mapping The AGC provides a gain feedback signal to the RF section. This closed loop control ensures that the digital representation of the I and Q channels is optimized for the Costas and Clock loops, as well as the soft-decision mapping circuitry. When the active decoder determines that the modem is locked, the M&C stops the sweep and begins the de-stress process. This involves fine tuning the DDS based on the phase error in the Costas loop. The de-stress process continues as long as the modem is locked. If the carrier is interrupted, the M&C resumes the sweep process. The digital Costas loop, in conjunction with a Direct Digital Synthesizer (DDS), performs the carrier recovery function. The Costas loop consists of a Costas phase detector, loop filter, and DDS, all implemented digitally. The DDS performs the function of a Voltage-Controlled Oscillator (VCO) in an analog implementation, but can be easily programmed to the desired center frequency via the M&C. The output of the DDS is sent to the RF module and provides the reference to which the local oscillator is locked. The M&C sweeps the local oscillator (via DDS programming) through the user-specified sweep range. The digital clock loop, in conjunction with another DDS, performs the clock recovery function. The clock loop consists of a phase detector, loop filter, and DDS, all 4–13 SNM-1002 LinkSync Modem Theory of Operation Revision 2 MN/SNM1002.OM implemented digitally. The DDS performs the function of a VCO in an analog implementation. The recovered data and symbol clocks are then used throughout the demodulator. The soft decision mapper converts the digital I and Q data to 3-bit soft decision values. These values are then fed to the programmable vector rotation circuit, providing compatibility with spectrum reversal of the I and Q channels. The output of the vector rotation circuit is then sent to the Viterbi decoder. 4–14 Chapter 5. MAINTENANCE This chapter provides the following information: • • • 5.1 System checkout Fault isolation Module replacement and identification System Checkout CAUTION This equipment contains parts and assemblies sensitive to damage by ESD. Use ESD precautionary procedures when touching, removing, or inserting PCBs. The modem comes equipped with an internal self-test feature. This feature is designed to provide the operator with maximum confidence that the modem is fully operational without installing external equipment. A 2047 pattern is generated by the modem and routed through all sections. This is accomplished by placing the modem in IF and baseband loopbacks. Pseudo Gaussian noise is introduced to the modulated IF section allowing the modem to check its indicated Eb/N0 against the known Eb/N0 of the demodulated input. Observe the following: • If this measurement falls outside of a specified window, the modem declares a failed test. • Faults, if any, are stored in the Stored Fault menu. 5–1 SNM-1002 LinkSync Modem Maintenance 5.1.1 Revision 2 MN/SNM1002.OM Interface Checkout Use the following procedure and the test setup in Figure 5-1 to inspect the interface. Figure 5-1. Fault Isolation Test Setup 1. Connect a BER test set to the appropriate modem data connector as shown in Figure 5-1. Refer to Chapter 2 for external modem connections. 2. Set up the modem for baseband loopback operation by using the directions provided in section A.3.3. The modem will run error free. 3. Change the modem from baseband loopback to interface loopback operation by using the directions provided in section A.3.3. The modem will run error free. 5–2 SNM-1002 LinkSync Modem Maintenance 5.1.2 Revision 2 MN/SNM1002.OM Modulator Checkout Use the following procedure to check out the modulator: 1. Set up the equipment as shown in Figure 5-1. Refer to Chapter 4 for modulator specifications. 2. Set up the modem for operation by using the directions provided in section A.3. 3. Clear all TX faults by correct use of data and clock selection (Chapter 4). 4. Measure the Eb/N0 with a receiver that is known to be operating properly. Refer to Table 5-1 and Figure 5-2 to check for proper Eb/N0 level. The (S+N)/N is measured by taking the average level of the noise and the average level of the modem spectrum top. Use this measurement for the first column on Table 5-1. Read across the page to find the S/N and Eb/N0 for the specific code rate. Once the demodulator has locked to the incoming signal, the terminal will display signal level, raw BER, corrected BER, and Eb/N0. Refer to Chapter 1 for examples of BER performance curves. 5. Connect a spectrum analyzer to the modem as shown in Figure 5-1. Ensure the IF output meets the appropriate mask and spurious specifications. Measure the power output at different levels and frequencies. A typical output spectrum is shown in Figure 5-3. 6. To check the frequency and phase modulation accuracy: a. Set the modem to the continuous wave Normal mode by using the directions in section A.3.1. This sets the Carrier mode in the off condition. A pure carrier should now be present at the IF output. This should only be used for frequency measurements. In this mode, spurious and power measurements will be inaccurate. b. Set the modem to the continuous wave Offset mode by using directions in section A.3.1. This generates a single, upper side band suppressed carrier signal. Ensure the carrier and side-band suppression is < 35 dBc. 5–3 SNM-1002 LinkSync Modem Maintenance Revision 2 MN/SNM1002.OM Table 5-1. Conversion to S/N and Eb/N0 Chart (dB) (S+N)/N 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5 9.0 9.5 10.0 10.5 11.0 11.5 12.0 12.5 13.0 13.5 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5 18.0 18.5 19.0 19.5 20.0 Code S/N 1.8 2.6 3.3 4.1 4.7 5.4 6.0 6.6 7.3 7.8 8.4 9.0 9.5 10.1 10.6 11.2 11.7 12.2 12.8 13.3 13.8 14.3 14.9 15.4 15.9 16.4 16.9 17.4 17.9 18.4 18.9 19.5 20.0 Rate 1/2 Eb/N0 1.8 2.6 3.3 4.1 4.7 5.4 6.0 6.6 7.3 7.8 8.4 9.0 9.5 10.1 10.6 11.2 11.7 12.2 12.8 13.3 13.8 14.3 14.9 15.4 15.9 16.4 16.9 17.4 17.9 18.4 18.9 19.5 20.0 Code S/N 1.8 2.6 3.3 4.1 4.7 5.4 6.0 6.6 7.3 7.8 8.4 9.0 9.5 10.1 10.6 11.2 11.7 12.2 12.8 13.3 13.8 14.3 14.9 15.4 15.9 16.4 16.9 17.4 17.9 18.4 18.9 19.5 20.0 5–4 Rate 3/4 Eb/N0 0.0 0.8 1.6 2.3 3.0 3.6 4.3 4.9 5.5 6.1 6.7 7.2 7.8 8.3 8.9 9.4 10.0 10.5 11.0 11.5 12.1 12.6 13.1 13.6 14.1 14.6 15.2 15.7 16.2 16.7 17.2 17.7 18.2 Code S/N 1.8 2.6 3.3 4.1 4.7 5.4 6.0 6.6 7.3 7.8 8.4 9.0 9.5 10.1 10.6 11.2 11.7 12.2 12.8 13.3 13.8 14.3 14.9 15.4 15.9 16.4 16.9 17.4 17.9 18.4 18.9 19.5 20.0 Rate 7/8 Eb/N0 -0.6 0.2 0.9 1.6 2.3 3.0 3.6 4.2 4.8 5.4 6.0 6.6 7.1 7.7 8.2 8.8 9.3 9.8 10.3 10.9 11.4 11.9 12.4 12.9 13.5 14.0 14.5 15.0 15.5 16.0 16.5 17.0 17.5 SNM-1002 LinkSync Modem Maintenance Revision 2 MN/SNM1002.OM RL -49.00 dBm ATTEN 10 dB 2.00 dB/DIV RES BANDWIDTH 10.0 kHz Modem Rate = 2144 kbit/s, 3/4 Rate Coding with 7.7 dB Eb/No (S + N)/N = 10 dB CENTER 70.000 MHz *RB 10.0 kHz *VB 10.0 Hz SPAN 1.000 MHz ST 30.00 sec Figure 5-2. Typical Output Spectrum (with Noise) RL -20.29 dBm ATTEN 10 dB 5.00 dB/DIV PASS CENTER FREQUENCY 140.000 MHz CENTER 140.000 MHz *RB 30.0 kHz *VB 3.00 Hz SPAN 5.000 MHz ST 166.7 sec Figure 5-3. Typical Output Spectrum (without Noise) 5–5 SNM-1002 LinkSync Modem Maintenance 5.1.3 Revision 2 MN/SNM1002.OM Demodulator Checkout Use the following procedure to test the demodulator. 1. Set up the equipment as shown in Figure 5-1. Refer to Chapter 4 for the demodulator specifications. 2. Set up the modem with an external IF loop and level. Use a properly operating modulator, and ensure that power levels, data rates, code rates, etc., are compatible. 3. Allow the modem to lock up. Depending on the data rate and overhead type, lock up may take several seconds. When the green carrier detect LED is on and the DEMUX lock fault has been cleared (where applicable), the modem will run at the specified error rate. Run the TX power level (input amplitude) over the full range, and offset the TX frequency from the RX frequency by 35 kHz. Ensure the modem still runs within the specified error rate. 4. Set up the modem to check the constellation patterns with an oscilloscope that is set in the X-Y mode. Typical constellation patterns with noise and without noise are shown in Figure 5-4. These test points are available on the auxiliary connector (J9, pins 6 and 8). It is not necessary to open the modem to look at these test points. 5–6 SNM-1002 LinkSync Modem Maintenance Revision 2 MN/SNM1002.OM WITH NOISE WITHOUT NOISE Figure 5-4. Typical Eye Constellations 5–7 SNM-1002 LinkSync Modem Maintenance 5.2 Revision 2 MN/SNM1002.OM Fault Isolation The modem’s design allows a technician to repair a faulty modem on location. CAUTION This equipment contains parts and assemblies sensitive to damage by ESD. Use ESD precautionary procedures when touching, removing, or inserting PCBs. The fault isolation procedure lists the following categories of faults or alarms. • • • • • • Modulator Demodulator Transmit Interface Receive Interface Common Equipment Backward Alarms Note: Each fault or alarm category includes possible problems and the appropriate action required to repair the modem. If any of the troubleshooting procedures mentioned earlier in this chapter do not isolate the problem, and Comtech EFData Customer Support assistance is necessary, have the following information available for the representative: 5.2.1 • Modem configuration. Modem configuration includes the modulator, demodulator, interface, or local AUPC sections. • Faults (active or stored). System Faults/Alarms System faults are reported in the “Faults/Alarms” menu, and stored faults are reported in the “Stored Flts/Alms” menu. Refer to Appendix A for more information. To determine the appropriate action for repairing the modem, refer to Table 5-2 and the list of possible problems. 5–8 SNM-1002 LinkSync Modem Maintenance Revision 2 MN/SNM1002.OM * ** X X X X X X X X X X X Legend Note Fault/Alarm Relay Test Points Connector/Pins 1 TX FAULT Pin 4 (NO), 5 (COM), 6 (NC) * 2 RX FAULT Pin 7 (NO), 8 (COM), 9 (NC) * 3 COM EQ FAULT Pin 1 (NO), 2 (COM), 3 (NC) * 4 TX ALARM #2 Pin 4 (NO), 5 (COM), 6 (NC) * 5 RX ALARM #3 Pin 7 (NO), 8 (COM), 9 (NC) * 6 PRIMARY ALARM Pin 43 (NO), 10 (COM), 27 (NC) * 7 SECONDARY ALARM Pin 44 (NO), 11 (COM), 28 (NC) * 8 DEF MAINT ALARM Pin 17 ** A connection between the common and N.O. contacts indicate no fault/alarm. Signal is open collector high impedance if faulted. 5–9 SECONDARY ALARM RELAY DEFERRED MAIN ALARM SPARE ALARM RELAY #1 RX ALARM RELAY #3 (5) PRIMARY ALARM RELAY (4) X X X X X RX ALARM LED X X X (3) TX ALARM RELAY #2 X X X TX ALARM LED X X X (2) COM EQ FAULT RELAY (1) X X X X X COM EQ FAULT LED X X X X X RX FAULT RELAY X X X X X RX FAULT LED TX FAULT RELAY IF SYNTHESIZER DATA CLOCK SYN I CHANNEL Q CHANNEL AGC MODEM REF ACT MODEM REF PLL MODULE CONFIGURATION DEMODULATOR FAULTS CARRIER DETECT IF SYNTHESIZER I CHANNEL Q CHANNEL BER THRESHOLD MODULE CONFIGURATION TX FAULT LED MODULATOR FAULTS TX IF OUTPUT OFF Table 5-2. SNM-1002 Fault Tree (6) (7) (8) SNM-1002 LinkSync Modem Maintenance Revision 2 MN/SNM1002.OM TX DROP TX DATA/AIS TX CLK PLL TX CLK ACTIVITY TX AUDIO 1 CLIP TX AUDIO 2 CLIP CONFIGURATION RX INTERFACE FAULTS BUFFER UNDERFLOW BUFFER OVERFLOW RX DATA/AIS FRAME BER BACKWARD ALARM BUFFER CLK PLL BUFFER CLK ACT DEMUX LOCK RX 2047 LOCK BUFFER FULL RX INSERT RX AUDIO 1 CLIP RX AUDIO 2 CLIP CONFIGURATION X X X X X X SPARE RELAY ALARM #1 (5) X Not Applicable Not Applicable X X X X X X X X X X X X X X X Not Applicable Not Applicable X X X X Not Applicable Not Applicable Not Applicable X X Legend Test Note Fault/Alarm Relay Test Points Connector/Pins 1 TX FAULT Pin 4 (NO), 5 (COM), 6 (NC) * 2 RX FAULT Pin 7 (NO), 8 (COM), 9 (NC) * 3 COM EQ FAULT Pin 1 (NO), 2 (COM), 3 (NC) * 4 TX ALARM #2 Pin 4 (NO), 5 (COM), 6 (NC) * 5 RX ALARM #3 Pin 7 (NO), 8 (COM), 9 (NC) * 6 PRIMARY ALARM Pin 43 (NO), 10 (COM), 27 (NC) * 7 SECONDARY ALARM Pin 44 (NO), 11 (COM), 28 (NC) * 8 DEF MAINT ALARM Pin 17 ** * A connection between the common and N.O. contacts indicate no fault/alarm. ** Signal is open collector high impedance if faulted. 5–10 DEFERRED MAIN ALARM (4) RX ALARM RELAY #3 RX ALARM LED TX ALARM RELAY #2 TX ALARM LED COM EQ FAULT LED COM EQ FAULT RELAY (3) SECONDARY ALARM RELAY (2) PRIMARY ALARM RELAY (1) Not Applicable RX FAULT RELAY RX FAULT LED TX FAULT RELAY TX FAULT LED TX INTERFACE FAULTS TX IF OUTPUT OFF Table 5-2. SNM-1002 Fault Tree (Continued) (6) (7) (8) SNM-1002 LinkSync Modem Maintenance Revision 2 MN/SNM1002.OM (5) X X X X X Legend Test Note Fault/Alarm Relay Test Points Connector/Pins 1 TX FAULT Pin 4 (NO), 5 (COM), 6 (NC) * 2 RX FAULT Pin 7 (NO), 8 (COM), 9 (NC) * 3 COM EQ FAULT Pin 1 (NO), 2 (COM), 3 (NC) * 4 TX ALARM #2 Pin 4 (NO), 5 (COM), 6 (NC) * 5 RX ALARM #3 Pin 7 (NO), 8 (COM), 9 (NC) * 6 PRIMARY ALARM Pin 43 (NO), 10 (COM), 27 (NC) * 7 SECONDARY ALARM Pin 44 (NO), 11 (COM), 28 (NC) * 8 DEF MAINT ALARM Pin 17 ** * A connection between the common and N.O. contacts indicate no fault/alarm. ** Signal is open collector high impedance if faulted. 5–11 DEFERRED MAIN ALARM SPARE ALARM RELAY #1 RX ALARM RELAY #3 RX ALARM LED TX ALARM RELAY #2 (4) SECONDARY ALARM RELAY (3) X X X X X X X TX ALARM LED COM EQ FAULT RELAY COM EQ FAULT LED RX FAULT RELAY (2) BATTERY/CLOCK -12V POWER SUPPLY +12V POWER SUPPLY +5V SUPPLY SELF TEST CONTROLLER INTERFACE MODULE PRIMARY ALARM RELAY (1) RX FAULT LED TX FAULT RELAY TX FAULT LED COMMON EQUIP FAULTS TX IF OUTPUT OFF Table 5-2. SNM-1002 Fault Tree (Continued) (6) (7) (8) SNM-1002 LinkSync Modem Maintenance 5.2.2 Revision 2 MN/SNM1002.OM Faults/Alarms Display General fault, status, and alarm information are indicated by 10 LEDs located on the modem’s front panel. A fault (red LED) indicates a fault that currently exists in the modem. When a fault occurs, it is stored in the stored fault memory, and indicated by the single yellow LED. The LED is turned off when the fault clears. If the fault clears, the occurrence is also stored. A total of 10 occurrences of any fault can be stored. Each fault or stored fault indicated by a front panel LED could be one of many faults. To determine which fault has occurred, use the directions in Appendix A. Alarms are considered minor faults which will not switch the modem offline in a redundant system. Alarms are shown by following the direction in section A.4. 5.2.3 Faults/Alarms Analysis This section describes the possible problems and actions to take for the following faults: • • • • • • Modulator Demodulator Transmit interface Receive interface Common equipment Backward alarm 5–12 SNM-1002 LinkSync Modem Maintenance 5.2.3.1 Revision 2 MN/SNM1002.OM Modulator Faults Fault/Alarm IF SYNTHESIZER Possible Problem and Action Modulator IF synthesizer fault. DATA CLOCK SYN This is considered a major alarm, and will turn off the modulator output. Return the modem for repair. Transmit data clock synthesizer fault. I CHANNEL This fault indicates that the internal clock VCO has not locked to the incoming data clock, or the internal clock synthesizer has not locked to the internal reference. This is considered a major alarm, and will turn off the modulator output. Ensure the proper data rate has been set up and selected, and the incoming data rate matches the modem selections Use interface loopback for isolating the problem. Verify the frequency of the input data clock to be within the lock range of 100 PPM. Activity alarm for the I channel digital filter. Q CHANNEL This alarm is considered a major alarm, and will turn off the modulator IF output. An alarm in this position indicates either a fault in the scrambler, or if the scrambler is disabled, the alarm indicates a loss of incoming data. If the fault is active with the scrambler turned off, check for input data at the DATA I/O connector. Activity alarm for the Q channel digital filter. AGC LEVEL Use the I channel procedure. Output power AGC level fault. MODEM REF ACT Indicates the level at the modulator output is not the programmed level. Modem REF ACT fault. MODEM REF PLL Indicates incorrect EXT REF frequency input. Modem REF PLL EXT REF ACT Indicates phase lock loop is unable to lock to EXT REF. External reference activity fault. MODULE Indicates clock reference not detected. Modulator module fault. CONFIGURATION Typically indicates that the modulator module is missing or will not program. Modulator/Demodulator Configuration fault. Indicates a fault in either the Modulator or Demodulator state. 5–13 SNM-1002 LinkSync Modem Maintenance 5.2.3.2 Revision 2 MN/SNM1002.OM Demodulator Faults Fault/Alarm CARRIER DETECT Possible Problem and Action Carrier detect fault. Indicates the decoder is not locked. This is the most common fault displayed in the modem. Any problem from the input data on the modulator end of the circuit to the output of the decoder can cause this alarm. IF SYNTHESIZER First, ensure the demodulator has an RF input at the proper frequency and power level. Ensure the demodulator data rate is properly programmed. Refer to the fault isolation procedure for Data Clock Sync in the modulator section. Verify the frequency of the data transmitted from the modulator is within 100 PPM. Demodulator IF synthesizer fault. Indicates the demodulator IF synthesizer is faulted. I CHANNEL Q CHANNEL This fault is a hardware failure. Contact the Comtech EFData Customer Support Department. Indicates a loss of activity in the I channel of the quadrature demodulator. Typically indicates a problem in the modulator side of the circuit. Check for proper RF input to the demodulator. If the input to the demodulator is correct, then the problem is in the baseband processing. Indicates a loss of activity in the Q channel of the quadrature demodulator. BER THRESHOLD Follow the same procedure for the I channel fault. Indicates the preset BER threshold has been exceeded. MODULE Setting of this alarm is done in the Utility menu. This is an alarm based on the corrected BER reading on the front panel. Demodulator module fault. CONFIGURATION Typically indicates that the demodulator module is missing or will not program. Contact the Comtech EFData Customer Support Department. Modulator/Demodulator Configuration fault. Indicates a fault in either the Modulator or Demodulator state. 5–14 SNM-1002 LinkSync Modem Maintenance 5.2.3.3 Revision 2 MN/SNM1002.OM Transmit Interface Faults Fault/Alarm TX DROP TX DATA/AIS Possible Problem and Action Not Applicable Data or incoming AIS. TX CLOCK PLL TX CLOCK ACT When the AIS is selected in the Interface Utility menu for TX data fault, the transmit interface fault TX data/AIS is monitoring a fault condition of all 1s from customer data input to the modem. When data is selected in the Interface Utility menu for TX data fault, the TX interface fault TX data/AIS is monitoring a fault condition of all 1s or 0s. This is referred to as a data-stable condition (data is not transitioning). This fault indicates there is trouble in the chain sending data to the modem. The modem passes this signal transparently, and takes no other action. This indication is a monitor function only, and aids in isolating the trouble source in a system. Not Applicable Activity detector alarm of the selected interface TX clock. CONFIGURATION Indicates the selected TX clock is not being detected. Check the signal of the selected TX clock source to verify the signal is present. The interface will fall back to the internal clock when this alarm is active. Modulator/Demodulator Configuration fault. Indicates a fault in either the Modulator or Demodulator state. 5–15 SNM-1002 LinkSync Modem Maintenance 5.2.3.4 Revision 2 MN/SNM1002.OM Receive Interface Faults Fault/Alarm BUFFER UNDERFLOW Possible Problem and Action Buffer underflow alarm. BUFFER OVERFLOW Indicates the plesiochronous buffer has underflowed. Buffer underflow is normally a momentary fault (there are clock problems if this alarm is continuously present). This alarm is included in this section to be consistent with the fault reporting system and to be correctly registered in the stored fault memory. The time and date of the first 10 receive buffer underflow faults are stored in battery-backed memory as an aid to troubleshooting. The interval between stored overflow/underflow events can be used to determine relative clock accuracies. Buffer overflow alarm. Indicates the plesiochronous buffer has overflowed. RX DATA/AIS FRAME BER BACKWARD ALARM The problems and actions in the buffer underflow section apply to this alarm. Data or incoming AIS. The data monitored for RX data is coming from the satellite. When the AIS is selected for RX data fault in the Interface Utility menu, the RX data/AIS is monitoring an alarm condition of all 1s from the satellite. When data is selected for RX data fault in the Interface Utility menu, the RX data/AIS is monitoring a fault condition of all 1s or 0s. This is referred to as a data-stable condition (data is not transitioning). The fault indicates trouble in receiving data from the satellite. The modem passes this signal transparently, and can close a FORM C contact. The indication is a monitor function only to help isolate the source of trouble in a system. Not Applicable Not Applicable 5–16 SNM-1002 LinkSync Modem Maintenance Fault/Alarm BUFFER CLK PLL BUFFER CLK ACT DEMUX_LOCK Revision 2 MN/SNM1002.OM Possible Problem and Action Buffer clock phase-locked loop fault. The buffer synthesizer is the wrong frequency or will not lock. Ensure the selected buffer clock source is at the proper frequency and level. If the fault continues, contact the Comtech EFData Customer Support Department. Activity detector alarm of the selected interface receive clock. The interface will fall back to the satellite clock when this fault is active. Demultiplexer synchronization lock fault. This fault means that the demultiplexer is unable to maintain valid frame and multiframe alignment. RX 2047 LOCK The usual cause is invalid or absent receive data. This is a major (prompt) alarm. The alarm will cause insertion of receive AIS (all 1s) and the switch-over will be attempted. This fault is to be sent as a backward alarm to the distant end. This fault will occur when no carrier is present, but will probably never occur with a correct signal. RX 2047 lock alarm. BUFFER FULL Indicates the RX 2047 data test pattern is not being received by the decoder. The alarm probably indicates the transmitter is not set correctly. Buffer full alarm. RX INSERT RX AUDIO 1 CLIP RX AUDIO 2 CLIP CONFIGURATION Indicates the buffer is < 10% or > 90% full. Not Applicable Not Appliable Not Applicable Modulator/Demodulator Configuration fault. Indicates a fault in either the Modulator or Demodulator state. 5–17 SNM-1002 LinkSync Modem Maintenance 5.2.3.5 Revision 2 MN/SNM1002.OM Common Equipment Faults Fault/Alarm BATTERY/CLOCK Possible Problem and Action M&C battery voltage or clock fault. -12 VOLT SUPPLY Indicates a low voltage in the memory battery. Typically, this fault will be active when a modem has been hard reset or the firmware has been changed. When a hard reset has been executed or the firmware has been changed, this fault will typically be active when the modem is first turned on. -12V power supply fault. Indicates a high or low voltage condition. Level is ± 5%. +12 VOLT SUPPLY Check for a short on the –12V line from the power supply or on any of the plug-in boards. +12 VDC power supply fault. Use the same procedure as with –12V fault. +5 VOLT SUPPLY +5V power supply fault. Use the same procedure as with a –12V fault. SELF TEST The +5V supply requires a minimum load of 1A. Self test Fault. CONTROLLER Indicates a failed Self Test by sending a signal through the RF loopback and IF loopback and checking for quality. Controller fault. INTERFACE Indicates a loss of power in the M&C card. Typically indicates the controller has gone through a power on/off cycle. Interface module fault. Indicates a problem in programming the interface card. 5–18 Appendix A. REMOTE CONTROL OPERATION This appendix describes the remote control operation of the SNM-1002 LinkSync™. • • Firmware number: Software version: FW/6535-3G 4.1.5 Note: The firmware referenced in this manual may be an earlier version of the actual firmware supplied with the unit. A.1 General Note: Under normal operation, the MIDAS NMS configures and controls the LinkSync modem for all the functions it provides using the remote control port. For purpose of this manual, the complete list of Remote Commands are provided. However, for practical usage, these remote commands will likely never be used nor required by an operator. Remote controls and status information are transferred via an EIA-232 serial communications link. Commands and data are transferred on the remote control communications link as US ASCII-encoded character strings. The remote communications link is operated in a half-duplex mode. Communications on the remote link are initiated by a remote controller or terminal. The modem never transmits data on the link unless it is commanded to do so. A–1 SNM-1002 LinkSync Modem Remote Control Operation A.2 Revision 2 MN/SNM1002.OM Message Structure The ASCII character format used requires 11 bits/character: • • • • 1 start bit 7 information bits 1 parity bit 2 stop bits Messages on the remote link fall into the categories of commands and responses. Commands are messages which are transmitted to a satellite modem, while responses are messages returned by a satellite modem in response to a command. The general message structure is as follows: • • • • A.2.1 Start Character Device Address Command/Response End of Message Character Start Character A single character precedes all messages transmitted on the remote link. This character flags the start of a message. This character is: • • A.2.2 “<” for commands “>” for responses Device Address The device address is the address of the one satellite modem which is designated to receive a transmitted command, or which is responding to a command. Valid device addresses are 1 to 3 characters long, and in the range of 1 to 255. Address 0 is reserved as a global address which simultaneously addresses all devices on a given communications link. Devices do not acknowledge global commands. Each satellite modem which is connected to a common remote communications link must be assigned its own unique address. Addresses are software selectable at the modem, and must be in the range of 1 to 255. A–2 SNM-1002 LinkSync Modem Remote Control Operation A.2.3 Revision 2 MN/SNM1002.OM Command/Response The command/response portion of the message contains a variable-length character sequence which conveys command and response data. If a satellite modem receives a message addressed to it which does not match the established protocol or cannot be implemented, a negative acknowledgment message is sent in response. This message is: • >add/?ER1_parity error'cr''lf'] (Error message for received parity errors.) • >add/?ER2_invalid parameter'cr''lf'] (Error message for a recognized command which cannot be implemented or has parameters which are out of range.) • >add/?ER3_unrecognizable command'cr''lf'] (Error message for unrecognizable command or bad command syntax.) • >add/?ER4_modem in local mode'cr''lf'] (Modem in local error; send the REM command to go to remote mode.) • >add/?ER5_hard coded parameter'cr''lf'] (Error message indicating that the parameter is hardware dependent and may not be changed remotely.) Note: “add” is used to indicate a valid 1 to 3 character device address in the range between 1 and 255. A.2.4 End Character Each message is ended with a single character which signals the end of the message: • • “cr” “]” Carriage return character for commands End bracket for responses A–3 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM A.3 Configuration Commands/Responses A.3.1 Modulator Modulator Frequency RF Output (IF Output) Modulator Rate Preset Assignment Where: nnn.nnnn = Frequency in MHz, 50.000000 to 180.000000 in 1 Hz steps. Command: Response: <add/MF_nnn.nnnnnn'cr' >add/MF_nnn.nnnnnn'cr' RF_OFF'cr''lf'] Status: Response: <add/MF_'cr' >add/MF_nnn.nnnnnn'cr''lf'] Command: Response: <add/RF_xxx'cr' >add/RF_xxx'cr''lf'] Status: Response: <add/RF_'cr' >add/RF_xxx'cr''lf'] Command: Response: <add/AMRx_nnnn_mmmm.mmm'cr' >add/AMRx_nnnn_mmmm.mmm'cr''lf'] Status: Response: <add/AMRx_'cr' >add/AMRx_nnnn_mmmm.mmm'cr''lf'] Note: When the modulator frequency is programmed, the RF output is switched off. Where: xxx = ON or OFF. Where: x = A, B, C, D, or V [preset designator]. nnnn = 1/2 (QPSK 1/2), [coder rate], 3/4 (QPSK 3/4), 7/8 (QPSK 7/8), BP12 (BPSK 1/2), 8P23 (8PSK 2/3). mmmm.mmm = Data rate in kHz. Modulator Rate Preset Selection Modulator Rate Variable Assignment & Selection Where: x = A, B, C, D, or V (preset designator). Command: Response: <add/SMRx_'cr' >add/SMRx_'cr' RF_OFF'cr''lf'] Status: See MR command. Command: Response: <add/SMRV_nnnn_mmmm.mmm'cr' >add/SMRV_nnnn_mmmm.mmm'cr' RF_OFF'cr''lf'] Status: Note: Setting the modulator rate turns off the RF transmitter. See MR command. Where: nnnn = 1/2 (QPSK 1/2), [coder rate], 3/4 (QPSK 3/4), 7/8 (QPSK 7/8), BP12 (BPSK 1/2), 8P23 (8PSK 2/3). mmmm.mmm = Data rate in kHz. Note: Setting the modulator turns off the RF transmitter. Set Modulator Power Offset Command: Response: <add/MPO_snn.n'cr' >add/MPO_snn.n'cr''lf'] Where: snn.n = +99.0 to -99.0, in 0.1 dB increments. Status: Response: <add/MPO_'cr' >add/MPO_snn.n'cr''lf'] Note: The modulator power offset is added to the nominal power level to adjust the transmit power range. A–4 SNM-1002 LinkSync Modem Remote Control Operation Set Modulator Output Power Level Revision 2 MN/SNM1002.OM Command: Response: <add/MOP_snn.n'cr' >add/MOP_snn.n'cr''lf'] Where: snn.n = -30.0 to -5.0, in 0.1 steps (nominal range in dBm). Status: Response: <add/MOP_'cr' >add/MOP_snn.n'cr''lf'] Notes: 1. 2. The nominal power range is modified relativeto the value specified by the modulator power offset (MPO_). The MOP_ command will return status only when local AUPC is enabled. Where: xxx = ON or OFF. Command: Response: <add/SE_xxx'cr' >add/SE_xxx'cr''lf'] Status: Response: <add/SE_'cr' >add/SE_xxx'cr''lf'] Command: Response: <add/DENC_xxx'cr' >add/DENC_xxx'cr''lf'] Status: Response: <add/DENC_'cr' >add/DENC_xxx'cr''lf'] Command: Response: <add/MT_xxxx'cr' >add/MT_xxxx'cr''lf'] Status: Response: <add/MT_xxxx'cr' >add/MT_xxxx'cr''lf'] Where: xxxx = INTL (INTELSAT OPEN NETWORK), EFD (EF DATA CLOSED NETWORK), CSC (COMSTREAM CLOSED NETWORK), FDC (FAIRCHILD CLOSED NETWORK), SDM51 (SDM51 COMPATIBLE). Command: Response: <add/MET_xxx'cr' >add/MET_xxx'cr''lf'] Where: xxx = VIT (K-7 VITERBI ENCODER), SEQ (SEQUENTIAL ENCODER). Status: Response: <add/MET_xxx'cr' >add/MET_xxx'cr''lf'] Command: Response: <add/MRC_xxxxx'cr' >add/MRC_xxxxx'cr''lf'] Status: Response: <add/MRC_'cr' >add/MRC_xxxxx'cr''lf'] Where: xxxxx = INT (INTERNAL), EXT1 (EXTERNAL 1 MHz), EXT5 (EXTERNAL 5 MHz), EXT10 (EXTERNAL 10 MHz), EXT20 (EXTERNAL 20 MHz), OUT10 (OUTPUT 10 MHz). Command: Response: <add/MSR_xxx'cr' >add/MSR_xxx'cr''lf'] Where: xxx = NRM (normal spectrum), INV (inverted spectrum). Status: Response: <add/MSR_'cr' >add/MSR_xxx'cr''lf'] Transmit BPSK Data Ordering Command: Response: <add/TDA_xxx'cr' >add/TDA_xxx'cr''lf'] Status: Response: <add/TDA_xxx'cr' >add/TDA_xxx'cr''lf'] Carrier Only Mode Command: Response: <add/COM_xxxxxx'cr' >add/COM_xxxxxx'cr''lf'] Status: Response: <add/COM_xxxxxx'cr' >add/COM_xxxxxx'cr''lf'] Scrambler Enable Differential Encoder Enable Modulator Type Modulator Encoder Type Modem Reference Clock Modulator Spectrum Rotation Where: xxx = ON or OFF. Where: xxx = NRM (STANDARD), INV (NONSTANDARD). Where: xxxxxx = OFF (NORMALMODULATED), DUAL (DUAL-CW), OFFSET (OFFSET-CW), CENTER (CENTER-CW). A–5 SNM-1002 LinkSync Modem Remote Control Operation A.3.2 Set Demodulator Frequency Demodulator Rate Preset Assignment Revision 2 MN/SNM1002.OM Demodulator Command: Response: <add/DF_nnn.nnnnnn'cr' >add/DF_nnn.nnnnnn'cr''lf'] Status: Response: <add/DF_'cr' >add/DF_nnn.nnnnnn'cr''lf'] Command: Response: <add/ADRx_nnnn_mmmm.mmm'cr' >add/ADRx_nnnn_mmmm.mmm'cr''lf'] Status: Response: <add/ADRx_'cr' >add/ADRx_nnnn_mmmm.mmm'cr''lf'] Where: nnn.nnnn = Frequency in MHz, 50.000000 to 180.000000 in 1 Hz steps. Where: x = A, B, C, D, or V [preset designator]. nnnn = 1/2 (QPSK 1/2), [decoder rate], 3/4 (QPSK 3/4), 7/8 (QPSK 7/8), BP12 (BPSK 1/2), 8P23 (8PSK 2/3). mmmm.mmm = Data rate in kHz. Demodulator Rate Preset Selection Demodulator Rate Variable Assignment & Selection Where: x = A, B, C, D, or V (preset designator). Command: Response: <add/SDRx_'cr' >add/SDRx_'cr''lf'] Status: See DR command. Command: Response: <add/SDRV_nnnn_mmmm.mmm'cr' >add/SDRV_nnnn_mmmm.mmm'cr''lf'] Status: See DR command. Where: nnnn = 1/2 (QPSK 1/2), [decoder rate], 3/4 (QPSK 3/4), 7/8 (QPSK 7/8), BP12 (BPSK 1/2), 8P23 (8PSK 2/3). mmmm.mmm = Data rate in kHz. Descramble Enable Differential Decoder Enable RF Loopback Command: Response: <add/DE_xxx'cr' >add/DE_xxx'cr''lf'] Status: Response: <add/DE_'cr' >add/DE_xxx'cr''lf'] Command: Response: <add/DDEC_xxx'cr' >add/DDEC_xxx'cr''lf'] Status: Response: <add/DDEC_'cr' >add/DDEC_xxx'cr''lf'] Command: Response: <add/RFL_xxx'cr' >add/RFL_xxx'cr''lf'] Status: Response: <add/RFL_'cr' >add/RFL_xxx'cr''lf'] Where: xxx = ON or OFF. Where: xxx = ON or OFF. Where: xxx = ON or OFF. A–6 SNM-1002 LinkSync Modem Remote Control Operation IF Loopback Sweep Center Frequency Sweep Width Range Sweep Reacquisition Bit Error Rate Threshold Demodulator Type Demodulator Decoder Type Demodulator Spectrum Rotation Receive BPSK Data Ordering Revision 2 MN/SNM1002.OM Command: Response: <add/IFL_xxx'cr' >add/IFL_xxx'cr''lf'] Status: Response: <add/IFL_'cr' >add/IFL_xxx'cr''lf'] Command: Response: <add/SCF_snnnnn'cr' >add/SCF_snnnnn'cr''lf'] Status: Response: <add/SCF_'cr' >add/SCF_snnnnn'cr''lf'] Command: Response: <add/SWR_nnnnn'cr' >add/SWR_nnnnn'cr''lf'] Status: Response: <add/SWR_'cr' >add/SWR_nnnnn'cr''lf'] Command: Response: <add/SR_xxx'cr' >add/SR_xxx'cr''lf'] Status: Response: <add/SR_'cr' >add/SR_xxx'cr''lf'] Command: Response: <add/BERT_xxxx'cr' >add/BERT_xxxx'cr''lf'] Status: Response: <add/BERT_'cr' >add/BERT_xxxx'cr''lf'] Command: Response: <add/DT_xxxx'cr' >add/DT_xxxx'cr''lf'] Status: Response: <add/DT_xxxx'cr' >add/DT_xxxx'cr''lf'] Command: Response: <add/DDT_xxx'cr' >add/DDT_xxx'cr''lf'] Status: Response: <add/DDT_xxx'cr' >add/DDT_xxx'cr''lf'] Command: Response: <add/DSR_xxx'cr' >add/DSR_xxx'cr''lf'] Status: Response: <add/DSR_'cr' >add/DSR_xxx'cr''lf'] Command: Response: <add/RDA_xxx'cr' >add/RDA_xxx'cr''lf'] Status: Response: <add/RDA_xxx'cr' >add/RDA_xxx'cr''lf'] Where: xxx = ON or OFF. Where: snnnnn = -35000 to +35000, in 1 Hz steps. Where: nnnnn = 0 to 70000, in 1 Hz steps. Where: xxx = 0 to 999 (number of seconds). Where: xxxx = NONE, or 1E-n, where n = 3, 4, 5, 6, 7, or 8 (exponent of threshold). Where: xxxx = INTL (INTELSAT OPEN NETWORK), EFD (EF DATA CLOSED NETWORK), CSC (COMSTREAM CLOSED NETWORK), FDC (FAIRCHILD CLOSED NETWORK). Where: xxx = VIT (K-7 VITERBI ENCODER), SEQ (SEQUENTIAL ENCODER). Where: xxx = NRM (normal spectrum), INV (inverted spectrum). Where: xxx = NRM (STANDARD), INV (NON-STANDARD). A–7 SNM-1002 LinkSync Modem Remote Control Operation A.3.3 Interface Interface Transmit Overhead Type Command: Response: <add/ITOT_xxxxx'cr' >add/ITOT_xxxxx'cr''lf'] Status: Response: <add/ITOT_'cr' >add/ITOT_xxxxx'cr''lf'] Interface Receive Overhead Type Command: Response: <add/IROT_xxxxx'cr' >add/IROT_xxxxx'cr''lf'] Status: Response: <add/IROT_'cr' >add/IROT_xxxxx'cr''lf'] TX Driver Type Command: Response: <add/TXDR_xxxxx'cr' >add/TXDR_xxxxx'cr''lf'] Status: Response: <add/TXDR_'cr' >add/TXDR_xxxxx'cr''lf'] Command: Response: <add/RXDR_xxxxx'cr' >add/RXDR_xxxxx'cr''lf'] Status: Response: <add/RXDR_'cr' >add/RXDR_xxxxx'cr''lf'] Command: Response: <add/TC_xxx'cr' >add/TC_xxx'cr''lf'] Status: Response: <add/TC_'cr' >add/TC_xxx'cr''lf'] External ClockReference Frequency Command: Response: <add/ERF_nnnnn.n'cr' >add/ERF_nnnnn.n'cr''lf'] Status: Response: <add/ERF_'cr' >add/ERF_nnnnn.n'cr''lf'] Transmit Clock Phase Command: Response: <add/TCP_xxxx'cr' >add/TCP_xxxx'cr''lf'] Status: Response: <add/TCP_'cr' >add/TCP_xxxx'cr''lf'] Command: Response: <add/BC_xxx'cr' >add/BC_xxx'cr''lf'] Status: Response: <add/BC_'cr' >add/BC_xxx'cr''lf'] Command: Response: <add/RCP_xxx'cr' >add/RCP_xxx'cr''lf'] Status: Response: <add/RCP_'cr' >add/RCP_xxx'cr''lf'] RX Driver Type Transmit Clock Buffer Clock Receive Clock Phase Revision 2 MN/SNM1002.OM Where: xxxxx = NONE Where: xxxxx = NONE Where: xxxxx = V35, RS422, or RS232. Where: xxxxx = V35, RS422, or RS232. Where: xxx = INT (internal SCT clock), EXT (external TX terrestrial clock), REF (external clockreference frequency). Where: nnnnn.n = 8.0 to 10000.0 (external clock frequency in kHz). Where: xxxx = NRM (normal clock phasing), INV (inverted clock phasing), AUTO (automatic clock phasing). Where: xxx = INT (internal SCT clock), EXT (external TX terrestrial clock), SAT (receive satellite clock), REF (external clock-reference frequency), INS (insert clock). Where: xxx = NRM (normal clock phasing), INV (inverted clock phasing). A–8 SNM-1002 LinkSync Modem Remote Control Operation Baseband Loopback Interface Loopback Interface Loop Timing Interface Buffer Size Command: Response: <add/BBL_xxx'cr' >add/BBL_xxx'cr''lf'] Status: Response: <add/BBL_'cr' >add/BBL_xxx'cr''lf'] Command: Response: <add/ILB_xxx'cr' >add/ILB_xxx'cr''lf'] Status: Response: <add/ILB_'cr' >add/ILB_xxx'cr''lf'] Command: Response: <add/ILT_xxx'cr' >add/ILT_xxx'cr''lf'] Status: Response: <add/ILT_'cr' >add/ILT_xxx'cr''lf'] Revision 2 MN/SNM1002.OM Where: xxx = ON or OFF. Where: xxx = ON or OFF. Where: xxx = ON or OFF. Buffer size programming is supported in two formats; bits, or milli-seconds. The selected format must be chosen using the buffer programming command (IBP_). If the buffer is to be programmed in milli-seconds and plesiochronous slips are required use the receive framing structure command (IRFS_) to define the proper framing format. Note: For Drop & Insert: Only milli-seconds format is allowed. Interface Buffer Size (Bit Format) Command: Response: <add/IBS_nnnnnn'cr' >add/IBS_nnnnnn'cr''lf'] Status: Response: <add/IBS_'cr' >add/IBS_nnnnnn'cr''lf'] Interface Buffer Size (Millisecond Format) Command: Response: <add/IBS_nn'cr' >add/IBS_nn'cr''lf'] Status: Response: <add/IBS_'cr' >add/IBS_nn'cr''lf'] Interface Buffer Center Command: Response: <add/IBC_'cr' >add/IBC_'cr''lf'] Interface Buffer Programming Command: Response: <add/IBP_xxxx'cr' >add/IBP_xxxx'cr''lf'] Status: Response: <add/IBP_'cr' >add/IBP_xxxx'cr''lf'] Interface Receive Farming Structure Command: Response: <add/IRFS_ff_ssss'cr' >add/IRFS_ff_ssss'cr''lf'] Status: Response: <add/IRFS_ff'cr' >add/IRFS_ff_ssss'cr''lf'] Where: nnnnnn = 32 to 262144, in 16 bit increments. Where: nn = 0 to 99 (buffer size in milli-seconds). Note: For Drop & Insert: 1. nn = 7.5, 15, or 30 (milli-seconds) for E1CAS format. 2. nn = 6, 12, 24, or 30 (milli-seconds) for T1S/T1ESFS format. 3. nn = 1, 2, 4, 8, 16, or 32 (milliseconds) for all other D&I formats. Where: xxxx = BITS or MS (milli-seconds). Note: For Drop & Insert: Only milli-seconds format is allowed. Where: ff = T1 or E1 (frame type). ssss = NONE or G704 (framing structure). A–9 SNM-1002 LinkSync Modem Remote Control Operation Transmit Data Phase Receive Data Phase CTS Delay Time A.3.4 Time Of Day Date Command: Response: <add/TDP_xxxx'cr' >add/TDP_xxxx'cr''lf'] Status: Response: <add/TDP_'cr' >add/TDP_xxxx'cr''lf'] Command: Response: <add/RDP_xxxx'cr' >add/RDP_xxxx'cr''lf'] Status: Response: <add/RDP_'cr' >add/RDP_xxxx'cr''lf'] Command: Response: <add/CTSD_xx'cr' >add/CTSD_xx'cr''lf'] Status: Response: <add/CTSD_'cr' >add/CTSD_xx'cr''lf'] Revision 2 MN/SNM1002.OM Where: xxxx = NRM (normal data phasing), INV (inverted data phasing). Where: xxxx = NRM (normal data phasing), INV (inverted data phasing). Where: xx = 0 to 60 (number of seconds). System Where: hh = 1 to 12 (hours). mm = 00 to 59 (minutes). xx = AM or PM. Command: Response: <add/TIME_hh:mmxx'cr' >add/TIME_hh:mmxx'cr''lf'] Status: Response: <add/TIME_'cr' >add/TIME_hh:mmxx'cr''lf'] Command: Response: <add/DATE_mm/dd/yyyy'cr' >add/DATE_mm/dd/yyyy'cr''lf'] Status: Response: <add/DATE_'cr' >add/DATE_mm/dd/yyyy'cr''lf'] Where: mm = 1 to 12 (month). dd = 1 to 31 (day). yyyy = 00 to 99 (year) in 2 - digit year mode, and 1975 to 1999 and 2000 to 2075 in 4 - digit mode. Remote Command: Response: <add/REM_'cr' >add/REM_'cr''lf'] Configures the modem for remote operation. The SDM300A will respond to any status request at any time. However, the SDM300A must be in 'Remote Mode' to change configuration parameters. Clear Stored Faults Modem Operation Mode Command: Response: <add/CLSF_'cr' >add/CLSF_'cr''lf'] This command is used to clear all stored faults logged by the SDM300A. Command: Response: <add/MOM_xxxxxxx'cr' >add/MOM_xxxxxxx'cr''lf'] Where: xxxxxxx = TX_ONLY, RX_ONLY, or DUPLEX. Status: Response: <add/MOM_'cr' >add/MOM_xxxxxxx'cr''lf'] This command configures the modem for simplex or duplex operation modes. When transmit only mode is selected, receive faults are inhibited and when receive only mode is selected, transmit faults are inhibited. A–10 SNM-1002 LinkSync Modem Remote Control Operation System Modem Type Save Modem Config. Command: Response: <add/SMT_xxxxxxx'cr' >add/SMT_xxxxxxx'cr''lf'] Status: Response: <add/SMT_'cr' >add/SMT_xxxxxxx'cr''lf'] Command: Response: <add/SMC_n'cr' >add/SMC_n'cr''lf'] Revision 2 MN/SNM1002.OM Where: xxxxxx = EFD or CUSTOM. Where: n = 1, 2, 3, 4, or 5 (stored configuration number). This command saves the current modem configuration for recall at a later time using the 'RMC_' command. Up to five different modem configurations can be saved. Recall Modem Config. Command: Response: Where: n = 1, 2, 3, 4, or 5 (stored configuration number). <add/RMC_n'cr' >add/RMC_n'cr''lf'] This command causes the modem to be reprogrammed with configuration parameters previously saved using the 'SMC_' command. One of five saved configurations can be specified. RTS TX-IF Control Mode RF Mode Control Command: Response: <add/RTSM_xxx'cr' >add/RTSM_xxx'cr''lf'] Status: Response: <add/RTSM_'cr' >add/RTSM_xxx'cr''lf'] Command: Response: <add/RFMD_xxxx'cr' >add/RFMD_xxxx'cr''lf'] Status: Response: <add/RFMD_xxxx'cr' >add/RFMD_xxxx'cr''lf'] Where: xxx = ON or OFF. This command configures the modem for the RTS TX-IF control mode. If 'ON' is selected, the TX-IF output will only be turned on if the incoming RTS signal is asserted (also the TX-IF output has to be programmed ON and no major modulator faults are present). If 'OFF' is selected, the TX-IF output will operate normal ignoring the RTS signal. Where: xxxx = NRM (Normal Mode), PWR (Turn RF off on power up), COMM (Turn RF off on power up and loss of remote communications after 10 seconds), CD (Turn RF ON when carrier is detected, turn RF OFF when no carrier is detected. For the RF ON condition, the TX-IF must be programmed ON. Note: RTS TX-IF, when enabled over-rides CD). This command allows for the RF output to be enabled or disabled depending on the following described conditions. One application for this command will be in demand network systems. A–11 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM A.4 Status Commands/Responses Modulator Config. Status Command: Response: <add/MCS_'cr' >add/MCS_'cr' RF_xxx'cr' MF_nnn.nnnnnn'cr' MR_nnnn_mmmm.mmm'cr' AMRA_nnnn_mmmm.mmm'cr' AMRB_nnnn_mmmm.mmm'cr' AMRC_nnnn_mmmm.mmm'cr' AMRD_nnnn_mmmm.mmm'cr' AMRV_nnnn_mmmm.mmm'cr' MPO_snn.n'cr' MOP_snn.n'cr' SE_xxx'cr' DENC_xxx'cr' MT_xxxxx'cr' MET_xxx'cr' COM_xxxxxx'cr' MRC_xxx'cr' MSR_xxx'cr' RSEN_xxx'cr' TDA_xxx'cr' TRSI_xx'cr' T310_xxx'cr''lf'] RF Output Modulator Frequency Modulator Rate Preset 'A' Assignment Preset 'B' Assignment Preset 'C' Assignment Preset 'D' Assignment Preset 'V' Assignment Modulator Power Offset Modulator Output Power Scrambler Enable Differential Encoder Modulator Type Modulator Encoder Type Carrier Only Mode Modulator Reference Clock Modulator Spectrum Rotation Reed-Solomon Encoder Transmit BPSK Data Ordering TX Reed-Solomon Interleave Value TX 8PSK 2/3 IESS-310 Operation The modulator configuration status command causes a block of data to be returned by the addressed modem. The block of data reflects the current configuration status of the modulator module. Additional configuration status of new options and features will always be appended to the end. Modulator/ Coder Config. Program Status Command: Response: <add/MCP_'cr' >add/MCP_'cr' SMT_xxxxxxx'cr' ITOT_xxxxx'cr' MOM_xxxxxxx'cr' MT_xxxxx'cr' MET_xxx'cr' TCEN_1_xxxx'cr' TCDR_1_xxxx.x'cr' TCEN_2_xxx'cr' TCEN_3_xxxx'cr' TCDR_3_xxxx.x'cr' TCCP_3_yyy'cr' TCDP_3_yyy'cr' TCEN_4_xxxx'cr' TCDR_4_xxxx.x'cr' TCCP_4_yyy'cr' TCDP_4_yyy'cr' System Modem Type Interface Transmit Overhead Type Modem Operation Mode Modulator Type Modulator Encoder Type Flex Mux TX Channel #1 Enable Flex Mux TX Channel #1 Data Rate Flex Mux TX Channel #2 Enable Flex Mux TX Channel #3 Enable Flex Mux TX Channel #3 Data Rate Flex Mux TX Channel #3 Clock Phase Flex Mux TX Channel #3 Data Phase Flex Mux TX Channel #4 Enable Flex Mux TX Channel #4 Data Rate Flex Mux TX Channel #4 Clock Phase Flex Mux TX Channel #4 Data Phase Modulator Frequency Modulator Rate Modulator Power Offset AUPC Local Power Enable Modulator Output Power (Note 1) (Note 2) (Note 1) (Note 1) (Note 3) (Note 3) (Note 3) (Note 1) (Note 4) (Note 4) (Note 4) MF_nnn.nnnnnn'cr' MR_nnnn_mmmm.mmm'cr' MPO_snn.n'cr' LPC_xxx'cr' (Note 5) MOP_snn.n'cr' (Note 6) SE_xxx'cr' A–12 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM DENC_xxx'cr' ILT_xxx'cr' ERF_nnnnn.n'cr' TC_xxxx'cr' TCP_xxxx'cr' BBL_xxx'cr' ILB_xxx'cr' ILT_xxx'cr' ICFT_xxxx'cr' ISP_xxxxxx'cr' ISP_xxx'cr' TDF_xxxx'cr' ISCL_TX1_nnn'cr' ISCL_TX2_nnn'cr' TDP_xxxx'cr' DDF_xxxxxx'cr' (Note 7) BDCA_dd;cc_dd;cc...'cr' (Note 7) MRC_xxx'cr' MSR_xxx'cr' RSEN_xxx'cr' BW_TX1_nnn'cr' (Note 8) BW_TX2_nnn'cr' (Note 8) BW_TX3_nnn'cr' (Note 8) BW_TX4_nnn'cr' (Note 8) TXDR_xxxxxx'cr' TOBR_nnnnn'cr' (Note 9) TCCL_n'cr' (Note 9) TCSB_n'cr' (Note 9) TOCP_xxxx'cr' (Note 9) TCT_xxxxx'cr' (Note 9) NOMP_snn.n'cr' (Note 5) MINP_snn.n'cr' (Note 5) MAXP_snn.n'cr' (Note 5) LCL_xxxx'cr' (Note 5) RCL_xxxx'cr' (Note 5) CTSD_xx'cr' RTSM_xxx'cr' TDA_xxx'cr' COM_xxxxxx'cr' TET_xxxxx'cr' (Note 8) MTDR_1_yyyyyy'cr' (Note 10) MTIT_1_yyyyy'cr' (Note 10) MTCP_1_yyy'cr' (Note 10) MTDP_1_yyy'cr' (Note 10) MTMD_1_yyyyy'cr' (Note 10) MTAF_1_yyy'cr' (Note 10) MTDR_2_yyyyyy'cr' (Note 10) MTIT_2_yyyyy'cr' (Note 10) MTCP_2_yyy'cr' (Note 10) MTDP_2_yyy'cr' (Note 10) MTMD_2_yyyyy'cr' (Note 10) MTAF_2_yyy'cr' (Note 10) MTDR_3_yyyyyy'cr' (Note 10) MTIT_3_yyyyy'cr' (Note 10) MTCP_3_yyy'cr' (Note 10) MTDP_3_yyy'cr' (Note 10) MTMD_3_yyyyy'cr' (Note 10) MTAF_3_yyy'cr' (Note 10) MTDR_4_yyyyyy'cr' (Note 10) MTIT_4_yyyyy'cr' (Note 10) MTCP_4_yyy'cr' (Note 10) A–13 Scrambler Enable Differential Encoder Interface Loop Timing External Reference Frequency Transmit Clock (Source) Transmit Clock Phase Baseband Loopback Interface Loopback Interface Loop Timing Interface Coding Format Transmit Interface Substitution Pattern (TX 2047) Interface Substitution Pattern (TX 2047) Transmit Data Fault Service Channel Level TX1 Service Channel Level TX2 Transmit Data Phase Drop Data Format Bulk Drop Channels Assignment Modulator Reference Clock Modulator Spectrum Rotation Reed-Solomon Encoder Backward Alarm Enable TX1 Backward Alarm Enable TX2 Backward Alarm Enable TX3 Backward Alarm Enable TX4 TX Driver Type ASYNC Transmit Overhead Baud Rate ASYNC Transmit Channel Character Length ASYNC Transmit Channel Stop Bits ASYNC Transmit Overhead Channel Parity ASYNC Transmit Communications Type AUPC Nominal Power Value AUPC Minimum Power Value AUPC Maximum Power Value AUPC Local Carrier Loss AUPC Remote Carrier Loss CTS Delay Time RTS TX-IF Control Mode Transmit BPSK Data Ordering Carrier Only Mode IDR Transmit ESC Type Mux Tributary #1 Data Rate & Enable Mux Tributary #1 Interface Type Mux Tributary #1 Clock Phase Mux Tributary #1 Data Phase Mux Tributary #1 Mode Mux Tributary #1 Async Mode Mux Tributary #2 Data Rate & Enable Mux Tributary #2 Interface Type Mux Tributary #2 Clock Phase Mux Tributary #2 Data Phase Mux Tributary #2 Mode Mux Tributary #2 Async Mode Mux Tributary #3 Data Rate & Enable Mux Tributary #3 Interface Type Mux Tributary #3 Clock Phase Mux Tributary #3 Data Phase Mux Tributary #3 Mode Mux Tributary #3 Async Mode Mux Tributary #4 Data Rate & Enable SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM MTDP_4_yyy'cr' (Note 10) MTMD_4_yyyyy'cr' (Note 10) MTAF_4_yyy'cr' (Note 10) MTDR_5_yyyyyy'cr' (Note 10) MTIT_5_yyyyy'cr' (Note 10) MTCP_5_yyy'cr' (Note 10) MTDP_5_yyy'cr' (Note 10) MTMD_5_yyyyy'cr' (Note 10) MTAF_5_yyy'cr' (Note 10) MTDR_6_yyyyyy'cr' (Note 10) MTIT_6_yyyyy'cr' (Note 10) MTCP_6_yyy'cr' (Note 10) MTDP_6_yyy'cr' (Note 10) MTMD_6_yyyyy'cr' (Note 10) MTAF_6_yyy'cr' (Note 10) MTDR_7_yyyyyy'cr' (Note 10) MTIT_7_yyyyy'cr' (Note 10) MTCP_7_yyy'cr' (Note 10) MTDP_7_yyy'cr' (Note 10) MTMD_7_yyyyy'cr' (Note 10) MTAF_7_yyy'cr' (Note 10) MTDR_8_yyyyyy'cr' (Note 10) MTIT_8_yyyyy'cr' (Note 10) MTCP_8_yyy'cr' (Note 10) MTDP_8_yyy'cr' (Note 10) MTMD_8_yyyyy'cr' (Note 10) MTAF_8_yyy'cr' (Note 10) TRSI_xx'cr' T310_xxx'cr' RF_xxx'cr''lf'] Mux Tributary #4 Interface Type Mux Tributary #4 Clock Phase Mux Tributary #4 Data Phase Mux Tributary #4 Mode Mux Tributary #4 Async Mode Mux Tributary #5 Data Rate & Enable Mux Tributary #5 Interface Type Mux Tributary #5 Clock Phase Mux Tributary #5 Data Phase Mux Tributary #5 Mode Mux Tributary #5 Async Mode Mux Tributary #6 Data Rate & Enable Mux Tributary #6 Interface Type Mux Tributary #6 Clock Phase Mux Tributary #6 Data Phase Mux Tributary #6 Mode Mux Tributary #6 Async Mode Mux Tributary #7 Data Rate & Enable Mux Tributary #7 Interface Type Mux Tributary #7 Clock Phase Mux Tributary #7 Data Phase Mux Tributary #7 Mode Mux Tributary #7 Async Mode Mux Tributary #8 Data Rate & Enable Mux Tributary #8 Interface Type Mux Tributary #8 Clock Phase Mux Tributary #8 Data Phase Mux Tributary #8 Mode Mux Tributary #8 Async Mode TX Reed-Solomon Interleave Value TX 8PSK 2/3 IESS-310 Operation RF Output (ON/OFF) This command is used by the Adaptive Boradband M:N protection switch to collect information that is necessary to configure backup modems. Because this command (content and/or order) can be changed at any time by Adaptive Boradband, it is advisable that other commands ('MCS_' and 'ICS_', or 'BCS_') be used for M&C systems. Notes: 1 2. 3. 4. 5 Data is only returned if FLEX MUX PCB (Card Slot #1) is installed. Data not returned if Channel #1 is disabled. Data not returned if Channel #3 is disabled or set for AUPC. Data not returned if Channel #4 is disabled or set for AUPC. Data is only returned for TX ASYNC Overhead( or Flex Mux AUPC). 6. Data not returned if Local AUPC is enabled & TX ASYNC overhead. 7. Data is only returned for TX D&I Overhead. Data is only returned for TX IDR Overhead. Data is only returned for TX ASYNC Overhead (or Flex Mux D&I). 10. Data is only returned if MUX PCB (Card Slot #1) is installed. A–14 SNM-1002 LinkSync Modem Remote Control Operation Demodulat or Config. Status Command: Response: Revision 2 MN/SNM1002.OM <add/DCS_'cr' >add/DCS_'cr' DF_nnn.nnnnnn'cr' DR_nnnn_mmmm.mmm'cr' ADRA_nnnn_mmmm.mmm'cr' ADRB_nnnn_mmmm.mmm'cr' ADRC_nnnn_mmmm.mmm'cr' ADRD_nnnn_mmmm.mmm'cr' ADRV_nnnn_mmmm.mmm'cr' DE_xxx'cr' DDEC_xxx'cr' RFL_xxx'cr' IFL_xxx'cr' SCF_snnnnn'cr' SWR_nnnnn'cr' SR_xxx'cr' BERT_xxxx'cr' DT_xxxx'cr' DDT_xxx'cr' DSR_xxx'cr' RSDE_xxx'cr' RDA_xxx'cr' RRSI_xx'cr' R310_xxx'cr''lf'] Demodulator Frequency Demodulator Rate Preset 'A' Assignment Preset 'B' Assignment Preset 'C' Assignment Preset 'D' Assignment Preset 'V' Assignment Descrambler Enable Differential Decoder RF Loopback IF Loopback Sweep Center Frequency Sweep Width Range Sweep Reacquisition BER Threshold Demodulator Type Demodulator Decoder Type Demodulator Spectrum Rotation Reed-Solomon Decoder Receive BPSK Data Ordering RX Reed-Solomon Interleave Value RX 8PSK 2/3 IESS-310 Operation The demodulator configuration status command causes a block of data to be returned by the addressed modem. The block of data reflects the current configuration of the demod. Additional configuration status of new options and features will always be appended to the end. Demod/ Decoder Config. Program Status Command: Response: <add/DCP_'cr' >add/DCP_'cr' SMT_xxxxxxx'cr' IROT_xxxxx'cr' MOM_xxxxxxx'cr' BERT_xxxx'cr' DT_xxxx'cr' DDT_xxx'cr' RCEN_1_xxxx'cr' RCDR_1_xxxx.x'cr' RCEN_2_xxx'cr' RCEN_3_xxxx'cr' RCDR_3_xxxx.x'cr' RCCP_3_yyy'cr' RCDP_3_yyy'cr' RCEN_4_xxxx'cr' RCDR_4_xxxx.x'cr' RCCP_4_yyy'cr' RCDP_4_yyy'cr' System Modem Type Interface Receive Overhead Type Modem Operation Mode BER Threshold Demodulator Type Demodulator Decoder Type Flex Mux RX Channel #1 Enable Flex Mux RX Channel #1 Data Rate Flex Mux RX Channel #2 Enable Flex Mux RX Channel #3 Enable Flex Mux RX Channel #3 Data Rate Flex Mux RX Channel #3 Clock Phase Flex Mux RX Channel #3 Data Phase Flex Mux RX Channel #4 Enable Flex Mux RX Channel #4 Data Rate Flex Mux RX Channel #4 Clock Phase Flex Mux RX Channel #4 Data Phase Demodulator Frequency Demodulator Rate Descrambler Enable Differential Decoder RF Loopback IF Loopback Sweep Center Frequency Sweep Width Range (Note 1) (Note 2) (Note 1) (Note 1) (Note 3) (Note 3) (Note 3) (Note 1) (Note 4) (Note 4) (Note 4) DF_nnn.nnnnnn'cr' DR_nnnn_mmmm.mmm'cr' DE_xxx'cr' DDEC_xxx'cr' RFL_xxx'cr' IFL_xxx'cr' SCF_snnnnn'cr' SWR_nnnnn'cr' SR_xxx'cr' A–15 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM ILT_xxx'cr' ERF_nnnnn.n'cr' BC_xxx'cr' RCP_xxxx'cr' BBL_xxx'cr' ILB_xxx'cr' ILT_xxx'cr' ICFR_xxxx'cr' IRFS_T1_ssss'cr' IRFS_E1_ssss'cr' IBP_xxx'cr' IRE_xxxxxx'cr' RDF_xxxx'cr' ISCL_RX1_nnn'cr' ISCL_RX2_nnn'cr' RDP_xxxx'cr' IDF_xxxxxx'cr' (Note 5) ICRC_xxx'cr' (Note 5) IBS_nnnnnn'cr' BICA_dd;cc_dd;cc...'cr' (Note 5) DSR_xxx'cr' RSDE_xxx'cr' BW_RX1_nnn'cr' (Note 6) BW_RX2_nnn'cr' (Note 6) BW_RX3_nnn'cr' (Note 6) BW_RX4_nnn'cr' (Note 6) RXDR_xxxxxx'cr' ROBR_nnnnn'cr' (Note 7) RCCL_n'cr' (Note 7) RCSB_n'cr' (Note 7) ROCP_xxxx'cr' (Note 7) RCT_xxxxx'cr' (Note 7) ENSP_nn.n'cr' (Note 8) MAXT_n.n'cr' (Note 8) RDA_xxx'cr' RET_xxxxx'cr' (Note 6) RRSI_xx'cr' R310_xxx'cr''lf'] Sweep Reacquisition Interface Loop Timing External Reference Frequency Buffer Clock Receive Clock Phase Baseband Loopback Interface Loopback Interface Loop Timing Interface Coding Format Receive Interface Receive T1 Frame Structure Interface Receive E1 Frame Structure Interface Buffer Programming Interface Read Error (RX 2047) Receive Data Fault Service Channel Level RX1 Service Channel Level RX2 Receive Data Phase Insert Data Format Insert E1 CRC Enable Interface Buffer Size Bulk Insert Channels Assignment Demodulator Spectrum Rotation Reed-Solomon Decoder Backward Alarm Enable RX1 Backward Alarm Enable RX2 Backward Alarm Enable RX3 Backward Alarm Enable RX4 RX Driver Type ASYNC Receive Overhead Baud Rate ASYNC Receive Channel Character Length ASYNC Receive Channel Stop Bits ASYNC Receive Overhead Channel Parity ASYNC Receive Communications Type AUPC EBN0 Target Set Point AUPC Max. Tracking Rate Receive BPSK Data Ordering IDR Receive ESC Type RX Reed-Solomon Interleave Value RX 8PSK 2/3 IESS-310 Operation This command is used by the Adaptive Boradband M:N protection switch to collect information that is necessary to configure back-up modems. Because this command (content and/or order) can be changed at any time by Adaptive Boradband, it is advisable that other commands ('DCS_' and 'ICS_', or 'BCS_') be used for M&C systems. A–16 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Notes: 1. 2. 3. 4. 5. 6. 7. 8. Interface Config. Status Command: Response: <add/ICS_'cr' >add/ICS_'cr' TC_xxxx'cr' ERF_nnnnn.n'cr' TCP_xxxx'cr' RCP_xxxx'cr' BBL_xxx'cr' ILB_xxx'cr' ILT_xxx'cr' ICFT_xxxx'cr' ICFR_xxxx'cr' BC_xxx'cr' IRFS_T1_ssss'cr' IRFS_E1_ssss'cr' IBP_xxx'cr' IBS_nnnnnn'cr' ITOT_xxxxx'cr' IROT_xxxxx'cr' ISP_xxxxxx'cr' IRE_xxxxxx'cr' TDF_xxxx'cr' RDF_xxxx'cr' ISCL_TX1_nnn'cr' ISCL_TX2_nnn'cr' ISCL_RX1_nnn'cr' ISCL_RX2_nnn'cr' TDP_xxxx'cr' RDP_xxxx'cr' DDF_xxxxxx'cr' (Note 1) BDCA_dd;cc_dd;cc...'cr' (Note 1) ICRC_xxx'cr' (Note 2) IDF_xxxxxx'cr' (Note 2) BICA_dd;cc_dd;cc...'cr' (Note 2) BW_TX1_nnn'cr' (Note 3) BW_TX2_nnn'cr' (Note 3) BW_TX3_nnn'cr' (Note 3) BW_TX4_nnn'cr' (Note 3) BW_RX1_nnn'cr' (Note 4) BW_RX2_nnn'cr' (Note 4) BW_RX3_nnn'cr' (Note 4) BW_RX4_nnn'cr' (Note 4) TXDR_xxxxxx'cr' A–17 Data is only returned if FLEX MUX PCB (Card Slot #1) is installed. Data not returned if Channel #1 is disabled. Data not returned if Channel #3 is disabled or set for AUPC. Data not returned if Channel #4 is disabled or set for AUPC. Data is only returned for RX D&I Overhead (or Flex Mux D&I mode). Data is only returned for RX IDR Overhead. Data is only returned for RX ASYNC Overhead. Data is only returned for RX ASYNC Overhead (or Flex Mux AUPC mode). Transmit Clock (Source) External Reference Frequency Transmit Clock Phase Receive Clock Phase Baseband Loopback Interface Loopback Interface Loop Timing Interface Coding Format Transmit Interface Coding Format Receive Buffer Clock (Source) Interface Receive Frame Structure (T1) Interface Receive Frame Structure (E1) Interface Buffer Programming Interface Buffer Size Interface Transmit Overhead Type Interface Receive Overhead Type Interface Substitution Pattern (TX 2047) Interface Read Error (RX 2047) Transmit Data Fault Receive Data Fault Service Channel Level TX1 Service Channel Level TX2 Service Channel Level RX1 Service Channel Level RX2 Transmit Data Phase Receive Data Phase Drop Data Format Bulk Drop Channels Assignment Insert E1 CRC Enable Insert Data Format Bulk Insert Channels Assignment Backward Alarm Enable TX1 Backward Alarm Enable TX2 Backward Alarm Enable TX3 Backward Alarm Enable TX4 Backward Alarm Enable RX1 Backward Alarm Enable RX2 Backward Alarm Enable RX3 Backward Alarm Enable RX4 TX Driver Type SNM-1002 LinkSync Modem Remote Control Operation RXDR_xxxxxx'cr' TOBR_nnnnn'cr' (Note 5) TCCL_n'cr' (Note 5) TCSB_n'cr' (Note 5) TOCP_xxxx'cr' (Note 5) TCT_xxxxx'cr' (Note 5) ROBR_nnnnn'cr' (Note 6) RCCL_n'cr' (Note 6) RCSB_n'cr' (Note 6) ROCP_xxxx'cr' (Note 6) RCT_xxxxx'cr' (Note 6) LPC_xxx'cr' (Note 5) NOMP_snn.n'cr' (Note 5) MINP_snn.n'cr' (Note 5) MAXP_snn.n'cr' (Note 5) LCL_xxxx'cr' (Note 5) RCL_xxxx'cr' (Note 5) ENSP_nn.n'cr' (Note 6) MAXT_n.n'cr' (Note 6) RTSM_xxx'cr' CTSD_xx'cr' TET_xxxxx'cr' (Note 3) RET_xxxxx'cr' (Note 4) MTDR_1_yyyyyy'cr' MTIT_1_yyyyy'cr' (Note 7) MTCP_1_yyy'cr' (Note 7) MTDP_1_yyy'cr' (Note 7) MTMD_1_yyyyy'cr' MTAF_1_yyy'cr' (Note 7) MTDR_2_yyyyyy'cr' MTIT_2_yyyyy'cr' (Note 7) MTCP_2_yyy'cr' (Note 7) MTDP_2_yyy'cr' (Note 7) MTMD_2_yyyyy'cr' MTAF_2_yyy'cr' (Note 7) MTDR_3_yyyyyy'cr' MTIT_3_yyyyy'cr' (Note 7) MTCP_3_yyy'cr' (Note 7) MTDP_3_yyy'cr' (Note 7) MTMD_3_yyyyy'cr' MTAF_3_yyy'cr' (Note 7) MTDR_4_yyyyyy'cr' MTIT_4_yyyyy'cr' (Note 7) MTCP_4_yyy'cr' (Note 7) MTDP_4_yyy'cr' (Note 7) MTMD_4_yyyyy'cr' MTAF_4_yyy'cr' (Note 7) MTDR_5_yyyyyy'cr' MTIT_5_yyyyy'cr' (Note 7) MTCP_5_yyy'cr' (Note 7) MTDP_5_yyy'cr' (Note 7) MTMD_5_yyyyy'cr' MTAF_5_yyy'cr' (Note 7) MTDR_6_yyyyyy'cr' MTIT_6_yyyyy'cr' (Note 7) MTCP_6_yyy'cr' (Note 7) MTDP_6_yyy'cr' (Note 7) MTMD_6_yyyyy'cr' MTAF_6_yyy'cr' (Note 7) MTDR_7_yyyyyy'cr' Revision 2 MN/SNM1002.OM (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) (Note 7) A–18 RX Driver Type ASYNC Transmit Overhead Baud Rate ASYNC Transmit Channel Character Length ASYNC Transmit Channel Stop Bits ASYNC Transmit Overhead Channel Parity ASYNC Transmit Communications Type ASYNC Receive Overhead Baud Rate ASYNC Receive Channel Character Length ASYNC Receive Channel Stop Bits ASYNC Receive Overhead Channel Parity ASYNC Receive Communications Type AUPC Local Power Enable AUPC Nominal Power Value AUPC Minimum Power Value AUPC Maximum Power Value AUPC Local Carrier Loss AUPC Remote Carrier Loss AUPC EBN0 Target Set Point AUPC Max. Tracking Rate RTS TX-IF Control Mode CTS Delay Time IDR Transmit ESC Type IDR Receive ESC Type Mux Tributary #1 Data Rate & Enable Mux Tributary #1 Interface Type Mux Tributary #1 Clock Phase Mux Tributary #1 Data Phase Mux Tributary #1 Mode Mux Tributary #1 Async Mode Mux Tributary #2 Data Rate & Enable Mux Tributary #2 Interface Type Mux Tributary #2 Clock Phase Mux Tributary #2 Data Phase Mux Tributary #2 Mode Mux Tributary #2 Async Mode Mux Tributary #3 Data Rate & Enable Mux Tributary #3 Interface Type Mux Tributary #3 Clock Phase Mux Tributary #3 Data Phase Mux Tributary #3 Mode Mux Tributary #3 Async Mode Mux Tributary #4 Data Rate & Enable Mux Tributary #4 Interface Type Mux Tributary #4 Clock Phase Mux Tributary #4 Data Phase Mux Tributary #4 Mode Mux Tributary #4 Async Mode Mux Tributary #5 Data Rate & Enable Mux Tributary #5 Interface Type Mux Tributary #5 Clock Phase Mux Tributary #5 Data Phase Mux Tributary #5 Mode Mux Tributary #5 Async Mode Mux Tributary #6 Data Rate & Enable Mux Tributary #6 Interface Type Mux Tributary #6 Clock Phase Mux Tributary #6 Data Phase Mux Tributary #6 Mode Mux Tributary #6 Async Mode Mux Tributary #7 Data Rate & Enable SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM MTIT_7_yyyyy'cr' (Note 7) MTCP_7_yyy'cr' (Note 7) MTDP_7_yyy'cr' (Note 7) MTMD_7_yyyyy'cr' (Note 7) MTAF_7_yyy'cr' (Note 7) MTDR_8_yyyyyy'cr' (Note 7) MTIT_8_yyyyy'cr' (Note 7) MTCP_8_yyy'cr' (Note 7) MTDP_8_yyy'cr' (Note 7) MTMD_8_yyyyy'cr' (Note 7) MTAF_8_yyy'cr' (Note 7) TCEN_1_xxxx'cr' TCDR_1_xxxx.x'cr' TCEN_2_xxx'cr' TCEN_3_xxxx'cr' TCDR_3_xxxx.x'cr' TCCP_3_yyy'cr' TCDP_3_yyy'cr' TCEN_4_xxxx'cr' TCDR_4_xxxx.x'cr' TCCP_4_yyy'cr' TCDP_4_yyy'cr' RCEN_1_xxxx'cr' RCDR_1_xxxx.x'cr' RCEN_2_xxx'cr' RCEN_3_xxxx'cr' RCDR_3_xxxx.x'cr' RCCP_3_yyy'cr' RCDP_3_yyy'cr' RCEN_4_xxxx'cr' RCDR_4_xxxx.x'cr' RCCP_4_yyy'cr' RCDP_4_yyy'cr' (Note 8) (Note 9) (Note 8) (Note 8) (Note 10) (Note 10) (Note 10) (Note 8) (Note 11) (Note 11) (Note 11) (Note 8) (Note 12) (Note 8) (Note 8) (Note 13) (Note 13) (Note 13) (Note 8) (Note 14) (Note 14) (Note 14) 'lf'] Mux Tributary #7 Interface Type Mux Tributary #7 Clock Phase Mux Tributary #7 Data Phase Mux Tributary #7 Mode Mux Tributary #7 Async Mode Mux Tributary #8 Data Rate & Enable Mux Tributary #8 Interface Type Mux Tributary #8 Clock Phase Mux Tributary #8 Data Phase Mux Tributary #8 Mode Mux Tributary #8 Async Mode Flex Mux TX Channel #1 Enable Flex Mux TX Channel #1 Data Rate Flex Mux TX Channel #2 Enable Flex Mux TX Channel #3 Enable Flex Mux TX Channel #3 Data Rate Flex Mux TX Channel #3 Clock Phase Flex Mux TX Channel #3 Data Phase Flex Mux TX Channel #4 Enable Flex Mux TX Channel #4 Data Rate Flex Mux TX Channel #4 Clock Phase Flex Mux TX Channel #4 Data Phase Flex Mux RX Channel #1 Enable Flex Mux RX Channel #1 Data Rate Flex Mux RX Channel #2 Enable Flex Mux RX Channel #3 Enable Flex Mux RX Channel #3 Data Rate Flex Mux RX Channel #3 Clock Phase Flex Mux RX Channel #3 Data Phase Flex Mux RX Channel #4 Enable Flex Mux RX Channel #4 Data Rate Flex Mux RX Channel #4 Clock Phase Flex Mux RX Channel #4 Data Phase The Interface configuration status command causes a block of data to be returned by the addressed MODEM. The block reflects the current configuration of the interface. Additional configuration status of new options and features will always be appended to the end. Notes: 1. Data is only returned for TX D&I Overhead. 2. Data is only returned for RX D&I Overhead. 3. Data is only returned for TX IDR Overhead. 4. Data is only returned for RX IDR Overhead. 5. Data is only returned for TX ASYNC Overhead. 6. Data is only returned for RX ASYNC Overhead. Data is only returned if MUX PCB (Card Slot #1) is installed. 8. Data is only returned if FLEX MUX PCB (Card Slot #1) is installed. 9. Data not returned if TX Channel #1 is disabled. 10. Data not returned if TX Channel #3 is disabled or set for AUPC. 11. Data not returned if TX Channel #4 is disabled or set for AUPC. 12. Data not returned if RX Channel #1 is disabled. A–19 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM 13. Data not returned if RX Channel #3 is disabled or set for AUPC. 14. Data not returned if RX Channel #4 is disabled or set for AUPC. MODEM Faults Status (Summary) Command: Response: Modulator Status Command: Response: Demodulator Status Interface Transmit Side Status Command: Response: Command: Response: <add/MFS_'cr' >add/MFS_'cr' DMD_xxx'cr' MOD_xxx'cr' TX_xxx'cr' IRX_xxx'cr' CEQ_xxx'cr' BWAL_xxx'cr'’lf'] Demodulator (FLT/OK) Modulator (FLT/OK) Interface Transmit Side (FLT/OK) Interface Receive Side (FLT/OK) Common Equipment (FLT/OK) Backward Alarms (FLT/OK) <add/MS_'cr' >add/MS_'cr' RF_xxx'cr' MOD_xxx'cr' SYN_xxx'cr' DCS_xxx'cr' ICH_xxx'cr' QCH_xxx'cr' AGC_xxx'cr' SCT_xxx'cr' EXT_xxx'cr' CONF_xxx'cr' SFLT_xx'cr''lf'] RF Output (ON/OFF) actual status not config Module (OK/FLT) IF Synthesizer (OK/FLT) Data Clock Synthesizer (OK/FLT) I Channel (OK/FLT) Q Channel (OK/FLT) AGC Level (OK/FLT) Modem Reference PLL Lock (OK/FLT) Modem Reference Activity (OK/FLT) Configuration (OK/FLT) Number of stored faults logged (0 to 10) <add/DS_'cr' >add/DS_'cr' MOD_xxx'cr' CD_xxx'cr' SYN_xxx'cr' ICH_xxx'cr' QCH_xxx'cr' BERT_xxx'cr' CONF_xxx'cr' SFLT_xx'cr''lf'] Demod Module (OK/FLT) Carrier Detect (OK/FLT) IF Synthesizer Lock (OK/FLT) I Channel (OK/FLT) Q Channel (OK/FLT) BER Threshold (OK/FLT) Configuration (OK/FLT) Number of stored faults logged (0 to 10) <add/ITXS_'cr' >add/ITXS_'cr' DRP_xxx'cr' TXD_xxx'cr' PLL_xxx'cr' CLK_xxx'cr' TAC1_xxx'cr' TAC2_xxx'cr' CONF_xxx'cr' SFLT_xx'cr''lf'] D&I Drop (OK/FLT) Transmit Data/AIS (OK/FLT) Transmit Synthesizer PLL Lock (OK/FLT) Selected Transmit Clock Activity (OK/FLT) Transmit Audio Clip Channel #1 (OK/FLT) Transmit Audio Clip Channel #2 (OK/FLT) Configuration (OK/FLT) Number of Stored Faults Logged (0 to 10) A–20 SNM-1002 LinkSync Modem Remote Control Operation Interface Receive Side Status Command: Response: Common Equipment Status Command: Response: Revision 2 MN/SNM1002.OM <add/IRXS_'cr' >add/IRXS_'cr' UNFL_xxx'cr' OVFL_xxx'cr' RXD_xxx'cr' FBER_xxx'cr' BWA_xxx'cr' CLK_xxx'cr' PLL_xxx'cr' DMUX_xxx'cr' 2047_xxx'cr' BUFF_xxx'cr' INS_xxx'cr' RAC1_xxx'cr' RAC2_xxx'cr' CONF_xxx'cr' SFLT_xx'cr''lf'] Buffer Underflow (OK/FLT) Buffer Overflow (OK/FLT) Receive Data Loss/AIS (OK/FLT) Frame BER (OK/FLT) Receive Backward Alarm (OK/FLT) Selected Buffer Clock Activity (OK/FLT) Buffer Clock PLL Lock (OK/FLT) Demux Lock (OK/FLT) 2047 Pattern Lock Detect (OK/FLT) Buffer Full (OK/FLT) D&I Insert (OK/FLT) Receive Audio Clip Channel #1 (OK/FLT) Receive Audio Clip Channel #2 (OK/FLT) Configuration (OK/FLT) Number of Stored Faults Logged (0 to 10) <add/CES_'cr' >add/CES_' M&C_xxx'cr' INT_xxx'cr' BAT_xxx'cr' +5_xxx'cr' +12_xxx'cr' -12_xxx'cr' ST_xxx'cr' MODE_xxxxxx'cr' SFLT_xx'cr''lf'] Monitor & Control Module (OK/FLT) Data Interface/Overhead Module (OK/FLT) Battery/Clock (OK/FLT) +5V Power Supply (OK/FLT) +12V Power Supply (OK/FLT) -12V Power Supply (OK/FLT) Self Test (OK/FLT) Mode (LOCAL or REMOTE) Number of stored faults logged (0 to 10) The common equipment status command causes a block of data to be returned which indicates the status of the common equipment. A.4.1 Raw BER Error Performance Command: Response: <add/RBER_'cr' >add/RBER_xm.mE-ee'cr''lf'] Where: x = < or > (data modifier to indicate that the error rate is less than or greater than the returned value). m.m = 1.0 to 9.9 (error rate mantissa). ee = 1 to 99 (error rate exponent). Notes: 1. The 'x' (< or >) parameter is only returned if the error rate has exceeded the computational resolution of the system. 2. 'No Data' is returned if the error rate cannot be calculated. 3. 'Sampling' is returned if not enough data is currently available to calculate the error rate. A–21 SNM-1002 LinkSync Modem Remote Control Operation Corrected BER Command: Response: Revision 2 MN/SNM1002.OM <add/CBER_'cr' >add/CBER_xm.mE-ee'cr''lf'] Where: x = < or > (data modifier to indicate that the error rate is less than or greater than the returned value). m.m = 1.0 to 9.9 (error rate mantissa). ee = 1 to 99 (error rate exponent). Notes: 1. The 'x' (< or >) parameter is only returned if the error rate has exceeded the computational resolution of the system. 2. 'No Data' is returned if the error rate cannot be calculated. 3. 'Sampling' is returned if not enough data is currently available to calculate the error rate. Corrected BER Log Command: Response: Examples: <add/CBEL_'cr' >add/CBEL_t.t;s1,s2,s3 ... sn'cr''lf'] [No new compiled data from last poll] >add/CBEL_1.0'cr''lf'] Where: t.t = Time between corrected BER samples in seconds ('0.1' to '9.9'). ; = At least one data point has been logged. [Momentary lock in 32 time intervals: 2.0E-3, 5.2E-7, 1.0E-10, <1.0E-12] s1 to sn = Corrected BER samples in the format of (xmmee). >add/CBEL_1.0;,,,,,,,2003,5207,101 0,<1012,,,,,,,,,,,,,,,,,,,,,'cr''lf'] x = The optional data modifier '<' or '>' (less than or greater than). mm = The corrected BER mantissa ('10' for 1.0 to '99 for 9.9). ee = The corrected BER negative exponent ('00' to '99'). Error data (samples) are compiled at the nominal system rate indicated by the time parameter (t.t). The samples are stored in a thirty-two-element FIFO. When the 'CBEL_' command is received, the samples in the FIFO are formatted and returned as indicated. The FIFO is then flushed. If the FIFO becomes full, the oldest sample will be lost as the current sample is written. Notes: 1. The most recent sample is represented by 'sn' while the least recent sample is represented by 's1'. 2. Data delimited by a comma (',') will be returned for all time intervals logged. 3. The optional data modifiers '>' and '<' are only present if the error rate exceeds the computational resolution of the system. A–22 SNM-1002 LinkSync Modem Remote Control Operation Interface Read Error Status Command: Response: Revision 2 MN/SNM1002.OM <add/IRES_'cr' >add/IRES_tttt_xn.nE-ee'cr''lf'] Where: tttt = FRM (FRAME) or 2047 (indicates type of error being read). x = < or > (data modifier to indicate that the error rate is less than or greater than the returned value). m.m = 1.0 to 9.9 (error rate mantissa). ee = 1 to 99 (error rate exponent). This command returns frame or 2047 error rate. The 'IRE_' configuration command is used to select reading of frame or 2047 errors. Notes: 1. The 'x' (< or >) parameter is only returned if the error rate has exceeded the computational resolution of the system. 2. 'No Data' is returned if the error rate cannot be calculated. 3. 'Sampling' is returned if not enough data is currently available to calculate the error rate. Eb/N0 Status Command: Response: Where: <add/EBN0_'cr' >add/EBN0_xnn.ndB'cr''lf'] x = < or > (data modifier to indicate that the Eb/N0 is less than or greater than the returned value). nn.n = 1.0 to 99.9 (Eb/N0 value). Notes: 1. The 'x' (< or >) parameter is only returned if the Eb/N0 has exceeded the computational resolution of the system. 2. 'No Data' is returned if the Eb/N0 cannot be calculated. 3. 'Sampling' is returned if not enough data is currently available to calculate the Eb/N0. Modulator Rate Status Command: Response: <add/MR_'cr' >add/MR_nnnn_mmmm.mmm'cr''lf'] Where: nnnn = 1/2 (QPSK 1/2), [coder rate], 3/4 (QPSK 3/4), 7/8 (QPSK 7/8), BP12 (BPSK 1/2), 8P23 (8PSK 2/3). mmmm.mmm = Data rate in kHz. Demodulat or Rate Status Command: Response: <add/DR_'cr' >add/DR_nnnn_mmmm.mmm'cr''lf'] Where: nnnn = 1/2 (QPSK 1/2), [decoder rate], 3/4 (QPSK 3/4), 7/8 (QPSK 7/8), BP12 (BPSK 1/2), 8P23 (8PSK 2/3). mmmm.mmm = Data rate in kHz. A–23 SNM-1002 LinkSync Modem Remote Control Operation Receive Signal Level Status Command: Response: Revision 2 MN/SNM1002.OM <add/RSL_'cr' >add/RSL_xsnn.ndBm'cr''lf'] Where: x = < or > (data modifier to indicate that the receive signal level is less than or greater than the returned value). s = + or - (receive signal level sign, plus or minus). nn.n = 0.0 to 99.9 (receive signal level magnitude). Notes: 1. The 'x' (< or >) parameter is only returned if the level has exceeded the computational resolution of the system. 2. 'No Data' is returned if the level cannot be calculated. 3. Sampling' is returned if not enough data is currently available to calculate the level. Interface Buffer Fill Status Current Sweep Value Command: Response: <add/IBFS_'cr' >add/IBFS_nn%'cr''lf'] Where: nn = 1 to 99 (relative to buffer depth). Command: Response: <add/CSV_'cr' >add/CSV_xsnnnnn'cr''lf] Where: x = < or > (data modifier to indicate that the sweep offset value is less than or greater than the returned value). s = + or - (sweep offset from center). nnnnn = 0 to 35000. yyy = OK or FLT (decoder lock status OK or FAULT). Notes: 1. The 'x' (< or >) parameter is only returned if the level has exceeded the computational resolution of the system. 2. 'No Data' is returned if the level cannot be calculated. 3. 'Sampling' is returned if not enough data is currently available to calculate the level. A–24 SNM-1002 LinkSync Modem Remote Control Operation A.5 Revision 2 MN/SNM1002.OM Stored Faults Information on stored faults is returned when requested. If no stored fault exists for a given fault number, the words “NO Fault” will be returned instead of the normal time/date status information. The following symbols are commonly used to define the stored faults status commands: • • • • • • • # hh mm ss MM DD YYYY Modulator Stored Faults Command: Response: Demodulator Stored Faults Command: Response: Interface Transmit Side Stored Faults Command: Response: Fault number (0 to 9). “0” is the first fault stored. Hours in 24-hr. format. Minutes. Seconds. Month. Day. Year. <add/MSF_#'cr' >add/MSF_# hh:mm:ss MM/DD/YYYYY'cr' MOD_xxx'cr' SYN_xxx'cr' DCS_xxx'cr' ICH_xxx'cr' QCH_xxx'cr' AGC_xxx'cr' SCT_xxx'cr' EXT_xxx'cr' CONF_xxx'cr''lf'] Module (OK/FLT) IF Synthesizer (OK/FLT) Data Clock Synthesizer (OK/FLT) I Channel (OK/FLT) Q Channel (OK/FLT) AGC Level (OK/FLT) Modem Reference PLL Lock (OK/FLT) Modem Reference Activity (OK/FLT) Configuration (OK/FLT) <add/DSF_#'cr' >add/DSF_# hh:mm:ss MM/DD/YYYY'cr' MOD_xxx'cr' CD_xxx'cr' SYN_xxx'cr' ICH_xxx'cr' QCH_xxx'cr' BERT_xxx'cr' CONF_xxx'cr''lf'] Demod Module (OK/FLT) Carrier Detect (OK/FLT) IF Synthesizer Lock (OK/FLT) I Channel (OK/FLT) Q Channel (OK/FLT) BER Threshold (OK/FLT) Configuration (OK/FLT) <add/ITSF_#'cr' >add/ITSF_# hh:mm:ss MM/DD/YYYY'cr' DRP_xxx'cr' TXD_xxx'cr' PLL_xxx'cr' CLK_xxx'cr' TAC1_xxx'cr' TAC2_xxx'cr' CONF_xxx'cr''lf'] D&I Drop (OK/FLT) Transmit Data/AIS (OK/FLT) Transmit Synthesizer PLL Lock (OK/FLT) Selected Transmit Clock Activity (OK/FLT) Transmit Audio Clip Channel #1 (OK/FLT) Transmit Audio Clip Channel #2 (OK/FLT) Configuration (OK/FLT) A–25 SNM-1002 LinkSync Modem Remote Control Operation Interface Receive Side Stored Faults Command: Response: Common Equipment Stored Faults Command: Response: Revision 2 MN/SNM1002.OM <add/IRSF_#'cr' >add/IRSF_# hh:mm:ss MM/DD/YYYY'cr' UNFL_xxx'cr' OVFL_xxx'cr' RXD_xxx'cr' FBER_xxx'cr' BWA_xxx'cr' CLK_xxx'cr' PLL_xxx'cr' DMUX_xxx'cr' 2047_xxx'cr' BUFF_xxx'cr' INS_xxx'cr' RAC1_xxx'cr' RAC2_xxx'cr' CONF_xxx'cr''lf'] Buffer Underflow (OK/FLT) Buffer Overflow (OK/FLT) Receive Data Loss/AIS (OK/FLT) Frame BER (OK/FLT) Receive Backward Alarm (OK/FLT) Selected Buffer Clock Activity (OK/FLT) Buffer Clock PLL Lock (OK/FLT) Demux Lock (OK/FLT) 2047 Pattern Lock Detect (OK/FLT) Buffer Full (OK/FLT) D&I Insert (OK/FLT) Receive Audio Clip Channel #1 (OK/FLT) Receive Audio Clip Channel #2 (OK/FLT) Configuration (OK/FLT) <add/CSF_#'cr' >add/CSF_# hh:mm:ss MM/DD/YYYY'cr' M&C_xxx'cr' INT_xxx'cr' BAT_xxx'cr' +5_xxx'cr' +12_xxx'cr' -12_xxx'cr' ST_xxx'cr''lf'] Monitor & Control Module (OK/FLT) Data Interface/Overhead Module (OK/FLT) Battery/Clock (OK/FLT) +5V Power Supply (OK/FLT) +12V Power Supply (OK/FLT) -12V Power Supply (OK/FLT) Self Test (OK/FLT) A–26 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Bulk Command: <add/BCAS_'cr' Consol. Response: >add/BCAS_p1,p2,p3, . . . pn'cr''lf'] Analog Status Where 'pn' is the last parameter returned. This command is similar to the 'BCS_' command, but returns modem analog parameters. Additional status of new options and features will always be appended to the end. Parameter Number 1 Parameter Name (Command Reference) Receive Signal Level (ref. 'RSL_' command). 2 Raw BER (ref. 'RBER_' command). p2 = xm.mE-ee. 3 Corrected BER (ref. 'CBER_' command). p3 = xm.mE-ee. 4 Interface Read Error Status (ref. 'IRES_' command). p4 = tttt_xm.mE-ee. 5 EB/N0 (ref. 'EBN0_' command). p5 = xnn.n, EB/N0 in dB. 6 Buffer Fill Status (ref. 'IBFS_' command). p6 = nn%, buffer fill status. Description p1 = xsnn.n, receive signal level in dBm. Note: Parameters 2 through 6 are dependent on carrier acquisition, if the decoder is not locked empty data blocks are returned (,,,,,). Bulk Consol. Status Command: Response: <add/BCS_'cr' >add/BCS_p1,p2,p3, . . . pn'cr''lf'] Where 'pn' is the last parameter returned. A–27 This command causes bulk modem status to be returned. To reduce the length of the response, message parameter data are returned without identifiers. However, parameter identification can be determined by order of return. Each status parameter is terminated with a ',' (comma) except for the last parameter which has the standard message termination sequence ('cr''lf']). Most of the data returned is formatted the same way as the single command status request (refer to the appropriate portions of this document in preceding sections). Additional configuration status of new options and features will always be appended to the end. SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Parameter Number 1 Parameter Name (Command Reference) Modulator RF output (ref. 'RF_' command). 2 Modulator IF frequency (ref. 'MF_' command). p2 = nnn.nnnnnn, IF frequency in MHz. 3 Modulator rate (ref. 'MR_' command). p3 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 4 Modulator preset 'A' assignment (ref. 'ARMA_' command). p4 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 5 Modulator preset 'B' assignment (ref. 'ARMB_' command). p5 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 6 Modulator preset 'C' assignment (ref. 'ARMC_' command). p6 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 7 Modulator preset 'D' (ref. 'ARMD_' command). p7 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 8 Modulator preset 'V' assignment (ref. 'ARMV_' command). p8 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 9 Modulator power offset (ref. 'MPO_' command). p9 = snn.n, modulator power offset in dB. 10 Modulator output power level (ref. 'MOP_' command). p10 = snn.n, transmitter output power level in dBm. 11 Scrambler enable (ref. 'SE_' command). p11 = n, where 'n' is '0' (off) or '1' (on). 12 Differential encoder enable (ref. 'DENC_' command). p12 = n, where 'n' is '0' (off) or '1' (on). 13 Modulator type (ref. 'MT_' command). p13 = n, where 'n' is '0' (EFD), '1' (INTL), '3' (FDC), '4' (CSC), or '6' (SDM51). 14 Modulator encoder type (ref. 'MET_' command). p14 = n, where 'n' is '0' ( SEQ), '1' (VIT). 15 Carrier only mode ON/OFF. p15 = n, where 'n' is '0' (off) or '1' (on). 16 Demodulator IF (ref. 'DF_' command). p16 = nnn.nnnnnn, demodulator IF frequency in MHz. Description p1 = n, where 'n' is '0' (off) or '1' (on). A–28 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Bulk Consol. Status (continued) Parameter Number 17 Parameter Name (Command Reference) Demodulator rate (ref. 'DR_' command). 18 Demodulator preset A (ref. 'ADRA_' command). p18 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 19 Demodulator preset B assignment (ref. 'ADRB_' command). p19 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 20 Demodulator preset C assignment (ref. 'ADRC_' command). p20 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 21 Demodulator preset D assignment (ref. 'ADRD_' command). p21 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 22 Demodulator preset V assignment (ref. 'ADRV_' command). p22 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. 23 Descrambler enable (ref. 'DE_' command). p23 = n, where 'n' is '0' (off) or '1' (on). 24 Differential decoder (ref. 'DDEC_' command). p24 = n, where 'n' is '0' (off) or '1' (on). 25 RF loopback (ref. 'RFL_' command). p25 = n, where 'n' is '0' (off) or '1' (on). 26 IF loopback (ref. 'IFL_' command). p26 = n, where 'n' is '0' (off) or '1' (on). 27 Sweep center frequency (ref. 'SCF_' command). p27 = snnnnn, sweep center frequency in Hertz. 28 Sweep width range (ref. 'SWR_' command). p28 = nnnnn, sweep range in Hertz. 29 Sweep reacquisition (ref. 'SR_' command). p29 = nnn, reacquisition time in seconds. 30 BER threshold (ref. 'BERT_' command). p30 = xxxx, BER threshold. 31 Demodulator type (ref. 'DT_' command). p31 = n, where 'n' is '0' (EFD), '1' (INTL), '3' (FDC), or '4' (CSC). 32 Demodulator decoder type (ref. 'DDT_' command). p32 = n, where 'n' is '0' (SEQ), '1' (VIT). 33 34 Description p17 = nnnn_mmmm.mmm, code rate/data rate in kbit/s. p33 = n, where 'n' is '0' (INT), '1' (REF), '2' (EXT), or 6 (DATA). Transmit clock source (ref. 'TC_' command). p34 = nnnnn.n, external reference frequency in kHz. External reference frequency (ref. 'ERF_' command). A–29 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Bulk Consol. Status (continued) Parameter Number 35 Parameter Name (Command Reference) Transmit clock phase (ref. 'TCP_' command). 36 Receive clock phase (ref. 'RCP_' command). p36 = n, where 'n' is '0' (NRM), '1' (INV). 37 Baseband loopback ref. 'BBL_' command). p37 = n, where 'n' is '0' (off) or '1' (on). 38 Interface loopback (ref. 'ILB_' command). p38 = n, where 'n' is '0' (off) or '1' (on). 39 Interface loop timing (ref. 'ILT_' command). p39 = n, where 'n' is '0' (off) or '1' (on). 40 TX Interface coding format (ref. 'ICFT_' command). p40 = n, where 'n' is '0' (AMI), '2' (B8ZS), or '3' (HDB3). 41 RX Interface coding format (ref. 'ICFR_' command). p41 = n, where 'n' is '0' (AMI), '2' (B8ZS), or '3' (HDB3). 42 Buffer clock source (ref. 'BC_' command). p42 = n, where 'n' is '0' (INT), '1' (REF), '2' (EXT), '3' (SAT), '5' (INS). 43 Interface RX-T1 frame structure (ref. 'IRFS_' command). p43 = n, where n is '0' (NONE) or '1' (G704). 44 reserved null field. 45 Interface RX-E1 frame structure (ref. 'IRFS_' command). 46 reserved null field. 47 Interface Buffer Programming (ref. 'IBP_' command). p47 = n, where 'n' is '0' (BITS) or '1' (MS). 48 Interface buffer size (ref. 'IBS_' command). p48 = nnnnnn, buffer size in bits or milli seconds. 49 Interface transmit overhead type (ref. 'ITOT_' command). p49 = n, where 'n' is '0' (NONE), '1' (IDR), '2' (IBS), '3' (DI), '4' (ASYNC). 50 Interface receive overhead type (ref. 'IROT_' command). p50 = n, where 'n' is '0' (NONE), '1' (IDR), '2' (IBS), '3' (DI), '4' (ASYNC). 51 52 Description p35 = n, where 'n' is '0' (NRM), '1' (INV), '2' (AUTO). p45 = n, where n is '0' (NONE) or '1' (G704). p51 = n, where 'n' is '0' (OFF) or '1' (ON). Interface substitution pattern (ref. 'ISP_' command). p52 = n, where 'n' is '0' (OFF) or '1' (ON). Interface read error (ref. 'IRE_' command). A–30 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Bulk Consol. Status (continued) Parameter Number 53 Parameter Name (Command Reference) Transmit data fault (ref. 'TDF_' command). 54 Receive data fault (ref. 'RDF_' command). p54 = n, where 'n' is '0' (NONE), '1' (DATA), or '2' (AIS). 55 Interface service channel TX1 (ref. 'ISCL_' command). p55 = nnn, service channel level in dBm. 56 Interface service channel TX2 (ref. 'ISCL_' command). p56 = nnn, service channel level in dBm. 57 Interface service channel RX1 (ref. 'ISCL_' command). p57 = nnn, service channel level in dBm. 58 Interface service channel RX2 (ref. 'ISCL_' command). p58 = nnn, service channel level in dBm. 59 System modem type (ref. 'SMT_' command). p59 = n, where 'n' is '0' (IDR), '1' (IBS), ''2' (EFD), 3' (CUSTOM), '4' (DI), or '5' (ASYNC). 60 Modem operation mode (ref. 'MOM_' command). p60 = n, where 'n' is '1' (TX_ONLY), '2' (RX_ONLY), '3' (DUPLEX). 61 MODEM REMOTE/LOCAL mode. p61 = n, where 'n' is '0' (LOCAL), '1' (REMOTE). 62 Transmit data phase (ref. 'TDP_' command). p62 = n, where 'n' is '0' (NRM), '1' (INV). 63 Receive data phase (ref. 'RDP_' command). p63 = n, where 'n' is '0' (NRM), '1' (INV). (Note 1) 64 Drop Data Format (ref. 'DDF_' command). p64 = n, where 'n' is '0' (T1), '1' (T1ESF), '2' (E1CCS), '3' (E1CAS), '6' (E131TS), '7' (T1S), and '8' (T1ESFS). (Note 2) 65 Insert Data Format (ref. 'IDF_' command). p65 = n, where 'n' is '0' (T1), '1' (T1ESF), '2' (E1CCS), '3' (E1CAS), '6' (E131TS), '7' (T1S), and '8' (T1ESFS). (Note 1) 66 Bulk Drop Channels Assignment. p66 = dd;cc_dd;cc_dd;cc_dd;cc......, as defined by the BDCA_ command. (Note 2) 67 Bulk Insert Channels Assignment. p67 = ii;cc_ii;cc_ii;cc_ii;cc......, as defined by the BICA_ command. (Note 2) 68 Insert E1 CRC Enable (ref. 'ICRC_' command). p68 = n, where 'n' is '0' (off) or '1' (on). 69 70 Description p53 = n, where 'n' is '0' (NONE), '1' (DATA), or '2' (AIS). p69 = n, where 'n' is '0' (INT), '1' (EXT1), '2' (EXT5), '3' (EXT10), or '4' (EXT20), respectively. Modem Reference Clock (ref. 'MRC_' command). p70 = n, where 'n' is '0' (NRM), '1' (INV). Modulator Spectrum Rotation (ref. 'MSR_' command). A–31 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Bulk Consol. Status (continued) Parameter Number 71 Parameter Name (Command Reference) Demodulator Spectrum Rotation (ref. 'DSR_' command). 72 Reed-Solomon Encoder Enable (ref. 'RSEN_' command). p72 = n, where 'n' is '0' (off) or '1' (on). 73 Reed-Solomon Decoder Enable (ref. 'RSDE_' command). p73 = n, where 'n' is '0'(OFF), '1' (ON), '2' (CORR_OFF). (Note 3) 74 Backward Alarm enable TX1 (ref. 'BW_TX1_' command). p74 = n, where 'n' is '0' (off) or '1' (on). (Note 3) 75 Backward Alarm enable TX2 (ref. 'BW_TX2_' command). p75 = n, where 'n' is '0' (off) or '1' (on). (Note 3) 76 Backward Alarm enable (ref. 'BW_TX3_' command). p76 = n, where 'n' is '0' (off) or '1' (on). (Note 3) 77 Backward Alarm enable TX4 (ref. 'BW_TX4_' command). p77 = n, where 'n' is '0' (off) or '1' (on). (Note 4) 78 Backward Alarm enable RX1 (ref. 'BW_RX1_' command). p78 = n, where 'n' is '0' (off) or '1' (on). (Note 4) 79 Backward Alarm enable RX2 (ref. 'BW_RX2_' command). p79 = n, where 'n' is '0' (off) or '1' (on). (Note 4) 80 Backward Alarm enable RX3 (ref. 'BW_RX3_' command). p80 = n, where 'n' is '0' (off) or '1' (on). (Note 4) 81 Backward Alarm enable RX4 (ref. 'BW_RX4_' command). p81 = n, where 'n' is '0' (off) or '1' (on). 82 TX Driver Type (ref. 'TXDR_' command). p82 = n, where 'n' is '0' (G.703), '1' (V.35), '2' (RS422), or '3' (RS232). 83 RX Driver Type (ref. 'RXDR_' command). p83 = n, where 'n' is '0' (G.703), '1' (V.35), '2' (RS422), or '3' (RS232). 84 reserved null field. (Note 5) 85 ASYNC TX Overhead Baud Rate (ref. 'TOBR_' command). p85 = nnnnn, where 'nnnnn' is the currently programmed baud rate. (Note 6) 86 ASYNC RX Overhead Baud Rate (ref. 'ROBR_' command). p86 = nnnnn, where 'nnnnn' is the currently programmed baud rate. (Note 5) 87 (Note 6) 88 ASYNC TX Channel Char. Length (ref. 'TCCL_' command). ASYNC RX Channel Char. Length (ref. 'RCCL_' command). A–32 Description p71 = n, where 'n' is '0' (NRM), '1' (INV). p87 = n, where 'n' is the currently programmed character length. p88 = n, where 'n' is the currently programmed character length. SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Bulk Consol. Status (continued) (Note 5) Parameter Number 89 Parameter Name (Command Reference) ASYNC TX Channel Stop (ref. 'TCSB_' command). Description p89 = n, where 'n' is the current number of stop bits programmed. (Note 6) 90 ASYNC RX Channel Stop Bits (ref. 'RCSB_' command). p90 = n, where 'n' is the current number of stop bits programmed. (Note 5) 91 ASYNC TX Channel Parity (ref. 'TOCP_' command). p91 = xxxx, where 'xxxx' is the currently programmed parity. (Note 6) 92 ASYNC RX Channel Parity (ref. 'ROCP_' command). p92 = xxxx, where 'xxxx' is the currently programmed parity. (Note 5) 93 ASYNC TX Communications Type (ref. 'TCT_' command). p93 = n, where 'n' is '0' (RS232), '1' (RS485_4WIRE), '2' (RS485_2WIRE). (Note 6) 94 ASYNC RX Communications Type (ref. 'RCT_' command). p94 = n, where 'n' is '0' (RS232), '1' (RS485). (Note 14) 95 AUPC Local Power enable ON/OFF (ref. 'LPC_' command). p95 = n, where 'n' is '0' (off) or '1' (on). (Note 14) 96 AUPC Nominal Power Value (ref. 'NOMP_' command). p96 = snn.n, where 'snn.n' Nominal Power Value in dBm. (Note 14) 97 AUPC Minimum Power Value (ref. 'MINP_' command). p97 = snn.n, where 'snn.n' Minimum Power Value in dBm. (Note 14) 98 AUPC Maximum Power Value (ref. 'MAXP_' command). p98 = snn.n, where 'snn.n' Maximum Power Value in dBm. (Note 15) 99 AUPC EBN0 Target Set Point (ref. 'ENSP_' command). p99 = nn.n, where 'nn.n' EBN0 Target Set Point in dB. (Note 15) 100 AUPC Max. Tracking Rate (ref. 'MAXT_' command). p100 = n.n, where 'n.n' is the Max. Tracking Rate in dB/Min. (Note 14) 101 AUPC Local Carrier Loss (ref. 'LCL_' command). p101 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2' (MAXIMUM). (Note 14 102 AUPC Remote Carrier Loss (ref. 'RCL_' command). p102 = n, where 'n' is '0' (HOLD), '1' (NOMINAL), or '2' (MAXIMUM). 103 reserved null field. 104 reserved null field. 105 106 p105 = n, where 'n' is '0' (NRM), '1' (INV). Transmit BPSK Data Ordering (ref. 'TDA_' command). p106 = n, where 'n' is '0' (NRM), '1' (INV). Receive BPSK Data Ordering (ref. 'RDA_' command). A–33 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Bulk Consol. Status (continued) Paramete r Number 107 Parameter Name (Command Reference) Description RTS TX-IF Control Mode (ref. 'RTSM_' command). p107 = n, where 'n' is '0' (off) or '1' (on). 108 CTS Delay Time (ref. 'CTSD_' command). p108 = nn, CTS delay time in seconds. 109 Carrier Only Mode (ref. 'COM_' command). p109 = n, where 'n' is '0' (OFF),'1' (CENTER-CW), '2' (DUAL-CW) ,'3' (OFFSET-CW). (Note 3) 110 IDR TX ESC Type (ref. 'TET_' command). p110 = n, where 'n' is '0' (AUDIO), '1' (DATA). (Note 4) 111 IDR RX ESC Type (ref. 'RET_' command). p111 = n, where 'n' is '0' (AUDIO), '1' (DATA). 112 TX Reed-Solomon Interleave Value (ref. 'TRSI_' command). p112 = nn, Interleave value. 113 RX Reed-Solomon Interleave Value (ref. 'RRSI_' command). p113 = nn, Interleave value. 114 reserved null field. 115 reserved null field. 116 reserved null field. 117 TX 8PSK 2/3 IESS-310 Operation (ref. 'T310_' command). p117 = n, where 'n' is '0' (off) or '1' (on). 118 p118 = n, where 'n' is '0' (off) or '1' (on). (Note 7) 119 RX 8PSK 2/3 IESS-310 Operation (ref. 'R310_' command). (Note (8) 120 Flex Mux Channel #1 Enable (ref. "TCEN_1" command). (Note 7) (Note 7) 121 p119 = n, where 'n' is '0' (Disabled), '1' (D&I), or '2' (for T1/E1) operation. TX Flex Mux Channel #1 Data Rate (ref. "TCDR_1" command). p120 = nnnn.n, where 'nnnn.n' is the data rate in Kbps. TX Flex Mux Channel #2 Enable (ref. "TCEN_2" command). p121 = n, where 'n' is '0' (Disabled), '1' (Enabled). TX Flex Mux Channel #3 Enable (ref. "TCEN_3" command). p122 = n, where 'n' is '0' (Disabled), '1' (Sync RS422), '2' (Async RS422), '3' (Sync RS232), '4' (Async RS232), or '5' (AUPC operation). 122 A–34 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Bulk Consol. Status (continued) Parameter Name (Command Reference) (Note 9) Paramete r Number 123 TX Flex Mux Channel #3 Data Rate (ref. "TCDR_3" command). p123 = nnnn.n, where 'nnnn.n' is the data rate in Kbps. (Note 9) 124 TX Flex Mux Channel #3 Clock Phase (ref. "TCCP_3" command). p124 = n, where 'n' is '0' (Normal) or '1' (Invert). (Note 9) 125 TX Flex Mux Channel #3 Data Phase (ref. "TCDP_3" command). p125 = n, where 'n' is '0' (Normal) or '1' (Invert). (Note 7) 126 TX Flex Mux Channel #4 Enable (ref. "TCEN_4" command). (Note 10) 127 Description TX Flex Mux Channel #4 Data Rate (ref. "TCDR_4" command). TX Flex Mux Channel #4 Clock Phase (ref. "TCCP_4" command). (Note 10) 128 p126 = n, where 'n' is '0' (Disabled), '1' (Sync RS232), '2' (Async RS232), '3' (Async RS485), or '4' (AUPC operation). p127 = nnnn.n, where 'nnnn.n' is the data rate in Kbps. TX Flex Mux Channel #4 Data Phase (ref. "TCDP_4" command). p128 = n, where 'n' is '0' (Normal) or '1' (Invert). RX Flex Mux Channel #1 Enable (ref. "RCEN_1" command). p129 = n, where 'n' is '0' (Normal) or '1' (Invert). RX Flex Mux Channel #1 Data Rate (ref. "RCDR_1" command). p130 = n, where 'n' is '0' (Disabled), '1' (D&I), or '2' (T1/E1 operation). (Note 10) 129 (Note 7) 130 (Note 11) 131 RX Flex Mux Channel #2 Enable (ref. "RCEN_2" command). (Note 7) 132 RX Flex Mux Channel #3 Enable (ref. "RCEN_3" command). (Note 7) 133 RX Flex Mux Channel #3 Data Rate (ref. "RCDR_3" command). p131 = nnnn.n, where 'nnnn.n' is the data rate in Kbps. p132 = n, where 'n' is '0' (Disabled), '1' (Enabled). (Note 12) (Note 12) (Note 12) 134 135 RX Flex Mux Channel #3 Clock Phase (ref. "RCCP_3" command). p133 = n, where 'n' is '0' (Disabled), '1' (Sync RS422), '2' (Async RS422), '3' (Sync RS232), '4' (Async RS232), or '5' (AUPC operation). RX Flex Mux Channel #3 Data Phase (ref. "RCDP_3" command). p134 = nnnn.n, where 'nnnn.n' is the data rate in Kbps. RX Flex Mux Channel #4 Enable (ref. "RCEN_4" command). p135 = n, where 'n' is '0' (Normal) or '1' (Invert). RX Flex Mux Channel #4 Data Rate (ref. "RCDR_4" command). p136 = n, where 'n' is '0' (Normal) or '1' (Invert). 136 (Note 7) 137 (Note 13) 138 (Note 13) 139 RX Flex Mux Channel #4 Clock Phase (ref. "RCCP_4" command). RX Flex Mux Channel #4 Data Phase (ref. "RCDP_4" command). p137 = n, where 'n' is '0' (Disabled), '1' (Sync RS232), '2' (Async RS232), '3' (Async RS485), or '4' (AUPC operation). p138 = nnnn.n, where 'nnnn.n' is the data rate in Kbps. A–35 SNM-1002 LinkSync Modem Remote Control Operation (Note 13) Revision 2 MN/SNM1002.OM 140 p139 = n, where 'n' is '0' (Normal) or '1' (Invert). p140 = n, where 'n' is '0' (Normal) or '1' (Invert). Bulk Consol. Status (continued) Notes: 1. Data will only be returned if TX Overhead is programmed for Drop & Insert. Comma is always returned. 2. Data will only be returned if RX Overhead is programmed for Drop & Insert. Comma is always returned. 3. Data will only be returned if TX Overhead is programmed for IDR. Comma is always returned. 4. Data will only be returned if RX Overhead is programmed for IDR. Comma is always returned. 5. Data will only be returned if TX Overhead is programmed for ASYNC. Comma is always returned. 6. Data will only be returned if RX Overhead is programmed for ASYNC. Comma is always returned. 7. Data is only returned if FLEX MUX PCB (Card Slot #1) is installed. Comma is always returned. 8. Data not returned if TX Channel #1 is disabled. Comma is always returned. 9. Data not returned if TX Channel #3 is disabled or set for AUPC. Comma is always returned. 10. Data not returned if TX Channel #4 is disabled or set for AUPC. Comma is always returned. 11. Data not returned if RX Channel #1 is disabled. Comma is always returned. 12. Data not returned if RX Channel #3 is disabled or set for AUPC. Comma is always returned. 13. Data not returned if RX Channel #4 is disabled or set for AUPC. Comma is always returned (except for last parameter). 14. Data will only be returned if TX Overhead is programmed for ASYNC. (or TX Flex Mux AUPC). Comma is always returned. 15. Data will only be returned if RX Overhead is programmed for ASYNC. (or RX Flex Mux AUPC). Comma is always returned. A–36 SNM-1002 LinkSync Modem Remote Control Operation Bulk Consolidated Status Faults Command: Response: Revision 2 MN/SNM1002.OM <add/BCSF_'cr' >add/BCSF_abcdefghijklmnopq r'cr''lf'] This command causes all modem fault status to be returned. To reduce the length of the response, fault status is embedded into the bit structure of the characters that are returned. Faults are indicated by a binary 1 in the designated bit position. Character 'a': Modulator fault status character 1. Bit 6 = 1 always. Bit 5 = Modulator module fault. Bit 4 = RF output status, actual not programmed status (1 = on, 0 = off). Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of modulator stored faults. Character 'b': Modulator fault status character 2. Bit 6 = 1 always. Bit 5 = IF Synthesizer. Bit 4 = reserved. Bit 5 = Data Clock Synthesizer. Bit 2 = I Channel. Bit 1 = Q Channel. Bit 0 = AGC Level. Character 'c': Modulator fault status character 3. Bit 6 = 1 always. Bit 5 = Modem Reference PLL Lock. Bit 4 = reserved. Bit 3 = Configuration. Bit 2 = Modem Reference Activity. Bit 1 = reserved. Bit 0 = reserved. Character 'd': Demodulator fault status character 1. Bit 6 = 1 always. Bit 5 = Demod module fault. Bit 4 = Carrier detect status (0 for decoder lock). Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of demodulator stored faults. Character 'e': Demodulator fault status character 2. Bit 6 = 1 always. Bit 5 = IF Synthesizer Lock. Bit 4 = reserved. Bit 3 = I Channel. Bit 2 = Q Channel. Bit 1 = reserved. Bit 0 = BER threshold. Character 'f': Demodulator fault status character 3. Bit 6 = 1 always. Bit 5 = reserved. Bit 4 = Configuration. Bit 3 = reserved. Bit 2 = reserved. Bit 1 = reserved. Bit 0 = reserved. A–37 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Character 'g': Interface transmit side faults character 1. Bit 6 = 1 always. Bit 5 = reserved. Bit 4 = reserved. Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of interface transmit side stored faults. Character 'h': Interface transmit side faults character 2. Bit 6 = 1 always. Bit 5 = Transmit Data/AIS. Bit 4 = Transmit Synthesizer PLL Lock. Bit 3 = Selected Transmit Clock Activity. Bit 2 = reserved. Bit 1 = Configuration. Bit 0 = Drop fault. Character 'i': Interface transmit side faults character 3. Bit 6 = 1 always. Bit 5 = TX Audio Channel 1 Clip. Bit 4 = TX Audio Channel 2 Clip. Bit 3 = reserved. Bit 2 = reserved. Bit 1 = reserved. Bit 0 = reserved. Character 'j': Interface receive side faults character 1. Bit 6 = 1 always. Bit 5 = Insert fault. Bit 4 = reserved. Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of interface receive side stored faults. Character 'k': Interface receive side faults character 2. Bit 6 = 1 always. Bit 5 = Buffer Underflow. Bit 4 = Buffer Overflow. Bit 3 = Receive Data Loss/AIS. Bit 2 = Frame BER. Bit 1 = Receive Backward Alarm. Bit 0 = Selected Buffer Clock Activity. Character 'l': Interface receive side faults character 3. Bit 6 = 1 always. Bit 5 = Buffer Clock PLL Lock. Bit 4 = Demux Lock. Bit 3 = 2047 Pattern Lock Detect. Bit 2 = Buffer Full. Bit 1 = reserved. Bit 0 = Configuration. A–38 SNM-1002 LinkSync Modem Remote Control Operation Revision 2 MN/SNM1002.OM Character 'm': Interface receive side faults character 4. Bit 6 = 1 always. Bit 5 = RX Audio Channel 1 Clip. Bit 4 = RX Audio Channel 2 Clip. Bit 3 = reserved. Bit 2 = reserved. Bit 1 = reserved. Bit 0 = reserved. Character 'n': Common equipment fault status character 1. Bit 6 = 1 always. Bit 5 = Monitor & Control Module. Bit 4 = Interface Module. Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of common equipment stored faults. Character 'o': Common equipment fault status character 2. Bit 6 = 1 always. Bit 5 = Battery/Clock. Bit 4 = +5V power supply. Bit 3 = reserved. Bit 2 = +12V power supply. Bit 1 = -12V power supply. Bit 0 = reserved. Character 'p': Interface backward alarm status character 1. Bit 6 = 1 always. Bit 5 = TX Backward Alarm 1. Bit 4 = TX Backward Alarm 2. Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of backward alarm stored faults. Character 'q': Interface backward alarm status character 2. Bit 6 = 1 always. Bit 5 = TX Backward Alarm 3. Bit 4 = TX Backward Alarm 4. Bit 3 = RX Backward Alarm 1. Bit 2 = RX Backward Alarm 2. Bit 1 = RX Backward Alarm 3. Bit 0 = RX Backward Alarm 4. Character 'r': Interface Reed-Solomon Unavailable Seconds Bit 6 = 1 always. Bit 5 = not used. Bit 4 = not used. Bit 3 through Bit 0 = Binary representation (0 to 10) of the number of Reed-Solomon Unavailable Seconds stored faults. A–39 SNM-1002 LinkSync Modem Remote Control Operation Change Status Command: Response: Revision 2 MN/SNM1002.OM Where: <add/CS_'cr' >add/CS_x'cr''lf'] The 'x' character is defined as follows: '@' = no change since last BCS_ and BCSF_ polls. 'A' = BCS_ response has changed since last BCS_ poll. 'B' = BCSF_ response has changed since last BCSF_ poll. 'C' = Both responses have changed since last BCS_ and BCSF_ polls. This command indicates that a change has or has not occurred on either the BCS_ or the BCSF_ response since the last BCS_ or BCSF_ poll. Equipment Type Command: Response: <add/ET_'cr' >add/ET_tttttttt_xxx.yyy.zzz'cr''lf'] Where: tttttttt = Equipment type. xxx.yyy.zzz = Software version. Monitor & Control Firmware Information Command: Response: <add/MCFI_'cr' >add/MCFI_'cr' VER_xxx.yyy.zzz'cr' FW/nnnnnn-ddr'cr' mm/dd/yy'cr''lf'] Where: xxx.yyy.zzz = Software version number (0.0.0 to 999.999.999). nnnnnn = Firmware number (0 to 999999). dd = Firmware dash number (0 to 99). r = Firmware revision (-, or A to Z). DATA ROM Firmware Information Command: Response: Where: nnnnnn = Firmware number (0 to 999999). dd = Firmware dash number (0 to 99). r = Firmware revision (-, or A to Z). <add/DFI_'cr' >add/DFI_'cr' FW/nnnnnn-ddr'cr' mm/dd/yy'cr''lf'] Note: If Dash number is not used, '-dd' will be reported. Boot M&C Firmware Information Command: Response: Where: <add/BFI_'cr' >add/BFI_'cr' VER_xxx.yyy.zzz'cr' FW/nnnnnn-ddr'cr' mm/dd/yy'cr''lf'] xxx.yyy.zzz = Software version number (0.0.0 to 999.999.999). nnnnnn = Firmware number (0 to 999999). dd = Firmware dash number (0 to 99). r = Firmware revision (-, or A to Z). A–40 SNM-1002 LinkSync Modem Remote Control Operation Modem Options/ Misc. Information Command: Response: Revision 2 MN/SNM1002.OM <add/MOI_'cr' >add/MOI_'cr' s,HGH_PWR'cr' s,HGH_STAB'cr' s,ASLT'cr' s,VIT'cr' s,SEQ'cr' s,SR'cr' s,LRV'cr' s,FRV'cr' s,CARD_1_PCB'cr' s,CARD_2_PCB'cr' s,CARD_3_PCB'cr' s,8PSK_2/3'cr' (0 or +) High Power (0 or +) High Stability (- or +) Asymmetrical Loop Timing (- or +) Viterbi Encoder/Decoder (- or +) Sequential Encoder/Decoder (- or +) Single Code/Data Rate (- or +) Low Rate Variable (- or +) Full Rate Variable (x or +) Card #1 Installed (x or +) Card #2 Installed (x or +) Card #3 Installed (- or +) 8PSK 2/3 Code Rate (0 or +) TX Only Operation (0 or +) RX Only Operation s,TX_ONLY'cr' s,RX_ONLY'cr''lf'] Notes: 1. 2. 3. 4. Serial Number Built In Self Test Command: Response: Command: Response: s = 0 (Not Installed, Not Upgradable). - (Not Installed, FAST Upgradable). + (Installed). X (Not Installed, Field Upgradable). <add/SNUM_'cr' >add/SNUM_'cr' MODEM_xxxxxxxxx'cr' CARD_1_xxxxxxxxx'cr' (Note 1) CARD_2_xxxxxxxxx'cr' (Note 2) CARD_3_xxxxxxxxx'cr''lf'] (Note 3) Where: xxxxxxxxx = Serial number 000000000 to 999999999. <add/BIST_xxxx'cr' for (OFF or AUTO): >add/BIST_xxxx'cr''lf'] Where: xxxx = OFF (self test disabled), RUN (run self test now), AUTO (run self test on power up/software restart). Notes: 1. 2. 3. Data is only returned if Card #1 is installed. Data is only returned if Card #2 is installed. Data is only returned if Card #3 is installed. for (RUN): >add/BIST_xxxx'cr' ST_xxx'cr''lf'] Self Test (OK/FLT) Status: Response: <add/BIST_xxxx'cr' >add/BIST_xxxx'cr''lf'] Note: Allow 35 Seconds for response to RUN the Self Test. A–41 SNM-1002 LinkSync Modem Remote Control Operation State Of Product Command: Response: <add/SOP_'cr' >add/SOP_'cr' add'cr' abc'cr' rrrrr bps'cr' <var-string1>'cr' <var-string2>'cr''lf'] Revision 2 MN/SNM1002.OM Product address Data format Baud rate Comm type Where: abc = Explained below. a = Number of data bits ( 7 ) b = Parity type (O, E, N) c = Number of stop bits (2) rrrrr = baud rate ("150", "300", "600", "1200", "2400", "4800", "9600", "14.4K", "19.2K"). <var-string1> = Variable length strings explaining communication hardware type "RS-485, 2 wire", "RS485, 4 wire", "RS-232". <var_string2> = Variable length strings explaining the intention of the product. "Under normal system operation", "REFLASH of BULK firmware required", "REFLASH of M&C firmware required". A–42 METRIC CONVERSIONS Units of Length Unit Centimeter Inch Foot Yard Mile Meter Kilometer Millimeter 1 centimeter — 0.3937 0.03281 0.01094 6.214 x 10-6 0.01 — — 1 inch 2.540 — 0.08333 0.2778 1.578 x 10-5 0.254 — 25.4 1 foot 30.480 12.0 — 0.3333 1.893 x 10-4 0.3048 — — 1 yard 91.44 36.0 3.0 — 5.679 x 10-4 0.9144 — — 1 meter 100.0 39.37 3.281 1.094 6.214 x 10-4 — — — 1 mile 1.609 x 105 6.336 x 104 5.280 x 103 1.760 x 103 — 1.609 x 103 1.609 — 1 mm — 0.03937 — — — — — — 1 kilometer — — — — 0.621 — — — Temperature Conversions ° Fahrenheit Unit ° Centigrade Formulas 0 — C = (F - 32) * 0.555 (water freezes) 32° Fahrenheit 100 — F = (C * 1.8) + 32 (water boils) 212° Fahrenheit 273.1 — (absolute 0) -459.6° Fahrenheit Units of Weight Gram Ounce Avoirdupois Ounce Troy Pound Avoir. Pound Troy Kilogram — 0.03527 0.03215 0.002205 0.002679 0.001 1 oz. avoir. 28.35 — 0.9115 0.0625 0.07595 0.02835 1 oz. troy 31.10 1.097 — 0.06857 0.08333 0.03110 1 lb. avoir. 453.6 16.0 14.58 — 1.215 0.4536 1 lb. Troy 373.2 13.17 12.0 0.8229 — 0.3732 1 kilogram 1.0 x 103 35.27 32.15 2.205 2.679 — Unit 1 gram 2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 • 333 • 2200 PHONE 480 • 333 • 2161 FAX ">
Download
Advertisement
Key features
High performance, digital modem
Provides LinkSync™ functionality for MIDAS
Built-in scramblers/descramblers
Differential encoder/decoder
TX and RX frequency synthesizers
Multi-rate FEC convolutional Viterbi Decoder
Extensive online monitoring
Frequently asked questions
The SNM-1002 operates within the range of 50 to 180 MHz, in 1 Hz steps.
The SNM-1002 supports QPSK and BPSK modulation types.
The SNM-1002 supports EIA-422/449 on a 37-pin D connector, and CCIT INTELSAT V.35.
The SNM-1002 supports data rates from 2.4 kbps to 4.375 Mbps.
The SNM-1002 uses Viterbi coding with a rate of 1/2, 3/4, or 7/8.
The SNM-1002 has an adjustable output power from -5 to –30 dBm, in 0.1 dB steps.
The SNM-1002 accepts input power from -30 to –55 dBm for the desired carrier.
The SNM-1002 provides diagnostic features such as BER monitoring, buffer fill status monitoring, fault monitoring, IF loopback, input IF power monitoring, remote control via serial port, RF loopback.