CAT.ES30-5 D Refrigerated Air dryer Series IDU/IDF In compliance with the Montreal Protocol Regulations, SMC uses refrigerants R134a and R407C in its refrigerated air dryers to prevent any damage to the earth's ozone layer. Large models IDF190D and 240D newly introduced R134a used in small models (IDU3D to 8D, IDF1D to 8D) R407C used in large models (IDF120D, 150D, 190D, 240D) Montreal Protocol Regulation Compliant Refrigerated Air Dryer Series IDU/IDF Uses refrigerants ( R134a, R407C ) that are harmless to the ozone layer IDU3D, 4D, 6D, 8D/IDF1D, 2D, 3D, 4D, 6D, 8D …… R134a IDF120D, 150D, 190D, 240D …… R407C In compliance with the Montreal Protocol Regulations, SMC uses refrigerants R134a and R407C to prevent any damage to the earth's ozone layer. (Medium size series use R22, ODP = 0.055.) Series IDU (built-in after-cooler) Can be operated directly connected to a screw compressor Coaxial copper piping design prevents rust formation. Provides a stable supply of dry air even under high demand conditions with an inlet air temperature of 60°C. IDU3D to 6D: 60°C IDU8D to 37C1: 55°C IDU55C, 75C: 50°C IDU3D, 4D, IDF1D to 4D Rust-free heat exchanger Quiet operation allows indoor use in locations such as dental offices, etc. Series IDF Can accommodate an inlet air temperature of 40°C System efficiency is improved by using a high performance heat exchanger. Series IDU IDF1D, 2D, 3D Reduced noise 45dB(A) Meets specified Montreal Protocol Regulations Small series: R134a Medium series: R22 Large series: R407C Series IDF IDU3D to 15C, IDF3D to 15C Available in single phase 200VAC without transformer Features 1 Series Variations Note) Air flow capacity (l/min(ANR) 50 Hz 60Hz Series Medium Large Water cooled Large Air cooled Standard inlet air temperature type Rated temperature of 35 to 40°C Medium Small Series IDF Medium Air cooled High inlet air temperature type Rated temperature of 50 to 60°C Small Series IDU IDU3D 300 350 2.2 IDU4D 430 500 3.7 IDU6D 640 750 5.5 IDU8D 850 1000 7.5 IDU11D 1300 –– IDU11C 1300 1500 IDU15C 2050 2400 15 IDU22C/22C1 3150 3700 22 IDU37C/37C1 5200 6100 37 11 IDU55C 7650 9000 55 IDU75C 10500 12400 75 IDF1D 100 120 0.75 IDF2D 200 235 1.5 IDF3D 300 350 2.2 500 3.7 Rated inlet Refrigerant air temp. Air connection 60°C R 1/2 55°C R134a R 3/4 55°C R22 R1 R 1 1/2 50°C 35°C Rc 3/8 R134a 9 to 12 40°C 640 750 5.5 R 1/2 IDF8D 850 1000 7.5 R 3/4 IDF11D 1300 –– IDF11C 1300 1500 IDF15C/15C1 2050 2400 15 IDF22C/22C1 3150 3700 22 IDF37C/37C1 5200 6100 37 7650 9000 55 IDF75C 10500 12400 75 IDF120D 20000 23000 120 IDF150D 25000 30000 150 IDF190D 32000 38000 190 IDF240D 43000 50000 240 IDF75C 10500 12400 75 IDF120D 20000 23000 120 IDF150D 25000 30000 150 IDF190D 32000 38000 190 IDF240D 43000 50000 240 IDF370B 54000 65000 370 Max. operating pressure 1.5MPa With terminal block for signal With terminal block for run & alarm signals and remote operations R134a R22 R 3/4 40°C R1 13 to 15 R 1 1/2 R2 2 1/2B flange R407C 40°C 3B flange 16 to 18 4B flange R22 40°C R2 13 to 15 2 1/2B flange R407C R22 For cool compressed air output. With anti-corrosive treatment of copper tube. With evaporation thermometer 40°C 3B flange 35°C 4B flange 6B flange With motor operated auto drain. With circuit breaker. With power cord connection. Water cooled condenser. Transformer Dust proof filter set Bypass piping set This is for power supply other than specified. Available base to integrate transformer. Avoids decrease of air dryer performance even in dirty environment. Easy bypass piping (just connect this set to air dryer). Substantial reduction of installation labor. Accessories 16 to 18 19 to 20 21 to 24 (Options) Technical Data 5 to 8 R2 IDF6D IDF55C 1 to 4 R 3/4 430 11 Page Rc 3/8 R134a IDF4D For medium air pressure Options Screw type air compressor power (kW) Pressure dew point–Condensed water calculation chart, Pressure dew point temperature–Atmospheric pressure dew point temperature conversion cart 25 Note) l/min (ANR) is for reference conditions of 20°C, 1 ATM and 65% relative humidity. Features 2 Model Selection 1 Obtain the correction factor for the temperature from data A or B and the correction factor for the air pressure from data C. Temperature Data A or B = Series IDU: Data A IDF1D to 240D: Data B-1 IDF 370B: Data B-2 Air pressure Data C = Series IDU and Series IDF: Data C 2 Calculate corrected air flow by using A or B and C. Corrected air flow = (Air flow) ÷ (Data A x Data C) Corrected air flow = (Air flow) ÷ (Data B x Data C) 3 Select a model having an air flow capacity that is higher than the corrected air flow. IDU selection example IDF selection example The procedure for selecting the optimum model under the following conditions is shown below. The procedure for selecting the optimum model under the following conditions is shown below. Condition Condition Inlet air temperature 55°C Inlet air temperature 40°C Outlet air pressure dew point 10°C Outlet air pressure dew point 10°C Ambient temperature 35°C Ambient temperature 35°C Inlet air pressure 0.7MPa Inlet air pressure 0.5MPa Air flow 350 l/min (ANR) Air flow 1200 l/min (ANR) Power supply frequency 50Hz Power supply frequency 60Hz 1 A = 0.85 based on conditions 2 C = 1.00 based on condition 2 C = 0.90 based on condition Based on condition 3 Based on condition 3 , and , A and B Corrected air flow = 350 ÷ (0.85 x 1.00) = 412 l/min (ANR) 4 Based on condition ; 1 B-1 = 0.95 based on conditions , and , B-1 and C Corrected air flow = 1200 ÷ (0.95 x 0.90) = 1400 l/min (ANR) 4 Based on condition ; IDU4D is selected as the model to process an air flow larger than 412 l/min IDF11C is selected as the model to process an air flow larger than (ANR) with a 50Hz power supply, according to data D-1. 1400 l/min (ANR) with a 60Hz power supply, according to data D-2. Note) l/min (ANR) is for reference conditions of 20°C, 1 ATM and 65% relative humidity. Features 3 Model Selection Data A Correction factor for temperature/Series IDU Inlet air temp. IDU3D to 6D (°C) Ambient temperature (°C) 50 55 60 70 80 IDU8D to 15C 45 50 55 65 75 IDU22C1, 37C1 45 50 55 65 70 IDU55C, 75C 40 45 50 55 60 Outlet air pressure dew point (°C) 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 25 0.60 1.35 1.35 0.60 1.35 1.35 0.60 1.35 1.35 0.60 1.35 1.35 0.60 1.35 1.35 30 0.60 1.25 1.35 0.55 1.20 1.35 0.50 1.10 1.35 0.50 1.05 1.35 0.50 1.05 1.35 32 0.60 1.25 1.35 0.55 1.15 1.35 0.50 1.00 1.30 0.45 0.95 1.25 0.45 0.95 1.25 35 0.50 0.95 1.25 0.45 0.85 1.15 0.35 0.75 1.05 0.30 0.70 1.00 0.30 0.70 1.00 40 0.25 0.70 1.00 0.20 0.65 0.90 0.15 0.55 0.80 0.10 0.50 0.80 0.10 0.50 0.80 Data B-1 Correction factor for temperature/Series IDF (IDF1D to 240D) Inlet air IDF 1D temp. (°C) IDF 2D to 240D Ambient temp. (°C) Outlet air press. dew point (°C) 25 30 35 40 50 30 35 40 45 50 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 25 0.60 1.35 1.35 0.60 1.35 1.35 0.50 1.10 1.35 0.35 0.90 1.20 0.20 0.65 1.00 30 0.60 1.35 1.35 0.60 1.30 1.35 0.50 1.05 1.35 0.35 0.80 1.15 0.20 0.60 0.95 32 0.60 1.35 1.35 0.60 1.25 1.35 0.50 1.00 1.30 0.35 0.80 1.10 0.20 0.60 0.90 35 0.55 1.35 1.35 0.55 1.20 1.35 0.50 0.95 1.25 0.35 0.75 1.05 0.15 0.60 0.90 40 0.40 1.35 1.35 0.40 1.15 1.50 0.35 0.90 1.15 0.25 0.70 1.00 0.15 0.55 0.80 Data B-2 Correction factor for temperature/Series IDF (IDF370B) Inlet air temp. (°C) Outlet air pressure dew point (°C) Ambient temp. (°C) 35 30 40 45 50 5 10 15 5 10 15 5 10 15 5 10 15 5 10 15 25 0.90 1.50 2.10 0.72 1.20 1.68 0.60 1.00 1.39 0.50 0.84 1.18 0.43 0.72 1.01 30 0.80 1.34 1.87 0.64 1.07 1.50 0.53 0.89 1.24 0.45 0.75 1.05 0.39 0.64 0.90 32 0.75 1.25 1.75 0.60 1.00 1.40 0.50 0.83 1.16 0.42 0.70 0.98 0.36 0.60 0.84 35 0.68 1.13 1.58 0.54 0.90 1.26 0.45 0.75 1.05 0.38 0.63 0.88 0.32 0.54 0.76 43 0.45 0.75 1.05 0.36 0.60 0.84 0.30 0.50 0.69 0.25 0.42 0.59 0.21 0.36 0.51 Data C Correction factor for air pressure/Series IDU and IDF Inlet air pressure (MPa) 0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Correction factor 0.65 0.68 0.77 0.84 0.90 0.95 1.00 1.03 1.06 1.08 Data D-1 Air flow capacity/Series IDU Model IDU3D IDU4D IDU6D IDU8D IDU11C IDU15C IDU22C1 IDU37C1 IDU55C IDU75C Air flow capacity 50Hz (l/min (ANR)) 60Hz 300 430 640 850 1300 2050 3150 5200 7650 10500 350 500 750 1000 1500 2400 3700 6100 9000 12400 Data D-2 Air flow capacity/Series IDF Model Air flow capacity 50Hz (l/min (ANR)) 60Hz IDF1D IDF2D IDF3D IDF4D IDF6D IDF8D IDF11C IDF15C IDF22C1 IDF37C1 IDF55C IDF75C IDF120D IDF150D IDF190D IDF240D IDF370B 100 200 300 430 640 850 1300 2050 3150 5200 7650 10500 20000 25000 32000 43000 54000 120 235 350 500 750 1000 1500 2400 3700 6100 9000 12400 23000 30000 38000 50000 65000 Features 4 Refrigerant R134a Series IDU Small 3D, 4D, 6D, 8D How to Order IDU Model Voltage 3D 4D 6D 8D 1 2 4 6 Options (No options for standard specification models) Voltage Model Air compressor Refrigerant 3D 4D 6D 8D 2.2kW 3.7kW 5.5kW 7.5kW R134a 100VAC (50Hz) 100 to 110VAC (60Hz) 1 200VAC (50Hz) Single 200 to 220VAC (60Hz) phase 240VAC (50Hz) 2 220 to 240VAC (50Hz) 4 220VAC (50Hz) 6 C E H L M R S T Model and voltage combinations Voltage Model 3D 4D 6D 8D 4 6 220 to 240VAC 240VAC (50Hz) 220VAC (50Hz) 100 to 110VAC (60Hz) 200 to 220VAC (60Hz) (50Hz) 1 100VAC (50Hz) 2 200VAC (50Hz) Note 1) Single phase 200 to 240VAC is "S" specification standard. Note 2) Combinations of H and M, R and S, S and T, L and M are not available. Note 3) Option "T" is not available for IDU6D, 8D-4 and -6. Option C Optional specification With Model 3D 4D 6D 8D anticorrosive treatment E H L R For With With With motor With evaporation medium air heavy duty operated circuit thermometer pressure auto drain auto drain breaker S T With terminal With block for run & power cord alarm signal and connection remote operation Note 3) Standard ∗ Refer to pages 19 and 20 for further information on options. 1 M Note 3) IDU Series Refrigerated Air Dryer Small Standard Specifications/Models Electrical Specifications Operating Ranges Rated Conditions Specification Air flow rate Note 2) l/min (ANR) Operating pressure (MPa) Inlet air temperature (°C) Ambient temperature (°C) Pressure dew point (°C) Working fluid Inlet air temperature (°C) Inlet air pressure (MPa) Ambient temperature (°C) JIS Symbol IDU3D IDU4D IDU6D IDU8D 50Hz 60Hz 300 350 430 500 640 750 850 1000 0.7 60 Auto drain 55 32 10 Compressed air 5 to 80 5 to 75 0.15 to 1.0 2 to 40 (Relative humidity of 85% or less) Single phase, 100/100 to 110VAC (50/60Hz) Single phase, 200/200 to 220VAC (50/60Hz) Single phase, 220, 240/200 to 240VAC (50Hz) Power source 225 250 305 340 275 350 380 415 205 220 300 325 240 280 350 375 – – – 332 182 265 280 – 189 275 295 – 10 (for 100VAC), 5 (for 200VAC) Air cooled R134a 50Hz 60Hz 50Hz 200 VAC 60Hz 220 to 50Hz 240VAC 220VAC 50Hz 240VAC 50Hz 100 VAC Power consumption (W) Circuit breaker (A) Note 3) Condenser Refrigerant Air connection Drain connection Auto drain Refrigerated air dryer Air cooling after cooler Model Rc 1/2 Rc 3/4 Rc 3/8 Rc 1/4 Drain tube ø10 attached INA-20-41-04 Note 5) AD43 23 31 43 47 24 31 46 53 Munsell 10Y8/0.5 (White) 100 to 200VAC 220 to 240VAC Weight (kg) Coating color Applicable compressor (screw type) kW 2.2 3.7 5.5 7.5 Note 1) Select an air dryer according to the selection method and not the rated conditions. Note 2) The data for l/min (ANR) refers to the conditions of 20°C, 1atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of ≤ 30mA. Note 4) IDU3D to 8D-4/6 are only for frequency of 50Hz. Note 5) Spare part for auto drain INA-20-41-04 is AD44-x445. Operation Principles IDU3D Drain separator Compressed air inlet Compressed air outlet Reheater Aftercooler Drain outlet Fan motor Cooler Capacity control valve Humid hot air entering the air dryer is cooled in the aftercooler (air-cooling style) and then further cooled by the cooler. At this time, the condensed moisture is separated from the air by the drain separator and automatically discharged. (IDU3D uses hot refrigerant vapor for reheating.) The dried clean air is heated by the hot air that has entered the dryer. It is then discharged from air dryer outlet. Pressure switch Capillary tube Fan motor Condenser Compressor IDU4D Compressed air outlet Reheater Compressed air inlet IDU6D, 8D Compressed air outlet Drain separator Compressed air inlet Aftercooler Fan motor Drain outlet Aftercooler Evaporation thermometer Cooler Fan motor Capacity control valve Cooler reheater Auto drain Pressure switch Capillary tube Capacity control valve Condenser Fan motor Compressor Drain outlet Valve Condenser Pressure switch Fan motor Capillary tube Compressor 2 Series IDU Small IDU3D, 4D Illuminated switch E B D Compressed air outlet Rc 3/8 A Ventilation direction Compressed air inlet Inspection grill G Rc 3/8 C Ventilation air inlet F Ventilation direction [100VAC specification] Power cord (900) J [200 to 240VAC specification] Terminal block L 63 H 20 Drain tube K 4-ø13 [200 to 240VAC specification] Power cord outlet Model IDU3D IDU4D Port size Rc 3/8 A B C D E F G H 246 496 509 87 125 344 23 175 151 242 591 606 31 170 469 13 171 179 J K L 44 67 206 356 44 67 202 446 : Power source 200 to 240VAC 3 Refrigerated Air Dryer Series IDU Small IDU6D, 8D Compressed air inlet Compressed air outlet (315) 600 (85) 220 (60) (141) (445) Illuminated switch Evaporation thermometer (68) [200 to 240 VAC specification] Power cord outlet A (159) D [200 to 240VAC specification] Terminal block (B) Ventilation air inlet Ventilation air outlet 250 C 278 Drain port Rc 1/4 4-ø13 450 65 [100VAC specification] Power cord ∗ Auto drain is packed together with air dryer. (Some assembly is required.) Model IDU6D IDU8D Port size R 1/2 A B 710 760 R 3/4 810 860 C D 560 551 240 75 : Power source 220 to 240VAC 4 Refrigerant R22, R134a Series IDU Medium 11D, 11C, 15C, 15C1, 22C, 22C1, 37C, 37C1, 55C, 75C How to Order 11D 11C 15C 22C 22C1 37C 37C1 55C 75C 1 2 3 4 6 Voltage Single phase 100VAC (50Hz) 100 to 110VAC (60Hz) 1 Single phase 200VAC (50Hz) 200 to 220VAC (60Hz) 2 Three phase 200VAC (50Hz) 200 to 220VAC (60Hz) 3 Single phase 240VAC (50Hz) 220 to 240VAC (50Hz) 4 Single phase 220VAC (50Hz) 6 Air Refrigerant compressor Model 11D 11C 15C 22C/22C1 37C/37C1 55C 75C 11kW 15kW 22kW 37kW 55kW 75kW Options (No options for standard specification models) R134a R22 Option C Optional With specification anticorrosive Model treatment 11C/11D 15C 22C1/22C 37C1/37C 55C 75C C E H L M R S T Note 1) Options for "-4" and "-6" are not currently available. Please contact our subsidiaries if necessary. Note 2) A combination of two options is standard. A combination of three or more optional items is handled as a special order product. Note 3) 200 to 240VAC is "S" specification standard. Note 4) Combinations of M and H, H and M, R and S, S and T, L and M are not available. Note 5) Option "T" is not available for IDU55C and 75C-4/6. E H With For evaporation high air thermometer pressure L Model and voltage combinations Model 11D 11C 15C 22C 22C1 37C 37C1 55C 75C 5 1 R With With motor With heavy duty operated circuit auto drain auto drain breaker ∗ Refer to pages 19 and 20 for further information on options. Voltage M 2 6 3 4 Single phase Single phase Three phase 100VAC (50Hz) 200VAC (50Hz) 200VAC (50Hz) 220 to 240VAC 240VAC (50Hz) 220VAC (50Hz) (50Hz) 100 to 110VAC (60Hz) 200 to 220VAC (60Hz) 200 to 220VAC (60Hz) S T With terminal With block for run power cord & alarm connection signal Standard Voltage Standard IDU Model Note 5) Note 5) Refrigerated Air Dryer Series IDU Medium Standard Specifications/Models Operating Ranges Rated Conditions Model IDU11D IDU11C IDU15C IDU22C IDU22C1 IDU37C IDU37C1 IDU55C IDU75C Specification 50Hz 1300 1300 2050 3150 5200 7650 10500 Air flow rate Note 2) l/min (ANR) 60Hz — 1500 2400 — 3700 — 6100 9000 12400 Operating pressure (MPa) 0.7 Inlet air temperature (°C) 55 50 Ambient temperature (°C) 32 Pressure dew point (°C) 10 Working fluid Compressed air Inlet air temperature (°C) 5 to 75 5 to 70 5 to 60 Inlet air pressure (MPa) 0.15 to 1.0 Ambient temperature (°C) 2 to 40 (Relative humidity of 85% or less) Electrical Specifications Single phase, 100/100 to 110VAC (50/60Hz) JIS Symbol Refrigerated air dryer Air cooling aftercooler Auto drain Three phase, 200/200 to 220VAC (50/60Hz) 220, 240VAC (50Hz) Single phase, 220, 240VAC (50Hz) 220 to 240VAC (50Hz) Power source 50Hz 60Hz 50Hz 200 VAC 60Hz 220 to 50Hz 240VAC 220VAC 50Hz 240VAC 50Hz 360 583 — — — — — 385 700 — Power 348 597 — 750 — 870 — consumption (W) 384 690 — 880 — 1040 — — — — — — — 377 — 600 790 — 870 — — — 620 815 — 900 — — Circuit breaker (A) Note 3) 10 (for 100VAC), 5 (for 200VAC) 10 Condenser Air cooled Refrigerant R134a R22 Air connection Rc 3/4 Rc 1 Rc 1 1/2 Drain connection Rc 1/4 Auto drain INA-20-41-04 Note 5) 59 100 to 200VAC — 66 — 83 — 114 Weight (kg) — 220 to 240VAC 62 70 85 — 115 — Coating color Munsell 10Y8/0.5 (White) Applicable compressor (screw type) kW 11 15 22 37 100 VAC — — 1520 1910 — 1650 1700 15 2290 2770 — 2340 2390 Rc 2 160 170 185 194 55 75 Note 1) Select an air dryer according to the selection method and not the rated conditions. Note 2) The data for l/min (ANR) refers to the conditions of 20°C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of ≤ 30 mA. Note 4) IDU11D to 75C-4/6 are only for frequency of 50Hz. Note 5) Spare part for auto drain INA-20-41-04 is AD44-x445. Operation Principles Compressed air inlet IDU11D, 11C, 15C Compressed air outlet Aftercooler Fan motor Evaporation thermometer Outlet air pressure gauge Humid hot air entering the air dryer is cooled in the after-cooler. It then enters the reheater to creat an initial condensation with cooled and dehumidified air. The hot air is cooled further and dehumidified inside the cooler as heat is transferred to the refrigerant. The water vapor condensed by the cooling process is cooled and discharged automatically through the auto drain. Cool air is then heated again inside the reheater (heat is transferred from incoming hot air), before leaving the air dryer. Cooler reheater Auto drain Drain outlet Capacity control valve Accumulator Compressor IDU22C to 75C Compressed air inlet Compressed air outlet Valve Condenser Pressure switch Fan motor Capillary tube Aftercooler Outlet air pressure gauge Fan motor Evaporation thermometer Cooler reheater Auto drain Capillary tube Capacity control valve Accumulator Compressor Drain outlet Valve Condenser Pressure switch Fan motor 6 Series IDU Medium IDU11D, 11C, 15C Compressed air inlet Compressed air outlet (F) (68) A 620 Run light (91) (D) (445) Stop switch Operation switch Ventilation direction Outlet air pressure gauge Ventilation direction (Aftercooler) [200 to 240VAC specification] Terminal block Ventilation air outlet B (C) Ventilation air inlet Evaporation thermometer Valve [200 to 240VAC specification] Power cord outlet Ventilation direction (77) Ventilation direction (E) (Condenser) G K J Drain port Rc 1/4 H 470 4-ø13 [100VAC specification] Power cord ∗ Auto drain is packed together with air dryer. (Some assembly is required.) Model Port size A B C D E F G H IDU11C/11D R 3/4 260 910 959 152 157 363 289 317 R1 280 960 1009 175 207 383 309 337 IDU15C : Power source 220 to 240VAC 7 J K 571 580 30 70 65 Series Refrigerated Air Dryer IDU22C, Compressed air inlet IDU Medium 22C1, 37C, 37C1, 55C, 75C Compressed air outlet (K) B (H) A (G) (F) (E) Run light Operation switch (Aftercooler) (Aftercooler) Stop switch Outlet air pressure gauge Ventilation air inlet C (D) Ventilation air outlet Evaporation thermometer Ventilation direction Power cord outlet (I) Ventilation direction Terminal block (Condenser) (J) (Condenser) L M G P Drain port Rc 1/4 N 4-ø13 65 ∗ Auto drain is packed together with air dryer. (Some assembly is required.) Model Port size A B C D E F G H I J K L M N P Q IDU22C1/22C R1 300 750 1155 1235 71 70 445 63 642 219 398 328 356 600 700 700 50 90 IDU37C1/37C R 1 1/2 360 830 1260 1350 112 136 550 68 722 269 463 388 416 680 780 776 50 90 IDU55C R2 405 850 1340 1440 87 155 530 68 722 267 508 433 461 700 800 800 50 95 IDU75C R2 425 850 1475 1575 87 220 530 68 722 317 528 453 481 700 800 800 50 95 : Power source 220 to 240VAC 8 Refrigerant R134a Series IDF Small 1D, 2D, 3D, 4D, 6D, 8D How to Order IDF Model Voltage 1D 2D 3D 4D 6D 8D 1 2 4 6 Options (No options for standard specification models) Voltage 100VAC (50Hz) 100 to 110VAC (60Hz) 1 200VAC (50Hz) Single 200 to 220VAC (60Hz) phase 240VAC (50Hz) 220 to 240VAC (50Hz) 2 220VAC (50Hz) Model 1D 2D 3D 4D 6D 8D A C E H L M R S T 4 Note 1) A combination of three or more optional items is handled as a special order product. Note 2) Single phase 220 to 240VAC is "S" specification standard. Note 3) Combinations of H and M, R and S, S and T, A and H, L and M are not available. Note 4) Option "T" is not available for IDF6D, 8D-4 and -6. 6 Air Refrigerant compressor 0.75kW 1.5kW 2.2kW 3.7kW 5.5kW 7.5kW Option A Optional specification With cool compressed air output Model R134a C E H L 1D 2D 3D 4D 6D Standard 8D ∗ Refer to pages 19 and 20 for further information on options. Model and voltage combinations Voltage Model 1D 2D 3D 4D 6D 8D 9 M With With With For With antievaporation medium air heavy duty motor operated corrosive auto drain auto drain treatment thermometer pressure 1 4 2 6 100VAC (50Hz) 200VAC (50Hz) 220 to 240VAC 240VAC (50Hz) 220VAC (50Hz) 100 to 110VAC (60Hz) 200 to 220VAC (60Hz) (50Hz) R With circuit breaker S T With terminal With block for run & power cord alarm signal and connection remote operation Note 4) Note 4) Refrigerated Air Dryer Series IDF Small Standard Specifications/Models Model Electrical Specifications Operating Ranges Rated Conditions Specification JIS Symbol Refrigerated air dryer Auto drain Air flow rate Note 2) l/min (ANR) Operating pressure (MPa) Inlet air temperature (°C) Ambient temperature (°C) Pressure dew point (°C) Working fluid Inlet air temperature (°C) Inlet air pressure (MPa) Ambient temperature (°C) IDF1D 100 120 50Hz 60Hz 35 Single phase, 100/100 to 110VAC (50/60Hz) Single phase, 100/100 to 110VAC Single phase, 200/200 to 220VAC (50/60Hz) Single phase, 220, 240/220 to 240VAC (50Hz) (50/60Hz) Power source 50Hz 60Hz 200 50Hz VAC 60Hz 220 to 50Hz 240VAC 220VAC 50Hz 240VAC 50Hz 100 VAC Power consumption (W) IDD3D IDF4D IDF6D IDF8D 430 300 640 850 500 350 750 1000 0.7 40 32 10 Compressed air 5 to 50 0.15 to 1.0 2 to 40 (Relative humidity of 85% or less) IDF2D 200 235 Circuit breaker (A) Note 3) Condenser Refrigerant Air connection Drain connection Auto drain 100 to 200VAC Weight (kg) 220 to 240VAC Coating color Applicable compressor (screw type) kW 184 213 — — — — — 187 207 283 210 283 210 250 330 260 330 — 202 280 195 280 — 245 328 240 328 — — 292 — 259 — 247 — 172 — — 257 — 179 — 10 (for 100VAC), 5 (for 200VAC) Air cooled R134a Rc 1/2 Rc 3/4 Rc 3/8 Drain tube ø10 attached Rc 1/4 INA-20-41-04 Note 5) AD53 AD43 15 16 26 32 18 32 — 26 38 19 35 Munsell 10Y8/0.5 (White) 0.75 1.5 3.7 7.5 2.2 5.5 Note 1) Select an air dryer according to the selection method and not the rated conditions. Note 2) The data for l/min (ANR) refers to the conditions of 20°C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of ≤30 mA. Note 4) IDF3D to 8D-4/6 are only for frequency of 50Hz. Note 5) Spare part for auto drain INA-20-41-04 is AD44- x445. Operation Principles IDF2D, 3D IDF1D Drain separator Compressed air inlet Cooler Reheater IDF4D Compressed air inlet Compressed Reheater air outlet Compressed Cooler air outlet Drain outlet Drain separator Cooler Drain outlet Drain outlet Capacity control valve Capacity control valve Pressure switch Capillary Condenser tube Fan motor Reheater Drain separator Compressed air outlet Compressed air inlet Capacity control valve Pressure Condenser switch Fan motor Capillary tube Pressure switch Capillary tube Condenser Compressor Compressor Fan motor Compressor IDF6D, 8D Hot humid air entering the air dryer is cooled by the cooler. At that time, condensed moisture is separated from the air by the drain separator and automatically discharged. The dried clean air is heated by the reheater to about the ambient temperature, and is then discharged from the air dryer outlet. Compressed air inlet Evaporation thermometer Compressed air outlet Cooler reheater Auto drain Drain outlet Capacity control valve Compressor Condenser Pressure switch Fan motor Capillary tube 10 IDF Series Small IDF1D, 2D, 3D Illuminated switch E D B A Ventilation direction Compressed air outlet Rc 3/8 Compressed air inlet Rc 3/8 G Inspection grill Ventilation air inlet F C Ventilation direction [100VAC specification] Power cord J (900) H M N Drain tube L K [200 to 240VAC specification] Power cord outlet [200 to 240VAC specification] Terminal block Port size Model IDF1D Rc 3/8 IDF2D IDF3D A B C D E F G 200 328 395 59 74 247 36 226 328 410 51 125 232 138 226 358 470 67 125 304 33 H 103 J 28 K L M N 34 132 38 198 38 150 24 217 36 154 21 236 : Power source 200 to 240VAC IDF4D Illuminated switch Compressed air outlet Rc 3/8 31 170 481 242 Ventilation direction 13 Compressed air inlet Rc 3/8 Inspection grill Ventilation direction 469 606 Ventilation air inlet [100VAC specification] Power cord 67 (900) 179 [200 to 240VAC specification] Power cord outlet 63 [200 to 240VAC specification] Terminal block 336 20 202 4-ø13 Drain tube : Power source 200 to 240VAC 11 Refrigerated Air Dryer Series IDF Small IDF6D, 8D Compressed air inlet Compressed air outlet (315) 220 600 (141) 410 (456) 120 (72) (60) (68) Illuminated switch Evaporation thermometer Ventilation air inlet Ventilation direction [100VAC specification] Power cord outlet (159) (Condenser) 240 75 Ventilation direction (570) [200 to 240VAC specification] Terminal block 520 Ventilation air outlet 250 560 551 [200 to 240VAC specification] Power cord outlet 278 450 65 4-ø13 Drain port Rc 1/4 : In case of 200VAC. Dimension shown on the right is for 220 to 240VAC. ( ): Dimension within bracket is for air dryer with option A, with cool compressed air output. Air inlet and outlet are reversed for air dryer with option A, with cool compressed air output. ∗ Auto drain is packed together with the air dryer. (Some assembly is required.) Model Port size IDF6D R 1/2 IDF8D R 3/4 12 Refrigerant R22 Series IDF Medium 11D, 11C, 15C, 15C1, 22C, 22C1, 37C, 37C1, 55C, 75C How to Order IDF Model 11D 11C 15C/15C1 22C/22C1 37C/37C1 55C 75C Model Voltage 11D 11C 15C 15C1 22C 22C1 37C 37C1 55C 75C 1 2 3 4 6 Air compressor Refrigerant 11kW 15kW 22kW 37kW 55kW 75kW R134a R22 Options (No options for standard specification models) A C E H L M R S T W Voltage Single phase 100VAC (50Hz) 100 to 110VAC (60Hz) 1 Single phase 200VAC (50Hz) 200 to 220VAC (60Hz) 2 Three phase 200VAC (50Hz) 200 to 220VAC (60Hz) 3 Single phase 240VAC (50Hz) 220 to 240VAC (50Hz) 4 Single phase 220VAC (50Hz) 6 Note 1) A combination of two is standard. A combination of three or more optional items is handled as a special order product. Note 2) 200 to 240VAC is "S" specification standard. Note 3) Combinations of A and H, H and M, R and S, S and T are not available. Note 4) Options "T" and "W" are not available for IDF37C, 55C and 75C-4/6. E H L With With motor For medium With evaporation air pressure heavy duty operated thermometer auto drain auto drain ∗ Refer to pages 19 and 20 for further information on options. Model and voltage combinations Voltage Model 11D 11C 15C 15C1 22C 22C1 37C 37C1 55C 75C 13 1 M 2 3 4 6 Single phase Single phase Three phase 100VAC (50Hz) 200VAC (50Hz) 200VAC (50Hz) 220 to 240VAC 240VAC (50Hz) 220VAC (50Hz) 100 to 110VAC (60Hz) 200 to 220VAC (60Hz) 200 to 220VAC (60Hz) (50Hz) R With circuit breaker S T W With With terminal Water power cord block for run cooled connection & alarm signal condenser Standard 11C/11D 15C/15C1 22C/22C1 37C/37C1 55C 75C C With anticorrosive treatment Standard Option A Optional specification With cool compressed Model air output Note 4) Note 4) Note 4) Note 4) Note 4) Note 4) Refrigerated Air Dryer Series IDF Medium Standard Specifications/Models Model IDF11D IDF11C IDF15C IDF15C1 IDF22C IDF22C1 IDF37C IDR37C1 IDF55C IDF75C 1300 2050 3150 5200 7650 10500 50Hz — 3700 — 6100 9000 12400 60Hz — 1500 2400 — Operating pressure (MPa) 0.7 Inlet air temperature (°C) 40 Ambient temperature (°C) 32 Pressure dew point (°C) 10 Working fluid Compressed air Inlet air temperature (°C) 5 to 50 Inlet air pressure (MPa) 0.15 to 1.0 Ambient temperature (°C) 2 to 40 (Relative humidity of 85% or less) Operating Ranges Rated Conditions Specification Air flow rate Note 2) l/min (ANR) Electrical Specifications Single phase, 100/100 to 110VAC (50/60Hz) JIS Symbol Refrigerated air dryer Auto drain Power source 220, 240VAC (50Hz) 220 to 240VAC (50Hz) Three phase, 200/200 to 220VAC (50/60Hz) Single phase, 220, 240VAC (50Hz) — — — — 50Hz — 320 543 — — — — — 60Hz — 347 662 — Power — 670 — 750 50Hz — 308 561 — 200 VAC 60Hz — 346 652 — consumption (W) — 800 — 880 220 to — — 337 — — — — — 50Hz 240VAC 220VAC 50Hz — — — 548 747 — 830 — 240VAC 50Hz — — — 570 777 — 860 — Circuit breaker (A) Note 3) 10 10 (for 100VAC), 5 (for 200VAC) Condenser Air cooled Refrigerant R134a R22 Air connection Rc 3/4 Rc 1 Rc 1 1/2 Drain connection Rc 1/4 Auto drain INA-20-41-04 Note 5) 100 to 200VAC — 47 50 — — 60 — 72 Weight (kg) 220 to 240VAC 50 — — 53 60 — 72 — Coating color Munsell 10Y8/0.5 (White) Applicable compressor (screw type) kW 11 15 22 37 100 VAC — — — — 1400 2100 1750 2150 — — 1530 2150 1580 2200 15 Rc 2 114 126 125 135 55 75 Note 1) Select an air dryer according to the selection method and not the rated conditions. Note 2) The data for l/min (ANR) refers to the conditions of 20°C, 1 atm. pressure and relative humidity of 65%. Note 3) Install a circuit breaker with sensitivity of ≤30 mA. Note 4) IDU11D to 75C-4/6 are only for frequency of 50Hz. Note 5) Spare part for auto drain INA-20-41-04 is AD44- x445. Operation Principles IDF11D, 11C, 15C, 15C1 Compressed air inlet Evaporation thermometer Compressed air outlet Outlet air pressure gauge Cooler reheater Auto drain Drain outlet Capacity control valve Accumulator Condenser Compressor Pressure switch Fan motor Hot humid air entering the reheater is precooled by dehumidified cool air. (The hot air is cooled further and dehumidified inside the cooler as heat is transferred to the refrigerant. The water condensed by the cooling process is collected and discharged automatically by the auto drain.) Finally, the cool dehumidified air is heated in the reheater by hot inlet air and discharged in a dry state. Capillary tube IDF22C, 22C1, 37C1, 55C, 75C Compressed air inlet Evaporation thermometer Compressed air outlet Outlet air pressure gauge Cooler reheater Auto drain Capacity control valve Capillary tube Accumulator Condenser Compressor Pressure switch Fan motor Drain outlet 14 Series IDF Medium IDF11D, 11C, 15C, 15C1, 22C, 22C1, 37C1, 55C, 75C Compressed air outlet Compressed air inlet (J) (F) (68) A B Run light Stop switch (G) IDF11D, 11C, 15C, 15C1 (E) (H) Operation switch Outlet air pressure gauge Ventilation air outlet Evaporation thermometer (I) [100VAC specification] Power cord IDF11C, 15C K P (Condenser) C Ventilation direction Ventilation direction (D) [200 to 240VAC specification] Terminal block Ventilation air inlet N L [200 to 240VAC specification] Power cord outlet 65 M 4-ø13 Drain Port Rc 1/4 IDF22C, 22C1, 37C1 to 75C (H) Ventilation air outlet 65 M 4-ø13 ∗ Auto drain is packed together with the air dryer. (Some assembly is required.) Model Port size A B C D E F G H I J K L M N P IDF11C/11D R 3/4 260 620 570 630 152 131 (85) 405 (450) 77 157 363 289 317 470 580 580 70 65 IDF15C/15C R1 280 620 620 680 175 131 (85) 405 (450) 77 207 383 309 337 470 580 580 70 65 IDF22C/22C1 R1 295 750 680 760 183 98 405 (530) 642 199 398 323 351 600 700 700 70 30 IDF37C/37C1 R 1 1/2 320 830 730 810 208 98 405 (610) 722 249 423 348 376 680 776 780 70 30 IDF55C R2 405 850 850 930 85 98 405 (610) 722 247 508 433 461 700 800 800 75 30 IDF75C R2 425 850 900 980 85 98 405 (610) 722 297 528 453 481 700 802 800 75 30 : Power source 200VAC. Dimension shown on the right is for 220 to 240VAC. ( ): Dimension within bracket is for air dryer with option A, with cool compressed air output. Air inlet and outlet are reversed for air dryer with option A, with cool compressed air output. 15 Refrigerant R407C, R22 Series IDF Large 120D, 150D, 190D, 240D, 370B How to Order Refrigerant R407C 120D, 150D IDF Model Voltage 120D 150D 190D 240D 3 7 8 9 120kW 150kW 190kW 240kW C M R W 220V 240V 400V 440V Voltage Symbol 200/200 to 220VAC (50/60Hz) 3 Three 380VAC (50Hz) 7 phase 415VAC (50Hz) 8 Built-in transformer 9 Air Model compressor Refrigerant 120D 150D 190D 240D Options (No options for standard specification models) Model R407C 3 7 8 Note 2) Possible to combine 2 options. When requiring 3 options or more, it is made to order. Option Note 1) Select one applicable voltage. 9 Symbol C M R W With anticorrosive treatment With motor operated auto drain With circuit breaker Watercooled condenser 3 7 8 9 120D 150D 190D 240D Refrigerant R22 370B IDF Size Port size Voltage 370B 60 3 Options (No options for standard specification models) X202 X204 X205 Symbol Air Model compressor Refrigerant 370B 370kW R22 Option Model Symbol 370B 60 Port size 6B flange Model Symbol 370B 3 Voltage Three phase 200VAC (50/60Hz) Size X202 With circuit braker X204 X205 With Heavy anti-corrosive duty auto treatment drain 370B Integrated with Transformer (Option) Model IDF 370B Air Model compressor Refrigerant 370B 370kW R22 Primary side at transformer Port size 60 9 Model Symbol 370B 60 Port size 6B flange 220V 240V 380V 400V 415V 440V 16 Series IDF Large Standard Specifications/Models Rated conditions Operating ranges Air flow rate Note 1) (m3/min (ANR)) 50Hz 20 25 32 43 54 60Hz 23 30 38 50 65 0.7 Inlet air pressure (MPa) 32 Outlet air pressure dew point (°C) 10 Inlet air temperature (°C) 2 to 40 (Relative humidity of 85% or less) 2 to 43 50Hz 2.5 4.0 4.9 6.3 8.1 60Hz 3.1 5.0 5.9 7.6 9.5 2.1 3.3 – – – 415AVC 2.2 3.4 – – – 200AVC 30 50 50 60 80 15 20 – – – 380AVC 50Hz 380AVC 1 1/4B union Note 1) Value for inlet water temperature of 32°C and rated load. Note 2) Value calculated for 1RT = 3, 300kcal/h. Operation cycle Operation time Model Three phase 200/220VAC (50/60Hz) Three phase 200/220VAC (50/60Hz) Three phase Three phase 380VAC (50Hz) Three phase 380VAC (50Hz) 200/220VAC Three phase 415VAC (50Hz) Three phase 415VAC (50Hz) (50/60Hz) 200AVC 10RT Pressure style automatic water supply valve Water flow regulator 4 cycles/min. IDF370B 0.15 to 0.1 Ambient temperature (Humidity) (°C) 100 l/min Auto drain 5 to 50 Inlet air pressure (MPa) Circuit breaker (A) Cooling tower capacity Note 2) Compressed air Working fluid Shell and tube system Cooling water flow Note 1) 35 Ambient temperature (°C) Power consumption (kw) Condenser Connection bore on water side 40 Inlet air temperature (°C) Power source Electrical specifications Water cooled condenser specifications (IDF370B) Note 2) Model IDF120D IDF150D IDF190D IDF240D IDF370B Specification 8 sec./min. Power supply 200VAC 50/60Hz. Power consumption 4W JIS Symbol Refrigerated air dryer Auto drain 451AVC Condenser Air cooled Refrigerant R407C Air connection 2 1/2B flange Water cooled R22 4B flange 6B flange 3B flange Drain connection (Rc) Rc 1/2 Auto drain Rc 3/8 ADH4000-04 Weight (kg) 330 350 ADM200-042-8 660 450 1100 Body panel: Munsell 10Y8/0.5 (White) Coating color Base: Black Applicable compressor (kw) 120 150 190 Front panel: Munsell 2.5PB5/8.5 (Blue) Other panels (Except base): Munsell N-8 (White) 370 240 Note 1) The data for l/min (ANR) refers to the conditions of 20°C, 1atm. pressure and relative humidity of 65%. Note 2) This is made to order. Operation Principles IDF370B IDF120D to 240D Air reheater Compressed air inlet Pressure gauge Compressed air inlet Compressed air outlet (humid and high (dry and warm air) temperature air) Air cooler Condenser Accumulator Compressed air outlet Auto drain Drain Evaporation thermometer Capillary tube Low pressure switch Volume control valve Compressor Pressure switch High pressure switch Condenser Automatic water supply valve Air reheater Water cooled condenser Air cooler Fan motor High temperature humid air is cooled in the reheater . Then it is further cooled to a specified temperature using the evaporation heat in the air cooler . The oil mist and moisture occurring due to condensation is exhausted through the auto drain . Cooled and dehumidified air is returned to the air reheater and heat is transferred from the incoming high temperature air. It is then exhausted out of the air dryer as dry air. 17 Volume control valve Temperature expansion valve Drain Motor operated auto drain Refrigerated Air Dryer IDF120D, 150D, Series IDF Large 190D, 240D Ventilation direction K (80) A Port size (JIS 10K) 100 B Compressed air inlet Ventilation air inlet Ventilation direction C F Ventilation direction D Power supply cable entry 200 J E Rc 1/2 Compressed air outlet G 650 Model Port size IDF120D JIS 10K 2B 1/2 Flange I H Anchor bolt hole 4-ø20 A B C D E F G H I J K 650 1200 1300 325 470 600 600 660 330 365 780 IDF190D JIS 10K 3B Flange 750 1510 1320 375 480 600 700 800 355 427 880 IDF240D JIS 10K 4B Flange 770 1550 1640 385 703 730 700 800 355 592 900 IDF150D JIS 10K 3B Flange ∗ Auto drain is packed together with air dryer. (Some assembly is required.) IDF370B Compressed air inlet Compressed air outlet (310) (280) Port size (JIS 10K 6B) (400) 1670 Power supply cable entry (250) 75 Cooling water inlet (Rc 1 1/4) 650 (800) (190) 100 Cooling water outlet (Rc 1 1/4) (90) (390) (210) 1050 Rc 3/8 1810 Anchor bolt hole 4-ø20 18 Series IDU/IDF Option Specification A Option symbol M Cool compressed air output at 10°C The air flow with this option is lower than that of the standard dryer. ∗ On models IDF6D to 15C, the air inlet and outlet are reversed. ∗∗ Except for IDF1D to 4D, piping dimensions of the air inlet and outlet are different from standard. (Refer to pages 12, 15 and 18.) Model Air flow capacity 50Hz (l/min (ANR)) 50/60Hz 60Hz IDF1D 85 100 IDF2D 120 140 IDF3D 180 210 IDF4D 215 250 Model Air flow capacity (l/min (ANR)) 50/60Hz 50Hz 60Hz IDF6D 320 375 IDF8D 425 500 IDF11C 650 750 IDF15C 1025 1200 50Hz 60Hz IDF22C1 1575 1850 IDF37C1 2600 3050 IDF55C 3825 4500 IDF75C 5250 6200 Model Air flow capacity (l/min (ANR)) 50/60Hz Refer to pages 1, 5, 9, 13 and 16 for "How to order" of options. Option symbol With motor operated auto drain This option changes the float style auto drain (INA-20-41-04) used by standard air dryers to a motor operated auto drain (ADM200-04) where by drainage is discharged more precisely. Operating air pressure 0.3MPa Air discharge if no drainage 6 l (ANR) each time 0.5MPa 10 l (ANR each time 0.7MPa 14 l (ANR) each time ∗ Operation cycle: 1 cycle/min. Operation time: 2 sec./min. IDF220B to 370B standard. (131) Motor operated auto drain (68) [Condition IDF1D] Pressure: 0.7MPa, Saturation: 35°C Ambient temperature: 32°C, Outlet air temperature: 10°C [IDF2D to 75C] Pressure: 0.7MPa, Saturation: 40°C, Ambient temperature: 32°C, Outlet air temperature: 10°C Option symbol Anti-corrosive treatment This minimizes the corrosion of the copper and copper alloy parts when the air dryer is used in an atmosphere containing hydrogen sulfide or sulfurous acid gas. This option extends the service life. Special epoxy coating of copper tube and copper alloy parts. The coating is not applied on the heat exchanger or around electrical parts, where operation may be affected by coating. Drain discharge port Rc 3/8 (A) C Model IDU6D IDU8D IDU11C IDU15C IDU22C1 IDU37C1 IDU55C IDU75C A 309 309 307 357 369 419 417 463 ∗ Motor operated auto drain is packed together with main unit. Assembly is required. Model IDF6D IDF8D IDF11C IDF15C IDF22C1 IDF37C1 IDF55C IDF75C IDF120D IDF150D IDF190D IDF240D A 309 309 307 357 349 399 397 447 464 464 526 690 Note ) For IDF370B, option C is assigned as X204. E R Option symbol With evaporation thermometer A thermometer (pressure gauge) indicating the evaporating temperature of the refrigerant is attached to the operation panel, facilitating maintenance and daily checks. IDU6D to 75C, IDF6D to 370B standard. H Option symbol For medium air pressure Option symbol With circuit breaker X202 (IDF220B, 370B) A circuit breaker with bowl is attached to the side of the air dryer. This saves additional electrical wiring at the time of installation. (IDF120D to 370B do not have an electric leakage detection function.) IDU6D to 75C IDF6D to 75C IDF120D to 240D IDF370B No fuse breaker (B) This option provides a heat exchanger, auto drain, air pressure gauge and ball valve, etc., with a medium pressure capability. This is different from the standard specifications. Maximum operating pressure is 1.5MPa. L Power cord outlet ø35 Option symbol With heavy duty auto drain A dryer with heavy duty auto drain (ADH4000-04) is installed instead of the float type auto drain (INA20-41-04), which is used for standard models to discharge drainage. IDF120D, 150D,190D, 240D standard. Ground fault circuit breaker with bowl Note ) For IDF370B, option L is assigned as X205. Model IDU6D IDU8D IDU11C IDU15C IDU22C1 IDU37C1 IDU55C IDU75C 19 A 210 210 208 258 270 320 318 368 Model IDF6D IDF8D IDF11C IDF15C IDF22C1 IDF37C1 IDF55C IDF75C IDF120D IDF150D IDF190D IDF240D A 210 210 208 258 250 300 298 348 365 365 427 592 Model IDU6D, IDF6D IDU8D, IDF8D IDU11C, IDF11C IDU15C, IDF15C IDU22C1, IDF22C1 IDU37C1, IDF37C1 IDU55C, IDF55C IDU75C, IDF75C IDF120D IDF150D IDF190D IDF240D IDF370B B Breaker capacity Sensitivity current 10A (100VAC) 5A (200VAC) 95 10A 15A 69 94 95 156 30A 45A 50A 60A 80A 15 to 30mA Option Specification Option symbol W With power cord connection This option allows connection of the power supply to a terminal board (3P). IDU3D, 4D, IDF1D to 4D 25 Terminal board Water cooled condenser (IDF37C1 to 240D) This option can be used where the ambient temperature is high (Max. 43°C), and does not reduce air flow capacity. It is also possible to use this option in an enclosed environment to prevent increasing of the surrounding temperature. IDF370B standard. 74 W: Water cooled condenser (IDF37C1 to 240D) A 24 20 47 55 37 45 Model IDU3D IDU4D IDF1D IDF2D IDF3D IDF4D 53 B Power cord outlet B 247 298 123 123 173 197 IDU6D to 15C, IDF6D to 15C IDF37C1 IDF55C IDF75C IDF120D IDF150D IDF190D IDF240D Model Condenser type Shell & coil system Cooling water flow l/min Note1) 6 8 20 50 65 80 90 Cooling tower capacity RT Note 2) 2 2 3 5 7.5 7.5 7.5 Water flow regulator Pressure auto feed valve Connection bore on water side (union) 1/2B 1/2B 3/4B 1B 1B 1B 1B Note 1) Value for inlet water temperature of 32°C and rated load. Note 2) Value calculated for 1RT = 3, 300kcal/h. IDF75C B 40 40 49 49 40 40 40 40 Cooling water outlet B 375 140 158 C 75 75 66 D 153 153 144 E 225 225 181 Cooling water inlet Compressed air pressure gauge Drain Rc 3/8 With plug T Model A IDF37C1 425 IDF55C 190 IDF75C 208 E A B A 240 240 30 30 240 240 65 65 D Model IDU6D IDU8D IDU11C IDU15C IDF6D IDF8D IDF11C IDF15C Power cord outlet (ø17) Grommet with waist Back side A Option symbol C S B A Option symbol With terminal block for run & alarm signal and remote operation IDF120D to 240D 180 B Front side Transformer integrated Signal cord outlet (ø17) Grommet with waist Power cord outlet Grommet with waist ø6 to 12 A 240 240 30 30 50 50 50 50 B 38 38 50 50 45 45 45 45 C 70 70 49 49 50 50 50 50 Model IDF6D IDF8D IDF11C IDF15C IDF22C1 IDF37C1 IDF55C IDF75C A 240 240 65 65 30 30 30 30 B 38 38 32 32 45 45 45 45 C 70 70 40 40 50 50 50 50 Transformer box Power cord outlet (ø36) (560) Model IDU6D IDU8D IDU11C IDU15C IDU22C1 IDU37C1 IDU55C IDU75C C A C The power supply transformer can be integrated with an air dryer. It is used when a refrigerated air dryer is using a non-standard voltage specification. The power supply transformer for IDF120D to 240D is installed inside of the air dryer. Therefore, external dimensions are the same as the standard product. B A Signal cord outlet (ø17) Grommet with waist Drain with plug Rc 3/8 165 85 IDU11C to 75C IDF11C to 75C Power cord outlet (ø17) Grommet with waist Cooling water outlet Compressed air pressure gauge Cooling water inlet (1795) IDU6D, 8D IDF6D, 8D 225 With the optional terminal, in addition to connection of the power supply, the air dryer can be started and stopped by remote control and an operation failure signal can be obtained. (If no voltage contact is made, an operation failure signal will register.) IDF120D to 370B standard. (440) 1700 ±3 (2240) IDF370B 4-ø20 (Anchor bolt hole) 20 Accessories (Options) Description Features Transformer separately installed This is for power supply and voltage other than standard. Base integrated with transformer Specifications Applicable dryer Dimensions Max. ambient temperature 40°C (Relative humidity 85% or less) All models Page 22 __ IDU3D to15C This is the base for integrating the transformer and air dryer. Dust proof filter set Bypass piping set IDF4D to 75C Avoids decreasing of air dryer performance even in dusty atmosphere. Max. ambient temperature 40°C Easy bypass piping (connect this set to the air dryer), realizing substantial reduction of man-hours at the site. Max. operating pressure 1.0MPa Max. operating temperature 60°C IDU3D to 75C Page 23 Page 23 IDF1D to 75C IDU3D to 75C Page 24 IDF1D to 75C How to Order Transformer separately installed IDF TR 1500 Base integrated with transformer 5 IDF Applicable dryer IDU3D-1 to11C-1, 500 500VA IDF1D-1 to11C-1 1000 1kVA IDU15C-1, IDF15C-1 IDU22C1-3, 37C1-3, 1500 1.5kVA IDF22C1-3, 37C1-3 IDU55C-3, 75C-3, 4000 4kVA IDF55C-3, 75C-3 7000 7kVA IDF120D 9000 9kVA IDF150D 11000 11kVA IDF190D 13000 13kVA IDF240D 18000 18kVA IDF370B Symbol Volume Symbol Primary voltage 110VAC (50Hz), 1 110 to 120VAC (60Hz) 200, 220, 230, 240VAC (50Hz), 2 200 to 260VAC (60Hz) 380, 400, 415VAC (50Hz), 3 380 to 420VAC (60Hz) 420, 440, 480VAC (50Hz), 4 420 to 520VAC (60Hz) 220VAC (50Hz), 5 220 to 240VAC (60Hz) 380, 400, 415VAC (50Hz), 6 380 to 440VAC (60HZ) 440, 460VAC (50Hz), 7 440 to 500VAC (60Hz) 220, 240, 380, 400, 415, 8 440VAC (50/60Hz) Dust proof filter set IDU FL 22 C IDF Dryer IDU3D IDU4D Symbol 6 8 11 15 Symbol 6 8 11 15 Single turn Compound Applicable dryer IDU3D, IDF4D IDU4D to 15C, IDF6D to 15C IDF22C1 IDF37C1 to 75C Not available for IDF1D to 3D, IDU22C to 75C. 200VAC (50Hz) Three Single 200 to 220VAC phase turn (60Hz) 200VAC (50/60Hz) Three phase Compound BP 22 C Applicable dryer Dryer IDU6D IDU8D IDU11C IDU15C Symbol 22 37 55 75 Dryer IDU22C1 IDU37C1 IDU55C IDU75C FL 22 C Dryer IDF1D IDF2D IDF3D IDF4D Symbol 1 2 3 4 Model 100VAC (50Hz) Single 100 to 110VAC phase (60Hz) IDU Symbol 3 4 IDF Applicable dryer Symbol 1 2 3 4 Secondary voltage Bypass piping set Applicable dryer Symbol 3 4 Size order Supply voltage Volume TB 2 Dryer IDU3D IDU4D Symbol 6 8 11 15 Dryer IDU6D IDU8D IDU11C IDU15C Symbol 22 37 55 75 Dryer IDU22C1 IDU37C1 IDU55C IDU75C Symbol 22 37 55 75 Dryer IDF22C1 IDF37C1 IDF55C IDF75C BP 22 C Applicable dryer Dryer IDF6D IDF8D IDF11C IDF15C Symbol 22 37 55 75 Dryer IDF22C1 IDF37C1 IDF55C IDF75C Symbol 1 2 3 4 Dryer IDF1D IDF2D IDF3D IDF4D Symbol 6 8 11 15 Dryer IDF6D IDF8D IDF11C IDF15C Cannot be mounted on models with option "A" (IDF6D to 75C). 21 Accessories (Options) Transformers IDF-TR -1 A C B OUT PUT Part No. IN PUT Primary Secondary Capacity Model voltage voltage A Dryer IDF1D-1 to 11C-1 500VA Single IDU3D-1 to 11C-1 phase Single IDF15C-1 1kVA turn IDF-TR1000-1 IDU15C-1 IDF-TR500-1 4-F E D Input cord 2m IDF-TR 110VAC 100VAC (50Hz) (50Hz) 110 to 100 to 120VAC 110VAC (60Hz) (60Hz) F Weight (kg) 78 94 100 64 75 4.2 x 7 (Long hole) 1.5 104 122 134 75 114 4.2 x 9 (Long hole) 4 F Weight (kg) B C D E -2 C A B OUT PUT Primary Secondary Capacity Model voltage voltage A 220V Part No. VOLUTAGE SELECTOR IN PUT IDF-TR500-2 4-F E D Input cord 2m IDF-TR IDF-TR1000-2 -3, 4 Dryer IDF1D-1 to 11C-1 Single IDU3D-1 to 11C-1 500VA phase Single IDF15C-1 1kVA turn IDU15C-1 200, 220 100VAC 230, 240VAC (50Hz) (50Hz) 100 to 200 to 260VAC 110VAC (60Hz) (60Hz) B C D E 118 140 163 70 112 118 140 208 70 157 6 5.5 x 10 (Long hole) 10 C VOLUTAGE SELECTOR Part No. B FUSE Dryer Capacity Model Primary voltage Secondary voltage A IDF1D-1 to 11C-1 IDU3D-1 to 11C-1 IDF15C-1 IDF-TR1000-3 IDU15C-1 IDF1D to 11C-1 IDF-TR500-4 IDU3D to 11C-1 IDF15C-1 IDF-TR1000-4 IDU15C-1 IDF-TR500-3 IN PUT OUT PUT E D 4-øF A Input cord 2m 500VA Single 1kVA phase Single 500VA turn 1kVA 380, 400, 415VAC (50Hz) 380 to 420VAC (60Hz) 420, 440, 480VAC (50Hz) 420 to 520VAC (60Hz) B C D E F Weight (kg) 15 100VAC (50Hz) 110VAC (60Hz) 22 230 207 190 210 160 9 15 22 IDF-TR1500-5 Terminal block 207 180 ø25 4-ø11 210 Dryer IDF-TR1500-5 IDF22C1-3 IDF37C1-3 IDU22C1-3 IDU37C1-3 Primary voltage Three 220V (50Hz) 1.5kVA phase Single 220 to 240V (60Hz) turn Part No. Secondary voltage Weight (kg) 200V (50Hz) 200 to 220V (60Hz) 9 4-ø11 Primary voltage Secondary voltage A B C Weight (kg) IDF22C1-3, 37C1-3 1.5kVA IDU22C1-3, 37C1-3 380, 400, 415V (50Hz) 380 to 400, 400 to 415, 415 to 440V (60Hz) 200V (50Hz) 275 259 240 18 200 to 220V (60Hz) IDF-TR1500-7 IDF22C1-3, 37C1-3 1.5kVA IDU22C1-3, 37C1-3 440, 460V (50Hz) 440 to 460, 460 to 500V (60Hz) 200V (50Hz) 275 259 240 18 200 to 220V (60Hz) IDF-TR4000-5 IDF55C-3, 75C-3 4kVA IDU55C-3, 75C-3 220V (50Hz) 220 to 240V (60Hz) 200V (50Hz) 275 259 240 14 200 to 220V (60Hz) IDF-TR4000-6 IDF55C-3, 75C-3 4kVA IDU55C-3, 75C-3 380, 400, 415V (50Hz) 380 to 400, 400 to 415, 415 to 440V (60Hz) 200V (50Hz) 355 299 320 35 200 to 220V (60Hz) IDF-TR4000-7 IDF55C-3, 75C-3 4kVA IDU55C-3, 75C-3 440, 460V (50Hz) 440 to 460, 460 to 500V (60Hz) 200V (50Hz) 355 299 320 42 200 to 220V (60Hz) -8 C E B øG A D Primary Secondary Capacity Model voltage A voltage Part No. Dryer IDF-TR7000-8 IDF120D 7kVA IDF-TR9000-8 IDF150D 9kVA IDF-TR11000-8 IDF190D 11kVA IDF-TR13000-8 IDF240D 13kVA IDF-TR18000-8 IDF370B 18kVA Three phase compound IDF-TR 220 Capacity Model IDF-TR1500-6 ø30 A Dryer Three phase Single turn Terminal block B C 4-øF Capacity Model -5, 6, 7 45 IDF-TR 160 Part No. 220, 240, 380, 400, 415, 440V (50/60Hz) F G 360 540 400 260 300 11 30 B C D E 400 650 450 300 350 13 200V (50/60Hz) 550 450 600 350 400 13 400 600 450 300 350 13 400 650 450 300 350 13 Weight (kg) 94 40 109 60 131 60 138 40 179 22 Accessories (Options) Base Integrated with Transformer Part No. Dryer IDF4D-1 IDF-TB1 IDF6D-1 B 75 A IDU3D-1 Transformer separately installed 14 E IDF8D-1 D G C 65 (F) H 4-ø13 IDF11C-1 Base integrated with transformer IDF15C-1 IDF-TB2 IDU4D-1 Part No. Dryer IDF-TB3 IDF22C1 IDF37C1 IDF-TB4 IDF55C IDF75C Transformer IDF-TR1500-5 IDF-TR1500-6 IDF-TR1500-7 IDF-TR1500-5 IDF-TR1500-6 IDF-TR1500-7 IDF-TR4000-5 IDF-TR4000-6 IDF-TR4000-7 IDF-TR4000-5 IDF-TR4000-6 IDF-TR4000-7 A B C D E 327 755 628 600 379 F G H Weight (kg) 83 95 327 805 379 708 680 419 728 700 379 975 419 IDU8D-1 104 51 69 675 805 379 925 IDU6D-1 92 728 700 142 163 170 154 175 182 IDU11C-1 IDU15C-1 Transformer IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR1000-1 IDF-TR1000-2 IDF-TR1000-3.4 IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR500-1 IDF-TR500-2 IDF-TR500-3.4 IDF-TR1000-1 IDF-TR1000-2 IDF-TR1000-3.4 A 681 584 595 595 645 695 681 785 885 985 1035 B 171 217 284 171 217 284 171 217 284 171 217 284 171 217 284 199 217 284 171 217 284 171 217 284 171 217 284 171 217 284 199 217 284 C D E 356 328 53 376 348 470 442 470 442 55 490 462 490 462 466 438 53 470 442 470 442 55 490 462 490 462 F – – – – – – G H Weight (kg) 33 37 46 30 34 43 39 44 53 39 44 53 69 54 59 68 60 427 557 66 78 38 – – 43 – 52 50 55 64 54 59 68 69 66 71 80 76 82 94 Note) Weight includes air dryer and transformer. Not available for IDF1D to 3D, IDU22C to 75C. Dust proof filter set (A) (25) (10) (B) (25) IDF-FL1C, 2C, 3C, 4C, IDU-FL3C, 4C (IDF-FL6C, 8C, 11C, 15C) 23 Part No. IDF-FL1C IDF-FL2C IDF-FL3C IDF-FL4C IDF-FL6C IDF-FL8C IDF-FL11C IDF-FL15C IDF-FL22C IDF-FL37C IDF-FL55C IDF-FL75C Dryer IDF1D IDF2D IDF3D IDF4D IDF6D IDF8D IDF11C IDF15C IDF22C1 IDF37C1 IDF55C IDF75C IDF-FL120D IDF120D IDF-FL150D IDF150D IDF-FL190D IDF190D IDF-FL240D IDF240D A 180 180 225 225 345 345 365 385 430 555 600 640 360 440 360 440 250 750 440 600 B 145 145 180 180 270 270 270 310 310 380 410 510 420 420 420 420 480 480 670 670 Part No. IDU-FL3C IDU-FL4C Dryer IDU3D IDU4D IDU-FL6C IDU6D IDU-FL8C IDU8D IDU-FL11C IDU11C IDU-FL15C IDU15C IDU-FL22C IDU22C1 IDU-FL37C IDU37C1 IDU-FL55C IDU55C IDU-FL75C IDU75C A 245 240 400 345 405 345 395 365 395 385 480 430 605 555 605 600 625 640 B 265 300 170 270 270 310 270 310 430 310 475 345 475 410 550 510 For IDU-FL6C to 75C, 2 pcs. are 1 set. For IDF-FL120D to 240D, 2 pcs. are 1 set. Accessories (Options) Bypass Piping Set IDU3D, 4D IDF1D, 2D, 3D, 4D Compressed air inlet Compressed air inlet Compressed air outlet Port size (B) (A) Port size (B) (C) (C) (A) Compressed air outlet Part No. Applicable dryer IDU-BP3C IDU3D IDU-BP4C IDU4D Port size Rc 3/8 Applicable dryer IDF-BP1C IDF-BP2C B C IDF1D 34 112 563 IDF2D 62 112 571 57 112 632 66 112 792 B C 77 112 706 IDF-BP3C IDF3D 66 112 791 IDF-BP4C IDF4D Compressed air outlet Port size Rc A A IDU6D, 8D, 11C, 15C, 22C1, 37C1, 55C, 75C (E) Part No. 3/8 IDF6D, 8D, 11C, 15C, 22C1, 37C1, 55C, 75C Compressed air inlet Compressed air outlet Port size (A) (D) Compressed air inlet Port size (E) (D) (C) (C) (B) (B) (A) Part No. Applicable dryer Port size Rc A B C D E Part No. Applicable dryer Port size Rc A B C D E 725 120 755 120 141 152 222 815 131 890 131 405 222 970 91 183 405 98 208 405 280 1075 325 1240 98 85 405 325 1290 98 85 IDU-BP6C IDU6D 1/2 445 165 915 85 141 IDF-BP6C IDF6D 1/2 410 165 IDU-BP8C IDU8D 3/4 445 196 1045 85 141 IDF-BP8C IDF8D 3/4 410 196 IDU-BP11C IDU11C 445 196 1155 91 152 IDF-BP11C IDF11C 196 IDU15C 445 222 1230 91 175 IDF-BP15C IDF15C 3/4 1 405 IDU-BP15C 3/4 1 405 IDU-BP22C IDU22C1 1 445 222 1445 70 71 IDF-BP22C IDF22C1 1 IDU-BP37C IDU37C1 550 IDF-BP37C IDF37C1 IDU55C 530 280 1615 136 325 1750 155 112 IDU-BP55C 1 1/2 2 87 IDF-BP55C IDF55C 1 1/2 2 IDU-BP75C IDU75C 2 530 325 1885 220 87 IDF-BP75C IDF75C 2 141 175 Cannot be mounted on models with option "A". 24 Technical Data ssure Pressure dew point — Condensed water calculation pheric pre 0.7 0.8 30 0.3 0.4 0.5 0.6 Pa 0.2 0.1M 35 25 20 1.0 Amount of condensed water 18.2 – 3.0 = 15.2g/m³ 1.5 20% Atmos Amount of water in air g /m³ 40% 60% 40 Relat ive h umid ity 80 % 100% 45 15 10 5 3.0 0 –20 –10 0 10 20 30 40 50 60 Intake air temperature °C (atmospheric pressure) 0 10 20 30 40 50 60 70 80 Air temperature (Pressure dew point) °C [Example] If air at 30°C and 60% humidity is pressurized to 0.7MPa, the dew point of the air will be 62°C. ( ) If this is cooled to 25°C, the amount of condensed water generated will be 15.2g/m³. ( ) Therefore, with an air flow rate of 3m³/min (22kW equivalent compressor), the amount of condensed water per unit of time is 15.2 x 3 x 60 = 2736g/h. Dew point conversion chart 60 50 40 Pressure dew point °C 30 20 10 1.5MPa 1.3MPa 1.1MPa 0.9MPa 0.7MPa 0.5MPa 0.3MPa 0.1MPa Atmospheric pressure 0 –10 –20 –30 –40 –50 –60 –60 –50 –40 –30 –20 –10 0 10 Atmospheric pressure dew point °C 25 20 30 Series IDU/IDF Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by a label of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices. Caution : Operator error could result in injury or equipment damage. Warning : Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possible result of serious injury or loss of life. Note 1) ISO 4414: Pneumatic fluid power -- Recommendations for the application of equipment to transmission and control systems Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. 2. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 2. When equipment is to be removed, first confirm the safety process as mentioned above. 3. Before machinery/equipment is restarted, first confirm that safety measures are implemented, and proceed with caution. 4. Contact SMC if the product is to be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 26 IDU/IDF Air Preparation Equipment Precautions 1 Series Be sure to read before handling. Selection Precautions on Design Employ a safe design so that the following type of unexpected conditions will not occur. Caution 1. Do not allow flow greater than the rated flow rate. Warning 1. Design so that high temperature compressed air does not flow to pneumatic equipment. In case of cooling equipment failure (stoppage of cooling water in water cooled type after cooler, stoppage of fan motor in air cooled type after cooler, etc.) on the air supply side, high temperature compressed air can flow downstream and cause damage or malfunction of downstream equipment. 2. Use a design that allows for stoppage of the compressed air supply. Compressed air flow may be stopped by freezing of a refrigerated air dryer or malfunction of the switching valve (heatless dryer). Caution If the flow exceeds the rated flow rate even momentarily, this can cause drainage and oil to be sprayed downstream or cause damage, etc. 2. The product cannot be used with low pressure air (blowers). Operating below the minimum operating pressure can cause reduced performance and malfunction. If this type of use is unavoidable, contact SMC in advance. Mounting Caution 1. Confirm the mounting orientation. 1. Use a design that prevents reverse pressure and back flow. Reverse pressure and back flow can cause equipment damage or malfunction, etc. Give attention to safety measures, including handling procedures. Selection Since the mounting orientation is different for each piece of equipment, this should be confirmed either in this catalog or in the instruction manual. Mounting in a tilted orientation can cause faulty drainage discharge, auto drain malfunction and damage in some types of equipment. 2. Ensure suffient maintenance space. When installing and mounting, be sure to allow the space required for maintenance and inspections. Confirm the necessary maintenance space in the instruction manual for each piece of equipment. Warning 1. When selecting equipment, first adequately confirm the purpose for which it will be used, the required specifications and the operating conditions (pressure, flow rate, temperature, environment), etc. Then select equipment from the latest catalogs without exceeding the specification ranges. Contact SMC in advance regarding any questions. 2. Do not use for caisson shields, breathing, medical treatment or for blowing of medicine or food products which will enter the human body. This cleaning equipment is exclusively for use with industrial compressed air, and should not be used for other applications. If other application is unavoidable, give attention to safety measures and contact SMC in advance. 3. This product cannot be used on board vehicles or vessels. This product cannot be used on board vehicles, vessels or other transportation devices, because vibration will cause damage. If this type of use is unavoidable, contact SMC in advance. 27 Piping Caution 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil and other debris from inside the pipe. 2. Wrapping of pipe tape When screwing together pipes and fittings, etc., be certain that chips from the pipe threads and sealing material do not get inside the piping. Furthermore, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. 3. Implement measures to prevent drainage from collecting inside piping. Drains should be installed in the lower sections of piping that rises, or piping should be designed with a slight taper provided along the direction of flow so that drainage will not accumulate. 4. Confirm IN and Out ports. When piping is being installed, take care to prevent incorrect connection of the water and air sides, or the IN and OUT ports. IDU/IDF Air Preparation Equipment Precautions 2 Series Be sure to read before handling. Maintenance Air Supply Warning Warning 1. Do not use with fluids other than compressed air. 1. If an abnormality occurs, stop the compressed air. Cleaning equipment is designed exclusively for use with compressed air. Contact SMC in advance if a fluid other than compressed air is to be used. If abnormalities such as smoke, unusual odor or unusual noise occur, stop the inflow of compressed air, as this may indicate a fire. 2. Do not use compressed air which contains chemicals, organic solvents or corrosive gases. 2. When performing inspections, set the compressed air pressure at zero. Do not use compressed air containing chemicals, organic solvents, salt or corrosive gases, as this can cause damage and/or malfunction, etc. 3. Use within the operating pressure range. The operating pressure range is determined by the equipment being used. Operation beyond this range can cause damage, failure or malfunction. Operating Environment Warning 1. Do not use in the following environments, as this can cause failure. 1. Locations with an atmosphere of corrosive gases, organic solvents or chemical solutions, or where there may be contact with these. 2. Locations where there is contact with sea spray, water or steam. 3. Locations which receive direct sunlight. (Sunlight should be blocked to prevent deterioration of resin from ultra violet rays, and over heating, etc.) 4. Locations near heat sources with poor ventilation. (Heat sources should be blocked off, because radiated heat may cause damage due to softening of materials.) 5. Locations with impacts or vibration. (Check the specifications for each series.) 6. Locations with high moisture and dust. (Contact SMC in advance.) When the compressed air side is to be disassembled for auto drain inspection, separator element replacement or film module replacement, etc., confirm that the pressure is at zero before proceeding. Caution 1. Do not place heavy objects on the unit or use it as a step. The equipment may be deformed or damaged, and if balance is lost, falling may cause injury. 2. Discharge drainage regularly. Accumulation of drainage in equipment, piping or other areas can cause malfunction of the equipment or unexpected trouble due to splash over into the downstream side, etc. Therefore, the amount of drainage and the operation of auto drains should be checked every day. 2. Adhere to the fluid and ambient temperature ranges. The fluid and ambient temperatures are determined by the equipment being used. Operation outside of the prescribed range can cause damage, failure or malfunction, etc. 28 Series IDU/IDF Specific Product Precautions 1 Air Preparation Equipment Precautions Refer to pages 26 through 28 for safety instructions and cleaning equipment precautions. Power Supply Installation Location Caution Caution • Avoid locations where the air dryer will be in direct contact with wind and rain. (Places where relative humidity is more than 85%) • Avoid exposure to direct sunlight. • Avoid dusty or corrosive environments. Wind If it is used in Rain the above environments, select option C (with anticorrosive treatment). Dust Corrosive gas <100VAC> • Insert the power supply plug into an exclusive 100VAC power outlet. • Install a circuit breaker (10A)∗ at the power supply. • Be sure to ground the power supply prior to use. • Multiple-branch wiring is dangerous as it causes over-heating. • Do not extend the power supply cord length using an extension cord. A voltage drop may cause the air dryer to stop operating. ∗ Use a circuit breaker having a sensitivity current of 30mA or less and a rated current of 10A. Install circuit breaker (10A) Exclusive 100V power outlet • Avoid places with poor ventilation and high temperature. • Allow ample space around the air dryer. Away from the wall ! Grounding <200VAC> • Connect the power supply to the terminal block. • Install a suitable circuit breaker applicable to each model. When the voltage used is other than specified in the standard product specifications, use a transformer (page 21). • Avoid locations subjected to vibrations. • Avoid locations where drainage can freeze. Use the air dryer with an ambient temperature lower than 40°C. Air Piping Caution • Be careful to avoid errors in connecting the air piping to the compressed air inlet (IN) and outlet (OUT). • Install bypass piping which it is needed for maintenance. Bypass valve closed Compressed air inlet Valve open Compressed air outlet Valve open IDF1D to 4D IDU3D, 4D Valve closed • Avoid installation on moving objects like trucks, ships, and so forth. Valve open Drain Tube Caution • A polyurethane tube of 10mm outer diameter is attached as the drain tube for IDF1D to 4D and IDU3D, 4D. Use this tube to discharge drainage. • Do not use the drain tube in an upward direction. Do not bend or crush the drain tube. (Operation of auto drain will stop and water will flow out through the air outlet.) 29 IDF6D to 75C IDU6D to 75C • When tightening piping at the air inlet/outlet tube, the nozzle should be held firmly with a pipe wrench. (IDF6D to 75C, IDU6D to 75C) • Variation of operating conditions may cause condensate to form on the surface of the outlet piping. In the case of models larger than IDF6D and IDU6D, roll thermal insulation around piping to prevent condensate from forming. • Vibration caused by the compressor should not be transmitted through air piping to the air dryer. • Do not allow the weight of piping to be applied directly to the air dryer. Series IDU/IDF Specific Product Precautions 2 Air Preparation Equipment Precautions Refer to pages 26 through 28 for safety instructions and cleaning equipment precautions. Protection Circuit Time Delay for Restarting Caution Caution When the air dryer is operated under the following conditions, the protection circuit is activated, the light goes off and operation stops. • When compressed air temperature is too high • When compressed air flow rate is too high • When ambient temperature is too high (40°C or higher) • When power supply is beyond rated voltage by ±10% • When ventilation port is obstructed by a wall or clogged with dust Compressor Air Delivery Allow at least three minutes before restarting the dryer. If the air dryer is restarted within three minutes after being stopped, the protection circuit will be activated, the operating light goes off and the dryer will not be activated. Please wait three minutes! Crank Case Heater Caution Caution Use an air compressor of 100 l/min or greater air delivery with IDF2D to 4D/IDU3D, 4D, and 300 l/min or greater air delivery with IDF6D to 75C/IDU6D to 75C. A crank case heater is installed on IDF370B. Energize the crank case heater 12 hours prior to operation of the dryer to prevent trouble occurring in the refrigerant compressor. Since the auto drain of IDF2D to 75C/IDU3D to 75C is designed in such a way that the valve remains open unless the air pressure rises to 0.15MPa or higher, air will blow out from the drain discharge port when the air compressor starts up until the pressure increases. Therefore, if an air compressor has a low air delivery, the pressure may not be sufficient. Auto Drain Caution The auto drain may not function properly, depending on the quality of compressed air. Check its operation once a day. Cleaning of Ventilation Area Caution Remove dust from the ventilation area once a month using a vacuum cleaner or an air blow nozzle. 30 SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE EUROPE NORTH AMERICA AUSTRIA SMC Pneumatik GmbH CZECH SMC Czech s.r.o. DENMARK SMC Pneumatik A/S FINLAND SMC Pneumatiikka OY FRANCE SMC Pneumatique SA GERMANY SMC Pneumatik GmbH HUNGARY SMC Hungary Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. NETHERLANDS SMC Pnuematics BV. NORWAY SMC Pneumatics Norway A/S ROMANIA SMC Romania s.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Slovakia s.r.o. SLOVENIA SMC Slovenia d.o.o. SPAIN/PORTUGAL SMC España, S.A. SWEDEN SMC Pneumatics Sweden AB SWITZERLAND SMC Pneumatik AG. UK SMC Pneumatics (U.K.) Ltd. CANADA SMC Pneumatics (Canada) Ltd. MEXICO SMC Corporation (Mexico) S.A. de C.V. USA SMC Pneumatics, Inc. ASIA CHINA SMC (China) Co., Ltd. HONG KONG SMC Pneumatics (Hong Kong) Ltd. INDIA SMC Pneumatics (India) Pvt. Ltd. MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. PHILIPPINES SMC Pneumatics (Philippines), Inc. SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. TAIWAN SMC Pneumatics (Taiwan) Co., Ltd. THAILAND SMC Thailand Ltd. SOUTH AMERICA ARGENTINA SMC Argentina S.A. BOLIVIA SMC Pneumatics Bolivia S.R.L. BRAZIL SMC Pneumaticos Do Brazil Ltda. CHILE SMC Pneumatics (Chile) S.A. VENEZUELA SMC Neumatica Venezuela S.A. OCEANIA AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.Z.) Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-0004, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com © 2000 SMC CORPORATION All Rights Reserved 1st printing June, 2000 D-SMC.L.A. P-80 (YG) Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. Printed in Japan.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement