AVPTC

M

ulTi

-P

osiTion

, V

AriAble

-s

Peed

A

ir

H

Andler

To

5 T

ons

Standard Features

• Compatible with the ComfortNet Communicating

System family of products

• R-410A refrigerant-compatible

• Factory-installed thermal expansion valves for cooling and heat pump applications

• Variable-speed ECM blower motor

• All-aluminum evaporator coil

• Provides constant CFM over a wide range of static pressure conditions independent of duct system; provides low CFM for efficient fan-only operation

• In non-communicating mode, up to 12 field-selectable airflow settings can be adjusted to optimize the system’s CFM for each individual mode of operation

• Auto configuration of the airflow and tonnage in communicating mode

• CFM indicator

• Maximum four low-voltage wires required for operation in communicating mode

• Improved humidity control and comfort

• Compatible with heat pumps and variable-capacity cooling applications

• Built-in coil has horizontal, vertical, and downflow drain pans with secondary drain connections

• Complies with the Factory-sealed Air Handling Credit with or without field-installed filter kits as listed in the 2001

Florida Building Code, Chapter 13, Section 610.2.A.2.1

• AHRI Certified; ETL Listed

Cabinet Features

• Fully insulated, painted steel cabinet with attractive

Architectural Gray finish

• Compact, versatile upflow, downflow, or horizontal multiposition installations

• Built-in filter rack for 1” filter (filter not included)

• Low-voltage cabinet connections; control circuit is arranged to permit staging

• Power supply on top; low-voltage entry on top or side

• Factory-sealed to achieve 2% or less leakage rate with or without field-installed filter kits at 1.0” water gauge external duct static pressure

SS-AAVPTC

* Complete warranty details available from your local dealer or at www.amana-hac.com.

To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

www.amana-hac.com

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P., Houston, Texas.

5/11

Supersedes 2/11

P roduCT

s

PeCifiCATions n

oMenClATure

 

A

1

Brand

A Single-­‐piece

Air  Handler

R

S

V

D

E

Unit  Applica3on

C Ceiling  Mount  PSC  Motor

Downflow  PSC  Motor

MulI-­‐PosiIon  Variable-­‐Speed  Motor

MulI-­‐PosiIon  PSC  Motor

MulI-­‐PosiIon  EEM  Motor

MulI-­‐PosiIon  Variable-­‐Speed  Motor

W Wall  Mount  PSC  Motor

P

N

Cabinet  Finish

U Unpainted

Painted

Uncased

Expansion  Device

F Flowrater

T Expansion  Valve

V

2

P

3

T

4

C

5

3642

6,7,8,9

1

10

4

11

AA

12,13

Engineering  *

Major/  Minor  Revisions

*    Not  used  for  inventory  management

Refrigerant  Compatability

4  =  R-­‐410A  

Electrical

1      208/240  V,  1  Phase,  60  Hz

Nominal  Capacity  Range  @  13  SEER

Mul3-­‐Posi3on  &  Downflow  Applica3ons

1830      1½-­‐2½  Tons

3137      2-­‐3  Tons

4260      3-­‐5  Tons

Communica3ons

C ComfortNet™  CompaIble

P roduCT

s

PeCifiCATions

SS-AAVPTC www.amana-hac.com 3

P roduCT

s

PeCifiCATions s

PeCifiCATions

Nominal Ratings

Cooling (BTU/h)

CFM (High/ Low)

Blower

Diameter

Width

Coil Drain Connection FPT

Service Valve

Liquid

Suction

Electrical Data

Voltage

Electric Heat Capacity (kW)

Min Circuit Ampacity

Max. Overcurrent Device (amps)

Minimum VAC

Maximum VAC

Blower Motor

FLA

HP

Ship Weight (lbs)

AVPTC

183014

18,000-30,000

1,200/ 600

9½"

8"

¾"

⅜"

¾"

208/240

3, 5, 8, 10

4.9/4.9

15/15

197

253

3.9

½

127

AVPTC

313714

30,000-36-000

1,200/ 600

10⅝"

10⅝"

¾"

⅜"

⅞"

208/240

3, 5, 6, 8,10, 15

6.5/6.5

15/15

197

253

5.2

¾

178

AVPTC

426014

42,000-60,000

1,800/ 1,200

10⅝"

10⅝"

¾"

⅜"

⅞"

208/240

3,5,6,8,10,15,20,21

8.6/8.6

15/15

197

253

6.9

1

197

P roduCT

s

PeCifiCATions

SS-AAVPTC www.amana-hac.com 3

P roduCT

s

PeCifiCATions d

iMensions

Model

AVPTC183014

AVPTC313714

AVPTC426014

A

46¾”

53¼”

53¼”

B

22”

24”

24”

C

17½”

20”

20”

D

19½”

22”

22”

E

10”

12”

12”

F G H I

14½” 11 15 /

16

” 17⅛” 17 15 /

16

J

2”

14½” 11 15 /

16

” 19⅝” 19 15 /

16

” 1 13 /

16

14½” 11 15 /

16

” 19⅝” 19 15 /

16

” 1 13 /

16

P roduCT

s

PeCifiCATions

SS-AAVPTC www.amana-hac.com 5

P roduCT

s

PeCifiCATions

P roduCT

s

PeCifiCATions

A

irflow

d

ATA

Electric Heat Airflow

Htr kW

3

5

6

8

10

15

20

21

9

ON

ON

ON

ON

OFF

OFF

OFF

OFF

10

ON

ON

OFF

OFF

ON

ON

OFF

OFF

11

ON

OFF

ON

OFF

ON

OFF

ON

OFF

AVPTC

183014*

630

730

840

1080

1270

NR

NR

NR

AVPTC

313714*

610

710

840

1060

1260

1470

NR

NR

AVPTC

426014*

600

680

790

990

1190

1390

1580

1580

Note: Airflow data shown applies to the emergency heat mode (electric heat only) in either legacy mode operation or fully communicating mode operation.

Model

AVPTC183014*

AVPTC313714*

AVPTC426014*

Cooling / Heat Pump Airflow

Tap

A

B

C

A

B

C

D

A

B

C

D

Low-Stage

Cool

420

560

700

410

560

700

830

810

940

1050

1210

High-Stage

Cool

630

840

1040

610

830

1040

1240

1210

1410

1560

1800

Notes

• Airflow data shown applies to legacy mode operation only. For a fully communicating system, see the outdoor unit’s installation instructions for cooling and heat pump airflow data. See ComfortNet™ System —

Airflow Consideration section for details.

• Airflow blink codes are approximations a=of actual airflow.

d

iPswiTCH

s

eTTings

Speed Selection Dipswitches

Tap

C

D

A

B

Cool

Switches

1 2

Switches

3

Adjust

4

Profile

Switches

5 6

Off Off Off Off Off Off

On Off On Off On Off

Off On Off On Off On

On On On On On On

Profiles

A

B

C

D

Pre-Run

-----

-----

-----

30 sec / 50%

Short-Run

-----

30 sec / 50%

7.5 min / 82%

7.5 min / 82%

OFF Delay

60 sec / 100%

60 sec / 100%

60 sec / 100%

30 sec / 50%

To set airflow:

1. Select appropriate model from Cooling/Heat Pump Airflow Table. Based on desired Airflow for your application select corresponding tap (A,B,C or D). Set dip switches 1 & 2 to the appropriate ON/OFF positions.

2. Select appropriate Airflow adjustment factor for application (0%. +10%, -10%). Set dip switches 3 & 4 to the appropriate ON/OFF positions.

3. If installed with Heater Kit: Using Electric Heat Airflow Table, set dip switches 9, 10 and 11 to the appropriate ON/OFF positions based on Heater kit installed. If installed without Heater Kit: Ensure dip switches 9, 10 and 11 are set to a valid heater kit selection. Example: The only valid heater kits for

AVPTC183014* applications are 3, 5, 6, 8 and 10 kW. Failure to do so will result in a Heater Kit error code.

To set Comfort mode: Select desired Comfort Mode profile (see profiles above). Set switches 5 and 6 to the appropriate ON/OFF positions.

SS-AAVPTC www.amana-hac.com 5

P roduCT

s

PeCifiCATions

AVPTC w

iring

d

iAgrAM

1

2

3

4

K G

BIAS

BIAS

TERM

CONNECTOR

CUIT MOTOR 4 CIR

COOL

ADJUST

DELAY

DEHUM

UNUSED

ELEC

HEAT

AF

NS IO CT NE ON

NS TIO NEC ON T C STA MO HER V T 24

T C TA OS RM HE V T 24

1

4

3

2

P roduCT

s

PeCifiCATions

Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring.

W

arning

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.

SS-AAVPTC www.amana-hac.com 7

P roduCT

s

PeCifiCATions

P roduCT

s

PeCifiCATions

A

CCessories

H eAT

K iT

s eleCTion

Models

HKR-03*

HKR-05*/-05C*

HKR-06*

HKR-08*/-08C*

HKR-10*/-10C*

HKR-15C*

HKR-20C*

HKR-21C*

AVPTC

183014A*

X

X

X

X

AVPTC

313714*

X

X

X

X

X

AVPTC

426014A*

X

X

X

X

X

X

* Revision level that may or may not be designated

C Circuit breaker option

Notes:

When 8kW and 10kW heat kits are used with an AVPTC1830 and AVPTC3137, matched with

2- ton outdoor unit, see Note 1 below.

¹ Set Heater Kit dip switches 9, 10 and 11 to 6kW setting (9-ON, 10-OFF,11-ON) to obtain

840 CFM.

² This heater kit can only be used for ‘1000 CFM or higher’ applications.

³ This heater kit can only be used for ‘1200 CFM or higher’ applications.

d rAin

P

An

i nsulATion

K iTs

Downflow Applications

1830

Model

3137-4260

Insulation Kit

DPI36-42/20

DPI48-61/20

Note: Each kit contains enough material to modify 20 coils

Horizontal Applications

1830

Model

3137-4260

Insulation Kit

DPIH36-42

DPIH48-61

Note: Each kit contains enough material to modify 20 coils s ingle

P oinT

K iT

**

Model HKR-15C HKR-20C HKR-21C

SPW-01 X X X

** Must be installed along with any of the above compatible heat kits. This kit will fit any AVPTC air handler as long as a compatible heat kit is installed in the unit.

f ilTers

Model

N/A

1830

3137

4260

Filter #

FIL 18-32

FIL-36-42

FIL 48-61

FIL 48-61

Qty

Required

1

1

1

1

SS-AAVPTC www.amana-hac.com 7

P roduCT

s

PeCifiCATions n

oTes

P roduCT

s

PeCifiCATions

Amana® is a trademark of Maytag Corporation or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our continuing commitment to quality products may mean a change in specifications without notice. © 2011 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.

SS-AAVPTC www.amana-hac.com PB

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement