Instruction Manual

Model 8025 Series Datalogger

(Micro-800)

Multi-Channel Datalogger

No part of this instruction manual may be reproduced, by any means, without the written consent of Geokon, Inc.

The information contained herein is believed to be accurate and reliable. However, Geokon, Inc. assumes no responsibility for errors, omissions or misinterpretation. The information herein is subject to change without notification.

Copyright © 2013 by Geokon, Inc.

(Doc Rev I, 8/13)

Warranty Statement

Geokon, Inc. warrants its products to be free of defects in materials and workmanship, under normal use and service for a period of 13 months from date of purchase. If the unit should malfunction, it must be returned to the factory for evaluation, freight prepaid. Upon examination by Geokon, if the unit is found to be defective, it will be repaired or replaced at no charge.

However, the WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of being damaged as a result of excessive corrosion or current, heat, moisture or vibration, improper specification, misapplication, misuse or other operating conditions outside of

Geokon’s control. Components which wear or which are damaged by misuse are not warranted.

This includes fuses and batteries.

Geokon manufactures scientific instruments whose misuse is potentially dangerous. The instruments are intended to be installed and used only by qualified personnel. There are no warranties except as stated herein. There are no other warranties, expressed or implied, including but not limited to the implied warranties of merchantability and of fitness for a particular purpose. Geokon, Inc. is not responsible for any damages or losses caused to other equipment, whether direct, indirect, incidental, special or consequential which the purchaser may experience as a result of the installation or use of the product. The buyer’s sole remedy for any breach of this agreement by Geokon, Inc. or any breach of any warranty by Geokon, Inc. shall not exceed the purchase price paid by the purchaser to Geokon, Inc. for the unit or units, or equipment directly affected by such breach. Under no circumstances will Geokon reimburse the claimant for loss incurred in removing and/or reinstalling equipment.

Every precaution for accuracy has been taken in the preparation of manuals and/or software, however, Geokon, Inc. neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages or losses that result from the use of the products in accordance with the information contained in the manual or software.

Table of Contents

Overview .............................................................. 1

1. Hardware …………………………………….. 1

1.1 Installation ………………………….. 2

1.2 Power ……………………………….. 2

1.3 Earth Ground ……………………….. 2

1.4 Gages ……………………………….. 3

1.5 Communications ……...…………….. 3

2. Software ………………………………........... 3

3. Battery Maintenance …………………………. 4

3.1 AC Power …………………………... 4

3.2 Solar Power ………………………… 4

3.3 External Battery …………………….. 4

3.4 Battery Replacement ………………... 4

3.5 Fuses ………………………………... 4

4. Troubleshooting ……………………………… 5

Appendix

Appendix A - Specifications

A.1 CR800 Measurement and Control Module ….....……... 7

A.1.1 Analog Inputs ………………………………………. 7

A.1.2 Excitation Outputs ………………………….............. 7

A.1.3 Pulse Inputs …………………………………………. 7

A.1.4 Control Ports ……………………………………...… 8

A.1.5 Model 8032 Multiplexer ……………………………. 8

A.1.6 AVW200 Vibrating Wire Interface ………………… 8

Appendix B – Ship List

B.1 Hardware ……………………………………………… 8

Appendix C – Data Storage

C.1 Input Locations ……………………………………….. 9

C.2 Data Storage ………………………………………….. 10

C.3 Data Storage Example ………………………………... 10

Appendix D - System Wiring

D.1 CR800 Wiring (8025-2, 8025-3 and 8025-4) ………..... 11

D.1.1 AVW200 Wiring (8025-2, 8025-3 and 8025-4) …… 11

D.1.2 CR800 Wiring (8025-5) ..…………………………… 12

D.1.3 RS-232 Connector Wiring ………………………...... 12

D.1.4 Charger Wiring …………………………………….. 13

D.2.1 AC Charger ………………………………………… 13

D.2.2 External Power Cable ……………………………… 13

D.3 Fuses ..………………………………………………… 13

D.4 Multiplexer Connector Wiring .…………………...….. 14

Appendix E – LoggerNet QuickStart Guide ……………………… 15

Appendix F – 8032 Multiplexer Manual ………………………….. 26

Figures

Figure 1 - Typical MICRO-800 Configuration ..………………….. 2

Figure 2 – Charge Regulation Circuit Board ……………………… 2

Figure 3 – Typical Bottom View MICRO-800 .…………………... 3

1

OVERVIEW

The MICRO-800 Datalogger is designed to support the reading of a large number of Geokon

Vibrating Wire Instruments for various unattended data collection applications through the use of an internal Geokon Model 8032 Multiplexer. Weatherproof packaging allows the unit to be installed in field environments where inhospitable conditions prevail. The Nema 4X enclosure also has a provision for locking to limit access to responsible field personnel.

A basic datalogging system consists of the Campbell Scientific CR800 datalogger, an internal multiplexer and an External Multiplexer port. Multiplexers expand the system by increments of

16 or 32 channels depending on the instrument type and configuration. The standard model

8025-2 Micro-800 datalogger can support one (1) internal Multiplexer and (1) external

Multiplexer. The External Multiplexer port can also be used to Daisychain up to eight (8)

Multiplexers (please see 8032 Manual for more information). The standard model 8025-4 and

8025-5 dataloggers are identical to the model 8025-2, but are configured for 32 VW gages only

(8025-4) or 32 Thermistors only (8025-5). The standard model 8025-3 Micro-800 datalogger can support two (2) internal 16 channel Muliplexers and has 32 cable enties.

1.0 HARDWARE

The controller portion of the MICRO-800 datalogger consists of a Campbell Scientific CR800

Measurement and Control Datalogger. To gain an understanding on the workings and capabilities of the CR800 it is necessary to read the Overview section of the CR800 Operator’s Manual. The

CR800 Operator’s Manual is available as a pdf file on the Campbell Scientific Resource CD supplied with the datalogger.

A Campbell Scientific AVW200 Vibrating Wire Interface provides the required excitation and signal processing for the vibrating wire sensors connected to the Datalogger. The AVW200 uses spectral analysis to find the resonant frequency of the Vibrating Wire Gage. The AVW200 is also used to measure the thermistor used in Geokon’s vibrating wire instruments. For complete specifications of the AVW200 see the AVW200 Instruction Manual on the Campbell Scientific

Resource CD.

A dual-mode battery charging circuit board is used to provide the charging voltage for proper maintenance of the installed lead acid battery. The circuit board contains fused protected terminal blocks used to provide a nominal 12VDC supply for devices such as the CR800 and

Model 8032 Multiplexer board. In some cases a Solar Charge Regulator may be used in place of the dual-mode charger.

The Model 8032 Multiplexer board expands the number of channels that can be read by the

MICRO-800 Datalogger. The channel switching is accomplished by mechanical relays mounted on the underside of the circuit board and the transducer connections are accomplished by friction locking terminals. Power, reset and clocking for the multiplexer are supplied by the MICRO-800.

The Model 8032 multiplexer can be configured for 16x4 or 32x2 channels depending on application. Please see Appendix F for more information on the Geokon Model 8032 multiplexer.

A 12V – 7Ah lead acid battery is used to provide power for the datalogger. The battery is provided to supply operating power for a limited period of time should the AC or solar power, used to maintain the battery, be interrupted. Under normal operating conditions and proper maintenance, the life expectancy of the battery is approximately five (5) years.

2

1.1 INSTALLATION

The recommended method of installation involves attaching the enclosure (MICRO-800) to a fixed structure, such as a wall, in an upright position (Figure 1). Mounting dimensions shown in inches.

Figure 1

1.2 Power

After the Datalogger is installed the charger can be plugged into the AC mains and the On/Off switch S1 on the Charge Regulation circuit board switched to the “On” position (Figure 2). It is recommended that the charger be left plugged in at all times (Section 3.1).

Figure 2

1.3 Earth Ground

An earth grounding lug is supplied on the exterior of the Micro-800 enclosure to connect the system to earth ground (Figure 3). A grounding rod can be driven (or other suitable attachment to earth utilized) to ground the system and provide a path to earth for protection against a lightning strike or other transient voltage. A 6’ to 8’ copper grounding rod connected to the

Dataloggers grounding lug with a large gauge wire (12 AWG or larger) is recommended. The earthing connection should be made as close to the Datalogger as possible.

3

1.4 Gages

At this time the vibrating wire sensors can be connected to the multiplexer. Please refer to

Appendix F for the appropriate connection description.

1.5 Communications

Standard communications with the Datalogger is established by connecting the supplied serial cable to the RS-232 port (Figure 3) and the COM port on a computer, or a USB port on the computer by using the provided USB to Serial converter cable.

Figure 3

2. SOFTWARE

The Micro-800 Datalogger is operated by a download file that is generated by a software program. The software package the MICRO-800 Datalogger may be supplied with is either

MultiLogger software (developed by Canary Systems, Inc, New London, NH) or LoggerNet software (developed by Campbell Scientific, Logan, Utah). Please refer to the manual supplied with the software for instructions on installing the software and creating the required download file for datalogger operation.

4

3. BATTERY MAINTENANCE

3.1 AC Power

The MICRO-800 is supplied with an external AC to DC power supply for maintaining the charge of the battery and providing power to the Datalogger and peripherals. It is imperative that the power supply remain connected to the Datalogger as the battery installed in the Datalogger is only provided as a temporary source of power should the power supply be disconnected or mains power interrupted. Actual run time solely on battery power will vary for each datalogging system, depending on the hardware configuration and sensor scan interval. If the battery voltage drops below 9.6 volts operation of the Datalogger will become erratic as evidenced by communication problems and possible improper measurements.

3.2 Solar Power

If AC mains power is not available, a properly sized solar panel can be used to provide power to maintain the charge state of the battery and provide power to the Datalogger and peripherals. The size of the solar panel is determined by geographic location of the Datalogger, hardware configuration, and the sensor scan interval.

3.3 External Battery

Additionally, a large external battery, such as a deep cycle marine battery, may be connected to the Datalogger via the supplied external power cable to provide power to the Datalogger and peripherals. When this type of battery is connected to the Datalogger the internal Datalogger battery is automatically disconnected from the system to prevent parasitic drain on the external battery.

3.4 Battery Replacement

If the internal Lead Acid Battery has failed it is recommend that the unit be returned to the factory for service by Geokon personnel. However, with skilled personnel and appropriate tools, it is possible for the user to replace the battery. Consult the factory for information.

3.5 Fuses

There are five fuses on the dual mode charger board of the MICRO-800 (Figure 2).

Once removed and with the power switch off, a fuse can be checked visually and with an ohmmeter. A gap may be evident (with some discoloration) if the fuse needs replacing. This can be verified by a high resistance measurement (mega-ohms) with an ohmmeter. If fuse needs replacing, insert one of the supplied replacement fuses. If there are no replacement fuses available, consult the factory or they can be purchased from an electrical supply house. All five fuses are 2 amp SLO-

BLO 5x20mm. Consult Appendix D.3. for fuse assignments.

1.

2.

3.

5

4. TROUBLESHOOTING

This section will NOT attempt to cover all possible problems that could be encountered in the course of Datalogger operations. Consult the factory if other problems arise or remain unresolved.

• Cannot communicate with the Datalogger.

Suggestions:

1. The wrong communication cables are being used or the cables in use are defective.

Consult Appendix D.1.2 to verify cable pinout. Consult the factory for interfacing information.

2. The internal battery could be dead. Charge overnight and try again. If it still doesn’t work check the voltage across the terminals of the battery. If the voltage is still below 10 volts the battery may need to be replaced.

3. The wrong communication port is being used on the host computer (default is COM1).

Consult the appropriate software manual for instructions on changing the communication port.

4. The communication port on the host computer is defective. Verify the functioning and configuration of the COM port by using it with another RS-232 device, such as a modem or serial printer.

5. The Datalogger Auxiliary Fuse on the Dual-Mode Charger board is blown. Refer to

Appendix D.3 for proper fuse replacement.

The system battery voltage and panel temperature read odd numbers.

Suggestions:

1. The system battery could be low. Charge and check again (see previous section).

2. A disruptive current loop may be operating as a result of improper grounding or excessive noise. Consult the factory for more information.

• The internal battery measurement does not increase and charging LED (Yellow =

Charging and Green = Charged) does not light when the AC adaptor is plugged in.

Suggestions:

The adaptor may be damaged. Check the output pins of the adaptor with a voltmeter.

The charger fuse is blown. Consult Section 3.5 for checking and/or replacement.

The internal battery is no good. Consult the factory.

• The Datalogger will not operate on external power.

Suggestions:

6

1. The external voltage supply is below operating limits. If the external source is a battery, charge it. If it’s a power supply, check the output with a voltmeter.

2.

The external power or battery fuse is blown (Section 3.5).

Loss of CR800 program and/or data.

Suggestions:

1. The system has experienced a voltage dropout or surge which disrupted operations.

2. The surge originated as a result of lightning. Install appropriate grounding. Install lightning protection devices on all incoming and outgoing lines (consult factory).

Sensor readings show -99999 or are unstable.

Suggestions:

1. The wrong sensor type has been selected. Check the model number of the sensor against the software setting (Section E.1).

2. The cable(s) to the sensor(s) have been damaged permitting moisture and debris to enter the jacket. Wires may be shorted together. Inspect the cable.

3. If all sensors on a particular multiplexer are erratic or returning “-99999” perhaps the multiplexer or interface cable has been damaged / unplugged.

4. The sensor(s) have been damaged. For example, overrange on a vibrating wire sensor can cause erratic readings.

5. There is an electrical noise source nearby. Move the sensor, cables, and Datalogger away from the noise source. Install grounding devices. Consult the factory.

The sensor readings show OVERRANGE all the time.

Suggestions

1. The “Sensor Type” selected for that particular channel is “None”. This is applicable for users of MultiLogger (Section E.1). Please refer to the MultiLogger manual.

2. A scan has not been initiated yet because of the “Start Time” setting (MultiLogger users only).

3. “Update” has not been run (MultiLogger users only).

7

APPENDIX A - SPECIFICATIONS

A.1 CR800 Measurement and Control Module

Power requirements: 9.6 to 16 VDC

Analog measurement current drain: 27.6 mA

Processing current drain: 16.2 mA

Quiescent current drain: .6 mA

Operating temperature: -25

° to +50° C

Processor: Hitachi H8S 2322

Memory: 2Mb ROM, 4Mb RAM

Storage capacity:2,000,000 Final Storage Locations

Real time clock accuracy:

±3 minutes per year

Expansion capability: up to 2x 32 channel multiplexers (single ended)

System battery: 12 V, 7 Ahr lead acid

Communication: RS-232 115200 baud, 8 data bits, no parity, 1 stop bits

A.1.1 Analog Inputs

Configuration: 3 differential or 6 single-ended

Voltage measurement accuracy: 0.06% of FSR for 0

° to 40°C

Voltage measurement ranges and resolution:

Common mode range:

±5 VDC

DC common mode rejection (CMRR): >100 dB

Maximum input voltage: 16 VDC

A.1.2 Excitation Outputs

Configuration: 2 switched output channels

Excitation range:

±2.5 V

Excitation resolution: 0.67 mV

Excitation accuracy: 0.06% of FSR for 0

°C to 40°C

Output current: 25 mA @ 2.5 VDC

A.1.3 Pulse Inputs

Configuration: two 24 bit

Maximum count rate: 16.7x10^6

Maximum input voltage: +/-20 VDC

Modes: Switch closure, high frequency pulse, low level AC

Range

±5.0 V

±2.5 V

±250 mV

±25 mV

±7.5 mV

±2.5 mV

Resolution

1330

µV

667

µV

66.7

µV

6.7

µV

2

µV

.67

µV

8

A.1.4 Control Ports

Configuration: 4 digital I/O ports

Input/output resistance: 100k

Ω/330Ω, respectively

Input “high” level: 3.8 V to 5.3 V

Input “low” level: -0.3 V to 1.2 V

Output “high” level: 5 V

±0.1 V

Output “low” level: <0.1 V

A.1.5 Model 8032 Multiplexer (See the Appendix F complete specifications)

A.1.6 AVW200 Vibrating Wire Interface (See AVW200 Manual for complete specifications)

Power requirements: 9.6-16 VDC

Vibrating Wire measurement current: 25 mA

Quiescent current: .3 mA

APPENDIX B - SHIP LIST

B.1 Hardware

The following equipment is included with the system:

External Power cable

DB-9 to 10 pin Bendix RS-232 Cable

USB to RS-232 Adapter

Small regular screwdriver

Spare slo-blo fuses (5), 2 amp

AC Adaptor (110 VAC or 220 VAC)

The following manuals are included:

MICRO-800 Instruction Manual

Campbell Scientific Resource disk

Optional accessories:

COM220 Landline Phone Modem with manual (access Datalogger via phone line)

Cellular Phone Modem with manual

Short Haul Modems with manual (current loop communication device)

MD485 RS-485 Multidrop Interface with manual (Datalogger networking)

Solar Panel with mounting hardware, charger, and manuals

RF Modem with manuals (wireless Datalogger communication)

Consult the factory for additional information on any of the optional accessories.

9

APPENDIX C – DATA STORAGE

C.1 Input Locations

Default explanations for the Input/Final Storage location usage in MultiLogger unless user configured;

Input Storage #

1

2

3

4

Label

Logger ID

Year

JulianDay

Time-HHMM

Explanation

Datalogger ID 1-9999

Year when last readings taken

Julian Day (1-365) when last readings taken

Time (24 hour) when last readings taken

5

6

7

Seconds

DecimlDay

ElapsdHr

8

9

10

11

47-78

ElapsdMin

ElapsdSec

Battery

PanelTemp

Mx1

Seconds when last readings taken

Decimal Day when last readings taken

Elapsed Hours from “Start”

(if “Log” selected as “Scan Interval”)

Elapsed Minutes from “Start”

(if”Log” selected as “Scan Interval”)

Elapsed Seconds from “Start”

(if “Log” selected as “Scan Interval”)

Datalogger battery voltage

Datalogger panel temperature (°C)

Readings from Gages on Mux #1

10

C.2 Data Storage

Total Arrays of Data that can be stored per 16 Channel Multiplexer. Each array contains all Data stored at each read interval.

1 Multiplexer Array Storage

2 Multiplexer Array Storage

3 Multiplexer Array Storage

4 Multiplexer Array Storage

5 Multiplexer Array Storage

6 Multiplexer Array Storage

C.3 Data Storage Example

If data is stored once a minute:

Minutes Hours

4,593

Days

1 Multiplexer Overwrite Time: 20,685 344.8 14.4

2 Multiplexer Overwrite Time: 12,244

3 Multiplexer Overwrite Time: 8,722

4 Multiplexer Overwrite Time: 7,633

5 Multiplexer Overwrite Time: 5,450

204.1

145.4

127.2

90.8

Total Arrays

20,700

12,257

8,686

6,701

5,457

8.5

6.1

5.3

3.8

6 Multiplexer Overwrite Time: 4,586

If data is stored once an hour:

Minutes

76.4

Hours

3.2

Days

1 Multiplexer Overwrite Time: 1,241,454 20,690.9 862.1

2 Multiplexer Overwrite Time: 735,407

3 Multiplexer Overwrite Time: 521,196

12,256.8 510.7

8,686.6 361.9

4 Multiplexer Overwrite Time: 403,022

5 Multiplexer Overwrite Time: 327,413

6,717.0

5,456.9

279.9

227.4

Total Arrays

20,700

12,257

8,686

6,701

5,457

4,593

Total Arrays

20,700

12,257

8,686

6,701

5,457

6 Multiplexer Overwrite Time: 275,573

If data is stored once a day:

Minutes

4,592.9

Hours

191.4

Days

4,593

Total Arrays

1 Multiplexer Overwrite Time: 29,795,034 496,583.9 20,691.0 20,700

2 Multiplexer Overwrite Time: 17,650,067 294,167.8 12,257.0 12,257

3 Multiplexer Overwrite Time: 12,507,876 208,464.6 8,686.0 8,686

4 Multiplexer Overwrite Time: 9,651,092 160,851.5 6,702.1 6,701

5 Multiplexer Overwrite Time: 7,858,073 130,967.9 5,457.0 5,457

6 Multiplexer Overwrite Time: 6,613,913 110,231.9 4,593.0 4,593

11

APPENDIX D – SYSTEM WIRING

D.1 CR800 Wiring (8025-2, 8025-3 and 8025-4)

CR800

Connections

AG

12V

G

C1

C2

C3

C4

PWR In +12V

MUX 1

Interface

Cable

MUX 2

Interface

Cable

Green & Black Green & Black

Blue Blue

Violet Violet

Gray

NC

NC

NC

Gray

NC

AVW200 SDI-12 CR800 Power

Interface Cable Cable

NC

NC

Blue’s Black

NC

NC

Blue

NC

NC

NC

NC

NC

NC

White

NC

White

NC

NC

NC

PWR in G NC NC NC

D.1.1 AVW200 Wiring (8025-2, 8025-3 and 8025-4)

NC

Red

Black

Description

Analog Ground

12 VDC Output

Ground

Digital I/O Port 1 / RESET

Digital I/O Port 2 / RESET

Digital I/O Port 3 / SDI-12

Communication

Digital I/O Port 4 / Clock

+12VDC Power

Power Ground

AVW200

Connections

1V +

1V -

1T+

1T-

SCI12

G

12V

G

Color MUX Interface

Ribbon Cable

Brown

Red

Orange

Yellow

Blue

Blue’s Black

Red

Red’s Black

Conductor 1

Conductor 2

Conductor 3

Conductor 4

NC

NC

NC

NC

CR800

Datalogger

NC

NC

NC

NC

C3

G

12V

G

Description

Vibrating Wire +

Vibrating Wire -

Thermistor +

Thermistor -

SDI-12 Communications

Ground

+12VDC Power

Ground

D.1.2 CR800 Wiring (8025-5)

12

CR800

Connections

MUX 1

Interface

Cable

MUX 2

Interface

Cable

CR800 Power

Cable

Description

AG

12V

G

Green & Black Green & Black

Blue Blue

Violet Violet

NC

NC

NC

Analog Ground

12 VDC Output

Ground

C1

C2

C4

*VX1

*SE2

Gray

NC

White

Brown

Red

NC

Gray

White

Brown

Red

NC

NC

NC

NC

NC

Digital I/O Port 1 / RESET

Digital I/O Port 2 / RESET

Digital I/O Port 4 / Clock

Excitation 1 /

Thermistor +

Single Ended Channel 2 /

Thermistor -

+12VDC Power

Power Ground

PWR In +12V

PWR in G

NC

NC

NC

NC

Red

Black

* NOTE: The Thermistor is read using Single Ended Channel 2 and Excited with

VX1 through a bridge completion circuit.

D.1.3 RS-232 Connector Wiring

10-Pin Bendix

A

B

C

D

E

G

Color

White

Green

Orange

Yellow

Blue

Violet

Description

Ground

Transmit

Receive

RTS

CTS

DTR

13

D.1.4 Charger Wiring

Pin Description

A Charger + (14-22 VDC Input)

B

C

Ground

Battery + (12 VDC Output)

D.2 Cables

D.2.1 AC Charger (110VAC/220VAC)

Pin

A

B

Wire Color

Grey

Blue

Violet

Description Condor - Wire Color

Charger + (14-22 VDC Input) Black with White Stripe

Ground Black

D.2.2 External Power Cable

Pin

A

B

C

Description

No Connection

Wire Color

No Connection

Ground Black

Battery + (12 VDC) Red

Clip

No Connection

Black

Red

D.3 Fuses

Fuse

F1

F2

F3

F4

F5

Description

12VDC Auxiliary 1

12VDC Auxiliary 2

12VDC Auxiliary 3

External Battery

Battery

D.4 Multiplexer Connector Wiring

10-Pin

Bendix

A

B

C

D

E

F

G

H

J

K

Color

Brown

Red

Orange

Yellow

Green

Blue

Violet

Grey

White

Black

Description

Vibrating Wire +

Vibrating Wire -

Thermistor +

Thermistor -

Analog Ground

+12 VDC

Ground

MUX Reset

MUX Clock

Analog Ground

14

15

APPENDIX E –LOGGERNET QUICKSTART GUIDE

E.1 Overview

Campbell Scientific’s LoggerNet Software is used to communicate with the Datalogger, program user specific settings and collect Data stored in the Datalogger memory.

LoggerNet is designed to be used with Geokon Micro-1000 and Micro-800 Dataloggers reading Vibrating Wire and MEMS tilt sensors; other configurations and sensor outputs are available upon request. Geokon provides the user with a generic Start Program to simplify acquiring Data without the need to be proficient in Campbell Scientific CRBasic programming code. The Start Program(s) will be pre-configured with a default Scan

Interval and will store Raw Units by default. Each Start Program will have two associated files on the factory supplied USB flash drive. The first is the Main CRBasic program

(.CR1/.CR8) and includes all programming code required to read and store Data according to the Datalogger configuration. The Main CRBasic program does not require modification by the user in most cases. The second file is the Include (.DLD) text file and is used by the Main program to import user specific parameters. The Include file allows program parameters such as the Scan Interval, Zero Readings, Linear Gage Factors, Data

File Header Labels and Temperature Correction factors to be modified by the user.

E.2 Getting Started

E.2.1 Program Files

After installing LoggerNet, the CRBasic program files are located on the Geokon USB

Thumb Drive. The file types are “.DLD” and “.CR1”/“.CR8.”, these files should first be copied to the end users computer in C:\Campbellsci\CRBasicEditor.

E.2.2 Connection Setup

The Launch Menu provides a drop-down list of all the categories on the LoggerNet toolbar. Hovering over a category will display a list of applications related to that category.

With the Launch Menu open, hover over “Main” and press “Setup” from the resulting list of applications.

16

By default, the EZ View of the Setup Screen is displayed. To change the viewing method press the “Std View” icon at the top right of the Setup Screen. This Quick Start will show the “Std View” of the Setup Screen. To add a communication port, press “Add Root” button.

Each Datalogger will communicate via RS232. Select connection type “ComPort”,

“PakBusPort (Other Loggers)”, “CR1000” or “CR800Series” and press “Close”.

17

Select “ComPort” under the “Network Map”, select the communications port to connect to the Datalogger in “ComPort Connection”.

C

ONDITIONAL

N

OTE

: I

T MAY BE NECESSARY TO PRESS

“C

OMMUNICATIONS

E

NABLED

TO

OPEN THE C OMMUNICATIONS P ORT .

COM

NUMBERS VARY WITH COMPUTER

, USB

DEVICES AND SERIAL ADAPTERS

.

R EFER TO THE COMPUTER DEVICE MANAGER IF UNSURE OF WHICH COM NUMBER

TO USE

.

Select “PakBusPort” under the “Network Map”, in “Maximum Baud Rate” for direct connection to the Datalogger select “115200”.

W

HEN FINISHED

,

PRESS THE

“A

PPLY

BUTTON AT THE BOTTOM LEFT OF THE

S

ETUP

S CREEN TO SAVE ALL SETTINGS .

E.2.3 Connecting to the Datalogger

With the LoggerNet Launch Menu open, hover over “Main” and press “Connect”.

18

Select the Datalogger to communicate with under “Stations” and press the “Connect” button.

19

E.3 Modifying the Datalogger Program

Navigate to the Include(.DLD) file on the end user’s computer

C:\Campbellsci\CRBasicEditor. Optional changes to Scan Interval, Zero Readings, Gage

Factors and Alias names can be made by opening the Include(.DLD) file with Notepad.

Each Datalogger configuration has a unique Include(.DLD) file.

W

ARNING

: O

NLY CHANGE VALUES AFTER THE

“=”

SIGN

.

E.3.1 Editing the CRBasic Program

Scan Interval

The number entered in the Scan Interval section determines how often the Datalogger will read the gages and store data. The Scan Interval is in seconds.

Zero Readings & Gage Factors

Default values for Zero Readings are 0 and Linear Gage Factors are 1. The default settings read in Digits for Vibrating Wire sensors and Volts for MEMS tilt sensors. Zero

Readings and Gage Factors can be added if the user requires the Datalogger to store engineering units.

20

Temperature Zero Readings & Thermal Factors

N

OTE

: T

EMPERATURE

Z

ERO AND

T

HERMAL

F

ACTORS ARE USED FOR TEMPERATURE

CORRECTION

.

T

EMPERATURE CORRECTION MAY BE USED TO COMPENSATE FOR CHANGES IN

A GAGE

S READINGS DUE TO TEMPERATURE CHANGE

.

T

EMPERATURE EFFECT ON READINGS

VARIES ON DIFFERENT MODELS OF GAGES AND TEMPERATURE CORRECTION IS OFTEN NOT

REQUIRED

.

D

EPENDING ON THE GAGE MODEL TEMPERATURE CORRECTION MAY NOT BE

AVAILABLE AND SOME GAGE MODELS REQUIRE A DIFFERENT FORMULA TO COMPENSATE .

T

EMPERATURE CORRECTION IS COMMENTED OUT IN THE MAIN PROGRAM FILE BY DEFAULT

.

Default values for Temperature Zero Readings and Thermal Factors are 0. Temperature

Zero Readings and Thermal Factors can be added if the user requires the Datalogger to use temperature compensation.

Navigate to the Main(.CR8/.CR1) file C:\Campbellsci\CRBasicEditor. Open the

Main(.CR8/.CR1) file with notepad and uncomment the line specified in the code for all model gages that temperature correction is required.

21

Output Labels

Default Alias names correspond with the Direct or Multiplexer channel for each specific gage. Alias names get displayed in the Header of the Data file, and can be modified by the user.

W

ARNINGS

: A

LIAS

N

AMES CANNOT BE MORE THAN

35

CHARACTERS LONG AND

MUST ONLY CONTAIN ALPHANUMERIC VALUES AND UNDERSCORES (N O SPACES OR

SYMBOLS

).

S AVE THE I NCLUDE FILE IF MODIFIED .

E.3.2 Uploading Files

The Include.DLD file must be saved when modified. After modification, the Include.DLD must be sent to the Datalogger using the File Control Menu in the LoggerNet Connect

Screen. The Main (.CR8/CR1) program file must be sent to the Datalogger each time the

Include.DLD file is updated.

Sending the Include file (.DLD)

From the “Connect Screen” press “File Control” and press “Send” to transfer the

Include(.DLD) file to the Datalogger.

N OTE : E ACH D ATALOGGER HAS A UNIQUE I NCLUDE (.DLD) AND M AIN (.CR8/.CR1) FILE

Select DLD file type to make the Include(.DLD) file visible in

C:\Campbellsci\CRBasicEditor.

22

Uncheck “Run Now”, the Include(.DLD) file cannot run the Datalogger.

23

Sending the Main program file (.CR8/CR1)

To send the Main(.CR8/CR1) CRBasic Program from the “Connect Screen” press “Send” and select the Main(.CR8/CR1) program file in C:\Campbellsci\CRBasicEditor.

N OTE : E ACH D ATALOGGER HAS A UNIQUE I NCLUDE (.DLD) AND M AIN (.CR8/CR1) FILE

When sending the Main(.CR8/CR1) program file through the “Connect Screen” the program runs automatically.

E.4 Data Handling

E.4.1 Data Collection Configuration

With the Launch Menu open, hover over “Main” and press “Setup” from the resulting list of applications.

24

Select the Datalogger “CR1000”/“CR8000Series”, “Data Files” tab then select “Table1”.

Dataloggers can be renamed by pressing “Rename” button. Renaming the Datalogger affects the name of the Data file. “Output File Name” option allows changing the file name, where to collect and store the Data file. “File Output Option” determines whether new Data collected is appended into one file, overwrites old Data, or creates a new file every time Data is collected.

C

OLLECTED

D

ATA

T

ABLES ARE SIGNIFIED WITH A GREEN CHECK MARK

.

W HEN FINISHED , PRESS THE “A PPLY ” BUTTON AT THE BOTT OM LEFT OF THE S ETUP

S

CREEN TO SAVE ALL SETTINGS

.

E.4.2 Live Monitoring

With the LoggerNet Launch Menu open, hover over “Main” and press “Connect”.

25

Once the program is running, most current readings can be viewed under “Table1” of the

“Table Monitor” and “Num Display”. “Graphs” can also be used to view live and historical Data.

C ONDITIONAL N OTE : I T MAY BE NECESSARY TO START MONITORING BY PRESSING “S TART ”.

E.4.3 Collecting Data

Pressing “Collect Now” collects and stores Data on the computer. After collecting Data a

“Data Collection Results” screen will open.

P

LEASE SEE

L

OGGER

N

ET

M

ANUAL FOR MORE SPECIFIC DETAILS REGARDING USE OF THE

SOFTWARE

.

26

APPENDIX F –8032 MULTIPLEXER Manual

The following Appendix includes excerpts from the Model 8032 Multiplexer manual that apply to the Micro-800. A complete version of the Model 8032 Multiplexer Manual can be found at

WWW.GEOKON.COM

.

THEORY OF OPERATION

The Model 8032 Multiplexer expands the number of channels that can be read by the

MICRO-800 Datalogger or MICRO-1000 Datalogger. Channel switching is accomplished by mechanical relays mounted on the underside of the circuit board and the transducer connections are accomplished by friction locking spring-loaded terminals mounted on the top side of the circuit board.

Two switching configurations are supported, 16 channels of 4 conductors or 32 channels of 2 conductors. For the 8032-C, these configurations are set by a DipSwitch on the top side of the circuit board. A second DipSwitch selects whether the 8032-C is being used with a datalogger or GK-403 Readout Box

To protect against lightning or EMI/RFI induced transients, each channel is protected by an integrated lightning protection system, incorporating 230V tripolar plasma surge arrestors, 150V bipolar plasma surge arrestors, 10uH inductors and 16V transient voltage protection diodes. See Appendix A for complete specifications on these components.

27

Supported switching arrangements:

Multiplexer/Terminal Board

CR800/CR1000

12V

GROUND

RESET

CLOCK

Microcontroller

12V

GROUND

RESET

CLOCK

Relay

Control

31H

32H

32L

31L

S16

Sensor #16

Sensor

Shield

COM HI 1

COM LO 1

COM HI 2

COM LO 2

AG

1H

2H

2L

1L

S1

Sensor #1

Sensor

Shield

Figure 1 - 16 Channel Switching Block Diagram

The 16 channel 4 wire switching configuration is typically used to multiplex 4 wire sensors such as resistance strain gage load cells. It is also used to switch connections for instruments which have more than one sensor integral to them, such as vibrating wire pressure transducers with an integral thermistor for measuring temperature.

Multiplexer/Terminal Board

28

32H

CR800/CR1000

12V

GROUND

RESET

CLOCK

Microcontroller

12V

GROUND

RESET

CLOCK

Relay

Control

32L

S16

Sensor #32

Sensor

Shield

COM HI

COM LO

AG

1H

1L

S1

Sensor #1

Sensor

Shield

Figure 2 - 32 Channel Switching Block Diagram

The 32 channel 2 wire switching configuration is typically used to multiplex 2 wire sensors such as a vibrating wire pressure transducers, thermistors or thermocouples.

The multiplexer is powered by a nominal 12 VDC supply. Two control lines (RESET and CLOCK) determine how channel selection is accomplished. Two schemes are supported - one when connected to the GK-403 Vibrating Wire Readout Box and the other when connected to MICRO-800 or MICRO-1000 dataloggers. See the following sections explaining how each mode operates.

Figure 3 illustrates the DIP switch SW1 position 1 for switching between 16 and 32 channel operation. SW1 switch 1 ON = 32 channel, OFF = 16 channel. In Figure 3, 32 channel mode is chosen:

SW1

ON

OFF

1 2 3 4

Figure 3 - 16 or 32 Channel Selection

29

Figure 4 illustrates the DIP switch SW2 for switching between a GK-403 or Datalogger application. “DATALOGGER”” is the default SW2 position:

SW2

GK-403

DATALOGGER

Figure 4 – GK-403/DATALOGGER Selection

MICRO-1000 / 800 (CR1000 / CR800) Mode of Operation

The MICRO-800 and MICRO-1000 (which respectively utilize a CR800 and CR1000 controller, manufactured by Campbell Scientific, Inc. of Logan, Utah) mode of operation uses two control lines to operate the multiplexer. The RESET line enables the multiplexer and activates the MICRO-800/MICRO-1000 mode of clocking. Pulses received on the CLOCK line sequentially increment the channels while the RESET line is held high. See the timing diagram below;

The CLOCK line sequentially advances the channels beginning with channel 1. Note the timing diagrams below for 16 and 32 channel switching, respectively.

T1

T2

T3

Reset

Clock

No Channel

Selected

Pulse 1 Pulse 2

Channel 1

Selected

Pulse 31 Pulse 32

Channel 16

Selected

No Channel

Selected

Timing: T1 = 50 mSec(min.)

T2 = 2 mSsec(min)

T3 = 2 mSsec(min)

Figure 7 - 16 Channel MICRO-800/MICRO-1000 Channel Selection Timing

T1

T2

T3

Reset

Clock

No Channel

Selected

Pulse 1

Channel 1

Selected

Pulse 2

Channel 2

Selected

Pulse 32

Channel 32

Selected

No Channel

Selected

Timing: T1 = 50 mSec (min)

T2 = 2 mSec (min)

T3 = 2 mSec (min)

Figure 8 - 32 Channel MICRO-800/MICRO-1000 Channel Selection Timing

30

31

WIRING

Actual gage connections to the terminal board will vary depending on the instrument type and cable used. Note the following tables to get the general idea.

Terminal

Board

Vibrating Wire with Thermistor

Resistance Strain

Gage Bridge

Linear Potentiometer

(with Remote Sense)

3H

3L

4H

4L

S2

1H

1L

2H

2L

S1

31H

31L

32H

32L

S16

VW Sensor #1

VW Sensor #1

Thermistor #1

Thermistor #1

Shield Drain Wire from Sensor #1

VW Sensor #2

VW Sensor #2

Thermistor #2

Thermistor #2

Shield Drain Wire from Sensor #2

VW Sensor #16

VW Sensor #16

Thermistor #16

Thermistor #16

Shield Drain Wire from Sensor #16

S+ from Bridge #1

S- from Bridge #1

P+ to Bridge #1

P- to Bridge #1

Shield Drain Wire from Bridge #1

S+ from Bridge #2

S- from Bridge #2

P+ to Bridge #2

P- to Bridge #2

Shield Drain Wire from Bridge #2

S+ from Bridge #16

S- from Bridge #16

P+ to Bridge #16

P- to Bridge #16

Shield Drain Wire from Bridge #16

Table 1 - 16 Channel Multiplexer/Terminal Board Wiring

Excitation Pot #1

Wiper Output Pot #1

Remote Sense Pot #1

Ground Pot #1

Shield Drain Wire from Pot #1

Excitation Pot #2

Wiper Output Pot #2

Remote Sense Pot #2

Ground Pot #2

Shield Drain Wire from Pot #2

Excitation Pot #16

Wiper Output Pot #16

Remote Sense Pot #16

Ground Pot #16

Shield Drain Wire from Pot #16

Terminal

Board

1H

1L

2H

2L

S1

Vibrating Wire Thermistor Thermocouple

3H

3L

4H

4L

S2

31H

31L

32H

32L

S16

VW Sensor #1

VW Sensor #1

VW Sensor #2

VW Sensor #2

Shield Drain Wires from Sensors 1&2

VW Sensor #3

VW Sensor #3

VW Sensor #4

VW Sensor #4

Shield Drain Wires from Sensors 3&4

VW Sensor #31

VW Sensor #31

VW Sensor #32

VW Sensor #32

Shield Drain Wires from Sensors 31&32

Thermistor #1

Thermistor #1

Thermistor #2

Thermistor #2

Shield Drain Wires from Thermistors 1&2

Thermistor #3

Thermistor #3

Thermistor #4

Thermistor #4

Shield Drain Wires from Thermistors 3&4

Thermistor #31

Thermistor #31

Thermistor #32

Thermistor #32

Shield Drain Wires from Thermistors 31&32

Thermocouple #1

Thermocouple #1

Thermocouple #2

Thermocouple #2

Thermocouple #3

Thermocouple #3

Thermocouple #4

Thermocouple #4

Thermocouple #31

Thermocouple #31

Thermocouple #32

Thermocouple #32

Table 2 - 32 Channel Multiplexer/Terminal Board Wiring

5H

5L

6H

6L

S3

3H

3L

4H

4L

S2

1H

1L

2H

2L

S1

7H

7L

8H

8L

S4

32

Figure 10 depicts the terminal board to which gage connections are made. If the terminal board is equipped with manual switches, connectors J1 and J2 will have ribbon cables that are connected to the switch boards.

Terminal Blocks T1/2 to T31/32 are for the gage connections.

J1 J2

T1/2

T3/4

T5/6

T7/8

T9/10 T17/18 T25/26

9H

9L

10H

10L

S5

17H

17L

18H

18L

S9

25H

25L

26H

26L

S13

T11/12 T19/20 T27/28

13H

13L

14H

14L

S7

11H

11L

12H

12L

S6

T13/14

21H

21L

22H

22L

S11

19H

19L

20H

20L

S10

T21/22

29H

29L

30H

30L

S15

27H

27L

28H

28L

S14

T29/30

T15/16 T23/24

15H

15L

16H

16L

S8

23H

23L

24H

24L

S12

31H

31L

32H

32L

S16

P1

GK-403

SW2

ON

SHLD SHLD C1H C1L C2H C2L SHLD +12V GND RESET CLOCK SHLD

DATALOGGER

OFF

SW1

T31/32

J4

Figure 10- Terminal Board Layout

33

TROUBLESHOOTING

Below are some commonly experienced problems along with possible remedial action.

Contact the factory if any problem remains unresolved or additional help is required.

A particular channel on the multiplexer appears to be malfunctioning.

• Check sensor connections on the terminal board. Clean if corrosion exists.

• Try moving the sensor wired to the suspect channel to another channel to verify the malfunctioning of the channel (as opposed to the sensor).

No channels are working.

• Inspect circuit board for shorts, opens, or other damage.

• Is moisture present on circuit board? If so, install desiccant to absorb.

Channel selection appears to be random.

• Has corrosion built up on the circuit board? Clean if necessary.

• Is there a source of electrical noise nearby? Move multiplexer or noise source if possible.

SPECIFICATIONS

A.1 General

Power Requirements: 10-16 VDC (unregulated)

Quiescent Current (MICRO-800/MICRO-1000 mode): 80

µA (16CH mode)

130

µA (32CH mode)

Quiescent Current (GK-403 mode): 12 mA

Channel Activated Current: 30 mA

Control Line Input Impedance: 100 k

Ω (CLOCK), 100 kΩ (RESET)

Control Line Input Levels: TTL or RS-232 (

±9 VDC)

Transient Protection: 16 VDC Transzorbs

Operating Temperature:

−40 to +60° C

A.2 Relays

Type: NAIS TXS2SA-4.5V DPDT non-latching

Power: 11.1 mA @ 5VDC (55.5 mW)

Contact Type: Gold clad silver alloy

On Resistance: 100 m

Coil Resistance: 405

Maximum Switching Power: 30W (resistive)

Maximum Switching Voltage: 110 VDC

Maximum Switching Current: 1 A

Operate Time:

≈5 msec Max.

Release Time:

≈5 msec

Switching Life: 5 x 10 7 operations (mechanical)

2 x 10 5 operations (electrical @ 30W)

Ambient Temperature:

−40 to +70°C

A.3 Tripolar Plasma Surge Arrestor

Nominal DC Breakdown Voltage: 230V

Surge Life: 100 (10/1000 ms pulse @ 200 A)

Maximum Surge Current: 5 kA per side (8/20

µs pulse)

Insulation Resistance: 10

9 Ω

Operating Temperature:

−65 to +125° C

A.4 Bipolar Plasma Surge Arrestor

Nominal DC Breakdown Voltage: 150V

Maximum Surge Current: 1 kA (8/20

µs pulse)

Insulation Resistance: 10

10 Ω

Operating Temperature:

−65 to +125° C

34

35

A.5 Inductor

Rated Current: 4A

Inductance: 10µH (±20%)

D.C.R.: 25m

Ω MAX (at 20°C)

A.6 Transient Voltage Suppressor (Transorb)

Rated Power: 1500W

Peak forward Surge Current: 200A

Reverse Standoff Voltage: 16.0V

A.7 Transducer Connection Maximum Operating Voltage Levels:

Common-mode Voltage/Earth Ground: 16V(max)

Differential-mode Voltage (Channel # ‘H’ – Channel # ‘L’): 16V(max)

A.8 Reset and Clock Maximum Operating Voltage Levels:

Single-ended Control Voltage/System Ground: 16V(max)

36

CONNECTOR AND CABLE WIRING

Description J4 Inside

Color

5

6

7

8

1

2

3

4

Brown

Red

Orange

Yellow

Green

Blue

Purple

Grey

9

10

White

10 Pin

Bendix

K

F

G

H

A

B

C

D

J

E

COM HI 1

COM LO 1

COM HI 2 (16 channel)

COM LO 2 (16 channel)

Analog Ground

+12 Volt Power

Power Ground

RESET (DATALOGGER)

SENSE (GK-403)

CLOCK

No Connection

8032-5 (TAN) Cable

Wire Color

White

White's Black

Red

Red's Black

Shield Drain Wires – all pairs plus overall

Yellow

Yellow's Black

Green

Green's Black

Blue & Blue’s Black (unused)

Table B.1 – J4 (I/O) Connector

P1 Terminal Label Description

1,2

3,4

5,6

7,8

9,10

11,12

13,14

15,16

17,18

19,20

21,22

23,24

SHLD

SHLD

C1H

C1L

C2H

C2L

SHLD

+12V

GND

RESET

CLOCK

SHLD

SHIELD

SHIELD

COM HI 1

COM LO 1

COM HI 2 (16 channel)

COM LO 2 (16 channel)

SHIELD

+12 Volt Power

Power Ground

RESET

CLOCK

SHIELD

Table B.2 – P1 (I/O) Connector

Note: P1 is a “stacking” type connector. Odd number terminals are read left to right on the bottom row. Even numbered terminals are read left to right on the top row.

37

DAISYCHAIN OPERATION

Up to (8) 8032’s may be ”daisychained” together using a common RESET and CLOCK control line. This may be advantageous in situations where either there are not enough control ports available on the Micro-800/MICRO-1000 datalogger for the number of multiplexers desired, or to reduce the number of cables required to implement a large multi-channel system.

SW1 located on the Terminal Block side of the circuit board determines the address of each multiplexer and the corresponding signal channels. As many as 256 2-conductor channels or 128

4-conductor channels may be accessed per RESET line.

2

SW1 Setting

3 4

Channels Accessed

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

OFF 1-32 (32 channel mode) , 1-16 (16 channel mode) DEFAULT MUX1

ON 33-64 (32 channel mode) , 17-32 (16 channel mode) MUX2

OFF 65-96 (32 channel mode) , 33-48 (16 channel mode) MUX3

ON 97-128 (32 channel mode) , 49-64 (16 channel mode) MUX4

OFF 129-160 (32 channel mode) , 65-80 (16 channel mode) MUX5 ON

ON

ON

ON

OFF

OFF

ON

ON

ON 161-192 (32 channel mode) , 81-96 (16 channel mode) MUX6

OFF 193-224 (32 channel mode) , 97-112 (16 channel mode) MUX7

ON 225-256 (32 channel mode) , 113-128 (16 channel mode) MUX8

Table D.1 – Daisychain Operation/Channels Accessed

The following example on the next page is a schematic representations of the daisychain configuration with multiplexers configured for 32 channels. The figure D-1 shows 3 multiplexers sharing the same control ports, and a single cable is used to interconnect them.

VW Gages 1-32

VW Gages 33-64

VW Gages 65-96

C7

Reset

Micro-800/1000

Datalogger

C8

Clock

Reset

H

H

IN

OUT

Clock

J

J

Reset

H

H

IN

OUT

Clock

J

J

Reset

H

IN Clock

J

Multiplexer #1

MUX1

SW1 SETTING:

2 3 4

OFF OFF OFF

Multiplexer #2

MUX2

SW1 SETTING:

2 3 4

OFF OFF ON

Multiplexer #3

MUX3

SW1 SETTING:

2 3 4

OFF ON OFF

Figure D.1: Daisychain Configuration

38

39

MAXIMUM 8032-5 (TAN CABLE) CABLE LENGTHS

The 8032 Multiplexer is a low power device, that when combined with a Micro-800 or Micro-

1000 Datalogger can be physically located at a considerable distance from that Datalogger.

Still, there are limits to the maximum distance – mostly due to the voltage dropped by the 8032-5

MUX cable over its length. Factors such as ambient temperature, number of 8032 Multiplexers

(Daisy-Chain configuration) and system battery voltage need to be considered in determining the maximum 8032-5 cable length.

For a single 8032 Multiplexer under normal operating conditions (System Battery = 12V, ambient temperature = 20°C), the maximum recommended cable length from the Datalogger to the 8032 Multiplexer is 4588 feet (

≈1400m). Figure E.1 displays the maximum recommended cable length for various Datalogger, Battery Voltage and ambient Temperature combinations.

Figure E.1: Recommended Maximum Cable Length