LRG-55 | Chauvet Scorpion Dual User manual


Add to my manuals
19 Pages

advertisement

LRG-55 | Chauvet Scorpion Dual User manual | Manualzz

LRG-55

Scorpion™ 55 RG

USER MANUAL

CHAUVET, 3000 N 29 th

Ct, Hollywood, FL 33020 U.S.A

(800) 762-1084 – (954) 929-1115

FAX (954) 929-5560 www.chauvetlighting.com

T

ABLE OF

C

ONTENT

BEFORE YOU BEGIN .................................................................................................................................... 3

W HAT IS INCLUDED ......................................................................................................................................... 3

U NPACKING I NSTRUCTIONS ............................................................................................................................. 3

AC P OWER ................................................................................................................................................... 3

S AFETY I NSTRUCTIONS ................................................................................................................................... 4

INTRODUCTION ............................................................................................................................................ 5

F EATURES ..................................................................................................................................................... 5

DMX C HANNEL S UMMARY .............................................................................................................................. 5

P RODUCT O VERVIEW ..................................................................................................................................... 6

G ENERAL I NSTRUCTIONS ................................................................................................................................ 7

COMPLIANCE STATEMENT ......................................................................................................................... 8

L ASER S AFETY AND C OMPLIANCE I NFORMATION ............................................................................................... 8

P

ROPER

U

SAGE

............................................................................................................................................ 9

CONTROL & FUNCTION ............................................................................................................................... 9

D

IPSWITCH

C

HART

......................................................................................................................................... 9

DMX M ODE .................................................................................................................................................10

Setting the starting address ...............................................................................................................10

O PERATION ..................................................................................................................................................11

Stand-Alone Operation (Sound_Active, Auto Mode): .............................................................................11

Master-Slave Operation (Master_Sound, Master_Auto): .......................................................................11

Universal DMX Control (DMX Mode): ....................................................................................................12

T ROUBLE S HOOTING .....................................................................................................................................12

APPENDIX.....................................................................................................................................................13

DMX P RIMER ...............................................................................................................................................13

Fixture Linking....................................................................................................................................13

DMX Q UICK R EFERENCE C HART ...................................................................................................................14

DMX C HANNEL V ALUES ................................................................................................................................15

T ROUBLE S HOOTING .....................................................................................................................................15

D YNAMIC P ATTERNS & DMX V ALUES .............................................................................................................16

S TATIC P ATTERNS & DMX V ALUES ................................................................................................................17

G ENERAL M AINTENANCE ...............................................................................................................................18

R ETURNS P ROCEDURE ..................................................................................................................................18

C LAIMS ........................................................................................................................................................18

T ECHNICAL S PECIFICATIONS ..........................................................................................................................19

T ECHNICAL S UPPORT ....................................................................................................................................19

LRG-55 User Manual 2

11/14/2007/18:46

B

EFORE

Y

OU

B

EGIN

What is included

¾ 1 x Scorpion™ 55 RG

Unpacking Instructions

Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling. Save the carton and all packing materials. In the event that a fixture must be returned to the factory, it is important that the fixture be returned in the original factory box and packing.

AC Power

Warning!

To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before applying power to a fixture, check that the source voltage matches the fixture’s requirement.

Figure 1 - AC Voltage Switch

Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use.

Verify that the power select switch on your unit matches the line voltage applied. All fixtures must be connected to circuits with a suitable Earth Ground.

Not all fixtures have a voltage select switch. Please be sure to connect to the proper voltage.

LRG-55 User Manual 3

11/14/2007/18:46

Introduction

Safety Instructions

Caution!

Please read these instructions carefully, which includes important information about the installation, usage and maintenance?

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet.

Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture.

This product is intended for indoor use only!

To prevent risk of fire or shock, do not expose fixture to rain or moisture. Make sure there are no flammable materials close to the unit while operating.

The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.

Always disconnect from power source before servicing or replacing lamp or fuse and be sure to replace with same lamp source.

Secure fixture to fastening device using a safety chain. Never carry the fixture solely by its head. Use its carrying handles.

Maximum ambient temperature is Ta: 35 °. Do not operate fixture at temperatures higher than this.

In the event of serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. Always use the same type spare parts.

Don’t connect the device to a dimmer pack.

Make sure power cord is never crimped or damaged.

Never disconnect power cord by pulling or tugging on the cord.

Avoid direct eye exposure to lamp while it is on.

There are no user serviceable parts inside the unit. Do not open the housing or attempt any repairs yourself. In the unlikely event your unit may require service, please contact CHAUVET.

LRG-55 User Manual 4

11/14/2007/18:46

I

NTRODUCTION

You may notice that both the red and green beams coming out of the projector are larger than the

4.95mW projectors. There is a very distinct reason for this. Unlike 4.95mW projectors the output of the CHAUVET laser projectors with Fatbeam™ technology inside outputs <20mW for each beam.

Normally outputs greater than 4.95mW require a variance from the FDA. This product has been designed to meet a special classification of ClassIIIR. Under this classification with the Fatbeam™ technology the acceptable energy levels (AEL) have been met. Therefore the maximum potential exposure to the unaided eye is less than 4.95mW for a static beam. Additionally the (MPE) or

Maximum Permissible Exposure with this product is below acceptable levels for human ocular or tissue exposure.

Features

CONTROL FEATURES

8-channel DMX controlled green and red laser

41 Dynamic, 50 Static patterns, laser off & sound active mode

- Scan and speed adjustment yields 500 laser effects

- 44 patterns in sound active mode

- 48 patterns in auto mode

X and Y position adjustment of laser effect

- X moves lasers in opposite movements

- Y moves lasers in unison

Dynamic Scan speed adjust

Dynamic pattern speed adjust

Static pattern size adjust

Laser color selection; red, green or both red & green

FEATURES

Dual 10mW Fatbeam™ Laser technology produces 10-14mm beam which complies with IEC

Safety Standards under ClassIIIR

Operating modes; Auto, Sound

Active, Master/Slave & DMX

Safety cover for scanner mirrors

Sound sensitivity control

Sound activated via DMX

Scanning motors (micro stepping)

DMX Channel Summary

6

7

8

4

5

C HANNEL F UNCTION

1 Mode

2

3

Pattern Selection

X Position

Y Position

Scan speed

Dynamic Pattern select

Static Pattern size

Color

5 LRG-55 User Manual

11/14/2007/18:46

Product Overview

Dipswitch settings for DMX addressing & other functions

DANGER: Laser Radiation emitted from this aperture.

Before connecting the unit to AC power, make certain that the front aperture is pointed away from you or others.

Sound

Sensitivity

Knob

Power Switch

Fan

DMX connectors

Switch selectable power

AC Power Input

LRG-55 User Manual 6

11/14/2007/18:46

AC Power Connection:

The unit is supplied with a power plug appropriate to its voltage and destination. Should any other connections be required they must be carried out with the following configuration.

Earth = Green/Yellow cable

Neutral = Blue cable

Live = Brown cable

General Instructions

Please read carefully and thoroughly the contents of this manual before operating the Laser system.

These instructions contain important safety information regarding the use and maintenance of this system. Please keep this manual for future reference.

Every unit has been thoroughly tested and has been shipped in perfect operating condition.

Check the shipping carton for damage that may have occurred during shipping.

If the carton appears to be damaged carefully inspect your unit for any damage.

Be sure all equipment necessary to operate the system gas arrived intact.

In the event that damage has been found or parts are missing, please contact CHAUVET customer support for further instructions.

Please do not return the unit to your dealer without first contacting CHAUVET customer support.

Notice!

1) Please insure the power supply has good connect with ground before operating the unit in order to prevent electrical shock.

2) This system is intended to only be operated indoors. Avoid any direct contact with water, and make certain the unit is firmly mounted.

3) Ensure the operating temperature is within the specified normal range of 18~30

0

C.

4) Prolonged operation shortens the life of the laser device.

5) The system over a long period of time may build up dust and other contaminants on the scanner optics and or the aperture window.

6) Do not remove any of the laser safety warning labels, manufacturing label, and warranty labels.

If the warranty labels are broken the warranty will be voided.

7) Please contact us if you experience any problems with this unit.

8) NO USER SERVICABLE PARTS INSIDE:

Warranty Void if Warranty Seals are missing or appear tampered with.

9) Please do not discard the shipping materials. In the event you must return the unit please do so in the original factory packaging to avoid further damage.

LRG-55 User Manual 7

11/14/2007/18:46

C

OMPLIANCE

S

TATEMENT

Your LRG-55 complies with FDA/CDRH 21CFR1040 and Laser Notice 50 as well as IEC 60825-

1:2003. Due to a unique optic design, this product does not exceed output powers that exceed its classification and output levels government agencies have determined to be appropriate for the products function.

Laser Safety and Compliance Information

This product is manufactured to comply with the IEC 60825-1 and in accordance with U.S. Food and

Drug Administrations (FDA) Standards listed under FDA Document 21 CFR 1040 and subsequent laser notices.

Product Classification and Manufacturing Label Identification

Laser Classification

Laser Medium

Cooling

Output

Class IIIa

DPSS YVO4 532nm / Diode 650nm

Fan Cooled

Dual <20mW

Beam Diameter at aperture 10 – 14mm

Beam Divergence

Radiant Exposure at

Aperture

Optically adjusted for compliance

<4.95mW (7mm Human Limiting Aperture)

There is only one laser aperture on this product.

CAUTION: AVOID EXPOSURE TO BEAM: Avoid direct eye contact with laser light. Never intentionally expose your eyes or others to direct laser radiation.

Non-Interlocked Housing Warning Labels. This unit contains an embedded laser device that exceeds the output of the intended class internally. Exposure to unsafe levels of laser radiation when opened.

Additionally there are no user

serviceable parts inside. Tampering or removing warranty seals will void your products limited warranty.

CAUTION:

The use of corrective eye wear or optics for viewing at distances such as telescopes or binoculars within a distance of 100mm may pose an eye hazard.

LRG-55 User Manual 8

11/14/2007/18:46

Proper Usage

This unit has been designed to be hung. It is recommended that, for safety purposes, your lighting effect are properly mounted using a suitable hanging clamp and safety cable.

CHAUVET offers a range of items, which are ideal for safe mounting.

It is the responsibility of the manufacturer to provide useful instruction on the proper use of this product. According to FDA Regulations you should operate the product in the fashion illustrated below.

CAUTION: Use of controls, adjustments, or performance of procedures other than what is specified herein may result in hazardous radiation exposure

C

ONTROL

& F

UNCTION

This unit uses dipswitches to assign a units function, DMX address and DMX MODE of function. Each dipswitch represents a binary value.

Dipswitch Chart

DIPSWITCH CHART

0=OFF 1=ON X=0FF or ON

FUNCTION

1 2 3 4 5 6 7 8 9 10 11 12

X X X X X X X X X 0 0 0

X X X X X X X X X 0 0 1

X X X X X X X X X 0 1 0 MASTER_SOUND

X X X X X X X X X 0 1 1

X X X X X X X X X 1 0 0

MASTER_AUTO

SLAVE

SET DMX ADDRESS 1 0 1 DMX MODE

X X X X X X X X X 1 1 0

Function chart

Dipswitches #10,#11,and #12 is set system function, from #1 to #9 is set

DMX512 address in DMX MODE.

LRG-55 User Manual 9

11/14/2007/18:46

DMX Mode

In this mode you will be able to control each individual trait of the fixture independently. The LRG-55 occupies 8 channels of DMX control. For detailed listing of the DMX channel values refer to the

Appendix section.

S E T T I N G T H E S T A R T I N G A D D R E S S

This DMX mode enables the use of a universal DMX controller device. Each fixture requires a "start address" from 1 to 511. A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address. For example, a fixture that occupies or uses 6 channels of DMX and was addressed to start on DMX channel 100, would read data from channels: 100, 101,

102, 103, 104, and 105. Choose start addresses so that the channels used do not overlap and notate the start address selected for future reference.

If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping to the Appendix Section and read the heading “DMX Primer”. It contains very useful information that will help you understand its use.

Set the start address using the group of DIP switches located usually on bottom of the fixture. Each dip switch has an associated value. Adding the value of each switch in the ON position will provide the start address. Determining which switches to toggle ON given a specific start address can be accomplished in the following manner. By subtracting the largest switch value possible from the selected start address which does not cause a negative number.

E

XAMPLE

S

TARTING

A

DDRESS

Address 10

Pin # 4 = 8

Pin # 2 = 2

Total = 10

ON

OFF

1 2 3 4 5 6 7 8

DIP

9 10 11 12

Address 24

Pin # 5 = 16

Pin # 4 = 8

ON

OFF

1 2 3 4 5 6 7 8

DIP

9 10 11 12

Resolving address using simple math.

Address 233

233 – (128) = 105, Turn ON Dip # 8

105 – (64) = 41, Turn ON Dip # 7

41 – (32) = 9, Turn ON Dip # 6

9 – (8) = 1, Turn ON Dip # 4

1 – (1) = 0, Turn ON Dip # 1

You will most likely use the first available number which maybe number

1. This number was selected for example purposes.

D IP S WITCH (DMX V ALUE )

5

6

7

8

9

1

2

3

4

1

2

4

8

16

32

64

128

256

LRG-55 User Manual 10

11/14/2007/18:46

Operation

Stand-Alone Operation (Sound_Active, Auto Mode):

This mode allows a single unit to run to the beat of the music, or the unit will auto change in Auto

Mode.

1) Set dipswitches position to Sound Active or Auto Mode.

Mode Dipswitches

Sound Active

Auto Mode

10 = Off, 11 = Off, 12 = Off

10 = Off, 11 = Off, 12 = On

2) The unit will react to the low frequencies of music via the internal microphone in Sound Active mode, or the unit will auto change in Auto Mode.

3) Use the audio sensitivity knob on the back of the unit to make the unit more or less sensitive in

Sound Active.

N: SOUND/AUDIO 2: SOUND/AUTO 1: SOUND/AUTO

Master-Slave Operation (Master_Sound, Master_Auto):

This mode will allow you to link up to 32 units together without controller.

1) Use standard XLR DMX cable to daisy chain your units together via the XLR connector on the rear of the units. For longer cable runs we suggest a terminator on the last fixture.

2) Choose a unit to function as Master mode. Turn dipswitches to the Master position on the unit.

The unit must be first unit in line. Then simply chain the units together using XLR cable.

Mode

Master Sound

Master Auto

Dipswitches

10 = Off, 11 = On, 12 = Off

10 = Off, 11 = On, 12 = On

3) Turn switch to the Slave position on the slave units, and they will react the same as the Master.

Mode Dipswitches

Slave 10 = On, 11 = Off, 12 = Off

OUT

1: MASTER

POWER

IN

2: SLAVE N: SLAVE

LRG-55 User Manual 11

11/14/2007/18:46

Universal DMX Control (DMX Mode):

This mode allows you to use a universal DMX-512 controller to control lasers operation and effects.

1) To control your fixture in DMX Mode use standard XLR DMX cable to daisy chain your units together via the XLR connector on the rear of the units. For long cable runs we suggest a terminator at the last fixture.

Mode Dipswitches

DMX mode 10 = On, 11 = Off, 12 = On

2) Assign a DMX address to the unit by following the dipswitch chart.

3) Use DMX controller to control your units.

DMX-512 OUT

1: DMX

IN

2: DMX

Note! System doesn’t use DMX controller in Master-Slave Mode.

System may not set to two Master units in Master-Slave Mode.

N: DMX

POWER

Trouble Shooting

1) If the power supply indicator does not light up and the laser does not work, please check if the power supply and the corresponding parts have the right input electric current.

2) If it is in stand-alone mode operation, the power supply indicator is lit and the laser is not working, please check if the operation system is set up in Master/Slave mode.

3) If it is in Master/Slave mode, Slave mode is exceptional, please check as below:

A. Make sure to set up Master mode for just one unit and the others are set in slave mode.

B. Make sure to control the unit with DMX controller.

C. Make sure to take a good quality power cord and connection.

4) If the unit is in DMX mode, the laser cannot be controlled by the DMX controller, and the DMX signal indicator is not illuminated please check as below:

A. Make sure to set up the DMX mode.

B. Make sure to have a good connection.

5) If it is in DMX mode, the laser is cannot be controlled by the DMX controller but the DMX signal indicator flashes, please make sure the DMX controller and the laser have the same DMX

Address.

6) If the no laser outputs from the projector please restart the AC power by turning off the AC switch and leaving off for 15 seconds and then turning the switch back to the on position.

7) If the test pattern is not in the proper position restart the AC power by turning off the AC switch and leaving off for 15 seconds and then turning the switch back to the on position.

After trying the above solution you still have a problem, please contact CHAUVET.

LRG-55 User Manual 12

11/14/2007/18:46

A

PPENDIX

DMX Primer

There are 512 channels in a DMX-512 connection. Channels may be assigned in any manner. A fixture capable of receiving DMX 512 will require one or a number of sequential channels. The user must assign a starting address on the fixture that indicates the first channel reserved in the controller.

There are many different types of DMX controllable fixtures and they all may vary in the total number of channels required. Choosing a start address should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the same type using the same starting address as long as the intended result is that of unison movement or operation. In other words, the fixtures will be slaved together and all respond exactly the same.

Note!

DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are connected is not important and has no effect on how a controller communicates to each fixture. Use an order that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data Negative (S-) and pin 3 is Data positive (S+). CHAUVET carries 3-pin XLR DMX compliant cables, DMX-10 (33’), DMX-4.5 (15’) and DMX-1.5 (5’)

F I X T U R E L I N K I N G

Figure 2 - DMX connector configuration

COMMON

1

3

2

Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the last fixture.

INPUT

1

3

2

DMX +

DMX -

1

2

3 OUTPUT

Termination reduces signal errors and to avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator.

If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M.

The chart below details a proper cable conversion:

3 P IN TO 5 P IN C ONVERSION C HART

C ONDUCTOR 3 Pin Female (output) 5 Pin Male (Input)

G ROUND /S HIELD

D ATA ( ) SIGNAL

D ATA ( + ) SIGNAL

D O NOT USE

D O NOT USE

Pin 1

Pin 2

Pin 3

Pin 1

Pin 2

Pin 3

Do not use

Do not use

LRG-55 User Manual 13

11/14/2007/18:46

DMX Quick Reference Chart

DMX Address Quick Reference Chart

Dip Switch Position

DMX DIP SWITCH

SET

#9 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1

X=OFF or ON

#1 #2 #3 #4 #5

#6 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

0 0 0 0 0 32 160 192 224 256 288 320 352 384 416 448 480

1 0 0 0 0 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481

0 1 0 0 0 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482

1 1 0 0 0 3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483

0 0 1 0 0 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484

1 0 1 0 0 5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485

0 1 1 0 0 6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486

1 1 1 0 0 7 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487

0 0 0 1 0 8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488

1 0 0 1 0 9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489

0 1 0 1 0 10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490

1 1 0 1 0 11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491

0 0 1 1 0 12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492

1 0 1 1 0 13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493

0 1 1 1 0 14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494

1 1 1 1 0 15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495

0 0 0 0 1 16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496

1 0 0 0 1 17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497

0 1 0 0 1 18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498

1 1 0 0 1 19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499

0 0 1 0 1 20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500

1 0 1 0 1 21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501

0 1 1 0 1

1 1 1 0 1

0 0 0 1 1

1 0 0 1 1

0 1 0 1 1

1 1 0 1 1

0 0 1 1 1

1 0 1 1 1

22 54 86 118

23 55 87 119

24 56 88 120

25 57 89 121

26 58 90 122

27 59 91 123

28 60 92 124

29 61 93 125

150

151

152

153

154

155

156

157

182

183

184

185

186

187

188

189

214

215

216

217

218

219

220

221

246

247

248

249

250

251

252

253

278

279

280

281

282

283

284

285

310

311

312

313

314

315

316

317

342

343

344

345

346

347

348

349

374

375

376

377

378

379

380

381

406 438 470

407 439 471

408 440 472

409 441 473

410 442 474

411 443 475

412 444 476

413 445 477

502

503

504

505

506

507

508

509

0 1 1 1 1 30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510

1 1 1 1 1 31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511

Dip Switch Position DMX Address

LRG-55 User Manual 14

11/14/2007/18:46

DMX Channel Values

Channel Value Function

1

2

3

4

5

6

7

8

000 Ù 010

011

Ù 120

121

251

000

000

Ù 250

Ù 255

Ù 255

Ù 255

000

Ù 255

000 Ù 255

000 Ù 255

000 Ù 255

000 Ù 100

101 Ù 200

201 Ù 255

Mode

Laser off

Dynamic Patterns

Static Patterns

Sound Active Mode

Pattern Selection

Static Patterns – Dynamic Patterns

X Position

Left > Right

Y Position

Top > Bottom

Scan Speed

Fast > Slow

Dynamic Pattern Speed Control

Fast > Slow / See page 16

Static Pattern Size Control

Small > Big / See page 17

Color

Green & Red ON

Green

Red

NOTES Some Static patterns can adjust both in size and position.

CAUTION: Use of controls, adjustments, or performance of procedures other than what is specified herein may result in hazardous radiation exposure

Trouble Shooting

1) If the power supply indicator does not light up and the laser does not work, please check if the power supply and the corresponding parts have the right input electric current.

2) If it is in stand-alone mode operation, the power supply indicator is lit and the laser is not working, please check if the operation system is set up in Master/Slave mode.

3) If it is in Master/Slave mode, Slave mode is exceptional, please check as below:

A. Make sure to set up Master mode for just one unit and the others are set in slave mode.

B. Make sure to control the unit with DMX controller.

C. Make sure to take a good quality power cord and connection.

4) If the unit is in DMX mode, the laser cannot be controlled by the DMX controller, and the DMX signal indicator is not illuminated please check as below:

A. Make sure to set up the DMX mode.

B. Make sure to have a good connection.

5) If it is in DMX mode, the laser is cannot be controlled by the DMX controller but the DMX signal indicator flashes, please make sure the DMX controller and the laser have the same DMX

Address.

6) If the no laser outputs from the projector please restart the AC power by turning off the AC switch and leaving off for 15 seconds and then turning the switch back to the on position.

7) If the test pattern is not in the proper position restart the AC power by turning off the AC switch and leaving off for 15 seconds and then turning the switch back to the on position.

After trying the above solution you still have a problem, please contact CHAUVET.

LRG-55 User Manual 15

11/14/2007/18:46

Dynamic Patterns & DMX Values

LRG-55 User Manual 16

11/14/2007/18:46

Static Patterns & DMX Values

LRG-55 User Manual

General Maintenance

To maintain optimum performance and minimize wear fixtures should be cleaned frequently. Usage and environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned at least twice a month. Dust build up reduces light output performance and can cause overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance.

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on external vents and internal components. Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint.

Returns Procedure

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued.

Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the customer’s responsibility. CHAUVET reserves the right to use its own discretion to repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use.

Claims

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is damaged due to shipping. Any other claim for items such as missing component/part, damage not related to shipping, and concealed damage, must be made within seven (7) days of receiving merchandise.

LRG-55 User Manual 18

11/14/2007/18:46

Technical Specifications

WEIGHT & DIMENSIONS

Length......................................................................................................................... 256 mm (10.08 in)

Width .......................................................................................................................... 270 mm (10.63 in)

Height ........................................................................................................................... 130 mm (5.12 in)

Weight ......................................................................................................................... 4.25 Kg (9.37 lbs)

POWER

Switch-selectable power settings .............................................................. 120V 60Hz AC or 230V 50Hz

Fuse............................................................................................................................................ 2A 250V

Current draw ........................................................................ (peak 25W @ 120V), (peak 25W @ 230V)

LASER

Rated power ..................................................................................................................................... 20W

Diode ................................................................................................................... 1 x 10mW green laser

Diode ........................................................................................................................ 1 x 10mW red laser

Wavelength.................................................................................................................. 532 nm & 650 nm

Pan ..................................................................................................................................................... 97°

Tilt....................................................................................................................................................... 47°

Part No ............................................................................................................................... 10mW Green

Laser Type...................................................................................................................................... DPSS

Laser Output........................................................................................................................Dual <20mW

Cooling .................................................................................................................................. Fan Cooled

CONTROL & PROGRAMMING

Data input ................................................................................................ locking 3-pin XLR male socket

Data output ........................................................................................... locking 3-pin XLR female socket

Data pin configuration ..............................................................................pin 1 shield, pin 2 (-), pin 3 (+)

Protocols........................................................................................................................ DMX-512 USITT

DMX Channels .......................................................................................................................................8

ORDERING INFORMATION

Scorpion™ 55 RG ....................................................................................................................... LRG-55

Technical Support

Address: Service Dept.

3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)

Support (Email): [email protected]

Telephone: (954) 929-1115 - (Press 4)

Fax: (954) 929-5560 - (Attention: Service)

Website: http://www.chauvetlighting.com