Owner's manual | Vinotemp 1900SS Owner`s manual


Add to my manuals
14 Pages

advertisement

Owner's manual | Vinotemp 1900SS Owner`s manual | Manualzz

WINEMATE Split System

Installation, Operation & Care Manual

VINO1500SS

VINO1900SS

V i i n o t t e m p I n t t e r n a t t i i o n a l l C o r p .

.

w w w .

.

v i i n o t t e m p .

.

c o m

READ AND SAVE THESE INSTRUCTIONS

TABLE OF CONTENTS

Important Safety Information…..........................................2

Feature Description…………………………….……………..3

Installation Instruction………………………………………..5

Use and Temperature Control……………………………….7

Care Guide………………………………………………………8

Troubleshooting……………………………………………….9

Customer Support……………………………………………11

Warranty……………………………………………………….12

Important Safety Information

DO NOT USE A GROUND FAULT INTERRUPTER (GFI).

A DEDICATED 15 AMPCIRCUIT IS HIGHLY RECOMMENDED.

Feature Description

• WineMate split cooling system is designed and used to provide a stable temperature between 52~62 ° F for suitable space at a normal environment.

• The refrigerated space will maintain humidity of 50~70% RH even when the environment becomes dry and humid.

• These temperatures and humilities are optimized for long term storage of wine, fur and tobacco.

• The condensing unit is located away from the wine cellar or other refrigerated enclosure as far as 50 feet, which will bring you extremely quiet operation.

The dimension (in inches) and capacity are specified as follows:

Model

VINO1500

SS

VINO1900

SS

Capacity

(Btu/h)

1500

1900

Unit

Cooler

WM15

SFC

WM19

SFC

Cond

Unit

WM15

SCU

WM19

SCU

Refrigerant

R134a

R134a

Electrical

Unit Cooler/

Cond Unit

115V 60HZ, .7A/

115V 60HZ 3.1A

115V 60HZ 2.2A/

115V 60HZ 3.1A

Weight (lb)

Unit Cooler/

Cond Unit

15/30

20/30

Condensing Unit

WM15SFC Evaporator Unit

VINO19SFC Evaporator Unit

Installation Instruction

Federal law requires that WINEMATE split cooling systems be installed by an EPA certified refrigeration technician.

1. Location

• Place the condensing unit in a properly ventilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling system will not operate properly.

• Leave minimum 3 feet clearance between the exhaust side and the wall.

• Leave minimum 1 foot clearance for the fresh air supply side.

• Condensing unit should be elevated to avoid possible flooding and shaded from direct sun. It should not be exposed to temperatures higher than 125

° F or lower than 20 ° F.

• Air flow from the unit cooler should be unobstructed for at least 1 foot.

2. Refrigeration Installation

Model Liquid Line Diameter

(inch), recommended

VINO1500SS 1/4

VINO1900SS 1/4

Suction Line Diameter

(inch), recommended

3/8

3/8

WINEMATE split system is shipped as components and is ready for use only after a certified refrigeration technician has properly installed and tested the system. Proper installation is critical. WINEMATE can only warrant the quality of the components. The installation and proper operation of the system must be warranted by the installer.

Installation of the system must be done in accordance with all state and local building codes.

The condensing unit and unit cooler are connected by a liquid line and an insulated suction line that are supplied by the installer. These lines must be properly sized for the distance between the two units. After the units and the lines are installed, the system must be pressure tested. If no leaks are found, evacuate and charge system with R134A. Refrigerant amount will vary depending on the length of line set.

3. Electrical Wiring

• We strongly recommend against the use of an extension cord. However, if you still select to use an extension cord, it is absolutely necessary that it is a UL LISTED 3-wire grounding type appliance extension cord. The marked rating of the extension cord should be 115 V, 15 A. or equivalent and not greater than 15ft in length.

VINO1500&1900SS Electrical Wiring Diagram

Use & Temperature Control

1. Temperature Setting

Set the temperature at 55 ° F for the optimum aging of wine

On initial start-up, the time required to reach the desired temperature will vary, depending on the quantity of bottles, temperature setting and surrounding temperature.

Allow 24 hours to stabilize the temperature for each new temperature setting operation

2. Use of the thermostat

Turn clockwise to decrease temperature.

Turn counter clockwise to increase temperature.

Care Guide

In general, always unplug system or disconnect power while doing care.

1. Coil Cleaning

• Clean the condenser coil regularly. Coil may need to be cleaned at least every 6 months.

• Unplug the system or disconnect power.

• Use a vacuum cleaner with an extended attachment to clean the coil

2. Moisture Removing when it is dusty or dirty.

• Plug cooling system or reconnect power.

• Remove the extra condensate if it is accumulated in the wine cellar at high ambient temperature and humidity.

Troubleshooting

This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration service person, not is it comprehensive

Troubleshooting Chart

Response

1. Unit not running a. Power cord unplugged b. No power to unit a. Check for power cord plug b. Check power at receptacle & fuses e. Incorrect or loose wirings. f. Improper area to be cooled. d. Contact an authorized electrician e. Check all wirings and connections g. Running light blinking g. Call service for failed components

2. Compressor stopping and starting but short running time a. Incorrect temperature setting a. Set 55 to 60

°

F b. Check for voltage c. Check thermistor by placing it in ice water and measuring resistance d. Check compressor windings, start relay and overload protector. e. Check for condenser fan g. Overcharge of refrigerant h. Discharge or suction pressure too high

4. Compressor running but fan not running a. Fan blade bond b. Incorrect or loose wirings g. Call service for removing refrigerant h. Call service for OEM information

3. Fan motor running but compressor not running a. Incorrect power supply b. Incorrect or loose wirings d. Liquid refrigerant in the compressor a. Check for proper voltage b. Check all wirings and connections c. Check start relay, start capacitor, overload protector, compressor. d. Call service for OEM information. a. Check for proper clearance b. Check all wirings c. Call service for checking open or shorted windings

5. No cooling but compressor and fan running a. Evaporator airflow restriction a. Check for airflow through evaporator b. Check for loss of refrigerant c. Call service for checking restrictions

6. Temperature too high or unit running too long a. Improper evaporator or condenser a. Check for air restrictions airflow c. Defrost and reset temperature d. Check for both fans e. Check for gasket and door opening f. Check for excessive load incorrect installation

h. Operating 60 Hz unit at 50Hz j. Undercharge or overcharge g. Check power supply h. Use proper 60 Hz i. Call service for checking loss of refrigerant or restrictions j. Call service to add or remove refrigerant

7. House circuit tripping a. Incorrect fuse or breaker a. Check for proper fuse or breaker b. Check for wirings and connections c. Call service

8. Noisy operation a. Mounting area not firm a. Add support to improve installation b. Check fan blades, bearings, cabinet washers, tubing contact and loose c. Compressor overloaded due to high ambient temperatures or airflow restriction screws. c. Check for airflow blockage d. Call service for checking Internal loose, inadequate lubrication and incorrect wirings

Customer Support

If you still have problems, please contact us at:

Vinotemp International

17631 South Susana Road

Rancho Dominguez, CA 90221

Tel: (310) 886-3332

Fax: (310) 886-3310

Email: [email protected]

Warranty

Thank you for choosing a Vinotemp wine cellar.

Please enter the complete model and serial numbers in the space provided:

Model_________________________________________________________

Serial No.______________________________________________________

Attach your purchase receipt to this owner’s manual.

1. Limited Warranty

VINOTEMP warrants its products, parts only, to be free from defects due to workmanship or materials under normal use and service for twelve months after the initial sale. If the product is defective due to workmanship or materials, is removed within twelve months of the initial sale and is returned to VINOTEMP, in the original shipping carton, shipping prepaid, VINOTEMP will at its option, repair or replace the product free of charge.

This warranty constitutes the entire warranty of the VINOTEMP with respect to its products and is in lieu of all other warranties, express or implied, including any of fitness for a particular purpose. In no event shall VINOTEMP be responsible for any consequential damages what is so ever. Any modification of VINOTEMP products shall void this warranty.

Service under Warranty

This service is provided to customers within the continental UNITED STATES only. VINOTEMP cooling units are warranted to produce the stated number of

BTU/H. While every effort has been made to provide accurate guidelines,

VINOTEMP can not warranty its units to cool a particular enclosure.

In case of failure, VINOTEMP cooling units must be repaired by the factory or its authorized agent. Repairs or modifications made by anyone else will void the warranty.

Should a VINOTEMP cooling unit fail, contact the dealer for instructions. Do not return the unit to the factory without authorization from VINOTEMP. If the unit requires repair, re-pack it in the original shipping carton and return it to the factory, shipping prepaid. VINOTEMP will not accept COD shipments. If the unit is determined to be faulty and is within the twelve month warranty period

VINOTEMP will, at its discretion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.

2. Limitation of Implied Warranty

VINOTEMP’S SOLE LIABILITY FOR ANY DEFECTIVE PRODUCT IS LIMITED

TO, AT OUR OPTION, REPAIRING OR REPLACING OF UNIT.

VINOTEMP SHALL NOT BE LIABLE FOR:

DAMAGE TO OTHER PROPERTY CAUSED BY ANY DEFECTS IN THE UNIT,

DAMAGES BASED UPON INCONVENIENCE, LOSS OF USE OF THE UNIT,

LOSS OF TIME OR COMMERCIAL LOSS, ANY OUTER DAMAGES,

WHETHER INCIDENTAL, CONSEQUENTIAL OR OTHERWISE.

THIS WARRANTY IS EXCLUSIBE AND IS IN LIEU OF ALL OTHER

WARRANTIES, EXPRESSED OR INPLIED, INCLUDING BUT NOT LIMITED

TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE.

While great effort has been made to provide accurate guidelines VINOTEMP cannot warrant its units to properly cool a particular enclosure. Customers are cautioned that enclosure construction, unit location and many other factors can affect the operation and performance of the unit. There for suitability of the unit for a specific enclosure or application must be determined by the customer and cannot be warranted by VINOTEMP.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement