- Entertainment & hobby
- Musical instruments
- Musical Equipment
- Electro-Voice
- Compact Precision CP3000S
- Specification
Electro-Voice Compact Precision CP3000S Specifications
Add to My manuals4 Pages
Electro-Voice CP3000S: Unleash the Power of Audio Excellence
With its exceptional transmission qualities, the Electro-Voice CP3000S power amplifier delivers extraordinary performance. The innovative switching power supply technology and Class H design provide extensive headroom, surpassing the rated nominal output while reducing weight and power dissipation. This amplifier offers reliable operation in demanding environments, with protection against thermal overload, short circuits, and high-frequency/DC occurrences.
advertisement
Technische Informationen
Architects and engineers specifications
BESCHREIBUNG
Die Übertragungseigenschaften der CP-Endstufe sind hervorragend.
Durch eine völlig neu entwickelte Schaltnetzteiltechnologie und die konsequente Anwendung der Class H Technik wird ein großer Headroom weit oberhalb der ausgewiesenen Nennleistung erzielt und gleichzeitig eine deutliche Reduzierung von Gewicht und Verlustleistung erreicht.
Das eingesetzte Schaltnetzteil vereint die Headroom-Vorteile einer
Trafoendstufe mit den Gewichtsvorteilen eines getakteten Netzteils.
Dadurch wird ein ausgezeichnetes Leistungs-Gewicht Verhältnis erreicht.
Bei der Konstruktion wurde besonderes Augenmerk auf einen hohen
Wirkungsgrad und auf Störarmut gelegt. Somit ist auch ein Betrieb in
EMV-kritischer Umgebung problemlos.
Die Endstufenblöcke der CP3000S sind in Class H Technik aufgebaut.
D.h. die Endstufe verfügt über eine extrem schnelle, signalabhängige
Umschaltung der Betriebsspannung, die im Bedarfsfall eine Verdopplung der normalen Versorgungsspannung bewirkt. Im Vergleich zu Class AB
Endstufen wird bei Endstufen mit Class H Technik erheblich weniger
Verlustleistung bei gleicher Ausgangsleistung erzeugt. Weniger
Verlustleistung ist gleichbedeutend mit weniger Abwärme oder besser gesagt mit einer besseren Effizienz bzw. Energiebilanz des Gerätes.
Endstufen in Class H Technik lassen sich daher mit einer entsprechend höheren Packungsdichte im Rack bzw. Gestellschrank verbauen.
Darüber hinaus ist die netzseitige Stromaufnahme wesentlich geringer als im Class AB Betrieb, bei gleicher Ausgangsleistung.
Die Electro-Voice - Endstufen der CP- SERIE erfüllen auch die extremen Anforderungen des harten Tour-Betriebs. Sie sind gegen Überhitzung, Überlast, Kurzschluß sowie Hochfrequenz und
Gleichspannung am Ausgang geschützt. Eine Beschädigung der
Endtransistoren durch Rückeinspeisung elektrischer Energie wird durch die Back-EMF Schutzschaltung verhindert. Beim Softstart werden die
Leistungsausgänge über Relais verzögert zugeschaltet. Zusätzlich verhindert eine Einschaltstrombegrenzung das Ansprechen von
Netzsicherungen.
Höchste Präzision ist auch in der mechanischen Konstruktion und
Verarbeitung gewährleistet. Das robuste Chassis ist besonders verwindungssteif und speziell auf die Belastungen des harten
Tourbetriebs ausgelegt. Die thermische Stabilität wird durch zwei
3-Stufen Lüfter (off/slow/fast) mit sehr niedrigem Geräuschpegel gewährleistet. Die Front-to-Rear Luftführung, erlaubt den Betrieb auch in großen und schmalen Endstufen-Racks. Die Eingänge sind elektronisch symmetrisch auf XLR-Buchsen geführt. Direct-Outs zum Durchschleifen des Signals sind ebenfalls in Form von XLR-Buchsen (male) praktischer
Standard. Über das Input Routing können die Betriebsarten DUAL
(Stereo) oder PARALLEL (Mono) gewählt werden. Außerdem ist der
„Mono Bridged“ –Betrieb über die separate BRIDGED OUT Buchse und den Bridged Mode Umschalter sehr einfach zu realisieren. Auf der
Frontblende sitzen die in dB skalierten Levelregler, die als besonders präzise, bediensichere Rastpotis ausgeführt und zum Schutz vor mechanischer Beschädigung in der Frontblende versenkt sind. Die
CP-Serie bietet intern die Möglichkeit zur Nachrüstung einer analogen
Signalprozessorkarte mit Frequenzweichen- und Filterfunktionen.
Eine schnelle Übersicht über den aktuellen Betriebszustand der Endstufen vermittelt das leicht ablesbare LED-Display. Die
Leistungsausgänge CHANNEL A, CHANNEL B und BRIDGED OUT sind als extrem zuverlässige SPEAKON-Buchsen ausgeführt. Ebenfalls auf der Rückwand befinden sich ein Groundlift-Schalter, der bei Bedarf das Gehäuse der Endstufe von der Schaltungsmasse trennt und somit Brummschleifen verhindern hilft. Alle CP- Endstufen können im
Normalbetrieb an Lasten bis hinab zu 2 Ohm und im Brückenbetrieb bis zu minimal 4 Ohm eingesetzt werden.
DESCRIPTION
The transmission qualities of CP-Series power amps are simply extraordinary. The new switching power supply technology, completely designed from scratch and the consistent use of Class-H technology provide extensive headroom far above the stated nominal output and conspicuous reduction in leakage power at the same time.
The employed switching power supply combines the headroomadvantage of a transformer power amplifier with low weight of a pulsed power supply unit resulting in an improved performance-to-weight ratio.
Special attention had been given to high efficiency and interference immunity already in the designing stage with the result that trouble-free operation of CP-Series power amps is possible even in EMV-critical environments.
The power amplification stages of the CP3000S follow Class-H technology design, i.e. the power amp provides extremely fast, signaldependent operating voltage switching, which, at the time needed, results in doubling the regular supply voltage. Compared to Class-AB power amps, Class-H power amps generate by far less leakage power at identical output. Consequently, reduced leakage power or dissipation is synonymous to less waste heat. In other words: energy is used more efficiently! As a result, installing Class-H power amps within rack shelf systems or cabinets is possible with less space between appliances. In addition to that and despite offering identical output, power consumption is a lot less than in Class-AB operation.
Being protected against thermal and electrical overload, short circuit and the occurrence of HF/DC at the outputs, Electro-Voice CP-SERIES power amps fulfill even the most demanding requirements of Pro-Audio touring applications. Back-EMF-Protection eliminates the risk of the output transistors being damaged by electrical energy back-feed. The power outputs are switched via relay with a time delay during soft-start and an inrush current limiter additionally prevents mains fuses from blowing.
Mechanical construction and workmanship also comply with the highest precision manufacturing standards. The robust chassis is extremely rigid which makes it especially suitable for wearing touring applications. Two three-speed high performance fans (off/slow/fast) guarantee outstanding thermal stability at absolute low running noise.
Front-to-rear ventilation allows trouble-free operation even in smaller amp-racks. The electronically balanced inputs are carried out via XLRtype connectors. Direct-Outs for through connecting the audio signal are also provided via XLRM-type connectors. Input Routing allows selecting DUAL (stereo) or PARALLEL (monaural) operation mode. By means of the separate BRIDGED OUT-connector and a Bridged Modeswitch, switching to “Mono Bridged” operation is truly uncomplicated as well. The recessed mounted dB-scaled level controls ensure reliable protection against mechanical damage. These particularly precise, secure to operate detent-potentiometers are located on the front panel. CP-Series power amps provide the opportunity for retrofitting an internal analogue signal processor board with x-over and filter functions.
The easily readable LED display provides a quick overview of the power amp’s current operational status. The power outputs CHANNEL A,
CHANNEL B and BRIDGED OUT are carried out as extremely durable
SPEAKON-type connectors. Also located on the rear panel is a Groundlift switch, which, when needed, helps eliminating ground-noise loops by separating the power amp’s enclosure from the circuit ground. In normal operation, all CP-Series power amps are capable of driving loads as low as 2ohms. In Mono-Bridged mode the allowable minimum load is
4ohms.
SPECIFICATIONS
- Amplifier at rated conditions, both channels driven, 8
Ω
loads, unless otherwise specified.
Load Impedance
Maximum Midband Output Power
THD = 1%, 1kHz, Dual Channel
Rated Output Power
THD < 0.1%, 20Hz ... 20kHz
Max. Single Channel Output Power
Dynamic-Headroom, IHF-A
Max. Single Channel Output Power
Continuous, 1kHz
Max. Bridged Output Power
THD = 1%, 1kHz
Maximum RMS Voltage Swing
THD = 1%, 1kHz
Power Bandwith
THD = 1%, ref. 1kHz, half power @ 4Ω
Voltage Gain ref. 1kHz
Input Sensitivity at rated output power
THD at rated output power,
MBW = 80kHz, 1kHz
IMD-SMPTE
60Hz, 7kHz
DIM30
3.15kHz, 15kHz
Maximum Input Level
Crosstalk ref. 1kHz, at rated output power
Frequency Response
-1dB, ref. 1kHz
Input Impedance active balanced
Damping Factor
1kHz
Slew Rate
Signal to Noise Ratio, Amplifier
A-weighted
Output Stage Topology
2Ω
1600W
--
2600W
2100W
--
CP3000S
4Ω
1100W
900W
1400W
1300W
3200W
78V
10Hz ... 60kHz
32,0 dB
+5.8 dBu (1.51 V rms)
< 0.05%
< 0.02%
< 0.05%
+22dBu (9.76 Vrms)
< - 80dB
15Hz ... 40kHz
20kΩ
8Ω
600W
450W
720W
660W
2200W
> 300
35 V/ms
107 dB
Class H
Power Requirements
Power Consumption
1/8 maximum output power @ 4Ω
Protection
Cooling
Ambient Temperature Limits
240, 230, 220, 120V or 100V; 50Hz ... 60 Hz (factory configured)
850W
Audio limiters, High temperature, DC, HF, Back-EMF,
Peak current limiters, Inrush current limiters, Turn-on delay
Front-to rear, 3-stage-fans
+5°C ... +40°C ( 40°F ... 105°F)
Safety Class
Dimensions
(W x H x D), mm
Weight
I
483 x 88,1 x 384
8.15 kg (18.0 Ibs)
Remote power On (CPS2.11only) +24Vdc, delay-time selectable
Optional:
Rear-rackmount 15,5“
Rear-rackmount 18“
2-way Crossover, internal filtercard, 24dB, LR
112930 (NRS 90262)
112933 (NRS 90264)
330Hz (NRS 90249), 500Hz (NRS 90250),
800Hz (NRS 90251), 1200Hz (NRS 90252)
Notes:
- Depending on the ambient temperature, the unit might not operate continuously at 2Ω load.
- Due to mains voltage in Japan (100V/50Hz) the values for the maximum output power can be decreased up to 15% (only
100V version)!
BLOCK DIAGRAM
Abmessungen/Dimensions
380
372 5,5
88,1
384
USA Telex Communications Inc., 12000 Portland Ave. South, Burnsville, MN 55337, Phone: +1 952-884-4051, FAX: +1 952-884-0043
Germany EVI AUDIO GmbH, Hirschberger Ring 45, D 94315, Straubing, Germany Phone: 49 9421-706 0, FAX: 49 9421-706 265
Subject to change without prior notice.
www.electrovoice.com
Printed in Germany 10/03/2004 / 363 348
advertisement
Key Features
- High power output: 1500 watts per channel into 4 ohms, 2000 watts per channel into 2 ohms
- Class-H technology for high efficiency and low distortion
- Protection circuits for thermal overload, short circuit, and DC offset